HomeMy WebLinkAbout4535 Field StreetCity of Wheat Ridge E -Res. Furnace Replacement PERMIT - 202101196 PERMIT NO: 202101196 ISSUED: 06/04/2021 JOB ADDRESS: 4535 Field St EXPIRES: 06/04/2022 JOB DESCRIPTION: Replace 80% efficiency Gas Furnace in closet - 60K BTUs *** CONTACTS *** OWNER (303)420-1308 B JARNAS ON JEANN I NE SUB (303)578-3957 GAYLE FRUENDT 180142 FIX -IT GROUP, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KI PL ING , 1-70 & CLEARCREEK ARE BLOCK/ LOT# : 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,759.00 FEES Furnace Replacement 40.00 Total Valuation 0.00 Use Tax 225.94 ** TOTAL ** 265.94 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge E -Res. Furnace Replacement PERMIT - 202101196 202101196 4535 Field St ISSUED: 06/04/2021 EXPIRES: 06/04/2022 Replace 80o efficiency Gas Furnace in closet - 60K BTUs I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include al entities entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any pplicab e code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/04/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Furnace/Boiler Replacement Permit Application Date: Thursday, June 3, 20211:50:52 PM Furnace/Boiler Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or BOILER - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes replacement residential furnace or boiler like for like? PROPERTY INFORMATION Is this Residential or Residential Commercial? Property Address 4535 Field Street Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Jeanne 3jarnason (303) 420-1308 bjarnason4535@comcast.net CONTRACTOR INFORMATION Contractor Business Fix -It Group Name Contractor's License 180142 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 720-795-3146 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email fixitgroup@s1 permits. com Address Retype Contractor fixitgroup@s1 permits. com Email Address DESCRIPTION OF WORK What type of unit is Furnace being installed? Number of BTUs 60K What is the efficiency 80% (°%) of the unit? Is the unit GAS or GAS ELECTRIC? Where is the furnace or closet boiler located (for example, basement, crawlspace, etc)? Project Value (contract 10,759 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Kevin Ritter Permit Email not displaying correctly? View it in your browser. Good morning, ent the insurance to the anm.aca:d5drl wncafitloc so assmall yesterday .Itisattached again Also the payment form was attached to the application. It is also attached. Can you run the renewal with the permit fees? I sent two applications fol -4535 Field Street Ione for Furnace and one for AC) ibanksl From: Comm0ev Permits <Eld tEdl wheatrdee ad as Sent Friday , lune4, 2021 754AM TO: Hv It Group <Frterounranoenn'rs m Cc : Commoev Perml<Eim tEdl whea Permits dge u, Subject: FW Coude Form Submittals Air Conditioner/Evaporative Cooler Permit Application Importance: High Good morning, Please update your contractor Ilcenae Por Mechanical. It Just expired 05/31/2021. Please send liability, workman's Comp, and fill out the electrode payment form attached. Please respond backto this email chain. Thank you, Vanessa Sanford Permit TechNoan Bunchng Division Office Phone 303-235-2854 Office Hours: 7am-4pm � ' hea Co�W tjjdge aunm Drnwrwturr From: no reply@ci wheatrdee cous mo -r pplv@c wheats Co dee ran Sent Thursday, lune 3, 2021148 PM To: Comm0ev Permits ee.mtEdl wheatrdee ad as Subject: Coude Forth Submittal Air Cond boner/Evapoative Cooler Permit Application Air Conditioner/Evaporative Cooler Permit Application This application Is exclusively for AIR CONDITIONER OR EVAPORATIVE COOLER YOU MUST ATTACH THE ELECTRONIC PAYMENT FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit wilI be emailed to the email address provided below once it Is pro cesseit THIS APPLI CATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTI L PERMIT HAS BEEN ISSUED. PROPERTY I NF ORM ATI ON Is this a new l nstal l or Replacement of Existing Unit replacement for an ago anon AC unit? Is this Residential or Residential Commercial? Property Address 4535 Field sheet Property owner Name Jeanne eiamason Property Counter Phone PON) 4201308 Number (enter WITH dashes, eg303123 4567) Property Owner Email barnason4535@comcasinet Address Attach City of Wheat Ridge Wheat Ridge Payment Form Electronic Payment Form - * DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTRACTOR INFORMATION Contractor Business Name Fix-It Group LLC Contractor's License 180142 Number (This is 5 or digit numberforthe City of Wheat Ridge) Contractor Phone Number 720-795-3146 (enter WITH dashes, eg 303-123-4567) Contractor Email Address fx'tgrouoldx 1 Perm'tscom Retype Contactor Email fx'tgrouol6)s 1 Perm'tscom Address DESCRIPTION OF WORK What type of replacement Air Conditioner unit are you installing? How many tons is the unit? 2.5 ForAC-what lsthe SEER? 14 SEER For Evaporative Coolers, what is the CFMs? Where Is the unit located backyard - insurance was sent to Contractors email (for example, rooftop, backyard on ground etc)? Is electrical needed for re- No hook? Project Value (contract 9,000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility Yes for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work may Yes not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that eve rythi ng Yes stated in this application is true a nut correct a nut that falsifying information in this application isanact of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Permit Kevin Ritter Email not displaying correctly? View it in your browser City of Wheat Ridge E -Res. A/C Replacement PERMIT - 202101187 PERMIT NO: 202101187 ISSUED: 06/04/2021 JOB ADDRESS: 4535 Field St EXPIRES: 06/04/2022 JOB DESCRIPTION: Replace 2.5 Ton AC unit in backyard - 14 SEER *** CONTACTS *** OWNER (303)420-1308 B JARNAS ON JEANN I NE SUB (303)578-3957 GAYLE FRUENDT 180142 FIX -IT GROUP, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KI PL ING , 1-70 & CLEARCREEK ARE BLOCK/ LOT# : 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 91000.00 FEES A/C Replacement 60.00 Total Valuation 0.00 Use Tax 189.00 ** TOTAL ** 249.00 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge E -Res. A/C Replacement PERMIT - 202101187 202101187 4535 Field St ISSUED: 06/04/2021 EXPIRES: 06/04/2022 Replace 2.5 Ton AC unit in backyard - 14 SEER I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include al entities entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any pplicab e code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/04/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. iU i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:�`� Job Address: c\ Permit Number: 2 ❑ No one available for inspection: Time ' "`-' AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date:_" ' , � e�L Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge >' 710�" E -Res. Window Replacement PERMIT - 201802509 PERMIT NO: 201802509 ISSUED: 09/12/2018 JOB ADDRESS: 4535 Field St EXPIRES: 09/12/2019 JOB DESCRIPTION: Replace 10 windows - 2 living room, 2 master bedroom, 1 office, 1 bath, 1 bath, 1 study, 1 sink, 1 laundry; u -value = .30; like for like *** CONTACTS *** OWNER (303)420-1308 BJARNASON JEANNINE SUB (303)945-1519 Matthew Seiler 180220 Seiler Construction *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 18,575.00 FEES Window Replacement 50.00 Total Valuation 0.00 Use Tax 390.08 ** TOTAL ** 440.08 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and{or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original_permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Mild ng Offc al i'' Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Ximberly Cook From: no-reply@ci.wheatridge.co.us Sent: Wednesday, September 12, 2018 12:30 PM To: CommDev Permits Subject: Online Form Submittal: Residential Window/Door Replacement Permit Application Categories: Kim Residential Window/Door Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WINDOWS and DOORS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM AND WINDOW/DOOR CUTSHEET (SPEC SHEET) IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes replacement window(s) and/or door(s) like for like? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address Attach Credit Card Authorization Form - **DO NOT ATTACH RANDOM DOCUMENTS** 4535 Field St Jeannine Bjarnason 303-420-1308 Field not completed. Narnason cc auth.pdf CONTRACTOR INFORMATION I Contractor Business Seiler Construction Name Contractor's License 180220 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-945-1519 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 1401 W Bayaud Ave (Primary address of your business) Contractor Email Address mbeaudoin@renewalcolorado.com Retype Contractor Email mbeaudoin@renewalcolorado.com Address DESCRIPTION OF WORK Number of window 10 and/or doors being replaced Location of (2)living room, (2) master, (1) office, (1) bathA, (1) study, (1) window(s)/door(s) being sink, (1) laundry, (1) Bath B replaced (for example, master bedroom, kitchen, bathroom, etc): What is the a -value of the .30 window(s)/door(s)? City of Wheat Ridge requires the a -value to be .32 or better on windows.. Attach copy of Biarnson, Jeannine measure.pdf window/door cut sheets showing sizes and u -value Project Value (contract 18,575 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for i compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Mackenzie Beaudoin Permit Email not displaying correctly? View it in your browser. mcm IN ONAR mmm ■■■■mm■®®mm�1®CHER mm M- I Belli Bell■ ■�©■■mm RES ■■®■mom mem■■m®mmm®��a■■■■■■■ ■�emmmm■®■■■®■■■■��■m®mm■s���a■■■■■■■ ■ R ■ mmm HER MINIM BEE■®■mmlpI■■�a■■■■■■■ mmm REN ■■®■®■ Wil•■m®mm■s ■��©■�■■■■■l ■ MMURNE ■■■MOM ■tel♦■m■mmt f■■�©■■■■■■■ ■ ■ ■m■mmm IN BEEN ■■■■®■■�■ mmm■i■■�©■■■■■■■ ■ ■■■■■■■■■■■■■■SEE M■■ ■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■�■■■■■■■ ■■■■■■■■■■■■■■■■■R■■■■■■■■�■■■■ll■ ■�■■■■■ SEEN ■■INNER ■■tom ■■■■■�■■■■■■ ■■■ ■ ■�■■■■■■■■■■■■■ SEE ■■■■■■■�■■■■■■■ IM ■■■■■■■■ ,■■■■■■■■i■_,■■■■■,■■■■■■�■■■■■■■ ■ ■■■■■■■■■■■■■■�■`■■■■■■ ■■■�■■■■■■■ ■■■■■■■■■■■■■■ ■■■ IN ■ ■■■■■ME MOM ■■ ■■■ ■■ ■ ■■■■■■■■INIM■ ■■■ ■■■ IS ■■■■■■■■■ MOM ■■■ ■■ ME SEN ■■■■ ■NEEM ■■■■■■■■E■■■■■ mom ■■EM! ■■■■ ■= IME■■■■■■■■ NONE ■■■■■■■■�■■■■■■■ ■■■■■■■■■■■MINES IME ■■■■■■■■■SON ■■■ 0■■■■■=1■■■■■■■ ■ ■■■■■■■■EM! ■■■ ■■■■■■ IME ■■■■MEMO ONE ■■■■■■■■■SEE ■■■■ ■■■■■■■■■■■■■■t NINE ■■ INE ME ■�■■■■■■■■■■■■■ ■■S ■■■■ ■�■■■■■ IME ■■■■■■■ IME IN ■■■■ ■�■■■■■■l■■■■■■ SEE M■■■■■�■■■■■■■ SEEM! ■■■■■IME MOM ■■■ IME ■■■■mom ■■■■■■ ■■■■■■ IME l■■■■■i■■S■■■■■■■ ■■■■■■ ■■■■■■■■■■■■■■t■■■■■■■■ ■■■■■■ ■ ■■■■■■■■■■■■ ■■■ ■■■■■■ ■ ■■■■■■■■■■■■ ■■■■■■■■■■�■■■■■■■ ■�■■■■■■■■■■■■■ ■■■■■■■■■■■�■■■■■■■ ■■■�■■■■i■■■■■■■■■ ■■■■■�■■■■�■�■�■i■i■■■■■ ■�■■■■■■■■■■■■■ IME■■■■■■■ ■■■■■ ■�■■■■ MEN ■■■�■■■■■■■ �-3 4-44—. 3S Fl>v� 5-�- INSPECTION RECORD °pancv'Tvpe INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection elr:� INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Sewer Service Foundation / P.E. Letter Plumbing nn Not Pour Concrete Prior To Aanroval Of The Above Inspections Underground/Slab Inspections Date Inspector Initials Comments Electrical Comments Sewer Service Plumbing n., KIM Cnvar I Inrlarnrniiind nr RPlnw/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof i !� U� i' `C Lath / Wall Tie Rough Electric' Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof ,t �r Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the rare vistrici and eiecuu:ai 10W vdnage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: /`'� Ku Job Address: F` .76;7d Permit Number: '7,/5tu 3y112 ❑ No one available for inspection: Time c U if A�,-�/PM Re -Inspection required: Yes fNo When corrections have been made, call for re -inspection at 303-234-5933 Date: �� �i' Inspector: MO. DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201703444 PERMIT NO: 201703444 ISSUED: 07/07/2017 JOB ADDRESS: 4535 Field ST EXPIRES: 07/07/2018 JOB DESCRIPTION: Residential Re -roof to install CertainTeed Landmark Impact resistant asphalt shingles with 24 sq. (18 sq. pitched, 6 sq. flat) *** CONTACTS *** OWNER (303)420-1308 BJARNASON JEANNINE SUB (303)426-7370 Kirk Tiley 021395 Tiley Roofing Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,401.00 FEES Total Valuation 0.00 Use Tax 155.42 Permit Fee 172.60 -- -- ** TOTAL ** 328.02 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201703444 PERMIT NO: 201703444 ISSUED: 07/07/2017 JOB ADDRESS: 4535 Field ST EXPIRES: 07/07/2018 JOB DESCRIPTION: Residential Re -roof to install CertainTeed Landmark Impact resistant asphalt shingles with 24 sq. (18 sq. pitched, 6 sq. flat) I, by my signature, do hereby attest that the work to be performed shall comply withal I accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am I?ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be�per formed„Is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying )tans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief B�itcia[- ft.3 Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Dan Schultz 20/763 From: no-reply@ci.wheatridge.co.us Sent: Monday, June 26, 2017 3:11 PM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Danny Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? L4 L rK p• 6;1&0 l ` How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 4535 Field St. Wheat Ridge, CO 80033 Property Owner Name Jeannine Bjarnason Property Owner Phone 303-420-1308 Number � :5 D_ �r- 0-x J I ON Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Tiley Roofing Inc. 21395 303-426-7370 Contractor Email Address mglenn@tileyroofing.com Retype Contractor Email mglenn@tileyroofing.com Address DESCRIPTION OF WORK Are you re -decking the No t/ roof? Description of Roofing Certainteed Landmark I/R Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 18 material selected above? Does any portion of the Yes property include a flat roof? If yes, how many squares 6 on the flat roof? 2 TOTAL SQUARES of all roofing material for this project Provide additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract value or cost of ALL materials and labor) 24 1/ Home, 1 Layer, 4/12 -Flat SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Michael Glenn Email not displaying correctly? View it in your browser. 3 ge A full-service. residential and commercial ROOFING and.gutter. confractor. TI+:Agf,N.pY.,lfit d[Wihei t?p4e1MEi xati4a>i+V na_e'11 _'i27n f_1 1 =nam? Proposal Date: 05/15/17 Field Wheat Ridge, CO 80033 Jobsite Address: Client Email: 4535 St. bjarnason4535@comcast.net Client Phone: Estimator: 303-420-1308 @tile oofing.com Ton Miller 303-249-8151 tony Yr Roof Area (sq. ft.): 2000 Roof Pitch: 4/12 -Flat Removal Layers: 1 There are multiple pages to this proposal. CO 80221 At Tiley Roofing we like to provide our clients with several alternatives to ensure you are getting the roof that best fits your needs. Below is a choice of a "Better" and "Best" package, several shingle product choices, and add on o ons to accommodate those need,. %y https /lana companYCam comloalleriesloFztt Roof Hyperlink Photos: dXkf3zA V J/ SCOPE OF WORK AND MATERIALS Existing Roof Condition: Hail damaged. Existing Leaks with Location: None reported. Demolition: Removal and disposal of existing layers (roof covering) specified above and 1 layer roof underlayment. Additional hidden layers may be difficult to determine until demolition process. Charges for these hidden layers may apply. Better - Standard Roof Package Underlayment: 1 layer of synthetic underlayment with 1 and 2 rows Ice and water on eaves installed per local building , 1 row at crickets, chimneys and skylights (if they exist). Flashing: 26 gauge factory finish bronze (dark brown) color drip edge, rake edge flashing, headwall, and step flashing. Replacement of all roofing jacks which will be painted to match shingles. Surface mounted visible flashing may be required at roof to wall intersections. Venting: Factory finish painted small animal proof roof vents. Nailing: 6 nails per shingle. Shingles: See choices below. Hip/Ridge: To match shingles. Warranty: Five - Year Workmanship through Tiley Roofing, OR Best - Upgraded Roof Package Underiayment: 1 layer of synthetic underlayment with Ice and Water at eaves, valleys, crickets, chimney and skylights. Flashing: 26 gauge factory finish color in your choice of white, charcoal gray, bronze, or brown drip edge, rake edge flashing, headwall, and step flashing. Replacement of all roofing jacks which will be painted to match shingles. Surface mounted visible flashing may be required at roof to wall intersections. Venting: Ridge Vent. Nailing: 6 nails per shingle. Shingles: See choices below Hip/Ridge: Raised Hip/Ridge to match shingles. Warranty: Five to Twenty Five -Year Workmanship through the manufacturer. Please call for details. Specific Job Notes and Details Existing roof covering CertatnTeed TL (Triple Laminated and 1/R) shingles highlighted below. Exact shingle is discontinued and unavailable, closest comparable match In bold below, please call for more details. Please let me know if you need assistance with your insurance claim (if applicable), would like to visit our showroom, have samples delivered to your home, or have any additional questions or concerns. Note available options listed below. Clarifications Prior to Contract Modified on flat roof. Solar panel removal and reinstallation by others (excluded by Tiley Roofing). Colors and options. Satellite Dish - detach & reset (excludes reception). Powered Fan. Schedule/Access. Page 1 of 3 Below are hyperlinks to connect you to the particular product you may be interest in, just click and go. There is also a general picture of the product. [DESCRIPTION OF AVAILABLE; OPTIONS Gutters/Downspouts: 26 gauge pre -painted Y K -style gutters and 25x3" corrugated downspouts. The same gutter configuration will be used unless otherwise instructed. Solar OR Electric Powered Fan: Furnish and install roof mounted 500 CFM (800 sq. ft.) solar powered fan center back side of roof deck. Modified on Flat Roof: Furnish and install perimeter flashing, base sheet and modified bitumen on flat roof. Below are hyperlinks to connect you to the particular product you may be interest in, just click and go. Please note this is for a general Product description. Specific product can vary in appearance based on manufacturer. add on to roof package Gutters Downs o add on to roof package Solar Powered Fan: $67 add on to roof package Modified on Flat Roof: a EXECUTE THE CONTRACT Ctient fo fill =onper Contract Amount: TBD based upon roof package and options Customer Signature: t / ^� J • �i2. / C?id � Shingle Type: ate, J Shingle Color:' Options: _ _ j / /^� ,, j r We must have all these items in order to schedule your project. _Confirm your selection with your HOA if applicable. _Please highlight the Roof Package and Options and write in the color selections. _Please return a signed copy also confirm you have read the terms, conditions, and information page. _We must have color and option selections to accurately schedule your job. _Please confirm all of your insurance claim documentation is complete (if applicable). a-,( S' C/"' Page 2 of 3 �! GtaL�,A is ti no i I Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11: 59 p.m. to receive an inspection the following business day. Inspector Must Sign ALL Spaces pertinent to this project Fo u ndation Inspections Inspector Comments Initial . . ..... ....... . . ........ Monolithic Stab Reinforcement poll Footing/Stemwall P.E. Letter Ins Underground/Stab Inspections ItIals *M # FT spections Inspector Initials Roof Sheathing Rough Electric Rough Plumbing Rou h Mechanical as ping Do Not Proceed Without A ove Ro __40 Inspections �o ugh Framing It Screw I Nail Inst nal Inspections pecComments Initials Final Electrical Final Plumbing ��chanical . ........ . .. ... Final Building Frame Landscaping & Parking I Planning Dept. Wil-wi I I ROW & Drainage / Public Works Dept. 111splOG111#115 CUR inspections call 303-235-2861. For fire inspections Fire Inspection / Fire Protection Dist. contact the Fire Protection District for your project, "Note. Ali items must be completed and approved by Planning, Public Works, Fire and Building before a CeiVricate of Occupancy is Issuect Approval of the Final Building Inspection does not constltute authorization of occupancy. Jun. 3, 2016 11:34AM Tiley Roofing No, 1593 P, a , . ►NiTY • uilding L)iWsion M` W, 2GP Ave.,• 80033 Inspection Une: 303-234-5933 Facsimile >.ng Pervolt APPOCatiOn property MOW. * « 10� IR * , « * . • � « �.. � . 1Cr'�rrrw � ,l r iM�Fdi. lw iiM +%il. «ftrent ,«w x«« MeilingAddress' city, we, zjP* --- « a � a +' # �... . * a ��tAt.•i .,rrNM,�� Ik. 1 zi * APPROVED Su4ject to Field Inspections I FOR OFFICE USE ONLY A A A I City of Whe-',at 14,j C c OMMUNFry DEVELOPMENT �11111111111 iiiiiiiiiiiiiiiij i iiiiiiiiiiiii ii[*,. P"eWperi Q--1A PlanftviewFee: A: o 11 l�! 1 11 gill l I I il� 1� 1� 1111111 1 li� 1� gill Address: +ft - 63 Other City Licensed Sub: 5,jiiivi I Other Ci L ty icensed Sub: u -4 ( City License # City License # Mechanical', WR Cit License # Complete all information on BOTH sides of this form Property Address: S FU F Stu's Gallons Amps Squares c City of Wheat Ridge 4535 Field Street 201401058 Pv System (Note: this sheet must stay with plans) Renus VS railing mount to L feet of roo ht it t4�Kgat. Burndy Wiley WEER ground C Run 1" EMT outsid of • nce with watertight connecto m APPROVED Subject i�- -Ike l pectic' ,, , Date; Page 2 of 2 Im m ExPEDITED PERMIT PROCESS FOR IN SYSTEMS MICRO-INVEWFER EXPEDITED PERMIT PROCISS FOR IN SYSTEMS - MICRO-INVEWFER ExPEDITED PERMIT PROCESS FOR SMALL-SCALE PV SYS MICRO-INVERTER The information in this guideline is intended to help local jurisdictions and contractors identify when FIV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50 %-75 % of all residential systems will comply with these simple criteria. bear projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval, Reqtdred Information Jbr Permit. 2 EXPEDITED PERA41T PROCESS FOR PV SYSTEMS --,- MICRO- I NVEK,rEP, SMISA5 Ad 1101 SSIDOIld llv"4 CHJACIJdX] 1 017 I 4 ExPEDI PERNUT PROCESS FOR IN SYSTEMS CO) G MC 9 t t' V d °W4pg+ Vim# k C 1 p $$ W 1 017 I 4 ExPEDI PERNUT PROCESS FOR IN SYSTEMS G t' k 1 017 I 4 ExPEDI PERNUT PROCESS FOR IN SYSTEMS I N I 0. • 0. 5 EXPEDITED PERMIT PROCESS FOR PV SYSTEMS o 1 0 4 - 0 H o i-- zo-n m C, z ZI - D o A • • N z Z' c. • 3 2 6 O o C rxi (b C4 M ZU =1 x c 00 , 1 m z o w z 0�- om om 0 mo —Z • o a m M 0 9 9 o mm 00 z m 0 z 0 mw z m 0 0 0 o mc c m m ;D 5 EXPEDITED PERMIT PROCESS FOR PV SYSTEMS 0. 5 EXPEDITED PERMIT PROCESS FOR PV SYSTEMS MENNEMMONNOM Enphasel Microinverters The Enphase M250 integrates seamiessly with the Engage Cable, the En Communications Gatewa)i and Enlighten", Enphase's monitoring and analysis software. - Optimized for higher-power modules - Maximizes energy production - Minimizes impact of shading, dust, and debris enphaseD E N E R G Y - No GEC needed for micro inverter - No DC design or string calculatior required - Easy installation with Engage Cable EM EnphaseO M250 Microinverter // DAT I DATA (ESC) M250- 60- 2LL- S221S231S24 Recommended input power (STC) 210 - 300 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V - 39 V Operating range 16 V - 48 Min /Max start voltage 22 V/48V Max DC short circuit current 15 Max input current 9.8 OUTPUT DATA (AC) @208 VAC @240 VAC Peak output power 250 W 250 W Rated (continuous) output power 2140 W 240 W Nominal output current 1A5 A (A rms at nominal duration) 1.0 A (A rms at nominal duration) Nominal voltage /range 208 V l 188.229 V 240 V 1211 -254 V Nominal frequency /range 50.0157 -61 H 60.0 / 57-61 Hz Extended frequency range" 7 -62.5 Hz 7 -62.5 Hz Power factor >0.5 >0.95 Maximum units per 20 A branch circuit 24 (three phase) 16 (single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency, 2401 VAC 96.5% CEC weighted efficiency, 208 VAC 9&0% Peak inverter efficiency 96.5% Static M PT efficiency (weighted, reference EN5O53O) 99.4 % Night time power consumption 65 mW max MEC�A FECAL DATA Ambient temperature range -40 °C to +65 Operating temperature range (internal) -40 °C to +85 °C Dimensions (WxHxD) 171 mm x 173 mm x 30 warn (without mounting bracket) Weight 2.0 kg Cooling Natural convection -too fans Enclosure environmental rating Outdoor - NEMA 6 APPROVED FEATURES Compatibility Compatible with 60- 9 P mo J&ferct to Field Inspections i Communication Power line Whe Integrated ground The DC circuit mee the requirements for ungrounded Pv rra} s in To learn more about nphase Mieroinverter technology, " visit E N E R G Y 2013 Erna . AM dghts reserved, API traderna or brands in This domsrent are regstered by their MsWtiye ownef, APPROVED Subject to Field Inspections A IV Whea I t Ridge Building Dept, WARNING: Hot surface. DA NGER: Risk of electrical shock, Refer to product instructions. 1A D•NGM The Engage Cable terminator cap must not be installed while power is connected. DANG15M 0ectfle shock hazard, The DC conductors of this photovoltaic systern are ungrounded and may be energized. WARNING: Always de-energize the AC branch circuit before servicing. Never disconnect the DO connectors under load. Disconnect DC connections first, then disconnect AC con- nections. A I WARNING: If the AC cable on the microinverter is damaged, do not install the unit. DANGER! This indicates a hazardous situation, wNich if not avoided, will result in death or serious injury� WARNINGI This indicates a Situation where failure to follow instructions may be a safety hazard or cause equipment malfunction. Use extreme caution and follow instructions WARNING! This indicates a situation where failure to follow instructions may result in burn injury, M NOTE This indicates information particularly important for I optimal system operation. Follow instructions closely.--.] WA� I - WMMUNS rMs of the PV module with the allowable input voltage range of M th Eaphase Micrdjnverter� 16-48V. ix ,{ury .PEA ink #Y 25 years limar perfomaom guarantee ! extension of prodixt wwnmqto ! il.. • 9 } ! ! ♦ in the coumm, of Common fn the to has been extended p1 !t t. ix ,{ury .PEA ink #Y 25 years limar perfomaom guarantee ! extension of prodixt wwnmqto ! il.. • 9 } ! ! ♦ in the coumm, of Common fn the to has been extended p1 !t ix ,{ury .PEA ink #Y 25 years limar perfomaom guarantee ! extension of prodixt wwnmqto ! il.. • 9 } ! ! ♦ in the coumm, of Common fn the to has been extended p1 Su n mo dul e ; 4, ""mus m on o Yp (Pj ttae�try x�afsY/^ it }. .0 R'.. ICS s R >x a _ Y Yp (Pj ttae�try x�afsY/^ it }. .0 R'.. ICS s a _ Y i3 VERSM 25 FRAME ## O.- :. modultintheodendedfbnSe Y Y , rveP�to atixd+e ftx h l+swp CIM Law iWaftmPeredwM ARC ,eat Ridge Building Dept, Bich Plan c hecker V . ry t , a �# WAF Wiom Southern Californiw 1276 E. Colorado Blvd, Suite 201 Pasadena, California 91106 626.793.7438 626.793.7439 fax Renusol America Rep: John Hudson 201 17 Street NW, Suite Atlanta, GA 30363 Whea I t Ridge Building Dept, a t, e -. 1 - .3/ ;&tJ Signed4AW Plan checker Taylor & Syfan Consulting Engineers, Inc. Engineer of Record: Michelle McCovey-Good, P.E. Project Engineer: Amy Ransom Project Manager: Joel 3. Neal, P.E., LEED ApBDIC T&S Job No. 12243 B This document is confidential and for internal use only. The use of this document and the information contained therein shall be restricted to the scope of work outlined in the signed contract. Other use or publication thereof is expressly prohibited, Reproduction or distribution by any method, in whole or in part, outside of the agreed scope and non-disclosure agreement is prohibited. Title to this document remains with Taylor & Syfan without pr(Zfud/ce- @ 2012 Taylor & Sytan Consulting Engineers, Inc. 11-5-12 8SUNIO-LY15"IRAD idft ASCE 7-05, Exposure Category B, Occupancy It muwffil�-� Single Span WindFactors E = B Exposure Category Kz = '1 Exposure Category Coeftiant Exposure 8 Occupancy 11 muwffil�-� Single Span WindFactors E = B Exposure Category Kz = 0,70 Exposure Category Coeftiant i = 1,00 Importance Factor (Wind Loads) Kd = 0,85 Wind Ditecthnafi ty' Factor Z = 30M He## above ground (ft) Kzt - 1,00 topography Factor V -- varies 3-second gust wind speed 1't Factors Ce I M Exposure Category Factor Ct 110 Thennal Factor i = 1,t fmportance Factor (Snmy) Panel Factom Max, Panel Area is ft- Max, Panel Wt. 46 lbs stand;ffs (no �pkes on 6afflever portions) Mamum datkotion #mt L1120 Saw Land �2 as R u " �r+ iFY u ' 0 a� �o C 75 o 41 0 0 R C + 0 cs c tj a, ar 0 0 .0 a + ° ca `vim [ 0+ Rt 0 0 M = W p Z 0 1 4 M - Gi ro m q 0 C ti v t = M E 0.. m 0 R u " �r+ iFY u ' I Me I Nd 4 JWNO u idao suolps to 8 75 0 .5 - CL tt3 4,J 0 0 > w kA 0. to Q 4 M C o 40, 42 E 0 S= w UO > -6 0 0.. 4 - - 2 j = 41 to u CU m C (U 41 "avow c) J 0 ra Kit Kj0068:x2Lx 2. Clean sawdust, and fill hole with sealant. Install AL shoe to roof by using 5116 lag bolt (Use GE 1200 Construction Silicon Sealant • Equivalent) 5. Install AL rail to V foot to the specific orientation. Then, tighten AL hex cap and flange nut to 20 lbs-ft torque. APPROV D Subject to Field I aw 4. Using the 318 inch flange bolt (supplied with AL I" foot) attach to the top of the standoff. awl mjff� IR 3. Place AL standoff on shoe threads and tighten by hand then • wrench. Use 15 lbs-ft. nominal 1 4 1A 1 T ' T' T' MWAMM" Iw 2. Mount the "C" bracket instead of foot, using the Hex Nut. The "C" bracket can be used to mount a variety • rails and other rooftop equipment. to Field Inspections Wheat Ridge Building Dept, EZ Roof Mount Installation 0 Su Mod 2014 ocumaltO 2014-KI006ge 1 Date: S Plan checker, OR Drill Sit for tag bolt, 7132 inch diameter. installation. P , A 80071 or equavalent). 1116 inch Hex nut. 1200 construction sealant or equavelent). APPROVED Su�ject to Field Inspections he Ridge Building Dept. EZ Roof Mount �nstallation 0 SunModo 2014 D cument I 01y1 68c Date, ff Signed 9 Plan checker AL Shoe A20065 5!16,X4 Stainless Steel Lag AL Flex Cap Sealing Washer Bolt 0066 -001 and — BKI CI000 -0th1 B15015-002 *Note that variants are Black, extra height, extra length, and other options. Wheat Ridge Building Dept, Date, ignd Plan checker Eaton Electrical, Inc, 1000 Cherringlon Parkway Moon Township, PA 15108 Tel: 1-8W-525-2000 www-estoneleacirical,com For a complete list of utility approvals visit www.eatonelectricxom To request an approval ernail: utilityapprovais*eatonelectric.com ff ('"Sm AM flights Resemad g", Printed in USA Pub No, PADOSMIE P I September 20% m M t"n in e u N" Cu s to •:` of • • Subject Field Inspections Wheat Ridge Building Dept. Date, ,r Signed' Plan checker Three lugs der k iL -IMT - Internal Hex - coal Hex KSM -INT - Internet Hex (set of 4 1 °er) I� f, t► f wit a Three lugs der k iL -IMT - Internal Hex - coal Hex KSM -INT - Internet Hex (set of 4 1 °er) I� 104-0404-000077-003 nc - 411 Pinhtr, Reserved Module frames like those shown here may have a ridge or lip on the bottom edge of the frame that would prevent the WEEB, teeth from fully embedding. 91 91 W I I 1- 10 104-0404�000077-003 the I t Ridge Building Dept, Burndy I. 2006-20129 - All Rights Re, e Page 3 of 13 N t - .3 Signed: 4- l cheCker WEEB teeth from properly penetrating the module frame. This type • frame is not compatible with the WEEB. WE E B te eth f ro m p �o pe rly p'e r odule e. This type of frame is not compatible with the ro-W APPROVED Subject to Field Inspections Use WEEB-CCR t(I bond solar modules to ri mounting rail. Y I ILIZING WEEB-CCR m H AVI. i I i I nr-ltLqlr-jm RAMORM T- Page 6 of 13 SEEM -3• H Place a WEEB-CCR on the HatiCon Soler Rail Take a Mid-Clamp AK HD Assembly with the tabs down engaging the rail and clip it onto the rail over the WEEB-CC R C Install *" and mid clamp asse in p , • • not tig hardware yet. • r • �s � w e 1 "04-000076 - 00 5 r 2006 -2011 Pag 8 of 14 slage%fa C"##C WEEBs are for SINGLE USE ONLY! Do not torque fasteners down if position of solar modules is not finalized. Only sligh tighten fasteners to keep modules in place. t 1 i M Assemble end clamp to manufaCturers SPeCifiCation, APPROVED Subject to Field Inspections 104-0404-000077-003 Wheat, Ridge 1301ding Dept, eurndy L.L.G. 2006-20120 - AH Rig s Rese Page 9 of 13 bate: Signed - ___ �_ Plan checker H WEEB-CC N ot e - When module which contacts the same WEEB , as th will e nsur e th AE Wheat Ridge Building Dep rndy LL C, 2006-20120 - All Righ Page 10 of 1 3 61 k�,,�r Plan chec X DENOTES PLACES TO INST X DENOTES PLACES TO INSTALL WEEE3-CCR v w &no saw 1 %00 0 -- w var *A*V %M 0 w 4 amw "m u M8 N IMEEMM M8 Flat Washer Install M8 T-bolt at desired position and slip WEEB-1 5.8 over the bolt A, . Wheat Ridge Building Dept 'Uate: - : d-IP< Si g ned)-116 — / °-- an checker "PTIM am Lay in equipment ground conductor 2nd torque terminal screw • 7 ft-lb / 10 N-m. Note; See the last page of this manual for a!, WEEB Bonding Jumper 8.0 locations. 101MCMUMM CL - C - 7ZIT i 6ZANY 44 Page 12 of 14 G und rwl#- APPROVED Subject to Field Inspections Date.: • Use two (2) WEEBLug-15.8s and a short section of 6 Gauge EGC wire to create a splice 2) Torque M8 T-bolt hardware 12 ft-lb / 16.3 N-rn using general purpose anti-seize compound on threads. Tighten the terminal screw with 7ft-lbs 110 N-m of torque M M 1) Install HatiCon Solar Splice Bar according to manufacturers instructions 3) Lay in • Gauge EGC VVire. Leave slack in 6 Gauge EGC in case of splice expar Sl e t to Field Wheat Ridge Building D. 10 4-0404-000077-0�5 ) ate: Burndy LLC. 2006-2012e,- All Ri hts Re9ery Page 13 of 13 '3igrje ,d Plan checker ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE ,el/ 13a Inspection Type: rkJS1r1�TsS�'7Z3e� Job Address: car r Permit Number: ❑ No one available for inspection: Time AM /PM Re- Inspection required: Yes i No/ "When corrections have been made; oaz for re-ins , action at 303-234-5,933 Date:_, 4 / Inspector: ! I �< .a A f okwi 4,'~~_ >.~',~.J!!.I,~.U,.~\.,~.~~,..,~4)iJA:':'1 t J..~~J.~"".P!'ljlll!!Il!r, ..L.llill\ll.~il'U.II1';1J!ii!~"'. ",.~.'H.I!l:.)ll!Il~J,Jj"....,~" ~fLrnl:IQ.,.- .Il!J!!,:n~ City of Wheat Ridge Residential Fence PERMIT - 070329 PERMIT NO: JOB ADDRESS: DESCRIPTION: 070329 4535 FIELD ST 6' privacy fence - cedar ISSUED: EXPIRES: 04/17/2007 10/14/2007 . ** CONTACTS **. owner 303/249-8151 , Anthony Miller .. PARCEL INFO ZONE CODE: SUBDIVISION: .. R-2 UA USE: BLOCK/LOT#: R-3 0/ Permit Fee Plan Review Fee Total Valuation Use Tax ** TOTAL ** ESTIMATED FEES 108.30 70.40 .00 44.55 223.25 PROJECT VALUATION: 2,475.00 .. FEE SUMMARY.. ta.~~z4 , , PIaA Note: pwncr I contractor Is responsible fotlocatlng property Unes and constructina imn~t~ ~t.".^"tn", tA tM 'approVed pliii8iid required development standards. The City Is not responsible for inaccurate information IUbmittcd within the plan set and any CODStructiOll cmml rcsuIting from inaccurate Information. Comments: I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allega 'ons made are accura that I have read and agree to abide by all conditions printed on this application and h t I ass 11 re ne 11it compliance with the Wheat Ridge Building Code (I.B.C) and all other applic e e Ordi is permit. plans subject to field inspection. 4"f?~~7 date 1. This permit was issued in accordance with the provisions set forth ln your application and is subject to the laws of the ~tate of ColoradO and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at_the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have.been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be dOne that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject to field inspections. INSPBCTION RBQUBST LINB. (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) MINOR APP TION Property Owner: /-:;/) ~1.7' zr 2r:'/J'1t /~ Ie" /',0-~/'? Property Address: q'5 3'.9 ,/7r47:'7/ n-A.,q. /,;,/'(//(31/7" Contractor License No.: cJi!"2?3;J Company: Building Permit Number: Date: I PLAN # Phone: ~'275",;l7't- 8/S'/ ~ Phone:~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I Bui/din" Dept. Valuation Figure: $ I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge BUildJ.'n9. C. ode (I B.C) an~.a.1 0 ef applicable Wheat Ridge Ordinances, for work unde: this ~rr:nit. P s s~.t;~. ~.. field Inspection. . IOWNERllCONTRAcrORI SIGNED ~ . fJ}!;;.{ t DATE .v~/6 ,t?;' VaIue:$ -?<I-=?5""- Permit Fee:$ Plan Review Fee:$ Use Tax:$ TotaI:$ (OWNER)(CONTRACTOR):PRINTED DATE Use of Space (description): Description of work: (p f rl.'Vu.cO 'f?f~....e..e. -' c..e--aA.A...J Sq, Fl. added BUILDING DEPARTMENT USE ONLY SIC: Sq,Ft.: ONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: ~ IE tC IH\.71E [Ol Approval: PUBLIC WORKS COMMENTS: APR 1 6 2007 Approval: --------------- IRE DEPARTMENT COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Eiectricai License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approvai: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit may be" acquired for a fee of one-half the amount normally required, Jjrovided no changes have been orwill be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1)year. If changes have been or if suspension orabandonmentexceeds one (1) year, full fees shall be paid fora new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty.four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject to field inspections. Chief Building Official go?' 1 /"<( ,fV-,,/{'/,// L." t' , -tf- ,dr',. I~b'> - ~Jp~-i I~ S I I e?' I /r /Prrl/ ..0'n( 702 56' (11!I"'fj ~Y'(' t:dC , ..v , _"?_ -..~ - . I . -#- -.p;' .- fi) '" j. !lDVX' -G....k /16 1'- -IJ , 3)' ~ j 16: T I ,-> -.. 1" /'I' <{'/' -IP' S'Il 5<' J6i0A 'bs ..-"'?(":/r...-- i ~ <: (:::). ;J.'f'- ~/" L"!t'kr /' ~ f".-rnf 5d~/2 :y o 1 S. ~<J :1' ~.s>....o >>. ;:'<;-~',$'~~.~-$><;- ,II> ;;#.~'io'=' ,<S' ~6' "," 1-.0 <F ~... ","'~ Q ~",<;f~$' ~.tj.~o<;-' ,,~.# # ;:,.o~ $-v.."o,#, _ . .umm__'O!rt~"'Z.l'.~O '~"""f~'I>...o" ..~#' . &~~~.f:~'" ..'" ~ rekl >l I~"# ~<P:~:t \,,0 6' 'I<.~",#.~~<$' -~;'~~)>~t~~;'l~ -- "v<;-"'~.s>G~.~ ~~ .",11 ,!'<> 4> '" Sktl!f t(~?5 hel/ 5J- :S/ Ie fJ ,/0-/1 0:<'/-;: 2.- iE3uildingPermit CITY OF WHEAT RIDGE 7500 West29TII Avenue Wheatridge, CO 80033 303-235-2855 Permit Number 19622 12/28/2005 Inspection Line 3D3-234-5833 Residential Roofing PROPERTY 4535 Field 8t Unit: (303) 249-8151 OWNER: Tony Miller I)escription Tear off 2 layers existing, Install underlayment, flashing and new Landmark tri-laminated shingle roof system IFEES IFees IUse Tax IPermit Fee ITotal Fees I ICONTRACTORS IName ITiley RoofinQ Inc, I IDue 1$71,71 1$126.50 1$198.21 I I I License # 121395 I IPaid 1$71,71 1$126.50 1$198.21 I I IPhone 1000426-7370 Documents from thli'. manulacftlrer shall be onsite for final roof inspection winch ~pecify oftng matl/riale have been installeii to meet l~O MPHthN!(j.Sficond Wind gustc--IBC . Units: Stories: Sq Feet: Oc(:upancy: Walls: Roof: Ihereby certify that tbesetbaek distances proposed by this pennitapplit'lltion areaceuratc; IInd do not violate IIpplltllbleol'dInIlDces, rules orregulatioIlliofthe,Cityof \Vheat Ridge or covenants. easements or restrictions ofreconl; that all measurements shown, and allegations made are accurate; thatI have read anda~ to abide,by .~ ,tin... on'" ""'"lIon. ond ......"nm,fnU ,~,no"bllily ro< <om,...." wUb.., Wh," RId" BnUdin, Cod, Q"B,C,) "d.U n"" ."U"h1, Whdordiriancrthispennit. ..... ". . . ....., "2-/?KA5"' . (OWNER){CONTRAC SiGNED DATE This pennitwas issued inaceordimce with the provi5lons !let forth in yuur application and is subject to the laws of the State of Colorado and to the Zoning RegulatiolL'l and Buildb:ig Code ufWheat Ridge, Colorado or any otb<< applicable ordinances oCthe City. Every pennlt issued shall become invalid unleSs the work on the site authorized by such permit is commenced witbinI80 days after Its IsSuance, or if the work authorized on the site bysucb permit b suspended or abandoned far II period of 180 days after the time of work is commenced. 'Uthls penult expIffl, II 'new peiinltmay be IIcqulmfror II fee of one-half the amount normally requh'ed, provided ~ochIlDgeshaveb~orwillbemade in the originalplansllnd specifieatioDs and any suspension or abandonment has not exceeded one (1) year. If changes are made or ifsuspeusion or abandOnment exceeds one (I) year, fun fees shaUbe paid for a new penuit. d specifications shan not be construed to be a penuit for, nor an approval of,any violatiou of the law, rule or regulation. . SIGNED DATE Page I of! December 28,2005 I I I! 1/ I- I I I I '" '"- "\ ~J1 -5:? i~?lJj;qrJJ 3"'f1 -, <,.12: ,_<I "':::':1 o Building Permit CITY OF WHEAT RIDGE 7500 West 29TIl Avenue Wheatridge, CO 80033 303-235-2855 Permit Number 19416 10/2612005 Inspection Line 303-234-5933 Residential Mechanical PROPERTY 4135 Field St Unit: (303) 249-8151 OWNER: Tony Miller Description Replacing 110,000 BTU furnace wi high efficiency 70,000 BTU furnace: Adding 2 1/2 ton AC IFEES IFees IUse Tax IPermit Fee ITotai Fees I ICONTRACTORS IName ICoolinQ & HeatinQ of Colorado I IDue 1$102.60 1$162,90 1$265,50 I I 1 License # 121118 1 IPaid 1$102,60 1$162.90 1$265,50 I I IPhone 1000 227-9284 7Qfp CitvofWheat Ridae PRESCRIPTIVE ENERGY CODl; BOILERS I FURNACES AMINIMIJM OF 900/, AFUE ~If:~~i~!~~m;~~~~r~~~Eg!p~~~:~~~~~~R R.21 WALLS . R-38 CEILINGS . R-19 CRAWLSPACES "/ Units: Occupancy: Walls: Roof: Stories: Sq Feet: I hueby certify that the setback distances proposed bythispennit application lire'accurate, anddo not:vlobte applieableordinances. ruleS orregillationsoftllliCityof Wheat Ridge or covenants, eallemcnts or restrictions orrecordj that allmeasnrements shown, and allegationsmade lire accurate; that I havcread and agree to abide by all conditions prlnted on this application, and that! assumefull responsibility for compliance with the Wheat Ridge Building Code (V.B.C.) and all otJ.ler applicable W.h~. 'd.. dinances, for work under thls pennit. .' . .', ........ .'. .' '.' .... -, ... .... ..... .... .' ........... . ..... /." I c--'. . . .~" . / O!:J.~/))(~ . (OWNER)(CONTRACTOR)" . . . ... . '.' .... . SIGNED DATE This penult was issued in accordance with the provisions set forth in yourapplieation and is subject to the laws ofthe State of Colorado and to the Zoning Regulations and Bulldlng Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This penult shall expire If(A) the work authorized is not commenced within sixty (60) daysfromissue date or (B) the building anthorized is suspended .or abandoned fora pedodof120days. If this penUlt expires, a new permit n.aybe acquired for a fee of on~halfthe amount normally required, provided no changes have been or will be made In the: original plans and specifications and any susp~nsionorabandonment has not excuded one (1) year. If changes are made or ifSll.'lpensionor abandonment e;l;ceeds one (1) year, full fees shall be paid for a new penuit. 4 No work of any manner shall be done that wlllchimge the natural flow of water causing a drainage problem. S Contractor shall'notify the Building Inspector twenty-four (2.4) hOIml in advance for all inspections and shall receive written approval on inspectioneard before, proceeding with successive phascs of the job. 6 gInspector SIGNED DATE Page 1 ofl' ChlefB Wednesday, October 26, 2005 "-~' ~H'~r "/ ~ 0 - " U M CO( OR "SP COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) APPLICATION Building Permit Number: Date: Property Owner:, Dl\ ~ iY\ i \ I (> ...- Property Address: Y5';,s 1=-( 1'\<1 s+ Contractor License No,: ;) 1\\ 'D Company: (\>O\i"s, -., 0?~'ltt(\:\lo Phone: )((C; - 'il <;'/ Phone: 3. 0'3 ' d:;) '7 /;2 y</ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I Buildino Dellt. Valuation Figure: $ I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. (OWNER}(CONTRACTOR): sIG::-f;Wh/LC _~ DATE /() /J tit) (OWNER)(CONTRACTOR):PRINTED ~'S~y..o " DATE Value:$ '5700. Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ Use of Space (description): Description of work: Mp~'~l~~ "'S \~o,evot;\-l.u blt(Ac.(J! i\ctd "'5 'd'h r Oi" Il C- Sq, Ft. added U;~k I-\;~l- Ebb" 70, bCD t;tz._+VC^ c, <J2 ~ONING COMMENTS: Approval: Zoning: BUILDING DEPARTMENT USE ONLY SIC: Sq,Ft: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: IRE DEPARTMENT COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City, (2) This permit shall expire if (A) the work authorized is not commenced within sixty (90) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject to field inspections. Chief Building Official COMMUNITY DEVELOPMENT DEPARThfENT BvaPING INSPECTION LINE .303-Z34-m3 CITY OF WHEAT RIDGE 7500 WEST 19TH A VENm WHEAT RIDGE. CO 80%15 - (303-135-1855) MPUGfJ70N Property Own_( \ l~ \'\\ \ \\Kf, " Property Addr_." J'\ ~ ;I=ui.\rt. & ~1\J.t+ ContraCtOl Lic_lI$_ NO~0 ~ ~ ~ COIDJWlY \\\.eu~. . ~ c. Building Ponnit Number D....: Pbone : S' j-/'1 r:,!ti Pbon-:J-iU[,..731O OWNEItICONTRACTOR 51GN'Al'UU O. Ul'fDEUTAl'fDING AND A.~ Construction Valuc:$0 , Permit Fee:S Plan Review Fcc:S Use Tax:S Total:S I "'"by ccnify tbat the ._distlll""',..,.,..u by lhispamltapplicali......_, NUS do ao(vtOltle applicable ordinmcea, ruW orrepladou oldie Ci~ ofWhcat &idee or 'covenants, easemmllorratricrions ofree.onl; tbal:a1\ meulD'llMDt5~and a11cpDoni made vt: ac~te; that I haV'e Mad and qrec to Ibidt by all conditions prin10d on WI IfPlU:.ation and that I assume ft.Il1 respoasibility tor toIf1)liancc with du: Whcll Ridp Build... Code (IJ,B,C)1Ild III olller oppl Ie Wheat Rid" 0._.. for_k Ullda' cblipennit. ~ 7 (OWNERXCOtmlACTOR.) -- ,.... 'I ~ \~ ~ ,-.'\~~ \J(\M~~I V\QW 2XW'O\..~K. \il \C\\iv--U\,~ :'::lM'IC-tV DESCRIPTION:'-----\eX:IX c.. ~~~ vm'\- 0'-l~' BUILDING DEPARTMENT USE ONLY SIC: Sq.FI.: ZOtUNG co.......,.: Approval: Zoning: BUILDING CoM"'NT" Approval: PuKlC *,,0 COMIIRNTS; Approval: Occupllllcy: Walls: Roof: Stories: Rc:sidcntiol Unit>: Electrical License No: CompllllY: Plumbinll Liccoe No: Company: Mechanical License No: Company: Expinlloo Dale: Approval: Eltpiration Da1c: Approval: Expiration Dare: Approval: (1) Tbilpcrmk ....MNcdiD~ wiIJIM"..nacm m.bdt.iayca~- il~to"lnIs at1lal: SIlk olCokadoalld to WI zo.iItc bpII_....B_CodIIcl-........~"'..y.....~.,Ii,""'_otI...Cily' (2) TIais~tllllllapirl il(A)dle~~isllOt ~._~.... sb.ty(60)."... illueUltor(JI)" W1dillc~1,1IIIpDlkd or ~1ar..pMiod.ofl20__ (') Ita pennil.,aa.. ..-J*IIlit..,. "KQ~ 1M I fee ot~IK....c..-Dy ~ plClWk4l1ll ",,-,,).aIvt'" or wiD be aIIda ill lbIllriP-1p1&u-~" dllay~orl'.' f..IIIlCctteeM4...(l))'CII'.lfcUal........Ofj{s~tltl\rnd wst ~ au (1) JCIf. fIlJI fer:ldIID bep.Utl tlr&llNplnlit. (A) No ~ oIl11Y __PaJl." dDIIe &laaI: wiD cIlaqc ~ 1llUIl Row oIwa11r -ill'.... plQblla. ~) CodacWIblll...lk:BWIdiq~CwcDlY....(Z4)bounu.ad.YI2lCCfar.u~ud.w ~ve.......~alCllll. iDlptcdDac.araMfl:R proceedia&widllWlCC.aw",ol...joIt. (Ii) The if;1\aaee Dl.,...n or 1K JppOVIl afm.._ _II*~ ~ DOt be COfodad to be.. pmail fer. 1lOI' UIo ~ of. KlY Ifi01I,Id of die pC'Ovisiouof_bID1ctia(oodllCll'lA'JodKr~"", MOI'....IIIaIlaa. Cbief Building IDBpeclor .~Q'q 175.: <:\WJ<: ll.Jl'\ol lS8l$:l!i:~:X(>.:l I'ld ~ ~I~ld DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: 7940 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 10/9/98 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Property Address: 4535 FIELD ST Contractor License No,: 18505 Company: BARTELS HEATING & AlC OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Phone: 3034225892 Phone: 422-3589 Construction Value: Permit Fee: Plan Review Fee: Use Tax: $1,700,00 $55,00 $0,00 $25,50 $80,50 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (V. B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED Total: DATE Use: Description: Install replacement furnace. 75,000 BTU BUILDING DEPARTMENT USE ONLY _EFf1im~~memd Approval: Zoning: SIC: $q, Ft.: ~ Approval: -- ~ Approval: Occupancy: Roof: Stories: Walls: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the/'ob. (6) The issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. J1.1)/1 (f(~'rJ.4A- if Chief Buildin Inspector t , THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: e.o.f)\ p igll.o.- PropertyAddress: 4535 field &to Phone:303-4dJ-S6QJ.. Contractor License No,: \ 'D 50 ~ Company: ~o.\"\-{l~ l-\eQtl:'rg G.nd~G Phone: ~Ob- !.tn- 358"f OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: I -, 00 '" Permit Fee: 55.DO Use Tax: J, S. ~O Total: 8 O. 50 I hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants. easements or restrictions of record: that aU measurements shown. and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application. and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permrt. (OWNER)(CONTRACTOR) SIGNED~ a )o~Ae0 DATE /6 'lo-C(-g Description: ;:(,nsttl.ll n'fkH.etnent~fl'\llU) .5,000 tofU. BUILDING DEPARTMENT USE ONLY "::J')HH"~'~""'11 l!'" Approval : Zoning: .:':..LI.' ,,~;l" 'l-.II''''~I\'~r' Approval: ~J . 6.1.J~;t.!~~"w).J.il!' Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company Plumbing License No ' Company: Mechanical License No : Company: Expiration Date: Approval: -:! PlansR!Clu!tlld;:::l Expiration Date: Approval: ..I ,Pl'-lis. Required -I Expiration Date: Approval: :JI iP~1DAII!- 11) (2) (3) This permit was ISSUed In accordance With the proVisions set forth in yopur applicatIon and IS sublect 10 the laws of the State of Colorado and to the Zoning RegulatIons and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City ThiS permit shall expire If (A) the work authonzed IS not commenced Within SIXty (60) days from Issue date or (B) the bUilding authorized is suspended or abandoned for a penod of 120 days. If this permit expires. a new permit may be acquired for a fee of one-half the amount normally required. prOVIded no changes have been or will be made in the ongmal plans and Specifications and any suspenSion or abandonment has not exceeded one (1) year. If changes are made or If suspenSion or abandonment exceeds one (1) year, full fees shall be paid for a new permIt No worK of any manner shall be done that Will change the natural flow of water causing a drainage problem Contractor shall notify the Building Inspector twenty-four (24) hours In advance tor alllnspectJons and shall receive wntten approval on inspection card before proceedllng WIth successIVe phases of the Job The Issuance of a permit or the approval of drawings and specifications Shall not be construeo 10 be a permit for. nor an approval of. any Violation of the provisions 01 the bUilding codes or any other ordinance. law. rule or regulation (4) (5) (6) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION