HomeMy WebLinkAbout3244 Taft Courti CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type:, Job Address: Permit Number: ❑ No one available for inspection: Time ( ]W/PM Re -Inspection required: Yes NQ_-- / When corrections have been made, shea ection online at. http //www.ci.wheatridge.co.uslnspec on, Z '�` D e' In r,Yert r- CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: zA4F1 ^/ Job Address: �- Permit Number: 3�- i v � ❑ No one available for inspection: Time A Re -Inspection required: Yes When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. uslinspection Date: -6,6 _ Inspector: DO NOT REMOVE THIS NOTICE CA - J2.26 ENGINEERING 19 February 2020 Chelsea DeFelice Creative Badass, Interior Architect Keystone Consulting chelsea(&kevstoneconsulting.me (303) 570-4936 Dan Canda, P.E. J2.26 Engineering 6937 W 83rd Way Arvada, CO 80003 dcanda@i226eneineerine.com (720) 937-2055 RE: Structural review of remodel at 3244 Taft Court J2.26 Project M 20026 Chelsea, At your request, on behalf of the homeowners, I arrived at 3244 Taft Court to review and comment on the plumbing penetrations through the existing floor joists. I understand that the size and location of the penetrations caused concern regarding the structural integrity of the joists. Each joist that has a large plumbing penetration has one or two Simpson MSTA 36 steel straps installed with (10)- 10d nails on each side of the penetration, ((20) 10d nails total minimum). Based on my observations, the plumbing penetrations with the steel strap reinforcement of each joist is appropriate to meet or exceed all required structural loading and meet all local code requirements. The seal below confirms that the observations and considerations associated with this project were completed by me, or under my direct supervision. Please feel free to contact me if you have any additional questions regarding this report. Re a�--'CLP0 Lice, Q �N V IV O �, Digitally signed by Daniel M. /►.r 4' ` Q Canda DN:. E E�Icanda 2.26en Ineerin com, 0047958D 1 el M. Canda 0=J2.26 @gineering, g r OU=President, CN=Daniel M. Daniel M. Canda, P.E. Rea son: I am the author of this President ,�,nda ,� �4, — document Date: 2020.02.21 08:36:25-07'00' J2.26 Engineering, LLC FSS�DNAL ENS\ 6937 W 83rd Way, Arvada, CO 80003 - www.0226engineering.com - 720.937.2055 Page 1 of 1 i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number:�%'"Z-? 1 ❑ No one available for inspectio .: AN Re -inspection required: Yes-. N p q ° When corrections have been made, scfiedu el for re -inspection online at: hUp✓/www.ci. wheatridge. co. usrinspection Date:' �.",, Inspector:��'"`� DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE r--) ti Inspection Type: - _ Job Address: G Viio f f Permit Number: -)- u u O 1_� Z.. ❑ No one available for inspection: Time �F'� AM/PM Re -Inspection required: Yes No a When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. uslinspection Date: 6 " Lv Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address:,`-!'- Permit Number: V ❑ No one available for inspection: Time��'J'� AM/PM Re -Inspection required: Yee No When corrections have been made, schedule for re -inspection online at: http://www. ci. wheatridge.co. ushnspection Date: Inspector: ®O NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division r' (303) 235-2855 Office INSPECTION NOTICE Inspection Type: 19 � �- _0 CC Q- Q !o 1,�, _� VMt_c �-, Job Address: _�iD C Permit Number: �L �11 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http://www. ci. wheatridge. co. uslinspection Date: J'd r , ,) c, Inspector: --1 DO NOT REMOVE THIS NOTICE LA) L? -363 7.1 ; jto' r' : f•�'� � CUMML , 1% 1.LOPA4ENT : 9—Dito�-k "2-: Jai ya- — ; APP'Ki2:VEP iGI.M I i,(o`fi Reuiewed for'Code Lori fiance Date' �. - . ; n- i�! or'a0➢cOv61 o�Oldns SOK1fKalgNS ' f 1 '' �yV.};�.�. f f f , .The but)d,ngcoQFofofony C)tyordkvXes.pcn"f!•� 1 f fi�Tim '� R 5&n�c NT {,�R 1 --� > ty to Violate of cothe Otovisim o/fhe 6WfdkV f "Jes or -:'+o• old; � ce5 of fhE City Sholl not be vo,%d , ; ; n J; ;'fiiS c2Ay r; N 6jk�S S- 7 g -7: (,off `i,d'4"— .yam {� �i �S' Bin 'iii-(}��K 1�? Gn e455: +7 I i i3f,)is Ito so i TA- IZi sz Lil..i✓y(t1 0✓t �j�-1� i( t�fY A/ti 144r,/1s4-cw t f.�. ��1 A'! � tic., 1 � � (,� �1 �i'�19- l isi+•l.� fT't� Lo4li Scale: 1 square = / &;,exeAKL— .a r -- - -- --AD- m ; ; ,- -, ° a < e St ; N .a -, e °' •p; l�• g j ti' C 1 I A Qi T Ti v r r r r r a � � r w r Scale: 1 square = i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: .. t.. - Job Address: - t 4= '77 Permit Number: ('7 ❑ No one available for inspection: Tim Re -Inspection required: Ye "` No ) When corrections have been made, schedule for re -inspection online at: httpYAvww. ci. wheatridge. co. uslinspsctioi} �t- i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: lz? 1 vny, m e LL-, PJ. 12 or.. Job Address: L I{ C�_ Permit Number: c , l � j rv- _ a A_ .1... ....n _ i �✓�1 a _ ��C 1 le�rW� c s �v tVelc� . tt 1 -err e t _ r P r? \ A ` c Ct mac; fr c c C 1 k".\\ V -N 41 C +- e ❑ No one available for inspection: Time AM/PM ., Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge-co, usfinspection Date: 13', ° t� Inspector: DO NOT REMOVE THIS NOTICE City of Wheatj�dge COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Mechanical Subcontractor This form must be completed & signed by the MECHANICAL SUBCONTRACTOR performing mechanical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: General Contracl �w FORM WILL NOT RE ACCEPTED WIT_ISSINO INFORMATION Company Name: ' S LLLContact Phone #: &-3 ' O�U �} T2C Wheat Ridge Contractor License #: Printed Name of Authorized Agent Signature of Authorized Agent �-IU '14A,*6 (required field) 11 2-(� 1�b2fJ Date City of Wheat Ridge Residential Remodel PERMIT - 202000132 PERMIT NO: 202000132 ISSUED: 01/30/2020 JOB ADDRESS: 3244 Taft Ct EXPIRES: 01/29/2021 JOB DESCRIPTION: Remodel of entire home after water damage occurred throughout home. Electrical, mechanical, plumbing upgrade. Square footage: 9,624 *** CONTACTS *** OWNER (303)304-6049 KUNTZ DAVID A GC (303)807-9332 DARYL OVERHOLT 202009 COLORADO CUSTOM KITCHEN & BATH SUB (303)579-5691 JAY GRUNDBERG 170015 WIRED UP ELECTRICAL DESIGN LLC SUB (303)204-8924 NATHAN CONN 080166 CONN -ECT PLUMBING SUB (303)868-0421 LUCAS WATHIER 140298 MIKE'S HEATING LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 150,000.00 FEES Total Valuation 0.00 Plan Review Fee 945.46 Use Tax 3,150.00 Permit Fee 1,454.55 ** TOTAL ** 5,550.01 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. City of Wheat Ridge a Residential Remodel PERMIT - 202000132 PERMIT NO: 202000132 ISSUED: 01/30/2020 JOB ADDRESS: 3244 Taft Ct EXPIRES: 01/29/2021 JOB DESCRIPTION: Remodel of entire home after water damage occurred throughout home. Electrical, mechanical, plumbing upgrade. Square footage: 9, 624 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpennit fee. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior andspecific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable cod=rFany ordinanc i r regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of ](�jq-rWh6at1kogie COMMUN[TY DEVELOPMENT Building & Inspection Services 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a-)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: 6//A Z 9 - - o Plan/Permit # Plan Review Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3244 Taft Ct, Wheat Ridge, CO 80033 Property Owner (please print): David & Michele Kuntz Phone: 303-304-6049 Property Owner Email: davidkuntz0l@gmail.com Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer: Keystone Consulting - Chelsea DeFelice Architect/Engineer E-mail: chel sea@keystcneconsulting . me Phone: 303-570-4936 Contractor Name: Colorado Custom Kitchen and Bath Inc. City of Wheat Ridge License #: 202009 Phone: 303-807-9332 daryl@coloradocustomkitchens.com Contractor E-mail Address: For Plan Review Questions & Comments (please print): CONTACT NAME (please print): Daryl Overholt Phone: 303-807-9332 1 CONTACT EMAIL(p/ease print): daryl@coloradocustomkitchens.com 7 1 r I� T (D rYl 2�G�-}1�� Sub Contractors (Must provide Wheat Ridge License No aigned Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields, if applicable. ❑COMMERCIAL [ X I RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. A toilet water supply line broke in my house and has caused substantial damage to the flooring and drywall. 9,624 SF Walls, 3.257 SF Ceiling, and 3,159 SF Floors were affected by the flood. The kitchen, bathrooms, and basement are being renovated to restore the home to original condition. The uses of the rooms will remain the same. The furnace will also be replaced as part of the project. An estimate of cost from our contractor is attached with additional details on what work will be performed under this permit. Sq. FULF BTUs Gallons Amps Squares For Solar: KW # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) Ofd a $ Per Colorado Custom Kitchen and Bath estimated project cost is -*NN0PJ1qW- OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application: that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE:OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) SiEnature (first and last name): �` DATE: D / I b zc,2.6 Printed Name: David A. Kuntz ZONING COMMMENTS: Reviewer: BUILDING DEP ENTCOMME TS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: City of Wh6atP,* d COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Plumbing Subcontractor This form must be completed & signed by the PLUMBING SUBCONTRACTOR perfonning plumbing work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: )� �l �T �� �'T General Contractor: 1a, ,eye Oyez k t Co loi'c�d Company Name: cor)ri-eJ Pkmbl 'l� LGe Contact Phone #• Wheat Ridge Contractor License #: D f �� (required field) State License #: % 7/ 7 Master License #: / W Sx Printed Name of Authorized ent o;7°%`.W d Sig ture of Auth ized Agent Date C't f �.ny v. Wh6a:tl�dge ' COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Electrical Subcontractor This form must be completed & signed by the ELECTRICAL SUBCONTRACTOR performing electrical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: _-3pc LN 7014+ C - General Contractor: COI&t% o0 XAChe" CMA B=16 InC - 1701 MGM in ou"On'.] Wool 01 W11-1XIVA trollm-M luella 2[s) Q94i9h � U -C Company Name: W%r`Qc�c�Pir�C 0 Contact Phone#: 3o3'S7q—siO9 Wheat Ridge Contractor License #: 1"+601S (required field) State License #: EC _ 011430 6712 Master License #: IME. 010 ex0'489 Q C- rut-Aloerci PrinteiVName of Authoilded Agent 1-207-2020 Signature of Auffiorized Agent Date Scanned by CamScanner /-/4 . zazo #,,Ioao 00/3 z. 1.....