Loading...
HomeMy WebLinkAbout7060 W. 32nd Place11&(5i 32-2' t City of Wheat Ridge Residential Roofing PERMIT - 201801500 PERMIT NO: 201801500 ISSUED: 05/23/2018 JOB ADDRESS: 7060 W 32nd PL EXPIRES: 05/23/2019 JOB DESCRIPTION: Reroof remove and install 901b Rolled Roofing System and GAF Timberline Asphalt Shingles with 24 total squares, 21squares pitched and 3 squares flat. Pitch .5/12, 4/12. House and Detached Patio Cover. * * * CON'T'ACTS OWNER (303)233-5146 COOLEY DAVID L SUB (720)331-1803 Doug Gray 170234 Strait Line Roofing Services *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: OA// Unassigned *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,850.00 FEES Total Valuation 0.00 Use Tax 206.85 Permit Fee 204.30 ** TOTAL ** 411.15 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. i-7�� C�� • 5�2 �i `��� Z PERMIT• 1 �I DO ADDRESS: 1'��6a�/yiI JOBCODE: Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler/ urnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 401 Gasline 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial X407 Final Plumbing Residential 408 Final Plumbing Commerciai 409 Final Roof 1 410 Final Window/Door 411 Land scape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. INSPECTION RECORD 05/!2- ) y/' 2 Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day PERMIT: ( ADDRESS: �i°V T , JOB C DF,: Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation _ Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. _ 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS The City of Wheat Ridge Third Party Form Check List Property Address Permit Number Permit Issued Date Owner Information Property Owner Information Property Owner Address Inspector Information Inspection Company Inspector Name Inspector Contact info. �c cel �c ------------- Lc,4_P__' GSL 76p0 &&o 9's=l -7 Inspector Statement and Acknowledgement * I hearty acknowledge the roof 1 am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * i hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's Inspector: Date: 6 — % /� Property Owner Statement of Acknowledaement *1 hearby acknowledge that i am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat �RlideBuil 'n ivisi !,inspection. Propery Owner/Agent: Date:— /x This original document and permit card, as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W. 29th Ave Wheat Ridge CO 80033 Draft Date: 7/26/17 Please add note to reverse side Roof Inspection ❑ N/A ❑ Pass ❑ Fail ❑ N/A ( Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A aPass ❑ Fail ❑ Pass ❑ Fail aN/A JN/A ❑ NIA ❑ N/A ❑ N/A ❑� N/A [: N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A N/A N/A N/A N/A N/A NIA i N/A ❑ Pass ❑ Fail ❑ Pas ❑ Fail Pass ❑ Fail 2 --Pass ❑ Fail i Pass ❑ Fail 9 Pass ❑ Fail ❑ Pass ❑ Fail Pass ❑ Fail Pass ❑ Fail [} Pass ❑ Fail Pass ❑ Fail O Pass ❑ Fail ,'Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail The City of Wheat Ridge Inspection Check List notes Mid -Roof Structural roof components Verify that no more than 2 layers of shingles exist Flashing for roof and walls If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Verify sheathing nail pattens (See Policy ,& Procedures) Crickets and saddles where needed Verify B vent must have boot same gauge as pipe Verify vent caps Verify no flashings are damaged or rusted Step flashing shall be min. of 4x4 piece per shingle Verify scuppers allow for proper drainage Ice and water shield 2' in heated wall spaces Underlayments must follow 2012 IRC 12012 IBC Verify roof slope for proper drainage Dripedge shall have min of 2" overlap Dripedge should extend down min 2" past roof deck Dripedge shall be mechanicaly fastened 92" OC 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 Modified Bitumen, EPDM, TPO min slope 1/4:12 slope Above roof insulation R-25 Below roof residential R-38 Below roof commercial R-32 Modified Bitumen, EPDM, TPO min slope 9/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with theaddres Metal R©of Reguiremenis s on the letter for final inspection Shingles ❑ Pass ❑ Fail Metal roof shingles shall not be installed on ziope legs 3:92 ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow fine with sections overlapping a a min. of 4" "file Roofs Requirements ❑ Pass ❑ Fail Clay and concrete file shall have a min. 2-1/2:12 slope Slopes 4:92 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Mid -Roof Notes 6 ✓t t- C--& t,-7 1- r a Company Name: -- � � .' Z_L (- Inspector signature: Date of Inspection: - 7 --r The City of Wheat Ridge Inspection Check List notes Final Roof Roof Inspection ❑ N/A ❑ Pass ❑ Fail ❑ N/A aPass ❑ Fail Structural roof components ❑ N/A {Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A 'Pass ❑ Fail Flashing for roof and wails 1i ❑ Pass ❑ Fail If new sheathing is installed verify that it is listed in the []!-N/A ❑ Pass ❑ permit description (Valuation must be adjusted) Fail Verify sheathing nail pattern (See Policy & Procedures) [ N/A ❑ Pass ❑ Fail Crickets and saddles where needed ❑ N/A Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A [ Pass ❑ Fail Verify vent caps ❑ N/A Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle N/A ❑ Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A [ Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A (Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A E4 Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC N/A ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope; Exception: detached garages, patios, carports, open on three sides with min. slope of 1:12 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope N/A ❑ Pass ❑ Fail Above roof insulation R-25 N/A ❑ Pass ❑ Fail Below roof residential R-38 N/A ❑ Pass ❑ Fail Below roof commercial R-32 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturer's specifications - Must have manufacturer's letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2- slope Slopes 4:12 and under require double underlayment 0 MO Company Name: Inspector signature: Date of inspection: The City of Wheat Ridge Inspection Check List notes Final Roof Notes q 4 <41 City of Wheat Ridge Residential Roofing PERMIT - 201801500 PERMIT NO: 201801500 ISSUED: 05/23/2018 JOB ADDRESS: 7060 W 32nd PL EXPIRES: 05/23/2019 JOB DESCRIPTION: Reroof remove and install 901b Rolled Roofing System and GAF Timberline Asphalt Shingles with 24 total squares, 21squares pitched and 3 squares flat. Pitch .5/12, 4/12. House and Detached Patio Cover. *** CONTACTS *** OWNER (303)233-5146 COOLEY DAVID L SUB (720)331-1803 Doug Gray 170234 Strait Line Roofing Services *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,850.00 FEES Total Valuation 0.00 Use Tax 206.85 Permit Fee 204.30 ** TOTAL ** 411.15 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201801500 PERMIT NO: 201801500 ISSUED: 05/23/2018 JOB ADDRESS: 7060 W 32nd PLS EXPIRES: 05/23/2019 JOB DESCRIPTION. Reroof remove and install 901b Rolled Roofing System and GAF Timberline Asphalt Shingles with 24 total squares, 21squares pitched and 3 squares flat. Pitch .5112, 4/12. House and Detached Patio Cover. 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am t e legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attesf that am le filly authorized to include al I entities named within this document as parties to the work to be performed and that all work to be perfgn ed is disclosed in this document andlor its' accompanying approved plans and specifications. Signature of OWNERor /CONTkXftOR (Circle one) Date I, This permit was issued based on the'information provided in the permit application and accompanying Flans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3, If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6� The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinalije or regulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of Chief BuiAng Official Date REQUESTS MUST BE MADE BY 11959PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. La enia Reimer From: no-reply@ci.wheatridge.co.us Sent: Wednesday, May 23, 2018 11:22 AM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) 7060 w 32nd pl Cooley 303-233-5146 Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. dgray65@gmail.com Yes Attach Copy of Executed 77154142-7508-498E-B1AF-2316C99EE019.ipeg Contract CONTRACTOR INFORMATION Contractor Business Strait Line Roofing Name Contractor's License 170234 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) 720-331-1803 8871 so. carr ct. Contractor Email Address dgray65@gmail.com Retype Contractor Email dgray65@gmail.com Address DESCRIPTION OF WO TOTAL SQUARES of 1 24 the entire scope of work: Project Value (contract 1 9850 value or cost of ALL materials and labor) Are you re -decking the No roof? ; Is the permit for a flat lat;tt,?pt (less than 2:12 pitch), Pitched roof (2:12 pitch or roof, pitched roof, or g ) 0) both? (check all that apply) What is the pitch of the .5 FLAT roof? How many squares are 3 part of the FLAT roof? Describe the roofing 90 Ib roll material for the FLAT roof: Type of material for the Rolled FLAT roof: What is the specific pitch 4/12 of the PITCHED roof? How many squares are �2d part of the PITCHED roof? Describe the roofing GAF timberline materials for the PITCHED roof: Type of material for the Asphalt PITCHED roof: Provide any additional House and detached patio cover detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will 3 be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Doug Gray Email not displaying correctly? View it in your browser. INSPECTION RECORD Occupancy/Type ® INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) y Heating (Underground) plec S ng all tie f l Service tric WOVE HAS BEEN SIGNED - DO NOT P OUR FLOOR UNTIL ABOVE HAS BEEN SIGNED rcouyn rwrnDing Gas Piping _ Rough Mechanical - ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING Framing Insulation Drywall Screw ' FINALS Electrical COMMENTS: Footings /Caissons - Plumbing - - Stemwall / (CEG) Concrete Encased Ground Mechanical Reinforcing or Monolithic. Roof 111 � L .. `D..:. Weatherproof / French Drain Building Final .Sewer Service tines Fire Department ti I R.O.W & Drainage - INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUB _ICE WORKS SHOULD BE CALLED AT. LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS..' Parking & Landscaping 'NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE RUTH( OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS IF' DO�/ YELP F n �, rri RA T1 I IAI .A Ti FOUNDATION INSPECTIONS. DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons - - - - Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic. Weatherproof / French Drain .Sewer Service tines Water Service Lines - ♦ i CITY OF WHEAT RIDGE' f Building Inspection Division / (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: Aw-1 Wit= Job Address: Permit Number: A hak/ ,�'9 ❑ No one available for inspection: Time f PM Re- inspection required: Yes No * When corrections have been made, call for re inspection at 303 Date: ?�/D Inspector: &L DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-59331nspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: kw Job Address Permit Number: Ct d ra 1 f t No one available for inspection: Time Ea &PM Re-Inspection required< No When corrections have been made, call for re-inspection at 303-2345933 Date: Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTIO NOTICE Inspection Type: Job Address: Permit Number: C?°i~¢ j S 1 P, No one available for Inspection: Time (,'0 {7 A'.'~ Re-Inspection required: es No *When corrections have been made, call fort e-inspection at 303-234-5933 Date: L 9 )i(1 Inspector: I . DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division r (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTIQ,N Inspection Type: l Job Address: 1)060 4.1.) z~Q Permit Number: ❑ No one available for inspection: Time M Re-Inspection required:.. Ye No ' When corrections have been made, call for re-inspection at 303-234-5933 a Date: 5"I w Inspector: is a DO NOT REMOVE THIS NOTICE 44' City of Wheat Ridge' O: ESS.......: I oFW"~Tg City of Wheat Ridge Building Division m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Date: Office: 303-235-2855 ~ Fax: 303-235-2857 Plan °OCORno° Inspection Line: 303-234-5933 X15/ Permit Building Permit Application Property Address: ~60 U/. Sand Ave Property Owner (please print) ~ Cnntey Phone 303-233-51yl0 Mailing Address: (if different than property address) Address: 7066 e/ Q✓fl _a A_ p City, State, Zip: IA/ f i tl C~ P 1n /50031 Contractor: Contractor License 09,0</- (05 Phone: 3o3 - V63-5451 Sub Contractors: Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): T=a' Q "10C-e_ Construction Value: $ Description of Work: (as calculated per the Building Valuation Data sheet) Plan Review (due at time ofsubmittan: $ Sq. Ft./L.Ftadded: . - Squares2_BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by allegations this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and gations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit: Plans subject to field inspection. CIRLCE ONE:: (OWNER). (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR) PRINTNAME SIGNATURE: Date: BUILDING DEPARTMENT COMMENTS: Reviewer. FIRE DEPARTMENT:: ❑ approved w/ comments ❑ disapproved ❑ no review required OCCUPANCY: Bldg Valuation: DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : COOLEY TALLEY J Property Address : 7060 32ND PL Contractor License No. : 17747 Company : Dick's Custom Roofing OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable pe(heat Ri ge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED ~1~ ~Se~ oarEz^3`~S/ Description : REROOF Building Permit Number : 95-256 Date :2/3/95 Phone : 233-5146 Phone : 989 6833 ConstructionValue: $1,168.00 Permit Fee : $41.00 Use Tax : $17.52 Total: $58.52 Electrical License No : Company : Plumbing License No : Company : Mechanical License No : Company : Expiration Date : Approval : Expiration Date : Approval: Expiration Date : Approval: m { om Im LONEl., ES a (1) This permit was issued in accordance with the provisions set forih in yopur application and is sub'ec[ [o the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Coloretlo or any other applicable ortlinances of t~e City. (2) This permit shall expire if (A) the work au[horized is not commencetl within sixty (60) days from issue date or (B) ihe building auihorized is suspended or abandoned for a period of 120 tlays. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been orwill be made in the original plans and specifications and any suspension or abandonment has not exceeded one (7) year. If changes are made or if suspension or abandonment exceetls one (1) year, full fees shall be paid for a new permit (4) No work of any manner shall be done ihat will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspec[or twenty-four (24) hours in advance for all inspecUOns and shall receive written approval on inspection card before proceediing with successive phases of thejob. - (6) The issuance of a permit or the approval of d2win95 antl specifcations shall not be consWed to be a permit for, nor an approval of, any violation of the provisions of the builtling co~ r apy olher ordinance, law, rule or tegula6on. c,c~ I c-t Chief Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 Date: Z-3- CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 PropertyOwner: IP~ue~( J-CDOI.tiy ~ z 3 Property Address : -70 &O 0 .3'9114 p P L Phone: 3 -51 q G . Contractor License No. : 1'7 '7 q7 Company : O1LK"S (20 sTOw1 PpOFt,~t 5 Phone : 9g °t -&8 33 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this pertnit application are accurete, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.CJ and all other applicable heat Ri~ ge ordinances, for work under this permit. ~ -3 e~ Construction Value : I i 1 (11 g°_° Permit Fee : Use Tax Total ~B,S d $0.00 (OWNER)(CONTRACTOR) SIGNED G.~DATE_ DescriptionILA~ zK~SC(gCjCRS& v+l f;U-1 I-t tE&5!~$'-~(DYo Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: hm.~~~r~.~a~t~l~~ p-. ' Ai~ ~ (1) This permit was issued in accordance with the provisions set forlh in yopur application antl is subject to the laws of the Sfa[e of Coloredo and to the Zoning Regula[ions and Buildinq Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authonzed is not wmmencetl within sixty (60) days 6om issue date or (e) the building authonzetl is suspended or abantlonetl for a penotl of 120 tlays. (3) If ihis pertnit expires, a new permit may 6e acquired for a fee of one-half the amount normally required, provided no changes have been or will be matle in the original plans antl specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, (ull fees shall 6e paid for a new permit. (4) N'o work of any manner shall be tlone thatwill change the natural flow of water causing a drainage problem. (5) Con[rac[or shall notify the Building Inspector iwenly-four (24) hours in advance for all inspedions antl shall receive wntten approval on inspection card before proceediing with successive phases of the job. (6) The issuance of a permit or the approval of tlrawings and specifcations shall not be consWetl to be a permit for, nor an approval of, any violatlon of the provisions of the building wtles or any other ordinance, law, rule or regulation. Chief Building inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION