Loading...
HomeMy WebLinkAboutWA-14-19City of Wheat Ridge Municipal Building 7500 W 29"' Ave, Wheat Ridge, CO 80033-8001 P: 303,235.2846 F: 303.235.2857 Tyler Downs Wazee Partners, LLC 2300 15th Street, Suite 425 Denver, CO 80202 MEMEREM Please allow this letter to serve as confirmation that the Wheat Ridge Town Center North Apartments — Site Plan Amendment No. I has been gpproved, The modified site plan has been reviewed and approved by the Public Works and Community Development Departments. The shift in the buildinj did rwuire a variance reliati -a- Please feel free to be in touch with any additional questions. 9MEM www-ci.wheatridge.co.us AC Lauren E. Mikulak, AICP Senior Planner www-ci.wheatridge.co.us WHEREAS, an application for a variance was submitted for the property located at 7340 W. 44th Avenue referenced as Case No. WA- 14-19 / TCN; and WHEREAS, City staff found basis for approval of the variance, relying on criteria listed in Section 26-115 of the Wheat Ridge Code of Laws and on information submitted in the case file; and WHEREAS, the Community Development Department has properly notified pursuant to Section 26-109 of the Wheat Ridge Code of Laws; and WHEREAS, there were no registered objections regarding the application; NOW THEREFORE, be it hereby resolved that a 2-foot variance from the 20-foot accessible aisle length standard to allow an 18-foot accessible parking space and access aisle on property in the Mixed Use-Commercial (MU-C) zone district (Case No. WA- 14-19 / TCN), is granted for property located at 7340 W. 44' Avenue, based on the following findings of fact: With the following conditions I . The revised site plan sheet shall be appended to the plan set associated with the approved building permit. 2. Prior to issuance of the Certificate of Occupancy, the subdivision plat shall be amended to reflect the updated location of the detention easement. t J_ ""`- 1 - 6, enne Johnston Date 2 J sto Cp C Deve pment Director ► 1 Ci r wh 4 TO: CASE MANAGER: CASE NO. & NAME ACTION REQUESTED: ty of °at - I�id�ge CITY OF WHEAT RIDGE PLANNING DIVISION STAFF REPORT Community Development Director DATE: December 16, 2014 Lauren Mikulak WA -14 -19 / TCN Approval of a 2 -foot (10 %) variance to allow accessible parking spaces and aisles that are 18 feet in length within a private parking lot LOCATION OF REQUEST: 7340 W. 44th Avenue APPLICANT (S): Town Center North Apartments, LLC OWNER (S): Wheat Ridge Urban Renewal Authority APPROXIMATE AREA: 60,815 square feet (1.396 acres) PRESENT ZONING: Mixed Use - Commercial (MU -C) PRESENT LAND USE: Vacant site ENTER INTO RECORD: (X) CASE FILE & PACKET MATERIALS (X) ZONING ORDINANCE Location Map Site JURISDICTION: All notification and posting requirements have been met; therefore, there is jurisdiction to make an administrative decision. I. REQUEST The applicant is requesting approval of a 2 -foot (10 %) variance to allow accessible parking spaces and aisles that are 18 feet in length. The applicant, Town Center North Apartments LLC, is requesting the variance as the prospective purchaser of 7340 W. 44th Avenue. The purpose of this request is to accommodate a slight shift in the main building as required by HUD regulations and to avoid a meandering sidewalk design. Section 26 -115.0 (Variances and Waivers) of the Wheat Ridge City Code empowers the Director of Community Development to decide upon applications for administrative variances from the strict application of the zoning district development standards that are not in excess of fifty (50) percent of the standard. II. CASE ANALYSIS Existing Conditions The site is located on the south side of W. 44` Avenue between Upham and Vance Streets (Exhibit 1, Aerial). The property is zoned Mixed Use - Commercial (MU -C) and is surrounded by a variety of land uses. Properties to the west and south are also zoned MU -C and include the Panda King restaurant and an 88 -unit, income- and age - restricted apartment building. Across Wadsworth to the north are parcels zoned Commercial -One and Restricted Commercial with a variety of small retail and service businesses. Immediately to the east is a lower density residential neighborhood zoned Residential -Two (Exhibit 2, Zoning Map). Proposed Redevelopment A site plan for the subject property was recently approved on November 11, 2014 per Case No. WSP- 14 -03, and a building permit was approved by the Zoning Division on December 1, 2014. The proposed site plan represents a second phase of redevelopment in the area. The applicant previously built the 88 -unit building to the south, and is proposing a four - story, 50 -unit senior apartment building on the subject site. The approved site plan complies with all development standards in the mixed use zoning in terms of site design, architecture, parking and landscaping. Subsequent to the site plan approval in November, the applicant learned that the building would need to be shifted because of requirements from the U.S. Department of Housing and Urban Development (HUD). The developer, Wazee Partners, has been awarded federal low- income housing tax credits to construct the project. As a HUD - assisted project it is subject to separation requirements from certain land uses which HUD considers potentially harmful. In this case, there is a propane sales business to the northwest at 7405 W. 44` Avenue. Based on the size of the propane tanks at that business and based on the height of the proposed apartments, the building needs to shift approximately two (2) feet south and five (5) feet east. This shift impacts the parking area which wraps the building to the south and east (Exhibit 3, Site Plan). 2 Requested Variance Section 26 -501 of the Wheat Ridge municipal code establishes standards for off - street parking areas. For perpendicular parking spaces, the zoning code establishes the following minimum dimensions: The minimum width of accessible parking spaces can vary from 8 to 11 feet based on the width of the adjacent access aisle. The zoning code does not regulate the length of accessible spaces, but states "said spaces shall have a minimum access aisle length of twenty (20) feet" (Sec. 26- 501.E.9). This is an unusual standard because neither the International Building Codes nor the ANSI accessibility codes prescribe minimum dimensions for parking stall length. The Americans with Disabilities Act (ADA) Standards state that "access aisles shall extend the full length of the parking spaces they serve" (Sec. 502.3.2). Based on zoning code requirements, the proposed site plan includes four (4) accessible parking spaces (Exhibit 3, Site Plan). The originally approved parking plan was able to accommodate the 20 -foot aisle length by jogging the adjacent sidewalk. Because HUD standards require the building to shift 2 feet to the south, the applicant is proposing an amended site plan that eliminates the 2 -foot sidewalk jog and makes all parking spaces and aisles a uniform 18 feet in length. This will also allow three compact parking spaces to become standard parking spaces. Posting Period During the public notification period no objections or written comments were received. One neighbor contacted staff to learn more about the variance request. III. VARIANCE CRITERIA In order to approve an administrative variance, the Community Development Director must determine that the majority of the "criteria for review" listed in Section 26- 115.C.4 of the City Code have been met. Staff provides the following review and analysis of the variance criteria. 1. The property in question would not yield a reasonable return in use, service or income if permitted to be used only under the conditions allowed by regulation for the district in which it is located. If the request were denied, the property may continue to yield a reasonable return in use, although the site and building design would need to be entirely reconfigured if the request is denied. Staff finds this criterion has not been met. 3 2. The variance would not alter the essential character of the locality. The variance will be imperceptible to most users and neighbors, and is therefore not likely to alter the character of the locality. The parking area is internal to the site, and the linear sidewalk design being proposed in association with the variance is less impactful than the meandering sidewalk that was part of the original design (Exhibit 3, Site Plan). Staff finds this criterion has been met. 3. The applicant is proposing a substantial investment in the property *vith this application, which would not be possible without the variance. The applicant is proposing a substantial investment in the property, which may not be possible without the variance. The project has been awarded $965,327 in low income housing tax credits, and the redevelopment will result in an investment of several million dollars. The investment is not possible unless the building is shifted to accommodate HUD standards, and the variance is needed to accommodate this shift. Staff finds this criterion has been met. 4. The particular physical surrounding, shape or topographical condition of the specific property involved results in a particular and unique hardship (upon the owner) as distinguished from a mere inconvenience if the strict letter of the regulations were carried out. The unique condition that affects the property relates to the proximity of the propane provider and the HUD - assisted financing that requires a minimum separation from this land use. The regulation is not included in International Fire Codes, and the applicant was unaware of the issue until well after site planning had been completed. The applicant has pursued alternative solutions including relief from HUD standards, alternative site designs, and off -site improvements at the propane business. None of these alternatives have been viable, and the variance request has been a last resort in response to the unique hardship. Staff finds this criterion has been met. 5. The alleged difficulty or hardship has not been created by any person presently having an interest in the property. The unique hardship relates to the proximity of adjacent land uses and HUD regulations. The hardship was not created by the current property owner or any person currently having an interest in the property. Staff finds this criterion has been met. 6. The granting of the variance would not be detrimental to the public welfare or injurious to other property or improvements in the neighborhood in which the property is located, by, among other things, substantially or permanently impairing the appropriate use or development of adjacent property, impairing the adequate supply of light and air to 4 adjacent property, substantially increasing the congestion in public streets or increasing the danger of fire or endangering the public safety, or substantially diminishing or impairing property values within the neighborhood. The request will not be detrimental to public welfare and is not expected to injure neighboring property or improvements. It will not hinder or impair the development of the adjacent properties. The adequate supply of air and light will not be compromised as a result of this request. The request will not increase the congestion in the streets, nor will it cause an obstruction to motorists on the adjacent streets. The structure will not impede the sight distance triangle and will not increase the danger of fire. The request will not impair property values in the neighborhood; a successful redevelopment may in fact have a positive effect on property values. Staff finds this criterion has been met. 7. The unusual circumstances or conditions necessitating the variance request are present in the neighborhood and are not unique to the property. The unique conditions are specific to the subject property by virtue of being a HUD - assisted project. Staff finds that this criterion has not been met. 8. Granting of the variance would result in a reasonable accommodation of a person with disabilities. While the variance will result in a reduced length for access aisles, the length is in keeping with federal accessibility standards which only require that the aisle be the same length as the accessible parking space. For this reasons, the variance will result in a reasonable accommodate of persons with disabilities. The adjacent sidewalk will be linear as a result of the variance and may also be easier to navigate for persons using the subject parking spaces. Staff finds this criterion has been met. 9. The application is in substantial compliance with the applicable standards set forth in the Architectural and Site Design Manual The Architectural and Site Design Manual (ASDM) does not apply to properties that are zoned Mixed Use - Commercial (MU -C). Staff finds this criterion does not apply. IV. STAFF CONCLUSIONS AND RECOMMENDATIONS Having found the application in compliance with the majority of the review criteria, staff recommends APPROVAL of a 2 -foot (10 %) variance to allow accessible parking spaces and aisles that are 18 feet in length. Staff has found that there are circumstances attributed to this request that would warrant approval of a variance. Therefore, staff recommends approval for the following reasons: I . The variance would not alter the essential character of the locality. 2. The applicant is proposing a substantial investment in the redevelopment of the property that may not otherwise be possible without the variance. 3. The request will not be detrimental to public safety or welfare. 4. The proximity of a propane provider and the application of certain HUD regulations result in a unique hardship that constrains the site design. 5. The alleged hardships have not been created by any person presently having an interest in the property. 6. The variance will result in reasonable accommodations for persons with disabilities. With the following conditions: 1. The revised site plan sheet shall be appended to the plan set associated with the approved building permit 2. Prior to issuance of the Certificate of Occupancy, the subdivision plat shall be amended to reflect the updated location of the detention easement. T EXHIBIT 1: AERIAL The subject property is outlined in bright blue. The yellow star identifies the location of the propane provider that triggers the HUD separation requirement discussed in this report. EXHIBIT 2: ZONING MAP The subject property is outlined in bright blue and is zoned Mixed Use - Commercial (MU -C). SITE PLANS EXHIBIT 3 The following pages include two excerpts from two site plans: 1. The original site plan approved in November 2014 per Case No. WSP-14-03, 2. The proposed site plan associated with this variance request. The subject parking spaces are highlighted in yellow and the adjacent sidewalk in blue. The parking spaces that were compact in the original plan and now standard in the proposed site plan are shown in orange. 2 PP 5 PA 68D 5 CS 1 MR SIGHT DISTANCE TRIANGLE PERENNIAL MIX �12CAO IJ� WW • J� I EWWA 0 W Ie _ MAI >' 1+ �..00 Lt 1 0%..00 ' r o•so O� SIGHT ' f ` TRIANGLE 2 PIP 4 PO [O � ..■ ■ . w Cu 38D :. :. • I QII 4 is acs ' I 5CS ;. • METAL EDGi NG . M BO LLARDS JINNI 6 CAO 12 CC 2 PP 5 PA 68D 5 CS 1 MR SIGHT DISTANCE TRIANGLE PERENNIAL MIX �12CAO MSE RETAINING WALL. SFF CIVIL DWGS ^ -4--j W ii PF 5' HT. E 1'., FENCF /fit DOG F \ G J ASTI -PP ACE DOUb r1 _J 10 PF 45 STS 1 G ORIGINAL SITE PLAN 0 ' f ` ►� FO � ..■ ■ . WA • I fA Q �� O, :. , I QII I t`001.� .y< 0 • . 6 CAO 12 CC �O 00 O SIGHT DISTANCE Ilill�lllll "'7A'i MSE RETAINING WALL. SFF CIVIL DWGS ^ -4--j W ii PF 5' HT. E 1'., FENCF /fit DOG F \ G J ASTI -PP ACE DOUb r1 _J 10 PF 45 STS 1 G ORIGINAL SITE PLAN 2 -- -- 44th Avenue - 2 PP 2 PP 5PA PERENNIAL MIX . M r 5PA Sao 14 ICR —FENCE (TYP) 4 BD g C$ ' 2 MR - 8 CAD 4 BD - _ _ - - 5 - q C$ 3OR - I SIGHT DISTANCE TRIANGLE PERENNIAL MIX -- 1�9 setback 12 CAO - SIGHT OI .. TRIANGLE 2 PP 4 PO MSE RETAINING 11 setback 11 PA 5PA 4 JS 1 WALL. SFF CIVIL DWGS 3 BD 460 1 GD — _. 4 4 JS 8 CS 5 CS 4CC 2 PP 3 PO 8 JS (� „ PF }� (2) 9 BOLLARDS J ♦ ^ 4 PC v / v J 6 CC COLORED CONCRETE PAVERS 6 CAD PERENNIAL 5' HT. ,C 12F. U - MIX y_ L _ - - - FENCE /T! <V 3 S a DOG F ` ASTr C Arc 5 CAD 25 RWWK DOUb r1 MS WI ` v, 6 HES 50 STB I i ® DWGS. 50 STS -° - - PERENNIAL MIX .w.. OUTDOOR GRILL (10)4'x8' RAISED PLANTER \ _ *x4'6' I- — - 2 _ 1C FIRE PR i GT (3) BENCH, TYP. I 1 GT (1x16" AM FLE AREA) 3 CAO �- 12.CC 1 GT 10 Pf SIGHT DISTANCE 3 ' SIGN n n n 45 STB TRIANGLE 6 WS - gO-0-- 4 CC 6H S °� — - -- — - '.....' J 1 GD ❑ ❑ C ❑ PERENNIAL MIX I . (15) 4'x4' RAISE PLANTERS .