HomeMy WebLinkAbout10285 W. 33rd AvenueFrom: no-reolv(alci.wheatridae.m. us
To: CommDev Farm is
Subject: Online Form Submittal: Residential Egress Window Pennit Application
Date: Friday, August 20, 2021 1:52:19 PM
Residential Egress Window Permit Application
This application is exclusively for RESIDENTIAL EGRESS WINDOWS ONLY.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORMAN D
ENGINEER LETTER STAMPED DETAIL SHOWING THE U -VALUE OF THE
WINDOWCUT IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit
will be emailed to the email address provided below once it is processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for Yes
existing EGRESS
window(s) needing
vertical cuts only?
PROPERTY INFORMATION
Property Address 10285 W. 33rd Ave Wheatridge, CO 80033
Property Owner Name Andrea & Brett Casso
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email
Address - Do not enter
a contractor email
address
Attach City of Wheat
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
0L81YIil.7iCIM11
andreakcasso@gmail.com
Electron ic-Payment-Form. Odf
CONTRACTOR INFORMATION
Contractor Business FTC - FINAL TOUCH CONSTRUCTION
Name
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Person Applying for Glen Bullock
Permit
Email not displaying correctly? View it in your browser.
Contractor's License
021734
Number (This is a 5 or
6 digit number for the
City of Wheat Ridge)
Contractor Phone
303-321-8884
Number (enter WITH
dashes, eg 303-123-
4567)
Contractor Email
EMILY@FTCDREAMS.COM
Address
Retype Contractor
EMILY@FTCDREAMS.COM
Email Address
01:K161CiI91 ffl0N]&TO(6]N:/
Number of EGRESS 2
windows being
replaced
Location of EGRESS Basement North Wall & Basement West Wall
window(s) being
replaced (for example,
master bedroom,
kitchen, bathroom, etc):
What is the u -value of .30
the EGRESS
window(s)? City of
Wheat Ridge requires
the u -value to be .30 or
better on windows.
Attach copy of Window eaaress - letter docx
Engineer stamped
letter showing vertical
cuts detail and u -value
Project Value (contract 5500
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
City of Wheat Ridge
/0' Residential Roofing PERMIT - 201702292
v/
PERMIT NO: 201702292 ISSUED: 06/21/2017
JOB ADDRESS: 10285 W 33rd AVE EXPIRES: 06/21/2018
JOB DESCRIPTION: Residential re -roof to install asphalt shingles - 24 sq.
*** CONTACTS ***
OWNER (303)204-3896 SAWYER JEREMY S
SUB (303)756-7663 Ty Correy 090134 Advanced Exteriors, Inc.
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 19,000.00
FEES
Total Valuation 0.00
Use Tax 399.00
Permit Fee 346.95
** TOTAL ** 745.95
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding A% -inch exists. Asphalt shingles are required to
be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is
required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturera€TMs installation
instructions, whichever is more stringent. In order to pass a final inspection of
elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer's technical representative stating that "the application of the roof at
(project address) has been applied in accordance with the installation instruction for
(roof material brand name) roof covering" is required to be on site at the time of final
inspection.
City of Wheat Ridge
.
Residential Roofing PERMIT - 201702292
000-1
PERMIT NO: 201702292 ISSUED: 06/21/2017
JOB ADDRESS: 10285 W 33rd AVE EXPIRES: 06/21/2018
JOB DESCRIPTION: Residential re -roof to install asphalt shingles - 24 sq.
I by my signature do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am tie legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved. in conjunction with
this ermit. I further attest that I am leggally authorized to include all entities named within this document as parties to the work to be
performed and that allll)work to be perfonned is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNS or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalppermit fee.
3. If this permit expires, anew permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for or an approval of, any violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is'subject to field inspection.
t +►
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us
between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line.
Air
Advanced Exteriors, Inc.
EXTEittORS —T—
Propetly --"sl capsramer
proposal Date
-;r.P"
Address 0
Primary Fhzme
o -
City, SIC* Zia
Soc�ndq Phase
1nM=nC& compmy claim
Emag Addirm
Znsplact decking F] install declog
tall toe and water shield on 4 44
install 15 # felt Install 3-0 # felt
install premium synthetic cieck, protection
z
install starter course of si-ingles-entile perkneter
install drip sice perinnetet noshing - color
-,,-TnsfaJ1 reinforcement in valleys using
-I.Closed vo$eW ❑ open valleys
Replace step flashing on sidewalls, Ovirnney and skylights
Install 6 nail's pet s" throtrgf out
owo,
Roofing productlay. P
Roofing color
ManufactureirWaranty
Special 1ns'Tucfions/Addt¢c,-4i
I
Standard r'.'dge High pronle ridge
Install Ildly.
vent
Install turtle vents Mln—slcrl-1, -,379 Fes., vents
instars pipe lock floSnIngS Ej rstall furnace caps
?Ont JGCk441'acks to 7nntch roofing co'
Detach andresei
Remove and cover
,lilstoll beout� course of ridge Shingies on heodwalls
eeOeeh erid-mqel� �, � :Ove satellite
Zfean up & remove trash p Yvitt-, magnetic roller
Prow
, r"4'
Clean W guttersProAde building permit
Register Nilanufacli iter Warranty
Advun(;eci Exteriors, Inc, Five Yeas Roofing toloo; Warranty
Advanced E>rteTlom Inc, $2-000,000 Liab-4tv Insu=ce
44
7
APPTOldnwta DOM$) of Se Ace: 7 Payment Terms: L
)Advanced Wenors, Inc. Is not M;PWMAW& (Or *"YPrqwwfil and dasuawy Insurance WMWJ deWcr denial of Inswance claim, Inwriaile arin pert),
X4—
Wtlik Corn Rated ill, accOrdonce W,1h these Specifications for the rt; -,e of:
Dollars
L:'>,j The P'c Oo Ownells) l'CLZt0M&") OIlhor[m AdvCrced ExoriM Inc. tornpmn 10 WCAwil-, t)al rasonce caner to odain " 5W w,(Xx-, of
ref on neces=y fa iesforaxn of Wm clarnoge, This -,Aqee-,ierd- r, not t a CaTpary Lx)t% ". irajo-ce caw qpao�vs
Cpr's Clam end this OMO,;--,t is OccepW by CorMry, Wan occepiance tN CornparN, the arro.j OPPR7"w by theinFarce CITOW VAU
ODCare " Ird CCM=t =e aria Company YA eecwe the mucince pioceeds ftsAot I hos corrolairW, Thq Corro
work f to CIDOVOnCl ln�a 09MOd C&'n arnuall INCept for the Mmnce dedILPMle , orywo c-TOet9 specified
- rat frrOndrg tO -KAO POVMOrt from the proceeds of a omparly and cosiGity ir,&,irox-e oDgr-v It CLwog7 �- parvnt is from an
nsLMMe C bm' frA-. pas --'w to Cobrow Ow '00-v any (Wfin;i 'w"Wal 'sna rof WA Ow Cq pnxnw to pay, wave Q� eb Ve j I I ( Y pat of any
CAS,§6,22-105,71neCowpony &1a
ti -Ad in trust any pertrr-&-,t w, -, ed ftom, C"1P#1 Corroanj les deliveed ", to to Ciistorws propety 0, ~. Cor=ry hm
reffori-ed om,*Myof the ' AcAon C,;s1riTos uoo"
By signing low I (47/p) agree to a# contract conclitilons, on front and back of this agreement, and have been provided
notice orf ti
Accopliwwo Date
2200 S. Valley Hwy. 303-766-ROOF(7663) Offico
Denver, CO 80222 www.AdvancedWedors.com 303-756-3756 Fay,
Antoinette Kulick 7
From: no-reply@ci.wheatridge.co.us
Sent: Monday, June 12, 2017 3:1 S PM
To: Permits CommDev
Subject: Online Form Submittal: Residential Roofing Permit Application
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT
IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME
WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your
contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit. Permits are currently being
processed within 3-5 business days, subject to change based on volume.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number
Property Owner Email
Address
Do you have a signed
contract to reroof this
property?
It will need to be
provided at the time of
permit pick-up.
10285 W 33rd ave
jeremy sawyer
303-204-3896
Field not completed.
Yes
$ � q�-. 07�-
CONTRACTOR INFORMATION
Contractor Name
Advanced exteriors
Contractor's License
090134
Number (for the City of
Wheat Ridge)
Contractor Phone
303-725-4502
Number
Contractor Email Address
freddygreen@advancedexterior.net
(permit pick-up
instructions will be sent
to this email)
Retype Contractor Email
freddygreen@advancedexterior.net
Address
DESCRIPTION OF WORK
Is this application for a
Yes
new permit for a
residential roof?
Are you re -decking the
No
roof?
Description of Roofing
asphalt
Material
Select Type of Material:
Asphalt
If "Other" is selected
Field not completed.
above, describe here:
How many squares of the
24
material selected above?
Does any portion of the
No
property include a flat
roof?
If yes, how many squares
Field not completed.
on the flat roof?
TOTAL SQUARES of all
24
roofing material for this
project
2
Provide additional detail timb hd, 130mph, 3/12 pitch
here on the description of
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
Project Value (contract 19,000
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant Freddy g
Email not displaying correctly? View it in your browser.
3
INSPECTION RECORD
Inspection online form: http://www.ci.wheatridge.co.us/inspection
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site
Request an inspection before MIDNIGHT (11:59 PM) to receiveAn ins ction the following business day
PERMIT: O A�-ADDRESS: �,J . �'Q�, , JOB CODEKIC-L
Its
Foundation Inspections
Date
Inspector
Initials
Comments
102 Caissons / Piers
103 Footing / P.E. Letter
104 Foundation Setback Cert.
105 Stem Walls
106 Foundation wall Insulation
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground / Slab Inspections
Date
Inspector
Initials
Comments
201 Electrical / Cable/ Conduit
202 Sewer Underground Int.
203 Sewer Underground Ext.
204 Plumbing Underground Int.
205 Plumbing Underground Ext.
206 Water Underground
f
Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections
Rough Inspection
Date
Inspector
Initials
Comments
301 Rough Framing
302 Wall Sheathing
303 Roof Sheathing
304 Sheer Inspection
305 Insulation
306 Mid -Roof
307 Metal / Lath / Stucco
f
308 Rough Electrical Residential
309 Rough Electrical Commercial
310 Electrical Meter Residential
311 Electrical Meter Commercial
312 Temp. Const. Meter
313 Rough Plumbing Residential
314 Rough Plumbing Commercial
315 Shower Pan
SEE OVER FOR ADDITIONAL INSPECTIONS
PERMIT50I I D&O'ADDRESS
N26d,, 4 JOB CODE:Q�L
Rough Inspection (continued)
Date
Inspector
Initials
Comments
316 Rough Mechanical Residential
317 Rough Mechanical Commercial
318 Boiler / Furnace
319 Hot water tank
320 Drywall screw and Nail
321 Moisture board / shower walls
322 Rough Grading
323 Miscellaneous
Final Inspections
Date
Inspector
Initials
Comments
402 Gas Meter Release
403 Final Electrical Residential
404 Final Electrical Commercial
405 Final Mechanical Residential
406 Final Mechanical Commercial
407 Final Plumbing Residential
408 Final Plumbing Commercial
409 Final Roof
410 Final Window/Door
411 Landscape/Park/Planning*
Inspections from these entities shall be requested
one week in advance.
*For landscaping and parking inspections please
call 303-235-2846
**For ROW and drainage inspections please call
303-235-2861
***For fire inspections please contact the Fire
Protection District for your project.
412 Row/Drainage/Public Works**
413 Flood plain Inspection**
414 Fire Insp. / Fire Protection***
415 Public Works Final**
416 Storm Water Mgmt.**
417 Zoning Final Inspection*
418 Building Final Inspection
Note: All items must be completed and approved by Planning, Public Works, Fire and Building
before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not
constitute authorization of occupancy.
For Low Voltage permits please be sure that rough inspections are completed by the Fire District and
Electrical low voltage by the Building Division.
City of Wheat Ridge
Residential Roofing PERMIT - 201702292
PERMIT NO: 201702292 ISSUED: 06/21;2017
JOB ADDRESS: 10285 W 33rd AVE EXPIRES: 06/21/2018
JOB DESCRIPTION: Residential re -roof to install asphalt shingles - 24 sq.
**REVISION**Using concrete tiles; No added Valuation; Engineer's letter on
file
*** CONTACTS ***
OWNER (303)204-3896 SAWYER JEREMY S
SUB (303)756-7663 Ty Correy
090134 Advanced Exteriors, Inc.
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 19,000.00
FEES
Total Valuation 0.00
Use Tax 399.00
Permit Fee 346.95
** TOTAL ** 745.95
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding A/2 -inch exists. Asphalt shingles are required to
be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is
required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturera€ms installation
instructions, whichever is more stringent. In order to pass a final inspection of
elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer's technical representative stating that "the application of the roof at
(project address) has been applied in accordance with the installation instruction for
(roof material brand name) roof covering" is required to be on site at the time of final
inspection.
City of Wheat Ridge
Residential Roofing PERMIT - 201702292
PERMIT NO: 201702292 ISSUED: 06/21/2017
JOB ADDRESS: 10285 W 33rd AVE EXPIRES: 06/21/2018
JOB DESCRIPTION: Residential re -roof to install asphalt shingles - 24 sq.
**REVISION**Using concrete tiles; No added Valuation; Engineer's letter on
file
I by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal
,policies and procedures, and that 1 am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction w ith
this permit I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of QUER or CONTRACTOR (Circle one) Date
I . This permit was issued based on the information provided in the pen -nit application and accompanying dans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans
and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new pen -nit shall be subject to the standard
requirements, fees andprocedures for approval of any new pen -nit. Re -issuance or extension of expired pen -nits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4 No work of any manner shall be performed that shall results in a change of the natural flow of water without prior andspecific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable lVdc of any ordur e or egu tion of this jurisdiction. Approval of work is subject to f�eld inspection.
MAI
Signature
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us
between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line.
City of
WheatRjq C
COMMUNITY DEVELOPMENT
Building & Inspection Services Division
7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: permitsCd)-ci.wheatridge.co.us
FOR OFFICE USE ONLY
Date:
Add to Permit #
Building Permit Revision/Amendment Application
*** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ***
Property Address: 10 LS !� 11v. Q Je i,)e
Property Owner (please print): 5er2kl^� 5 w ye! Phone: So?-Zoy -ia96
Property Owner Email:
Mailing Address: (if different than property address)
Address: Sri,' e -
City, State, Zip:
Submitting Company:
Contact Person: Fcedcr y G ce e n Phone: 3413 - 125'- NSDz
Contractor: 14d ✓�vlCP d I-A}Q c, o fs'
Contractors City License #: -015-10 k W Phone: 3 oS 75to - 7b 3
Contractor E-mail Address:
Please Note: Additional valuation must include all general and subcontracted work to be performed
related to the revisions and/or amendments declared in the description of work and which were not
included in the original permit valuation.
If revisions or amendments increase the original valuation, additional fees will be due at the time of
approval. Depending on the scope of work, additional plan review fees may be due upon approval
($60.00 an hour — 2 hour minimum).
Description of revised/amended work:
Sq. Ft./LF
Amps
Btu's
Squares
Gallons
Other
Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above)
6f, 00
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application.
CIRCLE ONE: (OWNER) (C�R) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)
PRINT NAME: 6xc, ✓1 �l�1 �� SIGNATURE: �1yz �/L � � DATE:
ZONING COMMMENTS:
Reviewer:
BUILDING DEPARTMENT COMMENTS:
Reviewer
PUBLIC WORKS COMMENTS:
Reviewer:
PROOF OF SUBMISSION FORMS
Fire Department ❑ Received ❑ Not Required
Water District ❑ Received ❑ Not Required
Sanitation District ❑ Received ❑ Not Required
DEPARTMENT USE ONLY
OCCUPANCY CLASSIFICATION:
Building Division Valuation: $
ONSTRUCTION
U PPORT
ERVICES, INC.
DATE: June 5, 2017
HOMEOWNER: Ms. Jessica Sawyer
10285 W 33rd Ave
Wheat Ridge, CO 80033
CONTRACTOR: Advanced Exteriors
INVOICED TO:
ROOFING SYSTEM: Concrete Tile
Roof Framing Loads: Live and Dead Loads
Item
Weight (psf)
Source
Snow Load
30
Local Code
Roofing Weight
11
Manufacturer
Misc (sheathing, insulation, etc.)
4
Standard weights
Total (psf)
45
Rafter Spacing (inches)
24
Measured value
Top Chord Loading (per linear foot)
90
Calculated value
Wind Loading: Attachment shall meet 2012IBC, 2015 IRC or 2015IBC based on local requirement
Design 100 mph(ASD) Exposure C Less than 40' One fastener per tile.
Velocity ! high
100 mph(ASD) Exposure C 40'-60' high The head of all tile shall be nailed. The nose of all
eave tile shall be fastened with approved clips. All
rake tile shall be nailed with 2 nails. The nose of
all ridge, hip and rake tiles shall be set in a bed of
roofer's mastic.
For velocities in excess of 100 mph(ASD)
attachment shall follow manufacturer's
Evaluation Report
Note: Table has minimum requirement. This is an ultimate wind velocity of 130 mph
This house was examined with the intention to install a new concrete roofing tile system
on the house. We examined the attic to see the roof supports, the house for existing
drywall cracks or other evidence of movement. There are always areas that are not
observable and we attempted to determine the framing method in those locations.
Project: 10285 W 33rd Ave, 80033
Page 2of2
Using the information we collected we were able to model the support system in this house.
That model for the framing assuming no stiffening effect form the cross -tie, looks like this:
This is acceptable.
When the roof is torn off, the roof deck should be checked to verify that the sheathing is
nailed using 1 fastener every 6" along the seams and 12" on -center in the field of the
sheathing.
Please note, anytime you reroof there is a rapid change of loading as the old roof is removed
and the new roof installed. This change in loading, movement of materials and men, and the
pounding that occurs, can cause small drywall cracks. These are not structural. If any
cracking is observed, please call our office so we can make sure that there is nothing else that
may have occurred.
There was no significant storage in the attic space. It is assumed that no additional storage
will be done in the attic. Loading the bottom chord of trusses can change their behavior. If
heavy items are to be stored in the attic consult with CSS, Inc. to make sure the loading is
acceptable.
This opinion is based on the conditions observed. There are sometimes areas of framing that
are not observable. Calculations for acceptability are based on the conditions observed using
current versions of analysis software. Change of use or loading by conditions outside of those
observed can change the results of the analysis. Alterations to the framing will require a new
analysis.
This hous _LLP'
i
%�>_•7901 S ADAMS WAY 303-221-1559 CENTENNIAL, CO 80122
NAL -
Liitertt Niutua!
1O Box 515097
s�.auxe�sca
1.Fii Atig ele;s, Cil 90051-5097
Fax. (8,48) 268-S
Duetting Line item Deta i
Soorr.tt - FA to View _ Siotrce - EngleView - Gutter
T)WFA LING
The yWue to the Additimai oolumn may cmit st of taxes, overheard and iatattt, art base srinace chargias W tabor mtn1mv-' a chames, as applicable,
kX13mles clepwation $eta um is r xriecnefee r e
WR 1Y -S -SAWYER -&-JE 51t9l2e[17 F'a$e; .1
F,stivaute
Rtoact rnt
[mss
Actual Casio
k t iii to ct
ieatrnaaat. Arhiidanit �
Cost Value
Ginn
valuis
Source - Eo& View - S"ree -Eagle View 2k2
CX'.L'E:i..F:I' Ks
I. emsxr.StreltilrAhsie. 1-4,94 SO 'S'?6,I0
$1.8117.613
511(5)
$1.1$9793
$01(*
$i,S97.'i3
giarular CYrsivj - with [Olt
iec adca Dump teca, hauling, ah-v€aal' tow a to tcatvvc stcrl tilc rararirng
and Tek.
2. 5tea1 tile."st ite - ittimuta r 2'.44 SO j;W.1t1
$15w588.E6
54(1'3.114
516JA7:71
S1,€S050il
514.451.93
coatm - w1ma a felt
[ncludch: Steel tales.. telt, fasteners, and imtellatinn ids.
QUillity: d. ramikir`c4sutii3 heti 1i1A�4hike1shingle style.,
'This line item) m n nks it d6tagle rruitwial allowavve of $1924 7tr per sqt which artiectscumin rawket pri"s to yaau �- Mariet prieGs e'w'e teritiva by
AladSlcy`s Managed Material Program The ktaira'k'y i4lattrEat l�metwsirn
[%ovant Sll Coe you
n yatrt S ost rk cum o1 di'vi'v U, have rsiatcrt.al
-livered
dtrcctly to your hums- fitw instailati€ w Far mtvc wformaliim tem M;jdSky -ttatacj them at: �CnS'et�
@#i?� �
l ) U�Yftk
tdr3� 4 at M-94 -2444 ext 265.
ktt`[lm" 19•x: waot
3 ltcarl"itar telt • 15 lb. win SO 527."
5'675..17
1ilWP
$496.44
-$14Cr:61
54°19,x2
4, Ice & wilier shiehl 43KW SF 51.63
$722.70
$13,32
$ 7:16-tg2
-$112.117
$613::15
5, Steel tikishalce - ridge or 74532 LF 59,04
STi76.?7
$2$. ,43
8704.10.)
$7tl.dt3
sk ld.12
[tile- 8ranolar c(tated
6. R€wfi g .. Qcncrri 0.50 HR $42.463
S21 25
Sd) 00
823.25
1,4100
$21,25
l.. a7rei' - per hitt
in0vt and rexcl hasket Ball lure river 8art[re, atulcheit tri tea*,
�I
iidccr¢talrrrserunitametaltop l,{i F $%),Io
$90.16
WAD
$alt,10
d).
521(1,1(1
P-1
laa� Retrtt6'L.(.'114uee' IAD FA $21,35521.
C
$.�
d e
5(l.tkl
[
5>l.?
•�''+tl.tlt
$21.%:S
dashing - jat`�t (K' x 60*i
St/. 1 unstrey' t'S+2-'4h2ng ,. i JX) EIN i.'2:C4
S:i.T..2.1'4i
.' (r..tR�
S•i-28,6
- 1,
'5,,367 *1A
laree•. e32" .Y. 60'ji
'i. pc -rf v:jat .,. wriic type - 8,00 EA $50,17
$401.36
S9:22
$41:€13(3
-5158-
$15192
4irial
111, Exhaust, cap- thoingh 1,1P EA P.3,x6P
57389
S214al
$763?
-5111_. 1
W.46
11.Flashing ,opelack - 2WFA $0.1
SQ&18
S4<ia'
Sl:§i:SEi
-s48.7
$11271
spilt tu,crt
Subtotals -Source - Eager View -:Sour" - Ea r View
520;617.30
5.54:5A2
$2l,10.72
.$21 +.1.14
$19.067„59
Soorr.tt - FA to View _ Siotrce - EngleView - Gutter
T)WFA LING
The yWue to the Additimai oolumn may cmit st of taxes, overheard and iatattt, art base srinace chargias W tabor mtn1mv-' a chames, as applicable,
kX13mles clepwation $eta um is r xriecnefee r e
WR 1Y -S -SAWYER -&-JE 51t9l2e[17 F'a$e; .1
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: Vo q 90 F
Job Address: 1 U J-1-,9 17 V 3 3 f�vL
Permit Number: ,-0/ 70,;, P� X
❑ No one available for inspection: Time AM/PM
Re -Inspection required: YesNo �—
When corrections have been made, c for re -inspection at 303-234-5933
Date: 10/5/-/7 Inspector: T#
DO NOT REMOVE THIS NOTICE
(`
41
CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:��
Job Address: Z S w
Permit Number: -, � 2Z Z1/ /L
❑ No one available for inspection: Time '
1 -_ /PM
Re -Inspection required: Yes �o J
'When corrections have been made, call for re -inspection at 303-234- 933
Date: / �~ 1 / % Inspector: /��r(�
DO NOT REMOVE THIS NOT/CE
INSPECTION RECORD- � ��C Upancv/TVu
INSPECTION LINE: (303) 234 -5933
Inspections will not be made unless this card is posted on the building site I
Call by 3:00 PM to receive Inspection the following business day.
INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOE
FOUNDATION INSPECTIONS
DATE
INSPECTOR
COMMENTS:
Plumbing (Underground)
INITIA
Footings /Caissons
-
Stemwall / (CEG) Concrete
POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED
_
ROUGHS ,
Shea
Encased Ground
(,
— _
Lath / Wall tie -
Reinforcing or Monolithic
Mid- Roof
Weath erproof / Fr ench Drain
,
Electrical Service
Sewer Service Lines
OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. ._. ..
-
WaterService
Rough Plumbing
PI III N! r( MN DRTR I IUTII ARn1 tp HGG RFFN.
CONCRETE SLAB FLOOR
Electrical (Und erground )
-
1
- -i
Plumbing (Underground)
Heating (Underground)
DO NOT
POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED
_
ROUGHS ,
Shea
Fire Department
(,
— _
Lath / Wall tie -
R.O.W & Drainage
Mid- Roof
`(���
,
Electrical Service
CERTIFICATE. OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES Nor CONSTITUTE AUTHOFdIZATION
OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. ._. ..
Rough Electric
Rough Plumbing
Gas Piping
Rough Mechanical
ABOVE INSPECTIONS TO BE
SIGNED PRIOR TO PROCEEDING
Framing
Insula
Drywall Screw
FINALS
—I
--
E lectrical
Plumbing
1
- -i
Mechanical
Roof
Building Final
w
Fire Department
R.O.W & Drainage
INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUSUCE WORKS
SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS.
Parking & Landscaping
"'NOTE: ALL ITEMS MCQ BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS 6EFORE A
CERTIFICATE. OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES Nor CONSTITUTE AUTHOFdIZATION
OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. ._. ..
OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED
PROTECT THIS CARD FROM THE WEATHER
CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office . (303) 235 -2857 Fax
INSPECTION NOTICE
Inspection Type: 1 'eJ
Job Address /Permit Number: /(%ry��5 �7 ',
r
lot
r r ,
❑ No one available for inspection: Time 3' AM/�M
Re Inspection required: Yes No a
* When corrections have been made, call,, #or re -in ection at 303 - 234 -5933
E 7 �^ l ip r A
i
Date: `fC�'O Inspector:
DO NOT REMOVE THIS NOTICE
♦ i CITY OF WHEAT RIDGE
Building Inspection Division
~r (303) 234-5933 inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address: tt~~g.~ ~i, ?3Y a
Permit Number: Oq cpo;' W
r
❑ No one available for inspection: Time Aw'pm
Re-Inspection required: Yeso
When corrections have been made, call for re-inspection at 303-234-5933
Date: Inspector: r L i
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge
]~;'r Residential Roofing PERMIT - 092024
PERMIT NO: 092024 ISSUED: 09/04/2009
JOB ADDRESS: 10285 W 33RD.AVE. EXPIRES: .03/03/2010
:DESCRIPTION: Reroof 29.6 sqs
CONTACTS
'owner 303/238-0726 Allen Salzmann
sub 303/425-7531 John Borfitz 01-9983 J & K Roofing Inc.
* * -PARCEL INFO * * -
sZONE CODE: UA USE: UA -
SUBDIVISION: 0646. BLOCK/LOT#.: 0/
FEE SUMMARY ESTIMATED. PROJECT VALUATION: `21,468.00
FEES
Permit Fee 454.10 e
Total Valuation .00 . ..386.42 Use Tax i
**TOTAL 840.52 Yao`. "xisw,'.M
)onditions:
> nail installation & mid-roof inspection required. Board sheathing spaced more
.han al/2 of an inch apart requires plywood overlay on entire roof. Ice. and
vater shield required from eave edge to 2' inside exterior walls..
subject to field inspection.
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable
ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all
measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this
application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C). and all other
applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection..
d 9-4-0q-
Signature of co ractor/owner date
. ..This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the
State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable
ordinances of the. City. - -
This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration
date. An extension may be granted at the discretion of the Building Official.
If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no
changes have been or will be made in the original plans and specifications and any suspension or abandonment has not
exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall
be paid for a new permit.
No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractorshall notify the Building inspector twenty-four (24) hours in advance for all inspections and shall receive
written approval on inspection card before proceeding with successive phases of the. job.
The issuance of a permit or the approval of drawings and specifications shall not be construed to be apermit for, nor
an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation.
All plan review is d~Mect to field inspections.
Lgnature of C e u'ilding Official date
NSPHCTI REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855
EQUESTS :MUST BE MADE BY:.3PM ANY BUSINESS DAY FOR 'INSPECTION. THE FOLLOWING BUSINESS DAY.
~pF WH~T.p .
v ~ m
c~CORA~~
City of Wheat Ridge Building Division
7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 " Fax: 303-235-2857
Inspection Line: 303-234-5933
Date: (7q
Plan
P,ermit 0 q- 'r
Building Permit Application
ra ?-D
Property Owner (please print).4k t,(71\1
Mailing Address: (if different than property address)
Address:
Contractor License
SEEKS=
Electrical City License
Company:
Exp. Date:
Plumbing City License
Company
Exp. Date:
Mechanical City License
Company:
Exp. Date:
Use of space (description): N C-- I- AYVI ~ I Construction Value: $ ~t i ~tL
L (as calculated Oar the Building Valuation Data sheet)
SRh
Plan Review (due at time of submittal): $
c r ~ 1 _PA 31Z `l V~~LY
Sq. Ft./L. Ft added: SquaresC29,(OBTU's Gallons Amps
OWNER)CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application aye accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurement9~-shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that l assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work
under this permlt. Plans subject to field inspection..
CIRLCEONE:: (OW ER) (c10 RACTOR) PERSONAL REPRESENTATI of(RWNER ONTRATOR)
PRINT NAME: 'Ken V, --S{GNATVRE-.-"-'-' - / bate: 4Z,0-10