Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3680 Miller Court
INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site ' Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day PERMIT: O C ADDRESS:jb"' , AIaC a JOB CODE:r- � Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS od- PERMITAOOOL62ADDRESS:. Mti�9.P�" �':% JOBCODE:14-U'-4re-, Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial ICA 1\— 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential ICA 1\— 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. i CITY OF WHEAT RIDGE Vr Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: E1 �t%L_ tr L P_C, 6S0LAL Job Address:. '2)(phO Mi L -L E --r— 0"r Permit Number: `-O 1-1 Q ?a(,2(e 15 s ❑ No one available for inspection: Time AMM Re -Inspection required: Yes No When corrections have been made, call fgzre-inspection at 303-234-5933 Date: KMY<b '0 DO NOT REMOVE THIS NOTICE tis City of Wheat Ridge Residential Electric PERMIT - 201708665 PERMIT NO: 201708665 ISSUED: 11/13/2017 JOB ADDRESS: 3680 Miller CT EXPIRES: 11/13/2018 JOB DESCRIPTION: Solar PV install; roof mount, flush mount, grid -tied 5.7 KW *** CONTACTS *** OWNER (303)420-1128 LUMPP RANDOLPH F SUB (303)577-9628 Andy Nyman 070159 Sunrun Installation Srvs. Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,659.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am t%e legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all ork to be pertormed is disclosed in this document and/or its' accompanying approved plans and specifications. SignatureeR OWkER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made -be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and_procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of heat P,�dgc Building & Inspection Services Division 7500 W. 29`h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: Plan/Permit # Plan Review Fee: r Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3u -'go A %z�_"�_� (, Property Owner (please print): 9)1©jWtr l GU,l.'ll"P Phone:TOS-40.- f r29 Property Owner Email: Mailing Address: (if different than property address) Address: State. Zia: Architect/Engineer: Architect/Engineer E-mail: Contractor: - '0/,%'anxf Pho Contractors City License #: 070 IS C7 Phone: Contractor E-mail Address Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT R ELECTRICAL SYSTEM/APPLIANCE AIR or REPLACEMENT THER (Describe) SQtAt2 fV (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application-, that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNS) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME:SIGNATURE.y� L�� DATE: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer.�b) ( l , - , -'" ------ PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received Water District ❑ Received Sanitation District ❑ Received DEPARTMENT4fSE ON OCCUPANCY CLASSIFICATION: ❑ Not Required ❑ Not Required ❑ Not Required Building Division Valuation: $ Technical ippcif cation fr�det Solis- Solis- Solis- Solis- Solis- Solis - 2,51K -213 -US 3K -20 -US 3.6K -2G -US 4K -20 -US 4.6K -20 -US 5K -20 -US Energy Source PV DC Values Max usable input current per MPPT (Amps) 10+10 10+10 Max Short Circuit Current (Amps) 1:5.6+15.6 15.6+15.6 Start- llpVottage (Volts) Max Voltage (Volts) Operating MPPT Voltage Range (Volts) Full Power MPPT Voltage Range (Volts) Max Power per MPPT (.'Watts) Number of MPPT Inputs per MPPT AC Vatues(240Vac) Operating Voltage Range (Volts) Operating Frequency Ranqe (Hertz) Ambient Operating Temperature Range (Celsius and Fahrenheit) Ambient Humidity Range AC Output Power Factor Grid THD Nominal Power Output (Watts) Continuous Power Output (Watts) Maximum Continuous AC Output Current (Amps) Efficiency Peak Efficiency CEC Weighted Efficiency MDPT Efficiency Protection Max Overcurrent Protection Deuce (Amp Rating) Temperature Protection DC Reverse Polarity Protection 0_rtput Overvoltage Protection Anti-Islanding Integrated AFCI (DC arc fault) Integrated DC Switch Rapid Shutdown (NEC 690.121 City of Generat Data 125-500 5000 1 150-500 5000 1 2500 3000 2800 3300 10.4 12.5 97.5% 97.5% 95.5% 96.5% 20 20 10+10 10+18 15.6+15.6 15.6+28.1 120Vdc 600 100-500 180-500 145-500 5000 5000 2 1 1+2 211 -264 59.3-60.5 -25°C to 60°C / -13°F to 140°F 0-100% Condensing >0.99 <3% 3600 4000 4000 4400 15.0 16.7 97.5% 97.8% 96.5% 97.0% 993% 20 30 Yes Yes Yes (Varistor) Yes Yes Yes Optional 10+18 10+18 15.6+28.1 15:6+28.1 165-500 180-500 5000 5000 1+2 1+2 4600 5000 5000 5000 19.2 20.8 97.8%u 97.8% 97.0% 97.0% 30 30 Dimensions (Inches) wheat Rtdge 13.5' x 25.9" x 6.8' (338mm x 658mm x 173mm) Weight (Pounds) 33.1 lb. 38.1 lb. Topology Building Division Transformer -less Internal consumption (Watts) <1.0 Enclosure Type NEMA 4X (I P65) Cooling Type Natural Convection Noise Emissions <30 dBA Max operating altitude -without de -rate 13,120 feet (4000m) Compliance UL 1741, UL 1998, UL 169913, IEE 1547, FCC Part 15 (Class B), CAN/CSA22.2107.1-1 Features D splay Communication Conduit Knockouts War-ra ntv 0 SOUS Made by Ginlonq Tr chnologies LCD, 2x20Z RS 485 Modbus/Wi-Fi (CPRS optional) interface Two (2) on side and two (2) on bottom, 1", 1'/4" ID, Standard 10 Year (Extendable to 20 Years) t: 866.438.8408 1 e: sates@giniong-usa.com I w: www.gintong-usa.com L crab o Solis inverters 2.5kW to 5kW Ginlong Solis U'—:Version Single Phase Inverers Leading Features • Compact and Lightweight design inside a corrosion -resistant