Loading...
HomeMy WebLinkAbout4481 Upham Streeti _CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspectiom_Ti_ ,� AM/PM > Re -Inspection required: Ye6 No *Wher http✓/ Me 1* � I i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: f - Job Address: `'�` r'/ & Permit Number: 'gyp Z ,,07 [� / ❑ No one available for inspection: Time ` - M PM Re -Inspection required: Yes 6"o When corrections have been made, schedule for re -inspection online at: h ttp://www. ci. whea fridge. co. urns pection Date: i/ ` ` Inspector:_ DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: !2 a ,i ❑ No one available for inspection: Tim Re -Inspection required;,'Yes No When corrections have been made, s edule i http✓/www.ci.wheatridge.co.uslinspectio \ r Datil. , ZOZ-6i online at: i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: /" F / Job Address - Permit t1 <<r�a-� moi` Permit Number: r 5 r r� ❑ No one available for inspection: Time� M/PM Re -Inspection required: , Ales) No When corrections have been made, schedule for re -inspection online at: http:Owww.ci. wheatridge.co. usrnspection Date: Pp Z9 -20.?o Inspector: -5)"40 DO NOT REMOVE THIS NOTICE � ► � i City of Wheat Ridge -.A Residential Mechanical PERMIT - 202002217 PERMIT NO: 202002217 ISSUED: 10/28/2020 JOB ADDRESS: 4481 Upham St EXPIRES: 10/28/2021 JOB DESCRIPTION: Replace 60K BTU, 80% efficiency gas furnace in crawl space ; Repalce 2.5 ton, 16 SEER AC in backyard *** CONTACTS *** OWNER (303) 949-5876 HAHN SCOTT W SUB (720)900-1188 JUSTIN MERYHEW 180164 TRUE HEATING AND COOLING *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 14,000.00 FEES A/C Replacement 60.00 Furnace Replacement 40.00 Total Valuation 0.00 Use Tax 294.00 ** TOTAL ** 394.00 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. 1* � � i City of Wheat Ridge -.A Residential Mechanical PERMIT - 202002217 PERMIT NO: 202002217 ISSUED: 10/28/2020 JOB ADDRESS: 4481 Upham St EXPIRES: 10/28/2021 JOB DESCRIPTION: Replace 60K BTU, 80% efficiency gas furnace in crawlspace; Repalce 2.5 ton, 16 SEER AC in backyard I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Air Conditioner/Evaporative Cooler Permit Application Date: Tuesday, October 27, 2020 7:42:57 PM Air Conditioner/Evaporative Cooler Permit Application This application is exclusively for AIR CONDITIONER OR EVAPORATIVE COOLER. YOU MUST ATTACH THE ELECTRONIC PAYMENT FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Is this a new install or Replacement of Existing Unit replacement for an existing AC unit? Is this Residential or Residential Commercial? Property Address 4481 Upham St. Property Owner Name Scott Hahn Property Owner Phone 303-949-5876 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email hahncreations@gmail.com Address Attach City of Wheat Electronic Payment Form - Revised 5-1-20 Ridge Electronic Fillable 20200501162001384920200608 Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTRACTOR INFORMATION Contractor Business True Heating and Cooling Name Contractor's License 12345 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 720-900-1188 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email Service@trueheatingcolorado.com Address Retype Contractor service@trueheatingcolorado.com Email Address DESCRIPTION OF WORK What type of Air Conditioner replacement unit are you installing? How many tons is the 2.5 unit? For AC - what is the 16 SEER? For Evaporative Coolers, what is the CFMs? Where is the unit Backyard located (for example, rooftop, backyard on ground etc)? Is electrical needed for No re -hook? Project Value (contract 14000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Justin MEryhew Permit Email not displaying correctly? View it in your browser. From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Furnace/Boiler Replacement Permit Application Date: Tuesday, October 27, 2020 7:40:09 PM Furnace/Boiler Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or BOILER - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes replacement residential furnace or boiler like for like? PROPERTY INFORMATION Is this Residential or Residential Commercial? Property Address 4481 Upham St. Property Owner Name Scott Hahn Property Owner Phone 303-949-5876 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email hahncreations@gmail.com Address Attach City of Wheat Electronic Payment Form - Revised 5-1-20 Ridge Electronic Fillable 202005011620013849 202006081141368198.Ddf Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTRACTOR INFORMATION Contractor Business True Heating and Cooling Name Contractor's License 12345 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 720-900-1188 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email service@trueheatingcolorado.com Address Retype Contractor service@trueheatingcolorado.com Email Address DESCRIPTION OF WORK What type of unit is Furnace being installed? Number of BTUs 66,000 What is the efficiency 80 (%) of the unit? Is the unit GAS or Gas ELECTRIC? Where is the furnace or crawlspace boiler located (for example, basement, crawlspace, etc)? Project Value (contract 14000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Justin Meryhew Permit Email not displaying correctly? View it in your browser. 1t't vt A i CITY OF WHEAT RIDGE t Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3®6-417 ,drv0,( Job Address:���l1�I U2►r,at. S-1, Permit Number: ? 01, ❑ No one available for inspection: Time f ' z A rte; �— Re-Inspection required: Yes I1 qo When corrections have been made, call for re -inspection at 303 -234 - Date:. I i! IL0116 Inspector:34v)f, 4ve.t DO NOT REMOVE THIS NOTICE POLYFLEX" SA BASE PRODUCT DESCRIPTION Polyflex° SA Base is a premium, self -adhered base ply roofing membrane. Polyflex SA Base is specifically designed to be used as a base sheet for heat welded roofing assemblies. Polyflex SA Base is constructed with a black mineral surfaced APP weathering compound, uniquely formulated to provide for exceptional bonding to heat welded interply or cap Sheets. The membrane is reinforced with a high performance fiberglass mat. Polyflex SA Base is manufactured using patent pending ADESO Dual -Compound Self -Adhesive technology providing for an aggressive self-adhesive compound on the bottom layer. Polyflex SA Base has a split release film for ease and safe application to approved substrates. Polyflex SA Base is packaged in a patented EasyBox that facilitates easy handling of the rolls, each roll provides for approximately 200 square feet of coverage and weighs approximately 70 pounds. USES • Designed as a base sheet for multi -ply, heat welded, modified bitumen roof systems • Compound formulated to provide exceptional bonding to APP mid -ply and cap sheets • Self -adhered for safe applications where using a propane torch is undesirable or prohibited FEATURES AND BENEFITS • Excellent long term adhesion and product performance • Fiberglass reinforced for exceptional dimensional stability • Low temp flexibility, puncture and tear resistant TECHNICAL DESCRIPTION METHODTEST PROPERTY VALUE ASTM D5147 Thickness, min, mm (mils) 1 .5 (60) Maximum Load @ 23+/-2'C (73.4+/-3.6°F), ASTM D5147 4.4 (25) MD and XMD, min, kN/m (Ibf/in.) Elongation at break 23+/-2'C (73.4+/ ASTM DS 147 10% 3.6°F), MD and XMD, min (%) ASTM D5147 Adhesion to Plywood, min at 40°F, Ibf/ft width 2.0 ASTM D5147 Adhesion to Plywood, min at 75°F, Ibf/ft width 12.0 ASTM D5147 Tear resistance N(Ibf) 89 (20) ASTM D5147 Sealability around nail pass Waterproof integrity after low temp ASTM D5147 flexibility pass ASTM D5147 Waterproof integrity of lap seam pass ASTM D5147 Slip Resistance pass �.40ES0` PRODUCT DATA Coverage (Nominal) ..................... 200 sq h Weight (Approx) .............................. 70 lbs Roll Size ...........66' 8" x 39 3/8° (20m x 1 m) Rolls/Pallet.......................................... 20 APPLICABLE STANDARDS • ASTM D 1970 • ICC ESR -2018 (pending) • UL Classified for use in class A, B or C roofs, as listed the latest UL "Roofing Materials and Systems Directory" t71 CC c 4L ut PRODUCT WARRANTY Polyglass USA, Inc. commercial roofing membranes can be backed with a manufacturer's warranty for up to 20 years when used as part of an approved, multiply roofing system. Please see your Polyglass USA, Inc. Sales or Technical Representative for specifications and details. ROOFING AND WATERPROOFING SYSTEMS G R O U P 0uP /J G / f4w ;4z / 1-800-222-9782 www.polyglass.com POLYFLEXuRSA BASE APPLICATION INSTRUCTIONS Polyflex SA Base is intended to be used as a base sheet for new or re -roof applications when applied to acceptable insulations and/or coverboards for commercial and residential structures. Polyflex SA Base is not recommended for direct adhesion to plywood sheathing on low -sloped roofs, however, it may be applied directly to approved wood deck substrates of non - occupied spaces such as carports, sheds, canopies, etc. • Apply only when the weather and forecast is dry and the ambient air temperature and substrate is 40°F (5°C) and rising. • Apply over clean, dry, dust and debris free substrates. Prime concrete decks prior to application with PG 100 Asphalt Primer. • When re -roofing, remove all prior roofing materials down to a clean debris free substrate and properly close off all abandoned roof penetrations. • Concrete or Steel decks shall be designed with proper expansion devices. • Wood decks shall be properly supported by the structural framing. • Ensure the installation of Polyflex SA Base does not prevent the ventilation of existing construction • Do not apply over shingles or other granulated surface. • While installing Polyflex SA Base: 1. Start at the low point of the roof. 2. Unroll the material and allow to relax. 3. Start by removing the first 18-24" of release film. 4. Press the membrane into place with firm and even pressure. Roll the edges with a silicone hand roller to ensure complete adhesion. 5. Gradually remove the remaining release film applying pressure from the center to the edges as you go. 6. Position successive rolls providing a minimum 6" end lap and 4" side lap. Laps can be sealed for additional water tightness with a hot air welder. 7. Roll with an 80# split -face linoleum roller. Take care on sloped roofs by securing the roller and applicator with the appropriate safety equipment. • End laps, T -joints, details and flashing may be installed using Polyflex SA Base with a hot air welder or with PG 500 or Polyplus 50 modified products. Check project details for proper installation requirements. POLYGLASS U.S.A., INC. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1 1 1 1 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.com General Line: (888) 410-13 75 19541233-1330 Customer Service: (8001222-9782 Technical Service: (866) 802-8017 Questions? technical@polygloss.com Product Disclaimer: Unless otherwise incorporated into or part of a supplemental manufacturer's warranty, Polyglass warrants its product(s) against manufacturing defects in its product that directly results in leakage for a period of 2 years. ROOFING AND WATERPROOFING SYSTEMS Refer to material safety data sheet (MSDS) for specific data and handling of our products. All • ► data furnished refers to standard production and is given in good faith within the applicable manufacturing and testing tolerances. &MAPF) R O U P Polyglass U.S.A., Inc., reserves the right to improve and change its products at any time with -s ✓ / out prior notice. Polyglass U.S.A., Inc. cannot be held responsible for the use of its products under conditions beyond its own control. 1-800-222-9782 For most current product data and warranty information, visit www,polyglass.com www.polyglass.com ELASTOFLEX@ SA P FR PRODUCT DESCRIPTION Elastoflex SA P FR membranes are premium, self -adhered elastomeric roofing products with a fire retardant additive, manufactured using patented ADESO° Dual -Compound Self -Adhesive technology, whereby a "true" SBS polymer modified asphalt compound is applied on the top layer and an aggressive self-adhesive compound is applied on the bottom layer. Elastoflex SA P FR membranes are built with a high performance reinforced polyester mat to ensure excellent dimensional stability. Elastoflex SA P FR membranes are finished with granules on the top surface and features patented FASTLap® as well as SEALLap®, a factory applied adhesive treatment at the membrane overlap. Each of these patented features provide for greater ease of application as well as improved product performance. USES • Designed for applications where using a propane torch is undesirable or prohibited • Applications include new construction, re -roofing and BUR repair installation • As a flashing membrane in all applicable specifications FEATURES AND BENEFITS • Excellent long-term adhesion and application to multiple substrates and base plies • Exceptional physical properties and long-term weathering performance • UV stabilized long lasting granule surfacing in multiple colors TECHNICAL DESCRIPTION METHODTEST ASTM D5147 PROPERTY Thickness, typical, mm (mils) TYPICAL VALUE 3.5 (140) ASTM D5147 Peak Load @ 23+/-2°C (73.4+/-3.6°F), MD and XMD, min, kN/m (Ibf/in.) 8.8(50) ASTM D5147 Elongation @ 23+/-2'C (73.4+/-3.6°F), MD and XMD, min I%) 35 ASTM D5147 Tear Strength @ 23+/-2'C (73.4+/-3.6°F), min, N (Ibf► 246 (55) ASTM D5147 Low Temperature Flexibility, max, °C (°F) -18(0) ASTM D5147 Granule Embedment, max, g 2 ASTM D1970 Adhesion to Plywood @ 407, min, Ibf/ft width 2.0 ASTM D1970 Adhesion to Plywood @ 757, min, Ibf/ft width 12.0 ASTM D1970 Sealability around nail pass ASTM D1970 Waterproof integrity after low temp flexibility pass ASTM D1970 Waterproof integrity of lap seam pass AVAILABLE COLORS Top surface granule protection is available in a variety of colors such as: Black Buff Chestnut Grey Slate Oak White Red Blend Pine Green Heather Blend Weatherwood Copyright 02011 by Polyglass J.5 A., Inc. and all rights are reserved Edition Date: 12/11 • Doc# Elastoflex SA P FR PRODUCT DATA Coverage (Nominal) ..................... 100 sq ft Weight (Approx)..............................90 lbs Roll Size ..........32' 10" x 39 -'/g" (l Om x 1 m) Rolls/Pallet........................................... 20 APPLICABLE STANDARDS • ASTM D 6164 Type I, D 1970 • Miami Dade Code Compliance • FM Factory Mutual Approved • UL Classified for use in class A, B or C roofs, as listed the latest UL "Roofing Materials and Systems Directory' • ICC ESR -2018 • Florida Building Code • TDI (�?� tqg <­> ys.,a ti °yam C`�L US PRODUCT WARRANTY Polyglass USA, Inc. commercial roofing membranes can be backed with a manufacturer's warranty for up to 20 years when used as part of an approved, multi -ply roofing system. Please see your Polyglass USA, Inc. Sales or Technical Representative for specifications and details. WATERPROOFING MATERIALS AND INSULATING SYSTEMS MAPE 1-800-222-9782 www.polyglass.com ELASTOFLEX@ SA P FR APPLICATION INSTRUCTIONS Elastoflex SA P FR is intended to be used as a cap sheet for new or re -roof applications as part of a multi -ply system when applied to acceptable insulations and/or coverboards for commercial and residential structures. Elastoflex SA P FR may also be applied directly to approved wood deck substrates of non -occupied spaces such as carports, sheds, canopies, etc. • Apply only when the weather and forecast is dry and the ambient air temperature and substrate is 40°F (5°C) and rising. • Apply over clean, dry, dust and debris -free substrates. Prime concrete decks prior to application with PG 100 Asphalt Primer. • When re -roofing, remove all prior roofing materials down to a clean debris -free substrate and properly close -off all abandoned roof penetrations. • Concrete or steel decks shall be designed with proper expansion devices. • Wood decks shall have all joints blocked and properly supported. • Ensure the installation of Elastoflex SA P FR does not prevent the ventilation of existing construction. • Do not apply over shingles or other granulated surface. • While installing Elastoflex SA P FR: 1. Start at the low point of the roof. 2. Unroll the material and allow to relax. 3. Start by removing the first 18-24" of release film. 4. Press the membrane into place with firm and even pressure. Roll the edges with a silicone hand roller to ensure complete adhesion. 5. Gradually remove the remaining release film applying pressure from the center to the edges as you go. 6. Position successive rolls providing a minimum 6" end lap and 4" side lap. Laps can be sealed for additional water tightness with a hot air welder. 7. After installation of the entire roof surface, roll with an 80# split -face linoleum roller. Take care on sloped roofs by securing the roller and applicator with the appropriate safety equipment. • Details and flashing may be installed using Elastoflex SA P FR with a hot air welder or with PG 500 Roof Cement. Check project details for proper installation requirements. POLYGLASS U.S.A., INC. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1 1 1 1 West Newport Center Drive Deerfield Beach, FL 33442 www.polygloss.com General Line: (888) 410-1375 (9541233-1330 Customer Service: (8001222-9782 Technical Service: (8661802-8017 Questions? technical@polyglass.com Product Disclaimer: Unless otherwise incorporated into or part of a supplemental manufacturers warranty, Polyglass warrants its product(s) against manufacturing defects in its product that directly results in leakage for a period of 5 years. WATERPROOFING MATERIALS AND INSULATING SYSTEMS Refer to material safety data sheet (MSDS) for specific data and handling of our products. All data furnished refers to standard production and is given in good faith within the applicable ;101 vtcl manufacturing and testing tolerances. &MAPET G R u P Polyglass U.S.A., Inc., reserves the right to improve and change its products at any time with- ' out prior notice. Polyglass U.S.A., Inc. cannot be held responsible for the use of its products �S7 Pe under conditions beyond its own control. 1-800-222-9782 For most current product data and warranty information, visit www.polyglass.com www.Polyglass.com City of Wheat Ridge r Residential Roofing PERMIT - 201802817 PERMIT NO: 201802817 ISSUED: 10/23/2018 JOB ADDRESS: 4481 Upham St EXPIRES: 10/23/2019 JOB DESCRIPTION: Reroof remove and install Polyglass in Heather Blend Color, Self Adhering Base and Cap Sheet (Modified Bitumen) and Malarkey Legacy IR Class 4 Arch Asphalt Shingles with 27 total squares, 5.5 squares flat and 21.5 squares pitched). Pitch 1.5/12, 5/12. House Only. *Installed to Manufacturer's Specifications for the Polyglass roofing system.* *** CONTACTS *** OWNER (303)949-5876 HAHN SCOTT W SUB (720)227-0555 Harry Kahn 110209 Falling Rocks Roofing, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11,595.74 FEES Total Valuation 0.00 Use Tax 243.51 Permit Fee 236.00 ** TOTAL ** 479.51 *** COMMENTS *** *** CONDITIONS *** midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201802817 PERMIT NO: 201802817 ISSUED: 10/23/2018 JOB ADDRESS: 4481 Upham St EXPIRES: 10/23/2019 JOB DESCRIPTION: Reroof remove and install Polyglass in Heather Blend Color, Self Adhering Base and Cap Sheet (Modified Bitumen) and Malarkey Legacy IR Class 4 Arch Asphalt Shingles with 27 total squares, 5.5 squares flat and 21.5 squares pitched). Pitch 1.5/12, 5/12. House Only. *Installed to Manufacturer's Specifications for the Polyglass roofing system.* I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the rope rty and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further t I am le all o include alI entities named within this document as parties to the work to be performed and tha t 1jie ed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180. days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or anvy ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. La enia Reimer From: no-reply@ci.wheatri dge.co.us Sent: Monday, October 22, 2018 4:18 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in 210 the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE' AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. The Building Division permit counter is open from 7:30 am to 3:30 pm, Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a residential roof? How many dwelling units are on the property? PROPERTY INFORMATIO Property Address Property Owner Name Yes N Single Family Home I I�[i �r1�Cr S 4- 4481 Upham St.��� Scott Hahn Property Owner Phone 303-949-5876 Number (enter WITH , dashes, eg 303-123-4567) �� Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract hahncreations@gmail.com Yes Hahn roof contract scan - 101818.pdf CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Falling Rocks Roofing 110209 720-227-0555 Contractor Address 3640 S. Jason St. (Primary address of your business) Contractor Email Address fallingrocksconstruction@gmail.com Retype Contractor Email fallingrocksconstruction@gmail.com Address DESCRIPTION OF WORK TOTAL SQUARES of 27 the entire scope of work: Project Value (contract 11595.74 value or cost of ALL materials and labor) Are you re -decking the No roof? Is the permit for a flat Flat roof (less than 2:12 pitch), Pitched roof (2:12 pitch or roof, pitched roof, or greater) Pki both? (check all that apply) What is the pitch of the 1.5/12 FLAT roof? How many squares are 5.5 part of the FLAT roof? Describe the roofing Polyglass in Heather Blend color material for the FLAT roof: Type of material for the Other (specify below) FLAT roof: If "Other" is selected Self Adhering Base and Cap sheet - mod bit above, describe here: What is the specific pitch 5/12 of the PITCHED roof? How many squares are 21.5 part of the PITCHED roof? Describe the roofing Malarkey Legacy IR Class 4 Arch Shingle materials for the PITCHED roof. Type of material for the Asphalt PITCHED roof. Provide any additional We are only doing the house roof detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. 3 I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Harry Kahn Permit Email not displaying correctly? View it in your browser. •� � � � �� � � � � Occupancy/Type 1 NSPECTIO RECOR O INSPECTION ONLINE FORM: p://www.ci.wheatridge.co.us/inspection INSPECTIO EST LWE: (303) 234-5933 l + r --t ho ciihmittarl via the onIinP form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector CommentsInitials Pier Electrical Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior 10 Approval yr I ne 1ALIVVC 11 IZIPWI, %J11-1 Underground/Slab Inspections Inspector Date Initials Comments Electrical Sewer Service Plumbing Lath / Wall Tie .. . _ __________ -1 __ 0_1_...11... 01 ..6 IAIIr Drinr Tn Or%r%rr►vnl L IT 1 hp Anove InSD@GLIVIIS UV IVVL VVVCI V111�c1 Rough Inspections Date Inspector CommentsInitials Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric " Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. e /Public Works Dept. ROW & Drainage p Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "_ r:-.. no,.+.:,.+ -4 ^10 +r;r 1 I—, ,n1tnnP *For low voltage permits - Hiease De sure inat ruuyn 11lZ5PVUL1U 1� a �, IN ­, �• - - - _ _.___ _-_ by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Plumbing PERMIT - 201706730 PERMIT NO: 201706730 ISSUED: 08/30/2017 JOB ADDRESS: 4481 Upham ST EXPIRES: 08/30/2018 JOB DESCRIPTION: Permit for emergency repair: repair sewer line about 10ft in yard only. INstall Dual sweep clean outs, squege for bedding. (Right of way permit separate) *** CONTACTS *** OWNER (303)949-5876 HAHN SCOTT W SUB (303)210-8207 Brandon Weston 110115 Premier Excavation Services *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,900.00 FEES Total Valuation 0.00 Use Tax 60.90 Permit Fee 93.35 ** TOTAL ** 154.25 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** PERMIT NO: JOB ADDRESS: JOB DESCRIPTION City of Wheat Ridge Residential Plumbing PERMIT - 201706730 201706730 4481 Upham ST 08/30/2017 EXPIRES: 08/30/2018 Permit for emergency repair: repair sewer line about loft in yard only. INstall Dual sweep clean outs, squege for bedding. (Right of way permit separate) I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am iiie legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date V 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of ChiKBuilding Official Date @ U+V«: REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. td ' City of 16 Or WheatNICILYC COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(cDci.wheatridge.co.us FOR OFFICE USE ONLY I Date: Plan/Permit # "Z -C))-) ��' � -� 3C) Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: q v Property Owner (please print): {- o 6' stz k- Phone�303 )9q9 — 5' M Property Owner Email: Mailing Address: (if different than property address) Address: 4 c'av'e City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Contractor: Pa micc GcCoyelt'roo S0,6i C-eS Contractors City License #: I MU!L Phone: 1c)) -L l6 r q � - S Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL 0 RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT OTHER (Describe) JeWcf (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) t�g� Ely�f�dticy�� Sewc-r lthe (e heti✓ CC�o0 0A pvlU� r V�SA-v<<IJ Sq. FULF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) Z 9 o o0 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLEONE. (OWNER) ONTRACTO or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): DATE:21 c3 ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Ridlelinn Muicinn Vnhinfinn• Ct i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: U Job Address: ❑ No one available for inspection: TimeAM/PM Re -Inspection required: Yes �N r When corrections have been made, call for re-insEy -ion at 303-234-5933 �I Date: / `/ % Inspector: v DO NOT REMOVE, HIS NOTICE Z/ 09/01/2015 14:01 7202495122 JOSH -WARD PAGE 0 BuildingCity of Wfi(�at Division 7500 W 291hA Ridge, N .`i O$a3-237-8929, InsPeCtion303-234-5933 (pleasePrOPOrty Address: Pr*Perty Owner plino:Phone: .+ Con actor } � Y . « 1F . .. '. ."! tf :, • i :ea is « i f : 2M ! i s ;. .. i { i � Y k DEPAkTN&T 06t &&Y, Bldg VOlUa i n: $ • Phone: '7Z-e 7 — 67 Electrical: Plumbing: Mechanical: City License # City License # City License # Squares u's - Gallons (please print): 303 • Phone: '7Z-e 7 — 67 Electrical: Plumbing: Mechanical: City License # City License # City License # Squares u's - Gallons 0 0 9 ~ 3 ~ p 9 ~ 1 ~ A v Z 0 -i m O m ~ 2 N -i q o' m c a ~ m 0 ~ =r ~ C n o m 1 1 m (D CD N (D CY s d~ ~R m p, 3 3 0 dC) CL P " o dC) o ~ ~ M y O a ~ A ~ w O 7 fQ < 0 N .o O ~ N ~ Q ~ <s fC Cl IG ~ ~ p 3 C a ? > ~ ~ m w „ a C ~CL m O w ~ o m ~V 0 ~ D ~ z ~ E; < a _ C) 0 o ~ O S y ~ v v N 7 ~ O N m N ~ N~ ~ * tt) N ~ n~ ~ ~ M Ul 0 a ~ ~ ~ m O N y m ~ m 1D 3 o , f (D N N f0 61 O 7 < a COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 75507 BUILDING INSPECTION LINE -(303-234-5933) Date : 5/12/2003 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: ROBERT FELCHTINGER Property Address : 4481 UPHAM ST Contractor License No. : 21612 Phone : 503-6593 Company : Gas Detection Service Inc. Phone : 738-5938 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify lhat the setback distances proposed by this permit application are accurale, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all condi[ions printed on this application, and lhat I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Rid9e ordinances, for work under lhis permit. (OWN ER)(CONTRACTOR) SIGNED DATE % Description : NEW FURNACE Construction Value : $1,900.00 Permit Fee : $86.13 Plan Review Fee : $0.00 Use Tax : $22.80 Total : ~ $108.93 Use : 10 BUILDING DEPARTMENT USE ONLY Zoning Comments: SIC : Sq. Ft. : Approval: Zoning : Building Comments: Approval : Public,Works Comments: Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : 21612 Company : Company : Company : Gas Detection Service Inc. Expiration Date : Expiration Date : Expiration Date : 5/12/2004 Approval : Approval : Approval : OKIKS (1) This permit was issued in accoNance with the provisions set torih in yopur apptication and is subject to the laws of the State of Colorado and to the Zoning Regulalions and Building Cotle of W heat Ritl9e, Coloretlo or any other aDPlicable orUinances of the Ciry. (2) This permit shall expire if (A) ihe work authorized is not commencad within sixty (60) days (rom issue date or (B) the building authorized is suspended or abandoried for a period o( 120 days. (3) If ihis permit expires, a new permit may be acquiretl for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the naWral9ow o( water causing a drainage problem. (5) Contractor shall nolify the Building Inspector twenly-four (24) hours in advance for all inspections and shall receive written approval on inspection card before pm diing with successive phases of the job. (6` T uanc of rmit or the apProval of drawings and specifcations shall not be constmed to be a Pertnit for. nor an aPProval of, any violation of the x~mv w ilding codes or any other ordinance, law, rule or regulation. ~ 49 Chief Build g Inspector F WHEqr COMMUNITY DEVELOPMENT DEPARTIIENT Building Permit Number: ~ o q BUILDING INSPECTION LINE - 303-234-5933 Date: CITY OF WFIEAT RIDGE V m 7500 WEST 29'I'H AVENLTE WHEAT RIDGE, CO 80215 - (303-235-2855) COL OR A00 ,yHH~F '~5 A91i"~"4~i ~d ~O~a d Property Owner: !Zo b r--"'r N ' Property Address:,/ u df 5-7- Phone : 303- 503- C Contractor License No.: -;7,1( /;7- Company: 6-f15 De-rEcrb~ 56.-~,u.Zv ~ Phone: 303--739-5'778' OWNER/CONTRAC'IOR SIGNATURE OF UNDEASTANDING AND AGREEMENT I hereby certify that the setback distances proposed by [his pemdt applicarion are accurate, and do notviolate applicable ordinances, rulcs orregulations of the Ciry of Wheat Ridge or covenants, easemrnts orrcstrictions of record; that all meazuremenis shown, and allegations made are accunte; [hat I have rcad and agrec to abide by all conditions printed on this application and Ihat I assume full responsibility for compliance with the Whwt Ridge Building Code (U.B.C) and all other applicable Whea[ Aidge Ordinances, for work under [his pemtit (OWNER)(CONTRACTOR):SIGNED DATE DESCRIPTION: NE~ '47CA,Z,1 1- Construcrion Value:$ 1`1oc`% Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ BUII.,DING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: ResidentialUnits: Elechical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expitation Date: Eacpiration Date: Approval: Approval: Approval: (I) This pamit was issued in acco+denu with the provisiom set foNh iv yow applicatlon md is subject m the laws of the Stats oCColondo and m the Zoning Regulatloas aed Bw7mvg Coda o( Whn[ Ridge, Colmado or eny oNa sppliwbl< ormnmca ai the Ciry. (2) This pennit sfiall exyiro if (A) the work aut6orized is oot commmced withm sixry (60) days from issuc dax or (B) the building sutLorized'u surymded or abandoned for a period of 120 days. (3) IftLis perrmt exy'ues, a n<w pe=mit may be acquved for a ke o(one-helf the amowt nomulty ttquired, ymvided no c6mgu hev< bem or will be made iu theoriginai plaas andspecificntions eudany sutyeation orabandonmeuthu not ezceeded one (t) year. Ifchenga Lave bern or itsuspension orabandonmevt aceeds one (1) year, fiill &a sfiall be paid for a new pnmit (4) No work of any vunn<r s6all be done tbat wil1 chang< the vanval flow oCwata caucing a dreinage pmblem. (5) Contractorshallnocfyth<Huildioglnspectorhvmry-fow(20)homsinedvmceforallivspectlonsends6allreceivewriueoapprovaloninspeclioncazdbetore pmceeding with succceave pLasu of the jab. (6) The issuance of a pe}mit or the approval of dnwings end specificadoas shWl uot be covstrucd m M a pemut for, nor an approval of, any violatiou of the pmvisions of the bWlding codo or avy other ard'mance, Uw, iule or ttgulatiaa Chief Building Inspector COMMUNtTY DEVELOPMENT DEPARTMENT Building Permit Number : 15388 BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE Date : 4/24/2003 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner: COLDWELL BANKER Property Address : 4481 UPHAM ST Phone : Contractor License No. : 19650 Company : SLATTERY & CO, Phone : 744-6311 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $1,250.00 I hereby certify that the setback distances proposed by this permit appiication are accurate, and Permit Fee : $62.31 do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations Plan Review Fee : $0.00 made are accurate; that I have read and a9ree to abide by all wnditions printed on this Use Tax : $15 00 application, and that I assume full responsibili c, liance with the Wheat Ridge uildi g . licable r inances, for work under this rmit. Code (U.B.C.) and all other apI~ \ TOt21: $77.31 (OWNER)(CONTRACTOR)SIGftl~ ~ DAT Use: Description : INSTALL 40 GA N LOW BOY DOMESTIC HOT WATER HEATER IN CRAWL SPACE. PER DARIN MORGAN T& P RELIEF CAN BE PIPED TO A DRYWELL W/ ROCK Zoning,Comments; Approval: Zoning : Build,iog Gomments'' Approval : Public Works Commen;tsi' Approval: Occupancy: Walls BUILDING DEPARTMENT USE ONLY Roof : Stories SIC : Sq. Ft. : Residential Units : Electrical License No : Company : Expiration Date : Approval: Plumbing License No :19650 Company :SLATTERY & CO, Expiration Date : 4/24/2004 Approval : OKIKS Mechanical License No Company : Expiration Date : Approval: (1) This permit was issued in accordanca with the provisions set forth in yopur application and is subject to the laws of lhe State o( Colorado and b the Zoning Regulations and Building Code of W heat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days fmm issue date or (B) the building authorized is suspentled or abandonad for a periotl of 120 tlays. (3) If this permit expires, a new pertnit may be acquired for a fee of one-half the amount normatly required, provided no changes have been or will be made in the original plans and specifcations and any suspension or abandonment has not exceeded one (1) yeac I( changes are made or if suspension or abantlonment ezceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the naNral flow of water causing a drainage problem. (5) Contractor shall notify ihe Building Inspector Rventy-four (24) hours in advance for all inspections and shall receive writlen appmval on inspection card be(ore pmceediing with successive phases of the job. (6) The issuance of 20-eii or~the~pp roval of drewings and specifcalions shall not be construed to be a permit for, nor an appmval of, any violation of the provisions uii in/dd~(dany other ordinance, law, rule or regulation. /~~~Chief Building Inspect g of WHEqr CONIMUNITYDEVELOPMENTDEPARTMENT q BUII,DING INSPECTTON LINE - 303-234-5933 ~ c CITY OF WHEAT RIDGE 7500 WEST 29TH AVENiTE ~o o WHEAT RIDGE, CO 80215 -(303-23j5-2F~85~,y1~.~3 C OR AO APP~K TION Property Owner: Building Pemvt Number: Date: PropertyAddress: AV uQUW~sr Contractor License No.: OWNER/CONTRACTOA SIGNATURE OF UND&RSTAIJDING AND AGREEMF,NT I hereby cerdty that the setback distances proposed by this peimit application arc accurate, and do notviolate applicable ordinances, mles orregulauons ofthe City of WheatRidge or covenants, eazements orrestricfions ofrecord; tha[ al] measuremcnts shown, and allegatlons made are accurate; that I have read and agee to abide by al] conditions pnnted on this applicatlon and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C) and all other applicab7e Wheat Ridge Ordinances, for work under this permit (O W NER)(CONTAACiOR): Phone : 1-505 ^ Phone: Construction Value:$ J?S6OB- Permit Fee:$ Plan Review Fee:$ Use Taac:$ TOt31:$ ~.o,-) twkr-&-~ DESCRIPTION: rNsau.. Aez~o d~J~~. BUII.DING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Plumbing License No: Mechadical License No: Company: Company: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) TLis pumit was issued in aaor3ance with the provisions set foltL in your appliceROn aud is subject W Ne ]aws of the Stah of Colomdo nnd to the Zoning Regulations andBw7ding Codes of Wheat Ridgq Colondo or eny otLu epplicaLle ord'mances of the City. (2) 1Lis pvmit shall expve if (A) the work authoriud is not comme¢ced within sixry (60) days from issue date or (B) the bwld'wg authoriud is suvpended or abaudoned for a paiod oF 120 days. (3) Ifthispumitezpires,anewpexmitmaybeacquixedforefeeofone-LelftheamomcnormWlymqu'ved,providednochauguhavebemorwillbemadein theadgimlpians endspeeiScaEOns andany suspension orabandonmentLas aot ezceededoae (1) yeu. Itohanges Lavebeen orifsuspevsion orabandonmmt exueda one (I) yeay fitll feu sLall be paid for a new persuit (4) No wo& of eny mmner eCall be done Poat will chmge the naGUal flow ofwahr causing e d}ainage pmblem. (5) ContrnemzsLell aorifytLeBnildi¢gIupectortwenTy-four(24)howsiuadvancefmall inspeetionsandsLellroceivewrittenapplovil oninspectionenrdLefore pmceeding with successive phases ofthejob. (6) The issuance of a permit or the approval of deawings end speci5catioas shall not be coastrued to be a pexmit for, nor nn approval o( auy violaROn of the pmvisions of the building codw or any othw ordioancq law, rule or zegulation. Chief Building Inspector