HomeMy WebLinkAbout4075 Miller CourtSCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 711 UW DC, 5220W AC • ALL WORK SHALL COMPLY WITH 20181RC/IBCIIEBC, MUNICIPAL CODE, AND ALL SOLAR MODULES W-1.0 COVER SHEET • MODULES: (18) LG ELECTRONICS: LG39501C-M MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SE SERVICE ENTRANCE PV -2.0 SITE PLAN • INVERTERS: (18) ENPHASE ENERGY: IWPLUS-M-2-US • PHOTOVOLTAIC SYSTEM MILL COMPLY NTH NEC 2020. • RACKING: SNAPNRACK RLU; RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC60436 • ELECTRICAL SYSTEM GROUNDING WILL COMPLY NTH NEC 2020.MP MAIN PANEL PV -3.0 LAYOUT PV -3.1 MOUNTING DETAIL ..� • PHOTOVOLTAIC SYSTEM IS UNGROUNDED, NO CONDUCTORS ARE SOLIDLY SNR MOUNT / Wheat d � GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 890.35. SP SUB PANEL SNR MOUNT S SKIRT P114.0 ELECTRICAL PV -5.0 SIGNAGE oe Y COMMUNITY D[vuorw� • MODULES CONFORM TO AND ARE LISTED UNDER UL 170M1730 APPROVEDLC PV LOAD CENTER ® CHIMNEY • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. Revawedfar Code Co Iia/nce • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.SUNRUN SM METER 0 ATTIC VENT /Z ,21 • SNAPNRACK RACKING SYSTEMS, IN COMBINATION NTH TYPE I, OR TYPE II 0 FLUSH ATTIC VENT Plan, Examiner Date MODULES, ARE CLASS A FIRE RATED.PM DEDICATEDPVMETER wee a tMnre ysxmweaypww°]em,.wo<JlwnoM PVC PIPE VENT RAPID°"em.wroroM,n,v„wm°e��eM.>+roawa°/°M.°°ewm REQUIREMENTS METMENALL INVERTPER a,wAe umuww°n eewmmss,. TORS E CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). CONDUCTORS NEC INV INVERTER(S) ® METAL PIPE VENT peumry SO 9" outXalry I° wNMwwml rMpmvm, aIMiNMYq P`x "SO 9"olww Baw; ® T -VENT '°a^°'O'^^°�^°^'_°/'^•r^+=^°°'^I^•w^4 • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC 0i AC DISCONNECTS) SATELLITE •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DISH •11.29 AMPS MODULE SHORT CIRCUIT CURRENT. O DC DISCONNECT(S) � FIRE SETBACKS • 17,64 AMPS DERATED SHORT CIRCUIT CURRENT [690.6 (a) 8 690.8 (b)]. •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(8)(2). CB IQ COMBINER BOX _ HARDSCAPE CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDONM INITIATION r, INTERIOR EQUIPMENT —PL— PROPERTY LINE A qualified person must be present at the time of a PV electrical inspection LJ SHOWN AS DASHED SCALE: NTS 1) Licensed master or journeyman electrician, sunrun A AMPERE AC ALTERNATING CURRENT 2) Residential wireman AFCI AZIM ARC FAULT CIRCUIT INTERRUPTER AZIMUTH VICINITY MAP 3)NABCEP-certified solar installer capable of testing the rapid shut down system. COMP COMPOSITION EC#]080,ME#600088 DC DIRECT CURRENT »'+=^a+•• wa°9'"a (E) ESS EXISTING ENERGY STORAGE SYSTEM Exs wmwAVE. MWAogcoamf Pao Eew°' Ml J r B e - '14 n EXT EXTERIOR CUSTOMER RESIDENCE: rAxu n �� INT INTERIOR eras A,.,acoro - <..nNue Mau-oenreQ - '"` MAG MAGNETIC ERIN HOWARD MSP MAIN SERVICE PANEL 4075 MILLER CT, WHEAT RIDGE, (N) NEW CO, 80033 MANSflean $ di-vNC In i NTS NOT TO SCALE / OC ON CENTER TELI307I631-1828 w -n_OM:dssage �orMre PRE -FAB PRE -FABRICATED MN: 491W �R° UNG xcioHrs —,II PSF PV POUNDS PER SQUARE FOOT PROJECT NUMBER: v r I,n PHOTOVOLTAIC _ll _ Ows Mxf' ya. 8�-� U N ,7~ •Pi°0`.dca1"e;as? ##A RSD RAPID SHUTDOWN DEVICE 501 R-0]SHOWA e TL TRANSFORMERLESS DESIGNER: (415) 5606820 ex3 r 61 TYP TYPICAL aL ;w AcewooO NEW Tuna renaumm - Nes V VOLTS DUSTIN BUYER ViLuees t . nm" W WATTS SHEET 6b- COVER SHEET REV NAME DATE COMMENTS ..,m —. 1 r REV:A 12/212021 - �Veg ww.., .Eroa... *6010e" - PAGE _ s>�-�;i PV -1.0 SITE PLAN -SCALE • 3135' • 1' F PL PL PL ROOF PATHWAYS (N) ARRAY AR -04 tPLd dtlr PLv� PL T NOTES: • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: IIII�IIII�yIIII • TOTAL ROOF SURFACEAREA SO F SOFT. I I g • TOTAL PV ARRAY AREA: AGE SO FT. • PERCENTAGE A COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) '100=19.6% (E) DECK • g (N) ARRAY AR43 (N)ARRAY AR -M FIRE SETBACKS (ta° TYP) • ROOF PATHWAYS g IT TYP) LPL PL PL PL PPL PL PL (E)RESIDENCE (N)ARMY AR -01 (E) GATE NOTE: MICRO -INVERTERS INSTALLED UNDER EACH MODULE ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portmit MAX DISTRIBUTED LOAD: 3 PSE Name Type HeightType Span Spacing Detail OC Sparing Overhang OC Spacing Overhang COnBguralion SNOW LOAD: 30 PSF RL UNIVERSAL, SPEEDSEAL TACK ON WIND SPEED: AR41 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 24" 6'-0" 2'-4" 4'-0' 1'-10" STAGGERED iW MPH&SEC GUST. 11" COMP, SEE DETAIL SNR-DC-00436 S.S. LAG SCREWS: AR42 COMPSHINGLE-RLU 1-Story 2X6 RAFTERS 12'-3" 24" RL UNIVERSAL, SPEEDSEAL TPACK ON COMP, SEE 6'-0" 2'-4" 4'-0' 1'-10" STAGGERED `'X13'2'5"MIN EMBEDMENT STRUCTURAL NOTES: DETAILSHR-DC-00636 • INSTALLERS SALL NOTIFY AR43 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 12'-3" 24" RL UNIVERSAL SPEEDSEAL TRACK ON COMP,SEE -0" 2'-4" 4'-0' 1'-10" STAGGERED ENGINEER OF ANY POTENTIA DETAIL SNR-DC-006362P STRUCTURAL ISSUES AR-04 COMPSHINGLE-RLU 1-Story 2X6 AFTERS 12'-4" 24" RL UNIVERSAL SPEEDSEAL TRACK ON COMP,SEE 6'-0" 2'-4" 4'-0' 1'-10" STAGGERED OBSERVED PRIOR TO DETAIL SNR-DC-00636 PROCEEDING W/ INSTALLATION. D1-AR-0I-SCALE: 3/1S"•1'-0" D2-AR-02-SCALE: 1/8"=1'-0" AZIM:270' • IF ARAV(EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY AZIM:1800 PRCEI B'-3" 5'-9"— 12' PITCEIIO° REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS)13'!r—"Z��\ 18'6"— CL;ft THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANREDUCED VVRHINTHE I2" BOUNDARY REGION ONLY AS FOLLOWS: •• ALLOWABLE ATTACHMENT D SPACING INDICATED EON PLANS TO BE REDUCED BY D All, All, 50% IN, ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 8 11 —8 TYP 1/511-1 OF ALLOWABLE O ATTACHMENTS ACING INDICATED ON PLANS ' 6' TVP.— L8.. sunrun D3 -AR-03 - SCALE: 118" • 1'4" 04 -AR-04 - SCALE: WIV' • 1'4" Al EC #7080, ME 1161)0088 AZIM:900 PRCEI PITCH:19°51rvtloi "Ir ❑CFy ncncomm —5'-9"— —9'-11'— OQpDO Mwugr/,9 JFo 006 WANT " `11x. �4 an CUSTOMER RESIDENCE: 0056164 ERIN HOWARD 1,-511 4075 MILLER CT WHEAT RIDGE, 111'-2" 90,t. CIVIL ��'r CO, 811033 FSS/ONPL�C'\ TEL (491)831-1828 E+P. 10131/2023 N: qp69186 T16-TYP.