HomeMy WebLinkAbout5650 W. 36th Placei CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection -Type: _ '-
Job Address:
Permit Number: 0
a
❑ No one available for inspection0.Time .- .
`. AM/PM
Re -Inspection required: Yes Io3
When corrections have been made, schedule for re -inspection online at:
h ttp://www. ci. wheatridge. co. usrnspection
Date:-/ t1 ' uaG Inspector: 3.
DO NOT REMOVE THIS NOTICE
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION
City of Wheat Ridge
E -Res. A/C Replacement PERMIT - 202001345
202001345 ISSUED: 07/20/2020
5650 W 36th P1 EXPIRES: 07/20/2021
Replacing 2 ton, 13 seer A/C in backyard.
*** CONTACTS ***
OWNER (218)269-7466 HAAS JOHN
SUB (303)407-7967 STEPHEN LANYON
017835 BLUE SKY PLUMBING
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,116.46
FEES
A/C Replacement 60.00
Total Valuation 0.00
Use Tax 86.45
** TOTAL ** 146.45
*** COMMENTS ***
*** CONDITIONS ***
Both the front and back of this permit are required to be posted on the job site at all
times. If the complete permit is not present, inspections WILL NOT be performed.
Work shall comply with 2012 IRC & 2017 NEC. Smoke alarms shall comply with 2012 IRC Section
134. INTERIOR ALTERATIONS, REPAIRS, FUEL -FIRED APPLIANCE REPLACEMENTS, OR ADDITIONS, ANY OF
WHICH REQUIRE A BUILDING PERMIT, OCCURS OR WHERE ONE OR MORE ROOMS LAWFULLY USED FOR
SLEEPING PURPOSES ARE ADDED SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED
WITHIN FIFTEEN FEET OF THE ENTRANCE TO EACH ROOM LAWFULLY USED FOR SLEEPING PURPOSES
11* 4 City of Wheat Ridge
E -Res. A/C Replacement PERMIT - 202001345
PERMIT NO: 202001345 ISSUED: 07/20/2020
JOB ADDRESS: 5650 W 36th P1 EXPIRES: 07/20/2021
JOB DESCRIPTION: Replacing 2 ton, 13 seer A/C in backyard.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications;
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the roperty and am authorized to obtain this permit and perform the work described and approved in conjunction with
this ppermit. I further attes that I am leggally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be pertbrmed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4, No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall n t proceed or conceal work without written approval of such work from the Building and Inspection Services
Divas
6. The ss nce r grant . of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
ap lee e or a d' ance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
C�ty o� Whoat HidgoCI
v,/ZU/202O O8�2U CD8B
Ce»lac�nD 2 �nn. 13
'08U23235
' HMGUNT
yp�� 565O W 36th Pl 146.45
PAYMENl KECElV[D AMOUNT
pp / 3Y1O
146.45
AU7H CODE: Y832514�
TOTAL
146.45
Dina Kemp
From:
no -reply@ ci.wheatridge.co.us
Sent:
Friday, July 17, 2020 11:17 AM
To:
CommDev Permits
Subject:
Online Form Submittal: Air Conditioner/Evaporative Cooler Permit Application
Categories: Dina
Air Conditioner/Evaporative Cooler Permit Application
This application is exclusively for AIR CONDITIONER OR EVAPORATIVE
COOLER.
YOU MUST ATTACH THE ELECTRONIC PAYMENT FORM IN ORDER FOR THE
PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
PROPERTY INFORMATION
Is this a new install or
replacement for an
existing AC unit?
Property Address
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
Property Owner Email
Address
Attach City of Wheat
Ridge Electronic Payment
Form - **DO NOT
ATTACH A PICTURE
OF A CREDIT CARD**
Replacement of Existing Unit
5650 W 36th Place
John Haas
(218) 269-7466
oldmanhaas@gmail.com
scan0004.Pdf
CONTRACTOR INFORMATION
Contractor Business Blue Sky Plumbing & Heating
Name
I
Contractor's License 017835
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone 303-407-7967
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Email Address randyp@blueskyplumbing.com
Retype Contractor Email randyp@blueskyplumbing.com
Address
DESCRIPTION OF WORK
What type of replacement Air Conditioner
unit are you installing?
How many tons is the 2
unit?
For AC - what is the 13
SEER?
For Evaporative Coolers,
what is the CFMs?
Where is the unit located backyard
(for example, rooftop,
backyard on ground etc)?
Is electrical needed for re- Yes
hook?
Provide Electrical 017835
Contractor's Wheat Ridge
License No.
Project Value (contract 4116.46
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
2
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Person Applying for Jesse Lanyon
Permit
Email not displaying correctly? View it in your browser.
City of Wheat Ridge
Residential Roofing PERMIT - 201709172
PERMIT NO: 201709172 ISSUED: 11/21/2017
JOB ADDRESS: 5650 W 36th PL EXPIRES: 11/21/2018
JOB DESCRIPTION: Re -deck and Re -roof; remove and replace laminated shingles and replace with
modified bitumen in Heather Blend; 6.79 sq of rolled material. Flat and
15.12 of pitched. Total sqs 21.91
*** CONTACTS ***
OWNER (218)269-7466 HAAS JOHN & GILLIAN
SUB (303)750-4295 Seth Curry 170393 4th Dimension Concepts
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,764.00
FEES
Total Valuation 0.00
Use Tax 184.04
Permit Fee 188.45
Investigative Fees 188.45
** TOTAL ** 560.94
*** COMMENTS ***
*** CONDITIONS ***
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required for both the midroof and final inspections. The 3rd party inspection report AND
THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat
Ridge. The report MUST BE SIGNED by the Homeowner.
REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec.
R806. The installation of ridge venting requires the installation or existence of soffit
venting. For calculation purposes, one hat or turtle vent equal to one-half of one square
foot of opening.
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name) roof
covering" is required to be on site at the time of final inspection.
City of Wheat Ridge
Residential Roofing PERMIT - 201709172
PERMIT NO: 201709172 ISSUED: 11/21/2017
JOB ADDRESS: 5650 W 36th PL EXPIRES: 11/21/2018
JOB DESCRIPTION: Re -deck and Re -roof; remove and replace laminated shingles and replace with
modified bitumen in Heather Blend; 6.79 sq of rolled material. Flat and
15.12 of pitched. Total sqs 21.91
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that [ am the legal owner or have been authorzed
by the legal owner of the property and am authorized to obtain this ermit and perform the work described and approved in conjunction with
this permit. I further attest that I am_.l.eggally authorized to includealentities named within this document as parties to the work to be
performed and that all wor be pert is disclosed jn this document and/or its' accompanying approved plans and specifications.
�W
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Bui?ding
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official'mate
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Kimberly Cook
a 0 l�
From: no-reply@ci.wheatridge.co.us
Sent: Monday, November 20, 2017 9:40 AM
To: CommDev Permits
Subject: Online Form Submittal: Residential Roofing Permit Application
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person r
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
Property Owner Email
Address
5650 West 36th Place
John and Gillian Haas
2182697466
oldmanhaas@gmail.com
49
Do you have a signed Yes
contract to reroof this
property?
Applications cannot be
submitted without an
executed contract
attached below.
Attach Copy of Executed haas contract.pdf
Contract
CONTRACTOR INFORMATION
Contractor Business
Name
Contractor's License
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Address
(Primary address of your
business)
4th Dimension Concept
170393
7206970232
1300 S Potomac ST Aurora CO 80012
Contractor Email Address jcontreras@4thdc.com
Retype Contractor Email jcontreras@4thdc.com
Address
DESCRIPTION OF WORK
TOTAL SQUARES of 21.91 _
the entire scope of work:
Prdjec# Value (contract $8764
value<or cost of ALL
materials and labor)
Are you re -decking the
roof?
Is the permit for a flat
roof, pitched roof, or
both? (check all that
apply)
Yes
Flat roof (less than 2:12 pitch)
2
What is the pitch of the
1/12 and 2/12
FLAT roof?
How many squares are
6.79
part of the FLAT roof?
Describe the roofing
modified bitumen in Heather Blend
material for the FLAT
roof:
Type of material for the
Rolled
FLAT roof:
Provide any additional
remove and replace laminated shigles
detail here on the
description of work. (Is
this for a house or
garage? Etc)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
3
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Name of Applicant Seth Curry
Email not displaying correctly? View it in your browser.
RA;+
Tully Insured
License €# 891841
1730 S Abilene St. Suite 204
Aurora, CO 50012
Phone: (303) 750.4295
Fax: (3 03) 49-5.5111
office in fo@4thde.com
w14 %%' _thdcxozn
Owner(s) Phone 4(s) C A647'�TXJW3 ?IL
Project Manager Email CLZRMW�s @ kL-L'C694
Address 565b City State co Zip sba'la'
Ihve, the owners of the described premise below, hereafter referred to as buyer, offer to contract with 0
Dimension Concepts, LLC, (Authorized Contractor), and hereafter referred to as seller, to furnish, deliver,
and arrange for installation all material necessary to complete the improvement at the premise:
INSTALLATION LOCATION: Street
City_
State Zip
AGREEMENT SPECIFICATIONS: approved materia] rill be rnished and in tail ed accordingly.
-� Y� b a- :s. a--� . VVk?, lug
�t d` +air ,• E his t` �;• ' `,/v`r-- /3/
1~yr�s h,'� • ��:�:� `M _ �_'� �.� '.;%� 7 /�.1 Ott.. ILI i .i f •
All warranties are provided thru 41" Dimension Concepts, LLC, including a five (5) year workmanship
warranty.
Note: reverse side ofagreem nt m include site preparation required by Owner.
Appro it tUt Dai Approximate Completion Date �S ` � . t
Total Cost & Deposit Completion Balance $ QIZYAGR� 0.1
Owners do jointly and severally, PROMISE TO PAY UPON COMPLETION OF IMPROVEMENTS,
payment made to 4'" Dimension Concepts, LLC, and given to their agent / foreman. Any failure or
unauthorized change by owner(s) may incur additional fees and cost of collection. Verbal understlidings.
and agreements with representatives shall not be binding. Additional documents may support t b
IV
description and related improvement. Additional provisions on reverse side of agreement_ CJS
Note: Door to Door sales Ilow for three day cancellation — see reverse for instructions. t
All checks made ayl 0 411' tnension Concepts, LLC 2O� Pc►
Accepted BDate -� �'��� t•
Approved y �`-� Date 5' LL 17 CaKIM SX S
lfcc
Certificate of Completion
AND/OR
Compliance
CITY OF WHEAT RIDGE
7500 W. 29TH AVENUE
WHEAT RIDGE, COLORADO 80033
THIS CERTIFICATE VERIFIES THAT THE PROPERTY DESCRIBED BELOW, DOES
COMPLY WITH THE WHEAT RIDGE BUILDING CODE, ZONING AND OTHER
RELATED LAND USE AND DEVELOPMENT LAW S OF THE CITY OF WHEAT RIDGE
FOR THE FOLLOWING PURPOSE.
PERMIT # 16222
Patio Cover
OWNER: Regina Kole ADDRESS: 5650 W. 36"' Place
PROPERTY ADDRESS: 5650 W 36"' Place Wheat Ridge, CO 80033
CONTRACTOR: Douglas Construction
DATE 9/24/2003 CHIEF BUILDING
ZONING ADMIINIS'
~ W
~
Cl)
~ w ~
zZ
o
W J
Q m
~W
mx
F-
00
iz
~
w
,-i N
~ O
cn a
Z N
O Q
P:
w ~
a
a U
CQ U)
Z =
F-
Cl)
Z
0
W
a
z
0
U.
~
Q
I.LU
0
z
C/)
cc
2
N
0
0
a
~
0
J
O
(0)
M
CW)
~
~
a
~
a_
M
N
Q~
o
~
M
C)
N
~
a
C
M
~
O
~
V
W
M
W%
Z
W
0
0
w
,
\
~
a
W
>
W
W
N
a
~
~
C/)
~
W
Z
~
~
~
w
0
w
~
~
~
~
0
~
0
~
¢
0
~
Z
J
O-
~
°
CD
~
O
~
Y
O
Ln
p
~
a
G7
Z Q
° z
¢
Q
z
U
m
~
0
I
m O
0 ~
vwi
m
0
~
m
W
o
~
-
_
~
0
Z
~
z
I
a
~
W
0-
U)
M
~
a
p
cf)
J
Q
~
z
0
~
~
p
~
~
0
a
z
O
U)
U
z
U
-
~
w
a
c°
Z
_
y
c
~
0
O
C,
O
m
-0
N
~
c
~
C
~
O
L
0
N
C
(
~
U
~
i
t
3:
0
W
z
LD
Cl)
z
w
W
m
CO
¢
_
W
>
0
m
Q
~
z
Z)
W
w
~
U
z
0
0
z
~
~
0
0-
~
ooY
LL ~ ~ ~
c-ad
u) 2 2 _
d ~
d ~ m
C
W n_ _
M
a
~
0
~
0
~
m
>
o
s
~
m
~
w
L
o~
0
m
~
~
a
L
m
0
Q
~
ctl
~
~
F
~
Q
~23
m
N
=
L
m
o
CC
,
C
E
co
LL
o
~
~
y
S
o~
?
t6
3
a
~
m
C
'o
o
~
O
ro
~
a~
~
0>
~
=
m
~
~
a~
W
~
~
L-
m
i
~
a)
W
'
.p
E
0
d
m
~
>
06
m
C
m
~
2
N
E
m
Ll
m
.ro
Q
~
~
O
c~
~
~
o_
IL)
LL
-
u~i
ro
J
°tf
C~
Y
ro
a.
i
.
~
~
"
LL
~
0
1
LLI
a
;
U
;
LL
W
Q
'
J
W
W
'
i
Z
N
~
;
o
W
~
N
Z
0
cc
tL
°
;
;
i
w
a
~
U
=
t-
0
Z
Q
0
U
ul
U
~
a
z
a
M
O
I
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING INSPECTION LINE - (303-234-5933)
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80033 - (303-235-2855)
Building Permit Number
Date
16222
9/16/2003
Property Owner: REGINA KOLE
Property Address : 5650 W 36TH PL
Contractor License No. : 21762
Company: DOUGLASCONSTRUCTION
Phone :
Phone : 995-9455
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and
do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibi' Feewo' the Wheat Ridge Building Code (U.B.C J and all other applicab ' geg~~inances, for wo under lhis permit.
(OWNER)(CONTRACTOR NE ~ - TE
Construction Value :
$3,000.00
Permit Fee :
$108.30
Plan Review Fee :
$0.00
Use Tax :
$36.00
Total:
$144.30
Use:
Description : PATIO COVER - RMOVE EXISTING PATIO COVER AND REPLACE WITH NEW.
BUILDING DEPARTMENT USE ONLY
Z o 19 SIC : Sq. Ft. :
Approval : MA 9/11/03
Zoning: R-1C
Approval: DM
OK PER ROOF PITCH REDLINES. 9/16I03
Approval :
Occupancy : Walls : Roof : Stories : Residential Units :
Electrical License No : Plumbing License No : Mechanical License No :
Company: Company: Company:
Expiration Date : Expiration Date : Expiration Date :
Approval : Approval : Approval :
(1) This permit was issued in accordance with the provisions set foM1h in yopur application and is subjec[ to the laws of the State o( Colorado and to the Zoning
Regulations and Building Code of Wheat Ridge, Coloredo or any other applicable ordinances of the City.
(2) This permit shall expire if (A) the work authorized is not commenced within sixry (60) days trom issue date or (B) the building authorized is suspended or
abandoned for a penod of 120 days (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in ihe
original plans and specifcations and any suspension or abandonmenthas not exceeded one (7) year. If changes are made or if suspension or abandonment
exceeds one (1) year, futl fees shall be paid for a new pertnit.
(4) No work of any manner shall be done that will change the natural Flow of water causing a dreinage problem.
(5) Contractor shall notifythe Building Inspector lwenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before
proceediing with successive phases of thejob. .
(6) . The issuance of a pertnit or the approval of drawings and specifcations shall not be construed to be a permit for, nor an approval of, any violation of the
prov„ on, of th buil i g codes or any other ordinance, law, rule or regulation. . .
ar
Y~°4 S
ie{Building spector
Please sign Terms and Conditions on reverse side of page.
oF w~EqT COMMiJNITY DEVELOPMENT DEPARTMENT Building Pemvt Number. /
; P BUILDING INSPECTION LINE - 303-234-5933 Date:
° CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE ~
WHEAT RIDGE, CO 80033 -(30g3y-235-2,5~5i5//)5~~~7/ /
coCORPD~ 1/~3"PL~{o134IV 4Y ~
Property Owner: R2colrkl, x0 lc
Property Address: S b$'O (-0 Phone :
Contractor License No.: p? (L,~
CompanY:-Po., 5 ~a N~.~ Phone: .~01 9%S 7
~41
O\tlnER/CONTRACIOR SIGNATURE OF UNDERSTANDING AND ACREEMENP
I hereby certify that Ihe setback distances proposed by [his pertnit application are accurate,
and do not viola[e applicable ordinances, nles or regula[ions of [he City of Whea[ Ridge or
covenants, easements orrestnctions of record; that all measuremen[s shown, and allega[ions
made are aceunte; that lhave read and agree ro abide by all conditions pnn[ed on this
appiication and that I assume full res iry for compliance with the V✓heat Ridge
Building Code (U.B.C) and all oth applicab V✓heat Ridge Ordinances, for work under
[hispermit ` . `
(OWNER)(CONTRACIOR):
(ONTER)(CONTRACfOA):
Construction Value:$ 3.e0e'
Permit Fee:$
Plan Review Fee:$
Use Taac:$
Total:$
DESCRIPTION:
Pj-io Qpvcr -
Rey~aL ze.r
Al~l
BUILDING DEPARTMENT USE ONLY
SIC: S~C~q.Ff~~O~j
ZONING COMMEN75:
Approval:
G3
Zoning:
BUILDINGCOMMENTS:
Approval:
PUBLIC WORKS COMMEMS:
Approval:
Occupancy:
Walls RooL
Stories:
Residenrial Uniu:
Electrical License No: Plumbing License No: Mechanical License No:
Company: Company: Company:
Expiration Date: Expirarion Date: Expirarion Date:
Approval: Approval: Approval:
(1) This pemiii x•as issued in accordance wi11i the provisions set forth in your appiication and is subject to iM1e laws of the State of Coloado and a the Zoning
Regularions and Buiiding Cades of Wheat Ridge, Coloado or any othn applicable ordinances of [he Ciry.
(2) 77iisyermitshallexpireif(A)theworkauthorized'anotcommrncedwithinsixry(60)daysfromissuedareor(B)IhebuildingauNorizedissuspendedor
abandoned for a period of 120 days.
(3) If this pemiit expires, a tiew pemiil may be acquired for a fte of one-lialt tlie amount nomially required, prarided no changes hare been or will be made
in Ifie original plans and specificarions and any susprnnion or abandonmrnl hu mt exceeded oce (1) year. If changes have been or if suspension or
abandonment ex¢eds one (1) year, fu0 fees shall be paid for a new permic
(4) No work of any manner shall be done that will change Ihe naNral Flow of water <ausing a drzinage problem.
(5) Contracror shall notlfy ihe Building ]nspecror twenry-iour (24) hours in advance Cor all inspections and shall receive wntten approval on inspection card
before proceeding with successive yhaxs oCthejob.
(6) The iuuance of a permit or die approval of dawing and specificaUOns shall not be conswed a be a permit for, nor an approval of, any violation of the
provisions of the building codes or any bther ordinance, law, rule or regulatlon.
/ /
.r7~~
~ildingnypector
V
Colorado Chapter
International
Provide two sets of plans and complete the following:
1 Complete this Building Guide by fiiling in the blanks on page two, and indicating
which construction details will be used. -
2 Provide 2 Plot Plans (site plan) showing dimensions of your project or addition
and its relationship to existing buildings or structures on the property and the distance
to existing property lines drawn to scale.
3 Fill out a building permit application.
The majority of permit
applications are processed
with little delay. The
submitted documents will
help determine if the
project is in compliance
with buildirig safety codes,
zoning ordinances and
other applicable laws.
The Colorado Chapter of the international
Code Council is a professional
organization seeking to promote the public
health, safery' and welfare to building
construcbon. We appreciate your feedbadc
and suggestions. To obtain a master copy
of this buildin_g guide, please write to the
Cdorado Chapter of the intemational Code
Council, P.O. Box 967, Arvada, CO 80001.
This handout was developed by the Colorado
Chapter of the International Code Council as a
basic plan submittal under the 2000 International
Residential Code. It is not intended to cover all
circumstances. Check with your Department of
Building Safety for additional requirements.
Citv o{`Wheat 4~ge
BuilQing ~Division
75007N 29'fiAve.
Wheat 9Z,uCge, CO 80033
(303) 235-2855
~OF WHESj
~ P
o
V
~~CORPDO
' 1 l
How to Use this Guide
wi Wue m
~ , Family 1 . d. al Pa , ( . , Carports
•
DirecUons
1. Fill in the blanks with d'unensions and materials which
will be used to build the structure. Please print legibly.
2. Indicate in the check boxes which details from page 3 will be used. Please note if any of the sides of your
carport addirion aze doser than 3'-0" to the property line, that side of the carport must be enclosed with a
solid 1 hour fire rated wall as shown in Altemate Details B and C. You must however, keep at least two sides
of the carport open to conform to the building code requirements. Zoning approval is required.
3. Roofing to be installed per manufacturer's instructions, including low slope application and required inspections
made.
Roof coverin C/ka 42 Underlayment ~ LQVUs /S~~1F
(exemple: Class A 31ab shingl ~ (e~mpl : 2layers 75Rlett)
Sheathing S"/R "CDr
12 ~ample: i!2'extenor IywooE)
pitch ~ m
2x-& rafters spaced 14 " O.C.
(erample: 2 x B ieRers spscetl2d'O.C.)
atio Sectio
u., Overhang
No closer than 2
TM feet to property line
- Beam splices to occur
•4' , over posts with 1 1/2
, bearing
liamitilit, ❑ DeWll A Detail B
Alternate A ❑ Alternate B X ~D ~~beam
P89a3) «~~3) (example:(2)7x10'J
Existing
building Spair--25~'
Maximum ~ • (e,wnoe: 12-0'J
rise 8" Detall G
at door ~ Altemate C
r~page 3) --8° Siding
IsolatefromSlabminimum (twAlfemffie9onlyJ
Slope
x-~D( "posts
,
(a'wwe:e•x<•)
Concrete Siab 3'-0° spaced ~apart
minimum
Minimum Diameter Pier 8" Footin
x
gfa„emteC «,~y~
This handout was developed by the Colorado Chapter of the
International Code Councii as a basic plan submittal under the 2000 Internatbnal Residential Code. It is not intended
io cover ali circumsiances. Chedc with your Departrnent of
Building Safery tor addi6onal requirements.
2
~
Existing roof rafters or tmsses
Galvanized metal joist or ra8er hangers
~ Ex~end undedayment from
new roof a minimum of 18'
onto exsting roaf
Lap underlayment a minimum of 18' under existing roofing felts
Solid 2~c blocking-- Roof tie downs required
' ~ Remove existing tascia Exis6ng
Cont. 2- ledger wall
Secure ledger to wall wilh 4'/z' x 3/8' min. lag bolts @ ~
16' O.C. Locate lag bolLS to penetrate top plate or studs ,
Note: Remove bridc veneer at rop of wall
wall before installing contlnuous 2u ledger
Solid 2x blocking Roof tie downs required Solid 2x fire blocking 2x facia
tie downs required
Galvanized metal
post/beam connector
518' type'X' exterior
gypsum sheathing
Galvanized metal
posUbeam connector _
Exterior siding -
Infill between posts wl
2x4's @ 16' O.C.
Existing Roof
Cont. 2x6 secured to existing roof with
fasteners af each rafter or truss
No doser than 2 feet
to property line
518'rype "X" exterior
gypsum board soffit
Treated or decay Bottom plate shail be treated Infill between posts
resistive post wood or Foundation redwood w/ 2x4's @ 16" O.C.
Minimum 3 1/2" Galvanized Minimum 3 1/2"
concrete siab cotumn base w/ concrete slab 2~ Galvanized column
t" spacer to base w/ 1" spacer
to concrete
Isolate Isolate ~
from Slab Anchor bolt from Slab ~i~~ i, Anchor bolt
`;•~:uF~ 7" minimum k= • 7" minimum
enetration Check local ! c
8" minimum 3'-0" P penetration
diameter minimum building 3'-0"
concrete departmentfor minimum
swelling soils. :'',.:;:r•
caisson
caissons may
~f
be required. - Footin
9
SH~
This handout was developed by the Colorado Chapter of the
International Code Council as a basic plan submittai under
the 2000 International Residential Code. Ii is not intended
to cover all circumshances. Gheck with your Department ot
Building SafeTy for additional requirements.