Loading...
HomeMy WebLinkAbout3760 Vance StreetSCOPE SYNOPSIS THIS SHEET: • COMBINE EXISTING RESTROOMS INTO ONE ACCESSIBLE RESTROOM; NEW FIXTURES AND FINISHES THROUGHOUT. • NEW ACCESSIBLE DRINKING FOUNTAIN TO REPLACE EXISTING WATER STATION • ADD MOPSINK & BACKFLOW PREVENTER IN SMALL JANITORS CLOSET. I I I HY ll --City of CQMMUNI'IY UEVKOI'MEM APPROVED Reviewed far Code ComOHanee Steven Peck 07/22/2021 Plans EXeminer Date ce opamitJu;bmep}walo%ury wionmb .wYamp 9w' 4M1, Mew 1MGM1mamvM swan r., m mPr.w^a 0mw b ww11nbaabn.aM. E,MWM or. w Nna ba..w. a M. on,I,w mf x wxa REVISION WALLS AND PARTITIONS WITHIN 2 FEET OF SERVICE SINKS TO HAVE A SMOOTH, HARD, NONABSORBENT SURFACE NOT LESS THAN 4 FEET ABOVE FLOOR PER 2018 IBC 1209.2.2 ALL WORK SHALL COMPLY WITH 2018 IRC 2018 IBC 2018 IECC 2020 NEC CITY OF WHEAT RIDGE AMENDMENTS FIRST FLOOR EXISTING/DEMO PLAN SCALE: 1/4" = V-0" ® KEYED NOTES 1. NEW ACCESSIBLE WATER CLOSET, TANK, PROMDE ACCESSIBLE GRAB BARS. 2. NEW ACCESSIBLE LAVATORY, WALL MOUNT. PROMDE ACCESSIBLE FAUCET HARDWARE AND PIPE CEDER. AMERICAN STANDARD LUCERNE WALL -HUNG MTREOUS CHINA AOA COMPLLMR OR EQUAL. 3. NEN MOPSINK & CLOSET AREA. PROVIDE 2468 DOOR WITH PASSAGE LATCH AND SHORT SND WALL AS SHOWN. PROVIDE 6%6X04 EXHAUST GRILLE AT CEIUNG & ATTACHED TO BUILDING EXHAUST TRUNK M 04. PROVIDE NEW I' REDUCED PRESSURE BACKROW PREVENTER ABM MOPSINK. CONNECT TO }' EXISTING BUILDING SHUT OFF VALVE (98) `M 1' PIPE, WHICH SHALL BE CONCEALED IN SLAB OR MARKED 'NON -TAPPABLE. PROVIDE NEW A -EASE LIGHT FIXTURE AT CEILING W/ MOTION SENSOR: CONNECT TO EXISTING RESTROOM CIRCUIT 4. REUSE EXISTING RESTROOM DOOR IF POSSIBLE OR PROVIDE NEW; PROADE NEW ADA l£4ERSET W/ BATHROOM PRNACY UATCH. 5. NEW SND WALL, 3 r 25 GA METAL OR 2X4 TIMBER STUDS, r TYPE wXw GWB PURPLE BAWD / MOISTURE RESISTNR. 6. NEW BI-I_I DRINKING FOUNTAIN, ACCESSIBLE, WNL MOUNT. RE -WIRE EXISRNG GFCI RECEPTACLE THIS AREA FROM OLD DEMOLISHED DRINKING STATION. 7. FINISH NOTES: 7.1. NEW FLOOR 111E AND FIE CEDE REQUIRED SE OF DEMOLISHED WALL BETWEEN OLD RESIROOMS. INCLUDING AT DRINKING FOUNTAIN 1 7.2. NEW TLE BACKSPIASX REQUI ED 48' P PLUMBING FIXTURES PER CODE. 7.3. NEW SEMI -GLOSS PNM REQUIRED ALL SURFACES INCLUDING CLG IN RESTROOM. EXISTING RESTROOM GWB CLG SHLLL REMAIN. BE PATCHED AS REQUIRED, AND BE PAINTED. 7.4. PROMDE VANITY MIRROR, AUTOMATIC PAPER TDWEL DISPENSER, TWO NEW CAN LIGHTS IN CEILING, NEW MOTION SENSOR WALL SENSOR +"' AT LEFT OF 0.WR WHEN LEAING RESTROOM; RE1SE EXISTING RESTROOM ELECTRICAL CIRCUIT. FIRST FLOOR PROPOSED PLAN SCALE: 1/4" = 1'-0" ISSUE: BUILDING DEPT. ISSUE IQ1&20 R1 CITY COMMENTS 01.10.20 R2 FELL) CHANCES 08.16,21 EUFMERM Z as Q Z J Q J a 0 0 J w Q 0 y O L) V W F- go DL V erc M Fm = p 2 � � U w Q ENGINEERINGCOMPANY �e W= W p Q� W N 7Wa�CE W F_ _ OZ NU W 3z M a Z O o W {i R W u rc `0 ENGINEER DPN KING, P.E 4900W.9hfue Daeer,MS0212 3?.8JDG105 ENGINEERSETAMP 14 L/C .. p8pD0 �. ,..too O µ11 B••. � O 'a17.02.� :<40380 z +.o ni % ..........:. /OVAL CHECKED BY DIRK DRAWN BY DIRK REND AMESPROJECTNUMBER 19358.2 SHEETWJ. Al repNft wheatndae To: C Mmaee o Mi co us subjee: amine win: subm�mc kmisnn m remm Mpiionon om: welnewsy, Jure Jo, 2021 10:42:52 am Revision to Permit Application Permit Number 202002172 assigned to project PROPERTY INFORMATION Permit Number 202002172 Property Address 3760 Vance at Property Owner Name Daniel Reno King Property Owner Phone 3038005105 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email dking@mnojames.com Address CONTRACTOR INFORMATION Contact Name Eric Zamora Contact Phone Number (720) 385-7329 (enter WITH dashes, eg 303-1234567) Contact Email Address aria m@hotmail.com Retype Contact Email erimum@hotmail.com Address DESCRIPTION OF WORK Detailed Revised New mopsink originally proposed within new Accessible Scope of Work - restroom; relocated to inside existing janitors closet Provide a detailed description of the change in scope of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc Engineer Letter (if Field trot completed. applicable) Additional Documents Field not completed. on Letter Size Are plans or No documents locked for editing? Construction Plans 19368 3760 VANCE R1 0616: scanned on 11"x17" or larger Additional Project $o.00 $0 VALUATION Value Only add what APPROVED SP the revised scope of work is valued at. Attach City of Wheat EllCrfO" pavmem FO°° otlf Ridge Electronic Payment Form - ""DO NOT ATTACH A PICTURE OF A CREDIT CARD" SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Submitting Daniel King Revision Email not displaying wmadly? View it in wur browser. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Comm. Tenant Finish PERMIT - 202002172 202002172 3760 Vance St Combine two existing restrooms flow preventer, service sink, restrooms. Sq ft: 75 ISSUED: 10/22/2020 EXPIRES: 10/22/2021 into single accessible restroom, add back accessible drinking fountains on 1st floor ***REVISION*** New mopsink originally proposed within new Accessible restroom; relocated to inside existing janitor's closet *** CONTACTS *** OWNER (303)800-5105 Dan King GC (720)938-1608 ROGER BEAVER 202011 BEAVER CONSTRUCTION CONSULTING SUB (720)598-2255 JAMES TAPEY 202289 A NEW ERA MECHANICAL SUB (303)650-6050 KATHLEEN MURPHY 130100 JULES PLUMBING CO. OF DENVER SUB (720)737-8030 CLAYTON LUC 140136 BOSS ELECTRIC LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 520 / Office; 0 BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 12,000.00 FEES Total Valuation 0.00 Plan Review Fee 153.40 Use Tax 252.00 Permit Fee 236.00 ** TOTAL ** 641.40 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IBC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. � ► 44" City of Wheat Ridge '/� Comm. Tenant Finish PERMIT - 202002172 PERMIT NO: 202002172 ISSUED: 10/22/2020 JOB ADDRESS: 3760 Vance St EXPIRES: 10/22/2021 JOB DESCRIPTION: Combine two existing restrooms into single accessible restroom, add back flow preventer, service sink, accessible drinking fountains on 1st floor restrooms. Sq ft: 75 ***REVISION*** New mopsink originally proposed within new Accessible restroom; relocated to inside existing janitor's closet I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 10/22/2020 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Plumbing Subcontractor This form must be completed & signed by the PLUMBING SUBCONTRACTOR performing plumbing work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: a General Contractor: C&O LZ XU FORM WILL NOT BE ACCEPTED WITH MISSING INFORMATION � Company Name: �UL S1 �L/MR%,�contact Phone #: 36 --euro--62 Wheat Ridge Contractor License #: i D 0 (required field) State License #: t) b lI f Master License #: Ad 0 as i:7 9 � �d 'm " � , , 1 14 t1,A,01141-,� Printed Name of Authorized Agent Signature of Authorized A nt Date 0 Occupant Name Address: Permit Number: Plan Type Pass Fail N/A West Metro Fire Protection District 433 S. Allison Pkwy, Lakewood, CO 80226 (303) 989-4307 Molass Building 3760 Vance Street Wheat Ridge, CO 80033 N/A Original Contractor: InspectionType Inspection Date Inspected By: Daniel King Plan Review - Tenant Improvement 10/15/2020 Jerry Sauer 303-989-4307 Plan Review General [x] [ ] [ ] G.30 REVIEW Yourplans have been approved. Follow this Link and the steps below to reconcile FEES: your in voice. 1. Select "Life Safety" under the Bill Type options 20101514507 2. Enter invoice number 3. Select the associated permit type from the "Permit/Fee Type" drop down menu 4. Select "Construction Permit" in the "WMFR Acct#" drop down menu 5. Enter the Job Address 6. Enter payment amount of $258.00 7. Select Pay by Card to complete the transaction Once completed, you are no longer required to send us a copy of your payment receipt. It is your responsibility to retain a copy for your records. Your payment will be processed within (1) business day after it was made and has posted to our Heartland account. Once payment has been confirmed, a link to the reviewed plans will be emailed to the contact listed on the permit. Please be sure to check your junk mail folder if you're anticipating a link email from our office. Your plans have been approved. Refer to the area above for further relevant information. West Metro Fire Rescue Life Safety Plan Review Desk Status: Approved EARTH ENERGY ENVIRONMENT CORP 5366 LLongmont, °CO 80050044 Local: 303.478-0922 Industrial Hygiene and Environmental Consulting December 8, 2019 The bones are hot. Is it new or old? Mr. Dan King, P.E. CIg file in 3rd floor Reno James Engineering corridors are hot. 4900 W 29a Ave, Denver, CO !L 303.800.5105 Subject: Asbestos Inspection Report -3760 Vance Street, Wheat Ridge, CO Dear Mr. King: Earth Energy Environment (E3) is pleased to submit results for the bulk sampling at the commercial property ("subject property") located at 3760 Vance Street, Wheat Ridge, CO. The sampling was conducted on December 5, 2019. The sampling was conducted for the purpose of determining if asbestos containing materials are present in the building. For the survey, samples of surfacing material were collected using the EPA random sampling protocol outlined in the EPA publication, "Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials" ("Pink Book", EPA 560/5-85-030a, October, 1985). City of LIMITATIONS Wheat Ridge Building Division This investigation was conducted and the report prepared solely for property owners. No warranties for other uses are applied and intended. Evaluations of conditions at this site were made Survey Report 2 1 P a g e from a limited number of observation points and conditions cannot be warranted at non - observation points or non -accessible areas. The sampling included the suspect asbestos containing materials based on visual observations and discussion with the property representative. Interpretations and conclusions made in this report that pertain to the asbestos are based solely on results of independent laboratory analyses of the samples taken at the property at the date and time indicated. E3 has no control over such testing and analyses and, therefore, disclaims any responsibility for errors or omissions arising there from. INSPECTION RESULTS E3 sampled forty-six (46) homogeneous areas, as summarized below. E3 collected at least the minimum number of samples for the homogeneous area necessary to meet all regulatory requirements. Homogeneous Areas (HA): Homogeneous areas were selected from the building materials observed during the site inspection. The homogeneous areas sampled during the inspection are listed below. HA Description FriabilityCondition Material Potential for Disturbance 1 Exterior Brick Mortar Friable Good High 2 Block Coating (stairwells) Friable Good High 3 Unit 200B Walls Friable Good High 4 3rd Floor Hallway Walls Friable Good High 5 Unit 200B Bath and Hallway Friable Good High 6 3rd Floor Ceiling Tiles (newer) Friable Good High 7 Hall Ceiling Tiles (older) Friable Good High 8 Front Entry 1st Floor Walls Friable Good High 9 Unit 301 Walls Friable Good High 10 3rd Floor Stairwell Ceiling Friable Good High 11 Cove Base Glue Non -Friable Good High 12 3rd Floor (above tiles) Joint Compound Friable Good High 13 3rd Floor Stairwell Wall Paper Wall Friable Good High W City of eat Ridge Building Division Survey Report 3 1 P a g e 14 Unit 100 Walls Friable Good High 15 Roof Mastic Non -Friable Good High 16 Unit 200A Brick Coating Friable Good High 17 1st Floor Storage Room Walls Friable Good High 18 Unit 100 and Unit 101 Walls Friable Good High The laboratory separated and analyzed individual layers within each sample, if present (see Attachment A). Table 1 provides a summary of the homogeneous areas, associated samples numbers, area description, classification, material type, and laboratory description of the sample makeup. Table 1. Sampling Results. ity of Wheat Ridge Building Division Classification Sample Area Asbestos HA / AHERA Description No. Description Content Category Exterior Brick Misc. No Asbestos 1 1-2 A Off white mortar Mortar Materials Detected A Off white/multi-colored Block Coating Surfacing granular material No Asbestos 2 3-5 (stairwells) Materials B White block filler w/ Detected light gray paint A Off white compound w/ light beige paint Unit 200B Surfacing No Asbestos 3 6-8 B Off white compound w/ Walls Materials Detected cream paint C White/tan drywall A Off white resinous 3rd Floor material No Asbestos 4 9-10 Misc. Materials Hallway Walls B Yellow wall covering w/ Detected off white paint A White paint Unit 200B B White joint compound 2% to 3% 11-13,5 Mises Materials Bath and C White compound Chrysotile 39 «5„ Hallway D Off white tape Asbestos E White/tan drywall 3rd Floor 14-15, No Asbestos 6 Ceiling Tiles Misc. Materials A White/gray ceiling tile 41 Detected (newer) Hall Ceiling IMisc. Materials A White/off white ceiling 4% Amosite 7 16 Tiles (older) 1 "5" tile Asbestos ity of Wheat Ridge Building Division Survey Report 41Page .ry of Wheat Ridge Building Division Front Entry A Off white compound Misc. Materials 2% Chrysotile 8 17-19 1st Floor B Brown/offwhite paint 5 Asbestos Walls C Offwhite/tan drywall Surfacing A White joint compound Unit 301 2% Chrysotile 9 20-24 Materials B Off white tape Walls Asbestos "5" C Off white compound 3rd Floor A Off white paint Mises Materials 2% Chrysotile 10 25-26 Stairwell B White compound 5 Asbestos Ceiling C Offwhite/tan drywall Surfacing A Brown adhesive 27-28, Cove Base 2% Chrysotile 11 Materials B Off white/tan drywall w/ 40 Glue Asbestos "5" off white paint A Off white tape 3rd Floor Surfacing B Off white compound (above tiles) 2% Chrysotile 12 29-30 Materials C Off white joint Joint Asbestos "5" compound p Compound D Off white/tan drywall A Off white/multi-colored 3rd Floor Surfacing paint w/ a trace of white No Asbestos 13 31-32 Stairwell Wall Materials compound Detected Paper Wall B White/tan drywall A White compound w/ Surfacing gray/multi-colored paint Unit 100 3% Chrysotile 14 33-34 Materials B Off white tape Walls Asbestos "5" C White joint compound D Off white/tan drywall Surfacing A Black tar w/ gray fibrous 4% Chrysotile 15 35-37 Roof Mastic Materials material Asbestos "5„ A Gray granular Unit 200A Surfacing No Asbestos 16 38 ementitious material w/ c Brick Coating Materials Detected off white paint A Off white tape B Gray/multi-colored paint 1st Floor Surfacing 42, 45- C Off white joint 2% Chrysotile 17 Storage Room Materials 46 compound Asbestos Walls "5„ D Off white texture E Off white/tan drywall A Off white/multi-colored Unit 100 and Surfacing paint B White texture 2% Chrysotile 18 43-44 Unit 101 Materials C Off white tape Asbestos Walls «5„ D White joint compound E White/tan drywall AHERA Category "5" = ACBM with potential for significant damage. Ci .ry of Wheat Ridge Building Division Survey Report SlPage SUMMARY AND CONCLUSIONS According to the laboratory analysis of the materials sampled, asbestos was detected in the following material types and areas: • 1st, 2nd, and 3rd Floor Textured Drywall Walls and Ceilings • Cove Base Glues • Roof Mastics • Ceiling Tiles (older style) The Colorado Department of Public Health and the Environment requires any asbestos containing material greater than 1% that is friable or will be made liable during demolition activities be removed prior to demolition by a certified abatement contractor. Any other potential asbestos containing materials identified in the future or during demolition that were not sampled in this, or any other previous survey, should be tested for asbestos content or assumed to contain asbestos before being disturbed. If you have questions or require additional information, please contact me at (303) 478-0922. Respectfully Submitted, EARTH ENERGY /ENVIRONMENT (E3) Arthur Willden, P.E. Engineer / Industrial Hygienist City of Wheat Ridge Building Division Attachment A Laboratory Results Survey Report 61Page City of Wheat Ridge Building Division Reservoirs Environmental, Inc Effective April 02, 2018 Reservoirs Environmental QA Manual Q:\QAQC\Lab\Reservoirs Environmental QA Manual.doc Reservoirs Environmental, lnc_ REI LAB December 06, 2019 Eli Wllden Earth Energy and Environment Corp. P.O. Box 348 Frederick CO 80530 Dear Eli, Subcontractor Number: Laboratory Report: Project #/P.O. #: Project Description RES 451109-1 None Given 3760 Vance Street Wheat Ridge Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 451109-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, by Josh Baker Jeanne Spencer President P:303-964-1986 5801 Logan St, Suite 100, Denver, CO 80216 F:303-477-4275 City of Wheat Ridge Building Division 1-866-RESI-ENV -.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental GA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 451109-1 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3760 Vance Street Wheat Ridge Date Samples Received: December 05. 2019 Effective April 2, 2018 Q AQAQCALABAReservoirs Environmental GA Manual doc Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Priority TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: December 06, 2019 Client L Asbestos Content Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) Brick Mortar -1 A Off white mortar 100 ND 0 100 Brick Mortar -2 A Off white mortar 100 ND 0 100 Back Stairs Block Walls -1 A Off white/multi-colored granular material 25 ND 0 100 B White block filler w/ light gray paint 75 ND 0 100 Back Stairs Block Walls -2 A White block filler w/ light gray paint 40 ND 0 100 B Light gray/multi-colored granular plaster 60 ND 0 100 Back Stairs Block Walls -3 A White block filler w/ light gray paint 100 ND 0 100 Unit 200B Wall -1 A Off white compound w/ light beige paint 6 ND 0 100 B Off white compound w/ cream paint 6 ND 0 100 C White/tan drywall 88 ND 15 85 Unit 200B Frig Wall -2 A Off white compound w/ light cream/multi-colored paint 3 ND 0 100 B Off white/tan drywall 97 ND 15 85 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. City of Wheat Ridge Building Division P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI{NV F. 303-477-4275 www. reilab. com Page 1 of Reservoirs Environmental, Inc. Reservoirs Environmental GA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 451109-1 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3760 Vance Street Wheat Ridge Date Samples Received: December 05. 2019 Effective April 2, 2018 Q AQAQCALABAReservoirs Environmental GA Manual doc Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Priority TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: December 06, 2019 Client L Asbestos Content Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) Unit 200B NW Office -3 Wall A Off white compound 3 ND 0 100 B Cream tape 3 ND 95 5 C Off white compound w/ white paint 3 ND 0 100 D Off white/beige wall covering 3 ND 35 65 E Light gray/tan drywall 88 ND 15 85 3rd Floor Hall Wall -1 A Off white resinous material 3 ND 0 100 B Yellowwall covering w/ off white paint 97 ND 65 35 3rd Floor Hall Wall -2 A Off white paint 100 ND 0 100 2nd FLR South W/C-2 A White paint 2 ND 0 100 B White joint compound 3 Chrysotile 2 0 98 C White compound 5 Chrysotile 3 0 97 D Off white tape 5 ND 90 10 E White/tan drywall 85 ND 18 82 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. City of Wheat Ridge Building Division P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI{NV F. 303-477-4275 www. reilab. com Page 2 of Reservoirs Environmental, Inc. Reservoirs Environmental GA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 451109-1 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3760 Vance Street Wheat Ridge Date Samples Received: December 05. 2019 Effective April 2, 2018 Q AQAQCALABAReservoirs Environmental GA Manual doc Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Priority TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: December 06, 2019 Client L Asbestos Content Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) Unit 200B Bath W/C-1 Not Analyzed per Client Request. Unit 200B Hall Wall (Drink Ft) -3 Not Analyzed per Client Request. Ceiling Tile -1 A White/gray ceiling tile 100 ND 85 15 Ceiling Tile -2 A White/gray ceiling tile 100 ND 85 15 Hall Ceiling Tile (Older Pattern) -3 A White/off white ceiling tile 100 Amosite 4 81 15 Front Entry 1st FLR Wall -1 A Off white compound 2 Chrysotile 2 0 98 B Brown/off white paint 3 ND 0 100 C Off white/tan drywall 95 ND 18 82 Front Entry 1st FLR Wall -2 Not Analyzed per Client Request. Front Entry 1st FLR Wall -3 Not Analyzed per Client Request. Unit 301 (NW Office) A Off white/tan drywall w/ off white/multi-colored paint 100 ND 16 84 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. City of Wheat Ridge Building Division P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI{NV F. 303-477-4275 www. reilab. com Page 3 of Reservoirs Environmental, Inc. Reservoirs Environmental GA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 451109-1 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3760 Vance Street Wheat Ridge Date Samples Received: December 05. 2019 Effective April 2, 2018 Q AQAQCALABAReservoirs Environmental GA Manual doc Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Priority TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: December 06, 2019 Client L Asbestos Content Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) Unit 301 Center Office Wall -2 A White joint compound 5 ND 0 100 B Off white tape 5 ND 90 10 C Off white compound 10 Chrysotile 2 0 98 D White compound w/ off white/multi-colored paint 10 ND 0 100 E Off white/tan drywall 70 ND 18 82 Unit 301 Wall (NE Office) -3 A White texture w/ gray/multi-colored paint 10 ND 0 100 B Off white/tan drywall 90 ND 18 82 Storage Rm Wall -4 A Off white tape 5 ND 90 10 B Gray/multi-colored paint 5 ND 0 100 C Off white joint compound 10 Chrysotile 3 0 97 D Off white texture 10 Chrysotile 3 0 97 E Off white/tan drywall 70 ND 18 82 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 F. 303-477-4275 Page 4 of9 City of Wheat Ridge Building Division 1-866-RESI{NV wwwreilab. com Reservoirs Environmental, Inc. Reservoirs Environmental GA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 451109-1 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3760 Vance Street Wheat Ridge Date Samples Received: December 05. 2019 Effective April 2, 2018 Q AQAQCALABAReservoirs Environmental GA Manual doc Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Priority TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: December 06, 2019 Client L Asbestos Content Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) Center Rm W. Wall (Unit 301)-5 A White compound w/ white paint 5 ND 0 100 B White compound w/ white paint 5 ND 0 100 C White texture w/ gray paint 10 ND 0 100 D Off white/tan drywall 80 ND 20 80 3rd Floor Stairwell Ceiling -1 A Off white/tan drywall w/ off white/brown paint 100 ND 17 83 3rd Floor Stairwell Ceiling -2 A Off white paint 2 ND 0 100 B White compound 8 Chrysotile 2 0 98 C Off white/tan drywall 90 ND 20 80 Cove Base Glue -1 A Brown adhesive 40 Chrysotile 2 0 98 B Off white/tan drywall w/ off white paint 60 ND 55 45 Cove Base Glue -2 Not Analyzed per Client Request. TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. City of Wheat Ridge Building Division P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI{NV F. 303-477-4275 www. reilab. com Page 5 of Reservoirs Environmental, Inc. Reservoirs Environmental GA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 451109-1 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3760 Vance Street Wheat Ridge Date Samples Received: December 05. 2019 Effective April 2, 2018 Q AQAQCALABAReservoirs Environmental GA Manual doc Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Priority TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: December 06, 2019 Client L Asbestos Content Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) 3rd FLR Above Ceiling JC -1 A Off white tape 5 ND 90 10 B Off white compound 5 Chrysotile 2 0 98 C Off white joint compound 10 Chrysotile 2 0 98 D Off white/tan drywall 80 ND 20 80 3rd FLR Above Ceiling JC -2 Not Analyzed per Client Request. 3rd FLR Stairwell (Wall Paper) -1 A Off white/multi-colored paint w/ a trace of white 5 ND 0 100 compound B White/tan drywall 95 ND 20 80 3rd FLR Stairwell (Wall Paper) -2 A Gray/tan drywall w/ beige paint 100 ND 18 82 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. City of Wheat Ridge Building Division P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI{NV F. 303-477-4275 www. reilab. com Page 6 of Reservoirs Environmental, Inc. Reservoirs Environmental GA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 451109-1 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3760 Vance Street Wheat Ridge Date Samples Received: December 05. 2019 Effective April 2, 2018 Q AQAQCALABAReservoirs Environmental GA Manual doc Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Priority TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: December 06, 2019 Client L Asbestos Content Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) Unit 100 Wall -1 A White compound w/ gray/multi-colored paint 5 ND 0 100 B Off white tape 5 ND 90 10 C White joint compound 10 Chrysotile 3 0 97 D Off white/tan drywall 80 ND 20 80 Unit 100 Wall -2 Not Analyzed per Client Request. Rug Mastic -1 A Gray resinous material 100 ND 0 100 Rug Mastic -2 A Blacktar w/ gray fibrous material 100 Chrysotile 4 0 96 Rug Mastic -3 Not Analyzed per Client Request. Unit 200A White Brick Coating A Gray granular cementitious material w/ off white paint 100 ND 0 100 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 F. 303-477-4275 Page 7 of9 City of Wheat Ridge Building Division 1-866-RESI{NV wwwreilab. com Reservoirs Environmental, Inc. Reservoirs Environmental GA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 451109-1 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3760 Vance Street Wheat Ridge Date Samples Received: December 05. 2019 Effective April 2, 2018 Q AQAQCALABAReservoirs Environmental GA Manual doc Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Priority TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: December 06, 2019 Client L Asbestos Content Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) Unit 200A SE Office Wall -1 A Off white/white paint 2 ND 0 100 B Gray/multi-colored wall covering 5 ND 40 60 C Off white tape 5 ND 90 10 D Off white compound 8 Chrysotile 2 0 98 E Off white joint compound 10 Chrysotile 2 0 98 F Whiteftan drywall 70 ND 20 80 Cove Base Mastic -3 A Tan/brown adhesive 100 ND 0 100 2nd FLR Ceiling Tile -4 A White/off white ceiling tile 100 ND 85 15 Storage RM Wall -1 A Whiteftan drywall w/ white paint 100 ND 20 80 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. City of Wheat Ridge Building Division P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI{NV F. 303-477-4275 www. reilab. com Page 8 of Reservoirs Environmental, Inc. Reservoirs Environmental GA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 451109-1 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3760 Vance Street Wheat Ridge Date Samples Received: December 05. 2019 Effective April 2, 2018 Q AQAQCALABAReservoirs Environmental GA Manual doc Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Priority TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: December 06, 2019 Client L Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) Unit 100 Wall -2 A Off white/multi-colored paint 5 ND 0 100 B White texture 5 Chrysotile 2 0 98 C Off white tape 5 ND 90 10 D White joint compound 10 Chrysotile 2 0 98 E Whiteftan drywall 75 ND 18 82 Unit 100 Wall -1 A White compound w/ off white/white paint 5 ND 0 100 B Off white/multi-colored paint 5 ND 0 100 C Off white compound 5 Chrysotile 2 0 98 D Off white/tan drywall 85 ND 17 83 Storage RM Block Wall -1 A White compound w/ white paint & gray granular debris 100 ND 0 100 Storage Rm Wall -2 A Off white/multi-colored paint 2 ND 0 100 B White compound 8 Chrysotile 2 0 98 C Whiteftan drywall 90 ND 20 80 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. Ryan Shilling Analyst City of Josh E. Baker Wheat Ridge Analyst / Data QA Building Division P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI{NV F. 303-477-4275 www. reilab. com Page 9 of § 10 qqe4dt, IMI k\ \ � !� {! § 10 \` qqe4dt, IMI ) \ � - - » `^ / !! ` !(|! ! !■ �\ §|R)G!5< w \` \ � ) \ � » `^ / \ � Building Division l u!!!! ®!!! u ®! ®! n! ■1111 n! u 1111 n!!! n! n ■ n!!!!!!!!!!!!! 111!! 111111111111!! 111■! 1 ■! ■ ■■■■■■■■Y■N■■■■q■NY■■Y■N !11111■!■11111■11111111MEN 0®®9®98980®©®0®BBB88®®®©1MUOUiiQU Building Division V 5 � w� O O � o m vii � ueWeNHI'JY eayl (l) F.Fmen aaa.s :MON n3Hle NO elnLHl s IdWK eeVeaJVe.^o ,c -r. nTeA ftl's p1m In�wuwwO,o m'u.wwola'+auw ' uw.l.,wwmwe i.:wweele.l wur,ww.iwny. wsA� li L i,..I.w.a'we.p.wy wee»y wWwo lelaewlw& I oww.Wnu.eow y. Wweulepw,wn lle.i � '. '6WIef1'LHLS40 N/+3'.IFWwFS'...aeW.tl '. y�II ' ? H13W-pNMJnO IC �S.wPW 'sand MIGI.N'dlel'aV DN ' (UMFW ' Bltlliw '. .WaM..H 'Fwl lana .90 Som'I vaoee - wpa .a.V Vag�ro51 '—W 45M'Nas 'lu^O '-/. Osl YOVI'III-1 VU3HV Ml w�aOwNa rroaw Gwl umwvous wla I I i I I fel ue r5 ` I a ` a W� w a C� S r N 7 n City Of m g o Wph�el!RRid E p N N His Fl ' f7 IOW Cml W !UI q IN ffg IA HI V 10 9 8 F 6 5 4 3 AI BI CI DI E EXISTING BUILDING NOT TO SCALE, LOOKING EAST-NORTHEAST FOUND 3" BRASS CAP IN RANGE BOX 0.75' BELOW GRADE "CITY OF WHEAT RIDGE LS 13212" (1964) NORTH 1/4 CORNER SEC26-T3S-R69W \\� v I 2 40, 0(/ S6��S R r oFOUND NO. 4 REBAR 2.5' BRICK WALL ELECTRIC BOX 32.0' LANDSCAPE MAILBOX C— r U] 3 0 W § � x =z� a 0 µ 9 3 UJ 0 MAP U k' w x Project shall comply with the OZ o INTERNATIONAL BUILDING CODE 2018 International Codes T INTERNATIONAL PLUMBING CODE X a 0 INTERNATIONAL MECHANICAL CODE 2 W °w 0 � � o INTERNATIONAL FUEL GAS CODE o; W 39TH a o o_ F NATIONAL ELECTRICAL CODE ANSI Al 17.1-2009 AMERICAN NATIONAL STANDARD N AVE N O WHEAT RIDGE CO BUILDING SF: z 0 �c PROPERTY 3RD FLOOR: 2693 SF TOTAL: 7343 SF I= ZI CONSTRUCTION TYPE 503: BUILDING QUALIFIES AS VB. 2 STORIES A BOV E G RA DE PLANE= 2 STORIES A BOV E LLJ Lz v � U m SURVEY EXCERPT NOT TO SCALE SET P/C F G 40" 54" MIN 42" MIN 36" MAX ro H 36" MIN 36" MIN ,v 12" MIN 12" MIN 14"-1z" L__1 cD o c° X r7 r7 GRAB BAR DETAIL FRP 48" TALL AND24" MIN 6" CERAMIC TILE COVE BASE 24" PAST FIXTURES CERAMIC TILE FLOOR FINISH REQ'D ACCESSIBILITY DETAILS NOT TO SCALE FOUND 3 ;" BRASS CAP IN RANGE BOX 0.60' BELOW GRADE BASIS OF BEARING: "CITY OF WHEAT RIDGE LS 13212" (1984) N89038'24"E 2633.67'(M) NOS EC T3S4R89RN'NER NORTH LINE OF SEC26—T3S—R69W \ I N+B LLC % 7400 W 38TH AVE 39-261-00-049 OHII OHII N89040'01 "E 150.00'(M&P) oHu FOUND YELLOW PIN & CAP q o _ u"° "UNN LS 37266• OHS 0 1 %� // 14>3 '777/ / i i i�Y 1) / / i �� �" ' DUMPSTER AREA TRANSFORMER 0�1 � i WHEAT RIDGE PARTNERS LLC o"'3715 UPHAM ST j 3760 VANCE ST, 0 39-261-00-047 WHEAT RIDGE, CO / DANIEL BEATON TWO AND A HALF STORY OFFICE BUILDING F W PARCEL ID: 39-261-00-050 O FF: 5448.95 / �F CONCRETE RP: 5479.81 BLDG FOOTPRINT: / 2,370 SF BIOHAZARD SITE AREA: MEDICAL BOX a T 16,050 SF 2.0 OR 0.368 AC t wm wm / LANDSCAPE °T ui a 2.0 / i 4' WOOD / 4 / . 14.,3 4 q CONCRETE - ASPHALT PARKING LOT 6' WOOD S89040'01"W 150.00'(M&P) JENNIFER ANDRES ARROYO 37444 VANCE ST 39-261-00-051 6' WOOD 0.7' - _\­ DEREK & AMANDA GILMORE 3705 UPHAM ST 39-261-00-046 STEEL PICNIC TABLE ANCHORED ON CONCRETE PADS SET P/C N N KI L SOAP DISPENSER TOWELS w w w w X o < J w 1 0 � 0 1 1 � 1 w o I <0 O 8" MIN KNEE CLEARANCE 17" MIN DEPTH MI ON SITE PLANS MUST BE ON SITE FOR INSPECTION ALL Projects are Subject to Field Inspections PROVIDE ADA COMPLIANT PIPE COVER/LAVATORY SHIELD 6" MAX TOE CLEARANCE VICINITY MAP U x Project shall comply with the INTERNATIONAL BUILDING CODE 2018 International Codes Q INTERNATIONAL PLUMBING CODE X Q 0 INTERNATIONAL MECHANICAL CODE Q W °w 0 � � o INTERNATIONAL FUEL GAS CODE o 0 W 39TH AVE 0 F NATIONAL ELECTRICAL CODE ANSI Al 17.1-2009 AMERICAN NATIONAL STANDARD N AVE WHEAT RIDGE CO PROVIDE ADA COMPLIANT PIPE COVER/LAVATORY SHIELD 6" MAX TOE CLEARANCE VICINITY MAP U GOVERNING CODES Project shall comply with the INTERNATIONAL BUILDING CODE 2018 International Codes SCALE 1"=500' INTERNATIONAL PLUMBING CODE 2020 National Electrical Code Q 0 INTERNATIONAL MECHANICAL CODE J W °w 0 INTERNATIONAL ENERGY CONSERVATION CODE Cn INTERNATIONAL FUEL GAS CODE o 0 W 39TH AVE 0 EXISTING BUILDING CODE NATIONAL ELECTRICAL CODE ANSI Al 17.1-2009 AMERICAN NATIONAL STANDARD W 38TH AVE WHEAT RIDGE CO BUILDING SF: 1ST FLOOR: 2370 SF 0 SUBJECT PROPERTY 3RD FLOOR: 2693 SF TOTAL: 7343 SF OCCUPANCY TYPE 302: BUILDING IS ENTIRELY F OFFICE "B" OCCUPA NI CONSTRUCTION TYPE 503: BUILDING QUALIFIES AS VB. 2 STORIES A BOV E G RA DE PLANE= 2 STORIES A BOV E LLJ Lz GRADE PLA NE A LLOWED � U m (l BUILDING IS OVER 10' FROM PROPERTY LINE ON ALL � Cl) SIDES AS SHOWN ON SITE PLAN. NO FIRE RESISTANCE RATING REQUIRED ON EXTERIOR WALLS FOR VB z O = 0_ Ili U Q W U FACE EXISTING NON-COMPLIANT. FIRE SPRINKLER 903.2.4: NOT FIRE SPRINKLERED. OCCUPANT LOAD: BUSINESS 1 PER 100 SF = 74 OCCUPANTS Z a J PATH AND 200' MAXIMUM TRAVEL DISTANCE PLUM BING FIXTURE COUNT: 74 OCCUPANTS = 37 MEN, 37 WOMEN r a sex = W 37TH AVE ACCESSIBLE GRAB BARS AND LAVATORY BEING ADDED TO 3RD FLOOR RESTROOMS. ACCESSIBLE LEVERSEfS BEING ADDED ALL DOORS BEING TOUCHED. ACCESSIBILITY IMPROVEMENTS WELL EXCEED 20% OF VALUE OF PROJECT. W 36TH PL W 36TH AVE W 36TH AVE W 35TH PL GRAPHIC SCALE 250' 0' 250' 500' W 35TH AVE Provide Clean Air Report to Building Inspector at First Inspection to Verify Asbestos Particles are No Longer Present City of ]VcormMW heat Edge APPROVED Reviewed for Code Compliance Randy Slusser 11/03/2020 Plans Examiner Date Validity of oerMN: The issuorste of a PWW or UPP10i of plans speC4katbm and computations shag not be o permit for, a an approval of, any noronon m any of the proulslons of the building code or of aAV City aedinonms. permfl't presuming too" outhonty to vwa& of cancel the pro"O" Lithe fumov coda or other on*nonett of the t by shag cot be void 0 P ARCHITECTURAL LEGEND 1 SECTION DETAIL, X=NUMBER, YZ=SHEET LOCATION OFFICE ROOM CALLOUT, NAME & NUMBER _> BATTERY BACKUP EMERGENCY EGRESS AND ® AREA LIGHTING (FROG EYES), COMBINED ®PACKAGE UNITS AS OR NOT AS INDICATED, ARROWS INDICATING EGRESS DIRECTION Eb�°y DOOR CALLOUT, REFER TO DOOR TAG LEGEND Xaa WALL/PARTITION CALLOUT REFER TO WALL SCHEDULE CLG FLR x•-xx• FLOOR OR CEILING HEIGHT, 1ST FLOOR GRADE 0'-0• R1 DRAWING REVISION LEVEL a EXISTING PARTITION TO REMAIN ------� EXISTING PARTITION TO BE REMOVED ® NEW PARTITION ® COMPASS DIRECTION NORTH — — -- PROPERTY LINE --------- CENTERLINE, CL OF ROW OVERHEAD/ABOVE PATH OF EGRESS DRAWING INDEX SHEET NO. SHEET TITLE DATE AO ARCH PLAN W/ MEP NOTES — COVER SHEET 10.13.20 Al ARCH PLAN W/ MEP NOTES 10.13.20 CODE ANALYSIS U GOVERNING CODES Project shall comply with the INTERNATIONAL BUILDING CODE 2018 International Codes W INTERNATIONAL PLUMBING CODE 2020 National Electrical Code Q 0 INTERNATIONAL MECHANICAL CODE J W °w 0 INTERNATIONAL ENERGY CONSERVATION CODE Cn INTERNATIONAL FUEL GAS CODE o 0 INTERNATIONA L FIRE CODE Lu Z 0 EXISTING BUILDING CODE NATIONAL ELECTRICAL CODE ANSI Al 17.1-2009 AMERICAN NATIONAL STANDARD PREM ISES ADDRESS: 3760 VANCE ST WHEAT RIDGE CO BUILDING SF: 1ST FLOOR: 2370 SF 0 2ND FLOOR: 2370 SF 3RD FLOOR: 2693 SF TOTAL: 7343 SF OCCUPANCY TYPE 302: BUILDING IS ENTIRELY F OFFICE "B" OCCUPA NI CONSTRUCTION TYPE 503: BUILDING QUALIFIES AS VB. 2 STORIES A BOV E G RA DE PLANE= 2 STORIES A BOV E LLJ Lz GRADE PLA NE A LLOWED MAX AREA PER STORY: 2693 SF < 9000 SF ALLOWABLE FIRE SEPARATION DISTANCES 602: BUILDING IS OVER 10' FROM PROPERTY LINE ON ALL SIDES AS SHOWN ON SITE PLAN. NO FIRE RESISTANCE RATING REQUIRED ON EXTERIOR WALLS FOR VB OPENING PROTECTION 705.7: EAST, WEST, AND SOUTH FACES OVER 30' FROM PROPERTY LINE, NO PROTECTION REQUIRED. NORTH FACE EXISTING NON-COMPLIANT. FIRE SPRINKLER 903.2.4: NOT FIRE SPRINKLERED. OCCUPANT LOAD: BUSINESS 1 PER 100 SF = 74 OCCUPANTS EGRESSES: MINIMUM TWO (2) EGRESSES REQUIRED; 100' COMMON PATH AND 200' MAXIMUM TRAVEL DISTANCE PLUM BING FIXTURE COUNT: 74 OCCUPANTS = 37 MEN, 37 WOMEN WCs: 1 per 25 for first 50; 2 req'd per sex. 3 provided per sex ACCESSIBILITY: NEW FIRST FLOOR ACCESSIBLE RESTROOM PROPOSED. ACCESSIBLE GRAB BARS AND LAVATORY BEING ADDED TO 3RD FLOOR RESTROOMS. ACCESSIBLE LEVERSEfS BEING ADDED ALL DOORS BEING TOUCHED. ACCESSIBILITY IMPROVEMENTS WELL EXCEED 20% OF VALUE OF PROJECT. PROJECT NARRATIVE: ON THE FIRST FLOOR, TWO SMALL EXISTING RESTROOMS ARE BEING COMBINED INTO ONE ACCESSIBLE RESTROOM WITH NEW ACCESSIBLE TOILET, LAVATORY, AND OTHER RESTROOM FIXTURES. AN ACCESSIBLE BI—LEVEL DRINKING FOUNTAIN IS PROPOSED IN THE HALLWAY AS WELL. ALSO PROPOSED ARE A MOP SINK AND A NEW REDUCED REDUCED PRESSURE BACKFLOW PREVENTER FOR FURTHER UPDATING TO CURRENT CODE STANDARDS. AI BI CI DI EI FI GI HI II JI KI LI MI NI 01 P ISSUE: BUILDING DEPT. ISSUE 10.13.20 CUSTOMER 3760 VANCE LLC DANIEL 14NG, P.E. 3760 Vance St#301 Wheat Ridge, CO 80033 IL z U Q QJ W J � N Q 0 Z W N J W °w 0 Q DC Cn _J o 0 NW Lu Z 0 W LLF U �I 0 W H M l-— = 0 Z U � Ii LLJ Lz Q ENGINEERING COMPANY U WZ_ W � � N Q Z W N 7W=COO W Q I— OZ NW Zo �> Z C)o WZ W •11 ENGINEERS STAMP POC L fC 1r+r eIN Pry�i C); 0.16.2`�'� i '; w 40380 z� / 7 rrrll���11",, `y{.10 5 CHECKED BY DIRK DRAWN BY DIRK RENO JAMES PROJECT NUMBER 19358 SHEET NO. AO 10 9 8 6 5 3 t SCOPE SYNOPSIS THIS SHEET: • COMBINE EXISTING RESTROOMS INTO ONE ACCESSIBLE RESTROOM; NEW FIXTURES AND FINISHES THROUGHOUT. • NEW ACCESSIBLE DRINKING FOUNTAIN TO REPLACE EXISTING WATER STATI O N • ADD MOPSINK & BACKFLOW PREVENTER IN SMALL JANITORS CLOSET. FI GI HI II JI KI LI MI N ® KEYED NOTES 1. NEW ACCESSIBLE WATER CLOSET, TANK, PROVIDE ACCESSIBLE GRAB BARS. 2. NEW ACCESSIBLE LAVATORY, WALL MOUNT. PROVIDE ACCESSIBLE FAUCET HARDWARE AND PIPE COVER. AMERICAN STANDARD LUCERNE WALL -HUNG VITREOUS CHINA ADA COMPLIANT OR EQUAL. 3. NEW MOPSINK & CLOSET AREA. PROVIDE 2468 DOOR WITH PASSAGE LATCH AND SHORT STUD WALL AS SHOWN. PROVIDE 6X6X04 EXHAUST GRILLE AT CEILING & ATTACHED TO BUILDING EXHAUST TRUNK VIA 04". PROVIDE NEW 1 " REDUCED PRESSURE BACKFLOW PREVENTER ABOVE MOPSINK. CONNECT TO J" EXISTING BUILDING SHUT OFF VALVE (#8) VIA 1 " PIPE, WHICH SHALL BE CONCEALED IN SLAB OR MARKED "NON -TAPPABLE". PROVIDE NEW A -BASE LIGHT FIXTURE AT CEILING W/ MOTION SENSOR; CONNECT TO EXISTING RESTROOM CIRCUIT. 4. REUSE EXISTING RESTROOM DOOR IF POSSIBLE OR PROVIDE NEW; PROVIDE NEW ADA LEVERSET W/ BATHROOM PRIVACY LATCH. 5. NEW STUD WALL, 3 J" 25 GA METAL OR 2X4 TIMBER STUDS, J" TYPE "X" GWB PURPLE BOARD / MOISTURE RESISTANT. 6. NEW BI -LEVEL DRINKING FOUNTAIN, ACCESSIBLE, WALL MOUNT. RE -WIRE EXISTING GFCI RECEPTACLE THIS AREA FROM OLD DEMOLISHED DRINKING STATION. 7. FINISH NOTES: 7.1. NEW FLOOR TILE AND TILE COVE REQUIRED BECAUSE OF DEMOLISHED WALL BETWEEN OLD RESTROOMS, INCLUDING AT DRINKING FOUNTAIN 7.2. NEW TILE BACKSPLASH REQUIRED 48" PAST PLUMBING FIXTURES PER CODE. 7.3. NEW SEMI -GLOSS PAINT REQUIRED ALL SURFACES INCLUDING CLG IN RESTROOM. EXISTING RESTROOM GWB CLG SHALL REMAIN, BE PATCHED AS REQUIRED, AND BE PAINTED. 7.4. PROVIDE VANITY MIRROR, AUTOMATIC PAPER TOWEL DISPENSER, TWO NEW CAN LIGHTS IN CEILING, NEW MOTION SENSOR WALL SENSOR +44" AT LEFT OF DOOR WHEN LEAVING RESTROOM; REUSE EXISTING RESTROOM ELECTRICAL CIRCUIT. T T T T T T T T a- a -- FIRST FLOOR EXISTING/DEMO PLAN FIRST FLOOR PROPOSED PLAN City of Wheat Rid SCALE: 1/4" — 1 -0 SCALE: 1/4" — 1 -0 e g Building Division AI BI CI DI EI FI GI HI I JI KI LI MI NI OI PI ISSUE: BUILDING DEPT. ISSUE 10.13.20 R1 CITY COMMENTS 01.16.20 CUSTOMER 3760 VANCE LLC DANIEL IgNG, P.E. 3760 Vance St ##301 Wheat Ridge, CO 80033 Z Q z J Q a o °- J � w 1.- 0 U) _j C) 0 Q ZU J Q z W LU j 0 W CL/ 7 W C) w W H MQ 0 OO 0 z = w V ZQ W 0 w rn 0 z Q ENGINEERING COMPANY 0 w U) w a� w z T_ LL] Q N W N J Q z W > o 7 W Q� � w � 0 z N Lu w ZQ w 0 w rn 0 z W00't CN 0 N W 0 I _ c� 0 0 ENGINEER DAN MNG, P.E. 4900 W 29th Ave Deng, CO 80212 303-800-5105 dldng@mnoj mes.00m ENGINEERS STAMP p 0 pr . r r = �, .•'ENO a•' �, i x0.16.2 w : z 40380 z: ' i CHECKED BY DRK DRAWN BY DRK RENO JAMES PROJECT NUMBER 19358.2 SHEET NO. A I From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: Commercial Interior Remodel/Tenant Finish Date: Wednesday, October 21, 2020 3:19:38 PM Commercial Interior Remodel/Tenant Finish Application for Commercial Remodel/Tenant Finish This application is for Commercial Remodels and Tenant Finishes. Do not being work until the permit has been issued to the General Contractor. Required to Submit Proof of Submission to Fire Department Proof of Submission to Fire Department Begin Application EmailRenort 5770 10152020.Ddf PROPERTY INFORMATION Property Address 3760 Vance St Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) 3760 VANCE LLC KI8BI:I8I8bid811 Property Owner Email dking@renojames.com Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Electronic Payment Form.odf APPLICANT INFORMATION Contact Name of Daniel Reno King Person Submitting Application What is your role in the Property Owner project? Contact Phone Number 303-800-5105 (enter WITH dashes, eg 303-123-4567) Contact Email Address dking@renojames.com for Plan Review Questions Retype Contact Email dking@renojames.com Address 01:K161CiI91 ffl0N]ayOLib]N:/ Is this for a new No tenant? Business Name of 3760 Vance LLC Tenant Detailed Scope of Combine two existing restrooms into single accessible restroom, Work - Provide a add backflow preventer, servicesink, accessible drinking fountain detailed description of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc Location of Work 1st floor restrooms Square Footage Area 75 of Work Being Performed Asbestos Report - if Asbestos Inspection Report - 3760 Vance Street Wheat Ridae applicable CO pdf Construction Plans 19358 3760 VANCE 101320.pdf scanned on 11'x17" or larger Project Value (contract 12000 $12,000 valuation is value or cost of ALL OK materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Daniel King Permit Email not displaying correctly? View it in your browser. City of Wheat�idge � MUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Mechanical Subcontractor This form must be completed & signed by the MECHANICAL SUBCONTRACTOR performing mechanical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: VA,v ` General Contractor: -?-) E- ` C o N 5 '' — FORA WILL NOT BE ACCEPTED NN ITH MISSING INFORMATION Company Name: 4 NF -u-2 Ef-a 1�,1E-C-i-kN�zcALContact Phone #: Wheat Ridge Contractor License #: ;-D (required field) ,:1.1v%z Si Printed Name of Authorized Agent i Signature of Authorized Agefit ��-zs-,Zazy Date II*,f"€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV;%–Íg´ZmV»e¶Ýo¸\nW;¥Öíw¼^oT¸€? P8$ „BaP¸d6ˆDbQ8¤V-ŒFcQ¸äv=HdR9$–M'”JeR¹d¶]/˜LfS9¤Öm7œNgS¹äö}? PhT:%G¤RiTºe6O¨TjU:¥V­W¬VkUºåv½_°XlV:Óñþþ³Z,ö›e®Ýj¸[n6û•Öéw¹Þn× îýx¿Þ°<‡Âb0؜f/ŠÈcr8ü–W)—ÉærÙ¬Åáôý~gߏ·ö‚Îý¿õp¬3>ÂS;C%@«•= ñÙ2žÓ4€ÐÖü Qu©õ[Ö™ûRië_Õ§±ïaׇ¬BzÏVE!ÐIïg9‡»˜|-1òyQ‡yêyÇ¡äxÇ¡çFXÐÝsÜ×LÁuÃMí%LÖçÄEFŸeëiCVœj—åü´+EñcZôeÁoL¶Qõ´'¡ôzÛG ºwÙ§¹öÑbçí{qՌágÝ°yž'¹äzsYø{䧑Öx‡V<xž§‰ñ~ŸGñô{ggèx§‰Úuç]ž{ž‡Áèw[‡YàuÇ–˜{žgž©š'qݧbG™éš[g¡êy:ÉØvGIÔsœÇ9Èu‡Nªx0ý3DQÇ©í5_§m¸s‡AÔx˜qê{ŸÇÎ(xœ§aÎrg6#i™òzçqÒpœç̞‡y՘s'IÌvðY†lyž¹^{ux uœgIÈo†ÿpoœgW!˜\>w‘ø6ÆŔðؙÑÑ6#¿Çaå¡æNŸÒóøïMÔ{Ge¹–Û§‡ s‡»è~™Ó¢ûG9Útû^^ÓÑb>—QÍq¼#ñÿœÀ<]¨ä t i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: f Job Address: h U71%jC 6 r '1 Permit Number: o Z -X>(D ; r :-, ❑ No one available for inspection: Time _U.' L: AM Re -inspection required: Ye No A When corrections have been made, cafl for re -inaction at_303- Date:- 03- Date:_ _ _ Inspector: 11 f7 z DO NOT REMOVE THIS NOTICE RENO JAMES E N G I N E E R I N G October 15, 2020 Randy Slusser, CBO Chief Building Official Building Division Office Phone: 303-235-2803 RE: 3760 Vance St Review Number 202000065 Dear Randy, 3760 VANCE ST #301 WHEAT RIDGE, COLORADO 80033 PHONE: 303.800.51 05 DKING@RENOJAMES.COM I am writing this letter to address the removal of the 1st floor restroom remodel component from this permit. Due to budget and the pandemic, we proceeded forward with just the 3rd floor office remodel project first, so my company could move into one of our new suites. Next, we are upgrading the 1st floor restrooms. I have applied for this as a second, separate permit. I just got notice from West Metro Fire Protection that our application was accepted; copy of email attached. I will shortly apply for the second Wheat Ridge permit. My apologies for any confusion or inconvenience, but this is the only way I know of phasing projects like this. Thank you very much. Regards, Dan King, PE Reno James Engineering City of 'rW heat Ridge COMMUNRY DEVELOI'MENT APPROVED Reviewed for Code Complianee Randy Slusser 11/18/2020 Plans Examiner Date %FMW tv of oesmit: The issuance of o permit or Wp--1 of plans sWcift -V*r and computations shop not be a permit f tr or an opprovot of, any vaolobon to any of the provislom of ft burtdtag code or of aW qty or0nances. Permits presuftng to give out" to v(olom or cancel the pro"" of the 600V coda or other wdrnoom of the City shoes not be vand . F per' � .�ENOe� ,tis rri 0.16.2 w 40380 z - �•Ci VNO RENO JAMES ENGINEERING • 3760 Vance Street Suite 301 • Wheat Ridge, Colorado 80033 www.renojames.com 9 303.800.5105 9 info@renojames.com 4' CITY OF WHEAT RIDGE V, Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: IJ AIVIV-1 No one available for inspection: Time PM Re -inspection required: Yes ;No When corrections have been made, schedule for re -inspection online at: http✓/www. cL wheatridge, co. uarinspection Date: 1,21 Inspector: DO NOT REMOVE THIS NOTICE a i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: cr Job Address: Permit Number: AF e - ❑ No one available for inspection: Time 0� AM/PM Re -Inspection required: Yes - No *When corrections have been made, sch le for re -inspection online at: hUpYAvvww.ci.wheatridge.co. usrnspecti n Date T pe tor: . i CITY OF WHEAT RIDGE Building, Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: 02' Job Address: Permit Number: (A ( CA o6 U br c CA {C ovs c h Av( no V re 2✓t ) e Ile / eA— roV A(jkl tnt,'& SCv/C ❑ No one available for inspection: Time wo AM/PM Re -Inspection required: Yes '-No When corrections have been made, schedule for re -inspection online at: http✓/www.ci. wheatridge.co. uslinspection Date: � Inspector: DO NOT REMOVE THIS NOTICE N rt w ynbyz a m m"rt :; A $ xt H n o F,� n m oY00 r -11 o oN rr •s o b o co z ��rA �o n ° ° b `''� to PC ^ n Cr1 " o D' 0� r�zD fr t y CD H �, (D(D a `D On m T c o. z rt, 0 a �? n >12. rl y m x a" a m mv ma >~ ��° �o d�n fni- p Gd K E Ct k EA CL G � m O W p FY -O C] fD o w o� w O x rn O rIJ O ! cD A H N w fD p p a 9 C b W � O H O � n� v°, p p0 car0 rh H C b m a. � 1 rt PC CrQ ft m o m O o n H. O " E. a. !�C3 a z CD ° c �• -1y y LQ q W. ^ rr o O o rt c �, y 10 f7 5 c o 10 Q ° ems Y• pr a I G o O City of ,/~ Wheat e g BUSINESS LICENSE INSPECTION PERMIT NO. 202001874 INSPECTION DAY/TIME Tues. Sept 29 @ 11 am INSPECTION DAY/TIME INSPECTION DAY/TIME 11;0-3 cc lig BUSINESS NAME: Josh Herman Arts LLC ADDRESS: 3760 Vance Street Suite 101 CONTACT NAM E: Joshua l C 0 SQ FT --L.,l OCCUPANCY TYPE (P OCCUPANCY LOAD CONSTRUCTION TYPE ❑ SPRINKLERED .[�rNOWSPRINKLERED Date i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: �&�� Job Address: Permit Number: 45=�Z�— ❑ No one available for inspection: Time I )PM Re -Inspection required: Yes *When corrections have been made,c edule for re -inspection online at: hUpYA4(ww. ci. wheatridge. co. ushnsp#c ion _ Da(4�� ' ` )-'Z E InS a torte � I CITY OF WHEAT RIDGE r� Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Y-V,V9 )p c Job Address: Permit Number: u ❑ No one available for inspection: Time t ' ' AM/PM r, Re -Inspection required: Yes Nod "When corrections have been made, schedule for re -inspection online at: httpA/www.ci. wheatridge.co. uslinspection Date: ``l `t °i� Inspector: i DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: z CJ-S',el-7,- Ste' Job Address: F z a 4�2 �Q/�, e -P _ - f '-elpl Permit Number: 7_„#1 ZfC7 p 1 %,T 7 ❑ No one available -for inspection: Time Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge.co. us-Vinspection Date: ?>/'a2i_eoInspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: 71�- -� �^' ✓ i `� Permit Number: ❑ No one available for inspection: Time '� - AM/PM Re -Inspection required: Yes No 3. When corrections have been made, schedule for re -inspection online at. http✓/www. ci. wheatridge. co, usdnspection Date: Inspector: DO NOT REMOVE THIS NOTICE IV s 4' CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: U Permit Number:��,� ❑ No one available for inspection: Time i I*,� AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. uslinspection Date:' -"7,A <j Inspector: DO NOT REMOVE THIS NOTICE Lep aJr)n Cc S�- 5366 Godding Hollow Pkwy EARTH ENERGY ENVIRONMENT (E3) Longmont, co 80504 Local: 303.902-5551 Industrial Hygiene and Environmental Engineering September 9, 2020 Mr. Roger Beaver Beaver Construction Consulting, Inc. 5350 S. Marshall Street, Littleton, CO Subject: Ambient Air Monitoring 3rd Floor — Remodel Area 3760 Vance Street Wheat Ridge, CO Dear Roger: Following are the visual observations and ambient air monitoring results collected from the 3rd floor remodel area at 3760 Vance Street, Wheat Ridge, CO. The observations and air monitoring were conducted on September 9, 2020. An Industrial Hygienist for Earth Energy Environment (E3) performed the observations and ambient air sampling. The air samples were collected following removal of non asbestos containing materials. The purpose of the observations and air sampling were to confirm that asbestos containing materials were not disturbed and asbestos amplification was not present in the work area. Phase Contrast Microscopy (PCM) samples were collected in accordance with the National Institute for Occupational Safety and Health (NIOSH) method 7400 using cassettes (standard 3 piece, 25 mm dia., 0.8 um NICE filter) purchased from Zefon International, Inc. Asbestos concentrations in the containment were calculated as airborne fibers per cubic centimeter of air (F/cc). Table 1 provides a summary of the sample numbers, sample volumes, and calculated concentrations. The National Emission Standards for Hazardous Air Pollutants (NESHAP) clearance standard is 0.01 F/cc. TABLE 1: AMBIENT AIR MONITORING RESULTS. Date Unit/ Area f Sample # Sample Description Sample Volume Fibers/cc I � Ambient Air September 9, Monitoring AM -090920-1 Inside 1125 0.001 2020 AM -090920-2 Work Area 1115 0.001 (3rd Floor) *The PCM Colorado Department of Public Health and Environment (CDPHE) clearance standard is 0.01 F/cc. �-- Ambient Air Monitoring Page 2 of 2 Based on the visual observations and ambient air samples collected from the 3rd floor work areas, asbestos containing materials were not disturbed and asbestos amplification was not detected. Thank you for allowing E3 the opportunity to provide environmental services to you. If you have questions or require additional information, do not hesitate to contact me directly at (303) 478-0922. Respectfully Submitted, EARTH ENERGY ENVIRONMENT (E3) Arthur Willden, P.E. Engineer / Industrial Hygienist Certified Air Monitoring Specialist No. 20138 e i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: _4 \ n r _ Permit Number: U ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes iNo When corrections have been made, schedule for re -inspection online at: hUp✓/www.ci, wheatridge. co. uarinspec tion Date: / e rL 1 1 �'i'd''Inspector: ®O NOT REMOVE THIS NOTICE I* ® l i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: (2n r-, c-- �) Job Address: 0_ 0 A 0. C � �i- Permit Number: � �� r-` U ❑ No one available for inspection: Time !(LA) AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. usOnspection Date:—'7 Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Y �� No, t When corrections have been mad , hedule for re -ins ction on e,,at. http://www.ci.wheatridge.co.0 ins ect� Dae . __`_ sector ^�---- �-- } ! A CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: S\ - Permit Number: 00c� 0 UcI� C jr 4- iu I.J No one available for inspection: Time Ra AM/PM Re -Inspection required: Yks'; No 71 When corrections have been made, schedule for re -inspection online at: http✓/www.ci, wheatridge. co. ushnspection Date:- Inspector: DO NOT REMOVE THIS NOTICE - I C I LN/ Of h ..!�Te C(,)M,MUN1T-),' DEVELOP -M, ENT Plumbing Subcontractor This form must be completed & signed by the PLUMBING SUBCONTRACTOR performing plumbing work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: General Contractor: Company Name: �P) * Contact Phone #:,--302- Wheat Ridge Contractor License #: -/ ajS I /) /I (required field) State License #: M 65 /,2 /-Z9 Master License Z262042 3 Printed :lame of Authorized Agent Signature otAuthorized gent Date City of Wheat Ridge Comm. Tenant Finish PERMIT - 202000065 PERMIT NO: 202000065 ISSUED: 03/12/2020 JOB ADDRESS: 3760 Vance St EXPIRES: 03/12/2021 JOB DESCRIPTION: Commercial tenant finish removing one wall and adding small bar sink. Updating 3rd floor bathrooms to ADA requirements. Square footage: 1340 *** CONTACTS *** OWNER (303)800-5105 3760 VANCE LLC SUB (303)650-6050 KATHLEEN MURPHY 130100 JULES PLUMBING CO. OF DENVER GC (720)938-1608 ROGER BEAVER 202011 BEAVER CONSTRUCTION CONSULTING SUB (303)475-7950 WILLIAM J BAUER 202063 HINDSIGHT ELECTRIC LLC SUB (303)777-1234 JAMES & DIRK PASTERKAMP 017887 PASTERKAMP HEATING & AIR COND. *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: 520 / Office; 0 *** FEE SUMMARY *** Total Valuation Plan Review Fee Use Tax Permit Fee ** TOTAL ** *** COMMENTS *** USE: UA / Unassigned BLOCK/LOT#: 0 / ESTIMATED PROJECT VALUATION FEES 0.00 636.42 1,695.62 979.10 3,311.14 80,744.00 *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. City of Wheat Ridge :�9Comm. Tenant Finish PERMIT - 202000065 PERMIT NO: 202000065 ISSUED: 03/12/2020 JOB ADDRESS: 3760 Vance St EXPIRES: 03/12/2021 JOB DESCRIPTION: Commercial tenant finish removing one wall and adding small bar sink. Updating 3rd floor bathrooms to ADA requirements. Square footage: 1340 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this e further atte hat I am legally authorized to include all entities named ithin this document as parties to the work to be perfp med nd that all o to be performed is disclosed in this document n(d/or its accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermrt fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services 6. Phuance orgra i g of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any ble ode or ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Or* Wh6atd i r F:' o" �� g MIMUN r -y DE4ELCH? ENT SUBCONTRACTOR AUTHORIZATION FORM Electrical Subcontractor This form must be completed & signed by the ELECTRICAL SUBCONTRACTOR performing electrical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 374o. (�, c -- General Contractor: ���` ��LC '-�"'�L�'t2 5%> 1--r Company Name: Hindsight Electric, LLC Contact Phone#: 303-475-7950 `Vheat Ridge Contractor License #: State License #: E C, 010 0 8 4 9 Master License #: M E. 0 6 0 0 0 7 8 W illia m J Bauer Printed Name of Authorized Agent D:gr.auy s:�ned by Jon Baser Jon Bauer Dv.,J Jen Bader �B,,, ah, Be S mail=;on Qrh,nds�:gb:e�e;�ric.,n m. �=US Dar 2020.03, 0513:45' 2B 07'00' Signature of Authorized Agent 202063 (required field) f. 03/05/2020 Date City of Wh6atps idge COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Plumbing Subcontractor This form must be completed & signed by the PLUMBING SUBCONTRACTOR performing plumbing work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 3,746 V*,J46 S General Contractor: Company Name:..... Gl�'%l�� _Contact Phone #:_ lvl�� ' C�6✓�o 40 Wheat Ridge Contractor License #: a0��'f7(uired field) State License #: d c O 2 3 Master License #: DG 7q p,T2, 1002--D _ Date City of ��Wh6atp,idgie COMMUNITY DEVELOPMENT Building & Inspection Services 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(cki.wheatridge.co.us I FOR OFFICE USE ONLY I Date: 6/./ 2_0v -Z Plan/Permit # J-0,9, C) Plan Review Fee: �_& Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3760 VANCE ST, WHEAT RIDGE, CO 80033 Property Owner (please print): 3760 VANCE LLC (Daniel King owner) Phone: 303.800.5105 (office) Property Owner Email: dking@renojames.com, jennifer@renojames.com (office manager) 720.936.5131 (cell) Tenant Name (Commercial Projects Only) Reno James LLC dba Reno James Engineering Property Owner Mailing Address: (if different than property address) Address: City, State, Zip: Daniel King, PE (same as owner) Architect/Engineer: Same as above Architect/Engineer E-mail: Contractor Name: Roger Beaver City of Wheat Ridge License #: Phone: Same as above getting from contractor Phone: 720.938.1608 Contractor E-mail Address: rogerrbjb@aol.com For Plan Review Questions & Comments (please print): CONTACT NAME (please print): Daniel King, PE Phone: CONTACT EMAIL(p/ease print): dking@renojames.com 303.800.5105 Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W. R. City License # W.R. City License # W. R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields, if applicable— ❑x COMMERCIAL ❑ RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. 3rd floor office being remodeled to make a nice new home for my engineering business. One wall being moved about 8 feet, and a small bar sink adjacent to the restrooms being added for a coffee maker. Existing 2x4 ceiling grid needs work, diffusers and lights to replaced. Replacing lights with new LED troffers. Reducing power by well under half. No new lights or diffusers. Was an office, will still be an office, no change in occupancy. About 1200 sf. The relocated wall will require about 200 sf of new flooring to be installed. Maybe two new receptacles may need to be installed. 3rd floor restrooms also to be updated. New accessible fixtures with grab bars, new wall mount lavatory. New paint, tile back splashes, etc. About 75 SF. Lastly, on 1 st floor, two small restrooms being combined for Accessibility. New mopsink and backflow preventer proposed above it in closet. New Acessible drinking fountain. About 65 SF. Sq. FULF 1340 SF BTUs N/A Gallons N/A Amps 800A Squares For Solar: KW # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: "B" Construction Type:VB Occupancy Load: 75 Square Footage: 7343 IProject Value: (Contract value or the cost of all materials and labor included in the entire project) I C 80,744 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): � ) I IG -L"" DATE: 01.07.2020 Printed Name: Daniel King ZONING COMMMENTS: Reviewer: BUILDING DE=MENT MM NTS: Reviewer: t�Z�j�Zv PUBLIC WORKS COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: 13 CONSTRUCTION TYPE: 90 Building Division Valuation:�bl-/qq Randy Slusser To: dking@renojames.com Subject: Plan review for remodel at 3760 Vance Street - Review number 202000065 Hi Daniel, The Building Division has reviewed your plans for conformance and have the following comments/clarifications needed. 1. Sheet Al: First floor: New accessible restroom a. Water closet is encroaching in minimum 60 inch diameter turning space. The knee and toe clearance for required for the lavatory is allowed to encroach but not the water closet. A117.1- 2009 section 304.3.1 b. Show on plans that there is a clear floor space of 30"x48" beyond swing of door. A117.1-2009 section 603.2.2, exception 2. 2. Sheet Al: Revise finish note 7.2 to read 48 inches instead of 24 inches. 2012IBC Section 1210.2.2 3. Sheet A2: Note 3 — Provide notes that new sink and counter in Suite 301 will meet accessibility requirements of A117.1 —2009 section 804 a. Clarify that it is understood the restrooms on the second floor are only receiving minor face change updates, and will not meet all current accessibility requirements for turning radius and clearances. 4. Clarify location of supply and return air for office spaces. Will any additional duct work be added? If so, provide mechanical drawings, Randy Slusser, CBO Chief Building Official Building Division Office Phone: 303-235-2803 Y City of _:�W heat jdge COMMUNITY DEVELOPMENT CONFIDENTIALITY NOTICE: This e-mail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you. n�( COMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Construction Site: 3760 Vance St #301 Wheat Ridge, CO 80033 Allowed Interior Lighting Power 2012 IECC 3760 Vance St #301 Alteration Owner/Agent: Designer/Contractor: Dan King RJ E 3760 Vance St #301 Wheat Ridge, CO 80033 A B C D Area Category Floor Area Allowed Allowed Wafts (ft2) Wafts / ft2 (B X C) 1 -Office (Common Space Types:Office - Open plan) 1200 1.00 1200 Total Allowed Watts = 1200 Proposed Interior Lighting Power A Fixture ID : Description / Lamp I Wattage Per Lamp I Ballast Office ( Common Space Types:Office - Open plan 1200 sq ft ) 2x4' LED tropher: Other: B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 1 20 32 640 Total Proposed Watts = 640 Interiore a PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.1.1.0 and to comply with an applicable mandatory requirements listed in the Inspec�ChecklistPA N K. 0 C ,'� Name - Title ! Si nature Date r % a hl?eat ININQ 3110 NA. tt� 61''x" Project Title: 3760 Vance St #301 �Z3J�� Report date: 01/08/20 Data filename: Untitled.cck ' L Page 1 of 6 aIli bsomb 9 Z�o'Lo COMcheck Software Version 4.1.1.0 1s( Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # & Req.ID I i Plan Review Complies? Comments/Assumptions C103.2 Plans, specifications, and/or ❑Complies [PR4]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the interior lighting ❑Not Applicable and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: 3760 Vance St #301 Report date: 01/08/20 Data filename: Untitled.cck Page 2 of 6 Section # Rough -In Electrical Inspection Complies? Comments/Assumptions & Req.ID _ C405.2.2. Automatic controls to shut off all ❑Complies 1 building lighting installed in all ❑Does Not [EL22]2 buildings. ❑Not Observable ❑Not Applicable _ C405.2.1. Independent lighting controls installed ❑Complies 1 per approved lighting plans and all ❑Does Not [EL23]2 manual controls readily accessible and ❑Not Observable visible to occupants. ❑Not Applicable C405.2.1. Lighting controls installed to uniformly ❑Complies 2 reduce the lighting load by at least ❑Does Not [EL15]1 50%. ❑Not Observable ❑Not Applicable C405.2.2. Daylight zones provided with ❑Complies 3 individual controls that control the ❑Does Not [EL16]2 lights independent of general area ❑Not Observable lighting. ❑Not Applicable C405.2.3 Sleeping units have at least one ❑Complies [EL17]3 master switch at the main entry door ❑Does Not that controls wired luminaires and ❑Not Observable switched receptacles. ❑Not Applicable C405.2.2. Occupancy sensors installed in ❑Complies 2 required spaces. ❑Does Not [EL18]1 ❑Not Observable ❑Not Applicable C405.2.2. Primary sidelighted areas are ❑Complies 3 equipped with required lighting ❑Does Not [EL20]1 controls. ❑Not Observable ❑Not Applicable _ C405.2.2. Enclosed spaces with daylight area ❑Complies 3 under skylights and rooftop monitors ❑Does Not [EL21]1 are equipped with required lighting ❑Not Observable controls. ❑Not Applicable +C405.2.3 Separate lighting control devices for ❑Complies [EL4]1 specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ❑Not Applicable C405.3 Fluorescent luminaires with odd ❑Complies [EL19]3 numbered lamp configurations that ❑Does Not are within 10 feet center to center (if ❑Not Observable recess mounted) or are within 1 foot ❑Not Applicable edge to edge (if pendant or surface mounted) shall be tandem wired. C405.4 Exit signs do not exceed 5 watts per ❑Complies [EL6]1 face. ❑Does Not ❑Not Observable ❑Not Applicable lC405.2.3 Additional interior lighting power ❑Complies [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is ❑Not Observable automatically controlled and ❑Not Applicable j separated from general lighting. Additional Comments/Assumptions: 1High Impact (Tier 1) j 2 ,Medium Impact (Tier 2) T3 I Low Impact (Tier 3) i Project Title: 3760 Vance St #301 Report date: 01/08/20 Data filename: Untitled.cck Page 3 of 6 Section # Final Inspection Complies? Comments/Assumptions C408.2.5. Furnished as -built drawings for ❑Complies 1 electric power systems within 30 days ❑Does Not [F116]3 of system acceptance. ❑Not Observable ❑Not Applicable C303.3, Furnished O&M instructions for ❑Complies C408.2.5. systems and equipment to the []Does Not 2 building owner or designated ❑Not Observable [F117]3 representative. ❑Not Applicable C405.5.2 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [F118]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting [:]Not Observable plans, demonstrating proposed watts ❑Not Applicable are less than or equal to allowed watts. C408.3 Lighting systems have been tested to ❑Complies [F133]1 ensure proper calibration, adjustment, ❑Does Not programming, and operation. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier1) 2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: 3760 Vance St #301 Report date: 01/08/20 Data filename: Untitled.cck Page 5 of 6 Project Title: 3760 Vance St #301 Report date: 01/08/20 Data filename: Untitled.cck Page 6 of 6 1/9/2020 renojames.com Mail - Permit application accepted - West Metro Fire Protection District Gmufl Dan King <dking@renojames.com> Permit application accepted - West Metro Fire Protection District 1 message NoReply@mobile-eyes.com <NoReply@mobile-eyes.com> To: dking@renojames.com Thu, Jan 9, 2020 at 8:36 AM Your permit request for Vacant at 3760 Vance Street Wheat Ridge, CO 80033 has been accepted. The Job Number is: 200109006 Description: 3rd floor office being remodeled to make a nice new home for my engineering business. One wall being moved about 8 feet, and a small bar sink adjacent to the restrooms being added for a coffee maker. Existing 2x4 ceiling grid needs work, diffusers and lights to replaced. Replacing lights with new LED troffers. Reducing power by well under half. No new lights or diffusers. Was an office, will still be an office, no change in occupancy. About 1200 sf. The relocated wall will require about 200 sf of new flooring to be installed. Maybe two new receptacles may need to be installed. 3rd floor restrooms also to be updated. New accessible fixtures with grab bars, new wall mount lavatory. New paint, tile back splashes, etc. About 75 SF. Lastly, on 1st floor, two small restrooms being combined for Accessibility. New mopsink and backflow preventer proposed above it in closet. New Acessible drinking fountain. About 65 SF. Thank you for submitting to West Metro Fire. Our typical review turnaround is approximately 6 weeks. You can now view where your plan review is at in the queue! Please click the link below: hftp://www.westmetrofire.org/l 01 3/Plan-Review-Status BE ADVISED WE NO LONGER ALLOW WORK TO BE DONE PRIOR TO APERMIT BEING ISSUED AND PLACED ON SITE. If additional information is required, you'll receive a notice from the reviewer assigned, or a no -reply notice from Mobile Eyes. Please be sure to check your junk folder if you feel you are not receiving the Mobile Eyes notices and select "Not Junk". If you check the status of your review through your Mobile Eyes Contractor Portal you may see a note that says "zoning checks not passed". This is not checked until a permit has been issued and fees have been paid. This is an internal way for us to keep inspections from being requested until the above has been completed. NOTE: Re -submissions shall only include the pages that are affected and additional pages that may be required for the needed corrections. Re- submission of full sets, unless specifically requested, shall result in the rejection of plans. https:llmail. google.com/mail/u/0?ik=10dca6db39&view=pt&search=all&permthid=thread-f%3Al 655265466200659579%7Cmsg-f%3Al 655265466200... 1/1 o/ �,'OZt)a�1�S EARTH ENERGY ENVIRONMENT CORP 5366 Lonngmont,ollow CO80050 Local: 303.478-0922 Industrial Hygiene and Environmental Consulting December 8, 2019 Mr. Dan King, P.E. Reno James Engineering 4900 W 29"' Ave, Denver, CO 303.800.5105 Subject: Asbestos Inspection Report — 3760 Vance Street, Wheat Ridge, CO Dear Mr. King: Earth Energy Environment (E3) is pleased to submit results for the bulk sampling at the commercial property ("subject property") located at 3760 Vance Street, Wheat Ridge, CO. i The sampling was conducted on December 5, 2019. The sampling was conducted for the purpose of determining if asbestos containing materials are present in the building. For the survey, samples of surfacing material were collected using the EPA random sampling protocol outlined in the EPA publication, "Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials" ("Pink Book", EPA 560/5-85-030a, October, 1985). LIMITATIONS %ew , IWh This investigation was conducted and the report prepared solely for property o ers. No Ridge warranties for other uses are applied and intended. Evaluations of conditions at this site we au 1d�lbDi 801 Survey Report 21Pa from a limited number of observation points and conditions cannot be warranted at non - observation points or non -accessible areas. The sampling included the suspect asbestos containing materials based on visual observations and discussion with the property representative. Interpretations and conclusions made in this report that pertain to the asbestos are based solely on results of independent laboratory analyses of the samples taken at the property at the date and time indicated. E3 has no control over such testing and analyses and, therefore, disclaims any responsibility for errors or omissions arising there from. INSPECTION RESULTS E3 sampled forty-six (46) homogeneous areas, as summarized below. E3 collected at least the minimum number of samples for the homogeneous area necessary to meet all regulatory requirements. Homogeneous Areas (HA): Homogeneous areas were selected from the building materials observed during the site inspection. The homogeneous areas sampled during the inspection are listed below. HA Description Friability Material Potential forCondition Disturbance 1 Exterior Brick Mortar Friable Good High 2 Block Coating (stairwells) Friable Good High 3 Unit 200B Walls Friable Good High 4 3rd Floor Hallway Walls Friable Good High 5 Unit 200B Bath and Hallway Friable Good High 6 3rd Floor Ceiling Tiles (newer) Friable Good High 7 Hall Ceiling Tiles (older) Friable Good High 8 Front Entry 1st Floor Walls Friable Good High 9 Unit 301 Walls Friable Good High 10 3rd Floor Stairwell Ceiling Friable Good High 1 1 Cove Base Glue Non -Friable Good High 12 3rd Floor (above tiles) Joint Compound Friable Good High 13 3rd Floor Stairwell Wall Paper Wall Friable Good High Survey Report 31Page 14 Unit 100 Walls Friable Good High 15 Roof Mastic Non -Friable Good High 16 Unit 200A Brick Coating Friable Good High 17 1 st Floor Storage Room Walls Friable Good High 18 Unit 100 and Unit 101 Walls Friable Good High The laboratory separated and analyzed individual layers within each sample, if present (see Attachment A). Table 1 provides a summary of the homogeneous areas, associated samples numbers, area description, classification, material type, and laboratory description of the sample makeup. Table 1. Sampling Results. Sample Area Classification Asbestos HA / AHERA Description No. Description Content Category Exterior Brick Misc. No Asbestos 1 1 2 A Off white mortar Mortar Materials Detected A Off white/multi-colored Block Coating Surfacing granular material No Asbestos 2 3-5 (stairwells) Materials B White block filler w/ Detected light gray paint A Off white compound w/ light beige paint Unit 200B Surfacing No Asbestos 3 6-8 Off B Owhite compound w/ Walls Materials Detected cream paint C White/tan drywall A Off white resinous 3rd Floor material No Asbestos 4 9-10 Misc. Materials Hallway Walls B Yellow wall covering w/ Detected off white paint A White paint Unit 200B B White joint compound 2% to 3% 11-11), ' Misc. Materials 5 Bath and C White compound Chrysotile 39 «5„ Hallway D Off white tape Asbestos E White/tan drywall 3rd Floor 14-15, No Asbestos 6 Ceiling Tiles Misc. Materials A White/gray ceiling tile 41 Detected (newer) Hall Ceiling Misc. Materials A White/off white ceiling 4% Amosite 7 16 Tiles (older) 4'5" tile Asbestos Survey Report 41Page Front Entry A Off white compound Misc. Materials 2% Chrysotile 8 17-19 1st Floor B Brown/offwhite paint Walls « „ 5 C Off white/tan drywall Asbestos Surfacing A White joint compound 9 20-24 Unit 301 Materials Off B Owhite tape 2% Chrysotile Walls Asbestos "5" C Off white compound 3rd Floor A Off white paint Mise. Materials 2% Chrysotile 10 25-26 Stairwell B White compound «5„ Asbestos Ceiling C Off white/tan drywall Surfacing A Brown adhesive 27-28, Cove Base 2% Chrysotile 11 40 Glue Materials B Off white/tan drywall w/ Asbestos 445" off white paint A Off white tape 3rd Floor Surfacing B Off white compound (above tiles) 2% Chrysotile 12 29-30 Materials Off C Owhite joint Joint Asbestos "5" compound p Compound D Off white/tan drywall A Off white/multi-colored 3rd Floor Surfacing paint w/ a trace of white No Asbestos 13 31-32 Stairwell Wall Materials compound Detected Paper Wall B White/tan drywall A White compound w/ Surfacing gray/multi-colored paint Unit 100 3% Chrysotile 14 33-34 Materials B Off white tape Walls "5" C White joint compound Asbestos D Off white/tan drywall Surfacing A Black tar w/ gray fibrous 4% Chrysotile 15 35-37 Roof Mastic Materials material Asbestos «5„ A Gray granular Unit 200A Surfacing No Asbestos 16 38 ementitious material w/ c Brick Coating Materials Detected off white paint A Off white tape B Gray/multi-colored paint 1 st Floor Surfacing 42, 45- C Off white joint 2% Chrysotile 17 Storage Room Materials 46 compound Asbestos Walls 445„ D Off white texture E Off white/tan drywall A Off white/multi-colored paint Unit 100 and Surfacing B White texture 2% Chrysotile 18 43-44 Unit 101 Materials C Off white tape Asbestos Walls «59 D White joint compound E White/tan drywall AHERA Category "5" = ACBM with potential for significant damage. Survey Report 51`', _ SUMMARY AND CONCLUSIONS According to the laboratory analysis of the materials sampled, asbestos was detected in the following material types and areas: • 1st, 2nd, and 3rd Floor Textured Drywall Walls and Ceilings • Cove Base Glues • Roof Mastics • Ceiling Tiles (older style) The Colorado Department of Public Health and the Environment requires any asbestos containing material greater than 1% that is friable or will be made friable during demolition activities be removed prior to demolition by a certified abatement contractor. Any other potential asbestos containing materials identified in the future or during demolition that were not sampled in this, or any other previous survey, should be tested for asbestos content or assumed to contain asbestos before being disturbed. 1f you have questions or require additional information, please contact me at (303) 478-0922. Respectfully Submitted, EARTH ENERGY ENVIRONMENT (E3) Arthur Willden, P.E. Engineer / Industrial Hygienist Survey Report 61 !• Attachment A Laboratory Results Reservoirs Environmental, Inc Effective April 02, 2018 Reservoirs Environmental QA Manual Q:\QAQC\Lab\Reservoim Environmental QA Manual.doc /"1/ ir5r ReSe v Envirvn/77e a nt 1, Inc. REI T December 06, 2019 Eli Willden Earth Energy and Environment Corp. P.O. Box 348 Frederick CO 80530 Dear Eli, Subcontractor Number: Laboratory Report: Project #/P.O. #: Project Description: RES 451109-1 None Given 3760 Vance Street Wheat Ridge Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 451109-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, by Josh Baker Jeanne Spencer President P:303-964-1986 5801 Logan St, Suite 100, Denver, CO 80216 1-866-RESI-ENV F:303-477-4275 wH,v.reilab.com J U Z_ J LQ r Z W Z O Z W Nn w 0 W �:w�y w O a O 'O SU U E u) N -0 Z m w U U O Z O O Q nO .O E o a` m o � c c W Co N w U U U 02 c D 1 Y C 0 0 O m 0 U � o 0 O O. 0 N E a R 0 C O w, C 0 c C j cn CO W m d O r O R w N = N r T fn � M lD r C ' 'o O S LOW R > EE O v t m O y i y N (6 x W Z M a W a o O a O 'O SU U E u) N -0 Z m w U U O Z O O Q nO .O E o a` m o � c c W Co N w U U U 02 c D 1 0(D 0 0 0 0 0 0 0 0 o 0 0 0 a 0 0 0 0 0 0 0 0 0 CO O CO Z C l0 m 0 0 a> O IL O Q O N (6 C6 E E c O Q O U R O) O _O U N N E E 0.2 0 0 0 0 0 0 0 0 0 0 m O LO Z in O N" rn N �- v v r QC rnv � o0 W nM � a ii Nc -0.-O Q LL Q. E O U N�.. Z Z Z Z Z Z Z Z Z Z Z Z 0 = W co O N d Q C R O O O CO � co 0) N O E m Q a _a O U (6 O N Q' _ _E O E C C Q C R C E U Q Q m Q R Fa Q .O Q_ N N T T T -Q E U Q O)01 O +T it- 15 70 U N O) N m 0CUO O -O C -O C -0 C 3 — O 2 — — .� N O Q O Q N O 0 Z+ p .� LF- E E E EEE U U a U O O -O O L D o o>> J> 0 o> o J Q W Q Q Q m Q c0 Q Q m U Q m N Cl) N � U cu Fo N Y U Y U 1 U t6 > O m _O m O m (a d � O O�� '� m m (n fn fn O N O N o E E C� U Y U Y U �C U .- tf U m Z m m m m m D N 0 U 0 o rt' v m N � m a R _ m d � U U C l0 m 0 0 a> O O N (6 C6 E c O Q U R O) O _O N N E E O U N N T (6 rn N �- v v r QC rnv � o0 W nM � a ii - Q _Z � « � Z W 2 Z O > 2 LU Cl) _w O uiƒ U) W w 0 £(a /�\ E y % G° ± =z 2 E- =3 aaf » » _ 0 �\a LU \ \ k ] k ±0000 S© CL 2 g 0 2 G G§\/ ° � E \§ 2 E § 2 0 ' I �f SCD o ; e c I C4 7> §w§ a CD Lo Luo>EtoE " / 2 k k / § a 'r § ■ w z n 0 w a 0 0 £(a /�\ E y % G° ± =z 2 E- =3 aaf » » _ 0 �\a LU \ \ k ] k ±0000 B }\ S© S S g G 2 G G§\/ \§ 2 2 �/ E / =nmm� 0 0= f$ Z3 o$ G f o¢ o 0 0 o g/ .2 \ ƒ\ E / a/ c Q o Q o cl o a aCli n c o 2=m _ z z z z z z z z z z z ƒ >g 0 w Q•.......... ■ 0 . $ 2 f f ■ Q Q :3 \ n n n g\ n /LO a n Lo f k \ \/ ƒ» f k \ c * \ ± \ \ / \ c / / f ) k » O E G , } E § m § ƒ / f _ " ° OL °= w # _.= 2 E m= f 3 2± e 2 R f° a°°% $) E R _= a 2 z R a 2 a ®2 0 0\ £ f® 7 0 J\ƒ\ R$$\ 4 u < » z W < = 0 e u < _ < < = 0 0 ± \ \ C \ iF \ \ 0 ƒ // ƒ ƒ °a) \ § §§ {ƒf ^ ® \ 7 7\ §22 B }\ . U 2 � « � 2 W E Z O > 2 w U) w O � W m W w i. Tr # o Jle > C 2%/§/ 0 m � � zc & E / E J J m p am ` k f ' q $ t « j U ; e0_ CN w ke°°C a C� � E j / 2 0 § CL� < �� w z§ k w a. k \ % a @ 2%/§/ � ¥ z 0 3 z// CL� \ % 7 m' / E m 2 z 0 / < IL }15 \k ak E y/E c Lii \ � � (n 0 2 « � \ ± \ \ ® E m k R ±uC)00 = (] f o 2%/§/ G 3 z// E / § § § f� $ $ Q 2 / z>oa) \ ƒ} E / e c o 0 / J z z z z z f >g 0 LU Q----------- 0 @ 4 0 2 k E / ■ < 0 \ } / / / ^ 0') \ coa- '0 \ \ a/ »' ®- -E i c $ } $ $ f \ 0 & & & J \ ±/ I I ƒ I 0 7 \ \ QCL - o K ƒ G » ® -0 _ -0§ - - _ o f = _ _ k f E 0 a = _ _ f { / / ƒ 2 a®_& t$ e f= n/ k k / / .- $ 7 \ < k \ z z\\\\ m/ z z/ -j < » z � < < < < m 0 < C? C? �r # 3 , , \ \ 0 / ƒ $ ? 0 ± ± / k § S G& z C f - k G G E \ \ / / \ \ \ - cc; f \ % / § L) n z =\ o 0 m LL __/ . U _2 � « � 2 w 5 2 O > 2 w m O � w V) w w k \ a a. z : / .§ » £ k \ CL E / \ 2$ � 2 2 0 G- _ a E E i2 cc e 2 0 » 3 a, 2 0 0) o & C _ 04 $ c. §W�>EtoE 2 ° 7 c cn S \ k / ( a "r ( ■ w z n in w a a : / .§ » £ k \ CL E / \ 2$ S 2 0 G- 0&& 2 zƒ\ E 0 §§§{/ 0 g 0 0= o= 0 o 0 0= 2222 /ƒ& E / a? Q o� o Q o c o c M n Q . z z z z z z z z z f �k 0 LU Q--••------- U) 2 �� ■ Q Q Q \ } ® / 2 / @ < r / 2 / - Q0 \ k \/ E \y - \ i/ \ 4 __ E \ _ \ % # / % 0CI-= } a= ± 4 ± f E 8 4 ± E e m E § ; = \ = ; 0 e \ / ƒ o o - E % f \ « k f 7 8 f 2 f f± 3 3 \ a \ \ ƒ \ : \ \ 0 0\ 0\ 0 0\ 0 0 0 u< x±± < m 0 0 w<_<= 0 0 w \ C? 4 S 0. \ \ z ° � $ \ \ E � kEke Cl) C0 §0z \ \D Z) CO 0 U 2 � « � 2 W 2 2 O � > 2 W Cl) w O LLI� U) w w q m � 0 \(a \ U g L:E z 0 ± E __\ k D»_ 0 2 u \ a/ _ cu± ±o0ocl/ \ ƒ k k E $ \ � S 0 S g § S u g \ 7 \ ° 0 CL / E J J °0) \ 0 _ _ �Mf 2 _ a) co CD o ; e0I C14 §§§D $ _ @ §��>E > c 4), CD co \ (/ a � ) 2 ) w w z n Cl w a C 0 \(a \ U g L:E z 0 ± E __\ k D»_ 0 2 u \ a/ _ cu± ±o0ocl/ \ ƒ k k E $ \ � S S g § S \ g \ 7 \ / / / ƒ} E / § A m ƒ� o 0 o g 2 0 g o g 2n04) o / /& E / ) 7 0 0 o c o o� Q® o § z z z z z z z z f > g ow Q........... ■ 0 . e k 2 k k � Q u \ } © � 2 / a = S CDS \ � \ t \ \� «f fk \ \& =b®® U) \ 0 I f f f \ \ / \ \ D \CU - _ ƒ M j f 9 ) _0 ƒ _ _ § / \ e = _ $ / _ E E # E 2 § % 8 8 2 f± f S f n/ a J $ $ \ \ \ $ \ \ : < \ \ \ \ \ \ \ \ ] \ z -j<>-Lux < = o 2 < < = o < in 9 0)ƒ � 5 / k } \ ) E G E e e ° § § / M ƒf k EE i \ ¢ \ 7f L)22 / / a 0 U 2 � « � 2 W 5; 2 O > 2 w m O � m w w w m � E \{ _)) ,aag ;8 y E } \ / ;o o t //E ,aJe zee o L) a ° E E R I j �/ a ]o$ \a§2m 41 > u ■ > E w w \ k / ) a - w w z n 13 w 0 / \ \ E ¥ Q k 232 E t5 t5 z .° .° _ 0 /a CO ±00025 � k 0 »E . § § S a a N \ uk ) /\ ( \$ S ES 2 z]ƒ ƒ§ E / § 3 ? ƒ� S G G / zfo0 \ƒ\ E / a 7 0®® o Q Q o . z z z z z f �k 0LU Q.......-•-- 0 2 _ 7k ■ @ ■ S S \ a- © ©» 2 © 9 / 3 \ » \ a/ »u »a CA c: $ /\ k �A = \ a) j fm E _ 0 \ o \ S k o \ _ & E c = ƒ m ® Cl- 38#/\f=C c 5 ± a a 2 a f§ 3% \ : \ \ < \ J / % \ 3 \ \ z \ § \ / u< x u W <= 0 2 < I< y � CL CL \ \ cu � \ \ \ \ / / < < m m �� \k} u u = u \ \\ \ $ \/ . U 2 � « � 2 w m 2 O > 2 LU Cl) w O � W Cl) w w ca 0 \\a E ¥ 2 \ z 0 3 §\k z£EE \§$\ LU 2(D w 02 0 o S 2 CL 2 v e e E E R t \ � 2 f 3 2 k k k j\ CD/c§§$ § c.&moo % ° « LO Ui e>ES E k k / ( a § UJ ■ w z n 0 w a D 0 \\a E ¥ 2 \ z 0 3 §\k z£EE \§$\ LU 2(D w 02 0 o S 2 E G 7 f /% / j\ E / G@ q 2� o g o g o 0 0 zchoa) ƒ} \ E / 2 2e�zz z z z �§ C 0w Q........... 0 j 2 0 � Q Q \ } 2 \ \ \ k f « a Q \ 7 / k .2 \ \ \ § \ \n & k &\ k ƒ EJ U) % { t \ ) \ b \ f G ) f E ± \ E \ E R\ -0 U)__ / S 70% E k 3 £ \ \.( N ƒ 8 :t! f \ 7 \ k > « < \ \ \ \ z / / z / =<¥zll� <=02 << < E \ / \ \ - a n \ 4 $ CD \ \ \ < \ / / / / \ cD E E -= c o w \ C)$ z / Of 2 W/ / \\ 0 U 2 � « � 2 W 5; 2 O � 2 LU U) w O � w m W w w m « e � 2 0 � 0 CL E R J j � a) 2 ]oma — >'cn k cm ) 0) > � >E§ 2 k 0 / ( a ■ w z m o w \ \(a /#k E ¥ 2 Gm -0 z E C -as/ »» Z; _ 0.. \a m £ « 2 £ E3±fa% ly-eoo2» � k $ E o § a a ( 2 S S $ $ g - 2 ƒ — / zƒ\ E / § 3 § ] / ? S G LQ G $ zmo;� ƒ} \ E / _• z z z z z z z k �E oLU Q........... 0 k �� L) Q \ } m r o = 2 / / \ \ f/ e a® ca ± ® C 0 \ 7 2 _ E 2 « \ 7 ) o # w o % / / \ & 0 ƒ \ / ƒ / $ 3 S # c R = 2 5 3 2$% ®© G z f e s e« e a < \ \ \ \ \ 4 o $ 4 _ < x ± af < m e c E _ < < < \ # § r \ { P 2 \ \2$ $ $ g I cn °� \ CO r_ / i/ 0 a) \ /&a L)22 s U 2 � « � 2 w 2 2 O > 2 w Cl) w O ƒ (n w w Tr k O S rL % m0 G S S § 0 E / E cr.2 ce ® e 0 I § �\� \ Q ; �0� C14 $ §§§%�� $ k @ ± c o . >kco#f IT I = © o a) (D w m§ a I z / r; w■ w z n o w a o a \ » � S $ � $ G S S § 2 S S k / ƒ .2 % \ N E 2 = j z / k \ §\k j. \ \\§\ mm / < \ \ ° E m ƒ b b b / ( ] � S $ / $ G S S § 2 S S 12 ƒ z/c E / cw=; o 0;£ a o o g o f o 0 0 2 0 0 o g y222� /ƒ& E / a/ 13® in ®o O c N o 0 0 C o m— z z z z z z z z z f �A 0w Q........... 0 ± 2 ± $ k 0 k § Q Q o Q \} z r n// r r< g/ a= S \ \ § 3 2 \k 06 \ £ �) �� �A ƒ \� f5 f 7 2 ) o r 0 f m$ o \ k # _ § R \ { \ 7 M � \ § ƒ o \ CL E , o � G ƒ E e 2 3 E E/ E\ E // 3\ 2 / o= f m o n o% \ $ \ k o o w o cm o\\\ o o o\ o\\ o\ _<» w X < CO o G u<= o o<<= e \ � 9 2 j \ \ 75 \ / / 2 / \ » » {EE 7/ \ \ \\ §22 °Q J ° / $ � < E 0 c L vi 4 C a 3 � ti C Z a a 6* � c w Z O E � r r E a W a �3 d N r LO d (� cm R m 1 1 d Eco W 6W N W a� G�� 7i L O Q O 2 LLI _ c $a O o r LL " 1 O o y siau!muoo # U Z Q rl n H u n m .o a 01>00 xujeW 1 U f E L. � a --_- -- -- (I ri Q v a easy I ('1) E Zp awnloA aldweg 0 M u ¢ CCC G MON i13H10 _a0 SIVI11Nl S.a3ldWVS -- -`--- �► _ N „� __ UOUBIII _ Uen til 0 ll� leow;uaPl -I- PWW c CA l,J -- UOgemi iuenp io _ 1. W 8 A Iw r l ca �v v Q uope0yquenp to sname S __ uooe0lyluenp m -t+ Su11011100 S .2 O i� ZDh CL uo4e0yguenp jo -I+ :N003 m uoliebr}puenp to -�+ :lunop eieed olQOJaV m +n • - m w Z -1+ Eu9141 .-+ G < _ •1+ LH:LSLO!WIIB j11 1� v o W F- __-H^'etleuow�e8 " II, g G a R W .--------- H13W-SOINVONO '� a u �_ CY_. ue�5 sfelaW 'awnj WPIeM `d101 I Vaaa '\ uj (s)a3NeUV - SlV13W swildsea 'moi - 1SnO toQ 2 VHSO '8000L 'VQOP'L WOd L - n W a. sdatd i>ejIPul-OSI '0en-omW luenb lueaS u W U. : -• Wenp ,/+'OSI 'ZO>L 11 lena1 'Va3HV - W31 6uol 'Podet �.. Q luno, lulod uodei uo4S Wld \co $W_ a _= ► 4 1 aw E I a r, Z Z a r •I L E7 e C �r clm e. a d a L] E x E E T )io n x T r' m� WCL u Er+°3a N Ea �. D D ACA ( LqI r MI L M ITE V pp 'j Q 11 W d cll Its m p> ti i Z7 Q I 2 E IL m� Z R O _ r~ •x �j V r _� a,x O I O c 2O w w 3 i Wm o m m 3 A n 0 .aa � U d m LL7 a O H m O i tII _E U N u m 0] ¢+ n r 4 F- v z L CO a m U3 X 0 L) 0 c ry ; c U N II II m U) W = 0: E R m U ) U G E? 4! m o a D d a d Q a U f x aL O i W to $ 'A - E c L 4 C a 3 � ti C � c w E E a �3 R O C 1 N a� G�� �LZ _ c $a o r SL V) Z fVV U f E y r p Z 'c E sri Uj 0 o Z ED z w uj CO Q, 81 E 0® CL, 2 0 C3 In ajoul LnUOD N :2 < ol SPOO)WVY eajv i N <o y' in oA oldweS :S31ON V31uO NO SlVtJJNI S.V3ldWVS LsomoiAueno jo -1+ :wig jo doil 9jodS PIOW linuawuw1w3Jo -1vl,u9prp" AWO uow a*WWeno to -1+ wilsuolOal In to uo!lvm.Auonojo-/. !WgA jo eustwe,pnoo alelj oiqwov tjwmt) I"qoj3M g < owmaWluvno jo "-IP-IM-3 Z uj uoq"MjuenDjo-j. jq=uqoKoweo'—neS elielsil 'LH:LSLO —I=3'fflPuOwMS:$uGSOtARd i t cn LU H13H - SOINVONO ui uvaS stelon wjnA 5mploM 'diol '8 "38 (S)VjAfeLr%f * MUM qmjsdsoa mial - Isna VHSO '8WN 'VWtL . Mod sdOld i-JVWOSI WOrb-lu*S luenO '-/+ 'OSI ZOlL 'll IGAGI 'Y89HV WY31 t I lur*–OW.d– IMW BUDI IJOft NWS Wld C, GZ cl It j .0 :14 0 Wy R4 C , . ZZ: It f I , ' I I 1.. v:� , v —1 I q I , -4e -) -�j %NC) 110 r z, A �4 4) 0 ui of U) V L I 1 -1 IV 1 0 " r– " co N Of_0 W I I f f Q Z { I F t coI QL W I ! I M � I I W10 0� OC7 rn'ffi Slau,elu0p# J Q ti 11 apop vilely f ! I > ¢ —. eeib' t (I) awnloA atdweg ! ! :S310N 2131i10 140 SltlI11Nl $,2S3ldWVS u04e�pluenp jo -t. .HMS 10 detl wodS .PIoW� le;Uewuw!nU310 IVI "ueWngo!S j8410y U011MYluenO JO -/. W 8 A N 4 } io eualae8 'luna'J 87eld o!gmey :We+wfl lelgonfn ougeJJ4Uenp 1O -/t MWOJ,10J JOIPue 11093 I I I I j f I Z uoq",j4uenp do •1. :f I-goj4dweo '-9j-'S W 'euals!l 'LH 'L9:0 4073 'e118uDuJPS SUGBO Ild — U.1 H13W-SOINVONO Q W Lien,, s!eleW '0—:1 Bu!PIW,, 'dlO.L 'e "021 (s}WIa UV - JS" IV13W I I i I '!elol emoildaeb - lsn0 VHSO 'eoo>L boOYL • WOd sdaid MIPUl-OSI'oe^-on±W wenb-pneS luenp -ta 'OSI 'Z07L 'II lemel 'NM3HV - W31 IunoO iu!0d lmdei Buol 'uodw u04S - Wld �}�I C■`'l~� � i J I : I Q. QLL ci r WE ■Iry ^��,;�, i I i ': � I 1 ! f %10 i s _Ocl 0 Im5 I LU 'Q �! N P! m A OO 07 O N M Q U7 U7 h� DO Qi q N M' Sf N tD h� W 01 O Q � V r N N N N N N N N N N M M M M M M f+7 M M M et V V c 0 vI N v Y� d .r PERMIT NO: JOB ADDRESS: JOB DESCRIPTION City of Wheat Ridge Commercial Asbestos Abatement PERMIT - 202000547 202000547 3760 Vance St Commercial abatement removing square feet of drywall. ISSUED: 03/10/2020 EXPIRES: 03/10/2021 100 square feet of ceiling tiles and 10 *** CONTACTS *** OWNER (720)936-5131 KING DAN SUB (303)481-8234 VICTORA GARCIA 180013 MILE HIGH ENVIRONMENTAL SVC *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: 520 / Office; 0 USE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 3,000.00 FEES Asbestos Abatement 50.00 Total Valuation 0.00 ** TOTAL ** 50.00 *** COMMENTS *** *** CONDITIONS *** All work shall comply 2012 International Codes, 2017 NEC (if applicable), and ordinances adopted by the City of Wheat Ridge. Work is subject to field inspections. I by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of theproperty and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be perform a that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. l C) Lu `�Lt) Signature OWNER or CUl CTOR�Circle one) Date I. This permit was issued bas of T a 4MMrmation provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or grantipg of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or anArdinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of WW .rJ+"C.c)fvtLlttNiT`r" DrvEWP/v1i:N Building & Inspection Services 7500 W. 29t1 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a�ci.wheatridge.co.us I FOR OFFICE USE ONLY I Date: 63//d / ?oZ o Plan/Permit # ,::1:, 026 f3bsy7. Plan Review Fee: Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 51 �PQ mu s1-. Owner Property Owner Email: Tenant Name (Commercial Projects Only) )cv-\ V_.1 *Nq Phone: CL Property Owner Mailing Address: (if different than property address) Address: 3-1too m(e_ mi-� -3 c, City, State, Zip: 0CC-1f P6 dqe , CIO, e�W 253 14 AMhitect/Engineer: Kenc� 'TQ MCS t nqI o cc is I n CI Architect/Engineer E-mail: Phone. —0 -1 Contractor Name: IV I i IC tl i l>II I r-'( IV I r C11 IC Y ►C r i-Ui �C r V / CC,\ , 1 I City of Wheat Ridge License #: 1 b o o l Phone: J� - `- 8 j B2s L� Contractor E-mail Address:4mCC+ Ca nC+a S For Plan Review Questions & Comments (please print): CONTACT NAME (please print): .f'll'� c��i� Phone:�� �I�y CONTACT EMAIL(please print):��f�� ��P���tO Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields, if applicable. XCOMMERCIAL ❑ RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. rt CCU r Sq. Ft./LF 1:0%S , F• BTUs Gallons Amps Squares For Solar: KW # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ �, o Q O ONVNERXONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that i assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER)(CONTRACTO or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): DATE: 3 J Printed Nametyin Y� DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: CONSTRUCTION TYPE: Building Division Valuation: Godding Pkwy llow EARTH EN ENVIRONMENT 5366 Longmont,°CO 80504 Local: 303.478-0922 Industrial Hygiene and Environmental Consulting December 8, 2019 Mr. Dan King, P.E. Reno James Engineering 4900 W 291h Ave, Denver, CO 303.800.5105 Subject: Asbestos Inspection Report — 3760 Vance Street, Wheat Ridge, CO Dear Mr. King: Earth Energy Environment (E3) is pleased to submit results for the bulk sampling at the commercial property ("subject property") located at 3760 Vance Street, Wheat Ridge, CO. The sampling was conducted on December 5, 2019. The sampling was conducted for the purpose of determining if asbestos containing materials are present in the building. For the survey, samples of surfacing material were collected using the EPA random sampling protocol outlined in the EPA publication, "Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials" ("Pink Book", EPA 560/5-85-030a, October, 1985). LIMITATIONS This investigation was conducted and the report prepared solely for property owners. No warranties for other uses are applied and intended. Evaluations of conditions at this site were made Survey Report 21Page from a limited number of observation points and conditions cannot be warranted at non - observation points or non -accessible areas. The sampling included the suspect asbestos containing materials based on visual observations and discussion with the property representative. Interpretations and conclusions made in this report that pertain to the asbestos are based solely on results of independent laboratory analyses of the samples taken at the property at the date and time indicated. E3 has no control over such testing and analyses and, therefore, disclaims any responsibility for errors or omissions arising there from. INSPECTION RESULTS E3 sampled forty-six (46) homogeneous areas, as summarized below. E3 collected at least the minimum number of samples for the homogeneous area necessary to meet all regulatory requirements. Homogeneous Areas (HA): Homogeneous areas were selected from the building materials observed during the site inspection. The homogeneous areas sampled during the inspection are listed below. HA Description Friability Material Condition Potential for Disturbance 1 Exterior Brick Mortar Friable Good High 2 Block Coating (stairwells) Friable Good High 3 Unit 200B Walls Friable Good High 4 3rd Floor Hallway Walls Friable Good High 5 Unit 200B Bath and Hallway Friable Good High 6 3rd Floor Ceiling Tiles (newer) Friable Good High 7 Hall Ceiling Tiles (older) Friable Good High 8 Front Entry 1 st Floor Walls Friable Good High 9 Unit 301 Walls Friable Good High 10 3rd Floor Stairwell Ceiling Friable Good High 1 1 Cove Base Glue Non -Friable Good High 12 3rd Floor (above tiles) Joint Compound Friable Good High 13 3rd Floor Stairwell Wall Paper Wall Friable Good High Survey Report 3 1 P a g c 14 Unit 100 Walls Friable Good High 15 Roof Mastic Non -Friable Good High 16 Unit 200A Brick Coating Friable Good High 17 1 st Floor Storage Room Walls Friable Good High 18 Unit 100 and Unit 101 Walls Friable Good High The laboratory separated and analyzed individual layers within each sample, if present (see Attachment A). Table 1 provides a summary of the homogeneous areas, associated samples numbers, area description, classification, material type, and laboratory description of the sample makeup. Table 1. Sampling Results. Area Classification Asbestos HA No. No. Description / AHERA Description Content Category 1 1-2 Exterior Brick Misc. A Off white mortar No Asbestos Mortar Materials Detected A Off white/multi-colored 2 3-5 Block Coating Surfacing granular material No Asbestos (stairwells) Materials B White block filler w/ Detected light gray paint A Off white compound w/ light beige paint 3 6-8 Unit 200B Surfacing Off B Owhite compound w/ No Asbestos Walls Materials Detected cream paint C White/tan drywall A Off white resinous 4 9-10 3rd Floor Misc. Materials material No Asbestos Hallway Walls B Yellow wall covering w/ Detected off white paint A White paint 11-13, Unit 200B Misc. Materials B White joint compound 2% to 30/'o 5 39 Bath and «5„ C White compound Chrysotile Hallway D Off white tape Asbestos E White/tan drywall 3rd Floor 6 14-15, Ceiling Tiles Misc. Materials A White/gray ceiling the No Asbestos 41 (newer) Detected Hall Ceiling Misc. Materials A White/off white ceiling 4% Amosite 7 16 Tiles (older) "5" tile Asbestos Survey Report 4 1 P a t Front Entry Misc. Materials A Off white compound 2% Chrysotile • 8 17-19 1 st Floor 5„ B Brown/off white paint Asbestos Walls C Off white/tan drywall Surfacing A White joint compound 9 20-24 Unit 301 Materials B Owhite tape Off ° 2!'o Chrysotile Walls Asbestos "5" C Off white compound 3rd Floor Misc. Materials A Off white paint 2°% Chrysotile 10 25-26 Stairwell 5' B White compound Asbestos Ceiling C Off white/tan drywall 27-28, Cove Base Surfacing A Brown adhesive 2 '° Chrysotile 11 Materials B Off white/tan drywall w/ 40 Glue "5" off