HomeMy WebLinkAbout4580 Teller StreetCity of Wheat Ridge E -Res. Window Replacement PERMIT - 201902276 PERMIT NO: 201902276 ISSUED: 10/28/2019 JOB ADDRESS: 4580 Teller St EXPIRES: 10/27/2020 JOB DESCRIPTION: Replacing 6 windows in bedroom and bathroom. U -factor is .28. *** CONTACTS *** OWNER (303)425-5117 BABCOCK FAMILY TRUST SUB (303)375-0745 PAUL BONOW 020146 CHAMPION WINDOWS OF DENVER *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: R-3 / Residential SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,128.00 FEES Window Replacement 50.00 Total Valuation 0.00 Use Tax 86.69 ** TOTAL ** 136.69 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as partes to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Oficial and may be subject to a fee equal to one-half of the original_permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or gran mg of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any aP1 kicrible code or a41ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Gd #Wheat Ry9 10/201239 07:10 ESA Replacing 6 windows e+RgS AMOUNT e2 4580 Teller y 136.4 +R±ggl m= 20190236 PAYMENT »RI+§ AMOUNT 9 Z Sp 136.9 Aq CODE: 66023136 TGR 20&9 - o„aK.mo From: no-reply@ci.wheatridge.co.us Sent: Friday, October 25, 2019 3:31 PM To: CommDev Permits Subject: Online Form Submittal: Residential Window/Door Replacement Permit Application Residential Window/Door Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WINDOWS and DOORS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM AND WINDOW/DOOR CUTSHEET (SPEC SHEET) IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes replacement window(s) and/or door(s) like for like? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address **REQUIRED** Attach Credit Card Authorization Form - **DO NOT ATTACH RANDOM DOCUMENTS 4580 Teller St John Babcock 303-425-5117 jbabcock4@comcast.net BabcockCC Auth.pdf CONTRACTOR INFORMATION Contractor Business Champion Window Co of Denver Name 1 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address Retype Contractor Email Address DESCRIPTION OF WORK Number of window and/or doors being replaced Location of window(s)/door(s) being replaced (for example, master bedroom, kitchen, bathroom, etc): What is the u -value of the window(s)/door(s)? City of Wheat Ridge requires the u -value to be .32 or better on windows.. Attach copy of window/door cut sheets showing sizes and a -value Project Value (contract value or cost of ALL materials and labor) 020146 303-375-0745 shemans@getchampion.com shemans@getchampion.com 0 bedrooms and bathroom .28 Babcock.pdf 4128.00 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit z issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Steve Hemans Permit Email not displaying correctly? View it in your browser. INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day PERMIT: }) ADDRESS: "75 (& a .���� JOB CODE: /C Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS PERMIT: ,,���(" ADDRESS: JOB JOB CODE: Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial jz 9 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential jz 9 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. I i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: '- I ---> -S f d�_. Job Address: `I'S —,,- d -Fc 1; Y Permit Number: `� w 3 ❑ No one available for inspection: Time' / AA /PM Re -Inspection required: YesQ� When corrections have been made, call for re -inspection at 303-234-5933 Date: ;l _� �.\ 1 Inspector._ DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201703529 PERMIT NO: 201703529 ISSUED: 07/10/2017 JOB ADDRESS: 4580 Teller ST EXPIRES: 07/10/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration TruDef Driftwood asphalt shingles with ROOF DECKING - 37 sq. *** CONTACTS *** OWNER (303)425-5117 BABCOCK FAMILY TRUST SUB (303)922-7663 Chuck Cooper 022034 Kape Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: R-3 / Residential SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 14,800.00 FEES Total Valuation 0.00 Use Tax 310.80 Permit Fee 283.55 ** TOTAL ** 594.35 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved mi.droof inspection, conducted when 25-75 percent of the roof covering is installed, prior_ to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will riot be completed. c-0 t-703 52..E �s T��;Ex1- �- INSPECTION RECORD INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Occupancy/Type )0� Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Wall Sheathing Sewer Service Mid -Roof Plumbing Do Not Cover Under round or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric' Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this_perm�t. I further attest that I am le�lly authorized to include all entities named within this document as parties to the work to be per ormed and that all ycorj€ to be per- dr is disclosed in this document and/or its' accompan ing approved plans and specifications. Signature,of O_WN�or C T ACTOR (Circle one) Date 1. ThisW- rm'it was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a ermit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordir;;ce or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Offcia Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Residential Solar PERMIT - 201800357 PERMIT NO: 201800357 ISSUED: 02/05/2018 JOB ADDRESS: 4580 Teller ST EXPIRES: 02/05/2019 JOB DESCRIPTION: Installation of grid -tied (no batteries) PV. Flush mounted to roof. *** CONTACTS *** OWNER (303)425-5117 BABCOCK FAMILY TRUST SUB (303)447-0300 Jeff Denovan 090413 Namaste Solar *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: R-3 / Residential SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 0.00 FEES Res Solor Review 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this_perm�t. I further attest that I am le�lly authorized to include all entities named within this document as parties to the work to be per ormed and that all ycorj€ to be per- dr is disclosed in this document and/or its' accompan ing approved plans and specifications. Signature,of O_WN�or C T ACTOR (Circle one) Date 1. ThisW- rm'it was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a ermit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordir;;ce or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Offcia Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. FOR OFFICE USE ONLY City of Date: /4�-1/2CDi W heat �idge COMMUNITY DEVELOPMENT Plan/Per 't# Building & Inspection Services Division/ Fhb 35 7500 W. 291h Ave., Wheat Ridge, CO 80033 Plan Review Fee: • ,� Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 4580 Teller St. Wheat Ridge, CO Property Owner (please print):y•ecc Kr {`,CmCPhone: �f�5 `fZs SI Property Owner Email:jbabcock4@comcast.net Mailing Address: (if different than property address) Address: same City, State, Zip: Arch itect/Engineer: Architect/Engineer E-mail: Phone: Contractor: Namaste Solar Contractors City License #: 010413 Phone: 303 447-0300 x278 Contractor E-mail Address: Jnaab@namastesolar.com Sub Contract Rt C E I V E D Electrical: Plumbing: Mechanical: W.R. City License # FEB 0 5 2i0,' U W. R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑■ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Installation of grid -tied (no batteries) PV. Flush mounted to roof. 5.49 kW Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) t 15,750 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED PEPARESr NTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: Justin Naab SIGNATURE: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: Al:,pkOV12:D PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY DATE: Z q OCCUPANCY CLASSIFICATION: leyBuilding Division Valuation: $ 1 e? 1VX Incorporated 1319 Spruce Street Boulder, CO 80302 303.444.1951 ifA)OJVajva corn February 22, 2017 Namaste Solar Electric www.lvajva.com 4571 Broadway Street Boulder, CO 80304 RE: Flush Mount Solar Photovoltaic Structural Installation JVA Project No. 18567 At your request we have prepared this letter regarding the ability of existing roof structures to resist the superimposed dead load of the photovoltaic (PV) flush -mount systems for residential dwellings. This letter outlines prescriptive requirements, and if fulfilled, the added dead load of the proposed PV system will not overstress the existing structure and the flush mount modules will not add additional wind loads to the roof framing. All other systems that do not meet the prescriptive requirements of this letter will required design by an engineer registered in the State of Colorado. Furthermore, this letter is only for the exclusive use between Namaste Solar and JVA. It does not apply to any other installation by any other solar PV provider. A project will qualify as a prescriptive installation with an acceptable supporting roof structure if all of the following criteria are met: 1. System Type: Unirac Corporation, Solar Mount Rail or IronRidge XR rail with a maximum height of 12" off the roof surface. JVA understands that this installation method has been approved by a licensed engineer in the State of Colorado. Each module shall be supported by a minimum of two rails. 2. Solar Module Layout: The solar modules shall not hang below the eave of the roof system, or extend beyond the edge of the roof, nor shall it pass the plan perpendicular to the array roof surface at the ridge. 3. Roof Framing: The supporting roof framing must be of typical residential construction with multiple pre-engineered wood trusses with a minimum truss chord size of 2x4 and a maximum spacing of 24 -inches or a minimum rafter size of 2x6 and a maximum spacing of 48 -inches. All tied -rafter roof systems are excluded from general approval and will require site-specific engineering. 4. Roof material: Roof material must be either single layer composition, wood or shake shingle. Multiple layers of roof material are not covered by this letter. Concrete or tile roofs require specific engineering. 5. Standoff Roof Brackets: IronRidge Flashfoot2, Quickmount, Zilla XL, and Zilla Double stud are all appropriate brackets. JVA understand that each of these brackets are analyzed and sealed by another engineer licensed in the State of Colorado or have been evaluated by the ICC Evaluation Service. 6. Roof Connectors: All standoff base plates shall have connectors as recorSngllka d qy th manufacturer and placed in the middle third of the rafter or truss top chord.rd Vl*" diameter lag screws with minimum 2" of embedment into the primary ro* l/4" diameter Simpson SDS screws with 2 1/z" of embedment into primary ro B O U L D E R F O R T C 0 L L I N S W I N T E R P A R K G LE N W O O D SPRI NGS D E N V E R Flush Mount Solar Photovoltaic Installation February 22, 2017 Page 2 of 2 5/16" GRK RSS Wood Screw with 2 %2" of embedment into primary roof framing are all appropriate. 7. Dead Load and Snow Load: The total dead load weight of the solar modules and racking does not exceed 5 pounds per square foot (psf). The roof snow load does not exceed 30 psf. 8. Wind Loading: The wind loading analysis is based on 4'-0" spacing of standoff base plates and rail spans. Therefore, the maximum ultimate allowable wind loading parameters are 170 mph, 3 second gust, exposure C, roof zone 2; 170 mph, 3 second gust, exposure B, roof zone 3; and 140 mph, 3 second gust, exposure C, roof zone 3 as defined in ASCE, 7- 10. Any wind load parameter in excess of the listed conditions will require site-specific engineering. Based on the prescriptive requirements, the PV panel mounting system attaches to the existing roof with standoff baseplates spaced at a maximum of 48 inches perpendicular to the joist span. As a means to help define the prescriptive criteria, enclosed with this letter is Namaste PV Structural Requirement, No. NSE2009-075, dated August 19, 2009. If the installation meets all of the parameters of the prescriptive requirements, we would conclude that the roof framing is adequate for support of the solar installation. Please contact me if you have questions. Sincerely, JVA, INCORPORATED /� • ,�,,i Reviewed By: ti � C...�'' By: Brett A. Robinson, P.E. Senior Project Manager Mark CGCormicr, Vice President DO �p,4C ..6. coq , IT m:o� 2379070; . ri L C Life's GI product 12 2 �arra� y . LG320N1C-G4 I LG315N1C-134 I LG310N1C-G4 I LG305MC-G4 LG's new module, LG NeONT" 2, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires T APPROVED PRODUCT to enhance power output and reliability. LG NeONT"" 2 pVE E1� vs 60 cell demonstrates LG's efforts to increase customer's values C E -s beyond efficiency. It features enhanced warranty, durability, Intertek � . KM 561573 BS EN 67215 performance under real environment, and aesthetic P"orwalraic Modules design suitable for roofs. QEnhanced Performance Warranty ,• High Power Output LG NeONT"" 2 has an enhanced performance warranty. Compared with previous models, the LG NEONT"" 2 The annual degradation has fallen from-0.7%/yr to has been designed to significantly enhance its output -0.6%/yr. Even after 25 years, the cell guarantees 2.4%p efficiency, thereby making it efficient even in limited space. more output than the previous LG NeONr" modules. Aesthetic Roof Q Outstanding Durability LG NeCINTM 2 has been designed with aesthetics in mind; With its newly reinforced frame design, LG has extended thinner wires that appear all black at a distance. the warranty of the LG NeONTM 2 for an additional The product may help increase the value of 2 years. Additionally, LG NeCINTM 2 can endure a front a property with its modern design. load up to 6000 Pa, and a rear load up to 5400 Pa. �•; Better Performance on a Sunny Day Double -Sided Cell Structure • LG NeCINT" 2 now performs better on sunny days thanks The rear of the cell used in LG NeCNT"" 2 will contribute to to its improved temperature coefficiency generation, just like the front; the light beam reflected from the rear of the module is reabsorbed to generate a great amount of additional power. city of About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity, based on solar energy business as its future growth engine. We embarked o solar energy saurce research program in 1985 supported by LG Group's rich experience in semi -conductor, LCD, chemistry, and materials industry. We successfully released first Mono X• series to the market i 2 10,;ch were exported to 32 countries in the following 2 years, thereafter. In 2013, NeONT" (previously known as Mono X• NeON) & 2015 NeON2 with CELLO technology won °Intersolar Award", which p Q e� Lt WWW lead&of Innovation in the industry. LG NeON-z Mechanical Properties Cells 6 x 10 LG320N1C-G4 I LG315N1C-G4 I LG31ON1C-G4 I LG305N1C-G4 Cell Vendor LG Cell Type Monocrystalline / N -type Cell Dimensions 156.75 x 156.75 mm / 6 inches a of Busbar 12 (Multi Wire Busbar) ISM Dimensions (L x W x H) 1640 x 1000 x 40 mm 64.57 x 39.37 x 1.57 inch Front Load 6000 Pa / 125 psf 1 Rear Load 5400 Pa / 113 psf Weight 17.0 t 0.5 kg / 37.48 t 1.1 lbs Connector Type MC4, MC4 Compatible, IP67 Junction Box IP67 with 3 Bypass Diodes Length of Cables 2 x 1000 mm / 2 x 39.37 inch Glass High Transmission Tempered Glass Frame Anodized Aluminum Certifications and Warranty Certifications IEC 61215, IEC 61730-1/-2 IEC 62716 (Ammonia Test) IEC 61701 (Salt Mist Corrosion Test) ISO 9001 UL 1703 Module Fire Performance (USA) Type 2 (UL 1703) Fire Rating (for CANADA) Class C (ULC/ORD C1703) Product Warranty 12 years Output Warranty of Pmax Linear warranty* . 1) 1 st year 98%, 2) After 2nd year 0.6%p annual degradation, 3) 83.6% for 25 years Temperature Characteristics �s eo NOCT 46 t 3"C Pmpp -0.38 %/*C 0 Voc -0.28 %/*C Isc 0.03 %/*C Characteristic Curves 3 ,Opo 3@ a o0 600 _. __... NOW a00W 4.00 00 20t1w \tl1 vuh.eeM 0.00 5.00 1000 1500 2000 25.00 30.00 35.00 .ON 45.00 E IM ® LG North Amenca Solar Business Team LG Electronics USA. Inc Life's Good 1000 Sylvan Ave, Englewood Cliffs, N107632 Contact: Ig.so la rCallge.co m www.Igsolaruss.com mm.raw. ("U Electrical Properties (STC * Module Type 320 W 315W 310 W 305 W MPP Voltage (Vmpp) 33.6 vm.. o .2s o 2s so �s eo ® LG North Amenca Solar Business Team LG Electronics USA. Inc Life's Good 1000 Sylvan Ave, Englewood Cliffs, N107632 Contact: Ig.so la rCallge.co m www.Igsolaruss.com mm.raw. ("U Electrical Properties (STC * Module Type 320 W 315W 310 W 305 W MPP Voltage (Vmpp) 33.6 33.2 32.8 32.5 MPP Current (Impp) 9.53 9.50 9.45 9.39 Open Circuit Voltage (Voc) 40.9 40.6 40.4 40.1 Short Circuit Current (Isc) 10.05 10.02 9.96 9.93 Module Efficiency (%) 19.5 19.2 18.9 18.6 Operating Temperature (*C) -40-+90 Maximum System Voltage (V) 1000 Maximum Series Fuse Rating (A) 20 Power Tolerance (%) 0-+3 ' STC (Standard Test Condition). Irradiance 1000 W/m2, Module Temperature 2S *C, AM 1,5 The nameplate power output Is measured and determined by LG Electronics at Its sole and absolute ' The typical change in module effiaency at 200 W/m' in relation to 1000 W/m' is -2.0%. Electrical Properties (NOCT*) discretion. Module Type 320 W 315W 310 W 305 W Maximum Power (Pni 234 230 226 223 MPP Voltage (Vmpp) 30.7 30.4 30.0 29.7 MPP Current (Impp) 7.60 7.58 7.54 7.49 Open Circuit Voltage (Voc) 37.9 37.6 37.4 37.1 Short Circuit Current (Isc) 8.10 8.08 8.03 8.01 * NOCT INommal Operating Cell Temperature) Irradiance 800 W/m', ambient temperature 20'C, vend speed 1 ruts Dimensions (mm/in) 't `s IFH 0`-'� D.- -Y -- Sln•11.- - The distance between the center of the moon, n,gn).o"mmni Product specifications are subject to change without notice. DS -N2 -60 -C -G -F -EN -50427 Copyright 0 2016 LG Electronics. All rights reserved. 01/01/2016 �LI Innovation for a Better Life J d r. sm_Starling Madison Lofquist, Inc. Consulting; Structural and Forensic Engineers 5224 South 39" Street, Phoenix, Arizona 85040 tel: (602) 438-2500 fax: (602) 438-2505 ROC#291316 www.smleng.com IronRidge March 14, 2016 1495 Zephyr Ave Page 1 of 20 Hayward, CA 94544 Attn: Mr. David F. Taggart, Vice President Products Subject: IronRidge XR100 Rail, Roof Flush Mounting System — Structural Analysis Dear Sir: We have analyzed the IronRidge XR100 Rail for the subject solar module support system and determined that, for the configurations and criteria described below, it is in compliance with the applicable sections of the following Reference Documents: Codes: ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures International Building Code 2015 Edition International Residential Code 2015 Edition Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Modules, dated Effective November 1, 2012 by ICC -ES Aluminum Design Manual, 2015 Edition The IronRidge XR100 Rail is an extruded aluminum section with an overall depth of 2.438 in. and a net area of 0.583 sq.in. The rails are used to support solar modules, typically, on the roof of a building. See Exhibit 0011— attached. The modules are clamped to the rails by the IronRidge Module Mounting Clamps as shown in the attached Exhibit. The rails are attached to the L -Foot aluminum angle brackets that are either attached directly to the roof framing or attached to a stand that is screwed to the roof framing. The rails are mounted across the slope with a small clearance (flush mounting) to the underlying roof structure. The installed solar modules are at the same slope as the underlying roof structure. All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of the rails. The maximum span of the rails is governed by either the mid -span flexural stresses or the deflection requirement that the rail not come into contact with the roof. The effect of seismic loads (for all design categories A -F) have been determined to be less than the effect due to wind loads in all load conditions and combinations. Therefore, the maximum allowable spans for common load cases are shown in the tables below. Tables IA -9A are for modules with a maximum long dimension of 67.5 inches and Tables 1B -9B are for modules with a maximum long dimension of 78.5 inches. Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers IronRidge March 14, 2016 Mr. David F. Taggart Page 20 of 20 IronRidge XR100 Rail, Roof Flush Mounting System — Structural Analysis Notes — Tabulated values are based on the following criteria: 1. Building mean roof height = 30 ft 2. Risk Category I 3. Solar maximum module long dimension is 67.5 inches for Tables 1 A -9A and 78.5 inches for Tables 113-913. 4. Provide 2 in. clear between roof and rail 5. End cantilever span (max) = 0.40 x maximum span (Lmax) from above tables. See Figure A 6. No rail splices in outer 2/3 of end spans, or the middle 1/3 of interior spans based on the installed attachment spacing (L;,,Stau). See Figure A 7. Single simple span(s). Spans listed in the tables above may be multiplied by 1.08 for continuous rails of 3 or more spans. 8. Module Mounting Mid Clamps shall not be installed less than 20 inches from Roof Zone 3 where wind speeds are marked with an * in Tables 313 and 6B. End Span Interior Span End Span T- 0.4 L—, L; sw, TYP 1 /3 L; ,,,,, TY Fi u L— = Maximum attachment spacing provided in the tables above for the project design criteria L .. = Actual installed attachment spacing ® = Indicates region of the rail where splice may be installed Our analysis assumes that the rails, including the connections and associated hardware, are installed in a workmanlike manner in accordance with the "IronRidge Flush Mount Installation Manual" by IronRidge and generally accepted standards of construction practice. Additional information is available at the IronRidge web site, IronRidge.com. Verification of PV Module capacity to support the loads associated with the given array shall be the responsibility of the Contractor or Owner and not IronRidge or Starling Madison Lofquist. The adequacy of the supporting roof framing is to be determined by others. Please feel free to contact me at your convenience if you have any questions. Respectfully yours, Tres Warner, P.E. Design Division Manager Starling Madison Lofquist, Inc. -20- _ ..... -,a -mp 1°%3 fly Consulting Structural and Forensic Engineers 0 C'4 cc < C) < LU 1 LU 8 LL CN F- - LU < 1 F- < F- 0 u LU U x 0 O LL LLJ C:) Q) oC, -U c� E 0 �, 7 Z T C)U,<,� + Q) 9- —xk7 O Ln V) Fri z O� C) 0 LU O Q)O7X 0 0 0 LU V) 0 0 < 0 co > H 6 (D Z - - - 0 < Z ly- - 0 0LLJ Q U V) LU < > LU > Z I < <U U Ln — — — CL F-1 City city of — — — — — — -- — — — — — — — — — — — — Wh t R i,,l —i — — — — — — — r, I-f�' p LU eu;lding Di, �ng I-- ui — ------ --------------- ------- ui ---- W o O LL- LO Z O N > Q w J O O H Q o w Q ILO w C J C) � LU V Q O �� 1 (D X Q �U D "- o 0 � X2 O N LU 2. O O �. O O U `L J U � N O D O > z U J_Q W J_ LU Q J (n F- Q pU V) M O N � O LL O �0 o, �w Ag O o � O D X x o Q 0 N LLI oB ai — p0 C� < �} 0 m w X > IL O 0,0 m = W O �o o \ Q o- O O O 0 Qi LL � Q O a �U O w W .� O :2m z O J U— r Z C� L LL O O X Lu C) s X �Q 0 M O M P m W XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. i �7 XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves 6 foot spans, while remaining light and economical. 6' spanning capability Moderate load capability Clear & black anodized finish Internal splices available Rail Selection XR100 XR 100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. 8' spanning capability Heavy load capability Clear & black anodized finish Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. 12' spanning capability Extreme load capability Clear anodized finish Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. None 10-20 30 40 50-70 80-90 100 120 140 160 100 120 140 160 100 160 100 160 160 WOR XR100 XR1000 020141` 96, fic.° "0' fto`ge ao ri oI .. " __ ._ :. IRONRIDGE For Greater Safety & Lower Cost Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners. 2 Grounding Strap Grounding Straps are used to bond rail -to -rail connections. They are only required on the rail with the grounding lug. Integrated Grounding System Grounding Mid Clamp Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and the mounting rail to form secure electrical bonds, which are repeated throughout the array. / 3 WMW amp Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Installation Overview Install Roof Attachments • Install appropriate roof flashing and/or standoff for roof type. • Attach L -Feet to flashing or standoff. Prepare Rail Connections • Insert splice into first rail, then secure with Grounding Strap and self -drilling screw. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. Mount & Ground Rails • Attach rails to L -Feet and level rails. • Install one Grounding Lug per row of modules. • Connect Grounding Lug to grounding conductor. Install Modules & Clamps • Install first module using End Clamps and Grounding Mid Clamps. • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. The testing process closely mirrors that of UL 1703, the solar module testing standard, including temperature and humidity cycling, electrical and mechanical load testing, and manufacturing quality reviews. i Module Frame Compatibility Dimension Range A 31.Omm - 51.Omm B 5.08mm (minimum) Any module frames whose parameters are not listed in the provided table have not been tested for compatibility. The Grounding Clamp has proven robust in grounding 60 -cell and 72 -cell solar module frames with box construction and a range of anodization thicknesses. All solar modules listed to UL 1703 and with frame construction within the parameters stated above are compatible with the IronRidge Integrated Grounding System. Go to ironridge.com/ica a Module Frame Compatibility Dimension Range A 31.Omm - 51.Omm B 5.08mm (minimum) Any module frames whose parameters are not listed in the provided table have not been tested for compatibility. The Grounding Clamp has proven robust in grounding 60 -cell and 72 -cell solar module frames with box construction and a range of anodization thicknesses. All solar modules listed to UL 1703 and with frame construction within the parameters stated above are compatible with the IronRidge Integrated Grounding System. Go to ironridge.com/ica y UL 2703 LISTED #5003288 O(T�us #5003320 Intertek #5004376 • Conforms to ANSI/UL 2703 (2015) Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/ Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels • Max Overcurrent Protective Device (OCPD) Rating: 25A • Max Module Size: 24ft2 • Module Orientation: Portrait or Landscape • Mechanical Load Rating: meets minimum requirements of the standard (10 PSF downward, 5 PSF upward, 5 PSF lateral). Actual system structural capacity is defined by PE stamped certification letters. CLASS A SYSTEM FIRE RATING PER UL 1703 • Any Roof Slope with Module Types 1, 2, and 3 • Any module -to -roof gap is permitted, with no perimeter guarding required. This rating is applicable with any third -party attachment. • Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire rating. STRUCTURAL CERTIFICATION • Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7 Product markings are located on the 3/8" flange hex nut. 0 i '%g L — OU INSTALLATION MANUAL - 2 GROUNDING STRAP EXPANSION JOINT Grounding Strap Expansion Joints are required for thermal expansion of rows exceeding 100 feet of rail. Insert Internal Splice into first rail and secure with screw. Assemble and secure Grounding Strap 3/8" from rail end. Slide second rail over Internal Splice leaving 1" gap between rails. Attach other end of Grounding Strap with hardware, and torque hex nuts to 80 in -lbs. Q Second Bonded Splice screw is not used with Expansion Joints. Q Do not install module over top of expansion joint location. ilr O UFO • Grounding Lug*= Fault Current Minimum 10 AWG `r Ground Path Copper Wire` Bonded Splice (Rail Connection) 'Grounding Lugs and Wire are not required in systems using Enphase microinverters. SKI a O UFO • Grounding Lug*= Fault Current Minimum 10 AWG `r Ground Path Copper Wire` Bonded Splice (Rail Connection) 'Grounding Lugs and Wire are not required in systems using Enphase microinverters. MODULE COMPATIBILITY The Flush Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. Astronergy Solar Modules with 35, 40, and 45mm frames and model identifier aaSM66yyPzz-xxx; where "aa" can be CH or A; "yy' can be either 10 or 12; "zz" can be blank or (BL). Frameless modules with model identifier CHSM661 OP(DG)-xxx. Axitec Modules with 35 and 40mm frames and model identifier AC-xxxY/aa-ZZ; where "Y" can be M or P; "aa" can be 125 or 156; and "ZZ" can be 54S, 60S or 72S. Canadian Solar Modules with 40mm frames and model identififer CS6Y-xxxZ; where "Y" can be K, P, V, or X; and ""Z"" can be M, P, PX, or P -SD. Uframed modules with model identifier CS6Y-xxxP-FG; where ""Y"" is K or X. ET Solar Modules with 35, 40, and 50mm frames and model identifier ET-Y6ZZxxxAA; where "Y" can be P, L, or M, "ZZ" can be 60 or 72; and "AA" can be WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC. Flex Modules with 35, 40, and 50mm frames and model identifier FXS-xxxYY-ZZ; where "xxx" is the module power rating; "YY" can be BB or BC; and "ZZ" can be MAA1 B, MAA1 W, MABs W, SAA1 B, SAA1 W, SAC1 B, SAC1 W, SAD1 W, SBA1 B, SBA1 W, SBC1 B, or SBC1 W. Giga Watt Solar Modules with 40mm frames and model identifier GWxxxYY; where "YY" can be either PB or MB. Hanwha Solar Modules with 40, 45, and 50mm frames and model identifier HSLaaP6-YY-1-xxxZ; where "aa" can be either 60 or 72, "YY" can be PA or PB; and "Z" can be blank or B. Hanwha Q CELLS Modules with 32, 35, 40, and 42mm frames and model identifier Q.YY-ZZ-xxx; where "YY" can be PLUS, PRO, or PEAK, and "ZZ" can be G3, G4, L -G2, L-G3y, L-G4y, BFR -G3, BLK-G3, BFR -G4, BFR -G4.1, G4/SC, or G4.1/SC. Hyundai Modules with 35 and 50mm frames and model identifier HiS-YxxxZZ, where "Y" can be M or S; and "ZZ' can be MI, MF, MG, SG, RI, RG, TI, or TG. Itek Modules with 50mm frames and model identifier IT-xxx-YY; where "YY" can be blank, HE, or SE. Modules with 40 and 45mm frames and model identifier JAyyzz-bb-xxx/aa; where "yy" can be M6 or