—T PROJECT NUMBER: All 501R-075HOWA 6'TYP. DESIGNER: (415) 5806820 ex3 DUSTIN BOYER 6" SHEET LAYOUT REV:A 1221/2021 PAGE PV-3.0 SEE SITE PLAN FOR NORTH ARROW SNAPNRACK RL UNIVERSAL SPEEDSEAL TRACK COMPOSITION R( EN ST FC REVISION. L MOUNTING DETAIL REV:A 72R1I2027 PV-3.1 -LYp DESIGNER D.RYAN JOnLt' PAR rvUNBtIt IIIN//' V NTS V\\VII �bNnrunwTM DRAFTER'. B.PETERSON SNR -DC -0 m APPROVED BY: W.ARBUCKLE DATE: inrzo2o MOUNTING DETAIL REV:A 72R1I2027 PV-3.1 OPPOSITE END OF BUSBAR CONDUITSCHEDULE # Approval Notes: SINGLE vnc NEUTRAL 1) PN array system to have grounding system installed per Part III of SINGLE PHASE NONE (2) 12 AWG PER ENPHASE O SERVICE (1) 10 AWG BARE COPPER Article 250 per 2020 NEC Article 690.47(A). 2) If LIFER ground in not available provide or verify supplemental OXCEL METER a: 87957599 ground rods per 2020 NEC Article 250.53(A)(3). 2 3/4"EMTOREOUIV. 3) Cold Water & Natural Gas bonding per 2020 NEC Article 250.104(A)&(B) NONE EXISTING ( 200A MAIN BREAKER (N)125A ENPHASE 10 .� J f (18) LG ELECTRONICS: 1 (END FED) EXISTING AC COMBINER BOX �ff �fJ f MICRO -I VER MODULES AND WITVOYSRINTEGRATED lJJ MICRO -INVERTER PAIRS 10A ENVOY BREAKER ti (1) 10 AWG THHN?HWN-2 (1) 8 AWG THHNrrHWN-2 3CX-10-AMf-240-3C (16)ENPHASE MAIN &n.2 -ENERGY: I0]PLUS72-2-US ~ ~ PANEL 3 JIINEQUIVA OX 2 OR EpNIVALENT 1 �' a OF MICBRANCH VERTER) RTERS [A] RANCH !! (1) RAN OF MIC VERTE S MICRO -INVERTERS [B] 20A BREAKER (A] (N) 30A PV BREAKER ATo 20A BREAKER [B] OPPOSITE END OF BUSBAR CONDUITSCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE O NONE (1) 10 AWG BARE COPPER CABLE BRANCH 2 3/4"EMTOREOUIV. (2) 12 AWG PER ENPHASE O NONE (1) 8 AWG THHNrrHWN-2 CABLE BRANCH EGC/GEC 3 3/4"EMTOREOUIV. (2) 10 AWG THHNrrHWTi2 (1) 10 AWG THHN?HWN-2 (1) 8 AWG THHNrrHWN-2 EGC/GEC MODULE CHARACTERISTICS LG ELECTRONICS: LG395010-AS: 395 W OPEN CIRCUIT VOLTAGE: 43.6 V MAX POWER VOLTAGE: 37 V SHORT CIRCUIT CURRENT: 1129A QI WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON UNE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITM LABEL LOCATION: INVERTER(S). ACIDC DISCONNECT(S), AC COMBINER PANEL IIF APPLICABLE). PER OODECR: NEC 2020:660.13SR nWARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM PER OODE(S). NEC 2020705.12(C) Qf WARNING POWER SOURCE OUTPUT CONNECTIO N DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER AND ESB OCPD (IF APPLICABLE). PER CODEI$)'. NEC 2020'. 705 12(B)(3)(2) Q! WARNI PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS LABEL LOCATION: PHOTOVOLTAIC AC COMBINER BF APPLICABLE). PER CODE(S): NEC 2020: 705.12(D)(2)(3)(c) LABEL LOCATION'. AO DISCONNEOT(6), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODOS): NEC 2020'. 69054 LABEL LOCATION'. INSTALLED WITHIN 3OF RAPID SHUT DOM SNATCH PER DORRIS): NEC 2020:660.56(CX2),LPC 2012:605.11.1, IFC 2016:1204.5.3 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPIDSHUTDOWN SWRCHTOTHE^OFF" POSIHON TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. g LABEL LOCATION: ON OR NO MORE THAT 1 M 13 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S) NEC 2020:690.56(C) NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE MEG 2020 ARTICLE 110.21 RN, UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION ON, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE WAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.0.2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. •DO NOT COVER MISTING MANUFACTURER LABELS. CAUTION MULTIPLE SOURCES OF POWER \i SOLAR PANELS AND MICROINVERTERS ON ROOF IQ COMBINER BOX SERVICE ENTRANCE AND PV BREAKER DISCONNECT 4075 MILLER CT, WHEAT RIDGE, CO, 80033 PER CODE(S): NEC 2020: 705.10,710.10 LG395Q1C-A6 395W LG NeON® R is powerful solar module that provides world-class performance. A new cell structure that eliminates electrodes on the front maximizes the utilization of light and enhances reliability LG NeONO R Is a result of Li efforts to increase customer's values beyond efficiency LG NeONa R features enhanced durabilRg performance under real-world conditions, an enhanced warranty and aesthetic design suitable for rooks. C UL US Features � Roof AezMetia LG NeW R has been designed with aesthetics In mina: the hick of any electrodes on the front creates an improved, modern aesthetic Enhanced Performance Warranty The W Nei R has an enhanced performance warranty. After 25 years, LG NeON® R is guaranteed at least 91 of initial performance. m Alt ® 25 -Year limited Product Warranty The Nei R Is covered by 25- year 0ofd prwarrantyduwarnty In addition, up to $as5s of labor costs will be covered in the rare case that a module needs to be repaired or replaced. ® More generation per square meter The LG Nit R has been designed W significantly enhance in output, making it efficient even In limited space. When you go solar, ask for the brand you can trust: LG Solar Mout LIG Electronics; to a..w � .. M ion tee, m. LG ewe.. ode��.w�� m�55A,r1 Iv .o p• • nww None(p m. Ttoaa. The *� Moni room Wei novel a,ws lifers Good LG NeON®R 1Q395Q1C-A6 Ca"ca[ians and Wammy TempwdItumCharal level 44 ± 3 1 ape unl 4)24 @unl 004 m 40 -IBS � ,C m 1,100 By Teel 370 IN &57 1790.1,120.1227 m 414 TempwdItumCharal level 44 ± 3 1 ape unl 4)24 @unl 004 i(exe,so led Im 200 250 200 310 4" IS;a Eieanoi a,opntia(W.) deal m 40 -IBS � ,C m 1,100 By Pen 370 IN &57 1790.1,120.1227 m 414 And IN 910 i(exe,so led Im 200 250 200 310 4" IS;a Eieanoi a,opntia(W.) deal m 40 -IBS � ,C m 1,100 By Pen 370 0,g„w, ,m..ple,IIAQ� mmar.a 1790.1,120.1227 m And all Oma onn Cmdmons mmMieo mnu zmen,.cmenoasn msmm'rxo(niimau.��a�eamme PoGaging Cmrflgu2tian m 40 -IBS � ,C m 1,100 By ISO 0,g„w, ,m..ple,IIAQ� mmar.a 1790.1,120.1227 705.441.4403 mmMieo mnu zmen,.cmenoasn msmm'rxo(niimau.��a�eamme PoGaging Cmrflgu2tian Cinmsions (mmlrch) bn_ m.e..s. . h See �n � ,C NAI ISO By ISO 0,g„w, ,m..ple,IIAQ� mmar.a 1790.1,120.1227 705.441.4403 all Cinmsions (mmlrch) bn_ m.e..s. . h See �n � ,C ®LG m . ws6n„ 0,g„w, ,m..ple,IIAQ� mmar.a Data Sheet Enphase Microinverters Region AMERICAS Enphase IQ 7 and IQ 7+ Microinverters The high-powered smart grid -ready Enphase IQ 7 Micro'" and Enphase IQ 7+Micro" dramatically simplify the installation process while achieving the highest system efficiency Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase Enlighten" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved, lighter two wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-celli halfcelland 72- cell/144 half -cell modules More than a million hours of testing Class 11 double -insulated enclosure OIL listed Smart Grid Ready • Complies with advanced grid support voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (OIL 1741 -SA) ® ' The IQ H Micro is required to To learn more about Enphase offerings, visit enphase.com � ENPHASE Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DO) IQ7-60-2-US 107PLUS-72-2-US Commonly used module palnngis 235W-35OW+ 235W-44OW+ Module compatibility 60 c haltcellPV modules 60-cell/120 half -cell and 72 - 249 VA only cell/144 halfcellPV modules Maximum Input OC vohags 48V 60V QYIS Peak powerlacking voltage 27V -37V 27V 45V OperaMin/Max 16 -48V 16 -60V " in/M xstangerty Max 22V/48V 22V 22V 22V/60V Max DCshort Circuit current (module lsc) DC short circuit 15A !-cl 139 A(208 V) II 11 II SHE Wi8arge ackbees urpurl DC port bacMeetl current 68 His OA PV array configuration Ix l ungrounded array; No edtltlicnal OR Sltle protection regWretl; OUTPUT DATA (AC) IQ 7 Microinverter 10 T+ Microinverter Peak output power 250 VA MC4(or Appointed H4 UTX MI additional Q -DCC -5 adapter) 295 VA 212 mm x 175 mm x 302 man (without bracket) Maximum continuous output power 249 VA Coaling 290 VA Approved for wet locations Nominal (L-L)voltage/range' 240 V/ 208V/ 240V/ 208V/ Environmentalcategory/UV exposure reUng 211-264V 183-229V 211-264V 18&22oV Maximum continuous output current l-0 A(240 V) 1,15A(208 V) 121 A(240 V) 139 A(208 V) Nominal frequency 60 no 68 His Extended frequency range 47-68 Hz 47-68 To AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(IT Q branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltsge class AC port III III AC port backmed current 18 mA 18 mA Power factor setting 1.0 1.0 Power taprior (apit ustable) 0.85leading..0 851agging 0 85 leading..0 85 lagging EFFICIENCY @240V @208V @240V @208V Peak efficiency 91 9].6% 97,5% 97.3% CEC weighted efficiency 97.0% 970% 970% 97,0% Ambient temperature range -4wC to+6SAC Relative humidity range 4% to 100% (condensing) CCnnectortype MC4(or Appointed H4 UTX MI additional Q -DCC -5 adapter) Dimensions(HxWxDS 212 mm x 175 mm x 302 man (without bracket) Weight 108 an (2 3816a) Coaling Natural convection Robins Approved for wet locations Yes Pollution degree PD3 Enclosure Class 11 double insulated, corrosion resistant polymeric enclosure Environmentalcategory/UV exposure reUng NEMA Type 6/outdoor FEATURES Monitoring Enlighten Manager and MyEnlighlen monitoring options. Both options require installation of an Enfilade IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by Eforuss as the load -break disconnect required by NEC 690. Compliance CA Rule 21 SUIT 1741Bad OL 621091, OL1741/IEEE1547, FCC Part 15 Class B, ICES0002Class IF CAN/CBA-C22 2 N0.1071 Ol This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2914, BE 2017, and NEC 2020 section 69012 and C221 2015 Rule 64 218 Rapid Shutdown of Pal System for AC and OC conductors, when installed according manufacturer 'sinstructions - I No enforced Di rasa See the compeaddi barrister at 2. Namesl vocareemere can be extekedbeyond no nal 6 net red by the utility 3. Limps may vary Refer to local requirements to define thenumber of reimoerates per branch In your area. To learn more about Enphase offerings, vises enphase.com v ENPHASE. 02020 inche=s Enemy All nghdr,owned announce, the Fnplowehas borrow IQ 7, Fences 10 71 Sunni 10111 Enpna¢eEnlighten. Fnothwe lQ Emoy, and mean tmaenana or seMcenamps are the tmdendem of Fnambe Exams lrcpne euNw+ to range 202Dua12 Data Sheet Enphase Networking Enphase IQ Combiner 3C (ki(Q-AM1-240-31C) 4L Too learn more about Enphase offerings, visit enphase.com The Enphase IQ Combiner 3Cs' with Enphase IQ Envoy'" and integrated LTE -M cell modem with 5 -year data plan consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre- wired solution for residential applications. It offers up to four 2 -pole input circuits and Eaton BR series busbar assembly. Smart • Includes lq Envoy for ommunication and control • Includes LTE -M cell modem and 5 -year data plan • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2 -pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMAtype 311 enclosure • Five-year warranty • UL listed 0 ENPHASE Enphase IQ Combiner 3C MODEL NUMBER IQ Combiner 30 X-IQ-AM1-240-3C IQ Combiner 3C with Furnace IQ Envo production metering (ANSI Cl2 20a/ - cellular service Consumption Monitoring- CT CT -200 -SPLIT Split corecurrent transformers enable whole home consumption metering bit -2.5%). Circuit Breakers Supporta Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2 240 Circuit breaker. 2 pole, 10A. Eaton BR210 BRK 15A2 240 Circuit breaker, 2 pole, 1 SA, Eaton BR215 BRK-20A-2E 240 Circuit breaker, 2 pole, 201 Eaton BR220 SALE 01 Power line border bomm nication bridge pair), quantity XA PLUG 9203 Accessory receptacle for Power Line Carrier in IQ Combiner 3C (required for EPLC 01) XA ENV-PCBA3 Replacement IQ Envoy huidred circuit board(PCB) for Combiner 3C ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC 60 Hz Eaton BR series Lumbar rel 125 A Max. continuous current rating (output grid) 65A Max. fuse/circuit rating (output) 90A Branch circuits (solar and/or storage) Up to four pole Eaton BE series Distributed Generation(DG) breakers only (not included) Max. command current rating (input from PV) 64A Max total branch circuit breaker rating (input) BOA of distributed generatIon/ 90A with to Envoy breaker included Production Metering CT 200 A solid core prb nstallel and wired to lQ Envoy MECHANICAL DATA Dimensions(WxHxD) 37..Sx49.5xl6.8nm(1475'x19.5'x663").Height is 2106'(53.5 em) with mounting brackets. Weight 7.5 kg (16.51bs) Ambient temperature range -401CIo+461C(,a01tz1H1F) Cooling Natural mormection, plus beat shield Enclosure environmental rating Outdoor,NRTL-certified, NEMA type 3R, polycarbonate Construction Wire sizes . 