-_ CRUSHER FINES (TYP) REVISED SITE PLAN Lauren Mikulak .74W pe - eUdle FIT ;�ulc IF . 1 0 work with Kephart to get the building rmit plan set updated and either Fred or Rick will send over the civil construction plans to Dave, Thanks again! From: Lauren Mikulak [mailto:lMjkul rl s Sent: Tuesday, December 16, 2014 11:55 AM To: Tyler Downs Cc: Fred Tafoya (fta_f_oXa_A_rqd1and&_qm); Rick Rome; Steve Art Subject: Site Plan Approval Tyler, Attached is a letter indicating approval of the amended site plan and associated variance (I just gave hard copies to Chris). Please note that based on the amended site plan the following items will need to be submitted: CONFIDENTIALITY NOTIM This e-mail contains business-confidential information. It is intended only for the use of the individual • entity named above, if you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is �jrohibited. IfWov_L4e4rg_*t this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you, I Lauren Mikulak From: Dave Brossman Sent: Wednesday, December 10, 2014 3:41 PM To- Lauren Mikulak Cc: Steve Nguyen Subject: RE: Referral :: TCN - Revised Site Plan Attachments* imageOO1.jpg; Civil Construction Plans-Re-Design Review-l-APPROVED-E-mail,pdf They will of course have to address the matter of the revised detention/drainage easement. Due to the complexity of that easement I would greatly prefer that they submit an amended plat with a purpose stated on it (purpose = to revise the geometry of the underground detention drainage easement). While in most cases we can accept an Affidavit of Correction to modify easements, this was not an error but a modification due to site changes, so in my opinion the Aff of Corr is not the correct method of fixing this. Face it, their surveyor would have been paid for an exhibit to go with the Affidavit anyway so cost shouldn't be a big factor - and it will be a quick Admin review so that shouldn't be a big deal either. But the easement is to the benefit of the City and I believe they should provide us with an amended plat reflecting the ultimate (and correct location). Due to the file size I will be sendine the a roved docs in 2 1V 11 =U LAV N71QM lil #1 In addition, they will need to provide us with the following: 1. They will need to e-mail me or include on a disk an AutoCAD DWG file in 2010 (or older DWG format) AND 2. They must send the usual four (4) signed and sealed hardcopies of the civil construction plans for the Building Permit Application (I will swap them out the previous ones). D. From: Lauren Mikulak Sent: Thursday, December 04, 2014 5:37 PM To: Dave Brossman Subject: Referral :: TCN - Revised Site Plan The building for Town Center North is, in fact, shifting several feet because of the propane tanks. Among other things, the shift appears to impact the drainage improvements, so I've uploaded the revised site plan and civil docs for your 0 Lauren Mikulak From: Dave Brossman Sent: Wednesday, December 10, 2014 3:41 PM To: Lauren Mikulak Cc: Steve Nguyen Subject: RE: Referral:: TCN - Revised Site Plan Attachments: imageOOljpg; Civil Construction Plans-Re-Design Review-l-APPROVED-E-maii.pdf I have cortiI mii review all of the documenUs&id1#A,*x* the detention facility and the associated drainage easement none of these changes appear substantial enough to agrait moi"fi They will of course have to address the matter of the revised detention/drainage easement, Due to the complexity of that easement I woul I reatl refer that the su While in most cases we can accept an Affidavit of Correction to modify easements, this was not an error bu modification due to site changes, so in my opinion the Aff of Corr is not the correct method of fixing this. F c it, th surve4or would have Wbeen Waid for an exhibit to go with th Affif ire 111 0111 W M1111 191911"r • # #- Itt _- MAIMAIN HIMMMI I 1 1 1 1 10041 In addition, they will need to provide us with the following: 1. They will need to e-mail me or include on a disk an AutoCAD DWG file in 2010 (or older DWG format) AND 2. They must send the usual four (4) signed and sealed hardcopies of the civil construction plans for the Building Permit Application (I will swap them out the previous ones). Thanks and have a great afternoon/evening! D. From: Lauren Mikulak Sent: Thursday, December 04, 2014 5:37 PIV To: Dave Brossman Subject: Referral :: TCN - Revised Site Plan review. Evidently, they cannot close on the property until the revised site plan is approved, and the URA contract requires a closing before the end of the year. To help Tyler and Steve meet the closing deadline, we're targeting the week of December 15 to approve the site plan, That gives us all 2 to 3 weeks. A nkntcan be modified later but will have to be recorded (either a separate document or replat) before the building CO is issued. At this point the critical path is approval of the site plan and civils. I know we're is already swamped, but hopefully it's a minor review since it's a minor shift, I'll give you the hard copies that they provided. Digital versions are in the V drive. Let me know if you have any questions. Folder: V:\Community Development\_Land Use Case ge.�rraI<fjjC;j�jV;\Commun[tV ,YQ2QP"el Pment\ 12 1 RE 5 R. i MMUMTRUBM GM 41=21r," 11MORIMMOMMIMMME I didn't make a referral form (you're the only one reviewing this), but I will track the modification with a case number: WSP-14-0& I RM-M-M SIM NOW CONFIDENTIALITY NOTICE: This e-mail contains business-confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage • use • this communication is prohibited. if you received this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected, Thank you. N City of W heat R,,:jge POSTING CERTIFICATION CASE NO. WA -14 -19 DEADLINE FOR WRITTEN COMMENTS: December 15, 2014 F (name) residing at a300 �itc �'lG,b�t 3.Z5 ✓�ek�r� o ,20,� (a dress) as the applicant for Case No. WA -14 -19 Public Notice at on this 5`" hereby certify that I have posted the sign for 7340 W. 44 °i Ave (location) day of December and do hereby certify that said sign has been posted and remained in place for ten (10) days prior to and includin �e deadline for written comments regarding this case. The sign was posted in t o ' ion s own on the m elow. Signature: 12, NOTE: This form must be submitted to the Community Development Department for this case and will be placed in the applicant's case file. MAP 4000 0#� of Wi��- ge • I---,--- , " 111111111- 1 • (as required pursuant to Code Section 26-109.D) This is an administrative variance review with a 10-day posting period. Public comments concerning this request are due in writing • 5:00 p.m. on December 15, 2014, I Kim Administrative Assistant, Comm QeRa dt�ment hereby certify that I mailed a total of 8 letters on December 5, 2014 to the attached recipient list, City of WheatR ' e COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29" Ave. Wheat Ridge, CO 80033 -8001 P: 303.235.2846 F: 303.235.2857 LETTER NOTICE December 5, 2014 Dear Property Owner: This is to inform you of Case No. WA- 14 -19, a request for a 2 -foot (10 %) variance to allow accessible parking spaces that are 18 feet in length within the private parking lot for property located at 7340 W. 40' Avenue. The attached aerial photo identifies the location of the variance request. The applicant for this case is requesting an administrative variance review which allows no more than a fifty percent (50 %) variance to be granted by the Zoning Administrator without need for a public hearing. Prior to the rendering of a decision, all adjacent property owners are required to be notified of the request by certified mail. If you have any questions, please contact the Planning Division at 303 - 235 -2846 or if you would like to submit comments concerning this request, please do so in writing by 5:00 p.m. on December 15, 2014. Thank you. WAI419.doc ww w.d.w h eat ridge.co. u s Site Plan A request for a 2 -foot (10 %) variance to allow accessible parking spaces that are 18 feet in length within the private parking lot for property located at 7340 W. 44`" Avenue. UU ddth Awom io P� 6 PA SONT d6T##4f 11 14ULL PLRLNNW. MIX � CD w L� U C n I bgrt pl5fa.CE RJSHER FINES CYPy MSC RE TAIMA* WALL. SEE OVIL I'MOGS -I--# / 11 FF U) / 5 MT E I/ARA, . FkhcF Ca ASTr URFAU — DJUo LANDSCAPE PLAN ^ . . 1� A AAA PROPANE SALES BOROUMAND ENAYATALLAH CARVER AMY MARIE 7405 W 44TH AVE 1980 AGB TRUST CARVER RICHARD A WHEA'FRIDGE CO 80033 PO BOX 117639 4360 UPHAM ST BURLINGAME CA 94011 W14EAT RIDGE CO 80033 ROACH INVESTMENT LIMITED PARTNERSHIP RLLLP 6545 W 44TIl AVE WHEAT RIDGE CO 80033 SWEET RIDGE LLC 4471 UPHAM sT WHEAT RIDGE CO 80033 WHEAT RIDGE TOWN CENTER APARTMENTS LLLP 2300 15TH ST 325 DENVER CO 80202 WHEAT RIDGE URBAN RENEWAL AUTHORITY 7500 W 29TH AVE WHEAT RIDGE CO 80033 Owner t Owner 2 Owmr 3 Cmpany Mailing Addm" St Street Name Type JU.It City State Zip Pmperty Address St Street Name Type City State Zip Use AAA PROPANE SALES 7405 W 44TH AVE WHEAT RIDGE CO 80033 7405 W 44TH AVE WHEAT RIDGI CO 80033 COMMR BOROUMAND ENAYATALLAH 1980 AGB TRUST PO BOX 117639 BURLINGAME CA 94011 75-40 W 44TH AVE WHEAT RIDGI CO 80033 COMMR CARVER AMY MARIE _ CARVER RICHARD A 4360 UPHAM 5T WHEAT RIDGE CO 80033 4360 UPHAM ST WHEAT RIDGI CO 8DO RESID FLJEDER JOHN R 7250 W 44TH AVE WHEAT RIDGE CO 80033 7250 W 44TH AVE WHEAT RIDGI CO 8W33 COMMR FLIEDER JOHN R 7250 W 44TH AVE WHEAT RIDGE CO BM33 725 W 44TH AVE WHEAT RIDGI CO 80033 COMMR ROACH NAIESThENT L MMW PAIF RLLLP 6545 W 44TH AVE WHEAT RIDGE CO 80033 7393 W 44TH AVE WHEAT RIDGI CO 80033 COMMR ROACH INVftTA�EN UWTIED RLLLP 6545 W 44TH AVE WHEAT RIDGE CO 80033 7393 W 44TH AVE WHEAT RIDGI CO 80033 COMMR ROACH INVESTMENT umrrEi5 PAF RLLLP 6545 W 44TH AVE WHEAT RIDGE CO 80033 7337 W 44TH AVE WHEAT RIDGI CO 80033 COMMR SWEET RIDGE LLC 4471 UPHAM ST WHEAT RIDGE CO 80033 7301 W 44TH AVE WHEAT RIDG CO 8003 RESID WHEAT RIDGE TOWN CENTER AP 2 15TH ST 325 DENVER CO 80202 4340 VANCE ST WHEAT RIDG CO 8003 COMMR WHEAT RIDGE URBAN RENEWAL 75 W 29TH AVE WHEAT RIDGE CO 800 734W 44TH AVE WHEAT RIDG CO 80033 CD CD U) W ll� NG VL 5,o IT D15 AgCE I )p W. 44th Avenue ,� 5 PA 5 P" .1 Rr 7 8I514' #' RAIRFOPI WrPrV9 CRUSHER FINES ilYP) 10 P 45 t; I It LANDSCAPE PLAN -AOHT DISTANCE IMAWXL PERENNIAL MIX 12CAO MSERETA1414G WALL. SEE GVIL Mor-S -0--p a) c/) R HTE IIA"t FMQ cu I =k E URFACE --- -Dcxjb M 8I514' #' RAIRFOPI WrPrV9 CRUSHER FINES ilYP) 10 P 45 t; I It LANDSCAPE PLAN Sr I t ' AV � A �`� -- -- VANCE ST r A . Oil 11 IX�J!! OW + �l L LPHAWST jV ,. r r TELLER•S. ,,. Case No. WA1419 Date Received 1 2'412014 Related Gases WSP1408 & WSP1 Case Planner M kulak Case Descriptior'A request for a 2•foot 10i variance to "allow' accessible arking spaces that are 18 feet in length within - t he , f �) p private parking tot �J}Gr.3u7f ,�PdY'r�J;dSr�l/YY?!7 Name Town Center NorthApartrr Name Phone (720) 420.1568 Address 230015th Street Suite 325 City Denver State :CO Zip, 80202. L7�rrrr /rrJvsrxcr�r�rr�r _ __ .. Narrre Town Center North Apartrr Name Phone (720)42A�1568 Address 2300 15th Street Suite 325 City 'Denver State ;CO Zip 80202' C�ar.*f«��f l,rh�r�►xruriixr Name: Tyler Downs . Waxee Part Name Town Center Not thApartrc Phone ,(720) 420.1568 Address 230015th Street suite 325 City Denver State CO Z ip ,80202 r�*ir~,�e^t lrrfr�rlrl'nrrr Address 7340 Street W 44th Ave.. City WheatRidge State CO zip sbdn Location Description Protect Name Parcel No Qtr section District No Parcel No, 39. 234.12. 001 Qtr Section: SE23 District No.: tl I 3923412001 SE23 I! �ei�t*Ylt tx":C Pre-App Date Neighborhood Meeting Date App No: Review Type Review Body Review Date Disposition Cents Report Review Admrn F Case Disposition Disposition Date Conditions of Approval Notes _ Status Open Rees It Ord g Storage: i, A City of ]�9 LAND USE CASE PROCESSING APPLICATION Community Development Department 7500 West 29' Avenue * Wheat Ridge. CO $0033 * Phone ( 23 5 5- 18,14 (Please print or type all information) Applicant Town Center North Apartments LLLP Address 2300 15th Street Suite 325 Phone 720A20.1568 CitY-2e_nver State Colorado Zij) 80262 Fax 877.444 Owner Town enter North A artmentst-LLP Address 2300 15th Street Suite 325 City_____P�enver State Colorado Zip__�0202 Tyler Downs: Wazee Partners, LLC Contact zge Town C-165-MrA—panrents Address 2300 15th Street Suite 325 Phone 720.420.1568 City Denver — State Colorado Zip 80202 Fax 877.444.1877 (The person listed as contact will be contacted to answer questions regarding this application, provide additional information when necessary, post public hearing signs, will receive a copy of the staff report prior to Public Hearing, and shall be responsible for forwarding all verbal and written communication to applicant and owner.) Location of request (address): 7340 W. 44th Avenue, Wheat Ridge, CO 80033 Required information: Assessors Parcel Nurnber: 39-234-12-001 Size of Lot (acres or souare footaiwl: 60,815 sf My commission expires 0 _L _f It /20 To be filled ou� b staff: 0 Date! received 12-1 Comp Plan Desigan Related Case No, W Fee ' eccipt No. Zonin—g - ---- " - Pre-App Mtg, Case No,, VVLk Quarter Section M Section Case Manager ;� Case No. WSP1408 Date Received 1214P d Relat d Cases �VA1419 & WS014f! Case Planner Mikulak Case Descriptior Review and approval of Site Plan Amendment No. 1 to the Wheat Ridge Town Center North Apartments. Name Town Center North Apartrr; Name Phone j72t1j 4201558 Address 230015th St,. Ste 325 City Penver State to Zip 86202- 11wrtie,r 1,?1ovs tbi;vr Name Town Center No .. rth Apartrr Name _ Phone (72b 420•1 588 Address 230015th St Ste 325 City Denver __ Skate CCt dip 80202 - Name Tyler Gowns: Wazee Parkr Name Wheat Ridge Town Cente r Phone C720� 40.15fiS Address 230015th St , Ste 325 City $Denver State CC1 Zip '80202 >r�"f l,,u�rataarr Address ,7340 Street W 44th Ave . _ .. City :Wheat Ridge State CO ' Zip .80033 Location Description Project Name �� N cat No Ott District No - Parcel Na 39.234.12 ^001 . . . , Qtr Section: SE23 District No,: II' � 3923412001 SE23 11 . _..�. Pre-App Date Neighborhood Meeting Date App No• Rt'vBt?44e Type Review Body Review Date Disposition Co t$ Report Rev +ew Adrrrrn... „ d II %:;art xtf /t'rx+;" Cane Disposition Disposition Date Conditions. of Approval .. , .. w , Notes Status Dpn _ Ras 4 Ord Storage WHEAT RIDGE TOWN CENTER NORTH APARTMENTS SITE PLAN AMENDMENT NO. 1 LOT I OF TOWN CENTER NORTH SUBDIVISION. FILING NO 2 LOCATED IN THE THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER SECTION 23. TOWNSHIP 3 SOUTH RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN. CITY OF WHEAT RIDGE. COUNTY OF JEFFERSON STATE OF COLORADO STATEME OF PROPOSED U SE AND COMPLIANCE WITH BONING _ c LEGAL DESCRI «m m .camu+..wee. CONCEPT PLAN COMPLIANCE SHEETINDEX E 6 SITE 3 COVERSHEET ] 0 SITE PLAN 30 GR ADINGANDUTLITYPLAH .0 SHEETINDEX SHEET NO DESCRIPTION 10 COVERSHEET ] 0 SITE PLAN 30 GR ADINGANDUTLITYPLAH .0 LANDSCAPE PLAN SO PLANT LEGEND& NOTES EXTERIOR LIGHTING SITE AND BUILDING SIGNAGE VICINITY MAP OWNER'S CERTIFICATE CITY CERTIFICATION _ THE Cn +a r»E.r •m&r ARCHITECT cans *w ww..H.E,ec,o.r. KEPHART •EO,wER we wLn.Ar rncu u ec.uE olNn&noeR •uw wow Era•wlnrLOeR «LHHn a c c�$ g j�5 Z ( $j i `g1ll v . ENGINEER LANDSCAPE ARCHITECT V LA r) elELrinf 1 OF 5 V) H Z CASE HISTORY W Q w WSP -14 -03 0 2 = WCP -14 -02 Q co MS -14 -05 Q ZO Of WSP -13-01 w WCP -13 -01 O WSP -11 -01 Z w U WCP -11 -01 U MS -11 -02 $� WZ -10 -07 H WZ -77 -22 ENGINEER LANDSCAPE ARCHITECT V LA r) elELrinf 1 OF 5 WHEAT RIDGE TOWN CENTER NORTH APARTMENTS SITE PLAN AMENDMENT NO. 1 LOT 1 OF TOWN CENTER NORTH SUBDIVISION FILING NO 2 LOCATED IN THE THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER, SECTION 23 TOWNSHIP 3 SOUTH RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN CITY OF WHEAT RIDGE. COUNTY OF JEFFERSON. STATE OF COLORADO NTH AVENUE ROW. VAPAW W� 11Mllele � -. IWYM WAIa fvNJ —s naArlau \ gUlallra / W1l ri9fAA1� - - AsWpwaawr mw sea.raaw - w w �' LOT 1 I 4 T m u LOT4o d SUBDIVISION CENTER era �.e TIME SQUARE = ' NORTH SUBDSION - rw � \ SUBDIVISION < $ cm it n „ > g rEASEiErn WAU UUrf T'vl\ ' utE _ rrwh KUwH.aw 1 1 6 s, 000rar wnwe rtw.l rw.ra bE Huaiau.ar - `uoenaaaw — 1 % nnl A /� moT aar lrAO � 'oe�wnc« rw I ? >. - ¢I - L — m0,05 N09' aT 71 - g ram LOT 3 uas�r TOWN CENTER m 'y, LOT 2 NORTH SUBDIVISION a n,rw TOWN CENTER NORTH SUBDIVISION ARCHITECT ENGINEER n nw.,�.o`"`T' � 1 � ■ � �'"c`on`on "sACn.wr.eme N� coaucT w oaa v.a.ue.ac�e K E P H A YT cw* er w —I T-1 EXISTING LEGEND canna srneeT rwrn PROPOSEDLEGEND m a� - doe[O V,TH �N�.