HomeMy WebLinkAbout5690 W. 38th Avenue, Unit Di CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 03 It<(. -]r-LFC~[ . _PE5. Job Address: . -SA AM Ave t) Permit Number: 2-70-7609 ❑ No one available for inspection: Time /h ( kJ AM/PM Re -Inspection required: Yes (No) When corrections have been made, call for /re-inspe do t 303-234-5933 Date: 2 q Inspector: G r � DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Solar PERMIT - 201707607 PERMIT NO: 201707607 ISSUED: 09/28/2017 JOB ADDRESS: 5690 W 38th AVE UNIT D EXPIRES: 09/28/2018 JOB DESCRIPTION: Permit for remove/reinstall existing system (see 201401543) 3.06 KW Roof mounted PV system. *** CONTACTS *** OWNER (303)707-4422 NT PERRINS SUB (888)765-2489 Jared A Miller 110035 SolarCity Corporation *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2946 / MANSFIELD BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,161.00 FEES Total Valuation 0.00 Use Tax 87.38 Permit Fee 125.05 ** TOTAL ** 212.43 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by m signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications. applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed end that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Off-cial and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permitsh not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or gu on of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat Midge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29"' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: qI)I� P%la�n/PPermit # V\- ri O Plan Review Fee: Building Permit Application C *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 5690 W 38th Ave Unit D, Wheat Ridge, CO 80212 Property Owner (please print): Amber and Wilson Curtis Roberts Phone: Property Owner Email: Cy I S (0-7? Mailing Address: (if different than property address) Address: Same as above City, State, Architect/Engineer: Architect/Engineer E-mail: Contractor: Solar City Contractors City License #: 110035 Contractor E-mail Address: tward@SolarCity.Com Sub Contractors: Phone: Phone: 253-720-4461 Electrical: Plumbing. Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form /Z/Dl`{° I 5�{�j Description -of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION - ❑ RESIDENTIAL ROOFING ❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT BELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT x OTHER (Describe) R&R Solar PV (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) R&R a 3.06 kW roof -mounted grid -tied solar PV system Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ 4161.6 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized Jay the legal owner of any entity included on this application to list that entity on this application. �� CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED PRINT NA_NIE: Tyler Ward ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS SIGNATURE: Fire Department ❑ Received ❑ Not Required TIVE) of (0WVE1 (CONTRACTOR DEPARTMENT USE ONLY Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required TE: 9/22/2017 OCCUPANCY CLASSIFICATION: Building Division Valuation: $ J 1' ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE Wheat icci�e CO/N1NO""r'�u'PA1E"'r 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET AC ALTERNATING TING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN APPROVED BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING PV2 STRUCTURAL VIEWS CONC CONCRETE OF THE HAZARDS PER ART. 690.17. PV4 STRUCTURAL VIEWS Reviewed for Code Com Nana TYPE EC # 8041 C COMBINER BOX 2. EACH UNGROUNDED CONDUCTOR OF THE PV5 THREE LINE DIAGRAM D DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 ELECTRICAL CALCULATIONS DIRECT CURRENT BY PHASE AND SYSTEM PER ART. 210.5. 