HomeMy WebLinkAbout3830 Newland Streeti CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: (cb,
Job Address: c!) r—_ -L_0 C 4,4&4"� '
Permit Number: "2<Z) i srd) I z f�
❑ No one available for inspection: Tint
Re -Inspection required: Yes
When corrections have been
Date: In
at
M
*** COMMENTS ***
*** CONDITIONS ***
Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal ownof the property end am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I�uer attest that I legall authorized to include all entities named within this document as parties to the work to be
performed r%1fiat all w rk to pertor ed is disclosed in this document a d/or its' accompanying approved plans and specifications.
/l e
V.
Signature f OWNER r CO TRACT0* (Circle one) Date
1. This permit was issued bas�d on thonformation provided in the permit application and accompanying plans and specifications and is
subject to the compliance h-th'o`se documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of amanner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit ho
lnyder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicable code or any ordman or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of Wheat Ridge
Residential Solar PERMIT -
201901215
PERMIT NO:
201901215
ISSUED:
06/14/2019
JOB ADDRESS:
3830 Newland St
EXPIRES:
06/13/2020
JOB DESCRIPTION:
Solar PV installation, roof -mount, flush mount,
grid -tied 5.22 sq, 18
panels, no structural required
*** CONTACTS ***
OWNER (303)908-1690 COWLING MICHELLE R
SUB (303)577-9628 Andy Nyman
070159 Sunrun
Installation Srvs. Inc.
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE:
UA / Unassigned
SUBDIVISION CODE:
2405 / BARTHS, COULEHAN GRANGE,
WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION:
9,761.00
FEES
Total Valuation
0.00
Residential Solar
500.00
** TOTAL **
500.00
*** COMMENTS ***
*** CONDITIONS ***
Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal ownof the property end am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I�uer attest that I legall authorized to include all entities named within this document as parties to the work to be
performed r%1fiat all w rk to pertor ed is disclosed in this document a d/or its' accompanying approved plans and specifications.
/l e
V.
Signature f OWNER r CO TRACT0* (Circle one) Date
1. This permit was issued bas�d on thonformation provided in the permit application and accompanying plans and specifications and is
subject to the compliance h-th'o`se documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of amanner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit ho
lnyder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicable code or any ordman or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
ON, (A
W hca-t I idc. Fc
COMMUNriy DFVLI.OI'MFN_l'
Building & Inspection Services
7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: permits _ci.wheatridge.co.us
FOR OFFICE USE ONLY
Date: 31 )
Plan/Pennit�l/ J f q00
I
Plan Review Fee: DD
Building Permit Application
*** Complete all applicable highlighted areas on both sides of this form.
Incomplete applications may not be processed. ***
Property Address: 3830 Newland St Wheat Ridge CO 80033
Property Owner (please print): Randal Cowling Phone: 303-908-1690
Property Owner Email:
Tenant Name (Commercial Projects Only)
Property Owner Mailing Address: (if different than property address)
Address:
City, State, Zip:
Architect/Engineer:
Architect/Engineer E-mail:
Contractor Name: Sunrun Installation Services
City of Wheat Ridge License #: 070159
Phone:
Phone: 303-577-9628
Contractor E-mail Address: colorado.permitting@sunrunhome.com
For Plan Review Questions & Comments (please print):
CONTACT NAME (please print): Thomas M. Brook Phone: 720-537-0235
CONTACT EMAIL(p/ease print): thomas.brook@sunrun.com
Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form):
Electrical: Plumbing: Mechanical:
W.R. City License # W.R. City License # W.R. City License #
Other City Licensed Sub: Other City Licensed Sub:
City License # City License #
Complete all highlighted fields.
❑COMMERCIAL ® RESIDENTIAL
Provide description of work: For ALL projects, provide a detailed description of work to be
performed, including current use of areas, proposed uses, square footage, existing condition and
proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.
Roof -mount, flush mount, grid -tied 5.22 kW Solar PV
Sq. FULF
BTUs
Gallons
Amps Squares For Solar: 5.22 Kw 18 # of Panels no Requires Structural
For Commercial Projects Only: Occupancy Type: Construction Type: _
Occupancy Load: Square Footage:
Project Value: (Contract value or the cost of all materials and labor included in the entire project)
9761
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the
truthfulness of the information provide plication.
CIRCLE ONE: (OWNER)ONTRACTOR o (AUTHORIZED RESENTATIVE) of (OWNER) (CONTRACTOR)
Signature (first and last name): DATE: ZGI
Printed Name: Thomas M. Brook
ZONING COMMMENTS:
Reviewer:
BUILDI G D ARTMENT COMMENTS:
Revi wer:
t! ^(`¢g
PUBLIC WORKS COMMENTS:
Reviewer:
DEPARTMENT USE ONLY
OCCUPANCY CLASSIFICATION:
CONSTRUCTION TYPE:
Building Division Valuation:
REC
TWINPEAK
SERIES
PREMIUM SOLAR PANELS
100% MADE IN SINGAPORI
REC TwinPeak 2 Series solar panels feature an
innovative design with high panel efficiency and
power output, enabling customers to get the most
out of the space used for the installation.
Combined with industry-leading product quality
and the reliability of a strong and established
European brand, REC TwinPeak Z panels are ideal
for residential and commercial rooftops
worldwide.
INTEGRATED MANUFACTURING IN SINGAPORE
WAFERS
t
ry
M
1
Measrgnents»mmlhl
Y _ _ 1675325 (619420.11
91013581..__ -+--381-5[5051__..
❑ -,900(351 +
a
it ❑
0 11302
K(0.43 2081
2osto
(07820.08]1200[471 _
r
- _- .-. _ 4S[151
A
�3s[751
Nomina(Power-P,,PP(Wp)
275
280
285
290
295
Watt Class Sorting -(W)
0/+5
0/+5
0/+5
0/+5
0/+5
Nominal Power Voltage -V,,,,,IV)
31.5
31.7
31.9
32.1
32.3
Nominal Power Current-I,,,,P(A)
8.74
8.84
8.95
9.05
9.14
Open Circuit Voltage-Va(V)
38.2
38.4
38.6
38.8
39.0
Short Circuit Current- Isc(A)
9.52
9.61
9.66
9.71
9.76
Panel Efficiency(%)
16.5
16.8
17.1
17.4
17.7
Values at standard test conditions STC (airmass AM I.S. irradiance 1000 W/m2, cell temperature 2S°C).
At low irradiance of 200 W/m' (AM 15 and cell temperature 25`C) at least 95% of the STC modu[e efficiency will be achieved.
`Where xxx indicates the nominal power class (P_) at STC above,
and can be followed by the suffix BLK for black framed modules.
ELECTRICAL DATA
Nominal Power-P,,,(Wp)
206
210
214
218
223
Nominal Power Voltage-V,,,(V)
29.2
29.4
29.6
29.8
30.0
Nomina(PowerCurrent -IMPP(A)
7.07
7.15
7.24
7.32
7.43
Open Circuit Voltage -Voc (V)
35.4
35.6
35.8
36.0
36.2
Short Circuit Current-ISc(A)
7.52
7.59
7.68
7.75
7.85
Nominal operating cell temperature NOCT (800 W/m', AM 15, windspeed 1 m/s, ambient temperature 20"C).
'Where xxx indicates the nominal power class (P.) at STC above,
and can be followed by the suffix BLK for black framed modules.
CE Ed OVE cOus
UL 1703, Fire classification Type 2: IEC 61215, IEC 61730,
IEC 61701 (Salt Mist -severity level 6). IEC 62804 (PID Free),
IEC 62716 (Ammonia Resistance), ISO 11925-2 (IgnitabilityClass 1),
UNI 8457/9174 (Class A), ISO 90012015,ISO MOI, OHSAS 18001
10 year product warranty
25 year linear power output warranty
(max. degression in performance of 0.7%p.a. from 97%after
the first year)
See warranty conditions for further details.
EFFICIENCY
YEAR PRODUCT WARRANTY
YEAR LINEAR POWER OUTPUT
WARRANTY
qrY*F�US IMPORT DUTY FREE
Nominal operating cell temperature(NOCT) 44.6°C(t2"C)
Temperature coefficient of P,, -0.36%/°C
Temperature coefficient ofVcc -0.30%/°C
Temperature coefficient ofI.,0.066%/°C
GENERALDATA
Cell type: 6 strings of 20 REC HC multicrysta[line PERC
Glass: 0.13"(3.2 mm) solar glass with
anti -reflective surface treatment
Back sheet: Highly resistant polyester
polyolefin construction
Frame: Anodized aluminum
(Available in silver or black)
Junction box: IP67 rated, 3 -part with 3 bypass diodes
12 AWG (4 mm2) PV wire, 35"+47" (0.9 m+1.2 m)
Connectors: St6ubliMC4PV-KBT4/PV-KST4.
12 AWG (4 mm2)
Origins: Silicon: Made in USA & Norway
Wafer/Cell/Module: Made in Singapore
0 perational temperature: -40...+185°F(-40...+85°C)
Maximum system voltage:
1000V
Design Loads:
(+j 75.2 tbs/ft2 (3600 Pa)
(-) 33.41bs/ft2 (1600 Pa)
Refer to installation manual
Max series f use rating:
20A
Max reverse current:
20A
u;
MECHANICALDATALL
Dimensions: 65.9 x 39.25 x 1.5 (1675 x 997 x 38 mm)
Area:
1798 ft" (1.67 m2) r-
0
Weight:
40.8 lbs (18.5 kg) o
z
NotelSpecificationssubject tochange without notice.
REC
www.recgroup.com
Sin Phase Inverter
Witgle
HD-Wave Technology for North America
SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/
SE760OH-US / SE1000OH-US / SE1140OH-US
APPLICABLE TO INVERTERS WITH
PART NUMBER
OUTPUT
SEXXXXH-XXXXXBXX4
Rated AC Power Output
3800 @ 240V
3000
6000 @ 240V
5000
11400 @ 240V
! 7600 10000 VA
Maximum DC Power @240V
3300 @ 208V
5000 @ 208V
10000 @ 208V
Maximum AC Power Output
3000 3800 @ 240V
5000 6000 @ 240V
7600 10000 11400 @ 240V
VA
7750
3300 @ 208V
5000 @ 208V
10000 @ 208V
Yes
AC Output Voltage Min. -Nom. -Max.
Maximum Input Voltage
480
Vac
(211 - 240 - 264)
Nominal DC Input Voltage
380
400
Vdc
AC Output Voltage Min. -Nom. -Max.
8.5 10.5
13.5 16.5 20
27 30.5
Vac
083 - 208 - 229)
- 9
1 - 13.5 -
27
Adc
AC Frequency (Nominal)
59.3 - 60 - 60.5n
Hz
Maximum Cont mous Output
12.5 16
21 25
32 42 47.5
A
Current @240V
600ksa Sensitivity
j
Maximum Inverter Efficiency
Maximum Continuous Output
16
24
- 48.5
A
Current @208V
%
Nighttime Power Consumption
< 2.5
Power Factor
1, adjustable -0.85 to 0.85
GFDI Threshold
1
A
Utility Monitoring, Islanding
Protection, Country Configurable
Yes
Thresholds
i
INPUT
Maximum DC Power @240V
4650
5900
7750 9300 11800
15500 17650
W
Maximum DC Power @208V
-
5100
7750
:, - 15500
W
Transformer -less, Ungrounded
Yes
Maximum Input Voltage
480
Vdc
Nominal DC Input Voltage
380
400
Vdc
Maximum Input Current @240V(4
8.5 10.5
13.5 16.5 20
27 30.5
Adc
Maximum Input Current @20BV0
- 9
1 - 13.5 -
27
Adc
Max. Input Short Circuit Current
45
Adc
Reverse -Polarity Protection
Yes
Ground -Fault Isolation Detection
600ksa Sensitivity
Maximum Inverter Efficiency
9999.2
%
CEC Weighted Efficiency
99
99 @ 240V
98.5 @ 208V
%
Nighttime Power Consumption
< 2.5
W
m For other regional settings please contact SolarEdge support
m A higher current source may be used; the inverter will limit its input current to the values stated
Single Phase Inverter
Wit HD -Wave Tec n0 ogy for North America
SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/
SE760OH-US / SE1000OH-US / SE1140OH-US
ADDITIONAL FEATURES
Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)
Revenue Grade Data, ANSI C12.20 Optional(l)
Inverter Commissioning with the SetApp mobile application using built-in Wi-H station for local connection
Rapid Shutdown - NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect
2017 690.12
STANDARD COMPLIANCE
Safety
UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
Grid Connection Standards
IEEE1547, Rule 21, Rule 14 (HI)
Emissions
FCC Part 15 Class B
INSTALLATION SPECIFICATIONS
AC Output Conduit Size /AWG
Range
3/4' minimum / 14-6 AWG 3/4' minimum /14-4 AWG
��
DC Input Conduit Size / # of Strings /
AWG Range
3/4' minimum / 1-2 strings / 14-6 AWG 3/4- minimum / 1-3 strings / 14-6 AWG
I
Dimensions with Safety Switch
(HxWxD)
17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185
in /
mm
Weight with Safety Switch
22110 25.1/11.4 26.2/11.9 38.8 / 17.6
Ib / kg
Noise
< 25 <50
dBA
Cooling
Natural Convection
Operating Temperature Range
-40 to +140 / -40 to +60(x)
j 'F / -C
Protection Rating
NEMA 4X (Inverter with Safety Switch)
of Revenue grade inverter P/N: S6o=H-USOOOBNC4
w Full power up to at least WC / 122'F; for power de -rating information refer to: httpsV/www.solarLdge.com/sirtes/defauVfiles/se-temperature-derating-mte-na.pdf
O SolarEdge Technologies, Inc AN rights reserved SOIAREDGE, the SolarEdge logo, OPTIMIZED 8V SOIAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc Al Ro H S
other trademarks mentioned herein are trademarkowners, Date- of their respective Date 1/2019/V01/ENG NAM. Subject to change without notice.
so l a r' • • z SolarEdge Power Optimizer
Module Add -On for N +k A
or 111Ul
P300 / P320 / P370 / P400 / P405
g ^ W P370 -- �-
i P300 P320
(frhigher-power
P400 P405
(for 60 -cell mod- (for high-power
60 and 72 -cell (for 72 & 96-celli (for thin film
ules) 60 -cell modules) modules) modules)
j modules)
INPUT
Rated Input DC Powertt)
C 405
W
.............................300.........
Absolute Maximum Input Voltage
.........320......... .........370......... .........400.....
.... ......
(Voc at lowest tem erature48
60 80 125
Vdc
MPPT Operating Range
8 - 48 8-60 8 - 80 12.5 -105
..... ..................... ...................... Y..
Vdc
Maximum Short Circuit Current (Isc)
............I.. ......
............ ....
10 11 10.1
......... ....................................................... ..................... 0......................
..
Adc
Maximum DC Input Current
12 5 13.75 12..63
J? ..................................................................
..............
Adc
Maximum Efficiency
99.5
..............
%
Weighted Efficiency.........................
................................................................... 98 :8 .........................................
%
Overvoltage Category
II
..............
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current 15
....................................................................................... ...............
.... I.........
/ ft.....
.....................
Maximum Output Voltage 60 85
.....q.d..c......
Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OF
Safety Output Voltage per Power
IP68 /NM................................................
A6. ................................................
Optimizer
1
Vdc
STANDARD COMPLIANCE
EMC ......................... I ..............
.............. ....... _...... FCC Part15Class B,IEC61000.6.2,IEC61000-6-3
...............
PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V
A SOLAREDGE INVERTER(2113) HD -WAVE
Safety ......................................
........ ................
.......... IEC62109-1 (class II safety), UL1741 ......................................
..............
RoHS
Yes
..............
INSTALLATION SPECIFICATIONS
Maximum Allowed System Voltage
.............
1000
..............................................................................................................
Vdc
Compatible inverters
All SolarEdge Single Phase and Three Phase inverters
..............
Dimensions (WxLxH)128x152x27.5/Sx5.97x1.08
128x152x35/ 128x152x50/
mm/in
/in
5x5.97x1.96
Wei ht (Includln cables
......�............ g.......) ................................................630.1:4......
......8 1.1.9. ...
...................... ...... 750.�1:�...... ...... 845.�1:9......
...
...fir/Ib....
Input Connector
..................................
MC4 Compatible MC4 / MC4 Compatible
.... AH4..... .......... .............................
I..
Double Insulated;
..............
Output Wire Type / Connector
Double Insulated; MC4 Compatible MC4 / Double Insulated; MC4 Compatible
....................
Amphenol AH4 .. .............................
OutputWire Length .........................................0:95
/ 3 :� ................. .............................1:? / 3.9 .............................
.... I.........
/ ft.....
Operating Temperature Range
........................ 40.:+85/:40-+185
................................... ...............
...m
'C
..............
Protection Ratin g.......................................................................................
IP68 /NM................................................
A6. ................................................
Relative Humidity ................................
0-100
..............
y,
t'I Rated STC power of the module. Module of up to +5% power
tolerance allowed.
PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V
A SOLAREDGE INVERTER(2113) HD -WAVE
Minimum String Length
Power 0 mlzers
tl
8 10 18
........................... ............................
Maximum String Length
..............
(PowerO timlzers25-
25 — — 50—
.......................................
Maximum Power per String
5700 (6000 with 5250 6000 12750
..............
W
Parallel Strings of Different Lengths
. . . . . .
or Orientations ..................................
Yes
......... ................... ................................................................
10 For detailed string sizing information mferto: http://www.solamdge.wm/sites/default/files/string_sizing-na.pdf.
................
..............
Isl it is not allowed to ma P405 with P300/P370/P400/P600/P700
in one string.
solar =@@
SolarEdge Power Optimizei
Module Add -On For North Ameri
P300 / P320 / P370 / P400 / P405
PV power optimization at the module -level
® Up to 25% more energy
— Superior efficiency (99.5%)
Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading
® Flexible system design for maximum space utilization
— Fast installation with a single bolt
® Next generation maintenance with module -level monitoring
— Module -level voltage shutdown for installer and firefighter safety
USA -CANADA -GERMANY -ITALY -FRANCE -JAPAN-CHINA -AUSTRALIA -THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTHAFRICA-BULGARIA -INDIA www.solaredge.us
'DocuSign Envelope ID: E969A5FC-8818-4AD9-B64C-7A389822BEAD
a,sunrun'
June 11, 2019
Subject: Structural Certification for Proposed Residential Solar Installation.
Job Number: 501R-83000WL; Plan Set: Rev A, Dated 6/10/2019
Client: Randal J Cowling
Address: 3830 Newland St, Wheat Ridge, CO, 80033
Attn: To Whom It May Concern
A field observation was performed to document the existing framing of the above mentioned
address. From the field observation, the existing roof structure was observed as Composition
Shingle roofing over roof plywood supported by 2x6 Rafter @ 24" OC. The roof is sloped at
approximately 22 degrees and has a max rafter span of 13'4" between supports.
Design Criteria:
• 2012 International Building Code
Basic Wind Speed Vult = 105 mph (Vasd = 82 mph), Exposure C
Ground Snow Load = 30 psf
After review of the field observation report, the existing roof framing supporting the proposed
solar panel layout has been determined to meet or exceed the requirements based on our
structural capacity calculations in accordance with applicable building codes. Therefore, no
structural upgrades are required.
If you have any further questions on the above for mentioned, please do not hesitate to call.
Sincerely,
Jason Brown, P.
Civil Engineer
Sunrun, Inc
CDocuSignedpby: lkti
18CA9954A699"F...
133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993
DocuSign Envelope ID: E969A5FC-8B18-4AD9-B64C-7A389822BEAD
a,sunrun"
Structural Calculations for the Randal J Cowling Residence PV Installation
Date:
Job Address:
Job Number:
Scope of Work
6/11/2019
3830 Newland St
Wheat Ridge, CO, 80033
501R-83000WL
These calculations are for the existing roof framing which supports the new PV modules as
well as the attachment of the PV system to existing roof framing. All PV mounting equipment
shall be designed and installed per manufacturer's approved installation specifications.
Calculation Index
Sheet Description
2 Structural Geometry, Live Load, Snow Load, Wind Load, & Dead Load
3 Roof (1) Framing Check
4 Roof Attachment Check, Seismic Check, & Scope of Work
Engineering Calculations Summary
Code: 2012 International Building Code
ASCE 7-10
Snow Load: S = 30 psf
Live Load: LL = 20 psf
Wind: Wind Speed Ult. (V) = 105 mph Exp. = C
PV Dead Load: DPV = 3.0 psf
Sincerely,
Jason Brown, P.E
Civil Engineer
Sunrun, Inc
by:
�ti
--. '--- ...J9944F...
133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.383.0993
DocuSign Cnvelope ID: E969A5FC-8B18-4AD9-B64C-7A389822BEAD
Engineer: JRB
OM1' Date: 6/11/2019
Job: 501R-83000WL
Address: 3830 Newland St
Wheat Ridge, CO, 80033
2 of 4
Structrure Geomet
Mean Roof Height, h" =
12 ft
Eave Height, he =
8 ft
Buiding Length, L =
45 ft
Building Width, B =
25 ft
Module Area =
20 ft2
Roof Pitch, 0 =
22 degrees
Live Load:
0.80
Roof Live Load, Lr = 20.00 psf Equation 4.8-1
Snow Load:
Ground Snow Load, pg =
30 psf
Fig. 7-1
Snow Importance Factor, k =
1
Table 1.5-1
Thermal Factor, Ct =
1.1
Table 7-3
Exposure Factor, Ce =
0.9
Table 7-2
Roof Slope Factor, C5 =
0.80
Figure 7-2c
Flat Snow Load, Pf =
20.8 psf
Equation 7.3-1
Sloped Roof Snow Loads, Ps =
16.6 psf
Equation 7.4-1
Is the width of the roof > 20ft?
Yes
GCp =
Drift Height, hd =
1.44 ft
Figure 7-9
Roof slope for a rise of one, S
2.48
-18.96
Unbalanced Width =
6.02 ft
Fig 7-5
y =
18 pcf
Equation 7.7-1
Unbalanced Snow Load =
32.96 psf
Fig 7-5
Wind Load:
9.60
9.60
Basic Wind Speed (3s -gust), V =
105.0 mph
Figure 26.5-3A
Building Occupancy Category =
2
Walls - Exterior
Table 1.5-1
Exposure Category =
C
Wood
Sec 26.7.3
Topographic Factor, Kzr =
1.00
2x4 Studs @ 16"
Equation 26.8-1
Velocity Pressure, qh =
20.39
Gypsum
Equation 30.4-1
Edge Zone, a =
3.00 ft
Figure 30.5-1
Uplift (0.6W)
Zone 1 (psf)
Zone 2 (psf)
Zone 3 (psf)
GCp =
-0.84
-1.55
-2.43 Table 30.4-2
P30.4 =.6 x qh x GCPzone =
-10.28
-18.96
-29.67 Equation 30.4-1
Downward (0.6W)
GCp =
0.43
0.43
0.43 Table 30.4-2
P30.4 =.6 x qh x GCPzone =
9.60
9.60
9.60 Equation 30.4-1
Dead Load:
Roof (1):
Roof
Walls - Exterior
Composition Shingle
3.0 psf
Wood
5.0 psf
5/8 OSB Sheathing
2.0
2x4 Studs @ 16"
2.0
2x6 Rafter @ 24" OC
1.0
Gypsum
3.0
Misc. (Ceiling, Insulation, etc.)
1.0
Misc. (Insulation, etc.)
2.0
PV System, Ppv
3.0
Total Roof DL =
10.0 psf
Total Wall DL =
12.0 psf
133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993
DocuSign Envelope ID: E969A5FC-8B18-4AD9-B64C-7A389822BEAD
Engineer: JRB
T°' Date: 6/11/2019
Job: 501 R-83000 W L
Address: 3830 Newland St
Wheat Ridge, CO, 80033
3 of 4
Roof (1) Framine Check
Roof Framing
= 2x6 Rafter @ 24" OC
Timber Species
= Doug Fir -Larch #2
Max Beam Span
= 13.32 ft
b
= 1.5 in
d
= 5.50 in
Moment of Inertia, Ix
= 20.80 in
Section Modulus, Sx
= 7.56 in
Bending Stress, Fb
= 900 psi
Elastic Modulus, Emin
= 580000 psi
Wood Adjustment Factors
PV Tributary Width, Wpv =
PV Tributary Length, Lpv =
PV Tributary Area, At =
PV Dead Point Load, PD = Ppvx At =
Roof Distributed Load, wDL =
Load Case: 0.6DL + 0.6W (CD =1.6)
Roof Zone =
Pup = Pnet x At + 0.6 x PD x cos(9) =
Mb(wind—up) =
Fb' (wind) = Fb XCD XCLS XCM xCt XCL XCF xCfu XCi xCr =
Mallowable = Sx X Fb' (wind) =
Load Case: DL + 0.6W (CD =1.6
Pdown = PnetX At + PD X COS(e) =
Mb(wind_down) =
Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu XCi XCr =
Mallowable = Sx X Fb' (wind) =
Load Case: DL + 0.75(0.6W) + 0.75S (CD =1.6
Roof Snow Distributed Load, wSL =
Psnow = Ps At =
Mb(wind_snow) =
Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu xCi XCr =
Mallowable = Sx X Fb' (snow) =
CD (Wind) CD (Snow)
CLS
CM
Ct
1.60 1.15
1.15
1.00
1.00
CL CF
Cfu
Ci
Cr
1.00 1.30
1.00
1.00
1.15
3.30 ft
4.0 ft
13.2 ftZ
37 Ib
13 plf
1
114 Ib
245 Ib -ft
2476 psi
1560 lb -ft > 245 OK
163 Ib
837 Ib -ft
2476 psi
1560 lb -ft > 837 OK
42 plf
204 Ib
1244 Ib -ft
2476 psi
1560 lb -ft > 1244 OK
Load Case: DL + S (CD =1.15)
Roof Snow Distributed Load, wSL = 42 plf
Psnow = Ps x At = 204 Ib
Mb(snow) = 1095 lb -ft
Fb' (snow) = Fb XCD XCLS XCM XCt XCL XCF XCfu xCi XCr = 1779 psi
Mallowable = Sx x Fb' (snow) = 1121 Ib -ft > 1095
133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993
OK
DocuSign Envelope ID: E969A5FC-8B18-4AD9-B64C-7A389822BEAD
Engineer: JRB
TM Date: 6/11/2019
Job: 501R-83000WL
Address: 3830 Newland St
Wheat Ridge, CO, 80033
4of4
Rafter Attachments: 0.6D+0.6W (Zone 21
Puplift = At x Pnet =
228 Ib
Connector Uplift Capcity per SnapNRack Test Results =
600 Ib
5/16" Lag Screw Withdrawl Value =
266 Ib/in
Lag Screw Penetration =
2.5 in
Allowable Capacity with CD =
1064 Ib
Seismic Check:
> 228 OK
Table 11.2A - NDS
> 228 OK
7olncrease = (wtotal + Warray) / Wtotal = 22247 *100%-100% = 4.37% **
21315
**The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis
is required.
Limits of Scope of Work and Liability
We have based our structural capacity determination on applicable building codes, professional engineering inspection and design
experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel
installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and
procedures.
133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993
Existing Dead Load:
Solar Dead Load:
Aroofexisting
= 1125 ft2
Wpanel
= 42 lb
Wroofexisting
= 7875 Ib
NUmpanel
= 18
Awallexisting
= 1120 ft2
Wpanel_tot
= 756 Ib
Wwallexisting
= 13440 lb
Wbos
= 176 lb
Motel
= 21315 lb
Warray
= 9321b
7olncrease = (wtotal + Warray) / Wtotal = 22247 *100%-100% = 4.37% **
21315
**The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis
is required.
Limits of Scope of Work and Liability
We have based our structural capacity determination on applicable building codes, professional engineering inspection and design
experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel
installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and
procedures.
133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993
SCOPE OF WORK
GENERAL NOTES
LEGEND AND ABBREVIATIONS
TABLE OF CONTENTS
PAGE #
DESCRIPTION
• SYSTEM SIZE: 5220W DC, 5000W AC
•
ALL WORK SHALL COMPLY WITH NEC 2017, IBC, MUNICIPAL CODE, AND ALL
SOLAR MODULES
PV -1.0
COVER SHEET
• MODULES: (18) REC SOLAR: REC290TP2 BLK
MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS.
OSE
SERVICE ENTRANCE
• INVERTER(S):
•
PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017.
PV -2.0
SITE PLAN
(1) SOLAREDGE TECHNOLOGIES: SE5000H-US WITH
•
ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017.
PV -3.0
LAYOUT
REVENUE GRADE METERING
•
PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY
MP
MAIN PANEL
PV -4.0
ELECTRICAL
• RACKING:
GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35.
SNAPNRACK RL; FLASHTRACK COMP. SEE DETAIL
•
MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
SNR B MOUNT
SD -00708
•
INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SP
SUB -PANEL SNR A MOUNT
PV -5.0
SIGNAGE
• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
•
SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II
MODULES, ARE CLASS A FIRE RATED.
Q
PV LOAD CENTER ® CHIMNEY
• RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
•
CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
SM
SUNRUN METER ATTIC VENT
•
ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
V�
•
•
9.71 AMPS MODULE SHORT CIRCUIT CURRENT.
15.17 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a) & 690.8 (b)].
PM
n FLUSH ATTIC VENT
DEDICATED PV METER
'00�
Y.
� 1 iL
J PVC PIPE VENT
iCo�uHrr�r
INV
INVERTER(S) WITH ® METAL PIPE VENT
INTEGRATED DC
A�"S
APPROVED
DISCONNECT AND AFCI ® T -VENT
Reviewed for Code ComoNaM
AC
AC DISCONNECT(S)
SATELLITE DISH
�
Notes:
1)Verify or provide supplemental ground rod or
2017 NEC Art. 250.53(A)(2).
DC
DC DISCONNECT(S) FIRE SETBACKS
Mans Examinerpx•
Y_Y_dfi^*: rhe
rods per
2) Natural Gas piping to be bonded s per 2017 NEC
Art. 250.104(8).
=B
HARDSCAPE
COMBINER BOX E2
...��
Old carnpwor%a,s Shan nw he o atonic for, Oran awo ejef mviobro•to
3)Bond P/V panels to the building Grounding
-�
wsiom
fdw
resu rotogiveo wmytutvWWeaea ditPryasw,res.nawua
� mov � o� ro�`�g#WtWw0"V"°n`°/"" `'
Electrode System per 2017 NEC Art. 690(A).
INTERIOR EQUIPMENT —PL— PROPERTY LINE
rales a oche, adwnces of the city rheunot be wtid.
L
SHOWN AS DASHED SCALE: NTS
sunrun
A AMPERE
AC
ALTERNATING CURRENT
AFCI
AZIM
ARC FAULT CIRCUIT INTERRUPTER
AZIMUTH
VICINITY MAP
COMP COMPOSITION
DC
DIRECT CURRENT
EC #7080, ME #30603
_
Re
Y
(E)
EXT
EXISTING
EXTERIOR
6040 WEST 91 ST AVENUE, WESTMINSTER, CO 80031
PHONE 303.577.6527
Univ
FRM
FRAMING
FAX 303.577.9629
CUSTOMER RESIDENCE:
W52ndAve
INT INTERIOR
LBW
LOAD BEARING WALL
RANDAL J COWLING
WSMAve
MAG
MAGNETIC
3830 NEWLAND ST, WHEAT
MSP
MAIN SERVICE PANEL
RIDGE, CO, 80033
(N)
NEW
NTS
NOT TO SCALE
TEL. (303) 908-1690
W4GthAve
OC
ON CENTER
APN #: 24810
Lakeside
PRE -FAB PRE -FABRICATED
>*, anh Ag v BERKELEY
PSF
POUNDS PER SQUARE FOOT
PROJECT NUMBER:
501 R-83000WL
PV
PHOTOVOLTAIC
3830 Newland Street
TL
TRANSFORMERLESS
DESIGNER: (415) 580-6920 ex3
I2r
P
ICAL
V
OPTS
BRETT FINKELSTEIN
W 38th Avc W 38th Atte
W
WATTS
SHEET
REV
NAME
DATE
COMMENTS
Wheat Ridge W35tfiAve T
COVER SHEET
W 32nd Avg?
REV: A 6/10/201
ti.� 24th t.fL W a+?tr Ave
PAGE PV -1.0
ARRAY TRUE MAG PV AREA
SITE PLAN - SCALE = 3/32" = 1'-0" PITCH AZIM AZIM (SQFT)
® (E) GATE AR -01 22° 180° 171 ° 53.9
(N) ARRAY AR -03 AR -02 22° 90° 81° 215.7
AR -03 22° 270° 261- 53.9
(E) RESIDENCE FIRE SETBACKS FIRE SETBACKS
(T TYP) (18" TYP)
PL PL L PL PL PL PL
v
AC
� � r
Q
MP
SE PM � INV
co
�s
z
QJ r
sunrun
p D A
D. .a
o D p D D EC #7080, ME #30603
6040 WEST 91ST AVENUE, WESTMINSTER, CO 80031
yJ PHONE 303.577.6527
v FAX 303,577.9629
r
CUSTOMER RESIDENCE:
RANDAL J COWLING
3830 NEWLAND ST, WHEAT
RIDGE, CO, 80033
TEL. (303) 908-1690
PL PL PL PL p/- PL PL PL PL AP #: 24810
PROJECT NUMBER:
(E) FENCE 501 R-83000WL
N ARRAY AR -02 010%
( ) (415) 580-6920 ex3
(N) ARRAY AR -01 great'onp DESIGNER:
`V`S,00 BRETT FINKELSTEIN
SHEET
SITE PLAN
REV: A 6/10/2019
PAGE PV -2.0
DocuSign
Envelope ID: E969A5FC-8B18-4AD9-B64G7A3898ZZBEAU
ROOF
FRAME
FRAME
MAX FRAME
OC
ROOF EDGE
MAX PEN
MAX MoD.
DESIGN CRITERIA
ROOF TYPE
MOUNTING DETAIL
ROOF HEIGHT
EXPOSURE
MATERIAL
FRAME TYPE
SIZE
SPAN
SPACING
ZONE
SPACING
OVERHANG
MODULES:
AR -01
COMP SHINGLE
FLASHTRACK COMP. SEE DETAIL SD -00708
1 STORY
ATTIC
WOOD
RAFTER
2 X 6
13'- 0"
24"
3'
4' - 0"
2' - 0"
REC SOLAR: REC290TP2 BLK
AR -02
COMP SHINGLE
FLASHTRACK COMP. SEE DETAIL SD -00708
1 STORY
ATTIC
WOOD
RAFTER
2 X 6
11' - 9"
24"
3'
4'- 0"
2' - 0"
MODULE DIMS:
65.94" x 39.25" x 1.49" (38mm)
AR -03
COMP SHINGLE
FLASHTRACK COMP. SEE DETAIL SD -00708
1 STORY
ATTIC
WOOD
RAFTER
2 X 6
111-91,
24"
3'
4'- 0"
2' - 0"
MODULE CLAMPS:
Portrait: 8.2" - 16.4"
D1 - AR -01 - SCALE: 3/16" = 1'-0"
D2 - AR -02
PITCH: 22°
- SCALE: 1/8" = 1'-0"
Landscape: 0" - 9.75"
MAX DISTRIBUTED LOAD: 3 PSF
PITCH: 22°
AZIM: 180°
AZIM: 90°
SNOW LOAD: 30 PSF
WIND SPEED:
'-3"
105 MPH 3 -SEC GUST.
-2'-9"- -2'-9"-t-2'-9"- 2'-10"
-
LAG SCREWS:
��
5/16"x4.0": 2.5" MIN EMBEDMENT
2'
4„
NOTE:
-
16'-7"
- - 2"
'-9-
INSTALLERS TO VERIFY RAFTER
SIZE, SPACING AND SLOPED
3,
SPANS, AND NOTIFY E.O.R. OF
-
ANY DISCREPANCIES BEFORE
PROCEEDING.
10'
PENETRATION SPACING:
FULLY STAGGERED
ROW SPACING:
6-8
-� 4, TYP
1.00" BETWEEN ROWS
5'-4" I
COLUMN SPACING:
I 2'
—4' TYP-
0.75" BETWEEN COLUMNS
4-9
T
8'-4"
8'-5"
"
11-1
sunrun
EC #7080, ME #30603
D3 - AR -03 - SCALE: 3/16" = V-0"
PITCH: 22°
g
AZIM: 270°
—4'-3"—
- -
2'-5"
—3'-2"-
6040 WEST 91ST AVENUE, WESTMINSTER, CO 80031
PHONE 303.577.6527
303.577.9629
FAX 303.577.9629
CUSTOMER RESIDENCE:
2 a
3'-8"
V a o'
RANDAL J COWLING
c�
3830 NEWLAND ST, WHEAT
3c
RIDGE, CO, 80033
TEL. (303) 908-1690
1'-7 11
n
AP #: 24810
PROJECT NUMBER:
10'
501 R-83000WL
L/C
DESIGNER: (415) 580-6920 ex3
—4' TYP—
4�pt10
A 844
��Q
BRETT FINKELSTEIN
SHEET
4'-8" ��
I
t'' X934-9 ,t
gg
LAYOUT
V-5" I
t
DocuSigne°�
- ,.�.
6/10/2019
-
2'-5" - -
10"
T-8"
�
C ONA
/CiNA�ti
LPAGE
— 3'-2" —
V-3.0
P
SEE SITE PLAN FOR NORTH ARROW
18CA9954A5994 W.
CONDUIT SCHEDULE
120/240 VAC
CONDUIT
CONDUCTOR
NEUTRAL
GROUND
1
NONE
SINGLE PHASE
NONE
(1) 6 AWG BARE COPPER
2
3/4" EMT OR EQUIV.
(2) 10 AWG THHN/THWN-2
NONE
SERVICE
3
3/4" EMT OR EQUIV.
(2) 10 AWG THHN/THWN-2
(1) 10 AWG THHN/THWN-2
(1) 8 AWG THHN/THWN-2
METER #:
Notes:
EGC/GEC
4
3/4" EMT OR EQUIV.
(2) 6 AWG THHN/THWN-2
O
XCEL 000049403621
1)Verify or provide supplemental ground rod or
EGC/GEC
rods per 2017 NEC Art. 250.53(A)(2).
UTILITY
2) Natural Gas piping to be bonded s per 2017 NEC
GRID
Art. 250.104(6).
- SUPPLY SIDE TAP
3)Bond P/V panels to the building Grounding
,r'
Electrode System per 2017 NEC Art. 690(A).
4
1
EXISTING 125A
(N) LOCKABLE
SOLAREDGE TECHNOLOGIES:
C
MAIN BREAKER
BLADE TYPE
(N) LOCKABLE
SE5000H-US WITH REVENUE
FUSED AC (N) DEDICATED
BLADE TYPE
GRADE METERING
1
DISCONNECT
PV KWH METER
AC DISCONNECT
5000 WATT INVERTER JUNCTION BOX
PV MODULES
2 OR EQUIVALENT (1)
REC SOLAR: REC290TP2 BLK
.—
EXISTING
_
/
//
(18) MODULES
125A
o�.�.
M
O
ops -�
`�
�-•%
o
+
OPTIMIZERS WIRED IN:
—'
MAIN
_—
-
(1) SERIES OF (18) OPTIMIZERS
FACILITY
PANEL
30A FUSES
LOADS
_
FACILITY
GROUND
SQUARE D 240V METER SOCKET
SQUARE D
LOAD RATED DC DISCONNECT
D222NRB 200A CONTINUOUS
DU221 RB
WITH AFCI, RAPID SHUTDOWN
SOLAREDGE POWER OPTIMIZERS
3R, 60A WITH LEVER BYPASS
3R, 30A,2P
COMPLIANT
P320
120/240VAC [MAX 10' FROM
120/240VAC
UTILITY METERIMAX 10' FROM UTILITY METER]
CONDUIT SCHEDULE
#
CONDUIT
CONDUCTOR
NEUTRAL
GROUND
1
NONE
(2) 10 AWG PV WIRE
NONE
(1) 6 AWG BARE COPPER
2
3/4" EMT OR EQUIV.
(2) 10 AWG THHN/THWN-2
NONE
(1) 10 AWG THHN/THWN-2
3
3/4" EMT OR EQUIV.
(2) 10 AWG THHN/THWN-2
(1) 10 AWG THHN/THWN-2
(1) 8 AWG THHN/THWN-2
EGC/GEC
4
3/4" EMT OR EQUIV.
(2) 6 AWG THHN/THWN-2
(1) 6 AWG THHN/THWN-2
(1) 8 AWG THHN/THWN-2
EGC/GEC
MODULE CHARACTERISTICS
5220 W
P320 OPTIMIZER CHARACTERISTICS:
REC SOLAR: REC290TP2 BLK:
290 W
MIN INPUT VOLTAGE:
8 VDC
OPEN CIRCUIT VOLTAGE:
38.8 V
MAX INPUT VOLTAGE:
48 VDC
MAX POWER VOLTAGE:
32.1 V
MAX INPUT ISC:
11 ADC
SHORT CIRCUIT CURRENT:
9.71 A
MAX OUTPUT CURRENT:
15 ADC
SYSTEM CHARACTERISTICS - INVERTER 1
SYSTEM SIZE:
5220 W
SYSTEM OPEN CIRCUIT VOLTAGE:
18 V
SYSTEM OPERATING VOLTAGE:
380 V
MAX ALLOWABLE DC VOLTAGE:
480 V
SYSTEM OPERATING CURRENT:
13.74 A
SYSTEM SHORT CIRCUIT CURRENT:
15 A
NOTES TO INSTALLER:
1. 18 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE.
2. CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN
BREAKER IN MAIN PANEL ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED.
3. FIELD SPLICE WIRE TO APPROPRIATE SIZE FOR MANUFACTURE
TERMINATION SPECIFICATIONS WHEN NEEDED.
4. WIRE UPSIZE AT TIME OF INSTALLATION IS PERMISSABLE.
01 of
�reatR�d90
ON od"
t�a�t�9
WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION:
INVERTER(S), AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2017: 690.17(E), NEC
2014: 690.17(E), NEC 2011: 690.17(4)
&WARNING
DUAL POWER SUPPLY
SOURCES: UTILITY GRID
AND PV SOLAR ELECTRIC
SYSTEM
IWARNING J
ELECTRICAL SHOCK HAZARD
IF GROUND FAULT IS INDICATED
ALL NORMALLY GROUNDED
CONDUCTORS MAY BE
UNGROUNDED AND ENERGIZED
LABEL LOCATION:
INVERTER(S), ENPHASE ENVOY
ENCLOSURE (IF APPLICABLE).
PER CODE(S): NEC 2017:690.5(C), NEC
2014: 690.5(C), NEC 2011: 690.5(C)
ZEWARNING
PHOTOVOLTAIC SYSTEM
COMBINER PANEL
DO NOT ADD LOADS
I ARFI I n(ATInN-
3.5"
LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF
UTILITY SERVICE METER AND MAIN APPLICABLE).
SERVICE PANEL. PER CODE(S): NEC 2017: 705.12(B)(2)(3)(b),
PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b), NEC 2014: 705.12(13)(2)(3)(c), NEC 2011:
NEC 2014: 705.12(D)(3), NEC 2011: 705.12(D)(4)
705.12(D)(4)
&WARNING
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
C -Y
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
PER CODE(S): NEC 2017: 690.56(C)(1)(a)
LABEL LOCATION: LABEL LOCATION:
ADJACENT TO PV BREAKER (IF UTILITY SERVICE ENTRANCE/METER,
APPLICABLE). INVERTER/DC DISCONNECT IF REQUIRED BY
PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b), LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED
NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: BY LOCAL AHJ.
705.12(D)(7) PER CODE(S): NEC 2017: 690.12, NEC 2014: 690.12,
NEC 690.56, IFC 2012: 605.11.1
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2017:690.31 (G)(3), 690.31(G)(4),
NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011:
690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): NEC 2017: 690.54, NEC 2014: 690.54, NEC
2011: 690.54
INVERTER 1
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): NEC 2017: 690.53, NEC 2014: 690.53, NEC
2011: 690.53
NOTES AND SPECIFICATIONS:
• SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
• SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
• LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
• LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
• SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
• DO NOT COVER EXISTING MANUFACTURER LABELS.
CAUTION:
POWER TO THIS BUILDING IS
ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH
DISCONNECTS AS SHOWN
^' ^ R PANELS ON ROOF
NVERTER (EXT)
AC DISCONNECT
BREAKER DISCONNE
3830 NEWLAND ST, WHEAT RIDGE, CO, 80033
M
IN
SNAPNRACK RL FLASHTRACK COMP MOUNTING REVISION:
A 6/19/2017 NEW ITEM GTV
5/16" UMBRELLA LAG SCREW MUST EMBED 2-1/2" INTO THE
ROOF STRUCTURAL MEMBER/RAFTER _
5/16" UMBRELLA LAG SCREW FLASHTRACK COMP
UMBRELLA GASKET
5/16" STAINLESS STEEL (SHADED GRAY)
UMBRELLA LAG SCREW A
2-1/2" MINIMUM EMBEDMENT\
� o
ROOFING
FLASHTRACK COMP
COMP FLASHING
(HATCHED)
)OF SHEATHING
COMPLETED INSTALLATION
DETAIL A SECTION VIEW
COMP FLASHING
SLIP FLASHING UNDER
SHINGLE ABOVE
ROOFING
MATERIAL
ROOF RAFTER (TYP.)
ROOF ATTACHMENTS SHALL ROOF SHEATHING, UNDERLAYMENT,
ALWAYS BE EMBEDDED INTO
ROOF RAFTERS OR OTHER AND ROOFING MATERIAL (TYP.)
STRUCTURAL MEMBERS
FLASHING SHOULD EXTEND
TO END OF SHINGLE COURSE
FLASHTRACK COMP
FLASH TRACK SHOULD BE ORIENTED NO MORE
THAN 3 DEGREES FROM PARALLEL TO RAFTER
n P1/ICTKIP` AAATCnTAI
ROOF DECKING
2-1/2" MIN. EMBEDMENT ow of
INTO STRUCTURAL MEMBER
Wheat Ricige
ng nivis,On
COMPLETED INSTALLATION
,Sn(a n ra�n Sunrun South LLC DESIGNER: G.MCPheeters SCALE: NTS
\\��J� PART NUMBER: DESCRIPTION: REV
l�I] 595 MARKET STREET, 29TH FLOOR • SAN FRANCISCO, CA 94105 USA
PHONE (415) 5BM900• FAX (415) 5SM902 DRAFTER: G.Viscuso SD -00708 PENETRATION DETAIL, FLASHTRACK COMP
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY DATE: 6/19/2017
REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE APPROVED BY: G.McPheeters
WRITTEN CONSENT OF SUNRUN SOUTH LLC.
City of Wheat Ridge
E -Res. Furnace Replacement PERMIT - 201900373
PERMIT NO: 201900373 ISSUED: 03/06/2019
JOB ADDRESS: 3830 Newland St EXPIRES: 03/05/2020
JOB DESCRIPTION: Replacement of 70K BTUs,90 percent efficient gas furnace and AC unit 2.5
tons, 16 SEER. Electrical for AC reconnect.
*** CONTACTS ***
OWNER (303)908-1690 COWLING MICHELLE R
SUB (303)466-4209 Rosalie Cooper
SUB (303)466-4209 Rosalie Cooper
018111 Cooper Heating & Cooling
018111 Cooper Heating & Cooling
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA I Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,272.00
FEES
Total Valuation 0.00
Use Tax 173.71
Permit Fee 188.45
** TOTAL ** 362.16
*** COMMENTS ***
*** CONDITIONS ***
Both the front and back of this permit are required to be posted on the job site at all
times. If the complete permit is not present, inspections WILL NOT be performed.
Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required
to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every
level of the structure.
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION
City of Wheat Ridge
E -Res. Furnace Replacement PERMIT - 201900373
201900373
3830 Newland St
Replacement of
tons, 16 SEER.
ISSUED: 03/06/2019
EXPIRES: 03/05/2020
70K BTUs,90 percent efficient gas furnace and AC unit 2.5
Electrical for AC reconnect.
f, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am t e legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this ermrt. I further attest that I am legally authorized to include al[ entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
�. This permit shall expire 365 days after the date of issuance regardless of activity. Re uests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
1. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
�. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicable„code or any ord�� nce or regulation of this jurisdiction. Approval of work is subject to field inspection.
>ignature of Chief Building Official Date
MQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Lagenia Reimer /6o
From: no -reply@ ci.wheatridge.co.us
Sent: Wednesday, March 6, 2019 11:54 AM
To: CommDev Permits
Subject: Online Form Submittal: Residential Furnace/Boiler Replacement Permit Application
Categories: Gina
Residential Furnace/Boiler Replacement Permit Application
This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or
BOILER - LIKE FOR LIKE ONLY.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN
ORDER FOR THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
replacement residential
furnace or boiler like for
like?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
Property Owner Email
Address
Attach Credit Card
Authorization Form -
**DO NOT ATTACHED
RANDOM FORMS**
3830 Newland St.
Randal Cowling
303-908-1690
rcklaatu@yahoo.com
newland st. cc authorization. pdf
CONTRACTOR INFORMATION
Contractor Business Cooper Heating and Cooling _
Name i, 2. )
Contractor's License 018111
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone 720-361-4245
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Email Address kdaniels@coopergreenteam.com
Retype Contractor Email
Address
DESCRIPTION OF WORK
kdaniels@coopergreenteam.com
What type of unit is being Furnace
installed?
Number of BTUs
What is the efficiency
(%) of the unit?
Is the unit GAS or
ELECTRIC?
Where is the furnace or
boiler located (for
example, basement,
crawlspace, etc)?
70000
96
gas
crawl space
Project Value (contract 5515
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
2
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Person Applying for Kathi Daniels
Permit
Email not displaying correctly? View it in your browser.
La enia Reimer ZO 19 00 573
From: no-reply@ci.wheatridge.co.us
Sent: Wednesday, March 6, 2019 11:51 AM
To: CommDev Permits
Subject: Online Form Submittal: Residential Replacement Air Conditioner/Evaporative Cooler
Permit Application
Categories: Gina
Residential Replacement Air Conditioner/Evaporative Cooler Permit
Application
This application is exclusively for RESIDENTIAL REPLACEMENT AIR
CONDITIONER OR EVAPORATIVE COOLER - LIKE FOR LIKE ONLY.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN
ORDER FOR THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential replacement
AC or Evaporative Cooler
like for like?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
Property Owner Email
Address
Attach Credit Card
Authorization Form -
**DO NOT ATTACH
RANDOM
DOCUMENTS**
3830 Newland St.
Randal Cowling
303-908-1690
rcklaatu@yahoo.com
newland st. cc authorization. pdf
CONTRACTOR INFORMATION
1
Contractor Business Cooper Heating
Name
Contractor's License
018111
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone
720-361-4245
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Email Address
kdaniels@coopergreenteam.com
Retype Contractor Email
kdaniels@coopergreenteam.com
Address
DESCRIPTION OF WORK
What type of replacement
Replacement Air Conditioner
unit are you installing?
How many tons is the
2.5
unit?
For AC - what is the 16
SEER?
For Evaporative Coolers,
what is the CFMs?
Where is the unit located crawl space
(for example, rooftop,
backyard on ground etc)?
Is electrical needed for re- Yes
hook?
If electrical work is being 018111 ac reconnect
performed, you must
provide electrical
contractor's Wheat Ridge
license no. and scope of
work.
Project Value (contract 2757
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
2
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Person Applying for Kathi Daniels
Permit
Email not displaying correctly? View it in Vour browser.
a r , City of Wheat Ridge
Residential Roofing PERMIT - 201707628
PERMIT NO: 201707628 ISSUED: 09/25/2017
JOB ADDRESS: 3830 Newland ST EXPIRES: 09/25/2018
JOB DESCRIPTION: Residential Re -roof to install OC asphalt shingles - 16 sq Pitch = 4/12
*** CONTACTS ***
OWNER (303)908-1690 COWLING MICHELLE R
SUB (303)984-7663 Judy Antener 070171 1-DERFUL ROOF & RESTORATION
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,000.00
FEES
Total Valuation 0.00
Use Tax 168.00
Permit Fee 172.60
** TOTAL ** 340.60
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name)
roof covering" is required to be on site at the time of final inspection.