NEMA 4X enclosure Accessories A: iKerff'19 • Easy to install and visually pleasing for indoor or outdoor installations • Single phase 240Vac output WIF1 Stick • Up to 97.8% efficient with an ultra-low start up voltage • Dual (2) MPPT designs with fast (< 5 sec.) MPPT response times Web Box • Industry -Leading (1 00-50OVdc) wide dc input voltage range • Integrated Arc Fault Circuit Interrupt (AFCO option • RS485 Modbus communication protocol with Wi-Fi Rapid interface (optional GPRS) 0 Web based data monitoring with downloadable s Shutdown Solis Web App. j Device 0 10 Year Standard Warranty with extension options 1060 M I r t: 866.438.8408 GinLong Technologies 565 Metro Place South e: saLesgginLong-usa.com Ltd., Ningbo, Zhejiang / Suite 3214, Dublin, OH 0 w: ginLong-usa.com P.R. China 43017 USA GINLONG Technical Specifications DC Maximum I nput and Output Voltage CC Input Voltage Range Maximum Numberof PVSource Circuits Maximum Input/Output Current Maximum Short Circuit Current DC Input/ Output Cable Whips DC Input /'Output Wire Size Ground WireSize AC Rated AC input Voltage Rated AC Input Current Rated Frequency AC Control Wire Size Maximum AC Fuse Rating GENERAL Ambient Temperature Range Enctasure Type Roof Mount Style Status Indicator Eff iciency Response Time Dimensions (W x P x D) Weight Warranty Certification & Safety Standard Compliance 1 art Input -1 Output City of Wheat Ridge Building Division 2 or 3 Input -2 Output Sous-RSD1 L-1 G 600VDC 30-60OVDC 1 or input/ 1 output 20A 31.2A PVWire with MC4 Locking Connectors AWG 912 to ##6 ANJG #10 to #6 208/240VAC 0.1A 50/60Hz AWG #18 to #10 2A -25 to +65°C (-13 to 158°F) NEMA 4X Rait-mount plate (WEER Compatible) LED >99.5% <2 seconds 262 x 240 x 60 cm/ 10.3 h 9.4 x 02.36 in. 2.3 kg /5.1 lb 10 Year UL1741, FCC Part 15 Class B, NEC 690.12 Sotis-RS1012L-10 60OVDC 30-60OVDC 2 or3input/ 2 output 2 independent channels, 20A/10A 31.2A PV Wi rewith MC4 Locking Connectors AWG #12 to #6 AWG #10 to #6 208/240VAC 0.1A 50/60Hz AWG # 18 to #10 2A -25 to +65'C (-13 to 158'F) NEMA 4X Rail -mount plate (WEER Compatible) LED >99.5% <2 seconds 262 x 240 x 60 cri 10.3 x 9.4 x 2.36 i n. 2.4 kg / 5.2 lb 10 Year UL1741, FCC Part 15 Class B, NEC 690.12 VPCO CC AC Bulkr-d 240VAC Cornxtors RSDP.— Connectors Sons ............r � �:^, ........ ,T.. �........... —tee 1►--. Rapid Shutdown j�_j Rapid ShuttlDwn oo Poo— 1:1 MC4 DC Cor MOD's RSD Input 20A PV Source RSD output: 20A PV Circuit Input Output Circuit PV Source Chcult Ch.Copdutt 7,',Ca 7C AC Bulkhead 240VAC [p�ret tors Connector RSD. ---r —tee 1►--. $p115 ............0 W.......... ...... /�..`i,..... j Rapid ShuttlDwn oo Poo— MCC DC MC4 Connertcrs RSD IC2ut: RSD Output: 20A + 10A 20A + 10A Source Circuit Inputs Pv Output Circuits PV Source Circuits One Cp dut Solis Transformer -less String Inverter I Inverter (AC) Chrtput Circuit Salts Transformer -less String Inverter tnverter;AQ Ctutput circuit - � Solis Made by einlong Technologies t: 866.438.8408 1 e: ussates@glntong.Com ! vv: www.giniong.com a a Solis inverters Sobs- RSD 1L -1G SoUs-RSD2L-1G Ginlong Solis Rapid Shutdown Device • Certified to UL1741 Standard and compliant with 2014 NEC 690.12 Rapid Shutdown • Available in either single channel output or dual channel output allowing for perfect alignment with the number of MPPT channels in the inverter system • No interference with AFCI functionality of Solis inverters • NEMA 4X Enclosure, conformal -coated internal components and a wide operating temperature range • Low profile design allows for easy positioning under the PV module • Pre -wired MC4 connectors for positive, watertight connections • Engineered for the US Solis transformer -less Inverter Line and compatible with any PV Module -string inverter combination where the maximum system operating voltage is <_550VDC. t El 2.5k\&/ to 5kW 6kW to 1 Ok\N MORE r t: 866.438.8408 Ginlong Technologies 565 Metro Place South V e. ussales@ginlong.com Ltd., Ningbo, Zhejiang /Suite 3214, Dublin, OH V ❑� GINLONG ..++. i w: www.ginLong.com P.R. China 43017 USA i Bonding Adjustable X - End Clamp Top Bonding Adjustable X - End Clamp Bottom SnapNrack Bonding Adjustable X -End Clamp Bonding Standoff Clamp Rubber Rain Collar Mill Finish Standoff Mill Finish Standoff Base (1 Hole Base Shown) SnapNrack Bonding Standoff Assembly Bonding Mid Clamp Bonding Channel Nut SnapNrack Bonding Mid Clamp a Bonding Channel Nut L Foot L Foot Flashing SnapNrack Bonding L Foot Base with Flashing Bondging Splice Insert Splice Base SnapNrack Bonding Standard Rail Splice Bonding Channel Nut 90 L Foot Metal Roof Base SnapNrack Metal Roof Base with Bonding L Foot Bonding Universal End Clamp (UEC) Wave UsECPull Strap UEC Wedge SnapNrack Bonding Universal End Clamp SnapNrack- •• UL TechnicalData Patent Pending Materials - 6000 Series aluminum • Stainless steel - Galvanized Steel Flashing Material Finish - Clear and black anodized aluminum - Mill Finish on select components Installation • Quick and efficient mounting • Adjustable hardware to ensure clean and level finish - All components bonded to ground with integrated bonding features Calcs. & Certifications - UL 2703 Certification • Stamped Structural Engineering Reports for all SO States Grounding • SnapNrack Grounding Lug Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) City of Snaprack- Vti�he it Ridge (877) 732-2860 www.SnapNrack.corn Building Division Printed on recycled paper using soy based inks. :> 2014 by SnapNrack PV Mounting System. All rights reserved. The SnapNrack line of solar mounting systems is designed to reduce total installation costs. The system features technical innovations proven on more than 30OMW of solar projects to simplify the installation and reduce costs. Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 UL is listed to the UL 2703 Standard for Bonding, meaning that all system components have been certified by UL for electrical continuity, eliminating the need for additional grounding hardware. The System's components provide an adequate bonding path which has eliminated the need for grounding lugs and washers at each module, and bonding jumpers between splices. The UL 2703 Certification ensures that SnapNrack partners can provide the best in class installations in quality, safety, and efficiency. All bonding hardware is fully integrated into the components No grounding lugs required for modules Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required Patent Pending Roof System in 4 Simple Steps: 1) Go to the online Series 100 Configuration Tool (configure.snapnrack.com) and select "Yes" for UL 2703 Listed 2) Identify Site Conditions (Array Tilt, Building Height, Roof Type, Wind and Snow Loads) 3) Build array in the online Configuration Tool and automatically generate a Bill of Materials. 4) Place order with your distributor. Purchase material for a single project or order in bulk for additional savings - Rail & Module Clamps Roof Attachments Array Accessories L LISTED PV Mounting System 2703 &sunrun C�; October 26, 2017 Subject: Structural Certification for Proposed Residential Solar Installation. Job Number: 501R-680LUMP; Plan Set: Rev A, Dated 10/25/17 Client: Randolph Lumpp Address: 3680 Miller Ct, Wheat Ridge, CO, 80033 Attn: To Whom It May Concern A field observation was performed to document the existing framing of the above mentioned address. From the field observation, the existing roof structure was observed as Composition Shingle roofing over roof plywood supported by 2x6 Rafter @ 24" OC. The roof is sloped at approximately 11 degrees and has a max rafter span of 9' 3" between supports. Design Criteria: • 2012 International Building Code • Basic Wind Speed Vult = 135 mph (Vasd = 105 mph), Exposure C • Ground Snow Load = 30 psf After review of the field observation report, the existing roof framing supporting the proposed solar panel layout has been determined to meet or exceed the requirements based on our structural capacity calculations in accordance with applicable building codes. Therefore, no structural upgrades are required. If you have any further questions on the above for mentioned, please do not hesitate to call. oRP� U�� Sincerely,toA - .. V • C. F�a•� 0 i y Sage Lopez, P�Y 51 9 Civil Engineer •'r� Sunrun, Inc ���� , •���,` 'G ,ZONAL Et Exp. 10-31-2019 Oity of �he�t &iclge Qu!l 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 `a.'sun run CV Structural Calculations for the Randolph Lumpp Residence PV Installation Date: Job Address: Job Number: Scope of Work 10/26/2017 3680 Miller Ct Wheat Ridge, CO, 80033 501R-680LUMP These calculations are for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Calculation Index Sheet Description 2 Structural Geometry, Live Load, Snow Load, Wind Load, & Dead Load 3 Roof (1) Framing Check 4 Roof Attachment Check, Seismic Check, & Scope of Work Engineering Calculations Summar Code: 2012 International Building Code ASCE 7-10 Snow Load: S = 30 psf Live Load: LL = 20 psf Wind: Wind Speed Ult. (V) = 135 mph PV Dead Load: Sincerely, Sage Lopez, P.E. Civil Engine Sunrun, Inc DPV = 3.0 psf 149 AL Exp. = C City of Wheat Ridge Building Division Exp. 10-31-2019 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.383.0993 TM Structrure Geometr Engineer: SVL Date: 10/26/2017 Job: 501R-680LUMP Address: 3680 Miller Ct Wheat Ridge, CO, 80033 2 of 4 Mean Roof Height, hn = 12 ft Eave Height, he = 8 ft Buiding Length, L = 60 ft Building Width, B = 25 ft Module Area = 20 ft' Roof Pitch, 8 = 11 degrees Live Load: = 0.9 Roof Live Load, Lr = 20.00 psf Equation 4.8-1 Snow Load Ground Snow Load, pg = 30 psf Fig. 7-1 Table 1.5-1 Snow Importance Factor, k = 1 Table 1.5-1 5.0 psf Thermal Factor, Ct = 1.1 Table 7-3 1.00 Exposure Factor, Ce = 0.9 Table 7-2 Adjustment Factor, A = Roof Slope Factor, C5 = 1.00 Figure 7-2c City of Flat Snow Load, Pf = Sloped Roof Equation 7.3-1 Figure 30.5-1 Sloped Roof Snow Loads, N = 30.00 psf Equation 7.4-1 Wheat Is the width of the roof > 20ft? Yes Pnet30 = Ridge Drift Height, hd = 1.44 ft Figure 7-9 Building Division Roof slope for a rise of one, S 5.14 -52.53 Equation 30.5-1 Unbalanced Width = 8.68 ft Fig 7-5 Zone 3 (psf) V = 18 pcf Equation 7.7-1 17.25 Unbalanced Snow Load = 41.33 psf Fig 7-5 12.52 Wind Load: 12.52 Equation 30.5-1 Basic Wind Speed (3s -gust), V = 135.0 mph Figure 26.5-1A Building Occupancy Category = 2 Walls - Exterior Table 1.5-1 Composition Shingle Exposure Category = C 5.0 psf Sec 26.7.3 2.0 Topographic Factor, KZT = 1.00 2x6 Rafter @ 24" OC Equation 26.8-1 Gypsum Adjustment Factor, A = 1.21 1.0 Figure 30.5-1 2.0 Edge Zone, a = 3.00 ft Figure 30.5-1 Total Roof DL = Uplift (0.6W) Zone 1 (psf) Zone 2 (psf) Zone 3 (psf) Pnet30 = -29.20 -48.15 -72.35 Figure 30.5-1 Pnet = 0.6 x A x KZT x Pnet30) _ -21.20 -34.96 -52.53 Equation 30.5-1 Downward (0.6W) Zone 1 (psf) Zone 2 (psf) Zone 3 (psf) Pnet30 = 17.25 17.25 17.25 Figure 30.5-1 Pnet = 0.6 x A x KZT x Pnet30 = 12.52 12.52 12.52 Equation 30.5-1 Dead Load: Roof (1): Roof Walls - Exterior Composition Shingle 3.0 psf Wood 5.0 psf 5/8 OSB Sheathing 2.0 2x4 Studs @ 16" 2.0 2x6 Rafter @ 24" OC 1.0 Gypsum 3.0 Misc. (Ceiling, Insulation, etc.) 1.0 Misc. (Insulation, etc.) 2.0 PV System, Ppv 3.0 Total Roof DL = 10.0 psf Total Wall DL = 12.0 psf 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 TM Roof (1) Framine Check Engineer: SVL Date: 10/26/2017 Job: 501R-680LUMP Address: 3680 Miller Ct Wheat Ridge, CO, 80033 3of4 Roof Framing = 2x6 Rafter @ 24" OC Timber Species = Doug Fir -Larch #2 Max Beam Span = 9.25 ft b = 1.5 in d = 5.50 in Moment of Inertia, Ix = 20.80 in° Section Modulus, Sx = 7.56 in Bending Stress, Fb = 900 psi Elastic Modulus, Emin = 580000 psi Wood Adjustment Factors PV Tributary Width, Wpv = PV Tributary Length, Lp� = PV Tributary Area, At = PV Dead Point Load, PD = Ppv x At = Roof Distributed Load, wDL = Load Case: 0.6DL+0.6W (CD = 1.6) Roof Zone = Pup = Pnet x At + 0.6 x PD x cos(0) = Mb(wind_up) = Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF xCfu XCi xCr = Mallowable = Sx X Fb' (wind) = Load Case: IDL +0.6W (CD = 1.6) Pdown = Pnet X At + PD X COS(e) = Mb(wind_down) = Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu XCi xCr = Mallowable = Sx x Fb' (wind) = Load Case: DL + 0.75(0.6W) + 0.75S (CD = 1.6 Roof Snow Distributed Load, wSL = Psnow = Ps At = Mb(wind_snow) = Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu XCi XCr = Mallowable = Sx X Fb' (snow) = CD (Wind) CD (Snow) CLS CM Ct 1.60 1.15 1.00 1.00 1.00 CL CF Cfu Ci Cr 1.00 1.30 1.00 1.00 1.15 2.75 ft 4.0 ft f (Yof 11.0 ft2 32 Ib hE'citRldO� 14 plf 8uildin 9 Dlyision 1 214 lb 332 Ib -ft 2153 psi 1357 lb -ft > 332 OK 170 Ib 389 lb -ft 2153 psi 1357 lb -ft > 389 OK 60 plf 324 Ib 724 Ib -ft 2153 psi 1357 lb -ft > 724 OK Load Case: DL + S (CD = 1.15) Roof Snow Distributed Load, wSL = 60 plf Psnow = Ps x At = 324 Ib Mb(snow) = 683 lb -ft Fb' (snow) = Fb XCD XCLS XCM XCt XCL XCF xCfu XCi xCr = 1547 psi Mallowable = Sx x Fb' (snow) = 975 Ib -ft > 683 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 OK Rafter Attachments: 0.6D+0.6W (Zone 2) Puplift = At x Pnet = 365 Ib Connector Uplift Capcity per SnapNRack Test Results = 500 Ib 5/16" Lag Screw Withdrawl Value = 266 Ib/in Lag Screw Penetration = 2.5 in Allowable Capacity with CD = 1064 Ib Seismic Check: Engineer: SVL Date: 10/26/2017 Job: 501R-680LUMP Address: 3680 Miller Ct Wheat Ridge, CO, 80033 4of4 > 365 OK Table 11.2A - NDS > 365 OK /omcrease = (Wtotal + Warray) / Wtotal = 27856 *100%-100% = 3.86% ** 26820 **The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on applicable building codes, professional engineering inspection and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. L;;ty of Wheat I;icf tg Building Oiyisf., 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 Existing Dead Load: Solar Dead Load: Aroofexisting = 1500 ft2 Wpanel = 42 Ib Wroofexisting = 10500 lb Numpanel = 20 Awallexisting = 1360 ft2 Wpanel_tot = 840 Ib Wwallexisting = 16320 lb Wbos = 196 lb Wtotal = 26820 lb Warray = 10361b /omcrease = (Wtotal + Warray) / Wtotal = 27856 *100%-100% = 3.86% ** 26820 **The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on applicable building codes, professional engineering inspection and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. L;;ty of Wheat I;icf tg Building Oiyisf., 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 -,rFRIED 1675±2.5 [65.94 ±0.11 _.. b 28[1.1[ _ 910[35.81 382.5[5051 F-1 ,W0 + M c11±0.2 e [0.43 ±0.81 20.5±05 [0.78±0.08] M_,12001471 t +a +-aeusl 38 [1.51 Measurementsinmmlin] s EFFICIENCY ur YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY 1� US IMPORT DUTY FREE TEMPERATURE RATINGS Nominal operating cell temperature(NOCT) 44.6°C(±2°C) Temperature coefficient ofPmpp -0.36%/°C Tem peraturecoefficient ofVuc -0.30%/°C Temperature coefficient of I, 0.066%/°C Nominal Power -Pmpp(Wp) 275 280 285 290 295 Celltype. 6strings of20RECHCmulticrystallinePERC Watt Class Sorting -(W) 0/+5 0/+5 0/+5 0/x-5 0/+5 Glass: 013"(3.2 mm) solar glass with Nominal Power Voltage -Vmpp(V) 31.5 31.7 31.9 32.1 32.3 anti -reflective surface treatment Nominal Power Current - Impp(A) 8.74 8.84 8.95 9.05 9.14 Backsheet: Highly resistant polyester polyolefin construction Open Circuit Voltage -Voc (V) 38.2 38.4 38.6 38.8 39.0 Frame: Anodized aluminum Short Circuit Current-Isc(A) 9.52 9.61 9.66 9.71 9.76 (Available in silverorblack) Panel Efficiency(%) 16.5 16.8 17.1 17,4 177 Junction box: IP67 rated, 3 -part with3 bypass diodes 12AWG (4 mm2) PVwire, 35"+47" (0.9m -1.2m) Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m� cell temperature 25°C). At low irradiance of 200 W/m2 (AM 1,5 and cell temperature 25*C) at least 95% ofthe STC module efficiency will be achieved. Connectors: Staubli MC4 PV-KBT4/PV-KST4, 'Where xxx indicates the nominal power class (P_) at STC above, and can be followed bythe suffix BLKforblack framed modules. 12 AWG (4 m m2) Origins: Silicon: Made in USA &Norway ELECTRICAL DATA @ HOCT Product Code*: RECxxxTP2 Wafer/Cell/Module: Made in Singapore MAXIMUM RATINGS Nominal Power-Pmpp(Wp) 206 210 214 218 223 Operational temperature: -40...