Loading...
HomeMy WebLinkAbout4949 Marshall StreetCity of Wheat Ridge Commercial Roofing PERMIT - 201802147 PERMIT NO: 201802147 ISSUED: 08/01/2018 JOB ADDRESS: 4949 Marshall St EXPIRES: 08/01/2019 JOB DESCRIPTION: Commercial re -roof -Tear off existing R -panel metal roof and install new R -panel metal. Squares: 75 Pitch: 2/12 **REVISION: Remove and replace skylights which was already included in valuation.** *** CONTACTS *** OWNER (303)422-3647 ADDYX ENTERPRISES LLC SUB (720)724-0081 Steve Greenly 150196 Adamstree Roofing & Construc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 420 / Storage Warehouse; 0 BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 67,500.00 FEES Total Valuation 0.00 Use Tax 1,417.50 Permit Fee 874.45 ** TOTAL ** 2,291.95 *** COMMENTS *** *** CONDITIONS *** In order to pass a final inspection on commercial elastomeric or similar type roofing, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and Mid -roof inspections may be called in at the same time, 100 percent of the sheathing must be complete and 25-75 percent of the midroof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. City of Wheat Ridge #' Commercial Roofing PERMIT - 201802147 PERMIT NO: 201802147 ISSUED: 08/01/2018 JOB ADDRESS: 4949 Marshall St EXPIRES: 08/01/2019 JOB DESCRIPTION: Commercial re -roof -Tear off existing R -panel metal roof and install new R -panel metal. Squares: 75 Pitch: 2/12 **REVISION: Remove and replace skylights which was already included in valuation.** I, by m�si'nature, do hereby attestthattheworktobe performed shapplicaleuidingcoesand all apicable municipacodes, policbyhe lgal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying Flans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official andmay be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Off pial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The i ce or granti f a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any I eco or any . dinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of h6a-tf cm _ "jge uNiTy DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perrnjts@ci.wheatridqe,co.us I FOR OFFICE USE ONLY I PlanlPerm it # JC,, / ill ") / 1—/4 'll eA- Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. `" Property Address: Property Owner X, Cr\"T-iS-e_0 Property Owner Email: CAN kA@G s` -f, La sit Mailing Address: (if different than property address) Address: �'�-- c City, State, Zip: Arghitect/Engineer., Architect/Engineer E-mail: Phone: Contractor: 19-0053 Phone: 3()*3-- zld,- 3-3401-17L Contractors City License 1511 Phone: 3(33-- q3,9-- 3a39 Contractor E-mail Address. Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # ., . P J. " ., . p. • A " , , , ,, I ,, piIIIII, I I., � nIll .111 I'll Jill, [ Iq ii 11111 ARI Ali 11,11111'W 10101. , I I pry 1 [11110 111 oil III Ill Mi I I I 1 Other City Licensed Sub, City License # Mechanical. - WR City License # Complete all information on BOTH sides of this form I -A P COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE COMMERCIAL ROOFING COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc,) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT OTHER(Describe) _ (For ALL projects. please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Ch eA 4-c Sq. FVILF 7 ,/-23 7 Btu's Amps Gallons Squares Zr Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ (07161:'�V, 06 1 OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City ot"Wheat Ridge or covenants, easements or restrictions of'record: that all measurements shown and allegations made are accurate. that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work Under any pennit issued based on this application: that I an) the legal owner or hake been authorized by the legal owner of the property if.) perform the described %vork and am also authori7ed by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE., (Off"AL,R)((CON'TR,4CI'ORJItr (,4t.ITIIORIZt"`DREPRESE-,VTATII,'L,) )f (014rAll-R) (COAYRACTOR) rj",NT NAME - ZONING COMWENTS Reviewer BUILDING DEPARTMENT COMMENTS - Reviewer PUBLIC WORKS COMMENTS Reviewer SIGMA DEPARTMENT 11 1W,x„rA qy- 4-1 P ;41.1.rjt 11 1 �1, PROOF OF SUBMISSION FORMS Fire Department [I Received [I