HomeMy WebLinkAbout4621 Pierce StreetAMERICAN VETERAN ENVIRONMENTAL OCRFCTnc, LIMITED INSPECTION REPORT 4621 Pierce Street -0 0Q Z Wheatridge, CO `v r Inspection Date: 10/5/20 Report Date: 10/8/20 Report revised 4/25/21 Prepared for: Keith Schmelzer Inspected / Prepared by: Sam Rolf Asbestos Building Inspector - #921 American Veteran Environmental LLC P.O. Box 600 Bennett, CO 80102 303.901.9835 INTRODUCTION As requested, on October 5, 2020 American Veteran Environmental, performed a limited asbestos inspection at 4621 Pierce Street in Wheat Ridge, CO. The purpose of the limited inspection was to inspect and sample suspect asbestos containing materials prior to the planned renovation. The Environmental Protection Agency (EPA) and Colorado Department of Public Health and Environment (CDPHE) Air Quality Control Commission requires suspect Asbestos -Containing Materials (ACM) to be properly sampled and analyzed prior to any renovation or demolition activities. The NESHAP (National Emission Standard for Hazardous Air Pollutants) rule requires that suspect regulated asbestos -containing building materials be identified, classified and quantified prior to renovation or demolition activities. The CDPHE is responsible for administering the U.S. EPA NESHAP program for Colorado. INSPECTION Samples of suspect asbestos containing materials that would be impacted as part of this project were collected and submitted under chain of custody procedures to an accredited laboratory under the National Voluntary Laboratory Accreditation Program for analysis by Polarized Light Microscopy (PLM) with dispersion staining techniques per EPA methodology (40 CFR 763, Subpart F). Microscopic visual estimation was used in obtaining the percentage of asbestos in bulk samples. Laboratory Results are located in Appendix C at the end of this report. A physical assessment of homogenous areas of suspect ACM was conducted to assess the friability and condition of the materials. The EPA defines a friable material as a material, which can be crumbled, pulverized or reduced to powder by hand pressure, when dry. Friability was assessed by physically touching suspect materials. Based on the visual assessment, and the demolition plans for the building, bulk samples of suspect ACM were collected in general conformance with Asbestos Hazard Emergency Response Act (AHERA) 40 CFR763.86 protocols and as outlined in Colorado Department of Public Health and Environment (CDPHE) Regulation No. 8 Part B -Asbestos. In some circumstances a material that seems to be homogenous may yield conflicting laboratory results, in which case a return trip to identify and verify actual homogenous sampling areas may be necessary. The EPA and Colorado Department of Public Health and Environment require that a specific number of samples be collected for each homogenous area as follows: American Veteran Environmental LLC P.O. Box 600 Bennett, CO 80102 303.901.9835 Thermal Systems Insulation Surfacing Materials Up to 1,000 Sq. Ft. 3 Samples Up to 1,000 Sq. Ft. 3 Samples 1,000 — 5,000 Sq. Ft. 5 Samples 1,000— 5,000 Sq. Ft. 5 Samples More Than 5,000 Sq. Ft. 7 Samples More Than 5,000 Sq. Ft. 7 Samples Miscellaneous Materials: minimum of 2 each material, inspector's discretion REGULATORY REVIEW The EPA and The State of Colorado (CDPHE) regulate all materials containing greater than 1% asbestos. OSHA regulates materials containing any quantity of asbestos, even trace amounts. Both the EPA and CDPHE requires that an asbestos inspection be conducted by an AHERA accredited Asbestos Building Inspector certified by the State of Colorado prior to renovation or demolition regardless of the date of construction. If an accredited architect or engineer responsible for the construction of the subject building provides a written statement that asbestos containing materials were not used during construction an asbestos inspection is not required. The EPA National Emissions Standard for Hazardous Air Pollutants (NESHAP) regulation requires that ACMs be identified prior to renovation and demolition activities. NESHAP requires that no friable ACMs be disturbed during these construction activities: removal, encapsulation, or enclosure. The asbestos NESHAP rule (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. It also requires the identification and classification of existing building materials prior to renovation and demolition activities. Under NESHAP, asbestos containing building materials are classified as either Friable; Category I non friable; or Category 0 non friable ACM. Friable asbestos -containing materials are any material containing greater than one percent asbestos and that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Some friable materials, such as surfacing material; plaster; drywall, etc. may be in a non friable state but have the potential to become friable under mechanical means such as renovation and or demolition. ■ Category I non -friable ACM includes gaskets, packings, resilient floor coverings, and asphalt roofing products containing greater than one percent asbestos. ■ Category 11 non -friable ACM are any materials other than Category I materials that contain greater than one percent asbestos. American Veteran Environmental LLC P.O. Box 600 Bennett, CO 80101 303.901.9835 TRIGGER LEVELS Trigger levels pertains to the amount of asbestos or suspect asbestos containing material that has either been disturbed or will be disturbed through renovation or demolition activities. Trigger levels are categorized by the following two (2) building types: Single Family Residential Dwelling (SFRD) and Public or Commercial Buildings. Trigger levels are what regulates an asbestos action such as an inspection; abatement (removal, encapsulation; enclosure; repair); a spill response action; and permitting. • Single Family Residential Dwelling - asbestos trigger level is 32 square feet, 50 linear feet on pipes, or the equivalence of one 55 -gallon drum. • Public or Commercial Bldg. - asbestos trigger level is 160 square feet, 260 linear feet on pipes, or the equivalence of one 55- gallon drum. Regulation No. 8 Part B -Asbestos requires an asbestos inspection following the AHERA protocol be conducted prior to renovation and or demolition if the activities could disturb greater than the trigger levels of any asbestos or suspect asbestos containing material. TRACE ASBESTOS MATERIALS Non -Friable materials containing 1% or less asbestos also referred to as "trace asbestos" are not subject to EPA and CDPHE requirements. However, CDPHE requires Point Count analysis for materials reporting trace -1% asbestos. POINT COUNT Point counting is a more detailed means of analysis than standard PLM. Federal and State agencies define ACM as materials containing greater than one percent (1%) asbestos. The NESHAP regulation requires that if standard PLM analysis determines that a sample contains less than ten percent (10%) asbestos, the material must be considered asbestos containing or be point counted. Even if the sample is less than one percent (1%) by standard PLM, the material must be assumed to be ACM or point counted. If the point counting analysis is different than the PLM analysis, the point counting result takes precedence. If standard PLM analysis determines that a material has no asbestos or that the material contains greater than 10% asbestos, point counting is not necessary. American Veteran Environmental GLC P.O. Box 600 Bennett, CO 80102 303.901.9835 OSHA REGULATIONS FOR ASBESTOS The October 11, 1994, revision to the OSHA Standard requires that suspect ACM in buildings built prior to 1981 be assumed to be asbestos or an inspection be conducted by an EPA accredited asbestos building inspector. The Occupational Safety and Health Administration (OSHA) Asbestos Standard for the Construction Industry (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard requires that employee exposure to airborne asbestos fibers be maintained below the Permissible Exposure Limit (PEL) of 0.1 fibers per cubic centimeter (0.1f/cc). Personal air monitoring may be required if the workers are expected to be exposed to asbestos in excess concentrations of the PEL. OSHA regulations also require adequate training for all persons handling asbestos containing materials. The OSHA standard classifies construction and maintenance activities which could disturb ACM, and specifies training, work practices and precautions which employers must follow when engaging in each class of regulated work. States which administer their own Federally approved state OSHA programs, may require other precautions. EPA and CDPHE policy for the handling of joint compound that has been identified as ACM, when associated with drywall that is not asbestos, results in a mixed classification which requires an evaluation of work methods to determine if the impact will be direct or indirect to determine which classification applies. The following regulatory rationale is used to determine the final classification and when the composite result may be used, and when only the layer result can be used: EPA and CDPHE allows a composite sample result (drywall and joint compound together) to be used when renovation or demolition operations will only indirectly impact the joint compound, such as removal of the entire wall system (drywall and joint compound removed together), to determine if the material is ACM. This option does not prevent classifying the material as ACM based solely on the layered result as described below. 2. When the renovation or demolition operations will directly impact the joint compound, such as sanding or scraping the joint compound, then only the layer result for the joint compound may be used to determine if the material is ACM. American [veteran Environmental LLC P.O. Box 600 Bennett, CO 80102 303.901.9835 OSHA does not recognize the EPA and CDPHE composite analysis policy, and therefore asbestos containing joint compound is considered ACM regardless if the activity is direct or indirect impact and is subject to applicable OSHA asbestos regulations. Removal of the drywall and joint compound together under normal demolition methods is not considered direct impact to the joint compound and is not subject to EPA and CDPHE regulations when the composite result is less than 1% asbestos. RESULTS AND RECOMMENDATIONS Composite Results for Drywall and joint compound — Composite results as reported by the accredited laboratory identified the joint compound to contain less than 1% asbestos (<1%). Therefore, these materials are not regulated by the EPA or CDPHE. A composite result is reported by the laboratoryfor drywall samples only and based on the entire drywall system i.e., gypsum rock; paper; joint compound; texture; and paint. Taking the entire system as a whole the percentage of asbestos present in the sample is determined by the laboratory using the composite analysis method. The drywall samples collected and analyzed by PLM and composite analysis as part of this inspection were identified as having <1% (0.2%) asbestos and therefore is not considered an asbestos containing material. Certified Individuals - These materials are, however, regulated by OSHA which means that contract individuals hired for renovation purposes must be certified and trained in the required AHERA asbestos disciplines to remove, handle, and dispose of the materials if such plans will impact the materials. However, Final Clearance Air Sampling is not required Homeowner- In the event a homeowner performs the work, and the home is or plans to be their primary place of residence, the OSHA regulations for asbestos as outlined above DO NOT APPLY. Final Clearance Air Sampling is also not required. Waste Stream- Since the materials have been reported as containing less than 1% asbestos by composite method, these materials are not considered asbestos containing materials and can be disposed of as general construction debris. American Veteran Environmental LLC P.O. Box 600 Bennett, CO 80102 303.901.9835 � ► � i City of Wheat Ridge Homeowner Interior Remodel PERMIT - 202100185 PERMIT NO: 202100185 ISSUED: 02/11/2021 JOB ADDRESS: 4621 Pierce St EXPIRES: 02/11/2022 JOB DESCRIPTION: Interior remodel of kitchen and two bathrooms, work other areas including hall, bedrooms, living, and dining room limited to paint and floor refinishing - 1,367 sq ft total *** CONTACTS *** OWNER ( 315) 777-0469 S CHME L Z E R KEITH *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 107,715.00 FEES Total Valuation 0.00 Plan Review Fee 769.37 Use Tax 21262.02 Permit Fee 11183.65 ** TOTAL ** 41215.04 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. I, the property owner, by my signature, attest that I currently reside at the project property, intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers. If professionals are hired, those contractors are licensed with the City of Wheat Ridge and are listed on the permit. NOTE: Consultations and inspections will only be performed with the homeowner of record present. All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. 1* � 4 41' City of Wheat Ridge Homeowner Interior Remodel PERMIT - 202100185 PERMIT NO: 202100185 ISSUED: JOB ADDRESS: 4621 Pierce St EXPIRES: JOB DESCRIPTION: Interior remodel of kitchen and two bathrooms, work hall, bedrooms, living, and dining room limited to refinishing - 1,367 sq ft total 02/11/2021 02/11/2022 other areas including paint and floor I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 02/11/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Interior Remodel Date: Thursday, 3anuary 28, 20213:51:38 PM Residential Interior Remodel This application is exclusively for Residential Interior Remodels and other scopes of work which do not have a specific form already available. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 4621 Pierce St Property Owner Name Keith Schmelzer Property Owner Phone 3157770469 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email keith.schmelzer@gmail.com Address Attach City of Wheat 21 0128 Electronic Payment Form.odf Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" APPLICANT INFORMATION Applicant Name Keith Schmelzer What is your role in the Property Owner project? Are you performing the No work yourself, live in the home and will be living in the home 1 year after completion? Contact Phone Number 315-777-0469 (enter WITH dashes, eg 303-123-4567) Contact Email Address keith.schmelzer@gmail.com for Plan Review Comments Retype Contractor keith.schmelzer@gmail.com Email Address DESCRIPTION OF WORK Detailed Scope of INTERIOR REMODEL OF KITCHEN, MASTER BATH, AND Work - In the space HALL BATH INCLUDING REPAIR OF EXISTING WATER below (not as an DAMAGE, REPLACEMENT OF ALL FINISHES, FIXTURES, attachment), Provide a AND APPLIANCES. ALL OTHER SPACES INCLUDING detailed description of BEDROOMS, HALLWAY, LIVING AND DINING WORK LIMITED work including TO PAINT AND FLOOR REFINISHING ONLY. ELECTRICAL mechanical, electrical, REPAIR INCLUDING CHANGING SERVICE PANEL FROM plumbing work 125A TO 200A, REPLACEMENT OF LOW VOLTAGE CONTROLS, REPLACEMENT OF UNGROUNDED occurring, RECEPTACLES. PLUMBING REPAIR INCLUDING ADDITION adding/removing walls, OF PRV, REPLACEMENT OF SHUTOFF VALVES, etc REPLACEMENT OF HOSE BIBBS, AND SEWER LINE REPAIR AS NECESSARY. EXTERIOR WORK LIMITED TO SEWER LINE REPAIR AND REPLACEMENT OF ONE WINDOW AS INDICATED PER PLAN. FUNCTION OF ALL ROOMS TO REMAIN UNCHANGED. OVERALL SQUARE FOOTAGE TO REMAIN UNCHANGED. I, the applicant, I have entered a detailed scope of work. understand my application will be rejected if I do not include a Detailed Scope of Work. Location of Work Interior remodel of kitchen and two bathrooms, work other areas including hall, bedrooms, living, and dining room limited to paint and floor refinishing. Square Footage Area of Work Being Performed Asbestos Report Upload letter size imil-YA 4621 Pierce St -Asbestos Reoort-Amended.odf documents here Construction Plans scanned on 11'x17" or larger Project Value (contract value or cost of ALL materials and labor) 21 0125 4621 Pierce St Permit Set Stamoed.odf iWAVA1.7 $107,715 Valuation is OK SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Permit I attest that everything stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Yes Yes Keith Schmelzer Yes Email not displaying correctly? View it in your browser. 1 City Of "Theat idglle COMMUNITy DEVELOPMENT -�'q SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Subcontractor's insurance and license must be ap to date prior to permit issuance. Project Address: g62t i iercE' Qr, Permit#: 4. \ General C ontractor: 1�nve�u.� Qct$ ConSFr^�c� jn Electrical Sub -Contractor Company Name: Eiec�r;- Phone#: 023- 062-7 State License #: t{ 2g Master #: ,XA l5 Wheat Ridge License #: O 1 111 (reculred field) (�14k-z-e -3- MJ7A e1- 0117%2021_ Sig ay uthorized Ageni Dafee Plumbing Sub -Contractor Company Name: D.C. PlumbingCo Phone#: 303-778-0536 State License #:-560 Master #: 176038 Wheat Ridge License#: 018206 Signature of Authorized Agent Mechanical Contractor Company Name:) t L])P 7//t"I' l ( {k - VU 11 �11 Wheat Ridge License #: /- 27-26621 Date 4 - Signature of Authorized Agent Date AMERICAN VETERAN ENVIRONMENTAL ASBESTOS LIMITED INSPECTION REPORT 4621 Pierce Street Wheatridge, CO .t Inspection Date: 10/5/20 Report Date: 10/8/20 Prepared for: Keith Schmelzer Inspected / Prepared by: Sam Rolf Asbestos Building Inspector - #921 No ACM over 1%. Abatement contarctor not required. RS American Veteran Environmental LLC 13373 HarbackRd Bennet4 CO 80102 /Denver Office: 7100 Broadway Suite 3A Denver, C080221 303.901.9835 /www.avenv.com City of Wheat Ridge Building Division �mPw Yprel a aaye INTRODUCTION As requested, on October 5, 2020 American Veteran Environmental, performed a limited asbestos inspection at 4621 Pierce Street in Wheat Ridge, CO. The purpose of the limited inspection was to inspect and sample suspect asbestos containing materials prior to the planned renovation. The Environmental Protection Agency (EPA) and Colorado Department of Public Health and Environment (CDPHE) Air Quality Control Commission requires suspect Asbestos -Containing Materials (ACM) to be properly sampled and analyzed prior to any renovation or demolition activities. The NESHAP (National Emission Standard for Hazardous Air Pollutants) rule requires that suspect regulated asbestos -containing building materials be identified, classified and quantified prior to renovation or demolition activities. The CDPHE is responsible for administering the U.S. EPA NESHAP program for Colorado. INSPECTION Samples of suspect asbestos containing materials that would be impacted as part of this project were collected and submitted under chain of custody procedures to an accredited laboratory under the National Voluntary Laboratory Accreditation Program for analysis by Polarized Light Microscopy (PLM) with dispersion staining techniques per EPA methodology (40 CFR 763, Subpart F). Microscopic visual estimation was used in obtaining the percentage of asbestos in bulk samples. Laboratory Results are located in Appendix C at the end of this report. A physical assessment of homogenous areas of suspect ACM was conducted to assess the friability and condition of the materials. The EPA defines a friable material as a material, which can be crumbled, pulverized or reduced to powder by hand pressure, when dry. Friability was assessed by physically touching suspect materials. Based on the visual assessment, and the demolition plans for the building, bulk samples of suspect ACM were collected in general conformance with Asbestos Hazard Emergency Response Act (AHERA) 40 CFR763.86 protocols and as outlined in Colorado Department of Public Health and Environment (CDPHE) Regulation No. 8 Part B- Asbestos. In some circumstances a material that seems to be homogenous may yield conflicting laboratory results, in which case a return trip to identify and verify actual homogenous sampling areas may be necessary. The EPA and Colorado Department of Public Health and Environment require that a specific number of samples be collected for each homogenous area as follows: American Veteran Environmental LLC 7100 Broadway Suite 3A Denver, CO 80221 303.901.9835 /www.avenv.com City of Wheat Ridge Building Division Thermal Systems Insulation I Surfacing Materials Up to 1,000 Sq. Ft. 3 Samples Up to 1,000 Sq. Ft. 3 Samples 1,000 — 5,000 Sq. Ft. 5 Samples 1,000 — 5,000 Sq. Ft. 5 Samples More Than 5,000 Sq. Ft. 7 Samples More Than 5,000 Sq. Ft. 7 Samples Miscellaneous Materials: minimum of 2 each material, inspector's discretion REGULATORY REVIEW The EPA and The State of Colorado (CDPHE) regulate all materials containing greater than 1% asbestos. OSHA regulates materials containing any quantity of asbestos, even trace amounts. Both the EPA and CDPHE requires that an asbestos inspection be conducted by an AHERA accredited Asbestos Building Inspector certified by the State of Colorado prior to renovation or demolition regardless of the date of construction. If an accredited architect or engineer responsible for the construction of the subject building provides a written statement that asbestos containing materials were not used during construction an asbestos inspection is not required. The EPA National Emissions Standard for Hazardous Air Pollutants (NESHAP) regulation requires that ACMs be identified prior to renovation and demolition activities. NESHAP requires that no friable ACMs be disturbed during these construction activities: removal, encapsulation, orenclosure. The asbestos NESHAP rule (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. It also requires the identification and classification of existing building materials prior to renovation and demolition activities. Under NESHAP, asbestos containing building materials are classified as either Friable; Category l non friable; or Category 11 non friable ACM. • Friable asbestos -containing materials are any material containing greater than one percent asbestos and thatwhen dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Some friable materials, such as surfacing material; plaster; drywall, etc. may be in a non friable state but have the potential to become friable under mechanical means such as renovation and or demolition. Category I non -friable ACM includes gaskets, packing's, resilient floor coverings, and asphalt roofing products containing greater than one percent asbestos. Category II non -friable ACM are any materials other than Category I materials that contain greater than one percent asbestos. American Veteran Environmental LLC 7100 Broadway Suite 3A Denver, CO 80221 303.901.9835 /www.avenv.com City of Wheat Ridge Building Division am Pw Y.p,el a en oaye 4�§ TRIGGER LEVELS Trigger levels pertains to the amount of asbestos or suspect asbestos containing material that has either been disturbed or will be disturbed through renovation or demolition activities. Trigger levels are categorized by the following two (2) building types: Single Family Residential Dwelling (SFRD) and Public or Commercial Buildings. Trigger levels are what regulates an asbestos action such as an inspection; abatement (removal, encapsulation; enclosure; repair); a spill response action; and permitting. • Single Family Residential Dwelling - asbestos trigger level is 32 square feet, 50 linear feet on pipes, or the equivalence of one 55 -gallon drum. • Public or Commercial Bldg. - asbestos trigger level is 160 square feet, 260 linear feet on pipes, or the equivalence of one 55 -gallon drum. Regulation No. 8 Part B -Asbestos requires an asbestos inspection following the AHERA protocol be conducted prior to renovation and or demolition if the activities could disturb greater than the trigger levels of any asbestos or suspect asbestos containing material. TRACE ASBESTOS MATERIALS Non -Friable materials containing 1% or less asbestos also referred to as "trace asbestos' are not subject to EPA and CDPHE requirements. However, CDPHE requires Point Count analysis for materials reporting trace -1% asbestos. POINT COUNT Point counting is a more detailed means of analysis than standard PLM. Federal and State agencies define ACM as materials containing greater than one percent (1%) asbestos. The NESHAP regulation requires that if standard PLM analysis determines that a sample contains less than ten percent (10%) asbestos, the material must be considered asbestos containing or be point counted. Even if the sample is less than one percent (1%) by standard PLM, the material must be assumed to be ACM or point counted. If the point counting analysis is different than the PLM analysis, the point counting result takes precedence. If standard PLM analysis determines that a material has no asbestos or that the material contains greater than 10% asbestos, point counting is not necessary. American Veteran Environmental LLC 7100 Broadway Suite 3A Denver, CO 80221 303.901.9835 /www.avenv.com City of Wheat Ridge Building Division �mPw Yprel a aaye OSHA REGULATIONS FOR ASBESTOS The October 11, 1994, revision to the OSHA Standard requires that suspect ACM in buildings built prior to 1981 be assumed to be asbestos or an inspection be conducted by an EPA accredited asbestos building inspector. The Occupational Safety and Health Administration (OSHA) Asbestos Standard for the Construction Industry (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard requires that employee exposure to airborne asbestos fibers be maintained below the Permissible Exposure Limit (PEL) of 0.1 fibers per cubic centimeter (0.1f/cc). Personal air monitoring may be required if the workers are expected to be exposed to asbestos in excess concentrations of the PEL. OSHA regulations also require adequate training for all persons handling asbestos containing materials. The OSHA standard classifies construction and maintenance activities which could disturb ACM, and specifies training, work practices and precautions which employers must follow when engaging in each class of regulated work. States which administer their own Federally approved state OSHA programs, may require other precautions. EPA and CDPHE policy for the handling of joint compound that has been identified as ACM, when associated with drywall that is not asbestos, results in a mixed classification which requires an evaluation of work methods to determine if the impact will be direct or indirect to determine which classification applies. The following regulatory rationale is used to determine the final classification and when the composite result may be used, and when only the layer result can be used: 1. EPA and CDPHE allows a composite sample result (drywall and joint compound together) to be used when renovation or demolition operations will only indirectly impact the joint compound, such as removal of the entire wall system (drywall and joint compound removed together), to determine if the material is ACM. This option does not prevent classifying the material as ACM based solely on the layered result as described below. 2. When the renovation or demolition operations will directly impact the joint compound, such as sanding or scraping the joint compound, then only the layer result for the joint compound may be used to determine if the material is ACM. American Veteran Environmental LLC 7100 Broadway Suite 3A Denver, CO 80221 303.901.9835 /www.avenv.com City of Wheat Ridge Building Division OSHA does not recognize the EPA and CDPHE composite analysis policy, and therefore asbestos containing joint compound is considered ACM regardless if the activity is direct or indirect impact and is subject to applicable OSHA asbestos regulations. Removal of the drywall and joint compound together under normal demolition methods is not considered direct impact to the joint compound and is not subject to EPA and CDPHE regulations when the composite result is less than 1% asbestos. RESULTSAND RECOMMENDATIONS • Composite Results for Drywall and joint compound —Composite results reported the joint compound to contain less than 1% asbestos. Therefore, these materials are not regulated by the EPA or CDPHE. • Certified Individuals - These materials are, however, regulated by OSHA which means that contract individuals must be certified and trained in the required AHERA asbestos disciplines to remove, handle, and dispose of the materials. • Waste Stream- Since the materials have been reported as containing less than 1% asbestos by point count method, these materials can be disposed of as general construction debris. LIMITATIONS AVENV only sampled as requested. This was a limited inspection and is not to be considered a comprehensive asbestos survey of this address. For any materials not listed in this report that maybe subject to renovation or demolition, please contact AVENV for additional sampling. Asper the Asbestos Hazard Emergency Response Act (AHERA), a suspect material is considered asbestos -containing unless it is proven otherwise by sampling and analysis. GENERAL COMMENTS American Veteran Environmental, LLC assumes no liability for any loss, injury, and or claim for damages arising directly or indirectly from any use or reliance on this report or the opinions expressed herein. American Veteran Environmental LLC 7100 Broadway Suite 3A Denver, CO 80221 303.901.9835 /www.avenv.com City of Wheat Ridge Building Division am Pw Y.p,el a en oaye 4�§ This report was prepared by American Veteran Environmental, LLC (AVENV) at the request of and for the sole benefit of the client. The material in this report reflects the best judgment of AVENV, considering the information that was available at the time of preparation. This limited inspection was performed using regulatory procedures and a level of diligence exercised by professional consultants performing similar services. Should you have any questions concerning this project, please do not hesitate to contact our office at (303) 901-9835. Thank you for the opportunity to provide this service to you. Respectfully Submitted, Sam Rolf, #921 Asbestos Building Inspector American Veteran Environmental LLC 7100 Broadway Suite 3A Denver, CO 80221 303.901.9835 /www.avenv.com City of Wheat Ridge Building Division A� Appendix A Homogenous Materials Table American Veteran Environmental LLC 7100 Broadway Suite 3A Denver, CO 80221 303.901.9835 /www.avenv.com City of Wheat Ridge Building Division TABLE 1 HOMOGENEOUS MATERIALS TABLE 4621 Pierce Street Wheat Ridge, Colorado Friable Hazard Ranking Estimated HA Description Locations Non -Friable & Disturbance Quantity Category Potential Composite drywall w/ joint <1,000 sf Living room - ceiling Friable N/A CDW01 compound Misc. Composite drywall w/ joint <1,000 sf Bathroom/kitchen - walls/ceilings Friable N/A CDW02 compound Misc. Ceiling tile with brown glue dot <1,000 sf Dining room ceiling Friable N/A CT01 adhesive Misc. Sheet vinyl flooring- floral block <1,000 sf kitchen Friable N/A KSV1 pattern Misc. Mastic/adhesive associated with <1,000 sf Kitchen and bathroom Friable N/A KMA01 4" brown baseboard Misc. Acoustic texture on drywall <1,000 sf living room and adjoin hallway Friable N/A TS01 painted white ceilings Surfacing Painted drywall- no texture <1,000 sf Kitchen walls/ceiling Friable N/A TS02 Bathroom walls/ceiling Surfacing Backing material associated with <1,000 sf Friable N/A SV01 sheet vinyl bathroom Misc. N/A =Not applicable Asbestos Containing Materials are Listed in Red. Materials Containing 1% or less are Listed in Blue. City of Wheat Ridge Building Division Friable: material that be crumbled pulverized or reduced to powder with hand pressure when dry Non -Friable: material that cannot be crumbled pulverized or reduced to powder with hand pressure when dry Thermal Systems Insulation (TSI): used to control heat transfer and or condensation on HVAC, hot and cold water or other mechanical systems etc. Surfacing Material: material that is sprayed or troweled onto surfaces such as fire proofing on structural members, plasterfor acoustical, decorative, etc. Miscellaneous Material: all other materials including taping mud floor file mastic, stucco, leveling compound and hard plasters Category I non friable ACM: resilientfloor coverings, asphalt roofing products, packings, gaskets, or caulking containing greater than 1% asbestos Category 11 non -friable ACM: any material that is not Categoryl that contains greater than 1% asbestos Hazard Ranking: 1= damaged or significantly damaged Thermal Systems Insulation (TSI) ACM; 2=damaged fnjable surfacingACM; 3—significantly damaged fnable surfacing ACM; 4—damaged or significantly damaged fnjable miscellaneous ACM; 5 ACBM with potential for damage; 6ACBM with potential for significant damage; 7—any remaining fnable ACBM or suspected ACBM. Disturbance Potential: Low = the material may be accessible but is not likely to be damaged under most circumstances. Moderate = the material is accessible and is likely to suffer limited damage over time. High = the material is fnjable and/or already damaged is accessible, and there is specific reason to believe the material will receive a large amount ofdamage in the foreseeable future. Condition: Good = the material had no visible damage, or extremely minor damage or surface marring (i.e., a room of floor file has only four orfive with small corners broken from the tile. Damaged = the material had visible damage evenly distributed over less than 10% ofits surface or localized over less than 25% of its surface. Significantly damaged = the material had visible damage that is evenly distributed over 10% or more of its surface or localized over 25% or more or its surface. Asbestos Containing Materials are Listed in Red. Materials Containing 1% or less are Listed in Blue. City of Wheat Ridge Building Division A� Appendix B Bulk Sample Summary American Veteran Environmental LLC 7100 Broadway Suite 3A Denver, CO 80221 303.901.9835 /www.avenv.com City of Wheat Ridge Building Division APPENDIX B. Asbestos Bulk Sample Log Project Name: 4621 Pierce St Project Address: 4621 Pierce St. Wheat Ridge, CO Contact / Client. Keith Schmelzer 315-777-0469 Inspection date & Lab COC # 10/5/20 I CEI B207749 Building: SFRD- kitchen / bath remodel Work Area: Interior Asbestos: Yes Accessibility unoccupied To Building Occupants? Sample Description of Material Hazard AHERA Asbestos Sample location No. Sampled Ranking Rating Laboratory Results CDWO1 Composite drywall w/joint 6 -Good Friable <1% Hall bathroom wall at mirror -1 compound Condition Misc. Chrysotile CDWO1 Composite drywall w/joint None Hall bathroom corner behind -2 compound N/A N/A detected door CDW02 Composite drywall w/joint 6 -good Friable <1% Master bathroom wall, west -1 compound condition Misc. Chrysotile corner CDW02 Composite drywall w/joint 6 -good Friable <1% Master bathroom wall NW -1 compound condition Misc. Chrysotile corner Ceiling the w/ brown glued None Dining room ceiling near CT01-1 dot adhesive N/A N/A detected fireplace 12x12 Ceiling the w/ brown None Dining room above doorway CT01-2 glued dot adhesive N/A N/A detected Sheet vinyl flooring -floral None Kitchen at doorway KSVI-1 block pattern N/A N/A detected Sheet vinyl flooring -floral None Kitchen center KSVI-2 block pattern N/A N/A detected 4° brown baseboard None Kitchen KMA1-1 adhesive N/A N/A detected 4° brown baseboard None kitchen KMA1-2 adhesive N/A N/A detected Fibrous backing material None Kitchen SVO1-1 associated w/ sheet vinyl N/A N/A detected Fibrous backing material None Kitchen SVO1-2 associated w/ sheet vinyl N/A N/A detected Acoustic texture on drywall None Living room ceiling, east side TS01-1 painted white N/A N/A detected Acoustic texture on drywall None Living room ceiling, center TS01-2 painted white N/A N/A detected Acoustic texture on drywall None Living room ceiling west side TS01-3 painted white N/A N/A detected City of Wheat Ridge Building Division Sample Description of Material Hazard AHERA Asbestos Sample location No. Sampled Ranking Rating Laboratory Results Painted drywall- no texture None Kitchen west wall TS02-1 N/A N/A detected Painted drywall -no texture None Kitchen ceiling center TS02-2 N/A N/A detected Painted drywall -no texture None Kitchen east wall TS02-3 N/A N/A detected City of Wheat Ridge Building Division A� Appendix C Laboratory Results American Veteran Environmental LLC City of 7100 Broadway Suite 3A Denver, CO 80221 303.901.9835/www.avenv.com Wheat Ridge Building Division 0 eurofins CEI October 12 2020 American Veteran Environmental TO 13373 N Hancock Rd Benneft CO 80102 CLIENT PROJECT 4621 Pierce St CEI LAB CODE 3207749v2 October hThe ampler were renaor Puce Esoo metphon e analysed for asbestos using operating light microscopy CuA) per the PA Sample results ls VACMs) per EPA regulatory requirements mt The notation limit for the EPA eoo Aended asbestos are considered asbestioscontaiding ase<tam asbestos by weight as determined by visual eatimauon anode Bar PhD Clud aboratiory Director NTESTING VLA� Solari Dal 730 SE Maynard Road -Cary PC 27511 - 919 481 1413 "mervoeo tik eu rof ins I CEI ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Purl for American Veteran Environmental, LLC I'll, ofinS c[i AMENDED AsbesttossRRXport Summary PROJECT 4621 Pierce St LAB CODE BM774M METHOD EPA60OfR93fII6andEF)A6OOfNR82fO20 AGOG OS Client ID Lecor Lab ID Color Sample Descriphon Car B122930B Brawn Glue Gone Debobd Chreaffe L% B122931 B Brawn Glue Gone Debobd GOOGOL 1 B122937 obbe Call Growl Garrard Chreaffe L% More 1 B122942 obbe Call Growl Garrard Chreaffe L% More 2 B1229C obbe Call Growl Garrard Chreaffe L% svi 3122944 Brawn Backing KaPonal Gone Debobd retool 1 B12290A Brawn el Gone Debobd tik Lau Yofinsc[i rvrervoeo ASBESTOSRBULK ANALYSIS CLOSE: Armencan Vereran Environmental LLC Lab Coldem 32077491 13373 N manace Rd DaPoRecravered 10 06 20 Ofieurd IN Bel CO 80102 DartleArNaBlandered: 10 06 20 GA S BEST AS COMPONENTS nateReprearded: 10 06 20 Propect 4621 Pierce dc Descaphon Aftribles ASBESTOS BULK GEN. EPA 600 METHOD Ofieurd IN ON ON NO GA S BEST AS COMPONENTS ASBESTOS ON IN Descaphon Aftribles Ri Non Serene AS CT01 1 Call Hotel 95% Rinloode 5% palm None Dedecred B122930A came Been Remus Losely Bound B122930B Glue ON To lenders 2% Rinloode 60% Binder None Dedecred Been 38% CNIC Com Remus Bound B122931A came Been Remus Losely Bound B122931B Glue ON To lenders 2% Rinloode 60% Binder None Dedecred Been 38% CNIC Com Remus Bound B122932 ft te 15% Binder Remus 10% Foam Bound B122933 ft te 15% Binder Remus 10% Foam Bound B122934 ft te 15% Binder Remus 10% Foam Bound our AT General Diane Suldniff churl tik Lau Yofinsc[i rvrervoeo ASBESTOSRBULK ANALYSIS Client Arnencan Vereran Envirennandal LLC Lab Coll 32077491 13373 N marbace Rd DateRecravered 10 06 20 ON Bel CO 80102 DartleArnallandered: 10 06 20 ASBESTOS nateReprearted: 10 06 20 Propect 4621 Pierce dc Non Redone AS ASBESTOS BULK FEEL EPA 600 METHOD Ofieurd ID ON ON NO NA S BEST AS COMPONENTS ASBESTOS ON ID Desonoon Aftribles Ri Non Redone AS POP 1 Shem ALB Hotel 25% CNISIodde 50% ALB None �d B122935A Off White 25% Binder Ri Bound B122935B No No ON To lenders 2% CNISIodde 60% No No None Dedeacted Tan 38% Colo Com Ri Bound POP 2 Shem ALB Hotel 25% CNISIodde 50% ALB None Dedeacted B122936A Off White 25% Binder Ri Bound B122936B No No ON To lenders 2% CNISIodde 60% No No None Dedeacted Tan 38% Colo Com Ri Bound B122937 Ad TO ound Paul Crearn 10% Binder Ri 65% Owl Bound red UPS 2% ChOgme tund in Tom Compound Simple Neurone 10% Tom Compound winni occurs 0 2% Cl deal B122938 ft te 88% Owl Ri Bound red UPS No Jora Compound present just a Emewall wl Palm tik Lau Yofinsc[i rvrervoeo ASBESTOSRBULK ANALYSIS CLOSE: Arnencan Vereran Environmental LLC Lab Coll 32077491 Ofieurd IN ON ON 13373 N manace Rd DaPoRecravered 10 06 20 ON IN Desonoon Aftribles Earned CO 80102 DartleArNaBlandered: 10 06 20 10% Rinloode 2% palm nateReprearded: 10 06 20 Propect 4621 Pierce dc Ri ASBESTOS BULK FEEL EPA 600 METHOD Ofieurd IN ON ON NO NA S BEST AS COMPONENTS ASBESTOS ON IN Desonoon Aftribles Ri Non Serene AS TSAR 1 Erywall Hotel 10% Rinloode 2% palm None �d B122939 came 88% Owl Ri Bound red UPS No Rome credit Just a Erywall WE Palm TSAR 2 Erywall Hotel 10% Rinloode 2% palm None Molecular B1229Q came 88% Owl Ri Bound red UPS No Rome credit Jul Erywall WIP31M TSAR 3 Erywall Hotel 10% Rinloode 2% palm None Molecular B122941 came 88% Owl Ri Bound red UPS No Rome credit Just a Erywall WE Palm ABEAM 1 Erywalldom Hotel 10% Rinloode 15% Colocat <1% Cl B122942 Compound came Crearn 10% Binder Ri 65% Owl Bound red UPS 2% ChOgere tund in Tom Compound Simple Perdue 10% Tom Compound Puri occurs 0 2% Cl deal ABEAM 2 Erywalldom Hotel 10% Rinloode 15% Colo Com <1 % Cl B1229C Compound came Crearn 10% Binder Ri 65% Owl Bound red UPS 2% ChOgere tund in Tom Compound Simple Perdue 10% Tom Compound Puri occurs 0 2% Cl deal tik Lau Yofinsc[i rvrervoeo ASBESTOSRBULK ANALYSIS Client Arnencan Vereran Environmental LLC Lab COOKE 32077491 13373 N Harback Rd DadeRecewed 10 06 20 ON Earned CO 80102 DareArNaBbeared: 10 06 20 ASBESTOS nateReproarded: 10 06 20 Pricubect 4621 Pierce dc ASBESTOS BULK FEEL EPA 600 METHOD Cleard IN ON ON NO NA S BEST AS COMPONENTS ASBESTOS Sv 1 Bidding MaNnal No To demons 100% Rinlood done �d B122944 Brown SETO Bound LEE SOON No Shei pni Puri Bidding madonal SV 2 Bidding MaNnal No To demons 100% Rinlood done DeNcled B122 M Brown SETO Bound LEE SOON No Shei pni Puri Bidding madonal B12290A Brown SETO Bound B12290B ON Ad No To demons 2% Rinlood 60% ON Ad done DeNcled Tan 38% CNIC Cort SETO Bound B122947A Brown SETO Bound B122947B ON Ad No To demons 2% Rinlood 60% ON Ad done DeNcled Tan 38% CNIC Cort SETO Bound W eurofins I CEI LEGEND Ni -NALACcessfiroff AnthophylIfte CacCad - calcium carbonate REPORTING LINT: A% by feel esfirsation REPORTING LINT FOR POINT COUNTS: 0 25% bi Ponsor 0 1% by 1 000 Points vinyl door tiles yen be dinclut to analysis via deduced Light microscopy FPLM) EPA recommendsthid all NOBst analysed by PLM and Found not to contain asbestos be further analysed by Transmission Election recroscopy, JEM) Please note thyd PLM endives of duck and per samples Ex asbestos is feel This repcom relates onlyto the pampas tested or analysed and may not be reproduced except in Pull Schout when appri by Fri CEI Fri CEI makes no warrarty representation regarding the accuracy of clent submitted information in preparing and presenting analytical results Interpretation ofthe analytical results is the belde responsibility ofthe bent Samples was reversed in acceptable condition unless otherpre noted This report may not be used by the clent to claim lA.Am�iona,ovded evaso.includes d�desaromeP a000..n LYST cOPRYLIFL Hvla�P InconedProjaaName ao9�a��®�E ,_ ASBESTOS CHAIN OF CUSTODY CEILA�BS LAB USE ONLY: 730 SE Maynard Road, Cary, NC 27511 CEI Lab Code: l y Tel: 866-481-1412; Fax: 919-481-1442 CEI Lab I.D. Range: I'; I,j„qi0 - (> 1�)rILJJ COMPANY INFORMATION PROD, T INFORMATION CEI CLIENT #: 28520 Sam Rolf Company: American Veteran Environmental, LLC 3039019835 Address: 13373 N. Harback Rd. rr Project Name: �Z io �� j Cf Ce' 7+• Bennett, CO 80102 Project ID#: Email: srolf@avenv.com;pbowers@avenv.com PO #: Tel: Fax: STATE SAMPLES COLLECTED IN: IF TAT IS NOT MARKED STANDARD 3 DAY TAT APPLIES. ASBESTOS METHOD 4 HR 8 HR TURN AROUND TIME 24,HR,1 2 DAY 3 DAY 5 DAY PLM BULK EPA 600 ❑ ❑ I I VI ❑ ❑ ❑ PLM POINT COUNT (400) EPA 600 DB �\L Zv �— c W& ❑ PLM POINT COUNT (1 000) EPA 600 ❑ ❑ ❑ ❑ ❑ ❑ PLM GRAY w POINT COUNT EPA 600 ❑ ❑ ❑ ❑ ❑ PLM BULK CARS 435 c._❑ ❑ ❑ ❑ ❑ PCMI AIR NIOSH 7400 U ❑ ❑ v ❑ ❑ TEM AIR EPA AHERA ❑ ❑ ❑ ❑ ❑ ❑ TEM AIR NIOSH 7402 ❑ ❑' ❑ ❑ ❑ ❑ TEM AIR ISO 10312 ❑ ❑ ❑ ❑ ❑ ❑ TEM AIR ASTM 6281-09 ',❑ ❑. ❑ ❑ ❑ ❑ TEM BULK CHATEIELD ❑ ❑ ❑ o ❑ TEM DUST WIPE ASTM D6480-05 ❑ ❑ ❑ ❑ ❑ ❑ TEM DUST MICROVAC ASTM D5755-09 ❑ ❑ ❑ ❑ ❑ ❑ TEM SOIL ASTM D7521-13 CINCINNATI METHOD w ��� ❑ ❑ ❑ ❑ TEM VERMICULITE ❑ ❑ ❑ ❑ OTHER: ❑ ❑ ❑ ❑ ❑ ❑ REMARKS /SPECIAL INSTRUCTIONS: Accept Samples Reject Samples RetInquished 8'. Date/Time r., Received B : DB �\L Zv �— c W& l i oti Samples will be disposed of 30 days after analysis Page ' of <it of Wheat Ridge Building Division Version: CCOC.06.16.1/2.LD Page 1 of 2 CE1L^E3S ��c -SZvs SAMPLING FORM p of -N q COMPANY CONTACT INFORMATION Company: Job Contact: Project Name: C1�1 -1 Project ID #: Tel: FIELD ID # SAMPLE LOCATION (SQ. H) VOLUME (LITRES) C1�1 -1 L—OI Z. 75v�-2 -r5al -3 sv1 WSJ i c D(AJO I 1 ►� d� /moi l GoLtiol - Z A Soz-I 15 z I .T -507---4— 50Z_3COwoZ-1 C OL -30 Z- M/3Ar-m c(3wog-z Jy\3(k11 ( jJ 1 -M !-3 PV IN 5j 2 V-mAo'L ✓ Wh :ity of !at Ridge 2I �� Building Division VERSION MCOC.0616.2/2.LM Mold COC Page 2 of 2 Bj6�-� �q Rouse, Nickolas From: Rouse, Nickolas Sent: Tuesday, October 06, 2020 11:56 AM To: 'srolf@avenv.com' Subject: Confirmation Hey Sam, Thanks for the help earlier! This is written confirmation of our discussion earlier on projects 4261 Pierce St. and 6699 W. Meixco. Per our phone call we will proceed as follows: 4261: We added the project name 4261 Pierce St to the COC. We also marked the project to be ran as a 24 Hr PLM Bulk 6699: We will mark the COC for a 24 Hr turnaround for PLM Bulk Please reply at your earliest convenience to confirm. Let me know if there is anything else I can do for you, and thank you for choosing Eurofins CEI Labs. Best Regards Nickolas Rouse Senior Laboratory Technician, Sample Receiving Eurofins CEI 730 SE Maynard Rd Cary, NC 27511 USA Phone: +1 919-481-1413 Fax: +1 919-481-1442 E-mail: Nickolas. RouseO-eurofinset.com www.EurofinsUS.com/CEI City of Wheat Ridge Building Division Coppens, Vanessa From: Paula Bowers <pbowers@avenv.com> Sent: Monday, October 12, 2020 8:28 AM To: CEI - Reception Subject: B207749 EXTERNAL EMAIL* Can you please change this report address to 4621 Pierce St Please. thank you!! Paula S. Bowers Industrial Hygienist Cell - 720.767.4897 Office 303.901.9835 email- pbowers ar,avenv.com website- www.avenv.com American veteran Environmental "Il'onest3T, Loyal4t, Responsibility, Integrity" * WARNING - EXTERNAL: This email originated from outside of Eurofins TestAmerica. Do not click any links or open any attachments unless you trust the sender and know that the content is safe! City of Wheat Ridge Building Division 4621 PIERCE STREET WHEAT RIDGE, CO 80033 Owner / Architect Keith Schmelzer 4621 Pierce Street Wheat Ridge, CO 80033 315.777.0469 keith.schmelzer@gmail.com Contractor Dovetail: Design & Construction Inc Bill Walter 2309 S Cherokee Street Denver, CO 80223 303.669.3935 bwaltden@aol.com PERMIT SET 112512021 SHEETINDEX Sheet f�Lmber Sheet Name W dGO 00 !COVER SHEETD '0511 DE Not TON P LAND2 01�At 01 !FLOOR PLAd LEGEND ❑ [NOT ISSUED ❑. ISSUED ❑° SSU ED FOR REFERENCE ONLY ® ISSUED WITH REVISIONS X❑ wIT DDRnwN W licatMRtdge APPROVED r Randy Slusser 2/04/2021 PIM, Enamne Oak Podded dean Ar Repoft tre No Longer oederd ON SITE PLANS MUST BE ON SITE FOR INSPECTION ALL Projects are Subject to Field Inspections W z W in U) W W W W N J W M 0 00 rNA r W 4T ARCHITECTURAL ABBREVIATIONS & AND DIM DIMENSION VICINITY MAP CMU REC RECESS(ED) @ AT DN DOWN LAB LABORATORY REFR REFRIGERATOR or REFRIGERATED RPM SEMI-RIGID INSULATION DS DOWNSPOUT LAM LAMINATE REINF REINFORCED ACT ACCOUSTICAL CEILING TILE DWG DRAWING LAV LAVATORY REQD REQUIRED AD AREA DRAIN LF LINEAR FEET REV REVISE, REVISED or REVISION ADJ ADJACENT (E) EXISTING LLH LONG LEG HORIZONTAL RF RESILIENT FLOORING AFF ABOVE FINISHED FLOOR EA EACH LLV LONG LEG VERTICAL RFG ROOFING AFS ACCESS FLOORING SYSTEM EF EXHAUST FAN LMC LINEAR METAL CEILING RO ROUGH OPENING AHU AIR HANDLING UNIT EJ EXPANSION JOINT LP LOW POINT RR RESTROOM ALT ALTERNATE ELEC ELECTRIC(AL) _ o - ALUM ALUMINUM ELEV ELEVATION MAX MAXIMUM SCHE SCHEDULE ANOD ANODIZED ENT ENTRANCE SYSTEMS MECH MECHANICAL D DEVICES AND WALL PLATES ATALL OTHER LOCATIONS TO BE WHITE. AP ACCESS PANEL EP EPDXY PAINT MEP MECHANICAL, ELECTRICAL AND PLUMBING SECT SECTION APC ACOUSTICAL PANEL CEILING EQ EQUAL MEZZ MEZZANINE SF SQUARE FEET; STONE FACING ARCH ARCHITECTURAL EQUIP EQUIPMENT MF MASONRY FLOORING SHTG SHEATHING ASI ARCHITECT'S SUPPLEMENTAL EWC ELECTRIC WATER COOLER MFR MANUFACTURER SIM SIMILAR INSTRUCTIONS EWS EXTERIOR WALL SYSTEM MIN MINIMUM SOG SLAB ON GRADE ASPH ASPHALT EXP EXPOSED MISC MISCELLANEOUS SPEC SPECIFICATION(S) AT ACOUSTICAL TREATMENT EXT EXTERIOR MO MASONRYOPENING SQ SQUARE AWC ACOUSTICAL WOOD CEILING I MR MIRROR SS STAINLESS STEEL FACP FIRE ALARM CONTROL PANEL MTD MOUNTED) ST STONE B BASE FAF FLUID APPLIED FLOORING MTL METAL STC SOUND TRANSMISSION CLASS BA BATH ACCESSORY FBO FU RNISHED BY OWNER MULL MULLION STD STANDARD BIT BITUMINOUS FCU FAN COIL UNIT wmmry w4an vi STG STORAGE BE BORROWED LIGHT FD FLOOR DRAIN NA NOT APPLICABLE STL STEEL BLDG BUILDING FDN FOUNDATION NIC NOT IN CONTRACT STN STONE SLAB BLKG BLOCKING FE FIRE EXTINGUISHER NO NUMBER STRU STRUCTURE or STRUCTURAL BM BEAM FEC FIRE EXTINGUISHER CABINET NOM NOMINAL CT BO BOTTOM OFSUSP FF FINISH FLOOR NTS NOT TO SCALE SUSPEND(ED) BOT BOTTOM FH FIRE HYDRANT SYS SYSTEM BR BRICK FHC FIRE HOSE CABINET OA OUTSIDE AIR BRG BEARING FIXT FIXTURE OC ON CENTER T TREAD; TILE BTWN BETWEEN FO FACE OF OD OUTSIDE DIAMETER T&G TONGUEAND GROOVE FRE FIBER REINFORCED LAMINATED OFCI OWNER FURNISHED, CONTRACTOR TA TOILETACCESSORY CATV CABLE TELEVISION FRP FIBERGLASS REINFORCED PANEL INSTALLED TEL TELEPHONE CB CEMENT BOARD FRT FIRE RETARDANT TREATED OFOI OWN ER FURNISHED, OWNER INSTALLED THR THRESHOLD CCD CONSTRUCTION CHANGE DIRECTIVE FT FEET OPNG OPENING TO TOP OF CCTV CLOSED CIRCUIT TELEVISION FTG FOOTING OPP OPPOSITE TOC TOP OF CONCRETE CG CORNER GUARD ORD OVERFLOW ROOF DRAIN TOS TOP OF STEEL CIP CAST IN PLACE GA GAUGE TOW TOP OF WALL CJ CONRTOL JOINT GALV GLAVANIZED PC PRECAST CONCRETE TR TRIM CL CENTERLINE GB GRABBAR PL PROPERTY LINE TYP TYPICAL CLG CEILING GC GENERAL CONTRACTOR PLAM PLASTIC LAMINATE TZ TERRAZZO CLR CLEAR GWB GYPSUM WALLBOARD PLBG PLUMBING CMU CLAYMASONRYUNIT GYP GYPSUM PLWD PLYWOOD UL UNDERWRITER'S LABORATORY CO CHANGE ORDER PR PAIR UNFIN UNFINISHED COL COLUMN HCAP HANDICAP(PED) PREFA PREFABRICATED UNO UNLESS NOTED OTHERWISE CONIC CONCRETE HDWR; HARDWARE B UR URINAL CONN CONNECTION HW PRHT PARTIAL HEIGHT CONS CONSTRUCTION HM HOLLOW METAL PROJ PROJECT VB VINYL BASE T HORIZ HORIZONTAL PSF POUNDS PER SQUARE FOOT VCT VINYL COMPOSITION TILE CONT CONTINUOUS HP HIGH POINT PSI POUNDS PER SQUARE INCH VERT VERTICAL CONT CONTRACT(OR) HR HOUR PT PAINT VEST VESTIBULE R HT HEIGHT PTD PAINTED VTR VENT TH RU ROOF CORR CORRIDOR HVAC HEATING, VENTILATION AND AIR PTR PAPER TOWEL RECEPTACLE CPP CARPET PAD CONDITIONING W/ WITH CPT CARPET OF QUARTZ FLOORING W/o WITHOUT CS CONCRETE STAINING IBC INTERNATIONAL BUILDING CODE QS QUARTZ SURFACING WC WATER CLOSET; WALL COVERING CT CERAMIC TILE ID INSIDE DIAMETER QT QUARRYTILE WD WOOD CW CASEWORK IIC IMPACT ISOLATION CLASS CZ QUARTZ WF WIDE FLANGE; WOOD FLOORING CWS CURTAIN WALL SYSTEM INFO INFORMATION WOM WALK OFF MAT INSUL INSULATION or INSULATED R RISER WP WORKING POINT DBL DOUBLE INT INTERIOR RB RESILIENT BASE WS WINDOW SHADES DEPT DEPARTMENT RCP REFLECTED CEILING PLAN WT WALL TILE DF DRINKING FOUNTAIN JAN JANITOR RD ROOF DRAIN WWF WELDED WIRE FABRIC DIA DIAMETER JT JOINT RE REFER TO or REFERENCE GENERAL DEMOLITION NOTES 1. DASHED LINES ON DEMOLITION PLAN INDICATES EXISTING MATERIALS TO BE DEMOLISHED, UNLESS NOTED OTHERWISE. EQUIPMENT TO BE REUSED SHALL BE STORED AND PROTECTED FROM DAMAGE DURING CONSTRUCTION 2. THE FOLLOWING DEFINITIONS APPLY FOR THIS PROJECT: DEMOLISH: TEAR DOWN COMPLETELY, REMOVE FROM SITE REMOVE: DISMANTLE, PROTECTAND STORE FOR COORDINATION WITH PROPERTY MANAGEMENT OR OWNER 3. CONTRACTOR SHALL PROVIDE PROTECTION AS APPROPRIATE TO PREVENT DAMAGE TO EXISTING FINISHES INDICATED TO REMAIN AND AREAS NOT IN THE SCOPE OF WORK. ANY DAMAGE RESULTING FROM CONSTRUCTION WILL BE REPAIRED TO ITS ORIGINAL STATE. 4. DEMOLITION EXPOSING THE INTERIOR OF THE BUILDING TO THE OUTSIDE ELEMENTS OR TO THE PUBLIC SHALL BE PROPERLY SEALED AND PROTECTED TO ELIMINATE DAMAGE FROM VANDALISM OR WEATHER DURING CONSTRUCTION. 5. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND REPORT PROBLEMS OR DISCREPANCIES IN THE PLANS AT ONCE TO THE ARCHITECT. ALL WORK INVOLVED AT SAID QUESTIONED AREA SHALL BE HALTED UNTIL ARCHITECT GIVES NOTICE TO PROCEED. 6. UNLESS DETAILED OR SCHEDULED OTHERWISE, ALL AREAS AFFECTED BY DEMOLITION WORK SHALL BE PATCHED AND/OR REPAIRED TO MATCH EXISTING ADJACENT SURFACES AND FINISHED. REPAIR SHALL MATCH EXISTING ADJACENT SURFACES. 7. GENERAL CONTRACTOR TO PROPERLY DISPOSE OF DEMO ITEMS, UNLESS OTHERWISE NOTED. 8. DEMOLITION SCOPE OF WORK WITHIN THE KITCHEN AND BATHROOMS TO INCLUDE DRYWALL AND SUBFLOOR AS REQUIRED TO REPAIR ANY MOLD AND WATER DAMAGE. REPAIR DAMAGE TO STRUCTURAL ELEMENTS AS REQUIRED. a r r QI I COPYRIGHT KEITH SCHMELZER GENERAL PLAN NOTES 1. THE APPLICABLE CODE IS 2018 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED BYTHE CITY OF WHEAT RIDGE, CO, INCLUDING AMENDMENTS. 1. REFER TO SHEET G0.01 FOR ARCHITECTURAL SYMBOLS 2. INTERIOR DIMENSIONAL REFERENCES REFER TO FINISHED FACE OF PARTITION, UNLESS NOTED OTHERWISE 3. CONTRACTOR TO VERIFY DIMENSIONS IN FIELD WHERE REQUIRED PRIOR TO PROCUREMENT/FABRICATION. 4. UNLESS NOTED OTHERWISE ALL PARTITION TYPES ARE 2x4 NOMINAL WOOD STUD WITH 5/8" GYP BOARD APPLIED TO EACH FACE. 5. PROVIDE MOLD & MOISTURE RESISTANT GYPSUM BOARD IE USG MOLD TOUGH OR ALTERNATE ACCEPTABLE TO ARCHITECTAT BATHROOM LOCATIONS NOT INDICATED TO RECEIVE TILE, KITCHEN BACKSPLASH, AND LAUNDRY ROOM LOCATIONS. 6. PROVIDE CEMENTITIOUS BACKER BOARD IE USG DUROCK OR ALTERNATE ACCEPTABLE TO ARCHITECT AT BATHROOM LOCATIONS INDICATED TO RECEIVE TILE. PROVIDE FLUID APPLIED WATERPROOFING / CRACK ISOLATION MEMBRANE IE LATICRETE HYDROBAN OR ALTERNATE AS ACCEPTABLE TO ARCHITECT. 7. REPAIR OR REPLACE THERMAL INSULATION WHERE EXPOSED AT EXTERIOR WALLS / CEILING. EXTERIOR WALL INSULATION TO BE R-21 KRAFT FACED FIBERGLASS BATT INSULATION, OR R-15 KRAFT -FACE FIBERGLASS BATT INSULATION WHERE EXISTING 2x4 WALLS WOULD PREVENT PROPER INSTALLATION OF R-21 INSULATION. 8. PROVIDE R-49 BLOWN -IN INSULATION AT ATTIC SPACE. MAINTAIN 2" AIR SPACE TO UNDERSIDE OF ROOF SHEATHING TO PRESERVE ATTIC VENTILATION. 9. NEW DOORS TO BE FLUSH PANEL STAINED WOOD TO MATCH EXISTING UNLESS NOTED OTHERWISE. ARCHITECTURAL SYMBOLS GRID LINE AND IDENTIFICATION NORTH DIRECTION MARK PLAN TRUE LE0 ELEVATION MARK 100'-0" SPOT ELEVATION MARK ROOM NAME ROOM NAME TAG 01 EXTERIOR ELEVATION MARK J( SHEET NUMBER 2014A DOOR NUMBER TAG A3.01 XINTERIOR ELEVATION MARK X A6.01 X SH EET NUMBER X 2.01 KEYNOTE TAG OA WIN DOW TAG LU REVISION TAG 10 -0-1 CEILING HEIGHT TAG SECTION MARK SIM[C8_81 CASEWORKTAG X A1.01 SH EET NUMBER WALL -1 EXTERIOR WALL TAG CALLOUT MARK 32-A INTERIOR PARTITION SIM 1;7 TAG 1 A1.01 O LOUVER TAG SHEET NUMBER DRAWING TITLE A View Name IIIIII'r 1/8" = 1'-0" SCALE DRAWING NUMBER HIDDEN LINE (ABOVE, BELOW OR BEYOND) PROPERTY LINE MATCH LINE SCOPE OF WORK LINE MATERIAL LEGEND ALUMINUM STEEL PLASTIC PLYWOOD EARTH ® SOLID SURFACE MATERIAL FINISH -GRADE WOOD GRAVEL GENERAL RCP NOTES CONCRETE GENERAL FINISH NOTES BRICK VICINITY MAP CMU 01.25.2021 STONE GYPSUM BID /PLASTER 1. THE APPLICABLE CODE IS 2017 NATIONAL ELECTRICAL CODE (NFPA 70) AS CEMENTITIOUS FIREPROOFING 1. ALL DRYWALL TO BE LEVEL 4 FINISH TYPICAL. FIRESAFING FFFMRIGID INSULATION RPM SEMI-RIGID INSULATION ALUMINUM STEEL PLASTIC PLYWOOD EARTH ® SOLID SURFACE MATERIAL FINISH -GRADE WOOD GRAVEL GENERAL RCP NOTES GENERAL FINISH NOTES DATE VICINITY MAP 1 01.25.2021 PERMIT SET 1. THE APPLICABLE CODE IS 2017 NATIONAL ELECTRICAL CODE (NFPA 70) AS 1. ALL DRYWALL TO BE LEVEL 4 FINISH TYPICAL. v ADOPTED BYTHE CITYOF WHEAT RIDGE, CO, INCLUDING AMENDMENTS. 2. PAINT ALL WALLS WITH(1)COAT OF PRIMER AND (2)FIN ISH COATS, AS wasm Ave wnem Ave H 1. ALL DIMENSIONS ARE TO CENTER LINE OF FIXTURE UNLESS NOTED REQUIRED, TO ACHIEVE UNIFORM COVERAGE AND FINISH. a - OTHERWISE. 3. PAINT FINISH TO BE SEMIGLOSS FOR BATHROOMS AND TRIM, SATIN FOR ALL 2. REPAIR EXISTING LOW VOLTAGE CONTROLS, TYPICAL. OTHER WALLS, AND FLAT FOR ALL OTHER CEILINGS, TYPICAL. 3. REPAIR EXISTING UNGROUNDED RECEPTACLES, TYPICAL. OUTSIDE OF 4. PROVIDE PAINT DRAW DOWNS FOR ALL PAINT SHOWING COLORS & BATHROOM AND KITCHEN AREA, WALL OPENINGS FOR RECEPTACLES ARE FINISH. - y EXISTING TO REMAIN. 5. PROVIDE GROUT COLOR SAMPLES TO ARCHITECT FOR APPROVAL FOR ALL wenh Ave °""A', 3. EXISTING SQUARE RECESSED DOWNLIGHTS TO BE REPLACED WITH TILE APPLICATIONS. - RETROFIT TYPE FIXTU RE WITHIN EXISTING CEILING OPENING. FIXTU RE TO BEw.am _ o - SURFACE MOUNTED LED OR IC -RATED RECESSED TYPE. 6. BLEND ALL TILE BOXES TO ENSURE UNIFORM COLOR DISTRIBUTION. " n REVIEW TILE LAYOUT WITH ARCHITECT PRIOR TO INSTALLATION. F 4. DEVICES AND WALL PLATES AT KITCHEN BACKSPLASH TO BE BLACK. s w4Hh P1 461,, p, DEVICES AND WALL PLATES ATALL OTHER LOCATIONS TO BE WHITE. 7. PREPARE ALL SURFACES TO RECEIVE TILE TO BE SMOOTH, SQUARE, AND It DATE: 1/25/2021 LEVEL FOR NEW FINISH. DRAWING TITLE: GENERAL NOTES + ABBREVIATIONS °B211fe�r"� •amea,.._h�e 5. RECEPTACLES TO BE MOUNTED 18" A.F.F. UNLESS NOTED OTHERWISE, SEE INTERIOR ELEVATIONS ON A6.01. 8. ALL FLOOR FINISHES SHALL RUN COMPLETELYUNDER ALL MILLWORK, CASEWORK, EQUIPMENT AND APPLIANCES. ve n 9. FLOORING TRANSITIONS NOT TO EXCEED 1/4" MAX VERTICAL STEP, 1/2" - n TOTAL CHANGE IN LEVEL, RAMPED TRANSITION NOT TO EXCEED 1:2 SLOPE " QWhee1 Ridge solar w4.1 Pi W4vh P. I n 9TriChuidgerch 'y Ala M.cemenQ of Wheat RI wmmry w4an vi QHary est chnslien GO IQ Valera Heet Asian M.r. Communityv g rw City of Wheat Ridge Building Division 00 M 0 I -O W00 Wp �U W W Uw N Z C) J W LV w 0 W Q V LV N = co DC STAMP: P ��`\ SChme/z , a , 00406123 I/25/2l �RCHITEG� ISSUE NO. DATE DESCRIPTION 1 01.25.2021 PERMIT SET PROJECT NO. 2020 SCHMELZER RESIDENCE DATE: 1/25/2021 G0.01 DRAWING TITLE: GENERAL NOTES + ABBREVIATIONS COPYRIGHT KEITH SCHMELZER 1 DEMOLITION PLAN 1/4" = 1'-0" SCALE : 1/4" = T-0" 0 - NORTH DEMOLITION PLAN NOTES 1. DASHED LINES ON DEMOLITION PLAN INDICATES EXISTING MATERIALSTO BE DEMOLISHED, UNLESS NOTED OTHERWISE. EQUIPMENTTO BE REUSED SHALL BE STORED AND PROTECTED FROM DAMAGE DURING CONSTRUCTION. 2. THE FOLLOWING DEFINITIONS APPLY FOR THIS PROJECT: DEMOLISH: TEAR DOWN COMPLETELY, REMOVE FROM SITE REMOVE: DISMANTLE, PROTECTAND STORE FOR COORDINATION WITH PROPERTY MANAGEMENT OR OWNER 3. CONTRACTOR SHALL PROVIDE PROTECTION AS APPROPRIATE TO PREVENT DAMAGE TO EXISTING FINISHES INDICATED TO REMAIN AND AREAS NOT IN THE SCOPE OF WORK. ANY DAMAGE RESULTING FROM CONSTRUCTION WILL BE REPAIRED TO ITS ORIGINAL STATE. 4. DEMOLITION EXPOSING THE INTERIOR OF THE BUILDING TO THE OUTSIDE ELEMENTS OR TO THE PUBLIC SHALL BE PROPERLY SEALED AND PROTECTED TO ELIMINATE DAMAGE FROM VANDALISM OR WEATHER DURING CONSTRUCTION. 5. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND REPORT PROBLEMS OR DISCREPANCIES IN THE PLANS AT ONCE TO THE ARCHITECT. ALL WORK INVOLVED AT SAID QUESTIONED AREA SHALL BE HALTED UNTIL ARCHITECT GIVES NOTICE TO PROCEED. 6. UNLESS DETAILED OR SCHEDULED OTHERWISE, ALL AREAS AFFECTED BY DEMOLITION WORK SHALL BE PATCHED AND/OR REPAIRED TO MATCH EXISTING ADJACENT SURFACES AND FINISHED. REPAIR SHALL MATCH EXISTING ADJACENT SURFACES. 7. GENERAL CONTRACTOR TO PROPERLY DISPOSE OF DEMO ITEMS, UNLESS OTHERWISE NOTED. 8. DEMOLITION SCOPE OF WORK WITHIN THE KITCHEN AND BATHROOMS TO INCLUDE DRYWALL AND SUBFLOOR AS REQUIRED TO REPAIR ANY MOLD AND WATER DAMAGE. REPAIR DAMAGE TO STRUCTURAL ELEMENTS AS REQUIRED. PLAN KEYNOTES 02.1 REMOVE DOOR PANEL TO BE REUSED 02.2 REMOVE FIXTURE TO BE REUSED 02.3 SALVAGE APPLIANCE, TO BE RELOCATED TO GARAGE 02.4 REMOVE FIXTURE TO INCLUDE REDUNDANT DRUM TRAP Provide Clean Air Report to Building Inspector at First Inspection to Verify Asbestos Particles are No Longer Present City of Wheat Ridge Building Division M M 0 I—O W00 WO �U W W U) W NZU0 J W LV w 0 W Q VLV N = co DC � STAMP: 00406123 �RCHITEG� ISSUE NO. DATE DESCRIPTION 1 01.25.2021 PERMIT SET PROJECT NO. 2020 SCHMELZER RESIDENCE DATE: 1/25/2021 D1.01 DRAWING TITLE: DEMOLITION PLAN COPYRIGHT KEITH SCHMELZER 1 DEMOLITION REFLECTED CEILING PLAN 1/4" = 1'-0" SCALE : 1/4" = T-0" 0 - NORTH GENERAL RCP NOTES 1. THE APPLICABLE CODE IS 2017 NATIONAL ELECTRICAL CODE (NFPA 70) AS ADOPTED BY THE CITY OF WHEAT RIDGE, CO, INCLUDING AMENDMENTS. 1. ALL DIMENSIONS ARE TO CENTER LINE OF FIXTURE UNLESS NOTED OTHERWISE. 2. REPAIR EXISTING LOW VOLTAGE CONTROLS, TYPICAL. 3. REPAIR EXISTING UNGROUNDED RECEPTACLES, TYPICAL. OUTSIDE OF BATHROOM AND KITCHEN AREA, WALL OPENINGS FOR RECEPTACLES ARE EXISTING TO REMAIN. 3. EXISTING SQUARE RECESSED DOWN LIGHTS TO BE REPLACED WITH RETROFIT TYPE FIXTURE WITHIN EXISTING CEILING OPENING. FIXTURE TO BE SURFACE MOUNTED LED OR IC -RATED RECESSED TYPE. 4. DEVICES AND WALL PLATES AT KITCHEN BACKSPLASH TO BE BLACK. DEVICES AND WALL PLATES AT ALL OTHER LOCATIONS TO BE WHITE. 5. RECEPTACLES TO BE MOUNTED 18" A.F.F. UNLESS NOTED OTHERWISE, SEE INTERIOR ELEVATIONS ON A6.01. 6. PROVIDE POWER CONNECTION FOR UNDERCABINET LIGHTING. RCP LEGEND LIGHT FIXTURES 0 ROUND DOWNLIGHT, WET RATED ❑ SQUARE DOWNLIGHTTO BE INSTALLED IN EXISTING CEILING OPENINGS, IC RATED SURFACE MOUNTED LIGHT FIXTURE OPENDANT LIGHT FIXTURE CEILING FAN AND LIGHT FIXTURE W REMOTE CONTROL BATH EXHAUST FAN LED TAPE INSTALLED WITHIN EXISTING CEILING COVE, PROVIDE CHANNEL AND LENS SacO SD: SMOKE DETECTOR SD/CO: COMBINATION SMOKE/CO DETECTOR MATERIALS EXISTING V x V CEILING TILE TO BE REMOVED EXISTING CEILING TEXTURE TO REMAIN LAPAINTED GYPSUM BOARD CEILING PLAN KEYNOTES City of Wheat Ridge Building Division co M 0 I— O W °O w0 �U W W U) W N Z C) J W LV w W Q VLV N = ���� STAMP: V �o e„'•O 00406123 �RCHITEG� ISSUE NO. DATE DESCRIPTION 1 01.25.2021 PERMIT SET PROJECT NO. 2020 SCHMELZER RESIDENCE DATE: 1/25/2021 D2.01 DRAWING TITLE: DEMOLITION REFLECTED CEILING PLAN Shower head to shower compar directly at the ei prior to steppini COPYRIGHT KEITH SCHMELZER I ,i, 1 FLOOR PLAN 1/4" = 1'-0" A3.10 SCALE : 1/4" = T-0" 0 - NORTH GENERAL PLAN NOTES 1. THE APPLICABLE CODE IS 2018 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED BYTHE CITY OF WHEAT RIDGE, CO, INCLUDING AMENDMENTS. 1. REFER TO SHEET G0.01 FOR ARCHITECTURAL SYMBOLS 2. INTERIOR DIMENSIONAL REFERENCES REFER TO FINISHED FACE OF PARTITION, UNLESS NOTED OTHERWISE 3. CONTRACTOR TO VERIFY DIMENSIONS INFIELD WHERE REQUIRED PRIOR TO PROCUREMENT/ FABRICATION. 4. UNLESS NOTED OTHERWISE ALL PARTITION TYPES ARE 2x4 NOMINAL WOOD STUD WITH 5/8" GYP BOARD APPLIED TO EACH FACE. 5. PROVIDE MOLD & MOISTURE RESISTANT GYPSUM BOARD IE USG MOLD TOUGH OR ALTERNATE ACCEPTABLE TO ARCHITECT AT BATHROOM LOCATIONS NOT INDICATED TO RECEIVE TILE, KITCHEN BACKSPLASH, AND LAUNDRY ROOM LOCATIONS. 6. PROVIDE CEMENTITIOUS BACKER BOARD IE USG DUROCK OR ALTERNATE ACCEPTABLE TO ARCHITECT AT BATHROOM LOCATIONS INDICATED TO RECEIVE TILE. PROVIDE FLUID APPLIED WATERPROOFING / CRACK ISOLATION MEMBRANE IE LATICRETE HYDROBAN OR ALTERNATE AS ACCEPTABLE TO ARCHITECT. 7. REPAIR OR REPLACE THERMAL INSULATION WHERE EXPOSED AT EXTERIOR WALLS /CEILING. EXTERIOR WALL INSULATION TO BE R-21 KRAFT FACED FIBERGLASS BATT INSULATION, OR R-15 KRAFT -FACE FIBERGLASS BATT INSULATION WHERE EXISTING 2x4 WALLS WOULD PREVENT PROPER INSTALLATION OF R-21 INSULATION. 8. PROVIDE R-49 BLOWN -IN INSULATION AT ATTIC SPACE. MAINTAIN 2" AIR SPACE TO UNDERSIDE OF ROOF SHEATHING TO PRESERVE ATTIC VENTILATION. 9. NEW DOORS TO BE FLUSH PANEL STAINED WOOD TO MATCH EXISTING UNLESS NOTED OTHERWISE. 10. REPLACE EXISTING WATER SHUTOFFS WITH BALL VALVES. PROVIDE SHUTOFF AT EACH FIXTURE / APPLIANCE ACCESSIBLE FROM LIVING SPACE. PLAN KEYNOTES 08.1 RE -INSTALL SALVAGED DOOR PANEL 08.2 PROVIDE LOUVERED DOOR AT LAUNDRYCLOSET 08.3 NEWWINDOW, ANDERSEN 100 SERIES OR ALTERNATE ACCEPTABLE TO ARCHITECT, U -VALUE NOT GREATER THAN 0.30, 1'-6"W CASEMENT MULLED TO 3'-0"W PICTURE x 3'-2"H (VIF) 09.1 NEW WOOD FLOOR, LACE INTO EXISTING WOOD FLOOR 11.1 STACKABLE WASHER/DRYER, BY OWNER. PROVIDE WASHER WALL BOX, ELECTRICAL CONNECTION FOR WASHERAND DRYER, AND EXHAUSTTO EXTERIOR SOFFIT. 22.1 RE -INSTALL SALVAGED FIXTURE 22.2 EXISTING WATER HEATER, REPAIR DRAIN TERMINATION, ADD DRIP LEGTO GAS LINE, ADD DRAIN PAN 22.3 REPLACE EXISTING HOSE BIBB WITH FROST FREE TYPE 22.4 INSTALL PRESSURE REDUCING VALVE AT WATER ENTRYTO REDUCE PRESSURE TO 80 PSI 22.5 INSPECT SEWER SERVICE LINE AND REPAIR AS NECESSARY 23.2 SIDE WALL SUPPLYAIR REGISTER City of Wheat Ridge Building Division M M 0 I—O W00 WG �U W W U) W NZUo J W W W� 0 W Q VLV N = co DC � STAMP: P LIC iO m chM_ 00406123 �RCHITEG� ISSUE NO. DATE DESCRIPTION 1 01.25.2021 PERMIT SET PROJECT NO. 2020 SCHMELZER DATE: RESIDENCE 1/25/2021 A1.01 DRAWING TITLE: FLOOR PLAN COPYRIGHT KEITH SCHME=P 1 Smoke alarms shall comply with 2018 IRC section 314 Carbon monoxide alarms shall comply with 2018 IRC section 315 I I I I 26.1 1111 I -------- Ili-------��I I 11 EQ I II I II I II I I II I NOT IN SCOPE II OF WORK I II II II — — — — — — — — — — — — — — — — — — — — — — — — — — — 0 ROUND DOWNLIGHT, WET RATED ❑ SQUARE DOWNLIGHTTO BE INSTALLED IN EXISTING CEILING 01.25.2021 OPENINGS, IC RATED SURFACE MOUNTED LIGHT FIXTURE S20 I I Gs PC so so N � �1 I PC71 ----------------------------- - — I I REFLECTED CEILING PLAN 1/4" = 1'-0" LL----- -- I I 4 2 01 4 8' 0 - SCALE : 1/4" = T-0" NORTH GENERAL RCP NOTES 1. THE APPLICABLE CODE IS 2020 NATIONAL ELECTRICAL CODE (NFPA 70) ASADOPTED BY THE CITY OF WHEAT RIDGE, CO, INCLUDING AMENDMENTS. 1. ALL DIMENSIONS ARE TO CENTER LINE OF FIXTURE UNLESS NOTED OTHERWISE. 2. REPAIR EXISTING LOW VOLTAGE CONTROLS, TYPICAL. 3. REPAIR EXISTING UNGROUNDED RECEPTACLES, TYPICAL. OUTSIDE OF BATHROOM AND KITCHEN AREA, WALL OPENINGS FOR RECEPTACLES ARE EXISTING TO REMAIN. 3. EXISTING SQUARE RECESSED DOWN LIGHTS TO BE REPLACED WITH RETROFIT TYPE FIXTURE WITHIN EXISTING CEILING OPENING. FIXTURE TO BE SURFACE MOUNTED LED OR IC -RATED RECESSED TYPE. 4. DEVICES AND WALL PLATES AT KITCHEN BACKSPLASH TO BE BLACK. DEVICES AND WALL PLATES AT ALL OTHER LOCATIONS TO BE WHITE. 5. RECEPTACLES TO BE MOUNTED 18" A.F.F. UNLESS NOTED OTHERWISE, SEE INTERIOR ELEVATIONS ON A6.01. 6. PROVIDE POWER CONNECTION FOR UNDERCABINET LIGHTING. RCP LEGEND LIGHT FIXTURES 0 ROUND DOWNLIGHT, WET RATED ❑ SQUARE DOWNLIGHTTO BE INSTALLED IN EXISTING CEILING 01.25.2021 OPENINGS, IC RATED SURFACE MOUNTED LIGHT FIXTURE OPENDANT LIGHT FIXTURE CEILING FAN AND LIGHT FIXTURE W REMOTE CONTROL BATH EXHAUST FAN LED TAPE INSTALLED WITHIN EXISTING CEILING COVE, PROVIDE CHANNEL AND LENS sacO SD: SMOKE DETECTOR SD/CO: COMBINATION SMOKE/CO DETECTOR MATERIALS EXISTING V x V CEILING TILE TO BE REMOVED EXISTING CEILING TEXTURE TO REMAIN EdPAINTED GYPSUM BOARD CEILING RCP ABBREVIATIONS CO OAKBON MONOXIUL UL I tG I OK D DEDICATED RECEPTACLE, DRYER DS DOOR SWITCH DW DEDICATED RECEPTACLE BELOW COUNTERTOP, DISH WASHER GD DEDICATED RECEPTACLE BELOW COUNTERTOP, GARBAGE DISPOSAL GFI GROUND FAULT INTERRUPT MW DEDICATED RECEPTACLE, MICROWAVE OVER RANGE PC PULL CHAIN R DEDICATED RECEPTACLE, RANGE REF DEDICATED RECEPTACLE, REFRIGERATOR SD SMOKE DETECTOR W DEDICATED RECEPTACLE, WASHER PLAN KEYNOTES City of Wheat Ridge Building Division M M 0 I—O W00 w0 �U W W U)w N Z C) J W LV w 0 FL W VLU N = ���� STAMP: Schme�z V �o e„'•O 00406123 �RCHITEG� ISSUE NO. DATE DESCRIPTION 1 01.25.2021 PERMIT SET PROJECT NO. 2020 SCHMELZER RESIDENCE DATE: 1/25/2021 A2.01 DRAWING TITLE: REFLECTED CEILING PLAN COPYRIGHT KEITH SCHMELZER FINISH SCHEDULE MASTER BATH BATH NAME/TYPE MFR MODEUSERIES SIZEIFORMAT COLOR/FINISH COMMENTS FLOOR TILE FLOOR TILE TECTURA MICRO 12" SQUARE TZ -13 BASE m BASE FINISHES WALL TILE SPECCERAMICS FINISHES WALL TILE CLE TILE ZELLIGE 4" SQUARE, 1/16" JOINT TEA CEREMONY, GROUT COLOR TBD OUTSIDE CORNERS TO BE MITERED, PROVIDE MAPS ULTRACOLOR PLUS FA GROUT, PROVIDE MIRACLE SEALANTS 511 POROUS PLUS SEALANT SATIN WALL PAINT SHERWIN-WILLIAMS TBD SHERWIN-WILLIAMS SEMIGLOSS FLAT WALL COVERING YORK RMK11436WP LILY PAD AQUA CEILING PAINT SHERWIN-WILLIAMS SW7757 HIGH REFLECTIVE WHITE STAINLESS STEEL SEMIGLOSS RANGE ACCESSORIES WEST ELM 6959391 24" ANTIQUE BRASS SET OF FOUR ACCESSORIES ACCESSORIES WEST ELM 15122187 24" POLISHED NICKEL SET OF FOUR ACCESSORIES IMEDICINE CABINET I WEST ELM 19700673 1 JACORN IRECESSED MOUNTED STAINLESS STEEL SHOWER DOOR I I 148-W x 80"H VANITY CABINET KITCHEN CABINETS IKEA 1BODARP 60"Wx20"Dx36"H CASEWORK IVANITY CABINET IIKEA IGODMORGON / BR VIKEN 32" ISTAINEDASH IWALL MOUNTED KITCHEN COUNTERTOP LINEN CABINET I I BLACK HONED 30"Wx20"Dx80"H WATER CLOSET KOHLER WELLWORTH K-11464-0 PLUMBING WHITE IKEA PLUMBING ISHOWER PAN IKOHLER IRELY li 34"x48" IWHITE REINSTALL EXISTING IBLACK SHOWER SYSTEM JAKDY ISPOO57 165., SPACE GRAY PLUMBING BATH FAUCET DELTA TRINSIC T17T459-CZH2O-B1 OMLOPP CHAMPAGNE BRONZE EXHAUST FAN PANASONIC 1WHISPERWALL FV-08WQ1 15.75"x20.375" WHITE 1WET LOCATION ELECTRICAL ICAN LIGHT DELTA I CHAMPAGNE BRONZE IWET LOCATION, IC RATED HOUSING I HAMPTON BAY VANITY SCONCE IWEST ELM 11683047 1 POLISHED NICKEL IWET LOCATION BATH KITCHEN NAME/TYPE MFR MODEL/SERIES SIZE/FORMAT COLOR/FINISH COMMENTS FLOOR TILE FLOOR TILE DALTILE BRAZIL GREY 12" SQUARE SLATE BASE m BASE FINISHES WALL TILE SPECCERAMICS FINISHES WALL TILE ZIA TILE SUBWAY 2"x8", 1/16" JOINT MIDNIGHT BLUE, GROUT COLOR TBD PROVIDE SCHLUTER JOLLY AT EXPOSED EDGES, PROVIDE MAPEI FLEXCOLOR CG GROUT, PROVIDE MIRACLE SEALANTS 511 POROUS PLUS SEALANT SATIN WALL PAINT SHERWIN-WILLIAMS TBD SHERWIN-WILLIAMS SEMIGLOSS FLAT CEILING PAINT SHERWIN-WILLIAMS SW7757 HIGH REFLECTIVE WHITE SEMIGLOSS REFRIGERATOR SAMSUNG jRS25J500DSR STAINLESS STEEL PROVIDE ICE MAKER WALL BOX RANGE ACCESSORIES WEST ELM 6959391 24" ANTIQUE BRASS SET OF FOUR ACCESSORIES MIRROR STAINLESS STEEL 32" DIAMETER GARBAGE DISPOSAL BY OWNER I SHOWER ROD IKOHLER 1EXPANSE K -9351 -BS DISHWASHER I BRUSHED STAINLESS jSHX3AR75UC STAINLESS STEEL VANITY CABINET KITCHEN CABINETS IKEA 1BODARP 60"Wx20"Dx36"H CASEWORK VANITY COUNTERTOP IMSI ISTILE JiBLACK CALACATTALUCCA KITCHEN COUNTERTOP LINEN CABINET I I BLACK HONED 30"Wx20"Dx80"H SCHMELZER RESIDENCE DATE: 1/25/2021 PLUMBING KITCHEN SINK IKEA HILLESJON 291/2"x18 1/8" WATER CLOSET DOUBLE BOWL, UNDERMOUNT KITCHEN FAUCET DELTA REINSTALL EXISTING IBLACK BATHTUB KOHLER EXPANSE K -1118 -LA -0 60"x30-36" WHITE PLUMBING BATH FAUCET DELTA TRINSIC T17T459-CZH2O-B1 OMLOPP CHAMPAGNE BRONZE VANITY SINK KOHLER CAXTON K-20000-0 15.75"x20.375" WHITE RECTANGULAR UNDERMOUNT PENDANT LIGHT VANITY FAUCET DELTA TRINSIC 3559-CZMPU-DST-B1 CHAMPAGNE BRONZE TRACK LIGHT I HAMPTON BAY 1805029 EXHAUST FAN 1PANASONIC RWALL FV-08WQ1 WHITE WET LOCATION ELECTRICAL CAN LIGHT WET LOCATION, IC RATED HOUSING VANITY PENDANT I IWET LOCATION KITCHEN 42" . 36" 24" 24" 7 KITCHEN WEST IT 3/8" = 1'-0" 111,1711 NAME/TYPE MFR MODEUSERIES SIZEIFORMAT COLORIFINISH COMMENTS DI FLOOR TILE BEDROSIANS WATERMARK 12"x24" \ BASE m FINISHES WALL TILE SPECCERAMICS INAX YUKI BORDER 12"x12" MOSAIC BLACK WALL PAINT SHERWIN-WILLIAMS TBD SATIN CEILING PAINT SHERWIN-WILLIAMS SW7757 HIGH REFLECTIVE WHITE FLAT REFRIGERATOR SAMSUNG jRS25J500DSR STAINLESS STEEL PROVIDE ICE MAKER WALL BOX RANGE SAMSUNG INE58F971OWS STAINLESS STEEL APPLIANCES MICROWAVE LG ILGLMV2031ST STAINLESS STEEL GARBAGE DISPOSAL I STAINLESS STEEL DISHWASHER BOSCH jSHX3AR75UC STAINLESS STEEL KITCHEN CABINETS IKEA 1BODARP CASEWORK ICABINET PULLS IKEA 1HACKAS JiBLACK KITCHEN COUNTERTOP I IGRANITE I BLACK HONED PROJECT NO. 2020 SCHMELZER RESIDENCE DATE: 1/25/2021 PLUMBING KITCHEN SINK IKEA HILLESJON 291/2"x18 1/8" STAINLESS STEEL DOUBLE BOWL, UNDERMOUNT KITCHEN FAUCET DELTA ESSA9113-BL-DST-B1 I IBLACK UNDER CABINET LIGHT IKEA OMLOPP SURFACE MOUNT LIGHT BROMI B4106BBG BLACK AND GOLD ELECTRICAL PENDANT LIGHT IBLOOMINGVILLE IGLASS PENDANT I IGREEN TRACK LIGHT I HAMPTON BAY 1805029 42" . 36" 24" 24" 7 KITCHEN WEST IT 3/8" = 1'-0" 111,1711 15" 30" 15" � 30" 4 BATH SOUTH 3/8" = 1'-0" m ih 2 M BATH EAST 3/8" = 1'-0" . 36" II 24" 30" 50" G SOUTH KITCHEN I THS V 3/8" = 1'-0" GENERAL FINISH NOTES 1. ALL DRYWALL TO BE LEVEL 4 FINISH TYPICAL. 2. PAINT ALL WALLS WITH (1) COAT OF PRIMER AND (2) FINISH COATS, AS REQUIRED, TO ACHIEVE UNIFORM COVERAGE AND FINISH. 3. PAINT FINISH TO BE SEMIGLOSS FOR BATHROOMS AND TRIM, SATIN FOR ALL OTHER WALLS, AND FLAT FOR ALL OTHER CEILINGS, TYPICAL. 4. PROVIDE PAINT DRAW DOWNS FOR ALL PAINT SHOWING COLORS & FINISH. 5. PROVIDE GROUT COLOR SAMPLES TO ARCHITECT FOR APPROVAL FOR ALL TILE APPLICATIONS. 6. BLEND ALL TILE BOXES TO ENSURE UNIFORM COLOR DISTRIBUTION. REVIEW TILE LAYOUT WITH ARCHITECT PRIOR TO INSTALLATION. 7. PREPARE ALL SURFACES TO RECEIVE TILE TO BE SMOOTH, SQUARE, AND LEVEL FOR NEW FINISH. 8. ALL FLOOR FINISHES SHALL RUN COMPLETELY UNDER ALL MILLWORK, CASEWORK, EQUIPMENT AND APPLIANCES. 9. FLOORING TRANSITIONS NOT TO EXCEED 1/4" MAX VERTICAL STEP, 1/2" TOTAL CHANGE IN LEVEL, RAMPED TRANSITION NOT TO EXCEED 1:2 SLOPE i 3 BATH NORTH 3/8" = 11-011 1, - 0„ 1 M BATH NORTH 3/8" = 1'-0" 30" C KITCHEN NORTH V 3/8" = 1'-0" 30" City of Wheat Ridge Building Division M M C) 0 W °O W0 �U W W U) U-1 NZUo J W W w� �Q W VW CN _ co DC � STAMP: �PpO LI�F� o0406 /2S �RCHITEG� ISSUE NO. DATE DESCRIPTION 1 DI > \ / m ro 15" 30" 15" � 30" 4 BATH SOUTH 3/8" = 1'-0" m ih 2 M BATH EAST 3/8" = 1'-0" . 36" II 24" 30" 50" G SOUTH KITCHEN I THS V 3/8" = 1'-0" GENERAL FINISH NOTES 1. ALL DRYWALL TO BE LEVEL 4 FINISH TYPICAL. 2. PAINT ALL WALLS WITH (1) COAT OF PRIMER AND (2) FINISH COATS, AS REQUIRED, TO ACHIEVE UNIFORM COVERAGE AND FINISH. 3. PAINT FINISH TO BE SEMIGLOSS FOR BATHROOMS AND TRIM, SATIN FOR ALL OTHER WALLS, AND FLAT FOR ALL OTHER CEILINGS, TYPICAL. 4. PROVIDE PAINT DRAW DOWNS FOR ALL PAINT SHOWING COLORS & FINISH. 5. PROVIDE GROUT COLOR SAMPLES TO ARCHITECT FOR APPROVAL FOR ALL TILE APPLICATIONS. 6. BLEND ALL TILE BOXES TO ENSURE UNIFORM COLOR DISTRIBUTION. REVIEW TILE LAYOUT WITH ARCHITECT PRIOR TO INSTALLATION. 7. PREPARE ALL SURFACES TO RECEIVE TILE TO BE SMOOTH, SQUARE, AND LEVEL FOR NEW FINISH. 8. ALL FLOOR FINISHES SHALL RUN COMPLETELY UNDER ALL MILLWORK, CASEWORK, EQUIPMENT AND APPLIANCES. 9. FLOORING TRANSITIONS NOT TO EXCEED 1/4" MAX VERTICAL STEP, 1/2" TOTAL CHANGE IN LEVEL, RAMPED TRANSITION NOT TO EXCEED 1:2 SLOPE i 3 BATH NORTH 3/8" = 11-011 1, - 0„ 1 M BATH NORTH 3/8" = 1'-0" 30" C KITCHEN NORTH V 3/8" = 1'-0" 30" City of Wheat Ridge Building Division M M C) 0 W °O W0 �U W W U) U-1 NZUo J W W w� �Q W VW CN _ co DC � STAMP: �PpO LI�F� o0406 /2S �RCHITEG� ISSUE NO. DATE DESCRIPTION 1 01.25.2021 PERMIT SET PROJECT NO. 2020 SCHMELZER RESIDENCE DATE: 1/25/2021 A6.01 DRAWING TITLE: INTERIOR ELEVATIONS Lf&21 INSPECTION RECORD Occupancy/Type INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection k INSPECTION REQUEST LINE: (303) 234-5933 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underground or Below/in-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Comments • 9:;+Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof 16.4 -n -'0 Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued prf)tect This Card From The Weather a City of Wheat Ridge y Residential Roofing PERMIT - 201706889 PERMIT NO: 201706889 ISSUED: 09/03/2017 JOB ADDRESS: 4621 Pierce ST EXPIRES: 09/03/2018 JOB DESCRIPTION: Residential Re -roof to install Malarkey Nista asphalt shingles with decking 28 sq. Pitch = 4/12 *** CONTACTS *** OWNER (303)421-9346 APODACA JAY SUB (720)209-4635 Michael Lindberg 140280 Pioneer Home Solutions *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,383.00 FEES Total Valuation 0.00 Use Tax 197.04 Permit Fee 204.30 ** TOTAL ** 401.34 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior t,; t ::ai approval. Installation of roof sheathing (new or overlay) is required on the entire roc when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. City of Wheat Ridge Residential Roofing PERMIT - 201706889 PERMIT NO: 201706889 ISSUED: 09/03/2017 JOB ADDRESS: 4621 Pierce ST EXPIRES: 09/03/2018 JOB DESCRIPTION: Residential Re -roof to install Malarkey Vista asphalt shingles with decking 28 sq. Pitch = 4/12 *** CONTACTS *** OWNER (303)421-9346 APODACA JAY SUB (720)209-4635 Michael Lindberg 140280 Pioneer Home Solutions *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,383.00 FEES Total Valuation 0.00 Use Tax 197.04 Permit Fee 204.30 ** TOTAL ** 401.34 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. A City of Wheat Ridge Residential Roofing PERMIT - 201706889 PERMIT NO: 201706889 ISSUED: 09/03/2017 JOB ADDRESS: 4621 Pierce ST EXPIRES: 09/03/2018 JOB DESCRIPTION: Residential Re -roof to install Malarkey Vista asphalt shingles with decking 28 sq. Pitch = 4/12 I, by my signature, do hereby attest that the work to be performed shall comply with all accompany ingg approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by, the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. urther attest that I am legally authorized to include all entities named within this document as parties to the work to be performe an ha all rk�s e perform is disclosed in this docume 5d/or itp' accompanying approved plans and specifications. Sign;kure A OWNER ot^NTRACTOR (Circle one) Dhte I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal workw ut written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicabl a or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz Jo (l 0 &(�q � From: no-reply@c i.wheatridge.co.us Vt Tt� Sent: Wednesday, August 30, 2017 4:19 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? W /0, WI How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 4621 Pierce St Property Owner Name Jay Apodaca Property Owner Phone 303-421-9346 Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Field not completed. Address 49 4 Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract Yes Jay Apodaca Contract. PDF.pdf CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) Pioneer Home Solutions 140280 720-209-4635 700 N. colorado Blvd Unit 170 Contractor Email Address mike@phsdenver.com Retype Contractor Email Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work: Project Value (contract value or cost of ALL materials and labor) mike@phsdenver.com 28 Are you re -decking the Yes roof? Does the scope of the No project include a flat roof (less than 2:12 pitch)? 50 Does the scope of the project include a pitched roof (2:12 or greater pitch)? How many squares are part of the pitched roof? Describe the roofing materials for the pitched roof: Type of material for the pitched roof: Yes 28 Malarkey vista asphalt shingle Asphalt Provide any additional Remove and replace shingles on house detail here on the description of work. (Is th' e�-a-hett ' garage? What is the roof iI Z pitch? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have been authorized by the legal owner of the property to submit this application Yes Yes Yes Yes 51 and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Michael Lindberg Email not displaying correctly? View it in your browser. 52 _ 5 D'- - C, 700 N. Colorado Blvd Suite 170 Denver, CO 80206 720 209 4635 phsdenver,com info@phsdenver.com ACCREDITED BUSINESS Customer �b�----I 4 �+�1� - ---Phone-03- t� � � �Y� Email I&A41-E'TqUt \ R "s City State Addres-,., Pioneer Nome Solutions, LLC (hereinafter "PHS") agrees to provide the labor and materials foria� insurance ; Claim r 6L - dI i - with the approximate "commencement" of work the creek of i (per terms). The customer gives PHS permission to speak and negotiate with their insurance 4ompany to establish a total Replacement Cost Value (RCV) for repairs. The customer has the right to rescind this contract v.'ithin 72 hours of entering into it and can notify PHS of rescind via email, mail, or in person. SPECIFICATIONS OF MATERTAI_S AND WOPK PFIRFORNIF0 41koofrng _Tear -off, haul R dispose, of existing roofiac material Install pipe jacks _install roof vents Install f2?C� �s-y'%c-;r:.�Tj�e 1.1 itSn71n Che Color (�vi,�� Install felt paper _Install ice & water shield if required by city code and in accordance with Naim ,XInstall drip edge if required by city code and in accordance with clai_Kbean up properk,Lifetime workmanship warranty _' Customer is responsible for all HOA approvals on materials and colors " Customer is responsible for _oordinating and scheduling any satellite dish remounting, realignment and calibration with their service provider _ Additional Work F. Specifications The total cost will be equal to the full and final Replacement Cost Value (RCV) as determined between the insurance company and PHS. Customer- understands that if s/he has RCV coverage for these repairs, s/he will be out of pocket the deductible amount and if s/he has Actual Cash Value (ACV) coverage, s/he :ill bF out of pocket the difference between the ACV and RCV. Changes (supplements, overhead/profit (O&P;, permits) from the current RCV to the final RCV will be reflected in the insurance company's estimates and loss reports and are considered as updates to this agreement. The customer agrees to pay PHS in whollee for these additions. The current RCV estimate for the specified work and materials for knovm damages is and progress payments will be paid to PHS as received from the insurance company. PHS shall hold in trust any payment from the customer until the delivery of materials at the site or has performed a majority of the roofing work on the property. Make all checks payable to Pioneer Home Solutions Half down of RCV upon DELIVERY of materials - � — r 7`Jr� Date Initials Remainder of ACV payout upon completion S Date Initials Remainder of RCV, O&P, supplcments, permit fees 5 Date Initials FINAL TOTAL/RCV Date Initials Customer and PHS agree to the materials ,,�j(epecificrattions, terms stated herein, on back and suPp!ements to this agreement. Customer I r!' '' �:-f ►l PHS, by `jrepresentative Signature l�� 1 Signature. Date l0 - Date c s Vx A i k CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: f-- WAL- F-Dbr' Job Address: AU2-\ PI r 12Gi= ST Permit Number: 2O1 -10V bbd ❑ No one available for inspection: Time (90M Re -Inspection required: Yes No When corrections have been made, call fo -inspection at 3033-�234-5933 6 ,� Date:10 Inspector: -n- I qn C DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time A PM Re -Inspection required: Yes No When corrections have been made, call for re-ip pection303- 4-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE 301ION S11413AOW3t1ION 00 :aoloadsul 1 L j :a}ea ££69-6£l-£0£ le uoiloadsupai aol /jeo `apew uaaq aney l uoiloaaaoo uayM, awl ON saA :paainbaa uoi}oadsul-aa U sui aol apopi M auo ON M :aagwnN 11uaaad :ssaippd qof :adA1 uoijoadsul 33IION N01103dSNI xeJ 6 68 -LEE (EOE) (EOE) aull uolloodsul ££6S-b£Z (£0£) uolsinia mpedsul 6uiplin8 39a1a 1V3HM 30 A113 i i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTIONNOTICE Inspection Type: / 19 Job Address: N 6 9 I P ) _� f Permit Number: a j 7©6a`7 ❑ No one available for insp on: Time jIj_ AM/PM Re -Inspection required: (yes) No When corrections have been ma e, call for re -inspection at 303-234-5933 Date: -O/ % Inspector: !� DO NOT REMOVE THIS NOTICE l� i - CITY OF WHEAT RIDGE _1�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M 1)) L 14 JE Job Address: Ll 62.1 f i W e S_ Permit Number: SO M 0 6 ❑ No one available for ins on: Time AM/PM Re -Inspection required:es o When corrections have been made, call for re -inspection at 303-234-5933 Date: 17 Inspector: DO NOT REMOVE THIS NOTICE DEPARTMENT OF GOMMUNITY DEVELOPMENT BUILDING INSPECTION DIVISION PERMIT N0. M93#18733 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONI.Y WHEN SIGNED BY THE CHVEF BUILDING INSPELTOR AND RECEIPTED BEIOW. JOB ADDRESS . . 7- CONTRACTOR ADDRESS ~-57G,0 ri 1)er~~ia? CITY Y) i^v<„Lna~ ZIPCODE 2?619 6 3 PHONE qQ7 - 3 4 u;2 LICENSE NO. I & L 2 a 1. TYPE Growd❑ Wall❑ .~nliiz9ni~ OWNER ,J7I77 ADDRESS 412LW/ ~~rRf Sf PHONE 8S7 - OC,,;tq;2;5 ZIP CODE 80603 CONTRACT PRICE $ DATE .3 A ,5 ~ Otner S a D Face 1 2. MATERIAL To1al SQUare FeN $IGN$ 3 ILLUMINATION YssEI NoD Typs Elect. Psnnit No._ 4. SET BdCK FROM PROPERTV LME N_ S_ E_ W Zons_ Approvsd,ZOna Inapoefor (Spetify which is front) ❑ ❑ ❑ ❑ DieopDroved 1. TYPE ~ MATERIAL FENCES (Specify whieh is frOnt) N_ S_ E_ W Zme_ Apprwed,Zone Inspseta ❑ ❑ ❑ ❑ DiaaODrowd I!. ~C~t' nCF~ To.r dCrc~~~6~ OTHER 2 ~'ublr I]u.Se+ 3. .3- 7A b DRAW SKETCH OR SHOW BELOW, THE FENCE,SIGN,OR OTMER STRUCTURE,GIV1hG pISTANCES FROM PROPERTY LINES. (SETBACKS OR PROJECTIONS INCIUDEA) i ~ J Y F C SPECIFV NORTM ~ N STREE7 NAME SHOW DISiANCES FROM THE MAIN BUILDING 76ADJOINING MOUSES, STREETS, AND PRpPERTY LINES;ON IRREGUTAR LATS, SNOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE OISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMiT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY I1PON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 180 DAYS FROM THE DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN THAT TIME. ELECTRICAL PERMIT STATE IICENSE N0. PLUMBING PERMIT STATE UCENSE NO. MECHANICAL PERMIT ALLIMIMUMWIREUNDERSIZE81lLE6AL F1.00R BSM IST 2N0 3RD 4TH N0. FUEL:CirtIeOMGo{qlPropwm EI Sda N0. WATER CLASET FORCED AIR - BTU TEMPORARY METER WASH BOWL NOT WATER - BTU NEW SERVICE - AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTING SINN OTHER MEATING GARBAGE DISP REFRIGERATION SYSTEM POWER SUB-GFCUITS WATER HEATER Refri aranf Group UTILITY(RANGE,OISPOSER,ETC) AUTO. WASHER pourMs Chor a FIXTURES DISH WASHER AUTOMATIC SPRINKLER $YSTEM WIRIN6 MOTOf75 9 CONTROLS FII1((K2 DRAIN ELEVATOR 51GNS URINAL TRANSFORMERS 9 RECTFIERS SEWERS ADDITION TO OI.D WORK OTHER MOTORS OVER I HP TOTAL FI%TURES 1 nareby acNnowledqe thot this appiica- PERMIT FEE _ 3_ CI-0 fion is correct and understand tnot I rojbct until this oppli- not sfart thie USE TAX 6 p eon wtion is approvee. i snan compiy wirn TOTAL FEE ._'2 61 d and to St t f C l i th ora a e o o o e fhe lawa o ths Zoninp Repulationa and Bwldinp Any ot Wheoi Ridpe of1Ae Gt d C APpROVED DeAeeftyEa J . y o e violotlon of the above terme will couse CHIEF 8 S1 I WSPECTOR ityof )ot idqe immediata revocahon of fnis Oermir 2 / - " Date Issued ' " ~oo~icuoU 9ia~a~~~• Mors Thcn 80% Opan❑ Lsss TAOn 80% OpM 3. SET BACN FROM PROPERTY LINE NOT VALID UNLESS CE