Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2970 Upham Street
i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: 7 0 Permit Number: ❑ No one available for inspection„ Time M Re -Inspection required: Ye No When corrections have been made, c edule for re -inspection online at: http✓/www. ci. wheatridge.co. uslinspection Date: la-11417,OW Inspector: DO NOT REMOVE THIS NOTICE 20/ , ca?- �6� October 7, 2020 WALTER KESKE CONSULTING INC. Structural Engineer 8550 W. 64th PLACE • ARVADA, CO 80004 PHONE 303.422-1051 • wgk@wkeskeconsulting.com Colorado Sunroom and Window 641 South Jason Street Denver, CO 80223 RE: Compliance Letter Grantham Residence Sunroom Addition 2970 Upham Street Wheat Ridge, CO 80033 To Whom It May Concern: This letter is to certify that Walter G. Keske observed and reviewed with CSW construction of the sunroom addition at the residence referenced above. Roof framing and ridge to header connection appear to be in accord with engineering plans and specifications. Floor and wall connections appear to be in accord with engineering and satisfactory. All metal to metal connections of the sunroom construction appear to be adequate and in accord with engineering and manufacturer's specifications for support of maximum specified wind and live and dead loads, and are in accord with 20121RC. Please call if there are questions concerning this letter or if I may be of further service Sincerely, KC&C '� 1-"; — Walter G. Keske, P. E. i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: "0 U i -Vo , Permit Number: 2 -) `� 0, ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes 3 No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. usrinspection Date: 1!1-(f .- --r%;') Inspector: / DO NOT REMOVE THIS NOTICE 41 CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re -inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http://Www.ci.wheatridge.co.usfinspection Date: /0 ?Olnspector: DO NOT REMOVE THIS NOTICE dl�ll o wb tq r-�-N WALTER KESKE CONSULTING INC. Structural Ena neer 8550 W. 64th PLACE ° ARVADA, CO 80004 PHONE 303-422-1051 ° wgk@wkeskeconsulting.com March 9, 2020 Colorado Sunroom and Window 641 South Jason Street Denver, CO 80223 RE: Compliance Letter Granthman Residence Sunroom Addition Grade Beams 2970 Upham Street Wheat Ridge, CO 80033 To Whom It May Concern: This letter is to certify that Walter G. Keske reviewed with CSW foundation construction of the sunroom addition at the residence referenced above. The new grade beams and footing appear to be in accord with engineering plans and specifications. All construction appears to be in accord with requirements of 2012 IRC_ Please call if there are questions concerning this letter or if I may be of further service. Sincerely, /A"" '- 10A- Walter G. Keske, P. E. x,��` ®`°b t -15814 9� 31Q46)zo�` ' ® NQ' �. u�trutttttttnt�"' 3011ON SIH13AOM13hf ION 00 :aoloadsul 0 t nom. .() I :a}ea uo►;oedsu!lsn-oo-a8piajeagm •lo mmmll.d;;q je auiluo uoi;oadsui-aa ao{ alnpagos `spew uaaq aneq suoi;oajaoo uayM, oNA :paainbaa uoi}oadsul-aa Nd/NVF, , ,9Wl-L :uoi}oadsui aol apepAe auo ON n of o Ij 1 n :aagwnN Puaaad S U /) LlJ :ssaappd qop :adAl uol}3adsul 30110N N01103dSNl 03140 ss8Z-s£Z (EOE) uolsin,a uoil3odsul 6uiplin8 , 3Jam lV3HM 30 A113 A Al 41 CITY OF WHEAT RIDGE -.A% Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re -inspection required- Yes No I/ When corrections have been made, schedule for re -inspection online at: http.lAvww.ci.wheatridge.co.usllnspection Date:- inspector: DO NOT REMOVE THIS NOTICE 30I10N SIH13/IOW36f ION 00 :ao}oadsul ,�% & (F.—S c : 91ea uoi;oadsuysn-oo-a6piajeagm-lo mmmll.djjy :;e auiluo uoi;oadsui-aa ao{ a/npagos `spew uoaq aneq suoi;oaaaoo uagM. ON ;sPA :paainbaa uoiloadsul-aa Wd/wy quail :uoij3adsui aol apupinle quo ON r i C , c :aagwnN }iwaad 5 uta ('1 Cl L zj :ssaappV qof :adA.L uoilaadsul 331ION N01133dSNI 031HO 958Z-5EZ (EOE) uolslnla uoilaadsul 6uiplln8 3Jala 1V3HM =10 A113 � y I Al i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: '4a) -Z) J544F�_T_ Job Address: f4 Permit Number: ❑ No one available for inspection: Time [Z4fV AM/PM Re -Inspection required: Yes �NoD When corrections have been made, schedule for re -inspection online at: httpJ/www.ci.wheatridge.co.0 nsp ►on I i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: ------c.", r . Job Address: 02-_,t C� Permit Number: 2Q BO �No one available for inspection: Time(Z/PM Re -Inspection required' No When corrections have been made 7lsched,re-inspection online at: httpYA,vww.ci.wheatridge.co.uslins ectign DIns ect ' e:', i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type:" Job Address: Permit Number: No one available for inspection: Time-'AM/PM Re -Inspection requiredYes -;No When corrections have been made, schedule for re -inspection online at: httpY,, Date F No one available for inspection: Time-'AM/PM Re -Inspection requiredYes -;No When corrections have been made, schedule for re -inspection online at: httpY,, Date � ► � i City of Wheat Ridge Residential Sunroom PERMIT - 201902668 PERMIT NO: 201902668 ISSUED: 01/06/2019 JOB ADDRESS: 2970 Upham St EXPIRES: 01/06/2021 JOB DESCRIPTION: New unconditioned sun room - 400 sq ft total **REVISION: Adding a swim spa in sun room, 7  9 ; xl4  9 ; 50 amp 220 vol t Added valuation: $500 **REVISION 2: Add 90 amp subpanel; Added valuation: $550.00 *** CONTACTS *** OWNER ( 7 2 0) 291-3753 GRANTHAM DANIEL T GC (303)801-7511 THOMAS THOMPSON 020342 COLORADO SUNROOM & WINDOWS SUB (303)817-2845 CARL STEPHAN 120180 COLORADO ELECTRICAL CONTRACTOR *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 56,886.00 FEES Total Valuation 0.00 Plan Review Fee 510.84 Use Tax 11194.61 Permit Fee 785.90 ** TOTAL ** 21491.35 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. Landscaping removed or damaged during construction must be replaced prior to final inspection. 1* � � i City of Wheat Ridge �� Residential Sunroom PERMIT - 201902668 PERMIT NO: 201902668 ISSUED: 01/06/2019 JOB ADDRESS: 2970 Upham St EXPIRES: 01/06/2021 JOB DESCRIPTION: New unconditioned sun room - 400 sq ft total **REVISION: Adding a swim spa in sun room, 7  9 ; xl4  9 ; 50 amp 220 vol t Added valuation: $500 **REVISION 2: Add 90 amp subpanel; Added valuation: $550.00 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Revision to Permit Application Date: Thursday, August 27, 2020 3:15:42 PM Revision to Permit Application Permit Number 201902668 assigned to project PROPERTY INFORMATION Permit Number 201902668 Property Address 2970 Upham St Property Owner Name Daniel Grantham Property Owner Phone 720-291-3858 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email dtig55@gmail.com Address CONTRACTOR INFORMATION Contact Name Joe Martinez / Colorado Sunroom & Window Contact Phone Number (enter WITH dashes, eg 303-123-4567) Com@ a FRI91inw-ArGRm 303-715-0777 joem@coloradosunroom.com Retype Contact Email joem@coloradosunroom.com Address DESCRIPTION OF WORK Detailed Revised Scope of Work - Provide a detailed description of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc add sub panel to permit per inspector Engineer Letter (if Field not completed. applicable) Additional Documents on Letter Size Are plans or documents locked for editing? Construction Plans scanned on 11'x17" or larger Additional Project Value Only add what the revised scope of work is valued at. Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Field not completed. No plans needed Field not completed. 300.00 Wheat Ridae electronic oavment form.odf SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have been authorized by the legal owner of the property to submit this Yes Yes Yes application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Submitting Joe Martinez Revision Email not displaying correctly? View it in your browser. From: ioemlcbcoloradosunroom.com To: Kimberly Cook Subject: RE: Online Form Submittal: Revision to Permit Application Date: Tuesday, September 1, 2020 3:20:20 PM Attachments: imaae003 ona untitled Hello, No that was labor only. Material would be additional $250 Thank you, Joe Martinez Project Manager Colorado Sunroom and Window 641 S. Jason St. Denver, CO. 80223 303-715-0777 JOem(cDCOloradosunroom.COm --------- Original Message --------- Subject: RE: Online Form Submittal: Revision to Permit Application From: "Kimberly Cook" <kcook@ci.wheatridge.co.us> Date: 9/1/20 8:56 am To: "joem@coloradosunroom.com" <joem@coloradosunroom.com> Hello, $300 seems low — does this include labor and materials? Thanks, Kim Cook Permit Technician Office Phone: 303-235-2876 of W hteaetige Only farina use oi N, above If You am nor my manded reopent YOU are naked UIL any manager coal age or use Of as ommunalken a prommund If You remove his rommuna Lion in sort sees. mull analogy Lhe original message, and Load by Original message from your lampander and any Laurelled Thank you an joem@mloadosunmom. mm <joem@mloadosunmom. mm> f Tuesday, Septemberl, 2020 853AM Klmbedy Cook <kcook@clwbeatddge mus, jec: REOnline Forth Submittal Isci slon to Permit Application Mrs Cook, 90 amp sub panel. I apologize for the delayed reply. I was out of the office fora days ject Manager iatlo Anniston and asIndow 8. Jason St. ver CO. 88223 Onginal Message Subject R& Online Form Submittal. Revision to Permit Application "Pumberly CookC¢mk4i m6rrtddge iy 8/28/20 8.23 am " CommDev Peemits' Ner tr AcCoaddge Marg ondos di eom mem ondos nmom mm respond to the co l on below by noon or you will need to reapply. Cook rlt Technician e Phone: 303235-2876 VY1!_MtRie ITY NOTICE The .-of came mageop,mmidennal informuen I ImLanded only farina use of or county named some If you are mL Lhe induced moment YOU are nalhad her any backbone, Congo, EIOILUU: pieces or use Of his communduen is precision If you r.: and d I his n in dust please ninify us Immi by I IF energy Lhe original message and delaid Lhe Ed inch your COMPULEN and ads nELwork LO which your Immmer is condoned Thankyou an Commoev Permits t Thursday, August27 2020 3 51 Pon upoppOsdianadia5undynam mm just: Fear Online Forth Submittals Revision to Permit Application any amps is the subpanelP Kim Cook Permit Technician Office Phone: 303235-2876 To W MM �//WINI CONFIDENTIALITY NOTICE Thu. ned.nIcupboneopponflannal inforrannon If OmLicanded only farina I he I no in d Us I ore n I is Us U E d E b va If you are nOL Lhe induced pending, YOU are Lannon her any backbone, a Lend d I on I ion, 2121 Le n a a Lo rage or USE Of I h da am in on 112 1 ion is pro h a IL Ed If you red end d I his communin Lion in arrat gained nanny us unrinedinegy by I IF Building Lhe original message, and delaid Lhe drops I Topped form Your Inarnaudep E no a W nELwork W which your I OMPULer is connection Thank you From: noieolyeta wheatrdee cous mo rsddler wheatrdee m us Sent 1M Thursday, August 202036 P To: Comm oev Permits 6emjit507 Wheat add as 1 J5 Subject: Online Forth Submittal Revision to Permit Application Revision to Permit Application Permit Number 201902660 assigned to project PROPERTY INFORMATION Permit Number 201902668 Property Address 2970 Upham St Property Owner Name Daniel Grantham Property Owner 7262913850 Phone Number (enter 4PPPH dashes, eg 303- 123456]) Property Owner Email tl�sedim Laore Address CONTRACTOR INFORMATION Contact Name Joe Martinez / Colorado Sunroom & Window Contact Phone 303-715-0777 Number (enter WITH dashes, eg 303-123- 4567) Contact Email oem5coloradosunroom. com Address Retype Contact Email oe mQ coloradosunroom _com Address DESCRIPTION OF WORK Detailed Revised Scope of Work - Provide a detailed description of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc add sub panel to permit per inspector Engineer Letter (if Field not completed. applicable) Additional Documents Field not completed. on Letter Size Are plans or No plans needed documents locked for editing? Construction Plans Field not completed. scanned on 11"x17" or larger Additional Project 300.00 Value Only add what the revised scope of work is valued at. Attach City of Wheat Wheat Ridge electronic payment form_ndf Ridge Electronic Payment Form - **DO NOT ATTACH A PICTURE OF A CREDIT CARD** SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Submitting Joe Martinez Revision Email not displaying correctly? View it in your browser. � ► � i City of Wheat Ridge Residential Sunroom PERMIT - 201902668 PERMIT NO: 201902668 ISSUED: 01/06/2019 JOB ADDRESS: 2970 Upham St EXPIRES: 01/06/2021 JOB DESCRIPTION: New unconditioned sun room - 400 sq ft total **REVISION: Adding a swim spa in sun room, 7  9 ; xl4  9 ; 50 amp 220 vol t Added valuation: $500 *** CONTACTS *** OWNER ( 7 2 0) 291-3753 GRANTHAM DANIEL T GC (303)801-7511 THOMAS THOMPSON 020342 COLORADO SUNROOM & WINDOWS SUB (303)817-2845 CARL STEPHAN 120180 COLORADO ELECTRICAL CONTRACTOR *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 56,336.00 FEES Total Valuation 0.00 Plan Review Fee 510.84 Use Tax 11183.06 Permit Fee 785.90 ** TOTAL ** 21479.80 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. Landscaping removed or damaged during construction must be replaced prior to final inspection. 1* � � i City of Wheat Ridge �� Residential Sunroom PERMIT - 201902668 PERMIT NO: 201902668 ISSUED: 01/06/2019 JOB ADDRESS: 2970 Upham St EXPIRES: 01/06/2021 JOB DESCRIPTION: New unconditioned sun room - 400 sq ft total **REVISION: Adding a swim spa in sun room, 7  9 ; xl4  9 ; 50 amp 220 vol t Added valuation: $500 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain thispermit and perform the work described and approved in conjunction with this,permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Revision to Permit Application Date: Friday, May 22, 2020 9:13:13 AM Revision to Permit Application Permit Number 201902668 assigned to project PROPERTY INFORMATION Permit Number 201902668 Property Address 2970 Upham Street Wheatridge Property Owner Name Daniel Grantham Property Owner Phone 720-291-3753 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email drjg55@gmail.com Address CONTRACTOR INFORMATION Contact Name Joe Martinez Contact Phone Number 303-715-0777 (enter WITH dashes, eg 303-123-4567) Contact Email Address joem@coloradosunroom.com Retype Contact Email joem@coloradosunroom.com Address DESCRIPTION OF WORK Detailed Revised Homeowner is putting a Swim Spa in Sunroom 7'x14' 50 amp Scope of Work - 220 volt Provide a detailed description of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc Engineer Letter (if Field not completed. applicable) Additional Documents on Letter Size Are plans or documents locked for editing? Construction Plans scanned on 11'x17" or larger No Additional Project 500 $32.00 x 98sf = $3,136 Value Only add what the revised scope of work is valued at. SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Submitting Joe Martinez Revision Email not displaying correctly? View it in your browser. !0I IN A P 1=VICT1K1(; I IVlnlr, 3-'\ floor plan - exist A2 / scale /4" = 1' - 0" is �2 elevation - existln ) ? 42 scale 1/4" _ " - 0 , ii 0 NOTES: 1. FOUR SEASONS BRAND CATHEDRAL SUNROOM 2. MATERIALS AND DETAILS PER FOUR SEASONS SYSTEM 3. ALL GLASS TO BE TEMPERED 4. GLASS U-VALUE.25 5. SUNROOM IS THERMALLY ISOLATED FROM EXISTING RESIDENCE GENERAL NOTES: CVICTII\Ir'_' I I\11KIr, 4'-4 3/8” 5-3 1/2" 5'-3 1/2" 4'-0 3/8" 19'-3 3/4" floor plan - proposed A2 / scale 14u = ii - O il ON SITE PLANS MUST BE ON SITE FOR INSPECTION ALL Protects are Subject to Field Inspections Approved with redlined notes City of ,MW heatENI W911a APPROVED Review@d for Code Compliance Randy Slusser 5/29/2020 Plans Examiner Date vefidLLr of oermn: fit IswaaeB of o penult or app vvW of poem sp*cgkottoro and owmpufatwm shag not be a pfflwf(o, wan opprorof of, ony nofotim m any of me prow'swns of the bahling rode or of o(y City ardlnonoer. Prange mrw ng to give outhantp to Wloer a mncet the NwAl is of the fwav coda svother ordfnanmofthe Olyehag wt he wg6 REVISION 1. 2015 AND 2018 IRC BUILDING CODES MET (ZC(Z) 2. SNOW LOAD 3,�)LBS. PER SQ. FT. 3. ELECTRICAL 130 VOLT 4. CLIMATE EXPOSURE C Ip<;.y i,egf, C iasd)-),135.mrlC i L (uI>.) ADDITION AREA .............401 SQ. FT. front elevation - A2 scale 1/4" = I' - 0" roposed 12"X36" CONTINUOUS FOOTING I (2) #4 BARS T&B CCsi�[Y1Uai'y V001 t tou eO dotoc(f �0 c<if{<'�y fc,061hilon., Z- 4c(TCb, cfoRyif((ace ro;eJ 2`Bf t,q Ved(*ta(s a( 2W,0,(, D F'Ne lLl O~0 wJ 00 o iy LLJ CO n �0 w O l� <Do p3s0n O O O`') L� O -)a 3t-, = 0 0 Ln f] ��C<�,� � w V v� N z LLJo Jr� J 00 O V c lyO O " 4r D LLJ Rq O~0 wJ 00 o iy Lu �0 w O l� <Do p3s0n O O O`') L� O -)a J = LLJ �> 0 3 f] V � w V N z LLJ z o Lu co w O LIJLLJ O C = Q � w V N z V DATE 11.04.113 DRAUN By RCW CHECKED BY JOB NO. REv151ON5 A2 REVISIO L„City of Wheat Ridge Building Division 11 • Fu • TPv UR SEASONS DETAILS 3\ roof olan ,43j sca'.e 14" = 1' - O" 2\ right side elevation ,43,/ sca le 1/4" = 1' - 0" LIC-;HTING / ELECTRIC,4L LEGEND 0 duplex outlet zm 220V outlet 4,�' recessed downl!ght { U recessed wallwasher - 5tyle per owner �1 0 fixture selection by owner ® recessed downlight - shower suitable Qbath vanity wall light v1F decorative wall light - Interior or exterior EF exhaust fan ceiling Fan switch - one location switch - multiple locations V telephone outlet - GLASS PANEL four (4) pair cats tele./data cable minimum, r - homerun each location 191 televl5 on pre -wire - �1 0 homerun each location ® combo smoke S CO detector ® smoke detector v1F verify location in field with owner S�(w, SPA - is -0 P^P zZc.) V, 4\ electrical plan ,43 j sca le '141' = I' - 0" Where a wall of a dwelling serves as part of the barrier, one of the following conditions shall be met: 9.1. The pool shall be equipped with a powered safety cover in compliance with ASTM F 1346 9.2. Doors with direct access to the pool through that wall shall be equipped with an alarm which produces an audible warning when the door and/or its screen, if present, are opened. The alarm shall be listed and labeled in accordance with UL 2017. The deactivation switch(es) shall be located at least 54 inches 1372 mm above the threshold of the door; or v1F 9.3 Other means of protection, such as self- closing doors with self -latching devices, which shall be approved by the governing body, shall be degree of protection an the protection afforded by Item 9.1 or 9.2. �PTAC L'NIT All glazing in walls shall comply with 2012 IRC R308.4.5 GLASS PANEL GLASS PANEL CLASS PANEL r - GLASS PANEL 5'0X5'0 �1 0 5'0X5'0 O LLJ 5'0X5'0 GO x 50X5'0 i 1 r I I I I 1 I I I left side elevation A3 scale 1/4" = 1' - 01' I_' Iuipment. Where a permanently one 125 -volt, 15- or 20 - branch circuit shall be and not more than 6.0 m (20 ft) from, the inside wall of the pool. This receptacle shall be located not more than 2.0 m (6 ft 6 in.) above the floor, platform, or grade level serving the pool. (2) Circulation and Sanitation System, Location. Receptacles that provide power for water -pump motors or for other loads directly related to the circulation and sanitation system shall be located at least 1.83 m (6 ft) from the inside walls of the pool. These receptacles shall have GFCI protection and be of the grounding type. (3) Other Receptacles, Location. Other receptacles shall be not less than 1.83 m (6 ft) from the inside walls of a pool. (4) GFCI Protection. All 15- and 20 -ampere, single-phase, 125 -volt receptacles located within 6.0 m (20 ft) of the inside walls of a pool shall be protected by a ground -fault circuit interrupter. (5) Measurements. In determining the dimensions in this section addressing receptacle spacings, the distance to be measured shall be the shortest path the supply cord of an appliance connected to the receptacle would follow without piercing a floor, wall, ceiling, doorway with hinged or sliding door, window opening, or other effective permanent barrier D 0LLJ r - N 0= �1 0 O LLJ LLQ GO x J 0 Opo O L CC) 03°o F 1 o QO �0 0 °vn rx, Q I.J 3=O�0 03 O w G v� 0 z �- Q LLJ LJ0 - J CQ J 0 00 LL J Lu d' LLJ f\ / 4 O 1110 N ,ur L\. D W 0LLJ r - N 0= �1 0 O LLJ LLQ x w G Opo 0 L 0 03°o F 1 C QO �0 0 °vn rx, J I.J �o 03 O w G v� 0 z �- W z O LLQ x w G C/l Ltd w G Q � F 1 C QO y n I.J O w G NLi z �- Q LLJ V DATE 11.04.18 DRAIN BY RGIU CHECKED 5Y JOB NO. I REVISIONS I L� REVISI • i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: �...' Job Address: S.1'— Permit Number: ._ _ - r.r. fMad ❑ No one available for inspection: Ti AM/PM Re -Inspection required: Yes (M When corrections have been made, schedule for re -inspection online at: http//www.ci.wheatridge.co.unspqdo C City of Wheat Ridge Q E-Res. Water Heater Replcmnt PERMIT - 202000336 PERMIT NO: 202000336 ISSUED: 02/18/2020 JOB ADDRESS: 2970 Upham St EXPIRES: 02/17/2021 JOB DESCRIPTION: Replacing 50 gallon, 40k BTU gas water heater in basement. Replace furnace with 96% efficient 70000 BTU furnace; Replace AC with 2 ton 16 SEER AC *** CONTACTS *** OWNER (720)291-3858 GRANTHAM DANIEL T SUB (303)757-5661 LARRY D. BELL 017174 BELL PLUMBING & HEATING *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 15,590.00 FEES A/C Replacement 60.00 Furnace Replacement 40.00 Hot Water Heater 40.00 Total Valuation 0.00 Use Tax 327.39 ** TOTAL ** 467.39 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Smoke alarms shall comply with 2012 IRC Section 134. INTERIOR ALTERATIONS, REPAIRS, FUEL -FIRED APPLIANCE REPLACEMENTS, OR ADDITIONS, ANY OF WHICH REQUIRE A BUILDING PERMIT, OCCURS OR WHERE ONE OR MORE ROOMS LAWFULLY USED FOR SLEEPING PURPOSES ARE ADDED SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN FIFTEEN FEET OF THE ENTRANCE TO EACH ROOM LAWFULLY USED FOR SLEEPING PURPOSES City of Wheat Ridge E -Res. Water Heater Replcmnt PERMIT - 202000336 PERMIT NO: 202000336 ISSUED: 02/18/2020 JOB ADDRESS: 2970 Upham St EXPIRES: 02/17/2021 JOB DESCRIPTION: Replacing SO gallon, 40k BTU gas water heater in basement. Replace furnace with 96% efficient 70000 BTU furnace; Replace AC with 2 ton 16 SEER AC I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2. This_permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applic_le code or anA4rdmance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. i CITY OF WHEAT RIDGE J Building Inspection Division r (303) 235-2855 Office INSPECTION NOTICE Inspection Type: �,�00 1'^ b e� Job Address: 2Ct-7� SL Permit Number:() 1 `L� ❑ No one available for inspection: TimetY 0 AM/PM Re -Inspection required: Yes When corrections have been made, schedule for re -inspection online at: http.,Ilwww.ci.wheatridge.co.usvinspection Dater dlG Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: _ c���_2,� ,��rc,°?,:,t �� : ,��V, Job Address: Permit Number: Ck rL .l i ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http.lAvww.cLwheatridge.co.uslinspection Dater' \U ) (, ' Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: 11�6 Ac6247t44 107 S/,,4,3 Job Address: 21.70 V11'31'VAln 3T, Permit Number: ?0, � ef 44.'?i_1.' IJ No one available for inspection: Time(A M„/PM Re -Inspection required: (Y67s No When corrections have been made, schedule for re -inspection online at: http.lAvww.ci.wheatridge.co.uslinspection Date:— -3-in-00 Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge E -Res. Water Heater Replcmnt PERMIT - 202000336 PERMIT NO: 202000336 ISSUED: 02/18/2020 JOB ADDRESS: 2970 Upham St EXPIRES: 02/17/2021 JOB DESCRIPTION: Replacing 50 gallon, 40k BTU gas water heater in basement. *** CONTACTS *** OWNER (720)291-3858 GRANTHAM DANIEL T SUB (303)757-5661 LARRY D. BELL 017174 BELL PLUMBING & HEATING *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,700.00 FEES Hot Water Heater 40.00 Total Valuation 0.00 Use Tax 56.70 ** TOTAL ** 96.70 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Smoke alarms shall comply with 2012 IRC Section 134. INTERIOR ALTERATIONS, REPAIRS, FUEL -FIRED APPLIANCE REPLACEMENTS, OR ADDITIONS, ANY OF WHICH REQUIRE A BUILDING PERMIT, OCCURS OR WHERE ONE OR MORE ROOMS LAWFULLY USED FOR SLEEPING PURPOSES ARE ADDED SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN FIFTEEN FEET OF THE ENTRANCE TO EACH ROOM LAWFULLY USED FOR SLEEPING PURPOSES City of Wheat Ridge E -Res. Water Heater Replcmnt PERMIT - 202000336 PERMIT NO: 202000336 ISSUED: 02/18/2020 JOB ADDRESS: 2970 Upham St EXPIRES: 02/17/2021 JOB DESCRIPTION: Replacing SO gallon, 40k BTU gas water heater in basement. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and its` accompanying approved plans anspecifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any apg c le code or aripfirdinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge 02/18/2020 10t14 CU8A Replacing 50 gallonj CDA022338 AMOUNT RPSP 2970 Upham St 96.70 APPL/P[RMIT NO, 202000336 PAYMENT RECEIVED AMOUNT PP / 6648 96.70 AUTH C0D[� 71368925 TOTAL 96.70 Dina Kemp �1 r%a a6j 3 From: no-reply@ci.wheatri dge.co.us Sent: Monday, February 17, 2020 9:44 AM To: CommDev Permits Subject: Online Form Submittal: Residential Water Heater Replacement Permit Application Residential Water Heater Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WATER HEATERS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes replacement water heater like for like? PROPERTY INFORMATION Property Address 2970 UPHAM ST Property Owner Name DAN GRANTHAM Property Owner Phone 720-291-3858 Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Field not completed. Address (Leave blank if not known) Attach Credit Card CC.pdf Authorization Form - * *DO NOT ATTACH RANDOM DOCUMENTS" CONTRACTOR INFORMATION Contractor Business BELL PLUMBING AND HEATING Name I Contractor's License 17174 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-757-5661 Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address PERMITS@BELLPLUMBING.COM Retype Contractor Email Address DESCRIPTION OF WORK Number of gallons Is the water heater GAS or ELECTRIC? If GAS, enter # of BTUs. If electric, enter n/a Where is the water heater located (for example, basement, crawlspace, etc)? PERMITS@BELLPLUMBING.COM 50 GAS 40000 BASEMENT Project Value (contract 2700.00 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work may not begin on this property until a permit has been issued and posted on the property. Yes Yes 2 I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for NIK LONGHORN Permit Email not displaying correctly? View it in your browser. City of Wheat Ridge Residential Sunroom PERMIT - 201902668 PERMIT NO: 201902668 ISSUED: 01/06/2019 JOB ADDRESS: 2970 Upham St EXPIRES: 01/06/2020 JOB DESCRIPTION: New unconditioned sunroom - 400 sq ft total *** CONTACTS *** OWNER (720)291-3753 GRANTHAM DANIEL T GC (303)801-7511 THOMAS THOMPSON 020342 COLORADO SUNROOM & WINDOWS SUB (303)817-2845 CARL STEPHAN 120180 COLORADO ELECTRICAL CONTRACTOR *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 53,200.00 FEES Total Valuation 0.00 Plan Review Fee 495.14 Use Tax 1,117.20 Permit Fee 761.75 ** TOTAL ** 2,374.09 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. Landscaping removed or damaged during construction must be replaced prior to final inspection. City of Wheat Ridge Residential Sunroom PERMIT - 201902668 PERMIT NO: 201902668 ISSUED: JOB ADDRESS: 2970 Upham St EXPIRES JOB DESCRIPTION: New unconditioned sunroom - 400 sq ft total 01/06/2019 01/06/2020 I, by my signature, do hereby attest that the work to be per shall comply witha ll accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this erm t I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This, permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Divas 6. The ss `nce,or grant° of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any ap le c e ora dinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature 6f 015)617 Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of �W heatj�idge COMMLJ]NiTy DEVELOPMENT Building & Inspection Services 7500 W. 29'h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a)ci.wheatridge.co.us I FOR OFFICE USE ONLY I Date: Plan/Permit # 0 Plan Review Fee: 11 Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 2'R70 U P4Arrn S'T VIA -W .9-tD4F_1 co ga335 Property Owner (please print): DAIIJ CT•RAN "[ A M An/ Phone: 720 • Z`q ( • 3S5�S Property Owner Email: 0TJC;-55 @)&mort1.. Cd('1 Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer: RoeAL'T C *4'CKF;2 / WALL -T" Klaslcc (3t9f�WAGKE.CZ1@ �pti41� - Govt, '60S. 35-9 . 7580 Architect/Engineer E-mail: W"®' Phone: IV$ . 422 , 105 Contractor Name: COLOQ.ADO SWV-0001 A►sn �J I OJDO W City of Wheat Ridge License #: 207J�'�i Phone: 303. 7 1,5.07%7 Contractor E-mail Address: -�Oem Q � a sv►-1900M . Cor" For Plan Review Questions & Comments (please print): CONTACT NAME (please print): tAAQ-TI W J;_Z Phone: 0-7 7? CONTACT EMAIL(p/ease print): ,jpEM &_cc>LeoaA70o_S'UPe00w1. Conn Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: C£C Plumbing: Mechanical: W.R. City License # 7 /'� QW.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields. ❑COMMERCIAL ® RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. JWXYACD of "\ZFZ. wiU- 3E :T-0S2AU-1n16,T- 06-W SvNago>v.. - AWLcnium, r-rl.�j GrL. S 112-00V � arb � f3`t ov2�S iA� vws , ST�I.L N 3 ��f-,�zi � oQ P-4N�w (o" 6s�wc2�z S Vs~a A lPl¢.o� +00s.F. fjS,tJ St. -w " owe w r f ( Bt -'fis.0 1^170 ft-110sF Sq. Ft./LF 400SF BTUs Gallons Amps Squares For Solar: Kw # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRATOR) or �HORIZED REPRESENTATIVE NE f- (0W�R)j (CONTRACTOR) Signature (first and last name): !Z DATE: I!� I q Printed Name: J DF- tAA Q,%J 4 DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: 0'25 Ry� CONSTRUCTION TYPE: v"5 Reviewer: BUILDING DEPARTMENT COMM NTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: lal Building Division Valuation: RESIDENTIAL Buildiny- Permit — Plan Review Worksheet Address: ZA70 (,cam l�ber�✓L S f Lot Size: lq, 02-1 6010,t950 sq. ft. Zoning: TZ --1 Lot Width: !. V ID ft. Rev. 09/2017 Property in the flood plain? t)Q If yes, notify PW Floodplain Administrator and add surveying condition FLD Subdivision: Any conflict? (Y/N) Related Cases: Type of project (applicable survey conditions in parenthesis): Maximum Lot Coverage: 7-5 % Existing Improvements (footprints): House: 2040, sq. ft. Shed: sq. ft. Detached garage: boo sq ft. Other: sq. ft. Total Existing -2-6516 sq. ft Lot Coverage 14,f) % 31 5-v5. Z5 sq. ft. Proposed Improvements (footprints): House/addition: 2 Lt5$ sq. ft. Shed: sq. ft Detached Garage: 600 sq. ft. Other: sq. ft. Proposed+Existing 3, p5'9 sq. ft Lot Coverage Z 1 S % Required Setbacks: R _ ®� S L5 401A Provided Setbacks: FR X SI f ercisf` ---t 1, 5' R �6 r :1K For additions or new construction, is the structure within 2 feet of minimum setbacks?IJ(2 If yes, add surveying condition FND. Maximum Height: 35 ft. Maximum Size: sq. ft. Proposed Height: vJ0.5 (u�fi+iM) ft. �. � X kb t c35' Proposed Size: sq. ft. Does the bulk plane apply? (Y/N) �Jo If yes, does it meet on all sides (Y/N): FR S S R (See 26-642 and 26-120.C.1 — applies to all single-family structures (new, addition, accessory) in R -IC and R-3) Parkland Conditions Does the permit result in a new dwelling unit (new structure or conversion from non -res use)? Q0 If yes, have parkland dedication fees already been paid (eg with a previous land use approval)? If fees are owed, add condition PFEE, notify owner, notify building division, enter fee amount in ADG. Rev. 09/2017 Streetscape Conditions Does the permit result in any of the following conditions? ❑ Construction of new roads ❑ Platting of new lots ❑ New development ❑ Additions that increase gross floor area (not just the footprint) by 60% or more (proposed floor area — existing floor area ) / existing floor area = % increase If any box above is checked... For SF/DUPLEX—Is there existing ❑ Curb ❑ Gutter L15 -ft+ sidewalk adjacent to the property? If curb, gutter or sidewalk is missing, streetscape construction or fees -in -lieu will be required. MULTIFAMILY—Does the frontage meet current city standards? If not, streetscape construction or fees -in -lieu will be required. Fees -in -lieu of dedication or construction are due at the time the permit is issued. Access Conditions (apply to all new driveways, garages, additions, or new homes/units) ICFor one and two-family dwellings, the first 25' of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. ❑ For all uses other than one and two family dwellings, no vehicle entrances or exits may be closer than 25' to any property line, except when used as joint access for two or more lots. C"In residential zone districts, curb cuts shall be at least 10 feet and not more than 24 feet in width. ❑ One and two-family dwellings may have horseshoe driveways, provided that the street accesses are at least 30 feet apart, measured from the interior edges. ("For all uses, one access point per property is permitted. Landscaping Conditions (apply to additions and new dwelling units) ❑ For one -and two-family dwellings, one tree for every 70 feet of street frontage is required. t Frontage of lot 100 b - width of driveway t- W$ ) / 70 = '?__ (round up for required trees) Street trees required: Z Street trees provided: 3 ❑ 100% of the front yard and 25% of the entire lot must be landscaped prior to issuance of C.O. ❑ In the event that landscaping cannot be installed due to inclement weather prior to the issuance of a C.O., an escrow agreement with financial guarantees may be allowed to ensure future installation. 125% of the cost of the proposed improvements will be required with the agreement. These funds will be reimbursed back to the property owner or contractor once the improvements are in place. Dwelling Unit ❑ Not approved as an independent dwelling unit. City of Wh6at Ridg OMMUNiTy DEV UN This form must be signed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Subco acto °sin rants and license must be up to date prior to permit issuance. Project Address: Permit #: General Contractor: �0C,6 -A OG S �ti ' [ O OUJ Electrical Sub -Contractor Company Name: State License #: Phone #• 30 S • (2i1 -ZS Master #: Wheat Rid a License #: (required field) l Z 'ZGZGti Signature ofprized Agent Dat Plumbing Sub -Contractor Company Dame: State License #: Wheat Ridge License #: Signature of Authorized Agent Mechanical Contractor Company Name: Phone #• Master #: _(required field) Date Phone: Wheat Ridge License #: (required field) Signature of Authorized Agent Date MY SitePlan Site Plaits When You Need Them Reviewed for Zoning Compliance by the ► +, City of Wheat Ridge Planning Division lye APPROVED+N1 C-041`'�oKg y;-' BY: Zit DATE: t-21 O I COMMENTS: Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. Landscaping removed or damaged during construction must be replaced prior to final inspection. Upham St 100' 14' _ 10' TDriveway 34' 16'-10" Eaves Ine 31' w � 53' 3, Eaves line — 19 —146' Fence Li 22' Line Eavac lino I — 8' - 35' - Line of Wall House 14' ------ 24, - -- Garage 16'-3" 25'25' Line of Wall 3'-5"- 4' Line of Wall g� Line Line of Wall S 12 54' — -------------- - �inefWall 27'7 -- -------- t ; 59' 34' — aves line_— �-`I �8 23'-10" v, m _ ► 1T '� 146' Property Line Lit R j ge COMMUNfrY t)LvkL0PMENI APPROVED Revie edfor Code Compliance zlaf�-Ig Plan miner Date Widltr of arM ' 7H! itSriaue o�p P~ w rOrnl ns of f speclkanora ono oomputot,ons shaN not be o perrn(t fo ,won opproval of any vgfabon to ony of Me prows oft of Me Owldk g code or q Cyy adJ pennMa prerummg to glue 0whorfty to Wok& or cancer the provisions of the swft coda or other or&_,jM of tMGtySW not be MIA 5'-10" Prooertv Line 2970 Upham St Land:0.32 AC Wheat Ridge, CO 80033 USA House:2058 SF scale: 1":20" EXTRV ALUMINUM RIDGE BEAM 69 70 73 EXTR'D ALUMINUM RIDGE 47 EXTR'D ALUMINUM ROOF MUNTIN GAP EXTR'D ALUMINUM ROOF MUNTIN 53 EXTR'D ALUMINUM GLAZING GAP 54 EXTR'D ALUMINUM SAVE END GAP EAVE CLIP EXTRV ALUMINUM ` 3" EAVE TRIM 5" SAVE TRIM W/ MOUNTING ANGLES EXTR'D ALUMINU WALL BAR 8 ROLLED ALUMINI. GUTTER EXTRIP ALUM NU EAVE TOp 27 EXTRb ALUMINUI EAVE BOTTOM NOTE: SAVE COULD AL50 BE 24 25 26 EXTR'D ALUMINUM EXTR'D ALUMINUM -L GL05ED 51LLO OR EXTENDED 51U(D STD. 501-11) KIGK PANEI OR GLA55 KICK PANEL SLIDING WINDOW --- 150METPIC VIEW NOTE= I. 5EE GENF-PAL-03 THROUGH GENERAL -06 P2AWIN65 E012 ITEM NUM6E125. NTE! CALCULATIONS SHALL BE PREPARED BY A DESIGN PROFESSIONAL AND SUBMITTED TO THE BUILDING OFFICIAL DEMONSTRATING THE DESIGN SNOW LOADS DO NOT EXCEED THE ALLOWABLE ROOF SNOW LOADS SPECIFIED ON THE PLANS. AND THAT CALCULATIONS SHALL ADDRESS THE SNOW LOAD PREVISION OF IBC SECTION 1608 INCLUDING, BUT NOT LIMITED TO, RAIN -ON -SNOW SURCHARGE LOAD, UNBALANCED SNOW AND SNOW DRIFT. (AC 340 SECTION 5.5) OPTIONAL - DUAL 5LIDING WINDOW (A5 VIEWED FROM OUTSIDE) EXTR'D ALUMINUM GABLE ADD-ON 41 —EXTR'D ALUMINUM 3" GLAZING BARO O 3" HEAVY BAR 5" GLAZING BAR 3B 39 5" HEAVY BAR 50LIP PANEL/ GLA55 PANELS EXTRb ALUMINUM68 69 BEAM P05T EXTRb ALUMINUM O UTILITY "H" EXTRIP ALUMIWM GLO5ED 511- b EXTR'D ALUMINU UTILITY GOV 2A EXTRIP ALUMINUM UTILITY H-GHANNEIO (MODELS 9DN-19DN) EXTRID ALUMINUM 90 DEG CORNER(: 230 SUN � 5AI25 CATHEDRAL MODEL IApMO EVALUATION REPORT R01 10 50LID OR (FIXED GLA55) TRAPEZOID PANEL TYPICAL E20NT ELEVATION KIGK PANEL — OPTIONAL REVERSE 5LIDING WINDOW OR TO L A5 VIEWED FROM OUTSIDE) c"`1 at Wheat Ridg Building Divi 411111 E- tr P4 i' -P4 Q 00 P;, w wz w c � Z Cn z z o U) CD r�q El P4 �a W � ww z0 U 0�LT, CD 0. CO W O L Q O REV. No.I DATE I BY IA2-16-14 2-16-14 RD 1 12-31-15 RD 2 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-01 01 OF 19 I I FT. FRONT WALL ELEVATION 12'-10" [391.16cm] 13FT. FRONT WALL ELEVATION ALL WINDOWS GAN 6E 51NGLE SLIDING OR DUAL 5LIDING. 4LUMINUM, GENTREX, 9LA55 KIGK5, AND GON5ERVAWALL ARE OPTIONAL. STUCCO KIGK5 ARE 5TANDARD. +� I I L I tHl9 un E v v In 3'-0' 3'-0' 4'-0" O 5LIDER 5LIDER SLIDER ND ND NDOW O 0 PANEL 3' KICK PANE 3' KICK PANE FEE] I5-5 7/8" 1472.12cm1 15FT. FRONT WALL ELEVATION ROOM MODEL FRONT WALL WIDTH RIDGE HEIGHT 0-0" 11'-0" FRONT WALL G'-0" 9'-3" SLIDER 13'-0" FRONT WALL SLIDER 9'-7" WINDOW 15'-0" FRONT WALL WINDOW 10'-0 1/4" 12'-10" [391.16cm] 13FT. FRONT WALL ELEVATION ALL WINDOWS GAN 6E 51NGLE SLIDING OR DUAL 5LIDING. 4LUMINUM, GENTREX, 9LA55 KIGK5, AND GON5ERVAWALL ARE OPTIONAL. STUCCO KIGK5 ARE 5TANDARD. +� I I L I tHl9 un E v v In 3'-0' 3'-0' 4'-0" O 5LIDER 5LIDER SLIDER ND ND NDOW O 0 PANEL 3' KICK PANE 3' KICK PANE FEE] I5-5 7/8" 1472.12cm1 15FT. FRONT WALL ELEVATION 17-2 1/2" 1524.51cm1 17FT. FRONT WALL ELEVATION 4'-0" SLIDER 5BT4 R/N 5'-0" SLIDER WINDOW 4'-O" KICK PANEL II Ill 5'-O" KICK PANEL 5BT4 UH I 4AT4 UH E 0 N 5!-(Y' 4 O" m 5LIDER SLIDER WINDOW MNDOW r 0 5'-0" KICK PANEL 4'-O" KICK PANEL 19-3 3/4" 1568.65cm] 19FT. FRONT WALL ELEVATION 5'-0° KICK PANEL 5'-O' KICK PANEL I 5-0" KICK PANEL 21'-5" 1652.75cm1 21FT. FRONT WALL ELEVATION 6'-0' KICK PANEL 11E5' -O' KICK PANEL 5'-0' KICK PANEL I FEI--!L� r23'-5" [713.74cm1 - 23FT. FRONT WALL ELEVATION 5ERIE5 230 501\1 E 5TAR5 CATHEDRAL MODEL GONEIGURATION ROOM MODEL FRONT WALL WIDTH RIDGE HEIGHT 4'-0" KICK 11'-0" FRONT WALL 10'-10" 9'-3" 17-2 1/2" 1524.51cm1 17FT. FRONT WALL ELEVATION 4'-0" SLIDER 5BT4 R/N 5'-0" SLIDER WINDOW 4'-O" KICK PANEL II Ill 5'-O" KICK PANEL 5BT4 UH I 4AT4 UH E 0 N 5!-(Y' 4 O" m 5LIDER SLIDER WINDOW MNDOW r 0 5'-0" KICK PANEL 4'-O" KICK PANEL 19-3 3/4" 1568.65cm] 19FT. FRONT WALL ELEVATION 5'-0° KICK PANEL 5'-O' KICK PANEL I 5-0" KICK PANEL 21'-5" 1652.75cm1 21FT. FRONT WALL ELEVATION 6'-0' KICK PANEL 11E5' -O' KICK PANEL 5'-0' KICK PANEL I FEI--!L� r23'-5" [713.74cm1 - 23FT. FRONT WALL ELEVATION 5ERIE5 230 501\1 E 5TAR5 CATHEDRAL MODEL GONEIGURATION ROOM MODEL FRONT WALL WIDTH RIDGE HEIGHT PROJEGTION FROM WALL 11'-0" FRONT WALL 10'-10" 9'-3" SEE NOTE I 13'-0" FRONT WALL 12'-10" 9'-7" 5EE NOTE 1 15'-0" FRONT WALL 15-5 7/8" 10'-0 1/4" 5EE NOTE I 17-0" FRONT WALL 17'-2 1/2" 10'-3 3/4" 5EE NOTE I 19'-O" FRONT WALL 19'-33/4" 10'-7 7/8" 5EE NOTE 1 21'-0" FRONT WALL 21'-5" 111-0 1/8" SEE NOTE 1 23'-0" FRONT WALL 23'-5" 11'-4 1/8" 5EE NOTE I NOTE: I. FOR PROJEGTION GONFIGURATION5 SEE DRAWING "3" FOR DIFFERENT WALL GONFIGURATION5. 2. ALL RIDGE HEIGHTS 8A5ED ON 81-15/16" EAVE HEIGHT. THESE HEIGHT5 GAN VARY WITH THE U5E OF TRAN5OM5 E DIFFERENT 51ZED KIGK PANE1-5. NOTE: ALL GLAZING 5U6JEGT TO GENERAL NOTE L.I.G. City of Wheat Ridge uild'+ng ���``�auu r u l l u+6 iriii _'vs115814 : cc slON P.,� O 0 51 Z w o ul Z U) Z x U) WE--, 9 pq ED pqPzC) -0 , r� u l Fi 0 W O Lo Q 0 n, REV. No. DATE I BY 1A2-16-14 2-16-14 RD 1 2N 2-31-15 RD REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH®02. ®2 of 19 30 5/8" 1 1/2" MIN. 2 11/16" 30 5/8" 30 5/8' 305/811 --305/5"— WITH NO WITH 30 5/8" 30 5/8" 30 5/8" GANEF GABLE END END UNDERSIDE OF EAVE s ELEV. 80 15/16" ALL WINDOWS CAN BE 51NGLE 5LIDING, DUAL SLIDING. OR FIXED T.O. SUB—FLOOR 0'-0" (DATUM) .39/16" WITH GABLE END ALUMINUM, GENTREX, AND GLA55 KIGK5 ARE OPTIONAL. 5T0000 KIGK5 ARE 5TANDARD 2 II/16" WITH GABLE END UNDERSIDE OF EAVE ELEV. BO 15/16" ALL WINDOW5 CAN BE 51NGLE 5LIDING, DUAL SLIDING. OR FIXED OIL T.O. SUB—FLOOR 0'-0' (DATUM) 39/16" WITH GABLE END ALUMINUM, GENTREX, AND GLASS KIGK5 ARE OPTIONAL. 5TUGG0 KIGK5 ARE 5TANDARD. 5-0" 2'-b" 2'-6 SLIDER FIXED FIXED WINDOW WINDOW WINDOW 5'-0" 2'-6" 2'-6„ GLA55 KIGK FIXED FIXED 1 3/4" 5-0" E> 5LIDING DOOR i! 5'-0" I' 6LA55 1RAN50M 5'-0" I 5'-0" II SLIDER SLIDER II WINDOW I WINDOW II 5-0'. GLA55 KIGK GLA -55 KIGK J / --__-- 1 3/4" �_59 1 /2" —� —59 1/2"---�59 1/2" �--59 1/2" 28 7/8"13/4" 28 7/8" 2 3/8" MIN. WITH NO 59 I/2" GABLE END OUT OF 51LL TO FACE OF WALL (5EE NOTE "I") A TYP. SIDE1/4-=l'—O-FORCONFIGURATION OPTIONS FOR 30-5/8 ROOF DAYS 36 5/8" 36 5/8" - OUT OF 51LL TO FACE OF WALL (5EE NOTE "I") B TYP. SIDE ELEVATION CONFIGURATION OPTIONS SCALE: 1/4"=V-0" FDR 36-5/8" ROOF DAYS 1 1/2" MIN WITH NO GABLE END 1'-0" AND 2'-0" TALL TRAN5OM5 ARE AVAILABLE A5 AN OPTION. NOTE: I. UNIT PROJECTION VARIES DEPENDING UPON NUMBER OF ROOF DAYS. DAY SPACING CAN BE 30 5/8" O.C. AND 36 5/8" O.C. 2. DIMENSION FROM C/L OF DAR TO OUTSIDE FACE OF SILL = 2 11/ I6" WITH GABLE END, AND 1 I/2" MINIMUM WITH NO GABLE END. 3. ALL RIDGE HEIGHTS ARE BASED ON 50-15/16" UNDER51DE OF SAVE HEIGHT. THESE HEIGHTS CAN VARY WITH THE USE OF TRAN5OM5 � DIFFERENT SIZED KICK PANELS. 4. STANDARD 51DE WALL CONFIGURATION CAN BE ANY COMBINATION AND QUANTITY OF OPTIONS SHOWN IN ELEVATION "A" � "B" r==____==_==� „ 6'-0" " 6LA55 TRANSOM " r--� -=-1 5LIDER II WINDOW II 6LA55 KIGK �- 71 1/2 — -� 2 3/8" MIN. WITH NO GABLE END 1'-0" AND 2'-0" TALL TRAN5OM5 ARE AVAILABLE A5 AN OPTION. cwy or Wheat Ridge REV. No. DATE BY A2-16-14 RD 12-31-15 RDI 2 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-03 03 OF 19 2'-1 1" 2'-1 1" 5LIDER FIXED FIXED WINDOW WINDOW WINDOW OUT OF 51LL TO FACE OF WALL (5EE NOTE "I") B TYP. SIDE ELEVATION CONFIGURATION OPTIONS SCALE: 1/4"=V-0" FDR 36-5/8" ROOF DAYS 1 1/2" MIN WITH NO GABLE END 1'-0" AND 2'-0" TALL TRAN5OM5 ARE AVAILABLE A5 AN OPTION. NOTE: I. UNIT PROJECTION VARIES DEPENDING UPON NUMBER OF ROOF DAYS. DAY SPACING CAN BE 30 5/8" O.C. AND 36 5/8" O.C. 2. DIMENSION FROM C/L OF DAR TO OUTSIDE FACE OF SILL = 2 11/ I6" WITH GABLE END, AND 1 I/2" MINIMUM WITH NO GABLE END. 3. ALL RIDGE HEIGHTS ARE BASED ON 50-15/16" UNDER51DE OF SAVE HEIGHT. THESE HEIGHTS CAN VARY WITH THE USE OF TRAN5OM5 � DIFFERENT SIZED KICK PANELS. 4. STANDARD 51DE WALL CONFIGURATION CAN BE ANY COMBINATION AND QUANTITY OF OPTIONS SHOWN IN ELEVATION "A" � "B" r==____==_==� „ 6'-0" " 6LA55 TRANSOM " r--� -=-1 5LIDER II WINDOW II 6LA55 KIGK �- 71 1/2 — -� 2 3/8" MIN. WITH NO GABLE END 1'-0" AND 2'-0" TALL TRAN5OM5 ARE AVAILABLE A5 AN OPTION. cwy or Wheat Ridge REV. No. DATE BY A2-16-14 RD 12-31-15 RDI 2 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-03 03 OF 19 i �A*CR Ilk AMmoA -- -- - - - - - - - - - - - OUT5IDE FACE WALL COLUMN (:D@ WALL EXISTING WALL (5EE NOTE 4, TYP COLUMN (@ 5TRUGTURAL N @ WALL COLUMN) (D © FRAMING) w 0 A B E F u IG IG 16 16 \J) TYP. TYP. I I TYP. TYP. VARIES - R 'oI z w � 5EE NOTE 3 SEE NOTE I 1 3/4" E NOTE 6 w t - O Z wl Lu s 5E Z O �I ------ ------ ------- I UTILITY 'H' UTILITY 'H' COLUMN O COLUMN O (SEE NOTE 5) D IG TYP. O O G IG - - - - - - - - - - - TYP. STANDAR 'H' COLUMN U (SEE NOTE 3, TYP) SEE NOTE 7 SEE NOTE 7 (TYP) i GOU MN ® CGOOLUMN 68 © IB ER IDGE 5EAM GOER GOU MN 5EE NOTE 3 C IG TYP. O OR —5EE NOTE 3 5EE NOTE 3 SEE NOTE I VARIES 13/4" OUTSIDE PAGE WALL SEE NOTE 6 DIMEN510 + 3 1/2" 2 3 VAKI ES x��U) x � �D E, o �x-4z �Z� w o In �z x�U) o H P4 Wo Z �o�w CD "u) O A O Lo A CATHEDRAL FLOOR PLAN Lj. SCALE=3/8"= I'-0" NOTE: I. DIM. TO OUT5IDE FACE OF WALL, 2. COLUMN 5PAGING VARIES DEPENDING UPON WINDOW E DOOR SIZES E CONFIGURATION. 6'-I 1/2" MAX. ON CENTER SPACING - 3. ACTUAL H- CHANNEL 15 SLIGHTLY LP -55 THAN 13/4';U51NG 1 3/4" IN GALGULATION5 OF WALL DIMENSIONS HELPS TO ACCOUNT FOR MANUFACTURING TOLERANGE5 IN WINDOW U AND DOOR DIMENSIONS. Z 4. IF H- CHANNEL 15 OMITTED EXPOSED WIDTH OF i11 GL05ED SILL 15 1 3/8" (THIS WILL NOT ALLOW FOR AN OUT OF PLUME HOUSE WALL). �r � 5. MINIMUM FILL WIDTH 1 1/8" (H -CHANNEL GUTTING Z TO GOPHER OR WINDOW/DOOR DIRECTLY INTO z CORNER). Q < 6. MINIMUM FOUNDATION PROJECTION REQ'D TO 3 O AGHEIVE DESIRED ANCHOR DOLT CAPACITY (FOR Q 12" GONGRETE FOUNDATION ONLY). C N 7. FOR FOOTING 51ZE E WHEN REQUIRED, SEE GENERAL -16 � GENERAL -17 FOR ALL POSTS EXCEPT RIDGE GEAM POST. 11] v SEE GENERAL -18 r GENERAL -19 FOR RIDGE GEAM POST. �[ 8. FOOTING TYPE MAY VARY, COORDINATE FOOTIN TYPE WITH DETAILS E CHARTS. city or WheatR;dga N, DATE BY guiidi �9 Divisor 1 2-16-14 RD 12-31-15 RD 2 \\,�}e�s;ttt;t�trrrrrr�� i REGfs`'�r,,, �$�:•• �•G • F•�'��''' REVIEWED BY: AS DWG. BY: RD 1814 ;� DATE: 1-10-11 •JOB #: -��••• '` •� •���� STARCATH-04 04 OF 19 A B QN 63" MAX (TYP) 14 14 A - - PAFTER BAR RAFTER BAR OUTSIDE FACE COLUMN n EXISTING WALL wz z z ? (@ ADEQUATE Lu w ~(ID © z z z z STRUCTURAL 3� 3�®3� g FRAMING) w RAFTER BAR RAFTER BAR 1- w A 0 0 ww Lu p 51M,TYP 51M,TYP z TYP SEE 3 3 3 3 Tyr,. NOTE 2 RAFTER BAR I I RAFTER BAR Ln Q oQ w w UTILITY 'H' z z z d) F F 1 6 wsl ~O COLUMN (TYP)O2 az 00 o � 51M,TYP Lu w RAFTER BAR u RAFTER BAR _ UTILITY 'H' - - - - - - - - COLUMN (TYP) WLn C t' `n w w cV `s) o 13 - m 17- T TYP RAFTER BAR RAFTER BAR cj Ln (nLn 10 W 5TANDARD 'H' v- 12 12 z _ o O COLUMN (TYP) �� ®��� ���� m _ >-w �� G w0 z O N �- RAFTER BAR �-VARIES- VARIES - RAFTER BAR - - �� w� I E i- m z >® o Q� 51M,TYP Q D w `n CORNER w� z RIDGE BEAM z Q �o �� WLuCOLUMN (TYP) z z COLUMN z �az zo(m -Z RAFTER BAR RAFTER BAR GABLE ADD -0 41 GABLE ADD-ON I E Lu I A 41 51M,TYP H I I 15 I 0 z w w 5EE NOTE 3 SEE NOTE 3 SEE NOTE 3 5EE NOTE 3 SEE NOTE I I I SEE NOTE I VA IE5 I 2 3 4 5 connninl/` PI ANI A.I �/a"_0 n" NOTE: I. DIM. TO OUTSIDE FACE OF WALL. 2. WALL SECTIONS VARY DEPENDING UPON MODEL CONFIGURATION. SEE SHEETS 6 THRU 10 FOR ADDITIONAL OPTIONS. 3. COLUMN SPACING VARIES DEPENDING UPON WINDOW e DOOR SIZES E CONFIGURATION. 6'-1 1/2" MAX. ON GENTER SPACING. 4, 5EE PAGE 27 "FLOOR PLAN" FOR NOTES NOT SHOWN. 5. 30 5/5" E 36 5/8" BAY SPACING VARIES DEPENDING ON ROOM MODEL. 6. FOR ADDITIONAL OPTION5 SEE SHEET 12. 7. ALL ROOF SECTION REFERENCE DETAILS WITH 3" GLAZING BAR5. 5" GLAZING BAR5 INSTALLED IN SAME MANNER - SEE EXT2U510N SHEETS ON "GENE DRAWINGS" FOR ADDITIONAL INFO LZ 'S C,. p: dr o,. i Oin c9co x��Da H �x-z 0 0 U) w o U) Z Q 6 ,4z x�U) W o PpMzTC) O Fv/ ox�,w o w0 � Q REV. No.I DATE I BY A2-16-14 R 12-31-15 RD REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-05 05 of 19 cy z CN z Q 0 � � N c -N _ LIQ Q REV. No.I DATE I BY A2-16-14 R 12-31-15 RD REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-05 05 of 19 NOTE! THE ADJU5TABLE EAVE 15 5HOWN. 5EE 5PECIFIG EAVE DETAILS FOR THE CORE5PONDN6 MODELS. EXTR'D ALUMINUM EAVE TDP (A.7EB) EAVE BOTTOM (A•7ET8)�w//2n ID #8 x 1/2" TEK SCREW #8 x 1/2" TEV SCREW @ 12" O.G. (7-150) @ 12" O.G. (7.150) (TYP. ALL ELEVATIONS) (TYP. ALL ELEVATIONS) EXTR'D ALUMINUM EXTR'D ALUMINUM EAVE TOP (A.7ED) EAVE TOP (A -7E8) EAVE BOTTOM (A*7ET8) SAVE BOTTOM (As7ETB) 11 f/���y --,, F ••...••...•� ��� STARCATH®06 NOTE! THE ADJU5TABLE EAVEI5 SHOWN. 5EE SPECIFIC EAVE DETAILS FOR THE GORE5PONDIW MODELS. Ln 1 #B x 1/2" TEK SCREW n@ W' o.G. (7-150) l` ;TIONS )RAWING5 of IONS MU5T 8E DETERMINED DY A DESIGN PROFESSIONAL. A SOLID KICK PANEL -WINDOW NOT TO5CALE 6 NO TRANSOM (FX MODEL) LLI > Q i1J LL - 0 w CN Lu n z 0 CID I #8 x 1/2" TEK SCREW- @ 16" O.G. (7*150) O (TYP. ALL ELEVATIONS) n Z - U cc)� (V SHIM __j CV � �8Y INSTALLER II T FOR DETAILS A 8 NOT SHOWN 5EE 16 16 #8 x 1/2" TEK SCREW @ 12" O.G. (7-150) (TYP. ALL ELEVATIONS) NOTE! THE ADJUSTABLE SAVE 15 5HOWN. 5EE 5PECIFIG EAVE DETAILS FOR THE CORE5PONDIN6 MODEL5. @816" IO.G.TEK (7 .550)EW` J 111 _ z � D- -co 11 FOR DETAILS A 8 NOT SHOWN SEE16 16 NOT TO SCALE A 22" GLASS KICK PANEL -WINDOW NOT TO5CALE A I I "SOLID KICK PANEL- 12" GLASS KICK C NO TRANSOM (FX MODEL) 6 WITH WINDOW NO TRANSOM (FX MODEL) - 1� UJ in x P o Q Q O l--1 P4 F4 P4 0�z�' W O W o U) U) zo�U) O) EE- pq � o w w as z rw �oow 'nxU)P�, CD w 0 L Q II IJEV. No.1 DATE BY /A 2-16-14 RD 1 12-31-15 RD ��`tttttutt+L)ur \\��LV\®® V\®®11/�'A�``/ d/ °�P�G�f�"s�tcdx''� REVIEWED BY: AS f �A t � DWG. BY: RD _ = 15814 .. DATE: 1-10-11 . a �'%�,�°•� •'�4'0 JOB#: 11 f/���y --,, F ••...••...•� ��� STARCATH®06 ®6 of 19 n8 x 1/2" TEV. SCREW @ 12" O.G. (7t 150) (TYP. ALL ELEVATIONS) EXTRb ALUMINUM - EAVE TOP (A°7EB) EAVE BOTTOM (A°7ET8) NOTE! THE ADJ1.15TABLE EAVE 15 SHOWN. SEE SPECIFIC SAVE DETAILS FOR THE GORE5PONDIN6 MODELS. 57 '00 iQ _(y A 12" SOLID KICK PANEL -WINDOW NOT TO5CALf 7 12" GLASS TRANSOM (FH MODELS) k8 x 1/2' TEK SCREW @ 12" O.G. (7-150) (TYP. ALL ELEVATIONS) EXTR'D ALUMINUM - EAVE TOP (A°7ED) EAVE BOTTOM (A°7ET8) NOTE! THE ADJU5TABLE EAVE 15 SHOWN. SEE 5PECIFIC EAVE DETAILS FOR THE COpaPONDIN6 MODELS. 0 �Q 12" SOLID KICK PANEL -WINDOW NOT TO5CALE 712" GLASS TRANSOM (FH MODELS) lAp a ® Q L�L1 x H P4 O Q w x p0 u P4 Hxxwz z Q P4o�z� O W W 0 01 `f) rj) C/) Z -4 Zz z Q4 0 o ��P4 w� c w pa z0 �0 0xwo a on moi• o,„ Lo A A Q L�L1 �n z n z Q 0 �c N 01 �L �. C on moi• o,„ REV. No. DATE BY . . iN� CO RD 1 A2-16-14 12-31-15 RD (3 RE612 REVIEWED BY: AS DWG. BY: RD 15$14 = DATE: 1-10-11 JOB#: gyp:, il�/y�1�i e`er STARCATH-07 "IfImm 10 Fo % of 19 NOTE! THE ADJUSTABLE EAVE 15 51-10WJ. SEE 5PEGIFIG EAVE DETAILS FOR THE GORESPONDING MODE15. EXTR'D ALUMINUM— EAVE TOP (A*7EB) EAVE BOTTOM (A-7ETB) 0 Lo EXTRV ALUMINUM - 4B x 1/2" TEK SCREW EAVE TOP (A-7EB) @ 12" O.G. (7-150) EAVE BOTTOM (A-7ET5) (TYP. ALL ELEVATIONS) A SOLID KICK PANEL -WINDOW NOT TO5CALE g 12" GLA55 TRANSOM (FT MODELS) co 95 x I/2" TEK SCREW EXTR'D ALUMINUM— EAVE TOP (A-7EW @ a' O.G. (7-150) EAVE BOTTOM (A-7ETB) (TYP. ALL ELEVATIONS) NOTE! THE ADJUSTABLE SAVE 15 5HOt4N. SEE SPECIFIC EAVE PETALS FOR 1}E GORE5PONDNG MODELS. co #B x 1/2" TEK SCREW @ 12" O.G. (7+150) (TYP. ALL ELEVATIONS) A 22" GLA55 KICK PANEL -WINDOW NOTT05CALE g 12" GLA55 TRAN50M (FT MODELS) PUK Ur- IAIL.S NOT SHOWN 5EE16 1 6 A I I " SOLID KICK PANEL -1 2" GLASS KICK g WITI1 WINDOW11 2" GLASS TRANSOM NOT ToscALE (FT MODELS) � i (/] x P- pi O 0 co X d z O 0 Z U) � W � O U)z A z -eo�U' H W.w-� wo z �o0w c:) x ul O W O Lo A Q --A o � co z � Q o C�s (-v >� Q C o Lu ks) REV. No.I DATE I BY IA2-16-14 2-16-14 R 1 12-31-15 RD 2 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-08 48 x 1/2" TEK 5GREW @ 12" O.G. (7-150) EXTRb ALUMINUM (TYP. ALL ELEVATIONS) EXTR'D ALUMINUM tl EAVE TOP (A -WB) EAVE TOP (A-7EB) #B x 1/2" TEV 5GREW U] co _ EAVE BOTTOM (A-7ETB) EAVE BOTTOM (A-7ETB) @ 12" O.G. (7+150) - E- x ,--� P: NOTE! (TYP. ALL ELEVATIONS) CJ d+ W � x�`D0 THE ADJUSTABLE EAVE 15 SHOWN. R Q ti N O SEE 5PEGIFIG EAVE DETAIL5 FOR O O THE G0RE5PONDIN6 MODEL5. _ P' a � � z �o� - O >1z W o w o Ct) mzq� Z TTzP4 o�co _ _ ��P4x �o �� w pqmzw NQ NQ co O H N N Lo CD x W 0 , D oO A O C� LL C) O z O z Lll #5 x 1/2" TEV 5GREW = lll #B x I/2" TEK 5GREW S > O @ 16" O.G. (7-150) Q @ 16" O.G. (7-150) � Lu (TYP. ALL ELEVATION5) _ (y w n (1YP. ALL ELEVATIONS) _ v LL C) jw p �w Lu w n Nv n -(-4 ll1 ►v U n ow n oW D — D — ~ Z � cc) co 0 o Q O 111 � \ Lu Q �y D- �� dt c0 SHIM J �• BY IN5TALLER O%s) moi' REV. NDDATE BY N J A2-16-14 RD N N 12-31-15 RD ���;etVtililtE?Iflf,i!1!/���/ 2 ✓jF/i N w i 'o REVIEWED BY: AS DWG. BY: RD etre $14 • FOR DETAILS A B FOR DETAILS A B �-�:� 15 :a== DATE: 1-10-11 1( y/�� %�, NOT SHOWN SEE 16 I � NOT St10WN SEE 16 16 ���� :. JOB#: ` STARCATH-09 A 22 GLASS KICK PANEL—WINDOW /f`��� ��� �� A SOLID KICK PANEL—WINDOW NOT TO SCALE 11 ION g 22" GLASS TRANSOM NOTTO SCALE g 22" GLASS TRANSOM 09 OF 19 EXTR'D ALUMINUM EAVE TOP (A.7EB) EAVE BOTTOM (A.7ETB) 95 x 1/2" TEV SGREW @ 12" O.G. (7.150) (TYP. ALL ELEVATIONS) NOTE! THE ADJU5TABLE SAVE 15 SHOWN. 5EE SPECIFIC EAVE DETAILS FOR THE CORE5PONDIN61 MODELS. BY OTHERS )R 5ERVAWALL KXX FOR VIATION) :TED FILL 11. A BASE WALL -WINDOW NOT TO 5CALE I O 12" TRANSOM (BASE WALL MODEL BT) EXTR'D ALUMINUM- EAVE TOP (A.7ED) EAVE BOTTOM (A.7ETB) BY OTHERS �R 5ERVM FOWR� FOR DETAILS `J MTION) NOT SHOWN SEE16 I G A \ BASE WALL -WINDOW NOT TO SCALE w u\/l \ LL 0 W #8 x 1/2" TEV SCREW (-- Z @ 16" O.G. (7.150) _ I O NO TRANSOM (BASE WALL MODEL BX) .ATED FILL IM. A BASE WALL -WINDOW NOT TO5CALE I O 12" TRANSOM (BASE WALL MODEL BH) ft 6 G. v : 15814 /���••• 'r e• P CR N AV ifltN!I4tttt 1 P4 U) ~'L r- P4 � &- 0 d r4 d Z Z W 0 U) -:4 z w0�P4 w�D o;� Ln U) O w 0 Lo Q z C� z < 0 cy N cv cl\ _ cv REV. No.I DATE I BY IA2-16-14 2-16-14 RD 1 12-31-15 RD I REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-10 10 OF 19 ;#8 x 1/2" TEV SGREW 08 x 1/2" TEV SCREW @ 12" D.G. (74150) @ 12" O.G. (7.150) EXTR'D ALUMINUM (TYP. ALL ELEVATIONS) (TYP. ALL ELEVATIONS) SAVE TOP (A47E6) EAVE BOTTOM (A.7ETB) NOTE! NOTE! TI -E ADJU5TA5LE SAVE 15 SHOWN. SEE 5PEGFIG EAVE DETAILS FOR THE ADJUSTABLE EAVE 15 SHOWN. c0 10 THE GORE5PONDING MODEL5. 5EE 5PECIFIG SAVE DETAIL5 FOR THE CORE5POMING MODEL5. BY OTHERS �R 5ERVM FOWR� FOR DETAILS `J MTION) NOT SHOWN SEE16 I G A \ BASE WALL -WINDOW NOT TO SCALE w u\/l \ LL 0 W #8 x 1/2" TEV SCREW (-- Z @ 16" O.G. (7.150) _ I O NO TRANSOM (BASE WALL MODEL BX) .ATED FILL IM. A BASE WALL -WINDOW NOT TO5CALE I O 12" TRANSOM (BASE WALL MODEL BH) ft 6 G. v : 15814 /���••• 'r e• P CR N AV ifltN!I4tttt 1 P4 U) ~'L r- P4 � &- 0 d r4 d Z Z W 0 U) -:4 z w0�P4 w�D o;� Ln U) O w 0 Lo Q z C� z < 0 cy N cv cl\ _ cv REV. No.I DATE I BY IA2-16-14 2-16-14 RD 1 12-31-15 RD I REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-10 10 OF 19 EXTR'D ALUMINUM --- GLAZING CAP (A'5GC) GLAZING CORD (RK5NGL) #10 x 1 112" S.S. MACHINE 5CREW (HN2004) W/ THERMAL BUSHING (CN4201) @± 10" O.C. MAX. EXTR'D ALUMINUM 3'RAFTER BAR (A'5L33) (SHOWN) 3' HEAVY RAFTER BAR (A'5HB3) SAVE CLIP (CN 13004) / III G'THK. GLAZING) TAPE (HK IO09ACR) EXTR'D ALUMINUM --- UTILITY COVER (A'5GT) EXTR'D ALUMINUM ELECTRIC SAVE (A7' 144) GLAZING BEAD (A7'134) EXTR'D ALUMINI SLIDER HEAD (/ EXTR'D ALUMINUM BEAUTY CAP (A -413C) EXTR'D ALUMINUM GABLE ADD-ON (A' 12GO w � D � N 12° GLASS O E)(TR'D ALUMINUM - 5UDER 51LL (A -75Q #8 x 1/2" TEK 5CREW @ I G' O.C. (7-150) MT. ALL ELEVATION5) EXTR'D ALUMINUM— WINDOW JAMB (A7' 133) EXTRD ALUMINUM— WINDOW JAMB (A7-131) EXTR'D ALUMINUM— CLOSED 51LL (A -7C5) In SLIDER X p d� WINDOW n - -11 DATE: 1 10 ��•o j(�y��, JOB#: ®ate\ ® co Q p Z N w mO 1 OF 19 O o I'_ D Z LL_ 0 a- 0 LL_ Ln 22' KICK 14- 11_1 PANEL — N O o 0 — w NW D Lu mo 6 co FOR DETAIL5 m` NOT SHOWN SEE 1 6 I G A GABLE END WALL SECTION NOT TO SCALE EXTR'D ALUMINUM — GLAZING CAP (A'45GC) GLAZING CORD - (RK5NGU #IOx I I/2°5.5. ::""�� MACHINE 5CREW (HN2004) W/ THERMAL BU5HING (CN4201) @.t 10" O.C. MAX. ALUMINUM 3' HE I 3" HEAVY RAFTER BAR I (A-5HB3) I/ I G" THK. GLAZING - TAPE (HK I009ACR) EXTR'D ALUMINUM - UTIUTY COVER (A'5GT) EXTR'D ALUMINUM --- ELECTRIC SAVE (A7' 144) GLAZING BEAD (A7'134) EXTR'D ALUMINUM — 5UDER HEAD (A-7HD) EXTR'D ALUMINUM - 5UDER SILL (A'75L) # 10 x 1/2' TEK 5CREW @ I G' O.C. (7-151) OYP. ALL ELEVATIONS) EXTR'D ALUMINUM WINDOW JAMB (A7'133) EXTR'D ALUMINUM WINDOW JAMB (A7'13 1) FOR DETAILS A � NOT 511OWN 5EE 6 A FRONT WALL SECTION 5 NOT TO 5CAli EXTR'D ALUMINUM —�_ CL05ED SILL (A'7C5) EXTR'D ALUMINUM BEAUTY CAP (A'413C) EXTRD ALUMINUM GABLE ADD-ON (A' 12G5) D o U o z D D Ln O Z_ w O D_ o N w _Uwe UPJ—i�= vg�=m 0 — of � : N N a-/ Lu J N N Z W 0 < Q WEEP HOLE. PLASHING BYIN5TALLER BY OTHERS FOR DETAIL5 A B NOT SHOWN 5EE Q:6 6 GABLE END WALL SECTION w/ 5TD. OR CUSTOM GLASS TRAP % Of Wheat Ridge U2 ul O -+ F O Z Z W O U) Z U) Z Zx�ri) H P4 P4 W O O H 0 x U) w C WO � A REV. No. DATE BY A16-14 RD 12-31-15 RD R 9G1 REVIEWED BY: AS DWG. BY: RD 1 x$14 :a - : - -11 DATE: 1 10 ��•o j(�y��, JOB#: ®ate\ ® STARCATH-11 1 OF 19 �-1 1/2" RUBBER NO GABLE END FLA5HING (RK45689) EXTR'D ALUMINUM BEAUTY CAP (A+413G) EXTR'D ALUMINUM GLAZING GAP (A45GC) GLAZING GORE) (RK5NGL) 7/8"IN5ULATED GLA55 #10 x 1 1/2" 5.5. MACHINE SCREW (HN2004) W/ THERMAL B1-15HIN6 (GN4201) @± 10" O.G. MAX. 1/2" SHIM (BY OTHERS) EXTR'D ALUMINUM 3" RAFTER BAR (A451-53) (SHOWN) 3" HEAVY RAFTER BAR (A 45H[53) A NO GABLE END SECTION 12 SCALE: G" = P -O" �--1 112 " -- A NO GABLE END SECTION 12 SCALE: G" = I' -a' RUBBER NO GABLE END FLASHING (KK45G89) EXTR'D ALUMINUM BEAUTY CAP (A'413C) EXTR'D ALUMINUM GLAZING CAP (A'5GC) GLAZING CORD (RK5 NGL) 7/8" IN5ULATED GLA55 #lox 1 1/2"5.5. MACHINE 5CREW (HN2004) W/ THERMAL BUSHING (CN4201) @± 10' O.C. MAX. 1/2" SHIM (BY OTHEK5) EXTR'D ALUMINUM 3" HEAVY RAFTER BAR (A'5HB3) EXTR'D ALUMINUM BEAUTY GAP (A*413G) EXTR'D ALUMINUM GLAZING GAP (A+5GG GLAZING GORE) (RK5NGL) 7/8" IN5ULATED GLA55 410 x 1 1/2" 5.5. MAGHINE 5GREW (HN2004) W/ THERMAL BU5HING (GN4201) @*- 10" O.G. MAX. EXTR'D ALUMINUM 3" RAFTER BAR (Aa5LB3) (SHOWN) 3" HEAVY RAFTER BAR (A o5HB3) B 3" RAFTER BAR SECTION 12 SCALE: G" = I' -O" EXTR'D ALUMINUM BEAUTY CAP (A'45C) EXTR'D ALUMINUM GLAZING CAP (A'5GC) GLAZING CORD (RK5NGL) 7/8"INSULATED GLA55 #10x 1 1/2"5.5. MACHINE 5GREW (HN2004) W/THERMAL BUSHING (CN4201) @± 10" O.G. MAX. EXTR'O ALUMINUM 5" RAFTER BAR (A>5LB5) (SHOWN) 5" HEAVY RAFTER DAR (A«5GB5) B 5" RAFTER BAR SECTION 12 SCALE: G" = P -o" EXTR'D ALUMINUM BEAUTY CAP (A'4BC) EXTR'D ALUMINUM GLAZING CAP (A'5GC) GLAZING CORD (RK5 NGL) 7/8"IN5ULATED GLA55 # 10 x 1 112" S.S. MACHINE SCREW (HN2004) W/ THERMAL BUSHING (CN4201) @± 10" O.C. MAX. EXTR'D ALUMINUM 5" HEAVY RAFTER BAR (A°5GB5) I 11 1/4" x 1 1/4" SELF THREADING 5GREW (HN20130) I I I @t 9" O.G. TO 5EGURE I IRAFTER 5TIFFENER TO BAR I OPTIONAL I I EXTR'D ALUMINUM I RAFTER 5TIFFENER (Ax4R5B) l q�l EXTR'D ALUMINUM RAFTER STIFFENER COVER (A°4GR) 511 RAFTER W/4R5B STIFFENER SECTION r� SCALE: G" = I' -I" G. EXTR'D ALUMINUM I BEAUTY CAP (A'413C) EXTR'D ALUMINUM GLAZING CAP (A'5GC) GLAZING CORD (RK5NGL) 7/8" INSULATED GLA55 #10x 1 1/2"5.5. MACHINE 5GREW (HN2004) W/ THERMAL BUSHING (CN4201) @± 10" O.C. MAX. EXTR'D ALUMINUM 5" HEAVY RAFTER BAR (A.5GB5) TR'D ALUMINUM I' BEAM IN5ERT 5GBI) B 5" RAFTER W/5C131 5TIFFENER SECTION 5CAI F: G" = P-0` Ali 'A, CnYof 'heat R;69e <1 a' U] x � P4 x v-- P4 O E-1 O �x�z p Zul w o U) Z Q � Z Ia� O � U1 H lYi�'� pq W W O O CD O W O to Q 0 R Q IzI^^ UA �J F- Lu z � z \s) Q O U N W °tom REV. Nod DATE I BY IA2-16-14 2-16-14 RD 1 12-31-15 RD 2 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH®12 12 OF 19 #8 x 1/2" TEK SCREW (1-17-150) @ 12" O.G. MAX. #10 x 1 3/4" SCREWS (HN2 1 1 1) INTO BAR SCREW B055 EXTR'D ALUM LADDER SUPPORTS CNLADCLP EXTKD ALUMINL MUNTIN CAP (A' EXTR'D ALUMINL 3" RAFTER BAR (A'51-53) (SHOV (3" HEAVY RAFT (A'51183) OPTIC A5 REQ'D BY LC EXLR'D ALUMINUM — EAVE END CAP (C'81 I SILICONE SEALANT - (BY OTHERS) EXTR'D ALUMINUM WALL BAR (A'GWBB) SETTING BLOCKS (HK 1023) WEEP HOLE BY INSTALLER UNIVERSAL GUTTER (A'K5G) FXLR'D ALUMINUM 3" SNAP-ON GUTTER FASCIA (A'3GFG) WEEP HOLE BY INSTALLER EXTKD ALUMINUM FIXED EAVE (A'7E3B) A 3" SAVE DETAIL 13 5CALe: G'= I' -Q' INSULATED EXTR'D ALUMINUM GLAZING CAP (A'5GC) ood� 1 Owe- 10-24 x 3/8" SCREW (HN201 1) GLAZING CORD (RK5 NGL) ;'D ALUMINUM TIN (A'4MT6) ING TAPE D09) 7/5" INSULATED GLASS I/IG"THK. GLAZING TAPE (HK I009ACR) EXTKD ALUMINUM LAVE TRIM (A'7MT) #8 x 112- TEK SCREW (7-150) 4 PER CLIP CLIP ANGLE (I -5R -AC) EXTR'D ALUMINUM SAVE CLIP (CN 13004) # 10 x 1 1/4" TEK SCREW (H -202G) 5 PER CLIP # 10 x 1 1/4" TEK SCREW (H -202G) @EACH GLAZING BAR EXTKD ALUMINUM 3" RAFTER BAR (A'51-63) (SHOWN) (3" HEAVY RAFTER BAR (A'5HB3) OPTIONAL AS REQ'D BY LOADING) #8 x 112" TEK SCREW (7' 150) @ 12" O.C. CKD55 MUNTIN DETAI #8 x 1/2" TEK SCREW (1-17-150) @ 12" O.G. MAX. #10 x 1 3/4" ^ EXTKD ALUMINUM — GLAZING CAP (A'5GC) EXTKD ALUMINUM — EAVE END CAP (C'81 I SILICONE SEALANT (BY OTHERS) EXTKD ALUMINUM— WALL BAR (A'GWBB) SETTING 13LOCK5--\ (HK 1023) WEEP HOLE J BY INSTALLER EXTKD ALUMINUM — 5" LUMINUM- 5" SNAP-ON GUTTER FASCIA (A'5GFG) WEEP HOLE BY INSTALLER EXTKD ALUMINUM— FIXED SAVE (A'7E3B) EXTR'D ALUMINUM MUNTIN CAP (A'4MX13) 10-24 x 3/4" MACHINE SCREW (HN2008) WITH THERMAL BUSHING (CN4201) RUBBER MUNTIN COVER (A'4MI) EXTR'D ALUMINUM 3" RAFTER BAR (A'503) (SHOWN) (3" HEAVY RAFTER BAR (A'5H53) OPTIONAL AS REQ'D BY LOADING) 7/8° INSULATED GLA55 I/ I G" THK. GLAZING TAPE (H K I 009ACR) FXTR'D ALUMINUM SAVE TRIM (A'55T5) #8 x 112" TEK SCREW (7-150) 4 PER CLIP CLIP ANGLE (I -SR -AC) EXTR'D ALUMINUM WE CLIP (CN 13004) # 10 x 1 1/4" TEK SCREW (H -202G) G PER CLIP # 10 x 1 1/4" TEK SCREW (H -202G) @EACH GLAZING BAR EXTKD ALUMINUM 5" RAFTER BAR (A'51-135) (SHOWN) (5" HEAVY RAFTER BAR (A'5065) OPTIONAL AS REQ'D BY LOADING) ALUMINUM SHIM (C' 13003) #8 x 112" TEK SCREW (7-150) @ 12" O.G. U) xP4 a �D O .iL-,O w H P4 Ix O0Z� W O :�! W O U) V) (71 ZZ z El W, P4 P, W �) ww z0 U) 0OU�" P4 CD �D O q ME G7 dAe REV. No. DATE BY Vvr n� r A 2-16-14 RD 1 12-31-15 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-13 13 OF 19 EXTR'D ALUMINUM RIDGE (A'BFRG) SILICONE SEALANT W/ BACKER ROD (BY OTHERS) # 10-24 X 3/8" SCREW (H'2008) \ FXTR'D ALUMINUM — RIDGE COVER (A'7MT) EXTR'D ALUMINUM RIDGE COVER (A'4RC7) #IOx I 1/4"TEK SCREW (H'202G) I/ I G" GLAZING TAPE (HK 1009ACR) THREADING SCREW (H'2080) (FOUR PER. CLIP) FXfR'D ALUMINUM 2x2x1/4' RIDGE CLIP (CN 1303 1) (ATHOUSE WALL) `- AM ALUMINUM 15E DBEAM (A'7TB) FOR BEAM SUPPORT X POST SEE A 7" RIDGE BEAM @ EXISTING STRUCTURE 14 NOT TO 5CALE ' FOR DETAILS A B NOT SHOWN SEE 1 rj I rj EXTR'D ALUMINUM 12" BEAM SUPPORT CLIP (CN7207) TRIM 2 3/8" OFF THE ENDS OF THE GUTTER TRACKS FOR PROPER FIT EXTR'D ALUMINUM 12" BEAM (503 12) 5 - 3/8" X 3" THRU-BOLT W/ NUT aQ EXISTING STRUCTURE (HDW 10085) B 12" RIDGE BEAM 1 4 Nor TO SCALE FOR DETAILS A NOT SHOWN SEE 8 X SECTION "X" NG :TURF VA EXMD ALUMINUM BEAM (A'7TB) - STEEL TUBE INSERT (CN7144) MAKE SURE THAT STEEL IS PRIMED BEFORE INSTALLED TO PREVENT ELECTROLOSIS. 3/8'x 1 7/8" ALUMINUM SHIM FIT TIGHT WITH G" MINIMUM BEARING BY OTHERS C 7" RIDGE BEAM w/STEEL INSERT 14 NOT TO 51ALE FXfR'D ALUMINUN 3" GLAZING BAR 6 3" HEAVY BAR (A' 1/4"x 1 1/4"SELF THREADING SCRE (H'2080) TWO Of ONE 51DE OF ARC EXTR'D ALUMINUN BEAM (A'7TB) "DGE SPLICE (CN 3001) 15E5 A 4GMA INSIDE BAR) 4" x 1 1/4" SELF TREADING SCREW (H'2080) SUR ON ONE SIDE OF ARCH DIAL Z SECTION "Z -Z" DGE CLIP :N 13002) 4'x I 1 /4' SELF HREADING SCREW 1.2080) (FOUR PER CLIP) E- x i x O Q O E-1 O P4 z P-, ' q P� f P4 0 >-, z c4 coW O W O Y) �,zQU) Z O U] z Oyu' O W E, P-' W � ww z� U) 0 H FTS P4 o W O �D In Gl U It:I REV. No.I DATE I BY 1A2-16-14 2-16-14 RD 1 12-31-15 NO REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH m 14 14OF19 V VILE DEHIVI P05T CLIP (CN 13005) 7TB = -------------- RIDGE BEAM x U) m 0 TOP OF UTILITY',' o�z� x @ END O 2 5/8" WALL I I I I I I 1 I I I I _ 5 L CUTOUT I I I I I I I I I I I I I I p04 w I I I I I j I I I I I I I NO 00 I I I I N J I I I 4- 3/8" X 1 1/4" I I I I BOLT (HDW 10082) - SUPPORT I I I P05T BEAM I I I -- --- (VARIES) I I I CL05ED SILL I III III I 3 - 1/4" X 1 1/4" (A -7C5) o I III III 5CREW (HN2080) In TYPICAL EACH CLIP l� I 1 II 11 I I (G) TOTAL n n I PLAN VIEW LLIk P05T CLIP SECTION @ RIDGE P05T CLIP (CN 13005) (CN 13005) BEAM 12-31-15 RD �F T BEAM P05T— (713P OR 7TB DEPENDING ON LOAD CONDITIONS) PLAN @ COLUMN UTILITY'H' FOR CONNECTION @ FOUNDATION 5EE B 15 JAMB OF GLA55 TRAPEZOID TRAN50M5 4-#10X 1 1/4"SCREW (HN202G) THRU ELECTRIC "H" INTO P05T AND SUPPORT BEAM @ 10" OC A POST TO 7" BEAM CONNECTION DETAIL 15 NOT TO 5CALE 5CB12 SUPPORT BEAM TOP OF UTILITY 'H' @ END WALL I I I I I I 2 =GABLE PKI P05T m �o r I I P05T 3- 1/4' X 1 1/4" 5CREW UTILITY "H" (713P) (HN2080) TYPICAL EACH 1 CHANNEL CLIP 1 I I #8 X 112" TEK SCREW (H7'150) @ IOO.C. VERTICALLY (TYPICAL) WITH POST IN5TALLED i O@ i O O POST CLIP POST CLIP (CN 13006) (CN 13006) USE ON IF REQ'D 13 POST BASE DETAILS I NOT TO 5CALE %b- I 6 � a a � x U) H2 0 � O O (O o�z� x O w w O U)z Aul z :4 z O co p04 w U w z O w 0w LD U] Cu P4o w O LCA Q O Q z � z ks) Q N Q LLIk REV. No. F DATEBY 2-16-14 RD 1 12-31-15 RD 2 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STAR CATH -15 15 OF 19 I 0 UT5IDE INSIDE OF = ROOM ROOM uj _.._i.._.. .._.._.._.._.. d-_- FLASHING - (BY OTHERS)-/ 14 I f � m -51LIGONE SEALANT BY INSTALLER #8 x 1/2" TEV 5GREW (H7*150) @ 16" O.G. MAX. EACH 51DE EXTR'D ALUMINUM GLO5ED 51LL (A47G5) 2x6 DEGKING OR 3/4" PLYWOOD FLOOR SHEATHING (TO BE EVALUATED BY A DESIGN PROFE5510NAL) MINIMUM GONNECTION5 ARE SHOWN ON DRAWING 17, 18, E 19.. DOUBLE 2X6 J015T ROOM PERIMETER G= .42 (MINIMUM) (TO BE EVALUATED BY A DE516N P12OFE5510NAL) 2X BLOCKING G= .42 (MINIMUM) IF REQUIRED FOR LAGS. (TO BE EVALUATED BY A DESIGN PROFE5510NAL) �--UNIT WIDTH / LENGTH NOTE: B 1. 5EE FOR ALTERNATE 16 DETAIL5 2. CONNECTION TO FOUR 5EA5ON5 "GON5ERVA DEGK" SAME A5 5HOWN A 51 LL TO DECK CONNECTION DETAIL 16 NOT TO SCALE —2 1/2" MIN. LASHIN51DE� OUT5IDE OF = kD OF ROOM w ROOM = ING z (8Y OTHERS) 5TRUGTURAL CONCRETE 5LA8 MINIMUM OF 2500 psi (TO 8E EVALUATED BY A DF -51( PROFE5510NAL) MINIMUM GONNEGTION5 ARE 5HOWN ON DRAWING 17, 18, E 19. 1 3/4" 3/4" 1 FOUNDATION UNIT WIDTH / LENGTH -1 PROJECTION FOR DETAIL5 A NOT SHOWN 5EE 16 B SILL TO CONCRETE SLAB CONNECTION DETAIL 1 6 NOT TO 5CALE NOTE: CONT. EXTR'D ALUMINUM CONNECTION CLOSED SILL (A -7C5) BELOW @ EAVE SIMILAR EXTR'D ALUMINUM IL WINDOW JAMB (A7'131 U) I NSI DE ROOM (H7*150) 51X AT EACH WITH 5GHEDULE) #8 x 1/2" TEK SCREW (7" 150) OUT5IDE FACE OF EIGHT AT EACH CORNER EXI5TING 5TRUGTURE EXTR'D ALUMINUM CORNER COLUMN m (A'7C9) - 3 1/2" EXF05ED �_ MINIMUM GONNEGTION5 PLAN VIEW ARE 5HOWN ON DRAWING 17, 18, f 19. C CORNER P05T CONNECTION AT 51LL 1 G NOT TO SGALE NOTE: CONNECTION @ EAVE 51MILAR PI ANI VFW 2 7/8" THK. WALL PANEL EXTR'D ALUMINUM UTILITY COVER (A•56T) #8 x 1/2" TEK 5GREW (H7* 150) 51X AT EACH COLUMN EXTR'D ALUMINUM UTILITY H-GOLUMN (A7.145) EXTR'D ALUMINUM WINDOW JAMB (A7+131U) CONT. EXTR'D ALUMINUM CL05ED SILL (As7G5) D UTILITY H -CHANNEL CONNECTION AT SILL G NOT TO 5CALE Ll i u� o i IL INSIDE ROOM VERTICALLY (COORDINATE (H7*150) 51X AT EACH WITH 5GHEDULE) WALL (SHOWN) OR EXTEN510M OUT5IDE FACE OF EACH COLUMN EXI5TING 5TRUGTURE 2 7/8" THK. WALL PANEL m i I i n - 3 1/2" EXF05ED �_ MINIMUM GONNEGTION5 PLAN VIEW ARE 5HOWN ON DRAWING 17, 18, f 19. C CORNER P05T CONNECTION AT 51LL 1 G NOT TO SGALE NOTE: CONNECTION @ EAVE 51MILAR PI ANI VFW 2 7/8" THK. WALL PANEL EXTR'D ALUMINUM UTILITY COVER (A•56T) #8 x 1/2" TEK 5GREW (H7* 150) 51X AT EACH COLUMN EXTR'D ALUMINUM UTILITY H-GOLUMN (A7.145) EXTR'D ALUMINUM WINDOW JAMB (A7+131U) CONT. EXTR'D ALUMINUM CL05ED SILL (As7G5) D UTILITY H -CHANNEL CONNECTION AT SILL G NOT TO 5CALE APPLY GAULKIN 2 LAG BOLTS @ TOP 6" OF =r:AVE51MILA12 COLUMN 5PAGE @ 3" O.G. VERTICALLY E @ 30" o.c. INSIDE ROOM VERTICALLY (COORDINATE (H7*150) 51X AT EACH WITH 5GHEDULE) WALL (SHOWN) OR EXTEN510M OUT5IDE FACE OF EACH COLUMN EXI5TING 5TRUGTURE 2 7/8" THK. WALL PANEL (@ 5TRUGTURAL 48 x 1/2" TEK 5G12EW FRAMING) 51'11. H-GOLUMN (A7* 111) APPLY GAULKIN --EXTR'D ALUMINUM BETWEEN 51LL E WALL @ EAVE 51MILAR CL05ED 51LL (A*7G5) 08 x 1/2" TEK SGRE PLACED VERTICALLY AGAIN5T (H7*150) 51X AT EACH WALL (SHOWN) OR EXTEN510M COLUMN EACH COLUMN 511-1- (A*7X5) 2 7/8" THK. WALL PANEL 48 x 1/2" TEK 5G12EW EXTR'D ALUMINUM 51'11. H-GOLUMN (A7* 111) (H7o 150) @ 16" O.G. 5TD. H-GOLUMN (A7a111) ARE SHOWN ON DRAWING 1\ i EACH 51DE VERTICALLY EXCEPT AT TOP 9" NOTE: F PLAN VIEW PROVIDE 3 EACH SIDE I. 5EE FOR ALTERNATE (5PAGE 3" O.G.) 16 DETAIL5 EXTR'D ALUMINUM WINDOW JAMB (A7#131U) E GABLE ATTACHMENT AT HOU5EWALL w/WINDOW 1 6 NOT TO SCALE 48 x 1/2" TEK (H7# 150) @16' MAX. VERTICALI FOR DETAILS NOT SHOWN 5E', PLAN VIEW 2 7/8" THK. WALL PANEL f GA13LE ATTACHMENT AT HOU5EWALL w/SOLID PANEL 6 NOT TO 5CALE NOTE: GONNEGTION @ EAVE 51MILAR INSIDE ROOM 5" 48 x I/2" TEK 5GREW (H7a150) 51X AT EACH COLUMN 2 7/8" THK. WALL PANEL EXTR'D ALUMINUM 51'11. H-GOLUMN (A7* 111) MINIMUM GONNEGTION5 I ARE SHOWN ON DRAWING 1\ i 17, 18, E 19. PI ANI \/IF\A/ G H -CHANNEL CONNECTION AT 51LL I G NOT TO SCALE ��eataid9e co O - F o co cn ul Z z O6 ul co EW-��•� PEI O z � a0CD 0 ul CD A O Lo REV. No.I DATE I BY 2-16-14 RD 12-31-15 RD fel REVIEWED BY: AS DWG, BY: RD DATE: 1-10-11 JOB#: STARCATH-16 16 OF 19 HOUR 5EA50N5 5UN1200M5 230 5UN E STAIz5 CATHEDRAL DESIGN 11\12\ Vas 90 MPH WIND LOAD EXP. 6 (2006) (2000 IPG/15G � 2012 IRG Vulf 115 MPH WIND LOAD EXP. 5 (2012) 15G, (2015) 113CA2G � 2016 G5C LOAD: 20 P5F / V3s 90 MPH WIND LOAD EXP. 6 (2006) (2009) IRG/160 � 2012 IRG LOAD: 20 P5F / Vult 118 MPH WIND LOAD EXP. 6 (2012) IBG, (2015) IBG/IRG £ (20 16) GBG POOH PITCH : 4 ON 12 LOAD: 60 P5F / V3s 90 MPH WIND LOAD EXP. 6 (2006) (2009) IRG/16G + 2012 IRG cr- i � i..i} i i s &er)u WIN IF) i non GUD R (')n i?) IFS(; ('7n 15) IF5G/1120 E (20 16) LOAD: 40 P5F / V3s 90 MPH WIND LOAD EXP. 6 (2006) (2009) IRGADC, E 2012 IRG LOAD: 40 P5F / Vult 118 MPH WIND LOAD EXP. 8 (2012) 16C. (2015) 160/IRG E (2016) CDC OPTION WALL I ROOF FRAMING CONFIGURATION EAVE TO P05T RAFTER TO SAVE FRONT WALL LENGTH, FT. CLIP TO RIDGE FRONT WALL LENGTH, FT. FRONT WALL LENGTH, FT. II' 13' PROJEGTION, FT. 11' 13' 15' 17' 19' 21' 23' II WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WA -P2 -GI -12I 12 WA -PI -CI -RI WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WA -PI -CI -RI WA -P2 -GI -RI 13 WA -PI -GI -121 WA -PI -CI -RI WA -PI -CI -121 WA -P I -G I -R I WA -PI -GI -121 WA -PI -CI -121 WA -P2 -G 1-121 15 WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -R2 WA -PI -GI -R2 WA -P2 -GI -22 16 WA -PI -GI -RI WA -PI -GI -121 WA -PI -GI -RI WA -PI -GI -22 WA -PI -GI -122 WA -PI -GI -123 WA -P2 -GI -123 19 WA -PI -GI -122 WA -PI -GI -22 WA -PI -GI -123 WA -PI -GI -123 WA -PI -GI -123 WA -PI -GI -R3 WA -P2 -GI -123 21 WA -PI -GI -123 WA -PI -GI -123 WA -PI -CI -R3 WA -PI -CI -123 WA -PI -GI -23 WA -PI -CI -R3 WA -P2 -GI -123 22 WA -PI - I-123 WA -P I -G I -R3 WA -PI -GI -R3 WA -PI -GI -R3 WA -PI -CI -R3 WA -PI -GI -R3 WA -P2 -G1 -R4 23 WA -PI -Cf -2.3 WA -P I -C I -R3 WA -P I -G I-123 WA -P I -G I-123 WA -P I -G-123 WA -PI -GI -R4 WA -P2 -G 1-124 LOAD: 40 P5F / V3s 90 MPH WIND LOAD EXP. 6 (2006) (2009) IRGADC, E 2012 IRG LOAD: 40 P5F / Vult 118 MPH WIND LOAD EXP. 8 (2012) 16C. (2015) 160/IRG E (2016) CDC LOAD: 80 PSF / V3s 90 MPH WIND LOAD EXP. 6 (200(D) (2009) IRG/16G E 2012 IRG r,cr i v_u iia nnu Ull in I nAr) CYU Ll (teal-)) IP,('. (7nl5) 113(:/1120; E (2016) GDC OPTION WALL E ROOF FRAMING CONFIGURATION P05T TO SILL EAVE TO P05T RAFTER TO SAVE FRONT WALL LENGTH, FT. CLIP TO RIDGE FRONT WALL LENGTH, FT. I I' 13' 15, 11 19' PROJEGTION, FT. II' 13' 15' 17' 19' 21' 23' 11 WA -PI -GI -RI WA -P I -C I -R I WA -P I -G 1-121 WA -P I -G I -R I WA -P2 -GI -21 WA -P2 -GI -RI WA -P3 -G I -R 1 12 WA -PI -GI -R] WA -PI -GI -121 WA -PI -GI -RI WA -PI -CI -RI WA -P2 -G 1-121 WA -P2 -G 1-122 WA -P3 -G 1-122 13 WA -P I -G 1-121 WA -PI -GI -R1 WA -PI -GI -IRI WA -P I -G I -R2 WA -P2 -G 1-122 WA -P2 -GI -122 WA -P3 -G 1-123 15 WA -PI -CI -R2 WA -P I -C 1-22 WA -PI -GI -R2 WA -P I -G 1-123 WA -P2 -GI -R3 WA -P2 -G 1-123 WA -P3 -GI -R3 16 WA -PI -GI -R2 WA -PI -GI -23 WA -PI -GI -123 WA -PI -GI -123 WA -P2 -GI -R3 WA -P2 -GI -123 WA-P3--GI-R3 19 WA -PI -GI -123 WA -PI -GI -23 WA -PI -GI -R3 WA -PI -GI -R3 WA -P2 -GI -23 WA -P2 -GI -R4 WA -P3 -GI -124 21 WA -PI -CI -23 WA -PI -GI -R3 WA -PI -GI -Q4 WA- P I -G I -R4 WA -P2 -G 1-123 WA -P2 -G 1-124 T WA -P3-6 1425�Qr 22 WA -P I -G 1-123 WA -P I -G 1-124 WA -PI -CI -Q4 WA -P I -G I -R4 WA -P2 -C 1-124 ;:TINA -P2-G 1 -R5 -:i -.f- 23 WA -PI -GI -R4 WA -P I -G I -R4 WA -PI -GI -R4 t WA -P I -G 1-R5tfit"z` ;WA -P2 -G l -R5 ;; =t > WA - 'P2 -G 1-125 _ WA -P3 G I-125; ' LOAD: 80 PSF / V3s 90 MPH WIND LOAD EXP. 6 (200(D) (2009) IRG/16G E 2012 IRG r,cr i v_u iia nnu Ull in I nAr) CYU Ll (teal-)) IP,('. (7nl5) 113(:/1120; E (2016) GDC OPTION WALL f ROOF FRAMING CONFIGURATION P05T TO SILL EAVE TO P05T RAFTER TO SAVE FRONT WALL LENGTH, FT. CLIP TO RIDGE FRONT WALL LENGTH, FT. I I' 13' 15, 11 19' PROJEGTION, FT. 1 1' 13, 15, 17' 19, 21' 23' 11 WA -PI -GI -IRI WA -PI -GI -121 WA -P I -C I -R I WA -P2 -CI -RI WA -P2 -GI -22 WA -P4 -G I -R3 WA -P4 -G 1-123 12 WA -PI -GI -IRI WA -PI -CI -RI WA -PI -CI -122 WA -P2 -C, 1-122 —WA -P2 -r_ 1-123 WA -P4 -GI -R5 WA -P4 -C 1-123 13 WA -PI -GI -R2 WA -PI -GI -122 WA -PI -GI -23 WA -P2 -CI -123 WA -P2 -GI -123 WA -P4 -GI -123 WA -P4 -GI -123 15 WA -PI -GI -123 WA -PI -GI -R3 WA -PI -GI -123 WA -P2 -GI -R3 WA -P2 -GI -R3 WA -P4 -GI -R3 WA -P4 -GI -R4 16 WA -PI -GI -R3 WA -PI -GI -123 WA -PI -GI -R3 WA -P2 -GI -R3 WA -P2 -GI -123 WA -P4 -GI -R4 WA -P4 -CI -24 19 WA -PI -GI -123 WA -PI -GI -123 WA -PI -GI -124 WA -P2 -GI -124 WA -P2 -GI -124 t (6)#10 UTILITY POST 21 WA -PI -GI -124 WA -PI -01-124 WA-PI-CI-124?WA-P2-G1-RWA-P2-G1-125; ;AWA-P4-G1-R5YWA-P4-G1-125`;,= _ 22 WA -PI -CI -124 WA -PI -GI -124 'KWA-PI-GI-R5Sw AWA-P2-GI-125.%.r;WA-P2-GI-RSs = WA-P4-GI-R5c S WA -P4 -GI -125?«; 23 WA -PI -GI -124 < ' _ _' _ .z?•:WA PI GI R5:':..,,.;WA-PI-GI-125>• _s r.'.� .-..2-GI-RS's WA-P2-GI-RS'us>`;s'^'WA-P4-GI-RSis` >;WA -P4 -G1-125 _.WA P LOAD: 80 PSF / V3s 90 MPH WIND LOAD EXP. 6 (200(D) (2009) IRG/16G E 2012 IRG r,cr i v_u iia nnu Ull in I nAr) CYU Ll (teal-)) IP,('. (7nl5) 113(:/1120; E (2016) GDC CONNECTION OPTIONS OPTION WALL e ROOF FRAMING CONFIGURATION P05T TO SILL EAVE TO P05T RAFTER TO SAVE FRONT WALL LENGTH, FT. CLIP TO RIDGE PROJECTION, FT. I I' 13' 15, 11 19' 21 23 II WA-PI--GI-121 WA -PI -CI -RI WA -P2 -GI -R2 WA -P2 -GI -R3 WA -P4 -GI -R3 WA -P4 -CI -R3 WA -P4 -CI -R3 12 WA -PI -GI -R2 WA -PI -GI -R2 WA -P2 -GI -123 WA -P2 -GI -R3 WA -P4 -GI -R3 WA -P4 -GI -R3 WA -P4 -GI -123 13 WA -PI -GI -R2 WA -PI -GI -123 WA -P2 -GI -123 WA -P2 -GI -R3 WA -P4 -GI -R3 WA -P4 -GI -123 WA -P4 -CI -24 15 WA -PI -GI -123 WA -PI -GI -R3 WA -P2 -CI -R3 WA -P2 -GI -R3 WA -P4 -CI -R4 WA -P4 -GI -R4 _ WA -P4 -GI -125. GI WA -P4 -GI -25 z 16 WA -PI -GI -123 WA -PI -GI -R3 WA -P2 -GI -R3 WA -P2 -GI -124 WA -P4 -GI -124 WA -P4 -125 GL i::; AWA -GI -125=. 19 - -124 1 WA PI -G I WA -PI -GI -124 ^zWA-P2 GI -1253:' `='iWA-P2-GI-RSt >1NA-P4-GI-125 4? WA -P4 -RS -P4 21 WA -PI -CI -R4 m.. _ -� - WA-P2-GI-125;`•ft;�;WA-P2-GI-125�A+�`WA-P4-GI-125,,;,�_�!:WA-P4-GI-R5��,��;'�(WA-P4-GI-125;;-1 WA -P I -G I -RS;;; ; r`< 22 AWA -P I -G-125' ,,,:, "^'`" WA-P-G-R5WA-P2 G I-125 .�,cWA-P2 G I RS�f-, .WA P4 G I RS,, :WA 23 �' > -PI-GI-125' ,"WA-P2-GI-R5e r=`WA-P2-GI-R5r: x ` .WA -P4 -GI -125 ti" WA-P4-GI-R5k .WA -P4 CONNECTION OPTIONS OPTION SILL TO FPM P05T TO SILL EAVE TO P05T RAFTER TO SAVE RIDGE CLIP TO RAFTER CLIP TO RIDGE GORNE12 COLUMN LITE "H" I UTILITY "H" I LITE "H741256 I UTILITY "H775P I ADJUSTABLE EAVE (2) 3/8" DIA. AT (8)#8 GORNE12 P05T (8)#8 CORNER P05T (4) #10 CLIP TO EAVE 5065 GI EACH P05T E 3/8" (6)#8 LITE P05T (6)#8 LITE P05T (I) #10 RAFTER TO EAVE (4) I/4" (2) 3/8" ® DIA. AT 16" O.G. (6)#8 UTILITY P05T (6)#8 UTILITY P05T (8) #10 CLIP TO RAFTER R2 7T6 WITH STEEL TU6E IN5ERT MAX. 12LW 124 12�W-4R�51D�� 125 (2) 3/8" DIA. AT (6)#10 CORNER P05T (8)#10 CORNER P05T (4) # 10 CLIP TO EAVE G2 EACH P05T E 3/8" (6)410 LITE P05T (6)#10 LITE P05T (1)#10 RAFTER TO SAVE (6) 1/4" (2) 3/8" DIA. AT 16" O.G. (6)#10 UTILITY POST (6)#10 UTILITY P05T (B) #10 CLIP TO RAFTER MAX. (2) 3/8" 4858 TO SILL (4) 1/4" 41258 TO RAFTER WALL FRAMING OPTIONS 70 DESIGNATION OPTION I 2 3 4 5 6 WACORNER COLUMN LITE "H"I UTILITY "H" LITE "H" UTILITY "H7713P I ADJU5TABLE EAVE WB GORNE12 COLUMN LITE "H" I UTILITY "H" I LITE "H741256 I UTILITY "H775P I ADJUSTABLE EAVE Notes: I. The ultimate (Vult) wind loading are a5 per 2012 IBC, 2015 IBC/IRC and 2016 CBG. 2. The V35 wind loading are a5 per 2006/2009 International Building Code 4� 2000/2009 International K651dential Code * 2012 IRC. 3. Shaded areas represents that steel ridge beam and post (to be de51gned by others) 15 required. _ Th15 summary pertaln5 to the structural Integrity of our unit up to, but not Including, the connectlon5 to the ex15t1ng structure and/or any new ;on5truction. All substructure de51gn requirements, and connectlon5 to the exlsting structure are not Included In the scope of work for the four seasons product and must be de5lgned by a local design profe551onal. 5. The values Indicated on the chart are for uniform I0ad5 and do not Include 5peclal load condltlon5 created by attachment to the existing structure. These may include snow drifting or unbalanced snow loading. Any 5peclal loading condltlon5 must be evaluated by a local de51gn profe551onal. city of Wheat Ridge �D x��o Q T+ 0 E O w wz Pa O�Z� �Hj w rn U W O U) �ZQU) z z P40� P4 W �D w �aaaz0 O zh W, U w z o W O � � Q O w REV. Nod DATE I BY IA2-16-14 2-16-14 RD 1 12-31-15 RD 2 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-17 17 OF 19 70 ROOF RAFTER SELECTION PI 5L63 P2 5H63 P3 51-65 P4 5065 P5 5065-5G61 P6 5G55-41256 ® RIDGE 6EAM SELECTION RI 7T6 R2 7T6 WITH STEEL TU6E IN5ERT 123 12LW 124 12�W-4R�51D�� 125 STEE city of Wheat Ridge �D x��o Q T+ 0 E O w wz Pa O�Z� �Hj w rn U W O U) �ZQU) z z P40� P4 W �D w �aaaz0 O zh W, U w z o W O � � Q O w REV. Nod DATE I BY IA2-16-14 2-16-14 RD 1 12-31-15 RD 2 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-17 17 OF 19 SOUP 5EA50N5 5UNPOOM5 230 5UN � 5TAR5 CATHEDRAL DE51GN 1 z Vas 110 MPH WIND LOAD EXP. G (2006) (2000 IRG/166 E 2012 IRG Vult 140 MPH WIND LOAD EXP. G (2012) 16G, (2015) 15GARG £ 2016 GE3G LOAD: 20 P5F / V35 110 MPH WIND LOAD EXP. G (2006) (2009) IRG/IBG 8 2012 IRG LOAD: 20 P5F / Vult 140 MPH WIND LOAD EXP. G (2012) 16G (2015) 16G/IRG + (2016) CDG ROOF PITCH : 4 ON 12 LOAD: 60 P5F / V35 110 MPH WIND LOAD EXP. G (2006) (2009) IRGADC 6 2012 IRG L_ LOAD: 60 P5F / Vult 140 MPH WIND LOAD EXP. G (2012) 16G (2015) IBG/IRG E (2016) GBG LOAD: 40 P5F / V35 110 MPH WIND LOAD EXP. G (2006) (2009) IRG/16G E 2012 IRG LOAD: 40 P5F / Vult 140 MPH WIND LOAD EXP. G (2012) IBC (2015) IBC/IRG � (2016) GBG OPTION WALL E ROOF FRAMING CONFIGURATION SAVE TO P05T FRONT WALL LENGTH, FT. PROJEGTION, FT. FRONT WALL LENGTH, FT. FRONT WALL LENGTH, FT. FRONT WALL LENGTH, FT. II' 13' PROJECTION, FT. II' 13' 15' 17' 19' 21' 23' 11 WA -P I -G I -R I WA -P I -G I -R I WA -PI -CI -RI WA -PI -GI -RI WB -P I -G2-121 WB -P I -G2-121 WD -P2 -G2-21 12 WA -PI -GI -121 WA -PI -GI -PI WA -PI -GI -121 WA -P I -C 1-121 WB -P I -G2 -R 1 WB -P I -C2 -R I WB -P2 -G2 -R I 13 WA -P I -G I -R I WA -PI -GI -121 WA -PI -CI -RI WA -P I -G I -R I W13 -PI -G2-121 WB -PI -G2-121 W13 -P2 -C2-121 15 WA -PI -GI -RI WA -PI -GI -121 WA -PI -GI -RI WA -PI -GI -RI WB -PI -G2422 WB -PI -G2-122 WB -P2 -G2 -R2 16 WA -PI -GI -21 WA -PI -GI -21 WA -PI -CI -R] WA -P I -G 1-122 WB -P I -C2-122 W13 -PI -G2-123 WB -P2 -G2 -R3 19 WA -PI -GI -R2 WA -PI -GI -R2 WA -PI -GI -R3 WA -PI -GI -23 W6 -PI -C2 -R3 WB -PI -G2-123 WB -P2 -G2 -R3 21 WA -P I -G 1-123 WA -PI -GI -123 WA -P I -G 1-123 WA -PI -GI -R3 WB -P I -G2 -R3 W13 -PI -G2 -P-3 WB -P2 -G2-123 22 WA -PI -GI -R3 WA -PI -CI -123 WA -PI -GI -R3 WA -P I -G 1-123 WB -P I -G2 -R3 WB-PI—G2—R,3 VJ13-P2-G2-R4 23 WA -PI -GI -123 WA -PI -GI -R3 WA -PI -GI -23 WA -PI -GI -23 WB -PI -C2-123 WB -PI -G2 -R4 WB -P2 -G2 -R4 LOAD: 40 P5F / V35 110 MPH WIND LOAD EXP. G (2006) (2009) IRG/16G E 2012 IRG LOAD: 40 P5F / Vult 140 MPH WIND LOAD EXP. G (2012) IBC (2015) IBC/IRG � (2016) GBG LOAD: 80 P5F / V35 110 MPH WIND LOAD EXP. G (2006) (2009) IRG/IBC E 2012 IRG LOAD: 50 P5F / Vult 140 MPH WIND LOAD EXP. G (2012) 13G, (2015) IBC/IRG f (2016) CBC :t OPTION WALL f ROOF FRAMING CONFIGURATION P05T TO 511-1- SAVE TO P05T FRONT WALL LENGTH, FT. PROJEGTION, FT. FRONT WALL LENGTH, FT. FRONT WALL LENGTH, FT. PROJECTION, FT.' II' PROJECTION, FT. II' 13' 15' 17' 19' 21' 23' II WA -PI -GI -121 WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WB -P2 -G2 -RI WB -P2 -G2 -12I WB -P3 -G2 -RI 12 WA -PI -Cl -IRI WA -PI -GI -IRI WA -PI -GI -PI WA -PI -CI -RI VV13-P2-G2-R I WB -P2 -G2 -R2 WB -P3 -G2-122 13 WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -R2 WB -P2 -G2 -R2 WB -P2 -G2 -R2 W5 -P3 -G2-122 IS WA -PI -GI -22 WA -PI -GI -122 WA -PI -GI -R2 WA -PI -GI -123 W13 -P2 -G2-122 WB -P2 -G2 -R2 W8 -P3 -G2 -R3 16 WA -PI -GI -122 WA -PI -GI -123 WA -PI -GI -23 WA -PI -GI -123 W13 -P2 -G2 -R3 WB -P2 -G2 -R3 W13 -P3 -G2-123 19 WA -PI -GI -123 WA -PI -GI -R3 NA -PI -CI -R3 WA -P I -G 1-R3 WB -P2 -G2 -R3 WB -P2 -G2 -R4 W5 -P3 -G2.124 21 WA -PI -GI -123 WA -PI -GI -123 WA -PI -GI -124 WA -PI -GI -124 WB -P2 -G2-124 WB -P2 -G2-124 :2 ?VJB-P3-G2-125.,,j_, 22 WA -PI -GI -R3 WA -PI -C,1-124 WA -PI -CI -R4 WA -P I -G I -R4 WB -P2 -G2-124: W6 -P2 -G2-125 �'- AWB -P3 -G2-125. 23 WA -PI -CI -R4 WA -PI -CI -124 WA -PI -CI -R4 WA -PI -GI -RSA AWB -P2 -G2-125 =•,hW6-P2-G2-R5iq`., ;AWB -P3 -G2 -RS's LOAD: 80 P5F / V35 110 MPH WIND LOAD EXP. G (2006) (2009) IRG/IBC E 2012 IRG LOAD: 50 P5F / Vult 140 MPH WIND LOAD EXP. G (2012) 13G, (2015) IBC/IRG f (2016) CBC :t OPTION WALL E ROOF FRAMING CONFIGURATION P05T TO 511-1- SAVE TO P05T FRONT WALL LENGTH, FT. PROJEGTION, FT. FRONT WALL LENGTH, FT. 13' 15' 17' 19' 21' 23' PROJECTION, FT.' II' 13' 15' 17' 19' 21 23 II WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -RI WA -P2 -GI -RI WB -P2 -G2 -R3 W8 -P4 -G2 -R3 WB -P4 -G2 -R3 12 WA -PI -GI -RI WA -PI -GI -RI WA -PI -GI -R2 WA -P2 -GI -R2 WB -P2 -G2-123 WB -P4 -G2 -R3 WB -P4 -G2 -R3 13 WA -PI -GI -R2 WA -PI -GI -122 WA -PI -G1-123 WA -P2 -CI -R3 WB -P2 -G2-123 WB -P4 -G2-123 WB -P4 -G2-123 15 WA -PI -GI -123 WA -PI -GI -123 WA -PI -GI -R3 WA -P2 -GI -R3 WB -P2 -G2 -R3 WB -P4 -G2-123 WB -P4 -G2-124 16 19 21 22 23 WA-PI-GI-123WA-PI-GI-123 WA -PI -GI -123 WA -PI -GI -124 WA -PI -GI -124 WA -PI -GI -124 WA -PI -GI -123 WA -P2 -CI -123 WB -P2 -G2 -R3 WB -P4 -G2-124 WB -P4 -G2-124 WA -PI -GI -23 WA -PI -CI -R4 WA -P2 -GI -124 j WB -1`2 -G2 -R4 >:-;WB-P4-G2-125;,-.= W6 -P4 -C2 -R50-- WA -PI -GI -124 WA -PI -CI -124 WA -P2 -GI -125 'z=WB-P2-G2-125- ;W6 -P4 G2-125 AWB -P4 -G2-1252,:; WA-PI-GI-124;WA-PI-GI-R5��-�y'�'WA-P2-GI-RSz?>' aWB-P2-G2-R5`':>`-M:WB-P4-G2-125 5 .fc;WB-P4-G2-125;''; WB-P2-G2-R5rr'r4V6-P4-G2-125:- "`'"WA -PI -GI -125 = `"WA -PI -GI -125 MWA-P2-GI-125 Y- - . - Fes` W6_P4 G2-RSr'': LOAD: 80 P5F / V35 110 MPH WIND LOAD EXP. G (2006) (2009) IRG/IBC E 2012 IRG LOAD: 50 P5F / Vult 140 MPH WIND LOAD EXP. G (2012) 13G, (2015) IBC/IRG f (2016) CBC :t CONNECTION OPTIONS OPTION WALL E ROOF FRAMING CONFIGURATION P05T TO 511-1- SAVE TO P05T FRONT WALL LENGTH, FT. PROJEGTION, FT. II' 13' 15' 17' 19' 21' 23' II WA -PI -CI -RI WA -PI -GI-RI WA -P2 -GI -122 WA -P2 -GI -R3 WB -P4 -G2 -R3 WB -P4 -G2-123 W5 -P4 -G2 -R3 12 WA -PI -GI -122 WA -PI -GI -122 WA -P2 -GI -R3 WA -P2 -GI -R3 WB -P4 -G2 -R3 WB -P4 -G2-123 WB -P4 -G2 -R3 13 WA -PI -GI -122 WA -PI -GI -R3 WA -P2 -GI -R3 WA -P2 -GI -R3 WB -P4 -G2 -R3 WB -P4 -C2 -R3 WB -P4 -G2 -R4 15 WA -PI -CI -r23 WA -PI -GI -123 WA -P2 -GI -R3 WA -P2 -G I-123 WB -P4 -C2 -R4 W8 -P4 -G2 -R4 .WB -P4 -G2-125 = r 16 WA -P I -G 1-123 WA -PI -GI -23 WA -P2 -CI -R3 WA -P2 -G 1-24 WB -P4 -G2 -R4 ^a WB -P4 -G2 125=:= :WB -P4 -G2- 19 WA -PI -GI -124 WA -PI -GI -124 WA -P2 -G1-125'' 'WA -P2 -G1 -RS:= ,.WB-P4-G2-R5yc.z";WB-P4-G2 125>':; -•+W8-P4 G2-125 21 WA -PI -GI -124 uWA-PI-GI-RS 4r:`•WA-P2-GI-R5 `' WA -P2 -GI -RS= ` 'NB-P4-G2-125;-q<`WB-P4-G2125 �; :." WB-P4G2-125 Y 22 .�: r�, . y.;.. m 3` : W6-P4-G2-RS2:. -P4-G2-RS '.- AWA -P 1-G-125 ; �zWA-P I-G.I-RSs2�' r; WA -P2 -G I -RS' - WA -P2 -G 1-RSa:; 4=W8 -P4 -G2 -RS< . 23 : „„a.. :-Nl .. E _.. .. _ .. .. - - - ;WA -P I -G I-125 :;_ <WA -P I -G I-1251;;; , WA -P2 -G 1125; ,AWA P2 G I RSr, . ;.; WB P4 G2 R CONNECTION OPTIONS OPTION 51LL TO FPM P05T TO 511-1- SAVE TO P05T RAFTER TO EAVE RIDGE CLIP TO RAFTER CLIP TO RIDGE WB CORNER COLUMN LITE "H" UTILITY "H" LITE "H741255 I (2) 3/8” DIA. AT EACH POST 3//8" (8)#8 CORNER P05T (8)##8 CORNER P05T (4) #10 CLIP TO EAVE 5CB5 GI DIA. AT 16"f O.G. (6)#8 LITE POST (6)#8 LITE P05T (I) #10 RAFTER TO EAVE (4) I/4" (2) 3/8" ® MAX. (6)48 UTILITY P05T (6)48 UTILITY POST (8) #10 CLIP TO RAFTER R2 7TB WITH 5TEEL TUBE IN5ERT (2) 3/8" DIA. AT (8)# 10 GORNER P05T (B(6I O CORNER POST (4) # 10 CLIP TO EAVE � 121 -W -41R513 G2 EACH P05T e 3/8" (6)#10 LITE POST (6k#10 LITE POST (1) #10 RAFTER TO EAVE (6) I/4" (2) 3/8" DIA. AT 16" O.G. (6)#10 UTILITY POST (6)#10 UTILITY P05T (8) #10 CLIP TO RAFTER C�s Q MAX. (2) 3/8" 41258 TO 511-1- (4) 1/4" 4R58 TO RAFTER WALL FRAMING OPTIONS O7 PE51GNATION PI OPTION II 23 41 5 16 WA CORNER COLUMN LITE "H" UTILITY "H" LITE "H" I UTILITY "H77BP ADJU5TABLE EAVE WB CORNER COLUMN LITE "H" UTILITY "H" LITE "H741255 I UTILITY' ADJU5TA8LE EAVE I Notes: I. The ultimate (Vult) wind loading are a5 per 2012 IBC, 2015 IBC/IRC and 201 6 CBC. 2. The V35 wind loading are a5 per 2006/2009 International Budding Code * 2006/2009 International Residential Code � 2012 IRC. 3. Shaded areas represents that steel ridge beam and post (to be designed by others) 15 required. 4. This summary pertaln5 to the structural Integrity of our unit up to, but not including, the connections to the existing structure and/or any new c01115tructlon. All substructure de5lgn requirements, and connectlon5 to the ex15ting structure are not Included In the Scope of work for the four seasons product and must be de5lgned by a local de5lgn profe55ional. 5. The values Indicated on the chart are for uniform loads and do not Include Special load condltion5 created by attachment to the ex15ting structure. These may Include snow drifting or unbalanced snow loading. Any 5peclal loading condltlon5 must be evaluated by a local de5lgn profe551onal. City of Wheat Ridge voi REP ��•Jt�S�sF:tiFR �GYIkFu�°�% ' O7 ROOF RAFTER SELECTION PI 51-63 P2 5HB3 P3 5LB5 P4 5CB5 P5 5G65-5061 P6 5G65-412513 ® RIDGE BEAM 5ELEGTION RI 7TB R2 7TB WITH 5TEEL TUBE IN5ERT R3 12LW R4 � 121 -W -41R513 R5 STEEL BY OTHERS City of Wheat Ridge voi REP ��•Jt�S�sF:tiFR �GYIkFu�°�% ' 15814 _ in in xC4 �UD��0 F o a �P4wz Z ow ino Z A Un Z ,:4 o0 In Pq 0P4<x WO w as z � � 00 0 LO x U] w P 0 W O � o Q /\ 2-16-14 RD 1 12-31-15 RD REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-18 18 OF 19 Q � z z z � � 111 C�s Q Cn kn ll1 CS 11J 111 = v R. No.DATE BY /\ 2-16-14 RD 1 12-31-15 RD REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-18 18 OF 19 FOUR SEASONS 5UN200M5 230 SUN E 5TA125 CATHEDRAL DESIGN 1 z Vas 120 MPH WIND LOAD EXP. G (2000) (2000 IRG/IDG x.2012 IRG Vulf 150 MPH WIND LOAD EXP. G (2012) I15C, (2015) IDG/IRC � 2016 CDC LOAD: 20 P5F / V3s 120 MPH WIND LOAD EXP. G (2006) (2009) IRG/IBG e 2012 IRG ROOF PITCH : 4 ON 12 LOAD: 60 P5F / V35 120 MPH WIND LOAD EXP LOAD: 20 P5F / Vult 150 MPH WIND LOAD EXP. G (2012) 15G (2015) IBG/IRG e (2016) GBC LOAD: 60 P5F / Vult 150 MPH WIND LOAD EXP LOAD: 40 P5F / V3s 120 MPH WIND LOAD EXP. G (2006) (2009) IRC/IBC, e 2012 IRC LOAD: 40 P5F / Vult 150 MPH WIND LOAD EXP. G (2012) IBC, (2015) IBC/IRG e (2016) GBG OPTION WALL e ROOF FRAMING CONFIGURATION P05T TO SILL EAVE TO P05T RAFTER TO EAVE FRONT WALL LENGTH, FT. FRONT WALL LENGTH, FT. FRONT WALL LENGTH, FT. FT. II' PROJEGTION, FT. II' 13' 15' 17' 19' 21' 23' II WB -PI -C2 -RI WB -PI -C2 -RI WB -PI -G2 -RI WB -PI -G2 -RI WB -PI -G2 -RI WB -P2 -G2 -RI WB -P2 -G2 -RI 12 WB -PI -C2 -12I WB -PI -G2 -12I WB -PI -G2 -RI WB -PI -G2 -RI WB -PI -G2 -RI WB -P2 -C2 -RI WB -P2 -G2 -12I 13 WB -PI -G2 -12I WB -PI -G2 -RI WB -PI -G2-21 WB -PI -G2 -RI WB -PI -G2 -2I WB -P2 -G2 -R2 WB -P2 -C2 -R2 15 WB -PI -G2 -RI WB -PI -G2 -R2 WB -PI -G2-22 WB -PI -G2 -R2 WB -PI -G2 -R2 WB -P2 -G2 -R3 WB--P2-G2-R3 16 WB -PI -G2 -R2 WB -PI -G2 -R2 W13 -PI -G2 -R2 WB -PI -G2 -R3 WB -PI -G2-123 WB -P2 -G2 -R3 W8 -P2 -G2 -R3 19 WB -PI -G2-23 WB -PI -C2-123 WB -PI -C2 -R3 WB -PI -G2 -R3 WB -PI -G2-23 WB -P2 -G2 -R3 WB -P2 -G2 -R3 21 WB -PI -G2 -R3 WB -PI -G2 -R3 WB -PI -G2 -R3 WB -PI -G2 -R3 WB -PI -G2-24 WB -P2 -G2 -R4 W13 -P2 -G2 -R4 22 WB -PI -G2 -R3 WB -PI -G2 -R3 W13 -PI -G2 -R3 WB -PI -G2-24 W0 -PI -G2 -R4 W13 -P2 -G2 -R4 WB -P2 -G2 -R4 23 WB -PI -G2-123 WB -PI -G2-123 WB -PI -G2-124 I WB -PI -G2-124 WB -PI -C2 -R4 WB -P2 -G2-124 =<WB -P2 -G2 LOAD: 40 P5F / V3s 120 MPH WIND LOAD EXP. G (2006) (2009) IRC/IBC, e 2012 IRC LOAD: 40 P5F / Vult 150 MPH WIND LOAD EXP. G (2012) IBC, (2015) IBC/IRG e (2016) GBG G (2006) (2009) IRC,/15G e 2012 IRG G (2012) ISG, (2015) IDG/RG e (2016) OPTION WALL e ROOF FRAMING CONFIGURATION P05T TO SILL EAVE TO P05T RAFTER TO EAVE FRONT WALL LENGTH, FT. FRONT WALL LENGTH, FT. FRONT WALL LENGTH, FT. II' 13' PROJECTION, FT. II' 13' 15' 17' 19' 21' 23' II WB -PI -G2 -RI WB -PI -G2 -RI WB -PI -G2 -RI WB -PI -G2 -RI WB -P2 -G2 -RI WB -P2 -G2 -RI WB -P3 -G2 -RI 12 WB -PI -G2 -12I WB -PI -G2 -RI WB -PI -G2 -RI WB -PI -G2 -RI WB -P2 -G2 -RI W8 -P2 -G2-122 W8 -P3 -G2 -R2 13 WB -PI -G2 -RI WB -PI -G2 -RI WB -PI -G2 -12I WB -PI -C2-22 W5 -P2 -G2 -R2 WB -P2 -G2 -R2 W8 -P3 -G2 -R2 15 WB -PI -G2-122 WB -PI -G2 -R2 WB -PI -C2-122 WB -PI -G2 -R3 WB -P2 -G2 -R2 W8 -P2 -G2-122 W13 -P3 -G2-123 16 WB -PI -G2 -R2 WB -PI -G2 -R3 WB -PI -G2-123 WB -PI -G2 -R3 WB -P2 -G2 -R3 WB -P2 -G2-123 WB -P3 -G2 -R3 19 - - - WB P I G2 123 - - - WB P I G2 123 - - WD -P I G2-123 - - WD -P I G2-123 - - WB -P2 G2 123 M - P2 -G2 -R4 WB P 124 WB -P3 -G2 -R4 21 WB -PI -G2-123 WB -PI -G2 -R3 WB -PI -C2-124 WB -PI -G2 -R4 WB -P2 -G2 -R4 WB -P2 -G2-124 `FWB-P3 G2 -RS 22 WB -PI -G2-123 WB -PI -G2-124 W13 -PI -G2-24 WB -PI -G2-124 WB-P2-G2-R4:AWB-P2-G2-RSv.: 23 WB -PI -G2 -R4 WB -PI -G2 -R4 WB -PI -G2 -R4 - W6 -P1 -G2 R5 �J_ Ivp_-P2-G2-R5z ^i WB -P2 -G2-125 AWB -P3 -G2-125 G (2006) (2009) IRC,/15G e 2012 IRG G (2012) ISG, (2015) IDG/RG e (2016) LOAD: 80 P5F / V3s 120 MPH WIND LOAD EXP. G (2006) (2009) IRG/IBG e 2012 IRG LOAD: 80 P5F / Vult 150 MPH WIND LOAD EXP. G (2012) IBC, (2015) IBC/112G e (2016) GBG OPTION WALL e ROOF FRAMING CONFIGURATION P05T TO SILL EAVE TO P05T RAFTER TO EAVE FRONT WALL LENGTH, FT. FRONT WALL LENGTH, FT. PROJECTION, FT. PROJECTION, FT. II' 13' 15' 17' 19' 21' 23' II WB -PI -G2 -RI WB -PI -G2 -RI WB -PI -G2 -R] WB -P2 -G2 -RI WB -P2 -G2 -R2 We -P4 -G2 -R3 M -P4 -G2 -R3 12 WB -PI -G2 -RI M -PI -G2 -RI WB -PI -G2-122 WB -P2 -G2-122 WB -P2 -G2 -R3 WB -P4 -G2-123 W5 -P4 -G2 -R3 13 WB -PI -G2 -R2 WB -PI -G2 -R2 WB -PI -G2 -R2 WB -P2 -G2 -R3 WB -P2 -G2 -R3 WB -P4 -G2 -R3 WB -P4 -G2 -R3 15 WB -PI -G2-123 WB -PI -G2 -R3 WB -PI -G2 -R3 W8 -P2 -G2 -R3 WB -P2 -G2 -R3 WB -P4 -G2 -R3 W5 -P4 -G2 -R4 16 WB -PI -G2-123 WB -PI -G2-123 WB -PI -G2 -R3 WB -P2 -G2-123 WB -P2 -G2 -R3 WB -P4 -G2-124 I W13 -P4 -G2-124 19 WB -PI -G2-123 WB -PI -G2-123 WB -PI -C2-124 WB -p2 -G2-124 WB -P2 -G2-124 WB P4-G2-RE,tR, B-P4-G2-R5.�. 21 WB -PI -G2 -R4 WB -PI -G2-124 WB -PI -G2-124 t:WB-P2-G2-125 W6 -P2 -G2-125. `'WB -P4 -G2-125` ;Ag;WB-P4-G2-R5.'': 22 3 W13 -PI -G2-124 WB -PI -G2 -R4 Wb -PI -G2424 «WB -PI -G2-125-:' »3NB-P I -G2-125 :=k WB -P2 -G2-125 "` WB -P2 -G2 -R5 �ffi' W15 -P4 -G2-125 .r'"°WB-P4-G2-RS 5 *WB-PI-G2-R5'r. WB-P2-G2-12?r WB -P4 -G2-125+ `WB -P4 -G2-125-' LOAD: 80 P5F / V3s 120 MPH WIND LOAD EXP. G (2006) (2009) IRG/IBG e 2012 IRG LOAD: 80 P5F / Vult 150 MPH WIND LOAD EXP. G (2012) IBC, (2015) IBC/112G e (2016) GBG CONNECTION OPTIONS OPTION WALL e ROOF FRAMING CONFIGURATION P05T TO SILL EAVE TO P05T RAFTER TO EAVE FRONT WALL LENGTH, FT. CLIP TO RIDGE PROJECTION, FT. II' 13' 15' 17' 19' 21' 23' II WB -PI -G2 -RI W5 -PI -G2 -RI WB -P2 -G2 -R2 WB -P2 -C2 -R3 WB -P4 -G2 -R3 WB -P4 -G2 -R3 W5 -P4 -G2 -R3 12 WB -PI -G2 -R2 WB -PI -G2-122 WB -P2 -G2 -R3 WB -P2 -G2 -R3 WB -P4 -G2 -R3 WB -P4 -G2 -R3 WB -P4 -G2 -R3 13 WB -PI -G2-22 WB -PI -G2-123 WB -P2 -G2 -R3 WB -P2 -G2-123 WB -P4 -G2 -R3 WB -P4 -G2-123 WB -P4 -G2 -R4 15 WB -PI -G2-123 WB -PI -G2-123 WB -P2 -G2 -R3 WB -P2 -C2 -R3 WB -P4 -G2 -R4 WB -P4 -G2 -R4 "�'kn-P4-G2-25';0, 16 WB -PI -G2 -R3 WB -PI -G2 -R3 WB -P2 -G2 -R3 I W8 -P2 -G2 -R4 WB -P4 -G2 -R4 WB P4 -G2-125; *zWB-P4-G2-125 19 WB -PI -G2 -R4 WB -PI -G2-124 4 WB -P2 -G2_ 15::;: AWB -P2 -G2-125 ,;,.VJB-P4-G2-125_; •" kWB P4 -G2 -RSA:; µ:W6 -P4 -G2 -R5' -c. 21 WB PI -G2-124 _� v,:WB-PI-G2-RSz=< _,��WB-P2-G2-125'; ::-yWB-P2-G2-RS • 'r= WB -P4 -G2-125;2 _aysWB P4 -G2-125`.," :`x WB -P4 -G2-125*: 22 AWB p1-G2-R5r:;?WB-PI-G2-R5'rrT,WB-P2-G2-125?`WB-P2-G2-125% „3W6 -P4 -G2-125 AWB -P4 -G2-{25 ;„f WB -P4 -G2-125 23 AWB -PI -G2-125> WB -PI -G2 -RS' . r WB -P2 -G2-125 y. ?`.•;WB -P2 -G2-125; ', F WB -P4 -G2-125` ;' .:.WB -P4 -G2-125 ti�=1 W13-P4-G2-RSs CONNECTION OPTIONS OPTION SILL TO FDN P05T TO SILL EAVE TO P05T RAFTER TO EAVE RIDGE CLIP TO RAFTER CLIP TO RIDGE 5H63 (2) 3/8” DIA. AT (B)#g CORNER P05T (8)#8 CORNER P05T (4) #10 CLIP TO EAVE 5GB5 GI EACH P05T f 3/8" (6k#8 LITE POST (6)#8 LITE POST (I) #10 RAFTER TO EAVE (4) I/4" (2) 3/8" ® DIA. AT 16" O.G. (6)#8 UTILITY P05T (6)#8 UTILITY P05T (8) #10 CLIP TO RAFTER 122 7TB WITH STEEL TUBE INSERT MAX. 12LW 24 12LW-41255 R5 (2) 3/8" DIA. AT (8)#10 CORNER P05T (8)#10 CORNER P05t(6)#10 (4) #10 CLIP TO EAVE G2 EACH P05T £ 3/8" (6)#10 LITE P05T LITE P05T (I) 410 RAFTER TO EAVE (6) I/4" (2) 3/8" DIA. AT 16" O.G. (6}#10 UTILITY POST (6)##10 UTILITY P05T (B) #10 CLIP TO RAFTER MAX. (2) 3/8" 4255 TO 511-1- (4) 1/4" 41R58 TO RAFTER WALL FRAMING OPTIONS OPTION DESIGNATION I 2 3 4 5 6 WA CORNER COLUMN LITE "H" UTILITY "H" LITE "H" UTILITY "H7713P I ADJU5TABLE EAVE WB CORNER COLUMN LITE "H" UTILITY "H" I LITE "H"/4R5B I UTILITY "H"/7BP I ADJU5TABLE EAVE Notes: I. The ultimate (Vult) wind loading are a5 pef_ 2012 IBC, 2015 IBC/IRC and 2016 CBC. 2. The V35 wind loadmej are a5 per 2006/2009 International Building Code * 2006/2009 International Residential Code * 201 2 IRC. 3. Shaded areas represents that steel ridge beam and post (to be de51gned by others) 15 required. 4. ThI5 summary pertaln5 to the structural integrity of our unit up to, but not including, the connectlon5 to the exl5ting structure and/or any new con5tructlon. All 51Jb5tructurc de51gn requlrement5, and connectlon5 to the CX15tmg structure are not included In the Scope of work for the four seasons product and must be de5l6jned by a local de51gn pr0fe55lonal. 5. The values indicated on the chart are for uniform loads and do not Include 5peclal load condltlon5 created by attachment to the exl5t1ng.5tructure. These may include snow drifting or unbalanced snow loading. Any 5peclal loading condltlon5 must be evaluated by a local de516jn profe55lonal. city of Wheat Ridge r a3 _ r lilr,F�u;�rk11i1;;�1�x�A rn U) x U) U x ::4 �D0 O a wz C) Z w o W o Z Q U) z PEI 124 0 HP4 P4IY. W W W Z O U a00G, (Y, o W O �D L Q CY Cl - Q 0 ~ z z z � 111 O fl Q1 C'4 IS) CY Ll� 11! Q REV. No.I DATE I BY 1A2-16-14 2-16-14 RD 1 12-31-15 RD 2 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-19 19 OF 19 O7 ROOF RAFTER 5ELEGTION PI 5L53 P2 5H63 P3 51-55 P4 5GB5 P5 5C55 -5G51 P6 5G55-4855 ® RIDGE SEAM SELECTION RI 7TB 122 7TB WITH STEEL TUBE INSERT R3 12LW 24 12LW-41255 R5 STEEL 5Y OTHERS city of Wheat Ridge r a3 _ r lilr,F�u;�rk11i1;;�1�x�A rn U) x U) U x ::4 �D0 O a wz C) Z w o W o Z Q U) z PEI 124 0 HP4 P4IY. W W W Z O U a00G, (Y, o W O �D L Q CY Cl - Q 0 ~ z z z � 111 O fl Q1 C'4 IS) CY Ll� 11! Q REV. No.I DATE I BY 1A2-16-14 2-16-14 RD 1 12-31-15 RD 2 REVIEWED BY: AS DWG. BY: RD DATE: 1-10-11 JOB#: STARCATH-19 19 OF 19 PEa,�IIT:�.'