Not Required 'Water District 0 Received ❑ Not Required Sanitation District n Received ❑ Not Required R DATE: OCCUPANCY CLASSIFICATION, TYPE OF CON&TRUCTiON SPRINKLE -RED OCCUPANT LOAD Building Division Valuation: $ i CITY OF WHEAT RIDGE Building 1 ltpection Divivan (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 4-1 c Job Address: _41 9 y 9 al ass Permit Number: 'dG i $ a l y 7 n a) A>� r -o V e d ❑ No one available for inspection: Time 43'= S- Oopm RelInspection required: Yes o When corrections have been made, call for re -inspection at 303-234-5933 Date: 9A La Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L) 0 C1 - I—i' n e• f Job Address: y 9 149 /11 a r s' a I 1 s4 Permit Number: G 1 F5 0 e-1 7 ?- ! fl ce ) UVB n 7 (]C\{ten v P /! ❑ No one available for inspection: Time =) &PM Re -Inspection required: (9)No When corrections ave been made, call for re -inspection at 303-234-5933 Date: "?31 ) 6 Inspector: �l i__� DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Sf_� l Job Address:`�� 1 `i ci 10 a v C_� k-ex.OU Permit Number:Z�- ❑ No one available for inspection: Time 1 �' 3� AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: j --?_'4 — 14- Inspector: -" DO NOT REMOVE THIS NOTICE O 10 ° [a n rr m m wrr P. Cr rh n ~ Hs N O 0Om CJ r J G O H n ° m m m ° M O 0 1 N- (D ri m � a O H O m m Baa m W G p £ � O 0 m H m c n r°h rr � O to m � M V 0 G N C3a ro r- G W FC £ N- rr O G rr n O r n a ro H p m x a �Y• m m rrr n CD 0 n 0 rt ro M m n n c a rt IN m a " m E o m m G ro r• M ro M 0 Y• rt Om x ro M m i rt a Y' rt n m O 'o„ n m Y• tr' E d• G mm r - m a r n a a a 0 w N E O 0 m 0 m p o r+ CL m m s a0 rt .< g w t % m Y w 0 v- O G rt n ro Y- rt w m M G °n cr m rt m ro m o" G W O m am m a m 10 m C rOn P - rt Y m m a b• 0 Y• O N a a m o a a Q o n � ro a m 0 5 r+Y• ?m m m n m n m G H ; a m m m m n CL rt fL� a a m O m 0 m m to b b I"j C N F- Frt r t b o N o O 0 O Q � dl y O v a 7 y U d w rt (D O F' N N O H J E x _ E Ln z O * d O c7 m�mn Ota H rn i W W � ' � p� lV O O N d w rt (D O F' N N O H J 1=yq e !CITY OF WHEAT RIDGE j Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: i Job Address: Permit Number: VV Erl ti ❑ No one available for inspection: Time M/pM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division�'� (303) 234-5933 Inspection line �45e (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: C f (i I3 r' f f Pr f /U Job Address: `'(C1W1 M,+�?S'wntC- Permit Nube i► Lo o i 6 e� { c17,4,1; rtI (ec,1.S = S10c..-"Ie C ✓40 -f � to 'en4-a1 lcl4(�r 0"fer : n(_ t ,,, Cf 1. Al --9n -a -j e ❑ No one available for inspection: Time A ` 7 M/ M Re -Inspection required: oesNo *When corrections have been made, call for re -inspection at 303-234-5933 f-71-17 C . Date: Inspector: ���"'� DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE - Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax o I INSPECTION NOTICE Inspection Type: t -f t, S Job Address: tI g get 1"4-A9tt i -L G Sr Number: 20l 4 0 ? (Permit ✓L•'i�C': ACL` 4rv'`�"�7, ^ jr� . C �j /1 k` 5, cr�e�n )1 . c o S r f en / nc'., �u }-e Ul C(\ � o"... ' !? /'. "t• ti {-F`� �-Lt C+ at � � r s./ ✓, 1 1 4!I c�{ IaGyC EcFe� rc�e l.v/.+1c- vlo�' f u/rrc� Prr7 , / I f(� / C�oIC�P .`110J.�i/ (rot -P2 1 'rrIIP lltjI/!C— i {OD�p iCir� �l/ur:�r�-.P�.,� .`Ct� 1-fir`/1.F.C�� �•G'.7ct !'('JC-'✓ Or'.F�n�z;l �r:� Tart rL4 OLS #sr-�+�� >re.:c )fin,• '. r�CSbIfPS� t 11 c;raJ!fun-4 ('UJ / "r 7 1 c :r i�:Srr, �. OC I 17 J �e 0 /• rov e 0 c'7F r Ps�ti ✓�(t ja �?-i �a fal,iP .'1i°hf-P✓vle jn Z. ElL/ one available for inspection: Time �% 2�G AM/PM Re -Inspection required: es No *When corrections have been made, call for re -inspection at 303-234-5933 r; Date: Inspector: DO NOT REMOVE THIS NOTICE Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLYaA_j Date: (�}_� �� I Planmennit # Plan Review Fee: Building Permit, Application . ' Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed.' Property Address: 4$1'tq p\A-0_S kAtL Srg (f2l DIi oo 33 Property Owner (please print): Phone: 313 3 Property Owner Email: AhT-1+64 !I (I?- S ct oft e 4,% S g I Mailing Address: (if different than property address) Address: City, State, Zip: Arch itectlEng! neer: S -r fe/u& ij ' -1 4"'te - - P_"" - ArchitectlEngineer E-mail: _("Sk 0 (-%C& I( r- —Phone: 5-2-2. L-2 & -7 . Ce 44 Contractor: 9VI 6K Lt- C -V .1 S-TxAre'-D 5_6)Lo-z'e� XbV-'VL-t4 Contractors City License #: Co & M &J Contractor E-mail Address*I - Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: CityLicenseb. Plumbing: W.R. City License # iq i% '�l C Phone: 03'1s§ 9'79l Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT �] COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) LJ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT THER (Describe) 5ftln PgPt,4-6C-4i6-)11J— (For ALL projects, please provide a,detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. FULF Btu's Gallons Amps Squares Other Wall Siqn Calculation Sheet You must complete this sheet and include it in the submittal package for any new wall signs. You will also need to create a site plan and a detail sheet of the signage. Project Address: 7-. Contractor: Ttji 'qac,c, c,t You are allowed 1 square foot of signage for every 1 linear foot of wall to which you are attaching a sign. All wall signs must be adjacent to a street or major interior drive. Step 1: Measure the length of the wall(s) where you are attaching the sign: Wall 1 - _ feet Wall 2 - feet Wall 3 - Step 2: The length of the wall is the allowable square footage for the wall sign Wall 1 allowable signage - Wall 2 allowable signage - Wall 3 allowable signage - Site Plan S4 kTrAwrt 0 square feet square feet square feet feet 47, rN Z7, C -X 11i A 1ACA-1,16t4 MAMC,4,4t-c' I rr I A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: jW 5 Job Address: Ll g 4 Ej Mcc r sL Permit Number: a LDl (n 0 I (-, U_J El No one available for inspection: Time 1 (AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date:/ a / u / Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE �9r(303) Building Inspection Division (303) 234-5933 Inspection line 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: -.,r- J Job Address: 14 914 (Y)40 Permit Number: � ; I �� d 160- 0 No one available for inspection: Time 6PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector A 1 n DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE 1Building Inspection Division (303) 234-5933 Inspection line �(303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M1 5 / Job Address: K9V 5 n?#95NA1L 51- Permit 7Permit Number: 20/6 01626"7 vnh v* ❑ No one available for inspection: Time�� Alaj , Re -Inspection required: Yes No * When corrections have been made, call for re -inspection at 303-234-5933 Date: - J ( Inspector: DO NOT REMOVE THIS NOTICE FOR OFFICE USE ONLY Date.* C',it, CA, �0 0 Building & Inspection Services Division ) 1( 7500 W, 29"' Ave., Wheat Ridge, CO 80033 Plan Review Fee., Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line- 303-234-5933 C) Email:perMA§O_ciwh PAID Building Permit Application (6., Please complete all highlighted areas on both sides of this fbrm. incomplete applications may not be processed. 4949 Marsh e�)o����nthony@sitmeanssit.coni Bectrical, Gambrell Enterprises, Inc, W, R , City License # Other City Licensed Sub: City License # Plumbing" pooite�,� WR City License # Other City Licensed Sub-, Cfty License At Mechanical: i,4ej4v_ WR City License # Complete all information on BOTH sides of this form QOM Ia .. [j RESIDENTIAL COMMERCIALNEW COMMERCIAL STRUCTURE Q ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE 0 COMMERCIAL ROOFING RESIDENTIAL.REPLACEMENT COMMERCIAL REPAIRRESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEWPPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEMIAPPLIANCE ELECTRICAL SYSTEM4�,,PPLIANCE RRPAIR or REPLACEMENT Demo existing office area, add new office area, add new kennels, Sgrc FULFa _.. ,. _ Gallons Amps fair ' : �t�trrrtrt ia� car the f l frit aanri lair "sn�laatftf in the a lrra�jt OWNER/CONTRACTOR SIGNA UNDERSTANDING AND AGREEMENT t icreby ccriif ° that die setback distances prtalme by this permit application aacc raatc aarrcl do not violate applicable or iraaaaac e,"i, miles or rt.gaalaations of the City of Wheat Ridge or cowmants> easemnts Jaz restrictions ofnxor ; that all measurernmts slaoxaaa and allegations raazacic are ,accatraatc; that :l have read and as reav to abide by all crartcliticaw printed on this application and tlaaat f assume wall responsibility for coaaf ii inc aaitla applicable Cit of haat iefgex cods and ordinances for work under any lrcrartit. issued taaas i Baca this applic.aatic>ra thataarar thec legal c, aacr or have lxxe en aautlacarize d try° the Ie -gal camm rr of the paaapaly to lxr4<>nn the described vvork and arras also autilorized lay," tlac legal o"Mer Of aariv entity included on this aapptic tieara to list that entity on this application,1, the applicant for this building pr sit application, ° aiTaarat the truthfulness of the, iaal"a>nnaatieart l axwialeaaf on dieapplication, IR ONE `ffWN t:;OWRA " 'ORj or t � i al? ` '1' ,'a 'a ° 1" i' of OWN I0 "1)111T ) 1 a 1 12 Ildectmaic Signature (first a:a r fa kT Valuation:Building Division PLUMBING COMMENTS (2012 IPC) 1) All new plumbing to be installed to the 2012 IPC by a State and city licensed plumbing contractor. 2) Provide backflow protection on all possible cross connections. This includes any threaded faucets such as mop sinks, and soda dispensers or carbonating dispensers which require a RP device. Maintain airgap at dishwasher I" inimum. 3) The washing machine shown, if a commercial machine will require a lint trap 4) The restrooms may not be unisex except as an additional restroom to the minimum. Section 2902.2 (2012IBC) requires separate facilities for each sex. In addition, the shower shown in the restroom must be accessible. Note: The minimum number of toilets is 2 each for mate and female, sarne for sinks. 5) The tub shown in the Kit/wash area must be designated animal wash only unless accessible. 6) Maintain I" airgap at dishwasher, MECHANICAL COMMENTS (2012 IMC) 1) All mechanical work to be done in accordance with the 2012 International Mechanical Code by a State and City licensed contractor. 2) Provide smoke detectors in the return air plenum per Section 606, 2012 IMC. 3) Provide mechanical ventilation in bathrooms. ELECTRICAL (2014 NEC) 1) All new wiring for the retail spaces to be as per 2014 National Electric Code. By a State and City licensed contractor. 2) Provide strict adherence to the attached com check. 1) Satisfy the requirements of the West Metro Fire Protection District plan review notes EMM 2) Separate pennits are required for awnings, signs, hood extinguishing systems, any outside work, and fire sprinklers. m MW IIII r PLAN LREVIEW 7-mmlln Project: Sit means Sit Address: 4949 Marshall Pl. Type of Construction: V-13 Non Sprinkled Occupancy Load: 82 Date: 10/27/2016 Use: Dog boarding Occupancy:B Permit #: 201601607 PLAN REVIEW COMMENTS (based on the 2012 International Building Code) Reviewed by: Jim Johansen For Inspections, call (.303)234-5933 NOTE: Any additional comments on the building permit card are a part of this review. Description of Project: This is a tenant finish in a previously finished building to be used as a dog boarding and training facility. A Certificate of Occupancy or a Temporary Certificate of Occupancy is required prior to use, training, occupation or stocking of this unit. A certificate of Occupancy will be issued for this project. A building, facility or element that is altered must be made that to comply with the applicable provisions in Chapter I I of the 2012 IBC. New tenant finishes require compliance without exception. It remains the owner/occupants responsibility to provide access and compliance with all ADA requirements. Final authority and enforcement is ultimately the responsibility of the Department of Justice. This occupancy is required to be accessible. Specific Comments: STRUCTURAL COMMENTS - (2012 IBC) 1) If any hearing walls or columns are removed, engineered plans must be provided to show the modifications and to verify that it is done in accordance with the 113C. 2) The building must be made accessible as per the 2012 IBC 3) Planning department approval is required for any exterior changes. No exterior changes are approved with this permit, Provide detail for guard at loft where open to below. 4) There appears to be a floor drain in the kennel area. If this is a wall then there is 48" clearance at each end required. CITY OF WHEAT RIDGE D Ridge,7500 W 29th Ave Wheat p. ` w1MEMEM 4 111; 1 ii� 11 3= A copy of this form must be completed by each agehc� indicated on the Permit Submittal Checklist f the project r be attached to the Building Permit Application at the time of submissio Applications presented for submissions • • ,d Proof of Submissionform from •; r agencyot be accepted or •• k r • iN pl III ` I u°j � II � VIII I� �I IUI i; t ���• sc s � �_ +► AQgDQtjCAMWJjj9d; (Please check one) V'West Metro Fire Protection Ridge* Arvada Fire Protection * Wheat Water District Consolidated * Valley Water District o Denver Water Agency Notes: authorized ► W"elow,hereby acknowledge of documents indicated• * Wheat Ridge Sanitation* Clear Creek District Fruitdale Sanitation * Westridge Sanitation District c, Other Signature: Date: (Agency Representative) Email: F City of Wheat Ridge Commercial Demolitio PERMIT - 201601664 PERMIT NO: 201601664 ISSUED: 10/24/2016 JOB ADDRESS: 4949 Marshall ST EXPIRES: 10/24/2017 JOB DESCRIPTION: Interior demolition of office space; approx 6000 sq ft *** CONTACTS *** OWNER (303)422-3647 ADDYX ENTERPRISES LLC GC (720)882-3510 Robert Leach 110238 Red Hill Construction Services *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: / SUBDIVISION CODE: 343 / BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 35,000.00 FEES Total Valuation 0.00 PAID Demolition Fee 50.00 ** TOTAL ** 50.00 *** COMMENTS *** *** CONDITIONS *** All work shall comply with applicable codes and ordinances and is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I f er attest that I am legally authorized to include all entities named within this document as parties to the work to be performed a)x>t all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanyingplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180.days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code o a ordinance r regulation of this jurisdiction. Approval of work is subject to field inspection. v Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat Midge COMMUNITY DEVELOPMENT Building $ Inspection Services Division 7500 W. 29`h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(aki.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # + �0 1 (0C Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: i�4' `�'w'>l'�'y�� Property Owner (please print): Phone: Property Owner Email: Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer �k Architect/Engineer E-mail: Phone: Contractor l� ( �� (n�, S L- L A Contractors City License #: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ADVANCED ENVIRONMENTAL CONSULTING TRUSTED ENVIRONMENTAL SPECIALISTS 308-257-8994 (0) WW.SCOREAEC.COM AEC@SCOREAEC.COM (E) LIMITED SCOPE ASBESTOS INSPECTION REPORT Project Detail Project I.Awation. 4949 Marshall Street in Wheat Ridge, CO Kwi Performed By: Seth Kisselman Inspection Date. October 18, 2016 llcport Date. October 20, 2016 lll�ted TU Anthony B i -act iante Sit Alcans Sit, Dog'1'raining 4949 Marshall St Wheiit Ridge, CIO 800.43 Prepared Br. Advanced Environmental Consulting, ITC Colorado Cpnsulting Mrm#: 20874 7751 Fast 1371i Aveime 'niornton, (Y) 80tit12 Advanced Environmental Urnsniting, LL(' (AEQ was retained to collect asbestos samples at the. above- rel'erenced property and provide a limited scope asbestos building inspection report. The asbestos survey included Milk sampling of susWt asbestos -containing material (ACM) and the submittal of samples for asbestos content ha wmatory analysis. The purpose or this inspection was to sample suspect ACIt that would he disturbed by resonation activities and to have laboratory analysis identify whether the suspect material(s) contained asbestos. 2.0 OBSERVATIONS AND SITE DEBCR>PTION The asbestos survey was conducted on October 18, 2016 by Colorado Department of Public Health and Environment (('DPIIE, ) and Asbestos 11 mued Emergency Response Act (AIlERA) certified asbestos building inspector Mr. Seth Kisselman (Certification Number 21329). Information provided to AEC indicates that the building was avnstructal in 1983. The building is a single -story commercial dwelling. Destrncti ve sampling was conducted on the materials p1mied to be disturbed. a0 SAMPLING AND ANALYTICAL PROCEDUPM The inspection and assessment were performed in accordance with I+'nvironmental 1'rotection Agency/A H Pf,11A recommended procedures. These pixxAures call for the visual inspection of all areas of concern and collection and analysis of representative bulk samples of suspect material. Random bulk samples, representative. of the suspect asbestos -containing building materials (ACBM) of each homogeneous area (HA), were colloctel according to the guidelines published as Environmental I'rotoction Agency (EPA) Final Rule.* Title II of the Toxic Substances Control Act ('[BCA), 15 US(', Sections 2641 through 2614 and in compliance with 40 CFR, Part 763. Representative sampling is bayed on the following criteria!; L The distribution of the suslwt material throughout the HA. t3. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyze] should be considered representative of materials in each HA if: 1. They exhibit similar physical characteristiN and 2. The application of the sampled material can be correlated to the application of un -sampled material. AEC collects samples by tvlxh of texture. Not every nxam with each texture may have lxxen Ustt4l; however, it is ai�tiauued tole pxositi� c if' it L.ati the saanae texhrrP:aa; tJae aaluove-refererued types AEC uses llr'ywallsc+hcxrl.cuu/texhrres or drterroainr the texture labels 1+'or t.hernaal syytrm insulation sampliut;, .% HX IIsrS tllr llnagra tRb t117011gll o()gIe. Bulk samples collected were analy7A utilizing the MIA's Method for the Determination of Asbestos in Bulk Building Xiteria is (EPA 600/1/116, July, 19M) and the hleCrone Resmxch Institntes The Asbestos Particle Atlas as methods references. Analysis of the bulk samples was performed on the "date reported," as listed in the bulk - sample analysis report 4.0 SAMPLING QUANTMBS AEC collected at least the minimum number of samples from each homogeneous weaa necessary to meet all regulatory requirements for the quantity of material to be disturbed. The quantities listed in this report are approximate and on-site verification of the exact quawtrty of each material is required. The following outlines the minimum sample quaantihos required per homogeneous ama: • SulfnciV J1ateriah; (.SV' up to 1,000 ft' of material requires a minimum of three (3) tramples; between 1,000 ft' and ::,0011 ft' of material requires a minimum of five (5) samples; over .5,000 ft' of material requires a, minimum of seven (7) samples; one (1) saanaple of P.•ach patch. mtA: HA: B Si slwt ACM Deseription: Drywall -Orange Peel Suspect ALAI Description: Drywall -Rough Stispect ACM IAwation(s� Entry, Employee Lounge, Suspect ACM L.)rution(s� Shop Bathrooms Sample bwation(s): Shop East Wall Sample IAxntion(s): Entry Bathroom Walls, Employee Bathroom Classification: Surfacing Material Condition: Good (lassification: Surfacing Material Estimated Qitantit): 18 W Condition: Good Fniability: Friable �g 141stlmatod Qnantlt�: 125 ft$ R-iabilit ': Friable "A: C "A: Snslxx t ACM Description: VCr Tile Grey Suspect AC11I Iewription: Siusl"I ACM I.oeation(s): Entry, Employee Lounge, Suspect ACM 1 ueation(s� Bathrooms Sample IIX ation(s� Sample I. x-athon(s): Employee Bathroom Classification: (Ylassiflcatlon: Miscellaneous Condition: Condition: Good Estimated Quantity Estimated Quantity: 15 fts Friability. Friabilit . Friable HA: HA: Suspect ACM DeM+ription: Suslxvt ACAI D"-ription: S %pest ACM I.cx ation(s� Suspect A(W Lc)cation(s) Sample 1"ation(s): Sample lmjttion(s� Classification: (lassification: (condition: Condition: Estimated Quantity. Estimated Qiiautit3: Friability: Friability: TI IELt Snspeet ACM Description: Suspect ACM De x ription: Suspect ACM 1".ation(s� Suslvet ACAI l"ation(sy Sample IL ocation(s): Sample Lo ation(s� ( 1a35illcatlon: Clamification: (bndition: Condition: Estimated Quantity: Estimated Quantity. Friability' Friability: HA: HA: Suspect ACM Description: Suspect ACM Description: Snspect ACW I.,ocation(sy Suspect A(.`%f DA)cation(s) Saml►le Ddlcation(s): Sample liwation(s): Classification: C1.tssificat i4) Condition: Condition: Estimated Quantity: Estimated Quantity. Ftiabihty: Friability- Per CDPFfF. Demolition Permit. Demolition of a building that has non-friable asbestos-containing materials remaining must be completed without causing the asbestos-containin; materials to become friable Burning a btWding with any ask-stos-containing materials is prohibited. Concrete floors covered with floor tilt shall be irmoved in as large sections as possible. Operations such as crushing, pneumatic.jacking, etc of materials containing asix-stos are not twrmittcel. liecycling, of materials, such its concrete or wool, that are bonded or cont unutated with asbestos-containing materials such as floor We or =wtic, is not permitted. 1&0 T DATIONS This report describes the data collected and observations made by AEC during the visual imspection and bulk sampling in the above referenced building, AW, represents that its services were performed within the limits prescribed by applicable ivgulations, within scope of work as approved by the EPA and the State of Colorado and in a rummer consistent with the level of care and skill ordinarily exercised by other professional consiulta.nts under similar circumstanne A W. accepts no responsibility for data collected, the recommendations made or expressed to the client, and/or other commitments made by persons or firms other than ABC No other representation is made to the client, expressed or implied, and no warranty or guarantee is included or intendeL Thank you for the opportunity to provide Mr. liraeciante industrial hygiene services. If you have any questions on this limited scope asbestos building inspection, please contact me at your earlid--t convenience. ResImutfuI1Y Submitted, 14DYANCED ENYMORMNTAL CONSULTING .lam_ Seth Kissel ma,u hdadLrial Hygienist CABY 21329 E- AddL R _ Reservoirs Environmental Inc. T October 19, 2016 Subcontract Number: NA Laboratory Report: RES 363474-1 Project # / P.O. # Anthony Bracciante Project Description: 4949 Marshall St. Seth Kisselman Advanced Environmental Consulting (AEC) 7751 E. 137th Ave. Thornton CO 80602 Dear Customer, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 363474-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, )*40 ,it. Dauid"n Jeanne Spencer President P: 303-964-1986 5801 Logan Street, Suite 100 Denver. CO 80216 1-866-RESI-ENV rn K \ { / \ } 0 \ / / / K \\ } $ 7 E a\ U// / m /j J / d �} e ƒ i a 0 ` 3 2| 3 > x 2 f / ;( , m a) G m \ \ \ - c §! ] \ k 7 9 k ` 2 ® ® k > - CD \ \ > { � o @_ Co ƒ m e E v� G= CL m 0 [ \i f% /=w n § \ ] q k 8 ;_ ƒ 4 Q E \ $ 7 / \ \ 7 0 = e \ Q E ; , m E CD E ® n / _> xm«>r #M § o / Q / 2 ° 2 § 0 �::E q 2J X n ° k § $ m / & < « k \ \ I (m < z O � / \ §2 3 ■ rm / ]ƒ m & 2 Ln. 0 \/ \ �� \3 E 2 Z 4 3 � e m § ° 2 )> � r 2 n \\ � CD ƒ � E ........... n 2 o p > G 77 7 § ch D o t■; Do >&z � m _ — % 9� = 0 0 §f2 O f2 ƒ § / ]�f -R� 0 g / 7 }£2 > m >° �nyez aa; 2 00 ±}/{S /cm ƒ/ $§ M 2; 7 Ed :) }7 _ J \ / . () \\ } 2 0 r1l YJ `U Ai ATTACEIENT D CERTIFICATIONS W __ ttE- AhM1�lY)S l U�St. L I I W: FIkM rs�s.r AaRF%TIYS LAWRATORt �1.w(d! Mrw�l.l1'w.rllly. LL(' ASBESTOS CERTIFICATION* �1 �.. SeA B. iurdeua ��.. lssyMW�16:1NH (avr...�uudn..+�+.. fan U. odoivr:.. amus 4:Y ��1 �` weararsa•.. _�LIIa+rY[a.�v.a. Air MosluMN SNW-NO' rs�s.r AaRF%TIYS LAWRATORt �1.w(d! Mrw�l.l1'w.rllly. LL(' OEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 5787 BUILDING INSPECTION DI1/ISION - 235-2855 CITY OF WHEA7 RIDGE Date : 9/5/97 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : Property Address : 4949 MARSHALL ST Contractor License No. : 18141 Company : Denver Burglar Alarm Co. OWNER/CONTRACTOR SIGNA'fURE OF UNDERSTANDING AND AGREEMENT I hereby certiry that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or wvenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicabl heat Riolg or an s, for work under this permit. (OWNER)(CONTRACTOR) SIGNE` s DATE Description : INSTALL & MONITOR SECURITY ALARM BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval: Zoning : .W,~ Approvat : R~ ~ Approval : Occupancy : Walls : Roof : Stories : Residential Units : Phone : 456-5863 Phone : 292 2222 Construction Value : $275.00 Permit Fee : $25.00 Plan Review Fee : $0.00 Use Tax : $0.00 Total: $25.00 Electrical License No : Company: Plumbing License No : Company : Mechanical License No : Company : Expiration Date : Approval : Expiration Date : Approval: Expiration Date : Approval: .0 Iflom (1) This