Loading...
HomeMy WebLinkAbout7002 W. 35th Avenue1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge E -Res. Window Replacement PERMIT - 202101613 202101613 7002 W 35th Ave ISSUED: 07/27/2021 EXPIRES: 07/27/2022 Replace l window in the bedroom u -value .28 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any pplicab e code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 07/27/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge E -Res. Window Replacement PERMIT - 202101613 PERMIT NO: 202101613 ISSUED: 07/27/2021 JOB ADDRESS: 7002 W 35th Ave EXPIRES: 07/27/2022 JOB DESCRIPTION: Replace 1 window in the bedroom u -value .28 *** CONTACTS *** OWNER ( 3 0 3) 889-9145 BOOK THOMAS L SUB (303)421-7100 TED ROLAND 018516 K&H WINDOWS & EXTERIORS *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 878.00 FEES Window Replacement 50.00 Total Valuation 0.00 Use Tax 18.44 ** TOTAL ** 68.44 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Shawn George Permit Email not displaying correctly? View it in your browser. Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) Contractor Email Address Retype Contractor Email Address DESCRIPTION OF WORK What is being replaced Number of window and/or doors being replaced WIZI z8ar`z! sgeorge@khhomesolutions.com sgeorge@khhomesolutions.com NVA Morel, Location of bedroom window(s)/door(s) being replaced (for example, master bedroom, kitchen, bathroom, etc): What is the u -value of 0.28 the window(s)/door(s)? City of Wheat Ridge requires the u -value to be .30 or better on windows.. Attach copy of measure docs.odf window/door cut sheets showing sizes and u - value Project Value (contract 878 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Window/Door Replacement Permit Application Date: Tuesday, July 27, 2021 1:10:20 PM Residential Window/Door Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WINDOWS and DOORS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM AND WINDOW/DOOR CUTSHEET (SPEC SHEET) IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes replacement window(s) and/or door(s) like for like? PROPERTY INFORMATION Property Address 7002 West 35th Avenue Wheat Ridge, CO 80033 Property Owner Name Travis Book Property Owner Phone (303)889-9145 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email sgeorge@khwindows.com Address Attach City of Wheat cc form Ddf Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTRACTOR INFORMATION Contractor Business K&H Windows and Exteriors Name Contractor's License 018516 7002 W 35th Ave 202101057 Property Address Permit Number Permit Issued Date The City of Wheat Ridge _Third Party Form Check List pS 1 Page 1 of 2 Owner Information Property Owner Information L /Tr --ay __StsD Property owner Address 0 „p peke&-{- ,,5c o ca' C5003 --s Inspector Information Inspection Company Inspector Name Inspector Contact into, JBA Gary MarJ'v c«,� eneoxzea ...�1 ianwx..co so��e ce*nu.ua.a�eo a>foa:guymaNme�py�t� Inspector Statement and Acknowledgement I hearby acknowledge the roof I am inspecting is 6112 or over. All roofs that are under 6112 must be inspected by the City of Wheat Ridge Buiding Dept- * I hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all Pfty, of Wheat Ridge Pojicies and Procedure and Manufacturer's Inspector: le �/�/ _ - �=e,-• Date: G -3-2- I *1 hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the Cityof Wh e u m iv on inspection_ Propery Owned a j f = , mate,: Drop off in person Permit counter 2nd floor 7500 W 29th Ave Wheat Ridge CO 80033 Draft Date: 7126117 The City of Wheat Ridge In t Notes MID -ROOF -96- 2v2- 1 O TF,.'A El *stn [-I M,tA El WA El aria El tVA 0 MIA El NIA 0 wa. d tvA a NIA 0 lrtA ET�MA QIJ�VA El WA E wA LfrstA EA_*A 17,71 tc.'% El m -A E7 RiA i 7 %;Ia Asa: Ear i—rY�ass El aa� ass �F Lla ua$s. 1] Fait E] Fail ® Fail Q fail 1] Fail 0 Fail E] Fail Fail I'M 1; Fail L1 Fail 0 rail (] Fail 1] Fail i� Fail Q Fail El Kali El Fail 1] Fail Page 2 of 2 The City of Wheat Ridge Inspection Checklist Notes FIN Structural roof components Verify that no more than 2 layers of shingles exist Flashing for roof and vialls If neat sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Verify sheathing nail pattern (See Policy & Procedures) Crickets and saddles where needed Verify B vent must have hoot same gauge as pipe Verify gent caps Verify no flashings are damaged or rusted Step flashing shall be min. of 4x4 piece per shingle Verify scuppers allow for proper drainage Ice and water shield 2° in heated wall spaces Undedayments must follow 2492 IRC 12012 IBC Verify roof slope for proper drainage Dripiedge shall have min of 2" overlap Dripedge should extend doom min 2" past roof deck Dripedge shall be mechanicaly fastened 12" OC 90 LB mall roofing shalt not be applied to roof slopes less than 212 slope-, Exception, detached garages, patios, carports, opera on three sides with min_ slope of 1.12 Modified Bitumen, EPDM, TPO min stope 174:12 slope Above roof insulation R-25 Below roof residential R-38 Below roof commercial R-32 Modified Bitumen, EPDM, TPO min slope 114:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the ,address on the letter for final inspection =ate i Fos Me roof shingles shall not be installed on slope less 3_ R. rail !Metal voile flashing shalt be the same material as roof pass 0ail Metal valley Shing shall extend a min of 8" from the centerline N a min_ of 314 " high splash diverter rib built-in at the flow line with sections overlapping a --a min. of 4" aai; Clay ani Slopes 4:t Company Name: JBA CONSULTIN Inspector Signature.( Date of MID -ROOF Inspecti aL 2na_�_ e file shall have a min. 2-112:12 shape under require double underlaym,ent CompanyName: JBA NSULT NG Inspector Signature: Date of FINAL Inspection: l Z - 26 2 fio f Inspection 1] UJA —f r Fail El wA E.E" Py E] Fail El "tA IyFa$ M Fail 0+vA isvr-i'ust E] Fall rq-pim E] Fail O TF,.'A El *stn [-I M,tA El WA El aria El tVA 0 MIA El NIA 0 wa. d tvA a NIA 0 lrtA ET�MA QIJ�VA El WA E wA LfrstA EA_*A 17,71 tc.'% El m -A E7 RiA i 7 %;Ia Asa: Ear i—rY�ass El aa� ass �F Lla ua$s. 1] Fait E] Fail ® Fail Q fail 1] Fail 0 Fail E] Fail Fail I'M 1; Fail L1 Fail 0 rail (] Fail 1] Fail i� Fail Q Fail El Kali El Fail 1] Fail Page 2 of 2 The City of Wheat Ridge Inspection Checklist Notes FIN Structural roof components Verify that no more than 2 layers of shingles exist Flashing for roof and vialls If neat sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Verify sheathing nail pattern (See Policy & Procedures) Crickets and saddles where needed Verify B vent must have hoot same gauge as pipe Verify gent caps Verify no flashings are damaged or rusted Step flashing shall be min. of 4x4 piece per shingle Verify scuppers allow for proper drainage Ice and water shield 2° in heated wall spaces Undedayments must follow 2492 IRC 12012 IBC Verify roof slope for proper drainage Dripiedge shall have min of 2" overlap Dripedge should extend doom min 2" past roof deck Dripedge shall be mechanicaly fastened 12" OC 90 LB mall roofing shalt not be applied to roof slopes less than 212 slope-, Exception, detached garages, patios, carports, opera on three sides with min_ slope of 1.12 Modified Bitumen, EPDM, TPO min stope 174:12 slope Above roof insulation R-25 Below roof residential R-38 Below roof commercial R-32 Modified Bitumen, EPDM, TPO min slope 114:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the ,address on the letter for final inspection =ate i Fos Me roof shingles shall not be installed on slope less 3_ R. rail !Metal voile flashing shalt be the same material as roof pass 0ail Metal valley Shing shall extend a min of 8" from the centerline N a min_ of 314 " high splash diverter rib built-in at the flow line with sections overlapping a --a min. of 4" aai; Clay ani Slopes 4:t Company Name: JBA CONSULTIN Inspector Signature.( Date of MID -ROOF Inspecti aL 2na_�_ e file shall have a min. 2-112:12 shape under require double underlaym,ent CompanyName: JBA NSULT NG Inspector Signature: Date of FINAL Inspection: l Z - 26 2 A i City of Wheat Ridge 19 Residential Roofing PERMIT - 202101057 PERMIT NO: 202101057 ISSUED: 05/19/2021 JOB ADDRESS: 02 W 35th Ave EXPIRES: 05/19/2022 JOB DESCRIPTION: Reroo£ install 26 sq in 0_C. Oakridge Estate gray asphalt shingle on a 16:12 pitched roof on house, garage and shed. *** CONTACTS *** OWNER (303)889-9145 BOOK TRAVIS SUB (303)421-7100 TED ROLAND 018516 K&H WINDOWS & EXTERIORS *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / EARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,628.79 FEES Total Valuation 0.00 Use Tax 139.20 Permit Fee 156.75 ** TOTAL ** 295.95 *** COMMENTS *** *** CONDITIONS *** ALL PITCHED ROOFS REQUIRE A MIDROOF INSPECTION REGARDLESS OF PITCH. FOR ROOF PITCH 6/12 AND OVER: Midroof & Final Roof inspections for ROOFS with 6/12 PITCH & OVER REQUIRE A 3RD PARTY INSPECTION. The 3rd party inspection report must be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with Building Division Policy BD -18-001 for Balanced Ventilation Systems, or manufacturer installation instructions, whichever is more stringent. MIDROOF & SHEATHING: Effective December 1, 2014, asphalt shingle installations require an approved mid -roof inspection, conducted when 25-750 of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75% of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. LADDER MUST BE SET FOR ALL ROOF INSPECTIONS: A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. COMMERCIAL ROOFS: In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. 1* � � i City of Wheat Ridge �� Residential Roofing PERMIT - 202101057 PERMIT NO: 202101057 ISSUED: 05/19/2021 JOB ADDRESS: 7002 W 35th Ave EXPIRES: 05/19/2022 JOB DESCRIPTION: Reroof install 26 sq in O.C. Oakridge Estate gray asphalt shingle on a 6:12 pitched roof on house, garage and shed. *** CONTACTS *** OWNER (303) 889-9145 BOOK TRAVIS SUB (303)421-7100 TED ROLAND 018516 K&H WINDOWS & EXTERIORS *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 61628.79 FEES Total Valuation 0.00 Use Tax 139.20 Permit Fee 156.75 ** TOTAL ** 295.95 *** COMMENTS *** *** CONDITIONS *** ALL PITCHED ROOFS REQUIRE A MIDROOF INSPECTION REGARDLESS OF PITCH. FOR ROOF PITCH 6/12 AND OVER: Midroof & Final Roof inspections for ROOFS with 6/12 PITCH & OVER REQUIRE A 3RD PARTY INSPECTION. The 3rd party inspection report must be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with Building Division Policy BD -18-001 for Balanced Ventilation Systems, or manufacturer installation instructions, whichever is more stringent. MIDROOF & SHEATHING: Effective December 1, 2014, asphalt shingle installations require an approved mid -roof inspection, conducted when 25-750 of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-750 of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. LADDER MUST BE SET FOR ALL ROOF INSPECTIONS: A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. COMMERCIAL ROOFS: In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. 1* � � i City of Wheat Ridge �� Residential Roofing PERMIT - 202101057 PERMIT NO: 202101057 ISSUED: 05/19/2021 JOB ADDRESS: 7002 W 35th Ave EXPIRES: 05/19/2022 JOB DESCRIPTION: Reroof install 26 sq in O.C. Oakridge Estate gray asphalt shingle on a 6:12 pitched roof on house, garage and shed. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 05/19/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Roofing Permit Application Date: Wednesday, May 19, 2021 10:53:52 AM Roofing Permit Application THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this property Residential Commercial or Residential? How many dwelling Single Family Home units are on the property? PROPERTY INFORMATION Property Address 7002 W 35th Ave Property Owner Name Tom Book Property Owner Phone 303-889-9145 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? CONTRACTOR INFORMATION Contractor Business K&H Windows & Exteriors Name Contractor's License 018516 Number Contractor Phone 720-420-1727 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email rrobinson@khwindows.com Address Retype Contractor Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" rrobinson@khwindows.com DESCRIPTION OF WORK TOTAL SQUARES of 26 the entire scope of wo rk: Project Value (contract 6628.79 value or cost of ALL materials and labor) Are you re -decking the No roof? Is the permit for a flat Pitched roof (2:12 pitch or greater) roof, pitched roof, or both? (check all that apply) What is the specific 6/12 pitch of the PITCHED roof? How many squares are 26 part of the PITCHED roof? Describe the roofing Tear out and install 26 sq in O.C. Oakridge Estate gray materials for the PITCHED roof: Type of material for the Asphalt PITCHED roof: Provide any additional This is for a house, shed, and garage detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Rachael Robinson Permit Email not displaying correctly? View it in your browser. City of Wheat Ridge E -Res. Water Heater Replcmnt PERMIT - 202100598 PERMIT NO: 202100598 ISSUED: 04/01/2021 JOB ADDRESS: 7002 W 35th Ave EXPIRES: 04/01/2022 JOB DESCRIPTION: Replace 50 gallon gas water heater, 36k BTU in basement *** CONTACTS *** OWNER (303) 889-9145 BOOK TRAVIS SUB (303)280-5765 LARRY BENAVIDEZ 100318 SQUEAKS SERVICES *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11752.00 FEES Hot Water Heater 40.00 Total Valuation 0.00 Use Tax 36.79 ** TOTAL ** 76.79 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge E -Res. Water Heater Replcmnt PERMIT - 202100598 202100598 ISSUED: 04/01/2021 7002 W 35th Ave EXPIRES: 04/01/2022 Replace 50 gallon gas water heater, 36k BTU in basement I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 04/01/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Water Heater Replacement Permit Application Date: Wednesday, March 31, 2021 12:27:01 PM Water Heater Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WATER HEATERS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes replacement water heater like for like? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address (Leave blank if not known) Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 7002 W 35th Ave 10MISM66.1 3038899145 Field not completed. CONTRACTOR INFORMATION Contractor Business Squeaks Services Name Contractor's License 100318 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) Contractor Email Address Retype Contractor Email Address DESCRIPTION OF WORK Number of gallons t<18101-18WO.17 workorder@squeaksservices.com workorder@squeaksservices.com 1.9181 Is the water heater gas GAS or ELECTRIC? If GAS, enter # of 36000 BTUs. If electric, enter n/a Where is the water basement heater located (for example, basement, crawlspace, etc)? Project Value (contract 1752.0 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Permit Leah Benavidez Email not displaying correctly? View it in your browser. ' DEPARTMENT OF PLANNING AND DEVELOPMENT • BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner : Building Permit Number : 12352 Date : 6/20/2001 Property Address : 7002 W 35TH AVE Phone : 239-8869 Contractor License No. : 19312 Company : Deer Creek Plumbing Phone : 697 5883 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurete, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE Description : INSTALL 40 GAL WATER HEATER Construction Value : $300.00 Permit Fee : $23.50 Plan Review Fee : $0.00 Use Tax : $4.50 Total: $28.00 Use: - ~Ii3S~ Electrical License No : Company: Expiration Date : Approval : Plumbing License No : Company: Expiration Date : Approval: Mechanical License No : Company: Expiration Date : Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning : Regulations and Building Code of Wheat Ridge, Coloredo or any other applicable ordinances of the City~. (2) This permit shall expire if (A) the work authorizetl is not commencetl within sixty (60) days from issue tlate or (e) the building au[horized is suspended or abandoned for a period of 120 tlays . (3) If ihis permit expires, a new pertnit may be acquired for a fee of one-half the amount normally required, pmvitled no changes have been orwill be made in ihe original plans and specificalions and any suspension or abandonment has not exceedetl one (1) year. If changes are made or if suspension or abantlonment exceeds one (1) year, full fees shall be paid for a new permi[. (4) No work of any manner shall be done ihat will change the naturel flow of water causin9 a dreinage problem. (5) Contractor shall notify the Builtling Inspectortwenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediin successive hases of [hejob. (6) The is e approval of drawings and specifications shall not be construetl to be a permit for, nor an approval of, any violation of the provisions of the ~ in tl r other ordinance, law, rule or regulatiort . Chief Building Ins'~Sector DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 APPLICATIo N Property Owner: Dkb~kle- bQQl(l- Property Address :~7oQ&w. Contractor License No. : ~q 3 ~ Z Company : Phone: Phone : ~~1' Cj 8'n OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value S ()C.) `t I hereby certify that the setback distanees proposed by this permit application are aecurete, Pgfrtllt F0E : and do not violate appiieable ordinances, rules or regulations of the City of INheat Ridge or G~ Ot ~ sd covenants, easements or restridions of record; that all measurements shown, and allegations made are accurete; that I have read and agree to abide bX Sil conditions printed on this Use Tax : application, and that 1 assume full responsibility for compharlce wfth the Wheat Ridge Building Code (U.B.C.) and all other appliwbie Wheat Ridge ordinances, Por work under this pertnR. TOtal : (OWNER)(CONTRACTOR) SIGNED U SB : Description : \ BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval Zoning : BIIRBfii~T~ Approval: Approval : Occupancy : Walls : Roof : Stories : Residentiai Units : Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiretion Date : Expiration Date : Expiration Date : Approval: Approval: Approval: (1) This permit was issuetl in aocortlance with the provisions set forth in yopur appliwtion anA Is subject to the laws of the State ot Cobredo and [o the Zoning Reguiations and Building Cotle ot Nfieat Ridge, Colorado or any other appliwble ordinances of the Ciy. (2) This permR ghail expire if (A) the work authorized is not coinmenceC wRhin aiMy (60) tlays trom iesve tlate or (B) the building aWhonzed is suspandeE or abandoned for a periotl of 120 days. (3) If this pertnlt expires, a new permit may be acquired Por a fee ol one-half the amount nortnally requiretl, provided no changes have been or will be mede in the original plans and spedfieaBOns aM any suspension or abanCOnment has not exceMed one (t) year. If changes are made or H suspemWn or abandonmenl exceeda one (1) year. NII feee shall be paiC kr a new permit , (4) No vrork ot arry manner shall be done Mat wlll Uwnge the nalural flow of water pusing a d2lnage problem. (5) ConUactor ahall notiy the Buiiding Inspeclor tweny-(our (24) hours in advance for ell inspectlana antl shall reteiva written appmval on Inapection oeM befora prooeediing with successive phases of the ob. (8) The issuance of a peimit or Me epproval o~drawinps anA sperlfiptlons shall not be mnsWed to Oe a peimit tor, nor an approval ot arry vblation of the Drovislona of the building todes or any otlier oidinance, law, rule or regulaGOn. Chief Building inspector 0~)'