3. A NATIONALLY -RECOGNIZED TESTING CUTSHEETS ATTACHED EGC EQUIPMENT GROUNDING CONDUCTOR - - - - --- (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN SlensEsaminer DWe EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. 4. CIRCUITS OVER 250V TO GROUND SHALL va"ity of beao� a M,a °,�ovWatO, G SOLAR GUARD METER at�� wwjv�1Mto GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92 B) ( --Ofthe Mo�a+on1101tAe-AA-pcode orofawCoI'ord■+onres.hnmts mO ,mWW*,tov;,Wc,lcowelOwpmv JURISDICTION NOTES GEC GROUNDING ELECTRODE CONDUCTOR 5, DC CONDUCTORS EITHER DO NOT ENTER ; olow owkwv CO*SO/alfm "of ft CRY mrbeVaNd GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 1. THIS SYSTEM IS GRID-INTERTIED VIA A kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE UL -LISTED POWER -CONDITIONING INVERTER. kW KILOWATT UL -LISTED LOCATION PROVIDED BY THE 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND his permit is for the remove/re-install of MIN MINIMUM HARDWARE. INVERTER INPUT CIRCUIT ARE UNGROUNDED. MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED C201401543 Existing equipment reviousl gpreviously permitted on (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 5. ALL WORK TO BE DONE TO 2009 INTERNATIONAL NEC NATIONAL ELECTRIC CODE UL LISTED LAY -IN LUGS LISTED FOR THE BUILDING CODE. ONLY NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE cy NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED 2011 NATIONAL ELECTRIC CODE. 0f kkA- OC ON CENTER RAIL. `c?t R'a9e P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE e4j�ai4 PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. So, PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(B) & 690.47. SS STAINLESS STEEL SSD SEE STRUCTURAL DRAWINGS Srnitli STC STANDARD TESTING CONDITIONS SWH SOLAR WATER HEATER o Waimart TYP TYPICAL F Supercenter ZE IHOP LION UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY Super S Deaver Famous Dave's - V VOLT Stapleton Legendary Pit VmP VOLTAGE AT MAX POWER Bar-B-Que Voc VOLTAGE AT OPEN CIRCUIT W WATT M C 351h Avc 3R NEMA 3R, RAINTIGHT Lather Itirvq Jr Blur; REV BY DATE COMMENTS Prlar"ir Lather King Jr Pot 8.ro x � m CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER:J B-8024997 O O PREMISE OWNER: AHJ: Denver DESCRIP11ON: ROBERTS, AMBER & WILSON, CURTIS NEW TOWN BUILDERS PERRINS ROW CO DESIGN: NIRAJ NISCHAL �:•�, MARKET: N. HOMES MODULES: 12 CANADIAN SOLAR CS6P-255PX BENEFIT OF ANYONE EXCEPT SOLARCITY INC., SHALL IT BE DISCLOSED IN WHOLE OR IN 5690D W. 38TH AVENUE. LOT 1. 3.06KW DC ROOF MOUNT PV SYSTEM �•� solarCity.NOR ►� PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH WHEATRIDGE } CO 80212 PROJECT MANAGER: MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM 3055 Clearview way San Mateo, CA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME: S81§-ZQ46181 COVER SHEET SHEET: I PV REV: PATE: 94402 T:(650) 6311-1028 F:(650) 638-1029 1 8/21/2014 (888)-SOL-CTFY(765-2489)www.solarcity.com PAYMENT TYPE: LEASE INVERTER: (1) POWER -ONE # AURORA PVI-3.0-OUTD J 1' (N) 80' TRENCH • 18" DEEP mmni IIT- 1" cru -T .