Loading...
HomeMy WebLinkAbout4568-4570 Hoyt Streetr City of Wheat Ridge Residential Roofing PERMIT - 201705310 PERMIT NO: 201705310 ISSUED: 08/02/2017 JOB ADDRESS: 4570 Hoyt ST EXPIRES: 08/02/2018 JOB DESCRIPTION: Residential Re -roof to install GAF asphalt shingles - 35.7 sq *** CONTACTS *** OWNER 303-532-9083 ELLIOTT JOLEEN SUB (303)750-4295 Seth Curry 170393 4th Dimension Concepts *** PARCEL INFO *** ZONE CODE: I UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 13,901.00 FEES Total Valuation 0.00 Use Tax 291.92 Permit Fee 267.70 ** TOTAL ** 559.62 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. 20Q5aCG INSPECTION RECORD INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Occuvancy/TvDe Inspections will not be performed unless this card is posted on the project site. "Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof 9 Lath /Wall Tie Rough Electric' Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors 74- to Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Roofing PERMIT - 201705310 PERMIT NO: 201705310 ISSUED: 08/02/2017 JOB ADDRESS: 4570 Hoyt ST EXPIRES: 08/02/2018 JOB DESCRIPTION: Residential Re -roof to install GAF asphalt shingles - 35.7 sq *** CONTACTS *** OWNER 303-532-9083 ELLIOTT JOLEEN SUB (303)750-4295 Seth Curry 170393 4th Dimension Concepts *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT*: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 13,901.00 FEES Total Valuation 0.00 Use Tax 291.92 t._. Permit Fee 267.70 ** TOTAL ** 559.62 - *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. 1. t 4 4, City of Wheat Ridge Residential Roofing PERMIT - 201705310 PERMIT NO: 201705310 ISSUED: 08/02/2017 JOB ADDRESS: 4570 Hoyt ST EXPIRES: 08/02/2018 JOB DESCRIPTION: Residential Re—roof to install GAF asphalt shingles — 35.7 sq I, by my signa re, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable bui ding codes d all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal o ner oft r perty and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I rther est I am le ally authorized to include all entities named within this document as partes to the work to be performed that 1 w be erformed is disclosed in this document ancj/or its accompanying approved plans and specifications. SigLbUt f i�or CONTRACTOR (Circle one) Date ' 0 1.rm' s issued based on the information provided in the permit application and accompanying plans and specifications and is to he compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. it shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building l and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or ranting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable ny ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 5*W® �f . _ e Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz "70170 53l 0 From: no-reply@ci.wheatridge.co.us Sent: Monday, July 24, 2017 2:30 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? I ns � t" Z I 1 How many dwelling units Duplex are on the property? PROPERTY INFORMATION Property Address 4570 hoyt st Wheat Ridge, CO 80033 �✓ Property Owner Name Joleen Elliott f Property Owner Phone 303-532-9083 Number Property Owner Email Field not completed. Address �� 1 Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number 4th Dimension Concept DL 7206970232 Contractor Email Address jcontreras@4thdc.com Retype Contractor Email jcontreras@4thdc.com Address DESCRIPTION OF WORK Are you re -decking the No ✓� roof? Description of Roofing GAF , laminated shingles, Armor Shield in Pewter Grey Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 35.7 material selected above? Does any portion of the No property include a flat roof? If yes, how many squares Field not completed. on the flat roof? TOTAL SQUARES 35.7/ (pitched + flat) of all roofing material for this project 2 Provide additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract value or cost of ALL materials and labor) re move and replace asphalt shingles, pitch 4/12 13,90 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Jorge Contreras Email not displaying correctly? View it in your browser. 3 4th Dimension Concepts, LLC Pts Se'."W;V the owe /,® yelp'�� In N `giessllsE PR�R PRIMARY NE STREET ADDRESS SECONDARY PHONE `1�©_ zr77 - ?9eO D 6,033 EMAILADDRESS j© 14-6 11 :78 6� JHc2r�< CC�IyI INSURANCE COMPANY CLAIM # PROPOSAL DATE 7 - Scope Of or : (`�` ( 1 I Roofi Manufacturer `�' C- / oofing Product r0wr Sh e e i / Roofing Color Ted' Gr - $1,000,000 Liability insurance © egister "7 �G Manufacturer Warranty 4DC- 5 Year Roofing Labor Warranty :2"' =ZCity Building Permit off Layers) of Composition Layer(s) of spDecking& Attic ❑ Install Art New Decking Replace Damaged Decking Where Necessary I;11 Udrlayment �d $5 nstall Ice &Water Shield Olen Eaves &all Protrusions � " . g arter Course Shingles Gd'7 ;;Zrtifyv:Il:ys [elf 9n all Drip Edge (Colo +r t ) using _ �' '_"� ❑ Install Valleys — Closed—Open— (W) w Step Flashing (sidewall, chimney, skylights) ❑ Install Upgraded Ridge Vent System Zsta:ill Turtle Vents =aw ❑ Install Upgraded High Profile Ridge Cap 0 Install Design Course along Headwalls 06/weep Site with Magnetic Roller Classic Style Ridge Cap Vent Pipe Flashing (aka, jack or boot) Remove & Cover JU Detach & Reset Ciean Up Trash & Clean Out Gutters ❑ Other Additional Work/ Special Instructions: _ '0 ccP_ j/1dG Approximate Date(s) of Service: f� _ 1 S 7 Payment Terms: �4 (0 Dimension Concepts is not responsible for any property and casualty insurance carrier's delay or denial of an insurance claim, in whole or in part). WORK TO BE COMPLETED IN ACCORDANCE WITH THE SPECIFICATIONS ABOVE FOR THE COST OF: $ Dollars By approving this agreement, the property owner authorizes 0 Dimension Concepts, LLC to represent the best interests of the property owner for restoration of damages, a Dimension Concepts, LLC shall communicate with the property and casualty insurance company to come to an agreement for works to be performed. Following approval of claim, 0 Dimension Concepts, LLC will complete specified work for a price agreeable to the Insurance company and to 0 Dimension Concepts, LLC with no additional cost to the property owner except for the deductible, This agreed upon price shall become the final contract price, and 4t° Dimension Concepts, LLC wHI receive ii insurance proceeds for work completed by 4'" Dimension Concepts, LLC. The property owner is ❑lis not tending to make payment from the proceeds of a property and casualty insurance policy, Pursuant to C.R,S. Section 6-22-105, 4'h Dimension Concepts cannot pay, waive, rebate or promise to pay, waive or rebate all or part of any Insurance deductible applicable to the Insurance claim for payment for work on the covered property. 4a' Dimension Concepts shall hold in trust any payment received within financial Institution until the delivery of materials. Dimension Concepts Representative Signature 1730 S. Abilene St. Suite 204 Aurora, CO 80012 www.4thdc.com :-/1q11q-- Acceptance Date Acceptance Date Office: (303) 750-4295 Fax: (303) 459-5111 i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Q Job Address: 'i 1 % 51' - Permit Number: , /% OiEl JC2 ❑ No one available for inspection. Time ty I - / AM/PM Re -Inspection required: Yes No When corrections have been made, ca for re -inspection at 303-234-5933 Date: /` Inspector: % 7—ff DO NOT REMOVE THIS NOTICE I* � 4 i CITY OF WHEAT RIDGE _:��Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: por Job Address: q670 &V l- S f Permit Number: -20/706-320 ❑ No one available for inspection: TimeI! V _( AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234- Date:- ah %7 Inspector: MTO DO NOT REMOVE THIS NOTICE STOP WORK ORDER You are hereby ordered to stop work located at: By order of the City of Wheat Ridge Building Department for the following reasons: ) N SI A I -- L t IV L tti G ADO XJS A- o -C�jIZ �) zz- This notice may be removed ONLY by the City of Wheat Ridge Building Department! Date: '_ 1, Building Inspector C� . ° �) -/ /-'// Kimberly Cook From: Brian Tardif Sent: Thursday, December 29, 2016 2:27 PM To: Melissa Mackey; Brad Umbarger; Kimberly Cook; Michael Arellano Subject: SWO 4570 and4565 Hoyt street Follow Up Flag: Follow up Flag Status: Completed Categories: Red Category Window and door install both units Sent from my iPhone CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: G F l Job Address: yS70 H-0 ST Permit Number: 2 B f 7 ©c o 3 -7 ❑ No one available for inspection: Time /,/."/)0 /PM Re -Inspection required: Yes � JQ *When corrections have been made, call for re -inspection at 303-234-5933 Date: l"i B % Inspector:1r�%�K DO NOT REMOVE THIS NOTICE 4e'_�70 H'10�+ S+ - l' -0 (.gip V'M" 1� INSPECTION °'1 INSPECTION REQUEST LINE: (303) 234-5933 _u- mcv/Type Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections mate Inspector Comments Initials Pier Concrete Encased Ground (CEG) Inspections from these entities should be requested one geek in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Foundation / P.E. Letter Underground/Slab Inspections Cate Inspector Comments Initials Electrical Sewer Service Plumbing • , • ft=-Z1rT' - . .1 • [:Ti :?1 r•1 l MI --1 riM7m 11Orem IIr:MT6 171=774M. "171111111111 Rough Inspections Cate Inspector Initials Comments Wail Sheathina Inspections from these entities should be requested one geek in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Mid -Roof -- Fire Inspection / Fire Protection Dist. Lath / Wail Tie Final Electrical Rough Electric Final Plumbing Rough Plumbing/Gas Line Final Mechanical Rough Mechanical Roof Rough Framing Final Window/Doors Insulation Final Building Drywall Screw /Nail NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. Final Inspections Cate Inspector Initials Comments _ Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one geek in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For love voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. **For Inspection Time Window Requests — Please email insr)timereciuestC&-ci.wheatridge.