Loading...
HomeMy WebLinkAbout3200 Moore Streets City of Wheat Ridge _ Residential Roofing PERMIT - 201707037 PERMIT NO: 201707037 ISSUED: 09/07/2017 JOB ADDRESS: 3200 Moore ST EXPIRES: 09/57/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles - 29.6 sq Pitch = 5/12 *** CONTACTS *** OWNER MCSHEEHY SHANNON SUB (303)877-7464 Brian Newman 170204 Co Pro Construction *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,607.20 FEES Total Valuation 0.00 Use Tax 159.75 Permit Fee 172.60 ** TOTAL ** 332.35 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. , I u / 0 � 7 jou ���,� � INSPECTION RECORD INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Occupancy/Type 12- Inspections 2 Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Initials Comments Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Plumbing Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Mid -Roof Sewer Service Rough Electric' Plumbing Rough Plumbing/Gas Line Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric' Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Roofing PERMIT - 201707037 PERMIT NO: 201707037 ISSUED: 09/07/2017 JOB ADDRESS: 3200 Moore ST EXPIRES: 09/07/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles - 29.6 sq Pitch = 5/12 10 *** CONTACTS *** OWNER MCSHEEHY SHANNON SUB (303)877-7464 Brian Newman 170204 Co Pro Construction *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,607.20 FEES Total Valuation 0.00 Use Tax 159.75 Permit Fee 172.60 ** TOTAL ** 332.35 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. � A City of Wheat Ridge v Residential Roofing PERMIT - 201707037 PERMIT NO: 201707037 ISSUED: 09/07/2017 JOB ADDRESS: 3200 Moore ST EXPIRES: 09/07/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles - 29.6 sq Pitch = 5/12 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I r attest that I am le ally authorized to include all entities named within this document as parties to the work to be performe d t X11 work to be ormed is disclosed in this document and/or its' accompanying approved plans and specifications. V Signat e of OWNS o ONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuagranting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicabl, co e r any order re l#ti of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Date of loss 4e, // Policy # C l l ' 6/9 l , T Claim # o i �-- 8 i --_� &&,! Insurance Company I t n Adjuster's Name Claim Office *970 —J09 U 4� 3-3 Agreement is contingent upon prior insurance policy carrier or adjuster approval. Agreement amount will be derived from insurer's approved scope and price of loss plus deductible. No work will start u 7 so approved. Customer Initials ` Deductible $ 1006 00- Adjustments $ Contract Total $ -� L -,:IV �n Customer Information Customer Name Address City L c A `- 4k 1DG `- Date7/ ()/ / State Zip E,C-Y-) --- ,53 Email Phone ~� Roof Work Details Shingle Type Drip Edge Color Miscellaneous Adjustments Contract Agreement Shingle Color 'a utter Color 3. $ 4. $ Customer {.�j Name (Print) ��c� f?�V Date Customer Signature If Customer is signing for single owner, joint or common owners, then Customer represents it has authority on behalf of all owners to enter into this Agreement. CoPro Agent Name (Print) 11 —7 e� `�; - L .� �� %�N ���{�- Date 7b-,-111 7 CoPro Agent Signature CoPro Manager Signature of Approval CoPro Construction Services (CoPro) reserves the right to file for supplemental insurance should your insurer's measurements be incorrect or if a price increase is applicable. at no cost to the Customer. Per CoPro, overhead and profit shall be invoiced to your insurance company with the base estimate. This Agreement authorizes CoPro to discuss with your insurer price and scope adjustments and assist in settling your insurance claim for coverage to your property. Ail agreements are subject to Copra Manager's approval. CoPro will not have any verbal agreements, no exceptions, and could decline this Agreement without notice. CoPro will hold in trust any payment from the Customer until CoPro has delivered roof materials at the Address or has performed a majority of the roof work. The pricing offered in this documentation is valid for 15 days from date above. 303.877.7464 1brian@coprocons.com Dane Lovett 1 1/ 070J, From: no-reply@ci.wheatridge.co.us Sent: Wednesday, September 6, 2017 12:38 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Follow Up Flag: Follow up Flag Status: Completed Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) N, 3200 Moore St Shannon Mc Sheehy 303-808-4892 97 n —t- Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract emcsheehy@yahoo.com Yes Contract. pdf CONTRACTOR INFORMATION Contractor Business Co Pro Construction Name Contractor's License 170204 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) 303-877-7464 3440 Sheridan Blvd Denver CO 80212 Contractor Email Address brian@coprocons.com Retype Contractor Email brian@coprocons.com Address DESCRIPTION OF WORK TOTAL SQUARES of 29.6 / the entire scope of work: Project Value (contract q-5tiT' value or cost of ALL materials and labor)l Are you re -decking the No/ roof? 98 Does the scope of the No project include a flat roof (less than 2:12 pitch)? Does the scope of the project include a pitched roof (2:12 or greater pitch)? What is the pitch? How many squares are part of the pitched roof? Describe the roofing materials for the pitched roof: Type of material for the pitched roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) Yes 5:12 _2-9-il- -zqt 6 Asphalt Shingles Asphalt House SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. Yes Yes Yes 99 I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Brian Newman Email not displaying correctly? View it in your browser. 100 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 3 2C.O All 6Oft 5/ ❑ No one available for inspection: Time AM/PM Re -Inspection required: YesNo ,) ..e When corrections have been made, call for re -ins ,ection at 303-234-5933 Date: {� % Inspector: DO NOT REMOVE THIS NOTICE e� i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: /VIj,-`l-) 7)_®e-) M001t? Si ❑ No one available for inspection: Time I / AM/PM Re -Inspection required: YesC)re-ins� ' When corrections have been made,for ection /t 36 -234 - Date: Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax ❑ No one available for inspection: Time AM/PM Re -Inspection required;- Yes' No f �- When corrections have been made, call for re -inspection at 303 -234 - Date: Inspector: DO NOT REMOVE TMIS NOTICE • r- •t • •,•- • • :•, + CITY OF WHEAT RIDGE Building Inspection Division f (303) 234 -5933 Inspection line (303) 235 -2855 Office - (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type PMIC Job Address Permit Number �p { r, ❑ No one available for inspection: Time / A lIfy Re- Inspection required: Yes No When corrections have been made, cal y f r rey spec ion at 303 - 234 -5933 Date: ¢f. f Inspector: DO NOT REMOVE THIS NOTICE w �' .. r CITY OF WE Building Inspc (303) 234 -5933 5933 (303) 235 -2855 OfficE OTICE Inspection Type Job Address Sx I" ze:rp Y '4p_r'1r1e'V" Permit Number OfalS< ❑ No one available for inspection: Time ( Aw'PM Re- Inspection required: Yes" No When corrections have been made, call for re- 'nspection at 303 - 234 -5933 e T XI In Date: spector DO NOT REMOVE THIS NOTICE City of Wheat Ridge 1� Residential Roofing PERMIT - 102151 PERMIT NO: 102151 ISSUED: 09/10/2010 JOB ADDRESS: 3200 MOORE ST EXPIRES: 09/10/2011 DESCRIPTION: Reroof 28 sqs with 30 yr dimensional shingles * ** CONTACTS * ** owner 303/707 -0707 Pirnack Walters sub 303/849 -6202 Chris Herman .,j. 09 -0508 Arrowhead Roofing, LLC ** PARCEL INFO ** ZONE CODE: UA SUBDIVISION: 0647 USE: UA BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 6,580.00 FEES Permit Fee 156.75 Total Valuation .00 Use Tax 118.44 � w ** TOTAL ** 275.19 Conditions: 6 nails per shingle is required. Ice dam membrane is required from eave edge to 2' inside exterior walls. Board sheathing with any gap greater than 1/2" requires panel sheathing overlay on entire roof. Sheathing inspection is required prior to covering. Midroof inspection is not required on permits purchased after 4/18/10. Contractor shall provide ladder for inspections. Scheduled inspections that cannot be performed due to inclement weather must be cancelled prior to 8:30 a.m. on the day of inspection or a re- inspection fee will be assessed. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Whga E'Ridge for work under this permit. Plans subject to field inspection. Signature 6f contracto /owner date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. S. Contractor shall notify the Building Inspector twenty -four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval o , any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All ev is subject to field inspections. Signat e ofV Building Official date INSPECTION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ( ' u< 4 t< a� .iil�tl� LiE�,flr7ptkkih73`"`' Klan x` Building 8 Inspection Services Division Pei" - 1 �jiZ' ii 1 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303 -235 -2855 . Fax' 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application Property Address 3a�0 yf ST Property Owner (please print): Mailing Address: (if different than property address) Address: City, State, Zip: CcinCractoti: Contractors City License #c Phone: SD3 -2 Z� -& ;w" 5upPontracfiors: Electrical: Plumbing: Mechanical: City License # City License # City License #, 1C�escriis�ie�n x�fi +atrt�rit Conti ct Value 1vrsTr�LL3D 4fcD %s�6y1�0 $ c2 l��2iTr�3U (�nyr�vclo��� SfEs. Review Fee (due at time of submittal). Squares / BTU's Gallons Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit . application are accurate and do not violate applicable ordinances, . rules or regulations . of the City of Wheat Ridge or covenants, easements . or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full :responsibility for compliance with applicable City of Wheat. Ridge codes and ordinances for work under any permit issued based on this application; that 1 am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. - CIRCLE ONE.' (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE of (OWNER) (CONTRACTOR) PRINT NAME: / /Z�/'///� SIGNATURE: j GATE: �ID - ID DEP�2TM1:�7 Us���II:Y S Y ` Bldg Valuation: CERTIFICATE OF COMPLETION City of Wheat Ridge 7500 W 29th Ave Wheat Ridge CO 80033 Permit# 101267 Stipulations: Issued: 09/08/10 Kitchen Cabinets and Minor Interior Wall Modification This certificate verifies that the building constructed and/ or the use proposed of the building and /or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code and development standards of the zone district in which it is located and may be occupied. All other licensing requirements for the City must be met. Site Address: 3200 MOORE ST Parcel Number: 39- 281 -15 -030 Owner: PWE Residential LLC 7323 S. Alton Way, Unit A Centennial, CO 80112 Contractor: Brian White Rinack Walters Enterprises 7323 S. Alton Wy. Unit A Centennial, CO 80112 -2310 For the Following Pu Code Editions 2006 ICC /2008 NEC 2V6 ICC /2005 NEC 3 ICC /2005 NEC — Sprinkler System rpose: Residential Remodel NO change shall be made in the USE of this building without prior notice and a new Certificate of Completion from the City of Wheat Ridge. spector Zoning Administrator CERTIFICATE MUST BE POSTED BY FRONT DOOR OF COMMERCIAL OCCUPANCIES 09/08/10 16:40:32 City of Wheat Ridge Page 1 bp701 -1s PERMIT INFORMATION - 101267 mmackey PERMIT INFORMATION: Permit#; 101269 Address: 3200 MOORE ST Permit Type: Residential Remodel Parcel Cd: 39- 281 -15 -030 Permit Ot: 05/17/2010 OWNER: PWE Residential LLC Expires: 11/13/2010 Address: 7323 S. Alton Way, Unit A City /St /Zip: Centennial, CO 80112 LAND PARCEL INFORMATION: Zone Cd: Unassigned DU: 1 SetBacks- Front: 0.0 Faust Use: Unassigned Last Zone Dt: Left: 0.0 Subdivision: ROLLING HILLS ELKS 6 Annex Dt: Right: 0.0 Cott Type: Miscellaneous Lot: Black No: 0 Hack: 0.0 Legal: JOE DESCRIPTION: Kitchen cabinet & minor interior wall modification. FEES QTY DUE PAID: Permit Fee 59,146.60 927.95 927.95 Plan Review Fee .00 603.17 603.17 Total Valuation 59,146.60 .00 .00 Use Tax 59,146.60 1,064.64 1,064.64 ---------- 2,595.76 --- - - - - -- 2,595.76 CONTACTS: owner PWE Residential LLC 7323 S. Alton Way, Unit A Centennial, CO 80112 3037070770 go CL2 Rinack Walters Enterprises Brian White 7323 S. Alton Wy. Unit A Centennial, CO 80112 -2310 3037070770 sub CIA Ruby Electric, Inc. Wayne Kimmel 13192 Birch Way Thornton, CO 80241 3038989658 sub CL8 Lee Huddleston Plumbing, Inc. Edward L. Jones 3195 Oakland St Aurora, CO 80010 3033647536 PARCEL INFORMATION: 10 Structure Type SP -L 20 Year Built 1958 30 Property Type RESID PERMIT CONDITIONS: RP: Must comply w/ 2003 IRC & 2005 NEC. Subject to field inspections. Engineer's letter of approval needed at time of final inspection for any alterations to load bearing walls. The issuance of a building permit should not be construed to be approval of a business license. Smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. Carbon Monoxide detectors are required to be installed within fifteen (15) feet outside the entrance to each sleeping room. Tempered glazing is required within 24 inches of doors, in tub enclosures, and as required by code. Replacement windows shall have a U- factor of .35 or less. Inspection prior to covering is required. APPROVALS REQUIRED INSPECTIONS STATUS: PERMIT NOTES 09/08/10 16:40:32 City of Wheat Ridge Page 2 bp701 -1s PERMIT INFORMATION - 101267 mmackey 05/17/10 ks; Given to RP for review. COMPLETE 07/06/10 COMPLETE 07/08/10 05/17/10 CREATED FROM APPL# 10 -0176 07/12/10 COMPLETE 07/16/10 COMPLETE INSPECTION INFORMATION: COMPLETE 09/08/10 COMPLETE 09/08/10 COMPLETE # TYPE CONTR# CALLED ONCE WHO REQ DT 1 pug:Plumbing Underground 10 -0133 07/02/10 no my 07/06/10 2 eri:Electrical Rough Ins 10 -0186 07/02/10 no my 07/06/10 3 fri:Framing Rough Insp. 10 -0133 07/07/10 no kc 07/08/10 4 pri:Plumbing Rough Insp. 01 -9972 07/09/10 no kc 07/12/10 5 fri:Framing Rough Insp. 10 -0133 07/09/10 no kc 07/12/10 6 dws:Drywall screw /nail 10 -0133 07/15/10 no MV 07/16/10 7 EFI:Electrical Final Ins 10 -0186 09/07/10 no MV 09/08/10 8 PFI:Plumbing Final Insp 01 -9972 09/07/10 no KC 09/08/10 9 BFI:BUilding Final Insp 10 -0133 09/07/10 no KC 09/08/10 10 EMR:Elec Service - EMR 10 -0186 09/08/10 no MV 09/08/10 11 MFI:Mechanical Final 09/08/10 no KC 09/08/10 INS DT STATOS 07/06/10 COMPLETE 07/06/10 COMPLETE 07/08/10 INCOMPLETE 07/12/10 COMPLETE 07/12/10 COMPLETE 07/16/10 COMPLETE 09/08/10 COMPLETE 09/08/10 COMPLETE 09/08/10 COMPLETE 09/08/10 COMPLETE 09/08/10 COMPLETE ♦ A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: 05. ,d Allmo ", 13� Job Address: _ V00 � ,eg 5 it Permit Number: 7 1 ❑ No one aval� , AM P� Re- Inspection re, res <No) `When corrections have been made, call for re -inspection at 303 -234 -5933 Date: T s? 10 Inspector: T DO NOT REMOVE THIS NOTICE INSPECTION RECORD Occupancy /Type INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. 4 I r7 i 5 m1�n C INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR COMMENTS: INITIALS Footings /Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines POUR NO CONCRETE UNTIL ABOVE HAS BEEN $IC.NFn CONCRETE SLAB FLOOR Heating (Undergrou p l tie ervice ctric bing Gas Piping Rough Mechanical Framing �� -yL� - rRVIiCCU1lYU Insulation 'r ,sic¢- Mechanical c�a 3fa .eLG . Drywall Screw �. Building Final FINALS Electrical lj Plumbing Mechanical c�a 3fa .eLG Roof Building Final Fire Department - R.O.W & Drainage - Parking & Landscaping INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEE PR IOR TO FI INSPECTION „_ "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. vL ;UFANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER INSPECTION RECORD o ccupancy /Type ' INSPECTION LINE: (303)234 -5933 i OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER Inspections will not be made unless this card is posted on the building site Call a by 3:00 PM to receive inspection the following business day. n Sheathing I I o / INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS:" Footings /Caissons Stemwall / (CEG) Concrete Encased Ground - Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR Electrical (Underground) - Insulation Plumbing (Underground) Drywall Screw Heating (Underground) ROUGHS Sheathing Lath / Wall tie Mid -Roof Electrical Service Rough Electric Rough Plumbing Gas Piping - Rough Mechanical ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING Framing - Insulation Drywall Screw FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping ' "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A .'CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION &A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. ♦ 41 CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 7 Permit Number: ❑ No one available for inspection: Time AM Re- Inspection required: Yes When corrections have been made, call for re inspection at 303 234 - 5933 Date: Inspector: DO NOT REMOVE THIS NOTICE , CIF ♦ i CITY OF WHEAT RIDGE �-j► Building Inspection Division (303) 234 -5933 Inspection line // (303) 235 -2855 Office • (303) 237 -8929 Fax ,7 �,,,41- INSPECTION NOTICE Inspection Type: -7 Job Address: X&0 /Z Permit Number: //) 0 0 / ❑ No one available for inspection: Time AM /PM Re- Inspection required: Yes N "When corrections have been Date: 3' Inspector: s - DO NOT REMOV action at 303 -234 -5933 Citv of Wheat Ridge ZCEL .INFO ** USE: <UA UBDIVISION:, 0647 :!BLOCK /LOT #: 0./ * FEE SUMMARY ** ESTIMATED PROJECT VALUATION: .00 Investigative Fees 35.00�� 1(-� Gl3�p�`. Permit Fee :35.00 ��,= * *',TOTAL * *S 70.00 onditions::c ees! doubled for doing work without a permit. P: Approved. Zoned R 1. Subject to field inspection. ote: Owner /Contractor is responsible for locating proeprty lines and onstructing- 'improvements according to the approved plan and required =_velopment standards. The City is not responsible for inaccurate information ubmi:tted within the plan set and any construction errors resulting from aaccurate information. hereby certify: that the setback distances proposed by this permit :application: are accurate, and do not violate applicable rdinances, rules or regulations of the City of .Wheat Ridge or covenants, easements or restrictions of record; that all ,easurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this pplicati and I assume full responsibility for compliance with the Wheat Ridge Building Code `(I B.C) and all other.': pplicablfor work under this p� a subject to field inspection. ignatu otza dt wn er Cdate This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat :Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire 180 days from the issue date. Requests for an extension must be received :prior to expiration date. An extension may !be granted': at' the discretion of the Building Official. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. 'If changes :. have been or if suspension or abandonment ':. exceeds one (1) year, full fees shall be paid for anew permit:. No work of any manner shall be done that will change the natural flow of water causing (a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive l: written approval on inspection card before proceeding with successive phases of the job. The issuance of a permit: or the approval of drawings and specifications shall not be construed to be a permit for, nor an ;approval of, any violation of the provisions of the building codes or any'. other ordinance, law, rule or regulation. All plan review is subject to field inspections gnat l ief Building Official :date 1S CT N REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235-2855 acme nmrem no Henna ov ". t PERMIT NO: :101803.: ISSUED: 07/20/2010 JOB - ADDRESS: I'3200 <MOORE ST ;..EXPIRES: 07/20/2011 W; DESCRIPTION: Permitting for fence that was installed previous to new H/0 - * ** CONTACTS * ** r' owner 303/707-0770 PWEt Residential LLC - sub -: 303/707-0770 Brian White 10 -0133 Rinack Walters Enterprises'. ZCEL .INFO ** USE: <UA UBDIVISION:, 0647 :!BLOCK /LOT #: 0./ * FEE SUMMARY ** ESTIMATED PROJECT VALUATION: .00 Investigative Fees 35.00�� 1(-� Gl3�p�`. Permit Fee :35.00 ��,= * *',TOTAL * *S 70.00 onditions::c ees! doubled for doing work without a permit. P: Approved. Zoned R 1. Subject to field inspection. ote: Owner /Contractor is responsible for locating proeprty lines and onstructing- 'improvements according to the approved plan and required =_velopment standards. The City is not responsible for inaccurate information ubmi:tted within the plan set and any construction errors resulting from aaccurate information. hereby certify: that the setback distances proposed by this permit :application: are accurate, and do not violate applicable rdinances, rules or regulations of the City of .Wheat Ridge or covenants, easements or restrictions of record; that all ,easurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this pplicati and I assume full responsibility for compliance with the Wheat Ridge Building Code `(I B.C) and all other.': pplicablfor work under this p� a subject to field inspection. ignatu otza dt wn er Cdate This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat :Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire 180 days from the issue date. Requests for an extension must be received :prior to expiration date. An extension may !be granted': at' the discretion of the Building Official. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. 'If changes :. have been or if suspension or abandonment ':. exceeds one (1) year, full fees shall be paid for anew permit:. No work of any manner shall be done that will change the natural flow of water causing (a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive l: written approval on inspection card before proceeding with successive phases of the job. The issuance of a permit: or the approval of drawings and specifications shall not be construed to be a permit for, nor an ;approval of, any violation of the provisions of the building codes or any'. other ordinance, law, rule or regulation. All plan review is subject to field inspections gnat l ief Building Official :date 1S CT N REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235-2855 acme nmrem no Henna ov ". ♦ City of Wheat -Midge COMMUNITY DEVELOPMENT Date: Plan # I C 2 Building & Inspection Services Division Permit # 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application ��� aie s 3200 Moore Street, Wheat Ridge, CO Property owner (please print): PWE Residential LLC Phone: 303.707.0770 Mailing Address: (if different than property address) Address: 7323 S Alton Way, Unit A City, state, zip: Centennial, CO 80112 - M il li Contractors City License #: 'fOT 1 1 1 1 Electrical. n/a Plumbing: n/a City License # City License # fence permit. There is no contract value as the fence is already built. quares BTU's Gallons Amps SgFt Mechanical: II/a City License # Contract Value: 0 s Review Fee (due -pt time of submittal): ��1 ek� OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER N RACTOR) Brian White July 15, 2010 PRINT NAME: Brian DATE: , i Eyr ap rto: odot>J.!£5e.0 .F u,,.ls._...rp,e...ore , iE .t.Pi._ Bldg Valuation: $ $ No City of `(� Wheat idge COMMUNITY DEVELOPMENT FENCES Applying for a Building Permit for a Fence Fences include: hedges, walls, woven wire, chain link, wood, and ornamental iron • Step 1: Check applicable fence regulations for the property. These can be found in Section 26 -603 of the Municipal Code. You may also contact a planner in the Community Development Department at 303- 235 -2846 to discuss the regulations. The illustration on the back of this handout also provides an overview of the regulations. • Step 2: Check if the property is located within the 100 year floodplain. Properties within the 100 year floodplain must obtain a floodplain special exception permit for a fence before the building permit may be approved. • Step 3. Submit building permit application. Supporting information required with the application includes a site plan showing the location of the fence relative to streets, existing structures and property lines as well as a description of the fence — including the height, materials, and length of the fence. A survey is not required for fences, but the permit does specify that you are responsible for locating your own property lines. • Step 4: Review and referral. The Community Development Department reviews and approves, approves with conditions, or specifies required corrections for the applicant. Fence Permit Process Building Permit and Sample Site Plan Step 1: Check fence regulations <hyd YA¢atflMpeBUlpbgIXMSbn mow. M omca:az- nszM •ru aarzismn application and supporting _ ,�,emwa: xs:xseu ewanovmnn MWUUm Step 2: Check floodplain status of property .. P� .. k.� . Not in floodplain L soa._ A so r,u,er { Step 3: Submit building permit ii I application and supporting documentation L y 4 I p y Ste Co mmunity P Development Review K: A - fi • D • �? K ;.� � i i v= to hhhlb,,�� ` zfYkG Community Development Department �11p 303- 235 -2846 (v) 303. 235.2857 (f) www.d.wheatridge.co.us t CD r? V ° u o 4! c � N N N t W , = Y 0 m O t Y •� C N - O Y m C m OO_ v v O c 3 O w O O m = O i O Y O > O T O CL C Q N Y u U E Y v CL 3 n m EON E :: g e� '1 lY , 3 "L ggg M a fig; y �^ f e, t h: !eq z x: G R6t • � N 7 r F 'px k W � h N ' v > ' Q s 1 d � ;C x � S 1 Q} 4 1 Co f � _ J Y v O 1 Y ` n U w' O c O G Y 6 CD s m / � .., � ., ii, l �i � � � � �- � � �.,� r . CITY OF WHEAT RIDGE f / Building Inspection Division l (303) 234 -5933 Inspection line Z/ (303) 235 -2855 Office • (303) 237 -8929 Fax 3 01 S 71 INSPECTION NOTICE /o Inspection Type: /l 9fmq - Job Address: 'F2 t<"d2C_ �07_ P ermit Number: // Zj 17,6 PC�i Y'GIt�sc. -� /�2lC�l2,. �CJrf"�•L� � L1 No No one available for Re- inspection required: Yes f� When corrections have been me Date: /o d Inspector: ne AM /PM , r re- inspection at 303234 -5933 VS NOTICE ♦ i CITY OF WHEAT RIDGE f 303) Building Inspection Division (303) 234 -5933 Inspection line 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: /V,4 -;n£ Job Address: .3�c0 11.6 2,55' 5 i Permit Number: 4AR,2&.'s I. ❑ No one available for inspection: Time ;2 AM Re- Inspection required: Yes When corrections have been made, call for re inspection at 303 - 234 - 5933 Date: 4 is i0 Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: /9e*45 Job Address: _3o � vA�MQf 5r Permit Number: 7 2 5_voV ar rra0 !a /�r>g 5 3 /. 5,C • ;� glzzc1! G.�P iti s3 /oc/� use / POWAv Sr 1142 1 ❑ No one available for inspection: Time / f'?.S' A IPM )_ Re- Inspection required: es 'No - "When corrections have been made, caU for re- inspection at 303 -234 -5933 Date: 8 ✓D Inspector DO NOT REMOVE THIS NOTICE us NhhS Fee 927.95 =_viewFee - .603.17 Valuation .00 K 1,.064.64 �,L * *? 2,595.76 Dns: comply w/ 2003 IRC:& 2005 :NEC. to field inspections. :'s letter of approval needed at time of final inspection for any ions to load bearing ;.walls. . zance..of a building permit should not be construed to be approval of a license. °tectors are required to be installed in every sleeping room, in .•hallways ' City of Wheat Ridge Residential Remodel PERMIT - 101267 PERMIT NO: 101267:: �. ISSUED: 05/17/2010 ` JOB ADDRESS:. 3200 'MOORE ST EXPIRES: 11/13/20.10 ° DESCRIPTION:. Kitchen cabinet & minor interior wall modification. �s ** CONTACTS * ** " owner 303/707 -0770 PWE: Residential LLC '.. r gc 303/707-0770 Brian White 10-0133 Rinack Walters Enterprises.' sub 303/898-9658 Wayne Kimmel 10 -0186 Ruby Electric, Inca. sub : 303/364-7536 Edward L. Jones 01-9972 Lee?Huddleston Plumbing, Inc. c us NhhS Fee 927.95 =_viewFee - .603.17 Valuation .00 K 1,.064.64 �,L * *? 2,595.76 Dns: comply w/ 2003 IRC:& 2005 :NEC. to field inspections. :'s letter of approval needed at time of final inspection for any ions to load bearing ;.walls. . zance..of a building permit should not be construed to be approval of a license. °tectors are required to be installed in every sleeping room, in .•hallways City of Wheat Ridge n,^ Residential Remodel PERMIT - 101267 PERMIT NO: >. 101267 ''ISSUED: 05/17/2010 JOB ADDRESS:.. 3200 MOORE ST EXPIRES: DESCRIPTION: Kitchen cabinet & minor interior wall modification. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: C Job Address: �— f 17 k& Si Permit Number: ro ��ITZtP�d���crr�D�K LxJ�. ,l�to�t�tc= �`tr�e� U i i - j `f i ❑ No one available for inspection: Time AM /PM j Re- Inspection required: Yes j N o * When correc tions ave been mader re -i spection at 303 -234 -5933 Date: U Inspecto DO NOT REMO IS NOTICE ' I City of WheatR,i COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application property A#slress_ 3200 Moore Street, Wheat Ridge, CO Property Owner (please print): PWE Residential LLC Phone: 303.707.0770 Mailing Address: (if different than property address) Address: 7323 S Alton Way, Unit A City, state, zip: Centennial, CO 80112 0 g�iractd: Pirnack Walters Commercial Contractors Contractors City License #: Electrical: City License # Phone: Date: Plan # � 0-1) 1 Permit # /0d c2 4.7 Plumbing: TBD City License # kitchen cabinet replacement / minor interior wall modifications BTU's Gallons Mechanical: TBD City License # Contract Value: 20 C s �' Review Fee (due at time of submittal): Ft. $ �/ �1 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: SIGNATURE: DATE: Bldg Valuatior#jF9 b® City of Wheat Ridge Building Permit Submittal List The following items are required for the single- or two family building permit submittal for the property located at 3200 Moore Street . If any of the required items are not included in the submittal, the submittal will be considered incomplete and returned immediately without review. This sheet must be submitted with the building permit application. Please initial beside each required item, signifying that it has been included. Review Required by: X Building 0 Planning 0 Public Works SUBMITTAL DOCUMENTS: Plans: 0 Three (3) full -sized (24"x 36 ") plans (Contents of plans detailed in the Single- and two- family handout) — yellow heading N/a Three (3) stamped sets of foundation plans. N/. O Three (3) copies of a grading and erosion control plan. MAI One (1) copy of a soils report. DOCUMENTATION: 0 One (1) completed building permit application. 0 One (1) property deed. Mg One (1) certified survey or Improvement Location Certificate. N/,M Proof of utility availability (form provided by city). 0 One (1) building permit submittal list. MAI One Grade /Fill permit. The following items are required for the commercial or nlUlti- family building permit submittal for the property located at . If any of the required items are not included in the submittal, the submittal will be considered incomplete and returned immediately without review. If you had a pre - application meeting with Staff, you must submit the checklist you received. Otherwise, this sheet must be submitted with the building permit application. Please initial beside each required item, signifying that it has been included. Review Required by: 0 Building 0 Planning 0 Public Works SUBMITTAL DOCUMENTS: Plans: 0 Four (4) full -sized (24"x 36 ") plans (Contents of plans detailed in the Commercial & Multi - family handout) — pink heading 0 Two (2) copies of a final drainage report and plan OR Two (2) copies of a drainage letter and plan 0 Two (2) copies of a grading and erosion control plan 0 Two (2) copies of a traffic impact study OR Two (2) copies of a trip generation study DOCUMENTATION: 0 One (1) completed building permit application. 0 One (1) property deed. 0 One (1) certified survey or Improvement Location Certificate. 0 Proof of utility availability (form provided by city). 0 One (1) building permit submittal list. 0 One Grade /Fill permit. Work shall comply with the following codes: 2003 IRC, 2003 IECC & 2005 NEC. Glass less than 60" above tub floor is required to be safety glazed. (E) Window Living EE R II o II om < J 0 14' -5" e ¢ a 9 (E) Window 6' -0" Cased Opening II Dining Room II I I II I I II I 1 3' -2" Cased 12'- 1" Opening 3 1 4 Cased Opening 0 V-0.1 I in L w II a 1U Great Room � ing m' II I 0 i� 1, -0„ o Dash line indicates Optional B -Vent - elements to be / / �' demolished, Typ. Gas Fireplace - -_—I r__ I� \ Coats \ \ \\ II \\ De4k Entry rn North Living /Kitchen i Gas fireplaces must comply With IFGC and manufacturer's installation specifications. Water hammer arrestors are required at quick - closing valves R2903.5 F --1 I I L - - - -_ 3' -2" Cased 36" Wide Opening Ref. — \ \ I J \ 2 A -3 1 \ I Kitchen j L J • 0" II I I I I L_ J 3' -4" 0 L 16 0 v w o Outlet type, location and spacinc shall comply with 2003 IRC and 2005 NEC. Breakfast Existing Skylights to remain, typ. of 4 3 O C W JB = (E) Door / Window Legend Existing to Remain E _ ] To be Demolished EM New Construction 15000 W. 6th Avenue Suite 330 Golden, CO 80401 303.984.9765p 303.984.9947f J M 0 00 Q i d m W d c W O o I N M Nlamlen. ILx+/mM PC aM M .1 remain ft P'Ca`l INS Mall Mt PACXITECNHE all ml M ogle; NmgaO. w N¢tlnsel N a,ry m �� In .1 PRCHnECNREPCyul nol� respvslde Irc arty tlb2tidu n rewloa: reaaa sr �w+a rarer uan PC em[loyiaedSX0 MCH"ECNRE PC. ®SHCI APCMEMREPC PROJ. NO: 10 -102 DRAWN BV: NNW ISSUE SCHEDULE No Desedption Date 1 Progress 05.06.10 REVISION SCHEDULE No Description Date Partial Floor Plan A -1 ca ' 'O, (DD m � W a0 c y m t> to v o W e ¢ a 9 (E) Window 6' -0" Cased Opening II Dining Room II I I II I I II I 1 3' -2" Cased 12'- 1" Opening 3 1 4 Cased Opening 0 V-0.1 I in L w II a 1U Great Room � ing m' II I 0 i� 1, -0„ o Dash line indicates Optional B -Vent - elements to be / / �' demolished, Typ. Gas Fireplace - -_—I r__ I� \ Coats \ \ \\ II \\ De4k Entry rn North Living /Kitchen i Gas fireplaces must comply With IFGC and manufacturer's installation specifications. Water hammer arrestors are required at quick - closing valves R2903.5 F --1 I I L - - - -_ 3' -2" Cased 36" Wide Opening Ref. — \ \ I J \ 2 A -3 1 \ I Kitchen j L J • 0" II I I I I L_ J 3' -4" 0 L 16 0 v w o Outlet type, location and spacinc shall comply with 2003 IRC and 2005 NEC. Breakfast Existing Skylights to remain, typ. of 4 3 O C W JB = (E) Door / Window Legend Existing to Remain E _ ] To be Demolished EM New Construction 15000 W. 6th Avenue Suite 330 Golden, CO 80401 303.984.9765p 303.984.9947f J M 0 00 Q i d m W d c W O o I N M Nlamlen. ILx+/mM PC aM M .1 remain ft P'Ca`l INS Mall Mt PACXITECNHE all ml M ogle; NmgaO. w N¢tlnsel N a,ry m �� In .1 PRCHnECNREPCyul nol� respvslde Irc arty tlb2tidu n rewloa: reaaa sr �w+a rarer uan PC em[loyiaedSX0 MCH"ECNRE PC. ®SHCI APCMEMREPC PROJ. NO: 10 -102 DRAWN BV: NNW ISSUE SCHEDULE No Desedption Date 1 Progress 05.06.10 REVISION SCHEDULE No Description Date Partial Floor Plan A -1 F 9 t 3 E I Outlets in bedrooms shall be arc - fault protected. Outlet type, location and spacing shall comply with 2003 IRC and 2005 NEC, o 0 w Direct connect smoke alarms are required. Cai(o r c{/�- h�c.�or5 �BP/urrL� 0 W APPROVED ` Subject to Field inspections Wheat Ridge Building Dept. Date: 5 Signed., Plan checker Pony Wall w/ Tempered Glazing above Master Suite 1/4" = 1' -0" G.C. to Field Verify all Dimensions Shutoff valves required on lavatories Walls in shower shall have non- and water closets. absorbent finish to 6' above floor. Minimum 30" clear area for ti required with minimum 15" f center to sidewall on each sidi In accordance with 2003 If Section R308, safety glazil required where indicated o plans / sc� SeaTrort,'�30E Tod d'o�urrr,� L.oea'�roa5 f oo Wheat Ridge Buijding Department proved St7iv BUIL . ING OFFICIAL ATE Validity of perms The issuance of a permit or approval of plans, specifications and computations shall not be a permit for, or an approval of, any violation to NW of the provisions of the building code or of any City ordinances. presuming to give authority to violate or cancel the provisions of the Building codes or other ordinances of the City shall not be valid. Minimum 50 CFM exhaust fan vented to exterior shall be provided in toilet rooms and bathrooms. City of Wheat Ridge .r- Res. Miscellaneous PERMIT - 101103 PERMIT NO: 101103 : (ISSUED 04/30/2010 JOB ADDRESS: 3200 MOORE ST : ;EXPIRES. 010 DESCRIPTION:'. Temporary Placement Permit dumpster. EXPIRES 5/15./2011-0 - c5 CONTACTS owner 303/707-0770 PWE Residential LLC gc 303/707-0770 Brian White 10-0133 Rinack Walters Enterprises PARCEL INFO " ZONE CODE: UA , USE: UA SUBDIVISION::' 0647 BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: .00 FEES Permit Fee .35.00 ' TOTAL 35.00 )ns: must be located a:minimum :of 6' inside front p ble this r( the ~u~ City of Wheatldge Temporary Placement Permit COMMUNITY DEVELOPMENT for Construction Dumpsters and Storage Containers Community Development Department City of Wheat Ridge 7500 W. 29th Avenue Wheat Ridge, CO 80033 (303) 235-2855 Date: _ April 29, 2010 Phone: (303) 707-0770 Property Owner: PWE Residential, LLC Address of Dumpster/Container: 3200 Moore Street Wheat Ridge, CO 80033 Size of orooosed dumpster/container: 30 Cu. Yds. Dumpster/Container Company: Waste Connections of Colorado Dumpster/Container Company Address: 5500 Franklin Street Denver, Co Dumpster/Container Company Phone Number: 303-288-2400 Will dumpster/container be located on private property? Yes 0 No ❑ Will dumpster/container be located on street? Yes ❑ No - (if yes, a separate right-of-way permit is required.) * THIS PERMIT EXPIRES FIFTEEN (15) DAYS FROM DATE OF APPROVAL. APPROVAL DATE: Permits are approved subject to the following conditions: 1.. Temporary dumpsters/containers may be allowed in all zone districts and must be located on private property. 2. If impractical to locate on private. property, a right-of-way permit may be obtained from the Public Works Department pursuant to Article III of Chapter 21 of the Wheat Ridge Code of Laws. Contact 303-235-2861. 3. Temporary dumpsters/containers shall not. be located so as to create sight, traffic, or safety obstructions. 4. Dumpsters/containers shall not block sidewalks or impede pedestrian traffic. 5. The area surrounding the dumpster/container shall be kept clean and free of debris. 6. Permittee is required to keep this permit displayed so as to be visible from the street. 7. Permittee assumes all liability and holds the City harmless against all claims, damages, suites, penalties, fines and liability for injury or death to persons or loss or damage to. property related to the placement of a dumpster/container in the City right-of-way. 8. The repair of any damage to pavement, curb, gutter, landscaping resulting from the placement, use or removal of the dumpster/container shall be the responsibility of the applicant and shall be performed to the satisfaction of the City. Fee: $35.00 Signature of Apl Approved By: Planning Division Building Division Public Works