HomeMy WebLinkAbout4753-4755 Holland StreetCERTIFICATE OF COMPLETION
City of Wheat Ridge
7500 W 29th Ave
Wheat Ridge CO 80033
Permit# 091747 Issued: 09/10/09
Stipulations: Repair Structure from Storm Damage
This certificate verifies that the building constructed and/
or the use proposed of the building and/or premises, under
the above permit number and on property described below,
does comply with the Wheat Ridge Building Code and
development standards of the zone district in which it is
located and may be occupied. All other licensing
requirements for the City must be met.
Site Address: 4753-55 HOLLAND ST
Parcel Number: U0058
Owner: Sam Lombardi
Contractor: Roger Peterson
PHI Homes Inc.
11953 W. 56th Cir
Arvada, CO 80002
For the Following Purpose: Residential Remodel
Coyer Editions NO change shall be made in the USE of
2003 ICC/2005 NEC this building without prior notice
2003 ICC/2002 NEC and a new Certificate of Completion
1997 UBC/2002 NEC from the City of Wheat Ridge.
Sprinkler,,System
Inspector Zoning Administrator
CER-TIFICATE MUST BE POSTED BY FRONT DOOR OF
COMMERCIAL OCCUPANCIES
f 09/12/09 10:36:20 City of Wheat Ridge Page 1
bp70l-ls PERMIT INFORMATION -091747 mmackey
PERMIT INFORMATION:
Permit: 091747
Permit Type: Residential Remodel
Permit Dt: 08/28/2009
Expires: 02/24/2010
Address: 4753-55 HOLLAND ST
Parcel Cd: U0058
OWNER: Sam Lombardi
Address:
City/St/Zip:
LAND PARCEL INFORMATION:
Zone Cd: Unassigned
DU: 0
SetBacks-Front:
0.0
Funct Use: Unassigned
Last Zone Dt:
Left:
0.0
Subdivision: Unassigned
Annex Dt:
Right:
0.0
Cant Type: Miscellaneous
Lot:
Block No: 0 Back:
0.0
Legal:
JOB DESCRIPTION: Rpr struct from fallen tree. Roof/Drywall/paint/minor elec
FEES
QTY
DUE
PAID:
Permit Fee
18,900.00
399
.50
399
.50
Plan Review Fee
.00
259
.68
259
.68
Total Valuation
18,900.00
.00
.00
Use Tax
18,900.00
340
.20
-
340
.20
999
.38
999
.38
CONTACTS:
owner Sam Lombardi 3034228719
gc CL3 PHI Homes Inc. Roger Peterson 11953 W. 56th Cir Arvada, CO 80002 3034670076
SUB CLA Gill Electric Lawrence Gill 6000 W. 32nd Ave. Wheat Ridge, CO 80033 3032371483
GC CL1 PHI Homes Inc. Roger Peterson 11953 W. 56th Cir Arvada, CO 80002 3034670076
PERMIT CONDITIONS:
JS: Approved as submitted. Work shall comply with P.E. letter. Subject to field
inspections. Must comply with 2003 IRC, 2005 NEC, and all applicable City of
Wheat Ridge Municipal Codes.
APPROVALS:
REQUIRED INSPECTIONS STATUS:
PERMIT NOTES:
08/28/09 CREATED FROM APPL# 09-0268
INSPECTION INFORMATION:
4 TYPE
CONTR#
CALLED
CNCL
WHO
REQ DT
INS DT
STATUS
1 FRI
:Framing Rough Insp.
02-0791
08/28/09
no
CCI
08/31/09
08/31/09
COMPLETE
2 MID:
Midroof Insp.
02-0791
08/28/09
no
CCI
08/31/09
08/31/09
COMPLETE
4 ERI:
Electrical Rough Ins
02-2483
08/28/09
no
MV
08/31/09
08/31/09
COMPLETE
5 INS:
Insulation
02-0791
08/31/09
no
KC
09/01/09
09/01/09
COMPLETE
6 bfi:
EUilding Final Insp
02-0791
09/10/09
no
KC
09/10/09
09/10/09
COMPLETE
7 efi:
Electrical Final Ins
02-2483
09110109
no
KC
09/10/09
09/10/09
COMPLETE
8 rof:
ROO£ Inspection
02-0791
09/10/09
no
KC
09/10/09
09/10/09
COMPLETE
INSPECTION RECORD
Occupancy/Type
INSPECTION LINE: (303) 234 -5933
Inspections will not be made unless this card is posted on the building site
Call by 3:00 PM to receive inspection the following business day.
11
l
INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS J OB
FOUNDATION INSPECTIONS
DATE
INSPECTOR
INITIALS
COMMENTS:
Footings /Caissons
cp �; `�y
Stemwall / (CEG) Concrete
Encased Ground
-b
Reinforcing or Monolithic
¢ /o E'.{'
/!C
Weatherproof / French Drain
L
- '1
Sewer Service Lines
Water Service Lines
-
POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED
CONCRETE SLAB FLOOR
Electrical (Underground)
*NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A.
CERTIFICATE OF OCCUPANCY. is ISSUED. FINAL INSPECTION BY THE BUILDING. DIVISION DOES. NOT CONSTITUTE AUTHORIZATION
Plumbing (Underground)
Heating (Underground)
DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED
ROUGHS
Sheathing
/p 9q
Lath / Wall tie
cp �; `�y
Mid -Roof
-b
Electrical' Service
¢ /o E'.{'
/!C
Rough Electric
L
- '1
Rough Plumbing
Gas Piping
:INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS
SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS.
Rough Mechanical
*NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A.
CERTIFICATE OF OCCUPANCY. is ISSUED. FINAL INSPECTION BY THE BUILDING. DIVISION DOES. NOT CONSTITUTE AUTHORIZATION
ABOVE INSPEARONS TO BE SIGNED PRIOR TO PROCEEDING
framing
- ( -04 1
/p 9q
Insulatiori'
cp �; `�y
Drywall Screw
FINALS
Electrical
/p 9q
`Plumbing
Mechanical
.Roof
¢ /o E'.{'
/!C
Building Final
L
- '1
Fire Department
R.O.W S Drainage
:INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS
SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS.
'.Parking & Landscaping.
*NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A.
CERTIFICATE OF OCCUPANCY. is ISSUED. FINAL INSPECTION BY THE BUILDING. DIVISION DOES. NOT CONSTITUTE AUTHORIZATION
OCCUPANCY NOT 'PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED
PROTECT THIS CARD FROM THE WEATHER
♦ i CITY OF WHEAT RIDGE
� j Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office • (303) 235 -2857 Fax
INSPECTION NOTICE
Inspection Type: /3t / �!� a�2', sir ✓�G d �c kG
Job Address: 57
Permit Number: 0717nl
❑ No one available for inspection: Time 3 "105 AM /PM
Re- Inspection required: Yes 9'
* When corrections have been made, call for re- inspection at 303 - 2345933
Date: clllole y Inspector: m
f
DO NOT REMOVE THIS NOTICE
♦ i CITY OF WHEAT RIDGE
r Building Inspection Division
1 (303) 234 -5933 Inspection line
(303) 235 -2855 Office • (303) 235 -2857 Fax
INSPECTION NOTICE
Inspection Type: t
Job Address: '/759 11e1111au? SP`
Permit Number: 6
E
4
❑ No one available for inspection: Time 7 `rte AM /PM
Re- Inspection required: No
'When corrections have been made, call for re inspection at 303 - 234 - 5933
Date: <✓�i Inspector: t°
DO NOT REMOVE THIS NOTICE
♦ i CITY OF WHEAT RIDGE
Building Inspection Division
I (303) 234 -5933 Inspection line
(303) 235 -2855 Office • (303) 235 -2857 Fax
INSPECTION NOTICE
Inspection Type: '511 - ✓u
Job Address: uif 3 -^ flnff,�'
Permit Number: 04
f , "A
Gm l
❑ No one available for inspection ` Time ft af7 �M
Re- Inspection required: Yes 00
"When corrections have been made, call for re- inspection at 303 - 234 -5933,
ff e } S1 P
Date: , �, Inspector: /�, � j�e , P
DO NOT REMOVE THIS NOTICE
♦ i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 inspection line
(303) 235-2855 Office • (303) 235-2857 Fax
INSPECTION NOTICE
Inspection Type: C. "
Job Address: °a S~ Ys° r~ 10~r~u7
Permit Number:
❑ No one available for inspectior
Re-Inspection required: Yes 9
When corrections have been made
Dater Inspector:
DO NOT REMOV
me AM/PM
for re-Inspection at 303-234-5933
NOTICE
City of Wheat Ridge
Residential Remodel PERMIT - 091747
]!?;Ir
PERMIT NO: 091747 ISSUED: `08/28/2009
JOB ADDRESS: 4753-55 HOLLAND ST EXPIRES: 02/24/2010
DESCRIPTION: Rpr struct.. from fallen tree..Roof/Drywall/paint/minor elec..
