HomeMy WebLinkAbout5660 W. 38th Avenue, Unit Ci CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office - (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: J 03 Ir1r1. ti �e (- V_F:_�-'&
Job Address: I
Permit Number: 901_)07:a)�9
❑ No one available for inspection. ime %� AM/PM
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303-234-5933
Date: L(Cl % Inspector: 11144
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge
Residential Solar PERMIT - 201707709
PERMIT NO: 201707709 ISSUED: 09/26/2017
JOB ADDRESS: 5660 W 38th AVE UNIT C EXPIRES: 09/26/2018
JOB DESCRIPTION: Permit for remove/reinstall existing system (see 201401236) 3.0 KW Roof
mounted grid tied PV system
*** CONTACTS ***
OWNER (303)707-4422 NT PERRINS LLC
SUB (888)765-2489 Jared A Miller
110035 SolarCity Corporation
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2946 / MANSFIELD BLOCK/LOT#: /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,080.00
FEES
Total Valuation 0.00
Use Tax 85.68
Permit Fee 125.05
** TOTAL ** 210.73
*** COMMENTS ***
*** CONDITIONS ***
Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am tie legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
thisermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompa ing approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4, No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
T _ a C
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of
Wheat P ridge
COMMUNITY DEVELOPMENT
Building & Inspection Services Division
7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
FOR OFFICE USE ONLY
Date:
Plan/Permit #
101-10.1-1
Plan Review Fee:
Building Permit Application � I <:),-]
— Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ***
Property Address:
C
5660 W 38th Ave Unit 4, Wheat Ridge, CO 80212
Property Owner (please print): MW824W''` jl-fc,4 �iAPhone— ��
Property Owner Email: ._� <:::) 3 9 9 S " / W '�'
Mailing Address: (if different than property address)
Address: Same as above
City, State
Architect/Engineer:
Architect/Engineer E-mail:
Contractor. Solar City
Contractors City License #:
110035
Contractor E-mail Address: tward@SOlarCity.COnl
Sub Contractors:
Electrical:
W.R. City License #
Other City Licensed Sub:
City License #
Plumbing.
W.R. City License #
Phone:
Phone: 253-720-4461
Other City Licensed Sub:
City License #
Mechanical:
W.R. City License #
Complete all information on BOTH sides of this form
LoWclz3b 30
Description of work: (Check all that apply)
❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE
❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING
❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING
❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT
❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT
aELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
X OTHER (Describe) R&R Solar PV
(For ALL projects, please provide a detailed description of work to be performed, including current use of areas,
proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and
amount of materials to be used, etc.)
R&R a 3 kW roof -mounted grid -tied solar PV system
Sq. FULF
Amps
Btu's
Squares
Gallons
Other
Project Value: (Contract value or the cost of all materials and labor included in the entire project)
$4080
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application.
CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (O
PRINT NAME: Tyler Ward
ZONING COMMMENTS:
Reviewer:
BUILDING DEPARTMENT COMMENTS:
Reviewer:
PUBLIC WORKS COMMENTS:
Reviewer:
PROOF OF SUBMISSION FORMS
Fire Department ❑ Received
Water District ❑ Received
Sanitation District ❑ Received
SIGNATURE:
DEPARTMENT USE ONLY
❑ Not Required
❑ Not Required
❑ Not Required
(CONTRACTOR)W
DATE: 9/21/2017
OCCUPANCY CLASSIFICATION:
Building Division Valuation: $
ABBREVIATIONS
ELECTRICAL NOTES
INDEX
City of
LICENSE
AMPERE
1. WHERE ALL TERMINALS OF THE DISCONNECTING
PV1
COVER SHEET
ALTERNATING CURRENT
MEANS MAY BE ENERGIZED IN THE OPEN
PV2
SITE PLAN
APPROVED
BLDG
BL
BUILDING
POSITION, A SIGN WILL BE PROVIDED WARNING
PV3
STRUCTURAL VIEWS
Cop��
for Code m
CONC
CONCRETE
OF THE HAZARDS PER ART. 690.17.
PV4
STRUCTURAL VIEWS
Reviewed
TYPE EC # 8041
C
D
COMBINER BOX
DISTRIBUTION PANEL
2. EACH UNGROUNDED CONDUCTOR OF THE
MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED
PV5
PV6
THREE LINE DIAGRAM
ELECTRICAL CALCULATIONS
CUTSHEETS
ATTACHED
DC
DIRECT CURRENT
BY PHASE AND SYSTEM PER ART. 210.5.
t910
EGC
EQUIPMENT GROUNDING CONDUCTOR14�
3. A NATIONALLY -RECOGNIZED TESTING
Date
(E)
EXISTING
LABORATORY SHALL LIST ALL EQUIPMENT IN
{H.l"s Exanniner
EMT
ELECTRICAL METALLIC TUBING
COMPLIANCE WITH ART. 110.3.