«raTEO,a.T SCALE t' � N LANDSCAPE ARCHITE c s Z In f LU W I- 2c W Q Z Q � = J �o a �z W F Q �j F (n Z W U O 2 OF 5 1 WHEAT RIDGE TOWN CENTER NORTH APARTMENTS SITE PLAN AMENDMENT NO. I LOT I OF TOWN CENTER NORTH SUBDIVISION, FILING NO 2 LOCATED IN THE THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER SECTION 23 TOWNSHIP 3 SOUTH RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF WHEAT RIDGE COUNTY OF JEFFERSON. STATE OF COLORADO W. 44TH=UE Atp t-\ y L Z EXISTING LEGEND FFE=5412 20 aqr LOT i TOWN CENTER MT�H IYISICN 0 LOT 4 TIM E SQUARE SU BDIVISION > — — — — — — — L PROPOSED LEGEND Z xer - 7 10N wml!p Yun ma: 7, 4 k : U) =cZT7 z LU LOT 2 TO M CENTER NORTH SUBDIVISION W 0 z o d w w U 0 ARCHITECT ENGINEER LANDSCAPE ARCHITECT K 3 0 F 5 EPHART WHEAT RIDGE TOWN CENTER NORTH APARTMENTS SITE PLAN AMENDMENT NO.I LOT T OF TOWN CENTER NORTH SUBDIVISION. FILING NO 2 LOCATED IN THE THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER SECTION 23. TOWNSHIP 3 SOUTH. RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF WHEAT RIDGE. COUNTY OF JEFFERSON. STA TE OF COLORADO LEGEND 0 RNADE TREE ¢Y��}0 [7�7} ORNAMENTAL TREE EVERGREEN TREE 8 b CI SHRUBS 6 ORNAMENTAL GRA55E5 O O PERENNIAL MI% TURF CRUSHER FINES O BENCH 5TEE1EDGINC ii N. =PP S PA am SIGHT WSTANCE TRWIGLE PERENNIAL MI% 13 CAO — RETAINING WAIL. SEE GML OViR'S I ' �--5 HT ALUMINUM RAIL FENCE 1 _ DOf RUN VATn ASTROTURF SURFACE GOUBLE WTE as LANDSCAPE PLAN 1�1 9 8 / Z.,ii f^ e LLJ z z Ill a wa �a LU ox � o z LU z Lu 0 O F . z a J a W a a U In 0 z a J ARCHITECT ENGINEER LANDSCAPE ARCHITECT RFE, A ■ In�nETO c`o �IISTRLT:. s,RE �I f,_r) co co�.n oow v.H�wewc.E S ! P H A P T mR ",a _ - =— c�ox*c* �� Rce ww �T° RRIti1NA 4 of 5 WHEAT RIDGE TOWN CENTER NORTH APARTMENTS SITE PLAN ANIENDNIENT NO.I LOT T OF TOWN CENTER NORTH SUBDIVISION. FILING NO. 2. LOCATED IN THE THE NORTHWEST OUARTER OF THE SOUTHEAST QUARTER, SECTION 23 TOWNSHIP 3 SOUTH RANGE 69 WEST OF THE 6TH PRIAC /PAL MERIDIAN CITYOF WHEAT RIDGE, COUNTY OF JEFFERSON STATE OF COLORADO PLANTING NOTES PLANT LEGEND o> — Trees 9rm Bobnlc Nur Cwnrun Neme GD Gymrocbdn ewwua'ospasso E-- ..rdu<4Y CoX «b» DT Gbe45r lmnnrwa rornn'Inpar Irtgeral Ho «ybcurl OR Oarcva rude Norllrem Red Ony T»a IS AmOxrua ecopdorum'M.ewi M.ewa Anpsr Dolly � 0E s prpu 0- E,- Be OmMbMal Tre» MR W-0S.KW Y Royal R—­, Royal P—M CMbppb PC Pyres nleryam'CMrlwYSf CMnbcroer Peer D.c1lsrn /_E � n SNUb BD Breebr bvga'Aeows BNB' CortpeU Bnr BM1.AW Burn CC Ceryopbm,WMOn.a'aM1 Kmple' WM1 KMyd Bps Mra 5 «ea CB Cana ambMen'Fene' ArUC Fee poPvreoe PA Prue ebra'T — DvgA N—1,y Sgel1 PF — 4 Kan» Os»A EMO«an CMlfy 1 La «Co�tacaor.haubrsspomide br MCOmrq bmlwr mm all rnwerpraunA urnNer pores aM MrvcMea TM ConlraMer rMl b MM � n, �n„ n., w< eMatlr�axa� ,ro,�nw,lertnbb<a�na.11ew�rmepw Ad Im., pwr ro.n o.nvemn TM urornp corro,<1or a,ax uae,nb pomOYy M aM con .wwr.e e« ro earraPO of »b uNrtws Can Bt l Boron v« Dq 2 W not nxNrlly poceoa +.N cwarucmn as a »qua wsn X a Demos m.l er pan ellererw.s e, W tMt rraY M Mva ban rn eureq «rgn Srcn aMmwr aMY b enrM4Mry brorrpld b IM son al Wr W «MI GOMraaw arM QMr(a Rep.e.rX.be TM Unesc.q Cenbcror rbn..vbr ler n,prmXaYty Ip ar news »ry remmnr eu. b IeMAe b 9^'e wcn «Mwalwn Y X OMecs. err» ben sae el aMSS eM pans. f A — 1 l. DoroMOI ro nMaa wls RepanM,M1ro or Fa resoWwn rlre a rtbae wch ceHach b N. Omroyf Repe »Malrve wall resW m COm.UOya bbMy le robceY melerb4 1 TM lArMec1« Connor Lr1 mMy Or 1. R..--- n —1 pmr b nmrrnwmeM a nol4 ro oowearab po1M mspsUbn xheeu4e 5 TM lepwee KrNbnq ae0 ro Ld 1 Me .Yearly ban appwaa eM peWP41.e b.aaoaelbn orbs G» Ne. MSI l-0Z 6 LaMSUb Cenleper.Mr peHi pw VM cosh M every s¢e a p4M 1, arM tY Iy« b nr.e orX « Pbrdaq Pbns UrM na Ie rncbMS tlr pbM rrvroMl tlrebbe mcaMap s1 bbr, «wpnM ewnrrorda. 4MNan. .M aMr rrrlanb ea aYtl.e rp.cMe for estlr s¢e r n Xr LAMan» CoMMCbYe rsspensidMy b Mnen pbM mebsah h» a N. U r i»sca« Cwn.cfw.rl0 b <erMIW�Wa1�ra Me.» w N N� b L.Mxap GOMrecloh OWgbon b eernMy a0 pan ma1Mb1 M hw ye.n rows Rral eccaparms 8 L.MU.» Cwmecmr MaY b n.penr-0b br.rry norJnaMn van wbcwn.aon as repm.a ro accwrrearr plaMaq op. atom a m.mMq ra.a era bona br of p4MS sea Iw MBPer sqn «alr .. uMe br «sate to An pan marorol ,wan b ..am,ebe ro «arerl <wnenon, ror n.aMa,r a e monWn taws do Mnp 11 oae�n sn aRrnrrlNMlawbry anMn oln » »..od hom.n a.a.Xba,od, ar IM mn >acbn ooM TM analys4.IW early sb »E.Biry a Xr n v r .+ l o bdr ,n.l rr..wq.a bah...rle r.Pen.nm.eebon,l , w r�wnnn b be aPenleX Ae alenel arr.r rar.a. »n mrrrM a by KweZl »rrgM e11Y b b Xre ah. LonBOn b Ea M bl.mir.X N'tlre Wmr a RepeaarbXM. TIr eor arAMrrroM. ameply ep T U It y W b Xr mvn.mpd , CO a W 3- 120 w SS— rrvar»y SW T—,,, lab A]i &NESB. Port Con. C BM211120 w erns Mp6Mf Yh IZ WM nma, are abbevabe on baweps. 5 «p4M bifw 4.Y arM tlaafd.AdN 13 sMl lora6ar a al pan rnl 1a hM Abp1 to Ne aW.-el Ns Dme Rapro»nbim la Apply A orbs Yards al orgrac nr 0 pr 1.000 rRUar. leel b 10 soU»e W. a Beene b«, Is b<or«Mro arr.rwroMr NwouXnry.Mn by B m a rod rota d.q .rrrnena ro+ m rmbn pMe. ate eb.wwnr ,noY.n on m.mrga oe rw1 nwa »da MMer rrob.t w mMey rmMlsm 18 A--sal ar»MrrMr 8 MIOrgnc, E — a Ts 3 '.150 )B WCR Eet« CO C 80815 Nvl lSa)191 17 Do rot cwmerrca arraMeq a e.nhrq »d par ro acnpanu .1 1 Xnb 18 AY pam.q dw areas one Iree panteya oval renna a man,.n a r a mrKn TM coMraUOr n Mapnsrble Iw we« corns on ber aM s «be anaa uqY ImM poleU acnparce IS Tr« peMne, era raerrrq pMa eY b ba.me xNl1 Oware bnrpbM /Tr«sl art. O.nea bee sap IPbnL.rp bhl Mcwrhv..mocv4Mr maNee.t tlro rate r.<onnnMbe W M m.raX.cMer 20 Sae ea. ds for panlvq repb.merda. maomh.aM eaecuMn 21 S—Gey an noes »preeba for• Panoeaoro year 2z. r erwMN era »«fre « prom. Ns bne.cap coneaer n 10 wbml A W a aomYy evade64 anwuh ro b uree to IM OwneYa Repre »nMtn br appov.l 23 G— corer areas era m M esrgaarry ,pane. uaasr o0rrwse snexm er nose «roe plans 21 Ar... yes »merrb awn or. .rper.y a<ns »a sNrMmam urobbrrroe arM luny aocesvW .brq New ends letph la rreebn.m eM emergncy .wnprrM aM voncba 25 CeMra <rorn rospomr.lerr«Iwaap aX Mlurbe brleuep areas arse .»em8 env mr.eeoa nrgabn nrroorrMf .rra'w Mrer<,» w•aq areas ep. ro nnrewwt.atM LANDSCAPE NOTES I ALL LANDSCAPE BEDS TO RECENE r DEPTH OF DECORATNE ROC. OR Y MULCH Z ALLTURFAREAS TOM IRRIGATEDWRNAN AUTOMATIC POP UP ANOOR ROTOR SPRINKLER SYSTEM 3 ALL PLANTING BEDS TO BE IRRIGATEDMATH AN AUTOMATIC DRIP IRRGATON SYSTEM A ALL IRRIGATION TOM CONTROLLED MATH AN AUTOMATIC IRRIGATON CONTROLLER WOTH RAIN SENSORS c 9 �m W d� 2 ' w ^ H V Z LLI J a S Cw7 2 0. S o F or Z l Z fr 5w a z w Q z U 3 N o Z Q ARCHITECT ENGINEER LANDSCAPE ARCHTECT eo�oo`s s.rF' -o� w�irA, gin pout .H wmr<+e K F P H ART � T M n � 0 ' v L FREp ar[bra BWB COMB. RRLT�NA 5of5 Dwerba r Ev _yrsen Shan Cori Sa. Sn<wq OaOY Sym Bobnc N.w COmrwn Na rtro Sse SP-Q OrMnXy 21701 bSllexn 2 PO Plryfonryur opwdoxa'Dubb' PrA,ll, --'. Sql sec. ] 21701 IS— 3 RI Re »KrwnMDeWb Sql sec 2S 2 17 nl b SMmn 3 OorW Nrrocy W Re» SJ SlrYea PPOro'AMwry VJH.r.Y AxMm Mwror.r spe.e 5 ql Y o c ] Rrern»I. Tql bSlrpxyr t8 _SL'm Nane/COmrVNanr Sae 9o.cnp _Ouarrj SM bShoxn S ASN Ow n apps t2'oc SA N- �� COG Ceroogn pnnetlbn'S,.w Sway —­ 4' W. 12'oc S1 r.. b S— l ECP EcbMn. purpwe. 1' pas 12 - o c S• TAp4 COrrBIWI HEH Ham.rocalb'Sbb M Oro' T pas 1Z• o c SA 2 17 u1 AA S— B DwaA "M DaM STB Aar. Ever D.Y -1.l Sb.wew«a Sbev.Ewrra A• pets 12 e c 115 Sql !o< Zf a ruer!I al a ..,., CAO Cabrrrpro.b.cu0lbra'KarIF «nrof 101 Yoc AB 5ql 25 Jac Grass H.W R«e HES . .­1 Bw A «na Greaa I ql 18•o c 20 Sql !oc 27 lcR l w < woe BarorY I wI 1h < 1A sql Ao< 31 Re Bsren M0 «» Bove Wass cY. »ea 501 5'0< 21 - - "' Toe SOe 1 La «Co�tacaor.haubrsspomide br MCOmrq bmlwr mm all rnwerpraunA urnNer pores aM MrvcMea TM ConlraMer rMl b MM � n, �n„ n., w< eMatlr�axa� ,ro,�nw,lertnbb<a�na.11ew�rmepw Ad Im., pwr ro.n o.nvemn TM urornp corro,<1or a,ax uae,nb pomOYy M aM con .wwr.e e« ro earraPO of »b uNrtws Can Bt l Boron v« Dq 2 W not nxNrlly poceoa +.N cwarucmn as a »qua wsn X a Demos m.l er pan ellererw.s e, W tMt rraY M Mva ban rn eureq «rgn Srcn aMmwr aMY b enrM4Mry brorrpld b IM son al Wr W «MI GOMraaw arM QMr(a Rep.e.rX.be TM Unesc.q Cenbcror rbn..vbr ler n,prmXaYty Ip ar news »ry remmnr eu. b IeMAe b 9^'e wcn «Mwalwn Y X OMecs. err» ben sae el aMSS eM pans. f A — 1 l. DoroMOI ro nMaa wls RepanM,M1ro or Fa resoWwn rlre a rtbae wch ceHach b N. Omroyf Repe »Malrve wall resW m COm.UOya bbMy le robceY melerb4 1 TM lArMec1« Connor Lr1 mMy Or 1. R..--- n —1 pmr b nmrrnwmeM a nol4 ro oowearab po1M mspsUbn xheeu4e 5 TM lepwee KrNbnq ae0 ro Ld 1 Me .Yearly ban appwaa eM peWP41.e b.aaoaelbn orbs G» Ne. MSI l-0Z 6 LaMSUb Cenleper.Mr peHi pw VM cosh M every s¢e a p4M 1, arM tY Iy« b nr.e orX « Pbrdaq Pbns UrM na Ie rncbMS tlr pbM rrvroMl tlrebbe mcaMap s1 bbr, «wpnM ewnrrorda. 4MNan. .M aMr rrrlanb ea aYtl.e rp.cMe for estlr s¢e r n Xr LAMan» CoMMCbYe rsspensidMy b Mnen pbM mebsah h» a N. U r i»sca« Cwn.cfw.rl0 b <erMIW�Wa1�ra Me.» w N N� b L.Mxap GOMrecloh OWgbon b eernMy a0 pan ma1Mb1 M hw ye.n rows Rral eccaparms 8 L.MU.» Cwmecmr MaY b n.penr-0b br.rry norJnaMn van wbcwn.aon as repm.a ro accwrrearr plaMaq op. atom a m.mMq ra.a era bona br of p4MS sea Iw MBPer sqn «alr .. uMe br «sate to An pan marorol ,wan b ..am,ebe ro «arerl <wnenon, ror n.aMa,r a e monWn taws do Mnp 11 oae�n sn aRrnrrlNMlawbry anMn oln » »..od hom.n a.a.Xba,od, ar IM mn >acbn ooM TM analys4.IW early sb »E.Biry a Xr n v r .+ l o bdr ,n.l rr..wq.a bah...rle r.Pen.nm.eebon,l , w r�wnnn b be aPenleX Ae alenel arr.r rar.a. »n mrrrM a by KweZl »rrgM e11Y b b Xre ah. LonBOn b Ea M bl.mir.X N'tlre Wmr a RepeaarbXM. TIr eor arAMrrroM. ameply ep T U It y W b Xr mvn.mpd , CO a W 3- 120 w SS— rrvar»y SW T—,,, lab A]i &NESB. Port Con. C BM211120 w erns Mp6Mf Yh IZ WM nma, are abbevabe on baweps. 5 «p4M bifw 4.Y arM tlaafd.AdN 13 sMl lora6ar a al pan rnl 1a hM Abp1 to Ne aW.-el Ns Dme Rapro»nbim la Apply A orbs Yards al orgrac nr 0 pr 1.000 rRUar. leel b 10 soU»e W. a Beene b«, Is b<or«Mro arr.rwroMr NwouXnry.Mn by B m a rod rota d.q .rrrnena ro+ m rmbn pMe. ate eb.wwnr ,noY.n on m.mrga oe rw1 nwa »da MMer rrob.t w mMey rmMlsm 18 A--sal ar»MrrMr 8 MIOrgnc, E — a Ts 3 '.150 )B WCR Eet« CO C 80815 Nvl lSa)191 17 Do rot cwmerrca arraMeq a e.nhrq »d par ro acnpanu .1 1 Xnb 18 AY pam.q dw areas one Iree panteya oval renna a man,.n a r a mrKn TM coMraUOr n Mapnsrble Iw we« corns on ber aM s «be anaa uqY ImM poleU acnparce IS Tr« peMne, era raerrrq pMa eY b ba.me xNl1 Oware bnrpbM /Tr«sl art. O.nea bee sap IPbnL.rp bhl Mcwrhv..mocv4Mr maNee.t tlro rate r.<onnnMbe W M m.raX.cMer 20 Sae ea. ds for panlvq repb.merda. maomh.aM eaecuMn 21 S—Gey an noes »preeba for• Panoeaoro year 2z. r erwMN era »«fre « prom. Ns bne.cap coneaer n 10 wbml A W a aomYy evade64 anwuh ro b uree to IM OwneYa Repre »nMtn br appov.l 23 G— corer areas era m M esrgaarry ,pane. uaasr o0rrwse snexm er nose «roe plans 21 Ar... yes »merrb awn or. .rper.y a<ns »a sNrMmam urobbrrroe arM luny aocesvW .brq New ends letph la rreebn.m eM emergncy .wnprrM aM voncba 25 CeMra <rorn rospomr.lerr«Iwaap aX Mlurbe brleuep areas arse .»em8 env mr.eeoa nrgabn nrroorrMf .rra'w Mrer<,» w•aq areas ep. ro nnrewwt.atM LANDSCAPE NOTES I ALL LANDSCAPE BEDS TO RECENE r DEPTH OF DECORATNE ROC. OR Y MULCH Z ALLTURFAREAS TOM IRRIGATEDWRNAN AUTOMATIC POP UP ANOOR ROTOR SPRINKLER SYSTEM 3 ALL PLANTING BEDS TO BE IRRIGATEDMATH AN AUTOMATIC DRIP IRRGATON SYSTEM A ALL IRRIGATION TOM CONTROLLED MATH AN AUTOMATIC IRRIGATON CONTROLLER WOTH RAIN SENSORS c 9 �m W d� 2 ' w ^ H V Z LLI J a S Cw7 2 0. S o F or Z l Z fr 5w a z w Q z U 3 N o Z Q ARCHITECT ENGINEER LANDSCAPE ARCHTECT eo�oo`s s.rF' -o� w�irA, gin pout .H wmr<+e K F P H ART � T M n � 0 ' v L FREp ar[bra BWB COMB. RRLT�NA 5of5 8000 South Uncoln Street, #206 Littleton, CO 80122 Otrim (72M 283-6783 1 wwwredland,com n9i aces 1 Based on a landscaped area of 12,773 square feet, building coverage (roof area) of 20,997 square feet and hardscape/pavement area of 26,540 square feet, the proposed apartment project will have an impervious percentage of 75.2% which is less than the assumed 83% value that was utilized within the above referenced report, W6 Tr TT ♦ • design flow and W-M" FISMM r • WMI detention impacts as was used in the original evaluation. Since the actual site configuration represents a lower impervious coverage, the calculations for runoff will yield a slightly more conservative result. This analysis is therefore in compliance with the original design intent. » »« w< MOTI "> « «« i W jl kyll A g K#lw I I f-. 111 M##E gtm � \ anal ii Current Criteria teria ------------- Tributary area ac \3 /\��].. Percent Imperviou 22 / # X 80. ---i \ \� \2 �� \ \\ \� \ \\ \ \ \�� \ * { \ \ ILYA # # ��1� \ \ » »« w< MOTI "> « «« i W jl kyll A g K#lw I I f-. 111 M##E gtm ZEDLANf) ago 100 year event release shall be controlled as an orifice release on the proposed 24" outlet pipe, A plate shall be installed over the proposed pipe restricting the release rate to 6.9 CfS. The headwater depth operating the orifice is 7.73 feet requiring an opening area of 0.83 0.26 implying the d/D = 0.3, For a 24" pipe the plat must be set 7.2 inches above the pipe invert • control the major event release. Maintenance of the detention facility shall be administered through the property owner. An agreement is being developed for lots 1, 2 and 3 of the Wheat Ridge Town center subdivision addressing maintenance responsibility and required compensation. 'Volume (incremental) ��. IP! � IMI f� � {' � I w �� U. ����IVIII�. ♦ �. �. y { II � IM��� IlI • e Ir III M II 100 year event release shall be controlled as an orifice release on the proposed 24" outlet pipe, A plate shall be installed over the proposed pipe restricting the release rate to 6.9 CfS. The headwater depth operating the orifice is 7.73 feet requiring an opening area of 0.83 0.26 implying the d/D = 0.3, For a 24" pipe the plat must be set 7.2 inches above the pipe invert • control the major event release. Maintenance of the detention facility shall be administered through the property owner. An agreement is being developed for lots 1, 2 and 3 of the Wheat Ridge Town center subdivision addressing maintenance responsibility and required compensation. K= Rick Rome, P.E. DESMAN AR�AI, 3 ��70SF AT 100% Sll E ARI 1, IIS 110,11111Ci CII-RA- W,' SP A! W% w t1 m SF -1 RUNOFF COEFFICIENTS - DEVELOPED PROJECT NAME: PROJECT NUMBER: CALCULATED BY: 7/23/2014 CHECKED BY: Note: Runoff coefficients shown were obtained from UD &FCD Criteria Manual Equations LAND USE Residentail Density assumes 55% from RO -3 IMPERVIOUSNESS DESIGN BASIN DFSIGN POINT TOTAL AREA (AC) % IMP Group A Group CD Group B Ca 5 Ca 10 Ca 100 Ccd 5 Ccd 10 Ccd 100 Cb 5 Cb 10 Cb 100 43rd Ave 1 0.38 83% 0.60 0.63 069 0.65 0.69 0.76 0.63 0.66 0.73 Lot 2 2 2.22 75% 0.50 054 0.61 0.57 0.61 0.70 0.54 0 58 0.66 West Lot 3 3 0.47 90% 1 0.71 0.73 0.79 0.74 0.77 0.83 072 0,75 0.81 East Lot 3 4 2.30 89% 0.69 0.72 0.77 0.73 0.76 0.82 0.71 074 039 South Vance 5 0.65 84% 0.62 0.65 1 0.70 0.67 0.70 0.77 0.64 0.67 0.74 North Vance 6 0.28 84% 0.62 0.65 0.70 0.67 0.70 0.77 0.64 067 034 Lot 1 7 1.37 83% 0.60 0.63 069 0.65 0.69 0.76 0.63 066 0.73 U han SW 8 0.31 55% 033 0.38 047 0.42 0.48 0.61 0.38 043 0.54 44th Ave SW 9 0.12 55% 033 0.38 047 0.42 0.48 0.61 0.38 0.43 0.54 C0�11'OSII'1 8.10 1 81 5% 1 059 0.63 0 69 0 65 0 68 0 76 0.62 0.65 0.72 SUBTOTAL 5.4 19.925512 Ca= Ka +(1.31i 1.44i +1.135i -0.12)or0 Cb = Kcd+0.85i' -0.78i'+0.774i+0.04) Cb = (Ca+Ccd)R PEN STANDARD FORM SF -2 - DEVELOPED ' Time of Concentration PROJECT NAME: Wheatridge Town Center Lot I DATF 7/23/2014 PROJECT NUMBER: 11014 CALCULATED BY: RAR CHECKED BY: FT SUB -BASIN DATA INITIAL TIME (T TRAVEL. TIME (T,) tc CHECK (URBANIZED BASINS) FINAL tc DESIGN BASIN ( AREA Ac ( C 5 (3) LENGTH Ft (4) SLOPE % (5) T ; Min. (6) LENGTH Ft. ( SLOPE % (8) C, (9) band Surface ( VEI, fps (11) T, Min. (12) COMP. tc ( TOTAL LENGTH (14) te= (U180) +10 Min. ( 1 5) Min. ('S ('10 Cloo 43rd Ave 0.38 0.65 30 2.0% 3.6 120 2.0% 20.0 Paved Areas 2.8 0.7 4.3 150 10.8 5.0 0.65 0.69 0.76 Lot 2 2.22 0.57 50 2.0% 5.4 250 2.0% 20.0 Paved Areas 2.8 1.5 6.9 300 11.7 6.9 0.57 0.61 0.70 West Lot 3 0.47 0.74 30 2.0% 2.9 400 2.0% 20.0 Paved Areas 2.8 2.4 5.2 430 12.4 5.2 0.74 0.77 0.83 East Lot 3 2.30 0.73 30 2.0% 3.0 390 2.0% 20.0 Paved Areas 2.8 2.3 5.3 420 12.3 5.3 0.73 0.76 0.82 South Vance 0.65 0.67 50 2.0% 4.5 400 2.0% 20.0 Paved Areas 2.8 2.4 6.8 450 12.5 6.8 0.67 0.70 0.77 North Vance 0.28 0.67 50 2.0% 4.5 180 10% 20.0 Paved Areas 2.8 1.1 5.5 230 11.3 5.5 0.67 0.70 0.77 Lot 1 1.37 0.65 50 2.0% 4.6 200 2.0% 20.0 Paved Areas 2.8 1.2 5.8 250 11.4 5.8 0.65 0.69 0.76 U han SW 0.31 0.42 20 2.0% 4.4 400 2.0% 20.0 Paved Areas 2.8 24 6.8 420 12.3 6.8 0.42 0.48 0.61 44th Ave SW 0.36 0.42 30 2.0% 5.4 300 2.0% 20.0 Paved Areas 2.8 1.8 7.2 330 11.8 7.2 042 0.48 0.61 11014 -Lot 1_SF2 -3 Forms Page 2 of 4 [Zk ND 43rd Ave 1 038 STANDARD FORM SF -3 - DEVELOPED 2 Lot 2 2.22 0.57 ' West Lot 3 STORM DRAINAGE DESIGN - RATIONAL METHOD 5 YEAR EVENT East Lot 3 2.30 PROJECT NAME: Wheatridge Town Center Lot I 5 South Vance 065 0.67 DATE: 7,23 2014 PROJECT NUMBER: 11014 1 0.67 7 P, (1 -Hour Rainfall)- 1.45 1137 0.65 8 U han SW 031 CALCULATED BY RAR 9 44th Ave SW 0.36 1 0.42 CHECKED BY FT DIRECT RUNOFF TOTAL RUNOFF STREET PIPE TRAVEL. TIME REMARKS zy`U C7 W Ow v c C y v V S d zF V OJ w �Q OCR zW E Q O'4 E `� m e `yam Oa pe 0 RO OJa aN z E > (1) (2) (3) (4) (5) (6) (7) (8) 1 (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) (21► (22) 1 43rd Ave 1 038 0.65 2 Lot 2 2.22 0.57 3 West Lot 3 047 0.14 4 East Lot 3 2.30 0.73 5 South Vance 065 0.67 6 North Vance 1 0.28 1 0.67 7 Lot 1 1137 0.65 8 U han SW 031 0.42 9 44th Ave SW 0.36 1 0.42 50 025 1 4.92 1 12 6.9 127 4,48 5 7 5.2 0 35 4.86 1 7 5 3 1 67 4.85 8 1 68 0.43 4.49 1.9 5.5 0.19 4.79 0.9 5.8 0.90 473 42 61 0.13 4.51 0.6 7.2 0.15 1 4.43 0.7 Sum this evaluation 69 35 1 3.48 ?02 Sum Previous Evaluation 6.62 44 1 4 54 20.0 00 VA • i DEVELOPED PROJECT NAME: Wheatridge Town Centet Lot I DATE 7/23/2014 CHECKE STORM DRAINAGE DESIGN - RATIONAL METHOD 100 VEAR EVENT PROJECT NUMBER 11014 P (]-Hour Rainfall). 2.75 : D IRECT I DETENTION VOLUME BY THE MODIFIED FAA METHOD I Project: Wheatridge Town Center North Lot 1 Basin ID: 2014 Criteria Comparison (For catchinem ks Joss than 160 acres onl F or larger catchments, use hydrograph routing method) t .OiE for catchments larger than 90 acres, CUHP hydrograph and routing are recommended) Determination of ..,. -,: Detention Volume Using Modified FAA Method Determination of MAJOR Detention Volume Using Modified FAA Method Catchment Drainage Impemouane.a I, - 79 70 percent Catchment Dra e g tna Imrvi psoutness I, = 79.70 percent m Catchent Drainage Area A - 6 920 acres Catchment Drainage Ara. A. 6.920 area Predevaiopmenl NRCS Sal Group Type = C A, S, C, or D Praderelopnwlt NRCS Soil Group Type = C A, 8, C. or D Return Penrod for Detention Control T = 5 yeah 12, 5. 10. 25, 50, or 100) Return Period for Detention Control T = 100 years (2, 5. 10, 25, 50, or 100) Time of Ca�centratwn or Watershed Tc = 14 minute. Nipw able Una Raw. Rate q = 0 17 cf&1 re Time of Concentration of Watershed Tc = 14 minutes Allowable Una Release Rate q = r 1 dsl.cra One -hour Precipitation P, = 1 0.5 inches pr,a.npur prep pdainn P, = 2.75 inches Dee n Rainfall IDF Formats I ` C, P Desi i+lc.•TJ "Cs Dnlgn Rainfall IDF Formula 1 . C, Pdlcr'TJ "Cn Coafiaent One C, = 9 50 • Coaff. -rit One C1 • 28,50 Coeftiunt Two C _ 10 Coaft...nt Two C s 10 - Coal Three C = 0 789 Cceffldent Three Ca • 0.789 Determination of Average OutR7w t he Basin (Calculatedl: Determination of Averace Outflow from the Basin (C41liadvileft Runoff Coefficient C = 0.02 Runoff Coeffuaent C = 014 Inn- Peak Runoff Op-In : 14049 de Inflow Peak Runoff Op+n a 32.81 do Allowable Peak Outflow Rate Op -out = 1.18 afa Allowable Peak Outflow Rate Op-out = 6.82 Ch Mod. FAA Minor Storage Volume • 23,800 cuiflc Oar Mod. FAA Myrn Storage Volume • 35,823 culic Mt Mod. FAA Minor Storage V.I. • 0.6M Sol" Mod. FAA Major Storage Vokrme a OA22 act" 5 "It. Ramtsu Wlatwr. 11 11 " value Here le a 5 to }Minutes Rainfall Inflow Adjustment Average outflow, Sto Remfall Rainfall inflow AdjulM nM Average Outflow' Srore Duration intensity i Volume Fads Outflow Volume Volume Duration imena4y VoWme Fedor O Volume VoWme rlanutes r acraJeat 9tr d. eC,94*W acra4aet malutes inches I hr scra4eet 'rr Ole ataa4est ac.4-1: t W (output 0 000 - 0.000 - 0.00 0.00 0.000 0.000 0 0.00 0.000 0.00 0.00 0.000 0.000 5 _ 4 6a - 0.144 1.00 1.18 all" 0.138 5 9.26 _. 0.326 1.00 0.02 0.002 1 0.270 10 - 3 99 0.230 1.00 1.18 _ 0.016 0.214 10 7.37 0.520 _ 0.92 0.005 0.425 15 3.26 111,289 0.08 1.13 0.023 0.266 /5 618 0.054 _100 0.96 6.87 0.138 0.510 20 282 0.334 0.86 1.00 0.077 0.306 20 6.36 0.765 0.85 -- 0.06 01162 01661 25 2.60 0.300 1 0.78 0.92 0.032 0.338 1 25 4.74 0.830 0.78 5.38 0.105 aill 30 2.25 0.300 0.73 0.80 0.030 0.383 30 4.27 0.903 0.73 5.00 0.209 maim 35 105 0,424 0.70 0.62 0.040 0.381 35 3.89 0.900 0.70 4.03 0.233 11 727 40 1.89 0.44e 0067 11 0.044 0.402 40 3.58 1.010 0.67 4.06 0.257 0.753 M 1.76 0.485 0.85 0.77 0.018 0.418 45 3.32 1.054 0.85 4.63 0.201 0.773 5o 1.83 0.483 0.64 0.75 0.052 0.431 50 3.10 1.003 0.61 1642 0.305 0.788 56 1.53 0.490 _ 0.63 Ill 0.069 0.443 56 2.91 1.129 0.63 133 0.326 awo 8o 1.02 0.513 002 0.72 0.080 0.463 02 2.74 1.101 0.02 4.26 0.352 0.800 as 1.37 0.520 oat 0.71 01084 0.402 as 2.00 1.191 0.61 4.20 0.376 0.815 70 110 Mae 0.60 0.70 0.088 0.171 70 1 2.47 1.210 1 a 4.15 0.400 0.820 75 1,24 a560 0.50 - 59 0.70 0.072 0.11a 75 2.35 1245 M50 4.10 0.424 0.822 80 1.79 0.561 0. am a076 0.486 40 225 1.270 0.59 4.00 0.440 0.022 40 1.14 0.571 0.58 0.80. 1 0.060 0.491 45 2+6 207 199 0.50 4.03 0.1'71 0.822 90 1.00 O.S81 0.58 0.06 0.084 0.407 90 _ 1315 1. 335 _ 1 355 1.374 1.392 1._100 _ _1125 1.111 0.58 3.00 0.195 0.620 06 1.05 0.500 0.67 0.67 1 0.068 0.802 96 0.67 3.97 0.510 0.616 100 1.01 0.500 0.57 0.87 0.002 0.500 100 _ __ 1.92 0.67 3. W 0.543 0.612 106 0.08 0.007 0.67 0.87 0.806 0.511 105 1 BS 1.79 0.57 3.92 11.507 0.807 110 0.95 0.815 as$ 0.06 atoll 0.514 110 0.56 3.00 0.590 0.801 115 0.02 0 -Ma 0.56 aa0 0.104 0.618 115 7.71 0.50 3' as 0.011 0.794 120 0.80 0.630 0.56 0.06 0.108 0.621 120 1.68 0.50 3.66 0.038 0.767 125 0.60 O637 am ads 0.113 0.524 125 _ - 1.63 0.50 1 3.64 0.052 0.770 130 0.64 0.043 0.55 0.85 0.117 0.527 1 130 1.50 1.460 0.55 3.83 0.680 0770 135 0.01 0.850 0.66 0.05 0.121 0.520 135 1464 1.471 6.56 3.02 0.710 0.761 140 0.79 O.e" 0.55 0.85 0.126 0.531 140 1.50 1.485 am 3.60 0.733 0.752 145 0.77 0.002 0.55 0.64 0.129 _0_533 iM 1.409 0.55 3.79 0.767 0.742 100 0.75 0.868 0.56 0.61 0.133 0.635 150 _1.47 1.43 1.512 0.55 3.70 0.761 0.731 156 0.74 0.674 0.51 1 0.84 0.137 0.537 155 1.40 1.11 0.54 3.77 laws all" 100 M72 0679 0.54 - 0.84 0.111 aWS too 1.38 1.536 0.54 3.70 &am 0.709 166 0.70 0885 0.51 0.64 0.145 0.540 185 1.33 1.560 0.51 3.76 0.863 0.097 170 0.00 0 690 _ 0.5/_ _ 0.64 0149 0.541 170 1.30 1102 0.6/ 3.74 Man 0.05 175 0.67 _ 0 695 054 0.63 0.153 1 0.542 175 1.27 1.573 1 0.54 3.73 11000 0.873 100 am 0 700 054 - - - 0.03 0157 1 0.543 180 125 1.566 0.64 3.73 0.924 0.000 185 0.54 0 705 054 463 0.161 0.602 186 122 1.006 0.64 3.72 0.019 am too 0.83 0 710 0 51 - 0.03 0.165 0.544 100 1.20 LOW 0.54 3.71 0.972 0.696 195 0.02 0 714 054 - 0.63 0.109 0.616 195 1.18 1.617 as$ 371 0.998 0.021 200 0.61 0 719 0 53 0.63 0.773 0.615 2DO 1.15 1.0.27 0.53 3.70 1.019 am$ 205 0.00 0 723 0.53 0.83 0.177 0.548 205 1.13 1.637 0.53 3.09 1.043 0.594 210 0.50 0 727 0.53 0.69 stet 01640. 210 1.11 1.647 0.53 369 1.007 01580 215 0.58 0 732 1 .53 _ 0.03 _ 0.185 0.540 215 1.09 1.660 0.53 3.68 1.001 0.1105 220 0.57 0.730 0.53 0.03 0.100 0.540 220 1.07 1.aaa 0.89 3.60 1.116 Ill 225 0.56 x740 0.53 0.02 0.194 ante 1 225 1.00 1.675 0.63 347 1.139 as" 230 0.66 0.741 0.53 0.02 0.190 0.540 230 1.04 1.064 0.53 3.87 1.182 0.622 235 0.54 O.74111, 0.83 0.02 0.202 0.546 236 1.02 1.803 a63 380 1.186 0.507 240 0.53 0.752 0.53 0.62 0200 0.540 240 1.01 1.701 a53 168 1.210 0.491 245 0.52 am 0.53 0.62 0.210 0.546 245 a99 1.710 0.53 3.0.6 1234 0.476 250 0.51 0.759 0.53 0.62 0.214 0.545 251) 0.97 1.718 0.63 3.02 1258 0.461 2S5 0.01 0.763 0.63 0.02 0.218 0.5413 255 0.96 1.727 0.63 3.66 1.202 1 0.445 260 0.50 01769 0.63 0.62 1 0.222 0.544 200 _ 095 1.736 0.53 3.64 1.305 0.429 2813 0.40 0.770 0.53 0.52 0.220 0.644 20.5 093 1.743 0.53 302 1.329 0.413 270 0.40 0773 1 0.53 0.02 0.230 0.513 a 270 092 -- 1.750 0.63 3.64 1.353 0.397 275 0.48 am 0.53 &112 a234 0.643 275 09t t.758 0.53 3.63 1.377 0.361 280 0.47 0790 0.52 0.02 0.239 6542 -_ 290 . - 0.60 1.706 0.52 363 1.401 0.306 215 0.47 0 783 0.02 0.82 _ 0.212 0.541 _ 285 0.86 1.773 0.62 3.69 1.425 0.349 290 0.40 0787 0.52 . 082_ _ 0.246 _ 0.540 0.67 1780 0.52 3.83 1.028 0.332 296 0.46 0 790 6s2 062 0.787 0 52 082 0.250 0 539 0.251 0 539 _290 295 t 786 1 795 1.172 0.316 0.86 0.40 0.02 0.52 312 _ 3 82 300 .M 300 1.196 __..._ 6666 _. ___._ _ 6.6_66._ ___.___ 6666 •.1a., .w,•yv vv,unw lcrrc rN` w,Ya Mod. FAA Minor Storage V.I.- Irre - fl.) ` 0.5464 Mod. FAA Major Storage Volume (aer*4) a CAM UDFCD DETENTION BASIN VOLUME ESTIMATING WORKBOOK Version 2.34, Released November 2013 Copy of UD-0elsnhon v2 34, Modaiee FAA - 702/2011,1:37 PM STAGE - DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET Project' Basin ID: WOCV Design Volume Ilnput, 0.371 sstenfwM - het Water Ouaery Capture Volm e (WOCA. Catchment enpervoushess. 4 = 60,0 Percent Calash" Area. A 0.92 Total opererg area at each row based on userrJfyuf aEM. Ad = Depth at WOCV outlet above lowest Perforation, H = 2 feet Vertical distance between rows, h = 4.00 inches Number of rows . 1 = 5,00 Onlioe dscharpe ooefticiert, C = D.W m Slope of Bass, TrOde Chae4 S 0,0W Trine to (Nan the Pon = 40 hours Watershed Deslon Information farorr0- = 111 boil TyPe A = % Percent Soil Type B = % Percent Sot Type CID = 100 % D—ler of roles, D = 1.202 urcnes Number of holes Per row. N = 1 Hegm of slot. H = inches W dth of slot. W = inches Water Ouasty Capture VoMane, WOCV= 0.371 sstenfwM - het Water Ouaery Capture Volm e (WOCA. 0,211 wrs4 t es Dlpn Volume lWOCV 112' Aroa' 1A Vol . 0267 mrFlset Outlet area per row, Ad = 1.13 square inches Total opererg area at each row based on userrJfyuf aEM. Ad = 1.13 square inches Total opereng area at each row based on userfpr i seas. Ao = 0 square feet 0 0 0 0 0 0 0 0 0 0 0 O 0 0 o O e Perforated Pla te Examples 0 F-H -0 I � 4 t7verrlde Owfrrtb Owxrltle Ossrtlda Ovarrk Area Area Atea Ama Aroa Row Row Row Rmua Rr..,r Copy of UD DeteMnn V2.34, WOCV 71212014, 1:37 PM —m ® ®�— __-------- �_ - - - - -� _� ®s..af.>•.a1.1 .ill•- -- ----- ------ -- - - -® Emm glum — ® ®m=m ® ® -- ------ - - - - -- - - -® MEMO — � ® ® ®mrim--- -------- — ® ®MEMM ® ®— _-- _-- --— - - - - -- s.=mr"m® ® ®-- _— _ ------— _--- _ — _� ®_ ��_ lumm - -® —m + ® OWA MA —_ _ — ®�' t'!R�f'?R�f'!7� �� l� � ���saassssrasasasaarsa t7verrlde Owfrrtb Owxrltle Ossrtlda Ovarrk Area Area Atea Ama Aroa Row Row Row Rmua Rr..,r Copy of UD DeteMnn V2.34, WOCV 71212014, 1:37 PM STAGE - STORAGE SIZING FOR DETENTION BASINS Project: Basin ID: am sire s4e z * Fl.. M6 sip z L p.. sae su z A n- w --------- __L ----- siiesiwz Design Information (lnout): Width of Basin Bottom, W = 39.00 ft Length of Basin Bottom. L = 136.00 ft Dam Side -slope (H:V), 4 = 99.00 fiffl err sy.. pe. nw WIC � ai Eleee L Check Basin Shane Right Triangle OR... Isosceles Triangle OR... Rectangle OR... Circle / Ellipse OR... Irregular (Use Overide values in cells G32.G52) MINOR MAJOR Storage Requirement from Sheet'Modified FAA': 0.55 0.82 acre ft. Stage-Storage Relationship: Storage Requirement from Sheet'Hydrograph': acre -ft. Storage Requirement from Sheet 'Full-Spectrum': acre -ft, Labels for WQCV, Minor. 8 Major Storage Stages r;n nrt: Water Surface Elevation ft ( input) Side Slope (H:V) Wit Below El. nnrnnt Basin Width at Stage ft ( output) Basin Length at Stage ft (output) Surface Area at Stage ft ut Surface Area at Stage ft? User Overide Volume Below Stage ft (output) Surface Area at Stage acres ( Volume Below Stage acre -ft (output) Target Voiumes for WQCV, Minor, 8 Major Storage Volumes for goal seek 5400.20 39.00 136.00 5,303 0 0.122 0.000 WQCV 5401.20 5402.20 5402.20 540120 0.00 0.00 0.00 0.00 0.00 0.00 15,909 21,212 7,955 21,212 39,773 0.243 0.365 0.487 0.183 0.487 0.913 0.257 100 + WQCV 5404.20 0.00 0.00 26,515 63,636 0.809 1.481 1.227 5405.20 0.00 0.00 31,818 92,803 0.730 2.130 5406.20 0.00 0.00 37,121 127,272 0.852 2.922 5407.20 0.00 0.00 42,424 167,045 0.974 3.835 5408.20 1 0.00 1 0.00 47,727 212,120 1.096 4.870 5409.20 0.00 0.00 53,030 262,499 1.217 6.026 #WA #N/A #WA #tN/A #N/A #N/A #WA #N/A #N/A #NIA #N /A #N/A #N/A #N/A •N/A #N/A #N /A #WA MA #WA #N /A #WA #N/A #WA WA #MUA *N/A MWA #NIA #N/A #WA #N/A #WA #N/A #N/A #WA *N/A #WA MA #N/A MWA #N/A #lN/A #N/A #WA MA *N/A #WA #N/A #WA #WA #WA MA *N/A #WA #WA MA MA #WA #N/A #WA #N/A #N/A #WA #WA #N/A #WA #WA Copy of UD- Detention v2.34, Basin - 7/21/2014, 1:37 PM Izi DtANn Wheat Ridge Town Center Lot 1 Pipe Worksheet 12/3/2014 Sidi Element From (inlet) To (Outlet) Length Inlet Outlet Average Pipe Manning's Entrance Exit/Bend Peak Max Design Reported ID Node Node Invert Invert Slope Diameter Roughness Losses Losses Flow Flow Flow Condition Elevation Elevation or Height Velocity Capacity (ft) (ft) (it) N (inches) (cls) (ft/sec) (ds) 1 Link-02 Inlet-Cl MH-2 21.19 5404,60 5403.90 33000 18 0.0150 0.50 0,50 17.67 10.86 16,55 SURCHARGED 2 P-1 MH-3 Pond 28A5 540130 5401.05 0.8900 36 0.0120 0.20 0.20 6211 10.96 68.10 Calculated 3 P-10 EXIN6 MH-1 47.22 5403,80 5402.SO 2.7SO0 24 0.0120 0.50 O.SO 8,76 1032 40.66 Calculated 4 P-11 18 EXIN6 118.84 5408,10 5403.80 3.6200 24 0.0130 0.50 0,50 8.76 10.80 4103 Calculated S P-12 17 18 4239 5408.59 5408.11 1.1300 24 0.0130 0.50 0,50 8.88 7.16 24.07 Calculated 6 P-13 16 17 202,43 5411.27 5408.69 11700 18 0Z130 0.50 0.50 9.28 8.14 11.86 Calculated 7 P-14 ERIN -S 16 91,12 5412.23 5411.37 0.9400 18 0,0130 0.50 0.50 10.21 8,45 10.21 SURCHARGED 8 P-IS EXIN-4 EXIN-5 20.66 5412.60 541233 13100 18 0.0130 0.50 O.SO 9.32 1168 12,01 Calculated 9 P-16 ln1etC3 Pond-Inlet 2.97 5407.10 5406.80 10-1100 18 0.0120 0.50 0.50 20.64 21.09 3619 Calculated 10 P-17 POND Out -1 89.87 S400.20 5399.56 0.7100 18 0.0130 0,50 O.SO &86 12.53 8.86 SURCHARGED 11 P-2 MH-1 MH-3 44.64 5402.00 5401.50 1,1200 36 0.0120 010 010 61.95 12.13 76.47 Calculated 12 P-3 MH-2 MH-1 3159 5402.70 5402.20 1A900 30 0.0130 0.50 0,50 5169 11.85 50.05 SURCHARGED 13 P-4 MH-3a MH-2 2510 5403,29 5402.90 1.5500 30 0,0130 0.50 0.50 34.66 11.18 51.03 Calculated 14 P-5 STM MH-3a 174,46 5405.17 5403.45 0.9900 30 0.0130 0.50 0.50 34,60 10.38 40.73 Calculated 15 P-6 IN-Lot STM 72.78 5406,62 5405.47 1.5800 24 0.0120 O.So 0.50 24.98 11.45 30,81 Calculated 16 P-7 IN V2 STM 32.11 5405.88 5405.47 1.2800 18 0.0130 0.50 0.50 11.50 7.83 11,87 Calculated 17 P-8 IN-V1 IN 33.24 5406.65 5406.18 1,4100 18 0,0130 0.50 0,50 12,49 14,11 12,49 SURCHARGED 18 P-9 Inlet-C2 MH-2 733 5404.10 5403.90 23300 18 0.0130 0.50 0,50 18,63 1115 17.35 SURCHARGED N D Wheat Ridge Town Center North Lot 1 12/3/2014 Outlet Worksheet �M�o Gofto ftces sro" Std Element X Coordinate Y Coordinate Invert Boundary Flap Fixed Peak Maximum Maximum ID Elevation Type Gate Water Inflow FILL Depth HGL Elevation Elevation Attained Attained (ft) (cfs) (ft) (ft) 1 Out- I 119071.86 708300.34 5399.56 NORMAL NO 8.86 1.50 5401.06 2 Pond 119336.81 708277.27 5401.05 FIXED NO 5407.90 62.11 2.25 5403.30 3 Pond 119288,70 708309,67 5406.80 FIXED NO 5407.90 20.64 0S1 5407.61 Wheat Ridge Town CEnter North Lot 1 Hydraulic Analysis 12/3/2014 SN Element X Coordinate Y Coordinate Catchbasin Max Max Initial Peak Peak ID Invert (Rim) (Rim) Water Flow Lateral Elevation Elevation Offset Elevation Inflow (ft) (ft) (ft) (ft) (ds) (cfs) 1 EXIN-4 119251.21 707832,47 5412.60 5415.73 3.13 5412.60 1.00 1.00 2 EXIN-5 119251.10 707853.13 5412,23 5415.75 3.52 541213 1.70 1.70 3 E71IN6 119382.89 708200.42 5403.80 5411,16 7.36 5403.80 0.00 0.00 4 IN !t2 119102.64 708260.96 5405.88 5408.43 2.55 5405.88 2J11 210 5 Inlet-Cl 119313.95 708212.17 5404,60 5410,30 5.70 0.00 13.30 13.30 6 Inlet-C2 119315.75 708243.60 5404.10 541037 6.27 5405.00 9.40 9.40 7 InletC13 119293.02 708309.71 5407.10 5410.65 3.55 5407.10 3.00 3.00 8 IN-Lot 119043.14 708229.60 5406.62 5410.08 146 5406.62 17.30 17,30 9 IN-V1 119069.40 708260.49 5406.65 5408.90 2.25 5406.65 2.20 2.20 10 POND - OUTLET 119161.73 708300.66 5400.20 5412.17 11.97 5400.20 6.90 6.90 E F)LAND Wheat Ridge Town Center Lot 1 12/3/2014 Junction Worksheet wNw cmwt Xxvt &' g in SN Element Invert Ground/Rim Ground/Rim Initial Minimum Peak Maximum Maximum Minimum Average Average ID Elevation (Max) (Max) Water Pipe Cover Infl ow HGL HGL Freeboard HGL HGL Elevation Offset Elevation Elevation Depth Attained Elevation Depth Attained Attained Attained Attained N (ft) N (ft) (inches) (cfs) N N N N N 1 16 5411.27 5416.80 5.53 5411.27 47.16 10,21 541187 1.60 193 5412.56 1.29 2 17 5408.59 5414.87 618 5408.59 51.40 918 5409.69 1.10 5.18 5409.62 1.03 3 18 5408.10 5414.14 6.04 5408.10 48.36 8,88 5408.95 0.85 5.19 5408.92 0.82 4 MH-1 5402.00 5411.40 9.40 5402,00 76.80 62.36 5404.70 230 630 540412 2.22 5 MH-2 5402.70 5410.44 7.74 5403.20 60.48 62.12 5410.44 7.74 0,00 5408-18 5.48 6 NIH-3 540130 5411.42 10,12 5401.46 83.04 61.95 5403.55 2.25 7.87 5403.39 2.09 7 MH-3a 5403.29 5410,59 7.30 5403.25 55.68 34.60 5405.22 1.93 537 5404.85 1.56 8 STM 5405,17 5410.60 5.43 5405.17 35.10 36,48 5407.02 1.85 158 5406.58 1.41