� `, ADDRESS:/(,� JOE BODE:Al INSPECTION RECORD�� Z Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert, {�+ 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. {�+ 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground r% 41.a /%�_.—._ I1._J _______ 1 -VL VGvC1 Uiluergrouna or 6eiow i in-siab work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comme s 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing {�+ 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS -�q r7n, 1,",n--� Rough Inspection (continued) Date Inspector CommentsInitials 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector CommentsInitials 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof '1 `.Jj— ' / 1 410 Final Window/Door 411 Landscape/Park/Planning Inspections from these entities shall be requested one week in advance. For landscaping and parking inspections please call 303-235-2846 For ROW and drainage inspections please call 303-235-2861 For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works 413 Flood plain Inspection 414 Fire Insp. / Fire Protection 415 Public Works Final 416 Storm Water Mgmt. 417 Zoning Final Inspection 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. Property Address Permit Number Permit Issued Date The City of Wheat Ridge Third Party Form Check List 7� u� ka s 20r 7 a 7 7 Owner Information Property Owner Information Property Owner Address Inspector Information Inspection Company Inspector Name Inspector Contact info 6;17zei, P1 Ila V Inspector Statement and Acknowledgement I hearby acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * I hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Polies -ani Rrocedure and Manufacturer's recommendations and specifications. 7 ..- . i ..�� tea► ., . „6 Property Owner Statement of Acknowledgement *1 hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat Rid g ��rilding Division inspection. Propery Owner/Agent: Date: This original document and permit card, as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W. 29th Ave Wheat Ridge CO 80033 Draft Date: 7/26/17 Please add note to reverse side The City of Wheat Ridge Inspection Check List notes Mid -Roof q � 70 ( ')tzf,,1 sr Roof Inspection ❑ N/A ❑ Pass ❑ Fail ❑ N/A ass ❑ Fail Structural roof components ❑ N/A A --Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A / Pass ❑ Fail Flashing for roof and walls ❑ Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Vk/A ❑ P25S ❑ Fail Verify sheathing nail pattern (See Policy & Procedures) ❑ N/A Pass ❑ Fail Crickets and saddles where needed ❑ N/A Pass ❑ Fail Verify B vent must have boot same ❑ N/A Pass ❑ Fail gauge as pipe Verify vent caps ❑ N/A Pass ❑ Fail Verify no flashings are damaged ged or rusted [J_f-N/A ❑ Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle �/A ❑ Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A [ Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A ( Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A Pass ❑ Fail Dripedge should extend down min 2" ❑ NIA Pass ❑ Fail past roof deck Dripedge shall be mechanicaly fastened 12" OC N/A ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope N/A ❑ Pass ❑ Fail Above roof insulation R-25 N/A ❑ Pass ❑ Fal Below roof residential R-33 N/A ❑ Pass ❑ Fail Below roof commercial R-32 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final inspection Metal Roof Shiraai�s Rea�e6r�elrnengs N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Reguirements N/A ❑ Pass ❑ Fail Clay and concrete the shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Mid -Roof Notes c 11 Company Name: f� L- L Lf— Inspector signature: j - Date of Inspection: JL' —1 _5 - % The City of Wheat Ridge inspection Check List notes Final Roof Roof Inspection ❑ N/A ❑ Pass ❑ Fail ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A El Pass ❑ Fair Flashing for roof and wafts ❑ Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) II N/A ❑ Pass ❑ Fail Verify sheathing nail pattern (See Policy & Procedures) 0 N/A Pass ❑ Fail Crickets and saddles where needed ❑ N/A Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A fa Pass ❑ Fair Verify vent caps ❑ N/A Pass ❑ Fair Verify no flashings are damaged or rusted ❑ N/A 51 -Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle {.N/A ❑ Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A Pass ❑ Fair Ice and water shield 2` in heated wall spaces El N/A (�� 1] y� Pass ❑ Fail Underlayments must follow 2012 IRC 12012 iBC ❑ N/A �P ass ❑ Fail Verify roof slope for proper drainage ❑ N/A 93Pass ❑ Fair Dripedge shall have min of 2" overlap ❑ N/A -Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A `Pass ❑ Fair Dripedge shall be mechanicaly fastened 12" OC Q,N/A ❑ Pass ❑ Fair 30 LB roll roofing shall not be applied to roof slopes less than 2:12 slope; Exception: detached garages, patios, carports, open on three sides with min. slope of 1:12 p N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope L) N/A ❑ Pass ❑ Faii Above roof insulation R-25 N/A ❑ Pass ❑ Fail Below roof residential R-38 N/A ❑ Pass ❑ Fait Below roof commercial R-32 N/A ❑ Pass ❑ Fair Modified Bitumen, EPDM, TPO min slope 114:12 slope must be installed in accordance with the manufacturer's specifications - Must have manufacturer's leiter of warranty with the address on the letter for final inspection Metal Roof Shingles Eieguirements N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less N/A ❑ Pass ❑ Fail 3:12 Metal valley flashing shall be the same material as roof N/A ❑ Pass ❑ Fair Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile goofs Reguirements ❑ N/A ❑ Pass ❑ Fair Clay and concrete file shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Final Roof Notes u � �, Company Name:� Inspector signature: / ,, Date of Inspection: — !/J- -A S City of Wheat Ridge � r Residential Roofing PERMIT - 201707877 PERMIT NO: 201707877 ISSUED: 09/29/2017 JOB ADDRESS: 2970 Upham ST EXPIRES: 09/29/2018 JOB DESCRIPTION: Residential Re -roof to install Malarkey asphalt shingles - 32 sq Pitch - 4/12 *** CONTACTS *** OWNER (720)291-3753 GRANTHAM DANIEL T SUB (720)464-7498 Michael Lindberg 170483 Woodberg Roofing & Restoration *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,224.00 FEES Total Valuation 0.00 Use Tax 172.70 Permit Fee 188.45 ** TOTAL ** 361.15 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. ► ' , City of Wheat Ridge � r Residential Roofing PERMIT - 201707877 PERMIT NO: 201707877 ISSUED: 09/29/2017 JOB ADDRESS: 2970 Upham ST EXPIRES: 09/29/2018 JOB DESCRIPTION: Residential Re -roof to install Malarkey asphalt shingles - 32 sq 4/12 Pitch - I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the leg wrier of the and and am authorized to obtain this permit and perform the work described and approved in conjunction with this a t. f her attes that Im legally authorized to include all entities named within this document as parties to the work to be per ed tat all k to pAormed ' isclosed in this docuent nd/or its' accompanying approved plans and specifications. 70 WI -7 Signature of OWNER or -CONTRACTOR (Circle one) Date " 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po icies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Off-cial and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or aq rdinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett ��� 1707 f, 7 7 From: no-reply@ci.wheatridge.co.us Sent: To: Wednesday, September 27, 2017 3:47 PM CommDev Permits �- Subject: Online Form Submittal: Residential Roofing Permit Application- Follow Up Flag: Follow up Flag Status: Completed Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) 2970 Upham St Ernestine Grantham 720-291-3753 113 Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract egrantham8@gmail.com Yes Grantham contract.pdf CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Woodberg Roofing & Restoration 170483 720-464-7498 Contractor Address 1685 S. Colorado Blvd unit S-266 Denver Colorado, 80222 (Primary address of your business) Contractor Email Address ml@woodbergroofing.com Retype Contractor Email ml@woodbergroofing.com Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or 32 No -- No Pitched roof (2:12 pitch or greater) 114 both? (check all that apply) What is the specific pitch of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: Type of material for the PITCHED roof. If "Other" is selected above, describe here: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) 4 32 Malarkey Legacy shingles Other Malarkey Legacy shingles Re -roof of house SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. Yes Yes Yes 115 I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Mike Lindberg Email not displaying correctly? View it in your browser. 116 1685 S. Colorado Blvd Unit S-266 Denver, CO 80222 lWdodber 720 464-7498 woodbergroofing.com ACCREDITED info@woodbergroofng.com BUSINESS ROOFING & RESTORATION BB Customer bartieJ/hc�stii.e �.r�nfln� Phone 7a0 ' d9/- 3753 Email Address d270 0 LJ,4 City1Jl erx.f/ 4 e State 4:a zip S � AGREEMENT Woodberg Roofing & Restoration, LLC (hereinafter "WRR") agrees to provide the labor and materials for,%e� insurance ; Claim # Qd -04, ' E2Y with the approximate "commencement" of work the week of '—Z -lc9 / 7 (per terms). The customer gives WRR permission to speak and negotiate with their insurance company to establish a total Replacement Cost Value (RCV) for repairs. The customer has the right to rescind this contract within 72 hours of entering into it and can notify WRR of rescind via email, mail, or in person. SPECIFICATIONS OF MATERIALS AND WORK PERFORMED _Roofing _Tear -off, haul & dispose of existing roofing material _Install pipe jacks _Install roof vents _Install In the Color _Install felt paper or synthetic _Install ice & water shield if required by city code and in accordance with claim _Install drip edge if required by city code and in accordance with claim _Clean up property _Lifetime workmanship warranty **Customer is responsible for all HOA approvals on materials and colors *" Customer is responsible for coordinating and scheduling satellite dish remounting realignment and calibration with their service provider _Additional Work, Details & Specifications f_ lei. •` r r /v - ♦ v " • TERMS The total cost will be equal to the full and final Replacement Cost Value (RCV) as determined between the insurance company and WRR. Customer understands that if s/he has RCV coverage for these repairs, s/he will be out of pocket the deductible amount and if s/he has Actual Cash Value (ACV) coverage, s/he will be out of pocket the difference between the ACV and RCV. Changes (supplements, overhead/profit (O&P), permits) from the current RCV to the final RCV will be reflected in the insurance company's estimates and loss reports and are considered updates to this agreement. The customer agrees to pay WRR in whole for these additions. The current RCV estimate for the specified work and materials for known damages is G ,3-31173, and progress payments will be paid to WRR as received from the insurance company. WRR shall hold in trust any payment from the customer until the delivery of materials at the site or has performed a majority of the roofing work on the property. Make all checks payable to Woodberg Roofing & Restoration. Half down of RCV upon DELIVERY of materials $ Date Initials Remainder of ACV payout upon completion Date Initials Remainder of RCV, O&P, supplements, permit fees $ Date Initials FINAL TOTAL/RCV $ Date Initials Customer and WRR agree to the specifications, materials and terms stated herein, on back and supplements to this aqreement. Customer Signature Date W RR, by&.zcQ d t representative Signature Date to `15--dlol7 City of Wheat Ridge Residential Roofing PERMIT - 201704677 PERMIT NO: 201704677 ISSUED: 07/24/2017 JOB ADDRESS: 2670 Upham ST EXPIRES: 07/24/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration asphalt shingles with ROOF DECKING 28 sq. *** CONTACTS *** OWNER (303)763-9114 LAWRENCE D THOMPSON FAMILY TRU SUB (303)763-9114 Scott Riopelle 019938 Interstate Roofing Incorporate *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,383.50 FEES Total Valuation 0.00 Use Tax 197.05 Permit Fee 204.30 ** TOTAL ** 401.35 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201704677 PERMIT NO: 201704677 ISSUED: 07/24/2017 JOB ADDRESS: 2670 Upham ST EXPIRES: 07/24/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration asphalt shingles with ROOF DECKING 28 sq. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be p rfo d is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRAtIOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of anmanner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holdy er shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable co y ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz X0004&77 From: no-reply@ci.wheatridge.co.us Sent: Friday, July 14, 2017 12:12 PM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Danny Residential Roofing Permit Application f This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR Z PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number 2670 Upham St Gloria Thompson 3037639114 Property Owner Email jwiles@interstateroof.com Address 3� Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Interstate Roofing 019938 3037639114 Contractor Email Address jwiles@interstateroof.com Retype Contractor Email jwiles@interstateroof.com Address DESCRIPTION OF WORK Are you re -decking the Yes roof? Description of Roofing O/C Duration Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 28 material selected above? Does any portion of the No V property include a flat roof? If yes, how many squares Field not completed. on the flat roof? TOTAL SQUARES of all 28 V roofing material for this project Provide additional detail house, 5:12 pitch here on the description of z work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contractT value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant John Quante Email not displaying correctly? View it in your browser. 3 hv�lshttJTmmmfln't reterrallst COiii NTERSTATE -f',- - ROOFING Submitted To �!1 /D IAS (�nym Email '1. Phone �� X38-2gJ Alt. Street a � 70 diol-vimy + City &)&4r1,rAt tate Insurance Company claim# Poficy# ACCREDITED BUSINESS 9 Phone zip Scope of Work and Materials to be Provided. The scope of work and materials identified below are the scope of work recommended by Interstate Roofing Inc.; however, interstate Roofing is not obligated to perform any part of the scope of work that is not approved by the insurance company unless you authorize the work and agree to pay for this additional work. Manufacturer Tear off layers of composition shingles ❑ Tear off one layer of wood shingles Install Decking (7/16" OSBM53> install new felt install pre -painted save metal to code - Color Brown Charcoal Tar. While int. Valley(s) will be closed ❑ Valleys will be open Ridge(s) to be color -coordinated Ridge(s) will be 'High Profile Ridge" color -coordinated shingles Install new pipejacks Replace Vents as needed kRe-flash chimneys and all wall abutment as needed and if possible (stucco or siding may be a deterrent) ❑ Install In. ft. of series ridge vent ❑ InstallIn. ft. of ice & water shield to code Install � nails per shingle Clean out gutters 5 year workmanship warranty Interstate Roofing, Inc. will provide general liability insurance coverage of $2,000,000, general aggregate Make a magnetic sweep of driveway and yard for removal of any nails Remove all debris resu�agfrpm�ove work ❑ Special InstructionsLt.7j- I G. Li:�C•e Gv The approximate costs of the services based on damages known at the time this contract is entered is V J Interstate Roofing, Inc., however, will perform the scope of work approved by the insurance company for the arrunt of the insurance Approved proceeds, with no additional costs to you except for your deductible. The final scope and price agreed on between the insurance company and UP Interstate Roofing, Inc. shall become the final contract price for the insurance approved scope. You will be responsible to pay for any upgrades or additional work authorized by you that the insurance company determines is not covered within the scope of coverage provided by your insurance policy. Supplemental claims billed by Interstate Roofing, Inc. that are approved by the insurance company for additional work or increases in costs become a part of this contract. Approximate Dates of Service: These dates of service are subject to change due to unusual delays in transportation of materials, ordinary weather delays, or by any other causes beyond the reasonable control of Contractor Notice: If the property owner plans to use the proceeds of a property and causuaity insurance policy issued pursuant to part 1 of article 4 of title 10, C.R.S., to pay for the roofing work, pursuant to section 6-22-105, the roofing contractor cannot pay, waive, rebate, or promise to pay, waive, or rebate all or part of any insurance deductible applicable to the insurance claim for payment for work on the covered residential property. Terms: I (We) hereby authorize & instruct the insurance company & all lien holders to Include the name of Interstate Roofing, Inc. as co -payee on any subsequent loss drafts or checks after today's date as Indicated above. I (We) also authorize any legal representative and/or agent of Interstate Roofing, Inc. to obtain information necessary to complete any funding process relative to the claim number referenced above. I (we) further authorize Interstate Roofing, Inc. to pick up in person any loss drafts or checks on my/our behalf and behalf of Interstate Roofing. Deposit Amount:$ Interstate Roofing shall hold In trust any pi materials at the residential property site or preformed a majority of the roofing work on the property. I (We) agree, by signing below, to all the contract conditions, both front & back of this agreement Date Acceptance �` � Client SignatureIG& of Representative Corporate Headquarters Colorado SprIngs ofNoe Fort Collins office Cheyenne Office Black ins. Agency 1000 W. 47th Ave. 2161 N. Academy Blvd. P. 970.482.7722 F. 970.682.1018 1010 S Greeley Highway 9600 E Arapahoe Rd #205 Denver, CO 80211 Colorado Springs, Co 80909 Tori Free 877.898.8144 Cheyenne, WY 80211 Englewood, Cc 80112.3726 P. 303.783.8114 F. 303.789.3790 P. 719.471.9752 F. 719.597.4444 www.interstateroof,com P. 307.634.2553 (303) 397-7820 www.interstateroof.com info@ interstateroof.com Ay of C W h6at N f� dge com j try 1.11"YE LC OMEN'T M*0*406W 2-170 f§%W690** (please Phont �Wx, 0 FttC-4 I Iro' Plumbing: J r Soon 5� Mectmnical: b iiAc �s kt Squares _._— BTU's -- ,— Gallons 0 SIGNATURE OF U, AND AGREEMENT I hereby certify that thesetback distances proposed by this fwnnit application are accuratc and do not violate applicable otxfinancc�: , rules or regulatiom of the City c4' Wheat Ridge or covenanu, "ase meat s or ivitrictictns of rccord-, that all tneasurements sac urn and allegations snade aw accuratc. that I have read and agive to abide tai all conditions pritiml on this application and that I Ws'sunte full responsibility ftwr compliance with applicable City of'Whcat Ridge ccKf(,s and ordinances for work uraica- any perntit issixxt hale d cm this application, that I am the legal ownci or have b"m authorized by the IcT,, al owner of Ific prolwrty to perforin the des-crib d work and ain also authorizod Ity the legal owner ofany entity included on this applicaticaw to list that entity on this applicaiion. Irtfictra"Ve, (olvVER) WONYR,4CTOR) ,) qf (MVIVER) (CONT&WTOR) OGNAWIM 1.1-I'VK a M�� Plumbing Rough plumb for vanity sink, laundry sink, bar sink & toilet. Electrical The electrical and lighting layout is for count only. The electrician will decide the final layout using common sense and input from customers. Install arc fault protectors in bedrooms. Install GFIs in wet areas. Hallways shall have minimum width of 36 ". Carbon monoxide detector(s) required within 15 ft of all sleeping areas. _ Smoke Alarms shall be required in each sleeping room and outside each sleeping area per 2006 IRC, Section 313. Direct connect smoke alarms are required. Outlets in bedrooms shall be arc - fault protected. Outlet spacing shall comply with 2005 NEC. Minimum 50 CFM exhaust fan vented to exterior shall be provided in toilet rooms and bathrooms. Combustion air ducts within 12 inches of ceiling and floor, sized at the rate of I sq. inch per 2000 BTU's, are required Shutoff valves required on lavatories HVAC and water closets. 720 -333 -0911 BASEM A minimum of 21" of clear space is "o" °U1`E- e °°°° C O M P A N Y TheBasementCompany.Not Minimum 30" clear area for toilet is Interior Trim required with minimum 15" from _° d 1.1.WTC center to sidewall on each side. All miter cuts will have NEW 351°E°WPLI �E Handrails shall be provided on at Water hammer arrestors are prior to installation of � least one side of stairs at a height of casing, base and window Oe =w °P°«., ° ". _ _ _ _ _ ; . "ISSIE.L W' to 38" measured vertically from O n _1 the tread nosing. r w� In enclosed usable space beneath t � stairs, min. 1/2 -inch drywall is C =��M required on underside of stairs and i Framing on adjacent walls. Field verify measurements FAMILY 5, D I prior to constructing the walls. Walls in shower shall have non - CARPE absorbent finish to 6' above floor. ON�It� Plumbing Rough plumb for vanity sink, laundry sink, bar sink & toilet. Electrical The electrical and lighting layout is for count only. The electrician will decide the final layout using common sense and input from customers. Install arc fault protectors in bedrooms. Install GFIs in wet areas. Hallways shall have minimum width of 36 ". Carbon monoxide detector(s) required within 15 ft of all sleeping areas. _ Smoke Alarms shall be required in each sleeping room and outside each sleeping area per 2006 IRC, Section 313. Direct connect smoke alarms are required. Outlets in bedrooms shall be arc - fault protected. Outlet spacing shall comply with 2005 NEC. Minimum 50 CFM exhaust fan vented to exterior shall be provided in toilet rooms and bathrooms. Combustion air ducts within 12 inches of ceiling and floor, sized at the rate of I sq. inch per 2000 BTU's, are required Shutoff valves required on lavatories HVAC and water closets. Install 5 new heat runs Install 1 cold air returns A minimum of 21" of clear space is Install bath fan & vent to outside required in front of lavatories. Minimum 30" clear area for toilet is Interior Trim required with minimum 15" from center to sidewall on each side. All miter cuts will have biscuit joints glued Water hammer arrestors are prior to installation of required at quick - closing valves casing, base and window R2903.5 surrounds. Match existing trim and moulding. Install a sill and apron at art niches. Install crown moulding 1/2" from bottom of 6" top soffit on the double step soffit for ropelighting. Match existing door hardware. Paint grade doors and trim. d. B ASEMENT C O M P A N Y Mike Lichty 4756 Sluagete Or Highlands Ranch, CA 60130 Phone 720. 333 -0911 Fax: 720.344 -2869 www.thebasementcompany, net 114" Scale Drawing 22' - 1 " M b STAIRS CARPET 43 sq ft 720- 333 -0911 TheBasementCompany.Not In T� BASEMENT C O M P A N Y Wheat Ridge Building Department pproved BUIL FICIAL DATE Validity of permit: The issuance of a permit or approval of pans, specifications and computations shall not be a permit for, or an approval at, any violation to any of the provisions of the building cods or of any City ordinances. permits presuming to give authority to violate or cancel the provisions the Mudding codes or other ordinances c the City shall not be valid. APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Date: !3 Sign Plan checker Work shall comply with the following codes: 2006 IRC, 2006 IECC & 2005 NEC. FL 979 M , t,A'tJN DRY TILE r O n _1 r w� t � T� BASEMENT C O M P A N Y Wheat Ridge Building Department pproved BUIL FICIAL DATE Validity of permit: The issuance of a permit or approval of pans, specifications and computations shall not be a permit for, or an approval at, any violation to any of the provisions of the building cods or of any City ordinances. permits presuming to give authority to violate or cancel the provisions the Mudding codes or other ordinances c the City shall not be valid. APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Date: !3 Sign Plan checker Work shall comply with the following codes: 2006 IRC, 2006 IECC & 2005 NEC. FL 979 M , O n _1 w� C =��M i o I II / FAMILY 5, D I OPCI ` r CARPE ON�It� 216 sq ft o' ih d CC m s .i T� BASEMENT C O M P A N Y Wheat Ridge Building Department pproved BUIL FICIAL DATE Validity of permit: The issuance of a permit or approval of pans, specifications and computations shall not be a permit for, or an approval at, any violation to any of the provisions of the building cods or of any City ordinances. permits presuming to give authority to violate or cancel the provisions the Mudding codes or other ordinances c the City shall not be valid. APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Date: !3 Sign Plan checker Work shall comply with the following codes: 2006 IRC, 2006 IECC & 2005 NEC. FL 979 Al ► . r R r � - H >" z z w W C 1� M _1 w� C =��M Ca ON�It� Al ► . r R r � - H >" z z w W C 1� ~ tA A f\ a~ 1 W ~ O 5 W ~ w:3 0 Ap W n W = • O 7 ~ S N < N Q N fD 7 N a CD ~ 0 ~ ~ N 9 (D ~ 0 ~ ~ a L O ff a ~ a N L ~ k f. Q 0, 0 0 O ~ Z (D ~ ~ n o' v O N CD W~ m ~ • 0 r Z N v, O ~ O o ` z n • y (D v ~ M ~ Certificate of Completion AND/OR Compliance CITY OF WHEAT RIDGE 7500 W. 29TH AVENUE WHEAT RIDGE, COLORADO 80033 THIS CERTIFICATE VERIFIES THAT THE PROPERTY DESCRIBED BELOW, DOES COMPLY WITH THE WHEAT RIDGE BUILDING CODE, ZONING AND OTHER RELATED LAND USE AND DEVELOPMENT LAWS OF THE CITY OF WHEAT RIDGE FOR THE FOLLOWING PURPOSE. PERMIT # 15523 Single Family Addition OWNER: Grantham Residence ADDRESS: 2970 Upham Street PROPERTY ADDRESS: 2970 Upham Street. Wheat Ridge. CO 80033 CONTRACTOR: Kinsman Conshuction DATE 11/24/03 CHIEF BUILDING OFFICIAL ZONINGADMINISTRATOR 441' ~ ' INSPECTIONS WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE BUILDING SITE 24 HOURS NOTICE REQUIRED FOR INSPECTIONS WHEAT RIDGE, COLORADO 7500 WEST 29th AVENUE (303) 234-5933 INSPECTION RECORD I' JOB ADDRESS Z9 I 5~ a ~ TYPE OCCUPANCY BUILDING PERMIT N0. DATE ISSUED V'N OWNER C ran''t'Y&M BS;~G1bNCtJ CONTRACTOR jf1 YYALI, / (-dANYlAG&Y. SETBACKSFROM PROPERTYLINES: NORTH SOUTH EAST WEST INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB INSPECTION DATE INSPECTOR Foundations Footings Caissons Reinforcing or Monolithic Weatherproofing POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED Concrete Slab Floor Electrical (Ground Work) Plumbing (Ground Work) Heating (Ground Work) DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED Rough Electrical 2 , Rough Plumbing 1-11~ Air Test Gas Piping Rough Heating & Ventilation G~r Framing Insulation o/ Drywall Nailing Roafing Refrigeration Electrical Underground Final Electrical Plumbing Heating & Ventilation , / ~ ' Frame L G R.O.W. & Drainage Fire Department ~ Parking & Landscaping C ( L U 3 rGCX: - - B OCCUPANCY NOT PERMITTED UNTIL-G-RTIF1t ATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER v m ~ NCD w0 A 0 tom w~ W = ' O 7 N ~ N N Q' m m ' 3 m a m ~ d 0 ~ ID 3 N 'O (D ~ 0 ~ ; c- 0 oD a a ~ N N O n ~ CD 0 f-ii- ~ I~ r~ ilook C~~ (D 0 0 5- c N C ~ C ~ Z n _ 0 Cl) m ~m ~ r (D ~ y c gm z Vj '-I o'v m ~ 0 --I w 0 = N W ~ N co N ~ COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number Date 15523 5/14/2003 Property Owner: GRANTHAM RESIDENCE Property Address : 2970 UPHAM ST Contractor License No. : 21620 Company : Kinsman Construction Phone : Phone : 526-4063 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of W heat Ridge or covenants, easemenls or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, forwork under this permit. (OWNER)(CONTRACTOR) SIGN Construction Value : $81,000.00 Permit Fee : $1,119.05 Plan Review Fee : $727.38 Use Tax : $972.00 Total: $2,818.43 Use : Description : SINGLE FAMILY ADDITION BUILDING DEPARTMENT USE ONLY Zoning Comments: SIC Approval : MA 5/2103 Zoning : R-1 Building Comments:, Approval: BG PubliG'Works Comments: Sq. Ft. : 5113103. OK. USE S-1 PLANS FROM ORIGINALSUBMITTAL Approval: Walls Efeotrical License No : 20378 Company :Connelly Electric Co, Expiration Date : 2/28/2005 Approval: OK/KS ~ Roof : Stories Residential Units : Mechanical License No : 21621 Company : Custom Climates Expiration Date : 5/14/2004 Approval: ok/ks Plumbing License No :21534 Company :ARTHUR PLUMBING & MECH., INC Expiration Date : 2/12/2004 Approval : OKIKS (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Cobrado and to the Zoning Re9ulations and Building Cotle of W heat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days fmm issue date or (B) the building authorized is suspended or abandoned for a penod of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will ba made in the original Dlans and specifcations and any suspension or abandonment has not exceeded one (1) yeac If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the naWral flow of water causing a drainage probiem. (5) Contractor shall notify the Building Inspector lwenty-four (24) hours in advance for all inspections and shall receive writlen approval on inspeclion card before proceediing with successiva phases of the job. (6) The issuance of a permit or the approval of drawings and specifcations shall nol be conslrued to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other oNinance, law, rule or regulation. Chief Building Inspector . , . Junc 11.2003 nttn: Christy Citv of Wheatridge 303-235-2857 Dear Christy: This Icller scrves as natice that Connclly Glectric will be the elcctrical company working on our.job sitc localed at 2970 Upham Strcel. Should you nc<:d anything further, plcase don't Iiesitalc to contact us. Thank You Kinsman ConsCruction T•d EObE66EE0E uozzonj,4suo3 uewsutr eLS:TT 60 SS unC , COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 15523 BUILDING INSPECTION LINE -(303-234-5933) Date : 5/14/2003 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: GRANTHAM RESIDENCE Property Address : 2970 UPHAM ST Phone : Contractor License No. : 21620 Company : Kinsman Construction Phone : 526-4063 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $81,000.00 I hereby certify that the setback distances proposed by this permit application are accurale, and Permit Fee : $1,119.05 do not violate applicable ordinances, rules or regulations of lhe City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations Plan Review Fee : $7273$ made are accurate; that I have read and agree to abide by all con tions prinled on this Use Tax : $972.00 application, and that I assume full responsi " for co . li e th t Wheat Ridge Building Code (U.B.C.) and all other applicable Wh Ridg in s, ork under this p rmit. $18 43 DATF / - , . ~ (OWNER)(CONTRACTOR) SIGNED Use : efiy tO Description : SINGLE FAMIL ADDITION ~pt¢: ,o e ~ ~at\ngp o~cl~ i~tcsP"'""Ven~eP" cr,csU•,~~<'` BUILDING DEPARTMENT US~,~Q►t ~pyCN~d~eQo~~e pc',na3°~~:, Sib ~8 Zoning,Comments;. Approval : MA 512103 .~eC edw~ `~r,E(in~r Zoning : R-1 yNb~otSTesu Build1466mmgnfS:J 5I13103. OK. USE S-1 PLANS FROM ORIGINALSUBMITTAL Approval: BG . Public 1Norks Camlm4nts; Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : 20549 Company :Comfort Electric Expiration Date : 2/28/2005 Approval : OKIKS Plumbing License No :21534 Company :ARTHUR PLUMBING & MECH., INC Expiration Date : 2/12/2004 Approval : OKIKS Mechanical License No : 21621 Company : Custom Climates Expiration Date : 5/14/2004 Approval: ok/ks (1) This permit was issuad in accordance with the provisions set forth in yopur application antl is sublect to ihe laws of ihe State of Colorado and to the Zoning Regulations antl Building Code of Wheat Ridge, Colorado or any ofher applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixry (60) days from issue date or (B) ihe building authorizetl is suspended ar abandoned for a period of 120 days. (3) If ihis permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have heen or wili be made in the original plans and speci(ications and any suspension or abandonment has not exceeded one (1) yeac If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done lhat will change the natural Flow of water causing a tlrainage problem. (5) Contractor shall notify ihe Building Inspector iwenty-four (24) hours in advance for all insDeclions and shall receive written aOProval on inspection card before proceediing with successive phases of the job. (6) 7he issua o a permit or e approval oF drawings and specifications shall not be consirued to be a permit for, nor an approval o[ any violation of the prom ftq-of t es or any other ordinance, law, rule or regulation. 05/ .'i'/~-e....... Chief Building Ins ctor S: 39dd 1SN0D NdWSNIN:OI Wtl9S:BT 3n1 2002-62-adtl !'AMmNITVTWVN.T~DM1V~rnc_ o~ ~ ~ W„ , u.,, ~,m tlui'1~ YClllllt 1VUB1bEi: ~ ~l $1J1T.DIN6INSP8CTTpN I,A~iS - 303-234-5933 Dxu~ ` CIT'Y Ol+' W~A1' RIDGE _ 7500 WEST 29T~ AVF.IVU$ ~o oP WHEAT ltlbCF., CO 80215 -(?03-235-2855) APP~CAMi . Properry Address: LtekArl\ Phoae : ccl Con#actotLiaenseNo.; 09t'tlkltlCOMRACfDR STfdYwTUgg OFi7M1&A6Ta./AiYCr AND AG9Uhffirff ••.,'~.cap~apo~dbYffiapmnit~pplicstianareaawde. C011S{711Gt1072 VBIIiC:$ O OI Gbd,, o "aow w;a:caye,.abie~sdmmcas.r¢laar*eguktioosoftlntityofWheatRidgeor covsnmts,aasea~aeraozxastric'tiensofreecrd,9utaI:messurwlwnisshown~endsllegada~ QCIIri1tr+BE:S modo me accur.x; thac i h..o roaa ana assa m.biao br.u conaitlono m+nua on rtris Plau 12eview Fee:$ spplieatlen md ffiat I usfuueRill ncponaibility for camplianx witlt iLe WLest Ridgt BiO]d'ag Code {U.B.C} and An otL1 er 0" ic Wh7a4 Ridge Ord'amcec, im work tmder U50 TA7c:$ TW~°` Torat:a DESGXPTION: N}°j ^ '903 ~ S ~ BUII.DLNG AEP.SRT-W^!1' USE ONILX , SIC: Sq.Ft.: 20NIN0 COMNEN75: AppLroval: 'fi~^~ sI Z l °-7> I ~4)l~: \ I nEMIu.naecnMrasv==: S l 3~~ 3 d~( ! ffse SIf 0 .9 •r5 /%0 ,w ApprovaL ~ t'Yoo ~~9 ausuawowracoare xrs: I a,..._ A.$jaenual. iJn]ls. + Filactrical License No: Plumbi4g License :2/'5 ~ t~ Mechanieat Liceosa No! , c'°mpany: (~6m4R4' C/ccAi, L CouipatiY , UEM ~S°~°Y~ CuS~a M, c N~akeS r~{tt~,- r, Lxpaston nate: Expiratian~te: Fxpaatioa Aate: APProval: APProval: pppreral• (1) xaupftW3rn„tnroem.wmdmoew;mmepmw.iamssatfaaminrm ePCife*xmmais.n7aiwroakLwcotmes.netetimlo.uammezoning 'ID&p~'~e.bnex~eeiP(wj~.xe3.u~m;xedisnolo~.dl6iasi*bf6M~n¢vo,iunoa.xa~>4ebw7Aq.~mi~ai6nupmaeaor . eDndowd~aqmiod0£1ZQdrya. l+% .+~~:Y.y~..W:~..yu~..~c..p~.u~:..~.yu.~:y~wu:~wriwei~csaCl0~am0upLD~yY~p~.~pydCdDIIGEi➢~fdbWDOlL4RWIIlSemadem theoc~nlP~~md+P~~a~%~~YaoA+~%~vnx~twado~mtLnmta~wsadedmeP)Y~ TCOf~,uffiwDs~attffstlapenei~raetpuEpIDUCnt . . , owee&one(1)Y~wfu➢fmaL~db. wid 3eanwctr Y. (4) HOwoCCefm7o7w4CeLll6eddnegoLwillabMgaPoenuOV+lflowaEtrabreamft fmnvpprehLm- (51 CmRae.~eDaIIaoG4'MBd~OP~~'~Y-~~7~aiu+Mm~sSaaIlioapxtlpptauC~aRaecdvee/d~a *uM F~.:~. ~'ilrmimpeefieotcmdLdp~ p~asee3~.e WM wnn.~eriR. . (5~ ThaislL~eeoSaPC~it~tDeappmvala€ttravc'ingB~dyyp~~jpiM1i~6~]imtEeans4nalbbeaPa~[me,nora¢~YWord~LmYtid+soaot&~ ~ tflh?be+~'othvm~mnoqlaw, rviavaeguLtig, . I TO'd iS: iti £OOL 6L aclti LS8ZS£Z£0£: Xpj md 2 JNINNb9d Porcello Engineering 6830 North Broadwny. Suite G. Denver, Colorado 80231 Phone 303.412.8900 Fax 303.412.8999 www.PEI-Engr.com May 13, 2003 Mr. James Kinsman Kinsman Construction 399 South Harrison Street Denver, CO 80209 Re: Open Hole Inspection 2970 Upham Street, Denver, CO Dear Mr. Kinsman, On May 12, 2003, I performed an open-hole inspection of the footing for the addition at the above referenced residence. Based on my visual observations, the footing appeared to be free of expansive clays and is adequate for a spread-footing type foundation An allowable soil bearing pressure of 1000 psf should not be exceeded. I recommend a 16-inch wide by 6-inch thick footer be placed beneath an 8-inch concrete foundation wall. See attached details for dimensioning and reinforcing steel placement. All other aspects of constmction that are not detailed in this letter must follow current building code for the jurisdiction in which permits are issued. If you should have any questions, please contact me at 303.412.8900. Sincerely, Christopher Porcello, PE ~pGO RE~~ Z:,. ~o~.•;~j~E;i ~3 . t „\p O~•. :R 35670 ~ol Porcello Engineering 6830 North Broadway. Suite G, Deriver, Colorado 80221 Phone 303.412.8900 Fax 303.412.8949 www.PEI-Engr.com 1/2" GYP. BOARD NOTE: ADEQUATE DRAINAGE SHALL BE PROVIDED AROUND PERIMTER OF FOUNDATION. SLOPE SOIL 1/2' PER FOOT FOR FIRST 5-FT. SIDING TO MATCH - EXISTING 1/2" OSB SHEATHING 1xt2 RIM JOIST z ~ FINISHED~ ~ GRADE 2x's @ 16" O.C. R-13 BATT INSULATION 2x SILL PLATE 7/8" SHEATHING (MIN.) FLOOR JOISTS @ 76" O.C. 2x8 SILL PLATE Z (2) #5's CONT. F io #5's @ 18" O.C. ~ 1/2'0 J-BOLT ~ SEE DETAIL 2/S2 z ~ 8" CONC. WALL - ° #5's @ 18' O.C. ALT. HOOKS @ EVERY OTHER BAR c~ (2) #5's CONT. #4's (d) 18" O.C. FOUNDATION DETAIL SCALE: NTS 35670 ^EPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 12808 BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE Date : 9/18/01 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner : Property Address : 2970 UPHAM ST Phone : 344-1259 Contractor License No. : 18146 Company : McBride Electric Phone : 303761-6176 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the Cify of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all wnditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.CJ and all other applicable Whe Ro ge or ~inan for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE % 4 01 Construction Value : $2,200.00 Permit Fee : $8325 Plan Review Fee : $0.00 Use Tax : $33.00 Total: $116.25 Use: Description : 200 AMP CHANGE OF SERVICE BUILDING DEPARTMENT USE ONLY ~~024* SIC ~;rr.c. r, Approval : Zoning : Approval : Approval : Occupancy : Walls Electrical License No : 18146 Company :McBride Electric Expiration Date : 4/27/02 Approval : OK/KS Roof : Stories Plumbing License No : Company: Expiration Date : Approval: Sq. Ft. : Residential Units : Mechanical License No : Company : Expiration Date : Approval : (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Coloretlo and to the Zoning Regulations and Building Cotle of Wheat Ridge, Colorado or any other applicable ordinances of fhe City (2) This permit shall expire iF (A) the work authorized is not commencetl within sixry (60) days from issue tlate or (B) the building authorized is suspentled or ahantloned for a period of 120 tlays. (3) If this permit ezpires, a new permit may be arquired for a fee of one-half the amount normally requireQ provided no changes have been or wiil be made in the original plans antl specifcations and any suspension or abandonment has not exceetled one (1) year. If changes are made or if suspension or abantlonment exceeds one (1) year, full fees shall be paitl for a new permit. (4) No work of any manner shall be tlone that will change the naturel Flow of water causing a draina9e problem. (5) Contractor shall notify the Builtling Inspector hventy-four (24) hours in atlvance for all inspections and shall receive written approval on inspection card before roceediing with successive phases of the1ob. (6) issuance o permit or the approval of drewings and specifcations shall not he consirued to be a permit for, nor an approval o( any violation of the provisions f t e bjkJjqq~tles or any other ordinance, law, rule or regula6on. Inspector Jan-25-99 04:54P DEVREVFAX 303 235 2857 P.02 DEPARTMENT OF PLANNING AND DEVELOPM[ NT Building Permit Number : BUILDING IN3PECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 qppLICATIo N PropertyOwner: Property Address : a q~0 Uh a.,.. . Phone : 3u 3 - 3 yv- /as5 ConVactor License No. : Company : 1vk Phone : ~1~c rZ J-„~~. OWNER/CONTRACTOR SIGNATURE OF uNOERSTaNnwr, nun nr.aF =RectiT I Aereby eertity t~et the eetbea{c dlatancee proposetl by thia pertnit applintion aro a: ,urate , entl tlo not violele epplfcebla oMinanees, ruba ot regul 'ona ot the City of Wheat RI ge or covenanta, easements or rostrictions of record; that all made arc eccurate; that I heve reatl and a ree to ebid epplication and that I aasume }uil reaponsi Iity for co eeauromenb shown, and i~ eqttlons yall condRlons printed on U ia lianee wtth M Wh i , Code (U.B.C.) and all other applkabh Wh t RW e o e eat R dg[ BuIlCing nancea t r k d Mf p , o wor un ar s I armk. (ONMER)(CONTRACTOR) SIGNED pq7p Construction Value : ) a vo % Permit Fee : Use Tax : Use: Description : a p v /T~.P 1 CCIS v-4 BUILDING DEPARTMEN'f USE ONLY SIC : Approval: Zoning : Approval : Total : F' er ^ St~. ~ Sq. Ft. : Approval : Occupancy : Walls : Roof : 3tories : Residentlal Units : Electrical license No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: (t) Thle permlt was luuetl in axortlanae wim Ne pravisloru eet fiM In yoput applkatlon e d is wbikt to the Iswa of Ne State of Cdoretlo and ro IM 2onlrp Repuletlons and Bulltlirq Cotle W NAiaat RMOe Cobraao or siry otl+er appikaoie oraro iae M fhs Ciry. (2) Thlt psrmtt fiNl sxpin M(A1 tlh work sutl»rizatl ia net eommeneed wiUtln auny (e0) tlir s hom lasua Aate or (B) tl+e euildinp euMonzaf ia auapenaea a aDanCOnetl lor a perWE W 130 tlrye. (3) If thia parmN sxpiru, a new pvrrut may te ecquina ror e iee er ena.nan ft amounc ncn -uiy mquuae, oroviaea no a,anyes nave uean a win w mwe in ft orqinsl plana and Spsdllptbna and anry wspenelon a aban7onment Ms not exaaCe< one (1) yesr. If ehangea aro mstle w If wepenelon or eDanOOnment exaeetle one (1) yur, NII Nas MaIt bs paid for a naw peimit. No vrork ot arry menner shaY bs dons IMt wi4 change tM naNrfl Ibw of wa4r au6irq . Mineps Pro0lem. (S~ Controctor fMll no0ry Me BuilOirq Inaoeau nvenry.four (4q noun in aavan~e ror ail Im xctlons and shaii recaNe wrinen approval on impacaon ur0 bafom procaetlnnq with euxseMw phasn of t~a1ob. (B) ilie usuence M e pertMt or th~ eppmval a! dnwinpa and Weeilkatloro shall not De con Wetl ro Da a permX !w, nor an approvd of, any vblslion ol Ms prorisb of the bulltllnq codo or airy othM ortfinence, Iwv, Ma a reyuletbn. Chief Building Inspector T a t ~ ~ Z 0 ~ m O m ~ 2 ~ n ~ N ISC ~ ~ < 7' C ~ fD 07 r 0 ~ f°o e c o a a a ~ M CD M ~ N 0 (D 3 0 o 'r 01 y CL ~ C) O P ~ (n v ~ o ~ ir 8 . w . < n , ` J 0 c~ r- u II r-_I \ / m 0 1 0 w In 2 w m ul aN ~ N ~ cn v m C ~ v z ~ m D ~ ~ Z ~ DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) 12072 4/27/2001 Property Owner : Property Address : 2970 UPHAM ST Contractor License No. : Company: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certiry that the setback distances proposed by this percnit application are accurete, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibili for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheaf'Widge ordinyMices, pr)vork under this pe~rmit. / Description : 24' X 24' STEEL GARAGE BUILDING DEPARTMENT USE Approval : MLC COMPLIES WI R-1 REGS Zoning : R-1 Approval: BG e4P~I ,ff / L~ DATE~ 4I27/01 BUILDING MUST BE PROPERLY GROUNDED Building Permit Number Date Phone: 445-1259 Phone : Construction Value : $14,000.00 Permit Fee : $237.25 Plan Review Fee : $0.00 Use Tax : $350.00 Total: $587.25 Use: COllU3~ voIleWo;ut 03emm7JEU[1=43alT= s1o7lo uotlanASaoo ,Cue pnz 1as usid atp uiyly+ paultuqns uot7euuo3ui ammoeui io; olqisuodsu lou si d~l:) ayy 61uawanadwi 8ut10n4saw pw . pdsbj S! jopv*l/2 io3 o19& :a1oH actald Approval : Occupancy : Walls Roof Stories : Residential Units : Electrical License No : Company: Expiration Date : Approval : Plumbing License No : Company: Expiration Date : Approval: Mechanical License No : Company : Expiration Date : Approval : (1) This permit was issued in accortlance with the provisions set forth in yopur application and is subject to the laws oF ihe State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colo2do or any other applicable ordinances of the City. (2) This pertnit shall expire if (A) the work authorized is not commenced within siMy (80) days hom issue date or (B) the building authorizetl is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permil may be acquired for a fee of one-half the amount normally required, provitletl no changes have been or will be matle in the on9inal plans antl spenfications and any suspension or abantlonment has not exceedetl one (1) year. If changes are made or if suspension or abandonment exceeds one (7) year, fWl fees shall be paitl for a new pertnit. (4) No work of any manner shall be tlone that will change the naWral flow otwater causing a drainage problem. (5) Contractor shall notify the Builtling Inspector hventy-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the ob. (6) The iss ot a perm r the approval o~tlrawings and speci(ications shall not be construed to be a permit for, nor an approval of, any violation of the provisions o. i,d~ny ot0er oMinance, law, rule or re9ulation. Chief Building I pector DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CiTY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner: f~ia/L%ECr T Property Address : Z~IP C*/~ g ~ Contrectar License No. : A4 Phone : 3" ~/S/S-/259 Company : /L,r1 Phone OWNER/CONTRACTOR SIGNATURE OF UNOERSTANDING AND AGREcib1ENT I hereby certify that the set6ack tlistances proposed hy this oertnit aoplication are accurate, and Co not violate applicahle ordinances, rules or regulations of the Ciry of Wheat Ridge or -covenants, easements or restnctions of recortl: ehat all measurements shown, antl allegations made are accurate: that I have reatl and agre= ro abide by all contlitions ornted on ;his aoplicaticn, and that I assume tull responsibiliry for compliance with the Wheat Ridge 8uilding Code (U.B.C.) antl all other applicable Wheat fte ortlinan s, for wo under this perm (OWNER)(CONTRACTOR) SIGNED_"~1~"'_`~ DATE 1 G~ Cescrption : ;2 'y'Z q Building Permit Number : Date : e e : x : : [7Total Use: BUILDING DEPARTMENT USE ONL Y : ~ comp~ `~'R~ ~ ~oc~s s~~ Approval : i1~.~ Zoning : Approval : W/>7~e) A Approval : Occupancy : V`✓alls Electrical License No : Company : Expiration Date : Approval : Roor : Stories : Residential Units : Piumbing Licens2 No : Mechanical License No : Company : Company : Expiration Date : Expiration Date : Approval: Approval: ~ (1) This pertnit was isSUeC in accortlance wiN fhe provisions set foM in yopur applicauan antl is 5u0ject ta Ibe laws of the Stale of Cola2do antl to Ne Zoning Regulafions and HuilGing Coae of Wheat RiEge, CofloaCo or arry other applicable orGinances of Ne Ciry. (2) This pertnit shall expire J(A) Ne work authonzed is nat wmmencea wiNin sixty (60) aays hom issue aate or (B) Ne Ouiltling autlionzeG is susper4ea or abandonetl lor a penoC o! 120 Cays. If this oertnit expires, a new pertnit may Oe acpuireC for a fee of one-nalf tne amaunt nortnally reduirea. pmviaeE no cnanges nave oeen or will Oe maCe in t0e onginal plans anG speuficaUOns anG any suspension or aOanEOnment has not exceeded one (1) year. If cnanges are matle or ii suspension or abandonment exceeds one (1) year, /ull lees shall be paiC !or a new permit. (a) No work of any manner shall Oe tlone Nal will Uange ihe natu2l 11ow ol water tausing a tlrainage proGlem. (5) Convactor shall notl/y the BuilEing Inspector twenry-four (24) hours in atlvance !or all inspections antl shail receive wntten aoproval an inspection card bebre pmceeCiing with sutcessive pnases ot the jo0. (6) The issuance o( a permit or Ne approval o( tl2wings antl 5peuficaGons shall not be conSWeC lo be a pertnit lor, nor an appmval oC any violation o( Ne provisions of Ihe CuilCing codes or any ot0er ortlinance, law, tule or requla0on. --~/q/~(r~+ . Chief Bwlding Insector Sq. Ft.C',~"! .~9 0 i I , 3'DNECIIS3'8!4 Wb'H1Nb'z1 ~ s ~u ! I~ .VE G~.6'. ' I b ~ I I I d o 1 I I I 1 I 1 I ~ll l i~ ul ~ A'1 . I) III d'~ u \ Z W uI ii ui C) U' i i i i i- 1 ^ ' . . ~I I . ' ~ I . b I I'. . . ~ . . ~ . . . ' ' - - - ~~i~ i ~ ~ c I I I »ca~ w~avrre . • .c-s ~ I ~ A~yV o. JU (I s'll :t II a sn, WT;eat ..:~4 Ridge e . Plan Checker X-BRACE THIS BAY ^N N ~ E ^ 0 lV V T l~J U Z 0 U v i o I O O t- O I N V " I 0 A C 2 ®1® AB3 AB3 C 1 ® ® A83 E 1 AB3 ® ® AB3 ®l® AB3 C 1 C Z AB3 X-BRACE THIS BAY h 23-4" i 24'-3" OUT TO OUT CONCRETE ANCHOR BOLT SETTING PLAN AB_ DENOTES ANCHOR BOLT SIZE, 0 DENOTES ANCHOR BOLT DETAIL S2" r m N ~ V I W U ^ 6 m x 3101 SHLLI ~/o~ Al OF 3 2X 04° ANCHOR BOLTS N OMIT NOTCH AT OPENING J J 3 0 z 2X 04° ANCHOR BOLTS DETAIL D BASE: 3 112" X 8" (TYP) 51" 2 4" 2° J a 3 0 z Lil x 04" CHOR BOLTS rN i DETAIL C1 BASE: 8" X 8 112" (TYP) J wJ 3 i . 4., DETAIL E1 BASE: 6 112" X 8" (TYP) 52` 2X 04" 4° ANCHOR BOLTS N L_ _J J J a 0 z ~ N SIDEWALL 12. ACCESSORY SCHEDULE MARK DESCRIPTION DETAIL QTY 1 16'-0" X 8'-0" FRAMED OPENING A 1 N/A 3070 SELF FRAMING WALK DOOR W1 1 N/A 4030 HORIZ. SLIDE WINDOW/INSULATED N/A 1 PERIMETER BOTCH DETAIL OMIT AT DOOR OPENING AND AS SHOWN O L.ON ANC.,'R BOLT SETTING ~G PLAN 2X 02" SELF FRAMING 3070 WALK DOOR (FIELD LOCATE) DETAIL C2 BASE: 6 112" X 8" (TYP) DETAIL W1 BASE: 2 112" X 8" t ~•B~ ANCHOR BOLT SCHEDULE a NUT 4 MARK QTY DIA A B PROJ. AB3 14 3/4" 2 1/2" 2 112" 2" N/A 4 1/2" EXPANSION ANCHORS A-307 ANCHOR BOLT I GENERAL NOTES 1. ANCHOR BOLTS AND OTHER EMBEDDED ITEMS ARE NOT BY ATY BUILDING SYSTEMS, INC. 2. FOUNDATION DESIGN & ANY OTHER CONCRETE DESIGN WORK IS NOT BY ATY BUILDING SYSTEMS, INC. (CONSULT A LOCAL ENGINEER FOR THE DESIGN OF THE FOUNDATION AND OTHER CONCRETE WORK). 3. BASE PLATES ARE DESIGNED ASSUMING THAT CONCRETE HAS A MINIMUM STRENGTH OF 3000 psi AT 28 DAYS. I MATERIAL SPECIFICATIONS I 1. ALL FLANGE MATERIAL IS 50 KSI 2. ALL BASE PLATE MATERIAL IS 50 KSI 3. ALL WEB MATERIAL IS 50 KSI 4. ALL HOT ROLLED MILL SHAPE IS 50 KSI 5. ALL COLD-FORMED MATERIAL IS MIN. 55 KSI DESIGN CRITERIA BUILDING CODE: UBC97 SNOW IMP. FACTOR: 1.00 WIND IMP. FACTOR: 1.00 LIVE LOAD: 30.00 PSF LOAD REDUCTION: NO GROUND SNOW:42.86PSF ROOF SNOW: 30.00 PSF DEAD LOAD: ACT. PSF COLLATERAL LOAD: 0.00 PSF WIND VELOCITY: 100.00 MPH EXPOSURE CODE: B OPEN CONDITION: ENCLOSED SEISMIC ZONE: 1 SEISMIC IMP. FACTOR:1.00 (SOIL PROFILE = SD - UNKNOWN) (SEISMIC PROCEDURE UTILIZED - STATIC FORCE PROCEDURE) JOB#: 00-2040 BY: RN DATE: 1/9/01 SHEET DAN GRANTHAM CK: DATE: / I d A2 OF 3 SIDEWALL REACTION DUE 10 CABLE BRACING FRONT & BACK SIDEWALL: (DL+WL) RIGHT ENDWALL: 1.30 K 1.24 K 1.5 K 2.4 K a z ~o o ~ HL I VL 0 i 0 HR ~VR 24'-0" FRAME LINE 1 LOADINGS COLUMN REACTIONS (KIPS) HL VL NR VR Dl 0.15 0.65 0.15 0.65 LL 1.22 4.32 1.22 4.32 SL 1.22 4.32 1.22 4.32 WLL -1.83 -2.16 0.65 -1.04 WLR 0.65 -1.04 -1.83 -2.16 WEW 0.14 -1.60 0.14 -1.60 SEIL -0.11 -0.07 0.11 0.07 SEIR 0.11 0.07 -0.11 -0.07 DL+LL 1.37 4.97 1.37 4.97 Dl+SL 1.37 4.97 1.37 4.97 OL+WLL -1.68 -1.51 0.80 -0.38 OL+WLR 0.80 -0.38 -1.68 -1.51 DL+WEW Q29 -0.95 0.29 -0.95 12,((x0 12.00 of IC> O 0 0 0 12.00 oI 0 12.00 0 0 24'-0" ENDWALL AT FRAME LINE 1 COLUMN REACTIONS APPLIED I LINE #B I LINE #D LOAD CASES AND I HORIZ VERT I HORIZ VERT COMBINATIONS I (KIPS) (KIPS) I (KIPS) (KIPS)I ------I DL I .00 I .03 .00 .03 LL .00 .00 .00 .00 SL .00 .00 .00 .00 WL+ .61 .00 .61 .00 WL- -.38 .00 -.38 .00 DL + WL+ .61 .03 .61 .03 DL + WL- -.38 .03 -.38 .03 DL + UBL .00 .03 .00 .03 DL + UBR .00 .03 .00 .03 BY. RN DATE: 1/9/01 SHEET CK: DATE: / / A3 OF 3 c=D HA t VA VA F VE E 12'-0" 24'-0" ENDWALL AT FRAME LINE 2 COLUMN REACTIONS M APP LIED I LINE #A I - LINE #C I LINE #E I LOA D CASES AND I HORIZ VERT I HORIZ VERT I HORIZ V ERT I COM BINATIONS I (KIPS) (KIPS) I - (KIPS) (KIPS) I I- (KIPS) (K IPS)I ----I DL I .00 I .15 .00 .43 .00 .15 LL .00 1.63 .00 5.42 .00 1.63 SL .00 1.63 .00 5.42 .00 1.63 WL+ .36 -.60 .79 -2.01 .36 -.60 WL- -.22 -.60 -.49 -2.01 -.22 -.60 DL + LL .00 1.77 .00 5.84 .00 1.77 DL + SL .00 1.77 .00 5.84 .00 1.77 DL + WL+ .36 -.46 .79 -1.59 .36 -.46 DL + WL- -.22 -.46 -.49 -1.59 -.22 -.46 DL + SL + 1/2WL+ .18 1.47 .39 4.84 .18 1.47 DL + SL + 1/2WL- -.11 1.47 -.25 4.84 -.11 1.47 DL + 1/2SL + WL+ .36 .35 .79 1.12 .36 .35 DL + 1/2SL + WL- -.22 .35 -.49 1.12 -.22 .35 DL + UBL .00 .82 .00 4.49 .00 1.91 DL + UBR .00 1.91 .00 4.49 .00 .82 B D B D 14'-0' 16'-0' 4'-0" VC C 12'-0" I 12.00 12.00 0 0 12.00 12.00 1.00 ~ ~ 1.00 12'-02 12 -OZ " ttiii, 01„ 5.0» 1-01`6 1-016 5'-0" 3'_0 2'-119„ 2 -1116 - 4 4 16 co N O O I I ~ O I PLATE SIZE TABLE SPLICE BOLT TABLE CONN. LEFT SIDE RIGHT SIDE SPLICE CITY SIZE TYPE A 8"X "X 82. N/A A 2 3. A301 B&N B 6" X" X 1-24 6' X" X 1-24 B 8 q' X I4" A325 B&N C 6' X" X -24 6' X" X -24 C 8 a' X 14 A325 B&N D 6' X" X V-23- 6' X X 1'-24 D 8 4' X 14 A325 B&N E X 81• N/A E 2 A307 B&N FB- FB- F8- FB- ca R X R-X XI XI U U VERTICAL CLEARANCE AT LEFT HAUNCH = 8'-8 g" 82 VERTICAL CLEARANCE AT RIGHT HAUNCH = 8'-8$" 82 VERTICAL CLEARANCE AT PEAK = 9'-4A" HORIZONTAL CLEARANCE HAUNCH TO HAUNCH = 21'-2" 12'-0" 12'-0" I 24'-0" OUT/OUT STEEL A E CROSS SECTION AT FRAME LINE 1 00 N O ~ O O d- w s a.R i 0 JOBS: 00-2040 BY. RN DATE: 1/9/01 SHEET DAN GRANTHAM CK: DATE: r iDl El Of 6 FS- L r C r r c c ROOF FRAMING PLAN h i 1 1 SYSTEMS swc~ JOB#: 00-2040 BY: RN DATE: 1/9/01 DAN GRANTHAM CK:~ DATE: V-/ x!®!; ES- = N \ / \ G / / C-D /G \ \SCB. W ' N BA 1 N N \ - \ 'CX CC- ' EQ EQ EQ EQ 4" 23'-4" 4" 1 2 24'-O"OUT f OUT STEEL SIDEWALL FRAMING ELEVATION AT LINE A ES- C~o N \ G \ C-D w \ BA-1 N CC- C-X ' EQ EQ EQ EQ 4" 23'-4" 4" 2 1 24'-0"OUT/OUT STEEL SIDEWALL FRAMING ELEVATION AT LIRE E R X R_X N ~I -----oH------- I~ f = I i o C-D CD II I I II II 01 0 10 II w II I I II BA-1 I I C-X EC EC-C C_X 8" 3'-4" 16'-0" 3'-4" 8" E ID CE iA 24'-0-OUT/OUT STEEL ENDWALL FRAMING ELEVATION AT LINE 1 [R- ER- co N c i c I I I ono CD > I ZG I 0 I w BA-1 C J ] C - EC- CC- 8" 11'-4" 1l'-4" 8" A C E 24'-0-OUT/OUT STEEL ENDWALL FRAMING ELEVATION AT LINE 2 w; ~ I w Cr- 00 FL- 0 CY w Cif CXD ROOF SHEETING PLAN FL- a o I " SIDLDNAEL SHEETING ELEVATION AT LINE A A 1 5 STE MS'wcC A. TY . JOB#: 00-2040 BY. RN DATE: 1/9/01 SHEET DAN GRANTHAM CK DATE: / 01: ES OF f FL- FL- FL- ~ FL + FL,_ ~ ~-IN •-IN ~-IN O O r-IN GO co O N N N N O I J FL- r-,) I a o 00 SIDEWALL SHEETING ELEVATION AT LINE E I J I J ENDWALL SHEETING ELEVATION AT LINE 2uw 0 0 ATY ! SYST MSG A JOBS: 00-2040 A BY: RN DATE: 1/9/01 SHEET DAN GRANTHAM CK. DATE: ! ! p! E6 01 6 I J li FL- FL- + FL- ENDWALL SHEETING ELEVATION AT LINE 1 May-29-96 08:42A DEVREVFAX 303 235 2857 P.02 DEPARTMENT OF PIANNING AND DEVELOPMENT BUILDING INSPECTION QIVISION - 235-2855 CITY OF WWEA7 RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : Date : 03/20/98 Properry Owner: DAN GRANTHAM Properry Address:2970 IIPHAM Phone: 445-1259 Contractor License No. : 17618 Company:GROSS-RHODE ExTERiaRS, ixC. Phone: 797-1777 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I herepy certiiY that tMe setback and do not violeSa applicablo orl coveaants, aasemants or nstrik mado are accurate; that I have appllcation, and that 1 assume f Code (U.B.C.) and all e!„er app (OWNER)(CONTRAC70R) SIGNEO STEPHEli H. GBi Description : REMOVE AND HAUI. tnis permit application are accurate, ationa of the Ciry of Wheet Ridge nr measarements shown, and allegelions ~ by all conditions printed on this ipliance with the Wheat Ridge Building finances, for work untler this permit. rE 03/20 98 ODE,C.R. E%ISTING CEDAR SHINGLES, Construction Value : 2699.90 Permit Fee : 75.50 plan Review Fee : Use Tax : 40.49 7otal : 115.99 THEN INSTALL NEFi FELT AND BUILDING DEPARTMENT USE ONLY 1101111111111 111;111,11111 . SIC . Sq. Ft. ; 1923.00 Approval : Zoning : mingsomm Approval: mwsm~ Approval : pccupanCy ' Walls : Roof : Stories : Residential Units : EleCtrical LicenSe No : Plumbing License No : Mechanical License No : Company: Company: Company: Expiration pate : Expiration Date : Expiration Date : Approval: Approval: Approval: ~ ~ ~ Is mumassowmg ( q ihie parmit was bsued in sccordance wAh Ne Drovieions cel forth in yoDUr ap0lication and is sub1ect to the lews of lhe Slaie of Cdoratlo an0 M the Zoninq Requlationb and BVlWInp Cads of ~+eet Ridya, Cobredo or any otner applicable orqmancee of Me Ci(y (2) TI118 0@rmR shall EXplre If (A)1h8 Wofk authonzetl i5 noi ccmmenCeO wlthm sixfy (80) <Iays from issue date 0f (8) the buiWinp aulhodzed is suspentletl or ahaatloned Por a perWtl of 120 deya. (9) It Mis permil 6xOVes, a naw pelmit mey be arAUireC for a foe of one-hell the amoum normally reqafred, proWded no Changes heve 6a0n or w111 he made in the Oflqlnal plens antl ipeaificahont dn0 any euspeM151on or e6sndonment bea not enren0ed one (1) year. II Changee ere matlE 0r if suepencion 01 a0antlonrtrent exeEe09 One (1) yaif, IUII feac ihill Oe pDid (or a new permit. 4) Na work of any manner tbAll be done thal will chanpe fha natuml flow ofwater caueing a drainaqe Pro61em. ~5) Connector sMill nOtMy Ne BullOing Ineuxtor IWEnty-four (24) 110Ur3 in edvarlCe 10r eff inepections a00 9hall raceiv0 wfllien approval an inspk~on card bEfpre proeeeoiiny wNh tuettsaive vhases ol We'wb. 1e1 Tha iasuanC! of e permA o~ the epprovYl 0~ tlrewings an0 9pecifications snall not be c,nSVUed to he a permit for, rwr an appioval nf, any vioWlion o<<he provisbne of lhe 6uildlnq C0089 a any Oltllr adinallCG. Iaw, rule or fGqUletron. Chiet Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION