HomeMy WebLinkAbout12376 W. 34th PlaceCity of Wheat Ridge
Residential Mechanic PERMIT - 201801982
PERMIT NO: 201801982 ISSUED: 07/11/2018
JOB ADDRESS: 12376 W 34th PL EXPIRES: 07/11/2019
JOB DESCRIPTION: Install a breezair EXV 275 with roof kit and ducting for 6 vents
*** CONTACTS ***
OWNER (303)522-2312 JACOBSON FRANK
SUB (303)422-5308 Steve Brandt 021365 The Cooler Company
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,300.00
FEES
Total Valuation 0.00
Use Tax 90.30
Permit Fee 125.05
** TOTAL ** 215.35
*** COMMENTS ***
*** CONDITIONS ***
Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required
to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every
level of the structure.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document andlor its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po Flans
and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and maybe subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a pet shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable cod r ny �rdmanc r regulation of this jurisdiction. Approval of work is subject to f any
inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
lvy OT i Af,ta-, tlagp
LH
Ju1.11.2018 12:50 AM COOLER COMPANY 3032711860 P 1/ 3
41.►V City or
+!
A� Wheat idgc
COMMUNITY DEVELOPMENT
Building 6 Inspection Services Dlvlslon
7500 W. 291" Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Une: 303-234-5933
Email: i)ermits(a)-ci.wheatrid-ge.co.us
j FOR OFFICE USE ONLY
Date: 7 I / ) 1 / T
.,,,_
Plan/Permlr is X19 1 %/
Plan Review Fee:
Building Permit Application
Please complete all highlighted areas on both sides of this; form. Incomplete appilcatlons
may not be processed. ""**
Property Address:
1231 � w 3w pl
Property. Owner (please print): Fra n Ki Toy it ba n Phone: 5b3-6271-2,312-
Property
a3"5 ZZ-231ZProperty Owner Email:
Tenant (Commercial Projects Oniy)
Property Owner Mailing Address: (if different than property address)
Address:
City, State, Zip:
Arch ltect/Englneer E-mail: Phon®:
n
City of. Wheat. Ridge License .#: 2 (01H 1-0 0( Phone: L3 D 3 -qZ2 - 5 3a %
Contractor E -mall Address; C/0Q177(,0'& 1161 • tVffl
For Plan Review Questions &.Comments (please print):
CONTACT NAME, (please prlpt):.' hiz/vn AI Wn Phon®: 363"4a-p"6aO
'CONTACT EIIAAIL(please print): o (di �C d I aj � • -.o r✓�
,Sub Contractors (Must. provide Wheat Ridge License No.):
Electrical: Plumbing: Mechanlcal:
W.R. City License # W.R. City License # W.R. City License #
Other City Licensed Sub: Other City Licensed Sub:
City License # City License #
Ju1.11.2018 12:50 AM COOLER COMPANY 3032711860 P 2/ 3
❑ COMMERCIAL ESIDENTIAL
DeSdin� current ue of tsquare footage, 'existing proposed usesr s ription of work to be performed,,
ting condition and proposed new
condition, appliance size and efficiency, type and amount of materials to be used, etc,
t nsfi�Ll �rccmi Exv 2-1,5 w 'Ifih roof Nt-o net AUChao
f r U VCAV
Commercial Projeets Only: Occupancy Type: Construction Type:
Sq. FULF
Amps
BTUs Gallons
Squares
Project Value:, (Contract value or the cost of all materials and labor included in the entire project)
�XVRVIIM
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify th(a clic setback distances proposed by this permit application are accurate and du nut viulatc applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, oasaments or restrictions of record; that all measurements shown and allegations made are
uccuratc; that i have read and agree to abide by all conditions printed on this application and that i assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances 'Cur work undur any penuit issued based on this application; that I nin the legal owner
or have bcui authorized by the legal owner of the property to perform the described work and am also aathorizcd by the legal owner of any
entity included on this application to list that entity on this appliention, 1, the applicant ror this building permit application, warrant the
truthfulness of the information provided on the application,
CrRCLE ONE., (OWNER) (CO R CTOR) a AU' . 177;0 MPNESENTAT/ ) of (OWNER) (CONTRACTOR)
i n u (first and last tame): 67,11 vl g
Printed Namo:
INSPECTION RECORD
Inspection online form: http://www.ci.wheatridge.co.us/inspection
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site
Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day
PERMIT: ��� 01� ADDRESS: 1a3 1b PJ,/ JOB CODE:
Foundation Inspections
Date
Inspector
Initials
Comments
102 Caissons / Piers
103 Footing / P.E. Letter
104 Foundation Setback Cert.
105 Stem Walls
106 Foundation wall Insulation
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground / Slab Inspections
Date
Inspector
Initials
Comments
201 Electrical / Cable/ Conduit
202 Sewer Underground Int.
203 Sewer Underground Ext.
204 Plumbing Underground Int.
205 Plumbing Underground Ext.
206 Water Underground
lg
Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections
Rough Inspection
Date
Inspector
Initials
Comments
301 Rough Framing
302 Wall Sheathing
303 Roof Sheathing
304 Sheer Inspection
305 Insulation
306 Mid -Roof
lg
307 Metal / Lath / Stucco
308 Rough Electrical Residential
309 Rough Electrical Commercial
310 Electrical Meter Residential
311 Electrical Meter Commercial
312 Temp. Const. Meter
313 Rough Plumbing Residential
314 Rough Plumbing Commercial
315 Shower Pan
SEE OVER FOR ADDITIONAL INSPECTIONS
PERMIT:��SOY� ADDRESS
No(q w., FLi JOB CODE: _J��
Rough Inspection (continued)
Date
Inspector
Initials
Comments
316 Rough Mechanical Residential
317 Rough Mechanical Commercial
318 Boiler / Furnace
319 Hot water tank
320 Drywall screw and Nail
321 Moisture board / shower walls
322 Rough Grading
323 Miscellaneous
11 T-
Final Inspections
Date
Inspector
Initials
Comments
402 Gas Meter Release
403 Final Electrical Residential
404 Final Electrical Commercial
405 Final Mechanical Residential
406 Final Mechanical Commercial
407 Final Plumbing Residential
408 Final Plumbing Commercial
409 Final Roof
11 T-
410 Final Window/Door
411 Landscape/Park/Planning"
Inspections from these entities shall be requested
one week in advance.
*For landscaping and parking inspections please
call 303-235-2846
**For ROW and drainage inspections please call
303-235-2861
'For fire inspections please contact the Fire
Protection District for your project.
412 Row/Drainage/Public Works*'
413 Flood plain Inspection**
414 Fire Insp. / Fire Protection***
415 Public Works Final**
416 Storm Water Mgmt.**
417 Zoning Final Inspection*
418 Building Final Inspection
Note: All items must be completed and approved by Planning, Public Works, Fire and Building
before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not
constitute authorization of occupancy.
For Low Voltage permits please be sure that rough inspections are completed by the Fire District and
Electrical low voltage by the Building Division.
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234 -5933 -Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: L) 09 r - t2 :,=z
Job Address: Q 27
Permit Number: 1
►/
❑ No one available for inspection: Time `i; PM
Re -Inspection required: Yes N
When corrections have been made, cat re -inspection at 303-234-5933
Date:_ f ! s I) Inspector: c 4.,
DO NOT REMOVE THIS NOTICE
e
City of Wheat Ridge
Residential Roofing PERMIT - 201800349
PERMIT NO: 201800349 ISSUED: 02/05/2018
JOB ADDRESS: 12376 W 34th PL EXPIRES: 02/05/2019
JOB DESCRIPTION: Reroof house, garage and porch with Malarkey Vista dimensional asphalt
shingles IR 3 rating, 4/12 pitch on house, 2/12 pitch on porch; 36 squares
total
*** CONTACTS ***
OWNER (720)397-0983
HANSEL GRANT
SUB (720)432-6770
David Earl & Stuart Allen
022298 J.A. Roofing
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE: UA / Unassigned
SUBDIVISION CODE:
2403 / APPLEWOOD
VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY ***
ESTIMATED
PROJECT VALUATION: 9,252.00
FEES
Total Valuation
0.00
Use Tax
194.29
Permit Fee
204.30
** TOTAL **
398.59
*** COMMENTS ***
*** CONDITIONS ***
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required for both the midroof and final inspections. The 3rd party inspection report AND
THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat
Ridge. The report MUST BE SIGNED by the Homeowner.
REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec.
R806. The installation of ridge venting requires the installation or existence of soffit
venting. For calculation purposes, one hat or turtle vent equal to one-half of one square
foot of opening.
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name) roof
covering" is required to be on site at the time of final inspection.
I by my signature, do hereby attest that the work to be performed shall comply with all accompanyingg approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am C legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
perform d,#nd that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
2-1
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature 16f Chief Building4Offi'cia'l 'U"--- Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of Wheat Ridge
Residential Roofing PERMIT - 201800349
PERMIT NO:
201800349
ISSUED:
02/05/2018
JOB ADDRESS:
12376 W 34th PL
EXPIRES:
02/05/2019
JOB DESCRIPTION:
Reroof house, garage and porch with
Malarkey Vista dimensional asphalt
shingles IR 3 rating, 4/12 pitch on
house, 2/12
pitch on porch; 36 squares
total
I by my signature, do hereby attest that the work to be performed shall comply with all accompanyingg approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am C legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
perform d,#nd that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
2-1
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature 16f Chief Building4Offi'cia'l 'U"--- Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Kimberlv Cook A)i�W3�
From: no-reply@ci.wheatridge.co.us
Sent: Friday, February 2, 2018 1:38 PM
To: CommDev Permits
Subject: Online Form Submittal: Residential Roofing Permit Application
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
Property Owner Email
Address
12376 w 34th place
JDI Homes Inc
303-437-7292
ssjones8@gmail.com
G
Do you have a signed Yes
contract to reroof this
property?
Applications cannot be
submitted without an
executed contract
attached below.
Attach Copy of Executed Scan.pdf
Contract
CONTRACTOR INFORMATION
Contractor Business
Name
Contractor's License
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Address
(Primary address of your
business)
JA Roofing
022298
303-378-7959
10726 W. Berry Dr Littleton CO 80127
Contractor Email Address j.a.roofinginc@live.com
Retype Contractor Email j.a.roofinginc@live.com
Address
DESCRIPTION OF WORK
TOTAL SQUARES of 36 sq
the entire scope of work:
Project Value (contract
value or cost of ALL
materials and labor)
Are you re -decking the
roof?
Is the permit for a flat
roof, pitched roof, or
both? (check all that
apply)
m
Pitched roof (2:12 pitch or greater)
2
What is the specific pitch
of the PITCHED roof?
How many squares are
part of the PITCHED
roof?
Describe the roofing
materials for the
PITCHED roof:
Type of material for the
PITCHED roof:
Provide any additional
detail here on the
description of work. (Is
this for a house or
garage? Etc)
4/12 on the house roof and 2/12 on the porch
36
malarkey vista dimensional shingles IR 3 rating
Asphalt
house/garage/porch
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been
authorized by the legal
owner of the property to
submit this application
Yes
Yes
Yes
Yes
3
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Name of Applicant Jeff Aguon
Email not displaying correctly? View it in your browser.
)0
i CITY OF WHEAT RIDGE
Building Inspection. Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number: C
❑ No one available for inspection: Time j, /U (?UM
Re -Inspection required: Yes No ��1
When corrections have been made, call for re -inspection at 303-234-5933
Date: Inspect r: -
DO NOT REMOVE THIS NOTICE
Occupancype
IN0;9�PT'10N D
RECOR
INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection
INSPECTION REQUEST LINE: (303) 234-5933
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site.
**Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.**
Inspector Must Sign ALL Spaces pertinent to this project
Foundation Inspections Date
Inspector Comments
Initials
Pier
Wall Sheathing
Concrete Encased Ground (CEG)
Foundation / P.E. Letter
Mid -Roof
uo Not Four Concrete Prior To Approval Of The Ahnvp Incnpr_finnc
Underground/Slab Inspections Date Inspector Comments
Initials
Electrical
Sewer Service
Plumbing
uo Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Ins ections
Rough Inspections
Date
Inspector
Initials
Comments
Wall Sheathing
Mid -Roof
Lath / Wall Tie
Rough Electric
Rough Plumbing/Gas Line
Rough Mechanical
Rough Framing
Rough Grading
Insulation
Drywall Screw/ Nail
Final Inspections
Date
Inspector
Initials
Comments
Landscaping & Parking / Planning Dept.
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
ROW & Drainage/ Public Works Dept.
Floodplain Inspection (if applicable)
Fire Inspection / Fire Protection Dist.
Final Electrical
l
Final Plumbing
'
Final Mechanical
Roof
Final Window/Doors
Final Building
NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate
of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy.
VI -VV VWI.ayC VVI IIIIIA — crease ue sure Inas rougn inspections are completed from the Fire District and electrical low voltage
by the Building Division.
Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued
Protect This Card From The Weather
City of Wheat Ridge
Residential Electric PERMIT - 201706561
PERMIT NO: 201706561 ISSUED: 08/24/2017
JOB ADDRESS: 12376 W 34th PL EXPIRES: 08/24/2018
JOB DESCRIPTION: residential electric upgrade from 100 amp to 200 amp overhead
*** CONTACTS ***
OWNER (303)437-7292 GARRETT JONES
SUB (720)620-7041 Lou Santanostasi 021892 Platinum Electric Inc.
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 1,600.00
FEES
Total Valuation 0.00
Use Tax 33.60
Permit Fee 63.90
** TOTAL ** 97.50
*** COMMENTS ***
*** CONDITIONS ***
Work shall comply with 2012 IRC & 2014 NEC. Per IRC Sec. R314, smoke detectors are required
to ne irioualled in every :iiCt: iii^y room'., in 1-allv,;ays .,,:ts-_J c a- =y,7 _ , L=q, anu vn PV-,,
level of the structure.Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection.Mus*_
comply w/ 2012 IRC & 2014 NEC. Subject to field inspection.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
bythe legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this_permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations. policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of'
the Chief Building Official and is not guaranteed.
4, No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
INSPECTION RECORD
Inspection online form: http://www.ci.wheatridge.co.us/inspection
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site
Request an itis�pection bef [e IV�IDNIGHT (11:59�PN�1-},�� i an inspe��iojt�� owing busines �a�y�,�
PERMIT: / ADDRESS: ol/ G� 1 �1�/{ r� B ODE: ;W:'IAA
V
Foundation Inspections
Date
Inspector
Initials
' Q
102 Caissons / Piers
103 Footing / P.E. Letter
/d!;
i- eke
104 Foundation Setback Cert.
105 Stem Walls
106 Foundation wall Insulation
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground I Slab Inspections
Date
Inspector
Initials
Comments
201 Electrical / Cable/ Conduit
202 Sewer Underground Int.
203 Sewer Underground Ext.
204 Plumbing Underground Int.
205 Plumbing Underground Ext.
206 Water Underground
Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections
Rough Inspection
Date
Inspector
Initials
Comments
301 Rough Framing
302 Wall Sheathing
303 Roof Sheathing
304 Sheer Inspection
305 Insulation
306 Mid -Roof
307 Metal / Lath / Stucco
308 Rough Electrical Residential
309 Rough Electrical Commercial
310 Electrical Meter Residential
311 Electrical Meter Commercial
312 Temp. Const. Meter
313 Rough Plumbing Residential
314 Rough Plumbing Commercial
315 Shower Pan
SEE OVER FOR ADDITIONAL INSPECTIONS
PERMIT:% S �l ADDRESS: %,-;�3/( k) 3V-i� JOB CODE: /ZOJ/AJ
Rough Inspection (continued)
Date
Inspector
Initials
Comments
316 Rough Mechanical Residential
317 Rough Mechanical Commercial
318 Boiler / Furnace
319 Hot water tank
320 Drywall screw and Nail
321 Moisture board / shower walls
322 Rough Grading
323 Miscellaneous
Final Inspections
Date
Inspector
Initials
Comments
402 Gas Meter Release
403 Final Electrical Residential
404 Final Electrical Commercial
405 Final Mechanical Residential
406 Final Mechanical Commercial
407 Final Plumbing Residential
408 Final Plumbing Commercial
409 Final Roof
410 Final Window/Door
411 Landscape/Park/Planning*
Inspections from these entities shall be requested
one week in advance.
*For landscaping and parking inspections please
call 303-235-2846
**For ROW and drainage inspections please call
303-235-2861
'For fire inspections please contact the Fire
Protection District for your project.
412 Row/Drainage/Public Works'
413 Flood plain Inspection**
414 Fire Insp. / Fire Protection***
415 Public Works Final**
416 Storm Water Mgmt.**
417 Zoning Final Inspection*
418 Building Final Inspection
Note: All items must be completed and approved by Planning, Public Works, Fire and Building
before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not
constitute authorization of occupancy.
For Low Voltage permits please be sure that rough inspections are completed by the Fire District and
Electrical low voltage by the Building Division.
DL ENGINEERING INC.
2750 S. WADSWORTH BLVD.NEW
EGRESS WINDOW AT
DATE:
10/17/2017
JOB#:
2017-3828
REVISION DATE:
PAGE
OF
UNIT D-203
12376 W. 34TH PLACE
DENVER, CO 80227
720-440-9450
WHEAT RIDGE, CO 80033
OWNER: JONES
----
SK -2
2
BY:
CHECKED BY:
WWW.DLENGINEER.COM
MW
GT
(E) SILL PLATE
C�
Z
z
w
Mn
L
(N) EGRESS WINDOW
(N) AREAWAY WELL
36" WIDE MIN.
IF DEEPER THAN 44"
PROVIDE LADDER
3' MIN
Ili=—1 l l_ (E) EXTERIOR
GRADE
� z
EGRESS WINDOW SECTION
NOTE: WINDOW WILL HAVE
MIN 5.7SQ. FT. OPENABLE
AREA, WITH A CLEAR
HORIZONTAL WIDTH OF 20"
AND 41" VERTICAL.
of 2'
Z
M
(E) CONCRETE WALL
1
UkDL Engineering Inc.
Structural / Civil Engineering
2750 South Wadsworth Blvd D-203
Denver, CO 80227
720-440-9450
www.diengineer.com
10/17/2017
Garrett Jones
JDI LLC.
RE: 12376 W. 34`h Place
Wheat Ridge, CO 80033
Modified Window Opening
Per your request, a site visit was performed October 17, 2017 at the above address to observe the
existing foundation and structural components with respect to modification of a basement window. The
residence is a single story wood framed structure with a brick veneer and an unfinished basement. For
the purpose of this report, the residence faces north.
It is our understanding the existing window opening on the west wall of the basement approximately 6'-
3" from the south wall is to be modified to accommodate an emergency egress from the basement in
accordance with the City of Wheat Ridge Building Department requirements. The existing opening is to
be extended from the bottom of the existing steel sill to a sill height on the order of 40 inches. The
width of the opening will not be altered.
It is our opinion that the foundation wall is considered adequate to support the following required
structural loads after the window is modified:
Design criteria:
2012 IRC
2012 IBC
City of Wheat Ridge Amendments
Roof LL: 20psf
Roof DL: 10psf
Roof Snow Load: 30psf
Wind Load:
105 MPH, 3 -sec gust
Exposure C
Seismic Category: B
There are signs of lateral movement in the foundation. Monitor the walls for additional lateral
movement, future wall anchors may be required.
It is recommended that the wall that is adjacent to the new window is backfilled in thin lifts and
compacted to minimize backfill settlement. The ground surface should be sloped to direct surface water
away from the windows and foundation.
The recommendations in this report are based on observed conditions. DL Engineering Inc. does not
accept any liability for unknown defects in the design or construction or the original structure at this
site.
DL Engineering Inc.
Structural / Civil Engineering
In as much as the site review of an existing structure for the purpose of observing the structure
conditions requires that certain assumptions be made regarding existing conditions and because some
of these assumptions may not be verifiable without expending additional sums of money or destroying
otherwise adequate or serviceable portions of the building, the Client agrees that, except for negligence
on the part of the Engineer, the Client will hold harmless, indemnify and defend Engineer from and
against any and all claims arising out of the professional services we have provided.
If you should have any further questions, please feel free to contact me at (720) 440-9450 or
mweber@dlengineer.com.
Sincerely,
Matt Weber, EIT
Under the direct supervision of,
Garrett Townsend, PE
Job # 2017-3828
Attached: SK -1 Egress Window Elevation
SK -2 Egress Window Section
F9
DL ENGINEERING INC.
2750 S. WADSWORTH BLVD.NEW
EGRESS WINDOW AT
DATE:
10/17/2017
JOB#:
2017-3828
REVISION DATE:
PAGE
OF
UNIT D-203
12376 W. 34TH PLACE
DENVER, CO 80227
720-440-9450
WHEAT RIDGE, CO 80033
OWNER: JONES
----
SK -1
2
BY:
CHECKED BY:
WWW.DLENGINEER.COM
MW
GT
EGRESS WINDOW ELEVATION
1 /2" =1'-0"
(E) SILL PLATE
(E) STEEL WINDOW
FRAME DO NOT CUT
HEADER AND
MINIMIZE CUT TO
VERTICAL MEMBERS
E) EXTERIOR
'RADE
DEMO CONCRETE
MINIMIZE OVERCUT
(E) CONCRETE
WALL
'OP OF
;LAB
4" SLAB
1
GL ENGINEERING. INC
1750 Sf iB.SV�If 9 ?C7
11197[8 fOBM
720-4414450
1/15/2018
Complete Basement Systems
11795 East 45`h Ave.
Denver, CO 80239
RE: Job Number 2017-3828
Site Observation Visit (Jones)
12376 W. 34`h Place
Wheat Ridge, CO 80033
DL Engineering Inc. reviewed the progress of construction for the subject project on January 12, 2018.
The following is a summary of the observations made:
New Observations:
Reviewed the wall anchors. There were 10 wall anchors installed in the south wall
spaced at approximately 6'-6" o.c. The interior and exterior steel plates were observed.
o The wall anchor spacing was observed and appears to be in conformance with
the construction documents.
o The exterior plates were located a minimum of 12' from the house. The top of
the plates were a minimum of 3' below existing grade.
o The wall anchors appear to be installed in conformance with the structural
mitigation plan.
Site grading around the perimeter of the house did not appear to be modified.
Vegetation around the perimeter of the house did not appear to be modified.
Volatile Soils:
The moisture around the foundation elements must be controlled for the useful life of the building.
Time has shown that Colorado soils can be unstable and structures can experience damaging
movements due to expanding and shrinking soils, primarily when moisture changes occur. Maintaining
consistent soil moisture contents around all foundation elements is crucial to minimizing foundation
movements. Even with properly engineered/constructed foundation systems these volatile soils can still
exert excessive pressures causing damage in the residence. If the Owner would like further insight
about the on-site soil conditions and preventative measures, a Geotechnical Engineer should be
consulted.
Geotechnical Consideration:
It is possible that the wall anchors may consolidate the soil behind the foundation wall. Because of this,
periodic surveys of the supported structures should be conducted to assure project success. The Owner
should be responsible for annual surveys certifying project success. It is recommended that a baseline
survey be conducted immediately. The Owner should report all findings and reports to the Structural
Engineer. If horizontal movement of the foundation walls or wall anchors is discovered, the anchors
should be re -tensioned. A Geotechnical Engineer should be present for the re-torqueing of the wall
anchors.
❑L ENGINEERING. INC.
i
��
Disclaimer:
In as much as the site review of an existing structure for the purpose of observing the structure
conditions requires that certain assumptions be made regarding existing conditions and because some
of these assumptions may not be verifiable without expending additional sums of money or destroying
otherwise adequate or serviceable portions of the building, the Client agrees that, except for negligence
on the part of the Engineer, the Client will hold harmless, indemnify and defend Engineer from and
against any and all claims arising out of the professional services we have provided.
If you should have any further questions, please feel free to contact me at (720) 440-9450 or
mweber@dlengineer.c
Sincerely,
Matt Weber, PE
Under the direct supervision of,
Garrett Townsend, PE ---
2
i?Qs ",� Z
10/17/2017
Garrett Jones
JDI LLC.
RE: 12376 W.34 1h Place
Wheat Ridge, CO 80033
Modified Window Opening
Per your request, a site visit was performed October 17, 2017 at the above address to observe the
existing foundation and structural components with respect to modification of a basement window. The
residence is a single story wood framed structure with a brick veneer and an unfinished basement. For
the purpose of this report, the residence faces north.
It is our understanding the existing window opening on the west wall of the basement approximately 6'-
3" from the south wall is to be modified to accommodate an emergency egress from the basement in
accordance with the City of Wheat Ridge Building Department requirements. The existing opening is to
be extended from the bottom of the existing steel sill to a sill height on the order of 40 inches. The
width of the opening will not be altered.
It is our opinion that the foundation wall is considered adequate to support the following required
structural loads after the window is modified:
Design criteria:
2012 IRC
2012 IBC
City of Wheat Ridge Amendments
Roof LL: 20psf
Roof DL: 10psf
Roof Snow Load: 30psf
Wind Load:
105 MPH, 3 -sec gust
Exposure C
Seismic Category: B
There are signs of lateral movement in the foundation. Monitor the walls for additional lateral
movement, future wall anchors may be required.
It is recommended that the wall that is adjacent to the new window is backfilled in thin lifts and
compacted to minimize backfill settlement. The ground surface should be sloped to direct surface water
away from the windows and foundation.
The recommendations in this report are based on observed conditions. DL Engineering Inc. does not
accept any liability for unknown defects in the design or construction or the original structure at this
site.
DL Engineering Inc.
Structural / Civil Engineering
2750 South Wadsworth Blvd D-203
Denver, CO 80227
720-440-9450
www.diengineer.com
10/17/2017
Garrett Jones
JDI LLC.
RE: 12376 W.34 1h Place
Wheat Ridge, CO 80033
Modified Window Opening
Per your request, a site visit was performed October 17, 2017 at the above address to observe the
existing foundation and structural components with respect to modification of a basement window. The
residence is a single story wood framed structure with a brick veneer and an unfinished basement. For
the purpose of this report, the residence faces north.
It is our understanding the existing window opening on the west wall of the basement approximately 6'-
3" from the south wall is to be modified to accommodate an emergency egress from the basement in
accordance with the City of Wheat Ridge Building Department requirements. The existing opening is to
be extended from the bottom of the existing steel sill to a sill height on the order of 40 inches. The
width of the opening will not be altered.
It is our opinion that the foundation wall is considered adequate to support the following required
structural loads after the window is modified:
Design criteria:
2012 IRC
2012 IBC
City of Wheat Ridge Amendments
Roof LL: 20psf
Roof DL: 10psf
Roof Snow Load: 30psf
Wind Load:
105 MPH, 3 -sec gust
Exposure C
Seismic Category: B
There are signs of lateral movement in the foundation. Monitor the walls for additional lateral
movement, future wall anchors may be required.
It is recommended that the wall that is adjacent to the new window is backfilled in thin lifts and
compacted to minimize backfill settlement. The ground surface should be sloped to direct surface water
away from the windows and foundation.
The recommendations in this report are based on observed conditions. DL Engineering Inc. does not
accept any liability for unknown defects in the design or construction or the original structure at this
site.
DL Engineering Inc.
Structural / Civil Engineering
In as much as the site review of an existing structure for the purpose of observing the structure
conditions requires that certain assumptions be made regarding existing conditions and because some
of these assumptions may not be verifiable without expending additional sums of money or destroying
otherwise adequate or serviceable portions of the building, the Client agrees that, except for negligence
on the part of the Engineer, the Client will hold harmless, indemnify and defend Engineer from and
against any and all claims arising out of the professional services we have provided.
If you should have any further questions, please feel free to contact me at (720) 440-9450 or
mweber@dlengineer.com.
Sincerely,
Matt Weber, EIT
Under the direct supervision of,
Garrett Townsend, PE
Job # 2017-3828
Attached: SK -1 Egress Window Elevation
SK -2 Egress Window Section
DL ENGINEERING INC.
2750 S. WADSWORTH BLVD.NEW
EGRESS WINDOW AT
DATE:
10/17/2017
JOB#:
2017-3828
REVISION DATE:
PAGE
OF
1
UNIT D-203
12376 W. 34TH PLACE
DENVER, CO 80227
720-440-9450
WHEAT RIDGE, CO 80033
OWNER: JONES
--
SK -1
2
BY:
CHECKED BY:
WWW.DLENGINEER.COM I
I
MW
GT
EGRESS WINDOW ELEVATION
1 /2" =V -Q"
(E) SILL PLATE
(E) STEEL WINDOW
FRAME DO NOT CUT
HEADER AND
MINIMIZE CUT TO
VERTICAL MEMBERS
E) EXTERIOR
3RADE
DEMO CONCRETE
MINIMIZE OVERCUT
(E) CONCRETE
WALL
'OP OF
,LAB
4" SLAB
I
DL ENGINEERING INC.
2750 S. WADSWORTH BLVD.NEW
EGRESS WINDOW AT
DATE:
10/17/2017
JOB#:
2017-3828
REVISION DATE:
PAGE
OF
1
UNIT D-203
12376 W. 34TH PLACE
DENVER, CO 80227
720-440-9450
WHEAT RIDGE, CO 80033
OWNER-. JONES
---
SK -2
2
BY:
CHECKED BY:
WWW.DLENGINEER.COM I
I MW
GT
(E) SILL PLATE
Him
(N) EGRESS WINDOW
(N) AREAWAY WELL
36" WIDE MIN.
IF DEEPER THAN 44"
PROVIDE LADDER
3' MIN
i
(E) EXTERIOR
GRADE
� z
EGRESS WINDOW SECTION
1/2" = 1'-0"
NOTE: WINDOW WILL HAVE
MIN 5.7SQ. FT. OPENABLE
AREA, WITH A CLEAR
HORIZONTAL WIDTH OF 20"
AND 41" VERTICAL.
0' 2'
Z
g
co
M
(E) CONCRETE WALL
I
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: i 3 P E_ i-'Zoe
Job Address:
Permit Number: �� I
❑ No one available for inspection: Time I) a/PM
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303-234-5933
Date:) Inspe ort,
DO NOT REMOVE THIS NOTICg
i CITY OF WHEAT RIDGE
1�9�Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: H I 'D W ' ""o �'---)
Job Address: 0- 3'-) G w� LA h, P
Permit Number: c -D 0) 47 (0 q H 9 y
❑ No one available for inspection: Time / : � I/PM
Re -Inspection required: Yes No
When corrections have been made, call re -inspection at 303-234-5933
Date: ► Inspect
y
DO NOT REMOVE THIS NOTICE
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION
City of Wheat Ridge
Residential Basement Finish PERMIT - 201800121
201800121 ISSUED: 01/11/2018
12376 W 34th PL EXPIRES: 01/11/2019
Foundation Stabilization - wall anchors
*** CONTACTS ***
OWNER (303)437-7292 JONES GARRETT
GC (303)805-8751 Rodney Martin
*** PARCEL INFO
ZONE CODE:
SUBDIVISION CODE:
***
*** FEE SUMMARY ***
Total Valuation
Plan Review Fee
Use Tax
Permit Fee
** TOTAL **
*** COMMENTS ***
060125 Complete Basement Systems
UA / Unassigned USE: UA / Unassigned
2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
ESTIMATED PROJECT VALUATION:
FEES
0.00
112.19
157.50
172.60
442.29
7,500.00
*** CONDITIONS ***
Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
Engineer's wet -signed and stamped observation letter required for final.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that Ian le ally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be
pei Tied is disclosed in this document and/or i�s' accompanying approved plans and specifications.
l�J
Signature ofVWNER or CONTRAic'>:iM (Circle one) Date I
I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, poli -cies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original�ppermit fee.
3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit ho der shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for or an approval of, any violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of
Wheat Rj,dge
COMMUNITY DEVELOPMENT
Building & Inspection Services Division
7500 W. 291" Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: perm its(a)ci.wheatridge.co.us
FOR OFFICE USE ONLY
Date:
I�11
Plan/Permit # �l\!✓ ��� I �,
I
Plan Review Fee:
M ",
Building Permit Application
Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ***
Property Address: 12376 W 34th PI
Property Owner (please print): Garrett Jones Phone: 303-437-7292
Property Owner Email:_ garrett(a_jdipro. com
Mailing Address: (if different than property address)
Address:
City, State, Zip:
Architect/Engineer: DL Engineering
Arch itect/E ng 1 neer E-mail: gtownsend(a_dlengineer.com Phone
Contractor: Rod Martin's Complete Basement Systems
Contractors City License #: 60125
720-440-9450
Phone: 303-805-8751
Contractor E-mail Address: kayla.montez(a),completebasementsystems.net
For Plan Review Questions & Comments (please print):
CONTACT NAME (please print): Kayla Montez Phone: 303-805-8751
CONTACT EMAI L(p/ease print): kayla.montez(a)-completebasementsystems.net
Sub Contractors:
Electrical:
W.R. City License #
Other City Licensed Sub:
City License #
City License #
Plumbing:
W.R. City License #
Other City Licensed Sub:
Mechanical:
W.R. City License #
Complete all information on BOTH sides of this form
❑ COMMERCIAL 2 RESIDENTIAL
Description of work: (Check all that apply)
❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE
❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING
❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING
❑
RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT
❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT
❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
+BOTHER (Describe) Foundation Stabilization
(For ALL projects, please provide a detailed description of work to be performed, including current use of areas,
proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and
amount of materials to be used, etc.)
Sq. Ft./LF Btu's
Amps
Squares
Gallons
Other
Project Value: (Contract value or the cost of all materials and labor included in the entire project)
$ 7,500
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the
truthfulness of the information provided on the application.
CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)
Signature (first and last name): iVu&.A/W4 DATE: 01/10/2018
DEPARTMENT USE ONLY
ZONING COMMMENTS: OCCUPANCY CLASSIFICATION:
Reviewer:
BUILDING DEPARTMENT COMMENTS:
Reviewer:
►ll�l�
Building Division Valuation: $
1/9/2018
RE: Job# 2017-3828
12376 W. 34th Place
Wheat Ridge, CO 80033
OL ENGINEERING. INC
2150S W40SWORINOENO.SOtl( 0-253
OEM ?. [500227
720-440-5455
As requested, a site visit and observation was performed at the property located at the address
above on January 9, 2018 at approximately 9:00 a.m by Matt Weber, PE. The purpose for the
site visit and observation was to review the structure for movement of the foundation.
The subject property is a single family home with a finished basement located in an established
neighborhood. The house is assumed to be built in 1962 (based on an online search of the
Jefferson County Assessors records).
The foundation is constructed of concrete and is assumed to be on spread footings. The house
appears to be constructed of wood with an exterior brick veneer. The observation was visual
and limited to the exterior and the interior of the home. No observation was performed on the
roof structure. In addition, there were no structural or architectural plans available for review at
the time of observation. For purposes of this report we assume that the home faces north.
Observations
• Horizontal and diagonal cracks in south basement foundation wall.
• Vertical cracks in exterior concrete foundation stem wall.
• Brick veneer overhangs stem wall approximately 1 %' on the south wall.
• Inadequate gutter downspout extensions.
• Crack in drywall above door in garage.
• Stepping cracks in exterior brick veneer above door in garage.
• Separation of exterior brick veneer of garage and house.
Recommendations
The cracks observed in the walls were likely caused by lateral and vertical movement of the
foundation. These movements are most likely caused by contraction and expansion of the soil
due to changing moisture content. The solution is to drain water away from the house and
prevent it from infiltrating the soil next to the foundation. The following is a list of
recommended repairs that should be made to stabilize the foundation:
• Install approximately (10) wall anchors along thq-t64th basen-W-R `fHoundation wall to
mitigate lateral movement. Wh6k
• Install adequate gutter downspout extensions.'14R:Om>o�
• Monitor the garage for additional settlement. Future hA.,",,p'1f3Mbe required to
mitigate further vertical movement. ftWotMed for Code Comolian
• Patch and monitor cracks in concrete foundation w—aIT-5n-a1 P v�rre'2r! fftrp
movement is observed, contact DL Engineering Inc. for ficolete
assessment.
• With any foundation movement, the only way o s estability "s fully
underpin the entire foundation. This observa areas d a ear to
be actively moving. vE r.mMee �u
--..:•`$ �,�%�; tie nwoncr oJo a+mu o: avao.vs' 01 plonc s!>K+Rco4lans
City of `a� "~00A'",eaan¢rbeave+ma/a wo�ooafo„,rM.m+rot+w�ro 1
wK��Sses •/� bWJ�g code a Mont City «dboren,. Arrmip
wheat J3i� eeve,<«*me W" of ineotisftmo be vow
9e � -� �`5 WET
wilding Divi'111san ��t1i1n1 I��.��-
/�r� OL ENGINEERING. INC.
21585 WAOSWDi1H8W6.S61lE6.263
OFNVF& co 807
720-440-8458
General Information: Site Drainage
The moisture around foundation elements must be controlled for the useful life of the
building. Lack of proper drainage is often a contributing factor to foundation damage
observed. The site drainage around the structure must be maintained such that
precipitations will quickly drain away. The use of proper slope slabs -on -grade, moisture
barriers, swales, and surface/subsurface drainage systems are strongly recommended.
Extensions should be attached to properly functioning downspouts and roof drains such
that they discharge a minimum of 10 feet away from the structure.
General Information: Site Vegetation
The vegetation around the perimeter of the structure can eventually lead to foundation
movements. Vegetation can hold moisture in soil and create excessive pressure on the
foundation system. In order to reduce the risk, bushes, shrubs, and trees should be
carefully removed by an experienced professional. Care should be taken to not further
disturb or damage the existing foundation system.
Planters and other surface features which could retain water should be eliminated and
properly graded to reduce the possibility of moisture infiltrating around the foundation.
Figure 1: Diagonal crack in south basement foundation wall
City of
"Oat Ridge
OL ENGINEERING. INC.
r,.._ ,E LLrl - P _ =e.i Q!—L
2150S WADSWORTH RIV91111118-293
BEAVER co 88227
728-440-9458
GLr-�t 4N Ei2�1
Figure 2: Horizontal crack in south basement foundation wall
Figure 3: Brick veneer overhangs stem wall by approximately 1 ':" at center of south wall
City of
Wheat Ridge 1 3
uilding Diaison
"0 -7
ww=
4&;Pb OL ENGINEERING. INC.
2750S WADSWORTROD SMI t 203
DEAVEP, 00 88227
720-41-9459
Figure 4: Vertical crack in exterior foundation stem wall
IL I
Figure 5: Inadequate gutter downspout extension
City of
Wheat Ridge
uilding
OL ENGINEERING, INC.
1TFiu
— _ r L P-= FMV3 Uwr,L r r .Er EIC Erarl•'Fr--
2750S
cr--21505 WADSWORTHOLVD,S8i1F 0-203
014VFR. U80227
720.440-9450
Figure 6: Crack in drywall at garage door
Figure 7: Stepping crack in brick veneer at garage door
City of
Wheat Ridge
wilding Qiviso
DL ENGINEERING. INC.
=RUC -JRA: ENZW4EEP—Ci ?P.O�_'�-., �tiJ`�1L F'f_RErr54-cNCIv�EFe',+�
2750 $. WA0MTH 8LVD S$llE 0 203
0E40. Cl $0227
720-443-DOI
c ,,1 11EEF-.-
Figure 8: Stepping crack in brick veneer at garage door
Figure 9: Separation of garage and house veneer
City of
Wheat Ridge
uilding Diviso
;mm"P-m CIL ENGINEERING. INC.
':T"UCTDR-- CNZtjFEPING .
2150S whos"TH BLVD SWIE 8213
OINVIR. 388227
729-440-5450
Figure 10: Back of house
Figure 11: Back of house
City of
Wheat Ridge ) 7
uilding
� DL ENGINEERING. INC.
`=TRIJCTJF..'.r .N tl+J[F_RI'JG PRIG �P.;1�•JlL i'6AE'ac:0.= CNCL'JECA.t,„:..
2750S wAoswORtN ALv65611E 0-267
0111M. c660227
72x440-6450
Figure 12: Front of house
In as much as the site review of an existing structure for the purpose of observing the structure
conditions requires that certain assumptions be made regarding existing conditions and because
some of these assumptions may not be verifiable without expending additional sums of money
or destroying otherwise adequate or serviceable portions of the building, the Client agrees that,
except for negligence on the part of the Engineer, the Client will hold harmless, indemnify and
defend Engineer from and against any and all claims arising out of the professional services we
have provided.
If you should have any further questions, please feel free to contact me at (720) 440-9450 or
mweber@dlengineer.com.
Sincerely,
Matt Weber, PE
Under the direct supervision of,
Garrett Townsend, PE
,ity of
Wheat Ridge g
Building Divison
DL ENGINEERING INC.
2750 S. WADSWORTH BLVD.
FOUNDATION STABILIZATION AT
DATE:
1-9-2018
JOB#:
2017-3828
REVISION DATE:
PAGE
OF
1
UNIT 0-203
12376 W. 34TH PLACE
DENVER, CO 80227
WHEAT RIDGE, CO 80033
S1.1
5
BY:
CHECKED BY
720-440-9450
OWNER: JONES
WWW.DLENGINEER.COM
MW
GT
INDEX:
S1-1 GENERAL NOTES
S1-2 GENERAL NOTES
S1-3 GENERAL NOTES/ LEGEND
S2-1 FOUNDATION PLAN
S3-1 TYP. WALL ANCHOR DETAIL
BUILDER INFORMATION:
Complete Basement Systems of CO
11795 East 45th Ave
Denver, CO 80239
1-303-219-7646
General Notes:
1. Construction documents are valid for a single use at the project location and shall not be reused, copied, or reproduced
without written approval of the registered design professional in reasonable charge.
2. The contractor is responsible for the methods, means and sequence of all structural erection except when specifically noted
otherwise in the construction documents. The contractor shall provide temporary shoring and bracing, providing adequate vertical
and lateral support during erection. Shoring and bracing shall remain in place until all permanent members are placed and all final
connections are completed.
3. The contractor agrees that, in accordance with generally accepted construction practices, the contractor will be required to
assume sole and complete responsibility for job site conditions during the course of construction of the project, including safety of
all persons and property. This requirement shall be made to apply continuously and not be limited to normal working hours. The
contractor further agrees to defend, indemnify and hold owner and engineer harmless from any and all liability, real or alleged, in
connection with the performance of work on this project, exempting liability arising from the sole negligence of engineer.
4. All existing sizes, dimensions and foundation damage shall be field verified by the contractor and owner prior to
construction. Discrepancies with the construction documents shall be reported to the structural engineer for additional
recommendations (if any).
5. Per the owner's request, the contractor shall stabilize the structure only. No attempt shall be made to lift or plumb the
foundation wall without approval for the owner and structural engineer.
Field Verification:
1. Contractor and Owner shall thoroughly inspect and survey existing structure to verify dimensions, elevations, framing, etc.
which affect the work shown on the drawings.
2. Report any variation or discrepancies to the structural engineer before work proceeding.
Foundation Design:
1. Soil conditions and types shall be verified by a Geotechnical Engineer during excavation.
2. Follow all recommendations of the Geotechnical Engineer for foundation elements.
3. All helical piles, push piers, helical anchor tiebacks, wall anchor tiebacks and connection hardware shall be designed and
installed by supplier, such that they provide the minimum allowable capacities as indicated on the drawings. All capacities shown
on the drawings are unfactored service loads and have not been reduced for live load reductions.
4. All steel for helical piles, push piers, helical anchors tiebacks, wall anchor tiebacks and
connection hardware s_haJI be hot dip galvanized.
5. Design of indi\4 �{%i�h3f o ti s based on a maximum allowable bearing pressure of 2000 lbs. per square
foot (dead load plus f e I� undisturbed soil, or compacted structural fill below frost depth.
Design Building
Criteria: Sp 1Qgyw y g
1. Buildin code: 2012 1B 1 wl Cit of Wheat Ridge Amendments
2. Dead loads ,Revie„�edfor Cod! COM111409S
2.1. Roof 12psf
2.2. Floor 10psf
2.3. Walls ,�
l psf .i Date
3. Live loads
3.1. Residential
3.2. Roof 20psf '
'. .r isswrlce oJa pem,R a oppoval of pions svedlaorions
4. Snow loads 1Weravt"ahcaonovwoIQIof, a Wobtionto
4.1. Roof snow load 30 psf the tsrwldnpcc* a,ofa owwdiw-m.A,—itsCHt of5. Wind loads O toviobreol`°n nowo"iskmq/ow#Lwav y
es of the City "FW be VOW.
5.1 Exposure Category C Wheat R;,Iq'-i
5.2 105 mph 3 -sec gust1CP i+3•bll �
Building Divi
DL ENGINEERING INC.
2750 S. WADSWORTH BLVD.1-9-2018
FOUNDATION STABILIZATION AT
DATE:
JOB#:
2017-3828
REVISION DATE:
PAGE
OF
UNIT 0-203
12376 W. 34TH PLACE
DENVER, CO 80227
720-440-9450
WHEAT RIDGE, CO 80033
OWNER: JONES
--
S1-2
5
BY:
CHECKED BY:
WWW.DLENGINEER.COM
MW
GT
Cast -in -Place Concrete
1. All concrete design is based on the "Building Code requirements for Reinforced Concrete" (ACI 318-05/318R-05)
All structural concrete shall have a minimum 28 -day compressive strength as follows:
1.1 Footings:3,000psi
1.2 Slab on Grade: 3,500psi
1.3 Foundation walls: 3,000psi
2. Concrete shall be placed on proportioned utilizing Type 1 cement except, concrete exposed directly to soil shall use Type 2
cement. Concrete susceptible to freeze shall be formulated or maximum frost resistance in accordance with the ACI
manual of Concrete Practice.
3. Cold weather and or hot weather placing procedures shall be provided, if conditions warrant, as recommended in the ACI
manual of Concrete practice.
Reinforcing Steel:
1. All detailing, fabrication, and placement of reinforcing steel shall be in accordance with the ACI Manual of Concrete Practice.
2. Reinforcing bars shall conform to ASTM A615-79 and shall be grade 60.
3. Except as noted on the drawings, minimum concrete protection for reinforcing shall be in accordance with ACI
318-05/318R-05.
4. No. 5 or larger reinforcing bars shall not be re-bent.
5. Welding of rebar is not permitted unless procedure is approved by the Structural Engineer.
Structural Steel:
1. Structural Steel shall be detailed, fabricated and erected in accordance with 2010 AISC Specification for Structural Steel
Buildings, and "Code of Standard Practices" 2005.
2. Structural Steel shall be confirmed to the following grades:
2.1 W- & WT- Shapes: ASTM A36, A992
2.2 Plates & Angles: A36
2.3 HSS: ASTM A500 gr B
2.4 Steel Pipe: ASTM A53 gr B
3. All bolts shall conform to the ASTM A325 except anchor bolts which shall conform to ASTM A307. Bolt Size shall be
3/4", unless noted otherwise on the drawings.
4. All welding shall be by a certified welder in accordance with ACIS and AWS specifications and recommendation.
Structural Wood framing:
1. Except where noted otherwise, all 2" members shall be Hem -Fir No. 2 and better.
2. Except as noted otherwise, minimum nailing shall be provided as specified in Table No 2304.9.1 "Fastening Schedule" of
the IBC. All nails shall be common type, unless noted otherwise.
3. Unless noted otherwise, steel connectors such as those manufactured by Simpson Company, shall be used to join rafters,
trusses, joists, or beams to other members at flush -framed conditions. Use maximum number and size of nails indicated in
manufactures tables U.N.O. all nails holes shall be filled.
4. All multiple members shall be glued & nailed together.
5. All wood in contact with concrete or exposed to weather, shall be pressure treated Douglas Fir -Larch No. 2 or equal.
6. Structural members shall not be cut for pipes, etc. Unless specifically noted or detailed.
Periodic surveys:
1. Periodic surveys of the supported structures should be conducted to assure project success. The Owner should be
responsible for annual surveys certifying project success. We would suggest that a
baseline survey be conducted immediately. The owner shall submit all findings and
reports to the Structural Engineer.
2. If vertical movement of the piers is discovered, the piers should be
re -pressured. A representative of the Geotechnical Engineer should be present to
observe the re -pressuring. A final report should be provided by the Geotechnical
Engineer after observing the re -pressuring.
Foundation Stabilization:
1. Although observed foundation damage typically does not pose an immediate City of
health and hazard risk, delaying mitigation will likely make future repairs more difficult
and costly. Furthermore, it has been our experience that once a structure beginsWheat Ridge
moving, it will likely continue to so (unless action is taken) resulting in further settling,�
Diviso
DL ENGINEERING INC.
DATE:
JOB#:
2750 S. WADSWORTH BLVD.
FOUNDATION STABILIZATION AT
1-9-2018
2017-3828
REVISION DATE:
PAGE
OF
UNIT D-203
12376 W. 34TH PLACE
DENVER, CO 80227
720-440-9450
WWW.DLENGINEER.COM
WHEAT RIDGE, CO 80033
OWNER: JONES
----
S1-3
5
BY
MW
CHECKED BY:
GT
neavmg, unsightly cracks, doors/widows not functioning properly and possible foundation wall collapse. The extent and
aggressiveness of the foundation repairs should be carefully considered by the Owner and will depend on their tolerance for risk,
the possibility of future damage, and cost.
2. If the owner chooses to do so the foundation could be stabilized only at visibly damaged locations and areas where
movement is concentrated. Although this will address specific situations, it is possible that foundation movements will occur
elsewhere.
3. If the Owner chooses to do so, the entire foundation could be mitigated. A general system repair, although more costly,
would greatly reduce the risk of future foundation damage and movement. It is our understanding that the Owner would not
like to pursue this repair option.
Site Drainage
1. We believe that the moisture around foundation elements must be controlled for the useful life of the building. Lack of
proper drainage is often a contributing factor to foundation damage observed. It is our opinion that site drainage around the
structure must be maintained such that precipitations will quickly drain away. The use of proper slope slabs -on -grade, moisture
barriers, swales and surface/subsurface drainage systems are strongly recommended. Extension should be attached to
properly function downspouts and roof drains discharge a minimum of 10 feet away from the structure.
Site vegetation
1. We believe that vegetation around the perimeter of structures can eventually lead to foundation movements. Vegetation
can hold moisture in soil and create excessive pressure on the foundation system. In order to reduce the risk, bushes, shrubs and
trees should be carefully removed by an experienced professional. Care should be taken to not further disturb or damage the
existing foundation system.
2. Planters and other surface features which could retain water should be eliminated and properly graded to reduce the
possibility of moisture infiltrating around the foundation. Irrigation systems and excessive moisture adjacent to structures can
introduce unwanted moisture, possibly resulting in settling and or heaving. The Owner should consider removing irrigation
systems or simply not use them.
Disclaimer:
1. In as much as the site review of an existing structure for the purpose of observing the structure conditions requires that
certain assumptions be made regarding existing conditions and because some of these assumptions may not be verifiable without
expending additional sums of money or destroying otherwise adequate or serviceable portions of the building, the Client agrees
that , except for negligence on the part of the Engineer, the Client will hold harmless, indemnify and defend Engineer from and
against any and all claims arising out of the professional services we have provided.
LEGEND
(E) EXISTING
(N) NEW
PUSH PIER
P.P. #X f— PIER #
(xxxx#)
LOAD ON PIER
WALL ANCHOR
W.A. #x -a---- ANCHOR #
MONO POST
M.P. #x — — POST #
(xxxx#)
�— LOAD ON PIER
HELICAL PIER
H.P. #x "� PIER #
(xxxx#)
_ LOAD ON PIER
City of
-r
t(Wheat Ridge
Building Divison.
DL ENGINEERING INC.
2750 S. WADSWORTH BLVD.1-9-2018
FOUNDATION STABILIZATION AT
DATE:
JOB#:
2017-3828
REVISION DATE:
PAGE
I OF
UNIT D-203
12376 W. 34TH PLACE
DENVER, CO 80227
720-440-9450
WHEAT RIDGE, CO 80033
OWNER: JONES
----
S2-1
5
BY:
CHECKED BY:
WWW.DLENGINEER.COM
MW
GT
�-LUNDATION PLAN
1/16" = 1'-0"
NOTES:
1. SEE SHEETS S1-1 THROUGH S1-3 FOR GENERAL NOTES.
2. INSTALL WALL ANCHORS PER PLAN.
CONCRETE
PATIO
Clay of
�xP1a•3I.1� Wheat Ridge
(Building Divison,
DL ENGINEERING INC.
2750 S. WADSWORTH BLVD.1-9-2018
FOUNDATION STABILIZATION AT
DATE:
JOB#:
2017-3828
REVISION DATE:
PAGE
I OF
UNIT D-203
12376 W. 34TH PLACE
DENVER, CO 80227
720-440-9450
WHEAT RIDGE, CO 80033
OWNER: JONES
----
S3-1
5
BY:
CHECKED BY:
WWW.DLENGINEER.COM
MW
GT
CM
m
!i�
b
a 2'
(E) WALL
(E) FLOOR SYSTEM 12' MIN
SEE PLAN FOR DIM
FIELD VERIFY
T.O. (E) FOOTING
(N) 12x28" WALL PLATE
(N) TENSILE STRENGTH
= 85KS1, 3/4 — 10 UNC 2A,
80" LONG THREADED
ROD ASSEMBLY
COUPLERS YIELD
STRENGTH = 10OKSI
(E) WALL
(N) WALL ANCHOR
ASSEMBLY BY
FOUNDATION
SUPPORT WORKS
(N) 16x26" DOUBLE
PLATE CROSS
PATTERN EARTH
ANCHORS
WALL ANCHOR DETAIL
1 /2" = V-0"
NOTES:
1. HARDWARE TERMINATION SHALL BE
SAE J995 GRADE 2 HEAVY SQUARE
NUTS, %— 10 UNC 2B, OVERSIZED TAP.
2. PLATE STEEL SHALL BE ASTM A1011
C1008—C1010, 10 GAUGE
3. ALL WALL ANCHOR COMPONENTS
SHALL BE HOT—DIP GALVANIZED
r
a
City of
x�to1•i� Wheat Ri�ae
uildiog Diviso
City of Wheat Ridge
Reside Windows/Doors PERMIT - 201708494
PERMIT NO: 201708494 ISSUED: 10/20/2017
JOB ADDRESS: 12376 W 34th PL EXPIRES: 10/20/2018
JOB DESCRIPTION: Residential Window replacement of 21 windows and 1 patio door like for
like and 1 egress window ufactor .31.
*** CONTACTS ***
OWNER (303)973-2621 JDI HOMES INC
SUB (720)855-9000 W. Garrett Jones 130130 JDI Properties
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,000.00
FEES
Window Replacement 50.00
Total Valuation 0.00
Use Tax 84.00
** TOTAL ** 134.00
*** COMMENTS ***
*** CONDITIONS ***
Windows shall comply with all applicable codes, have a .32 or better U -factor and shall be
safety glazing if within a tub enclosure, less than 18 inches above the floor or within 24
inches of a vertical edge of a door.
I by my signature do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as partes to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans an
specifications,
Signature ofV OWNER or CONTRACTOR (Circle one) Date
I. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po Flans
and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original ermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division. ";.:a.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable�� any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
nd--- ___V_ _ aA D
Signature of Chief Building Official V Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of
Wheat j�
�OA
iclge
MUNITY DEVELOPMENT
Building & Inspection Services Division
7500 W. 291h Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: permits(oki.wheatridge.co.us
I FOR OFFICE USE ONLY
Date: 16,12
,/2 ,* } /
Plan/Pe7:0/7,
mit #0/7,
Plan Review Fee:
Building Permit Application
*** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ***
Property Address: 2 S -7 W 3 q
Property Owner (please print): PhoneDz:_�) q 73--Z-GL(
Property Owner Email: q ixrre� to Clovr'l
Mailing Address: (if different than property address)
Address: 5-2, 0 q 6, �L�/ _ s cc t - S' '
City, State, Zip: L i ij (_0 so C Z'o
a-ArcArchitect/Engineer: �j ( /a -
Arch itect/E ngi neer
hitect/Engineer E-mail: V� j Phone:
Contractor: b _T r �= w blkv
Contractors City License #: 130 13 y Phone: QC, S) L/ 7 -7 ct _Z-
Contractor E-mail Address: q c� i - 14" �6 . Loyyt.
Sub Contractors:
Electrical: Plumbing: Mechanical:
W.R. City License # W.R. City License # W.R. City License #
Other City Licensed Sub: Other City Licensed Sub:
City License # City License #
Complete all information on BOTH sides of this form
❑ COMMERCIAL ❑ RESIDENTIAL
Description of work: (Check all that apply)
❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE
❑ NEW RESIDENTIAL STRUCTURE ❑ FINDOW
RCIAL ROOFING
❑ COMMERCIAL ADDITION ❑NTIAL ROOFING
❑ RESDENTIAL ADDITION ®' REPLACEMENT
❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT
❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ OTHER (Describe)
(For ALL projects, please provide a detailed description of work to be performed, including current use of areas,
proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and
amount of materials to be used, etc.)
Sq. Ft.1LF
Amps
Btu's
Squares
evesl
Gallons
Other
Project Value: (Contract value or the cost of all materials and labor included in the entire project)
6LId1✓
O r
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the
truthfulness of the inform a riprovided on the application.
CIRCLE ONE/ (OWNER) (CONTRACT09 or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CON RACTOR)
Signature (first and last name):
ZONING COMMMENTS:
Reviewer:
BUILDING DEPARTMENT COMMENTS:
Reviewer:
DEPARTMENT USE ONLY
DATE.
OCCUPANCY CLASSIFICATION:
Building Division Valuation: $
Sales Person:
F
Dealer Name:
486020 JDI PROPERTIES L L C
Bill To: Ship To:
JDI PROPERTIES L L C - SAME
5204 SOUTH PRESCOTT STREET
LITTLETON, CO 80120
Dealer
Acknowledgement
Quote Date
10/9/2017
Date Ordered
Quote Not Ordered
User Initials: JMC
Quote Created By: asc157 Phone: (720) 855-9000 Fax: 720-855-9090
Order Notes: Delivery Notes: Quote Name: Project Name:
Garrett email Hudson 2 / JDI Properties Hudson 2
QUOTE # RUSH STATUS PO#
1608539 No None
Line Item # Qty Width x Height UI Description Net Price Extended
1-1 1 35 1/2" X 35 1/2" 72 $102.78 $102.78
M
t- --- 35112 ----+
a-- RO - 36 ------ +
A272-70 Series XO 351/2 x 351/2
Frame Width = 35.5, Frame Height = 35.5, Sash Split = Even
Operation / Venting = XO
NFS 1318"
Frame Color = White
Double Glaze, ClimaTech, DS 1 DS
Lock Height = Standard Lock Height
Standard Screen
Ll -Factor = 0.31, CR = 54, SHGC = 0.32, VT = 0,59, CPD =
ASO -A-102-00325-00001
Net Overall
Line Item Notes:
Pricing Detail:
$51.39
1A - Base Price
$26 85
1A - Glazing
S16.67
to -Glass Type
$7.87
1A - Screen Option
Comment/ Room: Weight
None Assigned 35.0
Line Item # Qty Width x Height UI Description Net Price Extended
2-1 1 108" X 59" 167 $323.18 $323.18
1
1�
R0- 12 t2
Comment / Room, Weight
None Assigned 177.0
A273-70 Series XOX 108 x 59
Frame Width = 108, Frame Height = 59, Sash Split = 1/4 -
1/2 -1/4
Operation / Venting = XOX
NFS 13/8"
Frame Color = White
Double Glaze, ClimaTech, DS / DS
Lock Height = Standard Lock Height
Standard Screen
U -Factor = 0.31, CR = 54, SHGC = 0.32, VT = 0.59, CPD =
Aso -A-102-00325-00001
Net Overall
Line Item Notes:
Page 1 Of 4
Pricing Detail:
$75.01
1A - Base Price
$135.20
1A -Glazing
$82.41
1A - Glass Type
$30,56
1A - Screen Option
QUOTE # RUSH STATUS PO#
1608539 No None
Line Item # Qty Width x Height UI Description Net Price Extended
3-1 8 47 1/2" X 351/2" 84 $115.29 $922.32
M
.---- 47 112 —�
►---- RO - 48 -
A272-70 Series XO 47112 x 35 112
Frame Width = 47.5, Frame Height = 35.5, Sash Split = Even
Operation / Venting = XO
NFS 13/8"
Frame Color = White
Double Glaze, CIImaTech, DS / DS
Lock Height= Standard Lock Height
Standard Screen
U -Factor = 0.31, CR = 54, SHGC = 0.32, VT = 0.59, CPO =
ASO -A-102-00325-00001
Net Overall
Line Item Notes:
Pricing Detail:
548 62
1A - ease Price
$36.11
1A - Glazing
$21.76
1A - Glass Type
58.80
1A - Screen Option
Comment / Room: Weight
None Assigned 374.7
Line Item # Qty Width x Height Ul Description Net Price Extended
4-1 1 48" X 24" 72 $94.92 $94.92
�1
Vv
N
it
0
1
48
+---- RD - 48 112
A272-70 Series XO 48 x 24
Frame Width = 48, Frame Height = 24, Sash Split = Even
Operation / Venting = XO
NFS 1 318"
Frame Color = White
Double Glaze, CIImaTech, DS / DS
Lock Height = Standard Lock Height
Standard Screen
U -Factor = 0.31, CR = 54, SHGC = 0.32, VT = 0.59, CPD =
ASO -A-102-00325-00001
Net Overall
Line Item Notes:
Pricing Detail:
$48.15
1A - base Price
$24.08
1A -Glazing
$14.82
1A - Glass Type
$7.87
1A - Screen Oplian
Comment / Room: F Weight
None Assigned 320
Line Item # Qty Width x Height UI Description Net Price Extended
5-1 2 351/2" X 35112" 72 $139.82 $279.64
Be
�— 35112 --+
�-- RO - 36
Comment I Roam: Wei ht
None Assigned 70.0
A272-70 Series XO 35 1/2 x 35 1/2
Frame Width = 35.5, Frame Height = 35.5, Sash Split = Even
Operation / Venting = XO
NFS 13/8"
Frame Color = White
Double Glaze, ClimaTech, Tempered, OBSCURE FULL,
DS/DS
Lock Height = Standard Lock Height
Standard Screen
U -Factor = 0.31, CR = 54, SHGC = 0.32, VT = 0.59, CPD =
ASO -A-102-00325-00001
Net Overall
Line Item Notes:
Page 2 Of 4
Pricing Detail:
$51.39
1A - ease Price
$26.85
IA -Glazing
516.67
1A - Glass Type
$37.04
1A - Tempered
$7.87
1A - Screen Option
QUOTE # RUSH STATUS PO#
1608539 No None
Line Item # Qty Width x Height UI Description Net Price Extended
6-1 6 30 112" X 16" 47
0l i
i 30112 --�
1-- RO - 31 ---+
A272-70 Series XO 30 112 x 16
Frame Width = 30.5, Frame Height = 16, Sash Split = Even
Operation /Venting = XO
NFS 13/8"
Frame Color = White
Double Glaze, ClimaTech, DS / DS
Lock Height = Standard Lock Height
Standard Screen
U -Factor = 0.31, CR = 54, SHGC = 0.32, VT = 0.59, CPD =
ASO -A-102-00325-00001
Net Overall
Line Item Notes:
$80.10 $480.60
Pricing Detail:
S52.32
1A - Base Price
S1343
IA -Glazing
$8,33
iA - Glass Type
$6.02
1A - Screen Option
Comment/ Room: Weight
None Assigned 61.3
Line Item # Qty Width x Height UI Description Net Price Extended
7-1 1 30 1/2" X 16" 47 $98.62 $98.62
01
r-- 3,0112
i- R -31
A272-70 Series XO 30 1/2 x 16
Frame Width = 30.5, Frame Height = 16, Sash Split = Even
Operation / Venting = XO
NFS 13/8"
Frame Calor - White
Double Glaze, ClfmaTech, Tempered, OBSCURE FULL,
DS/DS
Lock Height - Standard Lock Height
Standard Screen
U -Factor = 0.31, CR = 54, SHGC = 0.32, VT = 0.59, GPD =
ASO -A-102-00325-00001
Net Overall
Line Item Notes:
Pricing Detail:
$52.32
1A - Base Price
$13.43
1A - Glazing
S8.33
1A • Glass Type
$18.52
IA - Tempered
$6.02
1A - Screen Option
Comment / Room; Weight
None Assigned 13.6
Line Item # Qty Width x Height Ul Description Net Price Extended
8-1 1 30" X 48" 78 $185.13 $186.13
Comment / Room; 7[77W77;7jg--ht--j
None Assigned 44.0
A682-80 Series Right 30 x 48
Frame Width = 30, Frame Height = 48
Operation / Venting = Right
NFS 1318"
Frame Color = White
Double Glaze, Clima-rech, DS / DS
Egress Hinges
Standard Screen
U -Factor = 0.28. CR = 58, SHGC = 0.26, VT = 0.47, CPD =
ASO -A-107-00136-00001
Net Overall
Line Item Notes: Casement not offered in 70 Series
Page 3 Of 4
Pricing Detail:
$122.70 1A - Base Price
$33.80 1A - Glazing
$18.52 1A - Glass Type
$11.11 1A - Screen Option
QUOTE # RUSH STATUS PO#
1608539 No None
Line Item # Qty Width x Height UI Description Net Price Extended
9-1 1 71 112" X 79 112" 152 $482.46 $482.46
i
i
71 ti
Comment/Room: Weight
None Assigned 165.8
A172 -West Doors XO 71 1/2 x 79 112
Call Width = 72, Call Height = 80, Frame Width = 71.5,
Frame Height = 79.5
Operation / Venting = XO
NFS 1318"
Frame Color = White
Double Glaze, ClimaTech, Tempered, DS / DS
Keyed Lock Tandem Rollers
Standard Screen
U -Factor= 0.3, CR = 51, SHGC = 0.32, VT = 0.6, CPD
ASO -A-98-00052-00001
Net Overall
Line Item Notes:
ATTENTION
Please note that all weights provided are estimates and subject to change based on actual order shipment.
NOTICE: The rating information provided on this quote is based upon the NFRC ratings at the time of quote.
Such ratings are subject to changes in the standard by the applicable regulatory agencies and will be finalized at
the time of manufacturing. All ratings printed on the NFRC label will supersede the NFRC rating set forth in the
quote. Any changes made to an order after submission may also result in changes to the NFRC rating.
Customer shall be solely responsible for determining whether the product ordered meets their jurisdiction's
requirements.
I have reviewed this order and certify that it is correct. I understand that this order is noncancellable,
nonreturnable, and nonrefundable.
By Authorized Representative
Page 4 Of 4
Pricing Detail:
$219.00
1 A - Base Price
S12038
1A -Glazing
$88.90
1A - Glass Type
$43.99
1A - Screen Option
$10.19
1 A - Keyed Lock
Total Unit Count 22
OTAL WEIGHT 993,
SUB -TOTAL:
$2,970.6
SALES TAX:
$0.0
HANDLING:
$0.0
FREIGHT:
$0.0
TOTAL:
$2,970.6
' It City of Wheat Ridge
.� Residential Electric PERMIT - 201706561
PERMIT NO:
201706561
ISSUED:
08/24/2017
JOB ADDRESS:
12376 W 34th PL
EXPIRES:
08/24/2018
JOB DESCRIPTION:
residential electric upgrade
from 100 amp to 200
amp overhead
*** CONTACTS ***
OWNER (303)437-7292
GARRETT JONES
SUB (720)620-7041
Lou Santanostasi
021892 Platinum
Electric Inc.
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE:
UA / Unassigned
SUBDIVISION CODE:
2403 / APPLEWOOD
VILLAGES, PROSPECT V BLOCK/LOT#:
0 /
*** FEE SUMMARY ***
ESTIMATED
PROJECT VALUATION:
1,600.00
FEES
Total Valuation
0.00
Use Tax
33.60
Permit Fee
63.90
** TOTAL **
97.50
*** COMMENTS ***
*** CONDITIONS ***
Work shall comply with 2012 IRC & 2014 NEC. Per IRC Sec. 8314, smoke detectors are required
to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every
level of the structure.Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection.Must
comply w/ 2012 IRC & 2014 NEC. Subject to field inspection.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner o property and authorized to obtain thispermit and perform the work described and approved in conjunction with
this permit. I fu r est that I a l authori -include all entities named within this document as parties to the work to be
per ed an I wor isclosed in this document and/or its' accompan ing approved plans and specifications.
� 02
ilawiture of O R or CONTRACTOR (Circle one) Date
This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and maybe subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to Field inspection.
o
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of
Wheatjj"q'9
COMMUNITY DEVELOPMENT
Building & Inspection Services Division
7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: perm its(a)ci.wheatridge.co.us
FOR OFFI E USE ONLY
Date:/Y0 7
I
Plan/Permit #`;?.617 z�—!S�/
Plan Review Fee: 97 56
Building Permit Application
*** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ***
Property Address: �� �� -2 44 -
Property Owner (please print): 1'011-&E-221' S Phone: ,,3c,2 7 7;z 1z
Property Owner Email:
Mailing Address: (if different than property address)
Address
, State, Z
Architect/Engineer:
Architect/Engineer E-mail:
Contractor:�/
Contractors City License #: D 2 0 l v
Contractor E-mail Address:
Sub Contractors:
Electrical:
W.R. City License #
Other City Licensed Sub:
City License #
Plumbing:
W.R. City License #
Phone:
Phone: 7.2,2
Other City Licensed Sub:
City License #
Mechanical:
W.R. City License #
Complete all information on BOTH sides of this form
❑ COMMERCIAL ❑ RESIDENTIAL
Description of work: (Check all that apply)
❑ NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE
❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING
❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING
❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT
❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT
❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ OTHER (Describe)
(For ALL projects, please provide a detailed description of work to be performed, including current use of areas,
proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and
amount of materials to be used, etc.)
e'41�- sc name-:' i /-? „kv'' 9���t,��
Sq. FtJLF
Btu's
Amps Am Squares
Gallons
Other
Project Value: (Contract value or the cost of all materials and labor included in the entire project)
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the
truthfulness of the information provided on the application.
CIRCLE ONE: (OWNER) (CONTRA OR or (RUTH IZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)
Signature (first and last name): .�-�'� DATE: A G
i
ZONING COMMMENTS:
Reviewer:
BUILDING DEPARTMENT COMMENTS:
Reviewer:
DEPARTMENT USE ONLY
OCCUPANCY CLASSIFICATION:
Building Division Valuation: $
A i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:%y1
Job Address: ?a� (o t .? 3 LIT)4 PL
Permit Number:
❑ No one available for inspectDN
e 1 AM/PM
Re -Inspection required: Yes
When corrections have been made, call for re-inspectionat 303-234-5933
Date: % Inspector: /71 T#
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
_:�9rBuilding Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address: Z
Permit Number: Q/i 4�_576_
I
No one available for inspection: TimeK. 'i"/ AM/PM
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303-234-5933
Date:Inspector: l.%
r"
DO NOT REMOVE THIS NOTICE
INSPECTION RECORD Occupancy/Type
INSPECTION LINE: (303) 234 -5933
Inspections will not be made unless this card is posted on the building site
Call by 3:00 PM to receive inspection the following business day.
INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB
ION INSPECTIONS DATE
INSPECTOR
INITIALS
COMMENTS:
Mechanical
$ION
ete
_h
Building Final
rain
Fire Department
R.O.W & Drainage
INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS
SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS.
Parking & Landscaping
Water Service Lines
FOUR NO UONCRETE UNTIL ABOVE HAS BEEN SIGNED
CONCRETE SLAB FLOOR
Electrical (Underground)
Heating (U
ROUGHS
Sheathing
Lath / Wall tie
Mid -Roof
Electrical Service
Rough Electric
Rough Plumbing
Gas Piping
Rough Mechanical
INSPECTIONS TO
I Drywall Screw I I I
FINALS --
Electrical
Plumbing
Mechanical
Roof
_h
Building Final
Fire Department
R.O.W & Drainage
INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS
SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS.
Parking & Landscaping
"NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING,, BUILDING AND PUBLIC WORKS BEFORE A
CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION
OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY.
I)GGUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED
PROTECT THIS CARD FROM THE WEATHER
♦ i CITY OF WHEAT RIDGE
�� Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office • (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type: Is � L , _f ^
Job Address: I X7376) (V 727 f K
Permit Number: 00t13(Q
ool 'Aeot' is
( ❑ No one available for inspection: Time AM/ CM
Re- Inspection required: Yes No'
'When corrections have been made, call for re-inspection at 303 - 2345933
�. ,' Q AaIF-f P ' Date: Inspector: 1 aC c -x.
`r
DO NOT REMOVE THIS NOTICE -
♦ i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office.. • (303) 237-8929 Fax
INSPECTION NOTICE`
Inspection Type: i5 nt)-
Job Address: 1237 t A r3l/¢t4 r
Permit Number: Lit l( 3f0
❑ No one available for inspectio : Time P36 AM7
Re-Inspection required: Yes ' No
When corrections have been made, call to re-i spe lion at 30,-2345933
Date: 1-00-10 Inspector: a v ,
DO NOT REMOVE THIS NOTICE
~ ~ ♦ (~'it~ of Wheat Rid~rn
W HEgT
City of Wheat Ridge Building Division
7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
COLORPOO Inspection Line: 303-234-5933
Building Permit Application
Date:
Plan
Permit 17~j
Property Address 1 a B70 JVgSS 3.31 ` PI&
Property Owner (please print): 71-om 8111 tj l Phone: w3- 6137" 73T
Mailing Address: (if different than property address)
Address:
State, Zip:
Contractor: 411 .&Ia'VI &0&05
Contractor License
Sub Contractors:
Electrical City License
Company:
a 1 `7 a. Phone:
Plumbing City License
Company
Mechanical City License
Company:
Exp. Date: Exp. Date: Exp. Date:
Approval: Approval:
Approval:
Use of space (description): 90C>f Construction Value: $ ; 044 °
Description of work: (as calculated per the Building Valuation Data sheet)
iAy'pN i-WA % )res~,~n 11e G))'~~t 00, Plan Review (due at time of submittal):
S
r>A4,ri &Jyv, d'Uyh uim~ 110mPH
Sq. Ft.fL.Ftadded: Squares L37 BTU's Gallons Amps
OWNER/ CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide. by all conditions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work
under this permit. Plans subject to field inspection.
CIRLCE ONE:: (OWNER) (ICnO11NTRACTOR) or ONAL REPRESENTATIVE of (OWNER) (CONTRA
PRINT NAME: _ PA.4,hy SIGNATURE:
DEPAi2TIIhEIVT;USE ONLY
ZONING.COMMENTS: -
- -
Zoning:
Reviewer,
-
PUBLIC WORKS COMMENTS
Reviewer"
L~
5
~UILDING')EPARTME 3'COMMENTS
a) r %Tr
'
Oc`etrQA~cf
. ReweAarer
~k ~
s-----~-
~
)f(eDC-PdgTMENT
L~aPProveU V1l cor
p
Bl
v
,
~
nrneti
~IS~r
dg Val
ed RoFeview requT~
=
uation: $