4. CIRCUITS OVER 250V TO GROUND SHALL
vpalmnAnw�Su,cor,oe,o-'rato •o�orok�otiw*
cno-sshO)I otbeape--(I-.oranoOOOW OL O�y "'9
G
GALV
SOLAR GUARD METER
GALVANIZED
COMPLY WITH ART. 250.97, 250.92(8)
o,dc
uwo/tAeprovrvo"so/MeDs"i6"O�cwcf Cbardrw+eesM
•� �"1din°
JURISDICTION NOTES
GEC
GROUNDING ELECTRODE CONDUCTOR
5. DC CONDUCTORS EITHER DO NOT ENTER
codes a oMer arr!"+a"ces of rhe Ciry sAoll not be yoAd.
C'M0,ohe,Wem�WWtogiveouthor ofrtwCtysjo*nfW evoAd.
GND
GROUND
BUILDING OR ARE RUN IN METALLIC RACEWAYS
GENERAL NOTES
HDG
HOT DIPPED GALVANIZED
OR ENCLOSURES TO THE FIRST ACCESSIBLE DC
I
CURRENT
DISCONNECTING MEANS PER ART. 690.31(E).
Imp
CURRENT AT MAX POWER
6. ALL WIRES SHALL BE PROVIDED WITH STRAIN
INVS
INVERTERS
RELIEF AT ALL ENTRY INTO BOXES AS
Isc
SHORT CIRCUIT CURRENT
REQUIRED BY UL LISTING.
1.
THIS SYSTEM IS GRID-INTERTIED VIA A
kVA
KILOVOLT AMPERE
7. MODULE FRAMES SHALL BE GROUNDED AT THE
UL -LISTED POWER -CONDITIONING INVERTER.
kW
KILOWATT
UL -LISTED LOCATION PROVIDED BY THE
2.
THIS SYSTEM HAS NO BATTERIES, NO UPS.
This permit is for the remove/re-install of
LBW
LOAD BEARING WALL
MANUFACTURER USING UL LISTED GROUNDING
3.
PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND
MIN
MINIMUM
HARDWARE.
INVERTER INPUT CIRCUIT ARE UNGROUNDED.
Existing equipment previously permitted on
MIR
MIRROR
8. ALL EXPOSED METAL PARTS (MODULE FRAMES,
4.
SOLAR MOUNTING FRAMES ARE TO BE GROUNDED
(N)
NEW
RAIL, BOXES, ETC.) SHALL BE GROUNDED USING
5.
ALL WORK TO BE DONE TO 2009 INTERNATIONAL
201Da)
NEC
NATIONAL ELECTRIC CODE
UL LISTED LAY -IN LUGS LISTED FOR THE
BUILDING CODE.
NIC
NOT IN CONTRACT
PURPOSE. POSTS SHALL BE MADE
6.
ALL ELECTRICAL WORK SHALL COMPLY WITH THE
NTS
NOT TO SCALE
ELECTRICALLY CONTINUOUS WITH ATTACHED
2011 NATIONAL ELECTRIC CODE.
OC
ON CENTER
RAIL.
P
PANEL BOARD
9. MODULE FRAMES, RAIL, AND POSTS SHALL BE
PL
PROPERTY LINES
BONDED WITH EQUIPMENT GROUND CONDUCTORS
PV
PHOTOVOLTAIC
AND GROUNDED AT THE MAIN ELECTRIC PANEL.
PVC
POLYVINYL CHLORIDE
10. THE DC GROUNDING ELECTRODE CONDUCTOR
VICINITY
MAP
S
SUBPANEL
SHALL BE SIZED ACCORDING TO ART.
SCH
SCHEDULE
250.166(B) & 690.47.
vQ
SS
STAINLESS STEEL
;z
SSD
SEE STRUCTURAL DRAWINGS
c; Smirb nB
STC
STANDARD TESTING CONDITIONS
SWH
SOLAR WATER HEATER
o WalmarT .
TYP
TYPICAL
5upercent�r
!I♦4R
UON
UNLESS OTHERWISE NOTED
UPS
UNINTERRUPTIBLE POWER SUPPLY
Super 8 Denver,� Famous Dave's
V
VOLT
Staplelon Legendary Pit
Vmp
VOLTAGE AT MAX POWER
fear-S-Que
Voc
VOLTAGE AT OPEN CIRCUIT
t
W
WATT
3R
NEMA 3R, RAINTIGHTP
r:e
Luther <Mg Jr P1Yc:
�
REV BY DATE COMMENTS
rt
4
z
Nid f- Li0her Wing; Jr ?I
s * x x
c
F �
CONFIDENTIAL – THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
JOB NUMBER: JB -8024824
00
PREMISE OWNER:
PAOLUCCI,
AHJ: Wheat Ridge DESCRIPTION:
ANDREA NEW TOWN
BUILDERS PERRINS ROW CO
DESIGN:
NIRAJ NISCHAL
MARKET:
N. HOMES
MODULES:
12 CANADIAN SOLAR CS6P-250PX
NORBENESHALLL IT OF T BE DISCLOSED SOLARCITYYONE EXCEPT HOLE ORCIN
5660C W
38TH AVE. LOT 6. 3.00 DC
ROOF MOUNT PV SYSTEM
'i�,SolarCity.
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH
WHEAT RIDGE CO 80212
�
PROJECT MANAGER:
MOUNTING SYSTEM:
THE SALE AND USE OF THE RESPECTIVE
MATTHEW BRIGGS
SOLARCITY SLEEKMOUNT SYSTEM
3055 Clearview Way San Mateo, CA
9+402
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
PAGE NAME:
COVER SHEET
SHEET:
PV
REV: PATE: T:(650)638-1028 F:(650) 638-1029
1 8/19/2014 (888)-SOL-CRY(765-2489) www.solarcfty.com
PAYMENT TYPE:
LEASE
INVERTER:
(1) POWER—ONE # AURORA PVI-3.0-0UTD
(N) 50' TRENCH
• 18" DEEP
LOT 6 • CONDUIT: 1" SCH,
40 PVC WITH WARNING
RIRRC)N F" RFIOW
Building Divisors
CONFIDENTIAL — THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
,OB NUMBER: J[3-8024824 00
PREMISE OWNER:/ / AHk Wheat Ridge
PAOLUCCI, ANDREA
MARKET:
MODULES:
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
OR
5660C W 38TH AVE. LOT 6.
NOR SHALL IT BE DISCLOSED IN WHOLE IN
N. HOMES
12 CANADIAN SOLAR CS6P-250PX
PART OTHERS OUTSIDE THE RECIPIENT'S
ORGANIZATION, EXCEPT IN CONNECTION WITH
WHEAT RIDGE, CO 80212
PROJECT MANAGER:
MOUNTING SYSTEM:
THE SALE AND USE OF THE RESPECTIVE
MATTHEW BRIGGS
SOLARCITY SLEEKMOUNT SYSTEM
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
S(40y--1j 5-3500
PAYMENT TYPE:
LEASE
NVERTER:
(1) POWER—ONE # AURORA PVI-3.0—OUTD
D
PV3
PITCH: 12 ARRAY PITCH: 12
MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180
MATERIAL: Comp Shinqle STORY: Above
1 Fr,Fnin
(E) UTILITY METER & WARNING LABEL
Inv INVERTER W/ INTEGRATED DC DISCO
& WARNING LABELS
OC
DC DISCONNECT & WARNING LABELS
M AC
AC DISCONNECT & WARNING LABELS
0 JUNCTION BOX
O DC COMBINER BOX & WARNING
0 DISTRIBUTION PANEL & WARNING
Lc LOAD CENTER & WARNING LABELS
ODEDICATED PV SYSTEM METER
CONDUIT RUN ON EXTERIOR
CONDUIT RUN ON INTERIOR
GATE/FENCE
- - - INTERIOR EQUIPMENT
SITE PLAN S
Scale: 3/32" = 1' 3 M
01, 10' 21'
N
DESCRIPTION: DESIGN:
NEW TOWN BUILDERS PERRINS ROW CO NIRAJ NISCHAL \\���SolarCity.
3.OKW DC ROOF MOUNT PV SYSTEM
PAGE NAME--
SITE
AMESITE PLAN
3055 Clearview Way San Mateo, CA
SHEET: REV: DATE 94402
T:(650) 638-1028 F:(650) 638-1029
PV 2 8/19/2014 (888) -SOL -CITY (765-2489) www.solarcity.com
Stories
4' MAX. BETWEEN
FOOTINGS STAGGERED
�2' TYP---� L (N) ZEP INTERLOCK
CONFIDENTIAL –THE INFORMAl1ON HEREIN
CONTAINED SHALL NOT BE USED FOR THE
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
(E) 2x4 RAFTERS
24" SPACING
B FRONT VIEW OF MP1
Scale: 1/2"=1'-0"
JOB NUMBER: J13-8024824 OO
MARKET: MODULES:
N. HOMES 12 CANADIAN SOLAR # CS6P-250P
PROJECT MANAGER: MOUNTING SYSTEM:
MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM
PV MODULE
ZEP LEVELING FOOT
HANGER BOLT
ECOFASTEN FLASHING
(E) COMP. SHINGLE
(E) ROOF DECKING
"x4" LAG BOLT
(2—"' EMBED, MIN)
(E) RAFTER
C STANDOFF
Scale: 1-1/2" = 1'
LUWt51 MUUULt ' JUbbLOULN I MUUULLS
GRADE COMPACTED BACKFILL
INSTALLATION ORDER
(1)
LOCATE RAFTER, MARK HOLE
LOCATION, AND DRILL PILOT
HOLE.
(2)
SEAL PILOT HOLE WITH
POLYURETHANE SEALANT.
(3)
INSERT ECOFASTEN FLASHING.
