Loading...
HomeMy WebLinkAbout10535 W. 32nd Avenuei CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE t Inspection Type: Job Addzz 1A" Permit Number: ' QE;�i - ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No. When corrections have been made, schod4le for re -inspection online at: http✓/www.ci.wheatridge.co.usllnspecti n:--�� Date i CITY OF WHEAT RIDGE �/- Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE C .�., r Inspection Type: _ Job Address: ,7 Permit Number: n`°- ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes When corrections have been made, schotMle for re -inspection online at: http://www.ci.wheatridge.co.ushnspecti n Date � ► � i City of Wheat Ridge -.A Residential Mechanical PERMIT - 202002483 PERMIT NO: 202002483 ISSUED: 12/01/2020 JOB ADDRESS: 10535 W 32nd Ave EXPIRES: 12/01/2021 JOB DESCRIPTION: Installing a new gas insert into an existing masonry fireplace to provide the necessary electrical and connect to the existing gas line in living room. Sq ft:L 700 *** CONTACTS *** OWNER ( 3 0 3) 5 8 8- 6 6 8 3 LEE WALDMAN SUB (303)887-4727 JASON BRENDLINGER & ANDREA LAU 060165 FIREPLACE & GRILL EXPERTS SUB (303)349-5257 DUSTIN DU PONT 160188 ALPHA ELECTRICAL CONTRACTING *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11500.00 FEES Total Valuation 0.00 Use Tax 31.50 Permit Fee 60.50 ** TOTAL ** 92.00 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. 1* ► � i City of Wheat Ridge -.A Residential Mechanical PERMIT - 202002483 PERMIT NO: 202002483 ISSUED: 12/01/2020 JOB ADDRESS: 10535 W 32nd Ave EXPIRES: 12/01/2021 JOB DESCRIPTION: Installing a new gas insert into an existing masonry fireplace to provide the necessary electrical and connect to the existing gas line in living room. Sq ft:L 700 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Interior Remodel Date: Wednesday, November 25, 2020 3:58:37 PM Residential Interior Remodel This application is exclusively for Residential Interior Remodels and other scopes of work which do not have a specific form already available. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 10535 W 32nd Ave Property Owner Name Caren Leaf Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 303-588-6683 Field not completed. Scanned Documents.Ddf APPLICANT INFORMATION Applicant Name Nate Mulcahy What is your role in the project? Wheat Ridge Contractor's License Number (This is a 5 or 6 digit number for the General Contractor 060165 City of Wheat Ridge) Contact Phone Number (enter WITH dashes, eg 303-123-4567) Contact Email Address for Plan Review Comments Retype Contractor Email Address DESCRIPTION OF WORK Detailed Scope of Work - In the space below (not as an attachment), Provide a detailed description of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc I, the applicant, understand my application will be rejected if I do not include a Detailed Scope of Work. 303-887-4727 info@thegaspro.com info@thegaspro.com install a new gas insert into an existing masonry fireplace provide the necessary electrical and connect to the existing gas line I have entered a detailed scope of work. Location of Work Living room Square Footage Area of Work Being Performed Asbestos Report Upload letter size documents here 700 Field not completed. Construction Plans Field not completed. scanned on 11'x17" or larger Project Value (contract 1500.00 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Nate Mulcahy Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. o i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE s Inspection Type: 0 Job Address: --- {-P L4 n Permit Number: -q10 -a� 0 � u ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No,. When corrections i have been made, call for re -inspection at 303-234-5933 Date: Inspector: K DO NOT REMOVE THIS NOTICE V o1 d 3 0 k4 o M V r 1* � � i City of Wheat Ridge �� Residential Plumbing PERMIT - 202002286 PERMIT NO: 202002286 ISSUED: 11/04/2020 JOB ADDRESS: 10535 W 32nd Ave EXPIRES: 11/04/2021 JOB DESCRIPTION: New gas piping installation from meter to 1 fire place and 1 stove - 200 ft *** CONTACTS *** OWNER (303)588-6683 LEAF CAREN MICHELE SUB (720) 568-0220 JUSTIN KRAFT 110279 JK PLUMBING INC. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 31000.00 FEES Total Valuation 0.00 Use Tax 63.00 Permit Fee 93.35 ** TOTAL ** 156.35 *** COMMENTS *** *** CONDITIONS *** All work shall comply 2018 International Codes, 2020 NEC (if applicable), and ordinances adopted by the City of Wheat Ridge. Work is subject to field inspections. I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications, applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Interior Remodel Date: Tuesday, November 3, 2020 9:24:34 PM Residential Interior Remodel This application is exclusively for Residential Interior Remodels and other scopes of work which do not have a specific form already available. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 10535 w 32nd ave Wheatridge CO 80033 Property Owner Name Caren Leaf Property Owner Phone 303-588-6683 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Field not completed. Address Attach City of Wheat oavmentwheatridae.odf Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" APPLICANT INFORMATION Applicant Name John Klosterman What is your role in the General Contractor project? Wheat Ridge 1235650 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contact Phone Number 720-514-3580 (enter WITH dashes, eg 303-123-4567) Contact Email Address jkplumbing777@gmail.com for Plan Review Comments Retype Contractor jkplumbing777@gmail.com Email Address 0]:R16]CII91M0N]MYLO]M:/ Detailed Scope of New gas piping installation from meter to 1 fire place and 1 Work - In the space stove. I have filled out a plumbing contractor licence i am John below (not as an Klosterman with JK Plumbing LLC please call me with any attachment), Provide a Questions 720-514-3580 thank you detailed description of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc I, the applicant, I have entered a detailed scope of work. understand my application will be rejected if I do not include a Detailed Scope of Work. Location of Work living room and kitchen Square Footage Area 200 of Work Being Performed Asbestos Report Field not completed Upload letter size Field not completed documents here Construction Plans Field not completed. scanned on 11'x17" or larger Project Value (contract 3000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for John Klosterman Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. Zot SOW S 10 L5 VSW 4e, INSPECTION RECORD INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Occupancy/Type Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior Te Annrnval Of Tho Ahnvc Incnnr+innc Underground/Slab Inspections Date Inspector Comments Initials Electrical Comments Sewer Service Plumbing Do Not cover Underground or Bellow/In-Slab Work Prior To Approval Of The Ahnvp Incnar-finne Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. rvr iow vurtage permns — riease De sure inai rough inspections are completed trom the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Roofing PERMIT - 201706213 PERMIT NO: 201706213 ISSUED: 08/16/2017 JOB ADDRESS: 10535 W 32nd AVE EXPIRES: 08/16/2018 JOB DESCRIPTION: Residential Re -roof to install Atlas Pinnacle asphalt shingles - 24 sq *** CONTACTS *** OWNER (303)733-5770 LEE WALDMAN SUB (303)984-7663 Judy Antener 070171 1-DERFUL ROOF & RESTORATION *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,200.00 FEES Total Valuation 0.00 Use Tax 151.20 Permit Fee 172.60 ** TOTAL ** 323.80 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Roofing PERMIT - 201706213 201706213 ISSUED: 08/16/2017 10535 W 32nd AVE EXPIRES: 08/16/2018 REVISION: Adding redeck to existing permit 24 squares Residential Re -roof to install Atlas Pinnacle asphalt shingles - 24 sq *** CONTACTS *** OWNER (303)733-5770 LEE WALDMAN SUB (303)984-7663 Judy Antener 070171 1-DERFUL ROOF & RESTORATION *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,800.00 FEES Total Valuation 0.00 Use Tax 226.80 Permit Fee 220.15 ** TOTAL ** 446.95 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge _J Residential Roofing PERMIT - 201706213 PERMIT NO: 201706213 ISSUED: 08/16/2017 JOB ADDRESS: 10535 W 32nd AVE EXPIRES: 08/16/2018 JOB DESCRIPTION: REVISION: Adding redeck to existing permit 24 squares Residential Re -roof to install Atlas Pinnacle asphalt shingles - 24 sq I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and thatfall w to be performed is disclosed in this docu and/or its' accompanying approved plans and specifications. `� _5 l Signature of O R or CONTRACTOR (Circle one) Date I. This permit w issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Offcial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and -Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a Dennit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. ppr al of work is sub'ect to fyel inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. o City of V V heat 1C] COMMUNITY DEVELCiPMEN"T Building & inspection Services Division 7500 W. 291' Ave., Wheat Ridge, CO 80033 0ffice: 303-235-2855 ' Fax: 303-2317-8929 Inspection Line: 303-234-5933 Email: permits ci.wheatridge.co.us FOR OFFICE USE ONLY l Date: Add to Permit # 201706213 1 � Building Permit Revision Amendment ApplitCation — Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. — Property Address: 10535 W 32nd Ave Property Owner (please print): Caren Leaf & Lee Waldman Phone: 720-313-5312 Property Owner Email: Mailing Address: (if different than property address) Address: City, State; Zip: SubmittingCompany:1-derful Roofing & Restoration Contact Person: Colleen Jacobsen Contractor: 1-derful Roofnu & Restoration Contractors City license #: 070171 Phone: 303-984-7663 Contractor E-mail Address: lderfulcolleen@gmail.com Phone: 303-984-7663 Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. if revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour — 2 hour minimum). Description of revised/amended work: Add re -deck 24 Sqs. Sq. FULF Amps Btu's Squares 24 Gallons Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) 3,600.00 OWNEWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRrNT NAIME. Colleen. Jacobsen ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: SIGNATURE: l�`�' �✓ PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY DATE:09/057;1 OCCUPANCY CLASSIFICATION: 8 I� Building Division Valuation: $ 9858 W. Girton Drive Lakewood, CO 80227 Proposal Date: _ Phone.- 303-984-ROOF(7663) 303-984-ROOF(7663) FR00FlN4i3 This proposal may be withdrawn by 1-Derful Fax: 855-696-7776 Roofing & Restoration if not accepted within 30 days from the above date. PROPOSAL FOR: Name: SUBMITTED SUBMITTED BY: 11-D ROOFING & RESTORATION .lob Address o j�' 1-Derful Rep: City, State, Zip: c,/ Cell Phone: ,'— Insurance Company: Phone: 103— Adjustor Information: Malting Address: Policy Number: F S 2 (If Different) /_�� Email Address: Claim Number: --.,:?_Cy Best way to contact: Tear Off and eaves are open or closed. J Gutters: Inspect Decking: Detenoratod existing decking color Outlet replaced at cost of $ Per Sq. Ft. Homeowner Siding: will be notified if any darflftiged wood is found during tear off. Install ice shield on eaves and in valley(s) ` Install drip edge_ ayc_:!K Color 0, Extra work Install underlayment Recover roof with year manufacturer warranty. 1I Shing e manufacturer color eki, 6 Nail everj�p hin AMAr I z nstall ridge stylenstallpipeks J lead jacks' swamp cooler Step flash sidewalls �lstep flash chimney J step flash skylight 1-Derful Roofing & Restoration will provide general liability insurance of at least $2,000,000 and Workers Compensation of at least $500,000 Clean up and haul of roofing debris Clean out gutters Magnetic sweep of surrounding area J Clean around landscaping All required Permits furnished by 1-Derful Roofing & Restoration to be reimbursed by Insurance Company 1-Derful Roofing & Restoration five year warranty on labor —� Current Ventilation Recommended IJ Decline recommendation on ventilation Date of Acceptance 1-Derful Roofing &Restoration Representativ Home Special instructions: 1-derful Roofing and Restoration, shall hold in trust any payment received from you until 1-derful has delivered roofing materials at the site or has performed a majority of the roofing work on your property. $ �°� -��y deductible to be collected at time of material delivery. $--2 17;", initial total claim amount as of _ '57- / , q /20 ( This price is subject to supplements/adjustments. Roof work to be completed within 21 days of final insurance approval and mortgage endorsement* Property Owner is not intending to make payment from the procee s of a property and jcasualty insurance policy. ;INSURANCE ALLOWANCE AGREEMENT If so, homeowner must read and sign belo 1W0 agree to retain 1-Derful Roofing & Restoration (contractor) to repat0replace the damaged or entire portion of the property described on company's approval and payment to have said work completed. It is agreed that the contractor is em y - neet c of damage, the cost of the repair or replacement of the damage to the aboveproperty. t g nl upon the contractor obtaining my insurance empowered to contact m insurance carrier and to meet with their representative in order to neootiate the amount and may begin on a first in first out basis. Upon the insurance carrier agreement with the contractor and the down payment being made the work will be scheduled Checks shall be made savable to 1 Derful Roofing 8 Restoration C the event that the insurance he customer's tails r' negotiate in a fair and reasonable manner, the contractor shalt not be held liable and this agreement will be void The contractor will release the complete rite to the Commissioner of Insurance c the customer's reguest. Insured out at pocket expense will not exceed the insured (purchaser) policy deductible for the work agreed upon between the insurance carrier and the contractor. Insured also agrees to provide all the necessary documentation for the claim (including documentation to facilitate payment from insurance carrier and/or mortgage holder). The contractor reserves the right to file for Supplemental claims due to material and/or labor increases due to a storm environment or to insurance adjuster's mistakes, errors or omissions. o —r,Nally Uwe agre b gning above to all the contract conditions on both the front and back of this agreement PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Roofing PERMIT - 201706213 201706213 ISSUED: 08/16/2017 10535 W 32nd AVE EXPIRES: 08/16/2018 REVISION: Adding redeck to existing permit 24 squares Residential Re -roof to install Atlas Pinnacle asphalt shingles - 24 sq *** CONTACTS *** OWNER (303)733-5770 LEE WALDMAN SUB (303)984-7663 Judy Antener 070171 1-DERFUL ROOF & RESTORATION *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,800.00 FEES Total Valuation 0.00 Use Tax 226.80 Permit Fee 220.15 ** TOTAL ** 446.95 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge _J Residential Roofing PERMIT - 201706213 PERMIT NO: 201706213 ISSUED: 08/16/2017 JOB ADDRESS: 10535 W 32nd AVE EXPIRES: 08/16/2018 JOB DESCRIPTION: REVISION: Adding redeck to existing permit 24 squares Residential Re -roof to install Atlas Pinnacle asphalt shingles - 24 sq I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and thatfall w to be performed is disclosed in this docu and/or its' accompanying approved plans and specifications. `� _5 l Signature of O R or CONTRACTOR (Circle one) Date I. This permit w issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Offcial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and -Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a Dennit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. ppr al of work is sub'ect to fyel inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. o 9858 W. Girton Drive Lakewood, CO 80227 Proposal Date: _ Phone.- 303-984-ROOF(7663) 303-984-ROOF(7663) FR00FlN4i3 This proposal may be withdrawn by 1-Derful Fax: 855-696-7776 Roofing & Restoration if not accepted within 30 days from the above date. PROPOSAL FOR: Name: SUBMITTED SUBMITTED BY: 11-D ROOFING & RESTORATION .lob Address o j�' 1-Derful Rep: City, State, Zip: c,/ Cell Phone: ,'— Insurance Company: Phone: 103— Adjustor Information: Malting Address: Policy Number: F S 2 (If Different) /_�� Email Address: Claim Number: --.,:?_Cy Best way to contact: Tear Off and eaves are open or closed. J Gutters: Inspect Decking: Detenoratod existing decking color Outlet replaced at cost of $ Per Sq. Ft. Homeowner Siding: will be notified if any darflftiged wood is found during tear off. Install ice shield on eaves and in valley(s) ` Install drip edge_ ayc_:!K Color 0, Extra work Install underlayment Recover roof with year manufacturer warranty. 1I Shing e manufacturer color eki, 6 Nail everj�p hin AMAr I z nstall ridge stylenstallpipeks J lead jacks' swamp cooler Step flash sidewalls �lstep flash chimney J step flash skylight 1-Derful Roofing & Restoration will provide general liability insurance of at least $2,000,000 and Workers Compensation of at least $500,000 Clean up and haul of roofing debris Clean out gutters Magnetic sweep of surrounding area J Clean around landscaping All required Permits furnished by 1-Derful Roofing & Restoration to be reimbursed by Insurance Company 1-Derful Roofing & Restoration five year warranty on labor —� Current Ventilation Recommended IJ Decline recommendation on ventilation Date of Acceptance 1-Derful Roofing &Restoration Representativ Home Special instructions: 1-derful Roofing and Restoration, shall hold in trust any payment received from you until 1-derful has delivered roofing materials at the site or has performed a majority of the roofing work on your property. $ �°� -��y deductible to be collected at time of material delivery. $--2 17;", initial total claim amount as of _ '57- / , q /20 ( This price is subject to supplements/adjustments. Roof work to be completed within 21 days of final insurance approval and mortgage endorsement* Property Owner is not intending to make payment from the procee s of a property and jcasualty insurance policy. ;INSURANCE ALLOWANCE AGREEMENT If so, homeowner must read and sign belo 1W0 agree to retain 1-Derful Roofing & Restoration (contractor) to repat0replace the damaged or entire portion of the property described on company's approval and payment to have said work completed. It is agreed that the contractor is em y - neet c of damage, the cost of the repair or replacement of the damage to the aboveproperty. t g nl upon the contractor obtaining my insurance empowered to contact m insurance carrier and to meet with their representative in order to neootiate the amount and may begin on a first in first out basis. Upon the insurance carrier agreement with the contractor and the down payment being made the work will be scheduled Checks shall be made savable to 1 Derful Roofing 8 Restoration C the event that the insurance he customer's tails r' negotiate in a fair and reasonable manner, the contractor shalt not be held liable and this agreement will be void The contractor will release the complete rite to the Commissioner of Insurance c the customer's reguest. Insured out at pocket expense will not exceed the insured (purchaser) policy deductible for the work agreed upon between the insurance carrier and the contractor. Insured also agrees to provide all the necessary documentation for the claim (including documentation to facilitate payment from insurance carrier and/or mortgage holder). The contractor reserves the right to file for Supplemental claims due to material and/or labor increases due to a storm environment or to insurance adjuster's mistakes, errors or omissions. o —r,Nally Uwe agre b gning above to all the contract conditions on both the front and back of this agreement City of V V heat 1C] COMMUNITY DEVELCiPMEN"T Building & inspection Services Division 7500 W. 291' Ave., Wheat Ridge, CO 80033 0ffice: 303-235-2855 ' Fax: 303-2317-8929 Inspection Line: 303-234-5933 Email: permits ci.wheatridge.co.us FOR OFFICE USE ONLY l Date: Add to Permit # 201706213 1 � Building Permit Revision Amendment ApplitCation — Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. — Property Address: 10535 W 32nd Ave Property Owner (please print): Caren Leaf & Lee Waldman Phone: 720-313-5312 Property Owner Email: Mailing Address: (if different than property address) Address: City, State; Zip: SubmittingCompany:1-derful Roofing & Restoration Contact Person: Colleen Jacobsen Contractor: 1-derful Roofnu & Restoration Contractors City license #: 070171 Phone: 303-984-7663 Contractor E-mail Address: lderfulcolleen@gmail.com Phone: 303-984-7663 Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. if revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour — 2 hour minimum). Description of revised/amended work: Add re -deck 24 Sqs. Sq. FULF Amps Btu's Squares 24 Gallons Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) 3,600.00 OWNEWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRrNT NAIME. Colleen. Jacobsen ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: SIGNATURE: l�`�' �✓ PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY DATE:09/057;1 OCCUPANCY CLASSIFICATION: 8 I� Building Division Valuation: $ I i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: y a G- r,__•^ n I Job Address: I c S 3 S L"j -�g Permit Number: --a o , -7 o & a. , -3 ❑ No one available for inspection: Time g =" 1 �M PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date:—C) /a a f 7 Inspector: --r--b DO NOT REMOVE THIS NOTICE ► e City of Wheat Ridge Residential Roofing PERMIT - 201706213 PERMIT NO: 201706213 ISSUED: 08/16/2017 JOB ADDRESS: 10535 W 32nd AVE EXPIRES: 08/16/2018 JOB DESCRIPTION: Residential Re -roof to install Atlas Pinnacle asphalt shingles - 24 sq *** CONTACTS *** OWNER (303)733-5770 LEE WALDMAN SUB (303)984-7663 Judy Antener 070171 1-DERFUL ROOF & RESTORATION *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION:. 7,200.00 FEES Total Valuation 0.00 Use Tax 151.20 Permit Fee 172.60 ** TOTAL ** 323.80 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge e Residential Roofing PERMIT - 201706213 PERMIT NO: 201706213 ISSUED: 08/16/2017 JOB ADDRESS: 10535 W 32nd AVE EXPIRES: 08/16/2018 JOB DESCRIPTION: Residential Re -roof to install Atlas Pinnacle asphalt shingles - 24 sq I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attesthat I am legally authorized to include all entities named within is document as parties to the work to be perto d and that all work t e performed ' disclosed in this document and/or, ' s' acco panying approved plans and specifications. Signature of OWNER or ONTRACTOR (Circle one) Date 1. This permit was issued ,based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpernrt fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or„ granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or npytorrdinnaru�e.�egul 'on f this jurisdiction. Approval of work is subject to field inspection. a Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz 20(7D V 'V From: no-reply@ci.wheatridge.co.us Sent: Monday, August 14, 2017 3:52 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Follow Up Flag: Follow up Flag Status: Completed Categories: Danny C3 ^' J Residential Roofing Permit Application C.s For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 10535 W 32nd Ave Property Owner Name Caren Leaf and Lee Waldman 217 J'" This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in c� the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if o your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 10535 W 32nd Ave Property Owner Name Caren Leaf and Lee Waldman 217 Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract 720-313-5312 Field not completed. Yes 17-0156 Leaf- Waldman.pdf CONTRACTOR INFORMATION Contractor Business 1-derful Roofing & Restoration Name Contractor's License 070171 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) 303-984-7663 9858 W Girton Dr Contractor Email Address 1derfulcolleen@gmail.com Retype Contractor Email Address DESCRIPTION OF WORK 1 derfulcolleen@gmail.com TOTAL SQUARES of 24 / the entire scope of work: Project Value (contract value or cost of ALL 7200.00 materials and labor) 218 Are you re -decking the roof? Does the scope of the project include a flat roof (less than 2:12 pitch)? Does the scope of the project include a pitched roof (2:12 or greater pitch)? How many squares are part of the pitched roof? Describe the roofing materials for the pitched roof: Type of material for the pitched roof: Provide any additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) No No Yes 24 Atlas Pinnacle Pristine LLT Asphalt Re -Roof House t/o existing shingles and replace with Atlas Pinnacle SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit 219 has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Colleen Jacobsen Email not displaying correctly? View it in your browser. 220 9858 W. Girton Drive Lakewood, CO 80227 Proposal Date: ��,/ Phone: 303-984-ROOF(7663) - D E R F U LThis proposal may be withdrawn by 1-Derful Fax: 855-696-7776 Roofing & Restoration if not accepted within 30 ROOFING & RESTORATION days from the above date. PROPOSAL FOR: �� Name: �/tf �iyicW�y SUBMITTED BY: 1 -DER UL ROOFING &RESTORATION Job Address o j j 1-Derful Rep: S' .� .mac City, State, Zip: ����---�—�i9 Cell Phone: Phone: Insurance Company: Adjustor information: ,�©3���> —6e6C�� Mailing Address: Policy Number: (If Different} _ (;i Email Address: Claim Number: Q t -0 7!7x-3 3� f-2. Best way to contact: _Tear Off and eaves are open or closed. _ u Gutters: Inspect Decking: Deteriorat d :existing decking color Outlet replaced at cost of$ Per Sq. Ft. Homeowner ❑ Siding: will be notified if any da tigedood is found during tear off. Install ice shield on eaves and in valley(s) -FFA � �p Ys Install drip edge ,2yc Color ❑Extra work Install underlayment _ 1,5� v Recover roof with year manufacturer warranty._ 9 ` Shingre manufacturer color ek 6 Nail every shingle d`LgOfj*- Install ridge style Install pipe ja s _I lead jacks61ash swamp cooler Step flash sidewalls AstepJ chimney step flash skylight 1-Derful Roofing & Restoration will provide general liability insurance 1 of at least $2,000,000 and Workers Compensation of at least $500,000 Clean up and haul of roofing debris Clean out gutters Magnetic sweep of surrounding area J Clean around landscaping All required Permits furnished by 1-Derful Roofing & Restoration to be reimbursed by Insurance Company 1-Derful Roofing & Restoration five year warranty on labor —� Current Ventilation Recommended � Decline recommendation on ventilation Date of Acceptance 1-Derful Roofing & Restoration Representativ Special instructio 1-derful Roofing and Restoration shall hold in trust any Payment received from you until 1-derful has delivered roofing materials at the site or has performed a majority of the roofing work on your property. $— %.1151 deductible to be collected at time of material delivery. $—,21 7 , initial total claim amount as of _ — / J/20 1 ?— This price is subject to supplements/adjustments. Roof work to be completed within 21 days of final insurance approval and mortgage endorsement' Property Owner is not intending to make payment from the procee s of a property and pasualty insurance policy. INSURANCE ALLOWANCE AGREEMENT If so, homeowner must read and sign bele !=e agree to retain 1-Derful Roofing & Restoration (contractor) to repair, 'replace the damaged or entire portion of the property described on ntra't con nl upon the contractor obtaining my insurance ofcompany'sdamage approval and payment to have said work completed. Itis agreed that the contractor is empowered to contact my insurance carrier and to meet with their representative in order to negotiate the amount of tlamage, the cost of the repair or replacement of the damage to the above property. Upon the insurance carrier agreement with the contractor and the down payment being made the work will be scheduled and may begin on a first in first out basis. Checks shall be made Payable to 1 Derful Roofing & Restoration In the event that the insurance carrier fails to negotiale in a fair and reasonable manner, the contractor shall not be held liable and this agreement will be void, The contractor will release the complete file to the Commissioner of Insurance at the customer's request, Insured out of pocket expense will not exceed the insured (purchaser) policy deductible for the work agreed upon between the insurance carrier and the contractor. Insured also agrees to provide all the necessary documentation for the claim (including documentation to facilitate payment from insurance carrier andlor mortgage holder). The contractor reserves the right to file for supplemental claims due to material andlor labor increases due to a storm environment or to insurance adjusters mistakes, errors or omissions. I we agreq going above to all the contract conditions on both the front and back of this agreement ► e City of Wheat Ridge Residential Roofing PERMIT - 201706213 PERMIT NO: 201706213 ISSUED: 08/16/2017 JOB ADDRESS: 10535 W 32nd AVE EXPIRES: 08/16/2018 JOB DESCRIPTION: Residential Re -roof to install Atlas Pinnacle asphalt shingles - 24 sq *** CONTACTS *** OWNER (303)733-5770 LEE WALDMAN SUB (303)984-7663 Judy Antener 070171 1-DERFUL ROOF & RESTORATION *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION:. 7,200.00 FEES Total Valuation 0.00 Use Tax 151.20 Permit Fee 172.60 ** TOTAL ** 323.80 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge e Residential Roofing PERMIT - 201706213 PERMIT NO: 201706213 ISSUED: 08/16/2017 JOB ADDRESS: 10535 W 32nd AVE EXPIRES: 08/16/2018 JOB DESCRIPTION: Residential Re -roof to install Atlas Pinnacle asphalt shingles - 24 sq I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attesthat I am legally authorized to include all entities named within is document as parties to the work to be perto d and that all work t e performed ' disclosed in this document and/or, ' s' acco panying approved plans and specifications. Signature of OWNER or ONTRACTOR (Circle one) Date 1. This permit was issued ,based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpernrt fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or„ granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or npytorrdinnaru�e.�egul 'on f this jurisdiction. Approval of work is subject to field inspection. a Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz 20(7D V 'V From: no-reply@ci.wheatridge.co.us Sent: Monday, August 14, 2017 3:52 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Follow Up Flag: Follow up Flag Status: Completed Categories: Danny C3 ^' J Residential Roofing Permit Application C.s For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 10535 W 32nd Ave Property Owner Name Caren Leaf and Lee Waldman 217 J'" This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in c� the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if o your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 10535 W 32nd Ave Property Owner Name Caren Leaf and Lee Waldman 217 Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract 720-313-5312 Field not completed. Yes 17-0156 Leaf- Waldman.pdf CONTRACTOR INFORMATION Contractor Business 1-derful Roofing & Restoration Name Contractor's License 070171 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) 303-984-7663 9858 W Girton Dr Contractor Email Address 1derfulcolleen@gmail.com Retype Contractor Email Address DESCRIPTION OF WORK 1 derfulcolleen@gmail.com TOTAL SQUARES of 24 / the entire scope of work: Project Value (contract value or cost of ALL 7200.00 materials and labor) 218 Are you re -decking the roof? Does the scope of the project include a flat roof (less than 2:12 pitch)? Does the scope of the project include a pitched roof (2:12 or greater pitch)? How many squares are part of the pitched roof? Describe the roofing materials for the pitched roof: Type of material for the pitched roof: Provide any additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) No No Yes 24 Atlas Pinnacle Pristine LLT Asphalt Re -Roof House t/o existing shingles and replace with Atlas Pinnacle SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit 219 has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Colleen Jacobsen Email not displaying correctly? View it in your browser. 220 9858 W. Girton Drive Lakewood, CO 80227 Proposal Date: ��,/ Phone: 303-984-ROOF(7663) - D E R F U LThis proposal may be withdrawn by 1-Derful Fax: 855-696-7776 Roofing & Restoration if not accepted within 30 ROOFING & RESTORATION days from the above date. PROPOSAL FOR: �� Name: �/tf �iyicW�y SUBMITTED BY: 1 -DER UL ROOFING &RESTORATION Job Address o j j 1-Derful Rep: S' .� .mac City, State, Zip: ����---�—�i9 Cell Phone: Phone: Insurance Company: Adjustor information: ,�©3���> —6e6C�� Mailing Address: Policy Number: (If Different} _ (;i Email Address: Claim Number: Q t -0 7!7x-3 3� f-2. Best way to contact: _Tear Off and eaves are open or closed. _ u Gutters: Inspect Decking: Deteriorat d :existing decking color Outlet replaced at cost of$ Per Sq. Ft. Homeowner ❑ Siding: will be notified if any da tigedood is found during tear off. Install ice shield on eaves and in valley(s) -FFA � �p Ys Install drip edge ,2yc Color ❑Extra work Install underlayment _ 1,5� v Recover roof with year manufacturer warranty._ 9 ` Shingre manufacturer color ek 6 Nail every shingle d`LgOfj*- Install ridge style Install pipe ja s _I lead jacks61ash swamp cooler Step flash sidewalls AstepJ chimney step flash skylight 1-Derful Roofing & Restoration will provide general liability insurance 1 of at least $2,000,000 and Workers Compensation of at least $500,000 Clean up and haul of roofing debris Clean out gutters Magnetic sweep of surrounding area J Clean around landscaping All required Permits furnished by 1-Derful Roofing & Restoration to be reimbursed by Insurance Company 1-Derful Roofing & Restoration five year warranty on labor —� Current Ventilation Recommended � Decline recommendation on ventilation Date of Acceptance 1-Derful Roofing & Restoration Representativ Special instructio 1-derful Roofing and Restoration shall hold in trust any Payment received from you until 1-derful has delivered roofing materials at the site or has performed a majority of the roofing work on your property. $— %.1151 deductible to be collected at time of material delivery. $—,21 7 , initial total claim amount as of _ — / J/20 1 ?— This price is subject to supplements/adjustments. Roof work to be completed within 21 days of final insurance approval and mortgage endorsement' Property Owner is not intending to make payment from the procee s of a property and pasualty insurance policy. INSURANCE ALLOWANCE AGREEMENT If so, homeowner must read and sign bele !=e agree to retain 1-Derful Roofing & Restoration (contractor) to repair, 'replace the damaged or entire portion of the property described on ntra't con nl upon the contractor obtaining my insurance ofcompany'sdamage approval and payment to have said work completed. Itis agreed that the contractor is empowered to contact my insurance carrier and to meet with their representative in order to negotiate the amount of tlamage, the cost of the repair or replacement of the damage to the above property. Upon the insurance carrier agreement with the contractor and the down payment being made the work will be scheduled and may begin on a first in first out basis. Checks shall be made Payable to 1 Derful Roofing & Restoration In the event that the insurance carrier fails to negotiale in a fair and reasonable manner, the contractor shall not be held liable and this agreement will be void, The contractor will release the complete file to the Commissioner of Insurance at the customer's request, Insured out of pocket expense will not exceed the insured (purchaser) policy deductible for the work agreed upon between the insurance carrier and the contractor. Insured also agrees to provide all the necessary documentation for the claim (including documentation to facilitate payment from insurance carrier andlor mortgage holder). The contractor reserves the right to file for supplemental claims due to material andlor labor increases due to a storm environment or to insurance adjusters mistakes, errors or omissions. I we agreq going above to all the contract conditions on both the front and back of this agreement 1 v- i CITY OF WHEAT RIDGE Building Inspection Division '- (303) 234-5933 Inspection line ��(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: .1, ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes N, o *Whencorrec ions, have been made, call for re -inspection at 303-234-5933 Date: 7 r Inspector: DO NOT REMOVE THIS NOTICE A I , A n_ i r,� n) -in n -i J TI J%YJ `�� WI ,, INSAEC 6N kECORD INSPECTION REQUEST LINE: (303) 234-5933 Occupancy/Type Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Mid -Roof Fire Inspection / Fire Protection Dist. Lath / Wall Tie Final Electrical j Rough Electric Final Plumbing Rough Plumbing/Gas Line Final Mechanical Rough Mechanical Roof Rough Framing Final Window/Doors Insulation Final Building Drywall Screw/ Nail NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. Final Electrical j Ri Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. "For Inspection Time Window Requests — Please email insptimereauest CCD.ci.wheatridge.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather e i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: & n1 Job Address: (V --,J `3 Nn It t' Permit Number: 4 6 ct "7 tl Y11 C7 i_ !►'1t' J, 'C ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: r Inspector: - DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Ez rL Job Address: /O. -3 i -4 v f Permit Number: j :o / ::� 6 6 i ' 711;,. S¢' S" i tip AJ tN t 41f 1 d `Q n i 7S P(- k Qg,[, - . f sr lgra C ice' J7 L Y'i� ❑ No one available for inspection: Time /O.' / � AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: 64 1 Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Solar PERMIT - 201700207 PERMIT NO: 201700207 ISSUED: 02/14/2017 JOB ADDRESS: 10535 W 32nd AVE EXPIRES: 02/14/2018 JOB DESCRIPTION: Install 4.42 kw roof mounted grid -tied solar PV system. *** CONTACTS *** OWNER (303)733-5770 LEE WALDMAN SUB (888)765-2489 Jared A Miller 110035 SolarCity Corporation *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT##: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,011.20 FEES Total Valuation 0.00 Residential Solar 500.00- ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** MM: Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thisernit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be perform atrall work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Si ture of OWNER or CONTRACTOR ircle one) Date This permit was issued base on a in ormation provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services 6. The issuance or granting of a permit shall not be construed to be a ap,plic#blq code or any ordmange or regulation of this jurisdiction. iit for, or an approval of, an violation of any provision of any roval of work is subject to field inspection. XM)vp% Signature of Chief Building OfficialDate REQUESTS MUST BE MADE BY 11:59PM ANY BU ESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of ]��Wh6at,ldge MCOMUNITY DEVELOPENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 as Building Permit Application �- *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** KU 1 Wk FOR OFFICE USE ONLY Date: p 2, Plan/Pennit # 210 ( ,1W 2 C) Plan Review Fee: f S&)/ U0 Property Address: 10535 W 32nd Ave, Wheat Ridge CO 80033 Property Owner (please print): Lee Waldman Phone: (720) 313-5312 Property Owner Email: Iwaldman3@gmail.com Mailing Address: (if different than property address) Address: Same as above City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Contractor: Solar City Contractors City License #: 110035 Contractor E-mail Address: tward@solarcity.com Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: 253-720-4461 Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT X OTHER (Describe) Solar PV (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Install a 4.42 kW roof -mounted grid -tied solar PV system Sq. FULF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) -6011.2 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. �—,� CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)W] I Justin Catlett Justin Catlett Dtal 017.0.09ned Justin Catlett Date: 2017.02.09 11:21:09 PRINT NAME: SIGNATURE: 07.00' DATE: 2/9/2017 DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: _ Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required Building Division Valuation: $ SoiarCity January 10, 2017 RE: Project/Job # 80010233 Project Address: AHJ SC Office Design Criteria: CERTIFICATION LETTER Waldman Residence 10535 W 32nd Ave Wheat Ridge, CO 80033 Wheat Ridge Denver - Applicable Codes = IRC 2012 / IBC 2012, ASCE 7-10, and 2012 NDS - Risk Category = II - Wind Speed = 135 mph, Exposure Category C, Partially/Fully Enclosed Method - Ground/Roof Snow Load = 30 psf (Unreduced) - MP1: 2x6 @ 24" OC, Roof DL = 7.5 psf, Roof LL/SL = 30 psf - MP3: 2x6 @ 24" OC, Roof DL = 7.5 psf, Roof LL/SL = 30 psf Version #64.8 - TBD RU Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.23116 < 0.4g and Seismic Design Category (SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure, with upgrades specified in the plans, directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. William A. Eldredge, P.E. Digitally signed by Professional Engineer William Eldredge Date: 2017.01.10 T: 888.765.2489 x58636 1603:40-05'00' email: weldredge@solarcity.com 3055 Clearview way San Mateo, CA 94402 T(650) 638 -1028 (888) SOL -CITY F (650) 638 -1029 solarcity.com d L, ,._n c, SolarCity. Version #64.8 - TBD RU HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware Hardware - Landscape Modules' Standoff Specifications X -X Spacing X -X Cantilever Y -Y Spacing Y -Y Cantilever Configuration Uplift DCR MPI 72" 24" 39" NA Staggered 56.9% M1133 72" 24" 39" NA Staggered 57.1% Portrait Hardware Hardware - Portrait Modules' Standoff Specifications X -X Spacing X -X Cantilever Y -Y Spacing Y -Y Cantilever Configuration Uplift DCR MPI 48" 19" 65" NA Staggered 63.2% MP3 48" 20" 65" NA Staggered 63.4% Structure Mounting Plane Framing Type Spacing Pitch Qualification Results Member Evaluation Results MP1 Stick Frame 24" O.C. 200 Member Analysis OK w/ Upgrades as Specified in Plans MP3 Stick Frame 24" O.C. 240 Member Analysis OK w/ Upgrades as Specified in Plans Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site. The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055 Clearview Way San Mateo, CA 94402 (650) 638 -1028 (868) SOL - CITY (650) 638 - 1029 solarcity.com STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP1 Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (Ct) (IS) p9 ; Ce=0.9, Ct=1.1, I,=1.0 Member Design Summary (per NDS) Governing Load Comb CD CL (+) I CL (-) i CF Cr D + S 1.15 1.00 1 0.78 1 1 1.15 Member Analysis Results Summary Member Properties Summary Max Moment @ Lcation Capacity DCR Result BendingStress (psi) MPl Roof Pitch Horizontal Member Spans Overhang 2.16 ft Rafter Properties Actual W 1.50" Roof System Properties Span 1 9.75 ft Actual D 5.50" Number of Spans w/o Overhang) 2 Span 2 4.03 ft Nominal Yes Roofing Material Comp Roof San 3 1.06 A in^2 8.25 Re -Roof No Span 4 x Sx (in.^3) 7.56 Plywood Sheathing No San 5 30.0 psf Ix in^4 20.80 Board Sheathing Solid -Sheathing Total Rake Span 16.96 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 1.67 ft Wood Species DF Ceiling Finish 1/2" Gypsum Board PV 1 End 13.08 ft Wood Grade Construction Rafter Slope 200 PV 2 Start Fb(psi) 1,000 Rafter Spacing 24" O.C. PV 2 End Fv (psi) 180 Top Lat Bracing Full PV 3 Start E (psi) 1,500,000 Bot Lat Bracing At Supports PV 3 End E-min(psi) 550,000 Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (Ct) (IS) p9 ; Ce=0.9, Ct=1.1, I,=1.0 Member Design Summary (per NDS) Governing Load Comb CD CL (+) I CL (-) i CF Cr D + S 1.15 1.00 1 0.78 1 1 1.15 Member Analysis Results Summary Member Loading Summary Max Moment @ Lcation Capacity DCR Result BendingStress (psi) -1,070 i_101.9 ft -1,033 1.04 Pass Roof Pitch 5/12 Initial Pitch Adjust Non -PV Areas PV Areas Roof Dead Load DL 7.5 psf x 1.06 8.0 psf 8.0 psf PV Dead Load PV -DL 3.0 psf x 1.06 3.2 psf Roof Live Load RLL 20.0 psf x 0.98 19.5 psf Live/Snow Load LL/SLI•Z 30.0 psf X1 1XI 30.0 psf 30.0 psf Total Load(Governing LC TL 1 1 38.0 psf 1 41.2 psf Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (Ct) (IS) p9 ; Ce=0.9, Ct=1.1, I,=1.0 Member Design Summary (per NDS) Governing Load Comb CD CL (+) I CL (-) i CF Cr D + S 1.15 1.00 1 0.78 1 1 1.15 Member Analysis Results Summary Governing Analysis Max Moment @ Lcation Capacity DCR Result BendingStress (psi) -1,070 i_101.9 ft -1,033 1.04 Pass ZEP HARDWARE DESIGN CALCULATIONS - MP1 Mounting Plane Information Roofing Material IBC 2012 Comp Roof Table 30.3-1 Roof Slope Rafter Spacing KA 200 24" O.C. Section 26.8 Framing Type / Direction PV System Type Zep System Type Standoff Attachment Hardware V-Ult Y -Y Rafters SolarCity SleekMountTM ZS Comp Comp Mount SRV Fig. 1609A Spanning Vents I No Section 26.7 Roof Style Wind Design Criteria Wind Design Code IBC 2012 ASCE 7-10 Table 30.3-1 Wind Design Method KA Partially/Fully Enclosed Method Section 26.8 Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Exposure Category I C Section 26.7 Roof Style qh Gable/Hip Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 30.3-1 Topographic Factor KA 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Trib Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) Equation 30.3-1 3.0 psf 33.7 psf T -actual Wind Pressure Ext. Pressure Coefficient U GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GCp (Down) 0.45 Fig. 30.4-2A/B/C-SA/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure Up P(UP) -29.5 psf Wind Pressure Down dam 16.0 psf ALLOWABLE STANDOFF SPACINGS X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -312 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 56.9% X -Direction Y -Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -346 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 63.2% STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP3 Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-21 2. pf = 0.7 (Ce) (Ct) (IS) p9 ; Ce=0.9, Ct=1.1, I5=1.0 Member Design Summary (per NDS) Governing Load Comb CD CL (+) Cl_ (-) I CF Cr D + S 1.15 1.00 1 0.80 1 1 1.15 Member Analysis Results Summary Member Properties Summary DCR Result Bending Stress(psi) -906 11.2 It -1,062 MP3 6/12 Horizontal Member Spans Overhang 1 2.16 It Rafter Properties Actual W 1.50" Roof System Properties San 1 9.04 It Actual D 5.50" Number of Spans w/o Overhang) 2 Span 2 4.06 ft Nominal Yes Roofing Material Comp Roof San 3 Roof Live Load A in^2 8.25 Re -Roof No Span 4 Live/Snow Load Sx (in.^3) 7.56 PI ood Sheathing No San 5 Total Load(Governing LC Ix(in ^4 20.80 Board Sheathing Solid -Sheathing Total Rake Span 16.70 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 1.33 ft Wood Species DF Ceiling Finish 1/2" Gypsum Board PV 1 End 12.17 ft Wood Grade Construction Rafter Slope 240 PV 2 Start Fb (psi) 1,000 Rafter Spacing 24" O.C. PV 2 End Fv (psi) 180 Top Lat Bracing Full PV 3 Start E (psi) 1,500,000 Bot Lat Bracing At Supports PV 3 End E-min(psi) 550,000 Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-21 2. pf = 0.7 (Ce) (Ct) (IS) p9 ; Ce=0.9, Ct=1.1, I5=1.0 Member Design Summary (per NDS) Governing Load Comb CD CL (+) Cl_ (-) I CF Cr D + S 1.15 1.00 1 0.80 1 1 1.15 Member Analysis Results Summary Member Loading Summary DCR Result Bending Stress(psi) -906 11.2 It -1,062 Roof Pitch 6/12 Initial Pitch Must Non -PV Areas PV Areas Roof Dead Load DL 7.5 psf x 1.09 8.2 psf 8.2 psf PV Dead Load PV -DL 3.0 psf x 1.09 3.3 psf Roof Live Load RLL 20.0 psf x 0.93 18.5 psf Live/Snow Load LL/SL1,2 30.0 psf X1 j x 1 30.0 psf 30.0 psf Total Load(Governing LC TL 1 1 38.2 psf 1 41.5 psf Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-21 2. pf = 0.7 (Ce) (Ct) (IS) p9 ; Ce=0.9, Ct=1.1, I5=1.0 Member Design Summary (per NDS) Governing Load Comb CD CL (+) Cl_ (-) I CF Cr D + S 1.15 1.00 1 0.80 1 1 1.15 Member Analysis Results Summary Governing Analysis Max Moment @ Location Capacity DCR Result Bending Stress(psi) -906 11.2 It -1,062 0.85 1 Pass ZEP HARDWARE DESIGN CALCULATIONS - MP3 Mounting Plane Information Roofing Material IBC 2012 Comp Roof Table 30.3-1 Roof Slope Rafter Spacing K�t 240 24" O.C. Section 26.8 Framing Type / Direction PV System Type Zep System Type Standoff Attachment Hardware V-Ult Y -Y Rafters SolarCity SleekMountTM ZS Comp Como Mount SRV Fig. 1609A Spanning Vents I No Section 26.7 Roof Style Wind Design Criteria Wind Design Code IBC 2012 ASCE 7-10 Table 30.3-1 Wind Design Method K�t Partially/Fully Enclosed Method Section 26.8 Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Exposure Category I C Section 26.7 Roof Style qh Gable/Hip Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 30.3-1 Topographic Factor K�t 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Trib Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) Equation 30.3-1 3.0 psf 33.7 psf T -actual Wind Pressure Ext. Pressure Coefficient U GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GCp (Down) 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure Up p „ -29.5 psf Wind Pressure Down down 16.0 psf ALLOWABLE STANDOFF SPACINGS X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -313 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 57.1% X -Direction Y -Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -347 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 63.4% Photovoltaic Array 605.11.3.2.1 Residential buildings with hip roof lay outs. Panels / modules installed on residential buildings with hip roof lay outs shall be located in a manner that provide a 3 foot- wide clear pathway from the eave to the ridge on each roof slope where panels and modular are located. The access pathway shall be located at a structurally strong location on the building capable of supporting the live load of the fire fighters accessing the roof. 60511.3.2.2 Residential buildings with a single ridge. Panels/modular installed on residential buildings with a single ridge shall be located in a manner that provides two, 3 foot —wide access pathways from the eave to the ridge on each roof slope where panels /modular are located. 605.11.3.2.3 Residential buildings with roof hips and valleys. Panels/ modular installed on residential buildings with roofs hips and valleys shall be located no closer than 18 inches to a hip or a valley where panels or modular are to be placed on both sides of a hip or valley. Where panels are to be located on only one side of the hip or valley that is of equal length the panels shall be permitted to be placed directly adjacent to the hip or valley. 605.11.3.2.4. Residential building smoke ventilation. Panels / modular installed on residential buildings shall be located no higher than 3 feet below the ridge in order to allow for fire department smoke ventilation operations. Exception: This requirement shall not apply to roofs with slopes of 2 unit's vertical in 12 unit's horizontal (2:12) or less ABBREVIATIONS I ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. LICENSE GENERAL NOTES TYPE EC # 8041 1. ALL WORK SHALL COMPLY WITH THE 2012 IBC AND 2012 IRC. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE. MODULE GROUNDING METHOD: * AHJ: Wheat Ridge UTILITY: XCEL Energy (CO) CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION 1MTH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -80010233 MOUNTING SYSTEM: ZS Comb V4 w Flashina—Insert (17) REC # REC260PEZ INVERTER: Delta # Solivia 5.2 TL 00 PREMISE OWNER: LEE WALDMAN 10535 W 32ND AVE WHEAT RIDGE, CO 80033 VICINITY MAP INDEX PV1 COVER SHEET PV2 SITE PLAN d PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM Cutsheets Attached Lee Waldman RESIDENCE 4.42 KW PV ARRAY PAGE NAME: COVER SHEET REV BY DATE COMMENTS REV A I NAME DATE COMMENTS Duke Tang SHEET: REV: DATE: PV 1 1/10/2017 solarCit . 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solorcity.com (62*Z-99L) ALD-IOS L IWO V L n d 6ZOt-Sf:9 (059):d 9ZOL-8f9 (059) 1 ZOW YD '-}ow UDS 31YO ;A38 '133HS ADM ■a!koaD 590£ Al!:)jeloS,, 6uDl 9�n0 31063 S ,9T S T 0 3 M T = „8/T :aleDS N Nbrld DES 03HSVO SI 1N3YVdIn03 2Ol d1Nl ` L —'-J 0321 3NV S1N3A 9N13n002d 1V3H 33N33/31V9 dOIN31N1 NO Nna 11nONO3 80IN31X3 NO NnN lInONO3 SNOUV301 3300NV1S NMOO1nHS OIdVN Osa d313W W31S,S Ad 031V31030 O S338VI 9NINNVM ?8 d31N33 OVOI 0 S338VI V 13NVd NOI1noiaLSlO OO S138VI )? X08 d3N18W03/NOLLONnf 00 Oe S13OVI 9NINdVM N 133NN03S10 3V ov SI3OVI 9NINdVM )R 133NN00S10 DO Ea 1001 S130VI 9NINdVM 2R 03S10 30 031Vd931N1 /M 631b3ANl NI 80 3IOHM NI 03SO105G 38 I38VI 9NINM 2R n 3W l,llllln (3) O UN=lJ=l i AJOIS T :,kdO1S albul4S tlwO3 :IVld3IVW 0LZ:H1nWIZV ,1Vd21V OZZ:H1nWIZV EdW bZ :H311d ,IVMV bZ :H011d IS T :,KdOlS albul4S dwo3 :IVRd1VW 08T :H1nhlZV kV2 dV 08T :H1nINIZV TdW OZ :H011d ),Vd6V OZ :H311d NVId 311S 3MVN 3DYd �dddd Ad Mei ZV*t 30N3aIS3d UDWPIDM aa3 H008 00 `3001d lb'3HM ]AV ONN M 5 501 NVhMVM 331 asnOH 40 IuOJJ I1 Z S DIAIIOs # D}la0 'DNI :83183ANI A108YIOS d0 NOISSIY183d '10ridin03 N31110 3HL 1nOHIM UDWIOS Z3d09Z)3d # 03d W) 3ALL0363N 3HL ID 3sn ONV 3IVS 311 S31nO0N HIM NOLL03NNOO NI 1d3DX3 'NOLLVZIW080 M dw03 111l1VHSO 01 18ON 4aasul-6uiysD13 M SZ NI 80 3IOHM NI 03SO105G 38 TN31SAS DNUNnOMI "DNI AIDNVIOS icMX3 3NOANV 10 IU3N38 2N 80f 00 HZ01008-81f38Mn 33 O35n 38 N IIVHS 43NM1NOD NI3213H NOLLVW2p3NI Ni - lVLLN3OliN00 ItlNp/S�, 90t1S00 �p�'�P7011'�y�on Aldo wunionbas ao:A (33NDIS T it3dVYVIS .00,50- ZZ:tl0:9 L O l' LO'L LOZ :alea a6pa1p13 we!II!M A9 paubis Allel!bla (-C-��SIDE VIEW OF MPI NTS 2x6 Purlin 'x4 Struts MP3 X -SPACING X CANTILEVER Y -SPACING Y -CANTILEVER I NOTES LANDSCAPE 72" 24" 39" 65" 0" STAGGERED 0" PORTRAIT 48" 20" RAFTER C.I. 2x6 @ 24" OC 2x6 @16" OC ROOF AZI 270 PITCH 24 STORIES: 1 ARRAY AZI 270 PITCH 24 Comp Shingle - Solid Sheathing X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP MOUNTING BLOCK ZEP FLASHING INSERT (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG SCREW (2-1/2" EMBED, MIN) (E) RAFTER (N) A34 Clip STAMPED & SIGNED FOR STRUCTURAL ONLY CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION MATH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. S1 STANDOFF JOB NUMBER: JB -80010233 00 MOUNTING SYSTEM: ZS Comp V4 w Flashinq—Insert (17) REC # REC260PEZ INVERTER: Delta # Solivia 5.2 TL THIS STRUCTURE WILL RECEIVE A STRUT UPGRADE. THIS STRUCTURE WILL RECEIVE A NEW PURLIN AND STRUTS. r oo L,cHOLD•'•• S 0051106 d: �60 INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. ATTACH FLASHING INSERT TO (2) MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE ROOF PENETRATION. INSTALL LEVELING FOOT ON TOP (4) OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. LEE WALDMAN 10535 W 32ND AVE WHEAT RIDGE, CO 80033 OA SIDE VIEW OF MP1 NTS MP1 X -SPACING X -CANTILEVER Y -CANTILEVER NOTES LANDSCAPE 72" 24" -Y-SPACING 39" 65" O" STAGGERED 0" PORTRAIT 48" 19" RAFTER 2x6 @ 24" OC C.j. 2x6 @16" OC ROOF AZI 180 PITCH 20 STORIES: 1 ARRAY AZI 180 PITCH 20 Comp Shingle - Solid Sheathing X ANDY ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. (E) RAFTER ATTACHED TO (N) STRUT WITH (3) SIMPSON SDW-22300 SCREWS (N) PURLIN ATTACHED TO (N) STRUT WITH (3) 10d COMMON NAILS (N) CLEAT NAILED TO (N) STRUT WITH (3) 10d COMMON NAILS (N) STRUTS (N) A34 CLIP W/ (8) 8d x 1.5" NAILS NOTE: DF #2 UPGRADE LUMBER NOTE: (N) STRUTS SHOULD BE INSTALLED 45' FROM VERTICAL ' MAX: (E) LBW 45' 2x6 Purlin x4 Struts (N) A34 Clip THIS STRUCTURE WILL RECEIVE A STRUT UPGRADE. THIS STRUCTURE WILL RECEIVE A NEW PURLIN AND STRUTS. INSTALLATION NOTES: 1. INSTALL (N) STRUTS FLUSH TO (E) RAFTERS WITH (3) SIMPSON SCREWS AND PURLIN WITH (3) 10d COMMON NAILS. 2. INSTALL (N) CLEATS TO THE (N) STRUTS DIRECTLY BELOW AND FLUSH WITH THE (N) PURLIN. 3. INSTALL (N) A34 CLIP WITH (8) 8d (0.131") X 1.5" NAILS. ADD (N) STRUTS AS NECESSARY TO ENSURE THAT THE (N) PURLIN NEVER HAS A CLEAR SPAN GREATER THAN 4'. U 1 NEW STRUTS AND PURLIN FRONT VIEW IESCRIPTION: DESIGN: Lee Waldman RESIDENCE Duke Tang '\`/. SolarCity. 4.42 KW PV ARRAY oo PAGE NAME: STRUCTURAL VIEWS 3055 Clea view Way SHEET-. REV: DATE: Sm Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 PV 3 1/10/2017 (888)—SOL—CITY (765-2489) www.solarcity.com Alp-DS9):l 68) umr6ZOI- t HOZ/0 �/ � V n d SNOLL'vin0�d0 l�l�df1 �l Z"5 DInI�Os D}�a0 :a31a3AN1 'DNI kilDWOS O NOISSIna3d 9 (0 9):J U01 6201-8£9 (OS6)�3 8101-8£9 (CS9)�1 ZADM VD '-ion ws 31r0 Ma 133Hs anrN 3Ord N3111W 3H1 1nOHJA '1N3ndln03 kII08VIOS 3%03dS38 3H1 30 3Sn ONr 3lrS 3H1 Zld09Z03d # 032 (L l) ADM "amp SSO£ H008 OO 1001 1d3HM Ad Mei Ztb 3Ad aNZ� M 5�901 531noon 1 -UM N01103NNOD NI 1d30X3 'NOILrZINr0a0 S1N31d103a 3H1 301S1nO S83H10 01 lard NIDaO 3100 N103SO10SIO 39 It 1U3N338 }�asu�-6uiysDld M �nON o SZ Aj!:)jejoS.���,lb'NNb' AM SOOHILMOn NOANr 0 6uol aIn4 30NMS3� uoWplpM aaj NdWaIdM 3]] Nd3H NOtna03NI 31-11 - IVUN301ANOD 31-11 8oJ tl00 M[009—or'yGNnNB :NDIS30 :NORdWS30 :83WO 3SIn3d SN011dlfloivo ivniond1S dOd IIADVd 3lddddIS ]IS S Noi-Lvi nDIVD 1UI]d n GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: MC204OB1150RJBC Inv 1: DC Ungrounded INV 1 — (1 )Delta # Solivia 5.2 TL LABEL: A. — (17)REC REC26OPEZ 6odule; TYPE EC # 8041 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 45 359 291 Inverter;5200W, 240V, 97.5%, Zlgbee, PLC PV 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled INV 2 Underground Service Entrance Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 150A MAIN SERVICE PANEL Delta E 150A/2P MAIN CIRCUIT BREAKER Inverter 1 IND MILBANK CUTLER-HAMMER 4 �A T 150A/2P Meter Socket Disconnect 5 Delta DC- Solivia 5.2 TL MP3: 1x7- (E) LOADS B /7I� C Li zaov F-–––––––––––—––– –– – – – – ––-----------_ EGc _ - - - - - - - - 13 30A/2P t -- n -- GND ------------------------- N EGCI --- GEC Dc- DC+ – – – li DC. I 3 2 i DC+ I C- MPT: 1x10 B GND EGC– G __ ----------------------- –------t� –––––––––– I I (1 ) Conduit Kit; 3/4' EMT – N I I EGC/GEC – z z GEC TO 120/240V I I SINGLE PHASE UTILITY SERVICE I I I I I I I I I I Voc* = MAX VOC AT MIN TEMP O1(1)SIEMENS 10230 PV BACKFEED BREAKER 1 Breaker, 30A/2P, 2 Spaces B (1)MILBANK 1 U4801–XL-5T9 Meter Socket; 200A, #6-350, Ringless AC A (2)Delta Solivia Smart RSS Rapid Shutdown, 60OV, 20A, NEMA 4X, MC4 nd ( 1) AWG 16, Solid Bare Copper DC –(2)G5 ;d RoQ 5%8 x 8, Copper –(3)MILBANK # K4977–INT Load–Side Tap Connector, IOOA, 112 – 1/0 AWG –(1) (ARRAY GROUND ELECTRODE: LOCATE (N) GROUND ROD PER NEC 690.47(D) TO GROUND THE ARRAY. CONNE (1)CUTLER–HAMMER / DG221URB Disconnect; 30A, 24OVac, Non–Fusible, NEMA 3R A SEPARATE (N) 16 GEC FROM THE ELECTRICALLY BONDED ARRAY FRAME TO THE (N) GROUND ELECTRODE. ! J – (1) CUTLER–HAMMER y DG03ONB THE (N) GEC SHALL BE KEPT SEPARATE FROM ALL OTHER NON–CURRENT CARRYING METAL PARTS. Ground/Neutral it; 30A, General Duty (DG) OIsh 5 (1 )AWG 110, THWN-2, Black (1 )AWG 110, THWN-2, Red 2 ANG 110, PV Wre, 600V, 81ack Voc* = 435.15 VDC Isc = 9.01 ADC O g (1 )AWG 110, Solid Bare Copper EGC Vmp = 307 VDC Imp= 8.5 ADC (2)AwG 110, PV Nrre, 600V, Blaak Voc* = 304.61 VDC Isc = 9.01 ADC O (1 )AWG 110, THHN/THWN-2, Green EGC Vmp = 214.9 VDC Imp= 8.5 ADC LL LL (1 )AWG /10, THWN-2, White NEUTRAL Vmp = 240 VAC Imp= 21.6 AAC (1)Conduit Kit; 3/4' EMT I (1 ) Conduit Kit; 3/4' EMT – (1 )AWG 18, THWN-2, Green EGC/GEC – (1)Conduit Kit; 3/4" EMT ® (2) ANG 110, PV Wire, 60OV, Black Voc* = 304.61 VDC Isc = 9.01 4 (1 )AWG 110, Solid Bare Copper EGC Vmp = 214.9 VDC Imp= 8.5 ADC ADC (2) AWG 110, PV Wire, 60OV, Black Voc* = 435.15 VDC Isc = 9.01 ADC 1 O (1 ) AWG 110, THHN/THWN-2, Green EGC Vmp = 307 VDC Imp= 8.5 ADC (1 ) Conduit Kit; 3/4' EMT (1 ) Conduit Kit; 3/4" EMT CONFIDENTIAL THE INFORMATION HEREIN –\\� H CONTAINED SHALL NOT USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBER: JB-80010233 0 0 PREMISE OWNER: LEE WALDMAN DESCRIPTION: Lee Waldman RESIDENCE DESIGN: Duke Tang ;eOlar�I}" ��� J l.�/ ; MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 10535 W 32ND AVE 4.42 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS WHEAT RIDGE, CO 80033 MODULES (17) REC # REC260PEZ 3055 Clearview Way Son Mateo, CA 94402 ORGANIZATION, EX IN N N1 THE SALE AND USE OF THE RESPECTIVE SHEET: REV: DATE: SOLARCITY EQUIPMENT, WITHOUT THE WRITTENPAGE PERMISSION OF SOLARCITY INC. NAME THREE LINE DIAGRAM PV 5 1/10/2017 T:(650) 638-1028 F:(650) 638-1029 (888)-SOL-CITY(765-2489) www.solarcity.com INVERTER: Delta # Solivia 5.2 TL „=-A,10,D,S'"A (acti-Sec) ua-los-case) 6ZOl ZOtr6 VO '-ID DS (099)'.l ADM AW"a SSoe LLOZ/OL/L 9 Ad 31VO ,m U3HS SNOIIVIAO�d0 ad0� lVONi0T3 3mYN 39Vd I \I\I NON 00 `30M 1b3HM ^daOd nd MA Z� V ^V r9 I �/ \ V QNZ� M �L 7O b 30NMS3d UDWPloM @91 Nb'Walb'M 33l �NOadRpS3a �213iN0 3s -/'[old 11 Z*S DIA110S # Dii9a 3f312[ U 'ON] ALD8Y= -40 NOISSU'ROd N3LLRIM 3H1 1nOH11M '1N3140M3 A113WIDS 3nu33dS38 3H1 30 3sn arra 3Ns 3HI HIM S.LN31dD:Fd 3H1ONI 30 �� 3RL0 01 ISU NI ao 310HM NI 03SOMSIO 38 11 IIVHS 8ON "ONI AlDSVIOS IcMX3 3NOANV � 1LDN38 3H1 8o3 a3sn 38 ION IIVHS 03NrolNOO N083H NOLLV1'WJNI 3H1 — IVLLN30UNDO Z3dO9Z03d # 038 (LI) 53100D1 �� ��� I 1:,,;� Ai!:)jelos, ,�\ }.Iasul-6uiysD13 M M dwoOSZ :KUSkS 9NILNnOR 6uD1 a�{nd xg630 (`(` I 00 L L ZO l OOH—o r :aBWN ea' V * pe03 ON pue 6Lnle9H 'g yn * peo3 palelnoleo lelauaE) to wnS PeO3 IEIol yn * peol 6wu04lpu00-3ly pue 6u11e9H xelN seoeumd DIJ10913 10 wnS luawdlnb3 31y to wnS yn I 3aNea38 peo3 to lueoied OO L [le) pasn aq Ilegs gloq lou lnq '6ulleaq-coeds 3o buluolllpum-ne to peol paloauuoo 3a63el eqi (S)£8'OZZ 03N VA * (peol O/y-uou) peol palelnoleo le3auaC) I 1* %Ot, le peol 10 3apulewab 0008 1 %00 L le peol to ynN 8 lsn3 yn * (PeOI O/y-uou) peo3 le3auac) lelol „sjaleaq Jalenn [pue] llnono L4oue3q AGpunel eql of paloauuoo lou a3e legl sjaAjp saglolo sllun bulN000 palunow-3alunoo 'suano palunow-Ilene 'sabueH seouelldde 11V (£)(9)£8'OZZ 03N OOST T OOST T * * yn slmono woo3L4le8 spno<) tipune3 slmon:D eouellddy IIewS '(Z)(:D) PUB (L)(0) L L'0 LZ ul p93an00 linono youe3q kpunel goeo pue llno3lo goue3q eouelldde-hews aiedwe-OZ 'anon -Z Lloea 30l yA 009L (Z)(S)£8'0ZZ D3N * VA * l] (4 bsMn£) easy 3001-4 -ZL'OZZ Aq poulwialop se z4)sa3adwe-ll0n g '.. le saloeldao93 asn-le3auab pue bu114611 1e3auDS 4)(S)£8'OZZ 03N %Ob le peol 10 39pul8w9H '%001 le peol 10 VAN 8 1s113 ... speol ... bugslxe Sol pasn aq llegs sa6elueo3ad bulnnollol aq_L ... Alloedeo lualoLps JOS[ ... 801AJas 6ugslxa ayl ll aulLwalap of ... -;lull bulllanna bullslx3„ (S)£8'OZZ 03N O e uo!sJan uolleln:)le:) peon lelluaplsab - £8'OZZ 33N 3aNea38 I peo3 SNouyinDiyD IVDI8313 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 10535 W 32nd Ave INVERTER AND DC DISCONNECT AC DISCONNECT UTILITY SERVICE --———--———————————-------� l SOLAR PHOTOVOLTAIC ARRAY(S— L -------------------------- -------------------- — J PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER. J B-80010233 MOUNTING SYSTEM: ZS Como V4 w Flashina—Insert (17) REC # REC26OPEZ INVERTER: Delta # Solivia 5.2 TL JB -80010233-00 00 PREMISE DOER: LEE WALDMAN 10535 W 32ND AVE WHEAT RIDGE, CO 80033 Lee Waldman RESIDENCE 4.42 KW PV ARRAY PAGE NAME:- SITE AMESITE PLAN PLACARD Duke Tang SHEET: REV: DATE: PV 7 1/10/2017 ;SolarCity t 3055 Cleorview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com 6fM —Y4.» Mrn� 11110jelos"i"!!, .3NIA113ALL03 3 NOISSIo 3d NONV T 3H1 1nOFt11M OLL0 NNO3 NI Idd10S �' (68bZ-59L),UI�-IOS-(888) 3A1133dS321 3H1 30 3Sf1 ONV 3lVS 3H1 H1W1 NO1133NN03 NI 1433X3 6ZOT-8£9 (0S9):d8Z0i-8£9 %9)1laS lapel 'NO(1VZINVO60 S,1N31dl338 3H1 301s1f10 S2GH10 01 121Vd NI 80 3100 NI Aem �w of 03SO-OSIC 38 lI -nVHS 8ON "3NI KIDWOS 1d33X3 MANY 30 IU3N38 3H1 AeM Main�eal� SSO£ lok--ol 2103 03Sf1 38 ION IIVHS 03Nro1NO3 NI3213H NOI1VW2103NI 3H1 - lVf1N301iNO3 uogoauuooJalul;o lulod :(IOd) jalaW 4nn :(W) JaluaO peol :(Ol) loauuooslQ Oa paleJ6alul gllM Jal3anul :(AN0 linpuoO un�j joualul :(OI) l3auuoosiQ Oa :(Oa) hued uoilnquls!U :(4) xo8 lau!gwoO :(90) l!npuo0 :(0) loauuoosla OV :(:DV) 030NnM19Nn SI ?IAI2J3nNI N3HM 43Sf1 38 o (4)5£'069 03N :apoO gad (ANO (Oa) : uolleool lagel V'9'b9'069 O3N :apoO gad (IOd) :uolleool lagel GE1103NNOO W 31SAS OI`d17lOAOlOHd (OL 6'069 03N :apoO Jed (IOd) (OV) :uogeoollagel t,9'069 O3N :apoO gad (IOd) (OV) uolleool lagel (OV) uogeoollagel Z'O'VV069 O3 WOO gad (IOd) (OV) :uolleool lagel 09'069 O3N :apoO gad (ANO (Oa) uolleool lagel Z'O'V6'069 03N WOO gad (ANI) (O4) :uoileool lagel £'3' 6£069 DEIN WOO gad (0) uoileool lapel N31SAS OI`dl-10AOlOHd HIGH PERFORMANCE SOLAR PANELS REC PEAK ENERGY REC Peak Energy? -Link Series solar panels are the perfect choice for building solar systems that combine long lasting product quality with reliable power output. REC combines high quality design and manufacturing standards to produce high- performance solar panels with uncompromising quality. RETE PEAK ENERGY ZLINK SERIEG _ 67.5 *u.l c 39.02 47.24 0.47 - N P All measurements in inches EFRCIENCY YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY 00')" US IMPORT DUTY FREE FRF Nominal Operating Cell Temperature(NOcT) 45.7'C (±2'C) Temperature Coefficient ofP_ -0.40%l °C Temperature Coefficient ofVpr -0.27%/°C Temperature Coefficient ofl,c 0.024%/°C Nominal Power- P. (Wp) 260 Cel[Type: 60 REC REmulti-crystalline WattClass Sorting- (Wp) -/-5 3 strings of 20 cells with bypass diodes Nominal PowerVottage-V.(V) 30.7 Glass: 0.125 insolarglasswith anti -reflection surface treatment Nominal Power Current -1.(A) 8.50 Backsheet Double layer highly resistant polyester Open Circuit Voltage -V, (V) .37.8 Frame: Anodized aluminum (black) Short Circuit Current -Ix (A) 9.01 Zep Groove compatible Panel Efficiency(%) 15.8 Junction Box: IP67rated — -- 0.156in(12AWG) solar cable, 2x4724in The electrical characteristics are wit hin•/-10%oftheindicatedal ues ofl _V_an P at standard Test conditions Values at standard test conditions STC(airmass AM l.5, irradiance 1000 W�m', cell temperature 77-F(25°C)). (STC). Connectors: H4 Amphenol At low irradiance of 200 W/nP (AM 15 & cell temperature 77°F (25'C)) at least 97% of the STC panel efficiency will be achieved. Origin: Made in Singapore b. Nominal Power- P., (Wp) .r• 97 Operational Temperature: -40...+185°F(-40...+85°C) Nominal Power Voltage-V.p(V) 29.' Maximum System Voltage: 1000VUL Nominal PowerCurrent-I,,p(A) 6.81 Design Load: 501bs/ft'(2400Pa) longside Open Circuit Voltage -V, (V) 35.7 30lbs/ft' (1436 Pa) short side ShortCircuitCurrent-Isc(A) 7.24 0 Max Series Fuse Rating: 15A Nominal operating cell temperature NOCT(800W/m',AM 15, windspeedl m/s, ambient temperature 68'F(20'C). Max Reverse Current: 15A CERTIFICATION 10 year product warranty. Dimensions 155.55 x39.02 x 1.57 in (1665 x 991 x 40 mm) c RL us 25 year linear power output warranty Area: 17.75ft2(1.65m2) LISTED (max. degression in performance of 0.7% p.a.). UL 1703, Fire rating:Type e1. Class Weight: 43 lbs (19.5 kg) Note' All given specifications are subject to change without notice at anytime. REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing s ^ products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better R _ EC meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Our 1,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com V113M sJalJanuuelos/woo`seouawe-ellap`MMM V(sRepiloH wor; pede) 1Sd wdg of weL ww; Aepu j of Repuoyi 6608-69£-9Z9-L+ :('Ilul) uoddnS Z£8V-ZVV-LL8-L+ :au!IIOH poddnS LZ08-69£-9Z9-L+ Jo LS8S OVV LL8 L+ :au'110H sales woo- djoo-ellap@o poddnS-JalJanul :l!ew3 1loddnS WOO -(JJoo-ellap(Po saleS'Jauanul :I!ew3 sales 8£9V6 VO 'luowaJ-1 'PAIR 3uow9J3 LOL917 •aul `uo!lejodio:) sionpoJd e118a ZV069 al IW1 4OZ 03N Z4'069 010PV t7LOZ 03N 4-LM Z'ZZ VSO'44L41n 4-LOL Z'ZZ VSO `LI L4 In X17VW3N X17VW3N •ouelldwo0 piepuelS SJBDA OL seal 01 lana) eaS anoge w00oZ lanal eas anoge woo0Z %004-0 %OOL-0 (0.58 - Ot>-) 4.484 - olr (Oo58 - ot'-) 30581 - ot- (O.,OL - ot7-) 30841 - OV- (O.OL - ot>) 3.89L - ot7- SNo010 Imuu0i Mcuos JoyoauuOO Ad 17H iouagdwV jo J010auu00 Ad t> OW JoloauuoO Ad t•H IouagdwV uo loloauuoO Ad SOW Jol0auuoO Rd t7Hl louagdwV jo joloouuoO Ad Y-OW (6�0'£) sgl9'9 (6)l£' 4) sg198'Z (44 X 99Z X 94£) 94Z X 170'04 X tt,u (ES X 044 X OOZ ) 60Z X L6'4 X L8'L MOO lMua0 JMV 174-4Z V/N A009 V/N aJ!M leu6!S n5 leu6!s Old (salo(4 owq)„V/£ V/N aziS linpuoo• • 0MV 9-Z4 JMV 04 Gz1S WIM LuIwJai indino VOZ VOZ jjnoj!o jad juaiino Indino •- '. Z L • s6upea lndlno V94 V/N VOL VoZ 17 L 00 A009 0O n009 s6upea lndul suolleagpodS leo!uyaa.L • WNSIS AS SUULM lie 101 ov 012t°J m3HV3119 2!npuooeuO .neon ••--•••• 0V oy _ .AdW Nron+nusMom � •r. ; j✓ . Yom. y s o atldNo, Ad d0.0L NIH11M=1OOM NO.r. 1 s ""7_ ', X013 NMOOlnHS OIdV2d V1130 VAM4 :wej6e1a uo!;aauuoo Z-4 009-ssm lapow woo-seo!lawe-ellap MMM SI1 , o (Aluo L -L 009-SS2j IapoW) uo!leo!unwwoo old ZL 069 alo!lae KM 03N Ul!M lue!Idwoo . sJoioauuo0 Ad Ul!M loauuOO Ise3 . uo!lellelsul 1unoW NoeH . ly6!aMly6!l pue loedwoo . uo!loalad XV VW3N S3mn.L /3=i A3)1 `sJauanu1 le!luapisai aset4d-albu!s s,ellaa qpm opledwoo s! 11 -ZL-069 appe VLOZ 03N to sluawai!nbai uMopin4S p!deH aUl Ul!M lualdwoo AlInl 'walsAs deue Ad le!ouawwoo hews jo leguap!saj Oan009 to loauuoos!p o!lewolne ue ap!nad sao!naa unnopinyS p!deH s,ellaa saa:PanuI 11 9'L�0'£ p4la4 aoj aDinaa unnop4nys pde� 0 F SOLKO y I i .7 Solar Inverters Transformerless (TQ: 3.0 kW, 3.8 kW, 5.2 kW, 6.6 kW, 7.6 kW Wide Operating Voltage Range: 85 - 550V Wide Operating Temperature Range: -13 - 158°F (-25 - 70°C) High CEC Efficiency: 97.5% Integrated AFCI (Arc Fault Circuit Interruption) NEMA 4X plus Salt Mist Corrosion Protection Natural Convection Cooling Dual MPPT (5.2kW / 6.6kW / 7.6kW) Compact and Lightweight UL 1741 / IEEE 1547 / IEEE 1547.1 / CEC co Listed /UL 1699B(Type 1) 1 NEC 690.11 C us INPUT (OC) GENERAL SPECIFICATION MECHANICAL DESIGN STANDARDS / DIRECTIVES Delta Solar Inverters Datasheet for SolarCity 600 v 380 V 85 - 550 V 200 - 500 V 18.0 A 20.0 A 20.0 A per MPP tracker 25.0 A per MPP tracker - 4200 W 5000 W 5600 W 1.5 Internal 2 2 4 3000 W 3800 W 5200 W 6600 W 7600 W 3000 W @ 208 V / 3300 W @ 208 V / 5200 W @ 208 V / 6600 W @ 208 V / 6600 W @ 208 V / 3000 W @ 240 V 3800 W @ 240 V 5200 W @ 240 V 6600 W @ 240 V 7600 W @ 240 V 183-228V@208V/211-264V@240V 14.4A@208 V/ 15.8A@208 V/ 24.0 A@208 V/ 31.7A@208V1 31.7 A@208 V/ 12.5A@240V 15.8A@240V 21.6 A@240V 27.5 A@240V 31.7A@240V 60 Hz 59.3 - 60.5 Hz 57.0 - 63.0 Hz <1.5W <3% 0.99 0.851- 0.85c <50 db(A) @ tin 98 97.5%@208V/975%@240V - -13 - 158`F (-25-70`C) I derating above 122`F (50"C) -00 -185-F (-40 - 85"C) 0 - 100% 2000m above sea level 19.5 x 15.8 x 8.5 in (495 x 401 x 216 mm) 26.8 x 15.8 x 8.5 in (680 x 401 x 216 mm) 43.0 ]be (19.5 kg) 65.0 lbs (29.5 kg) Natural Convection Spring terminals in connection box AWG 12 - AWG 6 Copper (According to NEC 310.15 ) 2 pairs of spring terminals in connection box 4 pairs of spring terminals in connection box AWG 12 - AWG 6 Copper (According to NEC 690.8 ) ZgB- 3 LEDs, 4 -Line LCD Diecast Aluminum NEMA 4X, fEC 60068-2-11 Salt mist UL 1741 Second Edition, CSA C222 No.107.1-01 UL 1998 NEC 690.35, UL 1741 CRD IEEE 1547, IEEE 1547.1 FCC part 15 Class B UL 15998 (Type 1), NEC 690.11 UL 1741 CRD PVRSS, NEC 690.12 (vAth SMART RES) ANSI C12.1 (meet 2%Accuracy) California Rule 21, HECO Compliant, IEEE 1547 WARRANTY 10 years Delta Products corporation, Inc. 46101 Fremont BNd, Fremont. CA 94538 Sales Email: inverter. sales@deltavm•.com Supporl Email inverter, support@d eltai-Com Sales Hotline: +1-877440-5851 or +1-626-369-8021 Support Hotline'. +1-6774 ���� Support (Intl. ). +1.626-369-8019-8019 Monday to Friday from 7 am to 5 pm PST (apart from Holidays) AN Wy ZZ:" 9 L OZ '6Z Judy : pelJodxe lsel aced 4 A8b L Oo-6E9 L-oo8 # luawnoo(i wm sledsz -sddy pue slueled 'aogou lnoLgm 96ump of pergns aje suogeogoadS 'asn goea jo; spnpad sueloSdaZ;o Apligelins agl 6uilguan Jo; alglsuodsai dlalos sl jawolsno ayy'lqueuem pnpoid agl ui of pace;ai suopogpods alos ayl salnlpsum spnpoid s,jeloS daZ yl!m paddiys uo.gmuawrr.)op jasn-pua ayy'pnpad goes jo; dlueLam pnpomd uellum egl w pewelum si dluewem alos s jejoS deZ'sammes jo slonpoid sli lnoge jo jejoS deZ dq dluewem ssejdxa due eleajo you seop;uewnoop slgy 9991 In of palsn 6091-098 'ON lJed dllo ojiM Oa £OLZ In PUe L9ti In of palsn 1151�58 *ON Wd Zn daZ punoaE) L9ti 1-058 Jo 8851-059 Od) 09b 1-058 JO 9951-058 (I) 'ON IRd dei Pu3 rof £OLZ In of palsn 241-058 JO 909l,-098'ON PBd dpE) £OLZ In 01 palsil 16E 1-058 'ON ued ;ood 6u110na1 V0o-1£91-098 £00-1E9L-098 200-1£91-098 M -M 1,-098 'ON Ued 6e-1 JayseM palnldeo EoLZ In of Pals!l 8291-098 'oN ued }lasul 6ulyseld £oa In of palsn MLZ In of palsn £oLZ In of pals!I 61,9L-099 Jo 88E 1-058 'ON Ped £ 110-009 Jo 8091-099 'ON Ped E£91-098 'ON Ped )loolualul :W!ms Aeiid 3oolg 6ui3unoW woo"Jelosdoz s;ueuodwoo Wy ZZ:LL 9LOZ'6Z Judy :peljodxe lsel alep a naa L00 -669L-008 # luawnood woo'sledsz sddy pue sluoled "aogou lnoglim a6uego of loe(gns are suogeo4vadS asn goes jo; spnpoJd sjeloSdoZ;o dliligenins agl 6ud4uan jo; apsuodsai dlalos si Jewolsno egy'dlup-uu m pnpad agl w of paws;aj suogeoUpods alos agl sopl.4sum spnpoid sueloS daZ 41!m paddigs uoReluewrruop �asn-pua agy 'pnpad yoea jo; dluewem lonpmd uspum egl ui peweluoo si dluenem alos s,jeloS daZ 'seowes jo spnpoid sll Inge jo jeloS deZ dq /queLem ssejdxe due eleejo lou seop luewnoop slay s;oa al6uiys uogisodwoo Jo} S dwoo SZ A6olougoal 6uijunoW Ad IanaTIxaN aejoSd Z Aj!DJejoS; ABolougoal builunon Ad 8na-1-1xaN aejoSd Z Aj!:)jejos,+e_ woo'Jelosdaz saoinap 6uiuopsod aJim Jol ggg 1 -in of pelsq slonpoJd luawa6euew aJim daZ .qZ o; do SJan914ueo pue •ZL o; do sueds Jo; p8J8au16u3 £OLZ In of palsli In aJe slonpad 6uipuoq dwoo Sz L9b In PUe £OLZ In of palsli in aJe slonpad 6uipunoJ6 dwoo SZ SpJepuels OL -L Pue 90-L 30S`d of 1Jod9J leuunl pwM £OLZ In Jad;sd og of saJnssaJd peol mous pue l;!ldn puim appow slJoddns dwoo Sz suoileluauo adeaspuel pue lieJlJod w slielsul slooJ pegolid Jol pou6isaa suol;eo�laadg �31S11 In .Z ad (lq Jo ,1 adRl, se pagpeo JaJnloelnuew (ue wool sappow 6uisn pallelsw uaym 6wlea aju ,y. sselo £OLI. In a sey dwoo SZ puoq leoiA3919 pue leinloruls seleen ejempJey pami-in 6wpuoq olny �vawoo selnpopy alggedwoo daZ Ile ylim s)NoM 0 vLo slooJ al6uigs uogisodwoo Jo; uoilnjos 6uqunow Ad =70 uol duose Q g�1rdWo7D s;oa al6uiys uogisodwoo Jo} S dwoo SZ A6olougoal 6uijunoW Ad IanaTIxaN aejoSd Z Aj!DJejoS; ABolougoal builunon Ad 8na-1-1xaN aejoSd Z Aj!:)jejos,+e_ 08/27/2009'THU 17:42 FAX 303 237 8929 303-Best way » »» 1- derful roofing I) ti 1 All, t 1TF01 ltispec ©rs v�rFl,n b� tt�d t�nssshs c_ ` ©n "f ._.. — -- - Ca1t b� 3 a�3 P�i1�o receive fns{��c #ton �kfi� f�tlawt�� ktus�t FOlJTIDR7tON' {NSP €C71ONS, - Oni6 -; - `�: COkI't2�'s' _ ' - 2002/002 j - FootngsfCaissaiis En Stemw�N {Ct,Gj_Concrete . tased 44u ... - ReigEorcmg ` WeafFierproof/ Prench Dram - '_ - RougF,luenkJn9 •-" : - ol r�� ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: key/ Job Address: /as35 w 3 ?� 4rii Permit Number: FJF /7,�7 ❑ No one available for inspection: Time ar AMAg Re- Inspection required: Yes, When corrections have been made, call for re- inspection at 303- 234 -5933 Date: /,14/ e97 Inspecto DO NOT REMOVE THIS NOTICE f° / 41 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: t3>c:~ 9 ,xreAnaE Job Address: r©S3S?~a ~i Permit Number: /&et0 Y7 ❑ No one available for inspection`: Time ys AM/4 Re-Inspection required: Yes dg2 ` *When corrections have been made, call for re-inspection at 303-234-5933 Date: ~✓f0/e Inspector: DO NOT REMOVE THIS NOTICE INSPECTION RECORD o ccupancy /Type 'V INSPECTION LINE: (303) 234 -5933 r a, F fi ti Inspections will not be made unless this card is posted on the building site �y Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons - — — Stemwall / (CEG) Concrete Encased Ground Electrical Service Reinforcing or Monolithic I Rough Electric Weatherproof / French Drain - Rough Plumbing Sewer Service Lines Gas Piping Water Service Lines Rough Mechanical IN FOR PLANNING & ZONING, .FIRE AND PUBLICE WORKS SHOULD BE ALL LEAST ONE. WEEKPRIOR TO FINAL INSPECTIONS. CONCRETE SLAB FLOOR - Electrical (Underground) - Plumbing (Underground) Heating (Underground) ROUGHS Sheathing Insulation :Lath / Wall tie - — — Mid -Roof Electrical Service Roof I Rough Electric Building Final - Rough Plumbing Fire Department Gas Piping R.O.W & Drainage - Rough Mechanical IN FOR PLANNING & ZONING, .FIRE AND PUBLICE WORKS SHOULD BE ALL LEAST ONE. WEEKPRIOR TO FINAL INSPECTIONS. Parking & Landscaping Framing 2 i ie Insulation Plumbing Drywall Screw Mechanical FINALS Electrical Plumbing Mechanical Roof Building Final A I . /'C Fire Department R.O.W & Drainage - IN FOR PLANNING & ZONING, .FIRE AND PUBLICE WORKS SHOULD BE ALL LEAST ONE. WEEKPRIOR TO FINAL INSPECTIONS. Parking & Landscaping - 'NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED P Df1TC! TLJ IC r-A Dn =Dri AA - ruc IA10 ATLJCD City of Wheat Ridge P N, )7 '.'100047 -10535 W 32ND AVE '.Replace steps, railing, and failed f 'ACTS /588-6683 Lee Coren Leaf 01/07/2010 IS: 0.7/06/2010 110 if ` 1518 DECKTEC OUTDOOR DESIGN, INC 1ARY ESTIMATED PR 3EC UU7~~-ION: 4,200.00 FEES e~ p~rz " " "y ` 144.70 / ~ / ~v u~YJV~~~l l sE m Fee cation -94.06... .00 75.6 * . 314.36 ¢flia u' he stairs. 10". not allow, passage of a 4" Lt application' are accurate, and do not violate applicable SG OFFICE.: (303)235-2855 INSPECTION THE FOLLOWING BUSINESS DAY.:' City of Wheat Ridge Building Division m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Building Permit Application Property Address: Aye- Date: Gil 4 Plan 1 b- Cow Permit l mc yL , j- Property Owner (pleaseprint):4a_ Phone:303 ~~~-~Zn3 Mailing Address: (if different than property address) Address: Contractor License ~ Phone- 15~ D Sub Contractors: Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Approval Exp. Date: Approval: Approval: Use of space (description)..cD2cK Construction Value: s q 2-On 07 Description of work: (as calculated per the Building Valuation Data sheet) C,CR~ "'~fi e-P Plan Review (due at time of submittal): I $770(0 . 11 ~~t^'L~' 'S a~~C~ ~f~2VtAiV1 Sq. Ft./L.Ftadded: #0 Squares BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all. measurements shown, and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE OWR) (CONTRACTOR) or ERSONAL REPR S _NTATIVE of OW R (CONTRATOR) PRINT NAME; Y \n! ~ I OV~r SIGNATURE. ~Q- Date: Bldg Valuation: Contractor: ~RL_ nC, Property appraisal system F POrP Property a attgs`§$ Int Bt10n ~ li Previous 3 OF 18 Next Page 1 of 2 GENERAL INFORMATION Schedule: 201139 Parcel ID: 39-281-18-019 Print Helo_ Status: Active Property Type: Residential Property Address: 10535 W 32ND AVE Owner Name(s) WHEAT RIDGE CO 80033 5504 LEAF CAREN MICHELE Mailing Address: SAME ADDRESS AS PROPERTY WALDMAN LEE Neighborhood: 2403 - APPLEWOOD VILLAGES, PROSPECT VALLEY AREAS PROPERTY DESCRIPTION Subdivision Name: 648600 - ROLLING HILLS BI _KS F;-R Block Lot Key Section Township Range QuarterSection Land Sqft 008 - OSB 28 3 69 NE 1060 008 0016 00A 28 3 69 NE 13285 Total 14345 Assessor Parcel Maps Associated with Schedule man39-281. odf PROPERTYINVENTORY Graphic Parcel Map MapQUest Location Property Type RESID Design: Raised Ranch Item Quality FULL BATH Average 3FIX-3/4 BATH Average MAIN FIREPLCE Average BSMT FIREPLCE MAIN BEDROOM EVAP COOLER BSMT BEDROOM Adjustment Code Adjustm HOT WTR HEAT 1801 BSMT HOT WTR 1367 SALE HISTORY Adjusted Year Built: 1963 Areas Quality Construction Sqft FIRST FLOOR Average C 1801 BSMTTOTAL Average 1367 COVERED PORCH Average 148 WOOD DECK Average 538 BSMT GARAGE Average 495 BSMT FINISHED Average 1367 Land Characteristics Traffic Collector Street Sale Date Sale Amount Deed Type Reception 08-19-1995 0 Quit Claim Deed - Joint Tenancy FQ_19-7747 05-30-1996 179,000 Warranty Deed - Joint Tenancy F0247294, 02-05-2000 0 Quit Claim Deed F1016405 07-14-2003 310,000 Warranty Deed F1808876 04-16-2007 0 Quit Claim Deed - Joint Tenancy 2007048929 TAX INFORMATION 2009 Payable 2010 Actual Value Total 310,890 Assessed Value Total 24,740 Year Built: 1961 Improvement Number: 1 . View Mill Levy Detail For Year 20 2009 Mill Levy Information Tax District 3141 County 24.3460 School 48.1450 10 2009' http://www.co.jefferson.co.us/ats/displaygeneral.do?sch=201139&offset=2 1/7/2010 Property appraisal system Treasurer Information WHEAT RIDGE 1.8300 REGIONAL TRANSPORTATION DIST. 0.0000 URBAN DRAINAGE&FLOOD CONT DIST 0.5080 URBAN DRAINAGE&FLOOD C SO.PLAT 0.0610 WHEATRIDGE FIRE DIST. 4.2570 WESTRIDGE SAN. DIST. 8.0500 Total 87.1970 Page 2 of 2 http://www.co.jefferson.co.us/ats/displaygeneral.do?sch=201139&offset=2 1/7/2010 I 4#4 0 4 ~a j ui 41. i 4 yii U ~ 1 ~ U LIA 0 v sq~ wn F.. _I 6 al L2 Q~ v V i S ..a s P f~ i ~\J x N p~ 1 I~ f 1A , N i (Fill, V" t r u E f } N a\ r t t@ d 1 $ j as ffffff7f < m c I I 3r { } f C* yY 6J; Y ~ ~ X21 IAA r O T r I P ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: i r rt, Job Address: Permit Number: Oq 172 7 Plltlfnn, ti :f- ❑ No one available for inspection: Time x•36 AMIPM Re-Inspection required: Yes '/No When corrections h have been made, call for re-inspection at 303-234-5833 Date: f0. 1 3- Inspector: DO NOT REMOVE THIS NOTICE ' City of Wheat Ridge Faxed Roof Permit PERMIT - 091727 PERMIT NO: 091727 ISSUED: 08/27/2009 - - ;JOB ADDRESS: 10535 W 32ND AVE EXPIRES: 02/23/2010 DESCRIPTION: Reroof 29 sqs. CONTACTS owner `720/313-5312 Caren Leaf sub 303/984-.7663 RONALD E. ANTENER 07-01711-DERFUL ROOF & RESTORATION * * PARCEL INFO * ZONE CODE: °UA USE: UA % SUBDIVISION: 0647 :BLOCK/LOT#: 0/ FEE. SUMMARY 'ESTIMATED PROJECT VALUATION: -5,133.00 FEES Permit Fee 162.90 ~4 e Total Valuation .0p CL's" Use Tax 92.39 r Y£ a"a TOTAL 255.29 j ..Conditions 'Both front and back of permit need to be posted on job site. If one or the other ::..is. not present, INSPECTION WILL NOT BE PERFORMED. 6 nail installation mid-roof inspection required.. Board sheathing spaced more than a 1/2 of an inch apart. requires plywood overlay on entire roof. ice and rwater shield required from,eave edge to 2' inside exterior walls. Subject to. field inspections. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all. i;. measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and th t ~)Iassume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other app icable Wheat idge Ordina cea, for work under this permit. Plans subject to field inspection. ciI signature of contractor/owner date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge,. Colorado or any other applicable ordinances of the city. - 2This permit shall expire 180 days. from the issue date. Requests for an extension must. be received prior to .expiration.. S date. An extension may be granted at the discretion of the Building Official. 3. If this. permit expires, anew permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not - f.. exceeded.. one (1):year. . If. changes have been. or if suspension. or. abandonment exceeds one (1),.year, full fees shall be :paid for a new. permit. - 4. No work of any manner shall be done that will change. the natural flow of water causing a drainage problem. 4 S.. :Contractor: shall notify the Building Inspector twenty-four (24). hours in advance for all inspections and shall receive written approval on inspection card before. proceeding with successive phases of the job. 6. The issuance of a permit or. the approval of drawings and specifications shall. not be construed. to be a permit for, nor an approval of, violation of the provisions of the. building codes or any other ordinance, law, rule or regulations r<; All plan e w subject to field inspections. 0 F Signature Ch' Building. Official date "INSPEC ON REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 'r REQUESTS. MUST BE .MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. r: Aug 27 09 12:04p IDERFULROOFING 3039844860 p.1 ef~~ City of¢¢ , Ldge Date. (J~ . i~ COMMUN.tTY DEVELOPM"ENT~~Permit Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-2345933 Facsimile Building Permit Application Property Address: J OS 3:s- W V ,0z n4 H 1/ Property Owner (please print): Ca 1-ev-i Lem F * 1-'e ii, am Phone: Tao -3 (3 - 53 /a Mailing Address: (ifdifferentthan property address) Address: City, State, Zip: Contractor: ~CK u` iL~Qt~1hIG 1~r~Tt~/Z`~dl~ (.nntractorLicense t-)'7 i- 1 Phone:- Sub Contractors: Company Name: License 9: Expiration Date: TradelProfession_ Approval: Use of space (description : • e , Descrt tton of work Q C, i Construction y=n o O. C 30 y i Co P Plan Review [due attime ofsUbmiuaq: S Sq_ F:.IL.Ft added: Souares oA-L BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT ordinances, I hereby certify that the setback dislances proposed by this permit application are accurate, and do not violate applicable rules or. egulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown. and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field Inspection. CIRLCE GIVE.': PRINT NAME ZONING COMMENTS: Zoning: Reviewer. PUBLIC WORKS COMMENTS: Reviewer: PERSONAL SIGNATURE: DEPARTMENT USE ONLY BUUAING DEPARTMENT COMMENTS: Reviewer. FFRE DEPARTMENT:: ❑ approved wl comments ❑ disapproved ❑ no review required (GONTRATOR) Bldg Valuation: OCCUPANCY: Credit Card Payment: Use creditcard listed on file. Date: 1 V` name: ~1 F I le {tea t~ Signature: DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 13973 BUILDING INSPECTION LINE - 303-234-5933 Date 6/5/02 CITY OF WHEAT RIDGE : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner: HALL Property Address : 10535 W 32ND AVE Phone : 733-5770 Contractor License No. : 18699 Company : R T P Roofing Co. Phone : 303791-2223 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $3,286.00 I hereby certiy that the setback distances proposed by this permit applica6on are accurate, and Pefmit F0C' : $97.25 do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations Plan RevieW F2e : $0.00 made are accurate; that I have read and agree to abide by all conditions printed on this USe T8X : $39.43 application, and that I assume full responsibilityfp r compliance w'tlf7he Wheat Ridge Buydin Code (U.B.C.) and all other applicable W (dge ordi ~ e, f~rwork under this per it. Total: $136.68 (OWNER)(CONTRACTOR) SIGNE DATE US2 : Description : T/O 3 LAYERS INSTALL 30 YR. DIMENSIONAL OVER 30# FELT 1~~y l ~ Electrical License No : Plumbing License No : Mechanical License No : Company : Expiration Date : Approval: Company: Expiration Date : Approval: Company: Expiration Date : Approval: (1) This permit was issuetl in accordance wi[h the provisions set forth in yopur application and is subjectto the laws of the State of Coloredo and to the Zoning Regulations and Building Code of Wheat Ridge, Coloredo or any oiher applicable ordinances of the City. (2) This permi[ shall expire if (A) the work authorizetl is not commenced within sizty (60) days from issue date or (B) ihe builtling authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may 6e acquired kr a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans antl specifica[ions and any suspension or abandonment fias not exceeded one (7) yeac If changes are made or if suspension or abandonment ezceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural Flow of water rausing a dreinage problem. (5) Contractor shall notify the Building InspeQOrhventy-four (24) hours in advance for all inspections and shall receive written appmval on inspection card before proceediing with successive phases of thejob. (6) The issuance of a permit or the approval of drewings antl specifcations shall not be construetl to be a permit for, nor an approval of, any violation oF the provisi s f the buildi ~codes or any other ordinance, law, rule or regula6ort / C ' ouilding I ector `)EPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner : Property Address : Contrector License No. : J~~aq l Company : kTp /I Phane : "733' S'7~/U Phone: OWNER/CONTRAC70R SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certiFj that the setback distances proposed by this permit application are acwrate, znd do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance ifh the Wheat Ridge Building Code (U.B.C.) and all other applicable Whe Ri ge ordin nce , f~f work under this pe it. ~ (OWNER)(CONTRACTOR) SIGNED ~7~~! DATE L 5O~ 67CP-64 Building Permit Number : Description : T/D Date : Construction Value Permit Fee : Use Tax: Total : Use BUILDING DEPARTMENT USE ONLY Zofii'n,g;-om en~ Approval : Zoning : Bui~dIg;Commen .~s.~ Approval : <Publ c o1m eH~_ Approval: Occupancy : Walis SIC : Sq. Ft. : Roof : Stories : Residential Units : Electrical License No : Company ; Plumbing License No : Company : Mechanical License No : Company : Expiration Date : Expiration Date : Expiration Date : Approval : Approval : Approval (1) This permit was issued in accortlance with the provisions set forth in yopur application and is subjecl So the laws o( the State of Coloratlo antl to the,ZOning Regulations antl Builtling Cotle ot VJheat Ridge, Coloratlo or any other applicable or0inances ot the City. (2) This pertnit shall expire if (A) the work authonzetl is not commenceG within sixty (60) tlays from issue date ar (B) the builtling authorized is suspentled or abantloned tor a period of 120 days. (3) If this permit expires, a new permit may be acquiretl (or a fee ot one-half the amount nortnally requireG, provitletl no changes have been orwill be made in the ori9inal plans antl specifiwtlons and any suspension or abandonment has not exceeded one (1) year. If changes are ma0e or if suspension or abantlonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natu2l flow of water causing a tlrainage pro6lem. (5) ConVaqor shall notify the Building Inspector twenty-four (24) hours in advance tor all inspections and shall receive written approval on inspeciion carC before proceediing with successive phases ot Ne7'ob. (6) The issuance ot a pertnit or the approval of d2wings and specifcations shall not be wnstrued to be a permit for, nor an approval o(, any violation ot the provisions of the Euiltling cotles or any oNer ortlinance, law, rule or regulation. Building Inspector