+185°F(-40_ +85°C) Nominal Power Voltage -Vm,IV) 29.2 29.4 29.6 29.8 30.0 Maximum system voltage: 1000V Nominal Power Current -Impp(A) 7.07 7.15 7.24 7.32 7.43 Design Loads: (+)75.21bs/ft2(3600Pa) Open Circuit Voltage -Voc(V) 35.4 35.6 35.8 36.0 36.2 (-) 33.4 lbs/ft2 (1600 Pa) Short Circuit Current-Isc(A) 7.52 7.59 7.68 7.75 7.85 Refer to installation manual Nominal operating cell temperature NOCT (800 W/m� AM1.5,windspeed1 m/s, ambient temperature 20*C) Max series fuse rating: 20A *Where xxxindicates thenominalpowerclass(P_)atSTCabove,andcanbefollowedbythesuffixBLKforblackframedmodules. CERTIFICATIONSMECHANICAL Max reverse current: 20A DVE QFolSA 10 year product warranty 25 year linear power output warranty DATA Dimensions: 65.9x39.25x1.5(1675x997x38mm) c us Area: 17.98 ft2 (1.67 m2) UL1703, Fire classification Type 2; IEC 61215, IEC 61730, (max.degressioninperformance of0.7%p.a.from thefirstyear) 97%after Weight: 40.8 lbs (18.5 kg) IEC61701(SaltMist-severityleve(6),IEC62804(PIDFree), IEC 62716 (Ammonia Resistance), ISO 11925-2 (Ignitability Class 1), See warranty conditions for further details. UN 18457/9174 (C lass A), ISO 9001:2015,15014001, OHSAS18001 Notel Specifications subject to change without notice. REC City of www.recgroup.com Wheat Ridge Building Division INPEAK 2 SERIES PREMIUM SOLAR PANELS 100% MADE IN SINGAPORE REC TwinPeak 2 Series solar panels feature an innovative design with high panel efficiency and power output, enabling customers to get the most out of the space used for the installation. Combined with industry-leading product quality and the reliability of a strong and established European brand, REC TwinPeak 2 panels are ideal for residential and commercial rooftops worldwide. INTEGRATED MANUFACTURING SINGAPORE SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION PV -1.0 COVER SHEET • SYSTEM SIZE: 570OW DC, 5000W AC • ALL WORK SHALL COMPLY WITH 2014 NEC, 2012 IBC, MUNICIPAL CODE, AND rS El SERVICE ENTRANCE SOLAR MODULES PV -2.0 SITE PLAN • MODULES: (20) REC SOLAR: REC285TP2 BILK ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. RAIL • INVERTER(S): • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC. PV -3.0 LAYOUT (1) NINGBO GINLONG TECHNOLOGIES: SOLIS-5K-2G-US • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. MP MAIN PANEL 0 0— • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV 4.0 ELECTRICAL SEE PEN D01. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. PV -5.0 SIGNAGE 11.4f • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.SP SUB -PANEL STANDOFFS & of heatf Udoe • . INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. FOOTINGS COM�WCity MUNrrYDEwtopmtwT CHIMNEY CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).PV LC LOAD CENTER APPROVED • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.66 AMPS MODULE SHORT CIRCUIT CURRENT. ATTIC VENT Reviewed for Code Compliance • 15.09 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. SM SUNRUN METER FLUSH ATTIC VENT f DEDICATED PV METER o PVC PIPE VENT INVERTER(S) WITH rarMs >�e�ed.eer*wopen INV INTEGRATED DC METAL PIPE VENT �G•w�•f• .�I�soomw•l•uossshoreoteeooa+�t/or, «wgaerwlewir�a go ov� DISCONNECT AND AFCI T -VENT awfifoeaoNik Olt*I IdFgeak.►•f•wpc•padiwwa www ralrrq mwe.Mnar«Nameaaaia+aKaow4. ysuaaa AC ooaes«atie+aa•rwsgweananrw.e�eaw AC DISCONNECT(S) DISH � SATELLITE DC DC DISCONNECT(S) FIRE SETBACKS CB 0 COMBINER BOX HARDSCAPE INTERIOR EQUIPMENT — PL— PROPERTY LINE J SHOWN AS DASHED SCALE: NTS sunrunLE A AMPERE AC ALTERNATING CURRENT AFCI AZIM ARC FAULT CIRCUIT INTERRUPTER AZIMUTH ELECTRICAL CONTRACTOR VICINITYMAP COMP COMPOSITION 6040 WEST 91ST AVENUE, WESTMINSTER, CO 80031 DC (E) DIRECT CURRENT EXISTING PHONE 303.577.6527 FAX 303,577 9629 _ EXT EXTERIOR CUSTOMER RESIDENCE: FIRM FRAMING RANDOLPH LUMPP INT INTERIOR 3680 MILLER WHEAT LBW LOAD BEARING WALL RIDGE, CO, 800033 3 MAG MAGNETIC MSP MAIN SERVICE PANEL TEL (303) 420-1128 APN #:3928102019 _ (N) NEW NTS NOT TO SCALE PROJECT NUMBER: OC ON CENTER 501 R-680LUMP PRE -FAB PRE -FABRICATED DESIGNER: 424.280.7063 36BU Miller Court PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC JORGE JIMENEZ TL TRANSFORMERLESS A nom . C3 TYP TYPICAL DRAFTER: V VOLTS W WATTS SHEET REV NAME DATE COMMENTS °Y""`" COVER SHEET A REV: A 10/25/2017 PAGE PV -1.0 � wheal Ridge H,gh Selml0 SITE PLAN - SCALE = 3/32" = 1'-0" PL PL U Lu J � 7. z (E) DRIVEWAY PL PL PL PL PL =IRE SETBACKS (3' TYP) N) ARRAY AR -01 E) A/C UNIT MP SE 8�HdSMINV (E) RESIDENCE a PL PL PL PL PL PL City of Wheat Ridge Building Division v a J d a a J a PL ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF EXPOSURE FRAME MATERIAL FRAME TYPE FRAME SIZE MAX FRAME SPAN OC SPACING ROOF EDGE ZONE MAX RAIL SPAN MAX RAIL OVERHANG DESIGN CRITERIA MODULES: AR -01 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY ATTIC WOOD RAFTER 2 X 6 9'- 3" 24" N/A 4'- 0" 2'- 0" REC SOLAR: REC285TP2 BLK AR -02 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY ATTIC WOOD RAFTER 2 X 6 9'- 3" 24" N/A 4' - 0" 2'- 0" MODULE DIMS: 65.94" x 39.25" x 1,49" (38mm) D1 - AR -01 - SCALE: 3/16" = V-0" PITCH: 11° AZIM: 90° MODULE CLAMPS: Portrait: 8.2" - 16.4" Landscape: 4.9" - 9.8" MAX DISTRIBUTED LOAD: 3 PSF ® SNOW LOAD: 30 PSF WIND SPEED: 60'-3" 9' 11" —3'— 105 MPH 3 -SEC GUST. _. `��,ro� �> 3 ' LAG SCREWS: NOTE3.5": 2.5" MIN EMBEDMENT INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. r O 11' PENETRATION SPACING: FULLY STAGGERED O— D— TI T 4' TYP— I O- O—.._. —0-1- O _ O _ 53'-8" 16'-6" — 3 �' nr su n u 11 D2 - AR -02 - SCALE: 3/16" = V-0" PITCH: 11 ° 10'-3" AZIM: 270° ® A•"p 6 j fir" / 19'-10" 11'-5" city 01 Wheat Rid9g 3 IV I$IOn � guildln9 D ELECTRICAL CONTRACTOR 6040 WEST 91ST AVENUE, WESTMINSTER, CO 80031 PHONE 303 .6527 FAX 303.57777 96.9629 � �^`� / ,i f ,� ` "4 CUSTOMER RESIDENCE: RANDOLPHLUMPP —4' TYP— 3680 MILLER CT, WHEAT RIDGE, CO, 80033 0 e- - e- o -- o / TEL (303) 420-1128 APN #: 3928102019 —® — 0 0 PROJECT NUMBER: 501 R-680LUMP DESIGNER: 424.280.7063 y JORGE JIMENEZ DRAFTER: �� [l G S�ONA1 � SHEET LAYOUT REV: A 10/25/2017 v r — 3'-4" — 19'-10" 8'-2" Exp. 10-31-2019 PAGE PV -3.0 120/240 VAC SINGLE PHASE SERVICE OMETER #: M XCEL 80560619 UTILITY GRID EXISTING 1 150A MAIN CBREAKER 1 (END FED) EXISTING 150A MAIN FACILITY PANEL LOADS 30A PV -L-GROUND BREAKER AT OPPOSITE END OFBUSBAR (N) LOCKABLE (N) SUN RUN NINGBO GINLONG CONDUCTOR N DEDICATED BLADE TYPE ( ) CENTRON 4G TECHNOLOGIES: SOLIS-5K-2G-US S RSD 2'2 RAPID SHUT DOWN DEVICE, PV KWH METER AC DISCONNECT METER 5000 WATT INVERTER JUNCTION BOX NEMA 4X, 600V NONE (4) 10 AWG PV WIRE OR EQUIVALENT (1) 6 AWG BARE COPPER 5 54 4 .—./. 3 2 (1) 6 AWG BARE COPPER (2) 18 AWG SIGNAL CIRCUIT WITHIN TC -ER _ 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 (2) 14 AWG THHN/THWN-2 SIGNAL CIRCUIT 240V METER SOCKET SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT 0 200A CONTINUOUS DU221 RB 125A CONTINUOUS & WITH AFCI, RAPID SHUTDOWN (2) 6 AWG THHN/THWN-2 WITH LEVER BYPASS 3R, 30A,2P 240V METER COMPLIANT [MAX 10' FROM 120/240VAC 200A, FORM 2S UTILITY METER] [MAX 10' FROM UTILITY METER] [READILY ACCESSIBLE MEANS FOR RAPID SHUT DOWN] CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 0 NONE NONE NONE (1) 6 AWG BARE COPPER 1 NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER (2) 18 AWG SIGNAL CIRCUIT WITHIN TC -ER 3 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 (2) 14 AWG THHN/THWN-2 SIGNAL CIRCUIT 4 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC 5 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: 5700 W SYSTEM OPEN CIRCUIT VOLTAGE: 533 V SYSTEM OPERATING VOLTAGE: 383 V MAX ALLOWABLE DC VOLTAGE: 600 V SYSTEM OPERATING CURRENT: 17.9 A SYSTEM SHORT CIRCUIT CURRENT: 24.15 A MODULE CHARACTERISTICS REC SOLAR: REC285TP2 BILK: 285 W OPEN CIRCUIT VOLTAGE: 38.6 V MAX POWER VOLTAGE: 31.9 V SHORT CIRCUIT CURRENT: 9.66 A PV MODULES 1 REC SOLAR: REC285TP2 BLK +1f (20) MODULES (1) STRING OF (8) MODULES (1) STRING OF (12) MODULES NOTES TO INSTALLER: 1. 463 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. IN MAIN PANEL REPLACE (2) 20A 2P BREAKERS WITH NEW 20/20A 2-2P QUAD BREAKER. 3. ADD 30 AMP PV BREAKER TO MAIN PANEL. 4. CONNECT THE RAPID SHUTDOWN SIGNAL CIRCUIT CONNECTORS PER MANUFACTURER SPECIFICATION. 5. SPLICE THE 14 AWG THHN/THWN-2 CONDUCTORS FOR RAPID SHUTDOWN SIGNAL CIRCUITS INTO 18 AWG CONDUCTORS WITHIN TC -ER CABLE AT THE JUNCTION BOX. City of Wheat Ridge Building Division OWARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2016: 690.17(E), NEC 2014: 690.17(E), NEC 2011: 690.17(4) WARNING ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED \ 1mir•TaY i7M INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2016: 690.31(G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 II_\:1a■KOMW-. Co7k UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2016: 690.12, NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1 �l LABEL LOCATION: LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF INTERCONNECTION. APPLICABLE). PER CODE(S): CEC 2016: 690.54, NEC 2014: 690.54, NEC PER CODE(S): CEC 2016: 690.5(C), NEC 2014: 690.5(C), 2011: 690.54 NEC 2011: 690.5(C) &WARNING ELECTRICAL SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: INVERTER(S), DC DISCONNECTS. PER CODE(S): CEC 2016: 690.35(F), NEC 2014: 690.35(F), NEC 2011: 690.35(F) 0! WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2016: 705.12(D)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(b), NEC 2011. 705.12(D)(7) &WARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2016: 705.12(D)(3), NEC 2014: 705.12(D)(3), NEC 2011: 705.12(D)(4) ,WARNING PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2016: 705.12(D)(2)(3)(c), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) INVERTER 1 I ARFI I nCATInN INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2016:690.53, NEC 2014:690.53, NEC 2011: 690.53 NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN StKVIUL ENTRANCE AND PV BREAKER DISCONNECT INVERTER �LOCATION JOF SUNRUN METER AC DISCONNECT "RAPID SHUTDOWN" 3680 MILLER CT, WHEAT RIDGE, CO, 80033 City of Wheat Ridge BUliding Division SNAPNRACK COMPOSITION L FOOT SNAPNRACK STANDARD RAIL SNAPNRACK C❑MP❑SI ROOF FLAS a' S.S. LAG SCREW ' 2.5' MINIMUM EMBEI SNAPNRACK L FOOT BASE SEAL PENETRA UNDER B( APPROPRIATE ROOF RAFTER TYP, FLASHED L FOOT MOUNTING P❑INT FOR USE ON COMPOSITI❑N ROOF SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3' USING UP TO TWO LEVELING SPACERS AS SHOWN IN 'SERIES 100 RAIL LEVELING' S.S. BOLT AND WASHER >. FLANGE NUT REVISION: NOTES; - 5/16' LAG BOLTS MUST EMBED 2,5' INT❑ ROOF STRUCTURAL MEMBERS/RAFTERS - TORQUE ALL 5/16' HARDWARE TO THE FOLLOWING: - SILVER S.S. 10-16 FT -LBS - BLACK S.S, 7-9 FT -LBS - RAILS CAN MOUNT TO EITHER SIDE OF L FOOT (UPSLOPE VS DOWNSLOPE) STEP 3: PLACE L FOOT ON TOP OF FLASHING AND TIGHTEN NUT STEP 21 SLIP ❑VER LASE :P 1; BOLT L FOOT >E TO ROOF WITH BOLT City of Wheat Ridge -luilding Division TYP, TH[S INFORMATION IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DESIGNER G. McPHEETERS SCALE DNS PART # p E N DETAIL 01 F LAS H E D L FOOT REV DISCLOSURE, OR USE THEREOF IS EXPRESSLY —U s * PROHIBITED WITHOUT THE WRITTEN PERMISSION DRAFTER G. McPHEETERS DATE 120111 PEN—DO1 E OF MAINSTREAM ENERGY CORPORATION. INSPECTION RECORD OccupancV/Tyr ®'INSPECTION LINE: (303) 234 -5933 I Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS J6B FOUNDATION INSPECTIONS DATE INSPECTOR COMMENTS: INITIALS Footings / Caissons Stemwall / (CEG) Concrete _ Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (U Heating (Underground) ROUGHS Sheathing Lath / Wall ti Mid -Roof Electrical Se Rough Elec Rough Pl um bi ng Gas Piping Rough Mechanical Insulation Drywall Screw PRIOR TO FINALS Electrica Plumbing Mechanical Roof Building Final Fire Department R.O:W & Drainage INSPECTIONS FOR PLANNING &ZONING, FIRE AND PUBLICE WORKS Pafl(Ing & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY /S ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR P FOR OCCUPANCY. ABOVE HAS BEEN SIGNED FLOOR UNTIL (lrrlloAKfr� llkll�� ♦ i " CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: A41,,4-Z Job Address: 3680 111i / / <<ic 95�' Permit Number: 6)9',35"-5` ❑ No one available for inspection ,Time cC) AN/PM Re- Inspection required: Yes INo When corrections have been made, call for re- inspect on 303- X933 Date: Oa Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division �r (303) 234 -5933 Inspection line r (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE , Inspection Type: Job Address: q,::, Fzl ��11 /Fe e Permit Number: 0 9 Y3SS No one available for inspection: Time 35 AM/PM Re- inspection required: Y& No When corrections have been made, call for re inspection at 303 - 234 - 5933 Date: Inspector: DO NOT REMOVE THIS NOTICE i Mailing Address: P.O. Box 1296, Englewood, CO 80150 - Physical Address: 4065 S. Eliot St., Englewood, CO 80110 XTER /OR OLL/T /ON5 EXTERIOR MAINTENANCE REDUCTION 303- .789 -7900 July 21 2010 To Whom It May Concern, This payment is for two re- inspection fees for permit number 094355. The address is 3680 Miller Ct. After processing could you please fax me a copy of the receipt to 303 - 789 -5956? Thank You, Nicole Schoeninger Exterior Solutions 303- 789 -7900 CITY OF WHEAT RIDGE 07122/10 1:37 PM edbb Exterior Solutions RECEIPT NO:CDB004883 AMOUNT BPSP Reroof 29 sqs with 5 122.00 094355 Reinspection Fee 61.00 Re -insp fee 2 61.00 PAYMENT RECEIVED AMOUNT GK 2573 122.00 TOTAL 122.00 Mailing Address: P.O. Box 1296, Englewood, CO 80150 - Physical Address: 4065 S. Eliot St., Englewood, CO 80110 i ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: fif -L Ae4 /= Job Address: 3�66O sailla &I Permit Number: 6J7 f°3SS 5 /•am M9 /%N7 - - 4 FwLS ❑ No one available for inspection: Time !+' Y® Awla Re- Inspection required: Ye No "When corrections have been made, cail for re inspection at 303 - 234 - 5933 Date: /p Inspecto DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax Inspection Type:. Job Address: Permit Number: NOTICE 0 Dad; y (Nl �. ° m 1 L3 No one available for inspection: Tie A PM 'rYit Re- Inspection required: Yes No When corrections have been made, can for re ins ( p� p ectio at 303 Date: 7 /3 • t�� Inspector: DO NOT REMOVE THIS NOTICE XTER /OR OLLJT /ONS EXTERIOR MAINTENANCE REDUCTION 303- 789 -7900 June 17, 2010 To Whom It May Concern: These payments are to extend two roofing permits. The check for $81.45, check number 2515, is for permit 094355. The address is 3680 Miller Ct. The second check for $90.55, check number 2514, is for permit number 093269. The address on the home is 3955 Allison St. if you have any questions please - - feel free to give me a call. Thank you, Nicole Schoeninger Exterior Solutions 303- 789 -7900 CITY OF WHEAT RIDGE 06/18/18 2:50 PM cdba CITY OF WHEAT RIDGE Exterior Solutions 06/18/18 2:52 PM cdba RECEIPT HO:CDA004553 AMOUNT Exterior Solutions BPSP Reroof 29 sqs with 5 81.45 094355 RECEIPT NO:CDA004554 AMOUNT Extend Expired Peroi 81.45 RPSP Reroof 26 sqs 90.55 893269 PAYMENT RECEIVED AMOUNT Extend Expired Peroi 98.55 - - CK 2515 TOTAL 81.45 81.45 PAYMENT RECEIVED AMOUNT -- -- - ----------------------- - - -- --- CK 2514 98.55 TOTAL 98.55 C1CJ�124,9 _ C� IG�Qd Mailing Address: P.O. Box 1296, Englewood, CO 80150 Physical Address: 4065 S. Eliot St., Englewood, CO 80110 ♦ 4' CITY OF WHEAT RIDGE B uilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: �wloAwF Job Address: govz?,9 IwIlk-ak C7 Permit Number: t9�7 -7 r_Q ❑ No one available for inspection: Time V,10 AMkw Re-Inspection required: Yes When corrections have been made, call for re-inspection at 303-2345933 Date: f22 Inspector: DO NOT REMOVE THIS NOTICE 14 ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax i INSPECTION NOTICE Inspection Type: g:;~E, Zg4~ Job Address: 36~8a r lull/! c-7 Permit Number: b9Y,Vy~ No one available for inspection: Time ~S AM/10R)_ Re-Inspection required: YesC-Nod ' When corrections have been made, call for re~-inspection at 303-234-5933 Date: a S ~a Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE ~-j Bung Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax IN~SPE~C`TION NOTICE Inspection Type: I'\rO f Job Address: 3690 011'/ fil Permit Number: larjgy,-7-7 P1~ ~Pk"bth!i~ ~afQG~-£1hfi~ iYP~ v`•P ~~ji~rcg~i (be-, r'r e -Q! tAPYJ 7 r11 P t r/`~ l~ Relf~nFlP fn bF ~tv£h 04 c6141Vere~`<r fa~'FA)IrP IP-LGt~~~t!l ~tY, ~ C'i Ek if-F.~I! :t)~'rF ~N..v r_n"~r _ ?fbRrLt C _VMV/Ptr lehet If - 1,1 =d 4` f,C~t,s?IFIt t lcrr, P(%~'r, Frt Y-- Er~~7✓7'd~ Yz +SC7 Lrl,!',t t QY P- FXr F?~, t~1s I cell ~r ~%r`8'`t ❑ No one available for inspection: Time AMI~,M Re-Inspection required: es No *When corrections have been made, call fiff7resp7etl07 " at 303-234-5933 Date: Inspec DO NOT REMOVE THIS NOTICE ~oF""~9?qd City of Wheat Ridge Building Division m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 ` Fax: 303-235-2857 Inspection Line: 303-234-5933 O(ORPO Building Permit Application PropertyrAddress: 3L 13 AJ( L-, G+ Property Owner (please print): Mailing Address: (if different than property address) Address: Date: Plan Permit # Phone: 4 - ~ - /J:1-r City, State, Zip: Cgrifractor:~7 Contractor License Phone:303--789- 7900 Stit`Co.4tractor$c Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction Value: $ .5: 2 Daschptlon dJ wo k': hZ[ M q(~( gp (as calculated per the Btritdinq aluation Data sheet) 5 DY 1` ~tsPl~ Rra-- 5L.'r~GS Plan Review (due at time of submittal): S Sq. Ft./L.Ft added: Squares 91 BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances. rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (O NER)^ (CONTRACTOR) or PERSONAL REPRE~SgNTA`TIVE of( Vt(0 R) (CONTRATOR) / PRINTNAME: -Sp4(CS SIGNA4,o,. ZONING COMMENTSi DEPARTMENT USE ONLY - > > 9fOni I ~ r k~~kt 3v ~ 3,14 Y`~)r~~rr ifi r`~~; 1 Ir ~ ~ h y X a'"~✓ct kr~T~ k~l~ ~j~r:n sk" r v1Y4vya ar ly > ' * at3 M gg .yf zl .M4^t ~ iii ft'l r lrr r i ~ ^ ~ r f T ~ 1 BU1LpING EP Y drf"a~x e n.g e• y y i r X gagQ „¢AB.TME,~NT GOM~MEN75~ S~av T „ ~ y , X , -t `~~OCCUPANCY '?r+.`GeXfZe~leY+BP'~j>~~„~.,:~ h'WkX %hi ° W `x .~''~P w yti"r rra ~ + ~ i i t ~ 3` ttlrt r~ ~qmn . S~yy,, xrv ~~p~J~~./i .u^'~~'~xhra rR v~XbA ,(~J~4.r o~,~ p r ~s t r r_•'7'y ~ n:, xr.. AYf:4 11 b w 5{reX d).. a~.W(NNI p~Y'~ l:: h z a i~Ip-- k Sr V'~ i e ,....C FIRE DEPARrTJ.t N7,, Dapproved w/eomrge~ts~r O,.tlfsapprpved pno ievlew regyX[ed- Bidg Vaiuation:E City of Wheat Ridge .r l Residential Roofing PERMIT - 092968 PERMIT NO:. 092968.. : ISSUED:.. ..10/05/2009 JOB.. ADDRESS: .3680. MILLER CT EXPIRES: -:04/03/2010 DESCRIPTION:. Reroof 32 sqs CONTACTS.***. owner 720/231-7330 Randolph Lumpp sub 888/378--1051 Clifton :Smith ,.09-0387 LJA Commercial Solutions PARCEL INFO ZONE; CODE: UA - USE: UA SUBDIVISION:. 0638. .:BLOCK/LOT#: 0/ **'FEE SUMMARY -.ESTIMATED. PROJECT' VALUATION: 6,500.00- FEES Permit Fee 181.10 T%~~~ l~ Total Valuation ,00 r 1,. Use Tax .:117.00 TOTAL 298.10 Conditions:' 6 nail installation & mid-roof inspection required. Board sheathing spaced more than .'a 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield required from eave edge to 2' inside exterior walls. Subject to field inspection. I hereby certify.. that the setback. distances proposed by this permit application are accurate, and do not violate applicable ordinances, 'rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record;. that all measurements 'shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that i. assume full. responsibility for compliance with the Wheat: Ridge Building Code-.(I.B.C) andall other ' applicable wheat Ridge , Ordinances, for. work under this. permit. Plans subject to field inspection. signatYL-~of contractor/owner date L This permit was issued in accordance with the provisions. set forth in your application and is subject to the , laws of the state of Colorado and to the zoning Regulations and :Building Codes of Wheat: Ridge,' Colorado or any, other. applicable ordinances of ' the City. ? This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date An extension maybe granted`. at the discretion of the Building Official. 3. If this permit. expires,r a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one ;(I) year. If changes: have been or if suspension or abandonment.' exceeds one (1) year, full fees :shall be paid for a-hew permit. k. No. work of any. manner shall be done that will change the natural flow of water causing a. drainage. problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for. all. inspections and shall receive written approval on inspection card. before proceeding with successive phases of the job:. The issuance. of a permit or the approval of drawings and specifications shall not be :construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law,:. rule or regulation. All plan review is subject to field. inspections. n A. Signature Bur lding Official -date CNSPEC MON U EST LINE: (303)234-5933 BUILDINGOFFICE (303)235-2855 2EQUES SMUST BE MADE BY 3PM'ANY 3USINESS. DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. F W"E?Tq City of Wheat Ridge Building Division ( , m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 o~<oaroo Inspection Line: 303-234-5933 Propert y Address: Property Owner (plee Mailing Address: (if different than property address) Address Date: Plan Permit City, State, Zip: Contractor: Contractor License Phone: Stib Contractors; Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. _Date: Exp. Date: Exp. Date: Use of space (description): Construction Value: $ /y\ OD Description of,workc L' Jy - (as calculated per the Building Vatualion Dafa shee ) A % Plan Review (due at time of submittal): $ Sq. Ft./L.Ft added: Square BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE: ,(OWNER) (CONTRACTOR) or PERSONAL REPRESENTATI E of ER) KONTRATOR) PRINT NAME: (m~4aoo~ L SIGNATUR Date: / 1-5 -09 / Bldg Valuation: $ Building Permit Application