20 A W AU A breaker imputs: tato 4AWG copper conductors • 60A breaker branch input: 4 to VO AWG copper conductors • Main lug combined output: 10 to 2/O AWC copper conductors • Neutral and ground', alto 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6.560 feet) INTERNET CONNECTION OPTIONS Integrated VA -Fl 802.11moun Ethernet Optional, 802 3, Cat5E(or Cat S) UTP Ethernet cable (not included) Cellular Optional. CELLMODEM 01(3G) or CELLMODEM-03(4G) or CELLMODEM-Ml(4G based LTEM) (not included) COMPLIANCE Compliance, Combiner UL 1741 CAN/CSA C222 No. 107.1 47 CFR, Part 15, Class K ICES 003 Production metering: ANSI C12 20 accuracy class LIS (PV pductlon) Compliance, IQ Envoy UL 60601.1/CANCSA 22 2 No. 610109 1 Consumption mon Poring is required for Enphase Storage Systems. air a To learn more about Enphase offerings, visit enphase.com 4 ®2019 Create Energy AIIdgMnmerver At tratlenurk5 cr brei this document are registered by their immune, moue e- q A 2019-0531 9a.LJ IMV EV projects@evengineersnet.com � ENGINEERS http://www.evengineersnet.com 12/22/2021 RE: Structural Certification for Installation of Residential Solar ERIN HOWARDA076 MILLER R, WHEAT RIDGE, CO 80033 Attn: To Whom It May Concern 276-220-0064 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composite shingle roofing over roof plywood supported by 2X6 Rafters at 24 inches. The slope of the roof was approximated to be 19 degrees. After review and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the Imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SLID is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. Code 2018 International Residential Code(A$CE 7-16) Risk category pppp0 pig NWNeySFO II Wind Load Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. (component and Cladding) V 107 mph Exposure C LICpN Sincerely, pppp0 pig NWNeySFO C Vincent Mwumvaneza, P.E. ppssiaa EV Engineering. g & LLC s.� '0e Proiectstmeyeneineersnet.com s/aNPIE http://www.eveneineersnet.com EXP:10/31/2023 (component and Cladding) V 107 mph Exposure C =- EV projects@evengineersnetmm w� ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation Date: 12/22/2021 Job Address:'AMVMWR CT WHEAT RIDGE, CO 80033 Job Name: ERIN HOWARD ad 276-220-0064 Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet Cover Attachment checks Snow and Roof Framing Check Seismic Check and Scope of work Engineering Calculations Summary Code 2018 International Residential Code (ASCE J-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Uve Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V 10] mph Exposure C 2 NDS for Wood Construction V �pMWaq qi~�n� CITY er Sincerely, nn5616C 4`C �O CMI 1 Vincent Mwumvaneza, P.E. �'sr4RpIHC'v EV Engineering, LLC Proiects(aleyeneineersnetcom E%P:10/31/2023 http://www.evengineersnet.com =- EV projects@evengineersnet.com 276-220-0064 � ENGINEERS hftp://www.evengineersnet.com Wind Load Cant. Risk Category= II Wind Speed (3s gust), V= mph ASCE 7-16 Figure 26.5-16 Exposure = Kn= 1.0 ASCE 7-16 Sec 26.8.2 K,=- ASCE 7-16 Table 26.10-1 Ku= 0.85 ASCE 7-16 Table 26.6-1 Ke= 1.00 ASCE 7-16 Table 26.9-1 cli 0.00256K,K,rKaK,V7= 21.14 psf Pitch =k11 Degrees YE=Conservatively assuming all exposed Y,conservatively assuming 10 ft2 effective area y Ips' (w) zonaiize) zona(2r, 2n) Zone(30) aonel3r) Fig. 30-3-2 GCS -1.1 -2 -2 -2.4 E9. Z9.4-7 P=9n(GCp)(yE)IY,)= -27.90 -50]3 -50.73 -60.88 GCp 0.5 Figure 30.3-2 P=tlh(GC,)(YF)(Y,)= 12.68 Equation 29.4-7 Rafter Attachments: 0.6Da0.6W (CD=1.61 Connection Check Attachement max. spacing= ft 2 66 lbs/in Table 12.2A -NDS Lag Screw Penetration 2.5 in DFLAssumed Prying Coefficient 1.4 Allowable Capacity= 76016s Zone Trib Width Area (ft) Uplift(Ibs) Down(Ibs) Zone(1,3e) 6 19.5 271.2 229.4 Zone(zr, Zn) 6 9.8 235.7 229.4 �aF Zonel3e) 6 9.8 235.7 229.4 Zone(3r) 6 9.8 280.3 229.4 Conservative Max- 280.3 < 760 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind upliftgoverns 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. =V EV projects@evengineersnet.com � ENGINEERS http;//www.evengineersnet.com . ".., -30 74 pIf C, Mdo, pg=.,. psf Mallowable = Sx x Fb'(wind)= 1357 lb -ft > C, = 0.9 Load Case: DL+S F, = 900 psi C, = 1.1 67 pIf 1.0 Mdo I, = 1.0 0.85 Mallowable = Sx x Fb'(wind)= 975 lbft> pr= 21 psf N/A N/A pftm.= 30.0 psf 2.88 Max Moment, M,=wL°/8= 986 lb -ft p,= 30 psf CS= 0.9 51 nit Max Length, L = Shear= 229.4lbs 1.0 able Span) Tributary Width, WT= N/AA 24 in 456 lb Dr= Member Capacity 10 psf 20 pit PVDL= N/A 3 psf 6 pIf Load Case: UL .7 [0.6W+S 0.751Pnet+Psi+Pmcos(B)+Por= 74 pIf C, Mdo, 102316 -ft C, Mallowable = Sx x Fb'(wind)= 1357 lb -ft > 1023 lb -ft OK Load Case: DL+S F, = 900 psi Ps+Pecos(B)+Po,= 67 pIf 1.0 Mdo 921 lb -ft 0.85 Mallowable = Sx x Fb'(wind)= 975 lbft> 921 lb -ft OK Load Case: DLQ.6W N/A N/A Pnet+PmcoslBl+Pv,= 71.3 pIf 2.88 Max Moment, M,=wL°/8= 986 lb -ft Mallowable = Sx x Fb'(wind)= 1357 lb -ft > 986 lb -ft OK Pv max Shear= 229.4lbs 1.0 Shear, V,=wL/2+Pv Point Load= 390 lbs N/AA Max Shear, V,=wL/2+PV Point Load= 456 lb Em,,,= Member Capacity N/A N/A DFA No.2 N/A 1.76 276-220-0064 2X6 Design Value C, C, Q C, KF Cl�FN Section Modulus, Sm= Adjusted Value F, = 900 psi 1.0 1.3 1.0 1.15 2.54 0.85 1346 psi F, = 180 psi N/A N/A 1.0 N/A 2.88 0.75 180 psi E= 1600000 psi N/A N/A 1.0 N/A N/A N/AA 1600000 psi Em,,,= 580000 psi N/A N/A 1.0 N/A 1.76 0.85A 580000 psi Depth, d = 5.5 in Width, b= 1.5 in Cross-Sectonal Area, A= 8.25 in Moment of Inertia, Im= 20.7969 in Section Modulus, Sm= 7.5625 in' Allowable Moment, M,n=Fe Sa= 847.916 -ft Allowable Shear, Va11=2/3F,'A= 990.0 Ib DCR=M„/M,ii= 0.86<1 Satisfactory DCR=V,/Vzn= 0.42<1 Satisfactory = EV projecn@evengineersnet.com 276-220.0064 ENGINEERS http;//www.evengineersnet.com =-EV projects@evengineersnet.com 276-220,0064 ENGINEERS http;//www,evengineersnet.com Siesmic Loads Check Roof Dead Load 1 10 psf %or Roof with Pv 19.6% Dpv and Racking 3 psf Average Total Dead Load 10.6 psf Increase in Dead Load 2.9% OK The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans - ERIN HOWARD. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this Structures assessment are only for the proposed solar panel Installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. IMV EV projects@evengineersnet.com � ENGINEERS http://www.evengineersnet.com 12/22/2021 RE: Structural Certification for Installation of Residential Solar ERIN HOWARDA076 MILLER R, WHEAT RIDGE, CO 80033 Attn: To Whom It May Concern 276-220-0064 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composite shingle roofing over roof plywood supported by 2X6 Rafters at 24 inches. The slope of the roof was approximated to be 19 degrees. After review and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the Imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SLID is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. Code 2018 International Residential Code(A$CE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 107 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 30 psf If you have any questions on the above, please do not hesitate to call. LICpN Sincerely, pppp0 pig NWaeySFO C Vincent Mwumvaneza, P.E. ppssiaa EV Engineering. g & LLC s.