&K Environmental Inc 1 ASBESTOS INSPECTION AND BULK SAMPLING REPORT Created For: Lupe Avalos ServiceMaster Fire and Water Restoration 3250 S. Zuni St. Englewood, CO 80110 Project Name: David Kuntz 3244 Taft Ct. Wheat Ridge, CO 80083 Travelers Insurance Claim# ICK8150 Prepared By: Jeff Mackey L&K Environmental Inc. Building Inspector# 13892 I No AS&C-Mi' ROW - W1 Purpose of Inspection: On July 1, 2019 L&K Environmental had been contracted to perform a limited asbestos inspection and bulk sampling for suspect asbestos containing building material (ACBM). f the amount of ACM to be disturbed exceeds the following trigger levels, then an asbestos abatement contractor must remove the material: Single -Family Residential Dwellings ("SFRD") - the trigger levels are: 50 linear feet on pipes; 32 square feet on other surfaces; or the volume equivalent of a 55 -gallon drum. Public and Commercial Buildings (other than SFRDs) - the trigger levels are: 260 linear feet on pipes; 160 square feet on other surfaces; or the volume equivalent of a 55 -gallon drum. The purpose is to identify possible ACBM that is to be disturbed, determine the condition of suspect materials, and determine homogeneous areas where suspect materials are being tested. When sampling surfacing material, at least three samples must be collected for <1,OOOsq. ft., at least five samples for between 1,000 - S,OOOsq. ft., and at least seven samples for >S,OOOsq. ft. When selecting sample locations, random sampling is done in accordance with the EPA pink book. Once samples have been collected they must be submitted for analysis. Exclusions: 1. A certified building inspector shall not be required to perform an inspection if based on prior records there has been sampling done and determined no ACM is present. 2. An architect or project engineer who was responsible for the construction of the building signs a statement stating that no ACM was used in any known building material. Laboratory Protocol: All bulk samples will be submitted to an independent NIST accredited NVLAP laboratory. Phase Light Microscopy will be used to analyze samples. All samples <1% will be point counted to determine exact asbestos composition. For each homogenous area samples containing <1% asbestos is considered not to contain asbestos if all samples collected show asbestos in this amount. If any samples within a homogeneous area are found to contain >1% the whole homogeneous area must be treated as asbestos containing. Lab Summary for Samples Collected on July 1, 2019: HA # Sample ID Material Description Sample Location Material Affected Friable Asbestos Classification Category 2 Upstairs Master Bath Walls #7 — Any remaining friable ACM or friable suspected ACM. Classification HA in SF (Yes/No) I Content Basement Bedroom Walls SM 1-1 Paint, Texture, Upstairs Master Surfacing 15 Yes ND 1 Drywall Bath Wall, N SM 1-2 Paint, Texture, Upstairs Master Surfacing 15 Yes ND Drywall Bath Wall, NW SM 1-3 Paint, Texture, Upstairs Master Surfacing 15 Yes ND Drywall Bath Wall, NE HA # Sample ID Material Description Sample Location Material Affected friable Asbestos Classification HA in SF (Yes/No) Content 2 MM 1-1 Joint Compound, Upstairs Master Misc. 20 Yes ND Drywall Bath Wall, NW HA # Sample ID Material Description Sample Location Material Affected Friable Asbestos Classification HA in SF (Yes/No) - Content SM 2-1 Paint, Texture, Basement Surfacing 20 Yes ND 3 Drywall Bedroom Wall SM 2-2 Paint, Texture, Basement Surfacing 20 Yes ND Drywall Bedroom Wall SM 2-3 Paint, Texture, Basement Surfacing 20 Yes ND Drywall Bedroom Wall HA # Sample ID Material Description Sample Location Material Affected Friable Asbestos Classification HA in SF (Yes/No) Content 4 MM 2-1 Joint Compound, Basement Misc. 20 Yes ND Drywall Bedroom Wall Summary of Areas Included in HA & Classification Categories: HA # Included in HA Classification Category 1 Upstairs Master Bath Walls #7 — Any remaining friable ACM or friable suspected ACM. HA # Included in HA Classification Category 2 Upstairs Master Bath Walls #7 — Any remaining friable ACM or friable suspected ACM. HA # Included in HA Classification Category 3 Basement Bedroom Walls #7 — Any remaining friable ACM or friable suspected ACM. HA # Included in HA Classification Category 4 Basement Bedroom Walls #7 — Any remaining friable ACM or friable suspected ACM. Recommendations: All samples referenced above were collected on July 1, 2019. The materials/areas sampled on July 1, 2019 contained no asbestos. Removal of the suspect materials/areas may be done without abatement activities. Signatory: Attached is the laboratory analysis report and technician certification (s). Please direct any questions or concerns regarding the information in this report to our office at 303-912-5016 and we will be happy to assist. Thank you for choosing L&K Environmental, Inc. Sincerely, Kevin Mackey L&K Environmental, Inc. Building Inspector# 13984 Attachments: Laboratory Analytical Data; Technician Certifications) 8985 E. Nichols Avenue, Suite 350 Centennial, CO 80112 kT Phone +1 303 799 6100 Fax +1303 799 3441 www.atcgroupservices.com PLM REPORT SUMMARY NVLAP Lab Code 102031 Customer: AIHA Lab Code 101536 Kevin Mackey ATC Job No.: L&K Environmental Batch No.: 0028733 9851 Castle Ridge Circle Report Date: 07/02/2019 Highlands Ranch CO 80129 Sample Date: 07/02/2019 Project: Kuntz/ 3244 Taft Court Date Analyzed: 07/02/2019 Customer Project No.: Identification: N/A Test Method: 600/R-93/116 Page 1 of 2 Client No. Lab No. Sample Description / Location Asbestos Content SM 1-1 0028733-001 LAYER 1 None Detected Paint/Texture, White Note: Layer is mainly Paint Upstairs, Master Bath, Walls SM 1-1 0028733-001 LAYER 2 None Detected Drywall, Brown/White, 23°C Upstairs, Master Bath, Walls SM 1-2 0028733-002 LAYER 1 None Detected White/Texture, White, 25°C Upstairs, Master Bath, Walls SM 1-2 0028733-002 LAYER 2 None Detected Drywall, White/ Brown Upstairs, Master Bath, Walls SM 1-3 0028733-003 LAYER 1 None Detected White/Texture, White, 25°C Upstairs, Master Bath, Walls SM 1-3 0028733-003 LAYER 2 None Detected Drywall, White/ Brown Upstairs, Master Bath, Walls MM 1-1 0028733-004 Paint/Joint Compound, White, 25°C None Detected Note: No Drywall Present Upstairs, Master Bath, Walls SM 2-1 0028733-005 LAYER 1 None Detected Paint/Texture, White, 24°C Basement, Bedroom, Ceiling These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. Drywall, Brown/Gray Basement, Bedroom, Ceiling These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 8985 E. Nichols Avenue, Suite 350 Centennial, CO 80112 NkT C Phone +1 303 799 6100 +1303 799 3441 JffFax www.atcgroupservices.com PLM REPORT SUMMARY NVLAP Lab Code 102031 Customer: AI HA Lab Code 101536 Kevin Mackey ATC Job No.: L&K Environmental Batch No.: 0028733 9851 Castle Ridge Circle Report Date: 07/02/2019 Highlands Ranch CO 80129 Sample Date: 07/02/2019 Project: Kuntz/ 3244 Taft Court Date Analyzed: 07/02/2019 Customer Project No.: Identification: N/A Test Method: 600/R-93/116 Page 2 of 2 Client No. Lab No. Sample Description / Location Asbestos Content SM 2-1 0028733-005 LAYER 2 None Detected Drywall, Brown/Off White, 23°C Basement, Bedroom, Ceiling SM 2-2 0028733-006 Paint/Texture, White, 25°C None Detected Note: No Drywall Present Basement, Bedroom, Ceiling SM 2-3 0028733-007 Paint/Texture, White, 25°C None Detected Note: No Drywall Present Basement, Bedroom, Ceiling MM 2-1 0028733-008 LAYER 1 None Detected Paint/Texture, White, 25°C Basement, Bedroom, Ceiling MM 2-1 0028733-008 LAYER 2 None Detected Drywall Tape, Beige, 23°C Basement, Bedroom, Ceiling MM 2-1 0028733-008 LAYER 3 None Detected Joint Compound, White, 23°C Basement, Bedroom, Ceiling MM 2-1 0028733-008 LAYER 4 None Detected Drywall, Brown/Gray Basement, Bedroom, Ceiling These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 3TC Customer: Kevin Mackey L&K Environmental 9851 Castle Ridge Circle PLM REPORT SUMMARY Highlands Ranch CO 80129 Project: Kuntz/ 3244 Taft Court Customer Project No.: Identification: N/A Test Method: 600/R-93/116 ATC Job No.: Batch No.: 0028733 Report Date: 07/02/2019 Sample Date: 07/02/2019 Date Analyzed: 07/02/2019 8985 E. Nichols Avenue, Suite 350 Centennial, CO 80112 Phone +1303 799 6100 Fax +1303 799 3441 www.atcgroupservices.com NVLAP Lab Code 102031 Al HA Lab Code 101536 Page 1 of 1 PLM Analysis Methodology PLM samples were analyzed utilizing the Environmental Protection Agency's Test Method: Method for the Determination of Asbestos in Building Materials (EPA 600/R-93/116. July, 1993) 40 CFR, Part 763, Appendix E to Subpart E. Reporting Limit <1 % Asbestos. Additional treatment and tests may be required to accurately define composition (i.e. ashing, extractions, acetone treatment, and TEM). Unused portions of samples are archived for one year unless client requests special handling. Asbestos content of mastic/adhesive is separated from total percent asbestos and other materials. Laboratory Equipment Laboratory analysis was accomplished utilizing an Olympus BH -2 polarized light microscope. The microscope is equipped with dispersion staining lenses. Quality Control ATC Group Services is accredited by NVLAP Bulk Asbestos Sample Quality Assurance Program (Lab Code 102031). ATC participates in the NVLAP Bulk Asbestos Sample Quality Assurance Program and maintains an in-house QC/QA program for bulk samples whereby 10% of all submitted samples are reanalyzed and documented in a Quality Control Manual. ATC also participates in a quarterly round robin QC/QA program for bulk samples with several accredited laboratories throughout the United States. Current and past QC/QA program results are available in the laboratory for inspection. Laboratory Personnel Samples were analyzed by Jeff Lomme, Laboratory Director. Mr. Lomme is a professional geologist who has successfully completed the McCrone Institutes's "Advanced Asbestos Identification" Course. Approved Signatory: ,deff Lomme f NVLAP LAB CODE 102031-0 The non -detection of asbestos fibers in floor tile by PLM is of itself inconclusive. Confirmation by Transmission Electron Microscope (TEM) is recommended for negative floor the samples. This report must not be used by the client to claim product endorsements by NVLAP or an agency of the U.S. government. This test reports only to the items stated. �� Cardno� ATC Shaping the Future PROJECT INFORMATION Turnaround: 8985 East Nichols Avenue, Suite 350 Centennial, Colorado 80112 www.cardnoatc.com TEL: 303.799.6100 FAX: 303.799.3441 24 hour 3-5 day Company/Customer: L&K Environmental Project Name: k",+s,1 t Address: 9851 Castle Ridge Cir Collection Date: 9- ' Address: Highlands Ranch, CO 80129 Customer Number/P.O.: Phone/Fax: 303-912-5016 Collection Address: Customer Contact: Kevin Mackey LKEnvironmental@gmail.com Special Instructions: BULK SAMPLE LOCATION Acc/ Sample Number Rej Sample Material Sample Location &MAR.'. A LC- " r rl � tz (� ,� Yui kJ,A kl l- fyt t — --ykW+ . evo cm. yon+'`- 1 Note: Sample collector is responsible for ensuring that all samples have been preserved and prepared to the appropriate and applicable methodology. If package has sustained damage during transit, notify collector and shipper. Turnaround time begins upon receipt of sample (s) by laboratory. Cardno ATC will not be responsible for errors or omissions in calculations from inaccuracy of original data. CHAIN OF CUSTODY &MAR.'. KEYSTONE CONSULTING CRAWL 5PAGE BA5EMENT FLOOR A5 BUILT 5CALE: 1/b" = V-0" City of ' COW heat �dge MMUNITY DtvELOPMENT APPROVED Reviewed for Code Compliance P77AAAA1 I'A'A Z 2� 'FPiansjtXa Iner Date Vallittity of permit: Thr issuance of o permit or approval of pons speaftwiriont and computations shoN rat be o permit fv , or an opprovat of any violation to any of the provisions of the building code or of ori City Ordinances. Permits G RAW L Presuming to give outhorlty to V10100 of Cancel the provia" of the Ndfoag COM or other ordinonorr of the City $holt not be wild 5PAGE C-� l / I'j r %- WLI k -, /L L,0.e4 po r4--aA't 04 /1(r G>/i 6" C� "i ALL PLAN5 A55UME ALL DEMO HA5 BEEN COMPLETED AND IN5PEGTED BY A LIGEN5ED CONTRACTOR ALL PLAN5 HAVE BEEN PROVIDED BY THE HOME OWNER THESE DRAWING5 ARE A CONCEPTUAL REPRESENTATION. ALL DIMEN51ON5 AND 5PEGIFIGATION5 DO NEED TO BE VERIFIED AND CONFIRMED BY LIGEN5ED GONTRAGTOR5 FOR ALL TRADES. a z F z ,,0. U W z o r W Y DATE R VI I i2..19 NOTE5 .19.20 IFINAL. NOTE m m LU o 0 W V C1 W Q LU W~o N'tR z m Q LU �[ _ These drawings and specifications are the property and copyright of Keystone Consulting, LLC and shall not be used on any other work except by agreement with Keystone Consulting, LLC,. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLC prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, Ll -r, accepts no responsibility for measurements and use of the plan by others. DRAYVING5 PROVIDED BY: Chelsea DeFelice DATE: 1/14/20 SCALE: I SHEET: FP 1.1 accepts no responsibility for measurements and use of the plan by others. DRAININ65 PROVIDED BY: Chelsea DeFelice DATE: 1/14/20 SCALE: SHEET: FP 1.2 z Z NORTH z \ pool,V KEYSTONE CONSULTING 38'-b" \ Z O rn w ]C VI N DATE E5GRIFTION 12.6.19 INCTE5 1.13.20 IFINAL NOTE 5UN m m w o v o wv� Q� LU v �~o m P2 zm� BIG ROOM � w �L = These drawings and specifications are the +' Q - property and copyright of ++ Keystone Consulting, LLC and shall not be used on any other work Q� except by agreement Q with Keystone ~ LIVING Consulting, LLC,. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be STUDY brought to the notice of GARAGE Keystone Consulting, LLC prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLC LIVING AREA 2317 SQ FT P�5 BUILT CWheat i MAIN FLOOR A�5 BUILT 5GALE: 11F = V-0" accepts no responsibility for measurements and use of the plan by others. DRAININ65 PROVIDED BY: Chelsea DeFelice DATE: 1/14/20 SCALE: SHEET: FP 1.2 accepts no responsibility for measurements and use of the plan by others. DRAWINGS PROVIDED BY: Chelsea DeFelice DATE: 1/14/20 z z NORTH z O KEYSTONE CONSULTING W z O N Y W Y 16'-13/4"— REV15ION5 2'-4 3/4" 9'-8 3/6" 1�. .19 NOTES 1.13.20 I FINAL NOTE P-3 3/4" 6-1 1/4" O m m wco w o v o BATH GREAT O o Qv0 fr ROOM 91 �^ BATH o a's �Qu.i BELOW � �~Q 6'-3 5/8" CORNER OF zm� BEDROOM EXTENDS 7 INTO GREAT ROOM D W CEILING PIC Y These drawings and Q specifications are the MASTER property and copyright of BED 2 Keystone Consulting, GARAGE BED 1 LLC and shall not be used on any other work BELOW except by agreement with Keystone Consulting, LLC. Written dimensions shall not take preference over scaled GORNER OF dimensions and shall be BEDROOM EXTENDS INTO GARAGE verified on the job site. CEILING Any discrepancy shall be brought to the notice of Keystone Consulting, LLG prior to the commencement of any LIVING AREA work. Any item not on 11%5QFT A5 BUILT this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLC SCALE: I CWheat SHEET: UPSTAIR5 A5 BUILT FP 1.3 5GALE: 11b" = V-0" accepts no responsibility for measurements and use of the plan by others. DRAWINGS PROVIDED BY: Chelsea DeFelice DATE: 1/14/20 N KEYSTONE CONSULTING CONSTRUCTION NOTES G1 ALL DIMEN510N5 ARE TO BE 51TE VERIFIED G2 FLOOR PLAN TO REMAIN A515, ALL EXTERIOR WINDOWS TO REMAIN A515 03 FLOORING ALL TO BE LVP. M015TER BARRIER, NO ADDITIONAL UNDERLAYMENT G4 ALL OTHER ITEMS ARE TO REMAIN A515 G5 ADD WALL IN FRONT OF 5TORAGE, SEE FRAMING PLAN, NEW DOOR 5EE DOOR 5GHEDULE G6 ALL DOORS TO BE NEW, WHITE, 6 PANEL, SEE DOOR SCHEDULE C7 TRIM TO BE MDF MATCH MAIN HOUSE 1/X6 BA5EBOARD5, 1X4 AROUND THE DOORS G8 DRYWALL WRAP WINDOW5 4 51DED G9 WATER SHUT OFF 010 H05E BI135- LEAVE ACCE55 AND ALL TO REMAIN 011 FLOORING FOR 5TAIRCA5E TO BE CARPET AND PAD C12 CONCRETE FLOOR PER TO HAVE FLOOR LEVEL: PREP FOR FLOATING FOR CONCRETE A5 NEEDED FOR LVP PRODUCT 013 LEAVE EXISTING SHELVING IN GLO5ET, PAINT TO MATCH THE TRIM G14 POURED PAN FOR 5HOWER. NO BENCH TILE TO BE PROVIDED BY THE HOME OWNER G15 SHOWER NICHE 12W"X 15"H NICHE TO BE PAN MOA510, SEE FL7 G16 FIN15H ALL WALL5 AND CEILING WITH DRYWALL IN THE STORAGE ROOM G17 ALL WALL5 ARE TO BE 2X4 G05TRUGTION UNLE55 NOTED OTHERWISE C18 NEW A/C UNIT TO BE LOCATED AT SOUTH EAST OF HOME. HVAG CONTRACTOR TO VERIFY G19 REUSE EX51TING BASEMENT HANDRAIL, PAINTING TO MATCH TRIM, REINFORCE WITH NEW BRACKETS, BN 11 INSULATION NEEDED IN WALL5 5EPERATING THE 5TOAGE AREAS TO THE LIVING QUARTER5 R19 BATT 12 EXTEND INSULATION BELOW EXISTING TO FLOOR ON ALL WALL5 NEEDED 13A5EMENT REMODEL PLAN 5CALE: 11b" = 1'-0" GRAWL SPACE HATCH DOOR 5GHEDULE CRAWL SPACE 8'-10.37" iI T-7 3/4" NORTH L 5t Pi m P3 N G13 G16 STORAGE/ 1 r' x 13' BATH O P '01. X B. h _ g AG D3 11 G5� 11 _ P5 Ea KIDS ZONE 1 in m ri /j 12 C9 2 r� 01 3066 6 PANEL, HOLLOW GORE, WHITE MDF, HINGES BN, DOOR HARDWARE -HANDLE 5GHLA6E TBD 02 2666 BI -FOLD 6 PANEL, KEEP, REMOVE AND REUSE, PAINT TO MATCH 03 2668 6 PANEL, HOLLOW GORE, WHITE MDF, HINGES BN, DOOR HARDWARE -HANDLE 5GHLAGE TBD 04 2668 6 PANEL, HOLLOW GORE, WHITE MDF, HINGES BN, DOOR HARDWARE -HANDLE 5GHLAGE TBD D5 5068 6 PANEL, HOLLOW GORE, WHITE MDF, HINGES BN, DOOR HARDWARE -HANDLE 5GHLAGE TBD D6 2668 6 PANEL, HOLLOW GORE, WHITE MDF, HINGES BN, DOOR HARDWARE -HANDLE 5GHLA6E TBD D7 2668 6 PANEL, HOLLOW GORE, WHITE MDF, HINGES BN, DOOR HARDWARE -HANDLE 5GHLAGE TBD 19'-11.75" 120 ry BEDROOM 1 m 16'-6" X 13'-4" H/AG /AG �ET H4 _ E9f AG L /\A IC 4TH / IIL ", D, Eb ET < Jin Q X O 37'-2" W H4 G3 C1B NG UNIT TO = EE II LOCATED HERE �12 E/lJ- / ry GYM m 13'-0" X 13'-4" in 13'-0.75" TILE AND FLOORING NOTES FL1 5HOWER FLOOR POURED PAN H/O PROVIDE TRAVERTINE MATERIAL. GROUT COLOR TBD, PENCIL FOR VERTICAL FIN51HED EN05 FL2 5HOWER WALL5 H/O PROVIDE TRAVERTINE MATERIAL. GROUT COLOR TBD, PENCIL FOR VERTICAL FIN51HED ENDS FL3 5HOWER CURB TRAVERTINE TILE FL4 BATHROOM FLOORING LVP TO MATCH BASEMENT FL5 BASEMENT 5TAIR5 TO HAVE CARPET AND PAD, 5TRINGER5 TO BE PAINTED, HOLLYWOOD STYLE FL6 5HOWER DRAIN TO BE 5QUARE BN FL7 5HOWER NICHE- 5HOWER PAN TILE IN NICHE 15"H X 12"W, NO SHELF (C15) FLS BASEMENT FLOOR TO BE LVP INCLUDES M015TURE BARRIER (G3, G12) GLA55 SHOWER DOOR BIPA55 WITH EXP05ED TRACK BN City 0i Wheat Diviso!` a z D z z 01 m LU r Y VI I N FTIQ 12..19 INCTE5 1.13.20 IFINAL NOTE m m W v o W v p� U- LLf LU < I� p N Z m < U] K These drawings and specifications are the property and copyright of Keystone Consulting, LLG and shall not be used on any other work except by agreement with Keystone Consulting, LLC. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLC, prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLC, accepts no responsibility for measurements and use of the plan by others. DRAWIN65 PROVIDED BY: Chelsea De Felice DATE: 1/14/20 SCALE: SHEET: FP 2.1 0 FLOOR & TILE NOTES F1 WOOD THROUGHTOUT MAIN FLOOR- PRODUCT AND 5TAIN TBD ** WOOD TREADS TO MATCH MAIN FLOOR PRODUCT *`*Rl5ER MATERIAL TO BE PAINTED COLOR TBD CONSTRUCTION NOTES G1 ALL DIMENSIONS ARE TO BE 51TE VERIFIED G2 ALL FRAMING TO BE 2X4 AND REMAIN A5 15 UNLESS NOTED OTHERWISE ON THE PLAN G3 DIMENSIONS FOR CABINETS ARE A55UMING DRYWALL FIN15H ON WALLS (NOT ON KNEE WALL), VERIFY AND REFER TO 2020 ELEVATIONS FOR INSTALL G4 ALL WINDOWS AND DOORS TO REMAIN A515. INTERIOR DOORS TO BE REINSTALLED AND PAINTED G5 FIREPLACE/LIVING ROOM/DINING TO RETAIN EXI5TING PATRIGLE BOARD ON THE FLOORS. FILL IN WITH 056 TO MATCH THIGKNE55 FOR THE REST OF THE ROOM Gb PLANS ARE A55UMIN6 THAT THE MAIN PLUMBING 5TAGK IN THE KITCHEN TO REMAIN. Gl SOFFIT OVER THE KITCHEN WILL BE 10"H. VERIFY SOFFIT SPACE WILL BE REVISED A5 NEEDED. G5 KNEE WALL AT 15LAND TO BE FRAMED 2X4 AT FRONT 2X6 AT SIDES FIN15H R.O. AT 34.5 TO TOP PLATE TO ALLOW FIN15H TO BE AT 36"H. DO NOT INSTALL DRYWALL. CABINETS WILL BE SET DIRECTLY TO THE ROUGH FRAMING G9 BUILD UP THE FIREPLACE ROOM FLOOR TO MATCH UP WITH THE EXISTING KITCHEN FLOOR (APPROX 5"). ELECT OUTLETS IN FLOOR WILL NEED TO BE RELOCATED. VERIFY WITH LICENSED ELEOTRIGAN. C10 FRONT/ENTRY ROOM TO RETAIN EXISTING PARTICLE BOARD ON THE FLOORS. FILL IN WITH 05B TO MATCH THIGKNE55 FOR THE REST OF THE ROOM G11 INSTALL METAL BANDING/BRACKET5 AT 15LAND FOR COUNTERTOP OVERHANG. CONTRACTOR TO VERIFY WITH FABRICATOR G12 REMOVE DOORS, JAMB AND GA5E OPENING G13 REMOVE DOORS, JAMB AND CASE OPENING C14 GEMENT BOARD ON EAST SIDE, FOR SOUND BARRIER. IN51DE OF BATHROOM TEXTURE TO MATCH G15 DRYWALL OVER WHERE THE OLD INTERCOM 5Y5TEM WAS G16 P05T TO WRAP AROUND PLUMBING IN KITCHEN. ADD SPACE IN P05T FOR INSULATION, AND ELECT. P05T TO BE 15"X 15" 51TE VERIFY WITH PM. FIN15H NOTE TO WRAP P05T IN ALDER, 5TAIN TO MATCH CABINETS G1 PAINT THE FIREPLACE BRICK WHITE TO MATCH THE TRIM G15 ...... CON ..... MAIN FLOOR REMODEL PLAN SCALE: 11Y = 1'-0" 1 T-6 3/4" D13 17'-11 15/16" NORTHI G12 / -,' a.. E10 / Ell ®°'E14 P1 P2 P3 / — P10 FAMILY ® FLOOR KITCHEN ° ° �...17 .a ELEVATIONqL E9 P4'^ I 1T-8" X21'-31. CHANGE �8'-4" X 10'-10" E13 VJ P5 y 3'-0'1/8" G7 a ry m m�t E16 6'-5 /16" E15 0 FAMILY / 1 _9„ X 0.5.. P6 E12 vffyo \ - 622 Pl P8 P9 r G7 0 12 r _ C13 615 G112 11 614 PS .+ O o D10 i;LAUN1)RY B D8 12'_5° X 5'_10" 12'-9.25" -11.' CLOSET 10" x 11-11, LIVING D11,�e 13'-4" X 18'-3" HAL 12-3"X5--11" \ \ GARAGE ry 5TUDY D12 \' 12'-5" X 14'-0" 016 POWDER BATHROOM CABINET WILL BE FLOATING. INSTALL PLYWOOD BACKING 24"W X 36"H TO SUPORT CABINET. SEE 2020 PLANS FOR DETAILS C19 INSTALL BRACKETS FOR FLOATING SHELVES AT RANGE WALL. FIRST SHELF TO BE 54"AFF. SECOND SHELF TO BE 15" ABOVE FIRST SHELF. 5HELVE5 TO BE BUILD TO APPREAR AS FLOATING. 2"THICK, 24"W X 12"D. SITE VERIFYWITH PM C20 MAKEUP AIR FAN WILL NEED TO BE LOCATED IN KITCHEN. LOCATION TBD C21 STAIRS TO THE UPSTAIRS LEVEL: STAIR TREADS TO BE REMOVED IN ORDER TO RELIEVE NEW HARDWOOD STAIR N051NG. 5TRINGER5 TO REMAIN, TREADS AND STRINGERS TO BE PAINTED TO MATCH THE TRIM C22 FUR OUT LAUNDRY SHOOT WALL AND WALL TO THE RIGHT OF THE BAR TO FIN15H AT 26"D COUNTER TOP NOTES CT1 COUNTERTOP WHITE MACAUBAS THROUGHOUT KITCHEN CT2 BACK5PLA5H TO BE TILE, FULL HEIGHT TO CEILING (HOOD WALL) CT3 BACK5PLA5H AT BAR TO BE 1 b"H COUNTERTOP TO WALL CABINET APPLIANCE NOTES AP1 015HWA5HER REUSE THE EXISTING AP2 FRIDGE AP3 MICROWAVE AP4 SLIDE IN RANGE GA5/ELECT DUAL FUEL AP5 HOOD AP6 BEV FRIDGE SEE GUT SHEETS ON SPEC 6.1 FOR INSTALL INSTRUCTION DOOR SCHEDULE 05 2668 EXTERIOR GARAGE DOOR, REUSE EXISTING, PAINT TO MATCH D9 2668 REUSE 6 PANEL D10 2665 REUSE b PANEL D11 4068 REUSE BI-PA55 6 PANEL D12 FRONT DOOR TO REMAIN A515 013 BACK DOOR TO REMAIN A515 City of NEW HARDWARE TBD, BN NEW HINGES BN (wheat !? DI, a Z F W Z o � U W _ Z O Cn W Y DATE 11 R VI I N P 12..19 INUTE5 1.18.20 IFINAL NOTE m m W o Nj o co LU n� 1j) LL W LLI O 1 f� zm< W �L = These drawings and specifications are the property and copyright of Keystone Consulting, LLG and shall not be used on any other nark except by agreement with Keystone Gonsulting, LLG. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLC prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLC accepts no responsibility for measurements and use of the plan by others. DRA,IING5 PROVIDED BY: Ghelwa DeFelice DATE: 1/14/20 SCALE: I SHEET: FP 2.2 KEYSTONE CONSULTING CON5TRUGTION NOTES G1 ALL DIMENSIONS ARE TO BE 51TE VERIFIED 62 ALL FRAMING TO BE 2X4 CONSTRUCTION UNLE55 OTHERWI5E NOTED 03 DIMENSIONS FOR CABINETS ARE ASSUMING DRYWALL FINISH, VERIFY AND REFER TO 2020 ELEVATIONS FOR INSTALL G4 ALL WINDOW5 TO REMAIN A5 15 G5 ALL DOORS TO REMOVE, PAINT AND REINSTALL, OLD HARDWARE TO BE REMOVED AND REPLACED. NEW DOORS ARE NOTED. 016, 018 G6 PLANS ARE A55UMING THAT THE MAIN PLUMBING STACK WILL REMAIN SEE REFLECTED CEILING PLAN RCP 4.3 C1 WALL AT SHOWER TO BE 5'H WITH GLASS TO SIT ATOP, ALLOW 12" GLEARENGE FOR AIR GAP AT THE CEILING. GS KEEP DRAIN IN EXISTING LOCATION. SEE REFLECTED CEILING PLAN FOR RELOCATION RCP 4.3 G9 FRAME WALL5 AT MASTER CL05ET PER PLAN C10 REFRAME WALL IN KIDS BATHROOM 2X6 FOR POCKET DOOR 611 MASTER 5HOWER PAN TO BE POURED WITH A 12"D X 15"H BENCH, LOCATE PER PLAN G12 FIBERGLASS 5HOWER PAN TO BE INSTALLED AT KIDS BATH 613 30" OPENING INTO CLOSET. DRYWALL WRAPPED FOR BARN DOOR AT A LATER DATE. INSTALL BLOCKING AT HEADER AND SIDE WALLS FOR FURTURE HARDWARE 614 NEW POCKET DOOR TO REMAIN 615 VERIFY SKYLIGHT LOCATIONS FOR THE MASTER WALL FOR THE TOILET AND SHOWER C16 KI05 BATHROOM CORNER BENCH. INSTALL (2) BRACKETS PRIOR TO DURAROCK. 011 FLOOR TO RETAIN EX15TINO PATRICLE BOARD ON THE FLOORS. FILL IN WITH OSB TO MATCH THICKNESS FOR THE REST OF THE ROOM 618 BUILD A 2X4 WALL IN FRONT OF EXISTING WALL AT MASTER VANITY EXTERIOR WALL. RUN PLUMBING AND ELECT INTO NEW WALL 619 MASTER BATHROOM TOILET TO BE WALL MOUNTED. MOVE PLUMBING INTO THE WALL. ADD BACKING IN WALL TO HOLD THE TOILET. SEE SPEC SHEET FOR DETAILS UP5TAIR5 REMODEL PLAN SCALE: 11b" = V-0" COUNTER TOP NOTE5 GT1 K105 Vanity Countertop - Quartz. Refer to selection pack. GT2 BENCH - Quartz. 15" AFF. Refer to selection pack. 6T3 MASTER Vanity Countertop - Quartz. Refer to selection pack. GT4 BENCH - Quartz. CORNER. 18" AFF. Refer to selection pack. GLA55 NOTE5 61 MASTER BATHROOM GLASS FOR 5HOWER TO BE EURO 3/8" GLASS, CLEAR, D HANDLE FIN15H TBD. SLIDER, EXP05ED HARDWARE 62 KIDS BATHROOM GLASS FOR 5HOWER TO BE EURO 3/8" GLASS, CLEAR, D HANDLE FIN15H TBD. SLIDER, EXP05ED HARDWARE FLOOR & TILE NOTES KIDS BATHROOM F1 SEE SELECTION PACKET FOR 5PEGIFIGATION5 AND LAYOUT F2 SHOWER WALL5-5EE ELEVATIONS FOR LAYOUT AND SELECTION PACKET FOR 5PEGIFICATION5 F3 5HOWER NICHE- ON CLOSET WALL 15W X 12H; SHELF AND BOTTOM TO BE 50LID SURFACE MASTER BATHROOM F4 FLOOR -TILE SEE ELEVATION FOR LAYOUT AND SELECTION PACKET FOR FOR SPECIFICATIONS F5 5HOWER WALL5-TILE; SCHLUTER VERTICAL ENDS SEE ELEVATION FOR LAYOUT AND SELECTION PACKET FOR 5PEGIFIGATION5 F6 5HOWER FLOOR- TILE; 5HOWER CURB 50LID SURFACE SEE ELEVATION FOR LAYOUT AND SELECTION PACKET FOR SPECIFICATIONS F1 5HOWER BENCH -TILE; 12"D X WIDTH OF 5HOWER, BENCH TOP 50LID SURFACE FS 5HOWER NICHE -TILE; ON BENGH WALL, SHELF AND BOTTOM TO o BE 50LID SURFACE F9 KNEEWALL-GAPPED WITH SOLID SURFACE 1 CARPETED AREAS; F9 HALLWAY, MASTER BEDROOM AND GLO5ET, BED #1, BED #2 AND BED #3 DOOR 5CHEDULE 014 2665 REUSE 6 PANEL 015 OPENING INTO CLOSET TO BE JAMB AND CASED IN MDF 1X4 TO MATCH WHOLE HOUSE PROFILE D16 2468***NEW*** 6 PANEL 0112468 REUSE 6 PANEL 018 2468 ***NEW***POCKET D19 2665 REUSE 6 PANEL, 020 5066 REUSE- SLIDER 6 PANEL 021 5066 REUSE SLIDER 6 PANEL 022 2668 REUSE- SLIDER 023 2668 REUSE 6 PANEL 024 5068 REUSE- SLIDER 6 PANEL 025 4065 REUSE BIFOLD DOORS AT LINEN IN KI05 BATHROOM OLD HARDWARE TO BE REMOVED AND REPLACED PAINT ALL DOORS GEL STAIN BLACK- SEE SELECTION PACKET FOR COLOR 11'-8.15" Fr BATH 5'-0" X 5'- 020 BEDROOM 3 Pi D19 021 022 m BEDROOM 2 11'-2" X 15'-0" 11'-2.38" 13'-1.12"- 18'-1 T-3 3/4" 9'-b 30' E5'-11/16" 6'-11/4" o GT4' P1 4 Pa 62 P2 E9 GT1 P1 �} MA TE BR H / 13' 1" X 2'-11 G13 D18 D16 615 C15 D15 OSET G14 „ 61 P6 P`10� F11 E83 jaP3 GT2 5'-2 5/5" 011 BATH 5'-0., X 5' D1a D23 1124 113.5" Q ry N BEDROOM 13'-1" X 1 B'-5" 8BEDROOM1 11'-3,, X 10'-1" 15'-2.13" 13'-1.15" Ci: eat k,. Di, a z F_ z Uj z 0 Y R VI I 12..19 NOTES 1.13.20 FINAL NOTE m m W o v o W V � O � LUN �~0 17- zm< LU �L = These drawings and specifications are the property and copyright of Keystone Consulting, LLC, and shall not be used on any other work except by agreement with Keystone Gonsulting, LLG. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLC prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLC accepts no responsibility for measurements and use of the plan by others. DRAKN65 PROVIDED BY: Chelsea DeFelice DATE: 1/14/20 SCALE: SHEET: FP 2.3 - ALL PLANS A55UME ALL DEMO HA5 BEEN COMPLETED AND IN5PECTED BY A LICENSED CONTRACTOR i `* ALL PLAN5 HAVE BEEN PROVIDED BY THE HOME OWNER KEYSTONE CONSULTING 4'-4l/16" 13'-51/8"�I ONLY NEW WALL TO BE BUILT 2X4 fl 5EE FP2.1 AND RCP 4.1 FOR ALL NOTES wheat R�d9e FRAMING BASEMENT PLAN 5CALE: 1/5" = V-0" B Di��son O z CA z o W z O N } W Y DATE E5QRIFTIGN R V N 12.6.19 INOTE5 1.13.20 IFINAL NOTE m m LU o 0 Lu 0CkI.- LULL ui �~0 N�� zm< L11 These drawings and specifications are the property and copyright of Keystone Consulting, LL(, and shall not be used on any other work except by agreement with Keystone Consulting, LLG. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Gonsulting, LLC, prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLG accepts no responsibility for measurements and use of the plan by others. DRAWIN65 PROVIDED BY: Chelsea DeFelice DATE: 1/14/20 SCALE: I SHEET: DM 3.1 T Z Z pool, ' U KEYSTONE CONSULTINGDATE Z O r W Y R VI I N I 12.6.19 NOTES 1.13.20 FINAL NOTE m M � o v � wv4 A� w�� I m 2x6 51DE WALLS 2X4 FRONT WALL DO NOT WRAP WALL IN DRYWALL zm� 9'-b 13116" 16'-9 3/16" LU G3 G22 I Gb I BUILD WALLS OUT G8 10'-6"� I G16 26-9 1/2" TO FIN ISH AqVF = - These drawings and specifications are the property and copyright of Keystone Consulting, LLC and shall not be used on any other work except by agreement with Keystone Consulting, LLC. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLC prior to the — — — commencement of any work. Any item not on — — this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLC, 5EE FP2.2 AND RCP 4.2 FOR ALL NOTES City of Wheat Ridge Building [?ivison FRAMING MAIN FLOOR PLAN 5GALE: 1/8" = 1'-0" accepts no responsibility for measurements and use of the plan by others. DRAWINGS PROVIDED BY: Chelsea De Felice DATE 1/14/20 SCALE: I SHEET: DM 3.2 lv�-. a z F z W KEYSTONE CONSULTING z O Y W Y R VI N DATE 12..19 NOTE5 1.13.20 FINAL NOTE m M LU o v o UJ O � ;-b l(i LL LU LU ~ Li G12 G1 ZmLU G13 w 614 u u a T These drawings and Lspecifications are the 6-2 7/6" G9 property and copyright of Keystone Consulting, a LLG and shall not be used on any other work ❑ except by agreement with Keystone _ Consulting, LLG. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLG prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone 5EE FP2.3 AND RCP 4.3 FOR ALL NOTES Consulting, LLG accepts no responsibility for measurements and use of the plan by others. DRAININ65 PROVIDED BY: Ghelsea DeFelice DATE: C� D 1/14/20 SCALE: 'Dill, 0 SHEET: FRAMING UP5TAIR5 FLOOR PLAN 56ALE: 1B" = 1'-0" DM 3.3 KEYSTONE CONSULTING HVAC, NOTES H1 ALL EXISTING VENTS TO REMAIN H2 ALL NEW VENTS OR PENETRATIONS TO BE INSTALLED PER CODE AND LICENSED CONTRACTOR H3 NEW EXHAUST FANS FOR THE BATHROOMS TO USE THE EXISTING EXTERIOR PENETRATIONS. NEW EXHAUST FANS TO BE 5PECIFIE0 AND PROVIDED BY HVAC CONTRACTOR H4 FURNANGE, UPGRADE TO HIGH EFFIGENGY AND ADD A/C, NEW FURNANGE WILL NEED TO BE TIED INTO EXISTING SYSTEM. H5 PLAN FOR FUTURE AG UNIT TO BE TIED INTO FURNANGE. LOCATION TO BE AT THE SOUTH EAST 51DE OF THE HOME. GUT HOLES IN THE 51DE OF THE HOME FOR THE FURNANGE. FOAM ALL PENETRATIONS PER CODE. KEEP WITHIN THE TING SOFFIT ELECTRICAL NOTE5 E1 REPLACE ALL EXHAUST FAN, INTO A FAN/LIGHT COMBO IN THE BATHROOMS. USE EXISTING PENETRATIONS E2 ALL GFCI5 TO BE INSTALLED PER CODE E3 ALL OTHER OUTLETS TO BE INSTALLED PER CODE, CHANGE HEIGHT TO 42"AFF CONFIRM WITH CLIENT AND CONTRACTOR E4 ALL OUTLETS AND 5WITGHE5 WHITE TO MATCH EXISTING, HEIGHT OF 5WITGHE5 TO MATCH EXISTING HEIGHTS E5 (23) b" REGE55ED CAN LIGHTS WITH WHITE TRIM BAFFLE TO BE PLACED IN THE BASEMENT. (1) 5HOWER WATER TRIM KIT AT 5HOWER LOCATIONS TO BE VERIFIED BY THE CONTRACTOR Eb (12) 5WITGHE5 TO BE PLACED IN THE BASEMENT. (2) 3 -WAY AT BEDROOM/5TAIR5. (1) DIMMER AT KI05 ZONE, (1) DIMMER AT GYM. LOCATIONS TO BE VERIFIED BY THE LICENSED CONTRACTOR, MATCH EXISTING, HEIGHT OF 5WITGHE5 TO MATCH EXISTING HEIGHTS E7 SMOKIE5/GO2 TO BE INSTALLED PER CODE E8 ADD (2) REGE55ED SCONES AT THE STAIRCASE E9 TV/COAX/CATV E10 MAY NEED TO ADD SUB PANEL DUE TO REMODEL AND FOR FUTURE A/C BA5EMENT REFLECTIVE CEILING PLAN SCALE: 1/4" = V-0" PLUMBING NOTE5 SEE SELECTION PACKET FOR SPECIFICATIONS P1 TOILET REMAIN IN CURRENT LOCATION, REUSE EX5ITING TOILET LOCATED IN THE GARAGE P2 VANITY REMAIN IN CURRENT LOCATION H/O TO PROVIDE (ALL IN ONE VANITY WITH MIRROR/LIGHT FIXTURE) P3 5HOWER TO REMAIN IN GURREGT LOCATION, SQUARE DRAIN IN BN TO BE PROVIDED BY CONTRACTOR P5 GAP ALL EX15TING PLUMBING AT BAR- NOT TO BE REUSED Pb 5140WER/HANDHELD IN ONE UNIT, 1 VALVE. SEE SELECTION PACKET H4 G3 :18 A/G 1N IT TO VE OGATED IERE Divison 0 z z o U W Z t•- tn Y DATE FTION W Y R VI I N 12.6.19 NOTES 1.13.20 IFINAL NOTE m m ' `U Q) V O LU Q� LL- Ld W d �~Q N�� zm4 LU 1L 2 These drawings and specifications are the property and copyright of Keystone Consulting, LLC and shall not be used on any other work except by agreement with Keystone Consulting, LLC,. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLG prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLC, accepts no responsibility for measurements and use of the plan by others. DRAWINGS PROVIDED BY: Chelsea DeFelice DATE: 1/14/20 SCALE: SHEET: RCF 4.1 V1 KEYSTONE CONSULTING ELECTRICAL NOTES E1 REPLACE EXHAUST FAN, TO BE FAN LIGHT COMBOS E2 ALL GFCI5 TO BE INSTALLED PER CODE E3 ALL OTHER OUTLETS TO BE INSTALLED PER CODE E4 ALL OUTLETS AND 5WITGHE5 WHITE TO MATCH EXISTING, MATCH EXISTING HEIGHTS IN THE ENTIRE HOME E5 (20) 6" RECESSED CAN LIGHTS WITH WHITE TRIM BAFFLE TO BE PLACED. WARM LIGHT E6 (11) 5WITGHE5 TO BE PLACED PER PLAN, (4) DIMMERS TBD, (2) 3 -WAY. LOCATIONS TO BE VERIFIED WITH PM El (2) FLOOR OUTLETS IN THE FIREPLACE ROOM FLOOR WILL NEED TO BE MOVED UP INTO THE NEW FLOOR. ES 5MOKIES/CO2 TO BE INSTALLED PER CODE E9 110V 20AMP FOR FRIDGE. SEE SPECS FOR ALL APPLIANCES (HOME OWNER PROVIDED) E10 220V 30 AMP 6A5/ELECT RANGE; El 1 110V 20AMP HOOD E12 110V 20AMP BEV FRIDGE UNDERCOUNTER AT BAR E13 110V 20 AMP D15HNA5HER E14 110 AMP 20AMP GARBAGE 015P05AL E15 (4) U5B/OUTLET-NHITE OUTLETS AT 15LAND ON EITHER END. LOCATION TBD BY CLIENT AND CONTRACTOR E16 (1) LIGHT FIXTURES OVER DINING TABLE Ell PONDER BATHROOM TO HAVE UNDERGABINET LIGHTING AT FLOATING CABINET. ADD OUTLET10"AFF FOR LED STRIP El (1) VANITY LIGHT IN THE PONDER BATHROOM E19 (3) 4" CANS AT THE FIREPLACE 5WITCHED ON A SEPERATE DIMMER E20 (2) SCONCES IN THE BASEMENT STAIRCASE E21 KITCHEN CABINETS TO HAVE TOE KICK LIGHTING E22 KITCHEN BAR TO HAVE UNDERGABINET LIGHTING E23 MICRO OUTLETS AT ISLAND, UNDERCOUNTER SEE APPLIANCES SPECS FOR DETAILS E24 BAR SINK TO HAVE GARBAGE 015P05ALL 3/4 BALER WITH STANDARD RING MAIN FLOOR REFLECTIVE CEILING PLAN SCALE: 1/4" = 1'-0" HVAC NOTES H1 ALL EXISTING VENTS TO REMAIN H2 NO NEW VENTS OR PENTRATION5 NEEDED H3 HOOD FOR RANGE WILL NEED TO BE VENTED TO THE EXTERIOR. NEW PENETRATION WILL BE REQUIRED H4 NEW EXHAUST FANS TO HAVE LI6HT5 FOR ALL THE BATHROOMS TO USE THE EXISTING EXTERIOR PENETRATIONS. NEW EXHAUST FANS TO BE SPECIFIED AND PROVIDED BY HVAC CONTRACTOR 1'1'-6 D13 PLUMBING NOTES ALL PLUMBING TO NEED NEW DRAINS, VENTS, AND 5HUTOFF5 P1 24" SINK, SEE 2020 CABINET ELEVATIONS P2 GARBAGE DISPOSAL, 5WITGH AT WALL P3 FAUCET FOR KITCHEN SINK P4 WATER LINE FOR FRIDGE, SEE APPLIANCE SPECS P5 WATER LINE FOR 015HWA5HER, SEE APPLIANCE SPECS Pb PLAN ASSUMES MAIN DRAIN LINE WILL REMAIN, VERIFY WITH LICENSED CONTRACTOR Pl BAR SINK P5 GARBAGE DISPOSAL AT BAR, 5WITGH AT WALL P9 FAUCET FOR BAR SINK P10 GAS LINE TO BE RUN FOR RANGE P11 REUSE TOILET FOR POWDER BATHROOM, NEW WAX RING NEEDED INSULATION NOTES 11 OPEN NALL FOR SERVICES AND `*ADD INSULATION TBD** 12 INSULATE SOFFIT OVER KITCHEN WITH BLOWN IN 1T-11 15/1 I /.... - C12. / E1100 j} E 1 1 E14P1P2P3 P10 FAMILY ® FLOOR KITCHEN i / ELEVATION ". "'"„ „._ E9 P4 1l'-8" X 21'-3" CHANGE 8'-4" X 10'-10" E13 C-1 ry W 5 O E16 E15 0 FAMILY C111 X 0._5.. P6 E12 \i, - G22 Pl P8 P9 r Gl O 12 ; _ C13 615 d 6112 11 G14 P5 +. T 0 G18 E1'I O 010 in LAU N D RY 13 a DB 12'-5" X 5'_10" D9 12'-9.25" CLOSET 10^xr-t t' LIVING D11. 13'-4" X 18'-3" HALLS 12-3"X5--11" GARAGE n STUDY 12-5" X 14'-0" rf� 0 z D U) o Poll W U z 0 r W Y R VI I N 12.6.19 INOTE5 1.13.20 IFINAL NOTE m m LU o V � LU V D� LU d lU ~� W NITV ZM< W �L = These drawings and specifications are the property and copyright of Keystone Consulting, LLC, and shall not be used on any other work except by agreement with Keystone Consulting, LLC,. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLC, prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLG accepts no responsibility for measurements and use of the plan by others. DRANING5 PROVIDED BY: Chelsea De Felice DATE: 1/14/20 SCALE: I SHEET: RGP 4.2 KEYSTONE CONSULTING HVAC NOTES / H1 ALL EXISTING HEAT VENTS TO REMAIN H2 NO NEW VENTS OR PENETRATIONS TO BE INSTALLED H3 NEW EXHAUST FANS/LIGHT COMBO FOR THE BATHROOMS TO USE THE EX15TINO EXTERIOR PENETRATIONS. NEW EXHAUST FANS TO BE SPECIFIED AND PROVIDED BY HVAC CONTRACTOR ELECTRICAL NOTES E1 REPLACE EXHAUST FANS IN EACH WATER CL05ET WITH FAN/HEAT LIGHT COMBO (BLUE) E2 ALL GFC15 TO BE INSTALLED PER CODE E3 ALL OTHER OUTLETS TO BE INSTALLED PER CODE E4 ALL OUTLETS AND 5WITGHES WHITE TO MATCH EXISTING E5 (10) 6" RECESSED CAN (WARM) LIGHTS WITH WHITE TRIM BAFFLE TO BE PLACED PER THE DRAWING. (2) WATER TRIM KITS FOR THE NET LOCATIONS (5HOWER5) LOCATIONS TO BE VERIFIED BY THE CONTRACTOR E6 (10) 5WITGHES TO BE PLACED PER THE DRAWING. LOCATIONS TO BE VERIFIED BY THE LICENSED CONTRACTOR El 5MOKIE5/CO2 TO BE INSTALLED PER CODE ES (2) PENDENT5 AT THE VANITY LIGHTS AT THE WALL IN THE MASTER BATHROOM. LOCATION AND PRODUCT TO BE VERIFIED ON 51TE E9 (2) PENDENT VANITY LIGHTS DIMMABLE AT THE WALL IN THE KIDS BATHROOM. LOCATION AND PRODUCT TO BE VERIFIED ON 51TE E10 VANITIES TO HAVE UNDERGABINET LIGHTING FOR MASTER AND KIDS BATHROOM UP5TAIR5 REFLEGTIVE CEILING PLAN 5GALE: 1/4" = 1'-0" 021 13'-1.12" 16'-1 3/4" T-3 3/4" 9'-b 3/6" I. MASTER t BATH 6-11/4" 18'-1" x 8'-1" Gib CT F3 P14 1, ,v - BATH 5'-0" X 5'4 ry G16�G2 E9 GTt P7 / Q 020 016 P2 D16 ,C15 C13 3ED OOM 3 c10 G1s�G1 \ 11s' G14 „ / o 111- "X 10'-11" a G73 n\; Pb P10 F�1 �+ 9,2 124 Eb IU 6-21/8" GT2 a 5'-2 5/6" D19 D11 BATH �} 014 zffl.r ®I ry BEDROOM i 1 r-2° x 15'-0" 8 BEDROOM 1 11'-3" X 10'-T' IIry BEDRO v 13'-1" X 18'-5" PLUMBING NOTES ALL PLUMBING TO NEED NEW DRAINS, VENTS, AND 5HUTOFF5 KI05 BATHROOM P1 CHANGE TUB VALVE AND TRIM INTO A 5HOWER TRIM AND VALVE P2 TOILET TO REMAIN IN THE EXISTING LOCATION P3 DOUBLE VANITY TO REMAIN IN EXI5TING LOCATION P4 SHOWER -PREFAB PAN MASTER BATHROOM P5 TOILET SHIFTS DUE TO MAKING THE TOILET A WALL HUNG FIXTURE FLANGE TO AGCOMIDATE, ROUND BOWL P6 5HOWER DRAIN REMAINS IN THE EX15TING LOCATION. 5QUARE C8. SCHLUTER 5Y5TEM PI DOUBLE VANITY TO BE ADDED INTO THE NEW 2X4 WALL SEE VANITY FOR DRAIN LOCATIONS P8 NEW PEDESTAL TUB, SEE SPEC FOR DRAIN LOCATION P9 FLOOR MOUNTED FAUCET SEE SPEC FOR INSTALL AND 51TE VERIFY LOCATION P10 5HOWER/VALVE DIVERTER WITH RAIN HEAD, HAND HELD, AND MAIN. SEE SELECTION PACKET AND ELEVATIONS FOR IN5TALL.TBD 1 a Z H Z U W Z O W r W Y R VI I 12..19 INOTES 1.13.20 FINAL NOTE m m w o v o W V LL W �~C1, � CAIY Zll W Y = These drawings and specifications are the property and copyright of Keystone Consulting, LLG and shall not be used on any other work except by agreement with Keystone Consulting, LLG. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLG prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLG accepts no responsibility for measurements and use of the plan by others. DRANING5 PROVIDED BY: Chelsea DeFelice DATE: 1/14/20 SCALE: SHEET: RGP 4.3 z F U) W KEYSTONE CONSULTING' z O0 ti W Y R VI I N 12..19 NOTE5 1.13.20 FINAL NOTE m m LU o v o wv� co O� Qlll r—kD � zM< LU �L 2 These drawings and property and copyright of Keystone Consulting, used on any other work except by agreement with Keystone Consulting, LLC. Written dimensions shall not take preference over scaled dimensions and shall be Any discrepancy shall be brought to the notice of Keystone Consulting, LLC prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLC accepts no responsibility for measurements and use of the plan by others. DRAWINGS PROVIDED BY: Ghelsea DeFelice DATE: 1/14/20 SCALE: SHEET: CONSTRUCTION NOTES TRIM NOTES INSULATION NOTES G1 SEE FP 2.1-2.3 FIR NOTES SPECIFIC TO EACH FLOOR T1 TH15 PLAN ASSUMES THAT ALL BASE AND CASE 15 REMOVED. 11 INSULATION KEEP EXISTING IN ALL LOCATIONS G2 ALL FRAMING TO BE 2X4 CONSTRUCTION UNLE55 NOTED ALL WINDOW TRIM TO REMAIN ON ALL FLOORS. INSTALL ALL NEW 12 REPLACE INSULATION IN ALL EXTERIOR WALLS WHERE IT OTHERWISE BASE, WINDOWS CASE, AND DOORS IN PAINT GRADE A5 BEEN REMOVED IN THE BASEMENT G3 FUTURE SUB -PANEL MAYBE NEEDED FOR FUTURE A/C BASEBOARDS 1X6, CASING AND TRIM AROUND THE DOORS TO BE 13 INSULATE PIPES AT ALL EXTERIOR LOCATIONS UNIT. VERIFY WITH LICENSED HVAC CONTRACTOR 1X4. 14 INSULATE MIDFLOOR AROUND PIPES A5 NEEDED BY G4 GLEAN ALL THE DUCTS T2 REPLACE DOORS WITH 2 PANEL HOLLOW GORE, MDF WHITE. LICENSED CONTRACTOR 15 INSULATE SOFFIT IN KITCHEN HARDWARE TO BE BN AND HANDLES/ DOOR T3 VANITY MIRRORS TO BE LARGE MIRRORS GLUED TO THE WALL �C (PROVIDED BY GLA55 CONTRACTOR) WALL NOTES T4 ALL CABINETS TO BE INSTALLED VIA 2020 DRAWINGS TO BE PROVIDED W1 KNOCKDOWN TEXTURE FOR WALLS AND CEILING T5 BATH ACCESSORIES- REFER TO SELECTION PACKET FOR W2 WALL CORNERS SQUARE TO MATCH EXI5TIN6 STYLE AND FINISH. APPLY BACKING IN WALL AT ALL LOCATIONS. y,43 WATERPROOF CONCRETE BOARD FOR ALL SHOWER/WET specifications are the Tb KEEP ALL WINDOWS EXISTING, PROTECT ALL WINDOWS AND LOCATIONS CASEMENT W4 USE 12' DRYWALL SHEETS FOR BASEMENT/HOUSE OR LLC and shall not be T7 DOOR HARDWARE TO BE REMOVED AND REPLACED EX5ITING. ALLOWED BY ACCESS OPTION TO INSTALL ALL NEW HARDWARE (HANDLES FINISH TBD) W5 ALL GLEAN OUT GONERS TO BE PAINTED SAME COLOR A5 VERIFY WITH PM WALLS Wb PAINT FOR BASEBOARD CASE AND TRIM TBD SEE SELECTION PACKET verified on the job site. Wl PAINT COLORS: TBD 4 -colors (2 color for walls -satin & 1 color for ceilings flat, 1 -for GEL STAIN base/doors/trim eggshell). DOOR NOTES 01 UNLE55 NOTED OTHERWISE ALL DOORS TO REMAIN. !Z EXISTING EXTERIOR DOORS TO REMAIN 02 INTERIOR DOORS TO BE REPLACED A5 NOTED. MATCH fl � EXISTING PROFILE. MATCH EXISTING HARDWARE AND HINGES FPN 5.1 T KEYSTONE CONSULTING APPLIANCE NOTES ALL APPLIANCE SPECS ARE LOCATED IN THE GOOGLE DRIVE FOR REFERENCE Item Description:..JMDFS30HM-JennAir0 NOIRTm 30" Under Counter Microwave Oven with Drawer Design Qty: ............... 1 Item Description:..KRFC704FBS-KitchenAid® 23.8 cu. ft. 36" Counter" Depth French Door Platinum Interior Refrigerator Qty: ............... 1 Item Description:.. KSGG700EBS-KitchenAid® 30" Inch 5" Burner Gas Slide" In Convection Range Qty: ............... 1 Item Description:.. KVWB606HBS-KitchenAid® 36" Wall" Mount, 3" Speed Canopy Hood Qty: ............... 1 Item Description:..WUB50X24HV-Whirlpool® 24" inch Wide Undercounter Beverage Center " 5.2 cu. ft. Qty: ............... 1 DISHWASHER- REUSE EXISTING 0 Z !� z W Z O W Y DATE I R VI I 12 ..19 1 NOTE5 1.13.20 FINAL NOTE m m w o v o wvQ) O � LU �~0 Ir— z m Q W �L = These drawings and specifications are the property and copyright of Keystone Consulting, LLC and shall not be used on any other work except by agreement with Keystone Consulting, LLC. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLC, prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLC accepts no responsibility for measurements and use of the plan by others. DRAWINGS PROVIDED BY: Chelsea DeFelice DATE: 1/14/20 SCALE: I SHEET: 5PEG 6.1 KEYSTONE CONSULTING KITCHEN (RANGE WALL) COUNTERTOPS KITCHEN (ISLAND) COUNTERTOPS KITCHEN (BAR) COUNTERTOP5 V (V 45 5/16" COUNTERTOP TEMPLATE SCALE: 1/2" = V-0" 98 15/16" 121" COUNTERTOP5 NOTES (KITCHEN EASED EDGE AND POLISHED BAR EASED EDGE AND POLI5HED MASTER BATHROOM ALL IN ONE VANITY KI05 BATHROOM ALL IN ONE VANITY BASEMENT BATHROOM ALL IN ONE VANITY MASTER BATHROOM CURB v "13 7/8" MASTER BATHROOM BENCH SEAT m m iv r v 0 Z Z o U W Z 0 Y REVISIONS 12..19 NOTES 1.19.20 FINAL NOTE m m LU o tllVO LL 0 LU w H zm� LU �c 2 These drawings and specifications are the property and copyright of Keystone Consulting, LLC and shall not be used on any other work except by agreement with Keystone Consulting, LLC. Written dimensions shall not take preference over scaled dimensions and shall be verified on the job site. Any discrepancy shall be brought to the notice of Keystone Consulting, LLC prior to the commencement of any work. Any item not on this plan, contract or approved spreadsheet is not included in the scope of work. Keystone Consulting, LLC accepts no responsibility for measurements and use of the plan by others. DRAWINGS PROVIDED BY: Ghelsea DeFelice DATE: 1/14/20 SCALE: I SHEET: SPEC 6.2 ADVANCED ENGINEERING CONCEPTS, INC. 384 Park Court (303) 814-2308 Castle Rock, CO 80109-1500 FAX (303) 814-2317 August 10, 2019 David A. Kuntz, P.E. Subject: Plan Release 3244 Taft Court Wheat Ridge, Colorado 80033 To Whom It May Concern: Please release all record plans and documents on file with the city of Wheat Ridge with my stamp and signature for the residence at 3244 Taft Court, Wheat Ridge, CO 80033 to the current homeowner(s). Sincerely, ADVANCED ENGINEERING CONCEPTS, INC. Michael L. Schneider, P.E. City of Wheat Ridge Homeowner Demolition PERMIT - 201901576 PERMIT NO: 201901576 ISSUED: 07/31/2019 JOB ADDRESS: 3244 Taft Ct EXPIRES: 07/30/2020 JOB DESCRIPTION: Demo 9,624 sq ft of walls, 3,257 sq ft of ceiling, 3,159 sq ft of floors - 16,040 sq ft total *** CONTACTS *** OWNER (303)304-6049 KUNTZ DAVID A *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,840.38 FEES Total Valuation 0.00 Demolition Fee 50.00 ** TOTAL ** 50.00 *** COMMENTS *** *** CONDITIONS *** I, the property owner, by my signature, attest that I currently reside at the project property, intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers. If professionals are hired, those contractors are licensed with the City of Wheat Ridge and are listed on the permit. NOTE: Consultations and inspections will only be performed with the homeowner of record present. All work shall comply 2012 International Codes, 2017 NEC (if applicable), and ordinances adopted by the City of Wheat Ridge. Work is subject to field inspections. City of Wheat Ridge Homeowner Demolition PERMIT - 201901576 PERMIT NO: 201901576 ISSUED: 07/31/2019 JOB ADDRESS: 3244 Taft Ct EXPIRES: 07/30/2020 JOB DESCRIPTION: Demo 9,624 sq ft of walls, 3,257 sq ft of ceiling, 3,159 sq ft of floors - 16,040 sq ft total I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2, This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3 If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and_procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of an manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a pe it shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code gyapy ordinance rpegulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of �`7`I heatps d MUNtTY DEVELOPMENT Building & Inspection Services 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a)ci.wheatridge.co.us I FOR OFFICE USE ONLY I Date: -7/ Plan/Permit # Jq0(5?o Plan Review Fee: Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3244 Taft Ct, Wheat Ridge, CO 80033 Property Owner (please print): David & Michele Kuntz Phone: 303-304-6049 Property Owner Email: davidkuntz0l@gmail.com Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Contractor Name: N. A. City of Wheat Ridge License #: Contractor E-mail Address: Phone: Phone: For Plan Review Questions & Comments (please print): A, CONTACT NAME (please print): .A. Phone: CONTACT EMAIL(p/ease print): Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields, if applicable. ❑COMMERCIAL [ X I RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. A toilet water supply line broke in my house and has caused substantial damage to the flooring and drywall. The initial stage of the reconstruction project will entail removing the damaged material and preparing for rebuild. 9,624 SF Walls, 3.257 SF Ceiling, and 3,159 SF Floors were affected by the water damage, see Travelers Insurance Documents dated 07/30/19. Sq. FULF BTUs Gallons Amps Squares For Solar: Kw # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ General Demolition $2,840.38, See Travelers Insurance Documents dated 07/30/19. OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE:OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): /`� DATE: / Printed Name: David A. Kuntz ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS Reviewer: 1I:4J,1:A1111Ji1:11 INI ka_W11�i1�IA1 OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: II S City of Wh6atl_�jidjgie COMMUNITY DEVELOPMENT Official Certification of Property Owner Permit THIS IS TO CERTIFY that I, the property owner, by my signature, attest that I currently reside at the project property, or intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, list them on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property. Property Owner(s): Du V ' J1 Project Property: 3ZYGi T4. Notarized signature of Applicant State of Colorado } County of e r } ss . /ZM ✓ffZ t G✓ k cu, � 2 � dl The foregoing instrument was acknowledged by me this �_ day of� , 20� by JENNIFER RYAN WILKEN NOTARY PUBLIC STATE OF COLORADO NOTARY ID 20174034532 MY COMMISSION EXPIRES 08/16/2021 DO ary Publi My Commission Expires / i �/20,-)( Purpose of Inspection: On July 1, 2019 L&K Environmental had been contracted to perform a limited asbestos inspection and bulk sampling for suspect asbestos containing building material (ACBM). f the amount of ACM to be disturbed exceeds the following trigger levels, then an asbestos abatement contractor must remove the material: Single -Family Residential Dwellings ("SFRD") - the trigger levels are: 50 linear feet on pipes; 32 square feet on other surfaces; or the volume equivalent of a 55 -gallon drum. Public and Commercial Buildings (other than SFRDs) - the trigger levels are: 260 linear feet on pipes; 160 square feet on other surfaces; or the volume equivalent of a 55 -gallon drum. The purpose is to identify possible ACBM that is to be disturbed, determine the condition of suspect materials, and determine homogeneous areas where suspect materials are being tested. When sampling surfacing material, at least three samples must be collected for <1,OOOsq. ft., at least five samples for between 1,000 - S,OOOsq. ft., and at least seven samples for >S,OOOsq. ft. When selecting sample locations, random sampling is done in accordance with the EPA pink book. Once samples have been collected they must be submitted for analysis. Exclusions: 1. A certified building inspector shall not be required to perform an inspection if based on prior records there has been sampling done and determined no ACM is present. 2. An architect or project engineer who was responsible for the construction of the building signs a statement stating that no ACM was used in any known building material. Laboratory Protocol: All bulk samples will be submitted to an independent NIST accredited NVLAP laboratory. Phase Light Microscopy will be used to analyze samples. All samples <1% will be point counted to determine exact asbestos composition. For each homogenous area samples containing <1% asbestos is considered not to contain asbestos if all samples collected show asbestos in this amount. If any samples within a homogeneous area are found to contain >1% the whole homogeneous area must be treated as asbestos containing. Lab Summary for Samples Collected on July 1, 2019: HA # Sample ID , Material Description Sample Location Material i Affected Friable Asbestos �! Included in HA Classification Category 2 Classification HA in SF (Yes/No) I Content Classification Category SM 1-1 Paint, Texture, Upstairs Master Surfacing 15 Yes ND 1 #7 — Any remaining friable ACM or friable suspected ACM. Drywall Bath Wall, N SM 1-2 Paint, Texture, Upstairs Master Surfacing 15 Yes ND Drywall Bath Wall, NW SM 1-3 Paint, Texture, Upstairs Master Surfacing 15 Yes ND Drywall Bath Wall, NE HA # Sample ID Material Description Sample Location Material Affected Friable Asbestos Classification HA in SF (Yes/No) Content 2 MM 1-1 Joint Compound, Upstairs Master Misc. 20 Yes ND Drywall Bath Wall, NW HA # Sample ID Material Description Sample Location Material Affected Friable Asbestos Classification HA in SF (Yes/No) Content SM 2-1 Paint, Texture, Basement Surfacing 20 Yes ND 3 Drywall Bedroom Wall SM 2-2 Paint, Texture, Basement Surfacing 20 Yes ND Drywall Bedroom Wall SM 2-3 Paint, Texture, Basement Surfacing 20 Yes ND Drywall Bedroom Wall HA # Sample ID Material Description Sample Location Material Affected i Friable Asbestos _ Classification HA in SF (Yes/No) Content 4 MM 2-1 Joint Compound, Basement Misc. 20 Yes ND Drywall Bedroom Wall Summary of Areas Included in HA & Classification Categories: HA # Included in HA Classification Category 1 Upstairs Master Bath Walls #7 — Any remaining friable ACM or friable suspected ACM. HA # Included in HA Classification Category 2 Upstairs Master Bath Walls #7 — Any remaining friable ACM or friable suspected ACM. HA # included in HA Classification Category 3 Basement Bedroom Walls #7 — Any remaining friable ACM or friable suspected ACM. HA # Included in HA Classification Category 4 Basement Bedroom Walls #7 — Any remaining friable ACM or friable suspected ACM. Recommendations: All samples referenced above were collected on July 1, 2019. The materials/areas sampled on July 1, 2019 contained no asbestos. Removal of the suspect materials/areas may be done without abatement activities. Signatory: Attached is the laboratory analysis report and technician certification(s). Please direct any questions or concerns regarding the information in this report to our office at 303-912-5016 and we will be happy to assist. Thank you for choosing L&K Environmental, Inc. Sincerely, Kevin Mackey L&K Environmental, Inc. Building Inspector# 13984 Attachments: Laboratory Analytical Data; Technician Certifications) 8985 E. Nichols Avenue, Suite 350 Centennial, CO 80112 AWA kT Phone +1 303 799 6100 Fax +1303 799 3441 www.atcgroupservices.com PLM REPORT SUMMARY NVLAP Lab Code 102031 Customer: AIHA Lab Code 101536 Kevin Mackey ATC Job No.: L&K Environmental Batch No.: 0028733 9851 Castle Ridge Circle Report Date: 07/02/2019 Highlands Ranch CO 80129 Sample Date: 07/02/2019 Project: Kuntz/ 3244 Taft Court Date Analyzed: 07/02/2019 Customer Project No.: Identification: N/A Test Method: 600/R-93/116 Page 1 of 2 Client No. Lab No. Sample Description / Location Asbestos Content SM 1-1 0028733-001 LAYER 1 None Detected PaintfTexture, White Note: Layer is mainly Paint Upstairs, Master Bath, Walls SM 1-1 0028733-001 LAYER 2 None Detected Drywall, Brown/White, 23°C Upstairs, Master Bath, Walls SM 1-2 0028733-002 LAYER 1 None Detected White/Texture, White, 25°C Upstairs, Master Bath, Walls SM 1-2 0028733-002 LAYER 2 None Detected Drywall, White/ Brown Upstairs, Master Bath, Walls SM 1-3 0028733-003 LAYER 1 None Detected White/Texture, White, 25°C Upstairs, Master Bath, Walls SM 1-3 0028733-003 LAYER 2 None Detected Drywall, White/ Brown Upstairs, Master Bath, Walls MM 1-1 0028733-004 Paint/Joint Compound, White, 25°C None Detected Note: No Drywall Present Upstairs, Master Bath, Walls SM 2-1 0028733-005 LAYER 1 None Detected Paint/Texture, White, 24°C Basement, Bedroom, Ceiling These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. r y 8985 E. Nichols Avenue, Suite 350 Centennial, CO 80112 Phone +1303 799 6100 Fax +1303 799 3441 www.atcgroupservices.com PLM REPORT SUMMARY NVLAP Lab Code 102031 Customer: Al HA Lab Code 10153636 Kevin Mackey ATC Job No.: L&K Environmental Batch No.: 0028733 9851 Castle Ridge Circle Report Date: 07/02/2019 Highlands Ranch CO 80129 Sample Date: 07/02/2019 Project: Kuntz/ 3244 Taft Court Date Analyzed: 07/02/2019 Customer Project No.: Identification: N/A Test Method: 600/R-93/116 Page 2 of 2 Client No. Lab No. Sample Description / Location Asbestos Content SM 2-1 0028733-005 LAYER 2 None Detected Drywall, Brown/Off White, 23°C Basement, Bedroom, Ceiling SM 2-2 0028733-006 Paint/Texture, White, 25°C None Detected Note: No Drywall Present Basement, Bedroom, Ceiling SM 2-3 0028733-007 Paint[Texture, White, 25°C None Detected Note: No Drywall Present Basement, Bedroom, Ceiling MM 2-1 0028733-008 LAYER 1 None Detected Paint/Texture, White, 25°C Basement, Bedroom, Ceiling MM 2-1 0028733-008 LAYER 2 None Detected Drywall Tape, Beige, 23°C Basement, Bedroom, Ceiling MM 2-1 0028733-008 LAYER 3 None Detected Joint Compound, White, 23°C Basement, Bedroom, Ceiling MM 2-1 0028733-008 LAYER 4 None Detected Drywall, Brown/Gray Basement, Bedroom, Ceiling These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. ;�►TC Customer: PLM REPORT SUMMARY Kevin Mackey ATC Job No.: L&K Environmental Batch No.: 0028733 9851 Castle Ridge Circle Report Date: 07/02/2019 Highlands Ranch CO 80129 Sample Date: 07/02/2019 Project: Kuntz/ 3244 Taft Court Date Analyzed: 07/02/2019 Customer Project No.: Identification: N/A Test Method: 600/R-93/116 8985 E. Nichols Avenue, Suite 350 Centennial, CO 80112 Phone +1 303 799 6100 Fax +1303 799 3441 www.atcgroupservices.com NVLAP Lab Code 102031 AIHA Lab Code 101536 Page 1 of 1 PLM Analysis Methodology PLM samples were analyzed utilizing the Environmental Protection Agency's Test Method: Method for the Determination of Asbestos in Building Materials (EPA 600/R-93/116. July, 1993) 40 CFR, Part 763, Appendix E to Subpart E. Reporting Limit <1% Asbestos. Additional treatment and tests may be required to accurately define composition (i.e. ashing, extractions, acetone treatment, and TEM). Unused portions of samples are archived for one year unless client requests special handling. Asbestos content of mastic/adhesive is separated from total percent asbestos and other materials. Laboratory Equipment Laboratory analysis was accomplished utilizing an Olympus BH -2 polarized light microscope. The microscope is equipped with dispersion staining lenses. Quality Control ATC Group Services is accredited by NVLAP Bulk Asbestos Sample Quality Assurance Program (Lab Code 102031). ATC participates in the NVLAP Bulk Asbestos Sample Quality Assurance Program and maintains an in-house QC/QA program for bulk samples whereby 10% of all submitted samples are reanalyzed and documented in a Quality Control Manual. ATC also participates in a quarterly round robin QC/QA program for bulk samples with several accredited laboratories throughout the United States. Current and past QC/QA program results are available in the laboratory for inspection. Laboratory Personnel Samples were analyzed by Jeff Lomme, Laboratory Director. Mr. Lomme is a professional geologist who has successfully completed the McCrone Institutes's "Advanced Asbestos Identification" Course. Approved Signatory. XeffLom�me NVLAP LAB CODE 102031-0 The non -detection of asbestos fibers in floor the by PLM is of itself inconclusive. Confirmation by Transmission Electron Microscope (TEM) is recommended for negative floor tile samples. This report must not be used by the client to claim product endorsements by NVLAP or an agency of the U.S. government. This test reports only to the items stated. �� Cardno" ATC Shaping the Future PROJECT INFORMATION Turnaround: 8985 East Nichols Avenue, Suite 350 Centennial, Colorado 80112 www.cardnoatc.com TEL: 303.799.6100 FAX: 303.799.3441 24 hour 3-5 day Company/Customer: L&K Environmental Project Name: tJ 1 Address: 9851 Castle Ride Cir Collection Date: a L c Address: Highlands Ranch, CO 80129 Customer Number/P.O.: Phone/Fax: 303-912-5016 Collection Address: 2 Customer Contact: Kevin Mackey LKEnvironmental@gmail.com Special Instructions: BULK SAMPLE LOCATION Ace/ Sample Number Re' Sample Material Sample Location SolW 4 i `F'�QOA OA k/ {.V (AUL # /1Y�1 t J.11t1 6x17 �1't t - 'r✓ �CJc,w t Note: Sample collector is responsible for ensuring that all samples have been preserved and prepared to the appropriate and applicable methodology. If package has sustained damage during transit, notify collector and shipper. Turnaround time begins upon receipt of sample (s) by laboratory. Cardno ATC will not be responsible for errors or omissions in calculations from inaccuracy of original data. CHAIN OF CUSTODY .. . •� s.M' r'� ��� � �r rcr��d�� r,,�•������ �..�007AM RFA ■ L&K Environmental Inc Tax ID#: 47-1318090 9249 S. Broadway #200-275 Highlands Ranch, CO 80129 Bill To ServiceMaster Fire and Water Restoration 3250 S. Zuni Street Englewood, CO 80110 Invoice Date Invoice # 7/2/2019 3748 P.O. No. Terms Project Kuntz Net 30 Kuntz- 3244 Taft Quantity Description Rate Amount 8 Limited Asbestos Inspection and Report Bulk PLM Samples- Rush 400.00 28.00 400.00 224.00 Total $624.00 PERMIT: ADDRESS: JOB CODE: INSPECTION RECORD Inspection online form: http://www.cl.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS Do, n �+ 1� �l ,% �. l / /1. `• i 4zf Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous �-- Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof �-- 410 Final Window/Door 411 Landscape/Park/Planning Inspections from these entities shall be requested one week in advance. For landscaping and parking inspections please call 303-235-2846 For ROW and drainage inspections please call 303-235-2861 For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works 413 Flood plain Inspection 414 Fire Insp. / Fire Protection 415 Public Works Final 416 Storm Water Mgmt. 417 Zoning Final Inspection 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTIC Inspection Type: 7 Job Address: �`'l`l 7 f C ,- Permit Number: ��/'�D �) i C -> ❑ No one available for inspection: Time I�A'� 16YPM Re -Inspection required: Yes No When corrections have been made, call 10�inspection at 303-234-5933 Date: (� Inspecto( DO NOT REMOVE THIS NOTICE 8 ► City of Wheat Ridge Residential Roofing PERMIT - 201707587 PERMIT NO: 201707587 ISSUED: 09/22/2017 JOB ADDRESS: 3244 Taft CT EXPIRES: 09/22/2018 JOB DESCRIPTION: Residential Re -roof to install Malarkey asphalt shingles - 36 sq Pitch = 4/12 *** CONTACTS *** OWNER (303)304-6049 KUNTZ DAVID A SUB (303)984-7663 Judy Antener 070171 1-DERFUL ROOF & RESTORATION *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 18,000.00 FEES Total Valuation 0.00 Use Tax 378.00 Permit Fee 331.10 ** TOTAL ** 709.10 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridg Residential Roofing PERMIT - 201707587 201707587 ISSUED: 09/22/2017 3244 Taft CT EXPIRES: 09/22/2018 Residential Re -roof to install Malarkey asphalt shingles - 36 sq Pitch = 4/12 I by my signature do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�ppermit. I further attest that I am le ally authorized to include all entities named within this document as partes to the work to be perf=nyd and that al wgrk� to b pe rmed is disclosed in this document and/or its' accompanying approved plans and specifications. RcAr� SOture of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180. days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and rocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 5ignh4,,�te,Ouildi jgmuct�4j Date REQUESTS MUST BE MADE BY 11:59P�NY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 1 1-17 Dane Lovett z 0�o 7V?,) From: no-reply@ci.wheatridge.co.us Sent: Tuesday, September 19, 2017 1:00 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application `'----� Follow Up Flag: Follow up Flag Status: Completed 77-3 Residential Roofing Permit Application c This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. �,- For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Z)L Property Address 3244 Taft Ct Property Owner Name Dave Kuntz Property Owner Phone 303-304-6049 Number (enter WITH dashes, eg 303-123-4567) 69 4�0q, � -0 Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed 17-0205 Kuntz.pdf Contract CONTRACTOR INFORMATION Contractor Business 1-derful Roofing & Restoration Name Contractor's License 070171 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) 303-984-7663 9858 W Girton Dr Contractor Email Address 1derfulcolleen@gmail.com Retype Contractor Email Address DESCRIPTION OF WORK 1 derfulcolleen@gmail.com TOTAL SQUARES of 36 the entire scope of work: / Project Value (contract18000.00 ) value or cost of ALL materials and labor) i Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or No Pitched roof (2:12 pitch or greater) 70 both? (check all that apply) What is the specific pitch of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: Type of material for the PITCHED roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) 4:12 36 Malarkey Windsor Asphalt Re -Roof House SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to 71 submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Colleen Jacobsen Email not displaying correctly? View it in your browser. 72 1155 Kelly Johnson Blvd., Ste 111 Colorado Springs, CO 80920 Phone: 719-636-1332 Fax: 855-696-7776 DERFUL ROOFING RRESTORATtDN PROPOSAL FOk Name: _ I --- Job Address _ City, State, Zip: (J' D Phone:�- Mailing Address: (If Different) Email Address: � i , c� k i e% '► �' ` C �� Best way to contact: J Tear Off and eaves are open or closed. J Inspect Decking: Deteriorated existing decking replaced at cost of $ Per Sq. Ft. Homeowner will be notified if any damaged wood is found during tear off. J Install ice shield on eaves and in valley(s) J Install drip edge Color J Install underlayment J Recover roof with J year manufacturer warranty. J Shingle manufacturer color J 6 Nail every shingle J Install ridge style J install pipe jacks J lead jacks J swamp cooler J Step flash sidewalls Jstep flash chimney J step flash skylight J 1-Derful Roofing & Restoration will provide general liability insurance of at least $2,000,000 and Workers Compensation of at least $500,000 J Cleanup and haul of roofing debris —J Clean out gutters J Magnetic sweep of surrou ing area J Clean around landscaping J All required Permits fu s y 1-Derful Roofing & Restoration - to be reimbu pony J 1-Derfutntilatin#q fingJ Curre Recommended J of Proposal Date: 5 31 - / ? This proposal may be withdrawn by 14Dedul Roofing & Restoration if not accepted within 30 days from the above data. SUBMITTED BY 1-DERFUL R 1-Derful Rep: �d►S Cell Phone: Insurance Company: Adjustor InformatiQW. D Policy Number: Claim Number Ji Gutters: color Outlet J Siding: J Extra work Special instructions: 1-derful Roofing and Restoration shall hold in trust any payment received from you until 1-derfui has delivered roofing materials at the site or has performed a majority of the roofing work on your property. $ Ar dO deductible to be collected at time of ri de Cry. $initial total claim amount as of _LIi120If f�, This price is subject to supplements/adjustments. Roof work to be completed within 21 days of final insurance approval and mortgage endorsement* omeowner's Signature JINNSCE ty Ow r is /Is not intending to make payment from the proceeds of a property and casualty insurance policy. AI Lo E AGR ntEaTIf so, homeowner must read and sign below. retain I Roofing 6 Restoration (contractor) to repair/replace the damaged or entire portion of the property described on this contract tondngem upon the oontrectm obtaimnp my insurance proval and payment to hove said work Completed. It is agreed that the contractor is empowered to contact my insurance Carrer and to mast with their represergathro In Orde to nogoiate ee ame cost of the repair or replacement of the damage to the above property. upon the insurance comer agreement with the contractor and the down pay-- behrq made the work wtn be adod~ n on a first in first out be" In ate event that the insurance carrtar felts to negotiate in a fair and reasonable manner, the contractor shalt riot be hold liable and this &Woven nt win be void The contractor wig release the complete go to the