HomeMy WebLinkAbout3902 Nelson Street♦ i , CITY OF WHEAT RIDGE , Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type:-` Job Address: !' Permit Number: ` ❑ No one available for inspection: Time I I AM/PM Re -Inspection required: Ye .-_ When corrections have been made, schedule for re -inspection online at. h ttp J/www. ci. wheatridge. co. usgnspec_tiM / k. 41 Date:Ipector.f i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOT CSE Inspection Type: Job Address: ` f PermitNumber: ---�- } i IJNo one available for inspection: Ti 'r AM/PM Re -Inspection required` Yep% No When corrections have been made, schedule fo spectton online at. http.-IAvww.ci.wheatridge.co.usViospktion Ddt = I • C�7 0 I(nspeo -' ---- 1* ► � i City of Wheat Ridge '/� Residential Solar PERMIT - 202001997 PERMIT NO: 202001997 ISSUED: 10/12/2020 JOB ADDRESS: 3902 Nelson St EXPIRES: 10/12/2021 JOB DESCRIPTION: Install solar PV system, 4.95 kw, 15 panels on house roof, structural required *** CONTACTS *** OWNER (720)448-3603 LEE JONATHAN & AMANDA CLAYTON SUB (800)467-4562 AMANDA ROSEBURG 202207 EMPIRE SOLAR GROUP, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 81663.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications, applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Solar PV Installation Date: Monday, October 5, 2020 2:28:53 PM Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes Solar PV Installation? PROPERTY INFORMATION Property Address 3902 Nelson St, Wheat Ridge, Colorado 80033 Property Owner Name Jonathan Lee & Amanda Clayton Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" (720) 448-3603 amandaclayton006@gmail.com Electronic -Payment -Form. odf CONTRACTOR INFORMATION Contractor Business Name Wheat Ridge Contractor's License Number (This is a 5 or 6 digit number for the Empire Solar Group 202207 City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) Contractor Email Address Retype Contractor Email Address DESCRIPTION OF WORK Scope of Work KW # of Panels Location of Panels Structural required Upload engineer letter or pages on 8 1/2" x 11" only Solar Installation Plan Set on 11'x17" only. Project Value (contract value or cost of ALL materials and labor) 801-609-5291 copermits@empiresolargroup.com copermits@empiresolargroup.com To install 4.95MN PV array rooftop system 4.95 15 House Roof Yes Jonathan Lee - 12812.odf Lee Jonathan Plan Set 1.0 STAMPED.Ddf 8663 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Alexa Archuleta Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. 10/2/2020 Re: Solar Installation for Jonathan Lee 3902 Nelson St, Wheat Ridge, Colorado 80033 To whom it may concern Empire Solar Group 9 Exchange Place Suite 400 Salt Lake City, UT. 84111 office (800) 467-4562 Job# 12812 I have evaluated the roof system at the above-mentioned address to determine its capacity with the addition solar panels. the following criteria were used in my analysis to determine the loading and structural capacity of existing framing. Building codes: Wind Velocity used -Vultimate-: Wind Velocity required-V.asd -: per IBC 1609.1.1 Exposure Category Roof Snow Load used: Pitch of trusses: IBC 2015, ASCE 7-10 120 (mph) 93.0 (mph) C 40 (psf) 3 /12 The existing trusses were then evaluated based on their span, pitch, depth, framing member size (2x4 DFLtrusses @24" o.c.), and attachmentto sheathing. Trusses were analyzed under the following loads. Dead load of panels at each attachment point: 24.64 lbs Snow load +Dead load per attachment point: 376.64 lbs Wind load per attachment point Interior roof zone: -386.04 lbs Edge zone at eaves: -386.04 lbs Edge zone at gable: -303.32 lbs Corner zone at ridge: -358.47 lbs Corner zone at eaves: -275.74 lbs 1. Solar panels should be mounted to rails in accordance with the most recent "Ironridge Installation Manual" which is found (http:\\ironridge.com\) At rail ends near panel array edge zones, solar panels supports should be attached attached to trusses to at each rail. At interior points, rail supports may be attached to trusses in a staggered pattern with no more than 48" between support points along a single rail. 2. Solar panels shall be attached to trusses using a 5/16" diameter lag screw. The allowable pullout per lag screw is 258 lbs/inch as identified in the NDS (National Design Standards. Penetration of the lag screw shall be a minimum of 2 1/2" inches into each truss. 3. Roof Pitch, member sizes, and geometric data for this analysis was obtained from a site survey conducted by Duncan Twyman of Empire Solar Group acting under my responsible charge. Satellite aerial imagery, and topographical site information from other sources also provided geometrical data used in this evaluation. I provide my certification as a licensed engineer registered in this state that this structure has the capacity to resist the additional loads, and the altered loading scenario induced with the attachment of this solar array. If you have any questions regarding this analysis, please do not hesitate to contact me. Very respectfully O o�pDOL O� ..N MARA 41/0/211020 r �o��ss/ONA�E�G� Stephen Mark Bryner, P.E. Empire Solar Group (D L7 .r r; o rr PARCEL MAP LEE JONATHAN 4.95 KW DC SOLAR PHOTOVOLTAIC SYSTEM 3902 NELSON STREET WHEAT RIDGE COLORADO 80033 Z � Z =_� City of W heat Ridge - � y COMMUNI"iY UEVEIOPMENT a a - 4 APPROVED Reviewed for Code Compliance 3902 Nelson Street 0.7D2D Approval Notes: Plans Examiner Date 1) P/V array system to have grounding system installed per Part III of z Article 250 per 2020 NEC Article 690.47(A). valwity0mmu: mrlaeaara a/o aermxa opprowOoJAlaas Wenla allnne m 3 2) If UFER ground in not available provide or verify supplemental uaacomPomnoossnoa weneopnmrfr o mopp.wao%ooynorononm J ° ground rods per 2020 NEC Article 250.53(A)(3). onr M the wowsi m c/ me buMM9 cone or of aW cup ammnce,. xrmna U VICINITY MAP 3)Cold&Hot Water&Natural Gas bonding per 2020 NEC Article 250.104(A)(B) ��"g Lo BM nutharlry to eroralr w wmel the pmYwans of NM.iWWaq `od""oM"an*mfi'"ftotys nobeMCA -4 OF 01 - SCOPE OF WORK; SHEET INDEX, VICINITY MAP ay INSTALLATION (15) SILFAB SLA -NL 330 02 - GOVERNING CODES, NOTES (15) SOLAREDGE P340 DC -DC OPTIMIZER 03 -PROPERTY PLAN ;� (1)SOLAREDGE SE380OH-US 04- ROOF PLAN; EQUIPMENT LOCATIONS 'r STC RATING: 4.95 KW ADDITIONAL SERVICES: 05 -ROOF FRAMING, ELEVATIONS, ATTACHMENT DETAILS _. 06 - ELECTRICAL LINE DIAGRAM - OCCUPANCY TYPE: R-3 07 - ELECTRICAL CALCULATIONS CONSTRUCTION TYPE: V -B 08 -LABELS AHJ: WHEATRIDGE 09- INTERCONNECTION PHOTOS — APN: 300048839 10 -DIRECTORY PLACARD 0. AERIAL MAP SCOPE OF WORK 11 -OPTIMIZER MAP SHEETINDEX EMPIRE SOLAR GROUP LEE JONATHAN DATE: 10/1/2020 01 + EMPIRE 6535 YORK STREET UNIT 120 3902 NELSON STREET REVISION 1: REVISION 2: 1 DENVER, CO 80299 WHEAT RIDGE COLORADO 80033 REVISION 3: S0 R G R D U PLICENSE#EC-010111 12812 39.77 DRAWN BY: DL SCOPE OF WORK ME: 1602 105.11 ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: 20181BC 20181RC 2018 NEC 2018 UMC 2018 UPC 20181FC IEEE STANDARD 929 UL STANDARD 1741 OSHA 29 CFR 1910.269 WHERE APPLICABLE, RULES OF THE PUBLIC UTILITIES COMMISSION REGARDING SAFETY AND RELIABILITY THE AUTHORITY HAVING JURISDICTION MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS ELECTRICAL EQUIPMENT SHALL BE APPROVED BY VN-IEATRIDGE GOVERNING CODES 1. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE BELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED STING LABORATORY ACCREDITED BY THE UNITED STATES ;CUPATIONAL SAFETY HEALTH ADMINISTRATION. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO [TIATING CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL MANUFACTURER STALLATION DOCUMENTS PRIOR TO INITIATING ALL EQUIPMENT AND ASSOCIATED CONNECTIONS OF VERTERS, MODULES, PV SOURCE CIRCUITS, BATTER INNECTIONS, ETC. AND ALL ASSOCIATED WIRING AND iERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED THE CONTRACTOR OR OWNER MUST PROVIDE ROOF ACCESS ADDER TO ROOF) FOR THERLL REQUIRED INSPECTIONS. DDERS MUST BE OSHA APPROVED, MINIMUM TYPE I WITH A RATING, IN GOOD CONDITION AND DESIGNED FOR ITS ENDED USE. EMPIRE SOLAR GROUP EMPIRE 6535 YORK STREET UNIT 120 DENVER, C0 80299 sow -a 6Ro�P LICENSE#EC-010111 ME: 1602 7. CONTRACTOR SHALL VERIFY THAT THE ROOF STRUCTURE WILL WITHSTAND THE ADDITIONAL LOADS. 8. LAG SCREWS SHALL PENETRATE A MINIMUM 2" INTO SOLID SAWN STRUCTURAL MEMBERS AND SHALL NOT EXCEED MANUFACTURER RECOMMENDATIONS FOR FASTENERS INTO ENGINEERED STRUCTURAL MEMBERS. 9. AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT PLACE THE GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. 10. WHERE DC CONDUCTORS ARE RUN INSIDE BUILDING, THEY SHALL BE CONTAINTED IN A METAL RACEWAY; THEY SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE COVERED BY THE PV MODULES AND EQUIPMENT. 11. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES - NO BUILDING, PLUMBING, OR MECHANICAL VENTS TO BE COVERED, OBSTRUCTED OR ROUTED AROUND SOLAR MODULES. 12. ALL FIELD -INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS. Iq�Q�l1:7(N_1� 1. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25°C AND MAXIMUM VOLTAGE AT 600V; WIRE SHALL BE WET RATED AT 90°C. 2. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE -2 OR PV TYPE WIRE. 3. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND G ROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR -CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS 4. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN -TIGHT AND APPROVED FOR USE IN WET LOCATIONS. LEE JONATHAN 3902 NELSON STREET WHEAT RIDGE COLORADO 80033 12812 39.77 ms.11 5. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. 6. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. 7. REMOVAL OF AUTILITY-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 8. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH AGROUND -FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCU RED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS. 9. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION. 10. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER GEC/EGC PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 11. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER G.E.C. VIA WEEB LUG, ILSCO GBL-4DBT LAY -IN LUG, OR EQUIVALENT LISTED LUG. 12. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT. 13. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. 14. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. 15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND LOAD". 16. WHEN APPLYING THE 120% RULE, THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER. 17. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED. DATE: 10/1/2020 O REVISION 1: REVISION 2: REVISION 3: NOTES DRAWN BY: DL NOTES NELSON STREET 117'-8" 57'-6" - A (E) SINGLE FAMILY HOME C' &offf/ 0 ORND L ............ Ns n ,O 28,-3„A 's 1 /02/2020 e (E) DRIVEWAY - o � (E) PROPERTY LINE W- A PROPERTY DETAILS N Scale. 1...12' _ 117'-8" EMPIRE SOLAR GROUP LEE JONATHAN DATE: 10/1/2020 03 EMPIRE 6535 YORK STREET UNIT 120 3902 NELSON STREET REVISION 1: REVISION 2: DENVER, CO 80299 WHEAT RIDGE COLORADO 80033 REVISION 3: So R ORoU. LICENSE#EC-010111 12812 PROPERTY PLAN 39.77 DRAWN BY: DL ME: 1602 105.11 LEGEND J 3' FIRE SETBACKS FIRE ACCESS POINT ❑ OIROOF VENTS/ OBSTRUCTIONS SERVICE POINT & UTILITY METERING I® IINVERTER (INTEGRATED DC DISCONNECT) JUNCTION BOX A1,A2,A3.... I STRING DESIGNATIONS (A1=STRING 61,62,63.... 1, B1=STRING 2, ETC) ______ ICONDUIT RUN CONDUIT TO BE RUN ON CONDUIT BLOCKS MIN. 1" ABOVE ROOF SURFACE, CLOSE TO RIDGE LINES, AND UNDER EAVES; TO BE PAINTED TO MATCH EXTERIOR/ EXISTING BACKGROUND COLOR OF ITS LOCATION; TO BE LABELED AT MAX 10' INTERVALS CONDUIT RUNS ARE APPROXIMATE AND ARE TO BE DETERMINED IN THE FIELD BY THEINSTALLERS ARRAY 1 AZIMUTH:900 PITCH: 18° SQ. FT: 259.5 qmlwlmm.m=- PLAN V s�ia r 10 DATE: 10/1/2020 EMPIRE SOLAR GROUP 04 LEE JONATHAN REVISION 1: EMPIRE 6535 YORK STREET UNIT 120 3902 NELSON STREET REVISION 2: DENVER, CO 80299 WHEAT RIDGE COLORADO 80033 REVISION 3: SOLAR GROUPLICENSE#EC-010111 12812 ROOF PLAN 39.77 DRAWN BY: DL ME: 1602 105.11 ROOF AREA 1 f RODE AREA 1- ARRAY 1 LEGEND Module (Roof Zones) Zone 1 Q Zine 2 Zone 3 SFM Components 0 SFM Microrail2" o SFM Splice 6.5" so SFM Attached cx, Splice S" al O SFM Trim Attachment SFM Trim Univ Clip �pDO Full Trim Section o`o•�NMA �• Cut Trim Section e�� �q EMPIRE SOLAR GROUP EMPIRE 6535 YORK STREET UNIT 120 DENVER, CO 80299 S0 R GROUP LICENSE#EC-010111 ME: 1602 LEEJONATHAN 3902 NELSON STREET WHEAT RIDGE COLORADO 80033 12812 39.77 105.11 DATE: 10/1/2020 O REVISION 1: REVISION 2: ws REVISION 3: ATTACHMENT DETAIL DRAWN BY: DL WIRE SECTION [A] (2) #10 AWG PV WIRE (1) #6 BARE COPPER EGC FREE AIR (2) #10 THWN-2 A String of 15 (1) #10 THWN-2 EGC ❑ MIN. 1/2" EMT Silfab SLA -NL 330W WIRE SECTION [B] SOLADECK NEMA 3R RATED P-340 DC JUNCTION BOX: OPTIMIZERS SHALL COMPLY W/ NEC 110.3 & 314.16 WIRE SECTION [C] (3) #10 THWN-2 (1) #10 THWN-2 GND MIN. 3/4" EMT Utility Interactive Inverter SolarEdge SE380OH-US-US SO LAREDGE RAPID SHUTDOWN KIT & INTEGRATED DC DISCONNECT Approval Notes: 1) PN array system to have grounding system installed per Part III of Article 250 per 2020 NEC Article 690.47(A). 2) If UFER ground in not available provide or verify supplemental ground rods per 2020 NEC Article 250.53(A)(3). 3) Cold & Hot Water & Natural Gas bonding per 2020 NEC Article 250.104(A)(B) (N) AC DISCONNECT 30A 240V NEMA 3R NON -FUSIBLE, VISIBLE LOCKABLE LABELED WIRE SECTION [C] (3) #10 THWN-2 (1) #10 THWN-2 GND MIN. 3/4" EMT UTILITY SERVICE 120/240V SINGLE PHASE (N)PV OCPD 2P 20A --------------------- -�-- -- ------ - - - - - I VISIBLE LOCKABLE LABELED DISCONNECT IS WITHIN 10' OF THE UTILITY METER (E)200A RATED MAIN SERVICE PANEL MAIN SERVICE DISCONNECT 200A/2P (E) LOADS --�FACILITY GROUND (E) GROUND ROD+ (E) WATER PIPE BOND NOTES: MODULES ARE BONDED TO RAIL USING UL 2703 RATED BONDING SYSTEM - INTEGRATED BONDING MID -CLAMPS + DIRECT -BURIAL LAY -IN -LUGS; SEE ATTACHED FOR SPECIFICATIONS -IF APPLICABLE, PV DC SYSTEM IS UNGROUNDED PV ARRAY WILL HAVE A GROUNDING ELECTRODE SYSTEM IN COMPLIANCE WITH NEC 250.58 AND 690.47(A) .PV SOURCE, OUTPUT, AND INVERTER INPUT CIRCUIT WIRING METHODS SHALL COMPLY WITH NEC 690.1(G) -BACKFED PV BREAKER WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM SIGNAGE, PA,. BARE COPPER IS TRANSITIONED TO THWN-2 VIA IRREVERSIBLE CRIMP; WHEN PRESENT, THE GEC TO BE CONTINUOUS AS PER CEC 250.64(C) -INVERTER(S) TO BE COMPLIANT WITH UL 1741 SUPPLEMENT A DATE: 10/1/2020 EMPIRE SOLAR GROUP 06 LEE JONATHAN REVISION 1: EMPIRE 6535 YORK STREET UNIT 120 3902 NELSON STREET REVISION 2: DENVER, CO 80299 WHEAT RIDGE COLORADO 80033 REVISION 3: s o U^ a O R o u P LICENSE#EC-010111 12812 1 -LINE DIAGRAM 39.77 DRAWN BY: DL ME: 1602 105.11 PV MODULE ELECTRICAL SPECS - SILFAB SOLAR SIL -330 NL POWER MAX (Pmax) 330W OPEN CIRCUIT VOLTAGE (Voc) 40.5V SHORT CIRCUIT CURRENT Qsc) 10.42A MAX. POWER -POINT VOLTAGE (Vmp) 33.3V MAX. POWER POINT CURRENT (Imp) 9.92A SERIES FUSE RATING 20A INVERTER ELECTRICAL SPECS-SOLAREDGE 3800H MAX INPUT DC VOLTAGE 480V MAX INPUT CURRENT 10.5A NOMINAL DC INPUT VOLTAGE 380V MAXIMUM OUTPUT POWER 3800W MAXIMUM CONT. OUTPUT CURRENT 16A MAXIMUM EFFICIENCY 99% VALUES AT DC -DC OPTIMIZER (SOLAREDGE P340) # OF MODULES IN SERIES PER OPTIMIZER 1 MODULE MAX. OUTPUT VOLTAGE (1 x 40.45 x g6.1A 1.14) MAXIMUM VOLTAGE OPTIMIZER MAXIMUM ALLOWABLE INPUT 48V VOLTAGE NUMBER OF MODULES IN PARALLEL PER 1 OPTIMIZER 18.8A MODULE MAX. OUTPUT CURRENT (1 x 9.96) 9.96A OPTIMIZER MAX ALLOWABLE INPUT CURRENT 15A EMPIRE SOLAR GROUP EMPIRE 6535 YORK STREET UNIT 120 DENVER, C0 80299 sow -a 6Ro�P LICENSE#EC-010111 ME: 1602 (SYSTEM CONFIGURATION (TOTAL NUMBER OF MODULES PAIRED WITH OPTIMIZERS (NUMBER OF OPTIMIZER STRINGS AT INVERTER NUMBER OF DC -DC OPTIMIZERS IN SERIES STRING 1 VALUES AT DC -DC OPTIMIZER (SOLAREDGE P340) # OF MODULES IN SERIES PER OPTIMIZER 1 MODULE MAX. OUTPUT VOLTAGE (1 x 40.45 x ,,,� 46.1A li_Cer MODULE MAX. OUTPUT CURRENT (1 x 9.96) IZER MAX ALLOWABLE INPUT CURRENTI15A VALUES AT DC DISCONNECT (SE3800H-US) NOMINAL VOLTAGE/OPERATING RANGE MAXIMUM POWER -POINT VOLTAGE 380V MAXIMUM POWER -POINT CURRENT 16.5A MAXIMUM VOLTAGE 480V SHORT CIRCUIT CURRENT 30A AC VALUES AT INVERTER NOMINAL VOLTAGE/OPERATING RANGE 240/211-264V UTILITY VOLTAGE 120/240 V CEC EFFICIENCY 99% OVERCURRENT PROTECTION 20A WIRE SIZE CALCULATIONS WIRE SECTION (REFER TO LINE [A] [B] [C] DIAGRAM) SIZE OF PV BREAKER 20A 100 + 30 <= 125 x 1.2; 130<= 150, OK MIN AMPACITY REQUIRED (OPT/INV MAX CURRENT * 1.25) 18.8A 18.8A 20A CONDUIT TYPE &SIZE FREE AIR 1/2" EMT 3/4" EMT GROUND 6BARE 10 THWN-2 10 THWN-2 COPPER EGC GND WIRE SIZE 10 AWG 10 AWG 10 AWG WIRE TYPE PV WIRE THWN-2 THWN-2 WIRE AMPACIfY AT 30°C 40A 40A 40A WIRE/CONDUIT LOCATION BEHIND MODS ATTIC EXTERIOR AM BIENT TEM PERATURE 66° 66° 39° ROOF TOP CONDUIT ADDER 0° 0° 0° (PER CEC 310.16(B)(3)(C)) 66° 66° 39° TOTAL TEMP TO DEBATE 0.76 0.65 0.91 AM BIENT TEMP CORRECTION FACTOR 1.0 1.0 1.0 MULTIPLE CONDUCTOR ADJUSTMENT 30.4 26 36.4 FACTOR (PER CEC 310.16(B)(3)(A)) LEE JONATHAN 3902 NELSON STREET WHEAT RIDGE COLORADO 80033 12812 39.77 ms.11 BUSBAR CALCS-120% RULE SIZE OF MAIN BUS 200A SIZE OF MAIN BREAKER 200A SIZE OF PV BREAKER 20A 100 + 30 <= 125 x 1.2; 130<= 150, OK DATE: 10/1 /2020 REVISION 1: REVISION 2: REVISION 3: DRAWN BY: DL C,� �a _� �,yrr, (�idec�„ �a] %�Za ELECTRICAL CALCS LABELS: ALL LETTERS SHALL BE CAPITALIZED, 3/S" WHITE LETTERING ON RED BACKGROUND, ARIAL OR SIMILAR FONT, NON -BOLD, REFLECTIVE, ON WEATHER -RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL -969 AS STANDARD FOR WEATHER RATING) WILL BE USED; DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. SIGNAGE CANNOT BE HAND WRITTEN(PER NEC 110.21) CA) TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE �B) TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE, AC DISCONNECT, AND PV LOAD CENTER WARNING DUAL POWER SUPPLY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: 20A NORMAL OPERATING VOLTAGE: 240V (C) TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE AND SUB PANELS WARNING: THIS SERVICE METER IS ALSO SERVED BY A PHOTOVOLTAIC SYSTEM (D) TO BE INSTALLED NEXT TO THE PV BREAKER AT THE MAIN ELECTRICAL SERVICE AND PV LOAD CENTER WARNING INVERTER OUTPUT CONNECTION: DO NOT RELOCATE THIS OVERCURRENT DEVICE (E) TO BE INSTALLED ON THE INVERTER ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY UNGROUNDED AND MAY BE ENERGIZED avnw�nr (F) TO BE INSTALLED ON THE DC DISCONNECT WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND THE LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION (G) TO BE INSTALLED AT THE DC DISCONNECT PER NEC 69053 PV SYSTEM DC DISCONNECT MAXIMUM VOLTAGE:480 VDC MAXIMUM CIRCUIT CURRENT:15 A MAXIMUM RATED OUTPUT CURRENT OF DC-T0.DC CONVERTER QF INSTALLED):15A (H) MusT Be aBovloeo NExT To nc olscoNNECT aEB NEc eeo seLgLa7 (I) TO BE INSTALLED AT THE AC DISCONNECT �� ) TO BE INSTALLED AT THE JUNCTION BOXES AND DC DISCONNECT (UNDER GROUNDED SYSTEMS) WARNING ELECTRICAL SHOCK HAZARD THE DC CONNECTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED IN THE OPEN POSITION (K) TO BE PLACED AT JUNCTION BOXES, DISCONNECTS, RACEWAVS, ENCLOSURES AND CABLE ASSEMBLIES, MARKINGS SHALL BE PLACES ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAVS, ENCLOSURES, AND CABLE ASSEMBLIES EVERV 10 FEET, WITHIN 1 FOOT OF TURNS OR BENS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/ CEILING ASSEMBLIES, WALLS OR BARRIERS (L) TO BE INSTALLED AT THE DEDICATED LOAD CENTER PV LOADS ONLY - DO NOT ADD ADDITIONAL LOADS (N) PROPERTY SPECIFIC DIRECTORY PLACARD TO BE INSTALLED AT MAIN ELECTRICAL SERVICE, PLEASE SEE PG 8 FOR MORE DETAILS (0) TO BE INSTALLED AT MAIN ELECTRIC SERVICE THIS ExncT slcN Is BEouIBEo oN THE oulsloE LOB Lmlrvw a' oF7 THe SF2/ICG P/W FI R(ll�RO PFR NFC F905FlCl(il � SOLAR PV SYSTEM IS EQUIPPED VV1TH RAPID SHUTDOWN: � POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY METER MAIN AC DISCONNECT PV METER SUB PANEL duNcnoN Box oc ols�NNECT wvEBrEB (vuiEN aBESENn (uvrvEN aBESBVT7 �Bv aBESENT7 F. (E) (B)(C) (A)(B) �,_ �� J , , CC) CF)CG)P) _ D)(�"�)(O ,. CK) (D) EMPIRE SOLAR GROUP EMPIRE 6535 YORK STREET UNIT 120 DENVER, C0 80299 sow -a 6Ro�P LICENSE#EC-010111 ME: 1602 LEE JONATHAN 3902 NELSON STREET WHEAT RIDGE COLORADO 80033 12812 39.77 ms.11 DATE: 10/1 /2020 REVISION 1: REVISION 2: REVISION 3: DRAWN BY: DL LABELS PV PLACARD AND SIGNAGE O DO NOT RELOCATE �Nttt THIS OVERCURRENT NEC 69EAW) 6 NEC MSI DEVICE ELECTRIC SHOCK HAZARD MURMURS SIR YTERMINALS NEC 70512(N(S ON THE LINEAND ND LOAD SIDES MAY BE ENERGIZED TEM s _.... IN THE OPEN POSITION e,. NEC 70512(BN3) WC6901W) BNEC705 R LOCATED ATTHE POINT OF INTERCONNECTION FOR LOCATED ATALLPV DISCONNECTING MEANS WHERE EQUIPMENT WMAINING OVERCURRENT DEVICES IN OR OA BUSNARCE AIL TERMINALS OF THE DISCONNECTING MEANS MAY BE SUPPLIELYINGD CONDUCIRCUICTOR MOMMULOWER CANDIILTOI9UPPLIEO FROM MULTIPLE SOURCES ENERGIZED N TIE OPEN POSITION LOCATED AT EACH SERVICE EON IPMENT AND ALL ELECTRIC POWER PRODUCTION SOURCE LOCATIONS LWARNIN ® DO NOT RELOCATE THIS OVERCURRENT NEC 69EAW) 6 NEC MSI DEVICE LOCATED AT THE FOM OF INTERCONNECTION AND MURMURS SIR MARKEDATALLP.0 OISCONNECTMO MEANS NEC 70512(N(S LOCATED AT THE PONT OF INTERCONNECTION AND MARKED AT ALL AC DISCONNECTING MEANS EMPIRE EMPIRE SOLAR GROUP 6535 YORK STREET UNIT 120 DENVER, CO 80299 LICENSE#EC-010111 ME: 1602 NEC DA 3¶0X3 A a) LOCATED ON EXPOSED RACEWAYS, CPBIE THAWS, crnERSANO CHTERURINOFEUIDDS eoxEs, u)o O1HER WIRING MEllg03 LABEL SHALL BE SPACED AT MAXIMUM 18 IT SECTION: OR WHERE SEPARATED BY ENCLOSURES,WILLS, PARTITIONS, CEILINGS OR FLOORS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN tURSI TO THE 'DER tlNN MPOIM WSW eo:Aeal.c sxur ICIIEWYsrEu N^� .W REDIICE NEC6905NCHIXN DANIEL PLACED FOR W SYSTEM THAT SHUT DOWN THE AWAY AND SON OUCFOW LEAVNG THE ARRAY LEVEL AFTER THE MICR0.INVE RIER OUTPUT TERMINALS) LOCATED NO MORE THAN 3 I AWAY FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE W SYS FEMS PRE CONNECTED AND AT ALL ICE RNFIED RAND SHUTDOWN SWITCHES I F NOT I N THE BASE LOCATION n NECONJUCC)C) LOCATED AT THE PRIMARY ROLE SHUT DOWN DISCO NNECT SWITCH O AWARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR NEC 70.12(9(8) IFBELLIMEDONLYIFTHEI EARE3OEMJNE Ll%'ATEO AT LOAD CENTERS CCNTPINNG 3 CR LORE 9JPRY,POWEROOURCES �® 10 ALL ELECTRIC POWER SOURCE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS GROUPED AND I COMBINER PANEL LABELEDWITHIN 30FT AND UNE OF SITE DO NOT ADD LOADS OF THIS LOCATION NEC 690.5MB) A IEC 705.10 All ELECTRICAL LOWER SOURCE DISCONNECTING MEANS ARE RED HIRED ATTAIN 10 Fi. AND WITHIN LINE OF SITE O THE MAIN SERVCE DISCONNECT LEEJONATHAN 3902 NELSON STREET WHEAT RIDGE COLORADO 80033 12812 3977 10511 NEC R512(BX2K3MB7 LACATED ON TLE W CIRCURIS) C NER PI DATE: 10/1 /2020 ID7 REVISION 1: REVISION 2: REVISION 3: LABELS DRAWN BV: DL INTERCONNECTION PHOTOS � 1172 oil &IrIG-0 Rainproof Combinat,c MC2D40B120W LC J NI.b.. r,x. ,e�.a-m q • SUITABLE ONLY FOR USE AS SERVICE EOUI Q{ •r' I 1 USE 30175 COPPER OR ALUMINUM WIM a. 2w+ww ..mwu 11L: Ng w am,WI—. ..e.a•I 11,, cam. owwvem. k. EMPIRE SOLAR GROUP LEE JONATHAN AT o 10 N11,20 R SION2 EMPIRE DEN RR CO 0299 NMEATRIDGECOLORADOSOME �EON3 •^ •• __^ LICENSE#E6010„1 12812 Irvrescorvrvccnory 3977 D RAW EVmL ME 1602 10511 DIRECTORY PLACARD TO BE INSTALLED ON MAIN ELECTRICAL SERVICE EMPIRE SOLAR GROUP EMPIRE 6535 YORK STREET UNIT 120 DENVER, CO 80299 .. .... LICENSE#EC-010111 ME: 1602 N CAUTION POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN MAIN SERVICE PANEL /AC DISCONNECT /INVERTER ARRAY 3902 NELSON STREET WHEAT RIDGE COLORADO 80033 LEEJONATHAN 3902 NELSON STREET WHEAT RIDGE COLORADO 80033 12812 39.77 105.11 U) 1a7220 DATE: 10/1/2020 + + REVISION 1: 1 1 REVISION 2: REVISION 3: DRAWN BY: DL Directory Placard IIki&If944=I:41M*o]kiIWd EMPIRE SOLAR GROUP EMPIRE 6535 YORK STREET UNIT 120 DENVER, CO 80299 .o' ^a .... LICENSE#EC-010111 LEEJONATHAN 3902 NELSON STREET WHEAT RIDGE COLORADO 80033 12812 39.77 105.11 DATE: 10/1/2020 REVISION 1: REVISION 2: 12 REVISION 3: DRAWN BY: DL Optimizer Map W HIGH EFFICIENCY PREMIUM MONO-PERC PV MODULE C E ❑� 40- - 0° Intertek Intertek EC M Fraunhofer • ISE CHUBB' *Chubb provides error and omission insurance to Silfab Solar Inc. i eee BAA/ARRA COMPLIANT Silfab panels are designed and manufactured to meet Buy American Act Compliance. The US State Department, US Military and FAA have all utilized Silfab panels in their solar installations. eee LIGHT AND DURABLE Engineered to accommodate high wind load conditions for test loads validated up to 400013a uplift. The light -weight frame is exclusively designed for wide-ranging racking compatibility and durability. QUALITY MATTERS Total automation ensures strict quality controls during the entire manufacturing process at our ISO certified facilities. SIL -330 NL -IN- TIME 1 $$$ I,WHFiCii IGH eee DOMESTIC PRODUCTION Silfab Solar manufactures PV modules in two automated locations within North America. Our 500+ North American team is ready to help our partners win the hearts and minds of customers, providing customer service and product delivery that is direct, efficient and local. eee AESTHETICALLY PLEASING All black sleek design, ideal for high-profi commercial applications. eee PID RESISTANT PID Resistant due to advanced cell techn selection. In accordance to IEC 62804-1. Test Cord itions STC NOCT Module Power(Pmax) Wp 330 235 Maximum power voltage (Vpmax) V 33.3 30.2 Maximum power current(Ipmax) A 9.92 7.8 Open circuitvoltage (Voc) V 40.5 36.7 Short circuit current (ISE) A 10.42 8.2 Measurement conditions: STC 1000 W/m2 • AM 1.5 • Temperature 25 °C • NOCT 800 W/m' • AM 1.5 • Measurement uncertainty s3% • Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics mavvary by±5% and Dower by 0 to +1 OW. Temperature Coefficient I Sic 0.064 %/°C Temperature Coefficient Voc -0.28 %/°C Temperature Coefficient Pmax -0.36 %/°C NOCT (±2°C) 46 oC Frame Anodized Aluminum (Black) lunction Box UL 3730 Certified. IEC 62790 Certified. IP67 rated uct workm a nsh i p warranty Linear power performance guarantee Pi ULC ORD C1703, UL1703, CEC listed***, UL 61215-1/-1-1/-2, UL 61730-1/-2, IEC 61215-1/- Product 1215-1/- Product 1-1/-2***. IEC 61730-1/-2***, CSA C22.2#61730-1/-2***, IEC 62716 Ammonia Corrosion; IEC61701:2011 Salt Mist Corrosion Certified, UL Fire Rating: Type 2 Factory IS09001:2015 eee Modules Per Pallet 26 eee Pallets Per Truck: 36 eee Modules Per Truck: 936 *A Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules. **12 yea r extenda ble to 25 years subject to regis- tration and conditions outlined under"Warrant/" at www.sIIItoo la uco Dr. ***Certification and CEC listing In progress. August 2020 expected completion date for CEC Asti ng, IEC 61730/61215 a no CSA C22.2#61730-1/-2 Thirdpartygenerated pan files from Fraunhofer - Institute for Solar Energy Systems ISE are available for download at www.silfabsolar.com/downloads Silfab Solar Inc. Sl 240 Courtneypa rk Drive East � Mississauga ON L5T2Y3 Canada S i Ifa b ' Tel +1 905-255-2501 1 Fax +1 905-696-0267 RaEUI info@silfabsolar.com I www.silfabsolar.com L• ©®Silfab Solar 800Cornw Inc. 800 Cornwall Ave 21100 TOP PERFORMER ,� � Bellingham WA 98225 USA FVMODOIE Tel+1 360-569-4733 RELIABILITY SOOREDARD Drawings not to scale 15"(38mN 7 r • g Sin le Phase Inverter with HD -Wave Technology m for North America ;a_ SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US /"i SE760OH-US/SE10000H-US/SE1140OH-US I..'.' 