P6; "zz" can be blank, (K), (L), (R), (V), (BK), JA Solar (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R)(T(3), (V)(SK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, or 72; and "aa" can be MP, SI, PR, 3BB, 4BB, 4BB/RE. Jinko Modules with 35 and 40mm frames and model identifier JKMYxxxZZ; where "Y" can either be blank or S; and "ZZ" can be M, P, PP, P -B, or P -V. Frameless modules with model identifier JKMxxxPP-DV. Kyocera Modules with 46mm frames and model identifier KYxxxZZ-AA; where "Y" can be D or U; "ZZ" can be blank, GX, or SX; and "AA" can be LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2, LPB2, 3AC, 36C, 3FC, 4AC, 413C, 4FC, 4UC, 5AC, 5BC, 5FC, 5UC, 613C, 6FC, 813C, 6MCA, or 6MPA. Modules with 35, 40, and 46mm frames and model identifier LGxxxy1 z -bb; where "y" can be A, N, or S; "z" can be C or K; and "bb" can be A3, B3, LG G3, C4 or K4. Mitsubishi Modules with 46mm frames and model identifier PV-MYYxxxZZ; where "YY" can be LE or JE; and "ZZ" can be either HD, HD2, or FB. Motech IM and XS series modules with 40, 45, and 50mm frames. Panasonic Phono Solar Prism Solar REC Solar Renesola Renogy Silfab SolarWorid Stion SunEdison Suniva Modules with 35mm frames and model identifier VBHNxxxSAyy; where "yy" can be either 06, 0613, 11, 11B, 15,15B, 16 or 16B. Modules with 35, 40, or 45mm frames and model identifier PSxxxY-ZZ/A; where "Y" can be M or P; "ZZ" can be 20 or 24; and "A" can be F, T or U. Frameless modules with model identifier BIYY-xxxBSTC, where "YY" can be 48 or 60. Modules with 38 and 45mm frames and model identifier RECxxxYYZZ; where "YY" can be M, PE or TP; and "ZZ" can be blank BILK, SLV, or 72. Modules with 35, 40 and 50mm frames and model identifier JCxxxY--ZZ; where "Y" can be F, M or S, and "ZZ" can be Ab, Ab -b, Abh, Abh-b, Abv, Abv-b, Bb, Bb -b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db -b. Modules with 40 and 50mm frames and model identifier RNG-xxxY; where "Y" can be D or P. Modules with 38mm frames and model identifier SYY-Z-xxx; where "YY" can be SA or LA; SG or LG; and "Z" can be M, P, or X. PSu- nmodule Plus Protect XL, Bisun, Bisun XL, may be followed by mono, poly or duo and/or black or bk; modules with 31, 33 or 46mm frames and odel identifier SW-xxx. Thin film modules with 35mm frames and model identifier STO-xxx or STO-xxxA. Thin film frameless modules with model identifier STL-xxx or STL-xxxA. Modules with 35, 40, and 50mm frames and model identifier SE-YxxxZABCDE; where "Y" can be B, F, H, P, R, or Z; "Z" can be 0 or 4; "A" can be B, C, D, E, H, I, J, K, L, M, or N; "B" can be B or W; "C" can be A or C; "D" can be 3, 7, 8, or 9; and "E" can be 0, 1 or 2. Modules with 35, 38, 40, 46, and 50mm frames and model identifiers OPTxxx-AA-B-YYY-Z or MVXxxx-AA-B-YYY-Z; where "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either 100,101,700,1 BO, or 1131; and "Z" is blank or B. Sunpower SPR-A-xx series with standard (G3) or InvisiMount (G5) 46mm frames; where "A" is either E or X; and "xx" is the series number. Sunpreme Frameless modules with model identifier GXB-xxxYY; where "YY" can be blank or SL. Suntech 1 Vd, Vem, Wdb, Wde, and Wd series modules with 35, 40, and 50mm frames. _D-.._. Modules with 35, 40 and 46mm frames and model identifier TSM-xxxYYZZ; where "YY" can be PA05, PCOS, PDOS, PAI 4, PC14, P 4, or?DD05; Trina and "ZZ" can be blank, A, A.05, A.08, A.10, A.18, .05-08-10-18-081), .18D, 0. 82, A.082(Ip, .002, .00S, 05S, 08S, A(II), A.08(II), A.05(11), A.10(11), or A.18(II). Frameless modules with model identifier TSM-xxxYY; and "YY" can be either PEG5, PEG5.07, PEG 14, DEG 5(II), DEG5.07(II), or DEG 14(11). Winaico Modules with 35 and 40mm frames and model identifier Wsy-xxxz6; where "y" can be either P or T, and ""z"" can be either M or P Yingli Panda, YGE, and YGE-U series modules with 35, 40, and 50 mm frames. :iiC.'i��:�.�im7i"�+�ioai"i"� ® � solar -•. SolarEdge Single Phasi For North America SE3000A-US / SE380OA-US / SE5000A SE760OA-US / SE10000A-US / SE11400 erte, :12.25 • so, . #i t I Y The best choice for SolarEdge enabled systems Integrated arc fault protection for NEC 2011690.11 compliance Rapid shutdown for NEC 2014 690.12 Superior efficiency (98%) Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.20 USA -GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA -THE NETHERLANDS -UK -ISRAEL www.solaredge.us solar=@@ Single Phase Inverters for North America SE3000A-US / SE380OA-US / SE5000A-US / SE6OOOA-US / SE760OA-US / SE1000OA-US / SE1140OA-US SE3000A-US SE3800A-US SESOOOA-US SE6000A-US1 SE760OA-US 1 SE1000OA-US SE1140OA-US OUTPUT Maximum DC Power(STC) 4050 5100 6750 .. .. ..... Nominal AC Power Output _ _ 3000 W 3800 � _. I 5000' I 6000 1 7600 9980 @ 208V 1 ( 11400 500 ..... ........................ ................. �...Vdc... Nom :DC Input Voltag?................ ............... .............. ............ 325 @ 298Y.05q 350 @,240V.... ..... ........... .... I Vdc 10000 240V .......... Max. AC Power Output 1 3300 .W. WxQ).............................. 4150 5400 @ 208V 6000 .. 8350 10800 @ 208V 12000 15.5 �1a 240V .1......18.......1...... ._,...... 23.......1..3,0,.5 Qa?2 OV.. 5450�A240V, .... Max. Input Short Circuli Current ........... .... .............. .............. ...........I..... 45 ...................................... AC Output Voltage Min: Nom: Max,l'I Reverse Polarity Protection Yes ................ ......... Ground -Fault Isolation Detection ........................................ ......... 600ka Sensitivity .............. .......,,..,,.. ........... 183 - 208 - 229 Vac Maximum inverter Efficiency ............................. 97.7 .............. 98.2 . .. . 98.3 .. . ... 98.3 .............. I 98......1.......98.......1...... .... . .............. 98 �,...'Y.... AC Output Voltage Min: Nom: Max!'l replaceable)„ ........ I ........ ..... 97 @ 208V (......@ Noise 97 @ 208V ........... . . % ........... � 211- 240 - 264 Vac ..... 98 240V ............. 97.5......1........5......) Range ..................................... �..,.....I......97.5......1.. 97.5, 240V ................................................................. Nighttime Power Consumption < 2.5 ....................................... AC Frequency Min.:Nom: Max!t) ... . .. ADDITIONAL FEATURES ............. 59.3 - 60 - 60.5 .............. isl For other regional settings please contact SolarEdge . • ....... ...... . ... . Max Continuous Output Current ( 125 ul A higher current source may be used; the inverter 16 24 @ 208V 1 25 1 32 . .......... 48 @ 208V ( 47 5 ........................... ...... ...... . 21.Q). 240V .................. ........... 42. �.240V... .... . GFDI Threshold � ............................ ...,.,.... ...............................................I.......I.................I. 1 Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes .................i VA VA INPUT Maximum DC Power(STC) 4050 5100 6750 .. .. ..... 8100 10250 13500 15350 W Transformer -less, UnSrounded ......... . ... .......... Yes ........................... . ................ Max.lnPut Voltage .................... ) ............ .............. ................ 500 ..... ........................ ................. �...Vdc... Nom :DC Input Voltag?................ ............... .............. ............ 325 @ 298Y.05q 350 @,240V.... ..... ........... .... I Vdc Max: Input Currents') 30:5 x 12.5 x 10.5 / in / .W. WxQ).............................. I...... .. ......................9.5......1......13...... Weight with Safety Switch ........... .................... 1......... 15.5 �1a 240V .1......18.......1...... 23.......1..3,0,.5 Qa?2 OV.. 34.5......I...Adc... Max. Input Short Circuli Current ........... .... .............. .............. ...........I..... 45 ...................................... Adc Reverse Polarity Protection Yes ................ ......... Ground -Fault Isolation Detection ........................................ ......... 600ka Sensitivity .............. .......,,..,,.. ........... Fans (user replaceable) Maximum inverter Efficiency ............................. 97.7 .............. 98.2 . .. . 98.3 .. . ... 98.3 .............. I 98......1.......98.......1...... .... . .............. 98 �,...'Y.... CEC Weighted Efficiency replaceable)„ ........ I ........ ..... 97 @ 208V (......@ Noise 97 @ 208V ........... . . % dBA ...97.5.....1......98.1. ..... 98 240V ............. 97.5......1........5......) Range ..................................... �..,.....I......97.5......1.. 97.5, 240V ................................................................. Nighttime Power Consumption < 2.5 Protection Rating ( < 4 tAl ADDITIONAL FEATURES isl For other regional settings please contact SolarEdge support. Supported Communication Interfaces RS485, RS232, Ethernet, ZigBee (optional) 1 ........................................ . . ............................................................................... ................ ....... Revenue Grade Data, AN51 C12.20 ( Optionallll ..................................... .............. ................................................................................................� ......... Rapid Shutdown - NEC 2014 690.12 1 Yes 1 STANDARD COMPLIANCE Safety .......................... UL1741, - UL1741 SA, UL1699B, UL1998 ,CSA 22.2 ....... .. . .............. ................................................................ ................ .......... Grid Connection Standards IEE 1547 1 .............. .............. ................................ .................I.......... p Emissions FCC art15 class B INSTALLATION SPECIFICATIONS AC output conduit size / AWG range ...........i........... 3/4" minimum / 16-6 AWG ...................................................................................... 3/4" minimum / 8-3 AWG DC input conduit size / k of strings / 3/4' minimum / 1-2 strings / 16-6 AWG 3/4" minimum / 1-3 strings / AWG rangf........................... ........................ 14-6 AWG Dimensions with Safety Switch 30:5 x 12.5 x 7.2 / 775 x 315 x 184 30:5 x 12.5 x 10.5 / in / .W. WxQ).............................. 775,x 315 x 260.........l...m!r?... Weight with Safety Switch ........... .................... 1......... 51.2/23.2 .........1 54.7 / 24:7 88.4/40.1 %40.1 ................ ................. Ib /.kg Natural convection Cooling Natural Convection and internal Fans (user replaceable) fan (user ........................................ ........................................... replaceable)„ ........ I ........ ..... . Noise < 25 < 50 dBA ............... ................... ...... Min: Max. Operating Temperature ............... .............. .................... ..... ........... ..... . . . ....... .. . ........... -13 to +140 / -25 to +60 (-40 to +60 version available(4) ) 1 'F /'C Range ..................................... .......... ................................................................. Protection Rating NEMA 3R ............................ isl For other regional settings please contact SolarEdge support. ................. .......... ul A higher current source may be used; the inverter will limit its input current to the values stated. I3l Revenue grade inverter P/N: SExxxxA-USOOONNR2 (for 7600W lnverter:SE7600A-US002NNR2). (41-40 version P/N: SExxxxA-USOOONNU4 (for 7600W lnverteCSE7600A-US002NNU4). solar =e" SolarEdge Power Optimizer Module Add -On For North America P300 / P320 / PV power optimization at the module -level — Up to 25% more energy —Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization - Fast installation with a single bolt •- Next generation maintenance with module -level monitoring Module -level voltage shutdown for installer and firefighter safety USA -CANADA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK -ISRAEL www.solaredge.us so I a r- • • SolarEdge Power Optimizer Module Add -On for North America P300 / P320 / P400 / P405 P300 ] '320 P400 P405 (for 60 -cell modules) (for high-power (for 72 & 96 -cell (for thin film I_L— 60 -cell modules) modules) modules) -.—i— INPUT INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage ....................... . Rated Input DC Poweri'i �s—i 300 _ 320 40.0. 405 W Absolute Maximum Input Voltage 128x152x27.5/ 128x152x35/ 128x152x50/ I 48 80 125 Vdc Voc at lowest tem erature Wei ht, includin .cables .. gs..( ......g. 1 .............1.......... 760 1.7 830 ............... ............. /...........................1.............1.8 I.......1064./2:3.......l..gr/fib... .................................................... 6000 ....................... Input Connector MPPT Operating Range (....................... 8 - 48........... I 8 - 80 ( 12.5 105 I vas..... ................ Maximum Short Circuit Current Isc ...1........................................................I........................10..1....... 10 . 11 .................. .... I...Adc.... Maximum DC Input Current ............... 1 12.5 1 13.75 .........1... 12.63 .............. 1. Adc Maximum Efficienc Y ............................................... 96 99.5 ................................. ................... ............ I %. Wei&hted Efficiency.....................I................................................... 98.8 ) ... �0...... Overvoltage Category 1 II 1 ... OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) OUTPUT DURING OPERATION (POWER Maximum Output Current 15 Adc ............Outp. t Voltage ..............I.....................................................I Maximum Output Volta a ............................ ............................ 60 85 � Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 I Vdc Optimizer L STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000.6-2t IEC61000-6-3 RoHS....................................1................,.............IEC62109 1 (claYesl safetY)s UL1741 ... i............. INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage ....................... . 1.000 Vdc Compatible,inve. ers .. ..... ........................ 1 All SolarEdge Single Phase and Three Phase inverters . ............... . . .. ..................... . g.. . ............. 18 ............................ Dimensions (W x L x H) 128x152x27.5/ 128x152x35/ 128x152x50/ I mm/in ..................................... ................. 5 x 5:97 x.1:08._.., ....... ,.....I.....5.x 5:97 x 1.37 5 x 5.97 x 1.96 50 Wei ht, includin .cables .. gs..( ......g. 1 .............1.......... 760 1.7 830 ............... ............. /...........................1.............1.8 I.......1064./2:3.......l..gr/fib... .................................................... 6000 ....................... Input Connector I. , . . .. , MC4 Compatible1 ..................................... .. output WIre,Type./ Connector I Double Insulated, MC4 Compatible 1 Output Wlre Length 1 0..9.5/.3.0. 1 1 2/ 3 9 ..........I .... ................... . 1 Operating Temperature Range 1-40 ... - +85 / - ............-40.........+185............................................. C /F 1 Pro on Rating .IP68 ....................... / NEMA6P Relative Humidity ( ................... 0.- 100 1.... ........................................................................................................ 96 iii Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(') SINGLE PHASE Minimum String Length ,(Power Optimizers! ............................................................. Maximum String Length (Power Optimizers) 5 .......,. ..... Maximum Power per String 1 5250 1 Parallel Strings of Different Lengths or Orientations ................... ........... ..................................... (1) It is not allowed to mix P405 with P300/P400/P600/P700 in one string. THREE PHASE 208V THREE PHASE 480V 10 .................... 18 ............................ 25 50 .................................................... 6000 ....................... .......1 ..............12750...............1..... . W ..... ..........Yes....................................................I............. JEANNE BABCOCK 4580 TELLER STREET WHEAT RIDGE, CO 80033 SHEET INDEX SHEET NUMBER TITLE PV -G.0 COVER PAGE PV-A.I ARRAY LAYOUT PV -A.2 NO PEAK PV-E.I ELECTRICAL THREE LINE PV -E.2 ELECTRICAL CALCS PV -E.3 PLACARDS PV -E.4 PLACARDS SYSTEM DETAILS 5.490 kW DC ROOF MOUNTED PHOTOVOLTAIC SYSTEM N VICINITY MAP I its jk ,� 6 �Y iN ars PHOTOVOLTAIC SYSTEM DETAIL ITEM DETAIL QTY SYSTEM SIZE, STC, DC 5.490KW N/A MODULE RATING, STC, DC 305W 18 INVERTER SOLAREDGE-SE5000HD-US I RACKING SYSTEM IRONRIDGE XR100 N/A DATA AQUISITION SOLAREDGE CELLULAR MONITORING N/A CONTACT INFORMATION NAMASTE POINT OF CONTACT MATT JOHNSON EMAIL ADDRESS MATT. JOHNSON@NAMASTESOLAR.COM PHONE NUMBER 303.447.0300 DESIGN CRITERIA DESIGN WIND LOAD 105 MPH DESIGN SNOW LOAD 30 PSF EXPOSURE CATEGORY B HIGH TEMP (ASHRAE 2% HIGH) 34°C LOW TEMP (ASHRAE EXTREME LOW) -25°C ROOF TYPE ASPHALT SHINGLE ;'f'. AUTHORITY HAVING JURISDICTION AVXwft BUILDING AUTHORITY CITY OF WHEAT RIDGE `p`0e CODE REFERENCE 2014 NEC ELECTRICAL UTILITY COMPANY XCEL ENERGY \�co 00 N O ��n0 00' vJ n O � o � M o > °�a�iE TOTAL # OF MODULES: HANWHA Q -CELL Q. PEAK -G4.1 305W JVLHRLVUL- D'tt SE5000HD-US of permit or apprawi of pl a DWG TITLE: COVER PAGE SHEET # REVISION # PV -G.0 0 r C:. .e 8 to DESIGNER: a° �Q U � � " E C J E PHONE O Z33 303.447.0300x211 o � 3 m 3 TOTAL # OF MODULES: HANWHA Q -CELL Q. PEAK -G4.1 305W JVLHRLVUL- D'tt SE5000HD-US of permit or apprawi of pl a DWG TITLE: COVER PAGE SHEET # REVISION # PV -G.0 0 r C:. .e 8 to DESIGNER: NAME KIM ABCOUWER EMAIL KABCOUWER@NAMASTESOLAR.COM PHONE 303.447.0300x211 OWNER: r� j O U l Lu 00 Lu O O m W w a J � a Lu Lu o z z Q O00 J O v W y SYSTEM ATTRIBUTES: TOTAL # OF MODULES: HANWHA Q -CELL Q. PEAK -G4.1 305W JVLHRLVUL- D'tt SE5000HD-US of permit or apprawi of pl a DWG TITLE: COVER PAGE SHEET # REVISION # PV -G.0 0 r C:. .e 8 to 41P spy vt .VN .VN VN 7# kVHHV .VN .081 .06 .VN .81 .81 VN 6 6 �# l.VbbV Z# )IVHHV 1# lIv6aV H1nWIZV 1u11 X110 QOW # NOISIn3a # 133HS 1noJ,vl Andy 31111 JMO S1N 3IVOS sn-aHOOHs IS NOIiVW�IOANI /.ajv-sns (S)N31d13/ NI ® S"V""V MSOS 1`79-W3d'0 N -1-133-0 VHMNVH 3�naon 81 S3lnaon d0 # uviol M)1067"S 3ZIS n31SJ.S ls3innalaiiv w31SAS C rn C- D CTI rn ° o D D z A �u D - Z m Z 0 o r rn D rn m o0 m D OD C7 HOI1 ]I1X3 - 2�d1b3nNl v 0 O nNl cD m 0 m O Z o a CA CA �]Old31X3 - 103NNOOSIa OV Ad Ov Ad a3NMO IO(ON0'Z77'NSf 3NOHd '�OId31X3 - 2i313W NOIlOnaObd l.11nlln dsw WO:) NVIOS31SVWVN@82 mn009" W ,dW3 aJOlal1X3 - �3Ndd 301na3S N1VW a3Mnooev WI)4 3NVN b01N31X3 - b313W 9N1-1118 NIVW 'AVHHV 3H1 H1V3NdaNn 2i31dVb iDV1NOO d0 1NIOd a HOV3 Ol a31n81b1SIa SI aVO-1 3H1 OS a3b399V1S 38 IIVHS S1N3WHOViiV ,81 = b3n3II1NVO XVW Q ` v # S1N3WHOdl 1V d 0d 1'7 Y0 ddb' 1334 INVnOS 9N = �,VMV Ad 3 =3 0 3 d 3 �9NIHS IIVHdSV J.V-1 19NIS •�� w,s FNOliom:JiSNOO 02 �0A pwn O r 0 r V 1 co ,oIl Dm o 2: inowl )dj�jd a01OVN1NOO nvmfr Amur CONTRACTOR: VJ O > � J 0 OU Q N U # o POINT OF CONTACT: NAME KIM ABCOUWER EMAIL KABCOUWER@NAMASTESOLAR.COM PHONE 303.447.0300x211 OWNER: Pri U w 00 O O mccn U Q 0� m Lu (wu J W J z LLJ � Q O W 00 L0 Q W I SYSTEM ATTRIBUTES: SYSTEM SIZE: 5.490KW TOTAL # OF MODULES 18 MODULE: HANWHA Q -CELL Q.PEAK-G4.1 305W INVERTER(S): SOLAREDGE SE5000HD-US SCALE: NTS DWG TITLE: NO PEAK DETAIL SHEET # I REVISION # PV -A. 21 0 O > � 0 OU Q N U # o d� N �t y E C J N � Z O r � 5 POINT OF CONTACT: NAME KIM ABCOUWER EMAIL KABCOUWER@NAMASTESOLAR.COM PHONE 303.447.0300x211 OWNER: Pri U w 00 O O mccn U Q 0� m Lu (wu J W J z LLJ � Q O W 00 L0 Q W I SYSTEM ATTRIBUTES: SYSTEM SIZE: 5.490KW TOTAL # OF MODULES 18 MODULE: HANWHA Q -CELL Q.PEAK-G4.1 305W INVERTER(S): SOLAREDGE SE5000HD-US SCALE: NTS DWG TITLE: NO PEAK DETAIL SHEET # I REVISION # PV -A. 21 0 # NOISIADH I # 133HS ANIS AAHH1 1VOIalO3T3 31111 JMO SIN 3�vos sn-aH000S3S 39a3HVIoS (S)a31HAANI MSO 1 70-WAcl'O VHMNVH 3inaow 81 S3lnaoW d0 # lb'lol M�1 067' 5 3ZIS W31SAS S31n818lly W31SAS C 801831X3 3;v� � m 8 rn a01d31X3 C- D 0 rn c ° O D )MO-1I1A W d z o n m W O n i f y'^ X00 Z o m Z o IF rn o r 7 H9 VW3N 'X08 NOIlONnf, A00H Ad ),VHaV HIVANHHaNn (81 mrnm Z D a3ZIWIldO H3MOd 9NI�IOVH U) UD 39a3HV�OS 81 n D O MGM 1 79-WAd'O 1 30-0 VHMNVH I 91 1 O m co,m H3a0W n AAO ,131 O � O m CA (lJ 2J3NM0 IZXOHO,L", OF 3NOHd WOJ 2JVlOS31SVWVN@a3Mn008VA 7IVW3 a3Mn0:)8v WIN 3WVN lOv1NOO d0 1NIOd I w� zoo 801831X3 3;v� � m 8 (D (D a01d31X3 HOOZ18W07013W Q oo� L 3 0 � 3 <o )MO-1I1A W d 9 o n m W O n i f y'^ X00 � cr o�w �(D, 0 0 H01H3IX3 a010ya1NOO O V/N a OWa/lwl a lW3/OWd HIV ddHd ,IVM30VH N SH313W d0 3aIS IN1-1 OINI a3HIM Ad 'S (3)179,09Z aid snOnNIIN00 38 �IVHS O30 '7 (S)NOIldIHOS3a NOIIVOO-1 H11M a3AHVW HO/aNV Oldn0a9 38 THVHS SIO3NNOOSIa 3OIAa3S '� „a3133NN0O W31S),S OIVl-lOAOlOHd, SNIIVOIaNI a313W 1V aHVOVld 'Z 79' '7S' '�S' 'ZS 'IS' 'S2' 'LI' `71' 'S'069 Had a3a1n03a SV SNIaaVOV-Id 'I lVa3N30 S310N —lVOPJ1O3T3 ,-)-1 I I I IJ V V N V J V .l I N I V 1 J A072 'vooz 'Hd13W J,iiniln 801831X3 a8l a81 1 8 H3W3H8 dZ/V09 X I 'NIVW VOOZ 'sno VOOZ 'iANVd 3OIAH3S a01d31X3 HOOZ18W07013W SN3W31S I L H3i]W NOIIOnaOad Ad HOIa31X3 AO'7Z 'VOOZ )MO-1I1A 1 9 H9 VW3N '1O3NNOOSIa OV Ad a01H31X3 A07Z 'V0� NOIV3 1 9 H31H3ANIa31VH93IN11O3NNOOSIa Oa H01H3IX3 Sn-aH00093S 39a3HVloS 1 7 H9 VW3N 'X08 NOIlONnf, A00H Ad ),VHaV HIVANHHaNn (81 )4O3aVIOS Z 9 a3ZIWIldO H3MOd 9NI�IOVH NO a3INnow oHd 39a3HV�OS 81 Z 3Hna0W Ad d00a 01 a31NnOW HSndd MGM 1 79-WAd'O 1 30-0 VHMNVH I 91 1 S3ION NOIIVOOl H3a0W 3IWW AAO ,131 11MAHOS 1N]Wclinol 3NITAA3 IH1—lVMJiO3—l3 INVERTER SPECS AND CALCULATIONS PARAMETER UNIT CALCULATED LIMIT ITEM NOTE /CALC UNIT CONTRACTOR: INV. MAKE MODULE SPECS AND CALCULATIONS ITEM NOTE /CALC UNIT DETAIL MAX. SHORT CIRCUIT CURRENT (ISO SE5000HD-US INV. MAX POWER, (WAC MAX) 0 0 LOCATION 5000 INV. INPUT V, (VDC MAX) WHEAT RIDGE, CO 80033 VOLTS (DC) 480 INV. OUTPUT V, (VAC NOM) �A\ C, o V Q m 0 0 J TEMP, AMBIENT HIGH (TMAX) ASHRAE 2% °C 34 HERTZ 60 INV. OUTPUT CURRENT, IAC ,^ C O TEMP, AMBIENT LOW (THIN) ASHRAE EXTR. MIN °C -25 PHASE I COMPLIANCE V! H O yUp a . M TEMP, MODULE TEST (TTEST) MODULE SPEC °C 25 ZOA UNGROUNDED INV. QTY INV.QTY TEMP, DELTA LOW (TDELTA) THIN -TTEST °C -50 VOLTS (Dc) MODULE SPEC °�mE 9.84 MOD. MAX VOLTAGE (VMAXMOD) (Voc + (To*COEF)) VOLTS (Dc) 40.19 MOD. MAXIMUM CURRENT (IMAX) (Isc 1.25) N O U MOD. MANUFACTURER MODULE SPEC (IMAX 1.25) HANWHA Q -CELL 15.38 Q U # o MOD. PART NUMBER MODULE SPEC Q.PEAK-G4.1 305W AA E MOD. POWER STC (P) MODULE SPEC 305 iJ r MOD. OPERATING VOLTAGE (VMP) MODULE SPEC 32.62 C M E hoz MOD. OPEN -CIRCUIT VOLTAGE (VOC) MODULE SPEC 40.05 r 0 MOD. COEFFICIENT, VOLT/TEMP (COEFF) MODULE SPEC -0.0028 m MOD. OPERATING CURRENT (IMP) MODULE SPEC 9.35 MOD. SHORT-CIRCUIT CURRENT (ISO POINT OF CONTACT: NAME KIM ABCOUWER EMAIL KABCOUWER@NAMASTE SOLAR. COM PHONE. 303.447.0300x211 OWNER w:� Pr7 U w ao a O U C O a -) Q Ji w o m J j QD w _J Q z w - z z Qa O o Lu 0 Q U) LU SYSTEM ATTRIBUTES: SYSTEM SIZE: 5.490KW TOTAL # OF MODULES: 18 MODULE: HANWHA Q -CELL Q.PEAK-G4.1 305W INVERTER(S): SOLAREDGE SE5000HD-US SCALE: NTS DWG TITLE: ELECTRICAL CALCS SHEET # REVISION # PV -E.2 0 INVERTER SPECS AND CALCULATIONS PARAMETER UNIT CALCULATED LIMIT ITEM NOTE /CALC UNIT DETAIL INV. MAKE INVERTER SPEC 2) TERMINALS (TERM): SOLAREDGE INV. MODEL INVERTER SPEC MAX. SHORT CIRCUIT CURRENT (ISO SE5000HD-US INV. MAX POWER, (WAC MAX) INVERTER SPEC WATTS (Ac) 5000 INV. INPUT V, (VDC MAX) INVERTER SPEC VOLTS (DC) 480 INV. OUTPUT V, (VAC NOM) INVERTER SPEC VOLTS (Ac) 240 INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 INV. OUTPUT CURRENT, IAC INVERTER SPEC AMPS (AC) 21 INV. PHASE INVERTER SPEC PHASE I COMPLIANCE INVERTER SPEC 1.00 UL1741/IEEE1547 INV. GROUNDING INVERTER SPEC ZOA UNGROUNDED INV. QTY INV.QTY QTY I DC OPTIMIZED INPUT VOLTAGE VOPT VOLTS (Dc) MODULE SPEC MODaTY 9.84 MOD. MAX VOLTAGE (VMAXMOD) (Voc + (To*COEF)) VOLTS (Dc) 40.19 MOD. MAXIMUM CURRENT (IMAX) (Isc 1.25) AMPS (Dc) 12.30 MIN. AMPACITY REQ'D, PER NEC (IMAX 1.25) AMPS (DC) 15.38 INVERTER SPECS AND CALCULATIONS PARAMETER UNIT CALCULATED LIMIT ITEM NOTE /CALC UNIT DETAIL INV. MAKE INVERTER SPEC 2) TERMINALS (TERM): SOLAREDGE INV. MODEL INVERTER SPEC MAX. SHORT CIRCUIT CURRENT (ISO SE5000HD-US INV. MAX POWER, (WAC MAX) INVERTER SPEC WATTS (Ac) 5000 INV. INPUT V, (VDC MAX) INVERTER SPEC VOLTS (DC) 480 INV. OUTPUT V, (VAC NOM) INVERTER SPEC VOLTS (Ac) 240 INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 INV. OUTPUT CURRENT, IAC INVERTER SPEC AMPS (AC) 21 INV. PHASE INVERTER SPEC PHASE I COMPLIANCE INVERTER SPEC 1.00 UL1741/IEEE1547 INV. GROUNDING INVERTER SPEC ZOA UNGROUNDED INV. QTY INV.QTY QTY I DC OPTIMIZED INPUT VOLTAGE VOPT VOLTS (Dc) 350 MODULE QTY. /BRANCH CCT. MODaTY QTY 18 MAX INPUT CURRENT IMAXDC (MODaTY*WDC)/VOPT AMPS (Dc) 15.69 MAX OUTPUT CURRENT IMAXAC (IAC*1.25) AMPS (Ac) 26.25 CONDUCTOR SIZING CALCULATIONS ITEM PARAMETER UNIT CALCULATED LIMIT ITEM NOTE /CALC I) CONDITION OF USE (COU): DETAIL (AMPACITY *TEMP. DERATE *FILL DERATE)vs. REQ'D (IMAX) 2) TERMINALS (TERM): SOLAREDGE AMPACITY AT TERMINALS. vs. REQ'D, (IMAX * 1.25) MAX. SHORT CIRCUIT CURRENT (ISO KEY SIZE CU/AL INSULATION CALC. TYPE AMPACITY (A) W/0 DERATES TEMP. DERATE FILL DERATE RESULT (A) REQ'D (A) NEC 240.4(D) A #14 CU PV WIRE COU 25 0.82 0.80 16.40 15.69 20A II TERM OPTIMIZER SPEC AMPS (DC) 15 20 19.61 B #14 CU THHN/THWN COU 25 1.00 0.80 20.00 15.69 ZOA TERM 20 19.61 C #10 CU THHN/THWN COU 40 1.00 1.00 40.00 21.00 30A TERM 35 26.25 POWER OPTIMIZER SPECS ITEM PARAMETER UNIT CALCULATED LIMIT ITEM NOTE /CALC UNIT DETAIL POWER OPTIMIZER MAKE OPTIMIZER SPEC 8 SOLAREDGE POWER OPTIMIZER MODEL OPTIMIZER SPEC MAX. SHORT CIRCUIT CURRENT (ISO P320 MAX INPUT POWER, (WDC MAX) OPTIMIZER SPEC WATTS (DC) 320 MIN INPUT V, (VDC MIN) OPTIMIZER SPEC VOLTS (Dc) 8 MAX INPUT V, (VDC MAX) OPTIMIZER SPEC VOLTS (DC) 48 MAX SHORT CIRCUIT CURRENT (ISC) OPTIMIZER SPEC AMPS (DC) II MAX OUTPUT CURRENT OPTIMIZER SPEC AMPS (DC) 15 OPTIMIZER EXTREME OPERATING CONDITIONS ITEM PARAMETER UNIT CALCULATED LIMIT 5.490KW MAX. INPUT POWER WATTS (W) 305 320 MIN. INPUT VOLTAGE VOLTS (V) 35 8 MAX. INPUT VOLTAGE VOLTS (V) 46 48 MAX. SHORT CIRCUIT CURRENT (ISO AMPS (A) 10 II MAX. OUTPUT CURRENT AMPS (A) 7 15 MAX. OUTPUT VOLTAGE VOLTS (V) 60* `OPTIMIZER OUTPUT VOLTAGE RANGE BETWEEN 5-60 Voc -STRING VOLTAGE IS REGULATED BY THE INVERTER (NOT TO EXCEED SOOVoc) NOTE: CALCULATED VALUES ARE THE ABSOLUTE MIN/MAX OF ALL ARRAYS USING THIS POWEROPTIMIZER CONFIGURATION -MAXIMUM STRING VOLTAGE IS SOOVoc (INVERTER REGULATED) ARRAY INFORMATION ITEM QTY SYSTEM SIZE 5.490KW ARRAY I TILT 18° ARRAY I AZIMUTH 90° ARRAY 2 TILT 18° ARRAY 2 AZIMUTH 180° ROOF TYPE ASPHALT SHINGLE INSTALL TYPE FLUSH STRING CONFIGURATION STRINGS QTY MODULES OPTIMIZERS STRING I 9 Q.PEAK-G4.1 SOLAREDGE - P320 200 ALLOWED PV PER NEC 305W 40 STRING 2 9 Q.PEAK-G4.1 SOLAREDGE - P320 305W INTERCONNECTION CALCULATIONS ITEM UNIT PANEL BUS RATING AMPS 200 MAIN DISCONNECT AMPS 200 ALLOWED PV PER NEC AMPS 40 PV OCPD DEVICE USED AMPS 30 City of Wheat Ridge ilding 0 1 9'3—ncA # NOISIn3a I # 133HS S(1bv:)Vj 31111 `JMO SIN 31VOS sn-aH00093s loalad-ios (S)a3i2JAANI M909 1'79-W1J'0 VHMNVH 3inaow 81 S31naow Jo # ]viol MN 067' S :3ZIS W31SAS :s3innelallN W3isAs C 0(3 3Idl-10n0l0Hd w� rn D 0 rn c ° o D 43ZIJ213N3 39 Jl`dW (INV z Z o m z 0 0 F rn � F- dli1 JAANI NO a]1V00� mDm m 0j (S)minv�d I 'SaIN18W00 'SN0110Nnf i�V ONVZ`dH MOONS IVOINIO3-13 cu Q n D O JNIN?�tiM O n -W O moo m n m 0 m T o 04 CM l a3NM0 112X0090 L" TOT 3NOHd W07 dV10S31SVWVNDdDmno3eVN 11VW3 a3Mnooev wI)I 3WVN 13V1N00 30 1NI0d 1 ...3(100 WMU0313 IVNOIlbN t WZ 3H1 HlIM Jl1dW00 Ol JN1a2Jt 0V -1d ]IV..,, I ONISnOH 2JI18W Q02Jd Ad �13Y NO ad1V00� OV1 SSV2j8 I :1N3W]dinD3�J /.ir n ONISnOH HIi]W Q0dd Ad T80X NO (MV00� OVl SSVH8 I :1N3W]dinoid Jklrnn ONISnOH HAi]W NO a�11V00-1 (S)(IHVOV-ld I :1N3W]dinD3a ),,inun -1�]NVd OV IaISNI (111V00-1 (S)-1A8V-1 I '75'069 DAN I�MdonS ,INV (INV -1]NVd SNIVW NO a31V00-1 Sa?JVOV1d Z :(t7)(0)ZI'SOL DAN ONiailne laISNI Si�jnSO-13N] 1nd1n0 /imnOS Ad -I�V NO a�I1V00� 1AAd1S dl-1-1�ll 095t7 SIAOV� DAN dAi]W NOiiono0dd Ad GliOINNOO W]1SJ,,S 3I'dl-10A0i0Hd /�iri ln (INV Ad /lO a]d -1AN'dd 10INN00SIa 0V lb' a�I1V00� (S)a?JVOVld I :(Z)(3)'71'069 DIN 10INN00SIa 00 NO a]1V00-1 (S)-il8d-1 I :gS'069 DIN 10INNOOSIa 0a NO (AiV00-1 (S)a6V0V-ld 1 :(Z)(D)tM *069 DAN 10INN00SIa 00 IaISNI a11V00-1 (S)118V-1 I :LI'069 DIN 103NNOOSI4 0(3 3Idl-10n0l0Hd w� NOIIISOd N3dO 3H1 NI a3ZIE)N3N3 38 AVW SMIS GVOI aNV 3NII H1O8 NO SIVNIWN31 SIVNIWN31 HOf10l ION Oa CIMVZVH NOOHS I` OIN10313 JNINNVM 0 a01OVa1N0O w� Z o 43ZIJ213N3 39 Jl`dW (INV il N —1. ` W81SJ.S a1aNnO�IONn a3aNnSIHl o . � , � dli1 JAANI NO a]1V00� • , d0 BaIS 0a NO S10�NN0OSIa AO S210 �f1ON00 34 H101OHd zD� 3 OP (S)minv�d I 'SaIN18W00 'SN0110Nnf i�V ONVZ`dH MOONS IVOINIO3-13 0. caWo- Q 95'069 '(S)ZI'069 DIN , S��eV� (�)S�'069 DIN JNIN?�tiM O n -W . • . X00 Or R p , L (D, SN01iVOIA10 d 9NI19V-1 l a01OVa1N0O SERVICE DISCONNECT OF 2 WARNING: INVERTER OUTPUT CONNECTION DO NOT RELOCATE LABELING SPECIFICATIONS I PLACARD LOCATED AT MAIN SERVICE DISCONNECT NEC 705.12(D)(7): I LABEL LOCATED AT PV BREAKER SERVICE DISCONNECTIPLACARD LOCATED AT FUSED PV AC 2 OF 2 SERVICE DISCONNECT I **ALL PLACARDING TO COMPLY WITH THE 2014 NATIONAL ELECTRICAL CODE** I CONTRAC V 0 0 m Q J N 0 CLQ �0 u �Q y U o POINT OF CONTACT: NAME: KIM ABCOUWER EMAIL KABCOUWER@NAMASTESOLAR.COM PHONE 303.447.0300x21 I OWNER: � ~ O U w 00 0 U 0 M U U Q Q M w �LLJ LLQZ Lu Q Z ry wto00 0 LLQ Z I SYSTEM ATTRIBUTES: I SYSTEM SIZE: 5.490 KW TOTAL # OF MODULES 18 MODULE: HANWHA Q -CELL Q. PEAK -G4.1 505W INVERTER(S): SOLAREDGE SE5000HD-US SCALE: NTS DWG TITLE: PLACARDS SHEET # I REVISION # PV -E.41 0 City of Wheat Ridge 'o > M m E u �Q U # o d m L E � C J m VIA O Z O POINT OF CONTACT: NAME: KIM ABCOUWER EMAIL KABCOUWER@NAMASTESOLAR.COM PHONE 303.447.0300x21 I OWNER: � ~ O U w 00 0 U 0 M U U Q Q M w �LLJ LLQZ Lu Q Z ry wto00 0 LLQ Z I SYSTEM ATTRIBUTES: I SYSTEM SIZE: 5.490 KW TOTAL # OF MODULES 18 MODULE: HANWHA Q -CELL Q. PEAK -G4.1 505W INVERTER(S): SOLAREDGE SE5000HD-US SCALE: NTS DWG TITLE: PLACARDS SHEET # I REVISION # PV -E.41 0 City of Wheat Ridge INSPECTION RECORD Inspection online form: http://www.cl.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Reques an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following busine day PERMIT: ADDRESS: !L5 b '1'' JOB CODE: N, V jo) Foundation Inspections Date Inspector Comments Initials - 102 Caissons / Piers 201 Electrical / Cable/ Conduit 103 Footing / P.E. Letter 202 Sewer Underground Int. 104 Foundation Setback Cert. j''J 105 Stem Walls 106 Foundation wall Insulation 204 Plumbing Underground Int. Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext.s%r/'� 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS sol. PERMIT: AO 00 : �� ADDRESS✓gV 7-Ct&r JOB CODE:KI//�-e� Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 "For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. i CITY OF'WHEAT RIDGE' Building Inspection Division< (303) 234-5933 Inspection line �. (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ;�0352A:A r' Job Address: Z7 ?6 r- e_ I I L-1) f — Permit Number: ❑ No one available for inspection: Time r ) AM/PM Re -Inspection required: Yes 'No , I" _ When corrections have been made, call"for re -inspection at 303-234-5933 Date: /P'/;V7 Inspector:6-1 /4'1"" DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 7_4 Permit Number: 1 p 3 S 9 ❑ No one available for inspection: Times AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: L/ 1 ii Inspector:_ DO NOT REMOVE TMS NOTICE City of Wheat Ridge Residential Sewer Repair PERMIT - 201709479 PERMIT NO: 201709479 ISSUED: 12/07/2017 JOB ADDRESS: 4580 Teller ST EXPIRES: 12/07/2018 JOB DESCRIPTION: 8 x 3 cut in yard; 8 ft of pipe for sewer repair *** CONTACTS *** OWNER (303)425-5117 BABCOCK FAMILY TRUST SUB (720)203-0657 Sam Strand 110231 Pipe X LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: R-3 / Residential SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 1,200.00 FEES Total Valuation 0.00 Use Tax 25.20 Permit Fee 50.30 ** TOTAL ** 75.50 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Sewer Repair PERMIT - 201709479 201709479 4580 Teller 8 x 3 cut in ST ISSUED: 12/07/2017 EXPIRES: 12/07/2018 yard; 8 ft of pipe for sewer repair I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner oft e property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further a est at 1 am le ally authorized to include alI entities named within this document as parties to the work to be performed iid that al woto be performed is disclosed in this document and/or its' accompanying approved plans and specifications. ;Ra+m-e'of OWNER or CONTRACTOR (Circle one) Date This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any, ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of CW heat idge MMUNITy DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: d,1'7 Plan/Permit # 000►►► l / ( ( / Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Property Owner (please print): a�� �c. Co cY� Phone:�- Property Owner Email: Y -T01\ 0 ) 44 Mailing Address: (if different than property address) Address: City, State, Zip: Arch itect/Enaineer: Architect/Engineer E-mail: Contractor: .1 `�p e X LLC Contractors City License #: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # CQ'i � < z .D -e Plumbing: W.R. City License # Phone: Phone: 3 IL--402- C_ L-402_ C Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPNR or REPLACEMENT OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) B� 3 C��- �.'. y GY tAPr1- Sq. FULF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) 110% OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) PRINT NAME: t ZONING COMMMENTS Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS CTOR) r (AUTHORIZED REP ENTATIVE) of (OWNER) (CONTRACTOR) SIGNATURE: DATE: Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation Distdct ❑ Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION Building Division Valuation: $ City of Wheat Ridge Residential Roofing PERMIT - 201703529 PERMIT NO: 201703529 ISSUED: 07/10/2017 JOB ADDRESS: 4580 Teller ST EXPIRES: 07/10/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration TruDef Driftwood asphalt shingles with ROOF DECKING - 37 sq. *** CONTACTS *** OWNER (303)425-5117 BABCOCK FAMILY TRUST SUB (303)922-7663 Chuck Cooper 022034 Kape Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: R-3 / Residential SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 14,800.00 FEES Total Valuation 0.00 Use Tax 310.80 PAID Permit Fee 283.55 Y ** TOTAL ** 594.35 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201703529 PERMIT NO: 201703529 ISSUED: 07/10/2017 JOB ADDRESS: 4580 Teller ST EXPIRES: 07/10/2018 JOB DESCRIPTION: Residential Re—roof to install Owens Corning Duration TruDef Driftwood asphalt shingles with ROOF DECKING — 37 sq. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this pen -nit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be perfonned and that all work to be performed :s disclosed in this document and/or its' accompanying approved plans and specifications. S I% - . f 11 Signature of OWNER oi�J CONTRAOTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying flans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Isuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new pen -nit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a it s qJ1 of be construed to be a permit for, or an approval of, any violation of any provision of any applicable n . rdma c r I ion of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY II.:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will lie'a&e q a ccpteed byemail only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Dan Schultz 7,017035,2-q From: no-reply@ci.wheatridge.co.us - Sent: Monday, June 26, 2017 1:22 PM To: Permits CommDev —� Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Dane Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being processed within 5 business days, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number 4580 Teller St Jeanna Babcock 303-425-5117 Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Kape Roofing Contractor's License 022034 Number (for the City of Wheat Ridge) Contractor Phone 3039227663 Number Contractor Email Address mail@kaperoofing.com Retype Contractor Email mail@kaperoofing.com Address DESCRIPTION OF WORK Are you re -decking the Yes roof? Description of Roofing Owens Corning Duration TruDef Driftwood Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 37 material selected above? Does any portion of the No property include a flat roof? If yes, how many squares Field not completed. on the flat roof? 01 TOTAL SQUARES of all 37 / y roofing material for this project Provide additional detail Tear off to deck, re -roof house with asphalt shingles here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 14800 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Isela Brown Email not displaying correctly? View it in your browser. 3 o Contract Home Office 12096 W 50th Place, Wheat Ridge, CO 80033 Ph 303-922-7663#866-925-5273, Fax 303-762-9006 Colorado Springs, CO 719-475-7663 Salina, KS - 315 W Pacific Ave Ph 785-826-2577, Fax 785-826-2523 Wichita, KS 316-686-7663 Omaha, NE 402-573-7663 Oklahoma 405-340-2727 Customer _�eq/�j(JoL 134h �r'lf Date Address q7-1ler-. ST Billing Address City do, City StateState Zip Home Phone7 Cell Work Phone ❑ Roof Cover/type/style ❑ Color ❑ Remove ❑ Base Felt ❑ Valley -o- F~ ❑ Ridge ❑ Decking ❑ Metal Edge Color ❑ Pipe Flashings ❑ Vents ❑ Stack Caps Missouri 913-287-7663 lEr Clean up and haul off roof debris (Guttel �R )moval & placement L3 -Nail Magnet used around house GIS.- lc C- Protect Landscaping PC ob Insured by KAPE ermit add cost $ �dd ❑ Driveway Inspection .%� / ontractor 10% O&P $ - ❑ Manuf. Ltd. Warranty s. +�' ❑ KAPE workmanship warranty: /y'Fs (Warranty terms apply) —Adl & 71pz- -;- l5 nN a l*ve .s Make Checks Payable to: Kape Roofing & Gutters $ 2c, upon commencement of work (Any payments made prior to commencement will be hold in trust until the materials are delivered and the work begins) $ 64/,*1— (Balance) Upon Completion of Work* INSURANCE ALLOWANCE AGREEMENT Customer authorizes Carrier to pay KAPE directly for all agreed upon work. (Initials) /Approx�imate Date of Service: ' lei TOTAL Price of goods & services *KAPE Roofing & Gutters Inc reserves the right to file for supplemental insurance claims when necessary, which shall become a part of this agreement. KAPE Roofing & Gutters Inc, as the contractor, is entitled to the full O&P provided by the insurance company. Building Owner (s) (Customer) hereby retains Kape Roofing & Gutters, Inc. (KAPE) to repair/replace the roof and/or gutters upon the above stated property, contingent upon KAPE' s receipt of Customer's insurance company (Carrier) approval and payment of said work. Customer understands and agrees that KAPE Roofing & Gutters, Inc. will review said work proposal with Carrier's representative. Work will commence only after KAPE and carrier agree upon the extent of damages and the cost of repairs and replacements. This agreement is for full scope of insurance proceeds not excluding deductible, depreciation, overhead, and profit, therefore CUSTOMER'S OUT OF POCKET EXPENSE WILL BE CUSTOMER'S INSURANCE POLICY DEDUCTIBLE AND ANY NON RECOVERABLE DEPRECIATION for work agreed upon between Carrier and KAPE. AS PER CO LAW S1338, KAPE CANNOT PAY WANE OR REBATE THE DEDUCTIBLE IN PART OR IN WHOLE. Customer agrees to provide all necessary documentation for the claim, and any documentation necessary to facilitate payment from the Carrier or Mortgage Company. Carrier only pays for installed materials. All surplus material is property of KAPE. Replacement of deteriorated siding, decking, fascia board, ventilators, flashing, or other materials is not included and will be charged as extra unless otherwise stated above. Customer may be required to supply all electricity necessary for the work. Lien waiver submitted upon final payments. KAPE