Loading...
HomeMy WebLinkAbout2744 Teller StreetRoom Schedule Number Name Area Basement 32 FINISHED 806 SF BASEMENT Basement: 1 806 SF Main Level 18 BATH 41 SF 16 BED 71 SF 4 DINING 139 SF 1 FOYER 126 SF 3 GARAGE 544 SF 2 KITCHEN 116 SF 7 LAUNDRY 95SF 6 OFFICE 130 SF 19 STAIR 46 SF Main Level: 9 1309 SF Second Floor 12 CLOSET 77 SF 15 DRESSING AREA 172 SF 10 M. BATH 115 SF 11 M. BED 130 SF 9 W.C. 20 SF Second Floor: 5 513 SF Bathror space n Alarms MINIMUM CLEARANCE FOR TOILET, BATH, SHOWER SPACES TO COMPLY WITH R307: TOILETS 30" CLEAR AREA WITH 15" ON CENTER SIDE TO SIDE. **See G003 for structural. SHEET NOTES 4 Azo1 210 4X4 POST TO SUPPORT OPENING IN ATTIC ABOVE AND CEILING JOIST FRAMING; NEW FOOTING IN BASEMENT POURED ON SLAB UNDER FRAMED FLOOR; CONCRETE FOOTING SHALL BE 12"X12"X6" W/ (2)tf3 EACH WAY LOCATED AT 2" CLEAR OF BOTTOM. 213 PROVIDE (2) ACCESS PANELS TO STORAGE 3' TALL BY T WIDE; EXISTING KICKERS TO REMAIN. 214 SKYLIGHT ABOVE BETWEEN THE EXISTING JOISTS; DETAILING PER MANUF. SPEC. 215 INSULATE EXISTING WALLS WITH R-20 INSULATION AND ROOF WITH R-49 INSULATION. 217 NEW HEADER; RE: CALCS. 218 INSULATE STAIR LID WITH R-49 AND WALLS WITH R-30. 219 2 -SIDED FIREPLACE; THIN BRICK FINISH; OWNER SELECT INSERT AND FINISH. 230 NEW 4X4 POST IN WALL 235 (N) SHOWER WITH GLASS ENCLOSURE; OWNER SELECT TILE FINISH AND FIXTURES. 236 (N) SINKS AND COUNTER TOP WITH BASE CABINETS BELOW; OWNER SELECT FIXTURES AND FINISHES. 237 (N) WATER CLOSET; OWNER SELECT. 238 (N) FREESTANDING TUB; POSITION TO BE UNDER SKYLIGHT AS SHOWN. 239 (E) CHIMNEY TO REMAIN. OR NEW FUEL GAS APPLIANCES, PLEASE PROVIDE TO THE VSPECTOR AT THE TIME OF ROUGH INSPECTION AN 30METRIC FUEL GAS PIPING DIAGRAM. THE FUEL PIPING IIAGRAM SHALL INCLUDE THE EXISTING FUEL GAS PIPING iS WELL AS THE NEW FUEL GAS PIPING. THE ;ALCULATIONS SHALL BE FOR THE COMPLETE FUEL GAS SYSTEM PER CODE SECTION G2413. BUILDING FLOOR PLAN NOTES A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS MECHANICAL HVAC TO EXTEND THE EXISTING SYSTEM AND NOTIFY OWNER CONSTRUCTION MANAGER OF L ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL E _ 7 DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES POINT. J_NZ B. MECHANICAL HVAC TO EXTEND THE EXISTING SYSTEM C Q UNDER THE FLOOR OF THE ATTIC FINISH. E _ 7 C. VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES J_NZ MEET OWNER AND/OR LOCAL CODE REQUIREMENTS. O D. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS U SHOWN OR NOTED OTHERWISE. \( E. NON -LOAD BEARING WALLS ARE NOT ALLOWED TO aQ 001p h' Owwx>iO INTRODUCE LOAD UNLESS INDICATED ON STRUCTRUAL wa cls,w PLANS. F. NON -LOAD BEARING PARTRIONS TO FLOAT 1-1/2' MIN. �¢ Q ABOVE SLAB -ON -GRADE CONDITIONS. mm G. OWNER SELECT ALL FURNITURE, FIXTURES, AND 1 EQUIPMENT. H. GENERAL CONTRACTOR TO INSTALL TILE AND BASE. GENERAL CONTRACTOR TO SUPPLY AND INSTALL MORTAR, ADHESIVE, AND GROUT. GENERAL CONTRACTOR TO INSPECT ALL TILES AND REJECT DAMAGED OR SUBSTANDARD TILES PRIOR TO INSTALLATION. J. ALL FLOORING AND BASE MATERIAL TO BE INSTALLED ACCORDING TO SPECIFICATIONS. WALL TYPES LEGEND: _ EXISTING TO REMAIN Q NEWWALLORINFILL E _ 7 EXISTING TO BE REM, n a Z0 ``2^) V z J J_NZ O w U oiwmo o z w O �U aQ 001p h' Owwx>iO wa cls,w J J � D �¢ Q a= �3 mm 8w;E6 n a ``2^) V z LL U_ w a 0 w� z w O �U J H 1n W wa cls,w J J � D �¢ a= �3 U n a w O w Z m pEf U O Z G U O r Z w g M1 a 7 a p JOB NUMBER: 21009 DRAWN BY: SLS APPROVED BY: SLS DATE: 20AUG21 OMpYW draalp is 22'a d0" I Seek eMNes wssss by xieauess SHEET TITLE: SECOND FLOOR PLAN SHEET' A102 C111umWmwOoxLLHeuIl6lmc FMiMI CNOBRIOW-uplmmoniotM iOW -LeplsiMle FAIN-2021unm LIME STPMY. N([OIIBMSI GM INSPECTION RECORD Inspection online form: http://www.cl.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day PERMADDRESS:JOB CODE: Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground 2=4- ri &A4- om-'ek Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 2=4- ri &A4- om-'ek 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS PERMIT/ � ADDRESS: Te JOB CODE: Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 401 Gasline 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof %2 l 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 'For fire inspections please contact the Fire District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** [4�17:Zoning Final Inspection*Protection 18 Building Finai inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. A i CITY OF WHEAT RIDGE _1�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: V— r -'nut lIc;p Job Address: 2 7qf Tf1 er El Permit Number: 2o1704 P 7 F-1tvil R004) ❑ No one available for inspection: Time ;3 7 AM& Re -Inspection required: Yes oNo When corrections have been made, call for re -inspection at 303-234-5933 Date: qI Ll `-)I Inspector: ba/'C L04-77 DO NOT REMOVE THIS NOTICE r City of Wheat Ridge Residential Roofing PERMIT - 201704617 PERMIT NO: 201704617 ISSUED: 07/21/2017 JOB ADDRESS: 2744 Teller ST EXPIRES: 07/21/2018 JOB DESCRIPTION: Residential Re -roof to install Architectural asphalt shingles with ROOF DECKING - 25 sq. *** CONTACTS *** OWNER (303)910-9072 CUPLIN LINDA SUB (720)726-6775 Nicholas Welle 090129 Colorado Continental Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, USE: WHEAT BLOCK/LOT#: UA / Unassigned 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,874.00 FEES0.00 Total Valuation Use Tax 207.35 Permit Fee 204.30 ** TOTAL ** 411.65 (. *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. A City of Wheat Ridge r Residential Roofing PERMIT - 201704617 PERMIT NO: 201704617 ISSUED: 07/21/2017 JOB ADDRESS: 2744 Teller ST EXPIRES: 07/21/2018 JOB DESCRIPTION: Residential Re -roof to install Architectural asphalt shingles with ROOF DECKING - 25 sq. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to c performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRAC�f _ i le one) Date 1. This permit was issued based on the information provided in the permit application and accompanying Flans and specifications and is subject to the compliance with those documents, and all a licabl p pp a statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicab orr Lanny oorrdina r re uloati n of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. (720) 726-6775 ustomer Name CQ 1 Date: Jobsite Address: 72-ixLq Insurance Carrier: QaLL�Insurance Claim #: _ Phone #:3 -)-Z-_ [Q- q0 :3 2- CO Continental Roofing Rep: _ Customer Email: Roofing cSppecifications Tear Off: �9 1 Layer 712 Layer ❑ Other Underlayment: ❑ 15# 7130# q Synthetic Shingle Manufaacttuurer: a_�., Shingle Type. SCT,, Shingle Color: "e H/O: Roof Vent Type: L.36 Box ❑ Ridge ❑ Power ❑ Turbine Plumbing Stacks: 13n1 ❑ Lead ❑ Other Ice & Water Shield Per Code Valley: ❑ Ice & Water Shield ❑ W Pan Hip & Ridge: ❑ Standard ❑ Enhanced Metal Edge: ❑ To Match Existing ❑ Other Roof Decking: ❑ CDX ❑ OSB ❑ Other Attic Inspection: ❑ Yes ❑ No *Nailing Pattern to Meet or Exceed Manufacturer Specifications Insurance Coverage Provided By. Allen Buchholz Insurance P.O. Box 4227 Olathe, KS 66063-4227 913-390-9011 Siding ❑ Aluminum ❑ Vinyl Size: ❑ Dutch Lap ❑ Straight Brand: Fascia: Color: Soffit: Tyvek: ❑ Yes ❑ No Insulation: ❑ Yes ❑ No NON NAILABLE SURFACE CLAUSE: Please note that any defective roof deck/plywood found during tear off of the existing roof covering must be replaced per state building code. Most insurance carriers do not cover this cost as part of your claim. Customer will be respsonsible for this cost at $50 per sheet which includes labor and materials. Customer Initial Special Instructions IX Clean All Gutters of Roof Debris a X Protect All Landscaping X Furnish Building Permit4;9P\ _y) X Cleanup Daily 151 rL��1 XJRoll Magnet Through Yard 5 Yr Workmanship Warranty Provided Upon Final Payment Approximate Start Date: Approximate Finish Date: Gutters/ Downspouts 5" ❑ 6" Gutter Color: ❑ 2x3" ❑ 3x4" Downspout Color: Additional otes -f-a-f-a Lls c. v,i Payment BrAllkdown Insurance Claim Amount Supplement Amount (if needed) Homeowner Upgrade Amount O&P for Complexity of Multiple Trades -I Total Cost (tax included) Terms: This agreement is contingent upon insurance company approval and agreed price. This agreement does not obligate the customer or Colorado Continental Roofing & Solar in any way unless it is approved by customer's insurance and accepted by Colorado Continental Roofing & Solar. Customer's signature below signifies acceptance of all terms and conditions of this Agreement, including all terms on the reverse side hereof. Colorado Continental Roofing & Solar will seek approval from insurance company for any necessary supplements outside of the original scope of work. Customer's `out of pocket expense is not to exceed deductible and any upgrades. Payment due upon completion of each trade. 3 -1 Customer Signature Date C.C.R.S. Rep Signature Date RIGHT OF CANCELLATION PURSUANT TO FEDERAL REGULATION AND COL. REV. STAT. § 5-3-403: YOU, THE BUYER, MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION. RIGHT OF CANCELLATION PURSUANT TO COL. REV. ST. § 6-22-104: YOU, THE BUYER, MAY CANCEL THIS AGREEMENT AT ANY TIME WITHIN 72 HOURS AFTER YOU HAVE BEEN NOTIFIED THAT YOUR INSURER HAS DENIED YOUR CLAIM TO PAY FOR THE GOODS AND SERVICES TO BE PROVIDED UNDER THIS AGREEMENT. Company shall hold in trust any payment from Customer until Company has delivered the materials to your property or has performed a majority of the work on the property. CO 01.15 ADDITIONAL TERMS AND CONDITIONS 1. Approval / General Contractor. This Agreement is subject to the credit and pricing approval of the management of Company. Customer acknowledges that Company is a general contractor and as such will be entitled to 10% overhead and 10% profit, as allowed by Customer's insurance company and state standards. 2. Agreed Price. The full amount of all monies as specified by the Agreed Price, does not include any extras such as carpentry repairs or any other repairs not specked in this Agreement or not covered by the Agreed Price that are necessary to complete the repair or replacement process as required by local building codes or to cosmetically satisfy Customer. 3. Materials. All materials provided by Company will be standard stock materials, unless otherwise specified, and will match existing materials within reasonable tolerance as to color, texture, design, etc. Notwithstanding the foregoing, other products and materials may be substituted for equivalent products due to availability. Customer understands that there is a 2 -day minimum charge for all drying, water extraction and dehumidification equipment provided by Company. All excess materials remain the property of Company. 4. Access to Property. The prices and terms of Company's estimate and this Agreement are based upon completion of the work during normal working hours, and Customer agrees to provide Company access to Customer's property as required for completion of the work. Customer will be responsible if any interruption of Company's work results from Customer's failure to provide reasonable access or due to the acts or negligence of others not under Company's direction. Company shall not be responsible for damages arising from delay due to inclement weather, strikes, fires, accidents, delays in shipments or delivery of materials, or any causes beyond Company's reasonable control. Customer agrees that Cu'stomer's telephone, electricity and water will be made available to Company's personnel during the course of the work. Customer will also furnish at its expense, single phase, 220 -volt, 50 -amp electrical service. Company shall not be responsible for protection of Customer's property, except to provide that protection which is specifically called for under the specifications provided by this Agreement. Customer also agrees to remove, store and/or protect personal property during Company's work. Customer will manage and be responsible for protection of vehicles and property exposed to damage by Company's work. 5. Job Completion. Job completion shall be the date on which Company's work is substantially finished (as distinguished from the date of Customer's acceptance thereof) or the date of Company's last item of work at the property, whichever is earlier. Customer's failure to make prompt payment shall entitle Company, on forty-eight hours (48) hours' written notice, to stop work. The Agreed Price shall be increased by Company's reasonable costs to stop the project and/or resume work. In the event Customer chooses not to pay for a part of the work, an individual line item, or a trade, Customer releases Company of its obligations for the performance of that component with regard to the integrity of the building system as a whole. 