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. 1ccupancy Is Not Permitted Until A Certificate of Occupancy Is Issue -i Protect ." From i CITY OF WHEAT RIDGE Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: & X I Job Address: '-( 5'7a if o 7- S r Permit Number: 2 o i -7 0003-7 ❑ No one available for inspection: Time % -w AM%PM, r Re -Inspection required: Yes 'No *When corrections have been made, call for re -inspection at 303-234-5933 Date: ! Inspector: DO NOT REMOVE THIS NOTICE i 1 _ . . 1 oL , I-. ri r, i -? nrVnn 1 `[ I v 11Yy if - T,7 O�v I t vvvv L'o),j- INSPECTION RECORD INSPECTION REQUEST LINE: (303) 234-5933 Occupancv/T ype Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Mid -Roof Concrete Encased Ground (CEG) Lath / Wall Tie Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Comments Sewer Service Plumbing Do Not Cover Under round or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date iectt InsInt Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. "For Inspection Time Window Requests — Please email insptimereguest(aDci.wheatridge.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather � INSPECTION RECORD (ISPECTION REQUEST LINE: (303) 234-5933 Occupancy/Twe Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Comments Sewer Service Plumbing Do Not Cover Underaround or Below/in-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath /Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. **For Inspection Time Window Requests — Please email insptimereauest(d)ci.wheatridae.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather CITY OF WHEAT RIDGE Building InspectionDivision (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: _568 Ffo,r/ T S -r Permit Number: 7-,o i 7 60 00 3 I- to ❑ No one available for inspection: Time �� 5;S�AQM/PM Re -Inspection required: Yesto *When corrections have been made, call for re -inspection at 303-234-5933 f- j/. 1-7 Date: Inspector: i) DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE f Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: wD Job Address: N 5-76 t 6V T S T - Permit Number: 2 c/ -700 00 2- 0 ❑ No one available for inspection: Time %0' ",5/ Z/PM Re -Inspection required: Yes _ o *When corrections have been made, call for re -inspection at 303-234-5933 � Date1 11 -!-7 Inspector: , s _dcG' ( ` DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Electric PERMIT - 201700037 PERMIT NO: 201700037 ISSUED: 01/10/2017 JOB ADDRESS: 4570 Hoyt ST EXPIRES: 01/10/2018 JOB DESCRIPTION: Install a new exterior sub -panel, replace a/c wiring which is not properly sized, install 2 new circuits to basement bath and family room area; 60 amps *** CONTACTS *** OWNER 303-532-9083 JOLEEN BUNT SUB (720)365-6040 Johnathon T. Matcham 130023 Matcham Electric *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 1,2.00.00 FEES Total Valuation 0.00 Use Tax 21.60 Permit Fee 50.30 ** TOTAL ** 71.90 *** COMMENTS *** *** CONDITIONS *** Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be per and that all work to be perfor ed is disclosed in this document and/or its' accompanying approved plans and specifications. Signatur of OWNER o CONTRALTO Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanyingplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, anew permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to f any inspection. //10//7 Signature of Chief B 1 �cial Date REQUESTS MUST BE MADE BY 11z59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of Wheatj�idge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY J Date: Plan/Permit# � ) -70002 Plan Review Fee: Building Permit Application "* Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 1%_70 �*(T Property Owner (please print): \V OLAN N� Phone:( 30 1 3 `t o�s3 Property Owner Email: Mailing Address: (if different than property address) Address: '32;5 /4,L l SoN ST' City, State, Zip: W lr"FAT(?_A 0(0G LO Architect/Engineer: Architect/Engineer E-mail: Contractor: C�:_�T-tZ A C Contractors City License #: Contractor E-mail Address: Sub Contractors: �^( Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: L-1 zc�-) �CvS'- X04 O Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Descrilption of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT El OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) N —Ij7d6, t... L p, Jv �v.� �� T� 2 0,2 '�?o V-2 1P W 1(2-w-4 to W t A ICtA- t S tv OT F(Lo f �-2 �1ZC I N V, -w CACuu ��S T c �j►�cT� 1 PSA , Sq. FULF Btu's Amps Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE.- PRINT NE. PRINT NAME: (OWNER) ONTnR^ACT.OR or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) kwx. SIGNATURE: �r� v v r. DATE: k l k() I ZONING COMMMENTS. Reviewer BUILDING DEPARTMENT COMMENTS - Reviewer. PUBLIC WORKS COMMENTS Reviewer PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION. Building Division Valuation: $ A City of Wheat Ridge Resid. Windows/Doors PERMIT - 201700002 PERMIT NO: 201700002 ISSUED: 01/03/2017 JOB ADDRESS: 4570 Hoyt ST EXPIRES: 01/03/2018 JOB DESCRIPTION: Replace (12) windows and (1) door; like for like *** CONTACTS *** OWNER 303-532-9083 JOLEEN BUNT SUB (720)309-2955 Lee McGonigal 160282 L & M Construction, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 3,250.00 FEES Window Replacement 50.00 Total Valuation 0.00 Use Tax 58.50 "A ID Investigative Fees 50.00 * * TOTAL * * 158.50 t-Vr71'-- —r—'-- *** COMMENTS *** *** CONDITIONS *** Windows shall comply with all applicable codes, have a .32 or better U -factor and shall be safety glazing if within a tub enclosure, less than 18 inches above the floor or within 24 inches of a vertical edge of a door. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as partes to the work toe performed and th tall work to be performeds-disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTR CTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Offcial and is not guaranteed. 4, No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chi f Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of Wheat�iclge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: 1?3117 Plan/Permit # U06006a_ Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Property Owner (please print): Phone: Property Owner Email: Mailing Address: (if different than property address) Address City, State, Zip: Arch itect/Enaineer: Architect/Engineer E-mail: Contractor: Contractors City License #: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: %C ' - �' 7 ` i33 Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION 0 WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) i-} / y J�t12eNtC' /4 is'tJ,Gou(.Gt'�' Sq. FULF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ ( `. cam _:)' ai (-) C''u OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that 1 am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAbtE: ��e- SIGNATURE:z DATE: ZONING COMMMENTS- Reviewer BUILDING DEPARTMENT COMMENTS. Reviewer. PUBLIC WORKS COMMENTS Reviewer PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION. Building Division Valuation: $ Customer Name: Remodeling Brokers Address: U.S. Building Supply, Inc 4391 York St. Denver, CO 80216 Phone: 303-298-1292 Fax: 303-298-1966 \Nww.usbsinc.com Phone: Fax: Customer Information: Comments: ITEM & SIZES LOCATION / TAG PRODUCT DESCRIPTION Line Item: 100-1 None Assigned Quantity: 1 RO Size: 72.125"X48.5" Unit Size: 71 62;"X 48" Quote Date: 12/12/2016 ■ M� Project Name Quote Name: leen # 4570 Quote Number: Order Date: Quote Not Ordered PO Number: St J0 F UNIT PRICE / EXTENDED PRICE ""` PRODUCT "` Row 1 Professional 5000 - 5800 3 -Lite Slider - XOX - 1 Units - 71.625W x 48H _.* DIMENSIONS 71 625W x 48H "' FRAME `" West, Vinyl, Frame Type - Finless. STC Rating - 31, Exterior Color - Adobe GTASS ""' Glazing Type - Insulated, Glass Tint - Clea. Law -E. Glass Strength - DSE, Thinplate Intercept *" SCREEN — Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed Separately - No "* HARDWARE Camlock 5800 3 -Lite Slider - XOX - CustomCustom ITEM & SIZES LOCATION / TAG PRODUCT DESCRIPTION Line Item: 200-1 None Assigned Quantity: 2 RO Size: 60.125" X 24.5" Unit Size: 59.625"X24" 5800 2 -Lite Slider - XO - CustomCustom "`PRODUCT*" Row 1 Professional 5000 - 5800 2 -Lite Slider - XO - 1 Units - 59.625W x 24H "' DIMENSIONS 59.625W x 24H *" FRAME *" West, Vinyl, Frame Type - Finless, STC Rating - 29, Exterior Color - Adobe — GLASS "* Glazing Type - Insulated, Glass Tint - Clear, Low -E. Glass Strength - SSB, Thinplate Intercept SCREEN — Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed Separately - No `*" HARDWARE Camlock — NFRC Series 5000 .SingleSlider, U -Factor 0.34, SHGC:'0 31, VL 0.58 --.— I.,. D.—I"', O—tu W—h— i11ARN) Parrac Unit Price: Extended Price: �11 UNIT PRICE / EXTENDED PRICE knit Price: Extended Price 1 of 3 Print nat.- 19119/9f10R 1 94 17 ITEM & SIZES Line Item: 300-1 LOCATION t TAG PRODUCT DESCRIPTION None Assigned Quantity: 1 RC1 Size: 60.25" X 24.5" Unit Size: 59.75"X24" r 5840 2 -Lite Slider - XO - CustomCustom "' PRODUCT ,<. Row 1 Professional 5000 - 5800 2 -Like Slider - XO - 1 Units - 59.75W x 24H — DIMENSIONS 59 75V+1 x 24H FRAME — 'Vest, Vinyl. Frame Type - Finless, STC Rating - 29, Exterior Color - Adobe — GLASS ' Glazing Type - insulated. Glass Tint - Clear. Low -E, Glass Strength - SSB, Thinplate Intercept — SCREEN — Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed Separately - No HARDWARE Camlock ... NFRC Series 5000.:SingleSlider, U-Factor:0.34, SHGC :0.31. VT :0.58 ITEM & SIZES LOCATION / TAG PRODUCT DESCRIPTION Line Item: 400-1 None Assigned Quantity: 1 RO Size: 60.25"X24.625" Unit Size: 59 75" X 24 125" �k ii #i' t "- PRODUCT — Row 1 Professional 5000 - 5800 2 -Lite Slider - XO - 1 Units - 59.75W x 24.125H — DIMENSIONS — 59.75W x 24.1251-1 — FRAME `"- 'Alest. Vinyl, Frame Type - Finless, STC Rating - 29, Exterior Color - Adobe — GLASS Glazing Type - Insulated, Glass Tint - Clear. Law -E, Glass Strength - SSB, Thinplate Intercept "' SCREEN — Screen - Half. Screen Mesh Type - Charcoal Fiber, Screens Packed Separately - No *— HARDWARE zz Camlock — NFRC — Series 5000 SingleSiider, U -Factor :0.34, SHGC :0.31, VT::0.58 5800 2 -Lite Slider - XO - CustomCustom ITEM & SIZES LOCATION 1 TAG PRODUCT DESCRIPTION Line Item: 500-1 None Assigned Quantity: 1 RO Size: 35.62.5" X 24.625" Unit Size: 35.125" X 24 125" _ w - i � • r T� _.. _._ 5 12 a -- - 5800 2 -lite Slider - XO - CustomCustom — PRODUCT "' Row 1 Professional 5000 - 5800 2 -Lite Slider - XO - 1 Units - 35.125W x 24.125H ... DIMENSIONS - 35 125W x 24.125H — FRAME — West. Vinyl, Frame Type - Finless, STC Rating - 31, Exterior Color - Adobe — GLASS Glazing Type - Insulated, Glass Tint - Clear. Low -E and Obscure, Obscure Placement - Full, Tempered Location - Full, Gl3ss$trength - DSB, Thinplate Intercept — SCREEN `"" Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed Separately - No .. HARDWARE Camlock — NFRC Series 5000 :SingleSlider. U-Factor:0.33, SHGC 0.31, VT :0.58 UNIT PRICE 1 EXTENDED PRICE Unit Price: w Extended Price UNIT PRICE 1 EXTENDED PRICE Unit Price: Extended Price: UNIT PRICE / EXTENDED PRICE Quoted by: Francrsc o Penaleza Quote Number: 1536820 Pages: 2 of 4 Unit Price Extended Price Print Date: 12/1212016 3:2417 ;TEM & SIZES LOCATION I TAG PRODUCT DESCRIPTION Line item: 600-1 None Assigned Quantity: 1 RO Size: 35 625' X 36 5" Unit Size: 35-125"X36" 0 "•PRODUCT.` ;-tow 1 Professional 5000 - 5800 2 -Lite Slider - XO - 1 Units - 35.125W x 36H — DIMENSIONS 35 125V1I x 36H " FRAME — West. Vinyl, Frame Type - Finless, STC Rating - 29, Exterior Color - Adobe "` GLASS Glazing Type - Insulated, Glass Tint - Clear, Low -E. Glass Strength - SSB. Thinplate Intercept *" SCREEN "' Screen - Half. Screen Mesh Type - Charcoal Fiber, Screens Packed Separately - No '*'HARDWARE '*• Camlock *" NFRC `•` Series 5000:: Single Slider, U-Factor.:0.34, SHGC.:O-31, VT '0.58 5800 2 -Lite Slider - XO - CustomCustom ITEM & SIZES LOCATION / TAG PRODUCT DESCRIPTION Line Item: 700-1 None Assigned Quantity: n RO Size: 32 125" X 16.875" unit Size: 31.625"X16.375" PRODUCT "' Row 1 Professional 5000 - 5800 2 -Lite Slider - XO - 1 Units - 31.625W x 16.375H — DIMENSIONS 31.625W x 16-375H "" FRAME "' West, Vinyl, Frame Type - Finless. STC Rating - 29. Exterior Color - Adobe "' GLASS Glazing Type - Insulated. Glass Tint - Clear, Low -E, Glass Strength - SSB. Thinplate intercept **' SCREEN — Screen - Half. Screen Mesh Type - Charcoal Fiber, Screens Packed Separately - No `*` HARDWARE Camlock ... NFRC Series 5000:.SingieStider, U-Factor:0.34, SHGC 0.31, VT :0.58 5800 2 -Lite Slider - XO - CustomCustom ITEM & SIZES LOCATION I TAG PRODUCT DESCRIPTION Line Item: 800-1 None Assigned Quantity: 1 RO Size: 32.125" X 16.875' Unit Size: 31,625"X16375" 5800 2 -Lite Slider - XO - CustomCustom —PRODUCT — Raw 1 Professional 5000 - 5800 2 -Lite Slider - XO - 1 Units - 31 625W x 16.375H "' DIMENSIONS 31 6250,1 x 16.375H `" FRAME — West. Vinyl. Frame Type - Finless, STC Rating - 31. Exterior Color - adobe GLASS Glazing Type - Insulated, Glass Tint - Clear, Low -E and Obscure, Obssu Placement - Full, Glass Strength - DSB, Thinplate Intercept Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed Separately - No —HARDWARE Camlock — NFRC Series 5000::SingleSlider, U-Factor:0.33, SHGC::0.31, VT::0.58 UNIT PRICE 1 EXTENDED PRICE Unit Price: Extended Price _ UNIT PRICE I EXTENDED PRICE Unit Price Extended Price UNIT PRICE I EXTENDED PRICE Unit Price: + Extended Price: _ Quoted by: Francisco Penaloza Quote Number: 1536920 Pages: 3 3t 4 Print Date: 12:1212016 3 24.17 i CITY OF WHEAT RIDGE Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 'D W `-D Job Address: �f _ -? Cs L ;> �- Permit Number: %�� 1 tP, 0 o ) � -7 ❑ No one available for inspection: Times' ;:) --,) I AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date:) � i C_ Inspector: r:__� :r� -Az t DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE ��9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax Inspection Type: INSPECTION NOTICE E M i Job Address: x/56 8 NO _/ r _ Permit Number: ZofG 0 12-9 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes Jo *When corrections have been made, call for re -inspection at 303-234-5933 Date: 12-��-j InspecibK.. DO NOT REMOVE THIS NOTICE "i CITY OF WHEAT RIDGE '' Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: GM )2— Job Address: 415-76 Mayr 5-r Permit Number: 2 ol6 o 110f 30 e ie -e4 5 1' ❑ No one available for inspection: Time * 05- A PM Re -Inspection required: Yes Co *When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Electric PERMIT - 201601929 PERMIT NO: 201601929 ISSUED: 12/07/2016 JOB ADDRESS: 4568 Hoyt ST EXPIRES: 12/07/2017 JOB DESCRIPTION: Remove existing Federal Pac. main service panel and meter. Install new 200 amp meter with bypass lever and new 200 amp main service panel. 200 amp. *** CONTACTS *** OWNER (303)532-9083 JOLEEN BUNT SUB (720)365-6040 Johnathon T. Matcham 130023 Matcham Electric *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,250.00 FEES Total Valuation 0.00 N> Use Tax 40.50 , Permit Fee 93.35 ** TOTAL ** 133.85 *** COMMENTS *** *** CONDITIONS *** Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed an tl t all work to be pe fon ed 's disclosed in this document and/or its' accompanying approved plans and specifications. tZ O-1 Z� Signat re of OWNER or ONTRACTO Circle one) Date I. This permit was issued based on t e information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be perfonned that shall results in a change, of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. Theissu ce,or granting of a ermit shall not be construed to be a permit for, or an approval of, any violation of any provision of any appl)1atll(kcode or any orcjinaIce or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest(�ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of Wheatl ,qge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 1 FOR OFFICE USE ONLY J Date: Plan/Permit # r,t b ,\ A2,0 Plan Review Fee: Building Permit Application "' Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. "` Property Address: rN Property Owner (please print): doL�N 5� Phone: ( ?L 32552- `(0e)j Property Owner Email: 1p`ee.rl-7$ ®0�ry 0,< <- Gcoryl Mailing Address: (if different than property address) Address: ALL_A5011_� ST City, State Zip: W HAP A1_t2_i C o E_ G0 Architect/Engineer: Architect/Engineer E-mail: Contractor: Ma-"CLVVl %-L Contractors City License #: Phone: Phone: (1?- i -3�" loC>40 Contractor E-mail Address: GOJv'\ Sub Contractors: Electrical:, r `ck�k `^^% Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE 1�ECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) O�> t—� (2 -EA -Ai � kpt L , (\/\CL t X SIC-(LQ�- C-% PSG l Sq. FULF Btu's Amps 2r—rp Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) ._. _ _ _ 00 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE- (OWNER)NTRACT or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) M �M PRINT NAME: OIr1�l0.:}�avt " a'4 SIGNATURE DATE: 1'2 dT �`� ZONING COMMMENTS Reviewer BUILDING DEPARTMENT COMMENTS. Reviewer. PUBLIC WORKS COMMENTS Reviewer PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION. Building Division Valuation: $ `'I �,5y . / City of Wheat Ridge Residential Electric PERMIT - 201601930 PERMIT NO: 201601930 ISSUED: 12/07/2016 JOB ADDRESS: 4570 Hoyt ST EXPIRES: 12/07/2017 JOB DESCRIPTION: Remove existing Federal Pac. main service panel and meter. Install new 200 amp meter with bypass lever and new 200 amp main service panel. 200 amp. *** CONTACTS *** OWNER (303)532-9083 JOLEEN BUNT SUB (720)365-6040 Johnathon T. Matcham 130023 Matcham Electric *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,250.00 FEES Total Valuation 0.00 Use Tax 40.50 Permit Fee 93.35 ** TOTAL ** 133.85 f�11ff,�t D * * * COMMENTS * * * *** CONDITIONS *** Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thisermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be perfor and tha all work to be perto ed is disclosed in this document and/or its' accompanying approved plans and specifications. &(M2 rc�N� k? -10 Zo l Signatur of OWNER*4ZET ircle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. Thispermit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to t - obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any appl�icaWe gbde or any ordinapceipr reggiation of this jurisdiction. Approval of work is subject to Field inspection. Signature of Chief Building Official `® Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest((—tci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of �/ Wheat -Midge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 ' Fax: 303-237-8929 Inspection Line: 303-234-5933 1 FOR OFFICE USE ONLY J rDate: Plan/Permit # i2X W R� 0 . Plan Review Fee: Building Permit Application "' Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ' Property Address: Property Owner (please print): V o' e_eN vj-r Phone: (3037 532 -CIO Property Owner Email: 1 -is ® GVM0" 1 com Mailing Address: (if different than property address) Address: �j� ":2 City, State, Zip: Arch itect/Engineer: Architect/Engineer E-mail: Contractor: f\(\ \ °AC_V_10Le"1 CA G Contractors City License #: Contractor E-mail Address: Sub Contractors: Phone: Phone:-z� X00 A 0 Electrical: \� lr C— Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE �E�ECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) k VAct� 1151-10111- IJ EW ZOO All -F \JJ V Sq. FULF Btu's Amps >oAQj Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) -Id0 •O - OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that 1 am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: SIGNATURE: DATE: DEPARTMENT USE ONLY ZONING COMMMENTS OCCUPANCY CLASSIFICATION. Reviewer BUILDING DEPARTMENT COMMENTS Reviewer. PUBLIC WORKS COMMENTS Reviewer PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required Building Division Valuation: ♦ i CITY OF WHEAT RIDGE r Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Far INSPECTION NOTICE Inspection Type: + V~ k OJ F Job Address: ~f -"70 *L~~ Permit Number: G2, ; /i ZL'b ^7 i1 r I l; f` ❑ No one available for inspection: Time L~U */PM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 1 t J n i Date: 711 Inspector: DO NOT REMOVE THIS NOTICE " 1 City of Wheat Ridge Residential Roofing PERMIT - 093281 PERMIT NO: 093281 ISSUED: 10/13/2009 JOB ADDRESS; 4568-70 Hoyt St `EXPIRES: 04/11/2010 DESCRIPTION:. Reroof: 29.5 sqs CONTACTS owner 303/674-4399 Steve Wilson sub 303./980-8808 Jose Rubio 01-8097 Rubio Inc./aka Rubio Roofing S PARCEL :INFO ZONE CODE: UA 'USE: UA SUBDIVISION:r 0251 'BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT 'VALUATION: 9,890.00 FEES Permit Fee 235.70. /7+,^: Total Valuation .00 ' 6I~ Use Tax 178.02 1, p TOTAL .:413.72 Conditions: 6 nail installation mid roof inspection required. Board sheathing spaced more than ?a 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield required from eave edge to 2'- inside exterior walls.. ***Coiltractor/Property owner shall provideladder(s) secured in place for inpsections.+ Subject to field inspection. I hereby cer ify,'that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, ulations of the City of Wheat Ridge. or covenants, easements or restrictions of record; that all measureme t shown, d a legations made are accurate; that I have read and agree to abide by all conditions printed on this application nd that I a ume full responsibility for compliance with the Wheat :Ridge Building Code-(I.B.C) and all other applicable eatRi e rdrnances, for work under this pe it~lans subject to field inspection. 3G Signature f contract /owner date L. This rmit was issued in accordance with the provisions set forth. in your application and is subject to the laws of the Sta e of Colorado and to. the Zoning Regulations and Building Codes of wheat: Ridge, Colorado or any.. other applicable old nces ofthe city. ? This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension maybe granted'. at the discretion of the Building Official. i. If this permit expires, a new permit may be acquired fora fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or :abandonment '-has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees .'shall be paid for anew permit', k. No work of anv manner shall be done that will rh - toP a,.~.- IQ STS MUST BE MADE BY 3PMANY BUSINESS DAY FOR :INSPE CTION THE 'FOLLOWING BUSINESS DAY. ~ I ~oF ""E'T~ City of Wheat Ridge Building Division m 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 C~<ORP~~ Inspection Line: 303-234-5933 Property Address; Property Owner (please print): Mailing Address: (irdifferent than property address) Date: Plan Permit#: Phone:) Cam/ - ~7 i TJ QO Address: M n City, State, Zip: Q ) a 0"e/) 04's, n r c rN L3 R yp~C Contractor: Contractor License Phnna- Sub Contractors: Electrical City License Company: Exp. Date: Building Permit Application -~~~0 Y7/71// Plumbing City License Company Exp. Date: Mechanical City License Company: Exp. Date: Use of space (description): tCQQ_Q d/g Description of work: Il 3 o y 6e~,`~ Sq. Ft./L.Ft added: Squares t ~ BTU's I Construction Value: 1, 4M - I (as calculated per the Building Valuation Data sheet) Plan Review (due at time of submittal): $ 1 Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby cert ify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) CO RAC _ or PERSONAL REPRESE ATIVE o O NER) (CONTRATOR) _ 134 PRINT NAME: ) c d SIGNATURE: o - Date: Bldg Valuation: $ BuildingPermit CITY OF WHEATRIDGE 7500 West 29TIl Avenue Wheatridge, CO 80033 303-235-2855 Permit Number 18807 6/6/2005 Insper;tion Line . 303-234-5933 Residential Mechanical PROPERTY 4568 OWNER: Joy Hardy Unit: (303) 423-2008 Hoyt 8t Description Replace furnace wi 90% efficient 45,000 btu condensate pupmp 1 IPaid 1$36.00 1$90.10 1$126.10 I ft\oo.ooL<fY\11 .<If?;X".\0 1 IPhone 1 13036688424 I I IDue 1$36.00 1$90.10 1$126.10 1 I I License # 122297 IFEES IFees luse Tax IPermit Fee ITotal Fees I ICONTRACTORS IName IMcCoy Boys' HVAC C!Jv ofWhept Ridae PRESCRIPTIVE ENERGY CODE BOILERS / FURNACES A MINIMUM OF 90% AFUE GAS WATER HEATERS A MINIMUM OF.GO ENERGY FACTOR ELECTRIC WATER HEATERS A MINIMUM OF .93 ENERGY FACTOR SETBACKTHERf,tOSTAT REQUIRED (EXCEPTHyDRONIC HEAT) R-21 WALLS . R-38 CEILINGS . R-19 CRAWLSPACES Units: Occupancy: Walls: Roof: Stories: Sq Feet: Ihereby certii)' that the setback dlsta'nces propos_ed by trnspennit application are accurate, and do Dot Violate applicable ordinanceS, rules or regullllionsofthe CitY of Wheat Ridge or covenants, easements or restrictions of record; that aUmwsurements shown, and aUegatlons made are accurate; that I have nad and agree to. abide by all cDnditiDns printed Dn this appllcatiDn, and that !assume fnll respDnsibility fo.reompliance wlththe Wheat Ridge Building CDde (U.B-C.) and allDther applicable Wh~::eEf"W"k~~ &-0&-0/1 (OWNER)(C"NTRACTOR). .......................~...... ... ... ....> S1GNEODATE 1 This pennlt was issued in accDrdance with the prDvisiDnsset fDrth inYDur appllcatiDn and is subject to. the laws ~fthe State DfColor~doalldto theZo~g Regnlations_an~:I.Bunding Code of Wheat Ridge, Colorado or any o,ther applicable ordinances: of the City. This pennit shaUexpire If(A) the work authorized is not commenced ,within sixty (60) days from Iss.uedate Dr (B) the bulldingailthorized is susPended or abandDnedJor a periDd oflZO days. 3 IfthiSpem,rlt expires; anew permit may be acquired fora fee of one:halftbe amount normally required, provided no cltanges have been or will be made in the Driginal PIl1Rl1 and specificatiDns and any suspension or abandonment has not exceeded one (l) year. Ifcbanges are made or ifsuSJl:ension or abandonment exceeds one(1} year, full fees shall be paid fora new pennlt. . 4 No work ofanymannershaU be dDnetbat will change tbenatural Dowofwater causing a dnlInage problem. S Contractor shall notify the Building Inspector twenty.four (24) boursinadvance for all inspectiDrul and sluillc_eceive written approvaion InSpectionwd biJtflr'e pCOCileding with successivep . b. ' , CbiefBnildinglnspector SIGNED DATE Page 1 ofl Monday, June 06, 2005 o ~' ~H(<r.... ~ " - " U ~ C'O(OO...tB COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE. 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) APPliCATION Building Permit Number: Date: Property Owner: Property Address: Contractor License No.: .:JO'j t-\""-(",~Y '-f(;t9l?' HDy--t -;.-r- , 'i50~'3 '.', Phone: 3,0:5 - 42.3 -200&- Company: Me co y \SOl's' HURL Phone: '1)-g - 6 G &' ":;-4' ;2-</ OWNER/CONTRACTOR SIGNATURE Of' UNDERSTANDING AND AGREEMENT Building DeDt Valuation Figure: $ I hereby certify thai the setback distances proposed by this permit appJication are accurate, and do nol violate applicab6e ordinances. rules Of regulations of the City of Wheat Ridge or oovenants. easements or restrictions of record; that al measurements shown. and allegations made are accurate; that I have read and agree to abide by an conditions printed on this applation and lhat I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.G) and all other applk:ab'e Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. Value:$ .2/0Q?oo Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ (OWNER)(CQNTRACTOR): SIGNED DATE (OWNER)(CONTRACTOR):PRINTEO DATE Use of Space (description): Description of work: I<e ~ l"" c.e \"0~ yv"c.e CO"'):<:?-">-"--"'"e. -r~; ""'I' (Ai -\- "'- '1D~ ~#;'(e,,,--t- 1'.5:00 () 'DT LJ / Sq. Ft. added BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ONING COMMENTS: Approval: Zoning: U1LDING COMMENTS: Approval: ue WORKS COMMENTS: Approval: IRE DEPARTMENT COMMENTS: Approval: upancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (4) (5) (e) This pennit was issued in accordance with the provisions set forth in your apptication and is subject to the laws of the State of CoIon>do and to the Zoning RoguIations and Building C-. of Wheat Ridge, Colorado or any other applicable ordinances 01 1heCIIy. This permit shan expire if (A) the work authorized is not commenced within sixty (90) days from issue date or (8) the buikting aulhorized is",-- '" aban<loned for a period of 180 days. If this permit expires. a new permit may be acquired for a fee of ooe-hatf the amount normally required. provided no changes have been ",will be made in the original plans and spocifications and any suspension '" abandonment has not exceeded one (1) year. n~ have been or n suspension or abandonment exceeds one (1)_. full 1_ shall be paid lor a new permit No -" of _ manner _ be done lhat will chango the naturalllow of _ causing a drainage problem. Conlracb' _ notify the ~ Inspoclo< ~ (24) hours in advance for all inspections and shall receive written appIOVlII on .~ cord __ proc:oeding wl1h __ phases of the job. Tho issuance oIa pennK '" the appmval of drawings and specifications shaI not be construed to be a perm~ lor. no< an approval of, _ violation of the provisions 01 the building codes '" any other ordinance. law. rule or regulation. All plan review Is aubje<;t to IIakllnapectlono. (1) (2) (3) Chief Building OffICial