HomeMy WebLinkAbout3830 Newland Streeti CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: (cb, Job Address: c!) r—_ -L_0 C 4,4&4"� ' Permit Number: "2<Z) i srd) I z f� ❑ No one available for inspection: Tint Re -Inspection required: Yes When corrections have been Date: In at M *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal ownof the property end am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I�uer attest that I legall authorized to include all entities named within this document as parties to the work to be performed r%1fiat all w rk to pertor ed is disclosed in this document a d/or its' accompanying approved plans and specifications. /l e V. Signature f OWNER r CO TRACT0* (Circle one) Date 1. This permit was issued bas�d on thonformation provided in the permit application and accompanying plans and specifications and is subject to the compliance h-th'o`se documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of amanner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit ho lnyder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordman or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Residential Solar PERMIT - 201901215 PERMIT NO: 201901215 ISSUED: 06/14/2019 JOB ADDRESS: 3830 Newland St EXPIRES: 06/13/2020 JOB DESCRIPTION: Solar PV installation, roof -mount, flush mount, grid -tied 5.22 sq, 18 panels, no structural required *** CONTACTS *** OWNER (303)908-1690 COWLING MICHELLE R SUB (303)577-9628 Andy Nyman 070159 Sunrun Installation Srvs. Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,761.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal ownof the property end am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I�uer attest that I legall authorized to include all entities named within this document as parties to the work to be performed r%1fiat all w rk to pertor ed is disclosed in this document a d/or its' accompanying approved plans and specifications. /l e V. Signature f OWNER r CO TRACT0* (Circle one) Date 1. This permit was issued bas�d on thonformation provided in the permit application and accompanying plans and specifications and is subject to the compliance h-th'o`se documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of amanner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit ho lnyder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordman or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ON, (A W hca-t I idc. Fc COMMUNriy DFVLI.OI'MFN_l' Building & Inspection Services 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits _ci.wheatridge.co.us FOR OFFICE USE ONLY Date: 31 ) Plan/Pennit�l/ J f q00 I Plan Review Fee: DD Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3830 Newland St Wheat Ridge CO 80033 Property Owner (please print): Randal Cowling Phone: 303-908-1690 Property Owner Email: Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Contractor Name: Sunrun Installation Services City of Wheat Ridge License #: 070159 Phone: Phone: 303-577-9628 Contractor E-mail Address: colorado.permitting@sunrunhome.com For Plan Review Questions & Comments (please print): CONTACT NAME (please print): Thomas M. Brook Phone: 720-537-0235 CONTACT EMAIL(p/ease print): thomas.brook@sunrun.com Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields. ❑COMMERCIAL ® RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Roof -mount, flush mount, grid -tied 5.22 kW Solar PV Sq. FULF BTUs Gallons Amps Squares For Solar: 5.22 Kw 18 # of Panels no Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: _ Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) 9761 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provide plication. CIRCLE ONE: (OWNER)ONTRACTOR o (AUTHORIZED RESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): DATE: ZGI Printed Name: Thomas M. Brook ZONING COMMMENTS: Reviewer: BUILDI G D ARTMENT COMMENTS: Revi wer: t! ^(`¢g PUBLIC WORKS COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: REC TWINPEAK SERIES PREMIUM SOLAR PANELS 100% MADE IN SINGAPORI REC TwinPeak 2 Series solar panels feature an innovative design with high panel efficiency and power output, enabling customers to get the most out of the space used for the installation. Combined with industry-leading product quality and the reliability of a strong and established European brand, REC TwinPeak Z panels are ideal for residential and commercial rooftops worldwide. INTEGRATED MANUFACTURING IN SINGAPORE WAFERS t ry M 1 Measrgnents»mmlhl Y _ _ 1675325 (619420.11 91013581..__ -+--381-5[5051__.. ❑ -,900(351 + a it ❑ 0 11302 K(0.43 2081 2osto (07820.08]1200[471 _ r - _- .-. _ 4S[151 A �3s[751 Nomina(Power-P,,PP(Wp) 275 280 285 290 295 Watt Class Sorting -(W) 0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage -V,,,,,IV) 31.5 31.7 31.9 32.1 32.3 Nominal Power Current-I,,,,P(A) 8.74 8.84 8.95 9.05 9.14 Open Circuit Voltage-Va(V) 38.2 38.4 38.6 38.8 39.0 Short Circuit Current- Isc(A) 9.52 9.61 9.66 9.71 9.76 Panel Efficiency(%) 16.5 16.8 17.1 17.4 17.7 Values at standard test conditions STC (airmass AM I.S. irradiance 1000 W/m2, cell temperature 2S°C). At low irradiance of 200 W/m' (AM 15 and cell temperature 25`C) at least 95% of the STC modu[e efficiency will be achieved. `Where xxx indicates the nominal power class (P_) at STC above, and can be followed by the suffix BLK for black framed modules. ELECTRICAL DATA Nominal Power-P,,,(Wp) 206 210 214 218 223 Nominal Power Voltage-V,,,(V) 29.2 29.4 29.6 29.8 30.0 Nomina(PowerCurrent -IMPP(A) 7.07 7.15 7.24 7.32 7.43 Open Circuit Voltage -Voc (V) 35.4 35.6 35.8 36.0 36.2 Short Circuit Current-ISc(A) 7.52 7.59 7.68 7.75 7.85 Nominal operating cell temperature NOCT (800 W/m', AM 15, windspeed 1 m/s, ambient temperature 20"C). 'Where xxx indicates the nominal power class (P.) at STC above, and can be followed by the suffix BLK for black framed modules. CE Ed OVE cOus UL 1703, Fire classification Type 2: IEC 61215, IEC 61730, IEC 61701 (Salt Mist -severity level 6). IEC 62804 (PID Free), IEC 62716 (Ammonia Resistance), ISO 11925-2 (IgnitabilityClass 1), UNI 8457/9174 (Class A), ISO 90012015,ISO MOI, OHSAS 18001 10 year product warranty 25 year linear power output warranty (max. degression in performance of 0.7%p.a. from 97%after the first year) See warranty conditions for further details. EFFICIENCY YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY qrY*F�US IMPORT DUTY FREE Nominal operating cell temperature(NOCT) 44.6°C(t2"C) Temperature coefficient of P,, -0.36%/°C Temperature coefficient ofVcc -0.30%/°C Temperature coefficient ofI.,0.066%/°C GENERALDATA Cell type: 6 strings of 20 REC HC multicrysta[line PERC Glass: 0.13"(3.2 mm) solar glass with anti -reflective surface treatment Back sheet: Highly resistant polyester polyolefin construction Frame: Anodized aluminum (Available in silver or black) Junction box: IP67 rated, 3 -part with 3 bypass diodes 12 AWG (4 mm2) PV wire, 35"+47" (0.9 m+1.2 m) Connectors: St6ubliMC4PV-KBT4/PV-KST4. 12 AWG (4 mm2) Origins: Silicon: Made in USA & Norway Wafer/Cell/Module: Made in Singapore 0 perational temperature: -40...+185°F(-40...+85°C) Maximum system voltage: 1000V Design Loads: (+j 75.2 tbs/ft2 (3600 Pa) (-) 33.41bs/ft2 (1600 Pa) Refer to installation manual Max series f use rating: 20A Max reverse current: 20A u; MECHANICALDATALL Dimensions: 65.9 x 39.25 x 1.5 (1675 x 997 x 38 mm) Area: 1798 ft" (1.67 m2) r- 0 Weight: 40.8 lbs (18.5 kg) o z NotelSpecificationssubject tochange without notice. REC www.recgroup.com Sin Phase Inverter Witgle HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US APPLICABLE TO INVERTERS WITH PART NUMBER OUTPUT SEXXXXH-XXXXXBXX4 Rated AC Power Output 3800 @ 240V 3000 6000 @ 240V 5000 11400 @ 240V ! 7600 10000 VA Maximum DC Power @240V 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 7750 3300 @ 208V 5000 @ 208V 10000 @ 208V Yes AC Output Voltage Min. -Nom. -Max. Maximum Input Voltage 480 Vac (211 - 240 - 264) Nominal DC Input Voltage 380 400 Vdc AC Output Voltage Min. -Nom. -Max. 8.5 10.5 13.5 16.5 20 27 30.5 Vac 083 - 208 - 229) - 9 1 - 13.5 - 27 Adc AC Frequency (Nominal) 59.3 - 60 - 60.5n Hz Maximum Cont mous Output 12.5 16 21 25 32 42 47.5 A Current @240V 600ksa Sensitivity j Maximum Inverter Efficiency Maximum Continuous Output 16 24 - 48.5 A Current @208V % Nighttime Power Consumption < 2.5 Power Factor 1, adjustable -0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds i INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 :, - 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(4 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @20BV0 - 9 1 - 13.5 - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ksa Sensitivity Maximum Inverter Efficiency 9999.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W m For other regional settings please contact SolarEdge support m A higher current source may be used; the inverter will limit its input current to the values stated Single Phase Inverter Wit HD -Wave Tec n0 ogy for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(l) Inverter Commissioning with the SetApp mobile application using built-in Wi-H station for local connection Rapid Shutdown - NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size /AWG Range 3/4' minimum / 14-6 AWG 3/4' minimum /14-4 AWG �� DC Input Conduit Size / # of Strings / AWG Range 3/4' minimum / 1-2 strings / 14-6 AWG 3/4- minimum / 1-3 strings / 14-6 AWG I Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38.8 / 17.6 Ib / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(x) j 'F / -C Protection Rating NEMA 4X (Inverter with Safety Switch) of Revenue grade inverter P/N: S6o=H-USOOOBNC4 w Full power up to at least WC / 122'F; for power de -rating information refer to: httpsV/www.solarLdge.com/sirtes/defauVfiles/se-temperature-derating-mte-na.pdf O SolarEdge Technologies, Inc AN rights reserved SOIAREDGE, the SolarEdge logo, OPTIMIZED 8V SOIAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc Al Ro H S other trademarks mentioned herein are trademarkowners, Date- of their respective Date 1/2019/V01/ENG NAM. Subject to change without notice. so l a r' • • z SolarEdge Power Optimizer Module Add -On for N +k A or 111Ul P300 / P320 / P370 / P400 / P405 g ^ W P370 -- �- i P300 P320 (frhigher-power P400 P405 (for 60 -cell mod- (for high-power 60 and 72 -cell (for 72 & 96-celli (for thin film ules) 60 -cell modules) modules) modules) j modules) INPUT Rated Input DC Powertt) C 405 W .............................300......... Absolute Maximum Input Voltage .........320......... .........370......... .........400..... .... ...... (Voc at lowest tem erature48 60 80 125 Vdc MPPT Operating Range 8 - 48 8-60 8 - 80 12.5 -105 ..... ..................... ...................... Y.. Vdc Maximum Short Circuit Current (Isc) ............I.. ...... ............ .... 10 11 10.1 ......... ....................................................... ..................... 0...................... .. Adc Maximum DC Input Current 12 5 13.75 12..63 J? .................................................................. .............. Adc Maximum Efficiency 99.5 .............. % Weighted Efficiency......................... ................................................................... 98 :8 ......................................... % Overvoltage Category II .............. OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 ....................................................................................... ............... .... I......... / ft..... ..................... Maximum Output Voltage 60 85 .....q.d..c...... Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OF Safety Output Voltage per Power IP68 /NM................................................ A6. ................................................ Optimizer 1 Vdc STANDARD COMPLIANCE EMC ......................... I .............. .............. ....... _...... FCC Part15Class B,IEC61000.6.2,IEC61000-6-3 ............... PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(2113) HD -WAVE Safety ...................................... ........ ................ .......... IEC62109-1 (class II safety), UL1741 ...................................... .............. RoHS Yes .............. INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage ............. 1000 .............................................................................................................. Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters .............. Dimensions (WxLxH)128x152x27.5/Sx5.97x1.08 128x152x35/ 128x152x50/ mm/in /in 5x5.97x1.96 Wei ht (Includln cables ......�............ g.......) ................................................630.1:4...... ......8 1.1.9. ... ...................... ...... 750.�1:�...... ...... 845.�1:9...... ... ...fir/Ib.... Input Connector .................................. MC4 Compatible MC4 / MC4 Compatible .... AH4..... .......... ............................. I.. Double Insulated; .............. Output Wire Type / Connector Double Insulated; MC4 Compatible MC4 / Double Insulated; MC4 Compatible .................... Amphenol AH4 .. ............................. OutputWire Length .........................................0:95 / 3 :� ................. .............................1:? / 3.9 ............................. .... I......... / ft..... Operating Temperature Range ........................ 40.:+85/:40-+185 ................................... ............... ...m 'C .............. Protection Ratin g....................................................................................... IP68 /NM................................................ A6. ................................................ Relative Humidity ................................ 0-100 .............. y, t'I Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(2113) HD -WAVE Minimum String Length Power 0 mlzers tl 8 10 18 ........................... ............................ Maximum String Length .............. (PowerO timlzers25- 25 — — 50— ....................................... Maximum Power per String 5700 (6000 with 5250 6000 12750 .............. W Parallel Strings of Different Lengths . . . . . . or Orientations .................................. Yes ......... ................... ................................................................ 10 For detailed string sizing information mferto: http://www.solamdge.wm/sites/default/files/string_sizing-na.pdf. ................ .............. Isl it is not allowed to ma P405 with P300/P370/P400/P600/P700 in one string. solar =@@ SolarEdge Power Optimizei Module Add -On For North Ameri P300 / P320 / P370 / P400 / P405 PV power optimization at the module -level ® Up to 25% more energy — Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading ® Flexible system design for maximum space utilization — Fast installation with a single bolt ® Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety USA -CANADA -GERMANY -ITALY -FRANCE -JAPAN-CHINA -AUSTRALIA -THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTHAFRICA-BULGARIA -INDIA www.solaredge.us 'DocuSign Envelope ID: E969A5FC-8818-4AD9-B64C-7A389822BEAD a,sunrun' June 11, 2019 Subject: Structural Certification for Proposed Residential Solar Installation. Job Number: 501R-83000WL; Plan Set: Rev A, Dated 6/10/2019 Client: Randal J Cowling Address: 3830 Newland St, Wheat Ridge, CO, 80033 Attn: To Whom It May Concern A field observation was performed to document the existing framing of the above mentioned address. From the field observation, the existing roof structure was observed as Composition Shingle roofing over roof plywood supported by 2x6 Rafter @ 24" OC. The roof is sloped at approximately 22 degrees and has a max rafter span of 13'4" between supports. Design Criteria: • 2012 International Building Code Basic Wind Speed Vult = 105 mph (Vasd = 82 mph), Exposure C Ground Snow Load = 30 psf After review of the field observation report, the existing roof framing supporting the proposed solar panel layout has been determined to meet or exceed the requirements based on our structural capacity calculations in accordance with applicable building codes. Therefore, no structural upgrades are required. If you have any further questions on the above for mentioned, please do not hesitate to call. Sincerely, Jason Brown, P. Civil Engineer Sunrun, Inc CDocuSignedpby: lkti 18CA9954A699"F... 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 DocuSign Envelope ID: E969A5FC-8B18-4AD9-B64C-7A389822BEAD a,sunrun" Structural Calculations for the Randal J Cowling Residence PV Installation Date: Job Address: Job Number: Scope of Work 6/11/2019 3830 Newland St Wheat Ridge, CO, 80033 501R-83000WL These calculations are for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Calculation Index Sheet Description 2 Structural Geometry, Live Load, Snow Load, Wind Load, & Dead Load 3 Roof (1) Framing Check 4 Roof Attachment Check, Seismic Check, & Scope of Work Engineering Calculations Summary Code: 2012 International Building Code ASCE 7-10 Snow Load: S = 30 psf Live Load: LL = 20 psf Wind: Wind Speed Ult. (V) = 105 mph Exp. = C PV Dead Load: DPV = 3.0 psf Sincerely, Jason Brown, P.E Civil Engineer Sunrun, Inc by: �ti --. '--- ...J9944F... 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.383.0993 DocuSign Cnvelope ID: E969A5FC-8B18-4AD9-B64C-7A389822BEAD Engineer: JRB OM1' Date: 6/11/2019 Job: 501R-83000WL Address: 3830 Newland St Wheat Ridge, CO, 80033 2 of 4 Structrure Geomet Mean Roof Height, h" = 12 ft Eave Height, he = 8 ft Buiding Length, L = 45 ft Building Width, B = 25 ft Module Area = 20 ft2 Roof Pitch, 0 = 22 degrees Live Load: 0.80 Roof Live Load, Lr = 20.00 psf Equation 4.8-1 Snow Load: Ground Snow Load, pg = 30 psf Fig. 7-1 Snow Importance Factor, k = 1 Table 1.5-1 Thermal Factor, Ct = 1.1 Table 7-3 Exposure Factor, Ce = 0.9 Table 7-2 Roof Slope Factor, C5 = 0.80 Figure 7-2c Flat Snow Load, Pf = 20.8 psf Equation 7.3-1 Sloped Roof Snow Loads, Ps = 16.6 psf Equation 7.4-1 Is the width of the roof > 20ft? Yes GCp = Drift Height, hd = 1.44 ft Figure 7-9 Roof slope for a rise of one, S 2.48 -18.96 Unbalanced Width = 6.02 ft Fig 7-5 y = 18 pcf Equation 7.7-1 Unbalanced Snow Load = 32.96 psf Fig 7-5 Wind Load: 9.60 9.60 Basic Wind Speed (3s -gust), V = 105.0 mph Figure 26.5-3A Building Occupancy Category = 2 Walls - Exterior Table 1.5-1 Exposure Category = C Wood Sec 26.7.3 Topographic Factor, Kzr = 1.00 2x4 Studs @ 16" Equation 26.8-1 Velocity Pressure, qh = 20.39 Gypsum Equation 30.4-1 Edge Zone, a = 3.00 ft Figure 30.5-1 Uplift (0.6W) Zone 1 (psf) Zone 2 (psf) Zone 3 (psf) GCp = -0.84 -1.55 -2.43 Table 30.4-2 P30.4 =.6 x qh x GCPzone = -10.28 -18.96 -29.67 Equation 30.4-1 Downward (0.6W) GCp = 0.43 0.43 0.43 Table 30.4-2 P30.4 =.6 x qh x GCPzone = 9.60 9.60 9.60 Equation 30.4-1 Dead Load: Roof (1): Roof Walls - Exterior Composition Shingle 3.0 psf Wood 5.0 psf 5/8 OSB Sheathing 2.0 2x4 Studs @ 16" 2.0 2x6 Rafter @ 24" OC 1.0 Gypsum 3.0 Misc. (Ceiling, Insulation, etc.) 1.0 Misc. (Insulation, etc.) 2.0 PV System, Ppv 3.0 Total Roof DL = 10.0 psf Total Wall DL = 12.0 psf 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 DocuSign Envelope ID: E969A5FC-8B18-4AD9-B64C-7A389822BEAD Engineer: JRB T°' Date: 6/11/2019 Job: 501 R-83000 W L Address: 3830 Newland St Wheat Ridge, CO, 80033 3 of 4 Roof (1) Framine Check Roof Framing = 2x6 Rafter @ 24" OC Timber Species = Doug Fir -Larch #2 Max Beam Span = 13.32 ft b = 1.5 in d = 5.50 in Moment of Inertia, Ix = 20.80 in Section Modulus, Sx = 7.56 in Bending Stress, Fb = 900 psi Elastic Modulus, Emin = 580000 psi Wood Adjustment Factors PV Tributary Width, Wpv = PV Tributary Length, Lpv = PV Tributary Area, At = PV Dead Point Load, PD = Ppvx At = Roof Distributed Load, wDL = Load Case: 0.6DL + 0.6W (CD =1.6) Roof Zone = Pup = Pnet x At + 0.6 x PD x cos(9) = Mb(wind—up) = Fb' (wind) = Fb XCD XCLS XCM xCt XCL XCF xCfu XCi xCr = Mallowable = Sx X Fb' (wind) = Load Case: DL + 0.6W (CD =1.6 Pdown = PnetX At + PD X COS(e) = Mb(wind_down) = Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu XCi XCr = Mallowable = Sx X Fb' (wind) = Load Case: DL + 0.75(0.6W) + 0.75S (CD =1.6 Roof Snow Distributed Load, wSL = Psnow = Ps At = Mb(wind_snow) = Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu xCi XCr = Mallowable = Sx X Fb' (snow) = CD (Wind) CD (Snow) CLS CM Ct 1.60 1.15 1.15 1.00 1.00 CL CF Cfu Ci Cr 1.00 1.30 1.00 1.00 1.15 3.30 ft 4.0 ft 13.2 ftZ 37 Ib 13 plf 1 114 Ib 245 Ib -ft 2476 psi 1560 lb -ft > 245 OK 163 Ib 837 Ib -ft 2476 psi 1560 lb -ft > 837 OK 42 plf 204 Ib 1244 Ib -ft 2476 psi 1560 lb -ft > 1244 OK Load Case: DL + S (CD =1.15) Roof Snow Distributed Load, wSL = 42 plf Psnow = Ps x At = 204 Ib Mb(snow) = 1095 lb -ft Fb' (snow) = Fb XCD XCLS XCM XCt XCL XCF XCfu xCi XCr = 1779 psi Mallowable = Sx x Fb' (snow) = 1121 Ib -ft > 1095 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 OK DocuSign Envelope ID: E969A5FC-8B18-4AD9-B64C-7A389822BEAD Engineer: JRB TM Date: 6/11/2019 Job: 501R-83000WL Address: 3830 Newland St Wheat Ridge, CO, 80033 4of4 Rafter Attachments: 0.6D+0.6W (Zone 21 Puplift = At x Pnet = 228 Ib Connector Uplift Capcity per SnapNRack Test Results = 600 Ib 5/16" Lag Screw Withdrawl Value = 266 Ib/in Lag Screw Penetration = 2.5 in Allowable Capacity with CD = 1064 Ib Seismic Check: > 228 OK Table 11.2A - NDS > 228 OK 7olncrease = (wtotal + Warray) / Wtotal = 22247 *100%-100% = 4.37% ** 21315 **The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on applicable building codes, professional engineering inspection and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 Existing Dead Load: Solar Dead Load: Aroofexisting = 1125 ft2 Wpanel = 42 lb Wroofexisting = 7875 Ib NUmpanel = 18 Awallexisting = 1120 ft2 Wpanel_tot = 756 Ib Wwallexisting = 13440 lb Wbos = 176 lb Motel = 21315 lb Warray = 9321b 7olncrease = (wtotal + Warray) / Wtotal = 22247 *100%-100% = 4.37% ** 21315 **The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on applicable building codes, professional engineering inspection and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 5220W DC, 5000W AC • ALL WORK SHALL COMPLY WITH NEC 2017, IBC, MUNICIPAL CODE, AND ALL SOLAR MODULES PV -1.0 COVER SHEET • MODULES: (18) REC SOLAR: REC290TP2 BLK MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. OSE SERVICE ENTRANCE • INVERTER(S): • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV -2.0 SITE PLAN (1) SOLAREDGE TECHNOLOGIES: SE5000H-US WITH • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV -3.0 LAYOUT REVENUE GRADE METERING • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY MP MAIN PANEL PV -4.0 ELECTRICAL • RACKING: GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. SNAPNRACK RL; FLASHTRACK COMP. SEE DETAIL • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SNR B MOUNT SD -00708 • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SP SUB -PANEL SNR A MOUNT PV -5.0 SIGNAGE • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. Q PV LOAD CENTER ® CHIMNEY • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). SM SUNRUN METER ATTIC VENT • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. V� • • 9.71 AMPS MODULE SHORT CIRCUIT CURRENT. 15.17 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a) & 690.8 (b)]. PM n FLUSH ATTIC VENT DEDICATED PV METER '00� Y. � 1 iL J PVC PIPE VENT iCo�uHrr�r INV INVERTER(S) WITH ® METAL PIPE VENT INTEGRATED DC A�"S APPROVED DISCONNECT AND AFCI ® T -VENT Reviewed for Code ComoNaM AC AC DISCONNECT(S) SATELLITE DISH � Notes: 1)Verify or provide supplemental ground rod or 2017 NEC Art. 250.53(A)(2). DC DC DISCONNECT(S) FIRE SETBACKS Mans Examinerpx• Y_Y_dfi^*: rhe rods per 2) Natural Gas piping to be bonded s per 2017 NEC Art. 250.104(8). =B HARDSCAPE COMBINER BOX E2 ...�� Old carnpwor%a,s Shan nw he o atonic for, Oran awo ejef mviobro•to 3)Bond P/V panels to the building Grounding -� wsiom fdw resu rotogiveo wmytutvWWeaea ditPryasw,res.nawua � mov � o� ro�`�g#WtWw0"V"°n`°/"" `' Electrode System per 2017 NEC Art. 690(A). INTERIOR EQUIPMENT —PL— PROPERTY LINE rales a oche, adwnces of the city rheunot be wtid. L SHOWN AS DASHED SCALE: NTS sunrun A AMPERE AC ALTERNATING CURRENT AFCI AZIM ARC FAULT CIRCUIT INTERRUPTER AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT EC #7080, ME #30603 _ Re Y (E) EXT EXISTING EXTERIOR 6040 WEST 91 ST AVENUE, WESTMINSTER, CO 80031 PHONE 303.577.6527 Univ FRM FRAMING FAX 303.577.9629 CUSTOMER RESIDENCE: W52ndAve INT INTERIOR LBW LOAD BEARING WALL RANDAL J COWLING WSMAve MAG MAGNETIC 3830 NEWLAND ST, WHEAT MSP MAIN SERVICE PANEL RIDGE, CO, 80033 (N) NEW NTS NOT TO SCALE TEL. (303) 908-1690 W4GthAve OC ON CENTER APN #: 24810 Lakeside PRE -FAB PRE -FABRICATED >*, anh Ag v BERKELEY PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: 501 R-83000WL PV PHOTOVOLTAIC 3830 Newland Street TL TRANSFORMERLESS DESIGNER: (415) 580-6920 ex3 I2r P ICAL V OPTS BRETT FINKELSTEIN W 38th Avc W 38th Atte W WATTS SHEET REV NAME DATE COMMENTS Wheat Ridge W35tfiAve T COVER SHEET W 32nd Avg? REV: A 6/10/201 ti.� 24th t.fL W a+?tr Ave PAGE PV -1.0 ARRAY TRUE MAG PV AREA SITE PLAN - SCALE = 3/32" = 1'-0" PITCH AZIM AZIM (SQFT) ® (E) GATE AR -01 22° 180° 171 ° 53.9 (N) ARRAY AR -03 AR -02 22° 90° 81° 215.7 AR -03 22° 270° 261- 53.9 (E) RESIDENCE FIRE SETBACKS FIRE SETBACKS (T TYP) (18" TYP) PL PL L PL PL PL PL v AC � � r Q MP SE PM � INV co �s z QJ r sunrun p D A D. .a o D p D D EC #7080, ME #30603 6040 WEST 91ST AVENUE, WESTMINSTER, CO 80031 yJ PHONE 303.577.6527 v FAX 303,577.9629 r CUSTOMER RESIDENCE: RANDAL J COWLING 3830 NEWLAND ST, WHEAT RIDGE, CO, 80033 TEL. (303) 908-1690 PL PL PL PL p/- PL PL PL PL AP #: 24810 PROJECT NUMBER: (E) FENCE 501 R-83000WL N ARRAY AR -02 010% ( ) (415) 580-6920 ex3 (N) ARRAY AR -01 great'onp DESIGNER: `V`S,00 BRETT FINKELSTEIN SHEET SITE PLAN REV: A 6/10/2019 PAGE PV -2.0 DocuSign Envelope ID: E969A5FC-8B18-4AD9-B64G7A3898ZZBEAU ROOF FRAME FRAME MAX FRAME OC ROOF EDGE MAX PEN MAX MoD. DESIGN CRITERIA ROOF TYPE MOUNTING DETAIL ROOF HEIGHT EXPOSURE MATERIAL FRAME TYPE SIZE SPAN SPACING ZONE SPACING OVERHANG MODULES: AR -01 COMP SHINGLE FLASHTRACK COMP. SEE DETAIL SD -00708 1 STORY ATTIC WOOD RAFTER 2 X 6 13'- 0" 24" 3' 4' - 0" 2' - 0" REC SOLAR: REC290TP2 BLK AR -02 COMP SHINGLE FLASHTRACK COMP. SEE DETAIL SD -00708 1 STORY ATTIC WOOD RAFTER 2 X 6 11' - 9" 24" 3' 4'- 0" 2' - 0" MODULE DIMS: 65.94" x 39.25" x 1.49" (38mm) AR -03 COMP SHINGLE FLASHTRACK COMP. SEE DETAIL SD -00708 1 STORY ATTIC WOOD RAFTER 2 X 6 111-91, 24" 3' 4'- 0" 2' - 0" MODULE CLAMPS: Portrait: 8.2" - 16.4" D1 - AR -01 - SCALE: 3/16" = 1'-0" D2 - AR -02 PITCH: 22° - SCALE: 1/8" = 1'-0" Landscape: 0" - 9.75" MAX DISTRIBUTED LOAD: 3 PSF PITCH: 22° AZIM: 180° AZIM: 90° SNOW LOAD: 30 PSF WIND SPEED: '-3" 105 MPH 3 -SEC GUST. -2'-9"- -2'-9"-t-2'-9"- 2'-10" - LAG SCREWS: �� 5/16"x4.0": 2.5" MIN EMBEDMENT 2' 4„ NOTE: - 16'-7" - - 2" '-9- INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED 3, SPANS, AND NOTIFY E.O.R. OF - ANY DISCREPANCIES BEFORE PROCEEDING. 10' PENETRATION SPACING: FULLY STAGGERED ROW SPACING: 6-8 -� 4, TYP 1.00" BETWEEN ROWS 5'-4" I COLUMN SPACING: I 2' —4' TYP- 0.75" BETWEEN COLUMNS 4-9 T 8'-4" 8'-5" " 11-1 sunrun EC #7080, ME #30603 D3 - AR -03 - SCALE: 3/16" = V-0" PITCH: 22° g AZIM: 270° —4'-3"— - - 2'-5" —3'-2"- 6040 WEST 91ST AVENUE, WESTMINSTER, CO 80031 PHONE 303.577.6527 303.577.9629 FAX 303.577.9629 CUSTOMER RESIDENCE: 2 a 3'-8" V a o' RANDAL J COWLING c� 3830 NEWLAND ST, WHEAT 3c RIDGE, CO, 80033 TEL. (303) 908-1690 1'-7 11 n AP #: 24810 PROJECT NUMBER: 10' 501 R-83000WL L/C DESIGNER: (415) 580-6920 ex3 —4' TYP— 4�pt10 A 844 ��Q BRETT FINKELSTEIN SHEET 4'-8" �� I t'' X934-9 ,t gg LAYOUT V-5" I t DocuSigne°� - ,.�. 6/10/2019 - 2'-5" - - 10" T-8" � C ONA /CiNA�ti LPAGE — 3'-2" — V-3.0 P SEE SITE PLAN FOR NORTH ARROW 18CA9954A5994 W. CONDUIT SCHEDULE 120/240 VAC CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE SINGLE PHASE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE SERVICE 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 METER #: Notes: EGC/GEC 4 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 O XCEL 000049403621 1)Verify or provide supplemental ground rod or EGC/GEC rods per 2017 NEC Art. 250.53(A)(2). UTILITY 2) Natural Gas piping to be bonded s per 2017 NEC GRID Art. 250.104(6). - SUPPLY SIDE TAP 3)Bond P/V panels to the building Grounding ,r' Electrode System per 2017 NEC Art. 690(A). 4 1 EXISTING 125A (N) LOCKABLE SOLAREDGE TECHNOLOGIES: C MAIN BREAKER BLADE TYPE (N) LOCKABLE SE5000H-US WITH REVENUE FUSED AC (N) DEDICATED BLADE TYPE GRADE METERING 1 DISCONNECT PV KWH METER AC DISCONNECT 5000 WATT INVERTER JUNCTION BOX PV MODULES 2 OR EQUIVALENT (1) REC SOLAR: REC290TP2 BLK .— EXISTING _ / // (18) MODULES 125A o�.�. M O ops -� `� �-•% o + OPTIMIZERS WIRED IN: —' MAIN _— - (1) SERIES OF (18) OPTIMIZERS FACILITY PANEL 30A FUSES LOADS _ FACILITY GROUND SQUARE D 240V METER SOCKET SQUARE D LOAD RATED DC DISCONNECT D222NRB 200A CONTINUOUS DU221 RB WITH AFCI, RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R, 60A WITH LEVER BYPASS 3R, 30A,2P COMPLIANT P320 120/240VAC [MAX 10' FROM 120/240VAC UTILITY METERIMAX 10' FROM UTILITY METER] CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC 4 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC MODULE CHARACTERISTICS 5220 W P320 OPTIMIZER CHARACTERISTICS: REC SOLAR: REC290TP2 BLK: 290 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 38.8 V MAX INPUT VOLTAGE: 48 VDC MAX POWER VOLTAGE: 32.1 V MAX INPUT ISC: 11 ADC SHORT CIRCUIT CURRENT: 9.71 A MAX OUTPUT CURRENT: 15 ADC SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: 5220 W SYSTEM OPEN CIRCUIT VOLTAGE: 18 V SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 13.74 A SYSTEM SHORT CIRCUIT CURRENT: 15 A NOTES TO INSTALLER: 1. 18 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN BREAKER IN MAIN PANEL ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED. 3. FIELD SPLICE WIRE TO APPROPRIATE SIZE FOR MANUFACTURE TERMINATION SPECIFICATIONS WHEN NEEDED. 4. WIRE UPSIZE AT TIME OF INSTALLATION IS PERMISSABLE. 01 of �reatR�d90 ON od" t�a�t�9 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2017: 690.17(E), NEC 2014: 690.17(E), NEC 2011: 690.17(4) &WARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM IWARNING J ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): NEC 2017:690.5(C), NEC 2014: 690.5(C), NEC 2011: 690.5(C) ZEWARNING PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS I ARFI I n(ATInN- 3.5" LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S): NEC 2017: 705.12(B)(2)(3)(b), PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b), NEC 2014: 705.12(13)(2)(3)(c), NEC 2011: NEC 2014: 705.12(D)(3), NEC 2011: 705.12(D)(4) 705.12(D)(4) &WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE C -Y SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2017: 690.56(C)(1)(a) LABEL LOCATION: LABEL LOCATION: ADJACENT TO PV BREAKER (IF UTILITY SERVICE ENTRANCE/METER, APPLICABLE). INVERTER/DC DISCONNECT IF REQUIRED BY PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b), LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: BY LOCAL AHJ. 705.12(D)(7) PER CODE(S): NEC 2017: 690.12, NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1 LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2017:690.31 (G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 INVERTER 1 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2017: 690.53, NEC 2014: 690.53, NEC 2011: 690.53 NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN ^' ^ R PANELS ON ROOF NVERTER (EXT) AC DISCONNECT BREAKER DISCONNE 3830 NEWLAND ST, WHEAT RIDGE, CO, 80033 M IN SNAPNRACK RL FLASHTRACK COMP MOUNTING REVISION: A 6/19/2017 NEW ITEM GTV 5/16" UMBRELLA LAG SCREW MUST EMBED 2-1/2" INTO THE ROOF STRUCTURAL MEMBER/RAFTER _ 5/16" UMBRELLA LAG SCREW FLASHTRACK COMP UMBRELLA GASKET 5/16" STAINLESS STEEL (SHADED GRAY) UMBRELLA LAG SCREW A 2-1/2" MINIMUM EMBEDMENT\ � o ROOFING FLASHTRACK COMP COMP FLASHING (HATCHED) )OF SHEATHING COMPLETED INSTALLATION DETAIL A SECTION VIEW COMP FLASHING SLIP FLASHING UNDER SHINGLE ABOVE ROOFING MATERIAL ROOF RAFTER (TYP.) ROOF ATTACHMENTS SHALL ROOF SHEATHING, UNDERLAYMENT, ALWAYS BE EMBEDDED INTO ROOF RAFTERS OR OTHER AND ROOFING MATERIAL (TYP.) STRUCTURAL MEMBERS FLASHING SHOULD EXTEND TO END OF SHINGLE COURSE FLASHTRACK COMP FLASH TRACK SHOULD BE ORIENTED NO MORE THAN 3 DEGREES FROM PARALLEL TO RAFTER n P1/ICTKIP` AAATCnTAI ROOF DECKING 2-1/2" MIN. EMBEDMENT ow of INTO STRUCTURAL MEMBER Wheat Ricige ng nivis,On COMPLETED INSTALLATION ,Sn(a n ra�n Sunrun South LLC DESIGNER: G.MCPheeters SCALE: NTS \\��J� PART NUMBER: DESCRIPTION: REV l�I] 595 MARKET STREET, 29TH FLOOR • SAN FRANCISCO, CA 94105 USA PHONE (415) 5BM900• FAX (415) 5SM902 DRAFTER: G.Viscuso SD -00708 PENETRATION DETAIL, FLASHTRACK COMP THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY DATE: 6/19/2017 REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE APPROVED BY: G.McPheeters WRITTEN CONSENT OF SUNRUN SOUTH LLC. City of Wheat Ridge E -Res. Furnace Replacement PERMIT - 201900373 PERMIT NO: 201900373 ISSUED: 03/06/2019 JOB ADDRESS: 3830 Newland St EXPIRES: 03/05/2020 JOB DESCRIPTION: Replacement of 70K BTUs,90 percent efficient gas furnace and AC unit 2.5 tons, 16 SEER. Electrical for AC reconnect. *** CONTACTS *** OWNER (303)908-1690 COWLING MICHELLE R SUB (303)466-4209 Rosalie Cooper SUB (303)466-4209 Rosalie Cooper 018111 Cooper Heating & Cooling 018111 Cooper Heating & Cooling *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA I Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,272.00 FEES Total Valuation 0.00 Use Tax 173.71 Permit Fee 188.45 ** TOTAL ** 362.16 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION City of Wheat Ridge E -Res. Furnace Replacement PERMIT - 201900373 201900373 3830 Newland St Replacement of tons, 16 SEER. ISSUED: 03/06/2019 EXPIRES: 03/05/2020 70K BTUs,90 percent efficient gas furnace and AC unit 2.5 Electrical for AC reconnect. f, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am t e legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further attest that I am legally authorized to include al[ entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. �. This permit shall expire 365 days after the date of issuance regardless of activity. Re uests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 1. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. �. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable„code or any ord�� nce or regulation of this jurisdiction. Approval of work is subject to field inspection. >ignature of Chief Building Official Date MQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Lagenia Reimer /6o From: no -reply@ ci.wheatridge.co.us Sent: Wednesday, March 6, 2019 11:54 AM To: CommDev Permits Subject: Online Form Submittal: Residential Furnace/Boiler Replacement Permit Application Categories: Gina Residential Furnace/Boiler Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or BOILER - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes replacement residential furnace or boiler like for like? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address Attach Credit Card Authorization Form - **DO NOT ATTACHED RANDOM FORMS** 3830 Newland St. Randal Cowling 303-908-1690 rcklaatu@yahoo.com newland st. cc authorization. pdf CONTRACTOR INFORMATION Contractor Business Cooper Heating and Cooling _ Name i, 2. ) Contractor's License 018111 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 720-361-4245 Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address kdaniels@coopergreenteam.com Retype Contractor Email Address DESCRIPTION OF WORK kdaniels@coopergreenteam.com What type of unit is being Furnace installed? Number of BTUs What is the efficiency (%) of the unit? Is the unit GAS or ELECTRIC? Where is the furnace or boiler located (for example, basement, crawlspace, etc)? 70000 96 gas crawl space Project Value (contract 5515 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit 2 has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Kathi Daniels Permit Email not displaying correctly? View it in your browser. La enia Reimer ZO 19 00 573 From: no-reply@ci.wheatridge.co.us Sent: Wednesday, March 6, 2019 11:51 AM To: CommDev Permits Subject: Online Form Submittal: Residential Replacement Air Conditioner/Evaporative Cooler Permit Application Categories: Gina Residential Replacement Air Conditioner/Evaporative Cooler Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT AIR CONDITIONER OR EVAPORATIVE COOLER - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential replacement AC or Evaporative Cooler like for like? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address Attach Credit Card Authorization Form - **DO NOT ATTACH RANDOM DOCUMENTS** 3830 Newland St. Randal Cowling 303-908-1690 rcklaatu@yahoo.com newland st. cc authorization. pdf CONTRACTOR INFORMATION 1 Contractor Business Cooper Heating Name Contractor's License 018111 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 720-361-4245 Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address kdaniels@coopergreenteam.com Retype Contractor Email kdaniels@coopergreenteam.com Address DESCRIPTION OF WORK What type of replacement Replacement Air Conditioner unit are you installing? How many tons is the 2.5 unit? For AC - what is the 16 SEER? For Evaporative Coolers, what is the CFMs? Where is the unit located crawl space (for example, rooftop, backyard on ground etc)? Is electrical needed for re- Yes hook? If electrical work is being 018111 ac reconnect performed, you must provide electrical contractor's Wheat Ridge license no. and scope of work. Project Value (contract 2757 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT 2 I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Kathi Daniels Permit Email not displaying correctly? View it in Vour browser. a r , City of Wheat Ridge Residential Roofing PERMIT - 201707628 PERMIT NO: 201707628 ISSUED: 09/25/2017 JOB ADDRESS: 3830 Newland ST EXPIRES: 09/25/2018 JOB DESCRIPTION: Residential Re -roof to install OC asphalt shingles - 16 sq Pitch = 4/12 *** CONTACTS *** OWNER (303)908-1690 COWLING MICHELLE R SUB (303)984-7663 Judy Antener 070171 1-DERFUL ROOF & RESTORATION *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,000.00 FEES Total Valuation 0.00 Use Tax 168.00 Permit Fee 172.60 ** TOTAL ** 340.60 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. City of Wheat Ridge Residential Roofing PERMIT - 201707628 PERMIT NO: 201707628 ISSUED: 09/25/2017 JOB ADDRESS: 3830 Newland ST EXPIRES: 09/25/2018 JOB DESCRIPTION: Residential Re -roof to install OC asphalt shingles - 16 sq Pitch = 4/12 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications= applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be perfo ed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. i ature of OWNER or CONTRACTOR (Circle one) Date This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official andmay be subject to a fee equal to one-half of the original pennit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Budding Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services DIvision in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicab6:2� r any ordina nce or regulation of this jurisdiction. Approval of work is subject to field inspection. �J�J1ls Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett 2b 1707 ( Z, contractors only. This type of permit is ONLY being processed online --do not come From: no-reply@ci.wheatridge.co.us�� Sent: Wednesday, September 20, 2017 11:08 AM varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application your contractor's license or insurance has expired, and you may update those Follow Up Flag: Follow up Flag Status: Completed C C Residential Roofing Permit Application fi c � This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION JL Property Address 3830 Newland St Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Michelle & Randal Crowling 303-908-1690 41 Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract 1 derfulcolleen@gmail.com Yes 17-0278 Crowling2f CONTRACTOR INFORMATION Contractor Business 1-derful Roofing & Restoration Name L Contractor's License 070171 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) 303-984-7663 9858 W Girton Dr Contractor Email Address 1derfulcolleen@gmail.com Retype Contractor Email 1 derfulcolleen@gmail.com Address DESCRIPTION OF WORK TOTAL SQUARES of 16 the entire scope of work: Project Value (contract 8000.00 , value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or No Pitched roof (2:12 pitch or greater) 42 both? (check all that apply) What is the specific pitch of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: Type of material for the PITCHED roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) 4:12 16 OC TruDefinition Duration Storm Asphalt Re -Roof House 15 sqs and Shed 1 sq SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to 43 submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Colleen Jacobsen Email not displaying correctly? View it in your browser. 44 9858 W. Girton Drive Lakewood, CO 80227 Phone: 303-984-ROOF(7663) Fax: 855-696-7776 I DERFUL RQDFING S RESTORATION PROPOSAL Fr,: }j Name:r Q o,,—A,-,) Job Address s City, State, Zip: Phone: `� ^�r—ge,,.� Mailing Address: (if Different) Email Address: Best way to contact: _ --I'fear Off and eaves are open or cl sed. Ins ect Deckin : Dote ted existing decking replaced at cost of $ Per Sq. ner w II be notified if any damaged wood is found during tear off. Install ice shield on eaves and in valley(s) 14-J' c� - r�Install drip edge 2jo Color Ia tall undedayment VVz-,, )CU-� Recover roof with year manufacturer warranty. �'9hingle manufacturer color J-fiNail every shingle install eS ridge style ,-}-iTistall pipe jacks -4-155-d jacks swamp cooler -= 3- �p'flash sidewalls hep flash chimney step flash skylight Derful Roofing & Restoration will provide general liability insurance of at least $2,000,000 and Workers Compensation of at least $500,000 �an up and haul of roofing debris--'I:-;lean out gutters ,,W-agnetic sweep of surrounding area lean around landscaping ,% All required Permits furnished by 1-Derful Roofing & Restoration - to be reimbursed by Insurance Company -Derful Roofing & Restoratipn five year warranty on labor Current Ventilation Recommended -----' C Decline recommendation on ventilation .w.1J `' 1 1 Proposal Date: 6 - D -J % 7 This proposal may be withdrawn by 1-Derful Roofing & Restoration if not accepted within 30 days from the above date. SUBMITTED BY: 1-D ,,RF,!UL ROOFING RATION 1-Derful Rep: LP -t- Cell Phone: "- 7- 7 �3 Insurance Company:'_ Adjustor Information: �- Policy Number: Claim Number: t+ �' . aC3 '7 Coe, v ;I i f-{ Z gutters: color Y-^ Outlet ❑ Siding: D Extra work Special instructions: 1-derful Roofing and Restoration shall hold in trust any payment received from you until 1-derful has delivered roofing materials at the site or has performed a majority of the roofing work on your property. $ 1000,0"" deductible to be collected at time of material delivery. $ 1Z T.D IV,S initial totalclaimamount as of ,% 3 z� /20This price is subject to supplements/adjustments. Roof work to be completed within 21 days of final insurance approval and mortgage endorsement* Date of ept ce f / 1-Derful R In & R ora�tionnRRRepresentative Homeowner's ignature Prope O er is/is not intending to make payment from the proceeds of a property and casualty insurance policy. INSURANCE ALLOWANCE AGREEMENT If so, homeowner must read and sign below. IlWe agree to retain 1-Derful Roofing & Restoration (contractor) to repairfreplace the damaged or entire portion of the property described on this contract contingent upon the contractor obtaining my insurance company's approval and payment to have said work completed. It is agreed that the contractor is empowered to contact my insurance carrier and to meet with their representative in order to negotiate the amount of damage, the cost of the repair or replacement of the damage to the above property. Upon the insurance carrier agreement with the contractor and the dorm payment being made the work will be scheduled and may begin on a first in first out basis. Checks shall be made payable to 1-Derful Roofing & Restoration. In the event that the insurance carrier fails to negotiate in a fair and reasonable marner, the contractor shall not be held liable and this agreement will be void_ The contractor will release the complete file to the Commissioner of Insurance at the customer's request. Insured out of pocket expense will not exceed the insured (purchaser) policy deductible for the work agreed upon between the insurance carrier and the contractor. Insured also agrees to provide all the necessary documentation for the claim (including documentation to facilitate payment from insurance carrier andior mortgage holder). The contractor reserves the right to file for supplemental claims due to material and/or labor increases due to a storm environment or to insurance adjuster's mistakes, errors or omissions. Insurance 1/we agree by signing above to all the contract conditions on both the front and back of this agreement a i CITY OF WHEAT" RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspectin%..Time AM/PM Re -Inspection required: Yes/' No) When corrections have been made, call for re-insp9ctbn at 303-234-5933 Date:C ! �' = a % Inspector: DO NOT REMOVE T NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: �!D Job Address: Permit Number: u/ o I ( �' ❑ No one available for inspection;,Time U AMS Re -Inspection required: Yes No When corrections W/ _/ been made, call for re -inspection at 303-234-593 I3 Date: v( ��l/ Inspector: �%k DO NOT REMOVE THIS NOTICE e i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: R 0 Job Address: 3 %3® k)x- w VA Py S7 - Permit T"Permit Number: D.0/1 Oy 0 q/ ff o v -P D STa,— v s e�rqn h lc ❑ No one available for inspection: Time/U: Z Q AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 t Date: �'%v� l ? Inspector: DO NOT REMOVE THIS NOTICE 4' CITY OF WHEAT RIDGE Building Inspection Division 31 (303) 234-5933 Inspection line ?;r,(303) 235-2855 Office (303) 237-8929 Fax 4. INSPECTION NOTICE Inspection Type: tf` Job Address: ` Permit Number:iixi l f� a." ' a ❑ No one available for inspection: Time 3 AMM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 3 Date: Inspector: DO NOT REMOVE THIS NOTICE COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number Date 16886 4/8/2004 Property Owner: MARCELLA DOZIER / MICHELLE & RANDY COWLING Property Address: 3830 NEWLAND ST Contractor License No. : Company: Phone : 424-6486 Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or reslrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Buildin9 Code (U.B.C.) and all other applirab*W heat Fj1fVgAordinaAces, for work under this pprjnit. i (OW NER)(CONTRACTOR) Construction Value : $360.00 Permit Fee : $30.55 Plan Review Fee : $0.00 Use Tax : $7.20 Total: $37.75 Use: Description : PRIVACY FENCE 47' LONG NORTH SIDE OF BACKYARD. MATERIALS: CEDAR BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval : JH Zoning : R-3 Approval : 415/04 Roof Piease Notz: Owner/contrac[or is responsihic ror I-~^~'~~ ~rcpcr~: lines and constructing impro:,c c!; , approvcd plao aud er,- r_.! The City is r.ot resp n;, _c : 1c subc;it.ed ivit! m h , _.ci ; i, . , ecors resulting Gn!n in.r. .__...:.~r, Approval: Occupancy: Walls Electrical License No : Company: Expiration Date : Approval: Plumbing License No : Company: Expiration Date : Approval: Mechanical License No : Company : Expiration Date : Approval : (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject lo the laws of the State of Colorado and to the Zoning Regulations and Building Code of W heat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work aulhonzed is not commencetl within sixry (60) days fmm issue date or (B) ihe builtling authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-halt the amounl normally required, provided no changes have been or will be matle in the onginal plans and speciflcations and any suspension or abandonment has not exceedad one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, /ull fees shall be paid for a new permit. (4) No work of any manner shall be tlone that will change the natural Flow of water causing a drainage problem. (5) Conlractor shall noti/y the Building Inspedor twenly-(our (24) hours in atlvance for all inspedions and shall receive written approval on inspection card before procaediing with successive phases of the job. (6) The issuance rmit or ihe a proval of tlrewings and specifcations shall not be constmetl to be a permit for, nor an approval of, any violation of ihe .LiLpe provi ' uildi s or an r ordinance, law, rule or regulation. Stories : Residential Units : Chief Building Inspector Please sign Terms and Conditions on reverse side of page o` wNE4r COMMUNITY DEVELOPMENT DEPARTMENT Building Pernvt Number: ^ a BUILDING INSPECTION LI1VE - 303-234-5933 Date: CITY OF WHEAT RIDGE Y' 7500 WEST 29TH AVENUE CD~Oqp~ WHEAT RIDGE, CO 80033 -(303-235-2855) `Ul ~~~~ICATION Property Owner:MARC£IIR At7JEq Mlf,~-°lIE Gawiinrlj~lso~ (~uli'rl Property Address: 3a30 Q&A qop '*T Phone : 3o; q2'( 6((8 6 Conaac[or License No.: Company: Phone: OX\TER/CONTRACTOR SIGNATURE OF GNDERSTMDINC AND ACREEMENT 1 hereby cmify that the sctback distances propostd by this permi[ application are accurztc, and do not violate applicable ordinances, rula or rcgulations of the Ciry of Wheat Ridgc or covenanls, easemrncs or rcstrictions ofrecord; thal all measurements shown, and allcgalions madc arc accurzte; that I havc rcad and agrce to abide by all conditions yrinud on this appliwtion and that 1 assume full rcsponsibiliry for compliancc with thc Whcat Ridge Building Code (U.B.C) and all other applicable Whea1 Ridge Ordinances, (or work undw this pertnit. IO~gCOMRACTOR):SIGNfD l DATE 2 / (OwNERxCOM'RACfOR): PFUMED DAiE DESCRIPTION: Construction Value`$ Permit Fee:$ Plan Review Fee:$ Use Tax:$ TOtfll:$ _PRIUA&q (Euc.E ql' Co;A NoM Sjpf oF BPCY--4Aa T4aTEeiai-5 : cE,Qlp,a BUILDING DEPARTMENT USE ONLY ZONIN6 COMMEN7E: Approval: J~ J/s I 0¢ Zoning: K_3 BUILDIN6 COMMENTS: Approval: PUsuc WoaKS CorMerRS: Approval: SIC: Sq.Ft.: Occupancy: Walls: Roof: Stories: Residential Uniu: Elecaical License No: Plumbing Licerae No: Mechanical License No: Company: CompanY: Company: Expiration Date: Expiration Date: Expuation Date: Approval: Approval: Approval: (I) This permit wu iuued in acmrdance w ith the pmvisions se1 forth in yaur appliuuon md is subjxt m N< laws of the $nle of Cobndo and to the Zoning Regulations and Building Coda of WL<at Ridge, Cobndo wmy otha applkabk ordinancn of ae Ciry. This pemin shall enpirt if(A) the work authorizcd is `wt commenccd rithin sinry (60) days hom iuue dau or (B) the building authorized is susyendcd or abaiMoned frn a period of 120 daya. (3) If Nis permit expires, a neu pemiii may be uquired fw a ke of one-half the amoum nwmally required, pro.ided no clungcs have been or wIO be made m the origind p4ns and specifications uW anY suspcnsion wabandonment has nd exceedd one ( i) yeu. If changes have pttn or if susyatsioa or abandonmrnt exceeds om (1) year, full fees shall be pud tw a ncw peMiL (4) I:o work of any manner WII be don< Ow1 will change ihe nuunl flow of waur nusin8+ dmiMBe 7mbkm. (5) Contru Wr shall norify the BuiWinQ inryecmr iwrnry-four (21) Iwurs in advance for a11 insy«oons and shell receire wrinen appruval on insyecUOn nid beforc proceediny with successive phaus of th<job. (6) T he iuuance of a pertmt ar the approval of dnwings uM specificauons yhall .wt bt conswed a bc a permit f«, nor u appmval of, any no6non of Jw pro,isions of the building codn or any otAer ordinantt, law, ruk or regu6don. Chief Building Inspector 3?30 303 efv4 6-18C, PERMIT: ADDRESS: JOB CODE: INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground vo rroi %.over unaergrouna or tseiow i in-sian work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS /-:� %(02 �r 71 Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous •� Z'�1 Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof'- •� Z'�1 410 Final Window/Door 411 Landscape/Park/Planning Inspections from these entities shall be requested one week in advance. For landscaping and parking inspections please call 303-235-2846 For ROW and drainage inspections please call 303-235-2861 For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works 413 Flood plain Inspection 414 Fire Insp. / Fire Protection 415 Public Works Final 416 Storm Water Mgmt. 417 Zoning Final Inspection 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division.