E -Res. Water Heater Replcmnt PERMIT - 202100074
PERMIT NO: 202100074 ISSUED: 01/13/2021
JOB ADDRESS: 12270 W 35th Ave EXPIRES: 01/13/2022
JOB DESCRIPTION: Water Heater Replacement - 50 gal gas, 50000 BTU in mechanical room
*** CONTACTS ***
OWNER (720) 224-7700 RASMUSSEN DAVID S
SUB (303)422-8055 TONY J VECCHIARELLI 018805 TONY V PLUMBING & HEATING INC
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11700.00
FEES
Hot Water Heater 40.00
Total Valuation 0.00
Use Tax 35.70
** TOTAL ** 75.70
*** COMMENTS ***
*** CONDITIONS ***
Both the front and back of this permit are required to be posted on the job site at all
times. If the complete permit is not present, inspections WILL NOT be performed.
Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section
134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of
which require a building permit, occurs or where one or more rooms lawfully used for
sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen
feet of the entrance to each room lawfully used for sleeping purposes.
1* � 4 41'
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION:
City of Wheat Ridge
E -Res. Water Heater Replcmnt PERMIT - 202100074
202100074
12270 W 35th
Water Heater
Ave
Replacement - 50 gal gas,
ISSUED: 01/13/2021
EXPIRES: 01/13/2022
50000 BTU in mechanical
room
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any
�pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
01/13/2021
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
From: no-reolv(alci.wheatridae.m. us
To: CommDev Perm is
Subject: Online Form Submittal: Water Heater Replacement Permit Application
Date: Wednesday, January 13, 2021 11:39:20 AM
Water Heater Replacement Permit Application
This application is exclusively for RESIDENTIAL REPLACEMENT WATER
HEATERS - LIKE FOR LIKE ONLY.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN
ORDER FOR THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
replacement water
heater like for like?
PROPERTY INFORMATION
Property Address 12270 W 35th Ave
Property Owner Name Dave Rasmussen
Property Owner Phone 720-224-7700
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email
Address (Leave blank if
not known)
Attach City of Wheat
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
escodave0070@yahoo.com
CONTRACTOR INFORMATION
Contractor Business Tony V Plumbing & Heating
Name
Contractor's License 018805
Number (This is a 5 or
6 digit number for the
City of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-
4567)
Contractor Email
Address
Retype Contractor
Email Address
DESCRIPTION OF WORK
Number of gallons
t<18icaNVA-1810
cathie@tonyvph.com
cathie@tonyvph.com
1.9181
Is the water heater Gas
GAS or ELECTRIC?
If GAS, enter # of 50000
BTUs. If electric, enter
n/a
Where is the water mechanical room
heater located (for
example, basement,
crawlspace, etc)?
Project Value (contract 1700
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Person Applying for Anthony Vecchiarelli
Permit
Email not displaying correctly? View it in your browser.
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number:
❑ No one available for inspection: Time AM/PM
Re -Inspection required: Yes No
When corrections have been made, schedule for re -inspection online at:
http://www. ci. wheatridge. co. us/inspection
Date: fz r_. Inspector:
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge
E -Res. Boiler Replacement PERMIT - 202002449
PERMIT NO: 202002449 ISSUED: 11/23/2020
JOB ADDRESS: 12270 W 35th Ave EXPIRES: 11/23/2021
JOB DESCRIPTION: Replacing 140k BTU, 85% efficiency gas boiler in basement.
*** CONTACTS ***
OWNER (720) 224-7700 RASMUSSEN DAVID S
SUB (303)422-8055 TONY J VECCHIARELLI 018805 TONY V PLUMBING & HEATING INC
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11,083.00
FEES
Boiler Replacement 40.00
Total Valuation 0.00
Use Tax 232.74
** TOTAL ** 272.74
*** COMMENTS ***
*** CONDITIONS ***
Both the front and back of this permit are required to be posted on the job site at all
times. If the complete permit is not present, inspections WILL NOT be performed.
Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section
134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of
which require a building permit, occurs or where one or more rooms lawfully used for
sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen
feet of the entrance to each room lawfully used for sleeping purposes.
1* � � i City of Wheat Ridge
�� E -Res. Boiler Replacement PERMIT - 202002449
PERMIT NO: 202002449 ISSUED: 11/23/2020
JOB ADDRESS: 12270 W 35th Ave EXPIRES: 11/23/2021
JOB DESCRIPTION: Replacing 140k BTU, 85% efficiency gas boiler in basement.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
From: no-reolv(alci.wheatridae.m. us
To: CommDev Pets
Subject: Online Form Submittal: Furnace/Boiler Replacement Permit Application
Date: Monday, November 23, 2020 1:42:24 PM
Furnace/Boiler Replacement Permit Application
This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or
BOILER - LIKE FOR LIKE ONLY.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN
ORDER FOR THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
replacement residential
furnace or boiler like for
like?
PROPERTY INFORMATION
Is this Residential or Residential
Commercial?
Property Address 12270 W. 35th Ave.
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email
Address
Attach City of Wheat
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
David Rasmussen
720-224-7700
escodave0070@yahoo.com
CONTRACTOR INFORMATION
Contractor Business Tony V Plumbing & Heating
Name
Contractor's License 018805
Number (This is a 5 or
6 digit number for the
City of Wheat Ridge)
Contractor Phone
303-422-8055
Number (enter WITH
dashes, eg 303-123-
4567)
Contractor Email
cathie@tonyvph.com
Address
Retype Contractor
cathie@tonyvph.com
Email Address
DESCRIPTION OF WORK
What type of unit is
Boiler
being installed?
Number of BTUs
140000
What is the efficiency
85
(%) of the unit?
Is the unit GAS or
Gas
ELECTRIC?
Where is the furnace or
basement
boiler located (for
example, basement,
crawlspace, etc)?
Project Value (contract
11083
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Person Applying for Tony Vecchiarelli
Permit
Email not displaying correctly? View it in your browser.
1Zz?� V� S�4 A'e'
20/70�J5-0
INSPECTION
RECORD
INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection
INSPECTION REQUEST LINE: (303) 234-5933
Occitpanc y/y 1 ype
Inspections will not be performed unless this card is posted on the project site.
**Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.**
Inspector Must Sign ALL Spaces pertinent to this project
Foundation Inspections Date
Inspector Comments
Initials
Pier
Sewer Service
Concrete Encased Ground (CEG)
Plumbing
Foundation / P.E. Letter
Mid -Roof
UO Not Pour Concrete Prior To Approval Of Thp Ahnvp Insnacfinnc
Underground/Slab Inspections
Date Inspector Comments
Initials
Electrical
Comments
Sewer Service
Plumbing
Do Not Cover unaergrouncl or 13elow/in-Slab Work Prior To Annrnval Of Thp Ahnva Inanar4innc
Rough Inspections
Date
Inspector
Initials
Comments
Wall Sheathing
Mid -Roof
Lath / Wall Tie
Rough Electric
Rough Plumbing/Gas Line
Rough Mechanical
Rough Framing
Rough Grading
Insulation
Drywall Screw/ Nail
Final Inspections
Date
Inspector
Initials
Comments
Landscaping & Parking / Planning Dept.
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
ROW & Drainage / Public Works Dept.
Floodplain Inspection (if applicable)
Fire Inspection / Fire Protection Dist.
Final Electrical
Final Plumbing
Final Mechanical
Roof
Final Window/Doors
Final Building
NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate
of Occupancy is issued. Approval of the Final Building inspection c(ges notn�t�t�te autharla�tftn of occupancy.
F -Or 10W VORage Permits — riease ce sure that rough inspections are completed from tTieFi-t6TAfri6T'5nd electrical low voltage
by the Building Division.
Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued
Protect This Card From The Weather
L Lt City of Wheat Ridge
Residential Roofing PERMIT - 201704350
PERMIT N'O: 201704350 ISSUED: 07/18/2017
JOB ADDRESS: 12270 W 35th AVE EXPIRES: 07/18/2018
JOB DESCRIPTION: Residential Re -roof to install Malarkey Vista asphalt shingles - 33 sq
*** CONTACTS ***
OWNER (720)224-7700 RASMUSSEN DAVID S
SUB (303)791-2223 Eileen R. Ponzio 018699 RTP Roofing Co.
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT*: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,554.00
FEES
Total Valuation 0.00
Use Tax 200.63
Permit Fee 204.30
** TOTAL ** 404.93
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are
required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and
water shield is required. Eave and rake metal is required. A ladder extending 3 feet above
the roof eave and secured in place is required to be provided for all roof inspections.
Roof ventilation is required to comply with applicable codes and/or manufacturer
installation instructions, whichever is more stringent. In order to pass a final inspection
of elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer technical representative stating that "the application of the roof at (project
address) has been applied in accordance with the installation instruction for (roof
material brand name) roof covering" is required to be on site at the time of final
inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
A City of Wheat Ridge
V-
1�9
Residential Roofing PERMIT - 201704350
PERMIT NO: 201704350 ISSUED: 07/18/2017
JOB ADDRESS: 12270 W 35th AVE EXPIRES: 07/18/2018
JOB DESCRIPTION: Residential Re -roof to install Malarkey Vista asphalt shingles - 33 sq
*** CONTACTS ***
OWNER (720)224-7700 RASMUSSEN DAVID S
SUB (303)791-2223 Eileen R. Ponzio 018699 RTP Roofing Co.
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,554.00
FEES
Total Valuation 0.00
Use Tax 200.63
Permit Fee 204.30
** TOTAL ** 404.93
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are
required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and
water shield is required. Eave and rake metal is required. A ladder extending 3 feet above
the roof eave and secured in place is required to be provided for all roof inspections.
Roof ventilation is required to comply with applicable codes and/or manufacturer
installation instructions, whichever is more stringent. In order to pass a final inspection
of elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer technical representative stating that "the application of the roof at (project
address) has been applied in accordance with the installation instruction for (roof
material brand name) roof covering" is required to be on site at the time of final
inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
tiW.41
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION:
City of Wheat Ridge
Residential Roofing PERMIT - 201704350
201704350 ISSUED: 07/18/2017
12270 W 35th AVE EXPIRES: 07/18/2018
Residential Re -roof to install Malarkey Vista asphalt shingles - 33 sq
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
thisppermit. I further attest that I am le ally thorized to include all entities named within this document as parties to the work to be
performed tha l (work to beer�is c�closed in this document and/9f its accompanying approved plans and specifications.
Signature of OWNER or( CONTRACT0_R,(C> rcle one) Date
1. This permit was issued bi�lie-irrP�rmation provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to f any
inspection.
Signature of Cl ' iall Wt/Q� Date
REQUESTS MUST E BY 11:59PM ANY BUS ! SS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dane Lovett
-20 70 ��)--C)
From: no-reply@c i.wheatridge.co.us
Sent: Monday, July 10, 2017 12:23 PM
To: Permits CommDev
Subject: Online Form Submittal: Residential Roofing Permit Application
Categories: Danny
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number
Property Owner Email
Address
12270 West 35th Avenue
Dave Rasmussen
720-224-7700
barbara@rtproofingco.com
4
Do you have a signed Yes
contract to reroof this
property?
It will need to be
provided at the time of
permit pick-up.
CONTRACTOR INFORMATION
Contractor Name
Contractor's License
Number (for the City of
Wheat Ridge)
Contractor Phone
Number
RTP Roofing Company
018699
303-791-2223
Contractor Email Address barbara@rtproofingco.com
Retype Contractor Email barbara@rtproofingco.com
Address
DESCRIPTION OF WORK
Are you re -decking the No
roof?
Description of Roofing Malarkey Vista Shingles
Material
Select Type of Material: Asphalt
If "Other" is selected Field not completed.
above, describe here:
How many squares of the 33
material selected above?
Does any portion of the No
property include a flat
roof?
If yes, how many squares Field not completed.
on the flat roof?
TOTAL SQUARES of all 33
roofing material for this
proj ect
Provide additional detail House re -roof --low slope 2/12 pitch. Ice and Water Shield to be
here on the description of installed on the complete roof
z
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
Project Value (contract
value or cost of ALL
materials and labor)
9554.00
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant Barbara Neil
Email not displaying correctly? View it in your browser.
3
ZTRP RGO)FING CO.
SPECIALIST
Customer Info:
Job #: 3564
Rasmussen, Dave
12270 West 35th Avenue,
Wheat Ridge, CO, 80033
(720) 224 -7700 -mobile
S [kA\ \'I,
RTP Roofing Co.
4011 S. Federal Blvd. Sheridan, Co. 80110
Phone: (303) 791-2223
Fax: (303) 791-3534
Company Representative:
Ray Phillips
(303) 791-2223
ray@rtproofingco.com
Job Number: 3564
Description
Quantity
Unit
Price
Total
Permit Fee Permit Fee - City of Wheatridge
1
EA
$45.00
$45.00
R & R Remove and Re -Install Heat Cable (Front and Back sections), after
70
LF
$1.50
$105.00
new roof is installed. /riM�1c �'-�P,7` ,✓•�/f
30
LF
$8.25
$247.50
Remove Tear off - 1 layer, haul and dispose of shingles - Laminated or
33.33
SQ
$52.00
$1,733.16
equivalent
R & R Drip edge / Gutter Apron » 2"x4" » Dark Bronze
166
LF
$2.00
$332.00
R & R Rake Edge » 2"x2" » Dark Bronze
161
LF
$2.00
$322.00
Replace Ice & Water Shield - On Complete House - Low Slope 2/12 pitch
3400
SF
$1.00
$3,400.00
- Per last RTP - Roof Invoice on 3/8/2010
R & R Flashing - pipe hack » 3 in 1" a .g
- 4
EA
$35.00
$140.00
R & R Power Roof Vent -Oversized - RV144 PVe7414 `
1
EA
$250.00
$250.00
R & R Roof vent, Slant Back, Metal » Lomanco » 750 Style » Bronze
2
EA
$45.00
$90.00
R & R Continuous ridge vent, shingle -over style » TrimLine » 11" Ridge
46
LF
$7.75
$356.50
Vent
R & R Furnace vent, Rain Cap, 5" to 8"
1
EA
$75.00
$75.00
Charge Spray Paint (Penetrations)
8
EA
$0.00
$0.00
R & R Step flashing(!) » Step Flashing » 8"x8" Pre -Bent » Bronze
53
LF
$4.00
$212.00
R & R Re -flash Chimney 1
EA
$75.00
$75.00
R & R Re -Flash Swamp Cooler Q
1
EA
$75.00
$75.00
R & R Install New 2"x4" Metal Cap
50
LF
$2.00
$100.00
Replace Shingle- Laminated- Standard without felt a GAF HD ---------
36
SQ
$195.00
$7,020.00
Timberline/Tamko Heritage/O.C. Duration/Malarkey Vista -
H/R/S - Color
Roof - Estimate total: $14,330.66
Gutter & Downspout - Estimate t7( c'46 -5 -
Description
Quantity
Unit
Price
Total
R & R Remove gutters & downspout haul away
196
LF
$0.00
$0.00
R & R Aluminum Gutter- 5" » Lansing » 5" Alumminum .032 » White
166
LF
$5.75
$954.50
R & R Downspout - 3" x 4" » Lansing(!) » 3x4 Downspouts(!) » White
30
LF
$8.25
$247.50
R & R Install New Relief Gutter guard/screen - One section Back gutter
24
LF
$6.50
$156.00
Gutter & Downspout - Estimate total: $1,358.00
Separate Add On Options., to Base Price. (2 0'A_7 %
Description Quantity Unit Price 'Total
Replace Shingle- Laminated- Impact Resistant - Class #4 UL 2218 - 3-4- 36 SQ $0.00 $0.00
5/bids )> GAF » Timberline ArmorShield II --------- ADD + $1,440.00
Replace Shingle- Laminated- Impact Resistant - Class #4 UL 2218 - 3-4- 36 SQ $0.00 $0.00
i15/blOwen 0efi
Replace Shingle- Laminated- Impact Resistant - Class #4 UL 2218 - 3-4- 36 SQ $0.00 $mo
Separate Add On Options, to Base Price, total: $0.00
Total for all sections: $15,688.66
Total: E$1 51 688.66 j
RFP ROOFING COMPANY WARRANTY:
FROM THE DATE OfCOMPLETION, RTP ROOFING COMPANY HAS ATEN YEAR LABOR AND WORKMANSHIP WARRANTY ON
THE WORK PERFORMED.
COLORADO RIGHTS:
PER COLORADO LAW (SB -38) YOU HAVE A 72 HOUR RIGHT OF RECISSION AFTER SIGNING A CONTRACT ORAFTER
RECEIVING NOTICE lNWRITING THAT YOUR INSURANCE CLAIM HAS BEEN DENIED. YOUR ROOFING CONTRACTOR
CANNOT PAY ORWAIVE YOUR INSURANCE DEDUCTIBLE.
SEE ADDITIONAL TERMS AND CONDITIONS - SEE ATTACHED FORM.
RTP ROOFING COMPANY'S INSURER IS PINNACOL ASSURANCE FOR ALL OUR EMPLOYEES,
Comparj�r'Aut,harized Signature Date Customer Signature' Date
Customer Signature
This estimate was last edited by Pay Phillips 3} 791-2223, ray@rtproofingcn.com) on June 08, 2O17.The estimate
may be withdrawn if not accepted within ?4 days.
A i CITY OF WHEAT RIDGE
�(303)
Building Inspection Division
(303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: a
Job Address: a ��� % `s F)V C
Permit Number:/ -,5 -5
❑ No one available for inspection: TimeAf�fC%PM-
Re-Inspection required: Yes !No-?
When corrections have been made, call for re -inspection at 303-234-5933
Date:-Inspector:1
y,
DO NOT REMOVE THIS NOTICE
I i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: M I 0
Job Address: 112-17,10 A 5T4 ��'
Permit Number: 2,0 1042750
:uL_ �-Dt X10
❑ No one available for inspection: Time OM/M
Re -Inspection required: Yes (No)
When corrections have been made, call for re -inspection at 303-234-5933
Date: b i u 11-1 Inspector:
DO NOT REMOVE THIS NOTICE
Or Current Owner/Occupant
David Rasmussen
12270 W 35TH AVE
WHEAT RIDGE CO 80033-5210
Regarding Permit: 20070360; 8' x 151 storage shed
12270 W 35th AVE, Wheat Ridge, CO 80033-5210
Our Records indicate that the above noted permit was issued on 04/24/07. Our last
inspection related to that permit was on NONE.
Because of the inactivity on this permit, it will become void as of 12/31/2015.
Please contact this office within one week from the date of this letter to update us on
the status of this permit, or call for a final inspection on the property. You may call
303-234-5933 or request inspections online at www.ci.wheatridge.co.us. Information needed
are permit number, property address, type of inspection and date to be inspected.
If you do not contact this office, and wish to resume work at a later date, you will be
required to submit a new permit application, drawings with appropriate code edition
information and pay applicable fees. Incomplete or inactive permits may be reported to
agencies such as Jefferson County Assessor, title companies, etc., and could affect future
transactions related to this property.
Thank you for your cooperation concerning this matter. If we can answer any questions,
please don't hesitate to contact us at 303-235-2855, option 7.
Melissa Mackey
Senior Permit Technician
♦ ! i CITY OF WHEAT RIDGE
Building Inspection Division
j ( (303) 234 -5933 Inspection line
/(303) 235 -2855 Office • (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type: �
Job Address:
Permit Number:
❑ No one available for inspection: Time AM /PM
Re- Inspection required: Yes No
When corrections have been made, call for re at 303 234 -5933
Date: f / Inspector
DO NOT REMOVE THIS NOTICE
INSPECTION RECORD Occupancp/T
INSPECTION LINE: (303) 234 -5933
Inspections will not be made unless this card is posted on the building site
Call by 3:00 PM to receive inspection the following business day.
122 - Tn w _ . A?,4 - e> o - I AW 3
INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB
FOUNDATION INSPECTIONS
DATE
INSPECTOR INITIALS
COMMENTS:
Footings /Caissons
Stemwall / (CEG) Concrete
Encased Ground
5 _ - - /G'
y��
A /'L S� e , /,/L �e_S' 'v 4L /o
G P_
Reinforcing or Monolithic
U
�•�-
Rough Electric
Weatherproof /French Drain
Cs OL:f dLd'� GClt2 Ui =/../. ✓� "UC'n7 7� +�•1-
Rough Plumbing
Sewer Service Lines
-
Gas Piping
Water Service Lines
• -
Rough Mechanical
CONCRETE SLAB FLOOR
Electrical (Underground)
Heating (Underground)
ROUGHS
Sheathing
Lath / Wall tie
Mid -Roof
5 _ - - /G'
y��
A /'L S� e , /,/L �e_S' 'v 4L /o
G P_
Electrical Service
U
�•�-
Rough Electric
Building Final
Cs OL:f dLd'� GClt2 Ui =/../. ✓� "UC'n7 7� +�•1-
Rough Plumbing
Fire Department
-
Gas Piping
R.O.W & Drainage
• -
Rough Mechanical
Farling & Landscaping
-
ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING
Framing
Insulation
-
-
Drywall Screw
FINALS
Electrical
Plumbing
Mechanical
Roof
U
�•�-
Building Final
_
Fire Department
- -
R.O.W & Drainage
INSPECTIONS FOR PLANNING &a. ZONING, FIRE AND PUBLICE WORKS
SHOULD BE CALLED AT LEAST, ONE WEEK PRIOR TO FINAL INSPECTIONS.
Farling & Landscaping
-
"NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A
L CERTIFICP. TE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION
OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY.
OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED
PROTECT.THIS CARD FROM THE WEATHER
e ♦ i CITY OF WHEAT RIDGE
Building Inspection Division
r (303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax , "d
INSPECTION NOTICE
Inspection Type: /~i/1 11r}oF
Job Address: 1227t~) ()es 3Stc C
Permit Number: Fo~~ vq3
l7t~n,
.
11 r,
No one available for inspection: Time e` L,_ -AMf M
Re-inspection required: Yes No`
When corrections have been made, call for re-inspection at 303-234.5933
Date: Inspector: 9,/
DO NOT REMOVE THIS NOTICE
COMMUNITY DEVELOPMENT DEPARTMENT
of w"EgrP BUILDING INSPECTION LINE - 303-234.5933
a CITY OF WHEAT RIDGE .
7500 WEST 29THAVENUE
WHEAT RIDGE, CO 80033 - (30,{3.2735.28555x)
cUC ORP~~ ~4~'PL[CA
Property Own Q ( jx1~ CfSS x~
Property Address: //7nU
Contractor License No.: /v7V.~
Company: eo.0Atq
Building Permit Number: l (r)Al f )
Date:
j
Phone:~j~
Phoneme 7Q/ ~
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I. Build%ng Dept. Valuation Figure: $
1 hereby certify that the setback distances proposed by this permit application are
accurate, and do not violate applicable ordinances, rules or regulations of the City of Value:$ d'PG r 6
Wheat Ridge or covenants, easements or restrictions of record; that all measurements
shown, and allegations made are accurate; that I have read and agree to abide by all Permit Fee;$
conditions printed on this application and that I assume full responsibility for
compliance with the Wheat Ridge Building Code and all other applicable Wheat Plan Review Fee:$
Ridge Ordinances, for work under rtthis ermit.. III subject to feld inspection. Se ax,
(OWNER)( ONTRACTOR)' IGNED/.,.✓/I 6l_~'~ DATE' Total:$
Use of Space (description):
y cl c~~
Des ription of work: / le ce S 00
rs,ona( Sh(
C
Sq. Ft. added
Electrical License No: Plumbing License No: Mechanical License No:
Company: Company: Company:
Expiration Date: Expiration Date: Expiration Date:
Approval: Approval: Approval:
(1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of
Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of
the City.
(2) This permit shall expire if (A) the work authorized is not commenced within sixty (90) days from issue date or (B) the building
authorized is suspended or abandoned for a period of 180 days.-
(3) If this permit expires, a new permit.may be acquired for a fee of one-half the amount normally required, provided no changes
have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one
(1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit.
(4) No work of any manner shall be done that will change the natural flow, of water causing a drainage problem.
(5) Contractor shall notify the Building Inspector twenty-four (24) hours In advance for all inspections and shall receive written
approval on inspection card before proceeding with successive phases of the job.
(6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an
approval of, anyviolation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review
is subject to field Inspections:
Chief Building Official
. .
. .oF WHEqT'92
City of Wheat Ridge
Cot ORPQO Residential Electric PERMIT - 060569
PERMIT NO: 060569 ISSUED: 07/03/2006
JOB ADDRESS: 12270 35TH AV EXPIRES: 01/03/2008
DESCRIPTION: change service - 200 amperes
CONTACTS
owner 720/224-7700 David Rasmussen . .
PARCEL INFO
ZONE CODE: UA USE: UA
SUBDIVISION: UA BLOCK/LOT#: 0/
FEE SUMMARY ESTIMATED PROJECT VALUATION: 500.00
FEES
Permit Fee 30.55 Total Valuation .00 Use Tax 9.00 TOTAL . 39.55
Comments: .
must meet 2002 NEC -
Subject to field inpsection
I hereby certi£y that the setback distances proposed by this permit application are accurate, and do not violate applicable
ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all
measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this
application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other
applicable Wheat Ridge Ordinances, for workunder this permit. Plans subject to field inspection.
Signature of contractor/owner date .
1. This pesmit was issued in accordance with the provisions set forth in your application and is subject to the laws of the
State of Colorado and tothe Zoning Regulations and Huilding Codes of Wheat Ridge, Colorado or any other applicable
ordinances of the City. 2. This permit shall espire i£ (A) the work authorized is not commenced within sixty(60) days from issue date or (B) the
building authorized is suspended or abandoned for a period of 180 days.
3. If this permit expires, a new permit may be acquired £or a fee of one-halE the amount aormally required, provided no
changes havebeen or will be made in the original plans and specifications and any suspension or abandonment has noC
exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall
be paid for a new permit.
4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
5. Contractor shall notify the Building Inspector twenty-four (24) hours Sn advance for all inspections and sha11 receive
written approval on inspection card before proceeding with successive phases of the job.
6. The issuance of a permit or the al of drawings and specifications shall not be construed to be a permit for, nor
an approval of, an ati of the prov ions of the building codes or any other ordinance, law, rule or regulation.
All plan revie.W7~to~fi spections.
Signature of Chief Building Offical date
INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855
REQUESTS MUST BE MADE BY3PM ANY BUSINESS DAY EOR INSPECTION THE FOLLOWING BUSINESS DAY.
~F WHEqr ' •
~ Po City of Wheat Ridge Building Permit Number.
~ m Community Development Department Date:
coCORA00 3HNOR
. .SI1Cdkt..rs.S,fFGPf:w~S~.C~'~t"Ik AP~.5%..,[4ATION
Property Owner: a0- v i` c~,S H u e
PropertyAddress: f.'ZR/70 4✓ 357W /~✓C- rdAZr.Q'~c/61 ej 8ao33 Phone: fj2o'7.~~"77C'o
Contractor License No.: ~ 1/1(
Company: Phone:
OWNERICONTRACTOR SIGNATURE OF UNDERS7ANDING AND AGREEMENT I Buildinq Dept. Valuation Figure: $
I hereby certify that the setback distances proposed by this permit application are
accurate, and do not violate applicable ordinances, rules or regulations of the City of V3llle:$
Wheat Ridge or covenants, easements or restrictions of record; fhat all measuremenls
shown, and aliegations made are accurate; that I have read and agree to abide by all Pemut Fee:$
conditions printed on this application and that I assume full responsibility for
compliance with theWheat Ridge Building pde . )and all other applicable Wheat P1an ReviewFee:$
e(LE Ridge Ordinances, for work is pe it. a subject to field inspection. USe T3-X1:p~
(OWNER)(CONTRACTOR):SIGNED tY/"~T~/ DATE(7 Jf7-~~+ TOC6L:y
(OWNER)(CONTRACTOR):PRINTEDDOcU, DAT 'Q~ 30-~
Use of Space (description):
Description ofwork: L~~.<leyyc Ui,[!
Sq. Ft. added
Expiration Date: Expiration Date: Expiration Date:
Approval: Approval: Approval:
(1) This pertnit was issued in accordance with the provisions sef forth in your application and is subject to the laws of the State of
Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Coforado or any olherapplicable ordinances of
the City.
(2) This pertnit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building
authorized is suspended or abandoned for a period of 180 days.
(3) if this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes
have been orwill be made in the original plans and specifcations and anysuspension orabandonment has notexceeded one
(1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shali be paid for a new perznit.
(4) No work of any manner shall be done lhat will change the naturel flow of water causing a drainage problem.
(5) Confractor shall notity the Building Inspector (wenty-four (24) hours in advance for all inspections and shall receive wntten
approval on inspection card before proceeding with successive phases of thejob.
(6) The issuance of a permit or lhe approval of drawings and specifications shall not be consirued to be a permit for, nor an
approval of, anyviolation of the provisions of the building codes or any other ordinance, law, rule orregulation. All plan review
is subjectto field Inspections.
Chief Buildina Offcial
Electrical License No: Plumbing License No: Mechanical License No:
Company: Company: Company:
DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 13348
BUILDING INSPECTION LINE - 303-234-5933
Date
CITY OFWHEAT RIDGE : 1/17/02
~
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Property Owner. HAROLD DAWSON
Property Address : 12270 W 35TH AVE Phone : 237-9962
Contractor License No. : 20005
Company : Public Service Co. of CO Appliance Repair Phone : 871-7262
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and
do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
. application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE
Degcriptian : INSTALL 40 GAL WATER HEATER
Construction Value :
$599.00
Permit Fee :
$26.55
Plan Review Fee :
$0.00
Use Tax :
$8.99
Total
$35 54
Use:
CElectrical License No :
Company :
Expiration Date :
Approval :
Plumbing License No :
Company :
Expiration Date :
Approval:
Mechanical License No : 20005
Company : Public Service Co. of
CO Appliance Repair
Expiration Date : 8/3/02
Approval : OK/KS
(1) This permitwas issued in accordance with the provisions set Forth in yopur application and is subject to ihe laws of the State of Coloretlo antl to the Zoning
Regulations and Building Cotle oF Wheat Ridge, Colorado or any other applicable ortlinances of the Ciry.
(2) This permit shall expire if (A) the work au[horized is not commenced within sixty (60) days fmm issue date or (B) the builtling authorized is suspentletl or
abandoned for a period of 120 tlays (3) IFthis pertnit expires, a new permit may be acquiretl for a fee of one-half the amount normaliy required, provided no changes have been or will be matle in the
original plans and specifications and any suspension or abandonment has not exceedetl one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paitl For a new permit (4) No work of any manner shall be done [hat will change the naturel Flow of water causing a tlrainage pmblem. .
(5) ConVactor shall notify ihe Building Inspector hventy-four (24) hours in advance for all inspections and shall receive wririen approval on inspection cartl before
proceediing with successive phases oF the job.
(6) The issuance of a permit or the approval of tlrawings and specifications shall not be wnstrued to be a permit for, nor an approval of, any violation of the
provisions of th 'lding codes r any other ordinance, law, rule or regulatioa .
Chief B rYg I ispe ~
A
DEPARTMENT aF PLANNING AND DEVELOPMENT Building PermiC Number :
BUILDING INSPECTION DIVISION - 235-2855 '
, CITY OF WHEAT RIDGE Date I/ (16
1
WHFAT R1DGE, COV80215 ~
Property0wner:Walll AAu)Sa~
Property Address :/a 70 ~.tJ de. Wie, Yoa3-3 Phone;3o3-;?
Contractor License No. : a o 00 S
&o~a3
company: P ioSo S. FoX S~• ~c.J.C~a. Phone:.3o3-B7/-7-~76
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value :
sy~ ~
I hereby cerlity that the set6adc disWnces praposed hy this permB application are accurate, pertilit F2e : aG . SS
and do not vioWte applicable ordinances, rules at regulations of the City of Wheat Ridge or
covenants, easements or restdGions of recotd; lhat all measurements shown, and allegations
made are accurate; that I have read and agree lo a6ide by all wnditions pnnted on this Use Tax : S
application, and that I assume fuli responsibility far compliance wdh the VJheat Ridge Building
Code (U.B.C.) and alI oNer applicable at R' ge ordinance t for work under this p rtniL '
a ~ Total
(OWNER)(CONTRACTOR) SIGNE , a A7E I ! Usa :
Description :
y'~s-fn.f! Alo JA/ 4J~2. !~*R.
BUILDING DEPARTMENT USE ONLY
SIC : Sq. Ft :
Approval:
Zoning :
~ffdltfdlC~€n"~'9
Approval:
PIMb~J~is7
Approval:
Occupancy : Walis : Roof : Stories : Residential Units :
Elecfrical License No : Plumbing License No : Mechanical License No :
Company : Company : Company
Expiration Date : Expiration Date : Expiration Date :
Approval : Approval : Approval :
(1) This pertnd was issued In accaNance wiUt the pmvi5ions sd larth in yopur aOWimdon and is subjeC to the laws ol Ne SUIe ol CaloraCO atW !o the Zonunq
Regulatlons and BuitOiny Cade ot Wheat Ridge, CobrdOO a any oNer appli~0le ortlinances al the Ciry. (2) Thia pertnit stwp ezpire d(A) Ihe waAC aWwnzeG is nol mmrtiencetl wilhin s'ary (60) Oays Irom issue Cate ot (8) the buildlnQ auNaized is suspenEed w
abandaned fu a pMod o1720 days.
(3) If Nis pemiit ezp'ues, a new pertrul may 6e acqWred (or a lee a( one-hal( the amount normalty requi`eE, pmvided no tlwnges have been w wdl be made in the
original plans and apeafiqGons and any suspension a abarWOnment haa nat exceeded one (t) year. If changes ara maGe a i1 suspenaion a aEandonment
esceeds pfe (1) year, (ull leea shail he paW lor a new pertnit -
(4) No wark a( arry mamer stwll be Eane Ihat will change the ruw21 Ilow ot water rausing a drzinage pm0lem.
(5) Cunvaaar shau raup the Buiidinq Inspectcr twenry•1oa (24) hours in advana for ail inspeciions and shail receive wrinen approral an Inapection ard before
mceeEUng wilh su[cesshephaxa af ihe'Io6.
(6) ghe issuance ot a pemiit ar the appmval o( dnwings and spetificaliau shall rot be wnsW ed ta be a pertnil lw, nor an approral ol, anry vialatlon ol the pravisWne
. o( the huilaifq coda uany othu adirwice. Ww, iuie a reyuWGon. .
L
Chief Building Inspector For Mayor
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION
OF WHE4TA
~ ~c„ City of Wheat Ridge
°ot 0 R0160Res. Add Structure PERMIT - 070360
~RMIT NO: 070360 ISSUED: 04/24/2007
~B ADDRESS: 12270 35TH AV EXPIRES: 10/21/2007
;SCRIPTION: 8' x 15' storage shed
CONTACTS
"
r>:owner 720/224-7700 David
Rasmussen
PARCEL INFO * *
.
=ZONE CODE: R-lA
USE: UA
:'BUBDIVISION: UA
BLOCK/LOT#: 0/
FEE SUMMARY
ESTIMATED
PROJECT VALUATION: .00
FEES
'No Fees
.oa
PleaseNote:
TOTAL
.00
Owner / contractor is responsible for locating
m
ert
p
p
y
lines and cor.stn, tinnnmc.mm~nt.. ~
~
EComments :
CCACi
irag-Ea
approved plan and required devePmpment standards.
Tlie Cify is net responsible for inaccurafe information
AT : approved
submi:ted within the plan set and any cons!:vctiaa
Q;;,BM: Pending field inspections.
errorstesulting&ominaccarate;nicma*,ion.
hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable
dinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all
asurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this
plication that /I sume full responsibility for compliance with the Wheat Ridge Huilding Code (I.H.C) and all other
lica le e t R'~§e/6rdinances, for work under this permit. Plans subject to Eield inspection.
of contractor/owner
~ date
This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the
State of Colorado and to the Zoning Regulations and Building Codes o£ Wheat Ridge, Colorad6 or any other applicable
ordinances of the City.
This permit shall expire 180 daysfrom the issue date. Requests for an extension must be received prior to expiration
date. An extension may be granted at the discretion of the Building Official.
If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no
changes have been or will be made in the original plans and specifications and any suspension or abandonment has not
exceeded one (1) year. Tf changes have been or if suspension or abandonment exceeds one (1) year, full fees shall
be paid for a new permit.
No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractor shall notify the Huilding Inspector twenty-four (24) hours in advance for all inspections and shall receive
written approval on inspection card before proceeding with successive phases of the job.
The issuance of a permit or the approval of drawings and apecifications shall not be conserued to be a permit for, nor
an appr of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation.
All p VAeview is s14bj~ct to field inspections. .
of Chief Hdi1214n3~Of£-ied. date
)N REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855
MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Storage $hed Placement Permit
b~oo~
Storage Shed Placement Permit- NO FEE PERMIT
The Storage Shetl Placement Permit is for storage sheds that DO NOT exceed 120 square feet in floor area.
Property Owner: ~2~,,j
Property Address: /
,z 70 t,) 3 6-711 f?vc P60 3 2
Phone: ?,aW -~,>oo
Contractor: I Phone: I
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed for this permit application are accurate, and tlo not violate
applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of
record; that all measurements shown, and allegations made are accurate; that I have reatl antl agree to abide by
all conditions printetl on this application, and that I assume full responsibility for compliance with the Wheat Ridge
building Code (U.B.C.) and all other applicable Wheat Ritlge ortlinances, for work under this permit.
(OWNEWCONTRACTOR) Signature:
Date:
D
i
ti
Use:
escr
p
on:
Zonin
9:
Building
Setbacks:
S: ~
ide
Rear: ~
Front:
Sq. Ft.: 120
a
zoning Comments: ev t~,f- Q &
Approval:
Builtling Comments: ~-c
Approval:
1. No work of any manner shall be done that will change ihe naturai flow of storm water causing a drainage problem.
2. OwnedContractor shall no6fy the building department twenty-four (24) hours in advance for all inspections, and shall receive when
approvai an inspecGon.
3. The issuance of a permit or approval of drawings shaii not be construed to be a permit for, nor an approval of, any violation of the
provisions of the building codes or any ordinance, law, rule or regula6on.
4. Sheds must be properly and securely anchored at all corners.
PLEASE NOTE: Owner/Contractor is responsible for locating property lines and constructing improvements accortling to the approved
plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any
construction errors resul6ng from inaccurate information.
file:///EllwwwrooVcitydev/storage_shed_placement_permiLhtm (1 of 2) [702002 1035:46 AM]
Improvement Locatian Certificate
~ll~ans
LA!1'➢ C0:1'SL'LTA,\'TS
Giltians Land Consultants LLC
8474 W. Rice Avenue • Littleton, CO 30123 •303-972-6640
Address: 12270 W 35TH AVE
8orrower(s): N/A
Tifle search by:
Commitment No.:
Legai Description: PER CLIENT
Lot 38, Block 4,
APPLEWOOD VII.LAGE,
County of CONEJOS
State of COLORADO
F y1HEqT
~O ~ Rj0
i.
u !m
°~~i: ~~~+o°
Wheat Ridae Building
~ Approvecf
.iiidity oi permit: The iss
ind cromputations shall
any of the provisior
r'ermiis presuming to g
tiuilding codes nr
Yot a pertnit or approval o( plan
0 a permii for, or an approv3l of,
he buildinq code or of any Ciry c
"F,.. . ll8tc.• ,iO:....
~•.J
~
rlease rroee:
Ocanerlcontrac?eri,:Osoa'Isibtefurlocatin;proF.ert l
lines and ccr.s's_,c;ing imgroverr,eats ; ccordin,lg to thv
appraved p!zn recuired de ve.cgment sY;n»ards.
71:e C;!y i, ro? re,Por,si;;.e for inaccura±e informatian
suhmitfud within the plan sct ac;d any const:
errors resutting from inzecutaFe sfa:sl;;ion,
b { f
~4` t
- -t ~ 1
I 1 is'r N I
~
rA
_I
y '`k I M ',1 ~ ~ V
nent
i ~
specification~
R
ry vioiaFi6n to
inawces. J t,
~~~o~,sofAn~ W rj N ~ ~
(0 Z2,~
. n
i ~
L
cy
yf
;zn V,' ~
Terms and Conditions: As s[ated in the Certi£cah, "this is not a Lxnd Survey Plot or lmprocement Survey Plot". This Improve-
ment Loeation Certificate does not estabtish property corners and is intrnded onl}• to gice the generat situation of the currmt vis-
uaI improvemenU. Gilliane will not be liable for more [hat the cost of thie Improvement Loc»tion CertiTicate, and then only ro tbe
party specificalty shown hereon. Acceptanee andlor use of this lmprovement Location CertiTicate for anp purpose constitutes
agreement to all terms stated hereon."
Note: Unless othenvise noted, lot lines are based on apparent R.O. Ws and occupied lines.
On the basis of m}' knowledge, information and belief 1 hereby cedify that diis improvement locnlicro certificate was prepared (or
~
i
L~_.
~
,
~ - ~ - ~
; .
J
L Rt
g Department
'
DATL
val of s, sp
1~t~~ Qt7ienm Th~ iSSU~n~e of a~a a~ p~~~fic~a~S
~ ~A ~~t' Qlitafi ~all ~ ~ ? a an ~roval of, any violation to
oas
t~$eify~ tii ws
roioniofdhe{b'1Di ~Q or cance y l 'he prov sion s Of the
ermils presuming io giv~'~lh'` ,"Cit ~hail not be v21id.
L...IA:nn ~rv~oc pI
www.just-sheds.com - PLEASE READ THROUGH ENTIRELY
jllSt ShedS InC.
THESE PLANS ALLOW YOU TO BUILO ON
A CONCRETE SLAB, A WOODEN FLOOR
SUPPORTED BY CONCRETE PIERS, OR A WOODEN
FLOOR SUPPORTED ON SKIDS SEE OUR FREE OPl
LINE CONSTRUCTION GUIDE PoR MORE OETAILS
l-J L-I
,
i-- FRONT 10'-2" -1
SOME EMAIL SOFZWARE MAY
CHANGE SCALES SLIGHTLY
THESE PLANS ARE FOR
PERSONAL USE ONLY
O 2002 Just Sheds Inc.
All rights reserved
~
' LEFTSIDE S'-2"
WALL AND FLOOR
HEIGFff 9-8"
or S
WALL AND FLOOR
HEIGHT E- 0"
~
CONTENTS
1
PAGE
1
ELEVATIONS
PAGE
2
CROSSSECT10N1
PAGE
3
FLOOR PLAN C
O
O LEVATIONS
PAGE
4
CANCREfEPAD
COR
SCALE
PAGE
PAGEPAG E
5
67
SIdD FOUNDATION
W S PI~~ BU''
1/2 _ 1'. 0"
n„ N art
~i
ent
PAGE
AGE
8
9
RIGHT WALL D
FRONTWA LSAPpr
IZE
p•
P
PAGE
70
BACK W A
~Q'X~
PAGE
11
R4Ff P ENT
PLAN
PAGE
PAGE
i i~ . AL
13
FREEflAT
PAGE
14)
& i$Re issuance of a pe
li
W
pCCj¶C8I10[IS
PLUS
z
~r
M
s snall not be a permit
for, or an approval o, a
ny violalion lo
y
of an
of the builAing code o
i
i
o
1y
ons
s
any of the prov
~
'
is ons of lhe
pr
l h
-mits presuminq !n ol~,^
~ BACK 10'- 2" ~
STEPS FOR WALL FRAMING AND LUMBER CUTTING
1 sT Cut and layout at 16" O.C. the BPt for studs starting from the nght.
2rvo Cut and layout 1P1 for studs at 16 7/8" O.C. starting at S9
3RD Cut and nail all of the studs to BP'I.
4'" Nail TP1 to the studs in place, install wall sheeting as advised in the Construction Guide and fnish nailing as per specifications
NOTE! The 90° angle cuts needed are not listed in the angle column. The lengths mentioned here, when there is an angle cut, are always
measured at the longest points. When there is a second figure in the angle column, it is for the bottom or the nght end that needs [o be wt.
For more information on cutting lumber see section 4 of our Construction Guide.
FOR CL4F2fTY ON ANGLE CUTfING ORIEMATION SEE THE RAFfER CUTIING PAGE
DESCRIPTION CODE USE CUTLENGTH QUAN. ANGLE NOTES
BOTTOM PLATE BP1 2X4 95 1/8" 1
TOP PLATE 'iP1 2X4 701 1!4" 1 19'/19° Cut as shown
WALL STUD S1 2X4 60 3/8" 7 192 Cut as shown
WALL STUD S2 2X4 61 1/2" 1 792 Cut as shown
WALL STUD S3 2X4 65" 7 19' Cut as shown '~-"g
WALL STUD S4 2X4 70 5/8" 1 19' Cut as shown -
WALL STUD 55 2X4 76 1/8" 1 19' Cut as shown
WALL STUD S6 2X4 81 3/4" 7 19= Cut as shown
WALL STUD - S7 2X4 87 12" 7 19= Cut as shown
WALL STUD S8 2X4 92 1/2" 7 19' Cut as shown
WALL STUD S9 2X4 93 1/8" 1 19° Cut as shown
vfC R Xe,'
TYPICALLY SPACED WALL STUDS 16 7/8" O.C.
ALONG THIS ANGLEDTOP PLATE, WHICH WILL
ALIGN WITH 16' O.C. ON THE BOTfOM PIATE
S2
S1
THE SECTION OF WALL SHOWN HERE IS WTiHOUT SHEETING TO AID IN ILLUST
FOR THIS SHED PIAN IT IS RECOMMENDED THAT fi BE BUILT ON THE ROOR FlRST
STEP NUMBER 1 OF 4 PUT ASIDE AND INSTALLED LATER AS INSTALLATIOI~~P.iGi
WITH SHEETING IT WILL WEIGH ABOUT 110 LBS. uN
The fssuanceu'eyoI-~~~~
la ons shall nM be a permlt for, or an approval of, ~y violation to
the provisions of the building code a of any Ciry ordinances.
esuming to give autnn't" violate nr r.anr-l the provival d.of,~
lin9 coda,
STEPS FOR WALL FRAMING AND LUMBER CUTTING
15T Cut and layout at 16" O.C. the BP'I for studs starting from the left.
Zrvo Cuf and layout TP1 for studs at 16 7/8" O.C. starting at S9.
3flD Cut and nail ail of the studs to BPt.
4T" Nail TP1 to the studs in place, install wall sheeting as advised in the Construction Guide and finish nailing as per specifications.
DESCRIPTtON
CODE
USE
CUTLENGTH
QUAN.
BOTTOM PIATE
BP1
2X4
95 7/8"
1
TOP PLATE
TPi
2X4
101 1/4"
1
WALLSTUD
S1
2X4
603/8"
1
WALLSTUD
S2
2X4
611/2"
1
WALL STUD
S3
2X4
65"
1
WALL STUD
54
2X4
70 5/8"
1
WALL STUD
55
2X4
76 7!8"
1
WALLSTUD
S6
2X4
813/4"
1
WALL STUD
S7
2X4
87 72"
1
WALLSTUD
SS
2X4
921/2"
1
WALLSTUD
S9
2X4
931/8"
1
USe.27~
36
S7
SS
ANGLE NOlES
1g=/19° Cut as shown
79= Cut as shown
19' Cut as shown
79' Cut as shown
1g= Cut as shown
19, Cutasshown
ig° Cut as shown
19° Cut as shown
qg= Cut as shown
19' - Cut as shown
NPICALIY SPACED WALL STUDS 76 718" O.C. ALONG
THIS ANGLED TOP PLATE, WHICH WILL ALIGN WfTH
16" O.C. ON THE BOTTOM PIATE
~ S5
S4
S3
TP1
S2
S1
S9
:..;......v..:
~ Bp1 c Fp RIGHTSIDE
~~OHP~ WALLDETAILS
St~~CAL
WALLBUILDWGSTEP#2 yyheat Ridg~e Buildin ~F ~ZE
~~-t~SI m'
THE SEC710N OF WALL SHOWN HERE IS WITHOUT SHEETING TO AID IN IL T, . Ap prove 'I O'XH'
FOR THIS SHED PLAN ff IS RECAMMENDED THAT R BE BUILT ON THE FL UIL G STEP PLAN
NUMBER 20F 4 PUT ASIDE AND INSTALLED LATER AS INSTALLATION E 4 OF 4. F
WITH SHEEfING ff WILL WEIGH ABOUT 11 .,.TAr DA '
;idity of perrtVThe issuance of a permit or approvai ot pans,
d computations shall not be a permit for, or an approval of, any vi8ation lo
aay of Ihe provisions of the building code or of any City ordinances.
~rmits presuming ~c p:'.^ nnr~.~~. ~r ~~Nete nr zanoel the provisions of the
. ~nt h? valid.
-
,..,;ia_.....-
STEPS FOR WALL FRAMING AND LUMBER CUTTING
I s' Cut and layout BP1 and TPt, for studs and trimmer s[uds at opening locations (shown on the floor plan) at 16" QC.
Zrvo Cut and nail studs and trimmer studs to BP7 and then nail the studs to TPt. Cut remaining lumber.
3RD Naii in DL1 and WL1 on top of tnmmer studs and WS1 in beN✓een the window's TS2. Nail on the STP1.
4T" Nail the rest of the studs in place, install wall sheeting as advised in the Construction Guide and fnish nailing as per specifcations page.
DESCRIPiION
CADE
USE
CUT LENG7H
QUAN.
BOTTOM PLATE
BP7
2X4
9'-41/8"
1
TOPPLATE
7P7
2X4
9'-41/8"
1
SECOND TOP PLATE
STP1
2X4
9'-41/8"
1
WALLSTUD
St
2X4
91112
6
TRIMER STUD
TS1
2X4
81"
2
1RIMER STUD
TS2
2X4
81"
2
DOOR LINTEL
DL1
2X4
37 1/2"
2
VNNDOW LJNTEL
WL7
2X4
291/8"
2
WINDOWSILL
WS1
2X4
261/8"
1
CRIPPLE STUD
CS1
2X4
7"
3
CRIPPLES'fUD
CS2
2X4
22714"
1
WL1
TS2
WS1
C51
ANGLE NOiES
One 2x4 install on the flat side
iPi
DL1
S1
TS1
BP1
WALL BUILDING STEP tf 3
THE SECTION OF WALL SHOWN HERE IS WITHOUT SHEETING TO AID IN ILLUSTRATION. FOR
THIS SHED PLAN fi IS RECAMMENDED THAT ff BE BUILTAS BUILDING STEP NUMBER 3 OF 4
AND INSTALLED AS INSTALL4TION STEP NUMBER 1 OF 4.
WITH SHEETING fT 1MLL WEIGH ABOUi 110 LBS.
r~
1fL91NCi rr~ rovalofplans,spec0ications
~lidiry of permi . e issuance of a pertnil or app
A computations shall not be a permit for, or an approval $f, any violation to
any of lhe pmvisions of the buidin g n~P Or Oaanel hIe provi~s os ot the
ermits presuming Io 9!Vl -,r he valid.
building codec n' "
STEPS FOR WALL FRAMING AND LUMBER CUTTING
Isr Cut and layout at 16" O.C. the BP1 and TPt for studs stading from the right.
2"o Cut and nail studs to BPi and then nail to TP'I and then cu[ and nail STPt.
3R° Install v✓all sheeting as advised in the Construction Guide and fnish nailing as per specifications.
DESCRIPIION
CODE USE
CUTLENGTH
QUAN. ANGLE NOiES
BOTTOM PLATE
BP1 2X4
9'-4 7/8"
t
TOP PLATE
TPi 2X4
9'-4 7/8"
7
SECANDTOPPLATE
STP7 2X4
9'-41/8"
1
WALL STUD
S1 2X4
59 1/2"
8
U.Se~JTG
C,p,
TPi
S7
BP1
WALL BUILDING STEP # 4
'1
THE SECTION OF WALL SHOIMN HERE IS WRHOUi SHEETING TO AID IN ILLUSTRATION. FOR
THIS SHED PIAN IT IS RECAMMENDED THAT fi BE BUILTAS BUILDING STEP NUMBER 4 OF 4 BACK WALL
ANDINSTALLEDASINSTALLATIONSTEPNUMBER30F4. ~'p(ORp O gCALE
WITH SHEETING RNALL WEIGH ABOUT90 L&S. 0318" = 7'- 0"
Wheat Rid e Building ep?~*e
Approved PLAN
!iAity o( per'mit The issuance of a permit or approval of plans, specifcIP)ns
d computations shall not be a permil for, or an approval of, any violation to
any of the provisions of the building code or o( any Cily ordinances.
-mits presuming to give io vinlate or cancel the provisions of the
huiid;,a cnde< nrn!`,- ! 4.he City shail not be valid.
LUMBER CUTfING INFORMATION FOR ROOF SECiION
DESCRIPTION
SIZE
LENGTH QUAN
ANGLE NOTES
R4FfERS
2X4
CUT IN AN AMOUNT AND AS SHOWN ON THE RAFTER CUTfING PAGE
FRONT & BACK FASCIA
2X5
132" 2
CUT OR TRIM TO Fff AFTER IT IS INSTALLED
SIDEFASCIA
2X5
2
13'/19" MEASUREANDCUTTOLENGTH
LOOKOUT RAFfERS
2X4
14 112" 12
6 FOR FACH SIDE WALL
NOTE! The W angle cu[s needed are not lis[ed in the angie column. The lengths mentioned here, when there is an angle cut, are always
measured af the longest points. When there is a second fgure in the angle column, it is for the bottom or the righ[ end that needs to 6e cut.
For more infortna[ion on cutting lumber see section 4 of our Construc[ion Guide.
~ ~ e..
~ .
5~
ci norn rno onar nr
NPICAL',
RAFfER'
/
omputations shall not be a permil (or, or an approval of, any vio a ion to
any of the provislons o( Ihe building code or of any City ordinan .
,irs presumine c aivr nuU~ violate or cancel lhe provisions of the
.,.,a-: -..e, r It;. ..,1 nr o, ~ r,ty shall not be valid.
CUT 7 RAFfERS EACH OF THEM 112171 LONG
THEN CUTTHE BIRDS MOIJTH AND
THE 19 ° ANGLES AT EACH END AS SHONM 7ypICAL 2"X 5"
119 ° IS THE ANGLE USED FOR A 4112 ROOF PITCH) FASCIA BOARD FOR
THEFRONT,flACK
AND EOTH SIDES
19°ANGLE
~ BIRDS MOUTH
TYPICAL 2"X 4"
CAREFULLY CUT OUT
SUPPORTING WALL
4" FOR THE TOP OF THE
WITH 7/'16' ASPENITE
SUPPORTING WALLS AND
SHEETING
THEN CUT DOVVJ FOR THE SIDE
NOTE
NMEN CUTTING R4FfERS ff IS BEST
O0
TO CUT 1 FIRST AND THEN PLACE IT ON
4C
O
Y
ASATEMPLAT TOCUiTHE
THENUSEfi
Wheat Ridge Bui
REMAININGR4FfERSNEEDED
TYPICAL
ar
Fzorvr
AND
BACK
10'X8'
PLAN
RAFTER
CUTTMG
LAYOUT
_ SCALE
dity ot permit TFe issuance of a permit or approva~Tof pTans, specification
I computations shall not be a pertnit (or, or an approval of, anyii2ation tc
any ot ihe provisions nf the huilding code or ot any City ordinances.
~rmits presuminq to glvr a!nr.:,r.!, 1:1
vr!a!e nr cancel the provisions of lhe
hulidm~ moAC nr nir- :-i. es of 0 -e Cit; shall not tte valid.