0) • o � r r cay Of 8 Optimized installation with HD -Wave technology Specifically designed to work with f Extremely small power optimizers J Record-breaking efficiency J Built-in module -level monitoring J Fixed voltage inverter for longer strings J Outdoor and indoor installation J Integrated arc fault protection and rapid shutdown for J Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) J UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge.com solar= @ @ z Single Phase Inverter with HD-Wave Tec n0 ogy for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA - 5100 3300 @ 208V 7750 5000 @ 208V 38.8/17.6 15500 W 10000 @ 208V Yes Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 27 30.5 Adc 3300 @ 208V - 5000 @ 208V - 13.5 - 10000 @ 208V 27 Adc AC Output Voltage Min. -Nom. -Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) 99 @ 240V o 98.5 @ 208V Nighttime Power Consumption < 2.5 W AC Output Voltage Min. -Nom. -Max. ✓ ✓ ✓ Vac (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 60.50) Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 24 48.5 A Current @208V GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 in / mm 7750 22110 25.1 / 11.4 26.2 / 11.9 38.8/17.6 15500 W Transformer less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VQ 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V«> - 9 - 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse- Polarity Protection Yes Ground -Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency gg 99 @ 240V o 98.5 @ 208V Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(3) Rapid Shutdown - NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum/ 14-6 AWG 1" Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range T' Maximum / 1-2 strings / 14-6 AWG T' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22110 25.1 / 11.4 26.2 / 11.9 38.8/17.6 Ib / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to +60(v (-40'F / -40'C option)v) 'F / -C Protection Rating NEMA 4X (Inverter with Safety Switch) "I For other regional settings please contact SolarEdge support ir' A higher current source may be used; the inverter will limit its input current to the values stated (I Revenue grade inverter P/N: SExxxxH-US000NNC2 (a� For power de -rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf (1 -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All RoHS other trademarks mentioned herein are trademarks oftheir respective owners. Date: 03/2019N01/ENG NAM. Subject to change without notice. Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 PV power optimization at the module -level Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization solaredge.com ��n N M Fast installation with a single bolt Next generation maintenance with module - level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module -level voltage shutdown for installer and firefighter safety solar -•• Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 INPUT Rated Input DC Powent 320 340 370 400 405 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125k) Sze Vdc MPPT Operating Range 8-48 8-60 8-80 125-105 125-87 Vdc Maximum Short Circuit Current (Isc) 11 101 14 Adc Maximum DC Input Current 1375 125 175 Adc Maximum Efficiency 995 % Weighted EfibenCA 988 986 % Overvoltage Category II IP68 / NEMA6P OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum OutputCurrnt e 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 t 01 Udc STANDARD COMPLIANCE EMC FCC Pa rt15 Class 3, AC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material U L94 V-0 , TV Resistant ROHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 1 10 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters (Power Optimizers) P405 / P505 6 Dimensions (W xLx H) 129x153 x275 /51x6 x11 129 x 153 x 335/ 129 x 159 x495/ 51x6x13 51x63x19 129x 162x 59/ 51x64x23 mm/in Weight(including cables) 630/14 750/17 845/19 1064/23 gr/Ib Input Connector MC4m Single or dual MC41dnn MC41') Input Wire Length 0 16/0 52 m /ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0 9/2 95 12/39 SE7600-US - SE11400- m/ft Operating Temperature Rangel') -40 - +85 /-40 - +185 12750h) -C/ -F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % N Rated power Othe module at STCwill not exceed the optimizer "Rated Input DC Power"_ Moduleswith up to s5%power tolerance are allowed m NEC 2017 requires may inpul voltage be not more than 80V raI For other cenneaor types please contact SolarEdge m For dual version for parallel cennecoon oftwo modules use the P405i In the ase plan odd number of PV modules in one fling, installing one P405 dual version power optimizer nI For ambient temperature above +85-C / +185-F power de -rating is applied_ Retards, Power Optimizers Temperature De -Rating Technical Note for more details_ Minimum String Length P320, P340, P370, P400 8 1 10 1 18 (Power Optimizers) P405 / P505 6 8 14 Maximum String Length 25 25 SOm (Power Optimizers) 5700 (6000 with Maximum Power per String SE7600-US - SE11400- 5250 60001') 12750h) W US) Parallel Strings of Different Lengths or Orientations Yes Is For detailed fling sizing information referto_ hnpy/wwwsolaredgemm/sites/defaulVfiles/string sizing-na_pdf N It is not allowed to mix Dm5/P505with P320O340O370/P400 in one fling P A fling with more than 30 optimizers does not meet NEC rapid shutdown requirements safety voltage will be above the 30V requirement m For SE144KUS/SE432KUS Itis allowed to install up to 6,500W per string when 3 flings are cennected dethe inverter Q strings per unit for SOS 2KUS) and when the maximum power Inference between the strings is up to f 0i he For SE30KUS/SE333KUS/SE666KUS/SE100KUS Itis allowed to install upto 15000 per fling when 3 strings are cennected tothe inverter flings per unitfor SE666KUS/SE100KUS) and when the maximum power Inference between the strings is up to 2,000W C 5olarEtlgeTechnologies Lid All ngMsreserved 5OLAREOGE, the SolarEtlgelogo ,OPTIMIZEOBY SOLAREDGE are trademarks or reglsceretltratlemarla of5olarEtlgeTechnologies, Inc . Lc/,,�L RoHS All other trademarks mentioned herein are trademarks of their respective owners. Date: OSS2019ABOCeNG NAM. Subject to change without notice. p\'/,� IMeRdC SOLARMOUNT � i�UNIRAC SOLARMOUNT is the professionals' choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25 -year warranty. Not only is SOLARMOUNT easy to install, but best -in -class aesthetics make it the most attractive on any blockf New & Im THE PH With Sup NOW FEATURING FLASHKIT PRO The Complete Root Attachment Solution TUTORING O SHED 6 SEAL TECHNOLOGY NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here, REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps SOLARMOUNT BETTER DESIGNS TRUSTTHE INDUSTRY'S BEST DESIGN TOOL Start the design process for every project in our U -Builder on-line design tool. It's a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and darkfinishesto optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Univac to help you minimize both system and labor costs from the time the job is quoted to the time yourteamsget off the roof. Faster installs Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we've got you covered. Visit Unirac.com/solarmount for more information. 9 N UL2703SYSTMECTANBONDING &GROUNDING MICA FFIRE CLLASOSIIFCATION :e'UNIRAC CONCEALED UNIVERSAL ENDCLAMPS UNIVERSAL SELF STANDING MIDCLAMPS I'7` r► , (�i, % END CAPS INCLUDED WITH EVERY ENDCLAMP U -BUILDER TOOL SAVE! Visit design um [I]►II1101111A(11]iv, IIkINI11TI1131iv, IV: 6111113,11[1li1:6111ATI IIIII]19iifl11114MI] 901RI UNMATCHED EXPERIENCE 9 CERTIFIED QUALITY TECHNICAL SUPPORT Come'stechnical supportteam is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheetsgreatly simplifies your permitting and project planning process. ENGINEERING EXCELLENCE a BANKABLE WARRANTY CERTIFIED QUALITY PROVIDER Univac isthe only PV mounting vendor with ISO certifications for 9001.2008,140012004 and OHSAS 18001.2001, which means we deliverthe highest standards for fit, form, and function. These certifications demonstrate our exec Ilence and commitment to first class business practices. IV, DESIGN TOOLS R1 PERMIT DOCUMENTATION BANKABLE WARRANTY Don't leaveyourprojectto chance, Univac hasthe financial strength to hack our products and reduce your risk. Have peace of mind knowingyou are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year limited product warranty and a 5 year limited finish warranty ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN PUB201BAUG31-PRINTED UPDATE FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2102 MPI SFM FRAME TM MICRDRAIL SYSTEM BONDING & GROUNDING 1 A INSTALLATION GUIDE : PAGE Star Washer is Single Use Only TERMINAL TORQUE, Install Conductor and torque to the following: 4-6 AWG: 35in-lbs 8 AWG: 25 in -lbs 10-14 AWG: 20 in -Ws LUG DETAIL & TORQUE INFO ILsco Lay -In Lug (GBL-4DBT) • 10-32 mounting hardware • Torque = 5 ft -Lb • AWG 4 -14 -Solid orStranded TERMINALTORQUE, Install Conductor and torque to the following: 4-14AWG: 35in-Ws LUG DETAIL &TORQUE INFO ILsco Flange Lug(SGB-4) • 1/47mounting hardware • Torque= 75 in -Lb • AWG4-14-Solid orStranded NOTE: ISOLATE COPPER FROM ALUMINUM CONTACTTO WEEBLUG Single Use Only TERMINAL TORQU� Install Conductor and torque to the following: 6-14AWG: 7ft-lbs LUG DETAIL &TORQUE INFO Wiley WEEBLug (6.7) • 1/47mounting hardware • Torque =loft -Lb • AWG 6 -14 -Solid orStranded System bonding is accomplished through modules. System grounding accomplished by attaching aground Lug to any module at a Location on the module specified by the module manufacturer. E -W BONDING PATH: E -W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicroraiLTM and splice. - - I IAI[emate method N -S BONDING PATH: N -S module to module bonding is accomplished with bonding clamp with 2 integral bonding pins. (refer also to alternate method ) I Ahemate mahod • TRIMRAIL BONDING PATH: TrimraiLto module bonding is accomplished with bonding clamp with integral bonding pin and bonding T -bolt. (refer alsoto alternate method) "`FRAME SFM FRAME UL CODE COMPLIANCE NOTES i •• -------� MICRORAIL-"" INSTALLATION GUIDE ----------------------------------------------------------------------------------------------------------------------------'I--PAGE------- SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the SUNFRAME MICRORAIL (SFM) Installation Guide. SFM has been classified to the system level fire portion of UL 1703. This UL 1703 classification has been incorporated into the UL 2703 product certification. SFM has achieved Class A, B & C system level performance for low slope & steep sloped roofs when used in conjunction with type 1 and type 2 modules. Class A, B & C system level fire performance is inherent in the SFM design, and no additional mitigation measures are required. The fire classification rating is valid for any roof pitch. There is no required minimum or maximum height limitation above the roof deck to maintain the Class A, B & Cfire rating for SFM. SUNFRAME MICRORAI Lm components shall be mounted over a fire resistant roof covering rated for the application. Module Type Roof Slope I System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 Steep Slope & Low Slope I Class A, B & C East-West Landscape OR Portrait None Required UL2703 TEST MODULES See page "S" for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 22.3 sgft • UL2703 Design Load Ratings: a) Downward Pressure — 113 PSF / 5400 Pa b) Upward Pressure — 50 PSF / 2400 Pa C) Down -Slope Load — 30 PSF / 1400 Pa • Tested Loads: a) Downward Pressure — 170 PSF / 8000 Pa b) Upward Pressure — 75 PSF / 3500 Pa C) Down -Slope Load — 45 PSF / 2100 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTRAE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span LABEL MARKI NGS • System fire class rating: See installation instructions for installation requirements to achieve a specified system fire class rating with Unirac. • Unirac SUNFRAME MICRORAILTm is listed to UL 2703. • All splices within a system are shipped with marking indicating date and location of manufacture. I 1 1 . • . 1 • . . • 1 1 • . . C . OWJ�L°t:�.'C� 2 VCH PUNMUM MOW- ENG�.37T 1 1.• I. I f t . 1 3 1 SFMMICRORAILTIMFRAME TESTED /CERTIFIED MODULE LIST �•• � INSTALLATION GUIDE PAGE --------------------------------------------------------------------------------------------------------------------------------------------- Manufacture Module Model/ Series Aleo P -Series CHSM6612P, CHSM6612P/HV, CHSM6612M, Asrronergy CHSM6612M/HV, CHSM6610M(BL)(BF)/(HF), JA Solar CHSM72M-HC AXN6M61OFAXN6P61OT, Auxin i. YY: 01, 02, 03, 09,10 AXN6M612T & AXN6P612T Axitec AXI Power,AXI Premlum,AXI Black Premium Boviet BVM661O, BVM6612 BYD P6K & MILK 36 Series Seraphim CS6V-M, CS6P-P,CS6K-M,CS5A-M, Sharp CS6K-MS, CS61--P, CS61--M, CS6X-P, CS6K-MS, Siltab CS6K-M,CS6K-P,CS6P-P,CS6P-M,CS31--P, Canadian Solar PowerXT CS31--MS, CS3K-P, CS3K-MS, CS1K-MS, CS3K, SolarWorld CS31-1, CS31--MB-AG, CS3K-MB-AG, CS6K, CS61-1, CS31F, CS3W, CS1H-MS, CS11--MS Centrosolar America C -Series & E -Series Suntech CF2xxMxx-01, CF2xxPxx-01, CertainTeed CTxxxMxx-02,CTxxxM-03, Sun Edison/Flextronics CTxxxMxx-04, CTxxxHC11-04 Dehui DH-6OM Eco Solargy Orion 1000 & Apollo 1000 FreeVolt Mono PERC GCL GCL P6 & GCL M6 Series Tesla TD -AN 3, TD-AN4, Hansol VBHNxxxSA17(E/G) & SA18E, Panasonic 1-B-AN1, 1-D-AN1 Hebene 36M, 6OM, 6OP, 72M & 72P Series Upsolar HT6O-156(M) (NDV) (-F), HT Solar VBHNxxxZAO3,VBHNxxxZAO4 Peimar HIT72-156(M/P) Hyundai KG, MG,TG, RI, RG,TI, MI, HI&KISeries ITEK iT, iT HE & iT SE Series Japan Solar 1PS-60&1PS-72Series Manufacture Module Model/ Series JAP6 60-xxx, JAM6-60-xxx/SI, JAM6(K)-60/ xxx,JAP6(k)-72-xxx/4BB, JAP72SYY-xxx/ZZ, JAP6(k)-6O-xxx/4BB, JAP60SYY-xxx/ZZ, JA Solar JAM6(k)-72-xxx/ZZ, JAM72SYY-xxx/ZZ, JAM6(k)-60-xxx/ZZ, JAM60SYY-xxx/ZZ. i. YY: 01, 02, 03, 09,10 i i. ZZ: SC, PR, B P, H iT, IB, MW linko 1KM & 1KMS Series Kyocera KU Series S -Energy LG xxx S1C-A5, LG xxx N1C-A5, Seraphim LGxxx01C(01K)-A5, LGxxxN1C(N 1K) -A5, Sharp LGxxx51CA5, LGxxxA1C-AS, LGxxxN2T-A4, Siltab LGxxxN 2T A5, LGxxxN 2W -A5 LG ELectronia PowerXT LGxxx52W-A5, LGxxxE1C-A5, LGxxx52W-G4 SolarWorld LGxxxN 1C(N1K)-G4, LGxxxN2W-G4, LGxxxS1C-G4, LGxxxE1K-A5, LGxxxN2T-15, Somali LGxxxN1K(N1C)-V5, LGxxxO1C(N2W)-V5, Suntech LR6-60 &LR6-72 Series, ONGI My Series & Optimus Series Sun Edison/Flextronics LR46O & LR472 Series Mission Solar Energy MSE Series Mitsubishi M1E & MILE Series Neo Solar Power Co. D6M & D6P Series VBHNxxxSA15 & SA16, Tesla VBHNxxxSA17 & SA18, VBHNxxxSA17(E/G) & SA18E, Panasonic VBHNxxxKAO1 & KAO3 & KAO4, Upsolar VBHNxxxZAO1,VBHNxxxZAO2, URE VBHNxxxZAO3,VBHNxxxZAO4 Peimar S(xxxM (FB/BF) Phono Solar PS -60, PS -72 Plus, Pro, Peak, G3, G4, G5, G6(+), G7, G8(+) O.Cells Pro, Peak L -G2, L -G4, L -G5, L -G6, L -G7 Manufacture Module Model/ Series PEAK Energy Series, PEAK Energy BLK2 Series, PEAK Energy 72 Series, REC TwinPeak 2 Series, TwinPeak 2BLK2 Series, TwinPeak Series Renesola Vitrus2 Series & 156 Series Risen RSM Series S -Energy SN72 & SN6O Series (4Omm) Seraphim SEG -6 & SRP -6 Series Sharp NU -SA & NU -SC Series Siltab SLA, SLG & BC Series Solaria PowerXT Sunmodule Protect, SolarWorld Sunmodule Plus Somali SS23O-265 Suntech STP Suniva My Series & Optimus Series Sun Edison/Flextronics F -Series, R -Series & FLEX FXS Series SunPower X -Series, E -Series & P -Series TP572,TP596,TP654,TP66O, Tale un TP672, H ipor M, Smart Tesla SC, SC B, SC BI, SC B2 PAO5, PDO5, DDOS, DEO6, DDO6, PEO6, Trina PD14, PE14, DD14, DE14, DE15, PE15H Upsolar UP-MxxxP(-B),UP-MxxxM(-B) URE D7MxxxH8A, D7KxxxH8A, D7MxxxH7A Vikram Eldora, Solivo, Somera Waaree AC & Adiya Series Winaico WSF&WSPSeries (;IIiiy p� Yingli YGE & YLM Series 8� tTi iT. Please seethe SFM UL2703Construction Data Report at Unirac.com to ensure the exact solar module selected Is approved for use with SFM Infinity is not compatible with module frame height of less than 32mm and more than 40mm. Seepage 1 for further informatior SFM FRAME MODULE MAINTENANCE'N on � MICRORAIL"" INSTALLATION GUIDE PAGE --------------------------------------------------------------------------------------------------------------------------------------------- 1:1aS[.I9aiXIM 1.Remove capbolt 2. Separate cap from base by moving east/west 3. Remove cap :�azRITA -*X1r_W3 1.Remove (2) cap bolts 2. Separate cap from base by moving east/west 3. Remove cap REMOVE MODULE. REVERSE STEPS TO REPLACE MODULE REMOVED :1I111:19(87111HIC991101A 11x9z181pill Wt1z1010169181zlz1a311 1. Loosen (3) cap bolts approx. 3 turns. MLPE CABLES 2. Slide entire floating splice away from module being removed. CAUTION: DO NOT FULLY REMOVE FASTENERS Bonding note: If both sides of array are bonded with NS Bonding Clips, as recommended, then no additional bonding is required for module maintenance. A If necessary, on the row of modules containing the module being removed, one additional bonding clip can be added to the edge of the array opposite of the edge with bonding clips already installed. This is only necessary when the module removal would break the bonding path. ELECTRICAL CONSIDERATIONS SUNFRAME Microrail is intended to be used with PV modules that have a system voltage less than or equal to that allowable by the NEC. A minimum 10AWG, 105°C copper grounding conductor should be used to ground a system, according to the National Electric Code (NEC). It is the installer's responsibility to check local codes, which may vary. INTERCONNECTION INFORMATION There is no size constraint beyond structural thermal expansion limits on how many SUNFRAME Microrails & PV modules can be mechanically interconnected for any given configuration, provided that the installation meets the requirements of applicable building and fire codes. GROUNDING NOTES The installation must be conducted in accordance with the National Electric Code (NEC) and the authority having jurisdiction. Please refer to these resources in your location for required grounding lug quantities specific to your project. The grounding / bonding components may overhang parts of the array so care must be taken when walking around the array to avoid damage. Conductor fastener torque values depend on conductor size. This racking system may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instruction 19 as ll] 11141Z619Z41IIQZI Conduct periodic inspections for loose components, loose fasteners or any corrosion, immediately replace any affected components. � FRAME CONSIDERATIONS &MAINTENANCE N "' SFM on --------------------------------------------------------------------------------------------------------------------------------------------- � M',C'RORA,LTM INSTALLATION GUIDE 'I PAGE ELECTRICAL CONSIDERATIONS SUNFRAME Microrail is intended to be used with PV modules that have a system voltage less than or equal to that allowable by the NEC. A minimum 10AWG, 105°C copper grounding conductor should be used to ground a system, according to the National Electric Code (NEC). It is the installer's responsibility to check local codes, which may vary. INTERCONNECTION INFORMATION There is no size constraint beyond structural thermal expansion limits on how many SUNFRAME Microrails & PV modules can be mechanically interconnected for any given configuration, provided that the installation meets the requirements of applicable building and fire codes. GROUNDING NOTES The installation must be conducted in accordance with the National Electric Code (NEC) and the authority having jurisdiction. Please refer to these resources in your location for required grounding lug quantities specific to your project. The grounding / bonding components may overhang parts of the array so care must be taken when walking around the array to avoid damage. Conductor fastener torque values depend on conductor size. This racking system may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instruction 19 as ll] 11141Z619Z41IIQZI Conduct periodic inspections for loose components, loose fasteners or any corrosion, immediately replace any affected components. March 12, 2020 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87102 Attn.: Unirac- Engineering Department Re: Engineering Certification for the Unirac Sunframe Microrail, SFM Infinity U -builder Software Version 1.0 PZSE, Inc. - Structural Engineers has reviewed the Unirac's Sunframe Microrail, proprietary mounting system constructed from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; and has reviewed the U - builder Online tool. This U -Builder software includes analysis for the 2" Microrail, 8" Attached Splice, 6" splice, and front trimrail. All information, data and analysis contained within are based on, and comply with the following codes and typical specifications: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05, ASCE/SEI 7-10, ASCE/SEI 7-16 2. 2006-2018 International Building Code, by International Code Council, Inc. w/ Provisions from SEAOC PV -2 2017. 3. 2006-2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV -2 2017. 4. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC -ES. Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 90 -180 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U -builder Engineering report. Cantilever: Per U -builder Engineering report. Clearance: 2" to 10" clear from top of roof to top of PV panel. Tolerance(s): 1.0" tolerance for any specified dimension in this report is allowed for installation. Installation Orientation: See SFM Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the short side. Attachment shall be staggered where ground snow load exceeds 10 PSF. 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Pagel of Experience I Integrity I Empowerment Testing: Values were based on UTR-299 testing provided by Unirac. Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-05, ASCE 7-10 & 7-16 Component and Cladding design. Notes: 1) U -builder Online tool analysis is only for Unirac SFM Sunframe Microrail system only and do not include roof capacity check. 2) Risk Category II per ASCE 7-16. 3) Topographic factor, kzt is 1.0. 4) Array Edge Factor YE = 1.5 5) Average parapet height is 0.0 ft. 6) Wind speeds are LRFD values. 7) Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U -Builder design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U -builder software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: Evaluate whether the U -Builder Software is applicable to the project, and Understand and determine the appropriate values for all input parameters of the U -Builder software. This letter certifies that the Unirac SFM Sunframe Microrail, when installed according to the U -Builder engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SFM 2" Microrail or 8" Attached Splice to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. If you have any questions on the above, do not hesitate to call. Prepared by: O PCO �CF� *ENNEi/y J PZSE, Inc.—Structural Engineers p Lv FQ Roseville, CA Page 2 of 2 tntertek Total Quality. Assured. AUTHORIZATION TO MARK (This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Address: 1411 Broadway Blvd NE Albuquerque, NM 87102 Country: USA Contact: Klaus Nicolaedis Phone: 505-462-2190 FAX: NA Email: klaus.nicolaedis@unirac.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA U.S.A. Control Number: 5003705 Authorized by: for Dean Davidso ,Certification Manager Eta us Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Standard(s): lat- Standard s : Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed -1] LTR AE -001-2012 Issued: 2012/10/23 Photovoltaic Module Racking Systems; Attachements 1 - 3 Pr Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev Product: PUB2019JUN17 with Annex North Row Extension Installation Guide Rev PUB2019FEB20 Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 21 -Oct -2019 ED 16.3.15 (20 -Apr -17) Mandatory tntertek Total Quality. Assured. AUTHORIZATION TO MARK (This authorizes the application of the Certification Mark(s) shown below to the models described in the Products Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listinc Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listinc Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may bE applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Address: 1411 Broadway Blvd NE Albuquerque, NM 87102 Country: USA Contact: Klaus Nicolaedis Phone: 505-462-2190 FAX: NA Email: klaus.nicolaedis@unirac.com �a7.zaza Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA U.S.A. Control Number: 5014989 Authorized by: 0-0 for Dean Davidso ,Certification Manager Eta us Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Standard(s): lat- Standard s : Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed -1] LTR AE -001-2012 Issued: 2012/10/23 Photovoltaic Module Racking Systems; Attachements 1 - 3 Pr Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev Product: PUB2019JUN17 with Annex North Row Extension Installation Guide Rev PUB2019FEB20 Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page 2of2 ATM Issued: 21 -Oct -2019 ED 16.3.15 (20 -Apr -17) Mandatory tntertek Total Quality. Assured. Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 102393982LAX-002 Original 11-A r-2016 Revised: 13 -May -2020 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use With Flat -Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1] Standard(s) Photovoltaic Module Racking Systems [CSA LTR AE -001:2012 Ed.2012/10/23] Applicant Unirac, Inc Manufacturer 2 1411 Broadway Blvd NE Address Albuquerque, NM 87102 Address Country USA Count Klaus Nicolaedis Contact Todd Ganshaw Contact 505-462-2190 Phone 505-843-1418 Phone FAX NA FAX klaus.nicolaedis@unirac.com Email toddg@unirac.com Email Manufacturer 3 Address Ci1�r � Country /07 •Z�Za,,, Contact Phone FAX Email Page 1 _of 113 This reW i:s W Ihe miusive rise cd Irrle ':s CIi"t ;DM0 is pigwi#W pwrSvW 101he 89feeffeN beTiften IMI.eftk ;)r4 it$ Qlie-nt InbFW's re r1*. P. ;y ;.3� : IiAbfty are linA*d b ft t$rrms and 1k�wns oif the agreenwv. I1ertek amums no Iiabdrty to any party. odiv than Io Lhe CIWO irl arAordarCR '+gift the ag•Terr*nrl, kv any Imo, expense or damage oczaskxbW Oy Me use oll ihyis ra re. Orrt lhyrr I>ent r5 aulhlon zed to pard 'g or di#tnb lion err MIS rqXO ard Ihen onlyin ill "W", AiTy u *F Ihe. IrKeMek n*nV or one Cd its Mark$ Fir the sale ew xNeMisement -of the 1e*1ed ma*60. pmohxt cw ftry rMat first be aD>mwed in wntirg by Inleriek. The observabons and test rfsuft in this report are relevant only to the sarroe testes This repw by RisMt does rii imply Ihst tt& maul prrodi,4, of sefv4e iS or has ever been under an Inlrrrtek C4Mfcabon program Report No. 102393982LAX-002 Page 2 of 113 Issued: 11 -Apr -2016 Unirac, Inc Revised: 13 -May -2020 2.0 Product Description Product Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2020MAY04 Brand name Unirac The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails within this product, whereas the 3" Micro Rail, Floating Splice, and 9" Attached Splice electrically bond the modules together forming the path to ground. The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized with black oxide with a stainless type 300 bonding pin, torqued to 20 ft -lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate the anodized coating of the photovoltaic module frame (at bottom flange) to contact the metal, Description creating a bonded connection from module to module. The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the revision in effect in the jurisdiction in which the project resides. Any local electrical codes must be adhered in addition to the national electrical codes. The Grounding Lug is secured to the photovoltaic module, torqued in accordance with the installation manual provided in this document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, which requires a minimum of 2 micro -inverters mounted to the same rail, and using the same engage cable. Ia.7.ZaZa ED 16.3.15 (20 -Apr -17) Mandatory Report No. 102393982LAX-002 Page 3 of 113 Issued: 11 -Apr -2016 Unirac, Inc Revised: 13 -May -2020 2.0 Product Description Models Unirac SFM Model Similarity NA Fuse Rating: 30A Module Orientation: Portrait or Landscape Maximum Module Size: 17.98 ft' UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down -Slope Tested Loads - 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope Trina TSM-255PD05.08 and Sunpower SPR -E20-327 used for Mechanical Loading Increased size ML test: Maximum Module Size: 22.3 ft2 UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down -Slope LG355S2W-A5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down -Slope Ratings LG395N2W-A5, LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift Fire Class Resistance Rating: - Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5" gap between the bottom of the module and the roof's surface See section 7.0 illustractions # 1, 1a, 1aa, and lab for a complete list of PV modules evaluated with these racking systems Other Ratings NA ED 16.3.15 (20 -Apr -17) Mandatory intertek UNIRAC INC. LETTER REPORT SCOPE OF WORK MOITI ON OF MODULES TO THE REPORT NUMBER 104430210NX{ID la ISSUE DATE 24 Sept 2020 PAGES 3 OOCUMENTCONTROLNUMBER GET OP10a(21- June 2019) 020191NTERTEK �J ntertek Total Quality. Assured. LETTER REPORT September 24, 2020 Klaus Nicolaedis Unirac Inc. 1411 Broadway Blvd NE Albuquerque, NM 87102-1545 USA klaus.nicolaedis@unirac.com 25791 Commercentre Drive Lake Forest, CA92630 Telephone: 9494484100 Facsimile: 949-4484111 www.intertek.com Intertek Report No. 104430210LAX-001a Intertek Project No. G104430210 Subject: Addition of modules to the Unirac SFM CDR 102393982LAX-002 Dear Klaus, Ph: 50- --- ---- This letter report represents the results of our evaluation of the above referenced product(s) to the requirements contained in the following standards: Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1] SECTION 1 SUMMARY This investigation was authorized by quote # Qu -01101732 dated 08-17-2020. The scope of the project was to evaluate and add module frames to the SFM CDR 102393982LAX-002. SECTION 2 EVALUATION The following PV modules were evaluated for bonding/grounding purposes and are approved to be installed using the Unirac SFM model: Manufacturer Model Q.PEAK DUO L -G7, Q.PEAK DUO L -G7.1, Hanwha Q Cell Q.PEAK DUO L -G7.2, Q.PEAK DUO L -G7.3, Q.PEAK DUO L -G8, Q.PEAK DUO L -G8.1, Q.PEAK DUO L -G8.2, Q.PEAK DUO L -G8.3 REC TP3M, TP3M Black Silfab SIL-xxx-NT, SIL-xxx-ML, SIL-xxx-NL, SIL-xxx-BL, SIL-xxx-HL This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Version: 6 -March -2017 Page 2 of 3 GFT -OP -10a tnterti?k Unirac Inc. Intertek Report No: Total Quality. Assured. 104430210LAX-001a LETTER REPORT PROJECT STATUS & ACTION Issuance of this letter report provides results of the evaluation covered by Intertek Project No. 6104430210. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact your dedicated Intertek Project Manager. Completed by: Abhinav Prakash Title: Project Engineer Signature: Date 09-24-2020 Reviewed by: Adam Muliawan Title: Reviewer Signature Date: 09-25-2020 Please note: this Letter Report does not represent authorization for the use of any Intertek certification marks. �a �.2azan Version: 6 -March -2017 Page 3 of 3 GFT -OP -10a wa_ln5l' INSPE��ION RECORD SPE TION ONLINE FORM: http://www.ci.wheatridge.co.us/forms.aspx?fid=79 0 Wr—INSPECTION REQUEST LINE: (303) 234-5933 Occupancy/TyVe Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Mid -Roof y Fire Inspection / Fire Protection Dist. Lath / Wall Tie Final Plumbing Rough Electric Final Mechanical Rough Plumbing/Gas Line Roof Rough Mechanical Final Window/Doors Rough Framing NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Fina Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather A City of 'Wheat Ridge Homeowner Roof PERMIT - 201702741 PERMIT NO: 201702741 ISSUED: 06/28/2017 JOB ADDRESS: 3902 Nelson ST EXPIRES: 06/28/2018 JOB DESCRIPTION: Reroof with composite shingle & tar paper replacement - 16 squares *** CONTACTS *** OWNER (720)448-3603 LEE JONATHAN & AMANDA CLAYTON *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,500.00 FEES Total Valuation 0.00 Use Tax 115.50 Permit Fee 140.90 ** TOTAL ** 256.40 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A1/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturerdelms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. I, the property owner, by my signature, attest that I currently reside at the project property, intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers. Consultations and inspections will only be performed with the homeowner of record present. •aug laafgns aql ui uoilaadsui aql jo ssaappu agl;nd asuald •uoilaadsui aql jo Nuiuiow aq; `uiu00:8 pun wn0£:L uaamjaq sn•oa•a2pi.iluagm-!3kn Isanba.iawildsui of slsanba i liuwa asuald -Sluo liuwa Xq pa;damu aq pin► sisanba i awil uoilaodsul 'xYa SSMISnB ONIMOT70A 3HS N02133dSNI uo3 xYa SSMISRS YJW Xd65:TT x8 3aYW 38 asnN smsmnDav aiuQ [piogjo Au?p[ing joigD jo 3mlu0is -uoiloodsui pial; of loafgns si xaom3o 1pno.iddd •uotlotpstinf sigl jo uoilpin2a.i io aouuwpio Cup .io apoo olgpoilddu /CUP Jo uoisino.id /Cup j6 uoiluloin up 30 lenoaddu up jo `.io3 Iiuuod u 34 of panzlsuoo aq lou llpgs Ituuad p jo Suquui2i to 3oupnssi aql '9 •uoisiniQ saainaaSS uoioadsul pup �uiplmg agi wojj 31iom Bons jo luno.iddu uolium inogltm Nlom lu3ouoo to paaoo.id lou llpgs pun suotioadsui pa.iinb31jju •}o Xoilod pagsilqulso glim oouupi000e ui uoisiniQ saoiA.iaS uoitoodsul puu nutpiing aul 4ilou iiugs ioplou liuuod oq f 'S luno.iddu ogioa s puu .ioi.id Inoglim .[aipm jo mog lu.mipu 3g13o •32uugo p ui silnsai llugs lugl pauito3.i3d oq llpgs .rauupw up 30 )i.iom oN 't •paoluumm'. lou s[ pun iuioogjo guipling jaigD agi jo uoii3.tosip ;)los agi iu si slimiod pa.ndxa3o uotsualxo to ooupnssi-agi •iiw.tod mou Xup3o Tunoiddn aoj saanp000a puu s3a3 `sivauiazinbw plupupls oql of loofgns aq llpgs liuuad mou u jo aouurissl •poutulgo oq of pa.iinl)oi oq � uw liuuod mau n `sa.iidxa liuuad sigi31 '£ aa� Iiwia Iuuini.to og13o31ug-auo of lenbo aaj e of ioafgns 34 Xuw puu luiotdjo uiplmg .io,,D oqi jo uoiia.iosip agi ip p3lutJi ogbopuw sXvp 081 upgl Slow ou jo uoisuolx3 ud •uoilp.iidxo jo alup aql of joild paniaoa.i PUL, �uili.tm ui appw oq isnw uoisuoixo lo3 sisan of •,Ciinilop3o ssolptufai 3oupnss�o al-ep 3111 J31Jp s,Cpp S9£ mdIX3 hugs iiuuod sigZ Z soinp000ld pup saioijod `suoilulnO3.i `saouuuip. d `solnlpls olquoilddu llu pup `sluownoop osogl glim 3oueildwoo 3ql of loo ns si pup suoilv!poods pup supldd 5uiXuudlu0003 pup uoifuoilddu I!Lwod agi ut papinoid uoliuuuojui 3ql uo posuq p3nsst spm liuuad siq 1 aipQ (auo aloiiD) 201 2gainlpu�iS x/49 •suoiluogioods pup sueld panolddu �iut/Cuudw000u ,sfi .io/put, ivawnoop sigl ui posolosip st pauuo;.tad oq of )ltom llp ipgi pup pauuoiiad aq of �laom agi of saiiipd se Iu3wnoop sigl uiglim pawpu soipilua lu opnloui of pazitollinp tllu al wp I lugl lsalpp .iogl.m3 I ituua sigl glim uoiiounfuoo ui p3no.iddu puu pogi.iosap Atom agi uuo3.iad pup iituia� sigl utulgo of pozi.ioglnu wp pup iWz)dozd agl jo .iaumo liSal agl Xq pozuoginu uaaq aneg 10 loumo lu�al a1 1 wu I 1pgi pup `sompamid pup samilod `sapoo lieioiunw algoilddu lip pup `sapoo ftplin� olquolydp `suoiiuoi}ioads pun suuld p3no.iddu w/Cuudw000u llu grim Xjdwoo itpi{s pouuojmd aq of Niom 3qi lugl lsolip Xga.iaq op `a.mlEu is w q `I saz-enbs 9T - gUatuaoPTdaz zadpd app -3 aTfuzlls agzsoduioo ugzM goo-iag 8TOZ/8Z/90 :SH'dIdXS 1S uosTaN Z06£ LTOZ/8Z/90 : clans SI IVLZOLTOZ IVLZQLI0Z -11WHAd J001d aaUMOMUog a�tp!H jeaqM 30 Sj!D NOIldIUDSaG HOP :ssaEQaV Eor ON ZIMEd City of .6 Wheat -Midge MUNITy DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a)_ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. **' Property Address: 2)90'2- �dJq Sal 8 c) ()3 3 p Y Property Owner (please print):-'IM��QCA VI , Property Owner Email: a M O VACil G( c. ( l Mailing Addressp:, (if different than property address) Address: Phone: r7Z0 City, State, Zip: ,�, �� 12tAn--- CD 8 -i� _:�� Arch itect/Engineer:� Architect/Engineer E-mail: Contractor: Contractors City License #: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION &RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) d OWE 5� � 0 C (e + C -��2� Y e��2�1t�1s� v�- J Sq. FULF Amps Btu's Gallons Squares li.J Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (WNE (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Electronic Sienature (first and last name): DATE: v L� ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ City of WheatP-jde COMMUNITY DEVELOPMENT g Official Certification of Property Owner Permit THIS IS TO CERTIFY that I, the property owner, by my signature, attest that I currently reside at the project property, or intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, list them on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property. Property Owner(s): Project Property: A o:vz d_� CI>yi-ori Notarized/signa Applicant State of Colorado } County of S��'��s9r. } ss 5Z)VA V "T-CJ V c4 (�o Eaa3 ,-_?� The foregoing instrument was acknowledged by me this C2) IoAA day of ) ,._me_ , 20 1-7 by Man 0.CC'4 TAMARA D ODEAN NOTARY PUBLIC STATE OF COLORADO NOTARY ID 20164015481 MY COMMISSION EXPIRES APRIL 22, 2020 My Commission Expires __�JU/20_Z� Notary Public i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: �' - E, , Job Address: 3 9 e 2 N c s c n S -}- Permit Number: 0 ► -7 J a _� 1-11 ❑ No one available for inspection: Time ` 3 7 &PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 --- -\ Date: Of/-,=) a 17 Inspector: ) Q DO NOT REMOVE THIS NOTICE M i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L129 - P711c\) Job Address: 3 9 c a IV e is©n S4 - Permit Number: 2 o i-7 D a 7 q t ❑ No one available for inspection: Time = -a I (RPM Re -inspection required: Yes DNo When corrections have been made, call for re -inspection at 303-234- Date:- 9/ a S 1,2 Inspector: _Tb DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 u b- /til . d Job Address: 3 C/o a A/ -e_ Isen S -4 - Permit Number: -D 0 1-7 c -a -7 '-11 ❑ No one available for inspection: Time )'3 - // AM4 Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303 -234 - Date: Inspector: DO NOT REMOVE THIS NOTICE is City of Wheat Ridge Commercial Electric PERMIT - 201705674 PERMIT NO: 201705674 ISSUED: 08/08/2017 JOB ADDRESS: 3902 Nelson ST EXPIRES: 08/08/2018 JOB DESCRIPTION: COMMERCIAL ELECTRIC INSTALL CIRCUIT FOR KIOSK, ONE DEDICATED 20 AMP CIRCUIT FOR KIOSK. *** CONTACTS *** OWNER (303)421-5250 SUB (303)761-6176 FRANK SANDOVAL Mark Heikkila 100201 Integrity Electrical Solutions *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 500.00 FEES Total Valuation 0.00 Use Tax 10.50 Permit Fee 26.50 ** TOTAL ** 37.00 *** COMMENTS *** *** CONDITIONS *** Work must comply with the 2014 NEC, 2012 IBC and other applicable codes and ordinances. Work is ubject to field inspection. 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications= applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�perm t. I further attest that I am legally authorized to include all entities named within this document as partes to the work to be performed anthat all w o be performed Is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I • This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2• This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief in, Official and may be subject to a fee equal to one-half of the originalermit fee. 3• If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change• of the natural flow of water without prior and specific approval. 5• The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 4.1aOssuance or granting of a,permit. 1 trued to be a permit for, or an approval of, any violation of any provision of any licable code or any ordiriaikc oI'r at o o - jurisdiction. Approval of work is subject to field inspection. Signature �M4g'T'O'%Aft' Date REQUEST SINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. I FOR OFFWFAUSE ONLY city" of.[ Date: / t_l >.44 M( J'N I I Y l) F V t I Eif m I'N I Plan/Permit # (, Building & Inspection Services Division ` 7500 W. 29'h Ave., Wheat Ridge, CO 80033 Plan Review Fee: Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits ci.wheatridge.co.us Building Permit Application Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: WSit cr4-) zt V Property Owner (please print): rr ,r v) K Setid o yet I Phone: 30 1/215 z5o Property Owner Email: -Pro n t(. sa nd O vo 18 f)a r-jj ef'5 M cd. c-_0 Mailing Address: (if different than property address) Address: City, State, Zip: ,. - • 1171*3 Architect/Engineer E-mail: Contractor: I h Phone: Go, Ivit ors Contractors City License #: /© � _ Phone: 303 -Z&1 & f -7(2 Contractor E-mail Address: S e i V i Ge &q) i n+z_ t t Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form -1�-COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APP L NCE REPAIR or REPLACEMENT OTHER (Describe) I n c, ct 4� C t re --vi i _A>r K 105 k (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) 4,5�o11 one dl,dl C04- d �zp 6tmp c Arco;-- -for K►©sk. Sq. FtJLF Btu's Amps Zd Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, casements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the infonnation provided on the application. CIRCLE ONE: (OWNER) CONTRACTO r (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTR/ACTOR) EIectronic Signature (first and last n9me�• DATE: /! ZONING COMMMENTS Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ Mailing Address: (if different than property address) Address: 1 -5 0. City, State, Zip: 041 ws Cite License #: 93MM 9=- OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application, 004400: (OWNER) (9t )I�A �T,6*))gr (AUTHORIZED REPRESENTATIVE) Awwwjt: mevievver: PUBLIC WORKS COMMENTS: Reviewer FIRE DEPARTMENT:: El approved w/ comments 0 disalif 20MUMMM MM Bldg Valuation: $-L� �Zr- INSPECTION RECORD OccuDancylTVne INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site 1 Call by 3:00 PM to receive inspection the following business day. i rr; eiF.a „z ! INSPECTOR MUST SIGN ALL'SPACES'PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR ':. INITIALS COMMENTS: Footings /Caissons Stemwall / (CEG) Concrete Encased or Monolithic Weatherproof/ French Dram Sewer Service Lines. Water Service Lines' ROUGHS Sheathing `2 Lath / Wall: tie Mid Roof Electrical Service Rough Electric Rough Plumbing Gas Piping .Rough Mechanical FINALS Electrical Plumbing .Mechanical t Roof Building Final Fire Department R'.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping `. SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. " *NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A:CERTIFICATE OF OCCUPANCY .NOR PERMISSION FOR OCCUPANCY. g OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED `Y �ollrOnr T"I • r w Mn rn�ew T� r wr wry ern ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Ff /loo( Job Address: 3702:- N(JSo 1 Permit Number: 01259s- No one available for inspection: Time AM/PM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date: 11-? q -o,? Inspector: z'> ✓ r, DO NOT REMOVE THIS NOTICE r, ♦ i CITY OF WHEAT RIDGE Bung Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: t` • 13 r, Job Address: S clop I-.Vf z r: , Permit Number: efi> 7 1) IN I r ❑ No one available for inspection: Time AMA IPPM/ Re-Inspection required: Yes No When corrections have been made, call for re-ins eottiion at 303-234-5933 Date: 1 Inspector: 1 S~ Ln ~ DO NOT REMOVE THIS NOTICE e :a i CITY OF WHEAT RIDGE Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: L,:) ~Le ry . 5 i Permit Number: 3 5_9 S° f ( ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234x933 Date: %~~,rJ n Inspector%"J;.f d DO NOT REMOVE THIS NOTICE City of 'Wheat Ridge / Residential Roofing PERMIT - 093575 PERMIT NO:093575:: ,ISSUED:. 10/22/2009 JOBADDRESS: . 3902 NELSON ST EXPIRES: 04/20/2010 DESCRIPTION:. Reroof 15.5 sqs ***.CONTACTS owner 303/803-6055 Martin Lopez sub 303/420-0986 Dan'.Cupit - 06-0114 Professional Roofing, Inc.' PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION: 0207 -BLOCK/LOT#: 0./. FEE SUMMARY ESTIMATED PROJECT VALUATION: 4,874.97. FEES Permit Fee 144.70 Total Valuation .00 Use ;Tax . 87.75 TOTAL 232.45 Conditions: 6 nail installation i& mid roof inspection required.' Board sheathing spaced more thana 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield.' required from eave edge to 2' inside exterior walls. ***Contractor/Property owner shallprovide -ladder(s) secured in place for. inpsections Subject to field inspection. I hereby certify. that the setback distances proposed by this permit application; are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions.. of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions :printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building code:(I.B.C) and all other applicable Wh a Ridge Orden for work under this permit. Plans subject to field inspection. Signature of contractor 'ner 'date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the 'laws of the State of Colorado and to. the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any. other applicable ordinances of the city. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration :date. An extension maybe granted: at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or `abandonmenthas not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year;full fees shall be paid for anew permit. 4. No :work of any. manner shall be done that will change they. natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive wrier o--,-.-1 i-----. 4... ,..:-a'..,,, The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or say other ordinance, law,, rule or regulation. All plan jpew subject to field inspections. Signature Cn' Building:. Official date INSPEC ION REQUEST LINE: (303)234-5933 BUILDING OFFICE:. (303)235-2855 REQUESTS MUST: BE MADE BY 3PM'ANY BUSINESS 'DAY FOR INSPECTION THE `FOLLOWING BUSINESS DAY. City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 CO[ORA~O Inspection Line: 303-234-5933 Building Permit Application Date: Plan Permit M Property Address Property Owner (please print): Phone: (~3-~'t~3-~~LOSS Mailing Address: (if different than property address) v i Contractor License 6011x( Phone. ~Q3 - e - 6980 Sub Contractors: Electrical City License Company: Plumbing City License Mechanical City License Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): CZ22)Construction Value: $ 01 riptionao~f Work> (as calculated per the Buildim a Valuation Data sheet) PSI: 'rQQ'/f Oj I 4 ~ a-1-5 -b Plan Review (due at time of submittal): $ v y✓ Sq. Ft./L.Ft add Squares 4LL:5-- BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) CO''nnNT~~R~~A,,CTO /orr PERSONAL REPRESENTATIVE-&(OWNER) CONTRATO ) PRINT NAME: S~Ou/r'I {'l C - SIGNATURE--------'- ate: z('-7Z-D Bldg Valuation: Contractor: fJ~~7 1 fl ed6e)1s ~12 4