CONTACTS-.***
owner 303/422-8719 Sam Lombardi
gc 303/467-0076 Roger Peterson '.02-0791 PHI Homes Inc.
SUE 303/237-1483 Lawrence Gill 0.2-2483 Gill Electric
* * PARCEL INFO
ZONE CODE: UA: `USE: :UA
SUBDIVISION: UA BLOCK/LOT#: 0./.
**`FEE SUMMARY .:ESTIMATED PROJECT VALUATION: 18,900.00
FEES ,+4
Permit Fee 399.50-)a J{. G
Plan Review Fee 259.68 -v--74s
Total Valuation .00
Use Tax 340.20
TOTAL 999.38
Conditions:
JS:Approved 'as submitted. Work ;shall :comply with P.E. letter. Subject to field
inspections.: Must comply. with 2003 IRC, 2005 NEC,:. and all.. applicable City, of
Wheat Ridge: Municipal codes..
`f,.
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable
ordinances, rules Jir regulations of th?City of Wheat Ridge. or covenants, easements or restrictions of record; that all
measurements.,sho3q and a1legationsi, de are accurate; that I have read and agree to abide by all conditions printed on this
application a,d'" hat I agsume full egpgngibility for compliance with the Wheat Ridge Building Code.(I.B.C) and all other..
applicable0rya Meat RidgeP rdimance for work undeF this permit. Plans subject to field inspection.
Signature oI ontractoiY%owner date
f
1. This p` it was issued in accordance with the provisions. set forth in your application and is subject to the laws of the
-State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other 'applicable
ordinances of the city..
2. This permit shall.. expire 180 days from the issue date. Requests for an extension must be received prior to expiration
date. An extension may be granted at the.. discretion of the Building official_
3. If. this permit expires, a new :permit may be. acquired for a fee of one-half the amount normally required, provided no
changes have. been or will be made in the original.plans and specifications and. any suspension or abandonment has not
exceeded one (1) year. If `changes have been or if.: suspension: or. abandonment exceeds one (1) year,.. full fees shall
be paid for a new permit.
4. No work of any manner shall be done that will change the natural flow of water causing a drainage 'problem.
5. Contractor: shall notify . the Building Inspector twenty-.four (24):. hours in advance for.: all inspections and shall receive.:.
Written approval on. inspection card before proceeding with successive phases of the job.
6. The issuance: of a permit or the approval of drawings and specifications. shall not be construed to be apermit for, nor
an approval. of, any violation of the provisions of the. building. codes or any other ordinance,. law, rule or. regulation.
All plan revi i ject to field inspections.
Signature bf h e uilding official date
INSPECT N REQUEST 'LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855
REQUESTS MUST :BE.: MADE BY-3PM ANY BUSINESS. DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.'
