HomeMy WebLinkAbout2603-2607 Teller Street` City of Wheat Ridge Residential Roofing PERMIT - 201700947 PERMIT NO: 201700947 ISSUED: 05/30/2017 JOB ADDRESS: 2603 Teller ST EXPIRES: 05/30/2018 JOB DESCRIPTION: Replace roof with asphalt modified bitumen - 35 squares (2603-2607 Teller Street - DUPLEX) *** CONTACTS *** OWNER DE SELM MARVIN L SUB (303)988-1912 Julie Comstock 019468 L. F. Comstock, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: UA / Unassigned 0 *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 14,140.00 FEES Total Valuation 0.00 Use Tax 254.52 Permit Fee 283.55 ** TOTAL ** 538.07 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2-inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer&Crms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. N 1 CTION RECORD INSPECTION ONLINE FORM: http-//www.ci.wheatridge.co-us/inspection �C>�) I , ((C.,,- INSPECTION REQUEST LINE: (303) 234-5933 Occupancy/Type kl� Inspections will not be performed unless this card is posted on the project site. **Penned nn insnection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Rough Inspections Concrete Encased Ground (CEG) Underground/Slab Inspections Foundation / P.E. Letter Initials Do Not hour c;oncreie riw, l v -Ilip o.u, --• • ••-- • --- - - 1% F I IVB r-rr• - -- - Rough Inspections Inspector Comments Underground/Slab Inspections Date Initials Electrical Sewer Service Plumbing Lath / Wall Tie — _ _ -r.r rte_ w�.,..•., Ir�cr�nr+innc Do Not Cover Under rouna or tseliownn-oiaw V.VI 1% F I IVB r-rr• - -- - Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Date Inspector Comments Final inspections Initials Inspections from these entities should be requested Landscaping &Parking /Planning Dept. one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW &Drainage /Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate does not constitute authorization of occupancy. of Occupancy is issued. Approval of the Final Building inspection � ;. ,,,.+;­ oro rrimnlatM from the Fire District and electrical low voltage "For low vonage pernoLa by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Roofing PERMIT - 201700947 PERMIT NO: 201700947 ISSUED: 05/30/2017 JOB ADDRESS: 2603 Teller ST EXPIRES: 05/30/2018 JOB DESCRIPTION: Replace roof with asphalt modified bitumen - 35 squares (2603-2607 Teller Street - DUPLEX) *** CONTACTS *** OWNER DE SELM MARVIN L SUB (303)988-1912 Julie Comstock 019468 L. F. Comstock, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 14,140.00 FEES Total Valuation 0.00 Use Tax 254.52 Permit Fee 283.55 ** TOTAL ** 538.07 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€TMs installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201700947 PERMIT NO: 201700947 ISSUED: 05/30/2017 JOB ADDRESS: 2603 Teller ST EXPIRES: 05/30/2018 JOB DESCRIPTION: Replace roof with asphalt modified bitumen - 35 squares (2603-2607 Teller Street - DUPLEX) I by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the properly and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed and that.all work to be per armed is disclosed in this document and/or its' accompanying approved plans and specifications. Sign, ure of OWNER or CONTRACTOR (Circle one) Date I . 'This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 1 If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a pe all t,b construed to be a permit for, or an approval of, an violation of any provision of any applicable code or a��nce o r f this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of heatide COMMUNITY DrVF-.t.oP,,,ME i Building 8 Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 ' Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: 6'1:31411 Plan/Permit #� Plan Review Fee: Building Permit Application Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. **` Property Address: Owner Property Owner Email: 0 onn f vr'y-1 () a Mailing Address: (if different than property address) Address: City, State, Zip: C7 D� ,a U (-o ArchitectlEnaineer ArchitectlEngineer E-mail: Contractor: LF Phone: Phone G _IC`f Contractors City License #: 7 CrJ c'� Phone: 3 � -- V J Contractor E-mail Address: k' nit C Q e -y-, Stab Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License ## Mechanical: W.R. City License # Complete all information on BOTH sides of this form S'30 v Mi ❑ COMMERCIAL [RESIDENTIAL Description of work:, (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION [RESIDENTIAL ROOFING RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) Lr] RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects„ please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) 1-�-r IV I � Sq. Ft./LF 3s—Btu's Amps Squares Gallons Other Project Value: (/Contract value or the cost of all materials and labor included in the entire project) I ON NEWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record, drat all measurements shown and allegations made are accurate, that I have read and agree to abide by all conditions printed or, this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances fir "pork under any permit issued based on this application: that'l am the legal o%vner or have been authorized by the legal owner of the property to perform the deseribed xvork and aur also authorized by the legal owner of an) entity included on this application to list that entity on this application - CIRCLE 0,NIE - pplication.CIRCLEOr4'E: (Qit'i4ER) (O:*'TRACT ar (AUTHORIZED REPRES'E.N74TIIG) of (01K ER) (CQ: -'TRACTOR) PRItiT NAME: t` 0 f ZC r SIGNATU /7 $"2 DATE: ZONING COMMMENTS. Reviewer BUILDING DEPARTMENT COMMENTS: Reviewer. PUBLIC WORKS COMMENTS: Reviewer PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Receiver! ❑ Not Required Sanitation District ❑ Receiver! ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION SPRINKLERED: OCCUPANT LOAD`. Building Division Valuation: $ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M / 1) Job Address: i166_) To l/ toL 6 f Permit Number:((jl%c70"iy7 I- J ❑ No one available for ins ction: Time AM/PM Re -Inspection required: e No When correct' ns have been made, call for Date: Inspector: q - 2 i CITY OF WHEAT RIDGE %Vr Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax 2z I-- Fr-. INSPECTION NOTICE �F Inspection Type: Job Address: 7 -- Permit Number: �No one available for inspection: Time' AM/PM Re -inspection required: Yes No *When corrections have been made, call for re-inspecdiont, t 303-234-5933 Dat . A Inspector: DO NOT REMOVE THIS NOTICE 1 l�� CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: m 1 o Job Address: 2- Ly ` 1 /%,t 7 Permit Number: 0 / % b r, ':� 1-/ ❑ No one available for inspection: Time d AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date /- Inspector: i i DO NOT REMOVE THIS NOTICE INSPECTION RECORD Occuaancygype °'INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. �nD3 INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS J OB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons •� _ Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof/ French Drain Sewer Service Lines Water Service Lines SIGNED PRIOR TO PROCEEDING Insulation CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) NO CONCRETE nnR IINTII ARnVR HAS ROUGHS Sheathing Lath / Wall tie Mid -Roof •� _ Electrical Service Rough Electric Rough Plumbing Gas Piping Rough Mechanical ABOVE INSPECTIONS TO BE Framing SIGNED PRIOR TO PROCEEDING Insulation - Drywall Screw FINALS " Electrical Plumbing Mechanical Roof �2 Building Final Fire Department - R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER F ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Tvpe- K In� oO r Job Address: - 07 elP py 4, Permit Number: _ ID 'z 4E f(t�C'12 {'Ll 0 7�ai �LX� 7�XA2 (( J ❑ No one available for inspection: Time t { ' M Re- Inspection required: Yes When corrections have been made, call for re - ins ectlon at 303 Date: {('�) Inspector: DO NOT REMOVE THIS NOTICE " ' City of Wheat Ridge - r� Residential Roofing PERMIT 102662 PERMIT NO: 102662 ISSUED: 11/30/2010 JOB ADDRESS: 2603 -07 Teller St EXPIRES: 11/30/2011 DESCRIPTION: Reroof 10 sqs with SA modifiedflat roof tie into 3 tab shing * ** CONTACTS * ** owner 303/279 -4515 Marvin Deselm sub 303/988 -1912 Larry F. Comstock 01 -9468 L. F. Comstock, Inc. * *.PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0592 BLOCK /LOT##: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 3,900.00 FEES Permit Fee 109.20 Total Valuation 00 u Use Tax 70..20 ** TOTAL ** 179.40 j Conditions: 6 nails per shingle is required. Ice dam membrane is required from eave edge to 2' inside exterior walls. Board sheathing with any gap greater than 1/2" requires panel sheathing overlay on entire roof. Sheathing inspection is required prior to covering. Contractor shall provide ladder for inspections. Scheduled inspections that cannot be performed due to inclement weather must be cancelled prior to 8:30 a.m. on the day of inspection or a re- inspection fee will be assessed. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and /� its' accompanying approved plans and specifications. ignature f OWNER or CONTRACTO (Circle one). Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field sp 'on. Signatur o 'ef Building Offical Date INSP_ TION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. il i�t h e II1' i, t'tan # Building 8- Inspection Services Division _- 7500 W. 29 Ave., Wheat Ridge, CO 80033 parn;I, it Office: 303 -235 -2855 k Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application Property Aiid ess: _2 O 3 - Z1, 0 7 Property Owner (please print): M RvI Ad � i SFi M Phone: 303 a 7q° 4 f Z Mailing Address: (if different than property address) Address: City, State, Zip: Confieactas: L . G' Cesm s n �1 � i..s t - - -- contractors City License #: Phone: 3v3- gg -1 ill SJ 0- racfiars; Electrical: Plumbing: Mechanical: City License # City License # City License # C��c71 � it39a3'�FtrNt?C�{3 Contract Value:. (2� 61tzj & 4 .4S, ( Ar+TiO $ -- 3-q OC rN57 5R M°O I/71,66 - 7 le-.A✓70 3-7488 Review Fee (due at time of submittal): Squares _ I v BTU's Gallons Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby . certify that the setback distances proposed by this permit . application are accurate and do not violate applicable ordinances, rules or regulations . of the City. of Wheat Ridge or covenants, easements or restrictions of record;. that all measurements shown and allegations made g are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that l am The legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. - - CIRCLE ONE: (OWN (CO TRACTOR) o (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: 42 -!Zyf rYlg; OG� SIGNATURE: - �/t DATE: C / l DE:P.A''R`fft7lET+fY �rSCIY L / v,,.L / J ✓/ YONING GOTa1ME ` T � r / � m �x r ^^ ci✓.�i/„ it /y , v rev ��l s ✓a e`r'vv1 rUN y ✓ Za�uu9 � s � f4,y ✓� �r �, �G� r-x ^ a � ✓ (.� /�rl A . " a "'� �" � .✓L � .,, l dy r ' /' ,+ . 1 r Y.a � s... /,,. �:/. r ,fir r n �i /r L`g410�j?er� / y i>✓ rr ✓ � t^ � U a'�, ✓ ✓r I <� �k� ri r� � 1 %, ✓ � sr ✓ /l y ?l c✓ r ?✓ f� �✓ ��a�K�r `" r �� /y�Y � rs 3 :/, / l t .. . S CuJ ✓ Ce z �' � ✓ �,3 ' Tt7 �� a 'r ./ ar ,. a S � >.+r"` �' �N - z BUItbINB DEPARTf1��NT/GO.MtJiE1NT.`S'r ./ 3 s ri` >pE/ , r�?�,�F, � �,✓lr s,/,.'�""'''�' �s �C / / y •'; � �2E�0W0F'� l f .? Fyr✓ vz� a � r s� ✓l s h � c/" /rl x! ✓y W���j,3 Er :, , A u / c ?� /L// ' %r ., 7✓ /' ✓' 9 r s /l !:. ay L fi ;, .`�.� -,f `^SC's i'. a ? ✓ /r: >1` y z / r✓"✓ ✓ r ✓�� Via"' /„ .'i `--� .�� C /i r f „ n : z/ �� � rar "F e i ✓ � ✓� / � turf ���'Y �Lf lrt""^» � ���� G : r -u z U rY - s/'�r rr. /.✓u �j�� / �.. i 1 7y��- ^',a / �/1��4 �'' AU6L`I�WORKS CpMAREppTS / y` f '' ✓^''; -'�� � � / �^N ' � g' �,7 r'�� _ �2VdeW6T'Cr :✓t `�- / �r/ e <� ✓ /!a- �r � s ✓" w ? ?. FYRE I)EPARTMEi+�T� }:7 approved W /COJr)nJ @ptS✓ l?31Sap aroYed 'C} ltA 7gYieW T�gShred Bldg Valuation:$ A r -' ._.,.� ` ' `s.u.,w � _ _.,.:. _, 3 a � ✓�,v DEPARTMENT Of GOMMUNITY DEVELOPMENT 7500WEST29thAVENUE BUILDING INSPECTION DIVISION PERMIT N0. M94#19970 234-593° P.O. eOx638 CITY OF WHEAT RIDGE, C0L0. THIS PERMIT VALID ONLY WHEN SiGNED BY THE CHIEF BUILDING INSPECTORANDRECEIPTEDBELOW. APPLICATION FOR MISCELLANEOUS PERMIT t OWNER ~G/o+V /✓z Szm`_ JOBADDRESS T CONTRACTOR - ADDRESS zl~46 /A' ~ ~ ~ d4v c' - ADDFESS "Z~7e-5 { '57 PHONE yvZU - G!U ~ ZIP CODE LIZL5 GTY GZIP CODE CONTRACT PRICE $ X ~~L01 PHONE ~/-3 3 -'fY6O2 ! LICENSE NO. ~ ? 7 7 d DATE 4~ I. TVPE Ground❑ Wall❑ Prolectmp❑ 01hsr SaDPoae 2. MATERIAL Tofel Squme FoN SIGNS 3 ILLUMINATION Yes❑ No❑ T pe Eleef Pamit No . y . . 4 SET BACK FROM PROPERTY IINE N (Speeify wl+ich ia front) _ ❑ S_ E ❑ _ W ❑ ❑ Zont_ ADDrwed,ZOne Inapetlor Disopprwed I, TYPE Solido More Thon BO% ODenO Lou TAan 8 0% Open ? MATERIAL Heipht FENCES 3. SET BACK FROM PROPERTY LINE N (Specify whichietront) _ ❑ 5_ E ❑ _ W ❑ ❑ Zme_ ADDrweA,Zom InsDmcia Diaapproved ~ s,.,4 3 - i Z l-,f 15 - G v~ ~ :OTHER ' 3 Ga 4~0,~ G_ .a . ~ P DRAW SKETCH OFt SH B OW, THE ENCE,SIGN,OR THER STRUCTU , GIVIM1v DI5T4NCES FROM PROPERTV LINES. (SETBALKS OR PROJELTqNS INCLUDED) NOT VAIID SPECIFY NORTN STREET NAME SHOW OISTANCES FROM THE MAIN BUIIDING T6ADJOINING HOUSES, STREETS, AND PROPERTY I.INES;ON IRREGULAR LATS,SHOW l DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 180 DAYS FROM THE DATE OP ISSUANCE IF WORK IS NOT STARTED WITHIN THAT TIME. ELECTRICAL PERMIT STATE LICENSE N0. PLUMBING PERMIT STATE LICENSE N0. MECHANICAL PERMIT ALUMINUM WIRE UNDERSIZE B ILLEGAL FLOOR BSM IST 2ND 3RD 4TH NQ FLEL:CircleQw CwidlPropaM EIeeSola 140. WATER CLASET FORCED AIR - BTU TEMPORARY METER WASH BOWL HOT WATER - BTU NEW SERVICE - AMPS BATM TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTING SINN OTHER HEATING GARBAGE DISP REFRIGERATION S'ISTEM POWER SUB-GFCUITS WATER HEA7ER Refri arant Group UTILI7Y(RANGE,DISPOSER,ETC) AUTO.WASHER Fbunda CAar a FIXTURES DISH WASHER AUTOMATIC SPRINNIEP SYSTEM WIRING MOTORS 9 CONTROLS FI.DOR DRAIN EIEVATOR SIGNS URINAL TRANSFORMERS 9 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES I hsreby acknowledqe that Mis aPOlica- fion u corroct aed underslanC thaf I cannof stort this Droltlct unfil thia oppli- cotion is aDproved. I snall comply wifn fhe lowf ot Ihe Slafe of Colorado and to fhe Zoninp Repulotions ond Bmldina Code ofthe City of Wneai Ridpe. Any vi0lation of the above terms will cause immediote revocation ol fhis permit ~L- - A olie mt 9io^^lur• ~ PERMIT FEE USE TAX TOTAL FEE PROV ~ CHIEF BUILD Date Issued- INSPECTOR,City of 3 - e-ti J -0-6 Ridqe ~ 71(_1 CALL 234-5933 24 HOURS IN ADVANCE FORINSPECTIONS