HomeMy WebLinkAbout2880 Newland StreetPERMIT: ADDRESS: ;'.f ` JOB CODE
INSPECTION RECORD
Inspection online form: http://www.ci.wheatridge.co.us/inspection
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site
Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business
Foundation Inspections
Date
Inspector
Initials
Comments
102 Caissons / Piers
103 Footing / P.E. Letter
104 Foundation Setback Cert.
105 Stem Walls
106 Foundation wall Insulation
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground / Slab Inspections
Date
Inspector
Initials
Comments
201 Electrical / Cable/ Conduit
202 Sewer Underground Int.
203 Sewer Underground Ext.
204 Plumbing Underground Int.
205 Plumbing Underground Ext.
206 Water Underground
Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections
Rough Inspection
Date
Inspector
Initials
Comments
301 Rough Framing
302 Wall Sheathing
303 Roof Sheathing
304 Sheer Inspection
305 Insulation
306 Mid -Roof
307 Metal / Lath / Stucco
308 Rough Electrical Residential
309 Rough Electrical Commercial
310 Electrical Meter Residential
311 Electrical Meter Commercial
312 Temp. Const. Meter
313 Rough Plumbing Residential
314 Rough Plumbing Commercial
315 Shower Pan
SEE OVER FOR ADDITIONAL INSPECTIONS
Rough Inspection (continued)
Date
Inspector
Initials
Comments
316 Rough Mechanical Residential
317 Rough Mechanical Commercial
318 Boiler / Furnace
E
319 Hot water tank
`320 Drywall screw and Nail
321 Moisture board / shower walls
322 Rough Grading
323 Miscellaneous
Final Inspections
Date
Inspector
Initials
Comments
402 Gas Meter Release
403 Final Electrical Residential
404 Final Electrical Commercial
405 Final Mechanical Residential
406 Final Mechanical Commercial
407 Final Plumbing Residential
408 Final Plumbing Commercial
409 Final Roof
410 Final Window/Door
411 Landscape/Park/Planning
Inspections from these entities shall be requested
one week in advance.
For landscaping and parking inspections please
call 303-235-2846
For ROW and drainage inspections please call
303-235-2861
For fire inspections please contact the Fire
Protection District for your project.
412 Row/Drainage/Public Works
413 Flood plain Inspection
414 Fire Insp. / Fire Protection
415 Public Works Final
416 Storm Water Mgmt.
417 Zoning Final Inspection
418 Building Final Inspection
Note: All items must be completed and approved by Planning, Public Works, Fire and Building
before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not
constitute authorization of occupancy.
For Low Voltage permits please be sure that rough inspections are completed by the Fire District and
Electrical low voltage by the Building Division.
The City of Wheat Ridge
Third Party Form Check List
Property Address 2880 Newland Street
Permit Number 201707997
Permit Issued Date 10/04/2017
Owner Information
Property Owner Information Thad Dahl
Property Owner Address 2880 Newland Street
Inspector Information
Inspection Company Certified Building Consultants
Inspector Name Kraig Stanforth
Inspector Contact info. 720-940-1180 KStanforthCBCCa).gmail.com
Inspector Statement of Acknowledgement
*1 hereby acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under
6/12 must be inspected by the City of Wheat Ridge Building Department.
*1 hereby acknowledge the roofing sys em for the referenced building has been
inspected and found to be in compli ce with the minimum requirements of the 2012
IRC and 2012 IBC as well as he of Whea Ridge Policies and Procedur and
manufac eQommend�io d specif tions. � 7
Inspector:
Date: ////l '))
*1 hereby acknowledge that I bfn the owner of the building referenced above
my consent for the listed third -party inspection company to perform my roof 1
in lieu of the City of Wheat RidgeeStailcH ig aiyi on itlspection. }
Property Owner/Agent: .�; �.�� Date: (/
This original document, as well as the roofing checklist, must be
Building Official within seven days of the final inspection.
Drop off in person
Permit Counter 2nd Floor
7500 W. 29th Ave
Wheat Ridge, CO 80033
Submit via Email
Kcook rci.wheatridge.co.us
the Chief
CBC Wheat Ridge Roof Inspection Packet Page 1 of 5
❑ N/A
❑ N/A
❑ N/A
N/A
N/A
X X.,N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
N/A
A, N/A
N/A
N/A
N/A
The City of Wheat Ridge
Inspection Check List Notes
Mid -Roof
Roof Inspection
Pass
❑
Fail
Structural roof components
Pass
❑
Fail
Verify that no more than 2 layers of shingles exist
/A�' Pass
❑
Fail
Flashing for roof and walls
A Pass
❑
Fail
If new sheathing is installed, verify that it is listed in the permit
description (Valuation must be adjusted)
" Pass
❑
Fail
Verify sheathing nail pattern (see Policy and Procedures)
QCT Pass
❑
Fail
Crickets and saddles where needed
Pass
❑
Fail
Verify vent must have boot same gauge as pipe
Pass
❑
Fail
Verify vent caps
ass
iiFail
Verify no flashings are damaged or rusted
ass
tppass
11Fail
Step flashing shall be min. of 4x4 piece per shingle
❑
Fail
Verify scuppers allow for proper drainage
A Pass
❑
Fail
Ice and water shield 2' in heated wall spaces
Pass
❑
Fail
Underlayments must follow 2012 IRC/2012 IBC
�( Pass
❑
Fail
Verify roof slope for proper damage
Pass
❑
Fail
Dripedge shall have min. of 2" overlap
Pass
❑
Fail
Dripedge should extend down min. 2" past roof deck
Pass
❑
Fail
Dripedge shall be mechanically fastened 12" OC
❑ Pass
❑
Fail
90 LB roof roofing shall not be applied to roof slopes less than
2:12 slope. Exception, detached garages, patios, carports, open
on three sides with min. slope of 1:12
❑ Pass
❑
Fail
Above roof insulation R-25
❑ Pass
❑
Fail
Below roof residential R-38
❑ Pass
❑
Fail
Below roof commercial R-32
❑ Pass
❑
Fail
Modified Bitumen, EPDM, TPO min. slope 1/4:12 slope must be
installed in accordance with the manufacturer's specifications.
Must have manufacturer's letter of warranty with the address
on the letter for final inspection
Metal Roof Shingles
Requirements
N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less than 3:12
N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof
N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min. of 8" from the
centerline with a min. of 3/4 " high splash diverter rib built-in at
the flow line with the sections overlapping a min. of 4"
Tile Roof Requirements
N/A ❑ Pass ❑ Fail Clay and concrete the shall have a min. 2-1/2:12 slope
N/A ❑ Pass ❑ Fail Slopes 4:12 and under require double underlayment
CBC Wheat Ridge Roof Inspection Packet Page 2 of 5
Company Name:
Inspector Signature:
Date of Inspection:
The City of Wheat Ridge
Inspection Check List Notes
Mid -Roof
Notes
CBC Wheat Ridge Roof Inspection Packet Page 3 of 5
The City of Wheat Ridge
Inspection Check List Notes
Final Roof
Roof Inspection
❑
N/A
Pass
❑
Fail
Structural roof components
❑
N/A
Pass
❑
Fail
Verify that no more than 2 layers of shingles exist
❑
N/A
Pass
❑
Fail
Flashing for roof and wails
❑
N/A
Pass
❑
Fail
Structural roof components
❑
N/A
Pass
❑
Fail
If new sheathing is installed verify that it is listed in the
permit description (Valuation must be adjusted)
❑
N/A
Pass
❑
Fail
Verify sheathing nail pattern (See Policy and Procedures)
/N/A
❑ Pass
❑
Fail
Crickets and saddles where needed
❑
N/A
Pass
❑
Fail
Verify B vent must have boot same gauge as pipe
❑
N/A
y Pass
❑
Fail
Verify vent caps
❑
N/A
'J Pass
❑
Fail
Verify no flashings are damaged or rusted
❑
N/A
Pass
❑
Fail
Step flashing shall be min. of 4x4 piece per shingle
❑
N/A
Pass
❑
Fail
Verify scuppers allow for proper drainage
❑
N/A
Pass
❑
Fail
Ice and water shield 2' in heated wall spaces
❑
N/A
Pass
❑
Fail
Underlayments must follow 2012 IRC/2012 IBC
❑
N/A
Pass
❑
Fail
Verify roof slope for proper drainage
❑
N/A
Pass
❑
Fail
Dripedge shall have min. 2" of overlap
❑
N/A
Pass
❑
Fail
Dripedge should extend down min. 2" past roof deck
❑
N/A
Pass
❑
Fail
Dripedge shall be mechanically fastened 12" OC
N/A
❑ Pass
❑
Fail
90 LB roll roofing shall not be applied to roof slopes less than
2:12 slope: Exception, detached garages, patios, carports, open
on three sides with min. slope of 1:12
N/A
❑ Pass
❑
Fail
Modified Bitumen, EPDM, TPO min. slope 1/4:12 slope must be
installed in accordance with the manufacturer's letter of
warranty with the address on the letter for final inspection
Metal Roof Shingles
Requirements
N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less than 3:12
N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof
/91 � N/A ❑ Pass [i Fail Metal valley flashing shall extend a min. of 8" from the
centerline with a min. of 3/4 " high splash diverter rib built-in at
the flow line with the sections overlapping a min. of 4"
Tile Roof Requirements
N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope
tA N/A ❑ Pass ❑ Fail Slopes 4:12 and under require double underlayment
CBC Wheat Ridge Roof Inspection Packet Page 4 of 5
Company Name:
Inspector Signature:
Date of Inspection:
The City of Wheat Ridge
Inspection Check List Notes
Final Roof
Notes
CBC Wheat Ridge Roof Inspection Packet Page 5 of 5
Memorandum
TO:
FROM:
SUBJECT:
DATE:
City of Wheat Ridge
Community Development Department
Accounting Department
Kim Cook, Building Division
Refund for Permit
September 21, 2017
Reason: Homeowner cancelled the contract therefore this permit is closed as
void; Permit No. 201702875 at 2880 Newland Street needs to be cancelled.
Please refund: Contractors License$ (acct 01-510-00-513)
80% permit fee: $ 188.80 (acct 01-510-00-516)
0% plan review $ (acct 01-550-05-551)
100% use tax: $ 237.47 (acct 01-500-02-505)
Total: $ 426.27
TO:
Colorado Exteriors LLC
747 Sheridan Boulevard #1A
Lakewood CO 80214
Thank You!
gzol Cac%
Permit Technician
City of
Wheatle
COMMUNITY DEVELOPMENT
&Y .4-ts r,n d
^lam 1xi i) rx-- d 0 F. �
City of Wheat Ridge Municipal Building 7500 W. 291h Ave. Wheat Ridge, CO j
800033-8001 P: 303.235.2855 F: 303.237.8929
015q0jL__'
Refund Application 6 JI/) 7
Complete this application in its entirety, attach all copies of permits, permit cards (if issued) andreceipts t
were received at the time of permit issuance. Requests for more than 80 percent of the amount paid will not e
approved without prior approval from the Building Official. The refund application must be received by the
Wheat Ridge Building Division no later than 180 days after permit issuance. Applications received after 180
days of permit issuance will not be approved. You can mail or hand -deliver all required documents to: City of
Wheat Ridge, Attn: Building Division, 7500 W. 29th Ave., Wheat Ridge, CO 80033.
r
Company Name/Name (to whom check should be made out to):
Address:—j
City: State: Zip:
Phone: l�L� Fax:, -,-3/
_�`_3jS3 Email:
Printed Name:
Signature: � Date:
/:�_ 4U)
For office use only
A
f
This request has been: / roved Denied Refund }Amount: $
gs
Approved by: W' Date:
www.ci.wheatridge.co. us
Dane Lovett Zv I ZO 7 qqZ
From: no-reply@ci.wheatridge.co.us
Sent: Monday, October 2, 2017 9:27 AM
To: CommDev Permits
Subject: Online Form Submittal: Residential Roofing Permit Application
Follow Up Flag: Follow up
Flag Status: Completed
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address 2880 Newland Street
Property Owner Name Kelli Dahl
Property Owner Phone 303-905-7082
Number (enter WITH
dashes, eg 303-123-4567)
9
Property Owner Email Field not completed.
Address
Do you have a signed Yes
contract to reroof this
property?
Applications cannot be
submitted without an
executed contract
attached below.
Attach Copy of Executed Dahl Client Agreement.pdf
Contract
:�Z�7���7_«Ci7�l�l�i : ►7 7 �I_�r[�7r1
Contractor Business
Endeavor Exteriors
Name
Contractor's License
160159
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone
720-536-8870
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Address
7808 Cherry Creek South Drive #401
(Primary address of your
business)
Contractor Email Address
production@endeavorexteriors.com
Retype Contractor Email
production@endeavorexteriors.com
Address
]a:t"M, 27NP►[e73f106
TOTAL SQUARES of 37
the entire scope of work:
Project Value (contract 21827.81
value or cost of ALL
materials and labor)
Are you re -decking the No
roof?
Is the permit for a flat Pitched roof (2:12 pitch or greater)
roof, pitched roof, or
10
both? (check all that
apply)
What is the specific pitch 8/12
of the PITCHED roof?
How many squares are 37
part of the PITCHED
roof?
Describe the roofing Asphalt shingles
materials for the
PITCHED roof:
Type of material for the Asphalt
PITCHED roof:
Provide any additional House
detail here on the
description of work. (Is
this for a house or
garage? Etc)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
11
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Name of Applicant Alex Knoll
Email not displaying correctly? View it in your browser.
12
CLIENT AGREEMENT
�"i m-NJN-,/ `\/-XTERIOR
**11111*111100 S
7808 Cherry Creek South Dr. Suite 401, Denver, CO 80231
Office: (720) 536-8870 1 www.TheEndeavorTeam.com I Licensed & Insured
Client
I Street Address
City, State, Zip
Email Date
t) I
Endeavor Rep
r
Insurance Company Insurance Agent
(�11 �Ctti��
Home Phone ti Work Phone Claim #
w 5 - a L -LA5 u s Lis �z-c i
Mortgage Company (only if mortgage company is present on payment)
Lender Loan # ❑ Borrow Authorization Form Signed
❑ Photo of Mortgage Check Taken
0 Limited Lifetime Labor Warranty Gen. Liability/Workers' Comp 0 BBB Accredited `No Deposit Required
ROOF SCOPE: Full Partial Repair WINDOWS: Full Partial Repair
Brand:��
Color:
Metal Color:
Felt: w �
i
GUTTERS:( Ful Partial Repair
Color. utters
d ❑Downspouts
Brand:
Model/Color:
SIDING: Full Partial . Repair
I Brand:
Style:
Color:
Payment Terms
Client understands and agrees their insurance company will not pay the deductible
amount or any upgrade client is opting to pay for. Client's expense for these items are:
First payment will be collected when work begins or material delivered - whichever
occurs first. This is partial compensation for labor and materials. This amount is:
Work to be completed according to the specifications in the total amount of:
`l__I
PAINT: Full artial Repair
Brand: i
Color(s):
OTHER:
Bralance due upon substantial completion F1 CASH SALE []Contingency Agreement (Contingent upon Ins. approval)
LJ INSURANCE AGREEMENT. The client authorizes Endeavor Exteriors to represent their best interest in pursuit of full replacement costs for damages believed
to be covered under homeowner's Insurance and allows Endeavor Exteriors to deal directly with the Insurance company regarding this claim This contract does not obligate
the client to Endeavor Exteriors until the claim is approved by the insurance company. and accepted by Endeavor Exteriors Upon approval of claim. Endeavor Exteriors
will complete all specified work at a price agreeable to the insurance company (RCV) and Endeavor Exteriors with no additional cost to the client except for the deductible
Ordinance and Law (supplemental) items may increase the original (RCV) amount Final agreed upon price will become the final contract price and request that all payments
be made payable to Endeavor Exteriors Inc Endeavor Exteriors will not collect payment until the work has begun or materials have been delivered.
*Credit card payments are not accepted on insurance claims*
I (we) agree, by signing below, to all the contract conditions on both front and back, of this agreement
Client Signature: Date of Acceptance: _iiL 3h
.t , / r`
Client Signature: Endeavor Signature:' i
The terms on the back of this contract have been rev d w h me and I (we) agree to them;
Client Initials:
I. If the client plans to use the proceeds of a property and casualty insurance policy pursuant to part I of
article 4 of title 10, C.R.S., to pay for the roofing work, pursuant to section 6-2-105, the roofing contractor
cannot pay, waive, rebate, or promise to pay, waive, or rebate all or part of any insurance deductible
applicable to the insurance claim for payment for work on the covered residential property.
2. All Contracts subject to approval by Endeavor Exteriors financial department.
3. Contract price is valid for thirty (30) days.
-1. Endeavor Exteriors reserves the right to perform specified work in accordance with generally accepted
construction guidelines, while adhering to local codes in erect at the time of contract.
3. All checks must be made payable to: Endeavor Exteriors.
6. All excess materials remain the property of Endeavor Exteriors.
Client is responsible for Homeowner's Association approval of products and colors.
Client acknowledges Endeavor Exteriors as a general contractor, as such Endeavor Exteriors will be
entitled to ten percent (10%) overhead, and ten percent (10%) profit, (O&P) if approved by the insurance
company, if this project is part of a claim.
9. An account is defined as past due when 10 days have elapsed from the date of completion of work. Past
due accounts will earn interest at a rate of one and one-half percent (1.5%) per month or eighteen percent
(18%) annually. If Endeavor Exteriors is required to turn the matter over to an attorney for collection, the
client also agrees to pay all costs incurred, including attorney's fees.
I ��. ShOUld default of payment occur on this contract, Endeavor Exteriors reserves the right to place a
mechanic's lien on the clients' property.
1 1. Endeavor Exteriors shall not be held liable for failure of performance due to labor controversies, strike,
fire, hail, weather, inability to obtain material from usual source, or any other circumstance beyond the
control of the company.
12. Our standard workmanship warranty for roofing is non-transferable limited lifetime, and one (1) year for all
other trades, and the company will provide a service call for roof inspection, as long as the client owns the
property.
13. Endeavor Exteriors is not responsible for any leaks or water damage below the roofline caused by
excessive wind, ice or hail during the period of the warranty.
1 1. Undeavor Exteriors shall refund any deposit if this contract is cancelled within 72 hours (3 days).
15. If this contract is cancelled by the client, after three (3) or more days of execution, the client agrees to
Pay Endeavor Exteriors twenty percent (20%) of the contract price, set by the insurance company, only if
materials have been delivered or work has been performed, as liquidated damages. "Ibis payment is not a
penalty, but is fair and just compensation for services rendered to that point.
16. The homeowner may cancel this contract within 72 hours if the insurer has denied, in whole or part, the
homeowners claim that relates to this contract.
1 -7.
While we make every effort to ensure there are limited consequences of construction, Endeavor Exteriors
will not be held responsible for slight scratching or denting of gutters, droplets of oil in the driveway,
cracks in concrete, or damage to plants and trees. Furthermore, Endeavor Exteriors will not be held
responsible for exterior damages such as deteriorated trim pieces, crown molding, stucco, solar panels,
evaporative coolers, existing skylights, or interior damage such as falling dust and debris, cracked plaster,
sheet rock or nail pops, as a result of normal re-roofing.
18. Replacement or repair of the deteriorated decking, fascia boards, swamp coolers, ventilators, chimneys,
counter flashing, or any other- work completed for the homeowner not explicitly stated in this contract,
are not included in quoted price and will be charged as extra on a time and material basis.
19. Endeavor Exteriors holds the right to photograph all projects in which it is invloved, and the right to
publish throughout all Endeavor Exteriors' social media outlets.
► _ City of Wheat Ridge
Residential Roofing PERMIT - 201707997
PERMIT NO: 201707997 ISSUED: 10/04/2017
JOB ADDRESS: 2880 Newland ST EXPIRES: 10/04/2018
JOB DESCRIPTION: Residential Re -roof to install asphalt shingles - 37 sq Pitch = 8/12
(3rd party inspector required)
*** CONTACTS ***
OWNER (303)905-7082 DAHL THAD C
SUB (720)536-8870 Chris Falasco 160159 Endeavor Exteriors
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: R-3 / Residential
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 21,827.81
FEES
Total Valuation 0.00
Use Tax 458.38
Permit Fee 394.50
** TOTAL ** 852.88
*** COMMENTS ***
*** CONDITIONS ***
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required for both the midroof and final inspections. The 3rd party inspection report AND
THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat
Ridge. The report MUST BE SIGNED by the Homeowner.
REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec.
R806. The installation of ridge venting requires the installation or existence of soffit
venting. For calculation purposes, one hat or turtle vent equal to one-half of one square
foot of opening.
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name) roof
covering" is required to be on site at the time of final inspection.
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped
off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the
Homeowner.
► City of Wheat Ridge
Residential Roofing PERMIT - 201707997
PERMIT NO: 201707997 ISSUED: 10/04/2017
JOB ADDRESS: 2880 Newland ST EXPIRES: 10/04/2018
JOB DESCRIPTION: Residential Re -roof to install asphalt shingles - 37 sq Pitch = 8/12
(3rd party inspector required)
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and ll work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
6 eel l7
Signature of OWNER prTCONTRACTOR (Circle one) Date
1. This permit was issue ased on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2, This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of Wheat Ridge
Residential Roofing PERMIT - 201702875
PERMIT NO: 201702875 ISSUED: 06/29/2017
JOB ADDRESS: 2880 Newland ST EXPIRES: 06/29/2018
JOB DESCRIPTION: Residential Re -roof to install Atlas Pinnacle Pristine asphalt shingles
with 44 sq.
*** CONTACTS ***
OWNER (303)905-7082 DAHL THAD C
SUB (303)296-1353 Randy Howard 020789 Colorado Exteriors, LLC
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: R-3 / Residential
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11,308.00
FEES
Total Valuation 0.00
Use Tax 237.47
Permit Fee 236.00
** TOTAL ** 473.47 PAID
*** COMMENTS *** --
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding A% -inch exists. Asphalt shingles are required to
be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is
required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturera€lls installation
instructions, whichever is more stringent. In order to pass a final inspection of
elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer's technical representative stating that "the application of the roof at
(project address) has been applied in accordance with the installation instruction for
(roof material brand name) roof covering" is required to be on site at the time of final
inspection.
City of Wheat Ridge
Residential Roofing PERMIT - 201702875
PERMIT NO: 201702875 ISSUED: 06/29/2017
JOB ADDRESS: 2880 Newland ST EXPIRES: 06/29/2018
JOB DESCRIPTION: Residential Re—roof to install Atlas Pinnacle Pristine asphalt shingles
with 44 sq.
[, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I an the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am leggally authorilgd to include all entities named within this document as parties to the work to be
performed and that all work to be pertormedasscj scl¢sed in this document and/or Its' �ccom0anying approved plans and specifications.
Signature of OWNER or,' CONTRACTOR (CirNone)l Date
1. This permit was issued ba�od..an the.infrmation, vtded in the permit application and accompanying dans and specifications and is
sub
ject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans
and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4, No work of any manner shall be performed that shall results in a change. of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6, The issurMZCe granting of a e mit shall t be construed to be a permit for, or an approval of, an violation of any provision of any
applicable c r a n n t6Lr uta n of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us
between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line.
Dan Schultz 01 7 6 Z ��
From: Cindy Winograsky <office@coloradoexteriors.net>
Sent: Thursday, June 29, 2017 11:08 AM p
To: Dan Schultz C
Subject: FW: Online Form Submittal: Residential Roofing Permit Application
O
From: no-reply(ci.wheatridge.co.us [maiIto:no-rem@ci.wheatridge.co. us]
Sent: Thursday, June 8, 2017 8:36 AM I
To: office@coloradoexteriors.net
Subject: Online Form Submittal: Residential Roofing Permit Application
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT
IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME
WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your
contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit. Permits are currently being
processed within 24-48 hours, subject to change based on volume.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Existing permits that require amendments (for example, to add
redecking) must be completed in person at City Hall. All other non -roofing permits
must be completed in person at City Hall. The Building Division will be open from
7:30-10:30 a.m., Monday through Friday to process these types of requests.
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number
Property Owner Email
Address
2880 Newland St.
Kelli Dahl
303.905.7082
elitekkdd(c_hotmail.com
Do you have a signed Yes
contract to reroof this
property?
It will need to be
provided at the time of
permit pick-up.
CONTRACTOR INFORMATION
Contractor Name
Contractor's License
Number (for the City of
Wheat Ridge)
Contractor Phone
Number
Colorado Roofing Specialists
303.296.1353
Contractor Email Address off iceCcDcoloradoexteriors. net
(permit pick-up
instructions will be sent
to this email)
DESCRIPTION OF WORK
Is this application for a Yes
new permit for a
residential roof?
Are you re -decking the No VZ
roof?
Description of Roofing Asphalt - Atlas Pinnacle Pristine
Material /
How many squares of 44
material?
Provide additional detail Tear off existing down to deck - replace with new - 7/12 Pitch -
here on the description of 2 -Stories
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
Project Value (contract 7M09 --
value
MOSvalue or cost of ALL l
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
0)
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant Randy Howard
,-T
j
ACCREDITED
BUSINESS Adfil
B8� Physical Address:
747 Sheridan Blvd., Suite 1A
C®L®R.A.�Q nERIORS Lakewood, CO 80214
www.coloradoexteriors.co Main: 303-296-1353
LICENSED GENERAL CONTRACTORS" Fax: 303-232-3353
Property Owner (Customer) Name: �� .iiwk L, Date:'
Property Address:Street#: r V -int City: KF' L �` State:y ZiIli
--Date of Birth:
/_ Home Phone:. Celt Ph.: GL'�x r E-Mail:eii
/Business Phone: j -% `t.'s 7'�' Business Name and Address: Ple ,
(641—
Property
Owner`s I uraoice Company: �([
Claim#: Si2,0
Date of Loss: <` Type of Loss:
f
I authorize Colorado Exteriors, L C (thy, ',Companyto°wsi directly with my insurance com yon nbeb
alf and to fumish all material and labor as listed below.
Company Representative: CJCe-€. Phone #:
Total Amount of Estimate $ i- f'y ( 1219 (Agreed upon price with the Insurance Com based on damages known at time of estimate.)
The owner's out of pocket expenses will not exceed insurance deductible in the amount of $ %10(! 0 (unless upgra s are added or otherwise
as provided in this Contract), Progress payments Cgirtract ROpe s be made as follows: A 6L/ C1 � (2, A'L v ( 0 ,
Policy Specifications: Non -Recoverable Depreciation f (Initial) Recoverable Depreciation (Initial) Code Up -Grade Coverage (initial)
Approximate Dates of Service/Payment Your project will begin on or about (subiect to the Company receiving approval
from Owner's insurance Company, and is expected to be completed within days from delivery of materials, subject to delays for weather,
delays in obtaining materials or permits, or other events beyond the Company's reasonable control. Final payment is due to the Company upon substantial
completion of work. All insurance supplement payments invoiced to Owner's Insurance Company to correct shortages in original estimate will be paid to the Company.
We will furnish the following materials and labor as listed below:
Tear off all layeys,of existing roof material:( layers)
New Shingle: 51 i i,Un i *QQVt Initial
Shingle Color. { Initial `',/
install Felt Paper to Match Existing: X 15 lb
Install Pipe Jacks 3/1 4.1
\•Install Furnace Vents 3x5 5x7 7x9
Fascia Color: �- E7 C> it & - it A I 0 z'
Protect all Landscaping, Pools, A/C Units
aint Vents to Match Roofing Material
Haul Off Trash/Debris and Magnetic Sweep
Other (
Special Instructions:- ✓ `\ Cc>0 E_P(- 1Z C— Ik j ^AA
9
The following Special Provisions Apply Only to Roofing Work on Residential Property in Colorado as provided under C.R.S. 6-22-101 et seq.:
• Notice With Respect to Residential Property Located in Colorado as applicable under C.R.S. 6-22-101 et seq.: Property Owner may rescind roofing contract
pursuant to Section 6-22-104, Colorado Revised Statutes.
• Notice With Respect to Residential Property Located In Colorado as applicable under C.R.S. 6-22-101 et seq.: if Property Owner plans to use the proceeds
of a property and casualty insurance policy issued pursuant to Part 1 of Article 4 of Title 10, Colorado Revised Statutes, to pay for the roofing work, pursuant to
Section 6-22-105, C.R.S_, the roofing contractor cannot pay, waive, rebate, or promise to pay, waive, or rebate all or part of any insurance deductible applicable
to the insurance claim for payment of roofing work on the covered residential property.
• Notice With Respect to Residential Property Located in Colorado as applicable under C.R.S. 6-22-101 et seq_: THE COMPANY SHALL HOLD IN TRUST
ANY PAYMENT FROM THE PROPERTY OWNER UNTIL THE COMPANY HAS DELIVERED ROOFING MATERIALS AT THE RESIDENTIAL PROPERTY
SITE OR HAS PERFORMED A MAJORITY OF THE ROOFING WORK ON THE RESIDENTIAL PROPERTY.
Notice With Respect to Residential Property Located In Colorado as applicable under C.R.S. 6-22-101 et seg.: Property Owner may rescind this
Contract Pursuant to Section 6-22-104, Colorado Revised Statutes.
• Notice: If Property Owner's Insurance Company does not approve scope of work and price within 60 days from date of this Contract, either the Company
or the Property Owner may cancel this Contract upon issuance of written notice to the other party at which time any deposit paid by Property Owner will be
refunded in full and bath parties relieved from any obligations under this Contract.
• Company's Liability insurance (or Surety) Carrier- United Specialty Insurance Company Phone No.: 303-674-5501
Please read the reverse for additional Terns and Conditions which are part of this Contract.
r
By signing,this Contract y6h are authorizing the Company to perform the work as specified and to make payments as required herein.
Property OWner(( us/to er �" The an .
Colorado Ex eriors, LLep_ Signature
~
i
V,
F
,
;
i
~
!
,
Building Permit
C1TY OF WHEAT RIDGE
7506 West29TH Avenue
Whestridge, CO 80033
303-235-2855
,b
r~dvmde+ea~e ,
Residential Roofing
Pernilt Number 19225
9/19/2005
Inspectfon Line
303-234-5933
PROPERTY yggp N¢Wland St Unit:
owxER: patrick Williams (303) 239-9599
Descriptloa '
Remove all old shingles if two or more layers per 2003 IRC section 9. All shingles must meet 110 mPh
` wind load. Will use Elk Shingle
r, en, firroa tP<s mc+i ~tactuer shcli bs t
nni'1 ,reertinnwhcehspeC{J'y
to meet
110 tL1e':1 three secnnd wind gust---IBC (90 <viPH wzrad 1ocu1-O.iJC).
vph ~ ~ aoey; r-3 Walls: Roof: . Stories: SqFeet: 0
IWtW 'dbqucnpropoxdbytlJ~penoitOpplieAtlonmrt.ewnle,aoddoeotvlobteapplk.bleoNio~na4rvY+urnRWtlouo(OeCLLyJ
- mb or rctltletloo~ otnceN; W~t tll menurtmmu ~howq aod a9eiMp^^, .°e m-aunh; ehat Ihrve reW ud ~pee lo ~bNle by
~y:~ M ~pplkatlov, aod Nat I uavme tW rmponeOWty far eompll~oa wkh Ihe Whe~t Rid¢e Hv11dIVC CaEe N.B.C.) and aYOWa apptlrabk
pW ~ rwarlcmGUWYpermint
~ . ~ ! 1 'o J
17W p~4k wa Yud In ueord~vee wlth Ne provhbv ut forth In yow ~pplic~fbn mtl 6~ubjec[ b Ne 6w~ o(Ne SYte o(Cobndo ~vd lo the Zosh~
]levdWou nd 6uMWZ Cade of WAe.t Ride0. Cobndo ar aoy oWtt .pplkWle or0lomen of Ne Ciry. Z '17tl~ psrWl d~i expin V(A) Ne worle suthorittd 4 vot rnmmeneed wlthio ~taty (60) daY~ from luue Ntt or (B) Ne bu0d~o` ~eth~rlaed 6 aoryaded w
obadeaN W.a perbJ af /SU dayx
3 IIthYpeaWtopirµanee Pe^itmry0em9ubvd frofaofono-bWftheomomtaorma0yrtqu4ed,prevWMeorAaeeaWVebeeeorwl9bemWeMNe
~ oelsWlplaor, aodopatliembm aedanY+aPm^d^oorabanCOmentbuootesreMedonc(1)Yam.lfetiooLu+rem'deori(wepeWOOaA+edooment .
. . lisee4me(1)yev.fdRnehallbePV4foranewPerm14
{ Nawu4ef.oYdtoN~oll OedonethatwWChangeNenoturdMwofwaWUValn6adralo+teProbkm.
3. . CaatrwlardvB.wlllyNeHuWInCfie^Pmem, t`venty-four(20)hovnloaEVaottforaONryertioeeaodAaNreWvewriMm~pprvv.l aeWpactlmeutlbefore
proeeWiqwkh iureeNVe PEwue ot WeJob.
~ 6 7hpyaydop,s(* Lii, aetl~pecNC~tbovalWlnot becoetlrvedWbevpumltkr,awaoapprovalof,uyvbktlouofthe
' p- ycadaer ~ntt.hw.mkorrtquWtbn.
~D
4 e . SIGNFD DATE
Ma~day, ber 19, 2005 Page 1 of 1
Building Permit
CTTY OF WHEAT RIDGE
7500 West 291T-I Avenue
Wheatridge, CO 80033
303-235-2855
{ , 4$
■
eilyefVM~ux,fadye i
Residential Roofing
Permit Number
19225
9/ 19/2005
Inspection Line
303-234-5933
PROPERTY 2880 Newland St Unit:
owrvEa: patrick Williams (303) 239-9599
Descripfion .
Remove all old shingles if two or more layers per 2003 IRC section 9. All shingles must meet 110 mph
wind load. Will use Elk Shingle
Authorized By guilding Approval
Authorized On
Zoning
9/I9/2005 Approved By Croot
Monday, September 19, 2005 Page l of I
DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 05~-
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE Date :9/j gl s
7500 WEST 29TH AVENUE p
WHEAT RIDGE, CO 80215
PropertyOwner:
Properry Address : ;~ee0
ConVactor License No. : /~~y 5
Company :
OWNER/CONTRACTOR
ConsWction Value :
Permit Fee :
Use Tax :
AGREEMENT
I hereby certify that the setback distances proposed by this pertnit appiiotion are accurate,
and do not violate applicable ordinances, niks or regulations of the City of Wheat Ridge or
covenants, easements or restrictions o( record; that all measurcments shown, and allegations
made are aecureta; that I have read and ayree to abide by all conditions printed on this
apD~iration, and that I assume lull resp nsibilR'y for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other appliwbeat RidgA ordinanims, for work under this cermd.
(OWNER)(CONTRACTOR)
Description : ,~~uut
O
Approval:
Zoning :
Mf8t~'9
Approval:
enm rmnrurR nez ff fff rAfilkno
Approval:
SIC : Sq. FL :
I Occupancy : Walls : Roof : Stories : Residential Units :
Electrical License No : Piumbing License No : Mechanical License No :
Company : Company : Company :
Expiretion Date : Expiration Date : Expiration Date :
Approval: Approval: Approval:
(1) This pertnil was IssueO in aaortlance wiN Uw proWsians sel IoM In yopur aDpliration aM is subjed W the laws d Uq Sirie d Cobrado aM W the 2oni
Regulauons anE BuiWin9 CoCe of 4Meat Ridpe, Cabndo w any otner applipDle orainancea ot the Ciry. ng
(7) Thia pemM afqY e:pre d(A) the wqk auUwnzeO le rql cartvnenced wMin sixty (60) tlays hom issue Eate or (8) IM buiWirp aulfarixed b fuspenAed or
aEarMOrkM Iw a peAOd a1120 days.
(7) II tnis pemN a:pires, a Mw pemut may be acqutred lor a(ee W ono-haH Ne amoum ronreiry reQuiieE, proviAeE rw Uunges have been u wiil Oe made M the
aqinai plans anC spedficatlons and afry auSpenabn a aCanaonment tus not excee0ed one (t) year. II charpes are ma0a a it wspenaion a aeanawuoent
ecCeeda one (1) year, NO laa shall tM paW lofa new pemvL
No woifc ol any manner shall ba done that will Uwnqe ihe natural Ibw o( waler musing a Enina9e yoWem
5) Contraclor s1uU nofify the Buildlnp InspeUor Iweny.lour (2q taurs in aEvance la ae mspections an0 shail receive written approval on Wpection aN belue
pnceeaiinq wiN suaessNepha xa ol lheIob.
(6) Tha is~ance ol a peimil w the eppovel o(Arawinqs anE speri~iations shail not De consuueE to be a pemiit for, nor an approrat W. arry vloytlon d the pwisbna
Winq oo0as a ury otMt pdinarce, law, rWe or repuWUOn.
Chief Building Inspector For Mayor
Use:
Phone:~3'~3g-%Sy /
Phone :5i~37-A5 7S 3 /
Total: $0.00.
BUILOING DEPARTMENT USE ONLY
THIS PERMIT VALIO ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION