HomeMy WebLinkAbout3292 Simms Street1* ► � i City of Wheat Ridge
'/� Residential Foundation Repair PERMIT - 201902265
PERMIT NO:
201902265
ISSUED:
10/24/2019
JOB ADDRESS:
3292 Simms St
EXPIRES:
03/04/2021
JOB DESCRIPTION:
Foundation repair - 4 helical piers
and 5 carbon
strips
*** CONTACTS ***
OWNER (303)345-7918
SH I EH THERESA
SUB (303)805-8751
RODNEY MARTIN
060125 COMPLETE BASEMENT SYSTEMS
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE:
UA / Unassigned
SUBDIVISION CODE:
2403 / APPLEWOOD
VILLAGES, PROSPECT
V BLOCK/LOT#:
0 /
*** FEE SUMMARY ***
ESTIMATED PROJECT
VALUATION:
91810.00
FEES
Total Valuation
0.00
Plan Review Fee
132.80
Use Tax
206.01
Permit Fee
204.30
** TOTAL **
543.11
*** COMMENTS ***
*** CONDITIONS ***
Approved per plans and red -line notes
on plans. Must
comply with
2012 IRC, 2017 NEC and all
applicable City
of Wheat Ridge Municipal Codes. Work
is subject to field inspections.
I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications,
applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any
�pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
10/24/2019
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
♦6 A♦
City Of
19cor eat dge
COMMUNITY DEVELOPMENT
CityofWheat Ridge Municipal Building 7500 W. 2u'Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929
Permit Extension Request Form
Permits expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in
writing and received prior to the date of expiration. An extension of no more than 180 days maybe granted at the
discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the original permit fee.
Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not
guaranteed. Please complete this form in its entirety and submit to the Building Division at
vermitsaci.wheatridge.co.us or fax to 303-237-8929.
Party requesting permit extension: Complete Basement Systems
Permit# 201902265
Property Address: 3292 Simms Street Wheat Ridge CO 80033
Phone # 303-805-8751 opt 2 Email Address: cbs.permits@completebasementsystems.net
Reason for extension request: Need to schedule final inspection if required and request to close permit
Number of days requested: 30-60
Printed Name: Cara Curry Signature: Cp2CL(247,Date: 2-4-2021
For office use only 11,,//''
This request has been: >(Approved ❑ Denied Extended until: 3/4/2021
Approved by: Date: 2/4/2021
www.d.whca dgexo.us
s_ CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: e � e f f
Job Address: C`l � __� M il-. S
Permit Number: Ou t C; L) �
a _ �
❑ No one available for inspection: Time I ry AM/PM
ss
t
Re -Inspection required: Yes" No
When corrections have been made, schedule for re -inspection online at:
http.11www.cLwheatridge.co.uslinspection
Date: � 0 � > i ; I a Inspector:
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type:
Job Address: -,Dc-) ��' r,. S
Permit Number: 0 U t Gi C)
❑ No one available for inspection: Time _ AM/PM
Re -Inspection required: Yes No
When corrections have been made, schedule for re -inspection online at;
http.-Ilwww.cLwheatridge.co.uslinspection
Date: v ) u - k '1 Inspector:
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge
Residential Foundation Repair PERMIT - 201902265
PERMIT NO: 201902265 ISSUED: 10/24/2019
JOB ADDRESS: 3292 Simms St EXPIRES: 10/23/2020
JOB DESCRIPTION: Foundation repair - 4 helical piers and 5 carbon strips
*** CONTACTS ***
OWNER (303)345-7918 SHIEH THERESA
SUB (303)805-8751 RODNEY MARTIN
060125 COMPLETE BASEMENT SYSTEMS
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,810.00
FEES
Total Valuation 0.00
Plan Review Fee 132.80
Use Tax 206.01
Permit Fee 204.30
** TOTAL ** 543.11
*** COMMENTS ***
*** CONDITIONS ***
Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
thispermrt. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signat' re of �O R or CON RACTOR (&ircle ne) %gate
I . This permt was sued based`o the information provided in the peit application and accompanying plans and specifications and is
subject to the co pliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Budding Official and is not guaranteed.
4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holy
der shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit spall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicable code orrdinance or r lation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Of ficial Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of
Wheat l�,
ComMUN ITy DEVELOPMENT
Building & Inspection Services Division
7500 W. 2911 Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: Permits(c)-ci.wheatridge.co.us
FOR OFFICE USE ONLY
Date: L h n ]
Plan/Permit # a o jq
J�
Plan Review Fee:
Building Permit Application
*** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ***
Property Address: 3292 SIMMS ST
Property Owner (please print): THERESA SHIEH Phone: 303-345-7918
Property Owner Email: THERESASHIEH(a)_HOTMAIL.COM
Mailing Address: (if different than property address)
Address:
City, State, Zip:
Architect/Engineer: DL ENGINEERING
Architect/Engineer E-mail: khoinessCa)_dlengineer.com Phone: 720-440-9450
Contractor: Complete Basement Svstems
Contractors City License #: 60125 Phone: 303-805-8751
Contractor E-mail Address: cbs.permits(a)_completebasementsystems.net
For Plan Review Questions & Comments (please print):
CONTACT NAME (please print): Sara Hasse Phone: 303-805-8751
CONTACT EMAIL(p/ease print): cbs.permitsC@-completebasementsystems.net
Sub Contractors:
Electrical:
W.R. City License #
Other City Licensed Sub:
City License #
City License #
Plumbing:
W.R. City License #
Other City Licensed Sub:
Mechanical:
W.R. City License #
Complete all information on BOTH sides of this form
❑ COMMERCIAL t? RESIDENTIAL
Description of work: (Check all that apply)
❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE
❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING
❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING
❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT
❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT
❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
$OTHER (Describe) Foundation Stabilization
(For ALL projects, please provide a detailed description of work to be performed, including current use of areas,
proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and
amount of materials to be used, etc.)
4 helical piers and 5 carbon fiber strips
Sq. Ft./LF Btu's
Amps
Squares
Gallons
Other
Project Value: (Contract value or the cost of all materials and labor included in the entire project)
$ 9,810
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any pennit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the
truthfulness of the information provided on the application.
CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)
Signature (first and last name): 1514i x�.e' DATE: 10/22/2019
DEPARTMENT USE ONLY
ZONING COMMMENTS: OCCUPANCY CLASSIFICATION:
Reviewer
BUILDING DEPARTMENT COMMENTS:
Reviewer: a4
Building Division Valuation: $ ( ��
10/22/2019
RE: Job# 2019-6856
3292 Simms St.
Wheat Ridge, CO 80033
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.dlengineer.com
As requested, a site visit and observation were performed at the property located at the address
above on 10/8/2019 at approximately 2:00 p.m. by Kelly Hoiness, PE. The purpose for the site
visit and observation was to review the structure for movement of the front porch foundation.
The subject property is a single-family home with a basement located in an established
neighborhood. The building is assumed to be built in 1967 (based on an online search of the
Jefferson County Assessors records).
The foundation is constructed of concrete and is assumed to be on spread footings. The house
appears to be constructed of wood with brick veneer. The observation was visual and limited to
the exterior of the house. No observation was performed on the roof structure or interior. For
purposes of this report we assume that the house faces west.
Observations
• Crack/damage to the foundation concrete at the northeast corner. This is likely shearing
of the concrete corner and not a structural concern.
• Settling of the front porch away from the house
• Cracks in the front porch brick
• Cracking of and settling of the driveway slab
• Separation between trim and brick veneer on south side of the garage door
• Cracks in the brick veneer near the southwest corner of the garage
• Cracks in the brick veneer on the east wall of the garage and house
• Separation between door trim and brick veneer on the east wall of the garage
Commentary
At the time of the observation, there were multiple areas of concern. It appears the front porch
has settled away from the house. This is indicated by the slope of the porch and the cracks in
the porch brick. It appears that the south wall of the house has also experienced differential
vertical movement. This movement is indicated by the separation around the garage door trim,
as well as the brick veneer cracks on the east and west walls toward the south end of the house.
The below recommendations will help prioritize items by severity.
r city 1
Wheat Ridge
itpcommQn*tiori's
Tlhe- cracks pbrved were likely caused by vertical movement of the foundation. These
movements are `most likely caused by contraction and expansion of the soil due to changing
" moisture c6ntent. The solution is to drain water away from the house and prevent it from
infiltrating the soil next to the foundation. The following is a prioritized list of recommended
repairs that should be made to stabilize the foundation:
• Install (3) new helical piers under the front porch to help mitigate vertical movement.
Continuous steel angle should be installed between the piers.
• Monitor the south wall of the garage for further signs of vertical movement. These signs
might include new or worsening cracks in the brick veneer, cracks in the foundation,
increased separation at door frame locations, and/or doors that become difficult to
operate. If further signs of vertical movement are observed, the homeowner should
contact DL Engineering for further assessment.
• Patch and monitor any cracks in concrete, brick veneer, and drywall. This will give a
baseline for any new movement. If new movement is observed, contact DL Engineering
Inc. for further assessment.
Best Practices for Foundation Maintenance
The following best practices are actions to maintain the service life of the foundation that can be
applied to all structures. Proper site drainage and placement of vegetation alone may not prevent
movement of a structure; however, they are prudent steps to avoid the contraction and expansion
of the soil due to changing moisture content. As such we share the following information, which
is not property specific, with all our clients.
Site Drainage
• The moisture around foundation elements must be controlled for the useful life
of the building. Lack of proper drainage is often a contributing factor to
foundation damage observed. The site drainage around the structure must be
maintained such that precipitations will quickly drain away. The use of proper
slope slabs -on -grade, moisture barriers, swales, and surface/subsurface drainage
systems are strongly recommended. Extensions should be attached to properly
functioning downspouts and roof drains such that they discharge a minimum of
10 feet away from the structure.
2
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC.
720-440-9450
www.dlengineer.com
itpcommQn*tiori's
Tlhe- cracks pbrved were likely caused by vertical movement of the foundation. These
movements are `most likely caused by contraction and expansion of the soil due to changing
" moisture c6ntent. The solution is to drain water away from the house and prevent it from
infiltrating the soil next to the foundation. The following is a prioritized list of recommended
repairs that should be made to stabilize the foundation:
• Install (3) new helical piers under the front porch to help mitigate vertical movement.
Continuous steel angle should be installed between the piers.
• Monitor the south wall of the garage for further signs of vertical movement. These signs
might include new or worsening cracks in the brick veneer, cracks in the foundation,
increased separation at door frame locations, and/or doors that become difficult to
operate. If further signs of vertical movement are observed, the homeowner should
contact DL Engineering for further assessment.
• Patch and monitor any cracks in concrete, brick veneer, and drywall. This will give a
baseline for any new movement. If new movement is observed, contact DL Engineering
Inc. for further assessment.
Best Practices for Foundation Maintenance
The following best practices are actions to maintain the service life of the foundation that can be
applied to all structures. Proper site drainage and placement of vegetation alone may not prevent
movement of a structure; however, they are prudent steps to avoid the contraction and expansion
of the soil due to changing moisture content. As such we share the following information, which
is not property specific, with all our clients.
Site Drainage
• The moisture around foundation elements must be controlled for the useful life
of the building. Lack of proper drainage is often a contributing factor to
foundation damage observed. The site drainage around the structure must be
maintained such that precipitations will quickly drain away. The use of proper
slope slabs -on -grade, moisture barriers, swales, and surface/subsurface drainage
systems are strongly recommended. Extensions should be attached to properly
functioning downspouts and roof drains such that they discharge a minimum of
10 feet away from the structure.
2
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.dlengineer.com
Site Vegetation
• The vegetation around the perimeter of the structure can eventually lead to
foundation movements. Vegetation can hold moisture in soil and create
excessive pressure on the foundation system. In order to reduce the risk, bushes,
shrubs, and trees should be carefully removed by an experienced
professional. Care should be taken to not further disturb or damage the existing
foundation system.
• Planters and other surface features which could retain water should be
eliminated and properly graded to reduce the possibility of moisture infiltrating
around the foundation.
Figure 1: Crack/damage to the foundation concrete at the northeast corner. This is likely shearing of the concrete
corner and not a structural concern.
W ,
tuarKsc s.. 9100 W Jewell Ave
IEa' Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
F1 I
Figure 2: Cracks in the front porch brick
Figure 3: Cracks in the front porch brick
4
Figure 4: Crocks in the front porch brick
Figure 5: Settling of the front porch away from the house
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC.
720-440-9450
www.diengineer.com
Figure 4: Crocks in the front porch brick
Figure 5: Settling of the front porch away from the house
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.dlengineer.com
Figure 6: Settling of the front porch away from the house
Figure 7: Cracking of and settling of the driveway slab
6
Figure 8: Separation between trim and brick veneer on south side of the garage door
Figure 9: Separation between trim and brick veneer on south side of the garage door
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC.
720-440-9450
www.dlengineer.com
Figure 8: Separation between trim and brick veneer on south side of the garage door
Figure 9: Separation between trim and brick veneer on south side of the garage door
'tri ' 9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.dlengineer.com
Figure 10: Cracks in the brick veneer near the southwest corner of the garage
9UOo s��O�� i1�3=
Figure 11: Cracks in the brick veneer near the southwest corner of the garage
8
'+07
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC.
720-440-9450
www.dlengineer.com
Figure 12: West wall of house and garage
Figure 13: South wall of garage
CEJ' of
Whaa9Ricf
Figure 14: Cracking of and settling of the sidewalk slab
Figure 15: Cracks in the brick veneer on the east wall of the garage
10
9100 W Jewell Ave
Lakewood, CO 80232
CIL ENGINEERING, INC.
720-440-9450
www.dlengineer.com
Figure 14: Cracking of and settling of the sidewalk slab
Figure 15: Cracks in the brick veneer on the east wall of the garage
10
do
9100 W Jewell Ave
�
Lakewood, CO 80232
OL ENGINEERING, INC.
720-440-9450
www.diengineer.com
mimic HIS
Figure 16: Cracks in the brick veneer on the east wall of the garage
Figure 17: Cracks in the brick veneer on the east wall of the garage
Cly of
�h�at �'dQe
9100 W Jewell Ave
.. Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.dlengineer.com
Figure 18: Separation between door trim and brick veneer on the east wall of the garage
IMP
Figure 19: Cracks in the brick veneer on the east wall of the house
12
r
..� •... - .. +�•:� - �.� ^ .-. 1!�
- ..-meq E
R�
,, •E�j►* . � Lir ,,.
.�iy�vYj� �
y�,•.n.,. r.
�O 1 ft17—
• /: Cracks in the brick veneer on east
wall of the house
II^
tt
�
KR
R1F
110 / 0 E 1201"9
4C
9100 W Jewell Ave
Lakewood, CO 80232
CIL ENGINEERING, INC. 720-440-9450
www.diengineer.com
In as much as the site review of an existing structure for the purpose of observing the structure
conditions requires that certain assumptions be made regarding existing conditions and because
some of these assumptions may not be verifiable without expending additional sums of money or
destroying otherwise adequate or serviceable portions of the building, the Client agrees that,
except for negligence on the part of the Engineer, the Client will hold harmless, indemnify and
defend Engineer from and against any and all claims arising out of the professional services we
have provided.