~oFw"TRO City of Wheat Ridge Building Division
m 7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Building Permit Application
Date:
Plan A U"t ^C.-L& O
Permit
Property Address: ~73 I 1 ~G
Property Owner (please print): -ri,, i t~fv.brnf'd Phone: 03-gZ7--8719
Mailing Address: (if different than property address)
Address:
City, State,
Contractor:
Contractor License Phone: 72,0 - 3 / + - ZS L4 6 20¢~
Sub Contractors:
Electrical City License Plumbing City License Mechanical City License
Company: Company Company:
Gllil (-/ecfri L
Exp. Date: Exp. Date: Exp. Date:
Approval: Approval: Approval:
Use of space (description)
Description of-works
RV6,it J~n.tckre_
6-d 6epltcc ciyU
Sq. Ft./L. Ft added:
u IPx Construction Value: $ o
I (as calculated per the Building Valuation Data sheet)
M Z~, , IZer~ Plan Review (due at time of submittal): $ a_
Squares BTU's Gallons Amps
OWNEWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all oth plicable Wheat ge Ordinances, for work
under this permit. Plans subject to field inspection.
CIRLCE ONE:: (OWNER) Cor PERSONAL REPRESENT IV of (O E ) NTRATOR)
PRINTNAME: SIGNATURE: Date:
Bldg Valuation: $
WEECYCLE ENVIRONMENTAL CONSULTING. INC.
5375 Western Avenue, Suite B
Boulder, Colorado 80301
(303) 413-0452 Fax (303) 413-0710
August 12, 2009
PHI Homes
Roger Peterson
4892 Van Gordon
Unit 202
Wheatridge, CO 80033
Re: PCM analysis on August 7, 2009 for 4753 Holland St. Wheatridge, Colorado 80033
Dear Mr. Peterson:
David Sawitsky, a State of Colorado certified AMS (Air Monitoring Specialist) with
Weecycle Environmental Consulting, Inc. performed a final visual and air sampling using
Phase Contrast Microscopy (PCM) analysis of final clearance samples collected on
August 7, 2009 for 4753 Holland St. Wheatridge, Colorado 80033.
The samples were analyzed at Weecycle Environmental Consulting Laboratory, and the
Project Supervisor was given a verbal summary of the results within 2 hours. The
analytical results are presented in Table 1 of the enclosed report. The analysis was
performed in accordance with the PCM method outlined in the NIOSH 7400 Method.
The visual inspection and clearance sample results, which were below the MAAL
(Maximum Allowable Asbestos Level), render this containment free of debris and clear of
asbestos.
Weecycle's job number for this project is 09-02372. If you have any questions, please
call Lauren York at (303) 413-0452.
Submitted By:
Lauren York
State of Colorado Asbestos Inspector #3748
C:\DOCUME-l\Owner\LOCALS-l\Temp\Holland St. Clearence.doc
y q 11 r
GOLDEN ENGINLLRWG GROUP LLC
PHI Homes
11953 West 56`h Circle
Arvada, Colorado 80002
Attn: Mr. Roger Peterson
Re: Inspection Report
4753 Holland Street
Wheat Ridge, CO 80033
July 31, 2009
Per your request, Golden Engineering Group, LLC has performed an inspection of the property
located at 4753 Holland Street, Wheat Ridge, Colorado. The purpose of our inspection was to
assess the extent of structural damage caused by a large Cottonwood tree that fell onto the
southwest corner (rear) of the structure. The tree, which was located in the back yard of the
property, was blown over as the result of high winds associated with a storm that occurred the
night of July 20, 2009. Due to the potential for structural instability, the property was identified
by the City of Wheat Ridge (City) as Hazardous and it is now unoccupied. This report outlines
the extent of damages known at this time and the recommended steps to take during the repair
of the structure to ensure the safety and integrity of the structure.
Background
The following information is based, in part, on our inspection of the property that took place on
July 24, 2009. The structure is a ranch style duplex built in the 1970's. For the purpose of this
report, the front of the structure faces east and therefore there is a north and south unit to the
duplex. The south unit (4753 Holland St.) was damaged by the falling tree. The duplex is a
traditional wood-framed structure secured to a concrete crawl space foundation which appears
to be constructed as an 8" grade beam on a continuous footer set appropriately below frost
grade. The exterior and interior walls are framed with 2" x 4" common fir studs at 16" on
center. The observed headers are made of solid 4" x 10" beams set on 2" x 4" trimmers loaded
to the foundation through the floor system. The floor system is constructed with wood joists
bearing on the foundation walls at the perimeter and on an interior grade beam in the center.
The exterior sheathing is an asphalt board used commonly during the time of construction. The
exterior veneer is a mix of brick masonry and hardboard painted siding. The headers over
windows are wrapped with hardboard painted trim. The roof system is a hip design framed with
manufactured trusses. The roof pitch is approximately 4 in 12. The sheathing is''/:" plywood
with a tar paper weather barrier and 3-Tab shingles. There are currently two layers of shingles
on the roof.
16542 West 551n place Golden, Colorado 80403 Office 303.216.2850 Fax 303.216.0325
4753 Holland Street _
Wheat Ridge, CO
Storm Damage Assessment Report
Page 2 of 6
July 31, 2009
The interior walls are gypsum board with painted texture. The texture was tested and found
to have 4% crystalline asbestos. The floor coverings are carpet and pad in the affected area.
The structure is heated by a hot water boiler system. There does not appear to be a cooling
system in place. The contents from the occupants are still in place. There is a large amount of
debris scattered over the occupants' personal belongings. Dust resulting from the impact is
spread throughout the home. The water from the storm did penetrate through the opening left
by the tree impact but until the contents are removed we cannot assess if any damage occurred
to the floor system.
Damage Assessment
The Cottonwood tree in the back yard was blown over as a result of the trunk being snapped
several feet above the ground surface from the force of high winds. The tree fell onto the
southwest corner of the roof over a bedroom. The tree fell at a nearly forty-five degree angle to
the home striking over the tops of both windows in the bedroom. The impact split through the
roof plywood decking and crushed the hip and common jack trusses and continued into the
headers of the windows which were ripped from the wall framing forming a large hole through
the roof and wall system. Although the majority of the impact was vertical, there was a
rotational component which caused the brick veneer to sheer and fall away form the walls
slightly. The rotational force has created the greatest potential for future wall system failure if
disturbed by anyone removing contents or making repairs. As a result, this unit was closed by
the City until repairs could be made to secure the wall and roof system.
Foundation Assessment
The tree caused damage to the roof system, the wall framing system, the brick veneer, the
windows, the drywall, and the contents. However, based on our observations to date, there
does not appear to be damage to the foundation system. There are no visible cracks in the
foundation grade beam walls and the foundation has not undergone downward movement or
settlement as a result of the impact. Based on these observations we believe the foundation
will not need repairs or adjustments of any type.
Wall and Roof Stabilization
With the destruction of the top plates and headers, the wall system cannot support the roof
system repairs required. Before rebuilding the wall system, temporary support of the roof must
be made. We recommend installing a temporary beam under the trusses in the affected area
supported by 4" x 4" posts which in turn are supported on a temporary double 2" x 8" plate
applied over the at least three floor joist spans. After these beams are in place, a representative
of this office must inspect the supports before construction can continue. Before framing the
walls, the brick veneer must be removed approximately four to six feet beyond the extent of the
west and south walls of the bedroom. Care should be taken to avoid large section removal as
the veneer is already pulling away from the wall structure. After the brick is safely removed, the
4753 Holland Street Page 3 of 6
Wheat Ridge, CO July 31, 2009
Storm Damage Assessment Report
walls can be reframed and sheeted with double top plates and double 2" x 10" headers over the
windows. It is important to ensure adequate pressure blocking to the foundation under the
trimmers supporting the hip master. Once the wall system is in place, the roof can be repaired.
Roof Structure Repair Recommendation
The primary concern for the structural integrity of the roof system is the damage done to the
hip master which bears on the north end of the west window header in the bedroom. The hip
master carries the load of a common full span truss on a twenty-four inch center plus the
additional loads added by the hip and common trusses attached to it. The stresses are carried
through the truss members at connecting points supported by steel plates. These plates appear
to have loosened and there are splits in some of the members. In it's current condition, we
believe the potential for a future catastrophic failure of the truss under full loading is likely and
recommend it be replaced or supported adequately to handle the expected live and dead loads
the truss must carry.
We considered two options: 1) remove the existing truss or installing a sister truss next to it; and
2) re-supporting the truss in place. In our evaluation we considered the cost of removing a full
width portion of the roof required to fit a new truss to the cost of partial roof removal and the
installation of a support beam to carry the roof loads. From a value engineering standpoint, the
second option is the better of the two. Option 2) will cost less, be quicker to install, and cause
the least disturbance to the roof decking and drywall below. Minimizing disturbance is critical
considering the cost of further contamination to the structure from asbestos if additional
drywall needs to be removed.
Our recommendation is to apply two 14" x 1 Laminated Veneer Lumber (L.V.L.) members
along the full length of the damaged hip master. The beam shall be applied to the north side of
the truss at the bottom chord. This will limit the need to cut back bottom ceilingjoists of the hip
and common trusses thereby reducing the potential for cutting into the drywall ceiling below.
The double member shall be connected to the existing truss at each gusset connection using'
x 6" bolts. In addition, the top connecting plates shall be reinforced with plywood gussets
nailed to the truss with 8p ring shank nails spaced no more than three inches on center. This
will ensure the top chord loads will be fully transferred to the beam below. Access, where
needed to install the support beam and the upper gusset reinforcements shall be made by
removing small sections of the roof between the hip master and the next truss to the north.
Before replacing the roof deck openings, this office shall inspect the truss repairs to ensure the
intent of the remedial design is met.
For the smaller truss repairs, rather than ordering small hip and common jack trusses, these
remaining damaged trusses can be refrained on site with standard dimensional 2" x 6" top
rafters and 2" x 4" ceiling joists. While under construction, these members and their
connections must be inspected by a member of this office. This inspection can occur with the
hip master inspection to limit travel costs.
4753 Holland Street
Wheat Ridge, CO
Storm Damage Assessment Report
Conclusions
Page 4 of 6
July 31, 2009
The structural integrity of the roof and wall systems was partially destroyed by a tree falling
onto south duplex unit. However; the foundation system does not appear to be damaged and
construction to reestablish the structure may commence as soon as possible. This office
recommends temporary support be put in place to keep the roof from failing during repair to
the wall system. The walls must be repaired and then the roof truss system can be repaired by
adding a supporting beam to the hip master truss which was compromised by the impact of the
tree. This office will perform field inspections to ensure the structure is supported and repaired
as outlined in this report.
Our report is based on the information available to us at this time. Should additional
information become available, we reserve the right to determine the impact, if any, the new
information has on our opinions and conclusions and to revise our opinions and conclusions if
necessary and warranted. Should you have any questions or need any further clarifications,
please do not hesitate to call me at 303.216.2850.
Sincerely,
/q OBA~°Pj 4AU1
cs
3'1665 a
'l
Jonathan P. Friedman, P.E.
Golden Engineering Group, LLC
File: 7-24-09-inspection Report 4753 Holland
4753 Holland Street Page 5 of 6
Wheat Ridge, CO July 31, 2009
Storm Damage Assessment Report
AREA OFIMPACT
vxoas x ns
57TCKFRAME HIP AND COMMON L~ BRACE DAMAGED HIP MASTER
MEMBERS WITH 2X6 TOP CHORDS WITH 2-14"X1314" L. V.L.
AND 2X4 BOTTOM CHORDS (7YP)
N FOLLOW ENGINEER LETTER
FOR ATTACHING TO TRUSS
1i1
/ '
(
DEPARTMENT OF PLANNING AND DEVELOPMENT
BUILDING INSPECTION LINE - 303-234-5933
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Building Permit Number:
Date:
10349
4/10100
Property Owner:
Property Address: 4753 & 4755 HOLLAND ST
Contractor License No. : 20623
Company: JA Roofing Inc.
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Phone: 892-1122
Phone: 238-5734
I hereby certify that the setback distances proposecl by this perm~ application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and aUegations
made are accurate; that I have read and 89,ree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U,B.C.) and all other applicable Wheat Ridge orclinances, for work under this permit.
(OWNER)(CONTRACTOR) SIGNED
DATE
Description:
Add 1 layer to existing 2 layers Tamko 25 yr, 3 tabs shingles
BUILDING DEPARTMENT USE ONLY
Approval :
Approval:
Occupancy:
Roof:
Stories:
Walls:
Electrical License No :
Company:
Plumbing License No :
Company:
Expiration Date :
Approval:
Expiration Date :
Approval :
Construction Value:
Permit Fee:
Plan Review Fee:
Use Tax:
Total:
$2,800.00
$83.25
$0.00
$42.00
$125.25
Use:
SIC:
Sq. Ft.:
Residential Units:
Mechanical License No :
Company:
Expiration Date:
Approval:
(1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws oftha State of Colorado and to the Zoning
Regulations and Building Code of Wheat Ridge, Colorado or any other a{)pllcable ordinances of the City.
(2) This permit shall expire if (A) the work. authorized is not commencecl withm sixty (60) days from issue date or (B) the building authorized Is suspended or
abandoned for a period of.120 dar.s.
(3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new pennlt.
l4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
S) Contractor shall notify the Building Inspector twenty-four (24) hours In advance for all inspections and shall receive written approval on Inspection card before
proceediing with successive phases of the/'Ob.
(6) The Issuance of a pennit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions
:~~:"~iz1;::."~-
DEPARTMENT OF PLANNING AND DEVELOPMENT
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Building Permit Number:
Date:
APPUCJ\TIDN
Property Owner: JD~^,.J. .:J""'AlI'f cS A 4(('<<(1-
Property Address: if 153.j... <I 7 5\5~ ;.I" / / AN J sf
Contractor License No.: J;2D & d 3
Company: -.- A f'I " ~
'>.oJ, . ~~LS tt~J .....LA/(".
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Phone :,k> 3 '?''1 i:. II G z.
I hereby certify that the setback distances proposed by this pennit application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate: that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicab Wheat Ridge ordinances, for work under this pennit.
/'
Phone '.j,',? Q3'?' s-7J<j
Construction Value: "C/ {)
""'0
Permit Fee:
Use Tax:
(OWNER)(CONTRACTOR) SIGNED'
v
DATEo/-!( ..,.J
Total:
D crpton.:J "R",,,.,. J,"" //'IJY> 1:0
es i i . (\OO r, ~~ v CA....-
;<~-v.e
Use:
:3 /,46$ ..$),;<-15'/e$
BUILDING DEPARTMENT USE ONLY
~lJg."'PIJ1l\lents:)
Approval:
Zoning: .
~!IgI~:mmeI'lWl
Approval:
!;1;I~!!S'!!Y.~mlJJ!lJlJSil
Approval:
Occupancy: Walls:
SIC:
Sq. Ft:
Roof:
Stories:
Residential Units:
Electrical License No :
Company:
Plumbing License No :
Company:
Mechanical License No :
Company:
Expiration Date:
Approval:
Expiration Date :
Approval:
Expiration Date:
Approval:
(1)
(2)
(3)
This permit was iSSued in aeeordance witt'. the provisions set forth in yopur application and is subject to the Laws of the State of Colorado and to the ~oning
Regulations and Buildin~ Code ot WheEl: Ridge. Colorado or any otner applicable ordinances of the City.
This permit shall eXf)lre if (A) the wort iluthonzedis not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or
abandoned, for a,penod of 120 days
If this permit expIres. a new perml' may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspenSion or abandonment
exceeds one (1) year, full fees shall be paid for a new permit
No work of any manner shall be done that will change the natural flow of water causing iI drainage problem.
Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before
proCeedilng wif,b successive phases of the job.
The issuance of a permit or the approval of drawings and Specifications shall not be construed to be a permit for, nor an approval of, any violation of ttle provisions
of the building codes or any other ordinance, law, rule or regulation.
(4)
(5)
(S)
Chief Building Inspector