(4)
PLACE FLASHING BLOCK.
(5)
NSTALL LAG BOLT WITH SEALIN
WASHER.
(6)
INSTALL LEVELING FOOT WITH
WASHER AND NUT.
�
w 8" 6 UNDISTURBED SOIL City or
------------
o
he
Rrc/9e
z
guildi,) Div
RED WARNING TAPE �SO�
W/ TRACE WIRE
N
APPROVED BACKFILL
SCHEDULE 40 PVC
CONDUIT
3" 3"
D TRENCH DETAIL
Scale. 3/4 — 1-0
PREMISE OWNER: AHJ: Wheat Ridge DESCRIPTION:
PAOLUCCI, ANDREA NEW TOWN BUILDERS PERRINS ROW C
5660C W 38TH AVE. LOT 6. 3.OKW DC ROOF MOUNT PV SYSTEM
WHEAT RIDGE, CO 80212
TYPE: INVERTER:
LEASE (1) POWER—ONE # AURORA PVI-3.0—OUTD S(4g-�—A34 5— 3 5 0 0
PAGE NAME:
STRUCTURAL VIEWS
NIRAJ NISCHAL \("OlarCly-
3055 Clearview Way San Mateo, CA
SHEET: REV: DATE 94402
T:(650) 638-1028 F:(650) 638-1029
PV 3 8/19/2014 (888) -SOL -CITY (765-2489) www.solarcity.com
:.. l'-2"
SIDE VIEW OF MP T. CHORD: 20 @ 24" O.C.
ASUPPORT: 2X4/3 WEBS, LB
SCALE: 1/4" = 1' MAX SPAN: T-9"
City of
Wheat Fudge
(E) 2X4 TOP CHORD
(E) 2X3 WEBS
(E) 2X4 WEBS
(E) 2X4 BOTTOM
CHORD
HEREIN
CONTAIN D S A THE INFORMATION USED
CONTAINED SHALL NOT BE USED FOR THE
JOB NUMBER:NIRAJ
JB -8024824 0 0
PREMISE OWNER: AHJ: Wheat Ridge DESCRIPTION:
PAOLUCCI ANDREA NEW TOWN BUILDERS PERRINS ROW CO
DESIGN:
NISCHAL \I,\SolarCity
NORBENEFIT SHALL ITYONE EXCEPT BEDISCLOSED IN aWHc� INC.,ORR
5660C W 38TH AVE. LOT 6. 3.OKW DC ROOF MOUNT PV SYSTEM
'��'
MARKT:
N. HOMES
MaouLEs:
12 CANADIAN SOLAR CS6P-250PX
PART TO OTHERS OUTSIDE THE RECIPIENT'S
ORGANIZATION, EXCEPT IN CONNECTION WITH
WHEAT RIDGE CO 80 212
�
PRO ECT MANAGER
MOUNTING SYSTEM:
THE SALE AND USE OF THE RESPECTIVE
MATTHEW BRIGGS
SOLARCITY SLEEKMOUNT SYSTEM
3055 Clearview Way San Mateo, CA
°�02
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
PAGE NAME:
5(49 -A 45-3500 STRUCTURAL VIEWS
SHEET: REV-- DATE
F(650) 638-1029
PV 4 8/19/2014 (888)-SOL-CM(765-2489)www.solarcity.com
PAYMENT TYPE:
LEASE
INVERTER:7:(650)638-1028
(1) POWER -ONE # AURORA PVI-3.0-OUTD
GROUND SPECS
MAIN PANEL SPECS
GENERAL NOTES
INVERTER SPECS
MODULE SPECS LICENSE
BOND (N) #8 GEC TO (E) UFER AT PANEL
(E) 400A MAIN SERVICE PANEL
Inv 1: DC Ungrounded
INV I
-(1)POWER-ONE
S -US -Z -A LABEL:
A
-(12)CANADIAN SOLAR # CS6P-250PX
TYPE EC # 8041
WITH IRREVERSIBLE CRIMP
(E)) 400A LPN -R FUSED MAIN DISCONNECT
Zighee 3000W. 240 -OU
PV Module; 250W, 229.6W PTC, 40mm, Black Frame, MC4, ZEP Ena
led
INV 2
Panel Number:
Meter Number:
Voc: 37.2 Vpmax: 30.1
INV 3
Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER
Is n u Ion
Panel
3 ADJUST MIN. ACTIVATION VOLTAGES! SolarCity
B
MILBANK CUTLER -HAMMER
Inverter 1 PAR
A
Meter Socket Disconnect 3
POWER -ONE
4 1 DC* DON ADJUST MIN. ACTIVATION V TAGS
AURORA PVI-3.0—OUT
1 Strings) Of 6 On MP 1
Dc- �11'
t00A/2P 2OA/2P
C D
zaov
( --------- _EGC-------------
L1
e
L2 DC+
I
I
TO (E) N NEUT
GND GND
EGC Dc+ N t Dc -3
_ _ _
I 2 DC+ DO NOT ADJUST MIN. ACfTdATION V
DISTBUTION D
PANEL
N DC-
�TAGE
DC _ 1 String(s) Of 6 On MP 1
UNIT A I r— — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
— GEC — — — GND _ _ EGC
---
— — — — — — — EGC
---------------------- --–––––––––––––– – – – – – J
OOA/2P
I
I
e
(1)Conduit Kit; 3/4" EMT
N I
TO (E)
DISTIBUTION I I
PANEL I
UNIT 8 I
I
OOA/2P
B
TO E L
DISTIBUTION
City of
PANEL I
UNIT C I
I
hear Ridg
OOA 2P
e
I
s urldin9
N i i
bivison
To (E)
DIST18UT10N
PANEL
UNIT D
I I
I
I
I I
– J I
EGC/GEC
I
O I
I
I
400A FUSED _ _ GECI J
JUMPER
_
B (i )SIEMENS SERIES/\
/� Y gg
A (1)S2x2CS1�MGS,S DC
DISCONNECT #8 I
120/24OV, NEMA63Li125CU
UNFUSED, GROUNDED
(1)MILBANK # U4801–XL-5T9
EC— Meter Socket; 200A, #6-350, Ringless
TO 120/24 -OV BOND (N) #8 EGC/GEC TO (E)
J
– (3)MILBANK N K4977–INT
SINGLE PHASE UFER OR (E) GEC IN
Load–Side Tap Connector, 100A, #12 – 1/0 AWG
UTILITY SERVICE PANEL WITH IRREVERSIBLE
�(1)CUTLER–HAMMER # DG221URB
D
CRIMP PER ART. 250.64(C)
Disconnect; 30A, 240Voc. Non–Fusible, NEMA 3R
– (1)CUTLER–HAMMERB DG030NB
Ground/Neutral It; 30A, General Duty (DG)1)
Wire
AleiaL Clad Cable, 1dG lA/3
w/G 75degC –
POI C 1 )SIEMENS # Q220 PV BACKFEED BREAKER
Breaker, 20A/2P, 2 Spaces
oo (1 )AWG #10, THWN-2, Black – ( 1) AWG #6, Solid Bare Copper GEC
O (1) AWG #10, THWN-2, Red(1)
or
AWG #10, THWN-2, Black
O (1) AWG #10, THAN -2, Red
Voc* = 181.46 VDC Isc = 8.87 ADC (2) AWG 110, PV WIRE, Black Voc* = 181.46 VDC Isc = 8.87 ADC
Vmp = 180.6 VDC Imp= 8.3 ADC O ( I ) AWG #10, Solid Bare Copper EGC Vmp = 180.6 VDC Imp= 8.3 ADC
(1) AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp= 14.5 AAC
J
- (1) AWG #10, THWN-2, Green EGC
– (1) Conduit Kit; 1" PVC, Sch. 40 EGC
(1) AWG 110, THWN-2. Green
EGC
(2) AWG #10, PV WIRE, Black Voc* = 181.46 VDC Isc = 8.87 ADC
2 (1) AWG #10, Solid Bare Copper ECC Vmp = 180.6 VDC Imp= 8.3 ADC
– (1) Wire
"�
Metal Clad Cable; MC 10/3
w/G 75deaC
or
® (1 )AWG #10, THWN-2, Black
V6c* = 181.46 VDC Isc = 8.87 ADC
Vmp = 180.6 VDC Imp= 8.3 ADC
– (1) AWG #10; THWN-2; Red
– (1) AWG #10, THWN-2, Green
EGC
CONFIDENTIAL – THE INFORMATION HEREIN
JOB NUMBER: JB -8024824
��
PREMISE OWNER: AHJ: Wheat Ridge
DESCRIPTION:
DESIGN:
CONTAINED SHALL NOT E USED FOR THE
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
PAOLUCCI, ANDREA
NEW TOWN
BUILDERS PERRINS ROW CO
NIRAJ NISCHAL c ■
;COlar�l+"
�•.,;
MARKET:
MODULES:
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
N. HOMES
12 CANADIAN
SOLAR CS6P-250PX
5660C W 38TH AVE. LOT
6. 3.OKW DC
ROOF MOUNT PV SYSTEM
A J 1. r
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH
WHEAT RIDGE, CO 80212
PROJECT MANAGER:
MOUNTING SYSTEM:
THE SALE AND USE OF THE RESPECTIVE
MATTHEW BRIGGS
SOLARCITY
SLEEKMOUNT SYSTEM
F 3055 Clearview Way San Mateo, cA
SOLARCITY EQUIPMENT, VATHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
S��Q�-A� 45— 3500
PAGE NAME:
THREE LINE DIAGRAM
SHEET: REV: DATE: 94402
T:(65a) 638-1028-2 89) w) 638-1029
PV 5 8/19/2014 (888) -SOL -CITY (765-2489)www.solarcity.com
PAYMENT TYPE:
LEASE
INVERTER:
(1) POWER -ONE # AURORA PVI-3.0-OUTD
1. Conductor Sizing per Art 690.8(8)(1)
a. Conductor must have 30 deg. C ampacity >= 125% of continuous
current per Art 215.2(A)(1).
b. Conductor must have (after corrections for conditions of use) >=
continuous current per Table 310.15(8)(16).
c. Evaluate conductor temperature at terminations per 110.14(0).
Ampacity of wire derated for conditions of termination must be >=
continuous current*1.25. All string terminations ore rated at 90' C.
2. OCP Sizing per Art 690.8(B)(1)
a. Round up to next size per Art 240.4(B)
-------------------------------------------
3. Conductor Sizing per Art 690.8(8)(1)
a. Conductor must have 30 deg. C ampacity >= 125% of continuous
current per Art 215.2(A)(1).
b. Conductor must have (after corrections for conditions of use) > City of °
continuous current per Table 310.15(B)(16).
",Vheat Ridge
c. Evaluate conductor temperature at terminations per Art 110.14(0).
Ampacity of wire derated for conditions of termination must be wilding Divison
continuous current*1.25. All branch terminations are rated at 75*'<�
min.
------------------------------------------
4. OCP Sizing
a. Round up to next size per Art 240.4(B)
------------------------------------------
5. Conductor Sizing per Art 690.8(8)(1)
a. Conductor must have 30 deg. C ampacity >= 125% of continuous
current per Art 215.2(A)(1).
b. Conductor must hove (after corrections for conditions of use) >=
continuous current per Table 310.15(8)(16).
c. Evaluate conductor temperature at terminations per Art 110.14(0).
Ampacity of wire derated for conditions of termination must be >=
continuous current*1.25. All inverter output terminations are rated at
75' C.
-------------------------------------------
6. OCP Sizing
a. Round up to next size per Art 240.4(B)
7 Conductor Sizing per Art 690.8(B)(1)
a. Conductor must have 30 deg. C ampacity >= 125% of continuous
current per Art 215.2(A)(1).
b. Conductor must have (after corrections for conditions of use) >=
continuous current per Table 310.15(B)(16).
c. Evaluate conductor temperature at terminations per Art 110.14(C).
Ampacity of wire derated for conditions of termination must be >=
continuous current*1.25. All inverter output terminations ore rated at
75' C min.
ELECTRICAL CALCULATIONS
Module:
12 Canadian Solar CS6P-250PX-BF
227.6 Inv Power
V\/PTC
MARKET:
Voltage Drop Calculations Version 5_8.0
Vdrop = Imp) 2 * Length) Resistance / Vmp)
1 Imp (A) Max. Length (ft) Wire
String: 1 8.3 15 AWG -10 at Max Ave Hi:89 deg F
Vdrop = 8.3 * 30 * 0.001240hms / 161.90016 0.19
Branch: 1 8.3 50 1 WG 10 at Max Ave Hi:89 deg F
Vdrop = ( 8.3 * 100 * 0.001240hms) / 161.90016 0.64
Total voltage dropin DC conductors = 0.83
Inverter: 1 8.3 95 1 AWG -10 at 240V
Vdrop = ( 8.3 * 190 * 0.0012 Ohms) 240 V 0.7885
Combined: 0 0 1 AWG -10 at 240V
Vdrop = ( O * 0 0.0012 Ohms) / 240 V 0
Total voltage drop in AC conductors = 0.79
Total voltage drop in AC and DC conductors = 1.61
Inverter 1:
1 Power -One PVI -3.0-S AFCI 0.96 3300 2621.95
12 CANADIAN SOLAR CS6P-250PX
Module:
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH
Inverter 2:
PROJECT MANAGER:
Module:
THE SALE AND USE OF THE RESPECTIVE
MATTHEW BRIGGS
Inverter 3:
3055 Clearview way San Mateo, CA
SHEET: REV: 94402
Module:
PAGE NAME:
S40 -Z45-3500 ELECTRICAL CALCULATIONS
DATE: Tt(650 638-1028 E(650)638-1029
PV 6 8/19/2014 (888)-SOL-CrrY(765-2489) www.soiarcity.com
Inverter 4:
NVERTER:
(1) POWER -ONE # AURORA PVI-3.0-OUTD
Total: 12 Modules Total Inv Pwr 3300 12621.95 PTC
Photovoltaic Module Electrical Specifications: Total STC:I 3000
Voc: 37.2 V deg F deg C
Vmp: 30.1 V Record Low Temp: -22 -30
Isc: 8.87 A Max Average Hi Temp: 89 132
Imp: 8.3 A Record Hi Temp: 1 95 135
Tvoc: 0.12648 V/deg C
Tisc: 5.85 mA/deg C
String Type A and 2 Combined Strings Type A
Power -One PVI -3.0-5 AFCI I
6 Canadian Solar C56P- SOPX-BF
Voc= 223.2
Vmp= 180.6
Isc= 8.87
Imp= 8.3
Icont= 11.09 Art 690.8(A)(1)
Voc Correction Method.
Voc Correction Factor:
Min Vdc Input:
Min Vmp at Max Temp:
Max Voc at Min Temp:
Inverter Max Vdc Input:
Max String Size:
1 -way wire length:
Manuf Tvoc
data
Branch Circuit Type A
1 strings per branch 1Inverter
6 modules per series string
Voc= 223.2 V
Vmp= 180.6 V
Isc= 8.87 A
Imp= 8.3 A
Icont= 11.09 A
1 way wire length: 50
strings per branch 2
6 1 modules per series string
Voc= 223.2 V
Vmp= 180.6 V
Isc= 8.87 A
Imp= 8.3 A
Icont= 11.09 A Art 690.8(A)(1)
120
161.9
181.46
600
19
15
1.a Conductor: AWG -10
Icont * 1.25 = (Amps)
30 deg C ampacity =
PV Wire
13.86
40
2.a Conductor 1: AWG 10
Conductor 2: AWG -10
Icont * 1.25 = (Amps)
30 deg C ampacity =
PV Wire
PV Wire
Conductor 1 conductor 2
13.86 13.86
40 40
1.b Icont= (Amps)
Start ampacity
Temperature derate (%=F)
Conduit fill derate (%=#)
Derated ampacity
11.09
40
0.76
E1
30.4
2.b Icont= (Amps)
Start ampacity
Temperature derate (%=F)
Conduit fill derate (°%_#)
Derated ampacity
11.09 11.09
1
40 40
0.76 0.76
0.8 0.8
1.c
Icont * 1.25 = (Amps)
Ampacity
13.86
40
24.321 24.32 1
2.c
Temp table
Icont*1.25= (Amps)
Ampacity
Term 1 Term 2
75degC 75degC
13.86 13.86
35 35
1.d Icont ` 1.25 = (Amps)
OCP Size =
13.86
15
Inverter Type A Output
1 way wire length: 85 ft
Art 690.8(A)(1)
2.d OCP Size =
15 15
Power -One PVI -3.0-S AFCI
Combined Inverter Output
Service Voltage=
Total Inverter Power=
Icont = # of inverters*max inverter
Icont = (Amps)
1 way wire length= 0
current Art 690.8(A)(1)
(cont 1 14.5 7A
3.a Icont * 1.25 = (Amps)
OCP Size =
18.12
Art 690.8(B)(1)
Art 240.6(A)
20
3.b Conductor: 1 AWG_10
Icont * 1.25 = (Amps)
30 deg C ampacity =
THWN-2 at 90 deg C: Table 310.16
18.12
40
4.a Icont*1.25 = (Amps)
OCP size =
18.12
Art 690.8(B)(1)
Art 240.6(A)
20
4.b Conductor: AWG 10
(cont * 1.25 = (Amps)
30 deg C ampacity =
THWN-2 at 90 deg C: Table 310.16
18.12
40
3.c Icont = (Amps)
Start ampacity
Temperature derate (%=F)
Conduit fill derate (%=#)
Derated ampacity
14.5
40
0.91
4.c Icont = (Amps)
Start ampacity
Temperature derate (%=F)
Conduit fill derate (%=#)
Derated ampacity
14.5
1
40
36.4
0.91
3.d Icont * 1.25 = (Amps)
Ampacity
18.12
35
1
36.4
4.d Icont * 1.25 = (Amps)
Ampacity
18.12
E
351
CONFIDENTIAL -THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
,ae NUMBER: JB -8024824 OQ
PREMISE OWNER: AHJ Wheat Ridge DESCRIPTION:
PAOLUCCI, ANDREA NEW TOWN BUILDERS PERRINS ROW CO
DESIGN:
NIRAJ NISCHAL
=�, solarCity.
MARKET:
MODULES:
WH
NOR SHALL IT BE DISCLOSED IN OLE OR IN
N. HOMES
12 CANADIAN SOLAR CS6P-250PX
5660C W 38TH AVE. LOT 6. 3.OKW DC ROOF MOUNT PV SYSTEM
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH
WHEAT RIDGE CO 80212
PROJECT MANAGER:
MOUNTING SYSTEM:
THE SALE AND USE OF THE RESPECTIVE
MATTHEW BRIGGS
SOLARCITY SLEEKMOUNT SYSTEM
3055 Clearview way San Mateo, CA
SHEET: REV: 94402
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
PAGE NAME:
S40 -Z45-3500 ELECTRICAL CALCULATIONS
DATE: Tt(650 638-1028 E(650)638-1029
PV 6 8/19/2014 (888)-SOL-CrrY(765-2489) www.soiarcity.com
PAYMENT TYPE:
LEASE
NVERTER:
(1) POWER -ONE # AURORA PVI-3.0-OUTD
LandsCgpi
:ng Escrow A&Eetnent
This agreement made this 28th day of April, 2015, by and between the City of Wheat
lUk "i azw
5660 W. 38"' Avenue
In the event that landscaping is not installed by June 1, 2015, the City of Wheat Ridge or
its designee shall have the right to enter upon said property to construct and/or install
such improvements or do other such work to accomplish that purpose as may be
necessary, provided that the City of Wheat Ridge shall first give notice in writing to the
property owner of its intent to do so.
If the City of Wheat Ridge exercises its right to perforrn work of any nature, including
labor, materials and use of equipment either by force account or contract, the City shall
have the absolute right to withdraw the escrow funds to complete said improvements.
The only precondition to the City's right to withdraw the funds for this purpose shall be a
letter from the Community Development Director, stating that the improvements have not
been completed or provided and that the compliance date of June 1, 2015, has expired.
MMMMEHMME=
M=
M
• Business Address /Phone
t
Date Title-
Cill of Wheat RidM, Colorado
By:
Title:
Date:—
City of Escrow/Letter of Credit
e-
�COMM 109, Transmittal Sheet
located at 5660 W. 381h Avenue. The escrow is in the amount of Thr!fl
The above amount is to be held in escrow for:
El Street improvements under Public Works:
Z Other: Escrow expires June 1, 2015
The escrow shall be held by the City as reimbursement to offset cost to City
IiIIIIIiiiiiiiRIMI EM: 1 11
Name Date
0
♦�
City of
" jjgic
COMMUNITY DEVELOPMENT
City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033 -8001 P: 303.235.2846 F: 303.235.2857
February 26, 2015
OFFICIAL ADDRESS NOTIFICATION
NOTIFICATION is hereby given that the following address has been assigned to the property /properties as
indicated below:
PROPERTY OWNER(S): NT Perrins LLC
NEW ADDRESS: Wheat Ridge, CO 80212
Lot 1 — 5690 W. 38' Ave., Unit D
Lot 2 — 5690 W. 38 Ave., Unit C
Lot 3 — 5690 W. 38' Ave., Unit B
Lot 4 — 5690 W. 38 Ave., Unit A
Lot 5 — 5660 W. 38" Ave., Unit D
Lot 6 — 5660 W. 38 Ave., Unit C
Lot 7 — 5660 W. 38' Ave., Unit B
Lot 8 — 5660 W. 38' Ave., Unit A
Lot 9 — 5630 W. 38 Ave., Unit D
Lot 10 — 5630 W. 38 Ave., Unit C
Lot 11— 5630 W. 38' Ave., Unit B
Lot 12 — 5630 W. 38 Ave., Unit A
Lot 13 — 3795 Depew St., Unit D
SUBDIVISION: Perrins Row Filing No. 2
Jefferson County Reception Number for Plat: 2013143669
AUTHORIZED BY:
DISTRIBUTION:
Lot 14 - 3795 Depew St., Unit C
Lot 15 — 3795 Depew St., Unit B
Lot 16 — 3795 Depew St., Unit A
Lot 17 — 3791 Depew St., Unit A
Lot 18 — 3785 Depew St., Unit B
Lot 19 — 3785 Depew St., Unit A
Lot 20 — 3781 Depew St., Unit A
Lot 21— 3781 Depew St., Unit B
Lot 22 — 3781 Depew St., Unit C
Lot 23 — 3781 Depew St., Unit D
Lot 24 — 3791 Depew St., Unit D
Lot 25 — 3791 Depew St., Unit C
Lot 26 — 3791 Depew St., Unit B
DATE: 2 — Z 5 - - / 5
1. Jefferson County Assessor, ATTN: Data Control, 100 Jefferson County Parkway, Golden, 80419
2. Jefferson County Mapping, ATTN: Addressing, 100 Jefferson County Parkway, Golden, 80419
3. Jefferson County Elections, ATTN: H. Roth, 3500 Illinois Ave., Laramie Building, Suite 1100, Golden,
CO 80401
4. Email to Jeffco IT Services at smitchel(a�jeffco.us
5. U.S. Post Office, 3700 Tennyson St., Denver, CO 80212
6. Email to erlinda j.martinez@ sps.g and krissv.i.summerfield(a usps.gov
7. Xcel Energy, ATTN: Correspondence, 1123 W. 3rd Ave., Denver, CO 80223
8. Century Link, Capacity Provisioning Specialist, 5325 Zuni St., Room 728, Denver, CO 80221
9. Comcast, Attn: Scott Moore, 6850 S. Tucson Way, Englewood, CO 80112
10. Wheat Ridge Water District
11. Wheat Ridge Sanitation District
12. Wheat Ridge Fire District
13. Wheat Ridge Planning Division
14. Wheat Ridge Building Division
www.d.wheatridge.co.us
15. Wheat Ridge Police Department
16. GIS Specialist
17. Log File
NOTE: Please notify all other parties concerned.
ADDRESS MAP UPDATED BY:
Vicinity May
DATE:
Nk