6. Insurance / Mortgage Company. Customer hereby authorizes its insurance and/or mortgage company listed on the front of this Agreement to pay Company directly for all work and materials provided by Company to accomplish Customer's replacement or repair. Customer further directs its insurer and/or mortgagee to include Company as a payee on all checks or drafts now or hereafter payable for such loss. Company reserves the right to supplement Customer's insurance and/or mortgage company for increases in the scope of work and/or documented price increases. Customer agrees to allow these supplements to be paid directly to Company. Company makes no representations or warranties regarding Customer's insurance coverage or if Customer's insurer will pay for all or any of the work to be performed by Company under this Agreement. Customer agrees to pay Company in full for all work performed by Company under this Agreement, regardless of Customer's insurance coverage. Customer also agrees to pay Company directly for all amounts, despite depreciation or deductibles, and to also pay for additional work not covered by Customer's insurer and that said amounts must be paid before job completion. In the event Customer breaches this Agreement, Customer agrees to pay Company: a) in full, on a time and materials basis, for all work and materials provided by Company as of the date of such breach; and b) a consulting and adjusting fee equal to 20% of the total cost of the work and materials provided by Company as of the date of such breach, which fee represents the industry standard for reasonable profit and overhead generally paid by the insurance industry and is not a penalty. 7. Limited Warranty. A written limited warranty may be offered on workmanship and materials provided pursuant to this Agreement on the terms and conditions reflected in any written limited warranty materials provided at the time of sale. If Company is not paid in full in accordance with this Agreement, all such warranties are null and void. 8. Past Due Amounts. Customer agrees to pay a service charge of 8% per annum on all balances 30 days or more past due. Customer also agrees to pay for all collection costs, including employee time and expense and all attomeys' fees and costs Company incurs in either collection of and/or protection of its interests in Customer's past due account or performance of this Agreement. 9. Hazardous Materials. Nothing contained in this Agreement shall be construed to require Company to determine the presence or absence of any hazardous materials or asbestos -containing materials affecting the property or to require Company to remove or protect such materials. In the event that Company learns of the presence of such materials on Customer's property, Company reserves the right to immediately stop work and negotiate a change order for such additional work as may be required. 10. Liability. Company is not responsible for damage or loss caused in whole or in part by: the acts or omissions of other parties, trades or contractors; lightening, gale force winds (+50 m.p.h.), hailstorms, ice damage, ice damns (caused by thawing and freezing of ice, water or snow) hurricanes, tornados, floods, earthquakes or other unusual phenomena of the elements; structural settlement; failure, movement, cracking or excess deflection of the roof deck; defects or failure of materials used as a roof substrate over which Company's roofing material is applied; faulty condition of parapet walls, copings, chimneys, skylights, vents, supports or other parts of the building; vapor condensation beneath the roof; penetrations for pitch boxes; erosion, cracking and porosity of mortar and brick; dry rot; stoppage of roof drains and gutters; penetration of the roof from beneath by rising fasteners of any type; inadequate drainage, slope or other conditions beyond the control of Company which cause ponding or standing water; termites or other insects; rodents or other animals; fire; or harmful chemicals, oils, acids and the like that come into contact with Customer's roof and cause a leak or otherwise damage Customer's roof. If Customer's roof fails to maintain a watertight condition because of damage by reason of any of the foregoing, any applicable written limited warranty shall immediately become null and void for the balance of its term. Company accepts no liability to indemnify or hold Customer harmless for claims or damages to persons or property, except to the extent that such damage occurs during performance of Company's work and are the direct result of Company's error or omission. Notwithstanding the foregoing, Company shall not be responsible for damages to any area of the property upon which Company's work has not been completed nor is Company responsible for slight scratching or denting of gutters, oil droplets in driveways, hairline fractures in concrete, damage to flowers or landscaping, or minor broken branches on trees, plants or shrubbery. In no event shall Company be responsible for any type of damage resulting from vibrations, including, but not limited to, interior drywall damage, nail pops or disconnection of chimneys, flues, air ducts, ventilation shafts, exhaust vents, furnace vents or sewer vents. Customer understands and agrees that Company shall have no responsibility for damages of any kind to persons or property occurring after job completion. 11. Hold Harmless. Customer agrees to hold Company harmless in connection with the work described herein and that Customer's maximum recourse shall be, and Company's maximum liability under this Agreement shall be limited to, the amount Company billed to Customer. Customer understands and acknowledges that Company does not warrant or guarantee previous workmanship or pre-existing materials, nor any materials or labor not originally provided by Company. Company shall not be responsible for latent defects in materials and accessories supplied. Company shall not be responsible for rework required as a result of the acts or errors of others. 12. Liens. Should default be made in payment of this Agreement, a lien will be placed on the property and charges will be added from the date of substantial completion at the maximum rate allowed by law. If placed in the hands of an attorney for collection, Customer will pay all attorney and legal fees. PRE -LIEN NOTICE: COMPANY HEREBY PROVIDES NOTIFICATION THAT ANY PERSON OR COMPANY SUPPLYING LABOR OR MATERIAL FOR THIS IMPROVEMENT TO YOUR PROPERTY MAY FILE A LIEN AGAINST YOUR PROPERTY IF THAT PERSON OR COMPANY IS NOT PAID FOR THE CONTRIBUTIONS. 13. Insurance Deductible. If Customer plans to use the proceeds of an insurance policy to pay for any of the work under this Agreement, Company shall not pay, waive, rebate or promise to pay, waive or rebate all or part of any insurance deductible applicable to the insurance claim for payment for the work under this Agreement. 14. Entire Agreement. This Agreement constitutes the entire agreement and understanding of Company and Customer relating to all of the subject matter hereof, and supersedes all prior agreements, arrangements and understandings, written or oral between the parties concerning such subject matter. ANY REPRESENTATION, STATEMENTS, OR OTHER COMMUNICATIONS NOT WRITTEN IN THIS AGREEMENT, OR MADE IN WRITING PURSUANT THERETO, ARE AGREED TO BE INVALID AND NOT RELIED ON BY EITHER PARTY AND DO NOT SURVIVE THE EXECUTION OF THIS AGREEMENT. 15. Ar6ndment. If this Agreement is not cancelled by Customer within three (3) business days after the date of this Agreement, or within seventy-two (72) hours after Customer receives notice from his/her insurer that a claim for work under this Agreement has been denied in whole or in part, if applicable, this Agreement cannot be canceled or amended without written mutual agreement of both parties. 16. Reformation / Severability. Company and Customer intend and agree that if a court of competent jurisdiction determines that the scope of any provision of this Agreement is too broad to be enforced as written, the court should reform such provision(s) to such narrower scope as it determines to be enforceable. Company and Customer further agree that if any provision of this Agreement is determined to be unenforceable for any reason, and such provision cannot be reformed by the court as anticipated above, such provision shall be deemed separate and severable and the unenforceability of any such provision shall not invalidate or render unenforceable any of the remaining provisions hereof. THE TERMS ON THE REVERSE SIDE HEREOF ARE SPECIFICALLY AGREED TO AND INCORPORATED HEREIN. Accepted by Owner Date Colorado Continental Roofing & Solar 1562 S. Parker Rd. #332 Denver, CO 80231 720-726-6775 CO 01.15 Dan Schultz L)o 1-2M 6 1 ? From: no -reply@ ci.wheatridge.co.us Sent: Thursday, July 13, 2017 4:49 AM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Danny Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? / How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address 2744 Teller St Linda Cuplin 303-910-9072 lindacuplin@hotmail.com As, �([. �s­ Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Colorado Continental 090129 3034835661 Contractor Email Address gsjones93@comcast.net Retype Contractor Email gsjones93@comcast.net Address DESCRIPTION OF WORK Are you re -decking the Yes roof? Description of Roofing architectural Material Select Type of Material If "Other" is selected above, describe here: How many squares of the material selected above? Does any portion of the property include a flat roof? Asphalt Field not completed. 25 No-�'/ If yes, how many squares Field not completed. on the flat roof? / TOTAL SQUARES of all 25 V roofing material for this project Provide additional detail re -roof house. 8:12 pitch roof, so it is fairly steep here on the description of z work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 9874.00 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Greg Jones Email not displaying correctly? View it in your browser. 3 i CITYbF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE ❑ No one available for inspection: Time �' 4� �- " AM/PM Re -Inspection required: Yes No" When corrections have been made, call for re -inspection -at 303-234-5933 Z Date: Inspector: „ ra DO NOT REMOVE MIS NOTICE . 1~~~ . . , . . t3EP RTMENT OF PLANNING AND DEVELOPMENT Buiiding Permit Number : 5540 UiLDIN6INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7/28/97 7500 WEST 29TH AVENUE WHEAT'RIDGE, CO' 80215 Property Owner : Property Address : 2744 TELLER ST Phone : 202-0437 ( E t t e 't Gonfractor License No. : 17959 Company : Roto Rooter Service Co. DR SIGNATURE OF UND6RSTANDING AND AGREEMENT elback dlsfancee proposed by thispertnk applicatbn are axurate, 9bb ordinences, rubs or regulations of the CNy of Wheet Ridge or r restridbns af recard; that aU measurements shown,and allagatbns I have raad. anday ree toabide by all coaditions~printed on this sume fullrespons. ibN'dy for complianee witN the Wheat Ridge Building br aonlicatife Wheat Ridae ordiqences, for work undarthis pDrmk._ .':(OWNER)(CONTRACTOR) Description INSTALL OU7SIDE CLEANOUT ON SEWER LINE Phone : 573 0300 ConsUucBon Valu6: $350.00 Permit Fee ; $22.00 Plan Review Fee $0.00 Use Tax : $420 Tota(:' ' $26.20 BUILDING DEPARTMENT USE ONLY Approval : Zoning : Rpproval : Approval: Occuoancv : Walls ~ SIC : Sq: Ft. : Roof : Stories : Residential Units : o~~u..6;..... I L.n..en Nn • cicvu n.01 ~n.c' wv ..v . Company : Expiratiqn Date : Approval : . (t) . nhts aermtt wae Iasuea. Repuktlons antl HtilWin (Z) n i d. red fa' a p . abe (3) If Ws pertMt ezpirea, a i original Plans antl speG ezceeas ona (t) Yeer, h (41 NOworkMBrv/mennat (5) Conllscbr shHk twtNy tl IngwNh euacee (8) Iseuent@ tit a Portn ot the bt dirq codes or Company : Expiration Date : Approval: 0 Mor.hanirall irnnsA Company : Expiretion Date : Approval : 0 - aom sM rorm m rawr appncaaon ena is suna a the Wew, a me sma a cowfado ,nd m me zw,ins xatlo w eiry oMer applicabfe orAineneea of ths Ctty. wt canmenced wMm abcty (80) Eaya hom issue tlate w(B) the bullding auMOftatl is auapentled or for B tee of one-haif the emouM mrmely requlred, provitletl no chengoa have bsen wwNl ba made in the eabwConment has not ezceeded one (t) yaer. H chenpes are matle w M w9ppnebn m ebarWOnment e Me naturol flow Mwster causinB a Meuiapa pmblem. fouf (24) hows in advence for ad inspeclbns a(M ehetl recelve wrilten epprwel oninspectlon ceN betore i antl speclMCatlons ahan not be conswed ro be a penMt for, fror an approval M, atry vbkitlan ottlie Pmvistone le or reBUlatbn. . . Chief uidingInspector T PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BU4LDING INSPECTOR AND MAYOR CALL: 234-5833 24 HOURS PRIOR TO 1NSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 " CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : 3-ft n / r ljj`~-~~ ck e/' Property Address : ol 7I/ 'y Te 11-e r S?~- Phone : ~?OR' O`l3 7 Contractor License No. 7`75 9 yO2 /-/a;l 5 CompanY : 90 f ei -400f4 r 5.2rv,'ct Co Phone : a 4 S-OS~OC~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Conswction value : 3 SO • a a I hereby certiry that the setback distances proposed by this permit appliwtion are accurate, PBftTtit F82 : and do not violate applicable ordinances, rules or regulationsof the Ciry otVJheat Ridge or covenants, easements or restrictions of rewrd; Ihat allmeasurements shown, and allegations . Plan Review Fee: _ made are -accurate; that I have read and agree to abideby all eondRions printed on this appliwlion, and that I assume tull responsibility for compliance with the Wheat Ridge Building Use Tax : Code (U.B.C.) and all other applicable Wheat Ridge ordi nces, (or work under this pertnit. -V2R/9'7 Total: (OWNERxCONTRACTOR) Description : 2.' q'~q Z_i3hin ~Cb'~ts~ Approval: Zoning : Balfd n( g'.CO"~nfHi Approval P.Qt3IiG7VY8Tft5~C- Approval: Occupancy : Walls O cc /'S % GY -P . C~-2 Q✓~ O uf 0 h,$ 41 2 G^ BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiretion Date : Expiration Date : Expiration Date : Approval: Approval: Approval: I% IFPI3W--ffIIiPBZIW Ig ILP,I3S9!RS4t7TMM n ffaTfS~m (1) 7Tis pertnit was luued in acooNance with Uro provisiona ut IoM in yoput spplialian and la suD~'cU lo the iaws of Ne SUte of Cob~aOO anE to Ne Zoning Requlatw~a an0 Builtling CoOe of Wheal RiE9e, Cdoratlo w any other aDO~~ ~inaMes of the Ciry. Tnis permit snail e.Pire il (A) Ne work autMnzed is nol commenud wiUin sixry (60) Eays /rom iuue Eate a(B) the MriWirp auNOrizeG is suspeiWed a aEanaoneE for a perio0 of 120 aays. 11 this permil exprcs, a new pemut may Ee acpuired fa a lee o( ontrfull the amount rwrtnaly required, proviAeG no U+anq" have been w will be maEe in Ihe original plans anC specificalions anE any suspensbn or abaiMOnmenl lws nol ezceeEeC me (1) year. If chanqes are made a d zuspenabn w aEanEOnmenl e:ceeEe one (t) year, lull (ees shali be paiC kr a new pertnil. S<) No work of any rtunner shall be Oane thal will Nange Ne nalural Ilow of water nusiny a dninage Oro01em. 5) Ca+indor sAall noGry the BuilOi~p Insw Nrenry-lour (24) taun in aEvaxe for all inspections anA shall receive writlen apprwal on inspec6on wrA Defae prpceediing wiN suttesSivB phases o lheI'00. (fi) iTa isswnce M a pe(mit Or Ue aDOmvaI of drawings aiW spedfiwtions stwA nol0e wnsWeO W Ee a pertnit lor, nor an apPmval W, any hdation of the provisions of Ihe WiIEInq coAef or any other oNinance. Ww, rule or requlaUOn. Chief Building Inspector For Mayor -THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION , e dr:?M1^io-^.atneu+~. °~M~„`'iTn'Pi~~~•`:,..,, . ~~.'`~'1R , v .'~*F%~' ~*~Y~~'}$iYx4~4'x.,~' .,a,r?f,",'a•.k "x,'Ai"r.+;.. tlrr . t ;g.~ ~ . N~~.'3~ gy'~~ . . JDEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 6931 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 4/23/98 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : Property Address : 2744 Teller Street Contractor License No. : 17590 Phone : 202-0437 Company : C J Roofing Co. Phone : 394-2802 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances propoeed by this pertnit application are accurate, and do not violate appliwble ordinances, rules or regulations of the Cky of Wheat Ridge or covenants, easaments or restrictions of record; that all measurements shown, and allegations made are accurate; that 1 have read and aqree to abide by all conditions printed on this application, and that I assume full reaponsibility for comPliance with the Wheat Ridge Buiiding Code (U.B.C.) and all othar applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTR4CTOR) SIGNED DATE Construction Value : $2,373.00 Permit Fee : $63.00 Plan Review Fee : $0.00 Use Tax : $35.60 Total: $98.59 Use: Description : Layover 1& 2 layers of existing with 3 tab shingles. 10/12 & 7l12 Electrical License No : Company : Expiretion Date : Approval: Piumbing License No : Company: Expiration Date : Approval : Mechanical license No : Company : Expiration Date : Approval: (1) Thia permR was issued in aceorUance with the provisions set foM in yopur applicatlon and is subiect M tlie laws of the State of Coloretlo and M the Zoning Regulations antl Bulltlin~ Code of Wheat Ridge, Coloredo or any other applicable ordinances W the City. (2) Thls pe~mit shall expire d(A) the vrork aut~onzed is rwt commence0 wtthin sUQy (80) tlays hom issue tlate a(B) the building authaized is suspendetl or ebantloned Mr a period of 120 days. (3) tt this pertnR ezpires, a new permtt may Ee acquired for a fee of one-half the amount namally required, pro~rided no changea have been or will be meAe In Me originel plans and specrtiwtions and any suspension or abandonment has not excee0etl one (1) year. If changes are matle a if suspension w abandonment exceetla bne (i) yeer, full feea shaN be paid Tor e new pertnit. (4) No work ot any manner shall be done Nat will change Me natural Bow of weler causing a tlreinape problem. (5) Contractor ahall notlry Ne Buildinp Inapector twenry-rour (2a) hours in advance for all Inspectlons and shall recelve written appiovat on inspactlon cerd before proceediing with auccassiveph asea of the1'ob. (e The ieauance of a permit or the approvel of drewings and spacficatlons ahall not be construed ro be a pertnR for, nor an approval of, any WolaOon of the pmvisions of Me bulWinp cotles w any other ordinance, lew, rule or repulabaa . 4 Chief Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRiOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Properryowner: ;0 0 lloV\ A e~r Property Address : a-7 L/ T1 ( Ie ✓ sf Phone :?0a - O'/ 3`7 Contrector License No. `7 :7 9~.7 Company: GS Phone: OWNER/CONTR,4CTOR SIGNATURE OF UNOERSTANDING AND AGREEMENT ConsVuction Value -Y7 3 e I hereby certiry that the setbacc distances proposed by this permil application are accurate, and do not violate applicable ordinances, rules or regulations of the Cily o( Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and ayree lo abide by all conditions prinled on this application, and that I assume full responsibil'Ry for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Fiidge ordiparWes, fcKwork under this pertnil. (OWNER)(CONTRACTOR) SIGNED DATE -o)~)J~ USE Description L0.youe.- l<~1L4y1e.~- ~ a L°ye'' o exs~St'•wcl JIn~NG`CS ~-~4L Approval : Zoning : Approval: e~trcgvicot,KMqmmentsm Approval: Occupancy : Walls Electrical License No : Company : Expiration Date : Approvai: BUILDING DEPARTMENT USE ONLY SIC Permit Fee : Use Tax : Total $0.00 Sq. FL : Roof : Stories : Residential Units : Plumbing License No : Mechanical License No : Company : Company : Expiration Date : Expiration Date : Approval: Approval: (1) This pertnil waa IaueC In accordante wNh the provisions sN IoM in yopur appliration anE ia subieq to the laws ol the Stale W CobraOO and to the Zonirg RegulaUans anC BuiWiny CoOe of YVheat RiEge, Cdorado or a~ry otner applKade adinances of the Cily. (2) mu Pertrvl slup uMre rt(A) Ihe work aWwnzeE is nol wmrtienced wiNin sixly (60) aaYS from Issue Cate a(8) ft a+iWinp auNMZeC b suspen0ed u a0andoned lu a peAOd o! 720 tlays. (J) I/ Uhis pertril acpiref, a Mw pemut may be acquired Iw a lee W onctuH Uw artaunt normaly requirtd, provided no chanqes Iwve been a wifl be made in the original plans and spedfitatbns and eny suspension w abanCOnment Iws rwt ezceeded one (7 ) year. II Uarpes are rtude or if suspmaion a sWnOOnmanl eaceeCS one (1) year, NI: (ees shall be paiE lor a new pertnit. (4) No vrork al airy rtunner shall ba Aone Nal will change the naturai Mw of water ousinq a dninage problem. (5) Canvaaor snail notly the BuiWlnq inscecta nvenry-lour (z<) taurs in aCvance t« aii inspectiom an0 snan rereive written aDProval on Inspection ar7 Defora proceeEiiiq wiUM successlve ohaxs o! Ne bE (8) Tl~e issuance o1 a pertnit a tlw approval o/Erawings enE specifiptians slwll ral De consUUeE W be a permil lor, nor an approval ol, airy NdaUOn oi tha provisWna o11Ae buiWinp cades or a(ry oMer ortlinance, law, mle or requW4on. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION