Loading...
HomeMy WebLinkAbout22 Rangeview DriveThe City of Wheat Ridge Third Party Form Check List Property Address 22 7,) 0 : 6 0:2 Permit Number C Permit Issued Date Owner Information Property Owner Information Ll ee4vdz Property Owner Address Inspector Information Inspection Company s L.LC Inspector Name -D ,� ,., k2Q �tv Inspector Contact info. CG 1- , o �y / Inspector Statement and Acknowledgement * I hearby acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * I hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's Date: Property Owner Statement of Acknowledoement *1 hearby acknowledge that 1. am the ownerpf the building referenced above and I give my consent for the listed third ins o company to perform my roof ins ection in lieu of the City of Wh t -R, i g ui 'Di ion inspection. Propery Owner/Agent:4 Date: This original document an permit card, as well as the roofing check list, must be submitted tt the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W. 29th Ave Wheat Ridge CO 80033 Draft Date: 7/26/17 Please add note to reverse side Roof Insoection ❑ N/A ❑ Pass ❑ Fail ❑ N/A ass 171 Fail F-1 N/A ass lass E] Fail ❑ N/A Pass ❑ Fail gN/A ❑ Pass ❑ Fail AN/A ❑ Pass ❑ Fail �A ❑ Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A P_ Pass ❑ Fail N/A ❑ Pass ❑ Fail ❑ N/A — Pass ❑ Fail ❑ N/A ,� Pass ❑ Fail ❑ N/A ® Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A Pass ❑ Fail AN/A ❑ Pass ❑ Fail N/A ❑ Pass ❑ Fail N/A ❑ Pass ❑ Fail N/A ❑ Pass ❑ Fail N/A ❑ Pass ❑ Fail N/A ❑ Pass ❑ Fail The City of Wheat Ridge Inspection Check List notes Mid -Roof Structural roof components Verify that no more than 2 layers of shingles exist Flashing for roof and walls If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Verify sheathing nail pattern (See Policy & Procoduros) Crickets and saddles where needed Verify B vent must have boot same gauge as pipe Verify vent caps Verify no flashings are damaged or rusted Step flashing shall be min. of 4x4 piece per shingle Verify scuppers allow for proper drainage Ice and water shield 2' in heated wall spaces Underlayments must follow 2012 IRC / 2012 IBC Verify roof slope for proper drainage Dripedge shall have min of 2" overlap Dripedge should extend down min 2" past roof deck Dripedge shall be mechanicaly fastened 12" OC 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages; patios, carports, open on three sides with min. slope of 1:12 Modified Bitumen, EPDM, TPO min slope 1/4:12 slope Above roof insulation R-25 Below roof residential R-38 Below roof commercial R-32 Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final inspection (Metal Roof Shingles ReguirementsReguirements ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment C C The City of Wheat Ridge Inspection Check List notes Mid -Roof Notes Company Name: Inspector signature: Date of Inspection: r _��1�0.GOL' The City of Wheat Ridge Inspection Check List notes Final Roof Roof Inspection ❑ N/A ❑ Pass ❑ Fail ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A Pass ❑ Fail Verify that no more than 2 layers of shingles exist /15 Pass ❑ Fail Flashing for roof and walls �N/A ❑ Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) MN/A El Pass F-1pailVerify sheathing nail pattern (See Policy & Procedures) N/A ❑ Pass ❑ Fail Crickets and saddles where needed ❑ N/A JO Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A Pl- Pass ❑ Fail Verify vent caps ❑ N/A O—Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A 11Z Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle I N/A ❑ Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A 'In Pass ❑ Fail Ice and water shield Z in heated wall spaces ❑ N/A Eg- Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A [1 Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A t] Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A V1 Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A ?T Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC Njq ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope; Exception: detached garages, i patios, carports, open on three sides with min. slope of 1:12 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope N/A ❑ Pass ❑ Fail Above roof insulation R-25 N/A ❑ Pass ❑ Fail Below roof residential R-38 N/A ❑ Pass ❑ Fail Below roof commercial R-32 N/A vv El Pass EJ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturer's specifications - Must have manufacturer's letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less t 3:12 N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as /A ❑ Pass ❑ Fail roof Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope l Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Final Roof Notes Company Name: Inspector signature: Date of Inspection: INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day PERMIT: � 3 ADDRESS: JOB CODE: (Foundation Inspections I Date I Inspector I Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 1106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections (Underground / Slab InspectionsI Date I Inspector I Initials Comments 1201 Electrical / Cable/ Conduit I 1202 Sewer Underground Int. I 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plum d Ext. 1206 Water Underground I I Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections SEE OVER FOR ADDITIONAL INSPECTIONS PERMIT: A v IIL, _ JK, 3 ADDRESS: � � �� JOB CODE: �= Final Inspections Date Inspector Initials Comments tough Inspection (continued) 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace - 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door � � ( L�� 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* --] 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. PERMIT: ;a3 ADDRESS: "; JOB CODE: ' Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler/ Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous f,' / ,.M:. ` `i, p A)Sefabl s, 31�i1� f I Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof f,' / ,.M:. ` `i, p A)Sefabl s, 31�i1� f I 410 Final Window/Door 'LAE 411 Land scape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. U0 INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day l PERMIT:C ADDRESS: ,;, ' - JOB CODE: Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS The City of Wheat Ridge Third Party Form Check List Property Address -9 - J ; e- Permit Number 0 t 2 0c2 Permit Issued Date Owner Information Property Owner Information �✓'l� (f e &4o C Property Owner Address — 0c 10 11, Inspector Information Inspection Company 1"7^, rz La" Z -L C. Inspector Name _7>,-9 Inspector Contact info. _71-0 Inspector Statement and Acknowledgement I hearby acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * I hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's Ins Date: 1 -/S —/7 Property Owner Statement of Acknowledgement *1 hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third ins mpany to perform my roof ins ection in lieu of the City of Wheat RRid� ui Di ion inspection. Propery Owner/Agent: y' 1 Date: This original document and permita d, as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W. 29th Ave Wheat Ridge CO 80033 Draft Date: 7/26/17 Please add note to reverse side Roof Insuection ❑ N/A ❑ Pass ❑ Fail ❑ N/A Requirements ❑ Fail N/A tPass ass L]Fail [� N/A ass ❑ Fail ❑ Fail ❑ Pass ❑ Fail N/A ❑ Pass [:1 Fail X_b/A ❑ Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A} Pass ❑ Fail ❑ N/A Pass E] Fail ❑ N/A r X Pass ❑ Fail N/A ❑ Pass ❑ Fail ❑ N/A fig—Pass ❑ Fail ❑ N/A ,� Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A Pass ❑ Fail FN/A ❑ Pass ❑ Fail /A ❑ Pass ❑ Fail /A ElPass ❑ Fail /A fN ❑ Pass ❑ Fail /A ❑ Pass EJ Fail /A ❑ Pass ❑ Fail The City of Wheat Ridge Inspection Check List notes Mid -Roof Structural roof components Verify that no more than 2 layers of shingles exist Flashing for roof and walls If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Verify sheathing nail pattern (See Policy & Procedures) Crickets and saddles where needed Verify B vent must have boot same gauge as pipe Verify vent caps Verify no flashings are damaged or rusted Step flashing shall be min. of 4x4 piece per shingle Verify scuppers allow for proper drainage Ice and water shield 2' in heated wall spaces Underlayments must follow 2012 IRC / 2012 IBC Verify roof slope for proper drainage Dripedge shall have min of 2" overlap Dripedge should extend down min 2" past roof deck Dripedge shall be mechanicaly fastened 12" OC 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 Modified Bitumen, EPDM, TPO min slope 1/4:12 slope Above roof insulation R-25 Below roof residential R-38 Below roof commercial R-32 Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements /A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope Im 3:12 /A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof /A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment 0 D G The City of Wheat Ridge Inspection Check List notes Mid -Roof Notes Company Name: Inspector signature: Date of Inspection: 1Sk LJ N/A ED N/A rh N/A N/A N/A N/A N/A /A C N/A The City of Wheat Ridge Inspection Check List notes Final Roof Structural roof components Verify that no more than 2 layers of shingles exist Flashing for roof and walls If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Verify sheathing nail pattern (See Policy & Procedures) Crickets and saddles where needed Verify B vent must have boot same gauge as pipe Verify vent caps Verify no flashings are damaged or rusted Step flashing shall be min. of 4x4 piece per shingle Verify scuppers allow for proper drainage Ice and water shield 2' in heated wall spaces Underlayments must follow 2012 IRC / 2012 IBC Verify roof slope for proper drainage Dripedge shall have min of 2" overlap Dripedge should extend down min 2" past roof deck Dripedge shall be mechanicaly fastened 12" OC 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope; Exception: detached garages, patios, carports, open on three sides with min. slope of 1:12 ❑ Pass ❑ Fail Roof Insaection ❑ Pass ❑ Fail ❑ N/A ❑ Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A E9 Pass ❑ Fail N/A D Pass ❑ Fail warranty with the address on the letter for final inspection ❑ Pass ❑ Fail N/A ❑ Pass ❑ Fail N/A ❑ Pass ❑ Fail ❑ N/A P Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A O—Pass ❑ Fail ❑ N/A Pass ❑ Fail /q ❑ Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A P - Pass ❑ Fail ❑ N/A Pass ❑ Fail ❑ N/A [� Pass ❑ Fail ❑ N/A] Pass ❑ Fail ❑ N/A Pass ❑ Fail )�N/A ❑ Pass ❑ Fail LJ N/A ED N/A rh N/A N/A N/A N/A N/A /A C N/A The City of Wheat Ridge Inspection Check List notes Final Roof Structural roof components Verify that no more than 2 layers of shingles exist Flashing for roof and walls If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Verify sheathing nail pattern (See Policy & Procedures) Crickets and saddles where needed Verify B vent must have boot same gauge as pipe Verify vent caps Verify no flashings are damaged or rusted Step flashing shall be min. of 4x4 piece per shingle Verify scuppers allow for proper drainage Ice and water shield 2' in heated wall spaces Underlayments must follow 2012 IRC / 2012 IBC Verify roof slope for proper drainage Dripedge shall have min of 2" overlap Dripedge should extend down min 2" past roof deck Dripedge shall be mechanicaly fastened 12" OC 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope; Exception: detached garages, patios, carports, open on three sides with min. slope of 1:12 ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope ❑ Pass ❑ Fail Above roof insulation R-25 ❑ Pass ❑ Fail Below roof residential R-38 ❑ Pass ❑ Fail Below roof commercial R-32 ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturer's specifications - Must have manufacturer's letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements ❑ Pass Fail Metal roof shingles shall not be installed on slope less 3:12 ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Final Roof Notes �(� � w � i -i � _ � �r� c � ✓� S Til lG�/ 6-1 Company Name: Inspector signature: Date of Inspection: City of Wheat Ridge d�s Residential Roofing PERMIT - 201709323 PERMIT NO: 201709323 ISSUED: 11/29/2017 JOB ADDRESS: 22 Rangeview DR EXPIRES: 11/29/2018 JOB DESCRIPTION: Residential re -roof on house and shed with synthetic shake shingles, class 4 impact, class A fire, 115 mph. Pitch is 9/12 with 42 total number of squares. *** CONTACTS *** OWNER (303)237-3219 HECTOR GAYLE A SUB (303)596-3936 John Gendreau 100321 John Gendreau *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2404 / APPLEWOOD KNOLLS, PARAMOUNT HE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 42,000.00 FEES Total Valuation 0.00 Use Tax 882.00 Permit Fee 637.55 ** TOTAL ** 1,519.55 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201709323 PERMIT NO: 201709323 ISSUED: 11/29/2017 JOB ADDRESS: 22 Rangeview DR EXPIRES: 11/29/2018 JOB DESCRIPTION: Residential re -roof on house and shed with synthetic shake shingles, class 4 impact, class A fire, 115 mph. Pitch is 9/12 with 42 total number of squares. I, byy� my si nature, do hereby attest" that the work to be performed shall comply with all accompanying approved plans and specifications, applicable ilding codes, and 11 applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal rt�r of the pro erty and am authof�',zed to obtain this permit and perform the work described and approved in conjunction with this permit ; er h t m legally 4utfiorized to include all entities named w' in this,document as parties to the work to be performed k e performed is disclosed in this document and its' accomp�ying approved plans and specifications. 'dig aftir$'of OWNER or CONTRACTOR (Circle one) Date L � Ihis permit was issued based on the information provided in the permit app'kation and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. his. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be retired to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Offiial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordman,e. or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. �O1--)- 6g32 Dina Kemp From: no-reply@ci.wheatri dge.co.us Sent: Tuesday, November 28, 2017 3:06 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address 22 Rangeview Dr. Gayle Hector 303-237-3219 Field not completed. 17 Do you have a signed Yes contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Hector roof.pdf Contract CONTRACTOR INFORMATION Contractor Business John Gendreau LLC Name Contractor's License 100321 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-596-3936 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 27 Rangeview Dr.42 (Primary address of your business) Contractor Email Address john111546@yahoo.com Retype Contractor Email john111546@yahoo.com Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work: Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or both? (check all that apply) 42 $42,000.00 we Pitched roof (2:12 pitch or greater) 18 What is the specific pitch 9/12 of the PITCHED roof? How many squares are 9/12 part of the PITCHED roof? Describe the roofing synthetic shake shingles materials for the PITCHED roof: Type of material for the Other PITCHED roof: If "Other" is selected Synthetic shake shingle, Class 4 impact, Class A fire, 115mph above, describe here: Provide any additional House and shed detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal 19 owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant John Gendreau Email not displaying correctly? View it in your browser. 20 John Gendreau LLC 303-596-3936 11/28/2017 Hector Residence 22 Rangeview Dr.. Wheat Ridge, CO 80033 Proposal: Remove and replace existing damaged shingles with 50 yr. CeDUR shake shingles. Provide ice and water shield at all eaves with 30# paper through out. All work to to be performed in a timely and professional manner conforming to City of Wheat Ridge building codes. Total: $46,000.00 Payment of 50% when shingles delivered; balance after final inspection. Warranty: nanufactures warranty on the product. Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS .106 FOUNDATION INSPECTIONS Footings /Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof/ French Drain Sewer Service Lines Water Service Lines DATE I ;Z wrt INITIALS COMMENTS: CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) ROUGHS Sheathing Lath /Wall tie - Mid -Roof Electrical Service Rough Electric - Rough Plumbing Gas PiDino Rough Me ABOVE INSPECTIONS TO BE SIGNED PRIOR rn oanrvrnuir_ Framing - Insulation Drywall Screw FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department - R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping I CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND.ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED.. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. II'1/ f Inn kli ,, kl-- 11— ____ -- -- •- •� 1 �- arclvu I t to U I IL ULK I IFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER- `i, A s CITY OF WHEAT RIDGE ° Building Inspection Division 6 � 111111 (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: /n —, ) /4� f gc I it rver �i,, i ❑ No one available for inspection: Time /d;%{ AM ISM Re- Inspection required: Yes No When corrections have been made, call for re- inspection at 303- 234 - 5933 i r ; Date: Inspector: DO NOT REMOVE THIS NOTICE ., ..a,• s ;.... ^=t'^, -.- k -_ z .:mec.,. ` r�c. - ,+s( Via._ � _ ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: _ owi1_vA5wi= Job Address: Permit Number: lbD3Yo ,�PPQo �f ❑ No one available for inspection: Time 7. '3 /A W PM Re- inspection required: -Yes (to- * When corrections have been made, call for re-inspection at 303 -234 -5933 Date: 3 23 iD Inspector: DO NOT REMOVE THIS NOTICE of m"~"' City of Wheat Ridge Building Division Date., R, 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 Plan Inspection Line: 303-234-5933 °toaao Permit Building Permit Application Property Owner (please print): Mailing Address: (if different than property address) Address: State, Zip: oNl~:G;kA : Contractor License e4-,:91q6 Phone Electrical City License Company: Plumbing City License Mechanical City License Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction Value: 7c~ . , (as calculated per the Buffding Val anon sheet) OEM' 1i r~~, L fC w jY.Ylc )G /C ~~c~ LJ L' Plan Review (due at time of submittal): $ li`%✓ji~Y~''k`'~`~~1a Sq. Ft./L.Ft-added: Squares_ BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OW ER) (CONTRACTOR) or PERSONAL REPR . Et7 ATIV ~O NER) (CONTRATOR) PRINT NAME: 1 1/TaF'k 971t'!%~1 SIGNATURE: % Date: H a w o o . _ ~ .N v Z W > 0 a U) ~ Z O ~N = w > M (D N W y M M IL) ~ • L N C M ~ N U _ 0 U v~ ~ U N N d ~ a V Q L O 7 c~ v ~ ~ 1 U ~ ~ IV A~ r% ~ ~ ~ 0 u d Q 0, _ ~ ~ w m ~ ~ a co E c Q) a) ~ ~ > m ~ N C O C'i U {y N T ~ N 04 U~ = N ~ > O > M 4rn City of Wheat Ridge Residential Electric PERMIT - 060338 PERMIT NO: 060338 ISSUED: 05/09/2006 JOB ADDRESS: 22 R.FaNGEVIEW DR EXPIRES: 11/09/2007 DESCRIPTION: elec. for pop-top/bedroom, bathroom, closet, mech, etc. CONTACTS gc 303/989-1404 Kenneth B. Shulz 02-1817 KS Electric owner 303/237-3219 Gayle/JOAnne Hector PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION: UA BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 2,750.00 FEES Permit Fee 108.30 Total Valuation .00 TOTAL 108.30 Comments: electrical for pop-top: bedroom, bathroom, closet, mechanical, sitting area reference permit #016636 Must meet 2002 NEC, subject to field subject I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules cr regulations of the City of Wheat Ridge ar covenants, easements or restrictions of record; that a11 measurements shown, and allegations made are accurate; that I have read and agree [o abide by all conditions printed on this applicatio and that I assume ~.µll responsibility for compliance with the wheat Ridge Building Code (I.B.C) and all o[her applica 1]he~f ~d4Or,~inYyes, for work under this permjt./lans subject to field inspection. Sinature of contractor/ownqe~ / / date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any oCher applicable ordinances of the City. 2. This permit shall expire if (A) Che work authorized is not commenced within eixty (60) days from isaue date or (H) the building authorized is suspended or abandoned for a period of 180 days. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in [he original plans and specifications and any suspension or abandonment has noC exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 9. No work of any manner shall be done [hat will change the natural flow of water causing a drainage problem. 5. Contractor shall . no[ify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval. on inspec[ion card before proceeding with auccessive phases of the job. 6. The issuanre of a permit or Che approval of drawings and specifications shall not be construed [o be a permit for, nor an apprwal of, an violation of the prwisions of the building codes or any other ordinance, 1aw, rule or regulatiov. all plan re ' sub' to fiel spectiona. ' ~ of date INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3Pht ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 1-- a w 0 H Z W 2 a 0 W W ~ ~ F- Z ~ ~ 0 L) c 0 .N ~ ~ C~ N M ~ N U) M CM 0v V a) Q N C a+ 0 Z ~ ~ 0 w ~ m a N C L { e N ~ ai ~ l f6 ~ C ~ N N A ~ m ~ L N C O M ~ N OMf O ~ b 'O ~ V M Q C N 0 > M DF WHEAl ~ 'P City of Wheat Ridge Building Permit Number: ~ ~ m Community Development Department Date: c~CORP00 .IR;LINOR . .R",! UILdING PERAC:R'IT~~PLIGA4' IC61 C Property Owner: 6QY 1e SQ A n(10~, Property Address: ~a (Zcic1ce' '3 ~ euJ pl • Contractor License No.: .91917 rnone: 303-a 37- 3a14' Company: KS Phone: _2Z3-QeQ-I C(OLl OWNEWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Buildina Dept. Valuation Figure: $ d750=' I hereby certify that the setback distances proposed by this permit application are accurate, and do nobviolate applicable ordinances, rules or regulations of ihe City of W heat Ridge or covenants, easements or reslrictions of record; fhat all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibiliry for compliancewiththeWheatRidgeBuildCode(I.B.C)and ther applicable Wheat Ridge Ordinances, for work under thrm)t. PJanWsuqje t o field inspectiog. / (0 W NER)(CONTRACTOR): V31Ue:$ Permit Fee:$ Plan Review Fee:$ e Tax: Total:$ a7so Use of Space (description): Bta~COr9,y1. GOA i C,l tNXC'CAQAiCo_\ Description of work: J A~d gogEo~ ~nd leue-\ ov,, 'v\ou s~_- , Sq. Ft. added . ~ e BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: Approval: Zoning: COMMENTS: Approval: WORKS COMMENTS: Approval: 'i 6&36 IRE DEPARTMENT COMMENTS: Approval: Lcupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Plumbing License No: Mechanical License No: Company: VS EIEG'1;~.c:. Company: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Coiorado and to lhe Zoning Regulations and Building Codes of Wheat Ridge, Cobrado or any other applicable ordinances of Ohe City. (2) This pertnit shail expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been orwill be made in the original plans and specifcations and any suspension orabandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, fu II fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector lwenty-four (24) hours in advance for all inspections and shall receive wrilten approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permil for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, role or regulation. All plan review is subject to field inspections. Chief Building Official COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 16636 BUILDING INSPECTION LINE -(303-234-5933) Date : 1/9/2004 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: GAYLE A. HECTOR Property Address : 22 RANGEVIEW DR Phone : 237-3219 Contractor License No. : Company : Phone : OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $35,000.00 I hereby certify that the setback distances proposed by this permit application are accurate, and Permit Fee : $640.00 do not violate applicable ordinances, mles or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations Plan Review Fee : $416.06 made are accurate; that I have read and agree to abide by all conditions printed on this ' $700 00 applicalion, and that I assume full respons Iky for compliancg with the Wheat Ridge Building US8 T8X : . Code (U.B.C.) and all other applicable i At Ridge rdii a Ces, or work under this permit. pI Total : $1,756.00 ^ D ^D (OWNER)(CONTRACTOR)SIGNE DATE Use : Description : ADD 2ND FLOOR LEVEL ABOVE EXISTING STRUCTURE . 2ND LEVEL W ILL HAVE 2 ROOMS AND A FULL BATHROOM tt S'2S2\ BUILDING DEPARTMENT USE ONLY Zaning. Gortjmentssi Approval : MR Zoning : R-1 Building Cpmmenti.-: Approval: DM Rubltc Wqrks Coinimants: Approval : Occupancy: Walls Electrical License No Company: Expiration Date : Approval: SIC : Sq. Ft. : 11/12103. CANNOT ENCROACH INTO EXISTING NON-CONFORMING SETBACK FROM RANGEVIEW PL. PEet►se Note: Owner / contractor is responsible for tocating property OK. 1I8I04 lines and constructing improvements according to the apptoved plan and reyuired development standards. l'he City is not responsible fur inaccurate infomiation submitted within the plan set and any construction errors resulting from inaccurate information. Roof : Stories : Residential Units : Plumbing License No : Company: Mechanical License No : Company: Expiration Date : Approval: Expiration Date : Approval: (1) This permit was issued in accordance with the provisions set foRh in yopur application and is subject to lhe Iaws of the Slate of Colorado and to the Zoning . Regulations and Building Code of W heat Ridge, Colorado or any other applicable ordinances of the City (2) This pertnit shall expire if (A) the work aWhorized is not commenced within sixry (60) days from issue date or (B) the building authonzed is suspended or abandoned for a period of 120 days. (3) If this permit expires, a naw pettnit may De acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifcations and any suspension or abandonmeN has not exceeded one (1) yeac IF changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the naWral flow of water causing a drainage problem. (5) Contractor shatl notiy the Building Inspector hvenry-four (24) hours in advance for all inspectians and shall receive wntten approval on inspection wrd before pmceediing with successive phases of the job. (6) The issua eWf a permit o the approval of drawings and specifcalions shall not be conSVUed to be a permit for, nor an aDProval of, any violation of the pmwsie of li ~des or any other orUinance, law, rule or regulatioa . ti~l}y-.~ c ' Chief Building In ector Please sign Terms and Conditions on reverse side of page. COMMUNITY DEVELOPMENT DEPARTMENT Building Pemvt A'umber: O V1ME9 gUILDING INSPECTIOA' LINE - 303-234-5933 Date: CITY OF WHEAT RIDGE u m 7500 WEST 29TH AVENUE L3~ W'HEAT RIDGE, CO 80033 - (303-235-2855) COL OR Aa~ APr a` jp~ ~411.?'f / dg~` ON Property Owner: Property Address: D, a. RAnI Gc v/E'u~ D I= Phone :30 3- o~ 37 ^ 3r~ ~ q Contractor License No.: Company: Phone: ONTER/CORTRACIOR SIGNATURE OF GSDERSTAIDING A.KD AGREEDIENT ( 1 hereby <cnify that the setback distances proposed by (hrs permit appliwtion are accurate, and do not violatc applicablc ordinancu, rula ortegulations of the City of Wheat Ridgc or covcnan6, cascments or restnctions of record; thal all measurertwnt5 shown, and allegations made arc accuate, that I have read and agrtt to abide by alI condiGons pnnted on this application and that I assurtre full ttsponsibiliry for mmpliance with the WI¢at Ridge Building Code (U.B.C) and all other appliyple Wheat Ridgc Ordinancu, for work under this pertnit. //Y I jONTERHCONTRACTOR).SIGN~~l~.,~Nd / (OwTER)COMRACfOR)'PRIMEDC-A-/If' A I'Ii-C 7'QQt DATE JI 0~, DESCRIPTIO\: «mt~ a,..,r}Z Construction Value:$35, 000.°n Permit Fee:$ ~r°K .c:: Plan Review Fee:$ USe T3X:$ Total:$ _.2L"--c A BUILDIA'G DJEPARTMENT USE ONLY S ~r J.. ZONIN6 COMMENT3: (~Approval: Zoning: . BUILDING COMMENTS: Approval: ~ c PU6t1C WORKS COMMENTS: Appzoval: r .•.ii v Occupuuy: Walls: Roof: Stories: Electrical License No: Company: Plumbing License No: Company: NOo 1 '1 Sq.Ft.: Residential linits: Mechanical License No: Company: Expiration Date: Expiradon Date: Expiration Dace: ApprovaP Approval: APProval: (q Thu pemnl uss issued in accordance with the provisions set foM in ywu apylicauon and is subj«i io the 6ws of the Som of Cobndo and m tA<Zuning Reguhtiora and BuiWing Coda of K'heat Ridge, Cobndo or any oiher applicabk ordimnces of the Ciry. This pa+nit shall upirt i((A) the uork aulhorizM i5 na commenced within sixry (60) days fiom issuc daa or (B) thc building aulhonzed is suspcnded or abandoned for a pmad of 120 days. If Ihis yermil expims, a ncw permil may be uquieed for a ftt of onehalf the amowt normall) tryuirtd, provided no ahanges have betn or u ill be made in the origiml pWis and spxi&ation5 and any suSpension a abandonmrnl hu nW euttded one (1) year. If changu tuve bern or if susprnson or abandonmem <xceeds one (1) yeu, full ket shail be O+d for a neopemiit- (4) tio Ww4 of any manna slull be dane Aut will chmge the mNnl 1bw af wa1er causing a Minage probkm. (5) Coneacwr shail noriry the BuiWing Inspeemr twrnry-fav (20) hours in ad.aMe for a0 inryec6ons and shall reccn'e wnncn approwl on msycccon urd yefm procxding with successive phaxs of the job. (b) Ths isswnce of a permit rn the appronl of dnwings and specificauons sh+ll not be conswed b be i pemin fw. nor an approval af, any v'wlauon of ihe pmrisions (~IM1e buiWing codes or my other ordinanee.6w. rule or rcgu6eon. 1c Chief Building I ector Inspection Services Division Buildin¢ Plan Review Comments Address: 22 Rangeview Drive Owner: Hector Project: SFD Addition llate: November 24, 2003 Contractor: Homeowner Ocxupancy: Rl3 Valuation: 1. Provide a letter from the engineer stating an inspection of the existing foundation shows it can carry a econd floor. 2.~Provide a complete floor plan of the existing and proposed home with dimensions and room uses. 3.~Provide all window sizes and typed. 4. Provide complete electrical, plumbing and mechanical plans. 5. Provide a guardrail detail for the proposed deck at front elevation 6. Provide manufacturers specifications on proposed stucco system to be installed. 7. Provide detail showing how 2x members are to be attached to W18x46 I-beam. 8. Provide floor framing detail for new stairway area. 9. Provide an itemized break down of construction value to verify $35,000 valuation, appears to be low. Please make these additions or corrections to the submittal and resubmit for review, if you have any questions please contact me at 303-235-2853. Thank Y/ou~ Darirl'Morg n BO Codes Ad ' istrator 0 4 F wHE,y r ~ h Q 4~ U fn c~~ OR ADO Inspection Services Division Bnildins Plan Review Comments Address: 22 Rangeview Drive SECOND REVIEW Owncr: Hector Contractor: Homeowner Project: SFD Addition Occapancy: W3 Valuation: $45,400 llate: December 15, 2003 1. The letter from the engineer does not address the existing foundation and walls and whether it can carry a second floor and roof loading. 2. Provide a complete floor plan of the existing and proposed home with dimensions and room uses. 3. Provide all window sizes and typed. 4. Provide complete electrical plans showing outlet locations, smoke detectors, label AFCI and GFCI outlets and show electric service location on plan. (underground or overhead service proposed?) 5. The proposed 2x members are to be attached to W18x46 I-beam by way of bolts unless specifc screw type is listed and stamped the engineer of record. Please make these additions or corrections to the submittal and resubmit for review, if you have any questions please contact me at 303-235-2853. Thank~ Darin Morg , 0 Codes Ad in trator O P 4 E WHEqT h Q 4~ V m ~OL OR A00 Inspection Services Division guH inp plan Review Comments :iddress: 22 Rangeview Drive SECOND REVIEW O,ivncr: Hector Cuntratikor: Homeowner 1'rojec:t: SFD Addition Oixupancy: Rl3 Valiwtion: $45,400 llakc: December 15, 2003 1. The letter from the engineer dces not address the exisiing foundation and walls and whether it can carry a second tloor and roof loading. 2. Provide a complete floor plan of the existing and proposed home with dimensions and room uses. 3. Provide all window sizes and typed. 4. Provide complete electriwl plans showing outlet bcations, smoke detectors, label AFCI and GFCI oullets and show electric service location on plan. (untlerground or overhead service proposed?) 5. The proposed 2x members are to be atlached to W18x46 I-beam by way ot bolts unless specific screw type is listed and stamped the engineer o( record. Please make these additions or corrections to the submittal and resubmit for review, if you have any questions please contact me at 303-235-2853. Thank You1J Darin Morg , 0 Codes Ad mj5trator Gayle & Joann Hector 22 Rangeview Dr. Wheat Ridge, CO 80215 Wheat Ridge Building Dept. The following is a breakdown of the proposad cost to complete the addition to my residence located at the above address. I anticipate doing the majority of the work myself with subs doing the stucco and roofing. Framing materials Trusses Steel Frame labor Windows & door Roofing Stucco Electrical Plumbing Heating Insulation Sheetrock Paint Interior Trim Carpet $5500.00 8000.00 800.00 7000.00 1800.00 7500.00 6000.00 400.00 1000.00 2000.00 1000.00 1000.00 400.00 1000.00 3000.00 Total $45,400.00 Dec 10 03 04:31p MGM Supply L'o 13031789-0147 p.l is LEGACY R1=PORT ER-4842 Reissued March i, 2003 ICC Evaluatfon Service, ItlG. ~~~~~onal Oflka# 5380 WMkmari Md Rwtl. WM1il6er. Ceflania 9D601 N(562) 699-0543 Rplonal OfPae b 900 Mon0lar RoaQ Suita A, Btrmnghem, AteUama 35213 8(205) 599-9800 www.icc-es.org Reglonsl0lHnekI051WestflosamoorROaqCamUyClubHilk.Illnois66QeM(708)]992305 Legacy report on the 1987 UnJform Bulldtng Code'"' CATEGORY; EXTERIOR COATINGS GREY COUCHE EXTERIOR S7UCCO 3Y'iTEM PAREX, INCORPORATED POST OFFICE BOX 188 REDAN, GEORG{A 30074 1.0 SUHJECT Grey Couche Exterwr Stucco System. 2.0 D@3CRIPTION 2.1 Generaf: The Grey Couche Stucco Syslem is a proprietary mixture o( portiand cement, sand, water and proprietary ingredients reinforced with wire fabnc or melal lath which is applied to substretes of expanded polystyrena ([PS) insuietion board, extruded polystyrene insulation board, Monsanto Fome-Cor 8oaro, gypsum sheathing, plywoodorflbertoartl. The system is installed on eMerior walis of wpaf or steel stud construction. 2.2 Materials: 2.2.1 Grey Couche Stucco: A factory-pa3pared mixNre of Type I or Type 11 port{and cement complyng with ASTM C 150, lime complying with ASTM C 206, sand complying with Section 2.2.3 and propnetary additives. The miMure is packaged in 75-pound bags. Approaimatety 1'!, gallons of water are adtled to each bag in the field ard mixed in accordance with manufacturer recommendations. The product is available in a gray color. 2.2.2 Sand: Must be clean and free from deleterious amounts of loam, clay, silt, sohibie salts ard organic matter. Sampling and testing must comply with ASTM C 144. Sand must bo graded within tho follown9 limits: RETAINED ON U.S. STAIiOARD SIEVE PERCENT RETAINEU BY WEIGHT 2 2 PERCEiNT Mlnimum Maximum No.4 - 0 NU. B O 10 No. 16 10 40 No.30 30 BS N0.50 70 90 Nu. 100 95 1 W 2.2.3 InsulaUon Board: 1.2.31 EPS: Expanded polystyrerre (EPS) insuiationboard has a nominal density of 1.5 pounds per cubic foot, a Ctass t tlame-spread Gassification and a smoke-tleveloped reting not exceeding 450. Unbacketl boaros are i inch to 1'/, inches thick and have'f,•inch-high tongueswith compatible grooves fnr horizontal jants. See Figure t for joint detaiL All boards must heve recognition in an evaluation report issued by ICC- E5. Soo Soction 26 for board identification. 22.5.2 Extruded Polystyrene: EztruAed polystyrene insulation board has a nominel densRy of 1.6 pounds per cubic foot, a Class I flame-spread daseilcation and a smoka developed rating not exceedng 450. See Secfion 21.31 for additional requireinents. 2.2.4 Fomo-Cor Board: Nominal '/,-inch-thick eMruded porystyrene foam plasNc identified as Fome-Cor Board in evaluation report ER-3335. 2.2.6 lath: 2.2.6.1 Wire Fabric Lath: Minimum No. 20 gage 1-inch galvanized steel woven wire tabria Lath must be self-turred or furred when appliad over alI substratas except unbacked polystyrene board. Limftetions on'mstallations with self•furnng No. 20 gage wre fabric are as follows. 1. The meximum total coating ihickneu is'Ir inch. 2. Furring crimps must be provided af mazimum 6-inch intervals each way. The cnmps must fur the body of the lath'!, inch minimum from the substrato aflor instaliation. 2.2.5Z Metal Lath: Complies with Tabie 25-6 of the 1997 Uniform Building CodeTM (UBC). Furring and self-furring requirements are as sot forth for tho wire-fabric leth. 2.2.6 Gypsum Sheathing Board: Water-resistant core gypsum sheathing canplying with ASTM C 79. 2.2.7 Fiberboard: Minimum '/,-inch-thick asphait- impre9nated fiberboard complying with ANSItAHA A 194. 1- 1985 as a regular density sheathing. 2,2.8 plywood: Minimum '/,s inch-thick plywood with eMerior glue for studs spaced 16 inches on center and minimum 'la inch•ttiick plyvrood with exterior glue for skuds spaced 24 inches on canter. Plywood complias with UBC Standard 23-2. 2.2.8 Caulking: ACrylic latex caulking material comptying with ASTM C 834. 22.10 WeatherrosisHve Barrier: Minimum Gr2de D krak building paper complying witb U8C Standard 14-1 or asphalt- saturated reg felt complying with UL 55-A. The weatherv resistive barrier is pleced over all substretes except for foam plastic insulalion board v+here the barrier may be behind the ~CCSfg .p e A mn J. y ~ F hn n~ud~.annDuie ~ y'l~ollP lAeJ.nnrurc@nYn, DernmrnsJas ' dn ..rn ~l m b/ I J A pur . ~M 1 ~ . Iboe H na x urru Af Il.(. Avaluul - V' re In. e~ryefx onin! Lf m N ~ N.. . n. m in~ pnde v..n.l he eiv .,p. n Copyrqhl 0 2003 P.pe 1 uf 6 Dec 10 03 04:32p MGM Supply Co 13031789-U14; r.. ER3842 Paga 2 of 6 boartl. Application ofthe barrier complie5 w th Section 1402.1 of the UBC. When applied over any wood-based sheathing, the barrier must be a minimum lwo laYers if Grade D paper as set foRh in Section 2506.4 ot the UBC. 2.2J1 Atlmixture: PrOpnetary ingrediel[s included to improve quality of coating mixture. 2.2.12 Miscellaneous: All tnm, screod end corner reintorcoment must be galvanizetl steel or approved plastic. 2.3 Installatlon: 2.3J General: The exlenor cementitious :oating is apptied by hand trowafing or machine spraying n oo~ coat tu a minimum'l, inch thickness, '/a inCh minimum thickness ot texture hnish cAat is added, uNess notetl otherwise in this report. The lath must be embedded in the minimum coating thickness and therefore cannot be exposed. Finish coat must tre applied vrithin 48 hours aker the base, croat unless the latler is sprayed/brushed with an approvod acrylic bonding adhesive, or an approved bondng treatment is added to the finlsh coat stucco miz prior lo finish r.oat application. Fasteners for Vath must penetrate 1 inch mmimum into wood etuda. Flaehing, comer reinfacement, me':el trim and weep screeds must be installetl as shown in attached tle[alis. Weep screeds and their inStailation must comply w4th UBC Sections 1402.1 and 2506.4. See Figure 3. The coating is applied at ambient temperature ranging hom above 40'F to 1707 by applicators approved by Paiex tnc. Tbe .veather-resistive barrier must he applied as set forth in Secfion 22.10. An installation card, as noted in Figum 2 must be on tha jobsite with the name of the applicator and the product to be usod, before any weaiher-resistive barrier or eMerior sheathing is installed. Alao, sae Section 4.8 of this reporl. 2.3.2 Applicadon Over Open Framing: 2.3.2.1 EPS or Exdudad Polystyrene Irsulatbn Board: Tha weathnr-iesistive 6arriar is placed over open stutls spaced 24 inches on cerrter, maximum. The tnslda5on haarrl doscribad in Sectlon 2.2-3 is placed . . n 1 I!:w:aieJ anc~ [emporarily held in place with galvan¢ed staples or rooting nai;s. Vorlicui Wti joints must be staggered a minimum of orre stud st'a r. fron, edlacent courses and ocr.ur dirECYIy ov¢ :tuds. '":s nof}styr3n5 board and g8!'yE galvenized roofing nails with'f; Inch-diamet2r head or Na 16 gage gatvanized staples spaeuti 6 11101ea on ce;~tini wiii~ a .roinimll^• 1 j^Ch, i•;'%~~•at;pR S:9P13S niuai haw d nlifii1iiuil" er,nvo wldth ofin<-,h ^ac,jpling is permiC:ed only in v.bod vry of 0 54 or grza:ar. Care must gr i betakento avoid overtlriving Fasteners. Tte lath is applied with t'/,-inch end and side laps. Applicatior to minimum No. 20 naoe nalvanized ate+c±I ahuHs. i5 Simf1Ar eXqqpt Ihat NO. 6 ' ~.,...-,r.m,,. ..o-...~ ,....~i «!:r rr,.^.:`t.^.:~, r..:::~ 'shCJI ol3ld SCfCWS waShers 0re i05tafietl a18 1(1(A1HFOf1 fN'1tHf RC(F.WS IS^I:51 penetrate studs 'l, inch minimum. Stec' ;t>U sp~ 's inrhas on csnter, maA!nWn. ..ii' ~ . . _ , . . :t 4 . ^ ~ n } ~ 1 q; . . _ , . . . . . _ _ . .;~d Outside wall comers and paraVet corners are coverud with 6Xtl8 f116I21 COff18f f810(OICEDI9nS w80P1CrE C{ n 1L. 1~ 1 l1h. a,l' i. q I.lJ11LJUUJUI . . . , Vs G.. . andtloors.buttingJ-trimmelaledyesmwa:LrwL!ikt n.-.E.s for hose Gibbs, elcclric:a{ paneh arld c(t.c.' ,:`;'iv ..r snbsfrate Eu(1- Cx:r, gzCVrH Sn ,e cfu+ou.i ur iasii:neia nwsi TYip <'.tjL7(Iqg 19;P.t3l1 applied 2S dBSCflbed I❑ Sectior. 2 .3.1. 2.3.2.2 Fome-CorBOard:TheFome-CorBoardisattached in accordance with Evaluation Report ER-3335 to wood framing spaced a mawmwn 16 inches on center followed oy P!,-inch by No. 17 qage woven lath IappeA 2 inches. The latii is securad through the fome-Cor Ooard lo the sluds with No. 16 gage staples, 1-inch crown of suffcieni length lo Denetrete studs 1 inch minlmum. The ptaster consists of a minimum't; inch-thick base coat, followed by a minimum '!q inch-thick fmish coat Por other details, see Section 2.3.1. Additional . installation reqwremants are as noted in Section 23.21 2.5.3 Application ovar Solfd Backing: 2,3.3.1 Fiberboard: Minimum 4zinch-thick fiberboard sheathing is installed directly owr wood studs spaced 24 inches on center mapmum. The fibeNoard is temporanly held in place with corrosion-resistant shaples or roofing neils. A weather-resistive barrier of Mo layers of Cxade D building paper is applied over the fiberboard prior to the lath. The lath is attached to studs through the sheathing with fasteners and spacings as tlesaibed forlnsulatlon board in Section 2.32 of this report or Table 23-II-8-1 of the UBG whichever is more restrictive. The sysiem may also be applied to minimum No. 20 gage (0.0396 inch thick) steel studs spaced 24 inches on centermaximum System application is simiiar to wood studs except No. 8 seif-tapping corrasor: resislant sheet metal saews with a 1'1,4nch-diameter, 0.055-inch-thick wrrosion- resistant steol washers secure the lath and sheathing. Screw penetration is 114 inch minimum beyond stud. All wafis must be braced in accordance with the UBC. Exposed sheathing edges are protected Wth screeds. Holes in the substrate surtace are caulketl antl tne coating applied as tlescribed in Section 2 3.1. 2.3.3.2 Gypsum Sbeathing: Mlnimum'/; inch-thidc, water- resislant core gypsum sheaihing is installed directly on wood studs in a manner similarto fiberboard. fie system may also be apptietl to No. 20 gage (0.0396 inch thick) steel studs. Gypsum sheathing is fastensd in acrordance v.i;h Table 25-G of the UBC. A weather•resisliHe barrier is required over the gypsum sheathing pnorto installatlon ofthe lath and coating a5 J?crr:,ioa i~ S . i•• o~ 9 Fp° r., a 1 . If15t1l8:1U'7 JVBfd T'3j CtiE J~..;!., ..~.2 [~alf iPS inr i> t hr. 23.13 Plywootl: Plywood is applied tlirectry to wootl or mininiam No ?o gage (0 0396 inch lhick) steel studs under cor.ditions as SP' ' rqwa ?g. iV n. I r 'k;, ~ fiberboard. 2.4 +?nc•hour FirerosisUve Assembty: 2.4.1 Interior Face: One layer ot inch-thick Type X gypsum wallboarcS, water-resistant backerpoard or v?neer base is applied para0el or at right angl6s ro the interior face of 2 by 4 vuod studs spacad 24 inches on canter mazimurn. ii:8'rvuliiv`v`d'.:? 2NarhnN w1h h" rnafpQ naiic 1" inrhoc long wich a'r,-i~cn-sie:r~.,.~ x~, c S1U45 backaJ with vnood hanu g~Wallboard jointsmust be taped r ,.,ti .'a~',c•xr *caCs. ;rcated with joint compound. 2.4.2 kzlir:k " Tvoe X waf tnu.r: w , . _ . . . °.r : . j y,iv;+nzed roohngnails t'!, mches long with l,a-inch or Y; hads at 4 inches on center et board edges i5 l18dP.d n tnn ;zrr! h 1 • . . WG :i::.:. . . wire (abric.lath andwail coating are thenapplied as descnbetl ir, Section 2.3.32 llec !O 0J 04:32p MGM Supply L:o t3L131'?8b-U14~; p Pago 3 of b ER-4842 2.5 Miacellanwous: 2.5.1 inspectlon Requiremants: 6uilding tlepartment inspac[ion ts requveci on tath instaiiatfon pnor to application of the coatirig as noted in Section 108.5.5 nt Mo UBC. 2.6.2 Control Join[s: Controi joints mu:t be installed as spedfied by ihe arohitect, designer, buiklerorextenorcoating manufadurer m that order. In the absiince of det3iis, conveMiOnal three-coat piasterirxg details must be used. 2.5.7 Curing: Moist autiny must be prov?7Pd }pr 24 hours after application by mis;ing or light spaying after the finish coat. 2.6.4 Soffits: The system may be applied ta saffits, provitled the wsting is applied over rretallaih complying Wth Table 25-6 ui the UBC in lieu of wre-taDnc Iath. Meta4 iath fastaning must comply with Table 25-0, excapt the IenGth must be inrreased by the thickness of any ,ubstrate n _ ;lt::i 1 . Nplio;1 IG ,.tSiS J:;OGat10l~S such as wintiows and oiher simila, ereas. S ili Aeptlis fi,nsY!es or less may have the coating and tath a;+niiR7 t!~ aR; Hrcv:Cud .nd.aa:ing lath. . . exceedinq 6 inchgs must have subs?retqs ?f so!id worxi nr plywood. The vukstrpta is fuetzned in aoror~la~r? a.-t!, T,h;•. 23-11-t3-1 of tF« UBC, over which a doi;bte !ayer af a li;e c,'oanng, SBClion 2.3.2 Ott1115 fBpOrt. :.6 Idontiticatiafi: Tha , _ . ..~L~ - - _ _ , „y ~ N2i`:i8aili3adu'tdiSGifP•cilii(:iciUfetAtltifv3lUdi'OfIfOpD(l iruiTtbei ([iZ-4$iQ2) iii~nl f(Y2I t..... IiiSii) V: bun: pVntYfial.t 3. Weght of packaged mix. 4 Storaye inst(uctions, S Ma~mum amount of rrater ffiat mav be addod ar..^. . . . .....d ;n fk'ermining actual dii~uunt Curiny ins:r~cGa~~, Pofpstyrene toarn fNastir, insulation bearr,s are ider.tified i.^. 1i;l:-c3 ev<iiua6on reW`cs :+ud,Goiidliy, titd UUaod d6nSity trlUSt b2 nWetl. 3.0 EVfDENCE SU6MITTED Data in accurdance with 1he ICBO ES Acceptance Crileria !or Cementitious EMenw Wall Coatings (AC11), dated September 2002, and a qualiry control manual. 4.0 FINDINGS Thal the Grey Couche Exterior Stucco System, doscribed lo thta report, complle8 with the 1987 Unfform 6uilding Code"" (UBC), subJect ro the following condltlona: 4.1 The material and mothvde ot instaliation camply wIm thle reportantl the manufacWrar'a Instructions. 4.2 InatelleUon ia by contractors approved 6y the manufaoturer. 4.3 The syste:r is ccrzfin:d to Type V COtF5ftv^ElLiF?, except that the syutam appiied to gypsum sheathing ov»r ateoi studs In accordance with Section 2.3.3.2, wiiii0uf fJdin pl8]t[C 1119Ulatiqn bEr.+2.:r.ay ~5 J::c4' in constr~wen„ - - - < ,ybuvirr Is rocogn7zed ae a one-hour Tlre• .»,o;,iy w7ti+a coiirplying with Section 2.4 . . :a `::T :voOd 6tUp9 In the fire-resl.ctivc aca~~,~~~ . ~~-„~~u • . . ratlo of 33, In accordance with Sectlon 2316 of the UBC. 4.6 The Interior of iha bufiding is separ,,ted fiffmt qtu foam pkstfc insulatiuri boar(l wit!: : i;:e: ci ; arr:; r ccmpiying wiiii uwiion 2e02 oF tha Ubc such as'/,- . gypsu;n walliwerd applied in iS V VI iIIR UBl.. 3.6 kn iri5iatliati'vtt cxt'd, ao >huwni in i"iyryute 3 i5 iuii at lI/C jODSilb iUf itw uri a::ti 'a .:Jpj u;v.i wiG, u~a builAina denartment. 4.7 -1 itg aOowaDla wintl IoaUS on the xystem wlth wall traminr cpaced 24 !r.ehe=_ on center maz?r.:;~n; 2^:.' "e-IRCh minlmum coating ct s{ucca io 29 pst, poeitivn and nggaUve. The ellvwable vAntl loatls *ih saii ireiii±ng apaced 16 inches on center maximum and '7,dnch minimum coating ot Grey Ccueha s.ucce is 32 {is(, ;iv3i.6ve anu nr_,^,asf.,n, This report Is subJect to re-examinatWn in two years. rar Si: t incn =25.a mm. FIGURE t rnMCalR.1un RannYE U('C ;U tJ:i U'I: sfi Q$An ri n4 i U i. r' ;1 _ 9 Lii-SF41 :9Y~wrFJK I ~ ! ~ ~ ~ ' 1'%20WWn ` l% Sb~i -~~~M01d0OW1~~-OlA~ ~ YN/1IPMW m,ew??e»v ~ F~p FWeBba Y I I i eV~xO~tl8a4 WMG~Md ~ p'Fp61Ylp ~ ~a A ~ Q~00 Shsrtlwd Famm 8aw osGtl Qa6to or pck Flesh4n p ' Wa~acm+n - 1' A M IYl Y1Y~ ~~~WIIB~111Y. ~MY110QW WY On T" ftrM a$:si:ityy !~~'S Z! 54eC ~ Mwoow~on~ ~ ~ ! f•WvI/w LNIIM . J . . i ' ~ iui4Yanistl L Omp~pnA~a~wy k M.irr~.wni" ir' w. . ; ww~a r.awa Comproaswn Flt-AMtd Fnms Bu(Mose Cortisn?quere Corr.er . . ~ 53: . ...,...v... Fif:l1RF+_LIVPII_;f: 1 1.IkTnR-' ^Tt nNI D M 1 `c 'C" .ou No « mM rwmen.a ma. wft am. ft 11 .Df_,. ..;5 .....37= Paq@ B Of B cR-"4i ww c.n ~w+c. wQ+ws Pl~Y~M!' ►1YII ~ 11' YonomiRM IlpOREMLPtl1.lJp ~ ~ III'~1 I ~ eow e.aYv l4 C~* Y** ~s Ld , iarg+---- ~ . . d w•rcwv~`~"••, +w~ ap wrro ze" [ti. ta+ly.wa D.rmro 'mawi frw.m Daub# Faaard Paraw '..61. 1 - 6 2.: . A'tC:dl= EJ4R Ym~wlm Uea~c t A BW[ veama/ 9acr w~. x iaoA.wn rzT!c>~w.. ~aeerzaux JTarn woaUPiMnp~M~UR~6 lNM fOtlu NHTh'OLqh wrir~,:r:r::y fili JTNn Tttrn Wftia+'~Ww a.+d~ wr t~ n:~itl M y~os ~n4+~ MuwuaO JTM1n i• Y M C1A, 44w FIGUlZE 3^.-?1'OIrLe I?t$FA! "1iT7Ci: CE?k7t,°,-- M J Engineers, Inc. 2383 WEST 23RD CIRCLE GOLDEN, COLORADO 80401 (303) 233-2268 January 3, 2004 Mr. Gayle Hector 22 Rangeview Drive Lakewood, CO 80215 18No940 ueld v ...~_pou.. i 1~~~~r a~ed 'idap fiuipling a6pia leayM suoiioadsul plaid ol ioafqng a3no~A ddd Re: General structural observation for the new roof truss installation And the second floor addition 22 Rangeview Drive Lakewood, Colorado To Whom It May Concem, I did on November 4, 2003 observe the construction of the above noted residence. The proposed new constntction will include a new second floor addition which will be approximately 47'-6" X 29'-0 and will be situated over the main body of the house not to include the master bedroom area. The entire existing roof will be removed and a new pitched roof using prefab trusses will be installed over both the second story addition and the old or existing first floor areas. I have checked the existing foundation for the new proposed loading. The oniy area that will require additional foorings will be at the four comers of the second floor footprint area. The exisUng foundation which is a 3'-0" tall frost wall are presently in good condition. The proposed addition will work fine because the existing flat roofjoist are 2 X 12's at 16" on center and will now become the second story floor joist with a floor redesign load of 50 psf instead of an existing roof design of 45 psf. It is this engineer's opinion that with the four new concrete pads 3'-6 X 3'-6 X 12" with 6-#4 bars each way bottom added to the existing foundation for the second floor loading the existing home can and will suppod the new additional loads. N ~ N 0 ~ n n • 0 ~ 0 ~ cr In~ ~ w ff k{ ~ ~ i E T ~ FF+~ysF $ 4 `vO X~ 4 ~ ~D • ~ M I.'..: ~r• - . . ' I.. ' . . I . 'i ' + ~ . ~ I ~t a E 4- ~ M ~ . • r E-° i . i= 4 ^ ~ a a ~N b A ~D a x ~ ~ ~ 0 ~ ~ ~ ~ ~ ~ ~ ~ O~ N J Oi z CD n ~ O ~ ~ tD ~ • fD ~ n N ~ d a~ O O NWO W¢ ~t n ~ . G~000 06 CD ~ ~ a oo-''o o ~ ~ c ~ Cu c• co ~ ~ . 4'4. ~ ~ ~ A ~ - aa va o va ~ C cv ~ [D CD ~ cn ~ ~ ^ ~ Ou CDr~ V~ ~ CD lI N ~ J ~ ia w N J W ~ s g zo C' & 9 e ~ ~ N A pp ~ ty W P I \ ~ A + \ ti ~ a _ ~m A w P W O W ~ a ~ Q ~ a b a o a w - ~ ~ U W ~ u a ti W a ' u b W a ~ 0 ~ ~ • , _ CD t✓t~h~ , + m ~ ~ W O W ~ F $ m s a~. = W W A ~s t~ m Ii S x ° ~ a p+• ~ . aa ~ ~c ~ i XN O ~ IO Q 200 A Service in garage (200 A.) 4T•7 7/4" 51/2'viwnbioE wdl -I1 I!2" 8 7/S" CL0581' ~24'-0 1/8" - V E'-10 3B" gpTH 3'-0 V4"0 -0- S3 s I ~ 2'-fl 1/S" 11 1J8" 28'-2 1/2" o 14'-1 3 BEDROOAf STUDY O Guard rdl laoed 4' fiom ~ 36" high ~bove k x) 4" ~ spscing between p c&e . 14'-! 1/4• 2x4 wall framing ~ D. 10 C 11 = 10'-9 7/8 65 " C. ~ C. 22•-4 3/~ " d 1/2"~ . ; 1'-7 t1/ - 81-0 IB" Existing Flat 2x12 rooFrSters spaxd 16"o.c. I I+emme floor joists tm new awkhuction. covered witfi 3/4"C-Si tmd carpetcd. Foundsaion; two 1f4 bma top aw 6 84 br drilled ina e~nstin~, in two places g„ 1 Z•-6, 25'- ~ r-i i 7 a^ 1 8'-2 3/ " IS'-10" ~ Hector residence 1~ ~ 0 P a s'•• q ~po ~n•~ J ~ CD ~ ~/r~ O lY \ I CD ~t ~ III II I~ N a e W A ~ a a N N N A A a a x ~ u u 0 t N w G a ~ u e~d i N A ~ a~ Q£N ay~ $ ~E a ° . o n r ~ J W A ~ ~ ~ W 18x40 steel I beam bering point 1'-4"1 1 1'-5 7/8" Stack 5 2x4 studs to form column at eac end of I beam--' Exterior walls 2x4 studs @ 16" o.c. Cut existing 2x12 roof rafters (flat) install new 2x12 rim joist. Use existing 3/4" decking for floor 1'-6" Existing foundation Hector residence W 18x46 I beam filled with 2x members glued an nailed. Install Simpson THA 218 with lOd nails filling ail holes @ each huss connection\ Pre,-drill I beam to rE camage bolts 24"o.c. and bolt I beam to 2X members. Install FHA strap to bottom of both trusses with TEKO nails @ on all trusses along the I beam. Install FHA strap on both sides of trusses to connect the two. Hector residence J. 1 H,yS P~GlS ~ o ~7y R \ IF _ Y bfK 10 V!' 1'O 10 W' Y 2 ; \ x ~ ~ ~ 0 ~ ~ ~ a c~ ~ ~ ~ ~ JUIJ-23-19J2 18:34 iizuri WrnVitKLiriL r-cuuwL rwr.i. iu ; Aemwis R. Howe% S.IiA, c.~JUlYl 1-. U i Fdexra Hector 23' R+ M: F t' .L i c l E Garaga 39' aAn AMP \ ~ 3 - ~ Pamily Room ~ . 40' 29' Dining ; ~ Bed ~ Sed iLaund ~ Kitchen s~ . / I Living ~ ~ i ` Clos ~ ~ Bath Ezai.~x y Room ~ sea x .75 Htkt ~ 29' - t- 34' 29' 39' 650 CSrnnt Street. Drnrcr, Coloredo 80203 (303) 831-1843 ~ GILLAN'S ENGINEERING, INC. ti12 Lakeside Lane • Suite 150 • Denver, CO 80212 ~ 303/480-0471 • FAX 303/480-0547 IMPROVEMENT LOCATION CERTIFICATE Address: RANGEVIE4! DR Borrower(s): IfECTOR Title search bV: COLORADO PIAl'IONAL TITLE Commitment no. : 12554 Leqal Description: Lot 3, Block 15. PARAMOUNT NEIGHTS PART 4, County of JEFFERSON. State of COLORADO. 2 reR 6dNe6E BAfE/YENT Evr. / $TORY BQ/!K NausE tt 22 ~;~•~/~rr 9?Sy. 'Q4N~,V, 93.29' 4Av ~p~e, R =19a, 85-' sceLCC! zat N ~ N r~ ~ ~ ~o I Il is Iiere6y cetlificd 11ia1 tlie above descri6ed prnperty 15 NOT locmed willun a 100 yeu Iloal hazard baunJary in acc«dance willi the c,u{rtent IIUU I~eJcral AJmin. Ilowd Ilazsrd BumJary maps. ~ MapUalul 2 / /'N/()(7 ,MapNo. r ~PJ')079 Q,nn:] P Zone On tlie basis o( my knowledgc, in(ormation anJ belief I Lereby certity tlsat Ihis improvwnenl localion cettificale was prepared for COMMERCIAL FEDERAL MORTGAGE CORP. ANU COLORADO NATIbNAL fITLE undcr my supervisiun and Utal il is wt a LanJ Survey Plm or linpmvement Snrvey Plai, anJ ILm it is mt l0 6c reliwl upon fa the eslablislunenl of fenuw, builJing, a oiher future improvement lines. 1 futiher cettify lLet the improvemeuts an die above desctilxJ parcel on Jhis date, excepl utilily conneLtimtc anJ fenws anJ landscaping, are enlirely wilLin ILe bounJeries of die parcel, excepl as shown, Wal lLere ere no enaoachmenL¢ upon Ilw descLiLed prenuses by impwvemenls on nny adjuining [remises, except u inJicnleJ, anJ ILa11Lere is no apparent evidence or sign of any euemeol crossing w burdeuing any {urt of said parcel, except u mle. "Nofice: AccorJing iu Colurado Law you must commence any legal aclion based upon auy de(cct in diis survey wiUiin tluee years aflee you firsl discover sudi deten. ln m eveui, may any ar.lion baseJ upon any de(ect in this survey be commencal moce Ihan ten yeats Imm Ihe Jale of We certi(icaiion sLown hereon." a, ~ i G"• ~ Job No.: 1958-92 R vt. , Fee: $75.00 7-y.(3' CENSUS TRACT NO.: 105.04