Commissioner of Insurance at the cutuomer's request. Insured out of pocket expense will not exceed the Insured (purchaser) policy deductible for the wok agreed upon between the insurarce carver and the contractor insured also agras, iso provide ag ens ycuwary doarmOr"bon for the claim (including doWmantation to facilitate payment from Insurance carrier and/or mortgage holder). The contractor reserves the right to file Tor auppiam*r4W dairy din b rreterlaf angor labor kxxeases dor to a abrm a nvironmem or to tnsunance adiuder's mistakes, arrors or omissions. Uwe agree by signing above to alt the continsat condtbon$ on both the host and b*ck of this ograwniant i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Ll 00(' n a Job Address: 3 -a Ll L1 Permit Number: -D o r -7 Q -7 S-c;� -2 Wo O r, J i- ,--e4- `Po i 161 Sf� C D /1 ❑ No one available for inspection: Time 13 - ) S- &PM Re -Inspection required: @)No When corrections have been made, call for re -inspection at 303-234-5933 Date:_1 1 a I `2 Inspector: --T-b DO NOT REMOVE THIS NOTICE 1a �1 i �.,. CI tv, 01t.MI AT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 E - /I I ci Job Address: -r 4- C Permit Number: -0 0 ► -a o -2 s- S -7 S o -*1- C. 4- tclr4rF _ i"la l ❑ No one available for inspection: Time i =9 AM M R6 -Inspection required: Yes I&o When corrections have been made, call for re -inspection at 303-234-5933 Date:-/ o Inspector: Tb DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 306 / �/ M 1 6 Job Address: 3 �,y y To jCt G f' Permit Number: 2-0170 7 Se/ ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When correcf'ons have been made, call for re -inspection of 303-234-5933 Date: / 7 -Inspector: DO NOT REMOVE THIS NOTICE .`" 1 City of'Wheat Ridge -rr Residential Rooting PERMIT - 101263 ?ERMIT NO: 101263> ISSUED: 05/17/2010 70B ADDRESS: 3244 TAFT CT EXPIRES.: 11/13/2010 DESCRIPTION: Reroof ': 37 sqs. * ** CONTACTS * ** >wner 303/433-6525 Jeff Wylde 4c 952/915 -7200 Paz'Sela 09 -0256 Sela Roofing �* PARCEL INFO ** 'ONE CODE: UA "USE: UA SUBDIVISION:`. 0692 :`BLOCK /LOT #: 0/ E* FEE :SUMMARY ** ESTIMATED PROJECT VALUATION: 11,800.00 FEES Permit Fee .272.10 Total Valuation .00 Use ;Tax 212.40 3 ✓� ** TOTAL ** 484.50 w '_onditions: S nails per shingle .`is required. Ice dam membrane is required from eave edge to v inside exterior walls. Board sheathing with any gap greater than 1/2 - equires panel sheathing overlay on entire .`roof. Sheathing inspection is s / /lu. �Uil.xa000L slid. i .l- ..pzuviue.: lauuc,i Lu.i iiiaycu�i�uo. ctions that cannot be performed due to inclement weather must be '. to 8:30 a.m. on the day of inspection or a re inspection fee d. i oy uiu iwae Ii.: u,o .a I'..— alcuL —u vi -1 -...... --- and allegations made are accurate; that I have read and agree to abide by all conditions printed on this I assume full responsibility for compliance with the Wheat'. Ridge Building Code - (I.B.C) and all other Be Ordinances, for work under this permit. Plans:: subject to field inspection. for /owner r date ssued in accordance with the provisions set forth in your application and is subject to the laws of the and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable City. > City of CO W heat�d. Date: MMUNITY DEVELOPMENT Plan # Building & Inspection Services Division Permit # 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application ErOperty Ad e 31�cr U C4- Property Owner (please print) Je-g Lx1 e Phone: 30 5 � 5' Mailing Address: (if different than property address) Address: City, State, Zip: SERA 15 ooFilL)G Contrac : Contractors City License #: 0 - Oa5Cfl Phone: Electrical: Plumbing: Mechanical: City License # City License # City License # �Descrtptio'n of�wor -,kt� Contract Va ue: ��. `�C�C� T $ I t�, R00 Review Fee (due at time of submittal): Squares 3 ? BTU's Gallons _ Amps Sg Ft. $ 413 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the properly to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: 16Z — 0 SEN ST SIGNATURE: ME`F,�P'iTy' DATE: 5 - 1.P —/() 1 Bldg Valuation $ COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number Date 77081 5/15/2004 Property Owner: JEFF WYLDE Property Address : 3244 TAFT CT Contractor License No. : 17875 Company : Coffman Electric, Inc Phone: 433-6525 Phone: 420-1516 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Rid9e Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (O W N ER)(CONTRACTOR) Use Description : RUN CIRCUIT FOR HOT TUB. SET OUTSIDE GFCI OUTLET _ ~±4 BUILDING DEPARTMENT USE ONLY Zoning Comments: SIC : Sq. Ft. : Approval: Zoning : Bliilding Comments Approval : bublic V1lorks, Commentsr" Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : 17875 Plumbing License No : Mechanical License No : Company :Coffman Electric, Inc Company : Company : Expiration Date : 2/28/2005 Approval : OKIKS Expiration Date : Expiration Date : Approval: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur applicafion and is subject to the laws of the Slate of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of lhe City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 tlays. (3) If this permit expires, a new permit may be acquired for a fee of one-half lhe amount normally required, provitletl no changes have been or will be made in the original plans and specifcalions and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be tlone that will change ihe naturel flow o( water causing a drainage problam. (5) Contractor shall nolify the Building Inspector hventy-four (24) hours in advance tor all inspections and shall receive wntten approval on inspection card before proceediing with succassive phases of the job. (6) The issuan mit or t f drawings and specifcations shall not be conslrued to be a permit for, nor an approval of, any violation of the pmv ' s uild' des or any othe`rDrdinance, law, mle or regulation. Construction Value : $575.00 Permit Fee : $34.52 Plan Review Fee : $0.00 Use Tax : $0.00 Total: $34.52 Chief Building Inspector Please sign Terms and Conditions on reverse side of page. May-.13- 74 15v 43 P'aperty fJwner PrCperty AddreSS C intractcs Lir,ense Dda. clamp4ny 7.71NNF R-f; ( N i RAC'`OR $iGNATUF t herMurt!. I thai the selbarmc dertances proposad Dy thia penn@ appiieation are accunta, ann da ia; Ou 'ata appii ab4e yqrqiAara:as. ruka or regulations of the City of Whes1 Rwfge m ~ _cvena~=ts ~i, ;ampnts ar restrichinr:gof racord: lhat ail measuraments ahown, anC a4agetions a.i~ c nate; ms i havR rsad srvtl agrce to e6Wa by all condrtlom prlnletl on this ai n=ai u• , a (J tha! I a asurna MulE reyponsibiliry.{e~ compliance wRh Ihe Wheat Ridpa BuGdiig anc afl o ner aqpr!~cabk Whrlat Ry~e oralnancee, for work under tnis oeerna_ 70+3I. ~7.~~j Ji".,NEi),.;CCVTi2A~^,T3R)5OINEDjr A7E~-.a P_O1 w 1 R-11r uIvIaivn - LSS-2855 ' OF WHEAT RlDGE D Q~, f YEST 29TH AVENUE i// T RIDGE, CO 80215 AppLIUATla N E pF UNOER5TANDING ANp AGREEMENT Phone . % 13~~ Phone E4R; TIUCtlOt1 VaIJP `77 Permit Fee Use Tax USe : CJes ,,rt;,ti ~n : L i f l L'C X BUILDftJG DEPARTMEN7 USE ONLY ~M SIC gq %pprov; d : ~ Zonin ) pprova . pprova ' ; t:.;r.;`.u,.^.,3 cy Roaf Stones : R:sidential Uniti Elactntai i i ense N~ Wumpanj Expirat;:r C ate _ %.enrov3l . ~ {I) 1b56<ttilWitlfv *d10 Fm7nmh ny an] Bu Idinq Y-? T~t~ tll shatl BM ve a 9 RI C]I !Yf tIN yl pp yqj pl 0i Il;hr=1!ErtulaxF!ye!.aIM a;,o-,ali anf aetl 1PaciAc e..a!ds sne(l)yrtit.1u11 [4! 43wCk!linymonxl~t 14} Cv+t'aq rshstrnppYph o!xnc]i ;9vnthew aeu (ni TI,CridLLltit4(iPfRel, 0101 - bu bmq todr, ar ar Plumbing License No Company: Mech anical License io, Company : Expiration date : Expir 3tion Date Approval : ARPtt val : 'M TO PrONIbl°"S sN WA r yoDUt acWlntion m6 b wDjw m rM Lawa of g f 51a~ W Colersda . it 0.iCp~ Cok!1MO a MY oiner avollcable aOMancaa ai tl+e Giry . f mthe Zoning uMOruW n em commencetl wMin ersry (80) arys hom iaew CNe a(0) the :uildmq autnolxed i: ,sce!qetl or be bWwrM for A tee o! arli Me ampint rwmullY r6Quaed. pbvitled rq c'pnpmf hAVe Deen a: ! Ou:Ipmabn v abaMOnmant nas not eaceW W one (t) ear it cnan es er d i! M be rt We ir 4he y . p e rtu a a euspena ■d tor t narv pertntt, i a aDintlonxn: N wil tlimpe IM naNrW fww pf wan+uualny a O~am+ge prpbaem. ~r twanty.hWt 11i) IwvS in sOv~nce im aM insO~Ons anC fhiN ~w ilt ! . en apprjvd on i!es. he inh I o tlta+lfts MM SWJkatlont AtW I n l6 -0on cutl bcfire a e C01341Md W W i CeRind hf, nOf in ApCtwil D?, anYv Mf, IpN. NM Dt ItqUlibOn . . abOn 0!M aroNlWn! .w C llti~ ~ DEPARTMENT OF GOMMUNITY DEVELAPMENT 7500 WEST 29tn AvENUE BUILDING INSPECTION DIVISION PERMIT N0 M91II17510 237-6944 Ex7. 255 P.O. Box 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALIO ONLY WHEN SIGNED BY THE CHiEF BUILDING INSPECTOR ANC RECEIPTED BEIOW. APPLICATION FOR MISCELLANEOUS PERMIT JOBADDRESS OWNER CONTRACTOR~~-~' ADDRESS c~ - Q , PHONE CDY ESE~L~~a ZIP CODE CONTRACT R CE $ ~ F;.O IPQCODE ~ PHONE 2 ~1,?':1g,-,':>_ LICENSE NO. DATE / 1. TVPE Ground U Woll❑ Proiectinp❑ OtMr 5 a D Feeo 2. MATERIAL Tolcl Squon Fee1 SIGN$ 1 ILLUMINA710N Yes❑ No❑ Typs Elxf. Parmit No. 4. SET BACK FROM PROPERTY LINE N _ S_ E _ W Zone_ ApprwW,ZOne Inapeotor (Speeify which ia front) ❑ ❑ ❑ ❑ DisoDDrovad 1. TYPE Solido Mon Thon BO% ODSn❑ Lost Than 80% Open MATERIAL nt Hei FENCES Q 3. SET BACK FROM PROPERTY LINE N _ 5_ E _ W Zmo_ Apprwd,Zorn Inspeetw (Specify whith ie front) ❑ ❑ ❑ ❑ pieopprovad I. - OTHER 2 3. DRAW SKETCH OR SHOW BELOW, THE FENCE,SIGN,OR OTHER STRUCTURE,GIVIN3 DISTANCES FROM PROPERTY LINES (SETBACKS OR PROJECTIONS INCLUOED) SPECIFV NORTH STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TPADJOINING HOUSES, STREETS, AND PROPERTY LINES; ON IRREGULAR LATS, SHOW LEAST DISTANCE TO PROPERTY lINE5,N0T MAXIMUM OR pVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 180 DAYS FROM THE DATE OF ISSUANCE IF WORK IS NOT STAHTED WITHIN THAT TIME. I ELECTRICAL PERMIT STATE LICENSE N0. PLUMBING PERMIT STATE LICENSE NO MECHANICAL PERMIT ALUMINUAIWIREUNDERS12EBILLEGAL FLOOR BSM IST 2ND 3RD 4TH N0. FUEL:ChcJsOrrCwsdlAOpon~COyElxSola NO. WATER CLASET FORCED AIR - BTU TEMPORARY METER WASH BOWL HpT WATER - BTU NEW SERVICE - AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIH CONDITIONING-8TU LIGHTING SINN OTHER HEATING GARBAGE DISP REFRIGERATION SVSTEM POWER SUB-CIFCUITS WATER HEATER Reiri srant Group UTILI7Y(RANGE,DISPoSER,ETC.) AUTO. WASNER Pounds CMr e FIXTURES DISH WASHER AUTOMA7IC SPRINKIER SYSTEM WIRING MOTOftS 8 CONTROLS FI,DOR DRAIN EIEVATOR SIGNS URINAL TRGNSFORMERS B RECTFIERS SEWERS ADDITION 70 OLD WORK OTHER MOTORS OVER I HP TOTAL FI7(TURES ~ REMARKS I hareby acknowledae ihat tnis aoviica- tion n correci and undeistond inoi I connor start Inis projed unril tnis opoli- cotion if opproved. I sholl comply wifh tM lowa o1 the Stote of ColornEO and ro ths Zoninp ReQulahons ond Bmldinp Code ofthe Cify of Wheaf Ridqe. Any violation of ihe above terme will cause immediate revocation of tnis vermii - PERMIT FEE g 0_Pj USE TAX 4 o TOTAL FEE $ pj APPROVED C~1~ DISAPPROVED CHIEF BUILDING I SPECTOR,City of Wheat Ridpe Date Issued NOT VALID UNIESS RE ,EFt (l u `f0 ';L x ~7-~,, ii 'L CALL 237-8944 EXT. 255 24 HOURS IN ADVANCE FORINSPECTIONS 4eoreceil. siW~.sM,.