If you should have any further questions, please feel free to contact me at (720) 440-9450 or
khoiness@dlengineer.com -..,.CTTTV„_
Sincerely,
Kelly Hoiness, PE
901POSS" 1' N�4;(,
0054409 }
�s`r�ONAL EAG`
EXP. 10/31/21
14
INDEX:
S1-1 GENERAL NOTES
S1-2 GENERAL NOTES/LEGEND
S2-1 FOUNDATION PLAN
S3-1 TYP. HELICAL PIER DETAIL
S4-1 SITE PLAN
BUILDER INFORMATION:
Complete Basement Systems of CO
11795 East 45th Ave
Denver, CO 80239
1-303-219-7646
General Notes:
1. Construction documents are valid for a single use at the project location and shall not be reused, copied, or
reproduced without written approval of the registered design professional in reasonable charge.
2. The contractor is responsible for the methods, means and sequence of all structural erection except when
specifically noted otherwise in the construction documents. The contractor shall provide temporary shoring and bracing,
providing adequate vertical and lateral support during erection. Shoring and bracing shall remain in place until all
permanent members are placed and all final connections are completed.
3. The contractor agrees that, in accordance with generally accepted construction practices, the contractor will be
required to assume sole and complete responsibility for job site conditions during the course of construction of the
project, including safety of all persons and property. This requirement shall be made to apply continuously and not be
limited to normal working hours. The contractor further agrees to defend, indemnify and hold owner and engineer
harmless from any and all liability, real or alleged, in connection with the performance of work on this project, exempting
liability arising from the sole negligence of engineer.
4. All existing sizes, dimensions and foundation damage shall be field verified by the contractor and owner prior to
construction. Discrepancies with the construction documents shall be reported to the structural engineer for additional
recommendations (if any).
5. Per the owner's request, the contractor shall stabilize the structure only. No attempt shall be made to lift or plumb
the foundation wall without approval for the owner and structural engineer.
Field Verification:
1. Contractor and Owner shall thoroughly inspect and survey existing structure to verify dimensions, elevations,
framing, etc. which affect the work shown on the drawings.
2. Report any variation or discrepancies to the structural engineer before work proceeding.
Foundation Design:
1. Soil conditions and types shall be verified by a Engineer during excavation.
2. All helical piles, push piers, helical anchor tiebacks, wall anchor tiebacks and connection hardware shall be
designed and installed by supplier, such that they provide the minimum allowable capacities as indicated on the
drawings. All capacities shown on the drawings are unfactored service loads and have not been reduced for live load
reductions.
3. Design of individual and continuous footings is based on a maximum allowable bearing pressure of 1500 lbs, per
square foot (dead load plus full live load), placed on the natural undisturbed soil, or compacted structural fill below frost
depth.
Design Criteria:
1. Building code: 2012 IBC, 2012 IRC with City of Wheat Ridge Amendments
2.
Dead loads
2.1.
2.2.
Roof 15psf
Floor 12psf
- City of
"WhCal �ge
�
COMMUNI TY DEVEL0 �Pr,4N r
2.3.
Walls 10psf
3.
Live loads
APPROVED
3.1.
Residential40psf
3.2.
Roof 20psf
Reviews d for Code Compliance
4.
4.1.
Snow loads
Ground snow load 30 psf
/
5.
Wind loads
PlanExa Iner Date
5.1
Exposure Category C
VWWkyofpernlll:Theistmoveofop~orapprovalo/ptansSperppwnons
5.2
105 mph 3 -Second Gust Wind Speed
and aompu umm shah not be a permit for, or an approval ^1' ,iny mlobon to
mry of Me prov/sions of the building code or of a* City ardtAuncet AnmHs
pvesutrnnp to vw a thomy to wow& or cancel the pvevn om at Vw &sra v
coda or older ordlnorowt of theChy shoo not be m"
STEEL HELICAL PIERS:
1. Grip Tlte: Model GTRDS2875-0203 (round shaft) Helical Pier with FP3BA Retrofit Bracket
2. Install with Pro -Dig X9 torque head to 5,555 ft -lbs torque.
3.. flier depth is dependent on depth of bearing soil adequate to provide the specified torque resistance, therefore,
depth is not specified. Pier to be advanced until torque is attained.
4. Installation torque serves as empirical verifications of pier capacity, yielding an onsite load test for each pier.
Therefore, soils testing is not necessary for generating a theoretical capacity.
5. fliers shall be 8" minimum helical piers, installed at locations shown on the plans.
6. It is assumed the each new pier will achieve penetration into bedrock or competent soil, and can be installed to the
specified capacity. Should bedrock or competent soil not be reached within reasonable depth this office should be
notified for further instructions.
6. vontractor is to maintain accurate pier depth and pressure / torque charts for each pier, showing depth and
pressure / torque at each shaft section. Charts shall be filled out in real time during installation, and maintained onsite for
engineer review during inspection. Charts shall be provided to engineer in final form upon completion.
Cast -in -Place Concrete
1. All concrete design is based on the "Building Code requirements for Reinforced Concrete" (ACI 318-05/318R-05)
All structural concrete shall have a minimum 28 -day compressive strength as follows.-
1.1
ollows:1.1 Footings:3,000psi
1.2 Slab on Grade: 3,500psi
1.3 Foundation walls: 3,000psi
2. Concrete shall be placed on proportioned utilizing Type 1 cement except, concrete exposed directly to soil shall
use Type 2 cement. Concrete susceptible to freeze shall be formulated or maximum frost resistance in accordance with
the ACI
manual of Concrete Practice.
3. Cold weather and or hot weather placing procedures shall be provided, if conditions warrant, as recommended in
the A:,I manual of Concrete practice.
Reinf3rcing Steel:
1. All detailing, fabrication, and placement of reinforcing steel shall be in accordance with the ACI Manual of Concrete
Practice.
2. Reinforcing bars shall conform to ASTM A615-79 and shall be grade 60.
3. Except as noted on the drawings, minimum concrete protection for reinforcing shall be in accordance with ACI
318-05/318R-05.
4. No. 5 or larger reinforcing bars shall not be re-bent.
5. Welding of rebar is not permitted unless procedure is approved by the Structural Engineer.
Structural Steel:
1. Structural Steel shall be detailed, fabricated and erected in accordance with 2010 AISC Specification for Structural
Steel Buildings, and "Code of Standard Practices" 2005.
2. Structural Steel shall be confirmed to the following grades:
2.1 W- & WT- Shapes: ASTM A36, A992
2.2 Plates & Angles: A36
2.3 HSS: ASTM A500 gr B
2.4 Steel Pipe: ASTM A53 gr B
3. All bolts shall conform to the ASTM A325 except anchor bolts which shall conform to �PpO L/C
ASTM A307. Bolt Size shall be'/4", unless noted otherwise on the drawings.
All welding shall be by a certified welder in accordance with ACIS and AWS specifications
and recommendation. SIO SS
0054409
Cr
a„ k�EXP,
s/ONAL �; ol
� 10/31/21
REVISIONS
DATE
0
71
N
U) N
W C
Z31V0
J
� J
W
Z
W A9
0 NAHO
T`-I
As
Z
O M
0
N W
V)0,�
my��
W 0:
U) to a 19W
Z N Z
Q M W O
Z 3:
O
W
N 2
V W M O
Z > N V
IU
Z J O a W
CDZ
Z -) O 4 Z
.0 LU
Z;3Io
W 0
2019-6856
SHEET
S1-1
OF
5
Structural Wood framing:
1. Except where noted otherwise, all 2" members shall be Hem -Fir No. 2 and better.
2. Except as noted otherwise, minimum nailing shall be provided as specified in Table No 2304.9.1 "Fastening
Schedule" of the IBC. All nails shall be common type, unless noted otherwise.
3. Unless noted otherwise, steel connectors such as those manufactured by Simpson Company, shall be used to join
rafters, trusses, joists, or beams to other members at flush -framed conditions. Use maximum number and size of nails
indicated in manufactures tables U.N.O. all nails holes shall be filled.
4. All multiple members shall be glued & nailed together.
5. All wood in contact with concrete or exposed to weather, shall be pressure treated Douglas Fir -Larch No. 2 or
equal.
Structural members shall not be cut for pipes, etc. Unless specifically noted or detailed.
Periodic surveys:
1. Periodic surveys of the supported structures should be conducted to assure project success. The Owner should
be responsible for annual surveys certifying project success. We would suggest that a
baseline survey be conducted immediately. The owner shall submit all findings and
reports to the Structural Engineer.
2. If vertical movement of the piers is discovered, the piers should be
re -pressured. A representative of the Geotechnical Engineer should be present to
observe the re -pressuring. A final report should be provided by the Geotechnical
Engineer after observing the re -pressuring.
Foundation Stabilization:
1. Although observed foundation damage typically does not pose an immediate
health and hazard risk, delaying mitigation will likely make future repairs more difficult
and costly. Furthermore, it has been our experience that once a structure begins moving, it will likely continue to so
(unless action is taken) resulting in further settling,
heaving, unsightly cracks, doors/widows not functioning properly and possible foundation wall collapse. The extent and
aggressiveness of the foundation repairs should be carefully considered by the Owner and will depend on their tolerance
for risk, the possibility of future damage, and cost.
1. If the owner chooses to do so the foundation could be stabilized only at visibly damaged locations and areas
where movement is concentrated. Although this will address specific situations, it is possible that foundation movements
will occur
elsewhere.
2. If the Owner chooses to do so, the entire foundation could be mitigated. A general system repair, although more
costly, would greatly reduce the risk of future foundation damage and movement. It is our understanding that the Owner
would not
like to pursue this repair option.
Site Drainage
1. We believe that the moisture around foundation elements must be controlled for the useful life of the building.
Lack of proper drainage is often a contributing factor to foundation damage observed. It is our opinion that site drainage
around the
structure must be maintained such that precipitations will quickly drain away. The use of proper slope slabs -on -grade,
moisture barriers, swales and surface/subsurface drainage systems are strongly recommended. Extension should be
attached to
properly function downspouts and roof drains discharge a minimum of 10 feet away from the structure.
Site vegetation
1. We believe that vegetation around the perimeter of structures can eventually lead to foundation movements.
Vegetation can hold moisture in soil and create excessive pressure on the foundation system. In order to reduce the risk,
bushes, shrubs and
trees should be carefully removed by an experienced professional. Care should be taken to not further disturb or
damage the existing foundation system.
2. Planters and other surface features which could retain water should be eliminated and properly graded to reduce
the possibility of moisture infiltrating around the foundation. Irrigation systems and excessive moisture adjacent to
structures can introduce unwanted moisture, possibly resulting in settling and or heaving. The Owner should consider
removing irrigation
systems or simply not use them.
Disclaimer:
1. In as much as the site review of an existing structure for the purpose of observing the structure conditions requires
that certain assumptions be made regarding existing conditions and because some of these assumptions may not be
verifiable without expending additional sums of money or destroying otherwise adequate or serviceable portions of the
building, the Client agrees that , except for negligence on the part of the Engineer, the Client will hold harmless,
indemnify and defend Engineer from and against any and all claims arising out of the professional services we have
provided.
LEGEND:
(E) EXISTING
(N) NEW
�— PUSH PIER
P.P. #X PIER #
xxxx#
( ) LOAD ON PIER
WALL ANCHOR
W.A. #x ANCHOR #
MONO POST
M. P. #x POST #
xxxx#
( ) LOAD ON PIER
HELICAL PIER
PIER #
H. P. #x
(xxxx#) � LOAD ON PIER
REVISIONS
DATE
as
N
U) N_
W
Q 0 31Va
Z
J W
0� W
W J
Z
W A9
V' x03HO
Z
xe.
Z M
O eh
F, o
N ~ LU
Lu
NOJ
a W 0:
WOO
lu
ZNrxZ
00)
QMWO
Z 3
7
O
U.
4j Ld N2
Z_ > N U
Q 0
ZJO.4W
2LU0cpZ
ZWp-JZ
O 0 J
Z;3tio
W Z
JOB NO.
2019-6856
SHEET
S7-2
OF
5
co
1
(N) H.P. #2 S3-1
(9.0 k)
o�
co
(N) H.P. #1 '
FRONT OF (9.0 k)
HOUSE
L6x8x7/16 STEEL ANGLE.
CONTINUOUS BETWEEN PIERS
FOUNDATION PLAN
--
H.P. #3
FRONTPORCH
HOUSE/
BASEMENT
GARAGE/
SLAB
NOTES: v
1. SEE SHEETS S1-1 THROUGH SI -2 FOR GENERAL NOTES.
2. INSTALL HELICAL PIERS AND STEEL ANGLES PER PLAN.
3. SEE SHEET S4-1 FOR SITE PLAN.
REVISIONS
DATE
H
Q
N 2
ui mo
z>N u
Q0aci
Z J O g W
rgW V m Z
Z W O g W
O O J
Z;3nc
W O
L �1 Jr KO O Digi�aAy s(oi d lyE Hane
DN _Nz
O=DL Cng g,
E-khol e @
(, •V� Reason'. h this
n A L—tso nttt�����,
I' 1 J J I (aeon cP . JOB NO.
UVo,,4@a 9-1 O-321025
2019-6 6
-p�
01. ��!/Sks
EG\ S16' `S/ONAUXP. 10/31/21
FIELD VERIFY
T.O. (E) FOOTING
L6x8x7/16 CONTINUOUS STEEL ANGLE
OVERLAP AT CORNER AND GROUT TO
FOUNDATION
U
W
n.
Z_
(N) HELICAL PIER w
W_
GRIP TITE: MODEL GTRDS2875-0203 W/ FP3BA
RETROFIT BRACKET
INSTALL W/ PRO -DIG X9 TORQUE HEAD TO
5,555 FT -LBS TORQUE_
0 TYP. HELICAL PIER DETAIL
1" = V-0"
0.
U
0
H
a
w
0
REVISIONS
DATE
N 2
U w M O
Z > ca U
lz
Q p O
Z J O v W
FeWt»Z
ZW0 Z
OoJ
z;3tio
ss W O Z
QOD L/C 12
Hffi,�' p.b :oisaau 1% Q
k N .
3
JOB NO.
0054409
PORCH
2019-6856
SHEET
J
�
S3-1
r
EXP. 10/31/21
r
5
N
N
W
p
O
T
W
31VO
d
Q
J
U
�
W
A8
=
NO3K
BRACKET
CL
=
xa
H
Q
N 2
U w M O
Z > ca U
lz
Q p O
Z J O v W
FeWt»Z
ZW0 Z
OoJ
z;3tio
ss W O Z
QOD L/C 12
Hffi,�' p.b :oisaau 1% Q
k N .
JOB NO.
0054409
2019-6856
SHEET
X0,0'. '\��/�
�SS�ONAI EAG
S3-1
r
EXP. 10/31/21
of
5
PROPERTY LINE
NOTE:
1. THE EXISTING PROPERTY LINES AND EXISTING
HOUSE LOCATION ARE SHOWN AS DRAWN ON
THE ILC BY R.E.PORT LAND SURVEYING, JOB #
92-5871. DATED 10/15/2019
SITE PLAN
1/20" = 1'-0"
0..
REVISIONS
DATE
w
Z
F -
a
J
Z
O O
_.._ 29'-4" ----- 26'-5"
qH
W
�1~0W
J H V p
Z
09
yyOW
J
Z N CC Z
QMWO
HOUSE/
zz 3
w
M BASEMENT
C
O
1
aY
FRONT OF
Lo
D_
HOUSE
it
C? GARAGE/
SLAB
I�
LL-
t�
�- 24'-1" -�—
- -
�_
PROPERTY
LINE
NOTE:
1. THE EXISTING PROPERTY LINES AND EXISTING
HOUSE LOCATION ARE SHOWN AS DRAWN ON
THE ILC BY R.E.PORT LAND SURVEYING, JOB #
92-5871. DATED 10/15/2019
SITE PLAN
1/20" = 1'-0"
0..
REVISIONS
DATE
w
Z
F -
a
J
Z
O O
LLI
qH
O
a
�1~0W
J H V p
mWO'
09
yyOW
Z N CC Z
QMWO
zz 3
0
O
U.
20'
(s uiN E
Z_>Nti
190002
ZJO'TW
2 L 0z
13
Zn01
C J
Z;;n
WC
OZ
E Ibneaa Q
cn
kRC415.0.0.
Reaaon:l�m W-ryd���'gin..,.c
661
V,q$
•Y N:
0054409
/ONAt �
{P. 10/31/21
2019 Sig
S ET
5
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234=5933 Inspection line y
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number: QD ► Q Lt -4 v
i l___ }j I 1� 2c -J ^)G I jv
❑ No one available for inspection: Time KMVPM
Re -Inspection required: <�*b li�o
When corrections have been made, call for re -inspection at 303-234-5933
Date:_,>i2 Inspector:
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge
Residential Roofing PERMIT - 201704406
PERMIT NO: 201704406 ISSUED: 07/19/2017
JOB ADDRESS: 3292 Simms ST EXPIRES: 07/19/2018
JOB DESCRIPTION: Residential Re -roof to install Owen Corning asphalt shingles with 25 sq
*** CONTACTS ***
OWNER (303)345-7918 SHIEH THERESA
SUB (303)778-8010 Scott Lawerance
019349 AquaDuct Roof & Gutters
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 12,848.19
FEES
Total Valuation 0.00
Use Tax 269.81
Permit Fee 251.85
** TOTAL ** 521.66
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are
required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and
water shield is required. Eave and rake metal is required. A ladder extending 3 feet above
the roof eave and secured in place is required to be provided for all roof inspections.
Roof ventilation is required to comply with applicable codes and/or manufacturer
installation instructions, whichever is more stringent. In order to pass a final inspection
of elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer technical representative stating that "the application of the roof at (project
address) has been applied in accordance with the installation instruction for (roof
material brand name) roof covering" is required to be on site at the time of final
inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
City of Wheat Ridge
Residential Roofing PERMIT - 201704406
PERMIT NO: 201704406 ISSUED: 07/19/2017
JOB ADDRESS: 3292 Simms ST EXPIRES: 07/19/2018
JOB DESCRIPTION: Residential Re -roof to install Owen Corning asphalt shingles with 25 sq
I, by my signa re,{do hi"�reby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable W ding codand all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by th legal nor of throperty and am authorized to obtain this permit and perform the work described and approved in conjunction with
thisermit. f er at st that I am legally authorized to include all entities named within this document as parties to the work to be
per med n a or to be perforn4ed is disclosed in this document and/or its' accompanying approved plans and specifications.
7- Z/7, 1
Signattire of' OWNER C&TRAC-`O (Circle one) Date
1, This permit was issued`6 ased-apt ormation provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official %1-_,J Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
(*-7
Dan Schultz Kj� � 1
From:
no- reply@ci.wh eatridge.co.us
Sent:
Tuesday, July 11, 2017 10:15 AM
To:
Permits CommDev
Subject:
Online Form Submittal: Residential Roofing Permit Application
Categories: Gina
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address 3292 Simms Street Wheat Ridge, CO 80033
Property Owner Name Theresa Shieh
Property Owner Phone 303-345-7918
Number
Property Owner Email theresashieh@hotmail.com
Address ,_, a � t (;
Do you have a signed Yes
contract to reroof this
property?
It will need to be
provided at the time of
permit pick-up.
CONTRACTOR INFORMATION
Contractor Name
Contractor's License
Number (for the City of
Wheat Ridge)
Contractor Phone
Number
Aquaduct Roof & Gutters
01-9349
303-778-7663
Contractor Email Address quotes@aquaductgutters.com
Retype Contractor Email quotes@aguaductgutters.com
Address
DESCRIPTION OF WORK
Are you re -decking the
roof?
Description of Roofing
Material
Select Type of Material
If "Other" is selected
above, describe here:
No
Owen Corning
Asphalt
Field not completed.
How many squares of the 25
material selected above?
Does any portion of the No
property include a flat
roof?
If yes, how many squares 25
on the flat roof?
TOTAL SQUARES of all 25
roofing material for this
project
Provide additional detail Re -roofing
here on the description of
2
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
Project Value (contract 12,848.19
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant Scott Lawrence
Email not displaying correctly? View it in your browser.
3
Bid generated for Theresa Shleh
Company Receipt Page
Owens Corning
Oakridge LLT
8rownwood
110 mph wind resistance warranty
UL Class A Fire Rating
Tough FiberglasO mat core
Limited Lifetime warranty, 10 year Tru
PROtection@ Coverage
Weathering grade asphalt
Owens Corning
Oakridqe LLT
Total Cost: $ 12,848.19 ,
8rownwood
Custom bid generated for
Theresa Shieh
3292 Simms Street
Wheat Ridge, Colorado 80033
303-345-7918
Job site address
3292 Simms Street
Wheat Ridge, Colorado 80033
303-345-7918
Product Choice: 0 , C A
Color Choice:
Authorized Signature: Customer Signature:
Date: 7 .z 7 Date 1-7
Cc 1 C -oz-,- �`5 ea
AquaDuct Roof & Gutters
-
§
@
H
2
!
`
o
«
�
G\/
\H3R
2
my;OC, �
%
65\\
/
aQ�w \
!
k
�
/
\
\
«
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: ',�
Job Address: �. `
Permit Number:
❑ No one available for inspection: Time ,E ` ` A/P ,
Re -Inspection required: Yes 1Vo
When corrections have been made, call for re -inspection at 303 -234 -
Date:
03-234-Date:''a ` Inspector: �f7
DO NOT REMOVE THIS NOTICE
♦ i CITY OF WHEAT RIDGE
Bung Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: Kt''r
Job Address: h9 ~,^inht c, ~f
Permit Number: C ' 37, V /y
/Glu~ mp Ls ~/ur~Q. !w
❑ No one available for inspection: Time P P AM
Re-Inspection required: Yes No
When corrections have been made, call for re-inspection at 303-234-5933
Date: O Inspector: t)v , f/ f%1
DO NOT REMOVE THIS NOTICE
♦ i CITY OF WHEAT RIDGE
Building Inspection Division
r' (303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:'( Jff o
Job Address:
Permit Number:
~0/K
❑ No one available for inspection:: Time f A /PM
Re-Inspection required: Yes TV
When corrections have been made, call for re-inspection at 303t 303• 234-5983
Date: Inspector: c
DO NOT REMOVE THIS NOTICE
" 1 City of Wheat Ridge
Residential Roofing PERMIT - 093401
PERMIT NO: `093401 S. ISSUED:. 10/15/2009
JOB ADDRESS:. 3292 SIMMS ST 'EXPIRES: 04/13/2010
DESCRIPTION:< Reroof 24 sqs
CONTACTS
owner 303/955-2882 Pruyn
sub 303/778-8010 Scott Lawerance 01-9349 AquaDuct Roof & Gutters
**:PARCEL INFO
ZONE CODE: UA USE: UA
SUBDIVISION:: 0659. -.BLOCK/LOT#: 0/.
FEE SUMMARY ESTIMATED :PROJECT 'VALUATION: 9,153.00
FEES
Permit Fee 235.70
Total valuation oo
Use Tax 164.75 i
**TOTAL 400.45
2onditions:
5 nail installation& mid-roof inspection required. Board sheathing spaced more
-hall a 1/2 of an inch apart requires plywood overlay on entire roof. Ice and
water shield` required from'eave edge to 21 inside exterior walls.
a**Contractor/Property owner shall provide -iadder.(s) secured in place for
inpsections.'
Subject field inspection.
I hereby cer ifylthat the setbac distances proposed by this permit application are accurate, and do not violate applicable
ordinanc s, lea or regulatio of the City of Wheat Ridge or covenants, easements or restrictions of record; that all
measurem nts shown, and alleg ions made are accurate; that I have read and agree to abide by all conditions printed on this
applicat on d- at assum full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other
app ab a i Ordi ances, for work under this permit. Plans subject to field inspection.
S' n t contract owner '..date
Th it was issued in accordance with the provisions set forth in your application and is subject to the laws of the
Sta of Colorado and to the zoning Regulations and Building Codes of Wheat .'Ridge, Colorado or any. other applicable
Drain noes ofrl the city.
This permit shall expire.180 days from the issue date. Requests for an extension must be received prior to expiration
date. An extension may be grantedat the discretion of the Building Official.
If this permit expires, 'a new permit may be acquired for a fee of one-half the amount normally required, provided no
changes have been or will be made in the original plans and specifications and any suspension or :abandonment has not
exceeded one ".(1) year. If changeshave been or if suspension or abandonment exceeds one (1) year'. full fees zshall
he naid fnr znPw narmi♦
Lgnature f Building Official : date
NSPEC ON REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855
EQUESTS MUST BE MADE BY 3PM ANY BUSINESS ;DAY FOR INSPECTION THE 'FOLLOWING BUSINESS DAY.:.
~oF W"E r~o City of Wheat Ridge Building Division
m 7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
°O<orxno° Inspection Line: 303-234-5933
Building Permit Application
Date:
Plan
Permit#:V 1
Property Address; m~-
Property Owner (please print): Pew Y\ Phone )qw ZaZ=
Mailing Address: (if different than property address)
Address: n , ~ „
Sub Contractors:
Electrical City License
Company:
Plumbing City License
Company
Mechanical City License
Company:
Exp. Date: Exp. Date: Exp. Date:
Approval: Approval: Approval:
Use of space (description): 7 Construction Value: $
Description of~work; p (as calculated per the Building Valuat on Data sheet)
w \ 2,4- LnY/ t MO-✓~ Plan Review due at time of submittal : y
Sq. Ft./L.Ft added: Squares z,4-~ BTU's Gallons Amps
OWNER/CONTRAC'OR SIGNATURE OF UNDERSTANDING AND AGREEMENT
1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or re rictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all con ions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (I. B. C) an 11 other applicable Wh t Ridge Ordinances, for work
under this permit. Plans subje r e, on.
CIRLCE ONE:: (OWNE (C 7RA TOR) or P 'SONAL REP NT VE o WN ) (CONTRATOR)
PRINT NAME: SIGNATU - Date~b
Contractor License Phone: 3 L)J (7(Y -7iZ3