permit was issued in accor0anw with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regula[ions and Builtling Cotle of Wheat Ritlge, Colorado or any other applicable ordinances of the Ciry. (2) This permit shall expite if (A) the work authonzeU is not commencetl wilhin sixty (80) days from issue tlate or (B) the building authorized is suspentletl or abantlonetl for a period of 720 days. (3) If this permit expires, a new permit may be acquired br a fee of one-half the amount normally required, provitle0 no changes have been or will be made in the original plans and specifica[ions and any suspension.or abantlonment has not exceedetl one (i) year. If changes are matle or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work o( any manner shall be done that will change the naNral 9ow of water causing a draina9e problem. (5) Con[rac[or shall noUry the Building Inspector twenry-four (24) hours in advance for all inspections and shall receive written approval on inspection wrd before proceediing with successive phases of the joD. (6) The issuance of a permit or the approval of drawings and specifications shall nof be construed to be a permit fa, nor an approval o(, any violation of the provisions of the, building codes or;any otper ordinance, law, rule or regulation. iief Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT UF PLANNING AND DCVELUF'Mtfv I tsuuainy rermic rvwiwel . BUILDING INSPECTION DIVISION - 235-2855 Date : 9/3/97 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : Clear Creek COllision Center Property Address : 4949 ►+u*-a►al1 Street., *~eat Ridqe OD Phone : 80033 Contractor License No. : 18141 Company : De►ver Burglar Alarm ComPany.i Inc. Phone : 292-2222 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby wrtify that lhe setback distances proposed by this permit appliwtion are accurate, and do not violate applicable ortlinances, rules or regulations of the City of Wheat Ridge or covenants. easements or restnctions of record: that all measuremenls shown. and allegations made are accurete; that 1 have read and agree to abide by all conditions printetl on this applicalion, and that I assume full responsibility tor compliance with the Wheat Ridge 8uilding Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTR4CTOR)SIGNED DATE 9 3 97 Description : INSTALL ADID MM 7OR SEQIRITSC ALARM CNLY. ConsUuction Value : $ 275.00 Permit Fee : $ 25.00 C-01084 Use Tax : Total: $ 25.00 BUILDING DEPARTMENT USE ONLY ~ Approval: Zoning : INllitlM' .UM Approval: ~IbIfC!W~:O~ttlents;; Approval: I Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company: Company: Company: Expiration Date : Expiration Date : Expiration Date : Approval: , Approval: Apprcval: Pllns Required P~ans RBqulretlt«:;;7 PIKns:Required_`-.;_I J (7) This permn was Issued in acwrdance wilh the pmvisions set forth in yo0ur apptifation antl ia sublect to Ihe lawa of ihe Stale of Cobratlo antl to Ihe Zoning Re9ulatians antl Builtling Code of Wheat Ridge, Colorado or any other ap0liwble orEinances of lhe Ciry. (2) This permit shall ex0ire i1 (A) the work autnorized is not commenceE wlthin sixry (60) daya irom Issue dete or (B) ihe builOinB euNOnzetl Is suspenEetl a abandoned lor a periatl of 120 days. (3) II this permit expires, a new permit may De acquiretl ror a lee of one-half Ihe amount normalry required, Oravitletl no changes have been or will be matle in Iha onginal Olans antl speclfimalions antl any suspension or abandonment has not exceeded one (1) yeac If cAangea ere made or if suspen6lon a aban0onment exceeds one (1) year, lull lees shall he paid tor a new permit. (4) No work of any manner shall be Uone Ihat will change the natural Ilow of water wusing a drainage pmblem. (5) Contracror shall nollfy the Building Inspeclor twenry-tour (24) hours in atlvance lor all inspecUOns and ehall recerve written approval on inspeUion wrE Oetore proceeAiing wilh successive phases of the jab. (6) The issuance of a permR or the aOProva1 of drawings anE speciliw6ons s0all nol Ge conslruetl to be a pertnit br, nor an approval ol. any viola6on of Ihe prohslon: of the Cudding codes ar any olher ordinance. law, rule or re9ulation. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION