HomeMy WebLinkAbout4695-4699 Garrison StreetCity of Wheat Ridge
Resid. Windows/Doors PERMIT - 201802308
PERMIT NO: 201802308 ISSUED:
08/20/2018
JOB ADDRESS: 4695 Garrison St EXPIRES:
08/20/2019
JOB DESCRIPTION: Install 2 code compliant egress windows.
*** CONTACTS ***
OWNER (720)320-7907 WARREN PAULA C
SUB (720)626-4221 Stephen Sennett 150231 Denver Egress Window
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE:
UA / Unassigned
SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#:
0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,000.00
FEES
Total Valuation 0.00
Use Tax 105.00
Permit Fee 125.05
** TOTAL ** 230.05
*** COMMENTS ***
*** CONDITIONS ***
windows shall comply with all applicable codes, have a .32 or better
U -factor and shall be
safety glazing if within a tub enclosure, less than 18 inches above
the floor or within 24
inches of a vertical edge of a door.
1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be perf"ormed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and maybe subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change. of the natural flow of water without prior and specific approval.
5_ The permit holder shall notify the Building and Inspection Services Div i4n in accordance with established policy of all required
inspections and shall not proceed or conceal work without written a oval`of such work from the Building and Inspection Services
Division.
6. T uance or gra g of a permit shall not be construed to b a permit f r, or an approval of, an violation of any provision of any
a abl 'ode or ordinance or regulation of this jurisdic 'o v 1 of work is subject to field inspection.
Signature of Chief Building Official Gam'
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
FOR OFFICE USE ONLY
City of RECEIVED Date:
W heat j�idge AUG 2 0 2018 JP. fP,
COMMUNiTy DEVELOPMENT Plan/Permit #
Building & Inspection Services Division�3 0
7500 W. 291h Ave., Wheat Ridge, CO 80033 Plan Review Fee:
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: permits ci.wheatridge.co.us
Building Permit Application
*** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ***
Property Address: ql(rcfs &f 15 yf) S11
Property Owner (please print): r, 4 vV �,,, few io Phone:
Property Owner Email:
Mailing Address: (if different than property address)
Address:
Citv. State
Architect/Engineer E-mail: �a^�yn��>w.��+s(Catd.� Phone: �' 4 �Iz Z
Contractor: L Jv ww ,yj fK-C LA A I
Contractors City License #: ISO 2-31 Phone: �P
Contractor E-mail Address: ivlU ti
f&4C4. (CO(LIJ
For Plan Review Questions & Comments (please print):
CONTACT NAME (please print): �4Phone: Z
CONTACT EMAIL(p/ease print): f
Sub Contractors:
Electrical: Plumbing: Mechanical:
W.R. City License # W.R. City License # W.R. City License #
Other City Licensed Sub: Other City Licensed Sub:
City License #
City License #
Complete all information on BOTH sides of this form
❑ COMMERCIAL K.$ESIDENTIAL
Description of work: (Check all that apply)
❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE
❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING
❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING
❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT
❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT
❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ OTHER (Describe)
(For ALL projects, please provide a detailed description of work to be performed, including current use of areas,
proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and
amount of materials to be used, etc.)
Sq. Ft./LF
Amps
Btu's
Squares
Gallons
Other
Project Value: (Contract value or the cost of all materials and labor included in the entire project)
$ � o L,a
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the
truthfulness of the information provided on the application.
CIRCLE ONE: (OWNER) RACT or (AUTHORIZED REPRESENTATIVE) o OWN (CONTRACTOR)
Signature (first and last name): t1{1v1Q 7�1� DATE:F—/e,
DEPARTMENT USE ONLY
ZONING COMMMENTS: OCCUPANCY CLASSIFICATION:
Reviewer:
BUILDING DEPARTMENT COMMENTS:
Reviewer:
Building Division Valuation: $ - -J y _-
Qty: (1) 30" x 48"
Location: Basement
Type: Tilt & turn
U Value: .19
At existing window
Existing lintel or
Window above NO
Floor joist bearing
Brick veneer
(720) 626-4221
a ".. WHERE APPLICABLE, BRICK VENEER IS SUPPORTED BY
EXISTING LINTEL. NO ADDITIONAL SUPPORT REQUIRED.
IF PRESENT, EXISTING STEEL LINTEL AT
BRICK VENEER TO REMAIN.EXISTING 2X FLOOR
/-JOISTS AND DECKING
HSS 6" x 2" x 1/8" MIN.
CUT SLOT FOR 3" BEARING,
MIN. TYPICAL BOTH ENDS -
MAKE A HORIZONTAL SAW CUT +/- 6"
BELOW BOTTOM OF EXISTING LINTEL INTO
EXISTING CONCRETE FOUNDATION WALL.
CUT A HORIZONTAL SLOT FOR TUBE STEEL
PLACEMENT = R.O. +9" WIDE. BELOW SLOT,
CUT HORIZONTAL AND VERTICAL ROUGH
OPENINGS +/- 3" FOR TRIMMING ALL SIDES
----- -- -- --�
(o
TOP OF 8" thk.
FOUNDATION
EXISTING WINDOW
R.O. +/- 3" .
co
OF NEW WINDOW. THE NEW WINDOW
• VERIFY DIMENSIONS
O
LOCATION MAY BE ALIGNED WITH BOTH
WITH WINDOW
`r
SIDES OF THE EXISTING WINDOW.
MANUFACTURER,
AND ADJUST S
SAWCUT
VERTICAL 2X
NOTE: WINDOW WELL SHALL BE 9 SQ. FT.
DIMENSIONS IF
TRIMMER
MIN. AREA WITH 36" MIN. CLEARANCE
REQUIRED.
FROM FOUNDATION WALL TO INSIDE OF
WELL. A PERMANENT LADDER IS
J
J_
REQUIRED IN THE WINDOW WELL IF
PLACE HORIZONTAL 2X U)
BOTTOM OF WELL IS 44" OR MORE BELOWx
NAILER SILL SNUGLY
0
GRADE.
BETWEEN VERTICAL
Q
�
NAILERS.
-00 Ln
Z
ih E_
H
ic
TOP OF FLOOR SLAB
Q
Front Wall
YES
header YES
YES
2'-6" X 4'-0" EGRESS WINDOW OPENING - INTERIOR ELEV.
V V SCALE: NONE
I Mark Benjamin P.E. have observed the
proposed installation and determined that
this detail meets existing conditions.
Building Code: 2012 IRC/IBC
Roof Snow: 30 psf
Ground Snow: 30 psf
Nominal Wind Speed: 105mph; 3 sec. gust. Exp. C
Seismic Design: Category B
08/10/22, 119,, PE`'� �
DRAWINGS PRODUCED BY: JOB ADDRESS: ENGINEER'S
PHI D & E. INC. dba : 4 695 GARRISON STREET, JOB #
CROWN JADE DESIGN AND WHEAT RIDGE SNTW1289-18550
ENGINEERING, LLC. DATE: 08/10/2018
P.O. BOX 17, SCALE: NONE
Fort Collins, COLORADO 80522
DRAWN BY: JK SHEET #
(970)-472-2394, (303)-358-2452 CHECKED BY: MB 1 OF 1
www.crown]ade.com SENNETT CLIENT 4: WARREN
(720) 626-4221
WHERE APPLICABLE, BRICK VENEER IS SUPPORTED BY
EXISTING LINTEL. NO ADDITIONAL SUPPORT REQUIRED.
IF PRESENT, EXISTING STEEL LINTEL AT
} ` BRICK VENEER TO REMAIN. / EXISTING 2X FLOOR
JOISTS AND DECKING
HSS 6" x 2" x 1/8" MIN.
CUT SLOT FOR 3" BEARING,
MIN. TYPICAL BOTH ENDS
MAKE A HORIZONTAL SAW CUT +/- 6"
BELOW BOTTOM OF EXISTING LINTEL INTO
EXISTING CONCRETE FOUNDATION WALL.
CUT A HORIZONTAL SLOT FOR TUBE STEEL
PLACEMENT = R.O. +9" WIDE. BELOW SLOT,
CUT HORIZONTAL AND VERTICAL ROUGH
OPENINGS +/- 3" FOR TRIMMING ALL SIDES
OF NEW WINDOW. THE NEW WINDOW
LOCATION MAY BE ALIGNED WITH BOTH
SIDES OF THE EXISTING WINDOW.
NOTE: WINDOW WELL SHALL BE 9 SQ. FT.
MIN. AREA WITH 36" MIN. CLEARANCE
FROM FOUNDATION WALL TO INSIDE OF
WELL. A PERMANENT LADDER IS
REQUIRED IN THE WINDOW WELL IF
BOTTOM OF WELL IS 44" OR MORE BELOW
GRADE.
Qty: (1) 30" x 48"
Location: Basement Front Wall
Type: Tilt & turn
U Value: .19
At existing window YES
Existing lintel or header YES
Window above NO
Floor joist bearing YES
Brick veneer
--I
0
EXISTING WINDOW
R.O. +/- 3„ . —
VERIFY DIMENSIONS
WITH WINDOW
MANUFACTURER,
AND ADJUST SAWCUT
DIMENSIONS IF
REQUIRED.
"TOP OF 8" thk
FOUNDATION
ih
O +i
r`
VERTICAL 2X
TRIMMER
J
PLACE HORIZONTAL 2X
NAILER SILL SNUGLY
BETWEEN VERTICAL
NAILERS.
TOP OF FLOOR SLAB
2'-6" X 4'-0" EGRESS WINDOW OPENING - INTERIOR ELEV.
V V SCALE: NONE
I Mark Benjamin P.E. have observed the
proposed installation and determined that
this detail meets existing conditions.
Building Code: 2012 IRC/IBC
Roof Snow: 30 psf
Ground Snow: 30 psf
Nominal Wind Speed: 105mph; 3 sec. gust. Exp. C
Seismic Design: Category B
08/10/2v 0 t�'S
.B-E'J�,�
L7 � 4�4` t
DRAWINGS PRODUCED BY: JOB ADDRESS: ENGINEER'S
PHI D & E, INC. dba : 4 695 GARRISON STREET, JOB #
CROWN JADE DESIGN AND WHEAT RIDGE SNTW1289-18550
ENGINEERING, LLC. DATE: 08/10/2018 1�
P.O. Box 17, SCALE: NONE SHEET #
Fort Collins, COLORADO 80522 DRAWN BY: JK
(970)-472-2394, (303)-358-2452 CHECKED BY: MB 1 OF 1
www.crownjade.com SENNETT CLIENT #: WARREN
City of Wheat Ridge
Resid. Windows/Doors PERMIT - 201801183
PERMIT NO: 201801183 ISSUED: 04/26/2018
,JOB ADDRESS: 4699 Garrison ST EXPIRES: 04/26/2019
JOB DESCRIPTION: Install 1 code compliant egress window; u -value = .19
*** CONTACTS ***
OWNER (720)320-7907 WARREN CHRISTINE
SUB (720)626-4221 Stephen Sennett 150231 Denver Egress Window
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 3,000.00
FEES
Total Valuation 0.00
Use Tax 63.00
Permit Fee 93.35
** TOTAL ** 156.35
*** COMMENTS ***
*** CONDITIONS ***
Windows shall comply with all applicable codes, have a .32 or better U -factor and shall be
safety glazing if within a tub enclosure, less than 18 inches above the floor or within 24
inches of a vertical edge of a door.
I, by in signature, do hexeby'attest-.that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building bodes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal own r -'of the pro and am authoriz his permit and perform the work described and approved in conjunction with
this_permit. I f her attest at I m 1 ` a orized to include all entities named within this document as parties to the work to be
performed a that all rk to or ed is disclosed in u docume t and/ its' accompanying app ved plans and specifications.
` � Z--7 C
Signature of40WNER or EONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the pennit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180. days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal w.Qrk without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit of be lonstrued to be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordinance regul ion o th' ' isdiction. Approval of work is subject to field inspection.
Signature of Chief iciF�n x Date
REQUESTS MUST BE'MADE BY 11:59PM BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of
WIY heatPF �
COMMUN(DEVELOPMENT
Building & Inspection Services Division
7500 W. 29' Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: Permits6d�cimheatridge.co.us
FOR OFFICE USE ONLY
Date:
Plan/Permit # A I I N �(
Plan Review Fee:
Building Permit Application
** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ***
Property Address: (09 C/'01 M V -
Owner
Property Owner Email:
Mailing Address: (if different than property address)
Address: L
VV
City, State, Zip: Q �-� / �� �J6
Architect/Engineer:
Architect/Engineer E-mail:
Contractor: �pl-s V'e,
Contractors City License #:
Contractor E-mail Address: 1
Phone:
Phone:
Phone:-,/
For Plan Review Questions & Comments (please p
rint):
CONTACT NAME (please print): ST Y �1 Phone:
CONTACT EMAIL(please print): j V1 e Avy r rc 40VT m
Sub Contractors:
Electrical:
W.R. City License #
Other City Licensed Sub:
City License #
City License #
Plumbing:
W.R. City License #
Other City Licensed Sub:
Mechanical:
W.R. City License #
Complete all information on BOTH sides of this form
2-21
❑ COMMERCIAL RESIDENTIAL
Description of work: (Check all that apply)
❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE
❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING
❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING
❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT
❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT
❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ OTHER (Describe)
(For ALL projects, please provide a detailed description of work to be performed, including current use of areas,
proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and
amount of materials to be used, etc.)
Sq. Ft./LF
Amps
Cot- c-ol�
1
Btu's
Squares
Gallons
Other
Project Value: (Contract value or the cost of all materials and labor included in the entire project)
$ i ((1U
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the
truthfulness of the information provided on the application.
CIRCLE ONE: (OWNER) T or ( ORIZED REPRESENTTA E) of OWN (CONTRACTOR)
Signature (first and last name): DATE:
ZONING COMMMENTS:
Reviewer
BUILDING DEPARTMENT COMMENTS:
Reviewer:
DEPARTMENT USE ONLY
OCCUPANCY CLASSIFICATION -
Building Division Valuation: $
WHERE APPLICABLE, BRICK VENEER IS SUPPORTED BY
EXISTING LINTEL. NO ADDITIONAL SUPPORT REQUIRED.
EXISTING STEEL LINTEL AT
BRICK VENEER TO REMAIN. /� EXISTING 2X FLOOR
,/ JOISTS AND DECKING
HSS 6" x 2" x 1/8" MIN
CUT SLOT FOR 3" BEARING,
MIN. TYPICAL BOTH ENDS
MAKE A HORIZONTAL SAW CUT +/- 4"
BELOW BOTTOM OF EXISTING LINTEL INTO
EXISTING CONCRETE FOUNDATION WALL.
CUT A HORIZONTAL SLOT FOR TUBE STEEL
PLACEMENT = R.O. +9" WIDE. BELOW SLOT,
CUT HORIZONTAL AND VERTICAL ROUGH
OPENINGS +/- 3" FOR TRIMMING ALL SIDES
OF NEW WINDOW. THE NEW WINDOW
LOCATION MAY BE ALIGNED WITH BOTH
SIDES OF THE EXISTING WINDOW.
NOTE: WINDOW WELL SHALL BE 9 SQ. FT.
MIN. AREA WITH 36" MIN. CLEARANCE
FROM FOUNDATION WALL TO INSIDE OF
WELL. A PERMANENT LADDER IS
REQUIRED IN THE WINDOW WELL IF
BOTTOM OF WELL IS 44" OR MORE BELOW
GRADE.
v
EXISTING WINDOW
R.O. +/- 3" .
VERIFY DIMENSIONS
WITH WINDOW
MANUFACTURER,
AND ADJUST SAWCUT
DIMENSIONS IF
REQUIRED.
STOP OF
FOUNDATION
ih
VERTICAL 2X +1
TRIMMER
r`
PLACE HORIZONTAL 2X
NAILER SILL SNUGLY
BETWEEN VERTICAL
NAILERS.
TOP OF FLOOR SLAB
E� p / 2'-6" X 4'-0" EGRESS WINDOW OPENING - INTERIOR ELEV.
V V SCALE: NONE
Qty: (1) 30" x 48"
Location: Basement Front wall
Type: Tilt & Turn
U Value: .19
At existing window YES
Existing lintel or header YES
Window above YES
Floor joist bearing YES
Brick siding
I Mark Benjamin P.E. have observed
the proposed installation and
determined that this detail meets
existing conditions.
Building Code: 2012 IRC/IBC
Roof Snow: 30 psf
Ground Snow: 30 psf
Nominal Wind Speed: 105mph; 3 sec. gust. Exp. C
Seismic Design: Category B
PHI D & E INC. dba:
CROWN JADE DESIGN
AND ENGINEERING
P.O. Box 17,
Fort Collins, COLORADO 80522
(970)-472-2394, (303)-358-2452
www.crownjade.com
04/17/2 �' ......"S
.
3 E -tv
JOB ADDRESS:
4699 GARRISON STREET,
WHEAT RIDGE
DATE: 04/17/2018
SCALE: NONE
DRAWN BY: JK
CHECKED BY: MB
SENNETT JOB #: WARREN
ENGINEER'S
JOB #
SNTW1160-18228
SHEET #
1 OF 1
WHERE APPLICABLE, BRICK VENEER IS SUPPORTED BY
EXISTING LINTEL. NO ADDITIONAL SUPPORT REQUIRED.
EXISTING STEEL LINTEL AT
BRICK VENEER TO REMAIN. EXISTING STS AND
FLOOR
,�—JOID DECKING
11 fir -----7rl----tIr--- V1 11
HSS 6" x 2" x 1/8" MIN. ---,,,'k
CUT SLOT FOR 3" BEARING,
MIN. TYPICAL BOTH ENDS
MAKE A HORIZONTAL SAW CUT +/- 4"
BELOW BOTTOM OF EXISTING LINTEL INTO
EXISTING CONCRETE FOUNDATION WALL.
CUT A HORIZONTAL SLOT FOR TUBE STEEL
PLACEMENT = R.O. +9" WIDE. BELOW SLOT,
CUT HORIZONTAL AND VERTICAL ROUGH
OPENINGS +/- 3" FOR TRIMMING ALL SIDES
OF NEW WINDOW. THE NEW WINDOW
LOCATION MAY BE ALIGNED WITH BOTH
SIDES OF THE EXISTING WINDOW.
NOTE: WINDOW WELL SHALL BE 9 SQ. FT.
MIN. AREA WITH 36" MIN. CLEARANCE
FROM FOUNDATION WALL TO INSIDE OF
WELL. A PERMANENT LADDER IS
REQUIRED IN THE WINDOW WELL IF
BOTTOM OF WELL IS 44" OR MORE BELOW
GRADE.
EXISTING WINDOW
R.O. +/- 3" *
* VERIFY DIMENSIONS
WITH WINDOW
MANUFACTURER,
AND ADJUST SAWCUT
DIMENSIONS IF
REQUIRED.
—TOP OF
FOUNDATION
O
X.
VERTICAL 2X +1
TRIMMER
PLACE HORIZONTAL 2X
NAILER SILL SNUGLY
BETWEEN VERTICAL
NAILERS.
TOP OF FLOOR SLAB
E� n/ 2'-6" X 4'-0" EGRESS WINDOW OPENING - INTERIOR ELEV.
V V SCALE: NONE
Qty: (1) 30" x 48"
Location: Basement Front wall
Type: Tilt & Turn
U Value: .19
At existing window YES
Existing lintel or header YES
Window above YES
Floor joist bearing YES
Brick siding
01
I Mark Benjamin P.E. have observed
the proposed installation and
determined that this detail meets
existing conditions.
Building Code: 2012 IRC/IBC
Roof Snow: 30 psf
Ground Snow: 30 psf
Nominal Wind Speed: 105mph; 3 sec. gust. Exp. C
Seismic Design: Category B
PHI D & E INC. dba:
CROWN JADE DESIGN
AND ENGINEERING
P.O. Box 17,
Fort Collins, COLORADO 80522
(970)-472-2394, (303)-358-2452
www.crownjade.com
04/17/2,i�`,0
Vin• ..:�••� �'
JOB ADDRESS:
4699 GARRISON STREET,
WHEAT RIDGE
DATE: 04/17/2018
SCALE: NONE
DRAWN BY: JK
CHECKED BY: MB
SENNETT JOB #: WARREN
ENGINEER'S
JOB #
SNTW1160-18228
SHEET #
1 OF 1
INSPECTION RECORD
Inspection online form: http://www.ci.wheatridge.co.us/inspection
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site
Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day
PERMIT: 1�O tr,7 ADDRESS: ��VI.5- ( OOly Zbm ")J:" JOB CODE: '
Foundation Inspections
Date
Inspector
Initials
Comments
102 Caissons / Piers
103 Footing / P.E. Letter
104 Foundation Setback Cert.
105 Stem Walls
106 Foundation wall Insulation
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground / Slab Inspections
Date
Inspector
Initials
Comments
201 Electrical / Cable/ Conduit
202 Sewer Underground Int.
203 Sewer Underground Ext.
204 Plumbing Underground Int.
205 Plumbing Underground Ext.
206 Water Underground
Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections
Rough Inspection
Date
Inspector
Initials
Comments
301 Rough Framing
302 Wall Sheathing
303 Roof Sheathing
304 Sheer Inspection
305 Insulation
306 Mid -Roof
307 Metal / Lath / Stucco
308 Rough Electrical Residential
309 Rough Electrical Commercial
310 Electrical Meter Residential
311 Electrical Meter Commercial
312 Temp. Const. Meter
313 Rough Plumbing Residential
314 Rough Plumbing Commercial
315 Shower Pan
SEE OVER FOR ADDITIONAL INSPECTIONS
PERMIT:a6I�05qW ADDRESS: 46q6 6ay?7 Y';1JOB CODE:.
Rough Inspection (continued)
Date
Inspector
Initials
Comments
316 Rough Mechanical Residential
317 Rough Mechanical Commercial
318 Boiler / Furnace
319 Hot water tank
320 Drywall screw and Nail
321 Moisture board / shower walls
322 Rough Grading
323 Miscellaneous
Final Inspections
Date
Inspector
Initials
Comments
402 Gas Meter Release
403 Final Electrical Residential
404 Final Electrical Commercial
405 Final Mechanical Residential
406 Final Mechanical Commercial
407 Final Plumbing Residential
408 Final Plumbing Commercial
409 Final Roof
410 Final Window/Door
411 Landscape/Park/Planning*
Inspections from these entities shall be requested
one week in advance.
*For landscaping and parking inspections please
call 303-235-2846
"For ROW and drainage inspections please call
303-235-2861
***For fire inspections please contact the Fire
Protection District for your project.
412 Row/Drainage/Public Works**
413 Flood plain Inspection**
414 Fire Insp. / Fire Protection***
415 Public Works Final**
416 Storm Water Mgmt.**
417 Zoning Final Inspection*
418 Building Final Inspection
Note: All items must be completed and approved by Planning, Public Works, Fire and Building
before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not
constitute authorization of occupancy.
For Low Voltage permits please be sure that rough inspections are completed by the Fire District and
Electrical low voltage by the Building Division.
A i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number: -10/"/- Q 37 6'Z—
❑ No one available for inspection: Time �'� AM/PM
Re -Inspection required: Yes t No'
When corrections have been made, call for re-tHspection at 303-234-5933
Date: f r Inspector: j/V r; ,
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
_1�9rBuilding Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:z��
Job Address:
Permit Number:
l
1-1No one available for inspection: Time% « AM/PM
Re -Inspection required: �esNo
When corrections have been made, call for re-insp� 'on at 303-234-5933
r " L /
Date:-�' f Inspector:
DO NOT REMOVE TI,I�S NOTICE
i CITY OF WHEAT RIDGE
_1�9rBuilding Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:z��
Job Address:
Permit Number:
l
1-1No one available for inspection: Time% « AM/PM
Re -Inspection required: �esNo
When corrections have been made, call for re-insp� 'on at 303-234-5933
r " L /
Date:-�' f Inspector:
DO NOT REMOVE TI,I�S NOTICE
A i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number: -10/"/- Q 37 6'Z—
❑ No one available for inspection: Time �'� AM/PM
Re -Inspection required: Yes t No'
When corrections have been made, call for re-tHspection at 303-234-5933
Date: f r Inspector: j/V r; ,
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: r 8 r -
Job Address: y (, ct ` C A f 0 0 77
Permit Number: Ci -3
r
❑ No one available for inspection: Time F -- AM/PM
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303 -234-
Date: -
03 -234 -Date: 3 4 f Inspector:
DO NOT REMOV THIS NOTICE
i City of Wheat Ridge
.-
��`� Residential Roofing PERMIT - 201703962
PERMIT NO:
201703962
ISSUED:
07/13/2017
JOB ADDRESS:
4695 Garrison ST
EXPIRES:
07/13/2018
JOB DESCRIPTION:
Residential Re -roof
to install
Owens Corning Duration
asphalt shingles - 30
sq
*** CONTACTS ***
OWNER (303)901-5416
WARREN LEONARD
SUB (720)271-3718
Josh Mudock/Billy
Sweeney
150095 1st Priority Roofing
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE:
UA / Unassigned
SUBDIVISION CODE:
2002 / KIPLING, I-70
& CLEARCREEK ARE BLOCK/LOT#:
0 /
*** FEE SUMMARY ***
ESTIMATED PROJECT VALUATION:
16,500.00
FEES—
Total Valuation
0.00
t
Use Tax
346.50
Permit Fee
315.25
** TOTAL **
661.75
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are
required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and
water shield is required. Eave and rake metal is required. A ladder extending 3 feet above
the roof eave and secured in place is required to be provided for all roof inspections.
Roof ventilation is required to comply with applicable codes and/or manufacturer
installation instructions, whichever is more stringent. In order to pass a final inspection
of elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer technical representative stating that "the application of the roof at (project
address) has been applied in accordance with the installation instruction for (roof
material brand name) roof covering" is required to be on site at the time of final
inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
City of Wheat Ridge
Residential Roofing PERMIT - 201703962
PERMIT NO: 201703962 ISSUED: 07/13/2017
JOB ADDRESS: 4695 Garrison ST EXPIRES: 07/13/2018
JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration asphalt shingles - 30
sq
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications;
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of th roperty and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further a s that I am legally authorized to include all entities named within this document as parties to the work to be
performed and i a work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signatur of O R or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
appli de or any ordinance or regulation of this jurisdiction. Approval of work is subject to f any
inspection.
_
56U0j-A-
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dane Lovett ?ol7o�q6L
From: no-reply@ci.wheatridge.co.us
Sent: Friday, June 30, 2017 11:09 AM
To: Permits CommDev
Subject: Online Form Submittal: Residential Roofing Permit Application
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in TZ -3
the order they are received and due to the volume of requests, time to process G
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Duplex
are on the property?
PROPERTY INFORMATION
Property Address 4695 & 4699 Garrison St
Property Owner Name Leonard Warren
Property Owner Phone 303-901-5416
Number
Property Owner Email Field not completed.
Address
Do you have a signed
Yes
contract to reroof this
property?
It will need to be
provided at the time of
permit pick-up.
CONTRACTOR INFORMATION
Contractor Name
1 st Priority Roofing
Contractor's License
150095
Number (for the City of
Wheat Ridge)
Contractor Phone
7202713718
Number
Contractor Email Address
info@1 stpriorityroofing.com
Retype Contractor Email
info@1 stpriorityroofing.com
Address
DESCRIPTION OF WORK
Are you re -decking the
No
roof?
Description of Roofing
oc duration
Material
Select Type of Material:
Asphalt
If "Other" is selected
Field not completed.
above, describe here:
How many squares of the
30
material selected above?
Does any portion of the
No /
property include a flat
roof?
If yes, how many squares
Field not completed.
on the flat roof?
TOTAL SQUARES of all
30 /
roofing material for this
`
proj ect
Provide additional detail
tear off to deck and replace with oc duration, 5:12 pitch, house
here on the description of
P]
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
Project Value (contract 16500
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant Josh Murdock
Email not displaying correctly? View it in your browser.
3
BBB . Q
A"g'®$l's
Reviews you can trust. 1 st Priority Roofing
NAME .�
W, �- /�f iii+
I., / All, �i i�'i �/i /. './� n („}L•1.) -f is �r'.� C ! 1 :(i/.%
ADDRESS CITY -7 ✓ ) / % STATE ZIP
HOME PHONE J CELL PHONE E-MAIL �T
By signing below, you give 1st Priority authorization to negotiate with your insurance company regarding any claims related matter. 1s` Priority agrees to
perform the work specified by below (roof and gutter related items only) for the final approved insurance replacement cost value (RCV), overhead & profit
and supplements only, with no additional cost to you except for your deductible, city code requirements unpaid by your insurance, and any upgrades or
additional work authorized by you and lit Priority management in writing. Deposits made shall be held in trust until roofing materials have been
delivered. 1�` Priority Roofing cannot rebate, waive or pay an insurance deductible in part or full.
Claim #• ('1ln.� 7 -7C; I )Lli - 1--ran—('n
1st
*This number is only an estimate, final price is confirmed after supplements and building ordinance is finali
agree by signing below, to all terms and conditions on both the front and the back of this contract.; �SiX
1 � t�a ,
SIGNATURE DATE PRINTED NAME
,// ' . / / A/% / c / it t%
DATE / PRINTED NAME
Corporate: 7208 S. Tucson Way, Ste 195 / Centennial, CO 80112. Info@1stPriorityRoofing.com
Denver (720) 271-3718 1 CO Springs (719) 646-0968 1 FT Collins (970) 817-6154 1 V1.2017
/L- 41 _ '
- 7
Shingle Brand / Type
� "i/ 1 14_4494 11/1 r al .. X 0.1
Asphalt Layers
Shake Layers
Shingle / Covering Color
X
Flat [Under 2:12]
Dbl Felt [2-4:12]
Sheathing
N. —, Main Dwelling Spot Repair ($75
eet) Steep [7-9:12]
Steep [10-12:12]
e'
Starter Course
Standard
Two Story p
Three Story
Drip Eave (2x4)
Color
iL X
Hand Load Y /
Poor Access
Y /(`N
Drip Rake (D -Style)
Color - ,
t XEave
LF 2--2-1Rake
LF
Felt
Synthetic
Valley LF 2
Ridge/Hip LF
Ice Shield
Penetrations Valley
I Eave (/
Step Flashing LF
Wall Flashing LF
.E;�'
Ridge & Hip Cap
Standard High Profile
Soffit Depth -
Open Soffit
Y /(g)
Ventilated Ridge
LF T
Satellite: Remove
etach &Reset
Turtle / Box Vents
Z1
Solar Panels: Remove / Detach & Reset
Pipe Boots /Split Boots
Gutters (By Roofer)
Furnace Cap
3in1 4"
Remove / Detach &Reset
Replace Cap/ N
Slit Boot
/ NA
Replace Collar
'� -0himne
—.,Y
nt--. Y
Build ACounter Flask--- YY_ %
Y / NStep lash: Y / N
tji9ja "A 1n
Gutters
Downspouts
-» it
LF LF
LF LF
5k I' Flashing Kit
LF LF Size(s)
Color: Cl Tinte
r D LF LF T urbed / Fixed / Flat �ome_._
Corners/Elbows
Gutter/Downspout Color
EA EA
Color , , e
EA
X
EA acPied BUitdin .�
04J.2 M2 ert`"rrial Type
- -- 3 s
Color
Special Instructions
7Do.✓vt „Pv✓ k
SbedWs
enal T s
YPe
Patio/Med-Bif:a
erial Type
s-
o
aco�w��tiynrt �a« �•�,�;
Replacement Cost Value
$
Estimated Supplements & O&P
$
Non -Insurance Additions
$
Approximate Date Of Service: -, -7
*Estimated Total
'$
1st
*This number is only an estimate, final price is confirmed after supplements and building ordinance is finali
agree by signing below, to all terms and conditions on both the front and the back of this contract.; �SiX
1 � t�a ,
SIGNATURE DATE PRINTED NAME
,// ' . / / A/% / c / it t%
DATE / PRINTED NAME
Corporate: 7208 S. Tucson Way, Ste 195 / Centennial, CO 80112. Info@1stPriorityRoofing.com
Denver (720) 271-3718 1 CO Springs (719) 646-0968 1 FT Collins (970) 817-6154 1 V1.2017
1. Sign ees of this contract warrant that they are fully authorized to enter into this transaction and accept full responsibility and liability for the terms and conditions oft his contract. The party
contracting for work may be called "client, owner, homeowner, or customer." 1" Priority Roofing may be called 'company or 1" Priority.'
2. All proposals (including'work outside the insurance scope') are subject to approval by 1st Priority Roofing, LLC executive management and shall be made in writing (sales representatives and
project managers are not 'executive management'). Any amendments to this contract shall be made in writing and require approval from 1" Priority executive management. Any statement
made after the conclusion of a valid written contract shall not be considered a valid part ofthis contract, nor shall it be considered binding or enforceable. All verbal and 'text message'
agreements are strictly prohibited. This constitutes the entire agreement between 1" Priority Roofing and client. Any representations or statement not included herein are immaterial and shall
not be relied upon by any party.
3. This contract is binding upon signature. Client may cancel this contract without penalty within 72 hours after entering this contract by writing a letter to 1" Priority Roofing, 7208 S Tucson Way,
Suite 195, Centennial CO, 80112, requesting a cancelation or hand delivering this letter to authorized personnel at this same address. An email sent to info@1stPrioritvRoofinp.com is also
sufficient, but must be accompanied by confirmation of receipt from 1" Priority Roofing; without 1" Priority Roofing's acknowledgement in writing via email response, the cancellation shall not
be considered valid. The postmark and or electronic date shall be used to determine timeliness. Deposits are refundable ifthe contract is cancelled within the allotted time frame except for
when services have already been performed, including but not limited to; permits being pulled, the purchase of materials, negotiations with customer's insurance company that results in
customer enrichment (supplements). If this contract is cancelled by the customer after the allotted time frame, customer agrees to pay 1st Priority Roofing, LLC twenty (20%) percent of the
contract price as liquidated damages, not as a penalty, but as fair and just compensation for all services to that point.
4. 1" Priority Roofing is insured by M.U.S.I.0 for general liability insurance. 1-480-306-8300. 6263 N Scottsdale Rd, Suite 300, Scottsdale, AZ 85250. Insurance providermay change change.
5. The "estimated costs of services" on the front of this contract is strictly an estimate and subject to change based upon unforeseen work that arises and/or additional supplements approved by
your insurance company. The final cost of services is the final approved replacement cost value (RCV) (including approved supplements, O&P, and your deductible) plus any additional work
authorized by you in writing, plus additional work completed because 1" Priority determined it was best construction practice at the time (see N16), and any work required or recommended by
the City or State per city code or recommended by manufacturer specifications. Customer is responsible to pay the above in full regardless of any amounts deducted by customer's insurance or
mortgage company for "non-recoverable depreciation," "no code upgrade," or similar or dissimilar policy language and issues.
6. 1" Priority reserves the right to perform the specified repairs / replacement in accordance with generally accepted roofing and construction guidelines (including any combination of IRC,
Manufacturer or City Code as determined by 1" Priority Management), and using similar (though not necessarily identical) materials unless otherwise agreed upon in writing. 1" Priority Roofing
shall be considered to have fulfilled its contractual obligations once repairs have been substantially completed within these guidelines. Should a dispute arise as to the definition of such
guidelines, 1" Priority Roofing management shall inspect the completed repairs and shall have sole authority to determine if the work meets such guidelines, thus fulfilling contractual
obligations. Customer agrees to release all funds agreed upon in this contract to 1" Priority Roofing once work is substantially completed and has been determined to meet such guidelines.
Pending or failed city or mortgage bank inspections shall not constitute a breach of contract, nor shall it be an allowable reason to withhold payment for work substantially complete.
7. 1st Priority Roofing, LLC's standard payment terms are as follows: 50% deposit upon acceptance of contract and balance upon substantial completion of work. The work shall be substantially
complete even though warranty or minor work may be unfinished, or permits still open. 1" Priority Roofing is expressly authorized to determine the date of substantial completion. Client shall
not withhold any funds or proceeds from 1" Priority Roofing for work that has been substantially completed while additional project items are in process. Endorse and/or make all checks
payable to 1st Priority Roofing, LLC.
8. Client is responsible for procuring any third party endorsement(s), such as lenders (Mortgage Company) approval or HOA approvals for projects in a timely manner.
9. Client acknowledges 1st Priority Roofing, LLC as General Contractor and as such will be entitled to 10% overhead and 10% profit. Client also acknowledges that any additional supplements
negotiated by 1" Priority Roofing, LLC shall be awarded to 1" Priority Roofing unless otherwise agreed upon by 1" Priority Roofing executive management in writing.
10. Past due accounts are defined when work has been substantially completed by 1st Priority Roofing, LLC and 30 days have passed. Any portion remaining unpaid will bear interest at the rate of
eighteen percent (18%) per annum commencing thirty (30) days after substantial completion. In addition, if 1st Priority Roofing, LLC requires an attorney for collection, client agrees to pay all
costs incurred in pursuit of collecting any unpaid portion of this contract, including reasonable legal/attorney fees and collection agency fees. Should default be made in payment of this
contract, 1st Priority Roofing, LLC reserves the right to place a mechanic's lien on the contract property. Lien costs shall be charged in addition to contract price.
11. 1st Priority Roofing, LLC shall not be in breach of contract or held liable for failure of performance due to labor controversies, strike, fire, hail, weather, inability to obtain material from usual
sources, failed or pending city inspections, manufacturer defects or voided manufacturer warranties, or any other circumstances beyond the control of 1st Priority Roofing, LLC whether of
similar or of dissimilar nature.
12. 1st Priority Roofing, LLC's standard workmanship warranty for roofing is five (5) years and one (1) year for all other work. Client must notify 1" Priority Roofing in writing if a warranty is to be
transferred to new owners. Transfers may be done one time by the original customer. Warranty shall be void if these steps are not taken. Warranties are only valid if customer has paid all
obligations in full per contract. All warranties are void if legal action or a collections agency were needed to collect the balance, or if the account is 90 days past due.
13. 1" Priority Roofing, LLC is not responsible for any leaks or water damage below the roofline as a result of ice damming, insufficient insulation, defective materials, poor architecture or design of
property/roof, excessive wind, rain, snow, ice or hail during the period of warranty. Leaks that are a result of repair work outside the original scope of this contract shall be paid at the sole
expense of client, even if the repair work required is a result of work (or demolition) done by 1" Priority Roofing in the normal process of remodeling.
14. Customer/Property Owner/Renter agrees to indemnify 1st Priority Roofing LLC against and hold 1st Priority Roofing LLC harmless for any and all claims, demands, liabilities, losses, expenses,
suits and actions (including attorney's fees) for or on account of any injury to any person, or any death at any time resulting from such injury, or any damage to any property, which may arise (or
which may be alleged to have risen) out of or in connection with the work covered by this contract even though such injury, death, or damage may be (or may be alleged to be) attributable in
part to negligence or other fault on the part of 1st Priority Roofing LLC or its officers, subcontractors, agents or employees. Customer/property owner/renter agree to hold harmless 1st Priority
Roofing, LLC, its agents and/or employees for damage to real, private or personal property, whether exterior or interior through negligence, accident or competence, including but not limited to;
slight scratching or denting of gutters, oil droplets in the driveway, nails perforating soffit or fascia, cracks in concrete, paint spills or droplets, scuffs or tar on siding, broken siding, broken
windows or glazing, damage to plants or shrubbery, sunken foundation or framing, broken or fallen crown molding or stucco, solar panels, evaporative coolers, existing skylights, personal
property such as pictures, cars, or interior damage such as cracked plaster, damaged sheetrock or drywall, nail pops, or falling dust and debris as a result of roof replacement, additional
contracted work, cleanup or through happenstance.
15. If material has to be reordered or restocked because of cancellation by customer, there will be a restocking fee equal to twenty percent (20%) of the contract price.
16. Replacement or repair of any deteriorated decking not covered by insurance, or expressly agreed to in writing beforehand, shall be charged at $225.00 per square. Fascia boards, furnace or
hvac work, swamp coolers, ventilators, chimneys, counter flashing, or any other work completed for client not stated in this contract are not included and will be charged above contract terms
on a time and material basis. Customer also agrees to pay 1" Priority Roofing for work required by City, recommended per manufacturer specifications, installed due to safety concerns, or
installed because 1" Priority considered it to be best construction practice at the time but may not be specifically disclosed in this agreement or paid for by customer's insurance policy.
17. 1" Priority Roofing, LLC is not a licensed engineer and recommends that customer consults a licensed engineer in cases where additional items not already pre-existing (such as roofing vents,
skylights, or specialty roof covers including but not limited to TPO, cement shingles, etc,) are installed, or in cases where the structure of the existing building may not be up to current city code
(including framing, truss structure, etc). Customer assumes all responsibility for these items and shall hold 1" Priority Roofing harmless in the event of any controversy arising thereof.
18. The Insurance Company Adjuster Summary (and all revisions) is a legal part of this contract. Customer agrees to allow 1" Priority Roofing to discuss all aspects of the claim with customer's
Insurance Company (including additional revisions and monetary values of the claim) and Mortgage Company. Customer agrees to secure a copy of all revisions of the Adjuster Summary related
to customer's claim on behalf of 1" Priority Roofing.
19. 1" Priority Roofing retains the right to require that any controversy or claim arising out of or related to this contract for alleged breach thereof be mediated before any further legal action may
be undertaken. Mediation costs shall be paid for at the sole expense of customer. If mediation is unsuccessful, 1" Priority Roofing may require that the controversy be resolved by binding
arbitration with a single arbitrator, chosen by 1" Priority Roofing. Arbitration fees shall be paid at the sole expense of customer.
20. For any work or workmanship that allegedly or rightfully requires remedy (per city ordinance or customer request), customer agrees to allow i" Priority Roofing and any of its agents or
subcontractors full access to the property in order to complete such remedies. Any remedy shall be completed at the sole discretion of 1" Priority Roofing executive management (if at all), and
done per 1" Priority Roofing's own timetable and construction practices and materials. Customer agrees to a schedule of remedy chosen by 1" Priority Roofing, should 1" Priority Roofing deem
a remedy necessary. Should the customer decline to allow 1" Priority Roofing or its chosen agents to remedy its own work or workmanship, or decline (or delay) the schedule outlined by 1"
Priority Roofing, all outstanding balances and applicable attorney or collection fees shall become due in full immediately without penalty to 1" Priority Roofing and any or all remedy work shall
be constituted as fulfilled by 1" Priority Roofing, furthermore, customer agrees to (at their own expense) work with the city to complete repairs required to close outstanding permits.
21. Customer will hold all insurance monies received by Customer for the performance of Contractor's work solely and exclusively for the benefit of Contractor. Owner understands and agrees that
any funds related to the Project received by Owner from a lender or insurance company, or intended to pay all or part of the construction costs, are held in trust for payment of Contractor's
labor and materials. In that respect, Owner has the same duties and liabilities as a general contractor to hold the funds in trust for payment of Contractor. Using the funds held in trust for any
purpose other than payment of Contractor makes Owner liable for treble damages under Colorado law.
Corporate: 7208 S. Tucson Way, Ste 195 / Centennial, CO 80112. Info@1stPriorityRoofing.com
Denver ('120) 271-3718 1 CO Springs (719) 646-0968 1 FT Collins (970) 817-6154 1 V1.2017
qX .. G�CLI 2 Q n L
a < c (please print):
Address: =iOr"e—
City, State, Zip:
OEM NMI'
2=
[IT,
City License # City License # City License #
Can t Value of all w*rk:
CI
Review Fee (due at time of submittal):
Squares
BTU's Gallons
Amps Sq ft
$
APPROVAL X SIGNATURE
COMMENTS: WsTOTAZL-
- 7 -SUBTOTA �JS�eo
. ........ ..
INSPECTION RECORD Occupancv/TVpe
INSPECTION LINE: (303) 234 -5933
Inspections:will not be made unless this card is posted on the building site
Call by 3:00 PM to receive inspection the following business day.
l 0 3PI
INSPECTOR MUST SIGN ALL SPACES PERTAINING To THIS JOB
FOUNDATION INSPECTIONS DATE INSPECTOR
INITIALS
COMMENTS:
Footings /Caissons
Stemwall / (CEG) Concrete
Encased Ground
Reinforcing or Monolithic
Weatherproof / French Drain
Sewer Service Lines`
Water Service Lines
-POUR No CONCRETE UNTIL
ABOVE HAS BEEN SIGNED
` CONCRETE SLAB FLOOR
Electrical (Underground)
Plumbing (Underground)
Heating (Underground)
-Do NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED
IkOUGHS
S heathing
:Lath /Wall tie
t Mid -Roof
x�.Electrical Service;
Rough El�eErrc
RougftKPlumbing
` Gas,} Iping
Rough Mechanical ,
ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING
Framing
I � l l — l .
OCCUPANCY NOT;PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED
y PROTECT THIS 6 ARD FROM THE WEATHER
♦ i CITY OF WHEAT RIDGE
�� Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office • (303) 237 -8929 Fax
INSPECTION
j � NOTICE
PV
Y Tvnp- , ! , (<liP� Y�
Job Address: Uk e i;_ qq
Permit Number: C )Q Uhln a
l �f�`dfi3d F TOK
❑ No one available for inspection: Time `3 AM PM
Re- Inspection required: Yes
"When co
# 7i rrections have been made, cal re -in ec t } ion a�03- 34-5933
Date: i ' cq Inspector: I rYx.+r , it�� Pay F /
-
DO NOT REMOVE THIS NOTICE
e A i CITY OF WHEAT RIDGE
r Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: 2 rZ
Job Address:
f~ 9 i - X99 1 ~r s~>'
Permit Number: /00,3ci9
❑ No one available for inspection: Time AM/PM
Re-inspection required: . Yes No
*When corrections have been made, call for re-inspection at 303-234-5933
Date: a " Inspector:
DO NOT REMOVE THIS NOTICE
e i CITY OF WHEAT RIDGE
d ' Building Inspection Division
( (303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: ✓ Z
Job Address:
Permit Number: /UO
-2~0 5X ZI- //(77 M A,,~,~
❑ No one available for inspection: Time AM/PM
Re-Inspection required: Yes No
*When corrections have been made, call for re-inspection at 303-234-5933
Date: M, ` /O Inspector: 21/
DO NOT REMOVE THIS NOTICE
i
~OF WF1EATq,O City of Wheat Ridge Building Division Date:
m 7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 ~ Fax: 303-237-8929 Plan
o Inspection Line: 303-234-5933
ocoRro Permit#:
Building Permit Application
Property Address; 7C 05- 4~~!M C G~ 11 , :s01i 3f ~03
Property Owner (please print):
Mailing Address: (if different than property address)
Address:
City, State,
w el r K' /1411, 3
Contractor: "Q2-/Z (n~
Contractor License Phone: 30-7 ?-zz- 5.~`
Sub Contractors:
Electrical City License
Company:
Plumbing City License
Company
Mechanical City License
Company:
Exp. Date: Exp. Date: Exp. Date:
Approval: nn Approval: Approval:
Use of space (description): /~1p ~C O fie ! ®CL/I B. Construction Value: 8lSlJl1 A2,r 'Y
Description ofmorki (as calculated per the Building Valuation Data sheet)
1 ~t Plan Review (due at time of submittal): $
PaiIc 17 I`n -05 P- S
Sq. Ft./L.Ftadded: Squares BTU's Gallons Amps 1620
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work
under this permit. Plans subject to field inspection.
CIRLCE ONE:: {(OWNE/R) (CONTRACTOR) or PERSONAL REPRESErHATIVE of (OW,NNE~R)) (CONTRATOR)
I --1e PRINT NAME: SIGNATURE: `49/ 1 Jr" Date tZ
Phone: ~r
s,• . ar .rr x..+P. :..~..i~ ,.::.r..e ,.+.,,.snw~..sy.a-..b,._..,..F- M.: a=~. ~:^..Y
e A s CITY OF WHEAT RIDGE
° Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: 6 i V~, t
Job Address: c1S ~~4 F t`~Sl3~
L~t(~
Permit Number:
3
t
ff
I
❑ No one available for inspection: Time /PM
Re-Inspection required: Yes--duo
When corrections have been made, cab for re-Inspection at 303-234-5933
J
Date: Inspector:
DO NOT REMOVE THIS N TICS
City of Wheat Ridge Building Division 9 Date:
" 7500 W. 29" Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-235-2857 Plan
cOCORro° Inspection Line: 303-234-5933
Permit
Building Permit Application
P;ropeit~;q~dres'sw ~E 9 S~ ,
Property Owner (please print): 0 e 6f ,u Phone: - - `/23 - 8 9 q3
Mailing Address: (if different than property address)
Address: e
City, State, Zip:
cagtt~xto~: ~dUr,~r~ced ~x~er'r6~5
Contractor License Phone: 3D3 ~~(D CP~32
S16 Contraetot~„
Electrical City License Plumbing City License Mechanical City License
Company: Company Company:
Exp. Date: Exp. Date: Exp. Date:
Approval: Approval:
Approval:
Use of space (description): ~e_ C>U F Construction Value: S_ ro L7 0 O
I]e"scrlpYJJJlOn~~}tI~/Oftc (as calculated per the Buildin Vafua6on Data sheet)
~ Y Plan Review (due at time of submittal): $
VV c-T 1. Ls~ 1"v ~7r~/
Sq. Ft./L.Ft added: Squares 3 S BTU's Gallons Amps
OWNER/ CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work
under this permit. Plans subject to field inspection.
C/RLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR)
PRINT NAME: Q0 SIGNATURE: 7LS~~-+ Date: Z 11 b/O`Y
Bldg