Loading...
HomeMy WebLinkAbout7380 W. 32nd AvenuePERMIT:70M� / 53 ADDRESS: 7�k L 32A Ai,,P, JOB CODE: INSPECTION RECORD QqF iii z_ Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection . Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground �/�! 5s , Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof �/�! 5s , 307 Metal / Lath / Stucco J 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 'i15 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial j% icy 318 Boiler / Furnace 319 Hot water tank 1p") 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential j% icy 404 Final Electrical Commercial 405 Final Mechanical Residential 1p") 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning Inspections from these entities shall be requested one week in advance. For landscaping and parking inspections please call 303-235-2846 For ROW and drainage inspections please call 303-235-2861 For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works 413 Flood plain Inspection 414 Fire Insp. / Fire Protection 415 Public Works Final 416 Storm Water Mgmt. 417 Zoning Final Inspection 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. The City of Wheat Ridge Third Party Form Check List Property Address 7380 W 32^d Ave Permit Number 201707953 Permit Issued Date 10/03/2017 Owner Information Property Owner Information Bob Orr Property Owner Address 3785 High Ct. Wheat Ridge, CO 80033 Inspector Information Inspection Company Certified Building Consultants Inspector Name Kraig Stanforth;Travis Stanforth Inspector Contact info. 720-940-1180 TStanforthCBC a[)gmail.com Inspector Statement of Acknowledgement *1 hereby acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Building Department. *1 hereby acknowledge the roofing system for the referenced building has been inspected and found to the in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as the City of Wheat Ridge Policies and Procedures and manufacturer's recomli-I noations and specifications. Inspector: �` Date: (✓ �'% 117 Property Owner Statement of Acknowledgement *1 hereby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspec7,5, in lieu of the City of Wheat Ridge Buildin Division inspection. Property Owner/Agent: ��„.i Date: This original document and permit card, as well as the roofing checklist, must be submitted to the Chief Building Official within seven days of the final inspection. Drop off in person Permit Counter 2nd Floor 7500 W. 291h Ave Wheat Ridge, CO 80033 CBC Wheat Ridge Roof Inspection Packet Submit via Email Kcooka.ci.wheatridge.co.us Page 2 of 6 The City of Wheat Ridge Inspection Check List Notes Final Roof Roof Inspection ❑ N/A X Pass ❑ Fail Structural roof components ❑ N/A X Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A Pass ❑ Fail Flashing for roof and walls ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A � Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) ❑ N/A 4 ' Pass ❑ Fail Verify sheathing nail pattern (See Policy and Procedures) /JCN/A ❑ Pass ❑ Fail Crickets and saddles where needed ❑ N/A )s:t Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A J' Pass ❑ Fail Verify vent caps ❑ N/A Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle ❑ N/A Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A j Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A /�" Pass ❑ Fail Underlayments must follow 2012 IRC/2012 IBC ❑ N/A p Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A jW Pass ❑ Fail Dripedge shall have min. 2" of overlap ❑ N/A I;C Pass ❑ Fail Dripedge should extend down min. 2" past roof deck ❑ N/A Pass ❑ Fail Dripedge shall be mechanically fastened 12" OC ❑ N/A Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min. slope 1/4:12 slope must be installed in accordance with the manufacturer's letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less than 3:12 N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min. of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with the sections overlapping a min. of 4" Tile Roof Requirements N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope N/A ❑ Pass ❑ Fail Slopes 4:12 and under require double underlayment CBC Wheat Ridge Roof Inspection Packet Page 5 of 6 Company Name: Inspector Signature: Date of Inspection: The City of Wheat Ridge Inspection Check List Notes Final Roof Notes CBC Wheat Ridge Roof Inspection Packet Page 6 of 6 The City of Wheat Ridge Inspection Check List Notes Mid -Roof Roof Inspection ❑ N/A ` i Pass ❑ Fail Structural roof components ❑ N/A �°�" Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A '&KPass ❑ Fail Flashing for roof and walls ❑ N/A Pass ❑ Fail If new sheathing is installed, verify that it is listed in the permit description (Valuation must be adjusted) ❑ N/A Pass ❑ Fail Verify sheathing nail pattern (see Policy and Procedures) y N/A ❑ Pass ❑ Fail Crickets and saddles where needed ❑ N/A Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A Pass ❑ Fail Verify vent caps ❑ N/A Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle ❑ N/A Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A Pass ❑ Fail Underlayments must follow 2012 IRC/2012 IBC ❑ N/A Pass ❑ Fail Verify roof slope for proper damage ❑ N/A Pass ❑ Fail Dripedge shall have min. of 2" overlap ❑ N/A Pass ❑ Fail Dripedge should extend down min. 2" past roof deck ❑ N/A Pass ❑ Fail Dripedge shall be mechanically fastened 12" OC ❑ N/A Pass ❑ Fail 90 LB roof roofing shall not be applied to roof slopes less than 2:12 slope. Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 N/A ❑ Pass ❑ Fail Above roof insulation R-25 N/A ❑ Pass ❑ Fail Below roof residential R -38 j N/A ❑ Pass ❑ Fail Below roof commercial R -32 i N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min. slope 1/4:12 slope must be installed in accordance with the manufacturer's specifications. Must have manufacturer's letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less than 3:12 Id N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min. of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with the sections overlapping a min. of 4" Tile Roof Requirements _. N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope N/A ❑ Pass ❑ Fail Slopes 4:12 and under require double underlayment CBC Wheat Ridge Roof Inspection Packet Page 3 of 6 Company Name: Inspector Signature: Date of Inspection: The City of Wheat Ridge Inspection Check List Notes Mid -Roof Notes ilding Consultants 0/,�? 7 // CBC Wheat Ridge Roof Inspection Packet Page 4 of 6 ► ' , City of Wheat Ridge Residential Roofing PERMIT - 201707953 PERMIT NO: 201707953 ISSUED: 10/03/2017 JOB ADDRESS: 7380 W 32nd AVE EXPIRES: 10/03/2018 JOB DESCRIPTION: Residential Re -roof to install GAF asphalt shingles - TOTAL 41.5 sq (32 sq pitched / 9.5 sq flat) *** Unit #l(North): 18 sq Pitch = 4/12 Valu: $5670.00 *** Unit #2(West): WITH REDECKING - 10 sq(8 sq pitched / 2 sq flat) Pitch = 7/12 Valu: $3351.25 *** Unit #3(East): 13.5 sq(6 sq pitched / 7.5 sq flat) Pitch = 8/12 Valu: $4252.50 *** (3rd party inspector required) *** CONTACTS *** OWNER (303)231-9949 ORR ROBERT ALLEN SUB (303)332-6224 Chuck Gardner 021423 GARDNER CONTRACTING, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 13,273.75 FEES Total Valuation 0.00 Use Tax 278.75 Permit Fee 267.70 ** TOTAL ** 546.45 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications= applicable building codes, and all ap�allyauthoncable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property anam authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am lzed toinclude alperformed and that allwork tobe perrmed is disclosed in this document and/or its' accompanying approved plans and specifications. 17 Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalppermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chiei 3uilding Official oW Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett From: no-reply@ci.wheatridge.co.us Sent: Friday, September 29, 2017 12:01 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Follow Up Flag: Follow up Flag Status: Completed Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes IT residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) L 7380 W 32nd Ave Unit #1 Bob Orr 303-231-9949 49 Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Signed Proposal.pdf Contract CONTRACTOR INFORMATION Contractor Business Gardner Roofing Name ,l L Contractor's License 0214231 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) 3033326224 909 Telluride St Contractor Email Address info@gardner-contracting.com Retype Contractor Email info@gardner-contracting.com Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope ofwork. Project Value (contract I� s %J value or cost of ALL materials and labor) =� - Are you re -decking the No roof? Is the permit for a flat Pitched roof (2:12 pitch or greater) roof, pitched roof, or 50 both? (check all that apply) What is the specific pitch 4/12 of the PITCHED roof? How many squares are 18 part of the PITCHED roof? Describe the roofing GAF Timberline HD materials for the PITCHED roof: Type of material for the Asphalt PITCHED roof: Provide any additional House detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to 51 submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Nick Martens Email not displaying correctly? View it in your browser. 52 Dane Lovett From: no-reply@ci.wheatridge.co.us Sent: Friday, September 29, 2017 12:05 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Follow Up Flag: Follow up Flag Status: Completed Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) 7380 W 32nd Ave Unit #2 Bob Orr 303-231-9949 53 Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Signed Proposal.pdf Contract CONTRACTOR INFORMATION Contractor Business Gardner Roofing Name Contractor's License 021423 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 3033326224 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 909 Telluride St (Primary address of your business) Contractor Email Address info@gardner-contracting.com Retype Contractor Email info@gardner-contracting.com Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work: Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or 10 / —3150— Yes / Flat roof (less than 2:12 pitch), Pitched roof (2:12 pitch or greater) 54 both? (check all that apply) What is the pitch of the 1/12 FLAT roof? How many squares are 2 part of the FLAT roof? Describe the roofing Mod Bit material for the FLAT roof: Type of material for the Other (specify below) FLAT roof. If "Other" is selected Modified Bitument above, describe here: What is the specific pitch 7/12 of the PITCHED roof? How many squares are g part of the PITCHED roof? Describe the roofing GAF Timberline HD materials for the PITCHED roof: Type of material for the Asphalt PITCHED roof: Provide any additional House detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. 55 I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Nick Martens Email not displaying correctly? View it in your browser. 56 Dane Lovett From: no-reply@ci.wheatri dge.co.us Sent: Friday, September 29, 2017 12:08 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Follow Up Flag: Follow up Flag Status: Completed Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) 7380 W 32nd Ave Unit #3 Bob Orr 303-231-9949 61 Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Signed Proposal.pdf Contract CONTRACTOR INFORMATION Contractor Business Gardner Roofing Name Contractor's License 021423 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 3033326224 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 909 Telluride St (Primary address of your business) Contractor Email Address info@gardner-contracting.com Retype Contractor Email Address DESCRIPTION OF WORK info@gardner-contracting.com TOTAL SQUARES of 13.5 the entire scope of work: Project Value (contract 425 5 value or cost of ALL materials and labor) Are you re -decking the No roof? Is the permit for a flat Flat roof (less than 2:12 pitch), Pitched roof (2:12 pitch or roof, pitched roof, or greater) 62 both? (check all that apply) What is the pitch of the 1/12 FLAT roof? How many squares are 7.5 part of the FLAT roof? Describe the roofing Mod Bit material for the FLAT roof. Type of material for the Other (specify below) FLAT roof: If "Other" is selected Modified Bitument above, describe here: What is the specific pitch 8/12 of the PITCHED roof? How many squares are 6 part of the PITCHED roof? Describe the roofing GAF Timberline HD materials for the PITCHED roof: Type of material for the Asphalt PITCHED roof: Provide any additional 6 Sq House and 7.5 Sq Garage detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. 63 I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Nick Martens Email not displaying correctly? View it in your browser. 64 909 Telluride St, Aurora, CO 80011 303-332-6224 Phone - 866-524-1369 Fax To: Bob Orr September 12, 2017 Work Proposal 73&-�, Job Address: '$&' W 32nd Ave. #1 Wheatridge, CO. 80033 Scope of work including labor and materials: - We will remove and dispose of existing composition roofing in an offsite waste disposal location - Install new drip edge flashing on all rake and eave edges- color- Bone White - Install synthetic felt underlayment - Install ice and water shield around base of all roof vents and penetrations, and at eaves extending 2' inside heated walls - Replace roof vents and flashings. - Install new GAF Timberline HD shingles- Shakewood - Replace all gutters and downspouts- White We hereby propose to furnish labor and materials - complete in accordance with the above specifications, for the sum of $ 9,306.08 + permit fee with payments as follows: $ zero down and balance in hill upon completion. Gardner Roofing, LLC shall hold in trust any payment received from you until Gardner Roofing, LLC has delivered roofing materials at the site or has performed a majority of the roofing work on your property. Gardner Roofing, LLC's workers' compensation and liability coverage insurer is Colorado Insurance Professionals, 303-755-8600. Property Owner is _X_ / is not intending to make payment from the proceeds of a property and insurance All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra costs, will be executed only upon written orders, and will become an extra charge over and above the estimate. All agreements contingent upon accident, or delays beyond our control. This proposal subject to acceptance within thirty days and is void thereafter at the option of the undersigned This price does not include any supplements approved by Insurance Company including but not lindled to Permit Fee Authorized Signature: Acceptance ofli ' itComte: " Comm UNITY DEvELoPmiENKr P1801permit# Building & Inspection Services Division 7500 W. 29'h Ave., Whet Ridge, CO 80033 Plan Review Fee. Office: 303-235-2355 * Fax: 303-237-3929 Inspection Line: 303-234-5933 Building Permit Application a n0 ; **" (if different than property address) xi Address: Cit State, Zip: r „' .. Vit' Complete all information can BOTH sues of this form «®m»*<*«0 # 0 <COMMERCIAL STR■ <:-°-CAL SERVICE UPRADE NEW RESIDENTIAL STRUCT\ COMMERCIALRO /\ ■ COMMERCIAL ADDITION� 0 RESIDENTIAL ROOFIN/ ■ RESDENTiAL ADDITION 0 WINDOW REPLACEMENT @ COMMERCIAL ACCESSORY STRUCTURE (Garage, she deck,etc.) ■ RESIDENTIAL\\ ACCESSORY STRUCTURE CT : (Garage, 2 shed,%deck,%�. $ y CHANICAL /SYSTEM/APPLIANCE2/2REPAI REPLACEMENTor .F %F ». « a \ \\ :. \ \ ^\% \� \Gallons Ampsw ?y«yy«�:2a Other mmomm 16. Building Permit Application (Complete MI h19fVWftd Wenj 00mP/ease print): Z�6e& '5 () P,' (�, Phone: ' A III #V7 T ii li Ty V U =27""M 161 • FIRE DEPARTMENT.: 0 approved W/ COMMentS 0 disapproved 0 no review required City of Wheat Ridg z e Municipal Building 7500 W 9"' Ave. Wheat Ridge, CO 80033-8001 P: 301235,2855 F: 303: �237.8929 6/25/12 Grey Anderson American Restoration, Inc. P.O. Box 12379 Denver,Co. 80212 Re: 7380 West 32" Avenue I am in the process of reviewing plans for 7380 W. 32" Avenue and require tine following information to continue any review. Senior Combination Inspector/Plans Examiner 7500 W. 29 Avenue Wheat Ridge, CO 80033 Office (303) 235-2850 Fax (303) 235-8929 NYvvw.cL-,vheatHdge.co.us I eclat --- � O'clock ., I N Reception No, RECORD OF JEFFERSON STATE OF COLORADO QUIT CLAIM DEED RECEPTION N O. 1341078 11/19/84 10:50 THIS DEM, Made this day of t984 between Judith,Ann-,'Orr Of the *County of Adams and State of COlor gmtorW. and Robert Allen Orr also known by street and number as., 7380 West 32nd Avenue, Wheatridge, Colorado, 80033. TO HAVE AND TO HOLD the same, together with all and singular the app ur t enances an d plivileges thtreumo belonging or in anywise thereunto appertaining, and all the estate, ri fitic, interest and claim Whatsoever,0LIT beh of the grameeX his h an d ass f IN WITNFSS WHEREOF, The granto*) ha s executed this dced on the date set forth abov,_, J1 t HE Or r My commission expires % * If in Denver, insen "City and r , Igoe , Witness my hwW and offici seal. Im I JEFFERSON COUNTY COLORADO REAL PROPERTY VALUATION Jefferson County Assessor 100 Jefferson County Pkwy NOTICE • TE — MAY 1, 2012 Golden, •0 THIS IS NOT ! 1 a 1 • 1 ►• ii 1 R ROBERT ALLEN PO BOX 9 DENVER, CO 80212-0379 SCHEDULE NO. PROPERTY ADDRESS 022265 7380 W 32ND AVE Regular Office 5:3 PM, • s s s s F TI • s ' 1 PM May 16 « 30 6:00 PM AREA NEIGHBORHOOD 02 2408 PROPERTY CLASS TAX DIST RESIDENTIAL 121; 3142 SUB BLOCK LOT KEY SEC TWN RNG CIS 064800 001 0002 OOD 26 03 69 CURRENT YEAR ACTUAL VALUE PRIOR YEAR ACTUAL VALUE (appraisal date June 30, 2010) (appraisal date June 30, 2010) CHANGE IN VALUE 321,370 321,370 O s' ITEMS NO. AREAS CONST. SQFT ADD. CATEGORY SQFT MAIN BATH 1.0 FIRST FLOOR FRAME 894 MAIN BEDROOM 3.0 112 STORY TOT FRAME 408 MAIN FIREPLCE 1.0 112 STORY FIN 408 BSMT TOTAL 408 COVERED PORCH 132 * LAND CHARACTERISTICS TRAFFIC COLLECTOR STREET §� » : ■2,. y w\ \� hone »?< aster D a t e . .. . American Restoaration Inc. Client: Orr, Bob Property: 7380 W, 32nd Ave, #2 Wheat Ridge, CO 80033 Operator Into, Operator: GRAY Estimator: Terry Aumiller Business: P 0 Box 608 Pine, CO Type of Estimate: Fire Date Entered 6/1/2012 Date Est, Completed: 6/22/2012 Date Assi-nevi: 61112012 Date Job Completed: Price List: CODE7X—JLTN' 1 2 Labor Efficiency: Restoration/.Service/Remodel Estimate: ORR Preliminary estirnate, subject to final sub-bids. APF" Subject tc) Fe�d Ins,' Dab'z�: Sig ne," .,..a....m .,» a .aw o .., . ,.'t t t f N++ ... na 6^ '� Home: (303) 231-9949 Cellular: (303) 829-4012 Cellular: (303) 919-6241 E-mail: terry@atrierican-restoration. C()M SKETCHI Living Room Height: S' ' 419.22 SF Walls 608.51 SF Walls & Ceiling 189,29 SF Ceiling 15329 SF Floor '1.t)3 SY Flooring 55.75 LF Floor Perimeter 513,17 F.,Fj" C.et1. Perimeter k._...e... .........„,p..... «:5 Via' ...._........„.„,„„.{ Window T X _ " V Opens into Exterior Window T X Y 9" Opens into Exterior Window 2'X Y " Opens into Exterior Window 2' X Y 9" Opens into Exterior Missing Wall - goes to Floor 2'5" X 6 13" Opens into KITCHEN DESCRIPTIO . �_ QNTY 1. R&R Batt stastalaatac>n - 12,. R313.._. �,.._,__. �____ �..._..._._ �..__.. �.._.. �..__._... ��.. . �..._.. �.,. .... � .._W.w__.�...._�...�...18929 SF 1 Remove 1 /2" drywall - hung, taped, floated, ready for paint, two layers with faarring strips 121T03 SF 3, Remove Furring strip - 1 " x 2" 60&51 SF 4. Clean stud wall 41922 S 5. Seal stud wall for odor control (shellac) 41912 Sp Ca. Remove Rigid foam insulation board - 2" - low density, walls had foam insulation 320.00 Sp` 7. Batt insulation - 4" - R13 32(),00 Sp 13. R&R Joist - floor or ceiling - 2x4 - w/lalockin , aide upgrade Cat} 00 F..,F 9 R&R Stud wall - 2" x 4" x 8'- 16" oc, aide upgrade * * ** * 1100 LF 10. R&R Header - triple " x 10 ", to support ceiling gist, code upgrade 11,00 LF 11, 2" x 4 " lumber (.667 BF per LF), laeaan supports 80,00 LL 12. 1/2" drywall - hung, taped, flcaaated, ready for paint 60&51 SF 11 Seal /prime then paint part of the walls and ceiling (2 coats) 44126 SF 14, R&R Paneling _ plywood w = /2x4 base & chair rail 60 00 SF 15. Seal & paint paneling 167,25 SF 16. R&R Wood door frame & tram - exterior - softwood. 7 1 /4x" wide, exterior door is ,a short door, has to 17JX) LF be custom made 17. R&R Header - double 2" x S", door header, code. upgrade 175 LF I& R&R 2" x 4" lumber (.667 BF per LF), trimmers for door, code upgrade 3101 U 19. R&R Exterior door slab - insulated metal or wood - High grade I AfO EA 20. R&R Door opening (jamb car. casing) - 32t "to36 "wide - paint grade I DO EA 2l. Door lockset & deaadbolt - exterior 1.001 EA ORR 6/22/2012 ,Page: 2 "" CONTINUED - Living Room I 22, R&R Door stop - wall or floor mounted 23. Paint door slab only - 2 coats (per side) 24. R&R Header - double 2" x ", 4 windows, code upgrade 25� R&R 2" x 4" lumber (.667 BF per LF), trimmers for windows, code upgrade ' R&R Vinyl window, single hung. 9-12 sf 27. R&R Window sill 28. Seal & paint window sill 29. R&R Baseboard - 2 1/4" 30. Paint baseboard - two coats 31, R&R Sheathing - plywood - 1/2" CDX 31 R&R Recessed light fixture 31 R&R Light fixture 34. R&R Heat/AC register - Mechanically attached 35< R&R Cold air return cover 36, R&R Carpet pad 37, Remove Carpet 38. Carpet 15 1 ,`c waste added for Carpet. 39. Deodorize building - Ozone treatment 40. Final cleaning - construction - Residential NOTES Z= 2,00 EA 1.00 EA 1100 LF 128,00 LF 4,00 EA 11001,,E 1100 LF 55.75 LF 55,75 LF 189.29 SF 100 EA 1.00 EA 1,00 EA 1.00 EA 189,29 SF 18919 SF 217,69 SF ORR 0+/2 2/213 12 Kitchen Height: 8' 273,89 SE Walls 105,63 SF Ceiling 379.51 SF Walls & Ceiling 105,63 SF Floor 11,74 SY Flooring 32.75 LF Floor Perimeter 46.17 LF C eil. Perimeter Missing Wall - goes to Floor 2' 5" X 6'8" Opens into LIVING-ROOM Door If 6" X 6 Opens into WATER-HEATER Door 2' 6 Cr' 8" Opens into Exterior Window Y ' Opens into Exterior Door 2' " X 6* 8 Opens into LAUNDRY-ROOM Door TX Cr' 8" Opens into BATHROOM Door ' h rr X Ci' " Opens into BE DROOM DESCRIPTION Q1 TY 41, R&R Batt insulation - 12" _ R38 IEI5.63 SF 42, Remove 1 /2 " drywall - hung, taped, (loaned, ready for paint, two layers with furring strips 759,03 S 43. Remove Furring strip _ 1 "» x 2" 379,51 SF 44. Clean said wall 273,89 SF 45. Seal stud wall for odor control (shellac) 273.89 SF 6, Remove Rigid foam insulation boa - 2" ° low density, walls had ffDam insulation 104.0() SF 47, Bait insulation - 4" - R 13 104,00 SF 48, R&R Joist - floor or ceiling - 2x4 - wA locking, code upgrade 39.00 LF 49. R&R Attic entrance cover and trim 1.00 EA % 112" drywall - hung, taped, floated, ready for paint 379,51 SF 51. Seal/prime their paint part cif the walls and ceiling (2 coats) 281,26 SF 52. R &R Food door fraarne & trim - exterior - softwood, 7 114" wide, exterior door is a short door, has to 17.00 LF be custom made 53. R&R Header - double 2" x " door header, code upgrade 3.75 l..F 54. R&R 2" x 4" lumber (.667 BF per LF), trimmers for door, code upgrade: 3100 LF 55, R&R Exterior door slab - insulated metal or wood - High grade 1.00 FA 56 R&R boor opening O amb & casing) - 32 "to36"wide - paint grade 1.00 FAA 57. Floor lockset & deadbolt - exterior 1.00 FAA 5S. 12&R Door stop _ wall t)r floor mounted 2,00 EA 59, Faint door slab only _ 2 coats (per sick) 1.00 E;A fat). R&R H double. 2" x 8",4 windows, code upgrade***** 12.00 LF 61 . R&R 2" x 4" lumber (.667 BF per LF), trrnrnaers for windows, code upgrade 1211,00 LF fat. R&R Vinyl window, single hung, 9-12 sf 1.00 EA 3. Add on for tempered Maass 9.00 SF ORR 6/22/2012 Pa x� 4,a.5 CONTINUED - Kitchen 102=3191M 64. R&R Window sill 65, Seal & paint window sill 66, Garbage disposer 67. Sink faucet - Kitchen 68, R&R Sink - double 69. R&R Cabinetry - upper (wall) units 70. R&R Cabinetry - lower (base) units 71. R&R Countertop - Least formed plastic laminate - Oversized. opening to living roorn 71 R&R Countertop - post formed plastic larninate 73. R&R 4" backsplash for flat laid countertop 74. Remove Range - freestanding - electric 75, (Install) Range - freestanding - electric 76. Remove Dishwasher 77, (Install) Dishwasher 713. Remove Refrigerator - top freezer - 14 to 18 cf 79. (Install) Refrigerator - top freezer - 14 to 18 cf 80, R&R Baseboard - 2 1/4" 81. Paint baseboard - two coats 81 R&R Recessed light fixture 83, R&R Light fixture 84� R&R Heat/AC register - Mechanically attached 85, R&R Sheathing - plywood - 1/2" CDX 86 R&R Underlayrnent - 1/4" 5 ply 87. Vinyl floor covering (sheet goods) 15 % waste added for Vinyl floor covering (sheet goods), 88. Deodorize building - Ozone treatment 89. Final cleaning - construction - Residential 90 R&R Sheathing - plywood - 3/4" CD X, remove flooring to gain access to plumbing system, one sheet of sub flooring EM 12,00 LF 1100 LF I DO EA I,00 EA 1.00 EA 5.00 LF 8,00 LF 4,00 LF 9.00 LF 9.00 LY 1,00 EA 1.00 EA 1,00 EA 1.00 EA I .00 EA 1.00 EA 32.75 LF 3175 LF I.00 EA 2,00 EA I ,00 EA 105,63 SF 105.63 SF 121.47 SF N ORR 6/22/2012 1 7 410 --1 V Laundry Room 191,94 SF Walls 5..-, 246.19 SF Walls& Ceiling 4 2 Cj 6.03 S Y Fl oori ng ' 2 29.50 LI Perimeter 2'8" MZM 54,25 SF Ceiling 54.25 SF Floor 27.00 LF Floor Perimeter Window 4' 10" X 2' 10" Opens into Exterior Door T 6" X 6' 8* Opens into KITCHEN Window 4' 10" X 2' 10" Opens into Exterior 91. R&R Batt, insulation - 12" - R38 91 Remove 112" drywall - hung, taped, floated, ready for paint, two layers with furring strips 93. Remove Furring strip - I" x 2" 94. Clean stud wall 95. Sea] stud wall for odor control (shellac) 96. Remove Rigid ("oani insulation board - 2" - low density, walls had foarn insulation 97. Batt insulation - 4" - R 13 98, R&R Joist - floor or ceiling - 2x4 - w/blocking, code upgrade 99, R&R Stud wall - 2" x 4" x 8'- 16" oc, code upgrade 100, 112" drywall - hung, taped, floated, ready for paint 101. SeaUpritrie their paint pail cif the walls and ceiling (2 coats) 101 R&RIleader- double 2" x 8"A windows. code upgrade 103, R&R 2" x 4" lumber (,667 BF per LF), trimmers for windows, code upgrade 104, R&R Vinyl window, horizontal sliding, 12-23 st' 105. R&R Window sill 106. Seat & paint window sill 107, R&R Baseboard - 2 114" 1 OK paint baseboard - two coats 109. Remove Washer/Washing Machine - Top-loading 110. Rernove Dryer -(Naas fit, R&R Light fixture III R&R fleat/AC register - Mechanically attached III R&R Cold air return cover 114. R&R Underlayrnent - 114" 5 ply 115. Vinyl floor covering (sheet goods) 15 % waste added for Vinyl floor covering (sheet (goods), 116. Deodorize building - Ozone treatment 117. Final cleaning - construction - Residential XM QTY 54.25 SF 492,39 SF 246,19 SF 191.94 SF 191,94 SF 320,00 SF 320.111) SF 4100 LF 8.00 LF 246,19 SF 165.19 SF 1100 LF 64.00 LF 100 EA 12,00 LF 12.00 LF 27,00 LF 27.00 LF I.00 EA 1.00 EA 1,00 EA I.00 EA 1,00 EA 5425 SF 62.39 SF W 612212012 Paae"6 CONTINUED - Laundry Room B191= 118, R Sheathing - plywood - 3/4" CDX, remove flooring to gain access to plumbing systern, one sheet ot'sub flooring 119, R Clothes dryer vent - installed IX R Cabinetry - full height nn it any Subroom 1: BEDROOM--CLOS 152.00 SF Walls 183.43 SF Walls& Ceiling T4 149 SY Flooring 21,08 LF Ccil, Perimeter Missing Wall T 7" X 8* Door 2 6" X 6 8" am QNTY 32, 00 SF I.00 EA 5.00 1.,E UMMM 135.78 SF Ceiling 135.78 SF Floor 43,00 LF Floor Perimeter Opens into KITCHEN Opens into Exterior 31.43 SF Ceiling 31,43 SF Floor 18,58 LFFloca-perimeter Opens into BATHROOM—CAB Opens into BEDROOM 111,1"", ..... .... .. ) 6/22/2012 P aj��. �7,,,,,/ T Bedrooni 336.97 SF Walls IT , 472,75 S1 Walls & Ceiling 15.09 SN'Flooring 48,00 LF Ceil, Perimeter Door 2f V X 6f 8ff Window 4' 10" X 2' 10" Subroom 1: BEDROOM--CLOS 152.00 SF Walls 183.43 SF Walls& Ceiling T4 149 SY Flooring 21,08 LF Ccil, Perimeter Missing Wall T 7" X 8* Door 2 6" X 6 8" am QNTY 32, 00 SF I.00 EA 5.00 1.,E UMMM 135.78 SF Ceiling 135.78 SF Floor 43,00 LF Floor Perimeter Opens into KITCHEN Opens into Exterior 31.43 SF Ceiling 31,43 SF Floor 18,58 LFFloca-perimeter Opens into BATHROOM—CAB Opens into BEDROOM 111,1"", ..... .... .. ) 6/22/2012 P aj��. �7,,,,,/ 12' V' I Suhroorn 2: BATHROOM-CAB Height: 8' afi== 52.76 SF Walls 57,73 SF Waal Is & Ceiling 0,55 SY Flooring 6 60 LF Ced. Perimeter NEdum 4.97 SF Ceiling 4.97 SF rtoor 6 60 LF Floor Perimeter Opens into BEDROOM-CLOS DESCRIPTION QNTY 121. R&R Batt insulation - 12" - R38 172.17 SF 122, Remove 1/2" drywall - hung. taped, floated, ready for paint. two lavers with toning strips 1427,82 SF 123. Remove Furring strip - I" x 2" 713.91 SF 124, Clean stud wall 541.73 SF 125. Seat stud wall for odor control (shellac) 541.73 SF 126 Remove Rigid foarn insulation board - 2" - low density. walls had foarn insulation 320X)0 SF 127. Batt insulation - 4" - R 13 320.00 SF 128. R&R Joist - floor or ceiling - 2x4 - w/blocking, code upgrade 48.00 LF 129, R&R Stud wall - 2" x 4" x 8'- 16" oc, code upgrade 16 00 LF 130. 1/2" drywall - hung, taped, floated, ready for paint 713.91 SF 131. Scaf/prime then paint part, ot'die walls and ceiling (2 coats) 50937 SF 132. R&R Header - double 2" x 8", 1 window, code upgrade ***** 6.00 LF 131 R&R 2" x 4" lumber (.667 BF per 11), trimmers for windows, code upgrade 32,00 LF 134, R&R Vinyl window, horizontal sliding, 12-23 st' I .(X) EA 135. R&R Window sill 6.00 LF 136. Seat & paint window sill 0.)0 LF 137. Interior door unit 2,00 EA 138, Paint door slab only - 2 coats (per side) 4.00 EA 139. Paint casing - two coats 6&00 LF 140. R&R Door knob - interior 2.00 EA 141, R&R Door stop - wall or prior mounted 100 EA 142, R&R Closet shelf and rod package 13.00 LF 141 Seal & paint wood shelving, 12"- 24" width 1100 LF 144. R&R Baseboard - 2 1/4" 6& 18 LF 145. Paint baseboard - two coats 6&18 LF 146 R&R Light fixture 1W EA 147, R&R Heat/AC rLgister - Mechanically attached 100 EA 148, R&R Cold art- return cover 1.00 EA 149. R&R Carpet pad 17117 SF 150. Remove Carpet 17117 SF OR 6/22/2012 Pa x v ,-" 11 CONTINUED - Bedroom DESCRIPTION QNTV 151. Carpet 198.00 SF 15 % waste added for Carpet. 152. Deodorize building - Ozone treatment 1377.40 CF 153. Final cleaning - construction - Residential 17117 SF � 1. 19 1 1 3 Bathroom Window Door I T OMEMIM 156 04 SF Walls 199,43 SF Walls Ceiling 4V SY Flooring 2 1.15? LF Ceil. Perinieter Subromn 1: TUB 70,76 SF Walls 80,05 SF Walls Ceiling 1.03 SY Flooring 8,85 LF Coil. perimeter HIMI&M ME= 43.38 SF Ceiling 43,38 SF Floor 19,82 LF Floor Perimeter Opens into Exterior Opens into KITCHEN ME= U9 SF Ceiling U9 SF Floor &85 LF Floor Perimeter Opens into BATHROOM DESCRIPTION 154. R&R Batt insulation - 12" - R38 155. Remove 1/2" drywall - bung, taped, floated, ready 1'()r paint, two layers with furring strips 156. Remove Furring strip - I" x 2" ORR QNTY 5168 SF 558 97 SF 279,48 SF poi'e 79 CONTINUED - Bathroom Wawa= EM 157. Clean stud wall 1523. Seal stud wall for odor control (shellac) 159, Remove Rigid foam insulation board - 2" - low density, walls had Hearn insulation 160, Batt insulation - 4" - R13 161. R&R Joist - floor or ceiling - 2x4 - w/blocking, code upgrade 162, 1-3/4" x 9-1/2" LVL lumber - material only, beam to support root" code upgrade 161 Carpenter - General Framer - pet hour, labor to install beam, 2 rnen x 2 hours, code upgrade, 164. R&R 2 x 4" lumber (.667 BF per LF), beam support, code upgrade 165, R&R Stud wall - 2" x 4" x 8'- 16" oc, code upgrade ****** 166, 1/2" drywall - hung, taped, floated, ready for paint, less tiled area 167. Seal/prime then paint part of the walls rand ceiling (2 coats) 16& R&R Header- double 2" x 8". 4 windows, code upgrade ***** lK R&R 2" x 4" lumber (.667 BF per LF), trimmers for windows, code upgrade 170. R&R Vinyl window, single hung, 9-12 sf 171. Add can fear tempered glass 171 Add on for obscure glass 171 R&R Window sill 174. Seal & paint window sill 175. R&R Cabinetry - full height unit 176, Remove Pedestal sink 177. Pedestal sink 178. Sink faucet - Bathroorn 179. Remove Bathtub 180, Batlitub 181. Tub/shower faucet 181 R&R 1/2" Cement board 181 R&R Tile shower - up to 60 SF 184, Remove Toilet 185, Toilet 186, R&R Medicine cabinet 187. R&R Bathroom mirror - w/metal frame - surface altd. - Sid grd 188. R&R Towel bar 189, R&R Toilet paper holder 190, R&R Towel ring 191. R&R Shower curtain rod ORR IM99MM 226.81 SF 226.81 SF 320.00 SF 320.00 SF 42.00 LF 18.00 LF 4.1711 HR 80,00 LF 15.00 LF 219,48 SF 193,48 SF 1100 LF 64,00 LF 1.1117 EA 8,00 SF 8X)0 SF 100 LF 3.00 LF 5.00 LF 1,00 EA 1,00 EA 1.070) EA 1.00 EA I .00 EA 1,00 EA 60,00 SF 1.00 EA 1,00 EA HA) EA 1,00 EA &00 SF 1.0107 EA I D0 EA 1.0107 EA 1.00 EA pzr CONTINUED - Bathroom 191 Interior door unit 193. Paint door slab only - 2 coats (per side) 194. Paint casing ® two coats 195, R&R Door knob - interior 19& R&R Door stop - wall or noor mounted 197, R&R Baseboard - 2 1/4" 198. Paint baseboard - two coats 199 R&R Light fixture 200, R&R Heat/AC register - Mechanically attached 2031. R&R Cold air return cover 202, R&R Underlayment - 1/4" 5 ply 201 Vinyl floor covering (sheet goods) 15 % waste added for Vinyl floor covering (sheet goods). 204. Deodorize building - Ozone treatment 205. Final cleaning - constrtiction - Residential 206 R&R Sheathing - plywood - 3/4" CDX. remove flooring to gain access to plumbing system 1= 20T R&R Batt insulation - 12" - R38 ORR Water heater closet 42.00 SF Walls 44,60 SF Walls& Ceiling 0,29 SY Flooring 6,50 LF Ced . Perimeter REMISR" MM 1,00 EA 2,00 EA 34.030 LF I M EA I M EA 28.67 LF 2&67 LF 2,00 E A 1,00 EA 1,00 EA 5168 SF 60,58 SF M 2..60 SF Ceiling 2,60 SF Floor 5.00 LF Floor Perimeter Opens hito KITCHEN ------Q 2.60 SF 6/22/2012 PaK." I CONTINUED - Water heater closet MEN= 9M 20& Remove 1/2" drywall - hung, taped, floated, ready for Paint. two layers with furring strips 2 Remove Furring strip - I" x 2" 2M Clean stud wall 211. Sea] stud wall for odor control (shellac) 211 Remove Rigid foarn insulation board - 2" - low density, walls had foarn insulation 213. Batt insulation - 4" - R13 214. R&R Stud wall - 2" x 4" x 8'- 16" oc, 7 If closet and 3 If knee wall 215. 1/2" drywall - hung, taped, floated, ready for paint 216. Seal/prime then paint part of the walls and ceiling (2 coats) 217, Remove Water heater - 30 , allon - Gas - 6 yr 2113, Water heater - 30 gallon - Gas - 6 yr 219, R&R Door opening Oamb & casing) - up tr> 32"wide - paint grade 220. Paint doo• /window trine &,jaurb - 2 coats (per side) 221. R&R Bifold door - full louvered - Single 221 Paint single bifold door - slab only - 2 coats (per side) 223. Paint casing - two coats 224. R&R Baseboard - 2 1/4" 225. Paint baseboard - two coats 226, R&R Underlayment - 1/4" 5 ply 227, Vinyl floor covering (sheet goods) 15 % waste added for Vinyl floor covering (sheet goods). 228. Deodorize buildirn - Ozone treatment 229. Final cleaning - construction - Residential MM ORR 6/22/2012 M 19 SF 44M SF 4100 SF 42,00 SF 320DO SF 320.00 SF 10,00 LF 44M SF 29M SF 1,00 EA I DO EA 1,00 EA 2AX) EA 2,00 EA 2,00 EA 34.00 LF 5 D LF 5M LF 160 SF 199 SF QNTY Pa I I Pa* CONTINUED - Attic 230. Clean floor or roof joist systern - Heavy 231, Seal attic framing (shellac) - 6 to 8/12 231 R&R Joist - floor or ceiling - 2x 12 - w/blocking - 24" oc, platt'orrn for furnace 233, 1 1 Sheathing - plywood - 3/4" CDX 234, Deodorize building - Ozone treatment 235, R&R Porcelain light fixture MMM 236. R&R Wood fence 5'- 6'high - cedar 237, R&R Post - wood - 4" x 4" fence grade cedar or eqUal Front Elevation 320.25 SF Walls 320-25 SF Long Wall 38.09 LF Ceil. Peritneter IM QNTY MOM SF 128M)0 SF 32.00 SF 32,00 SF 3840 00 CF I M EA Formula Elevation 20'7 1 i/16" x TV x 16' 20.66 LF Floor Perimeter 3M25 SF Short Wall 6/22/2012 Pa e"' g 238. Clean floor or roof joist system - Heavy. rafter tails, 239. Prime & paint exterior fascia - wood, 4% 6" wide 240. Prune & paint exterior soffit - wood 24 1. R&R Attic vent - gable end - metal - 14" x 24", combustion in for furnace in attic, code upgrade 241 R&R Fanfold foarn insulation board - 1/4" 243. R&R Furring strip - I " x 2", around windows and doors 244. R&R Trim board - I " x 4" - installed (cedar), window and door wrap 245. Seal & paint trim - two coats 246, R&R Siding - hardboard - lap pattern - 12" 247. Seal & paint wood siding 248, R&R Flashing, at masonary if needed 249. R&R Stearns door assembly 250, R&R Storm window - aluminum, 12-24 sf 251. MASONRY, repair stone work, open item 251 Two ladders with jacks and plank (per week) 253, R&R Exterior light fixture Right Elevation 217,00 SF Walls 21T00 SF Long Wall :3 1,00 LF Cei 1, Perimeter 254. Clean floor or roof joist systern - licavy, rafter tails. 255, Prime & paint exterior fascia - wood, 4"- 6" wide 256. R&R Soffit - box framing - Toverhang 257. Prime & paint exterior soft - wood 25& R&R Fanfold foam insulation board - 1/4" 259 R&R Furring strip - I " x 2", around windows and doors I 320,25 SF 61,00 SF 61.00 LF 61 .00 LF 320,25 SF 320.25 SF 20,00 LF 1.00 EA 2,00 EA 1,00 EA I.00 WK 1,00 EA Formula Elevation 31' x 7' x 0" :31.00 LF Floor Perimeter 217SX) SF Short Wall ORR 6/22t2012 P a I" CONTINUED - Right Elevation DESCRIPTION 260, R&R "Prim board - I" x 4" - installed (cedar), window and door wrap 261, Seal & paint trim - two coats 261 R&R Siding - hardboard - lap pattern - 12" 263. Seat & paint wood siding 264 R&R Flashing, at masonary if needed 265, R&R Srorrn window - almninurn, 12-24 sf 266. MASONRY, repair stone work, open item any Rear Elevation 192.73 SF Walls 192.73 SF Long Wall i. 21.51 LFCcil. perimeter Subroom 1: upper g ,able 51,65 SF Walls 51.65 SF Long Wall 21,51 LF Ceil. Perimeter J in 267. Clean floor or roof joist system - Heavy rafter tails, 268. Prime & paint exterior fascia - wood, 4"- 6" wide 269. prime & paint exterior soffit - wood am W= 28,00 LF 21i DO LF 217,00 SF 217,00 SF 20,00 LF 100 EA 1,(1(1 EA Formula Elevation 20' 7 15/16" x 7' 9 15/16" x 3' 20.66 LF Floor perimeter 192,73 SF Short Wall Formula Elevation 20'7 15/16" x V x 3' 2(1.66 LF Floor Peri meter 51,65 SF Short Wall — QNTY 36,00 SF 36.00 LF 36.00 SF 6/22/2012 paae— i 5 CONTINUED - Rear Elevation 270. R&R Attic vent - -able end - metal - 14" x 24", combustion an for furnace in attic, code upgrade 271. R&R Fanfold foarn insulation board - 1/4" 272, R&R Furring strip - 1" x 2", around windows and doors 271 R&R Trott board - I " x 4" - installed (cedar), window and door wrap 274, Seal & paint trim - two coats 2 R&R Siding - hardboard - lap pattern - 12" 276. Seal & paint wood siding 277, R&R Storm window - alutrunurn, 12-24 sf 278. MASONRY, repair stone work, open itern Left Elevation L 24167 SF Walls 2 SF Long Wall 31,1)11 LF Ceil. Perimeter 279, Clean floor or root'joist systcrn - Heavy, rafter tails, 280, Prinne & paint exterior fascia - wood, 4"- 6" wide 281. R&R Soffit - box framing - Toverhang 282. Prime & paint exterior soffit - wood 281 R&R Fanfold foarn insulation board - 1/4" 284. R&R Furring strip - I " x 2", around windows and doors 285, R&R Trim board - 1" x 4" - installed (cedar), window and door wra 286, Seal & paint trim - two coats N= 1 9.0111 SF 19.00 SF 19.00 LF 19. 00 LF 24438 SF 24438 SF 2.00 EA 1,00 EA Formula Elevation 3Ux T9 1-5/16" x 0" 31 DO LF Floor Perimeter 242.117 SF Short Wall ORR 6/22/2012 QNTY 64.00 SF 3100 LF 3100 LF &4DO SF 49.00 SF 49.00 SF 49.0.10) LY 49,00 LF Page: 16 CONTINUED - Left Elevation DESCRIPTION QNTY 287. R&R Siding - hardboard - lap pattern - 12" 242.67 SF 288, Seal & paint wood siding 24167 SF 289. R&R Flashing, at masonary if needed 20,(00 LF 2W R&R Storm window - aluminum, 12-24 st" 100 EA 291. MASONRY, repair stone work, open item ISX) EA 291 R&R Exterior fight fixture 1,00 EA DESCRIPTION QNTY 293, Dumpster load - Approx. 30 yards, 5-7 tons ot'debris 100 EA 294. Content Manipulation /Demo charge - per hour to pack out contents of home to gain access for demo. 65i 00 HR Of= DESCRIPTION QNTV 1 .95. Asbestos test fee - full service asbestos survey 1.00 EA 296. (Install) Temporary power - hookup 1,00 EA 297, Replace furnace and duct work 0,00 EA ORR 0/22/2012 CONTINUED - Miscellaneous DESCRIPTION 298, P1,UMBING. sub-bid, code upgrade 299. Pt,tJMBIN(., sub-bid, includes fixtures 300. E'lectrical (Bid Item), replace old electrical and bring up to code for whole house, new service and Lever bypass. 301. General Demolition - per hour to clean up the grounds - 2 for 4 hours 302, TEMPORARY REPAIRS, delivery fee for delivery and pickup of temp, toilet 303. Temporary toilet (per month) 304- GENERAL DEMOLITION, delivery fee for durripster 305. Dumpster load - Approx. 20 yards, 4 tons of'debris 306. Derno. permit and contractor fic, 307. Taxes, insurance, permits & fees (Bid item) 308. Engineering fees (Bid item) Grand Total Areas: 2,719,90 SF Walls 576.62 SF Floor 1,024,31 S1= F Loma all I- 576.62 Floor Area 834,06 Exterior Wall Area 0.00 Surface Area 0.00 Total Ridge Length ED 576 62 SF Ceiling 64,07 SY Flooring 1,024.31 SF Short Wall 635,67 Total Area 103.67 Exterior Perimeter of Walls 0,00 Number of' Squares 0.00 Total Hip Length 3,296,52 SF Walls and Ceiling 341.33 LF Floor Perimeter 389.80 LFCeil, Perimeter 1,695.59 Interior Wall Area 0.00 Total Perimeter Length RM 8,00 HR 2.00 EA 6DO MO 1,00 EA 4 00 EA 1,00 EA I.00 EA I.00 EA 6/22/2012 Pa96: 18,"; I I \ } � \ co / 4z � \�� / \ } � \ I I JI Jf" a 0 � d /` / 11 Michael P. Sheridan, P.E 9927 Hurty Avenue Conifer, Colorado $043 (303) 838-4707 U u. id CA MEMO For Wheatri••e Building Department Subject: Plan notes for remodel at 7380 W. 32 Ave, Unit B, Wheatridge, Colorado n (USGS 10-meter DE M, Feet) 5479 Snow Load Factor (Roof) 30 Snow Load Factor (Ground) i42,9 W i shower shall have non- a b so - t h e nt finish to 6' above floor. APPROVED Subject to Reid Inspections Whec Ridge Bu0ding Dept. Date Signe Plan checker Building Permit Application (Corn to jU highlighted areas) Address: city, state, €p: D City License # City License Mechanical: (Fully describe work to be performed - Attach additional sheet If necessary) Review Fee (due at time of submittal), Squares Gallons e t r a• City of rWh6atPjd e ,,OMMUNITY DEVELOPMENT i io 0 . II A # # . * • ..w, .. � �► (please a + Address: : City, State, it Reviewer Electrical:: Plumbing: Mechanical: INSPECTION RECORD INSPECTION LINE (303) 234 -5933 OCCLIPaRCVITVD@ Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. =� : ( y l� INSPECTOR MUST SIGN ALL SPACES "PERTAINING To THIS J OB FOUNDATION INSPE SPECTOR ITIALS COMMENTS:. Footings /Caissons " :Electrical Service Stemwall / (CEG). Co Encased Ground MDrain ..Rough Electric Reinforcing or Monol 'Rough Plumbing Weatherproof / .Frenc Gas Piping Sewer Service Lines:. INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO: FINAL INSPECTIONS. Rough Mechanical Water Service Lines' ** NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING: AND PUBLIC WORKS BEFORE A: '- CERTIFICATE OF OCCUPANCY •: IS ISSUED. FINAL .INSPECTION BY: THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A. CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. 'POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) .Heating (Underground) IWI Do NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED x- x ' ROUGHS 'Sheathings - 'Lath / Wall: tie :. :.Mid -Roof :Electrical Service ..Rough Electric 'Rough Plumbing Gas Piping INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO: FINAL INSPECTIONS. Rough Mechanical ** NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING: AND PUBLIC WORKS BEFORE A: '- CERTIFICATE OF OCCUPANCY •: IS ISSUED. FINAL .INSPECTION BY: THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A. CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. MBUVt INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING ?Framing Insulation Drywall Screw FINALS Electrical :Plumbing '. Mechanical:S Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO: FINAL INSPECTIONS. - Parking & Landscaping ** NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING: AND PUBLIC WORKS BEFORE A: '- CERTIFICATE OF OCCUPANCY •: IS ISSUED. FINAL .INSPECTION BY: THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A. CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER ♦ i CITY OF WHEAT RIDGE r Building Inspection Division 1 (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 235 -2857 Fax INSPECTION NOTICE Inspection Type: f '�_ 6or t 1 Job Address: ' 1 _3 `Ji D 6) A J Permit Number: Oq 1 r i ❑ No one available for inspection: Time Re Inspection required: Yes No When corrections have been made, call Date: Inspector: ✓ ✓ ✓; �Y fJ AM /PM at 303-234-5933 DO ♦ i CITY OF WHEAT RIDGE Building Inspection Division r (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 235 -2857 Fax INSPECTION NOTICE Inspection Type: 4 (f Job Address: - 7 ` O W 3 2A,21) .4 LA' Permit Number: 0 I G'771 F AJ,6 C ❑ No one available for inspection: Time AM /PM Re- Inspection required: Yes No When corrections have been made, tali fgfr3- inspection at 303 - 234 -5933 Date: `b € ' �) �i Inspector: DO NOT REMOVE THIS NOTICE ♦ ♦ CITY OF WHEAT RIDGE r Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: Y~z Tf 671 ~C~- Ty G"l~g . - c, r ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes ,:I)o When corrections have been m$be%''c~jat, for re-inspection at 303-234-5933 Date: Inspelcttoi DO NOT REM lS NOTICE INSPECTION RECORD Occupancy/TVDe "V INSPECTION LINE: (303) 234-5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS .JOB. FOUNDATION INSPECTIONS ' DATE INSPECTOR INITIALS. COMMENTS Footings/Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines FSIIR L~ Mi El R( R( r V V K.11W ~ UNi Kt I C UN I IL AUUVt.:"A5 6CtN. WUN1,11 ONCRETE SLAB FLOOR ectrical (Underground) umbing (Underground) rating (Underground) ° DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED )UGHS eathing th / Wall tie J-Roof :ctrical Service ugh Electric ugh Plumbing s Piping ugh Mechanical ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING. ming ulatlon wall Screw FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTEAUTHORIZATION OFA CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line r(303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: 6F.Jfo ;h Job Address: tJ '7xrf A D AU Permit Number: s1 r s t ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No "When corrections have been made, to re-inspection at 303-234-5933 Date:jInspect DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Mechanic PERMIT - 093098 PERMIT NO:.. 093098: `ISSUED: 10./07/2009 TOE ADDRESS: 7380: W. 32ND AVE " EXPIRES: 04/05/2010 DESCRIPTION::. Replace 80% furnace and electrical connection.: ***'CONTACTS Dwner 303/829-4012 Bob Orr SUB 303/458-5988 Josh Ward 01-8236 Applewood Plumbing Heating & y*PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION 0576-BLOCK/LOT#: 0/. t*FEE SUMMARY ESTIMATED PROJECT `VALUATION: ".5,720.00 FEES r .S t Permit Fee 40.00 Total Valuation .00 Use Tax 102.96 TOTAL 1142.96 ;onditions: lust comply w/ 2003..IRC & 2005 NEC. Subject to field inspections. I hereby certify that the setback distances :proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations. of the City of. Wheat Ridge or covenants, easements or restrictions. of record;. that all measurements shown, and allegations made are accurate;. that I have read and agree to abide by all conditions printed on this application and. that I assume full responsibility. for compliance. with the wheat 'Ridge Building. Code (I.B.C).and all other applicable Wh at Ridge Ordinances, for work under this permit. Plans subject to. field inspection. 9 ~ze Sig e of co tractor/owner to This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the 'State of >Colorado and to the. Zoning Regulations and Building Codes of Wheat Ridge,. Colorado or any other applicable ordinancesof the city. This permit shall: expire 180 days, from the issue date. Requests . for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if :suspension or `abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner 'shall be done that will' change the natural flow of water causing a drainage Sproblem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. The issuance. of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law; rule or regulation.` All plan rev' is subject to field inspections. (3 A ~ignatu ief Building Official -.date :NSPCTION REQUEST LINE: (303)234-5933 'BUILDING OFFICE: (303)235-2855'. tEQ. STS MUST BE MADE BY 3PM ANY BUSINESS. DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY., e ""E?r City of Wheat Ridge Building Division Date: 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-235-2857 Plan o Inspection Line: 303-234-5933 °toRfQ Permit#: Building Permit Application Rrapert Astd ess "M _ r( a .tp Property Owner (please print): !Rr~ 0Y f Phone: 3p3''6-?A `YQ[U Mailing Address: (if different than property address) Address: /""SS S 4b, kb Yd6-Z11 City State, Zip: 6-611,0400 CU -3 Qantract : G Contractor License#: P92-30 Phone: 3-)3-1/%- !~ZUk SIX lrContra04*G4 h) -ems Electrical City License Plumbing City License Mechanical City License Company: Company Company: 5e2~d2.-e- Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction value: $ "k, pr' FSESCrIptID`rt~-Ow07:[`i (as calculated per the Building Valuation Data sheet) -10k ?,-/Z) 661? -FUf~tc-ta--, Plan Review (due at time of submittal): $ Sq.Ft./L.Ftadded: Squares BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: OWNER) (C NTRACTOR) or PERSONAL REPRES TATIVE of (OWNEER) (CONTRATOR) PRINT NAME: 1 SIGNATURE:. Date: ~r °4 WHEgT~o. °Otoi;t~ ° Building Permit Application Date: Plan Permit #.0, PAi 60rty P;i("s: -73990 VVQ&-3~ h kk j Property Owner (please print): Sob 0 t Y, Mailing Address: (if different than property address) Address: &e3S oj4-h 5K o i At Ifs Ly& 9~ Phone ° 7 ~pG ~ City State Zip bl4A-e;hij ~A 1 SS~~nL~ Goitraetot: "r~ ~ Dl tVlr~~ ` t ~ Contractor License 6)11~(? r ~~''~bG Phone: 7 $ oontrac# * Svl l Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): " Construction Value: $ (as calculated per the Building Valuation Data sheet) DeS'CrjptlOnfwQ rk.: rCiAL-I'I'ICR:I C~t)r)C4, c'~ - fo r fV t r ~ Plan Review (due at time of submittal): $ cr'i oo~dt J Sq.Ft./L. Ft added: Squares BTU's Gallons Amps City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 Inspection Line: 303-234-5933 City of Wheat Ridge Residential Roofing PERMIT - 091071 PERMIT `NO: 091071- ISSUED: -08/03/2009 - ;I JOB ADDRESS: 7380 W 32ND AVE EXPIRES: 01/30/2010 i DESCRIPTION:. T/O reroof 18.sgs with GAF/ELK3 tab shingles ***CONTACTS ' owner 303/231-9949 Bob Orr sub X303/825-5273 08-0138 Colorado Roofing & Exteriors **'PARCEL INFO -ZONE CODE: UA -USE: UA SUBDIVISION:. .0576. ....BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: - 4,808.00 FEES `Permit. Fee` 144.70 Total Valuation .00 Use Tax 86.54 TOTAL 231.24 Conditions: 6 nail installation & mid-roof inspection required. Board sheathing spaced more than :a 1/2 of an inch apart .-requires plywood overlay on entire roof. Ice and water shield required from eave edge to 2'.`inside '.exterior walls. Subject to field inspections. K; I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable '.ordinances, rules or regulations of the City of Wheat Ridge. or covenants,. easements or restrictions of record; that all measurements shown, and allegations made are accurate; that T have read and agree to abide by all. conditions printed on this application. and that I assume full responsibility for compliance with. the Wheat Ridge Building Code. (I.B.C) and all other applicable wheat Ric nces, for work under this permit. Plans subject to field inspection. nature of cont1z-cEcr ate ' I. This permit was issued in accordance with the. provisions set forth in your application and is subject to the laws of the 'state-of Colorado and to. the :zoning Regulations and Building :Codes of Wheat Ridge, Colorado or any other :applicable 1%ordinances of the City. 2. This permit shall: expire 180days from the issue date. Requests for an extension must, be received prior to expirations ,9,.4. No work of any manner `shall be done that will change the natural flow of water causing a drainage problem. o1 5. Contractor shall notify the Building Inspector twenty-four {24} hours in : advance for 'all inspections and shall receive 6. The issuance of a permit or : the approval of : drawings . and specifications :shall not be construed to be a ' permit for, nor - ` an approval of, any. v'olation All bf. the provisions of the building codes or any other ordinance, law, rule or regulation. plan review.' s ct to field inspections. signature of Ch ding Official date INSPECTION9EQUEST.LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Z WE yo date. An extension may be granted at the discretion of the Building Official. 3. If this 'permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no - r; changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1)year, full fees shall ~ he. paid for anew permit. - written approval on inspection card before proceeding with successive phases of the. job. W HEgT AoF City of Wheat Ridge Building Division c 7500 W. 29th Ave., Wheat Ridge, CO 80033 v !m Office: 303-235-2855 * Fax: 303-235-2857 c~ ° Inspection Line: 303-234-5933 <ORPO Date: Q Plan Permit WG j -~-I Property Address: -7 3so W , -,:~z nA Au,-- Property Owner (please print):P)n)h n ('r Phone: 3o3-Z31 '119y9 Mailing Address: (if different than property address) Address: State, Contractor: Building Permit Application Contractor License Phone: 303 grLS- 5273 Sub Contractors: Electrical City License Company: Plumbing City License Company Mechanical City License Company: Exp. Date: Exp. Date: Exp. Date: Approval: Use of space (description): PG - Construction Value: $ y Description of work: 19 5f, S (as calculated per the Building Valuation Data sheet) S. y zsl* ~&A 3rab r 1,4 (/fad; Tore k d,r,„ r, Plan Review (due at time of submittal): $ Sq. Ft./L.Ft added: Squares (b BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements. shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: tt'''(~~VOWNER) (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER TRAT R PRINT NAME: l_.C YCylr7C~ SIGNATURE: Date: ZONING COMMENTS: Zoning: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY: FIRE DEPARTMENT:: ❑ approved w/ comments ❑ disapproved ❑ no review required City of Wheat Ridge Residential Plumbing PERMIT - 071195 PERMIT NO: 071195 ISSUED: 11/01/2007 JOB ADDRESS: 7380 W 32ND AVE EXPIRES: 04/29/2008 DESCRIPTION: emergency sewer line repair CONTACTS gc 303/696-9599 Steve Wakeham 01-9921 Pipeline Industries, Inc. owner 303/231-9949 Bob Orr . PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION: 0576 BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 2,500.00 FEES Permit Fee . 108.30 Total Valuation .00 W pg Use Tax . 45.00 TOTAL 153.30 Comments: Subject to.field inspection in yard only i hereby certify that the setback distances proposed by this permit application are accuraCe, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions o£ record; that all measurements shown, and allegations made are accurate; that i have read andagree to abide by all conditions printed on this application and at I assume full responsibility for compliance with the Wheat Ridge Huilding Code (I.B.C) and all other app ble Whe Ordinances, for work under this permit. Plans subject to field inspection. Si antr er /at~ 7 1. This permit was issued in accordance with the prwisions set forth in your application and is subject to the laws of the State of Colorado and to the 2oning Regulations and Huilding Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall espire 180 days from the issue date. Requests for an extension muat be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Huilding Inspector twenty-four (24) hours in advance for all inspections and shall receive written apprwal on inspection card before pmceeding with successive phases of the job. 6. The issuance of a permit or the a proval of drawings and specifications shall not be construed to be a pesmit for, nor an approval of, any viol i o e provisions of the bvilding codes or any oCher ordinance, law, rule or regulation. All plan review is subj c eld inspections. Signature o£ Chief Buildi~g OEEicial date - INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. oe'""E?rq City of Wheat Ridge Building Division oare: 7500 W. 291h Ave., Wheat Ridge, CO 50033 OffiCe: 303-235-2855 " Fax: 303-235-2857 Plan °~coriro° InspeCtion Line: 303-234-5933 Permit#: Building Permit Application Property Address: 73?Q w 32 " n cl q Property Owner (please print):~~ pb G Y Y Phone: 3• 2 S/~~l~f~f 9 Mailing Address: (if different than properfy address) Address: 7390 w City, State, Zip: 4/41ttw Contractoc / "p41i y Contractor License Phone:,? '(C-, (?6 ' q,r qcr Sub Contractors: Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): S(-'R Construction Vaiue: $ 2. Descriptlon of Wo~k: (as calculated pe~ the Building aluation Data sheet) irrntr,y,Mty sc,itbtr Y-e /F `'NY PlanReview(dueattimeofsu6miftal):$ Sq. Ft./L.Ft added: Squares BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or reslrictions of record; that all measuremenls shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicableWheat Ridge Ordinanws, for work under this permit. Plans subject to fl inspection. CIRLCEONE:: (OWNER (CONTRACTOR r PERSONALREPRE T TIVE (O TO SIGNA7URE: Date: (f•!•fJ7 PRINTNAME: ~'YS ♦ 01 ff) ZONING COMMENTS: Zoning: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: DEPARTMENT USE ONLY BUILDING DEPARTMENT COMMENTS: OCCUPANCY: _ Reviewer: - FIRE DEPARTMENT:: 0 approVed W/ Comments ❑ disappfoVed ❑ n0 fevieWlequifed Bldg Valuation: $ . . . . . , . . . COMMUNITY DEVELOPMENT DEPARTMENT Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office * (303) 235-2857 Fax 'j. f tOR INSPECTION NOTICE ~ Inspection Type: Job Address/Permit Number: ;75?0 ~ i G ~ t i ~ ~ t k ~ ~ ; ' ❑ No one available for inspection: Time la;,o AM/PM ~ Re-Inspection required: Yes , o-? ~ *When corrections have been made, call for re-inspection at 303-234-5933 ~ ~ Date: 4/,~17 Inspector: G r t ~ DO NOT REMOVE TH/S NOTICE ~ . 44_7p"~ eat Ridge Crty of Wh Residential Plumbing PERMIT - 071195 IIT NO: 071195 ISSUED: 11/01/2007 ADDRESS: 7380 W 32ND AVEEXPIRES: 04/29/2008 'RIPTION: emergency sewer line repair CONTACTS 303/696-9599 Steve Wakeham. r 303/231-9949 Bob Orr 01-9921 Pipeline Industries, Inc. * PARCEL INFO ONE CODE: UA UBDIVISION: 0576 USE: UA BLOCK/LOT#: 0/ * FEE SUMMARY Permit Fee Tota1 Valuation Use Tax TOTAL mencs: ject to.field inspection yard only ESTIMATED PROJECT VALUATION: 2,500.00 FEES 108.30 .00 45.00 153.30 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable dinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all. asurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this plication and that I aesume full responsibility for compliance with the Wheat Ridge Building Code (I.H.C) and all other plicable Wheat Ridge Ordinanres, for work under this permit. Plans aubject to field inspection. of contractor/owner daee This permit was issued in accordance witki the prwisions set forth in.your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes oE Wheat Ridge, Colorado or any other applicable ordinances of the City. This permiC shall expire 180 days from the issue date. Requests for an extension must be received prior to ezpiration date. An extension may be granted at the discretion of the Huilding Official. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, prwided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No workof any manner shall be done that will change the natural flow of water causing a drainage problem. Lontractor shall notify the Huilding Inspector twenty-four (24) hours in advance £or all inspections and shall receive written approval on inspection card before proceedingwith successive phases of the job. The issuance of a pesmit or the approval of drawings and specifications shall not be construed to be a pexmit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject to field inspectione. gnature of Chief Suilding Offi ~ date NSPECTION REQUEST LI .(3'(13)234-5933 BUILDING OFFICE: (303)235-2855 EQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.