Loading...
HomeMy WebLinkAbout4370 Dudley StreetCity of Wheat Ridge E -Res. Boiler Replacement PERMIT - 202000634 PERMIT NO: 202000634 ISSUED: 04/01/2020 JOB ADDRESS: 4370 Dudley St EXPIRES: 04/01/2021 JOB DESCRIPTION: Replacing gas boiler 150k BTU, 83% efficiency in basement. *** CONTACTS *** OWNER (303)718-3176 COSOLO MARY ANN SUB (303)421-3572 WILLIAM BURAS 017865 LAKESIDE HEATING & A/C *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE. UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,500.00 FEES Boiler Replacement 40.00 Total Valuation 0.00 Use Tax 199.50 ** TOTAL ** 239.50 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Smoke alarms shall comply with 2012 IRC Section 134. INTERIOR ALTERATIONS, REPAIRS, FUEL -FIRED APPLIANCE REPLACEMENTS, OR ADDITIONS, ANY OF WHICH REQUIRE A BUILDING PERMIT, OCCURS OR WHERE ONE OR MORE ROOMS LAWFULLY USED FOR SLEEPING PURPOSES ARE ADDED SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN FIFTEEN FEET OF THE ENTRANCE TO EACH ROOM LAWFULLY USED FOR SLEEPING PURPOSES '► � a 4 City of Wheat Ridge E -Res. Boiler Replacement PERMIT - 202000634 PERMIT NO: 202000634 ISSUED: 04/01/2020 JOB ADDRESS: 4370 Dudley St EXPIRES: 04/01/2021 JOB DESCRIPTION: Replacing gas boiler 150k BTU, 83% efficiency in basement. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authonzed by the legal owner of the property and aaut horized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermrt fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. T suance or gra t°ng of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any a l° ble code or ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. CRY nfWatRidgc, 04/01/2020 10:00 CDBB Replacing gas bohor CDB022755 AMOUNT 8PSF 4370 Dudley St 239.50 APPL/PERMlTNO: 202000634 PAYMENT RECETVED AMOUNT FP / 4975 239,510 4UTH CO8Ef 13315368 TOTAL 239.513 Dina Kemp From: no-reply@ci.wheatridge.co.us Sent: Wednesday, April 1, 2020 8:36 AM To: CommDev Permits Subject: Online Form Submittal: Furnace/Boiler Replacement Permit Application Categories: Dina Furnace/Boiler Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or BOILER - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes replacement residential furnace or boiler like for like? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address Attach Credit Card Authorization Form - **DO NOT ATTACHED RANDOM FORMS** 4370 Dudley St. Mary Ann cosolo 303-718-3176 Field not completed. Credit Card Authorization Form .pdf CONTRACTOR INFORMATION Contractor Business Lakeside Heating & A/C Name I Contractor's License 017865 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-421-3572 Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address becky.b@lakesideheating.com Retype Contractor Email becky.b@lakesideheating.com Address DESCRIPTION OF WORK What type of unit is being Boiler installed? Number of BTUs 150000 What is the efficiency 83 (%) of the unit? Is the unit GAS or gas ELECTRIC? Where is the furnace or basement boiler located (for example, basement, crawlspace, etc)? Project Value (contract 9500.00 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit 2 has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Rebecca Buras Permit Email not displaying correctly? View it in your browser. 10/14/2009 WED 18:00 PAX 303 237 8929 303 Best Way 0002/002 INSPECTION RECORD Occunancy/TVpe 'ZiNSPECTION LINE: (303) 234-5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. I INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB WSPEGTOR FOUNDATION fNSPECT10NS DATE _ COMMENTS: Stemwail ! (CEG) Concrete _ Encased Ground Reinforcing or Monolithic Weatherproof/ French Drain Sewer Service Lines - - -Water Service Lines CONCRETE SLAB FLOOR Electrical (Underground) ROUGHS Sheathing . Lath / Wall tie Mid-Roof Electrical Service Rough Electric Rough Plumbing Gas Piping Rough Mechanical SJUMO PRIOR _ OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER ♦ i CITY OF WHEAT RIDGE r Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F.,r-L Qogv- Job Address: V..3>o DaoL sr Permit Number: OF"51 ❑ No one available for inspection: Time .ZS AM% Re-Inspection required: Yes o When corrections have been made, call for re-inspection at 303-234-5933 Date: /41 g/w Inspector: DO' NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 101DAZ:1F Job Address: °i370 d>ut7lfc/ 57- Permit Number: 0733x57 rJF,~/f' - /.J F t i ❑ No one available for inspection: Time ltJ.' Sad PM i Re-Inspection required: a_No When corrections have been made, call for re-inspection at 303-2345933 Date: / fv Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ~Sd¢£o4PrI4w6 4 /a ll3 ®®F Job Address: V31'70 I oo,'F y 57- Permit Number: a9~3~1 t r n F _-APFRO ef~ cl9r a/ /~fC rPTu f Aa~ v£ f ❑ No one available for inspection: Time FJoYg PM Re-Inspection required: Yes loD_ 'When corrections have been made, call for re-inspection at 303-234-5933 Dater < /2 'a Inspector: %sF DO NOT REMOVE THIS NOTICE ONSTRUCTION U PPORT ERVICES, INC. January 13, 2010 Mr. Frank Cosolo P~Rn9,7 o 33 of! 4370 Dudley Wheat Ridge CO 80033 RE: Repairs required for tile roofing installation. Dear Frank: I examined the repairs made toour attic that I required for the installation of concrete roof tile. The repairs were made in keeping with my design intent. The work to stiffen the attic is acceptable. There was a concern on the part of the city inspector about the nailing of the sheathing on the roof. The pattern is 8" on-center on the edges and 12" on-center in the field. Based on the head size it appears the nails are a minimum of 8d and the nails are properly driven in the sample examined. I accept the sheathing nails as presented on this project for the installation of the new concrete please contact me at your convenience. 7901 S. Adams Way Centennial, CO 80122-3601 303-221-1559 phone ConSupSergmae.eom " 1 City of `Wheat Ridge Faxed Roof Permit PERMIT - 093351 PERMIT NO: 093351 'ISSUED: 10/14/2009 JOB ADDRESS: 4370:. DUDLEY ST '.EXPIRES: 04/12/2010 DESCRIPTION: Reroof 39.63 : sqs CONTACTS owner 303/421-0437 Frank Casolo sub 303/394-2802 Tim O'Connell 01-7590 C J Roofing Co. PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION:. 0234 'BLOCK/LOT#: 0/ **FEE SUMMARY ESTIMATED .'PROJECT VALUATION: :.'22,739.20 FEES Permit Fee 472.30 Total Valuation f Use Tax `409.31 **TOTAL :.881.61 Conditions: Both front and back of permit need to be posted on job site. If one or the other is not present, INSPECTION WILL NOT BE PERFORMED..'. 6 nail installation& mid-roof inspection required. Board sheathing spaced more thana 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield required from eaveedge to 2'.,inside exterior walls.' ***Contractor/Property owner shall provide `.ladder(s) secured in place for inpsections:(. Subject to field inspection. I-hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules "or'. regulations of the city of wheat Ridge or covenants, easements or 'restrictions of record;. that all measurements shown, and allegationsmade are accurate;. that I have read and agree to abide. by all conditions printed on this application. and that 3 assume full.. responsibility for compliance with the Wheat Ridge Building. Code .(I.B.C)<and all other.. applicable Wheat Ridge Ordinances, for work under this :permit. Plans subject to field inspection. Signature of contractor/owner `date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the state of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other :applicable ordinances of the City.:'. 2. This permit shall expire 180 days from the issue date.. Requests for an extension must be received; prior to expiration date. An extension may. be granted at the. discretion of the. Building Official. 3. If this permit expires, a new permit may be acquired for a fee ofone-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment, exceeds one (1) year, P. full fees shall be paid for ..a new. permit. 1. No :work of any manner shall be done that will change the natural flow of water causing a drainage problem. S. Contractor shall notify. the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. S. The issuance of a permit or the.: approval of drawings and specifications shall not be ;construed to be a permit. for, nor an approval of, any violation of the provisions of the. building codes or any other ordinance, law; rule or regulation. All 'plan evi is subject to field inspections. ;ignatu o ief Building . Official date CNSP CTION. REQUEST LINE: (303)234-.5933 BUILDING OFFICE: (303)235-2855 3EQUESTS. MUST BE MADE BY 3PM ANY=BUSINESS'.. DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. INSPECTION RECORD OccupancylType 'INSPECTION LINE: (303) 234-5933 I Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings/Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) ROUGHS Sheathing Lath / Wall tie Mid-Roof Electrical Service Rough Electric Gas Piping Rouah Mechanical Framing Insulation Drywall Screw FINALS YOUR NO INSPECTIONS TO BE SIGNED PRIOR J Electrical - W 4 &Drainage INSPECTIONS Parking & Landscaping SHOULD BE C CITY OF WHEAT RIDGE 10/14/09 _ 3:55 PM cdba Timothy J OConnell RECEIPT NO.CDA00E888 AMOUNT DPSP-Reroof-39.63 sqs - 881.61 093351 Permit Fee 472.30 Use Tax 409.31 - PAYMENT RECEIVED AMOUNT VS .6736 881:61 Auth Code: 068988 "'NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AN TOTAL 881.61 CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDI . OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER From:CJ Roofing 3033942808 10114/2009 15:36 4883 P.001/001 10/14/2009 WED 14:29 FAX 303 237 8929 303 Best Way (j001/001 City of jocolo_LPDO"r1ame, : MMU/NTVTYiD1EVELOPME~~{NT`.~ it Building Division 7500 W. 29th Ave_, Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Facsimile Building Permit Application Property Owner (ple Mailing Address: (iiffd0erentthan property address) Address: h City, State, Zip: e!~ ~""_~.Q~t1fgFOP: Y ~F'0T'i v~./n l~ 8!V W`1~~'n. d`H f US@4f Sppace descn tlOnl: h t. ^ r S taAtllL» i Mtn Z_ (dueata'meofsubmitfal);$~r~ Sq. FtlC.Fi added: Squares' ~ ~ BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certiy that the setback distances proposed by this petm@ application are accurate, and tlo not Ymrate applicable ordinances, roles or regulations of the Cry of wheat Ridge or covenants, easements or restrictions of rerard; that all measurements shown, and allegations made are accurate: that I have lead and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Coda 0.8,C) and all other applicable Wheat Ridge Ordinances, for work under this permit- Plans subjacttofie inspection. CIRLCE ONE:: (O ! ) (CONTRACTOR or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR) ~a.. PRINT NAME: SIGNATURE:... Dale: I~A t -4 yy' G$r .~2 '3 l' ""^4~+ oTn x ss sy(~cCx,... a 3c''r1ti`F~+''j yy~ v (5, 9 ^tk 9 Egg! lp'l ~'k ~S. ti7G ~~t''Adt'iS~~S Y~L`r~~gSE5~1~+~Y~fi~i ~f}'YLa~ ~'^~s"e ll'~M1'Y h_+~2'Y~d.i'✓"F ",;„~i +Cbw 'rr L rs w' ~4eLL , n a ,v9~{jv s ~Fv n~ -a~nj~~~~,.u~ t*Fr• ~s4R sy rdi~ ~ < m ^r. a yea ~ s ~ ~ ~ e.+c•-~' ihX'V'twi~- ~htt ~n ~'¢~r~~~'~~it~~' S`i+t r.+ '~"^++k i'e r~5. ~.ydy~a s~HV v~rt~eM~ a.f v~ ta, 1..uS.tty y~' M' y~- e1 tt~ N"`,~rt'~t v` "^"u~' ? fft{ yr, ra3 t sa- 3 /r%5~~g y sr.y~-~i s m'vf c v~%z'~' a s$R.EY.ti (?sa f ay'`sr' _.N~ h . ~'~.~}.clPSi9"Y~.'S Av~S°Y' 3'Y 'r.~~• CI`^;µ~z UU~y~-6°i~a5`5t~xflls/Nq ~'FS r r1~~ WIN bldg Valuation: $ Credit Card Pa: Use credit card listed on fit Date: t Print name: t9 a t'rnayk r Signature, 0 ONSTRUCTION UPPORT ERVICES, INC. September 30, 2009 Mr. Frank Cosolo 4370 Dudley Wheat Ridge CO 80033 RE: Suitability for installation of a the roofing system on: 4370 Dudley Wheat Ridge CO Dear Mr. Cosolo: Thank you for the opportunity to examine your roof framing system to, determine the accept- ability for the installation of a new roofing system. We examined the attic to see the roof sup- ports, the house for existing drywall cracks or other evidence of movement and the exterior to see if there were large deposits of leaves and other material that accumulate in the valleys. There are always areas that are not observable and we attempted to determine the framing method in those locations. Please note, anytime you reroof there is a rapid change of loading as the old roof is removed and the new roof installed. This change in loading, movement of materials and men, and the pounding that occurs, can cause small drywall cracks. These are not structural. If you ob- serve any cracking, please call our office so we can make sure that there is nothing else that may have occurred. There was no significant storage in the attic space. It is assumed that no additional storage will be done in the attic. Loading the bottom chord of trusses can change their behavior. If heavy items are to be stored in the attic consult with CSS, Inc. to make sure the loading is ac- ceptable. W'~' ~~y✓ll C L,4) 1 ~ ~ n~ `T~Y'G Ifif".lT Y 4~~~Z,,gq~fN`"~'P~1 2 0`b''.$^d } 3 K~WiA^1gY .,45i`1W Ums i~"`~~..SaS,«'dn35kz1 ✓v~ ~l("S .N"y 0? 'v t~`$'l"~ ~'1~+r~ui"YO 41W ~ ~f ,3*I rnE` n Yl~' B^rv4j cl r-4t a. Snow Load 30 Local Code value Roofing Weight 11 Manufacturer Misc (sheathing, insulation, etc.) 4.0 Standard weights Total (psf) 45 Rafter Spacing (inches) 24 Measured value Top Chord Loading (per linear foot) 90 Calculated value The porch is modeled as shown. 7901 S. ADAMS WAY CENTENNIAL, CO 80122 303-221-1559 CONSUPSEROMAC.COM This framing is adequate. The rafter ties that are on every other rafter only stiffen this model. There are 5 sets of rafter on the front of the house that do not have the bracing and are too long as shown below. 90.00 lb/ft If the rafters are sistered with 10 foot sections they will be stiff enough. The model below shows the rafters with 2x6 sisters installed. This is adequate. The sistering shall be done as described below. 1. The connection is to be plated with a section of 2x6. 7901 S. ADAMS WAY CENTENNIAL, CO 80122 303-221-1559 CONSUPSER@MAC.COM 2. The section is to be 120" long and it will be set tight to the ridge. 3. The bottom end does not need to reach the top plate of the wall. 4. THE WORK IS BEST DONE AFTER THE OLD ROOF HAS BEEN REMOVED. 5. A strip can be cut in the ridge to allow the new sister to be slid along side the existing and then it shall be secured as described below. 6. The top of the 2x6 shall be flush with the roof deck. 7. The wood is to be glued using OSI PL-400, PL-Pro, PL-Plus or Gorilla Glue applied according to the glue manufacturer's instructions. 8. The 2x6 wood is to be attached using minimum 12d nails. 9. The nails can be pneumatically driven. 10.Install nails 4" on-center into the existing truss members. The valley rafters along the ends of this front sections shall be stiffened by adding a 2x4 per- pendicular to the existing valley rafter. The final configuration shall look like the photo be- low. 2. The section shall be a minimum of 96" long starting at the bottom of the valley. 3. The 2x4 shall be attached by applying a bead of PL-400, PL-Pro or PL-Plus adhesive to teh center of the 2x4 and then nailing it in place using minimum 12d nails 4" on-center driven up into the existing valley rafter. 4. There are two valley rafters to be stiffened. 7901 S. ADAMS WAY CENTENNIAL, CO 80122 303-221-1559 CONSUPSER@MAC.COM The "inverted T" shall be created by: 1. Adding a section of 2x4 to the bottom of the valley rafter. This opinion is based on the conditions observed. There are sometimes areas of framing that are not observable. Calculations for acceptability are based on the conditions observed using current versions of analysis software. Change of use or loading by conditions outside of those observed can change the results of the analysis. Alterations to the framing will require a new analysis. With these repairs, this house can carry an 11 psf concrete tile roofing system. 7901 S. ADAMS WAY CENTENNIAL, CO 80122 303-221-1559 CONSUPSERCaMAC.COM