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped
off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the
Homeowner.
City of Wheat Ridge
Residential Roofing PERMIT - 201707628
PERMIT NO: 201707628 ISSUED: 09/25/2017
JOB ADDRESS: 3830 Newland ST EXPIRES: 09/25/2018
JOB DESCRIPTION: Residential Re -roof to install OC asphalt shingles - 16 sq Pitch = 4/12
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications=
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be
perfo ed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
i ature of OWNER or CONTRACTOR (Circle one) Date
This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official andmay be subject to a fee equal to one-half of the original pennit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Budding Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services DIvision in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicab6:2�
r any ordina
nce or regulation of this jurisdiction. Approval of work is subject to field inspection.
�J�J1ls
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dane Lovett
2b 1707 ( Z,
contractors only. This type of permit is ONLY being processed online --do not come
From:
no-reply@ci.wheatridge.co.us��
Sent:
Wednesday, September 20, 2017 11:08 AM
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
To:
CommDev Permits
Subject:
Online Form Submittal: Residential Roofing Permit Application
your contractor's license or insurance has expired, and you may update those
Follow Up Flag:
Follow up
Flag Status:
Completed
C
C
Residential Roofing Permit Application
fi
c �
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
JL
Property Address 3830 Newland St
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
Michelle & Randal Crowling
303-908-1690
41
Property Owner Email
Address
Do you have a signed
contract to reroof this
property?
Applications cannot be
submitted without an
executed contract
attached below.
Attach Copy of Executed
Contract
1 derfulcolleen@gmail.com
Yes
17-0278 Crowling2f
CONTRACTOR INFORMATION
Contractor Business 1-derful Roofing & Restoration
Name
L
Contractor's License 070171
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Address
(Primary address of your
business)
303-984-7663
9858 W Girton Dr
Contractor Email Address 1derfulcolleen@gmail.com
Retype Contractor Email 1 derfulcolleen@gmail.com
Address
DESCRIPTION OF WORK
TOTAL SQUARES of 16
the entire scope of work:
Project Value (contract 8000.00 ,
value or cost of ALL
materials and labor)
Are you re -decking the
roof?
Is the permit for a flat
roof, pitched roof, or
No
Pitched roof (2:12 pitch or greater)
42
both? (check all that
apply)
What is the specific pitch
of the PITCHED roof?
How many squares are
part of the PITCHED
roof?
Describe the roofing
materials for the
PITCHED roof:
Type of material for the
PITCHED roof:
Provide any additional
detail here on the
description of work. (Is
this for a house or
garage? Etc)
4:12
16
OC TruDefinition Duration Storm
Asphalt
Re -Roof House 15 sqs and Shed 1 sq
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
43
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Name of Applicant Colleen Jacobsen
Email not displaying correctly? View it in your browser.
44
9858 W. Girton Drive
Lakewood, CO 80227
Phone: 303-984-ROOF(7663)
Fax: 855-696-7776
I DERFUL
RQDFING S RESTORATION
PROPOSAL Fr,:
}j
Name:r Q o,,—A,-,)
Job Address s
City, State, Zip:
Phone: `� ^�r—ge,,.�
Mailing Address:
(if Different)
Email Address:
Best way to contact: _
--I'fear Off
and eaves are open or cl sed.
Ins ect Deckin : Dote ted existing decking
replaced at cost of $ Per Sq. ner
w II be notified if any damaged wood is found during tear off.
Install ice shield on eaves and in valley(s) 14-J' c� -
r�Install drip edge 2jo Color
Ia tall undedayment VVz-,, )CU-�
Recover roof with
year manufacturer warranty.
�'9hingle manufacturer
color
J-fiNail every shingle
install eS ridge style
,-}-iTistall pipe jacks -4-155-d jacks swamp cooler
-= 3- �p'flash sidewalls hep flash chimney step flash skylight
Derful Roofing & Restoration will provide general liability insurance
of at least $2,000,000 and Workers Compensation of at least $500,000
�an up and haul of roofing debris--'I:-;lean out gutters
,,W-agnetic sweep of surrounding area lean around landscaping
,% All required Permits furnished by 1-Derful Roofing & Restoration -
to be reimbursed by Insurance Company
-Derful Roofing & Restoratipn five year warranty on labor
Current Ventilation Recommended -----'
C
Decline recommendation on ventilation
.w.1J `' 1 1
Proposal Date: 6 - D -J % 7
This proposal may be withdrawn by 1-Derful
Roofing & Restoration if not accepted within 30
days from the above date.
SUBMITTED BY: 1-D ,,RF,!UL ROOFING RATION
1-Derful Rep: LP -t-
Cell Phone: "- 7- 7 �3
Insurance Company:'_
Adjustor Information: �-
Policy Number:
Claim Number: t+ �' . aC3 '7 Coe, v ;I i f-{
Z gutters:
color Y-^ Outlet
❑ Siding:
D Extra work
Special instructions:
1-derful Roofing and Restoration shall hold in trust any
payment received from you until 1-derful has delivered
roofing materials at the site or has performed a
majority of the roofing work on your property.
$ 1000,0"" deductible to be collected
at time of material delivery.
$ 1Z T.D IV,S initial totalclaimamount
as of ,% 3 z� /20This
price is subject to supplements/adjustments.
Roof work to be completed within 21 days of final
insurance approval and mortgage endorsement*
Date of ept ce
f /
1-Derful R In & R ora�tionnRRRepresentative Homeowner's ignature
Prope O er is/is not intending to make payment from the proceeds of a property and casualty insurance policy.
INSURANCE ALLOWANCE AGREEMENT If so, homeowner must read and sign below.
IlWe agree to retain 1-Derful Roofing & Restoration (contractor) to repairfreplace the damaged or entire portion of the property described on this contract contingent upon the contractor obtaining my insurance
company's approval and payment to have said work completed. It is agreed that the contractor is empowered to contact my insurance carrier and to meet with their representative in order to negotiate the amount
of damage, the cost of the repair or replacement of the damage to the above property. Upon the insurance carrier agreement with the contractor and the dorm payment being made the work will be scheduled
and may begin on a first in first out basis.
Checks shall be made payable to 1-Derful Roofing & Restoration.
In the event that the insurance carrier fails to negotiate in a fair and reasonable marner, the contractor shall not be held liable and this agreement will be void_ The contractor will release the complete file to the
Commissioner of Insurance at the customer's request.
Insured out of pocket expense will not exceed the insured (purchaser) policy deductible for the work agreed upon between the insurance carrier and the contractor. Insured also agrees to provide all the necessary
documentation for the claim (including documentation to facilitate payment from insurance carrier andior mortgage holder). The contractor reserves the right to file for supplemental claims due to material and/or
labor increases due to a storm environment or to insurance adjuster's mistakes, errors or omissions.
Insurance
1/we agree by signing above to all the contract conditions on both the front and back of this agreement
a
i CITY OF WHEAT" RIDGE
_:�9�Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number:
❑ No one available for inspectin%..Time AM/PM
Re -Inspection required: Yes/' No)
When corrections have been made, call for re-insp9ctbn at 303-234-5933
Date:C ! �' = a % Inspector:
DO NOT REMOVE T NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
�!D
Job Address:
Permit Number: u/ o I ( �'
❑ No one available for inspection;,Time U AMS
Re -Inspection required: Yes No
When corrections W/ _/
been made, call for re -inspection at 303-234-593
I3
Date: v( ��l/ Inspector: �%k
DO NOT REMOVE THIS NOTICE
e i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: R 0
Job Address: 3 %3® k)x- w VA Py S7 -
Permit
T"Permit Number: D.0/1 Oy 0 q/
ff o v -P D
STa,— v s e�rqn h lc
❑ No one available for inspection: Time/U: Z Q AM/PM
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303-234-5933
t
Date: �'%v� l ? Inspector:
DO NOT REMOVE THIS NOTICE
4' CITY OF WHEAT RIDGE
Building Inspection Division
31 (303) 234-5933 Inspection line
?;r,(303) 235-2855 Office (303) 237-8929 Fax 4.
INSPECTION NOTICE
Inspection Type: tf`
Job Address: `
Permit Number:iixi l
f�
a." '
a
❑ No one available for inspection: Time 3 AMM
Re-Inspection required: Yes No
When corrections have been made, call for re-inspection at 303-234-5933
3
Date: Inspector:
DO NOT REMOVE THIS NOTICE
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING INSPECTION LINE - (303-234-5933)
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80033 - (303-235-2855)
Building Permit Number
Date
16886
4/8/2004
Property Owner: MARCELLA DOZIER / MICHELLE & RANDY
COWLING
Property Address: 3830 NEWLAND ST
Contractor License No. :
Company:
Phone : 424-6486
Phone:
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and
do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or reslrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Buildin9
Code (U.B.C.) and all other applirab*W heat Fj1fVgAordinaAces, for work under this pprjnit. i
(OW NER)(CONTRACTOR)
Construction Value :
$360.00
Permit Fee :
$30.55
Plan Review Fee :
$0.00
Use Tax :
$7.20
Total:
$37.75
Use:
Description : PRIVACY FENCE
47' LONG NORTH SIDE OF BACKYARD. MATERIALS: CEDAR
BUILDING DEPARTMENT USE ONLY
SIC : Sq. Ft. :
Approval : JH
Zoning : R-3
Approval :
415/04
Roof
Piease Notz:
Owner/contrac[or is responsihic ror I-~^~'~~ ~rcpcr~:
lines and constructing impro:,c c!; ,
approvcd plao aud er,- r_.!
The City is r.ot resp n;, _c : 1c
subc;it.ed ivit! m h , _.ci ; i, . ,
ecors resulting Gn!n in.r. .__...:.~r,
Approval:
Occupancy: Walls
Electrical License No :
Company:
Expiration Date :
Approval:
Plumbing License No :
Company:
Expiration Date :
Approval:
Mechanical License No :
Company :
Expiration Date :
Approval :
(1) This permit was issued in accordance with the provisions set forth in yopur application and is subject lo the laws of the State of Colorado and to the Zoning
Regulations and Building Code of W heat Ridge, Colorado or any other applicable ordinances of the City.
(2) This permit shall expire if (A) the work aulhonzed is not commencetl within sixry (60) days fmm issue date or (B) ihe builtling authorized is suspended or
abandoned for a period of 120 days.
(3) If this permit expires, a new permit may be acquired for a fee of one-halt the amounl normally required, provided no changes have been or will be matle in the
onginal plans and speciflcations and any suspension or abandonment has not exceedad one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, /ull fees shall be paid for a new permit.
(4) No work of any manner shall be tlone that will change the natural Flow of water causing a drainage problem.
(5) Conlractor shall noti/y the Building Inspedor twenly-(our (24) hours in atlvance for all inspedions and shall receive written approval on inspection card before
procaediing with successive phases of the job.
(6) The issuance rmit or ihe a proval of tlrewings and specifcations shall not be constmetl to be a permit for, nor an approval of, any violation of ihe
.LiLpe
provi ' uildi s or an r ordinance, law, rule or regulation.
Stories : Residential Units :
Chief Building Inspector
Please sign Terms and Conditions on reverse side of page
o` wNE4r COMMUNITY DEVELOPMENT DEPARTMENT Building Pernvt Number:
^ a BUILDING INSPECTION LI1VE - 303-234-5933 Date:
CITY OF WHEAT RIDGE
Y'
7500 WEST 29TH AVENUE
CD~Oqp~ WHEAT RIDGE, CO 80033 -(303-235-2855) `Ul ~~~~ICATION
Property Owner:MARC£IIR At7JEq Mlf,~-°lIE Gawiinrlj~lso~ (~uli'rl
Property Address: 3a30 Q&A qop '*T Phone : 3o; q2'( 6((8 6
Conaac[or License No.:
Company: Phone:
OX\TER/CONTRACTOR SIGNATURE OF GNDERSTMDINC AND ACREEMENT
1 hereby cmify that the sctback distances propostd by this permi[ application are accurztc,
and do not violate applicable ordinances, rula or rcgulations of the Ciry of Wheat Ridgc or
covenanls, easemrncs or rcstrictions ofrecord; thal all measurements shown, and allcgalions
madc arc accurzte; that I havc rcad and agrce to abide by all conditions yrinud on this
appliwtion and that 1 assume full rcsponsibiliry for compliancc with thc Whcat Ridge
Building Code (U.B.C) and all other applicable Whea1 Ridge Ordinances, (or work undw
this pertnit.
IO~gCOMRACTOR):SIGNfD l DATE 2
/
(OwNERxCOM'RACfOR): PFUMED DAiE
DESCRIPTION:
Construction Value`$
Permit Fee:$
Plan Review Fee:$
Use Tax:$
TOtfll:$
_PRIUA&q (Euc.E ql' Co;A NoM Sjpf oF BPCY--4Aa
T4aTEeiai-5 : cE,Qlp,a
BUILDING DEPARTMENT USE ONLY
ZONIN6 COMMEN7E:
Approval: J~ J/s I 0¢
Zoning: K_3
BUILDIN6 COMMENTS:
Approval:
PUsuc WoaKS CorMerRS:
Approval:
SIC: Sq.Ft.:
Occupancy: Walls: Roof: Stories: Residential Uniu:
Elecaical License No: Plumbing Licerae No: Mechanical License No:
Company: CompanY: Company:
Expiration Date: Expiration Date: Expuation Date:
Approval: Approval: Approval:
(I) This permit wu iuued in acmrdance w ith the pmvisions se1 forth in yaur appliuuon md is subjxt m N< laws of the $nle of Cobndo and to the Zoning
Regulations and Building Coda of WL<at Ridge, Cobndo wmy otha applkabk ordinancn of ae Ciry.
This pemin shall enpirt if(A) the work authorizcd is `wt commenccd rithin sinry (60) days hom iuue dau or (B) the building authorized is susyendcd or
abaiMoned frn a period of 120 daya.
(3) If Nis permit expires, a neu pemiii may be uquired fw a ke of one-half the amoum nwmally required, pro.ided no clungcs have been or wIO be made
m the origind p4ns and specifications uW anY suspcnsion wabandonment has nd exceedd one ( i) yeu. If changes have pttn or if susyatsioa or
abandonmrnt exceeds om (1) year, full fees shall be pud tw a ncw peMiL
(4) I:o work of any manner WII be don< Ow1 will change ihe nuunl flow of waur nusin8+ dmiMBe 7mbkm.
(5) Contru Wr shall norify the BuiWinQ inryecmr iwrnry-four (21) Iwurs in advance for a11 insy«oons and shell receire wrinen appruval on insyecUOn nid
beforc proceediny with successive phaus of th<job.
(6) T he iuuance of a pertmt ar the approval of dnwings uM specificauons yhall .wt bt conswed a bc a permit f«, nor u appmval of, any no6non of Jw
pro,isions of the building codn or any otAer ordinantt, law, ruk or regu6don.
Chief Building Inspector
3?30 303 efv4 6-18C,
PERMIT:
ADDRESS:
JOB CODE:
INSPECTION RECORD
Inspection online form: http://www.ci.wheatridge.co.us/inspection
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site
Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business
Foundation Inspections
Date
Inspector
Initials
Comments
102 Caissons / Piers
103 Footing / P.E. Letter
104 Foundation Setback Cert.
105 Stem Walls
106 Foundation wall Insulation
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground / Slab Inspections
Date
Inspector
Initials
Comments
201 Electrical / Cable/ Conduit
202 Sewer Underground Int.
203 Sewer Underground Ext.
204 Plumbing Underground Int.
205 Plumbing Underground Ext.
206 Water Underground
vo rroi %.over unaergrouna or tseiow i in-sian work Prior To Approval Of The Above Inspections
Rough Inspection
Date
Inspector
Initials
Comments
301 Rough Framing
302 Wall Sheathing
303 Roof Sheathing
304 Sheer Inspection
305 Insulation
306 Mid -Roof
307 Metal / Lath / Stucco
308 Rough Electrical Residential
309 Rough Electrical Commercial
310 Electrical Meter Residential
311 Electrical Meter Commercial
312 Temp. Const. Meter
313 Rough Plumbing Residential
314 Rough Plumbing Commercial
315 Shower Pan
SEE OVER FOR ADDITIONAL INSPECTIONS
/-:� %(02 �r
71
Rough Inspection (continued)
Date
Inspector
Initials
Comments
316 Rough Mechanical Residential
317 Rough Mechanical Commercial
318 Boiler / Furnace
319 Hot water tank
320 Drywall screw and Nail
321 Moisture board / shower walls
322 Rough Grading
323 Miscellaneous
•�
Z'�1
Final Inspections
Date
Inspector
Initials
Comments
402 Gas Meter Release
403 Final Electrical Residential
404 Final Electrical Commercial
405 Final Mechanical Residential
406 Final Mechanical Commercial
407 Final Plumbing Residential
408 Final Plumbing Commercial
409 Final Roof'-
•�
Z'�1
410 Final Window/Door
411 Landscape/Park/Planning
Inspections from these entities shall be requested
one week in advance.
For landscaping and parking inspections please
call 303-235-2846
For ROW and drainage inspections please call
303-235-2861
For fire inspections please contact the Fire
Protection District for your project.
412 Row/Drainage/Public Works
413 Flood plain Inspection
414 Fire Insp. / Fire Protection
415 Public Works Final
416 Storm Water Mgmt.
417 Zoning Final Inspection
418 Building Final Inspection
Note: All items must be completed and approved by Planning, Public Works, Fire and Building
before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not
constitute authorization of occupancy.
For Low Voltage permits please be sure that rough inspections are completed by the Fire District and
Electrical low voltage by the Building Division.