-- Cit f^• 0 0• • � `\\ N11111I111111111�� Digitally signed by Srihari Raghavan Date: 2014.08.28 23:36:41 -07'00' ON PITCH: 12 ARRAY PITCH: 12 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Como Shinqle STORY: Above I FC;FNrn O (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DISCONNECT & WARNING LABELS AC DISCONNECT &WARNING LABELS O JUNCTION BOX F DC COMBINER BOX & WARNING DISTRIBUTION PANEL & WARNING Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE - - - INTERIOR EQUIPMENT SITE PLAN 01, 10, S 3 M N CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER J B-8024997 OO PREMISE OWNER: AHJ: Denver DESCRIPTION: ROBERTS, AMBER & WILSON, CURTIS NEW TOWN BUILDERS PERRINS ROW COIV DESIGN: 4``l NIRA) NISCHAL MARKET: N. HOMES MODULES: 12 CANADIAN SOLAR CS6P-255PX BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 5690D W. 38TH AVENUE. LOT 1. 3.06KW DC ROOF MOUNT PV SYSTEM � ,;So�arCity. PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH WH E A TR I D G E CO 80212 3055 Clearview way San Mateo, CA PROJECT MANAGER MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM PAGE NAME: 94402 SHEET: REV: DATE PAYMENT TYPE: LEASE INVERTER: (1) POWER -ONE #AURORA PVI-3.0-OUTD SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 1 6181 S U��, SITE PLAN T:(650)638-1028 F:(650) 638-1029 PV 2 8/21/2014, (888) -SOL -CITY (765-2489) www.solarcity.com Stories I' MAX. BETWEEN STANDOFF FOOTINGS STAGGERED PV MODULE Scale: 1-1/2" = 1' INSTALLATION ORDER ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE - - - HANGER BOLT (6) (1) LOCATION, AND DRILL PILOT (4) HOLE. ECOFASTEN FLASHING(2) SEAL PILOT HOLE WITH �2' TYP---� (N) ZEP INTERLOCK (E) COMP. SHINGLE * - - - - - *`17 - - - - - - - POLYURETHANE SEALANT. (E) 2x4 RAFTERS (3) (3) INSERT ECOFASTEN FLASHING. @ 24" SPACING (E) ROOF DECKING FRONT VIEW OF MP1r B ;�"x4" LAG BOLT (2) � (4) PLACE FLASHING BLOCK. Scale: 1/2"=1'-0" (2-"" EMBED, MIN) (5) (5) NSTALL LAG BOLT WITH SEALING (E) RAFTER LOWEST MODULE SUBSEQUENT MODULES WASHER. (6) INSTALL LEVELING FOOT WITH STAMPED AND SIGNED WASHER AND NUT. FOR STRUCTURAL ONLY Digitally signed by Srihari Raghavan Date: 2014.08.28 23:36:53 -07'00' CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WTHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J13-8024997 00 MARKET: MODULES: N. HOMES 12 CANADIAN SOLAR # CS6P-255PX PROJECT MANAGER: MOUNTING SYSTEM: MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM PAYMENT TYPE: INVERTER: LEASE (1) POWER -ONE # AURORA PVI -3.0 -OU (ID Anr (: §)— TRENCH DETAIL Scale. 3/4 - 1-0 UNDISTURBED SOIL RED WARNING TAPE W/ TRACE WIRE APPROVED BACKFILL SCHEDULE 40 PVC CONDUIT PREMISE OWNER: AHJ: Denver DESCRIPTION: DESIGN: ROBERTS, AMBER & WILSON, CURTIS NEW TOWN BUILDERS PERRINS ROW CO NIRAJ NISCHAL 5690D W. 38TH AVENUE. LOT 1. 3.06KW DC ROOF MOUNT PV SYSTEM WHEATRIDGE, CO 80212 PAGE NAME: STRUCTURAL VIEWS SHEET: REV: PV 3 ,SolarCity. 3055 Clearview Way San Mateo, CA DATE: 94-102 T:(650) 638-1028 F:(650) 638-1029 8/21/201 4 (888) -SOL -CITY (765-2489) www.solarcity.com STAMPED AND SIGNED Digitally signed by Srihari Raghavan Date: 2014.08.28 23:37:02 -07'00' C;ly 01 SIDE VIEW OF MP T. CHORD: 2x6 @ 24" O.C. ASUPPORT: 2X4 WEBS, LBW SCALE: 1/4" = 1' MAX SPAN: 7'-0" (E) 2X6 TOP CHORD (E) 2X4 WEBS (E) 2X4 BOTTOM CHORD CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE Joe NUMBER: JB -8024997 00 PREMISE OWNER: AHJ: Denver DESCRIPTION: ROBERTS, AMBER & WILSON, CURTIS NEW TOWN BUILDERS PERRINS ROW COIv DESIGN: NIRAJ NISCHALBEN MARKET: N. HOMES MODULES: 12 CANADIAN SOLAR CS6P-255PX ANYONE EXCEPT NOREFSH LL IT BE DISCLOSED INWHOLEORCIN 5690D W. 38TH AVENUE. LOT 1. 3.06KW DC ROOF MOUNT PV SYSTEM , ;SolarCity. " PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH WH E A TR I D G E CO 80212 � PRO,ECT MANAGER: MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM PAGE NAME: 3055 Clearview Way San Mateo, CA SHEET: REV: DATE 94402 PAYMENT TYPE: LEASE INVERTER: (1) POWER -ONE #AURORA PVI-3.0-OUTD SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. s812��.QQ,6181 STRUCTURAL VIEWS T:(650)638-1028 F:(650)638-1029 PV 4 8/21/2014 (888) -SOL -CRY (765-2489)www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) LIFER AT PANEL (E) 400A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1 - (1)AABBF In \A -3.O Z O TD S-US-Z277Y/240V/208V, 96z �6 f - (12) CANADIAN SOLAR CS6P-255PX TYPE EC # 8041 WITH IRREVERSIBLE CRIMP (E)) 400A LPN -R FUSED MAIN DISCONNECT PV Module; 255 234.3W PTC, Block Frame, MC4, ZEP Enabled INV 2 Panel Number: Meter Number: Voc: 37.4 Vpmax: 30.2 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER Is n u wn Panel 3 ADJUST MIN. ACTIVATION VOLTAGES! SolarCity B MILBANK CUTLER -HAMMER Inverter 1 PAR :A:]- r� Meter Socket Disconnect Meter 4 1 DO NOT ADJUST MIN. ACTIVATION V TAGE 3 POWER -ONE DC, �\ AURORA PVI -3.0 -OU -S -US -Z -A DC- 1 String(s) Of 6 On MP 1 10OA/2P 20�P C D _ _ EGC %-�� e � I L2 DC+ I TO (E) N NEUT _ — -- — GND -- -- -- GND ------------- EGC DC+ DC -3 I z DC, DO NOT ADJUST MIN. AC 1VATION V TAGE -- --- DISTIBU11ON PANEL I GND IStnn s Of 6 O MP N DC- DC- String(s) UNIT ' --- ------- --—-----------—---- - - - - - - - — - — — GND EGC — — — — — — — — — — — — — — — — — — — — — — — — — — — —� — — — — — — E - - - - - - - - - - — -GEC - - - - - - - - - - - - - - - - - - - - - J OOA/2P I a N ' TO (E) I I DISTIBUTION I PANEL UNIT 6 I OOA/2P LI TO E DISTIBUTION ' PANEL I UNIT C I ' I OOA/2P I I II A a I II City or ro (E) N CONDUIT IS TO BE MOUNTED MORE THAN 1/2" ABOVE ROOF w�l@ 8t DISTIOUTION i SURFACE TO PREVENT FURTHER AMPACITY DERATING UNDER Ridge PANEL I NEC 310.15(B)(2)(C). g�iidi ng vson II it ecc;cec I o ' I I � 400A FUSED _ _ cecl J DISCONNECT #8 JUMPER (1 )SIEMENS SERIES - A NEM 3R: WO816ML1125CU Load Center; 125A, 120/24OV, NEMA 3 /f► A (1 )SolarCity p 4 STRING JUNCTION BOX D� A 2x2 SIRMGS, UNFUSED, GROUNDED #69 �(1)MILBer # Ut; 200 Meter Socket; #6-350, Ringless TO 120/240V BONG N EGC GEC TO E / () #$ / () , -(3)MILBANK g K4977 -INT 7 -IN SINGLE PHASE LIFER OR (E) GEC IN Load -Side Tap Connector; 100A, 112 - 1/0 AWG UTILITY SERVICE PANEL WITH IRREVERSIBLE D (I)CUTLER-HAMMER # DG221URB CRIMP PER ART. 250.64(C) Disconnect; 30A, 240Vac, Non -Fusible, NEMA 3R - (1)CUTLER-HAMMER # DGO3ONB Ground/Neutral It; 30A, General Duty (DG) - ( 1) Wire - - - -- - - - -- - POI (1) SIEMENS Q220 PV BACKFEED BREAKER Breaker, 20A/2P, 2 SpacesO -- - --- a----- - - �1etaL-Ckld�ableMC 10/3 w/G ISdegG (1) AWG #10, THWN-2, Black - ( 1) AWG /6, Solid Bare Copper GEC or c°°�n (1) AWG #10, THWN 2, Red (1 ) AWG #10, THWN-2, Block Voc* = 266.36 VDC Isc = 9 ADC (2) AWG 110, PV WIRE, Block Voc' = 266.36 VDC Isc = 9 ADC O (1 ) AWG Solid Bare Copper EGC Vmp = 181.2 VDC Imp= 8,43 ADC (1 )AWG #10, THWN-2, White NEUTRAL Vmp = 240 VAC Imp=14.5 AAC O (1 ) AWG #10, THIAN-2, Red Vmp = 181-2 VDC Imp= 8.43 ADC 110, - (1) AWG #10, THWN-2, Green EGC - (1 ) Conduit Kit; 1" PVC, Sch. 40 EGC (1) AWG #10, THWN-2, Green EGC T (2) AWG 110, PV WIRE, Black Voc* = 266.36 VDC Isc = 9 ADC O Ic : (1 ) AWG #10, Solid Bare Copper EGC Vmp = 181.2 VDC Imp= 8.43 ADC - ( 1) Wire �� Metal Clad Cable; MC 10/3 w/G 75de C or 7�c* = 266.36VDC Isc = 9 ADC (1 )AWG #10, THWN-2, Black Vmp = 181.2 VDC Imp= 8.43 ADC - (i ) AWG /10, THWN--2. Red - (1) AWG #10, THWN-2, Green EGC CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER:J B-8024997 00 PREMISE OWNER: AHJ: Denver DESCRIPTION: ROBERTS AMBER & WILSON CURTIS NEW TOWN BUILDERS PERRINS ROW CO DESIGN: NIRAJ NISCHAL MARKET: N. HOMES MODULES: 12 CANADIAN SOLAR CS6P-255PX BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 5690D W. 38TH AVENUE. LOT 1. 3.06KW DC ROOF MOUNT PV SYSTEM •1O So�a�City. ►�, PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH WHEATRIDGE, CO 80212 PROJECT MANAGER: MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM 3055 Clearview way San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. s81 ,6181 PAGE NAME: THREE LINE DIAGRAM SHEET: REV: PATE: T:(650) 638-1028 F:(650) 638-1029 PV 5 8/21/2014 (888) -SOL -Cr -FY (765-2489) www.solarcity.com PAYMENT TYPE: LEASE INVERTER: (1) POWER -ONE # AURORA PVI-3.0-OUTD 1. Conductor Sizing per Art 690.8(8)(1) a. Conductor must have 30 deg. C ampocity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(8)(16). c. Evaluate conductor temperature at terminations per 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All string terminations are rated at 90' C. ------------------------------------------ 2. OCP Sizing per Art 690.8(6)(1) a. Round up to next size per Art 240.4(B) ------------------------------------------- 3. Conductor Sizing per Art 690.8(8)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All branch terminations are rated at 75' C min. ------------------------------------------ 4. OCP Sizing a. Round up to next size per Art 240.4(B) ------------------------------------------ 5. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(6)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All inverter output terminations are rated at 75' C. ------------------------------------------- 6. OCP Sizing a. Round up to next size per Art 240.4(B) 7, Conductor Sizing per Art 690.8(B)(1) a. Conductor must hove 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All inverter output terminations are rated at 75' C min. City of Wheat Ridge CONFIDENTIAL - THE INFORMATION HEREIN JDB NUMBER: JB -8024997 00 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET MODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN N. HOMES 12 CANADIAN SOLAR # CS6P-255PX PART TO OTHERS OUTSIDE THE RECIPIENT'S PROJECT MANAGER: MOUNTING SYSTEM: ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE MATTHEW BRIGGS SOLARCITY SLEEKMOUNT SYSTEM SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER: PERMISSION of SOLARCITY INC. LEASE (1) POWER -ONE # AURORA PVI -3.0 -OU ELECTRICAL CALCULATIONS Module: 12 Canadian Solar CS6P-255PX 234.3 Inv Power WPTC Voltage Drop Calculations Version 5_8.0 Vdrop = Imp) * 2 * Length) Resistance / Vmp) Imp (A) Max. Length (ft) Wire String: 8.43 15 AWG_10 I at Max Ave Hi:89 deg F Vdrop = 8.43 * 30 * 0.00124C)hms / 162.50016 0.19 Branch: 8.43 50 1 AWG_10 at Max Ave Hi:89 deg F Vdrop = ( 8.43 * 100 * 0.00124phms) / 162.50016 0.64 Total voltage dropin DC conductors = 0.84 Inverter: 8.43 95 1 AWG_10 at 240V Vdrop = ( 8.43 * 190 * 0.0012 Ohms)/ 240 V 0.80085 Combined:1 0 0 1 AWG_10 at 240V Vdrop = (0 * 0 0.0012 Ohms) / 240 V 0 Total voltage drop in AC conductors = 0.8 Total voltage drop in AC and DC conductors = 1.64 Inverter 1: 1 ABB PVI -3.0-S AFCI 0.96 3300 2699.14 Module: Inverter 2: Module: Inverter 3: Module: i Inverter 4: Total: 12 Modules Total Inv Pwr: 3300 12699.14 PTC Photovoltaic Module Electrical Specifications: Total STC:I 3060 Voc: 37.4 V deg F deg C Vmp: 30.2 V Record Low Temp: -22 -30 Isc: 9 A Max Average Hi Temp: 89 32 Imp: 8.43 A Record Hi Temp: 1 95 135 Tvoc: -0.12716 V/deg C Tisc: 5.85 mA/deg C String Type A and 2 Combined Strings Type A ABB PVI -3.0-5 AFCI 6 Canadian Solar CS6P- 55PX Voc= 224.4 Vmp= 181.2 Isc= 9 Imp= 8.43 Icont= 11.25 Art 690.8(A)(1) Voc Correction Method: Voc Correction Factor: Min Vdc Input: Min Vmp at Max Temp: Max Voc at Min Temp: Inverter Max Vdc Input: Max String Size: 1 -way wire length: Manuf Tvoc data Branch Circuit Type A 1 strings per branch 1Inverter 61m dules per series string Voc= 224.4 V Vmp= 181.2 V Isc=9 A Imp= 8.43 A Icont= 11.25 A 1 way wire length: 50 strings per branch 2 I 61m dules per series string Voc= 224.4 V Vmp= 181.2 V Isc= 9 A Imp= 8.43 A (cont= 11.25 A Art 690,8(A)(1) 120 162.5 266.36 600 13 15 1.a Conductor: AWG_10 Icont * 1.25 = (Amps) 30 deg C ampacity = PV Wire 14.06 401 F 2.a Conductor 1: AWG 10 Conductor 2: i AWG_10 Icont * 1.25 = (Amps) 30 deg C ampacity = PV Wire PV Wire Conductor 1 Conductor 2 14.06 14.06 40 40 1.b Icont= (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%=#)1 Derated ampacity 11.25 40 2.b Icont= (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity 11.25 11.25 0.76 40 40 0.76 0.76 30.4 0.8 0.8 1.c Icont * 1.25 = (Amps) Ampacity 14.06 40 24.32 24.32 2.c Temp table Icont*1.25= (Amps) Ampacity Term 1 Term 2 175degC I 75degC 1 14.061 14.06 35 35 1.d Icont * 1.25 = (Amps) OCP Size = 14.06 15 Inverter Type A Output 1 way wire length: 85 ft Art 690.8(A)(1) 2.d OCP Size = 15 15 ABB PVI -3.0-S AFCI Combined Inverter Output Service Voltage= Total Inverter Power= 1 way wire length= 0 Icont = # of inverters*max inverter current Art 690.8(A)(1) Icont = (Amps) Icont I 14,57A 3.a Icont * 1.25 = (Amps) OCP Size = 18.12 Art 690.8(B)(1) Art 240.6(A) 20 3.b Conductor: 1 AWG_10 Icont * 1.25 = (Amps) 30 deg C ampacity = THWN-2 at 18.12 40 90 deg C: Table 310.16 4.a Icont*1.25 = (Amps) OCP size 18.12 Art 690.8(B)(1) Art 240.6(A) 1 20 4.1b Conductor: AWG_10 Icont * 1.25 = (Amps) 30 deg C ampacity = THWN-2 at 90 deg C: Table 310.16 18.12 40 3.c Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%=#) Derated ampacity 14.5 40 0.91 1 4.c Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity 14.5 40 36.4 0.91 3.d Icont * 1.25 = (Amps) Ampacity 18.12 35 1 36.4 4.d Icont * 1.25 = (Amps) Ampacity 18.12 35 PREMISE OWNER: AHJ: Denver DESCRIPTION: DESIGN: ROBERTS, AMBER & WILSON, CURTIS NEW TOWN BUILDERS PERRINS ROW Coy NIRAJ NISCHAL 5690D W. 38TH AVENUE. LOT 1. 3.06KW DC ROOF MOUNT PV SYSTEM WHEATRIDGE, CO 80212 PAGE NAME: ELECTRICAL CALCULATIONS SHEET: REV: PV 6 � solarCity. 1 3055 Clearview Way San Mateo, CA DATE: -402 T:(650) 638-1028 F:(650) 638-1029 8/21 /2014 (888) -SOL -CITY (765-2489) www,solarcity.com i CITY OF WHEAT RIDGE �� Building Inspection Division ►/ (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax Inspection Type: Job Address: INSPECTION NOTICE Permit Number: ❑ No one available for inspection: Time AM�M Re- Inspection required: Yes No * When corrections have been made, call for re- inspection at 303 - 234 -5933 Date Inspector: DO NOT REMOVE THIS NOTICE ♦� City of " jjgic COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033 -8001 P: 303.235.2846 F: 303.235.2857 February 26, 2015 OFFICIAL ADDRESS NOTIFICATION NOTIFICATION is hereby given that the following address has been assigned to the property /properties as indicated below: PROPERTY OWNER(S): NT Perrins LLC NEW ADDRESS: Wheat Ridge, CO 80212 Lot 1 — 5690 W. 38' Ave., Unit D Lot 2 — 5690 W. 38 Ave., Unit C Lot 3 — 5690 W. 38' Ave., Unit B Lot 4 — 5690 W. 38 Ave., Unit A Lot 5 — 5660 W. 38" Ave., Unit D Lot 6 — 5660 W. 38 Ave., Unit C Lot 7 — 5660 W. 38' Ave., Unit B Lot 8 — 5660 W. 38' Ave., Unit A Lot 9 — 5630 W. 38 Ave., Unit D Lot 10 — 5630 W. 38 Ave., Unit C Lot 11— 5630 W. 38' Ave., Unit B Lot 12 — 5630 W. 38 Ave., Unit A Lot 13 — 3795 Depew St., Unit D SUBDIVISION: Perrins Row Filing No. 2 Jefferson County Reception Number for Plat: 2013143669 AUTHORIZED BY: DISTRIBUTION: Lot 14 - 3795 Depew St., Unit C Lot 15 — 3795 Depew St., Unit B Lot 16 — 3795 Depew St., Unit A Lot 17 — 3791 Depew St., Unit A Lot 18 — 3785 Depew St., Unit B Lot 19 — 3785 Depew St., Unit A Lot 20 — 3781 Depew St., Unit A Lot 21— 3781 Depew St., Unit B Lot 22 — 3781 Depew St., Unit C Lot 23 — 3781 Depew St., Unit D Lot 24 — 3791 Depew St., Unit D Lot 25 — 3791 Depew St., Unit C Lot 26 — 3791 Depew St., Unit B DATE: 2 — Z 5 - - / 5 1. Jefferson County Assessor, ATTN: Data Control, 100 Jefferson County Parkway, Golden, 80419 2. Jefferson County Mapping, ATTN: Addressing, 100 Jefferson County Parkway, Golden, 80419 3. Jefferson County Elections, ATTN: H. Roth, 3500 Illinois Ave., Laramie Building, Suite 1100, Golden, CO 80401 4. Email to Jeffco IT Services at smitchel(a�jeffco.us 5. U.S. Post Office, 3700 Tennyson St., Denver, CO 80212 6. Email to erlinda j.martinez@ sps.g and krissv.i.summerfield(a usps.gov 7. Xcel Energy, ATTN: Correspondence, 1123 W. 3rd Ave., Denver, CO 80223 8. Century Link, Capacity Provisioning Specialist, 5325 Zuni St., Room 728, Denver, CO 80221 9. Comcast, Attn: Scott Moore, 6850 S. Tucson Way, Englewood, CO 80112 10. Wheat Ridge Water District 11. Wheat Ridge Sanitation District 12. Wheat Ridge Fire District 13. Wheat Ridge Planning Division 14. Wheat Ridge Building Division www.d.wheatridge.co.us 15. Wheat Ridge Police Department 16. GIS Specialist 17. Log File NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: Vicinity May DATE: Nk