� '0e Proiectstmeyeneineersnet.com s/NNPLE http://www.eveneineersnet.com EXP:10/31/2023 =- EV projects@evengineersnetmm ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation Date: 12/22/2021 Job Address:'AMVMWR CT WHEAT RIDGE, CO 80033 Job Name: ERIN HOWARD ad 276-220-0064 Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet Cover Attachment checks Snow and Roof Framing Check Seismic Check and Scope of work Engineering Calculations Summary Code 2018 International Residential Code (ASCE J-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Uve Load Lr 20 psf Ground Snow S 30 psf Wind Load (component and Cladding) V 10] mph Exposure C 2 NDS for Wood Construction �kuwuq eys'`o Sincerely, oasaisa' �a qnc a Vincent Mwumvaneza, P.E. �'aYaxpla�\ ZYV EV Engineering,LLC Proiects(aleyeneineersnetcom E%P:10/31/2023 http://www.evengineersnet.com =- EV projects@evengineersnet.com 276-220-0064 � ENGINEERS hftp://www.evengineersnet.com Wind Load Cont. Risk Category= II Wind Speed (3s gust), V= mph ASCE 7-16 Figure 26.5-16 Exposure = Kn= 1.0 ASCE 7-16 Sec 26.8.2 K,=- ASCE 7-16 Table 26.10-1 Ku= 0.85 ASCE 7-16 Table 26.6-1 Ke= 1.00 ASCE 7-16 Table 26.9-1 cli 0.00256K,K,rKaK,V7= 21.14 psf Pitch =k11 Degrees YE=Conservatively assuming all exposed Y,conservatively assuming 10 ft2 effective area y Ips' (w) zonaiize) zona(2r, 2n) Zone(30) aonel3r) Fig. 30-3-2 GCS -1.1 -2 -2 -2.4 E9. Z9.4-7 P=9n(GCp)(yE)IY,)= -27.90 -50]3 -50.73 -60.88 GCp 0.5 Figure 30.3-2 P=Qh(GC,)(YF)(Y,)= 12.68 Equation 29.4-7 Rafter Attachments: 0.6D40.6W (CD=1.61 Connection Check Attachement max. spacing= ft 2 66 lbs/in Table 12.2A-NDS Lag Screw Penetration 2.5 in DFLAssumed Prying Coefficient 1.4 Allowable Capacity= 76016s Zone Trib Width Area (ft) Uplift(Ibs) Down(Ibs) Zore(1,3e) 6 19.5 271.2 229.4 Zone(zr, Zn) 6 9.8 235.7 229.4 Zonel3e) 6 9.8 235.7 229.4 Zone(3r) 6 9.8 280.3 229.4 Conservative Max- 280.3 < 760 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind upliftgoverns 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. =V EV projects@evengineersnet.com � ENGINEERS http;//www.evengineersnet.com ..., -30 Design Value pg=.,. C, psf C, = 0.9 Cl�FN C, = 1.1 Allowable Moment, M,n=Fe Sa= 1, = 1.0 1.0 p,= 21 psf paam. = 30.0 psf p,= 30 psf Max Length, L = Tributary Width, WT= Dr = PVDL = Load Case: UL .75(0.6W+S) O.75(Pnet+Ps)+ Pmcos(B)+PD,= Mdo, Mallowable = Sx x Fb'(wind)= Load Case: DL+S CS= 0.9 51 pIf 24 in 10 psf 20 pit 3 psf 6 pIf 74 pIf 1023 Ib -ft 1357 Ib -ft > 3023 Ib -ft OK 276-220-0064 Ps+Pecos(B)+PD,= 67 pIf Mdo 921 lb -ft Mallowable = Sx x Fb'(wind)= 97516 -ft > 921 lb -ft OK Load Case: DLQ.6W Pnet+Pmcos(B)+PD,= 71.3 pIf Max Moment, M,=wL°/8= 986 lb -ft �Or Mallowable = Sx x Fb'(wind)= 1357 lb -ft > 986 lb -ft OK Pv max Shear= 229.4lbs Shear, V,=wL/2+Pv Point Load= 390 lbs g�qA Max Shear, V,=wL/2+PV Point Load= 45616 Member Capacity DFA No.2 2%6 Design Value C, C, Q C, KF Cl�FN Section Modulus, Sm= Adjusted Value Allowable Moment, M,n=Fe Sa= F, = 900 psi 1.0 1.3 1.0 1.15 2.54 0.85 1346 psi F, = 180 psi N/A N/A 1.0 N/A 2.88 0.75 180 psi E= 1600000 psi N/A N/A 1.0 N/A N/A N/AA 1600000 psi Em,,,= 580000 psi N/A N/A 1.0 N/A 1.76 0.85A 580000 psi Depth, d = 5.5 in Width, b= 1.5 in Crass -Seasonal Area, A= 8.25 in Moment of Inertia, Im= 20.7969 in Section Modulus, Sm= 7.5625 in' Allowable Moment, M,n=Fe Sa= 847.916 -ft Allowable Shear, Va11=2/3F,'A= 990.0 Ib DCR=M„/M,ii= 0.86<1 Satisfactory DCR=V,/Vzn= 0.42<1 Satisfactory = EV projecn@evengineersnet.com 276-220.0064 ENGINEERS http;//www.evengineersnet.com =-EV projects@evengineersnet.com 276-220,0064 ENGINEERS http;//www,evengineersnet.com Siesmic Loads Check Roof Dead Load 1 10 psf %or Roof with Pv 19.6% Dpv and Racking 3 psf Average Total Dead Load 10.6 psf Increase in Dead Load 2.9% OK The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans - ERIN HOWARD. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this Structures assessment are only for the proposed solar panel Installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L, Job Address: 40t5 W L--L.-i� C'T- Permit Number: Q%Q( j 0,44,4�0 T ❑ No one available for inspection: Time 2 AM�'}N Re -Inspection required: Yes(No)`--'` When corrections have been made, call fqr r -inspection t 303-:234-5—.9133 Date: )-,?,b i { ))77_ Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: h Job Address: Permit Number: b / 4 c/ t/ 6 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: ! Inspector: +p DO NOT REMOVE HIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201704440 PERMIT NO: 201704440 ISSUED: 07/19/2017 JOB ADDRESS: 4075 Miller CT EXPIRES: 07/19/2018 JOB DESCRIPTION: Residential Re -roof to TEAR OFF 1 LAYER AND INSTALL 15 SQ GAF TIMBERLINE asphalt shingles with ROOF DECKING 15SQ 6/12 PITCH HOUSE *** CONTACTS *** OWNER (720)385-5489 BELFOR SUB (303)296-8551 Production 019898 AVI, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,706.00 FEES Total Valuation 0.00 Use Tax 119.83 1 D Permit Fee 140.90N" 1% ** TOTAL ** 260.73 _ *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201704440 PERMIT NO: 201704440 ISSUED: JOB ADDRESS: 4075 Miller CT EXPIRES: JOB DESCRIPTION: Residential Re -roof to TEAR OFF 1 LAYER AND INSTALL asphalt shingles with ROOF DECKING 15SQ 6/12 PITCH 07/19/2017 07/19/2018 15 SQ GAF TIMBERLINE HOUSE I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work two be performed is disclosed in this document and/or its' accompanying approved plans and specifications. 17 Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief in, Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all re uired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issua ranting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable co i anreg ati of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz '-f `1 L4 c) From: no-reply@ci.wheatridge.co.us Sent: Tuesday, July 11, 2017 9:32 AM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a residential roof? How many dwelling units are on the property? Yes Single Family Home, Duplex PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address 4075 Miller Ct Belfor 303425970 Field not completed Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Cara Meyer Contractor's License 19898 Number (for the City of Wheat Ridge) Contractor Phone 3032968551 Number Contractor Email Address production@aviroofing.com Retype Contractor Email production@aviroofing.com Address DESCRIPTION OF WORK Are you re -decking the Yes roof? Description of Roofing Material Select Type of Material: If "Other" is selected above, describe here: How many squares of the material selected above? Does any portion of the property include a flat roof? If yes, how many squares on the flat roof? Tear off 1 of 1 layers and install 15 sq of Gaf Timberline. Asphalt Field not completed. 15 sq No Field not completed TOTAL SQUARES of all 15 roofing material for this project Provide additional detail 6/12 / house here on the description of 2 work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 5706 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Cara Meyer Email not displaying correctly? View it in your browser. 3 PHONE: 303-296-8551 E-mail: office@aviroofing.com www.aviroofing.com � AVI.q FAX: 303-296-8557 Name: BELFOR CELL# 0 Home Phone: 303-425-9700 Email: 0.00 Billing Address: 5085 KALAMATH ST DENVER CO 80221 Job Address: 4075 MILLER CT WHEAT R CO 80033 AVI Roofing, Inc. ("Contractor') agrees, subject to the Additional Terms and Conditions on the reverse side of this Proposal & Agreement, to furnish all materials, labor and equipment necessary for the work specified below located at the address stated above: DESCRIPTION OF WORK TO BE PERFORMED AND MATERIALS TO BE SUPPLIED: 15.00 sqs GAF TIMBERLINE COLOR 0.00 Shingle Manufacturer and Field Squares 4 bundles SEAL A RIDGE H&R 12" X 25' Ridge Type 30 ears Manufacturers Warranty y AVI Workmanship Warranty 5 years Tear off existing roof layers and haul away 1 layers Install base felt 2 rolls RINO replace flashings 2 each Remove and plumbing Install all new roof vents 2 each DURAFLO WP 50 Install valley material 2 rolls 90LB Install 2 X 2 rake flashing 184 feet WHITE Install 2 X 4 eave flashing 119 feet WHITE Corrigated metal panels 24 each furnished by AVI Permit SPECIAL INSTRUCTIONS: this contract within 72 hours of the date signed on this contract. 1 The Home Owner has a 3 day right of recision to cancel date is . The job should take at total of days. 2 The approximate work start 3 The price on this contract does not include Lead Mitigation. is deterioated AVI will remove and replace it with your approval at an additonal . 4 Decking will be inspected after the roof is torn off and if material s CONTRACT PRICING: RE -ROOF PRICE: GUTTERS' GUTTERS 133 DOWNSPOUTS 40 51NCH TOTAL CONTRACT PRICE: F' Payments to be made as follows: 50% is due upon delivery of materials. The balance is due upon completion of work. y All money collected prior to the job starting will be held in a separate account until the job is at least 50% complete. i If payment is made by credit card a 5% service charge will apply. d Replacement of deteriorated decking, fascia boards; roof jacks, ventilators, flashing or other materials, unless otherwise stated in this Proposal & Agreement are not included and will be charged as an ea any replaced wood and / or metal. The contrac basis. Owner is responsible for removal of all outdoor furniture, awnings, or other outdoor fixtures prior to the start of the Work. Owner to prime and paint to harmless this material in the event that such material is d le render perform work relating to asbestos or polychlorinated biphenyl (PCB). Owner will be responsible for the additional cost of removal or cost ) the expiration date is extended in writing by the contractor and this Proposal & Agreement is thereafter accepted by Agreement will expire in ten (10) days from date unless accepted writing within that time Owner, unless with costs in effect at that time. All proposals are subject to approval of Contractor's Owner before the extended expiation date. Also, after 10 days from the date below, Contractor reserves the right to revise its price in accordance Management. and are hereby accepted. AVI Roofing, Inc. is authorized to do the work as specified. The above prices, specifications and conditions are satisfactory ACCEPTANCE OF PROPOSAL: This agreement made this day of 20 l/ Date Customer Signature I have read and understand the Additional Terms and Conditions are part of this Proposal & Agreement. By signing this agreement MIKE DANCAUSE 05/18/17 Date Salesmen Signature 5085 KALAMATH ST. DENVER CO 80221 PHONE: (303) 425-9700 FAX: (303) 425-9499 VENDOR 962295 AVI, Inc 1290 E. 58th Ave Denver CO 80219 ORDERED BY SCHEDULED START ACTUALSTART SCHEDULED FINISH ACTUAL FINISH DESCRIPTION Roofing repairs per invoice Notes/Special Requests: PO NUMBER 201931 ORDER DATE 06/16/2017 REQUESTED DATE 06/16/2017 SHIP TO KREISLER, SKYE 4075 MILLER COURT WHEAT RIDGE CO 80033 JOB NUMBER JOB NAME DIVISION ESTIMATOR PROJECT MANAGER DELIVERY TERMS 101049489 KREISLER, SKYE 10 YEAR McArthur, Craig Kindell, Hank DESTINATION Non -Taxable Amount Taxable Amount Sales Tax - 0% Total Order This Subcontract Order and any attachment to this Subcontract Order will covenant to those terms and conditions on BELFOR's Master Subcontractor Agreement and/or Work Agreement by and between BELFOR and above subcontractor. AUTHORIZED BY BELFOR REPRESENTATI SUBC NTRACTOR SIGNATURE R5543510 17 DATE WINDOW WELL DETAIL. CASEMENT WINDOW MIN FULLY OPEN BASEMENT WALL LADDER REQUIRED IF 44' DEEP ELL IS OVER mmmm�� CONCRETE4* X 4' 1/4' WELDED STEEL FRAME, INSERT FRAME INTO CONCRETE FROM OUTSIDE AND SEAL FLANGES WITH RESILIENT SEALER, ATTACH TO FASTENERS.1/4' CONCRETE 7. 4 3" MIN ENI VIES/ OF FRAME F7 r EXTENDED CUTOUT-// FRAMEWHEN NECESSARY USE MULTIPLE SETS OF 4* LONG STEEL SHIMS TOTALING 12' IN WIDTH BETWEEN FRAME AND ORIGINAL WINDOW FRAME, OR , FRAMEAND CONCRETE, TO FORCE BOTTOM OF NEW FRAME AGAINST BOTTOM OF CONCRETE CUTOUT, OR BETWEEN BOTTOM OF 0' MIN /-53 SO FT MIN 29.25' 37.2 47.5' ,P' 44" g MAX '—FRAME FACE VIEW OF FRAME EGRESS WINDOW DETAIL KEEP TOP AND SIDES OF ORIGINAL FLOOR GR WINDOW FRAME IN PLACE, DO NOT THIS DESIGN MEETS THE FOLLOWING REQUIREMENTS CHANGE OR REMOVE ANY 1. 2009 & 2012 IRC/IBC FOUNDATION WALL OR STRUCTURAL . IID mph EXP C WIND FRAMING ABOVE WINDOW . 35 sec. GUSTS 4. ROOF SNOW LOAD 30 l./sq ft . GROUND SNOW LOAD 423 tioJsq ft . SEISMIC D MCaCIRY DF�BA�SEMENT ERE WT9lW IIET�L 4075 MILLER COURT W IE TRIDGE, C . SIZE FSCM NO, DWG A REV MC -001 ___[IA sHEr 1 OF 1 11 x.114 "it, 1' a lk—is R.d l;s '4,J.I It #! 1 'Buildin .. InspectionDivision 7500 W. eRidge,Q1 80033 Office:• e • r Building Permit Application Property Address: m,')1tP- 1 • # •sem .•♦ City, State, i 2Z, i Architect/Engineer E -mai sV --3C" W _ _. 16__ . r � � a Plumbing- Mechanicat Complete all infonnation on BOTH sides of this form !- o�j�j (Check all that apply) 0 NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE COMMERCIAL ROOFING COMMERCIAL ADDITION RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY>,• shed, deck, A A w r* A ae*• : yp or w A CEMENT PLUMBING !! AALIANCE REPA 7IR o ELECTRICALr REPLACMENT SYSTEMIAPPLIANCE REPAIR Ilb AR o REPLACEMENT r. r. r _. mount of Materials to -used, etc.) -° v\ I? Iv a v p V 1 +^ , � .A I .r° 97 AW SA-ewOv Sq. RAY aws _w Gaffons Arnim ProlaO Value: (Contract value or the cost of I#materialsarta labor included in the ft project) tit OWNERYCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this pe nit application are accurate anad do not violate applicable ordinances males or regulations of the City of Wheat Ridge or covenants, easements or restrictions, ofrecord; that all measurements shown and allegations made are accurate that I have read andagree to abide by all conditions printed on this application cation Haat l assume full responsibility for compliance with applicable City of Wheat Ridge cmits, and ordinances for work umler aky permit issued hucnd can this application„ that I am the legal owner or have been authorized by die legal owner of the property to perfonn the described work and atn also authorized by the legal owner of any entity included on this application to list dial ctityy on this application, C RCIX, ONE, (OWNER) (CONTRACTOR) CTO) rax° ( HORI .:isRFI'III FNfATI ) of (OWNER) (CONTRACTOR) WINDOW WELL DETAIL CASEMENT WINDOW 0* MIN FULLY OPEN--,, 26' X 44` OPENING 4' X 4' 1/4' WELDED STEEL FRAME. INSERT FRAME INTO CONCRETE #UTSIDE AND SEAL FLANGES WITH RESILIENT SEALER. ATTACH TO CONCRETE WITH 1/4' CONCRETE FASTENERS, 4" 36' MIN END VIEW OF FRAME F7 p t i } y L. _ 4 EXTENDED CUTOUT NECESSARYWHEN FRAMEUSE MULTIPLE SETS OF 4* LONG STEEL SHIMS TOTALING 12' IN WIDTH BETWEEN ORIGINAL CONCRETE,AND OF NEW FRAME 1 i BOTTOM O BOTTOMCONCRETE CUTOUT, OR BETWEEN OF FRAME O R Is 44- 1 MAX --FRAME FACE VIEW OF FRAME GE SS WINNOW DETAIL KEEP TOP AND SIRES OF ORIGINAL FLOOR WINDOW FRAME IN PLACE. DO NOT THIS RESIGN MEETS THE FOLLOWING REQUIREMENTS CHANGE OR REMOVE ANY L 2009 & 2012 IRC/IBC FOUNDATION ATION WALL OR STRUCTURAL . 110 mph EXP C WINK FRAMING ABOVE WINDOW 3, 35 sec. GUSTS 4, ROOF SNOW LOAD 30 Lb'/ q ft . GROUND SNOW LOAD 42,9 (lo,/sqt . SEISMIC DESI TEGI RY . �tF BASEMENT EGRESS WINDOW 4075 MITER COURT W EATRIDGE k CO si=NO.� O. REV :MC -001 ,q SCAB, 1/4" V CRATE s MAR 2015 SHEET 1 0F° I WINDOW WELL DETAIL CASEMENT WINDOW " MIN FULLY OPEN LADDER REQUIRED BASEMENT WALL IF Wn CMI OVER azlmmo�� 4' 1/4' WELDED STEEL • # INSERT FRAME # CONCRETE FROM OUTSIDE AND # FLANGES WITH RESILIENT SEALER. ATTACH CONCRETE 1/4' CONCRETE FASTENERS, 3" IN END VIEW OF FRAME E F-1 1 t e r L 8 EXTENDED CUTOUT �/ Mum NECESSARYWHEN TOTALINGUSE MULTIPLE SETS OF 4' LONG STEEL SHIMS 1 BETWEEN FRAME AND ORIGINAL FRAME,ORFRAME AND CONCRETE, TO FORCE BOTTOM OF *# AGAINST BOTTOM CONCRETE CUTOUT, OR BETWEEN BOTTOM OF FRAME AND CONCRETE, i 44- 1 MAX•# H FLOOR EGRESS WINDOW DETAIL KEEP TOP AND SIDES OF ORIGINAL WINDOW FRAME IN PLACE. DO NOT THIS DESIGN MEETS THE FOLLOWING REQUIREMENTS CHANGE OR REMOVE ANY L 2009 & 2012 IRC/IBC FOUNDATION WALL OR STRUCTURAL , 110 mph EXP C WIND FRAMING ABOVE WINDOW 3. 35 sec. GUSTS . ROOF SNOW LOAD 30 (b./sq (b./sFt G. GROUND SNOW IUAII 4. (b,/sq Ft , SEISMIC DE TZGORY E E6 T EGRESS Cl i ETAI 4075 MILLER COURT ETiE, CO SIZE FSCM NO. DW NO. REV . ' Sc � E �� a ,TE a SHEET I OF I INSPECTION RECORD Occupanc °'INSPECTION LINE (303) 234 -5933 Inspections will not be made unless this card is posted on the building site I Call by 3:00 PM to receive inspection the following business day. / - 7 � j i/ 019 E l t; n /Ul n ('a i .- Uvv. IA INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS J OB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Stemwall / (CEG) Concrete Encased Ground y Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. CONCRETE SLAB FLOOR Electrical Heating (Underground) ROUGHS Sheathing Lath /Wall tie Mid -Roof y Electrical Service Rough Electric Rough Plumbing Gas Piping INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Rough Mechanical * * NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTEAUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. CVIIVV Framing Insulation Drywall Screw i FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping * * NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTEAUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER " 1 City of Wheat Ridge -ter ► J Residential Electric PERMIT - 110586 PERMIT NO: 110586 ISSUED: 05/23/2011 JOB ADDRESS: 4075 MILLER CT EXPIRES: 05/22/2012 DESCRIPTION: 200 amp service upgrade * ** CONTACTS * ** owner 303/525 -7203 Wesly St. John sub 303/424 -9733 John Basil 01 -8765 Basil Electric ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0207 BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 2,250.00 FEES" Permit Fee 93.35 Total Valuation .00 Use Tax 40.50 ** TOTAL ** 133.85 - Conditions: Must comply w/ 2006 IRC & 2005 NEC. Subject to field inspection. 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction w' rs permit. I further attest that I am legally authorized to include all entities named within this document as parties . work to be performed and that all work to be performed is disclosed in trh "is" document and /or its �� anyia app "r s d plans and specifications. Signature of OWNER Lrt._,QQWE2_CTOR (Circle one) / Date/ 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. S. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspect'on Signature of e lding Offical Date INSPECTI REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. m hdf City Of `JET heat" C COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 " Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application J" 1 operty Andress: 40 7 S t 1 t r L. Date: Plan # Permit # l D J Property Owner (please print): ) 2SL u ' ,�}J,/>k j r\ Phone:,3()3— S,l S- 7� Mailing Address: (if different than property address) Address: City, State, Zip: Contractor: basi 1 P— I ec.'h<< L Contractors City License #: Electrical: Plumbing: City License # City License # U Cg e-.,P—,j i � aoO Amps BTU's Gallons Ft. - Ya- -/ -9 733 Mechanical: City License # Contract Value: $ 0 Review Fee (du $ e at time of submittal): OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by rids permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) SIGNATURE: Bldg Valuation: 5 / .) 3 3 'NSPEC. RECORD ` Occupancy/Type INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless, this card is posted on the building site ( Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB " FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Mid -Roof - Electrical Service Rough Electric Stemwall / (CEG) Concrete Encased Ground Gas Piping Rough Mechanical Reinforcing or Monolithic Insulations ' Drywall Screw Weatherproof / French Drain - ... Sewer Service Lines '. Water Service Lines INSPECTIONS FOR PLANNING & ZONING, FIRE AND.PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR SO FINAL INSPECTIONS. CONCRETE SLAB FLOOR Electrical (Underground) t'. Heating (Underground) ROUGHS Sheathing Lath /Wall tie Mid -Roof - Electrical Service Rough Electric Rough Plumbing Gas Piping Rough Mechanical Framing Insulations ' Drywall Screw ` K.. OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. I' OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED r PROTECT THIS CARD FROM THE WEATHER POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING FINALS Electrical Plumbing Mechanical Roof .. Building Final - ... Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND.PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR SO FINAL INSPECTIONS. Parking & Landscaping "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY !SlSSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION ♦ i CITY OF WHEAT RIDGE � Building Inspection Division (303) 234 -5933 Inspection line J (303) 235 -2855 Office • (303) 235 -2857 Fax INSPECTION NOTI I E c j t 7 ! �— Inspection Type: , r" d &: �.- ,,,, s Job Address: , r 7 f Permit Number: ❑ No one available for inspection: Time AM /PM Re- Inspection required: Yes No * When corre have been made, call for r at 303 - 2345933 Date: ¢ ` iSpector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE ~-j Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: .e Job Address: Permit Number: r1 3 rr l ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No "When corrections have been made, call for re-inspection at 303-234-5933 Date: 9 z l~,q Inspector: i~ 41- 1 DO NOT REMOVE THIS NOTICE a 41 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office * (303) 235-2857 fax , INSPECTION NOTICE Inspection Type: Job Address/Permit Number: ~(i 7;C Ur"1f~a C JQ6 a ❑ No one available for inspection: Time P71f) MOM Re-Inspection required: Yes f`.No When corrections have been made, call for re-inspection at 303-234933 Date: - t Inspector: A. 7- DO NOT REMOVE THIS NOTICE 41 City of Wheat Ridge roooo"P" Residential Roofing PERMIT - 091968 PERMIT NO: 09196$ ISSUED: 09/03/2009 JOB ADDRESS: 4075 MILLER CT EXPIRES: 03/02/2010 DESCRIPTION: Reroof 13.33 sqs ***.CONTACTS owner 303/431-4694 Wesley St. John sub 719/492-1396 Whitney Smith 08-0243 Seaback Roofing * * PARCEL INFO * ZONE CODE: UA USE: UA SUBDIVISION: 0207 BLOCK/LOT#: 0/ - - FEE SUMMARY :ESTIMATED PROJECT VALUATION: 2,610.50 FEES Permit Fee 108.30 Total Valuation ,00 ¢ C~~ ~ - k Use Tax 46.99 gas - **TOTAL 155.29 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measuremeX/,~pts shown, and allegations made are accurate; that I have read and agree to abide. by all conditions printed on this applicar'on and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applic le Wheat edge Ordi ances, for work under this permit. Plans subject to field inspection. yl , Srgnai~¢re ,of contractor/owner date This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. - This permit shall. expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion. of the Building Official. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension. or abandonment exceeds one (1) year, full fees shall - be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem...., Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written. approval on inspection card before proceeding with successive phases of the job. The issuance of a permit or the approval of drawings. and specifications shall not be construed to be a permit for, nor an approval of, any iolation of the. provisions of the building codes or any other ordinance, law, rule Or regulation. All plan rev'ew s ject to field inspections. ignature of 'ef. ilding Official - date :NSPECTI REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 :EQUESTS.. MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. SEP-03-2009 THU 10:00 AM SEABACK ROOFING-RESTOR FAX No. 2$13452441 P.001 " r City of Wheat Ridge Building Division Date: ICj ~~J ~G~ u t o 7500 W. 29°i Ave., Wheat Ridge, CO 80033 r Office: 303-235-2855 - Pax: 303-235-2857 Plan Inspection Line: 303-234-5933 o AQ l Permit Building Permit Application i .r41?eGty: ddress= lv irJ MI ~ y AL Property Owner (please prinO-164QA-1 9~. TAAVr M Mailing Address: (if different than property address) Address: City, State, Zip: ''oryRctar: Contractor License 1Wx!oh k,hft(= Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Gate: Approval: ~r yApproval: Approval: Use of space (description): s4~L7 K alt construction Value: S Zti? 1 ~1 ~ 00 ~ Yt,RfpL'd`.Tl,',i6` Vpr c.,ta V, (as calculated per the Building Valuation Data sheen 10411- M bl A)_ Aq Plan Review (due at thne of subro t o: $ Sq. Ft.lL.Ft added: Squares iln BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit appllcation are accurate, and do not violate applicable ordinances, rules or covenants shon, and allegations made are accu ate: that Iheat have read and agree to Ib dame all conditionsoprinted onrtthisaapplicationaand that I assume full asponsibility for compliance Wth the Wheat Ridge Building Code (44 and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field Inspection. CINLCEONF:' (OWNER) T or PERSONAL REP 4ENTAT of(GWNER) NTRA70R) Q PR1N7 NAME SIGNATURE: Data`{ 2009-09-03 08:26 SEABACK ROOF 2813452441 Page 1