Loading...
HomeMy WebLinkAbout5660 W. 38th Avenue, Unit Bi CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: AU3 t,_t - Job Address: �5(c(/)o UJ. �,AAm Are " 64 Permit Number: 220 � 7 0:2& I A ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes (No) When corrections have been made, call for re-iT in t303-234-5933 Date: �-1 1 Inspector:�� f DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Solar PERMIT - 201707614 PERMIT NO: 201707614 ISSUED: 09/28/2017 JOB ADDRESS: 5660 W 38th AVE UNIT B EXPIRES: 09/28/2018 JOB DESCRIPTION: Permit for remove/reinstall existing system (see 201401235) 3.0 KW Roof mounted grid tied PV system. *** CONTACTS *** OWNER (303)707-4422 NT PERRINS LLC SUB (888)765-2489 Jared A Miller *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: 2946 / MANSFIELD 110035 SolarCity Corporation USE: UA / Unassigned BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,080.00 FEES Total Valuation 0.00 Use Tax 85.68 Permit Fee 125.05 ** TOTAL ** 210.73 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do her attest that the work to be performed shall comply with all accompanyinapproved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am t e legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. 1 further attest that 1 arti.leggaII authorized to include all entities named within this doaiment as parties to the work to be performed andihat all work to be perfprmed is disclosed in this document and/or its' accompanying approved plans and specifications. i_AU Signature of OWNER or CONTRACTOR (Circle one) Date I J 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3• If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4• No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulaf this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date V REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of WheatP j, COMMUNITY DEVELOPMENT �q ge Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: 6 f Z_'51 1 —1 Plan/Permit # LA Plan Review Fee: *** Building Permit Application �2 Please l� complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 5660 W 38th Ave Unit B, Wheat Ridge, CO 80212 Property Owner (please print): Misti Piering Phone_25&- 61 Property Owner Email: 9-7 A 1 —S-9 0g Mailing Address: (if different than property address) Address: Same as above Citv, State, Z Architect/Engineer: Architect/Engineer E-mail: Contractor: Solar City Contractors City License M 110035 Contractor E-mail Address: tward@SolarCity.COCYI Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: 253-720-4461 Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT x OTHER (Describe) R&R Solar PV (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) R&R a 3 kW roof -mounted grid -tied solar PV system Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $4080 OWNER/CON'CRACTOR SIGNA'T'URE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this aJ. cation; that I am the Legal owner or have been authorized by the legal owner of the property to perform the described work and am also authq#Ired by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OW.VER) (CONTRACTOR) or (AUTHORIZED REPRESENTATI�,'E) of PRINT NAME: Tyler Ward ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: SIGNATURE: DEPARTMENT USE ONLY PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required (CONTRACTOR)WI DATE: 9/22/2017 OCCUPANCY CLASSIFICATION: Building Division Valuation: $ ABBREVIATIONS ELECTRICAL NOTES INDEX «yc" Jicive Mw c tR LICENSE A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET PV2 SITE PLAN APPROVED AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS ReviewedforCodeCom B ance CONC CONCRETE OF THE HAZARDS PER ART. 690.17, PV4 STRUCTURAL VIEWS TYPE EC # 8041 C D COMBINER BOX DISTRIBUTION PANEL 2. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV5 THREE LINE DIAGRAM PV5 ELECTRICAL DIAGRACALCULM PER CUTSHELEC ATTACHED DC DIRECT CURRENT BY PHASE AND SYSTEM ART. 210.5. - ` EGC EQUIPMENT GROUNDING CONDUCTOR 3. A NATIONALLY -RECOGNIZED TESTING- - - Plans fzarnwer i Date (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. 4. CIRCUITS OVER GROUND SHALL Thi s,�nreoloa.n,no< •ndton J �o IWosped%coffins pu(aton shall not heopermt p or en q any vlototon G GALV SOLAR GUARD METER GALVANIZED T. 5 COMPLY WITH ART. 250.97, 250.92(6) to nnyolihepoiveasoltArytowakto*«ce,,e pobnon �wm fe c,.rbeAe"V ansolthee,,;idr„y JURISDICTION NOTES GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER codes or orMr ordmonres of the Crry sAoR nor be rntid or,,_tAoruftk_Ctysh GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 1. THIS SYSTEM IS GRID-INTERTIED VIA A kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE UL -LISTED POWER -CONDITIONING INVERTER. kW KILOWATT UL -LISTED LOCATION PROVIDED BY THE 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. This permit is for the remove/reinstall of LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 3, PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND MIN MINIMUM HARDWARE. INVERTER INPUT CIRCUIT ARE UNGROUNDED. Existing equipment previ fitted on MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 5. ALL WORK TO BE DONE TO 2009 INTERNATIONAL 201401235 ONLY CnyOt NEC NATIONAL ELECTRIC CODE UL LISTED LAY -IN LUGS LISTED FOR THE BUILDING CODE. Whe at NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE Rin►,._ NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED 2011 NATIONAL ELECTRIC CODE. g�JJdiu OC ON CENTER RAIL. ngal�Json P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL, PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(B) & 690.47. cn SS STAINLESS STEEL SSD SEE STRUCTURAL DRAWINGS' S'tr� Rd, STC STANDARD TESTING CONDITIONS c, SWH SOLAR WATER HEATER o Walmart TYP TYPICAL Supercenter IHOP LION UNLESS OTHERWISE NOTED in UPS UNINTERRUPTIBLE POWER SUPPLY Super 8 Denver w Famous Dave's V VOLT Stapleton LegenlM Hit Vmp VOLTAGE AT MAX POWER Bar-6-Gue Voc VOLTAGE AT OPEN CIRCUIT W WATT E 35tlh Ave ' 3R NEMA 3R, RAINTIGHT I. ither Kara Jr Blvc Q REV BY DATE COMMENTS Niartin ! usher Ki -1g Jr !fit W 0 'K7 CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT USED FOR THE JOB NUMBER: J B— 8024752 0 0 PREMISE OWNER: AHJ: Wheat Ridge DESCRIPTION: DETTMAN, CHRISTIAN NEW TOWN BUILDERS PERRINS ROW CO DESIGN: NIRA NISCH AL �\`�,. c • cOla�("I+" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., E NOR SHALL IT RE DISCLOSED IN WHOLE OR IN MARKET: N. HOMES MODULES: 12 CANADIAN SOLAR CS6P-250PX 56608 W 38TH AVE. LOT 7. 3.OKW DC ROOF MOUNT PV SYSTEM �'•• J �• 1. r® PART IZ OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH WHEATRIDGE CO 80212 � PROJECT MANAGER: MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM PAGE NAME: SHEET: 3055 Clearview Way San Mateo, CA REV: PATE; 94402 PAYMENT TYPE: LEASE INVERTER 1(1) POWER -ONE # AURORA PVI-3.0-OUTD SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. s61��11068 COVER SHEET PV T:(650)638-1028 F:(650)638-1029 1 8/15/2014 (888)-SOL-CM(765-2489)www.solarcity.com 85' TRENCH 18" DEEP CONDUIT: 1" SCH. 40 PVC WITH WARNING RIBBON 6" BELOW GRADE 1.61 % VOLTAGE DROP OTHER PV INSTALLATION AREA STAMPED AND SIGNED FOR STRUCTURAL ONLY Digitally signed by Srihari Raghavan Date: 2014.08.18 23:02:50 -07'00' mit!•° •� �� �`�� ftN P►\., PITCH: 12 ARRAY PITCH: 12 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shinqle STORY: Above LEGEND 0 (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DISCONNECT & WARNING LABELS FAC I AC DISCONNECT & WARNING LABELS O JUNCTION BOX M DC COMBINER BOX & WARNING DISTRIBUTION PANEL & WARNING Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE - - - INTERIOR EQUIPMENT SITE PLAN Scale: 3/32" = 1' 01, 10' 21' S 3 M N CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JIM NUMBER: JB -8024752 00 PREMISE OWNER: AHk. Wheat Ridge DESCRIPTION: DETTMAN CHRISTIAN NEW TOWN BUILDERS PERRINS ROW CO DESIGN: NIRAJ NISCHAL BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN MARKET: N. HOMES MODULES: 12 CANADIAN SOLAR CS6P-250PX 56608 W 38TH AVE. LOT 7. 3.OKW DC ROOF MOUNT PV SYSTEM ',, SolarC•�ty. PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH WH E A TR I D G E CO 80212 PROJECT MANAGER MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM 3055 Cleamew Way San Mateo, CA 94402 SOLARCITY EWIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME: S61�7A1068 SITE PLAN SHEET REV: PATE T:(650) 638-1028 F:(650) 638-1029 PV 2 8/15/2014 (888)-SOL-CITY(765-2489)www.solarcity.com PAYMENT TYPE: LEASE INVERTER: (1) POWER—ONE # AURORA PVI-3.0—OUTD Stories 4' MAX. BETWEEN FOOTINGS STAGGERED 7 PV MODULE STANDOFF CScale: 1-1/2" = 1' ZEP LEVELING FOOT HANGER BOLT (6) (4) 2' TYP ECOFASTEN FLASHING (N) ZEP INTERLOCK (E) COMP. SHINGLE � (E) 2x4 RAFTERS (3) ® 24" SPACING FRONT VIEW OF MP1 (E) ROOF DECKING BA"x4" LAG BOLT (1) Scale: 1/2"=1'-O" (2-" EMBED, MIN) (2) (5) (E) RAFTER LOWEST MODULE STAMPED AND SIGNED FOR STRUCTURAL ONLY Digitally signed by Srihari Raghavan Date: 2014.08.18 23:03:03 -07'00' CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -8024752 00 MARKET: I MODULES: PROJECT MANAGER: MATTHEW BRIGGS PAYMENT TYPE: (12) CANADIAN SOLAR # CS6P-250PX MOUNTING SYSTEM: SOLARCITY SLEEKMOUNT SYSTEM GRADE -1-1 COMPACTED BACKFILL � 6 LLJ 8" � o w U � z czn °O N — 3X JV UJL y�V LIY 1 IYIVUVLLJ UNDISTURBED SOIL RED WARNING TAPE W/ TRACE WIRE APPROVED BACKFILL SCHEDULE 40 PVC CONDUIT D TRENCH DETAIL Scale. 3/4 - 1-0 IEMISE OWNER: AHJ: Wheat Ridge DESCRIPTION: DESIGN: DETTMAN, CHRISTIAN NEW TOWN BUILDERS PERRINS ROW CO NIRAJ NISCHAL 5660B W 38TH AVE. LOT 7. 3.00 DC ROOF MOUNT PV SYSTEM WHEATRIDGE, CO 80212 POWER -ONE # AURORA PVI-3.0-OUTD+S61�7A1068 PAGE NAME: STRUCTURAL VIEWS SHEET: REV: PV 3 INSTALLATION ORDER (1) LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT ECOFASTEN FLASHING. (4) PLACE FLASHING BLOCK. (5) NSTALL LAG BOLT WITH SEALIN WASHER. G(6)INSTALL LEVELING FOOT WITH WASHER AND NUT. '=SolarCity. 1 3055 Clearview Way San Mateo, CA DATE 94402 T:(650) 638-1028 F:(650) 638-1029 8/15/2014 (888) -SOL -CITY (765-2489) www.solarcity.com STAMPED AND SIGNED Digitally signed by Srihari Raghavan Date: 2014.08.18 23:03:13 -07'00' City of Wheat Ridge uilding CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. :;! I 2o-¢ I� 1i JOB NUMBER: JB -8024752 00 MARKET: MODULES: N. HOMES 12 CANADIAN SOLAR # CS6P-250PX PROJECT MANAGER: MOUNTING SYSTEM: MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM PAYMENT TYPE: INVERTER: OWER -ONE # AURORA PVI -3.0 -OU SIDE VIEW OF MP T. CHORD: 2x6 ® 24" O.C. A SUPPORT: 2X4 WEBS, LBW SCALE: 1/4" = 1' MAX SPAN: 7'-0" 0AISEOWNER: AHF. Wheat Ridge DETTMAN, CHRISTIAN 5660B W 38TH AVE. LOT 7 WHEATRIDGE, CO 80212 S61�7A1068 (E) 2X6 TOP CHORD (E) 2X4 WEBS (E) 2X4 BOTTOM CHORD DESCRIPTION: DESIGN. NEW TOWN BUILDERS PERRINS ROW CO NIRAJ NISCHAL 3.OKW DC ROOF MOUNT PV SYSTEM PAGE NAME: STRUCTURAL VIEWS SHEET: REV: PV 4 ; SolarCity � u� 1 1 3055 Clearview Way San Mateo, CA DATE 94402 T:(650) 638-1028 F:(650) 638-1029 8/15/2014 (888) -SOL -CITY (765-2489) www.solarcRy.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) UFER AT PANEL (E) 400A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1 (1) POWER-ONE /INVERTER RA PV1 2.0- g6 S -US -Z -A LABEL: A -(12)CANADIAN SOLAR CS6P-250PX TYPE EC # 8041 WITH IRREVERSIBLE CRIMP E 400A LPN -R FUSED MAIN DISCONNECT Zigbee PV Module; 250W, 229.6W PTC, 40mm, Black Frame, MC4, ZEP Enabled INV 2 Panel Number: Meter Number: Voc: 37.2 Vpmax: 30.1 INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER Distribution Panel s ADJUST MIN. ACTIVATION VOLTAGES! SolorCity B, MILBANK CUTLER -HAMMER Inverter 1 PAR ::A] - Meter Socket Disconnects 4 POWER -ONE DC, DO NOT ADJUST MIN. ACTIVATION V TAGE ��I AURORA PVI-3.0-OUTD-S-US-Z-A Dc- S[ring(s) Of 6 On MP 1 100A/2P 20A/2P C D - - EGC z1. r ------- ------------------- J L1 jD s I L2 I TO (E) N 3 I 2 EGC DC+ DC+ DO NOT ADJUST MIN. ACTIVATION V TACE _ _ _ _ _ _ _ DISTIBUTION f— CCNU PANEL _ - - - - - - - - - - - GND GND - - - - - - - - - - - - - - - - N DC- DC_ 1 String(s) Of 6 On MP 1All UNIT r---------- --—-----------—-----------—------- - - - - — - GEC --- GND EGC—-—-----------—-- - - - - -- - - -EGC- ---------- -----J OOA/2P I e (1 ) Conduit Kit; 3/4" EMT N I TO (E) DISTIBUTION PANEL I UNIT B I I OOA/2P I II II e N I TO E DISTIBUTION PANEL I I UNIT C I I I OOA/2P I , a I N I I TO (E) I DISTIBUTION PANEL UNIT D I I I I I I _ J I E f1EC O I I I 4QOA FUSED _ _ GECI DISCONNECT ,#8 JUMPER n [� (t)SIEMENS SERIES - A NEM/ 3R: W0816ML1 1 25CU n � Load Center; 125A, 120 240V, NEMA 3 /-� A (t) SolarCityyg 4 STRING JUNCTION BOX 2x2 STRMGS, UNFUSED, GROUNDED D� I (1 )MILBANK # U4801 -XL -5T9 Meter Socket; 200A, C Ringless TO 120/240V BOND (N) 18 EGC/GEC TO (E) #6-350, -(3)MILBANK # K4977 -INT YvhEl SINGLE PHASE UFER OR (E) GEC IN Load -Side Tap Connector; 100A, y12 - 1/0 AWG UTILITY SERVICE PANEL WITH IRREVERSIBLE (1)CUTLER-HAMMER 'ja;�9 9e CRIMP PER ART. 250.64(C) () scorn 40Vac, N I I Disconnect; 30A, 240Vac, Non -Fusible, NEMA 3R � o - (1)CUTLER-HAMMER ! DG030NB Ground/Neutral 30A, General Duty SOn it; (DG) - ( 1) Wire _._ - - ----- --- — --Metal-Clad_Cable:-�� �w/G-75degC - -- -- 1 ()SIEMENS Q220 PV BACKFEED BREAKER POI Breaker �2OA/2P. 2 Spaces (t )AWG #10, THWN-2, Black -( 1) AWG j6, Solid Bare Copper GEC 3 cin (1) AWG #10, THWN-2, Red O Or (1) AWG $10, THWN-2, Black Voc* = 181.46 VDC Isc =8,87 ADC (2) AWG #10, PV WIRE, Block 3 (1) AWG /10, THWN-2, Red Vmp =1806 VDC Imp= 8.3 ADC O (1 ) AWG 110, Solid Bare Copper EGC O Voc* = 181.46 VDC Isc = 8.87 ADC Vmp = 180.6 VDC Imp= 8.3 ADC (1 )AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 AAC PF(1)AWG L J IIII -(l)AWG #10, THWN-2, Green EGC - ( 1) Conduit Kit; 1" PVC, Sch. 40 EGC (1 ) AWG #10, THWN-2, Green EGC 2 (2) AWG /10, PV WIRE, Black O Isz+� (1 ) AWG /10, Solid Bare Copper EGC Voc* = 181.46 VDC Isc = 8.87 ADC Vmp = 180.6 VDC Imp= 8,3 ADC - ( 1) Wire ILJJ Metal Clad Cable; MC 10/3 w/G 7 e C or c* = 181.46 VDC Isc = 8.87 ADC ® (i) AWG /10, THWN-2, Black Vmp = 180.6 VDC Imp= 8.3 ADC _ (1) AWG ,#10; THWN-2; Red -(I)AWG /10, THWN-2, Green EGC CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER J B-8024752 00 PREMISE OWMER: AHJ: Wheat Ridge PREMISE DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BENEFIT Of ANYONE EXCEPT SOLARCITY INC., DETTMAN, CHRISTIAN NEW TOWN BUILDERS PERRINS ROW CO NISCHAL •} .�_ 'SQlaf �� `y .ro� �'A MARKET: MODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN N. HOMES 12 CANADIAN SOLAR CS6P-250PX 5660B W 38TH AVE. LOT 7. 3.OKW DC ROOF MOUNT PV SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH WHEATRIDGE CO 80212 PROJECT MANAGER: MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM 3055 Clearview Way San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. S6l�9 7A1068 PAGE NAME: THREE LINE DIAGRAM SHEET: REV: DATE: PV 5 8/15/2014 T:(650) 638-1028 F:(650) 638-1029 (888)-SOL-CTTY(765-2489) www.solarcity.com PAYMENT TYPE: LEASE INVERTER: (1) POWER -ONE # AURORA PVI-3.0-01LITD 1. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All string terminations are rated at 90' C. ------------------------------------------ 2. OCP Sizing per Art 690.8(8)(1) a. Round up to next size per Art 240.4(8) ------------------------------------------- 3. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(8)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All branch terminations are rated at 75' C min. ------------------------------------------ 4. OCP Sizing a. Round up to next size per Art 240.4(B) ------------------------------------------ 5. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must hove (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All inverter output terminations are rated at 75' C. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CnYof , 6. OCP Sizing a. Round up to next size per Art 240.4(B) WV eat Ridge 7. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All inverter output terminations are rated at 75' C min. CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB -8024752 00 CONTAINED SHALL NOT BE USED FOR THE Imp) * MARKET: MODULES: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN N. HOMES 12 CANADIAN SOLAR # CS6P-250PX PART TO OTHERS OUTSIDE THE RECIPIENT'S PROJECT MANAGER: MOUNTING SYSTEM: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER: PERMISSION OF SOLARCITY INC. LEASE (1) POWER -ONE # AURORA PVI -3.0-01-1 ELECTRICAL CALCULATIONS Module: 12 Canadian Solar CS6P-25OPX-BF 227.6 Inv Power I WPTC Inverter 1: 1 Power -One PVI -3.0-S AFCI 0.96 3300 2621.95 Module: Inverter 2: Module: Inverter 3: Module: Inverter 4: Total: 12 Modules Photovoltaic Module Electrical Specifications: Voc: 37.2 V Vmp: 30.1 V Isc: 8.87 A Imp: 8.3 A Tvoc: 0.12648 V/deg C Tisc: 5.85 mA/deg C String Type A and 2 Combined Strings Type A Power -One PVI -3.0-S AFCI 6 Canadian Solar CS6P SOPX BF Voc= 223.2 Vmp= 180.6 Isc= 8.87 Imp= 8.3 Icont= 11.09 1.a Conductor: I AWG_10 Total Inv Pwr: 3300 1262195 PTC Total STC: 3000 deg F deg C Record Low Temp: -22 -30 Max Average Hi Temp. 89 32 Record Hi Temp: 95 135 Art 690.8(A)(1 PV Wire Voc Correction Method: Manuf Tvoc data Voc Correction Factor: Imp) * 2 * Length) * Resistance / Vmp) Inverter Min Vdc Input: 120 Imp (A) Min Vmp at Max Temp: 161.9 40 Max Voc at Min Temp: 181.46 15 AWG_10 Inverter Max Vdc Input: 600 Vdrop = Max String Size: 19 161.90016 1 -way wire length: 1 15 1 8.3 Voltage Drop Calculations Version 5_8.0 Vdrop = Imp) * 2 * Length) * Resistance / Vmp) Icont * 1.25 = (Amps) 30 deg C ampacity = 1.b Icont= (Amps) Imp (A) Max. Length (ft) Wire Start ampacity 40 String: 1 8.3 15 AWG_10 at Max Ave Hi:89 Vdrop = 8.3 * 30 * 0.001240hms / 161.90016 0.19 Branch: 1 8.3 50 1 AWG_10 at Max Ave Hi:89 Vdrop = (8.3 * 100 * 0.001240hms) / 161.90016 0.64 Ampacity Total voltage drop in DC conductors = 0.83 Inverter: 1 8.3 95 1 AWG_10 j at 240V Vdrop = (8.3 * 190 * 0.0012 Ohms / 240 V 0.7885 Combined: 0 1 0 1 AWG_10 at 240V Vdrop = (0 * 0 0.0012 Ohms) / 240 V 0 Total voltage drop in AC conductors = 0.79 Total voltage drop in AC and DC conductors = 1.61 Branch Circuit Type A 1 strings per branch 1 6 modules per series string Voc= 223.2 V Vmp= 180.6 V Isc= 8.87 A Imp= 8.3 A Icont= 11.09 A 2.a Conductor 1: AWG_10 Conductor 2: AWG 10 Icont * 1.25 = (Amps) 13.86 13.86 30 deg C ampacity = 401 Icont * 1.25 = (Amps) 30 deg C ampacity = 1.b Icont= (Amps) 11.09 2.b Icont= (Amps) Start ampacity 40 Temperature derate (%=F) 0.76 Start ampacity Conduit fill derate (%=#) 1 Temperature derate (%=F) Derated ampacity 30.4 Conduit fill derate Derated amoacity 1.c Start ampacity Icont * 1.25 = (Amps) 13.86 Ampacity 40 1.d Icont * 1.25 = (Amps) 13.86 OCP Size = Inverter Type A Output Power -One PVI -3.0-S AFCI Icont = 14.5 1 A 3.a Icont * 1.25 = (Amps) 0.76 OCP Size = 3.b Conductor: AWG_10 24.321 Icont * 1.25 = (Amps) Term 1 Term 2 75degC75degC 30 deg C ampacity = 3.c Icont = (Amps) 35 Start ampacity Temperature derate (%=F) Conduit fill derate Derated ampacity 3.d Icont * 1.25 = (Amps) Ampacity PREMISE OWNER: AHJ: Wheat Ridge DETTMAN, CHRISTIAN 5660B W 38TH AVE. LOT WHEATRIDGE, CO 80212 S61�L�7A1068 13.86 15 1 way wire length: 85 ft Art 690.8(A)(1) 18.12 Art690.8(B)(1) 20 Art 240.6(A) THWN-2 at 90 deg C: Table 310.16 18.12 40 14.5 40 0.91 1 36.4 18.12 2.c Temp table Icont*1.25= (Amps) Ampacity deg F deg F 1 way wire length: 50 1 strings per branch 2 6 modules per series string Voc= 223.2 V Vmp= 180.6 V Isc= 8.87 A Imp= 8.3 A Icont= 11.09 A Art 690.8(A)(1 PV Wire PV Wire Conductor Conductor 13.86 13.86 40 40 11.09 11.09 40 40 0.76 0.76 0.8 0.8 24.321 24.32 Term 1 Term 2 75degC75degC 13.86 13.86 351 35 2.d OCP Size = 1 15 1 15 Combined Inverter Output Service Voltage= Total Inverter Power= Icont = # of inverters*max inverter current Icont = (Amps) 4.a Icont*1.25 = (Amps) 18.12 OCP size = 20 4.b Conductor: AWG_10 TH Icont * 1.25 = (Amps) 18 30 deg C ampacity = 4.c Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate Derated ampacity 4.d Icont * 1.25 = (Amps) 1 1 way wire length= Art 690.8(A)(1) Art 690.8(B)(1) Art 240.6(A) WN -2 at 90 deg C: Table 310.16 .12 40 14.5 40 0.91 1 36.4 8.12 35 DESCRIPTION: DESIGN: NEW TOWN BUILDERS PERRINS ROW CO NIRAJ NISCHAL 7. 3.OKW DC ROOF MOUNT PV SYSTEM PAGE NAME: ELECTRICAL CALCULATIONS SHEET: REV: PV 6 0 =.wi,SolarCity. 3055 Clearview Way San Mateo, CA DATE: 94402 T:(650) 638-1028 R(650) 638-1029 8/15/2014 (888)-SOL-CrrY (765-2489) www.solarcity.com Lardjag Escrow AgMement This agreement made this 28'h day of April, 2015, by and between the City of Wheat I i Aei rKS111111A11112 MUM 5660 W. 38 1h Avenue In the event that landscaping is not installed by June 1, 2015, the City of Wheat Ridge or its designee shall have the right to enter upon said property to construct and/or install such improvements or do other such work to accomplish that purpose as may be necessary, provided that the City of Wheat Ridge shall first give notice in writing to the property owner of its intent to do so. If the City of Wheat Ridge exercises its right to perforin work of any nature, including labor, materials and use of equipment either by force account or contract, the City shall have the absolute right to withdraw the escrow funds to complete said improvements, The only precondition to the City's right to withdraw the funds for this purpose shall be a letter from the Community Development Director, stating that the improvements have not been completed or provided and that the compliance date of June 1., 2015, has expired. M= nm Business Address / Phone Date rMte Cill of Wheat Rida, Colorado By - Title: Date:— City of' Escrow/Letter of Credit LLd91 Transmittal Sheet jiq� 1111111111111111! 1 located at 5660 W. 38hAvenue. The escrow is in the amount of Thrdl The above amount is to be held in escrow for: E Other: Escrow expires June 1, 2015 The escrow shall be held by the City as reimbursement to offset cost to City for installation of outstanding landscaping and paving improvements. z Name Date lu ♦� City of " jjgic COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033 -8001 P: 303.235.2846 F: 303.235.2857 February 26, 2015 OFFICIAL ADDRESS NOTIFICATION NOTIFICATION is hereby given that the following address has been assigned to the property /properties as indicated below: PROPERTY OWNER(S): NT Perrins LLC NEW ADDRESS: Wheat Ridge, CO 80212 Lot 1 — 5690 W. 38' Ave., Unit D Lot 2 — 5690 W. 38 Ave., Unit C Lot 3 — 5690 W. 38' Ave., Unit B Lot 4 — 5690 W. 38 Ave., Unit A Lot 5 — 5660 W. 38" Ave., Unit D Lot 6 — 5660 W. 38 Ave., Unit C Lot 7 — 5660 W. 38' Ave., Unit B Lot 8 — 5660 W. 38' Ave., Unit A Lot 9 — 5630 W. 38 Ave., Unit D Lot 10 — 5630 W. 38 Ave., Unit C Lot 11— 5630 W. 38' Ave., Unit B Lot 12 — 5630 W. 38 Ave., Unit A Lot 13 — 3795 Depew St., Unit D SUBDIVISION: Perrins Row Filing No. 2 Jefferson County Reception Number for Plat: 2013143669 AUTHORIZED BY: DISTRIBUTION: Lot 14 - 3795 Depew St., Unit C Lot 15 — 3795 Depew St., Unit B Lot 16 — 3795 Depew St., Unit A Lot 17 — 3791 Depew St., Unit A Lot 18 — 3785 Depew St., Unit B Lot 19 — 3785 Depew St., Unit A Lot 20 — 3781 Depew St., Unit A Lot 21— 3781 Depew St., Unit B Lot 22 — 3781 Depew St., Unit C Lot 23 — 3781 Depew St., Unit D Lot 24 — 3791 Depew St., Unit D Lot 25 — 3791 Depew St., Unit C Lot 26 — 3791 Depew St., Unit B DATE: 2 — Z 5 - - / 5 1. Jefferson County Assessor, ATTN: Data Control, 100 Jefferson County Parkway, Golden, 80419 2. Jefferson County Mapping, ATTN: Addressing, 100 Jefferson County Parkway, Golden, 80419 3. Jefferson County Elections, ATTN: H. Roth, 3500 Illinois Ave., Laramie Building, Suite 1100, Golden, CO 80401 4. Email to Jeffco IT Services at smitchel(a�jeffco.us 5. U.S. Post Office, 3700 Tennyson St., Denver, CO 80212 6. Email to erlinda j.martinez@ sps.g and krissv.i.summerfield(a usps.gov 7. Xcel Energy, ATTN: Correspondence, 1123 W. 3rd Ave., Denver, CO 80223 8. Century Link, Capacity Provisioning Specialist, 5325 Zuni St., Room 728, Denver, CO 80221 9. Comcast, Attn: Scott Moore, 6850 S. Tucson Way, Englewood, CO 80112 10. Wheat Ridge Water District 11. Wheat Ridge Sanitation District 12. Wheat Ridge Fire District 13. Wheat Ridge Planning Division 14. Wheat Ridge Building Division www.d.wheatridge.co.us 15. Wheat Ridge Police Department 16. GIS Specialist 17. Log File NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: Vicinity May DATE: Nk