is not responsible for interior personal items . All work is to be completed in a workmanlike manner according to standard practices. The Customer hereby acknowledges that KAPE may be subject to delays due to inclement weather or material shortages, which are each beyond the control of KAPE and therefore accepts any delays that may occur by one or all of these circumstances upon completion of said work. Customer grants access to the property as is necessary for the setup and execution of work. Any changes from the above specificatiou5 involving extra costs will be executed only upon written order and will become and extra charge over and above the estimate. WARRANTY TERMS: KAPE Roofing & Gutters, Inc., agrees to repair any defect in workmanship for a period of two (2) years following work completion. KAPE' s liability is limited to its cost to affect any warranty repairs. Warranty does not cover damage to roofs caused by lightning, gale (>50mph), hurricane, tornado, hailstorm, or other violent storm, impact of foreign objects or damage to roofs due to settlement, distortion, failure or cracking of the roof deck, walls, or foundation of building. This WARRANTY is null and void if payment, or any other terms of the contract have not been met. THIS WARRANTY IS NON -TRANSFERABLE. All statements on reverse side apply to contract. Accepted by Insured: Insurance Co.: Kape Rep: Date: eL17/gym :7 Date: Claim #: Date: /'] i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: V_Q I' Job Address: 50L.�,o m-n'Lea '57r Permit Number: ��cD I`i 0 15 1-9 OF ❑ No one available for inspection: TimeU(. MM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303 -234 - Date: r • ,2 . 1-7 Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Roew L.rri.YG Job Address: y_5~'o T87/tf Sr Permit Number: O9 /I52> ❑ No one available for inspection: Time //,17o AM/PM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date: / ,ej/✓7 Inspector: DO NOT REMOVE THIS NOTICE ♦ A s CITY OF WHEAT RIDGE ' Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: �6: Job Address: r^ "s Permit Number: ❑ No one available for inspection: Time AM Re- Inspection required: Yes No When corrections have been made, call for re- inspection at 303-234-5933 f ' Date: /D Inspector: DO NOT REMOVE THIS NOT /CE _;�o 4�a;F 61 0 <? 5 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line ]~;Ir(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Fivat keg~l- Job Address: rV5S?D T ~tt/2 5 i Permit Number:/15h ry ,~1Ll?~G 70/e 7 f1tf/sJ ~r T' r~~ T Yx {3 .r~fi"l~ c iz 1-1.2 1/'✓5_P,1512 7ieJ x'1.1 e~lilf*. S~sr/s7 ~z7 t7"-_ / $ 773 L✓.~'+i.G,k~ d nl ❑ No one available for inspection: Time 91'fL M Re-Inspection required: Yes _No *When corrections have been made, call for re-inspection at 303-234-5933 Dater IZV11.9 Inspector. DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 235 -2857 Fax INSPECTION NOTICE Inspection Type: i ,'LO iJcz' Job Address: 7 �f/�. f" Permit Number- aalz "O ❑ No one available for inspectio�Time '•YLJ AMIPM ) Re- Inspection required: Yes When corrections have been made, call f r re- in at 30 (f 3 i' -- 23 34 4 4 - - 5 _ 933 ft Date: •0- Inspector: i ;. 1R� DO NOT REMOVE THIS NOTICE City of Wheat Ridge Building Division 4 , m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 °otoRno° Inspection Line: 303-234-5933 Building Permit Application Date: Plan Permit a l~ Property Owner (please print): 45?io lp_, ,L Phone: 303 z5 5ll Mailing Address: (if different than property address) Address: St City, State, Zip; fit} t ~doF'3 3 ILYMM: 1/1"x Contractor Licensem ~g$ Phone: &63-425-`Z53 Electrical City License Company: Plumbing City License Company Mechanical City License Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of s ace descri tion): AJJ_ kA_ta~ construction value: s 15~a. (J-Z) 41 1 (as calculated per the Building Valuation Data sheet) Q.r,t= £ dll Ian Review (due at time of submittal): $ ,UJr' #'b Sq. Ft./L.Ft added: Squares 30 BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements -shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that *1 -assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field Inspection, CIRLCEONE:: (OWNER) CONTRACTOR) PERSONAL REPRESENTATIVE of (OWN,E,R)• ,(CONTRATOR) PRINT NAME: SIGNATURE: OA±±~,yv- Date: OF/.✓~/ D ~ a w 0 ~ z w a 0 -i W ~ W ~ H Z ~ ~ ~ O U c 0 .N 0 N d Z d CO) ~ 0 r c~ d Q 0 c N N co N N M N M O M ~ t~ r. L•. II 0 W L L 1-•~~ . U O N N N ~ 9 'O Q d O n ~ ~ 0 ~ d a N C ~ w R V N ~ m E c a(Di -0 a) > m L N C O U N ~ ~ U C N t M M OI N a M NI M O M 3: w N ~ COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number Date 77252 6/21 /2004 Property Owner: JEANNE BABCOCK Property Address : 4580 TELLER ST Contractor License No. : 19669 Company : Rauh Brothers Phone : 425-5117 Phone : 932-8184 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheal Ridge Building Code (U.B.C.) and all other applicable Wh at Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED, ~ DATE L 40 Description : 1 STORY ROOM ADDITION (480 SQ. FT.) Construction Value : $82,187.00 Permit Fee : $1,137.25 Plan Review Fee : $739.21 Use Tax : $986.24 Total: $2,862.70 Use : /L)C. .l---- . ~ 4v•-7 0 Please Note: Aiwmnl'•,ntractoriSresAOns~n~~ BUILDING DEPARTMENT ~18B~E4mw°t~°~ '`?T° n~ apmoved pla i i TC Sq: Ft 480 Zoniryg CommenCS:; The City is no, Approval : JH 6121/04 Zoning . R-2 f t~ ~ 6ullding Coritments:' ADDITION COMMENTS ON PLANS. 6121104. NEED SE . , AND Approval : CR WATER LAY OUT ON SITE PLAN-THEN OKAY TO ISSUE. Public WorKS Comlments€„ Approval : Occupancy : R-3 Walls : 2X6 Roof : Stories : Residential Units : Electrical License No : 18958 Company : Edgewater Electric Expiration Date : 2/28/2005 Approval : OKIKS Plumbing License No :22007 Company :Piney Creek Plumbing Inc. Expiration Date : 6/22/2005 Approval: ok/ks Mechanical License No : 22009 Company : E& M Heating & Air Conditioning Inc. Expiration Date : 6/2312005 Approval: oklks (1) This permit was issued in acwrdance with the provisions set foAh in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Cotle of W heat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work aulhorized is nol commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a periotl of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount nortnally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonmeN has not exceeded one (1) year. It changes are made or if suspension or abandonment exceeds one (1) year, fu0 fees shall be paid for a new permit. (4) No work of any manner shali be done that will change the natural flow o( water causing a drainage problem. (5) Contrdctor shall nolify the Building Inspector hventy-four (24) hours in advance (or all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) The i of a pemfifo_~ie al of drewings and specifcalions shall not be conslrued lo be a permit for, nor an approval of, any violation of the of 6uilding code ther ordinance, law, mle or regulation. G~j%1a6M Chief Building Inspector Please sign Terms and Conditions on reverse side of page. COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: o~ W"E",~ BUILDING INSPECTION LINE • 303-234-5933 Date: ~ ~ CITY OF WHEAT RIDGE ° 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) `°`°R"°° APPLICATION PropertyOwner: Property Address: ~(f... 57 7-. Connactor License No.: Company: 94-0q Phone: 3e) 3"4,1 a 5 _ S/ I'? C~ 0-7 7- lbCl Phone: 30 3 93a NlffX G GREEMENT AND A OWNER/CONTRALTOR SIGNA7URE OF UNDERSTANDIN Construction Value:0~, 187 I hereby certify that the setback distances proposed by this permit application are IIriIt F C:Q P accurate, and do not violate applicable ordinances, rules or regulations of the City of O C WheatRidgeorcovenants,easementsorresUictionsofrecord;thatallmeasurements Plan ReV1CW FCO:$ shown, antl allegations made are accurate; that I have read and agree to abitle by all conditions printed on this application and that I assume full responsibility for [JSe T2X'R compliance wilh the Wheat Ridge Building Code (U.B.C) and all other applicable thi it Y $ T l s pertn . Wheat Ridge Ordinances, for wor under 3 : O A, DATE (OWNER)(GONTRAGTOR)'.SI6NED L . (OWNER)(CONTR4CTOR):PRINTED --~~XY I`^''toil-f Description: I 5-Fe 2~/ JL(o 0 v,., *2~ ip JJ / 7-7 b v.J Sq. Ft. added 419 D BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: COMMENTS: 6I Z I'O ~ Approval: Zoning: GCOMMENTS: A~^ ~t~,ep~ ~',pVy1►y~~ 0I4 Approval: fs Cif,~~ Aked SCu~41 6nS 4Nd w`41~.e. s,k Piii ►~H aE Am W ORKS COMMENTS: ; SSu ` . Approval: t 3 WaIIs:21(e Roof: Stories: Residential Units: Electrical License No: ~ v~~✓~ Plumbing License No: Mechanical License No: Company: tCf_c ~-•o Company:area FlMt, Company: zz-.y,~/lq f_f,fJ Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This permit was issued in accordance with the provisions set forth in your applicalion and is subjeM lo the laws of the State of Colorado and to the Zoning Regulalions and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the Ciry. (2) This permit shall expire if (A) the work authorized is not commenced within sixty(60) days from issue da[e or (B) the building f i d f 120 d ays. o o aulhorized is suspended or abandoned or a Per (3) If this permit expires, a new permit may be acquired tor a fee of one-half the amount normally required, providetl no changes ~ have been or will be matle in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No woAc ot any manner shall be done ihat will change the natural Flow of water causing a drainage problem. (5) Coniraclor shall notify the Building Inspector lwenty-fwr (24) hours in advance for all inspections and shall receive wririen approval on inspection cartl before proceeding with successive phases of the job. (6) The issuance oi a permit or the approval of drawings and specifica6ons shall not be construed to be a pertnit (or, nor an approval o(, any violation of the provisions of the buiitling codes or any other ordinance, law, rule or regulation. ~ Building Official