white paint Asbestos A Off white tape 3rd Floor Surfacing B Off white compound (above tiles) 2% Chrysotile - 12 29-30 Joint Materials C Owhite joint Off Asbestos "5" compound p Compound D Off white/tan drywall A Off white/multi-colored 3rd Floor Surfacing paint w/ a trace of white No Asbestos 13 31-32 Stairwell Wall Materials compound Detected Paper Wall B White/tan drywall A White compound w/ Surfacing gray/multi-colored paint Unit 3° o Chrysotile 14 33-34 Wallis s Materials B Off white tape Asbestos "5" C White joint compound D Off white/tan drywall Surfacing A Black tar w/ gray fibrous 4% o Chrysotile 15 35-37 Roof Mastic Materials material Asbestos «5„ Unit 200A Surfacing A Gray granular No Asbestos 16 38 ementitious material w/ c Brick Coating Materials Detected off white paint A Off white tape B Gray/multi-colored paint 42,45- 1 st Floor Surfacing C Off white joint 2`%o Chrysotile 17 46 Storage Room Materials compound Asbestos Walls «5„ D Off white texture E Off white/tan drywall A Off white/multi-colored Unit 100 and Surfacing paint B White texture 2O ° Chrysotile 18 43-44 Unit 101 Materials C Off white tape Asbestos Walls «5„ D White joint compound E White/tan drywall AHERA Category "5" = ACBM with potential for significant damage. Survey Report 5111a e SUMMARY AND CONCLUSIONS According to the laboratory analysis of the materials sampled, asbestos was detected in the following material types and areas: • 1st, 2nd, and 3rd Floor Textured Drywall Walls and Ceilings • Cove Base Glues • Roof Mastics • Ceiling Tiles (older style) The Colorado Department of Public Health and the Environment requires any asbestos containing material greater than 1% that is friable or will be made friable during demolition activities be removed prior to demolition by a certified abatement contractor. Any other potential asbestos containing materials identified in the future or during demolition that were not sampled in this, or any other previous survey, should be tested for asbestos content or assumed to contain asbestos before being disturbed. If you have questions or require additional information, please contact me at (303) 478-0922. Respectfully Submitted, EARTH ENERGY ENVIRONMENT (E3) Arthur Willden, P.E. Engineer / Industrial Hygienist Survey Report 6 1 P a g e Attachment A Laboratory Results Reservoirs Environmental, Inc Effective Apo 102, 2018 Reservoirs Environmental OA Manual Q:\QAQC\Lab\Reservoirs Environmental QA Manual.doc REI LA,. B Reservoirs Environmental, Inc. December 06, 2019 Eli Willden Earth Energy and Environment Corp. P.O. Box 348 Frederick CO 80530 Dear Eli, Subcontractor Number: Laboratory Report: Project #/P.O. #: Project Description: RES 451109-1 None Given 3760 Vance Street Wheat Ridge Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 451109-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, d by Josh Baker Jeanne Spencer President P.303-964-1986 5801 Logan St, Suite 100, Denver, CO 80216 1-866-RESI-ENV F:303-477-4275 v+r✓nv .reilab.com U z_ J Q H z W 2 z I.L z W cn W U) W w L J .7 Y 0 0 0 0 n L) t z D m O _ E d n o a c i c m u LU m m Y COP o J w N �_ N .0 a to N co C d Q r N jC y d a Z Li i� m E E 0 Uw m o 'r- � 0as 0W wLUzv)❑Wd❑ U) CL 0 E 1.' V) 0 0 0 0 0 J 0 0 0 0 Z O 0 0 0 0 Y a ami 0 0 La > N T O E U N Q Z ❑ J E z 0 w wa U) 0 E E W o J a s m o U o 00 cn Co (n C C C 4) m N C N N N F E U 5 5❑ H❑ C Z 0 0 0 0 0 0 0 0 0 0 0 LO O C O 0 0 0 0 0 0 0 0 0 00 O 00 Z N O LL d E O U 0 0 0 ""' 0 7 C 0 0 0 0 0 0 0 0 0 LO 0 LO Z w O N" OC -C.-0 LL D_ Q 0 U C z z z z z z z z z z z z H/0 E 4+ > w N 0 w a .1✓ ,O C Z3 m oO N r d' (p O (0 (O M U) a m 0_ 0 0 U i 7 cn mE O_ C m C C O C O C_ U O. a CL (0 0- O) '� @ O_ N T U O T (0 T f6 C T N L E m U L in o- a) C rn rn N rn L m L rn ❑ 0) L L — U 0 rn a)m 3 3 3 _o) 3 3 0 3— �c m 0 0 3 —0Q N N O O m O 2-• E E E E E E U E U o o o U 76 3 3 0 0 0 �D 0 0 0 0 Q w Q Q Q m Q co Q Q m U Q m N M (6 (V (0 N U U U N 0 m 0 m 0 m — j am m m w N y tfV.m O O m mm O m O d 2 (n (n (n O O y. CL N am E E UU U U U M= m m LE C C U t z co m m m m J ❑ 0 m N 0 b aw O (D a) W O a) O L) m m J a Q J z afft� W J m Q H 0 � c . o L U U E U) m Z 0 E t5 tU' z a) a) p _0 L O O E C: O a am o -) O W) ac) a c N T m c Q U) a) d E m U) a) io 0 C j w Y Lo a � LO O m 0 U t I— O 0 M a Op o O O E CO O c ° o O O m c 3 (A W M a) � O r r N O N r' M W OT1O O O O > C O rC Ln LU a a t w m d cm o d C m ti (D 4) E 0 � c . o L U U E U) m Z 0 E t5 tU' z a) a) p _0 L O O E C: O a am o -) O W) ac) a c N T m c Q U) a) d E m U) a) io 0 C j w O Lo O LO LO O LO 0 0 00 I— O N Op o O O M CO O M O O O m M Z L C LL O Q E O U 0 p 7 C O m O M 0 0 0 0 0 00 ZOO () a)c L O LL O. Q O U i6 .m+ 0 0 0 0 0 0 0 0 0 N M 0 0 CW R z z z z z z z z z z z > O W V 44 d d O 0 O � U U .o tf O m o M M M n 00 Cl) O N m LO Lf) LO cn a C_ C C � O L) Q m a) Q T L) a) 6) 3 L U) aC) MC- 3 C r- o 3 0 = m _0 'Op @ 3 E m C 0 0 3 Z a) C - p o > c 3 E o .� M '� 0 m LL) o_ a Z 0 a) d U L O_ C E- _6 a) @ N a) LO a) « N O a) @ 3 3 3 3 o 3 D .0 cEa 0 r 0 0 0 i 0 0 0 J Q} W W Q m U 0 W Q m Q Q m U 0 W m Cl.) N a) U N U m mm 2 O z m m p U a)O m O O w ID t cacli 0 O O -1 ami E E .J U to z co co N 0 O W Mm a Lm U z_ J LQ r z w 2 z O z w Nn�y LL LJ. w w w O (O Of co O a1 0 O U m J a Q J 2 0 a O N a).a> U Lm E U0 Z ❑ EU 3 U U a) z a) a) a .❑ o a E 0 a a in C C C p L L1J a a d) N a) � U U U ❑ � ' U Uo o Y CL O m N U t V C O a) E 'O y C o y m O a0 . c O L � � a0 LU m a) m r m 0 d o N o (14 (0 >, r U) L M t0 Of = a) O O r C Lu > CLo 0 0 �a �-0 C9> d v L E(�o. a o y �- E a) W R O n ami d 'L ami w w Z m w d ❑ 0 a O N a).a> U Lm E U0 Z ❑ EU 3 U U a) z a) a) a .❑ o a E 0 a a in C C C p L L1J a a d) N a) � U U U ❑ � ' U Uo o w O N V p 2 C O) O a0 a0 Z o a E O U C U U U o 02 15 L() LO O O M (O D Z U) '-' O a) a0 a0 co a)C -0.- o QLL a E O U .0 N a .'\� z z z z z E > r U) d w .......... m .ir 4) Y O .r N N O Q U tC -� -0( 3 m o O 0 o 0 0 0 (V (1) LO 0 (n ! m a Q) O O U i 7 c E m O U d N a) U7 a) N () a) a) ._ U) 'C > U 3 Q 3 3 a) 3 Q a a) m �O c T) c ? m a) a) U U _:@ m U U m a a a Cl= — a) a -a o N (D U U EO L 3 C N N C >, a3 @ 3 U >+ >+ :U N _>1 (D 0) m 0 N O a) M a) N Q Q a) m a) 3 3 3 Q Q 3 z z �S O O z z 0 co -i Q} LU W Q Q Q Q m U Q _ c LL (h Y C ma a - LL LL LL O w — O m = a) a) 0) ? co O co O C y a) O.= p N o N rn C Q) C Q) U w w w o co ya E E + . __ 'a) Za) __ — c c c 'C m 3 C C m O O O U to z M 1) U U 2 LL LL LL:D m 11w J U Z_ J `Q r Z W 2 NZ I.L Z w N0 I.L W cn W w C7 (D a) co O d 6 O U a m J IL Q J z W J m Q H a) rm � C N O W — U m -O u1 a7 O Q1 o E N O V F N Q) II C U U O f0 Q z ~ E C, E z F L- 0 (L C O-0 � _ N 0) �U U .. E N m Z ❑ E O U U N Z 0) a) p_ '0 -0 O O E 7 o a u O wC C C N� E 3) L1) .°) m 0 U U 0 H N m c Q N d E m U) a) m C j Y Y O CO O N O 00 O U L'- L— N O � a O E O) O o a cm 00 s M c to Z w m ' N r (p m r = N O r N r O N m r w M O)) O 01 O � C LL OO_ > m O to w La EE .0 e}t y> p a) w m o ti ami a. o 0 W W Z M O W L1 0 0 (L C O-0 � _ N 0) �U U .. E N m Z ❑ E O U U N Z 0) a) p_ '0 -0 O O E 7 o a u O wC C C N� E 3) L1) .°) m 0 U U 0 H N m c Q N d E m U) a) m C j Y O O CO O N O N O O L'- L— N O O c O � C rn 0 O) O W O 00 O M 0) 00 Z ca E 0 T m � C LL OO_ _U C m 01 O O 0) S C 0) E E 0 U m m� _T m C �Y or a c^ m� o 0 LU O U 0 0 \ O 0 O o 00 O CO 0 0 0 0 00 Z in O a) NC n. -O Q LL d O U R w o D N o 0 0 o a a 3 La's. Z Z Z Z Z Z Z Z Z G L O L to m a1 m 0 0 0 = L U L U L U 0 0 0 n o 0 0 U) a o c cu Q a) O C O U m O- m .O O N U Q O T U O O IL a) � c c "0 C 0 _� T m 0 O CL _ 0 -0 3 3 E 3 E Co c 3 Z a) 0 0 a� c� OU a N _ C C6 d U d E C �6 3 C Y6 d N X C U N N N 7 N N 0) °- 3 3 a) 3= 3 3 3 3 3 0 0� 0� 0 0 O O O C7 J Q} W Of Q m U❑ W Q m Q m U 0 W N m C? N N U _U V O LU Za) m a) ctj U 3:E d ` o o C as m m E E t - o U to Z U) zoW W2 o m N U U 'c 0 m o m V m v a) m O N � C rn 0 a m O 0 ai m ca E 0 T m _U C m 01 O O 0) S C 0) E E 0 U m m� _T m C �Y or a c^ m� o 0 LU J U Z_ J LQ r z W 2 Z Z W NN w 55 W U) W w m N N E= N O LL c) 3 Q -O n N Q) > w O u") a E ro 0 v CL) 61-1 C U U O m Q 110 Z H F- O 0 m .a .> L U U E in m Z 0 E C U U a) Z a) 0 a L O O E () M 0 .. U) O C C C O L LU .°) .°) .u) M m w U U U 0 ,�-,-�2o O O O O co 0 O w O U � c of O O O w w E R w C 0 0 Z a) 0 d m c W a1 r CD 6 r CD L Orz a N T M a) O O CCD Ln [1 W > C d G t6 U' d > E m E (n C Q O � W0 z W c0i 0 W cn 0 CL. O 0 m .a .> L U U E in m Z 0 E C U U a) Z a) 0 a L O O E () M 0 .. U) O C C C O L LU .°) .°) .u) M m w U U U 0 ,�-,-�2o O O O O co O w O w m O O C O O O w w O O w O V Z a) L Orz a E O U C N NN^ O O C o 0 0 0 0 x 0 0 0 0 LO O Z in o a) ' N N LO a) c -0.- O QLL a E O U ❑ ❑ ❑ ❑ ❑ ❑ N ❑ N ❑ 4.07 td z z z z z z z Z H E C � C w q1 d d O N O N a7 C t L U U D a3 c Lo lf) 0 O N OD O V (O cn a C co a c 3 c c 0 � n ' � O U �- fn r T U C '� C '� L 3 L C cr a a s o a) a) .� o o 0-1 L 3 L 3 a 3 m U _0 C: -00 c IM 3 3 3 -o c a) 3 a � -0 -0 0 a o a a) .� o a@ w a) @ o a) c m coca a L N U U _ O _ N U � M .� C 0 0 0 0 O z m` JQ>- LL Q. Q CO 0 0 0 Q CO U Q CO L? ON � M 0) Q) C C C M a) U U 7 _3 (7 E C/) U) w a) of O L O O co a) 0 Q � � O O m m a)EE c "-2 > > c a U N z U M M U U 0 a W U Z_ J LQ f Z CW C Z N0N I.I. Z W NN N W W w C) V7 co O_ d O v a m J IL Q J z N f� N O LU '.E-_, — U 3 Q N _ O mo E � V ~ 11 C U U O Q z�1-1 E O � � ZF-H Y CL o m U aa) o O a E R C r ° m o C W m •3 y •' co o r- 10 01tmOM C d _CD >_ y r d ►p W (7 > E cn C CD W v Q w CL X LU W Z M❑ W O 4 c . o U U E cn N Z 0 E O U U N Z ) a) a OO E 0 a a m -0 C G C 0) 0 W aa a) L6 O) w U U U 0 � v N T m c Q cn N O a E O cn LO E N H D C j y o O c0 a0 O O O N O O O O 00 O 00 00 Z .oC IL O Cd C O U C (n (n o V O O O O O O 00 Z conn 0 N O) N N O) C QLL O_ E O U w ❑ N N ❑ ❑ ❑ ❑ Z Z Z Z Z �v > E C FA LU ......... syw' m m A' r N r N d U U �tf :3m o Ln m LO o Cf) a O N U C U T (j ami a a 0 a 'C a0)c N LD n a_ m Uo (L) � o a 0_ E a .o m 3 m o :o c M N m E7ib-o70 Z m m m c 3 3 3 c a 3 a 2 'o3 T O O O O Z O LO) C7 JQ>-L11Of Q m U❑ Q m Q N N N n. N Q N a cn a c 0)m m Z U U O O '� m Q Q in QI d 0� C O JJ J J d E E E E LL LL LL LL - -o a -2 Ci (n Z M Cl) M M > Z o W a W m Q � m c J 0 i a) a) O O aaa U U U O O o p 0 C c Y I- O CL O m O c0 O O O O Z U C c o1 O E C O` m L O � C m W w m � r N r N R '7 r (n ch O 0 W > V >_ C C9 > Eco E (n C Q O 0 LU 0W CO.) W W Z M❑ W n. ❑ i a) a) O O aaa U U U O O o p 0 C c O O O I- O O 00 O c0 O O O O Z O C). E O U C 0 rn O o O O O O O O O Z in a) " O N a) C L — O Q LL Q- E O U r ❑ ❑ M ❑ ❑ ❑ z Z Z Z Z HO E Fi > i= C N 0 W N d 44 O O C U U -Q- 0 m o LO L � 0 0 0 0 (D 0 U) CL C cuQ a) � L 3 cu 0- __ _0 3 C O N OU Ul a3 in a) a — 'ul a) a) (0 T U LT @ 6 CL E cif o p U) `01 C a) m: O 0 t-- c 3 o _ m U U O 3 Q ` d U 0a _0) 0 U 0 m cl E m C m T 0 .0 T C O m o a) m m m m a 3 3 Q Q T N (6 O O z C7 m Z (� - Q >- W W Q m U 0 Q Q Q 0) c m 0 U Y U m N N i UU U >O >O .N - O O r- Q O „ a..0 O o ami E E - 0) 0) 0) U to Z > > O Z o W to m W � 333 cmo 3 C9 3 m N m t < 3) 52 ) 0 a U 2 � « � 2 w m 2 O W > 2 w Cl) w 0 w w U) w Ix }} co 0 m -i § ƒ w ■ D -i O % m � 3 £ z 2 & E / § 3 J 0 2 = a 7 § § q 2 f \ o; e N _ 04 §§/ k r4) « _ ; U z_ J Fa - z w 2 z O I.L z w NO w O w U) w w 0 1D co O ai O 0 U a ns J a a J z o Y CL O m m 33 U t Z0 D aa) a ° E O N o m c c m 3: U) LU VC R r o w N r N W r T (7 a) 0) I) L Cl) C a) G G a o a)> H G u d m ,M Z Lo UJ � E c E LU U)c 0 Q 0 U o 0 0w 'r- ca o r w a a) Ww W Z co Q W d Q IL 7% :3 y o O w O m N J O m M O O Z O p p C O m Y a ate) O O fl_ > N O U _T M E N a) Q Z ❑ J E 0 n d .z Q Q 2 O Q E E E 0 E J a a m a o� o y O m In m a) a)L C H w U U U❑ 2❑ E :3 y o O w O m N O O m M O O w O p p C O m M M O O O M O O m M Z 2 O Q E O U C O ice. c O O o O O O O 00 O O O I` O O O O N O C Z V) o a) m r a) C Q LL d O U Q N Q N Q Q Q N Q Q Q N Q z z z z z z z z z N E N 0 w 0 ........... 40 a) a) of d Q0 N U) V! N C_ Z) a) c U-) LO U-) �D LO Lo U)U-) of L O N CD U) d 0 `m c f6 C m co T Q @ o d5 0_ 3 c a) co -r- cn ao c 0 3 c Q o y c a L 0 3 0 o C : 3 o — m 3 0 O U 0—-0 O 0 7 0 -0 O -p — .� O Q E O __ 4,5a a� E E O C �° Q= E E Q E o 3 E 3 .a) O o o o o3: o3: 3: 3: J Q >- W W Q m U❑ W Q co 0 Q Q m U N N r U o co � mm LL NUJ LL a) N O m m dE EC 0 0 U vA z ❑ ❑ 0 N t0 N V C q aW Y Lli 0 I M o� CL O J d con L4 ` W x 'J �r`�L may.'.i7 W J tlt C Q CA n m fit r � s u n 2 m C s _-_ E o v it �n _..... „� G __. ._........__... __. _...._ _.. z awntA/E a{sPu1�g s�aars �aa+ia>ao s•+muws s}tBiBW't� uoeeayluenp uotte macs Paty uoneallnusnO 10 uone;jnt�n., eta y. sne3nag uanealm'e o JO v sui ut�to� � uMiUyuenj} sa r+ ta* g _ --------- ...+ 1i i54C9 Ua4"- •r+ m{tauasiatg5 31ti sNVQyLIa .., ue stetaW ewn� 6u� d101, `9 YNON (stat peu star3tre ome-sab eta ' 1sno t~ rwsa 90(W; Voavz w0d '�d r.�e;uw�`�*al '�e�'aratYq a#anisya;e� - luBttp -ry p5: Z6Yi ti tanvt V83kb Wei tunao (wad 'z>odai wl 1awu, uoas - W'ki > i "k. ro IE cav vm i� 2` 3 1" b i � Ob " tu ri -6 E i 1 i" N CS !4' 4t! sC h dtS t7S L4 ` x 'J �r`�L may.'.i7 W J tlt C Q m fit r � s u n 2 m C s _-_ E o v it �n _..... „� G __. ._........__... __. _...._ _.. z awntA/E a{sPu1�g s�aars �aa+ia>ao s•+muws s}tBiBW't� uoeeayluenp uotte macs Paty uoneallnusnO 10 uone;jnt�n., eta y. sne3nag uanealm'e o JO v sui ut�to� � uMiUyuenj} sa r+ ta* g _ --------- ...+ 1i i54C9 Ua4"- •r+ m{tauasiatg5 31ti sNVQyLIa .., ue stetaW ewn� 6u� d101, `9 YNON (stat peu star3tre ome-sab eta ' 1sno t~ rwsa 90(W; Voavz w0d '�d r.�e;uw�`�*al '�e�'aratYq a#anisya;e� - luBttp -ry p5: Z6Yi ti tanvt V83kb Wei tunao (wad 'z>odai wl 1awu, uoas - W'ki > i "k. ro IE cav vm i� 2` 3 1" b i � Ob " tu ri -6 E i 1 i" N CS !4' 4t! sC h dtS t7S 1#i N13W • S91NVJa0 ! I - ....._. __ _.._y.. ( i. . r C] ue s e#aW ^d NOW A101 6 Vt1�23 �ge�dseb .>etal LS#ttl t._ ......_} ..... t g YHSO BOOVL V06V1 Wedi I stisid i�!➢uFC;$1 '�enron�# ive>#• � � �.. _ . I 'Wo,t `i! W0 : 'VNBHV W31 j 1. 1_ d Wd &101 VOdW 1*79 W1d a .. Ts `C s VLf7j) I y 3 .. rA CL ct co 1 ivi J r • W ' ~ { * ' •• Ch 1a r N M rl' IA #p h W p rN M , !p #A �p OD p� C! r N M Me�#� LU ato r r r r r r r r r iV N N N N N N N N M M M M L9 M M w— I m I i z { j 1 w CL� ! vma U. O 3 if C5 v ' „ m saau..etuo yOPOD xuta}Id { faumion iIjdwvS 1 � P !S31oa aaHxo 00 BIVIl.iNi s.a3ld>Rvs UO'nowumo m -7• NMEt 4 d a, t grads:plow I M)Uowua,lta,b,vl u"'No!s "too u0m4w40o4 t+ ,tlllauWstl 1 aG@uat30£3`tu OtBtd H7 t}yYU1otem=m ..... _._. _ z...._.- Ou,te� yw t} 10,b �Jljn wlpw Im 7 �j. is gVojgausnp,>Q -A� .6e1ao40illdwe'J srsa3s� S � suats>l ',;H LS.O 905 3 �i�uOut3M3S �ua504ied l # W HISS SQtkVftO yj S sy aural 6u". dloi "8 vSf ,8 i7C 4g?91d S-1vlawi i ot vaso e�s�c vtxtrt w0a .. .. tuersda.,d s�t'OSI 3tla�0.mW 'WBriD-puU$ itl to OSI ML lHOA91 'VdB V W31 ._._ .... ...... ...... ... ...._ I ... .`_.. , rL it w QAC c 2 1 I 1 { I I I � i i i i f I I � o r 1 I 41tt ........ i o �0 N = w 00 CJ L 00 N ^ X N � y ►I q m z° H = o y x !� U H 3 >+ a U o j bi U ^C t 'd V m Orl bi b C l a .�wa w 4.) 44 r ^l v W o= ed a F o O q a3 M O • ri o sem. ,� o M F •'i W r 4r_ z> o a 44 b 4 x p w y_ cam• Cq V O .moi Gni' O c U C �3 � o�� N >� �' Off" 4' 3 °4 41 q w .� , o w N t Q •'� y do A o O b w a o A O V •d CD v o CG Q U (d G CW -0 U� U i o3s 30 AvN w° Z= 144 - U ��3li 4.) 0 0 r-+ o uCd ^C ro q o � aj 93 a sL'3 oN0.� o ° ami ea Vj M pa• O A b ri 6 � c.� �W oC7 z m•od ro N F as Orl,cr= CL 00 a c 8 UAWo.�" u O ¢QA�oO � b O °r.° y 6 f'V a b w ,1 o l Q^C OOQMO .rl ,d w q o it H b y ~ c E^o zzoaa w u m 0 cows �. Fac 0Uu° z PERMIT NO. 201803282 BUSINESS NAME: Little Tree of WIZYat Riogc BUSINESS LICENSE INSPECTION INSPECTION DAY/TIME Fri., Dec. 28th @2 pm INSPECTION DAY/TIME INSPECTION DAY/TIME ADDRESS: 3760 Vance Street, Suite 101 CONTACT NAME: ~m1 Wallace al lace L109112 SQ FT t; OCCUPANCY TYPE `I OCCUPANCY LOAD I V CONSTRUCTION TYPE ❑ SPRINKLERED r4 NON-SPRINKLERED Inspector Signature 1.2 b'(� Date ! s_ CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 'n+.-; Job Address: '"° C_ L Permit Number: _ k T� I� �r ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: i =' I 1 Inspector: 9 ! OO NOT REMOVE THIS NOTICE City of WheatRL BUSINESS LICENSE INSPECTION PERMIT NO. 201801040 BUSINESS NAME: All School Apparel ADDRESS: 3760 Vance Street, #301 CONTACT NAME: Leslie Weathers eathers 9 t f SQ FT OCCUPANCY TYPE OCCUPANCY LOAD ItTF; CONSTRUCTION TYPE ❑ SPRINKLERED NON-SPRINKLERED Inspector Signature 1-1--3y- /,F Date INSPECTION DAY/TIM INSPECTION DAY/TIM INSPECTION DAY/TIM Monday, April 30th at 10:00 AM nb b a O°O°n o z�i�b z can r mn °����M fD s o O n a moi. rr ��''K w � zpw"��'3� M Wr+ N r" < m < 00 o o m >O�d t> p oj7cn .r C cn p y C P) O H O rn o �j 0 �� S A O O rn ►� wLn Oho �m l?7n; tea` n m �v� f�=•'a' b7 ►d H o' oa o� y� 0 �': O O rz »,C7 rr o0U �o ?fie �. 0 m a. a `° y � C � w mam t7 �c� N N N p Q., � �* g rt y co Cn a A (T1 N O p F,. O m (D 'd Q W .t S tv m 00 :Do OD M H w o 0 o r o a H.+. O '* Q MZ c S m A. M- M 00 r „, �Hcr v�o -3 amp O " n a N. p S CT N- tq � C c Qq A ~ m b c S O CD V a ro 11 CD eD r• ?» y p Qa �Zw CD m 7 :-�CD rD o C� o,00 O o� rrTQ ep' y d W AO H 0. 0 v A O eD 00 w to O C Q t�D 00 i i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: P:;i m7- >> :, -_ e, Job Address: -� -7 /� �� ,, E� ;jL *' 3 o r Permit Number: ❑ No one available for inspection: Time q AR P M Re -Inspection required: Yes (o When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: T11> DO NOT REMOVE THIS NOTICE ,d ° o S ivyy ►o n O O n -3 ~ g� a 3 5 N h w n n w yCnrJCb�y� xrz� C A n a� °.trr+, •e ° 00 C O � N= CIDP < < o pp O ° (D n 0���cn p> O dM. 10 O b `r zo�zo � 0 y x o H z LA �1 �ow�� ° n ° �o m G� (D ° ((D � � M ►C o� � va Froi (QQ pC�� �j H- N trJ A CD M n Q. m �� �H Eby y c ac v ►� rr I `J o°mm tr ?�� ?�� 5 w CD D ofrt C x maa o d ago �2 o� y � p n N M P. R [sJ C /� E �� -.� = 9� �tr � ° m �p w �e H—10 N O C < A C owm O A) H° U� r- rt � r z�x y� H fb r O cr w to m C3 a CD fo 5' �7 eD va m K E wrr cD eD n o NeD ° r rt, r 00 o� w C O N c d C a CD CD ,4 f fDep N r d A 00 PERMIT NO. 201800978 ty of wl�eatPijdge BUSINESS LICENSE INSPECTION INSPECTION DAY/TIME Thurs. April 19 @ 10 am INSPECTION DAY/TIME INSPECTION DAY/TIME BUSINESS NAME: Pin High Golf Specialists ADDRESS: 3760 Vance Street Suite #301 CONTACT NAME: No o name provided -300 SQ FT OCCUPANCY TYPE 3 OCCUPANCY LOAD CONSTRUCTION TYPE ❑ SPRINKLERED © NOWSPRINKLERED Inspector Signature -/q-7,qb Date i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 lnspectior� line (303) 235-2855 Office r (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 8 �� - 73 u s ss L C &,1 rze Job Address: 3 -7 & 0 1/4 it c e Permit Number: a o 1 C u R- Sec <-,f,_ -'-f- Oc c 74 pc = 73 occ 1 ve z -3 ❑ No one available for inspection: Time /0:'03 (ARPM Re -Inspection required: Yes 0 When corrections have been made, call for re -inspection at 303-234-5933 Date:-'/ - t9 • 0� Inspector: DO NOT REMOVE THIS NOTICE /0 I L) �, , r a ,, )M '� v OR 135943 .�' Roofing, Icto.� s� 525 Orlyria+ � � Saginaw, A 48601� k"A " I. T'ERTN•IS and CONDITIONS t Dura -Last, Inc,, ('"Duro-last") grants this No -Dollar Limit ("Nbt;") Warranty to the owner ("Ooiner').cif a building containing a 5 Dura -Last Roofing System ("Duro-Last System'') installed by an 'authori7ed dealer/contractor C'Contractor"), subject to the conditions �b H and limitations contained herein. a E Duro-Last's obligation during the; i st through the I Sth year shall be to repair tiny leak in the: Duro-Last System caused by any defect `c in a ccanponent of the Duro-last System or by the workmanship of the Contractor, but only as the workmanship relates to the instal' r lation of the Duro-Last System itself and not as it relates to Bather work performed, if any. Duro-Last's obligation includes, at Duro- Last's discretion, either the repair or replacement of part or all of the Dura -Last System, and also includes the furnishing or cost of labor to repair the Duren -Last System provided the following conditions are naet: is A. Duro-Last and Contractor have been paid in full for the Duro-Last System, its installation and any outstanding invoices issued # by Duro-Last that arise atter the installation; a i3. The Duro-Last System has ben approved by Duro-Least following inspection by an authorized Duro-Last Quality Assurance Representative ("Duro-Last QA Tech Rep") and this leo-Dollar Limit Warranty has been signed by a Duro-Last QATech Rep ` or Quality Assurance Manager; C. The Owner has notified Duro-Last within 7 days of the discovery of any leak, failure, or other alleged Duro-Last System i defect, Owner must notify Duro-Last by calling the Duro-Last Quality Assurance D6partanent at 1-866-284-9424, by l (� 3 e -mailing wsC dura-last.com„ or by certified mail, return receipt requested; j D.The Owner allows Duro-Last's QA Tech Rep(s), and/or Duro-Last Contractor(s) access to the roof including, if necessary, tine removal and replacement by Owner at Ow=ner's expense any and all obstructions, including but not limited to: rooftop gardens, earth, soil, pavers, decks, patio and walking surface materials, photovoltaic system, and Cather overhaarden, an T . Duro-Last ase authorizes the repair orad„ at. Duro option, either Duro-Last's QA'T"ech Rep(s),,or an authorared Contractor makes the repair. d H. LIMITATIONS and EXCLUSIONS A, This No -Dollar Limit Warranty clots not apply to a Duro Last System installed can a single-family residence, m B, Duro-Last shall not be liable for damages arising from defects in the design or construction of the building or roof assembly w i aside from the Dura -Last System, including but not limited to those defects that result in water penetrating into the building, n x° including inadequate or insufficient drainage. C. Duro-Last is not liable for any Dura -Last System defect or failure nor for subsequent damages arising from Acts of God or t � causesoutsideDuro-teat's control including, but riot limited to: _ 1) Damage caused by fire, lightning, hurricane, gale, hail„ tornado, flood, earthquake, animals, insects: or 2) Damage caused by accident, vandalism, intentional act, negligence or failure to use reasonable care, whether on the a part of the Owner or another, or a l) Damage caused by any unauthorized modification to the Duro Last System including, but notlimited to, damage ` caused by unauthorized components used in installation or repair, by additional equipment or structures added to or i( made a part of the roof, by traffic, or by chemicals not normally found in nature or the like; or � l 4) Interior condensation and/or moisture entering the .Dura -Last System through walls, copings, structural defects, MVAC t y i f systems, or any part of the building structure, including from adjacent buildings, " .a D. Duro-Last does not warrant the watertightness of metal products that are located outside of die termination of the Duro-Lase membrane. t t E. Duro-Last does not warrant against color change and/or pattern change and/or print change in the Duro-Last System, f aw Al F. This leo-Dollar Limit Warranty passes to future Owners of the building for the full 15 years hereof. t G.T"his leo-Dollar Limit Warranty must be signed by'a Duro-Least QA Tech Rep or Quality Assurance Manager. Coverage under $ �� Y' the terms of this Pio-Dollar Limit Warranty begins on the Effective Efate, "Che E fective Date is determined by Dura -Last. I� Failure of the Owner or Contractor to sign this Pio-Dollar Limit Warranty does not alter the Effective Date. �v }� H. This No -Dollar Limit Warranty shall be governed by the law=s of the State of Michigan. Duro-Last and Owner hereby agree �{ that the Circuit Court for the County of Saginaw, State of /Michigan, shall have the exclusive jurisdiction to determine any and g all disputes, or claims relating to this No -Dollar Limit Warranty and do hereby submit themselves to the sole personal ip jurisdiction of that Court. a J L. Durex -Last does not waive any rights under this No -Dollar Limit Warranty by refraining from exorcising its rights in full in one or more instances. i OVER. CONTINUED ON BACK 4 )r ti u 3 pe �• 5 3 x t" .. ti x J mat led `Vlops April 10, 2015 Molass 3760 Vance St Wheat Ridge CO 80033) Enclosed is the Duro-Last System Warranty Certificatesfor your roof at 3760 Vance St. It was inspected by a Duro-Last Inspector, The roof has received an outstanding rating on the inspection. You should keep the original warranty and send a signed copy to Duro-Last's address in the upper left corner. This will officially register your warranty. Should you ever need service on the roof, call Duro-Last directly at 1-800-248-0280, and give them your warranty number on the top right comer of the warranty certificate. Duro-Last would prefer you call them rather than us because they track warranty situations. It was a pleasure working with you on these projects. Call us when we can assist you again. Gordon Lane Account Manager Warranty Letter #I Molass 3760 Vance Street Wheat Ridge CO 80033 I hope that we exceeded your expectations during the purchasing cycle and during the installation. If you have any comments to share regarding your new roof please feel free to contact me at anytime. Please know that we will strive to continue to give you the service you expect in the future. MMEM 0 'M# Warranty Letter #1 City of Wh6atl� J� �,jOge COMMAJNiiy DEVELOPMENT JE a Building Permit Application g �14z-au; rq. i I - (please print): Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer E-mail: Phone. Electrical: FOR OFFICE USE ONLY plan1permit # �A Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanicat W.R. City License # Complete all information on BOTH sides of this form Sq. FULF :3(!) 10 Gallons Amps - Squares Other ❑ No one available for inspection: Time ♦ i CITY OF WHEAT RIDGE r f Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: fflZ Job Address: a3,�o ?a/ Permit Number: iQ/G02 ❑ No one available for inspection: Time tl; 25 C 1�C ZPM Re- Inspection required: Yes No "When corrections have been made calf for re- inspection at 303 - 2345933 Date: hg? Inspector: DO NOT REMOVE THIS NOTICE DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number Date 12486 7/18/01 Property Owner : Property Address : 3760 VANCE ST Contractor License No. : 18505 Company : BARTELS HEATING & A/C Phone : 423-7750 Phone : 422-3589 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE Description : 7 1/2 TON ROOF TOP A/C UNIT Construction Value : $2,498.00 Permit Fee : $8325 Plan Review Fee : $0.00 Use Tax : $37.47 Total: $120.72 Use: mm BUILDING DEPARTMENT USE ONLY RMi4VOR~t~,~.'~t~; SIC : Sq. Ft. : Approval : Zoning : ft.11ex., Approval : Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : 18191 Plumbing License No : Mechanical License No : Company : Southwest Electric Company : Company : Expiration Date : 4/19/02 Approval : OK/KS Expiration Date : Expiration Date : Approval : Approval : (p This permit was issued in accortlance with the provisions set forth in yopur application and is sub1ecl to the laws of the State of Colorado antl to the Zoning Regulations antl Building Cotle of Wheat Rid9e, Coloredo or any olher applicable ordinances of lhe Ciry, (2) This permil shall expire if (A) the work authorized is not commenced wrthin sixty (60) tlays from issue date or (B) the building authorized is suspended or abantloned for a period of 120 tlays. (3) If ihis permit expires, a new permit may he acquired for a fee of one-half the amount normally requiretl, provitletl no changes have been or will be made in the original plans antl specifications and any suspension or abandonment has not exceetletl one (7) year. N changes are made or if suspension or abandonment exceetls one (1) year, (ull fees shail 6e paid (or a new permit. (4) No work of any manner shail be done thal will change the natural flow ot water causing a dreinage problem. (5) Contrador shall nofify the Building Inspector Rventy-four (24) hours in advance for all inspections and shall receive written approval on inspection cartl before proceediing with successive phases of the job. (6) The issuance ot a permit or the approval ot tlrawings and specifcations shall not be construetl to be a permit for, nor an approval of, any violation of the provisions of thC6Diltlinq codBepr any other ortlinance, law, rule or regulation. Buildind,fnspector o` NHEq DEPAR'PMENT OF PLANNING AND DEVELOPMENT Building Penni( Numbcr: , q 6UILDINGINSPECTfONLINE-303-234-5'J33 Date_ CI'PY OF WHEA'P RIDGE 7500 WEST 29TH AVENUE ca o WHEAT RIDGE, CO 80215 -(3113-235-2H55) LORPO ,4Pf'LtCATit7N Property Owner: Molass Corp Property Address:3760 Vance St. Phone :303-423-7750 Convactor License No.: 18505 Company Bartels Heating & A/C Phone: 303-422-3589 OWPIEWCONTRACTORSIGNATUREOFUYDF,RSTAIYDINGANDAGRBEMEM' I hereby certify that the setback distances propased by lhis permit xpplication are accurate, and do not violate applicable ordinances, ruies or reguixtions o(ehe City o( Wheat Aidge or covenanis, euementi, or rertriaions ol recorA; that aIi meazurements shown, and allegations made are accurate; that [ have rexd and agree to abide by all wnditions prinled on this application and Lhat I assume full responsihility for compliance with the Whext Ridge Buiiding Code (U.B.C) and all oiher applicabie Wheat Ridge Ordinances, for work unAer this permit_ (OWIJF,R)(COMRACTOR): SIGiJE~ nATF / Descrip[ion: 7- a Construction Value: 2498.00 Permit Fee: 83.25 Plan Review Fee: Use Tax: 37.47 Total: 120.72 BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft: ZON7CO7MMENTS: BUI Approval: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Elecuical License No: 18191 Plumbing License No: Jviechanical License No: Company: Southwest electricalCompany: ComPan Y Eapiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This permit was iszucd in acrordancc with th< provisiom sct lonh in yow application and is subject m thc laurs of 1he SUte o( Colorado and to de Zonwng Regulations and BuilAin6 Codcs ol Whwt ftidgq Coloredo or any oNer appliobl<ordvuncu ofthe Ciry. (2) This pertnit shall ezpire i( (.4) fhe work auNonzed is mt commenced wilhin sicry (60) days fmm issuc date or (H) Ne building authorized ie suspended of abandoned for a period of 120 dayx. (3) If Lhis pertnit cxpires, n new pcrmit may be acquircd for a(e< of onc-half th< amount nonnally r<quircd, providcd no chnngcs have becn or will bc made in the onginal piw and specilica[iom and my suspertsion or abandorunrnt haz not exceeAcd one (1) year. If chanyes have been or if suspension or abandoeuneN <xcecds onc (I) ycaq lull fea shall b<paid 1'or a new pcrmit. (3) No work o1 any manner shall be done Nat will chutge the naWral Ilow of wa4r causiny a Arainag<pmblem. (s) conva«or ,h.u nooty me ouiinine inso«mr twthity-ro., (aa) noua us .dvar« ro„u ~ritPea,on, N,d .n.,u ««i,c w.iuenon ha,«roat cue bwW« pmceeding wilh suceexxive phaucs olthe job (b) lTe issuance nf a p<rmu m the appmval oi ArawinF} anA specilicntioru xhall not be ronstmed m be a pertnM1 Ior, nor an approval ol; any violation of the prrn isions of the builAing mAez nr my other orAmanca law, rule u regulaiion. ChieC Building Inspector DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 12518 BUILDING INSPECTION LINE - 303-234-5933 Date : 7/24/01 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner : Property Address : 3760 VANCE ST #301 Contractor License No. : 18505 Phone : 423-7750 Company : BARTELS HEATING & AIC Phone : 422-3589 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certiry that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of recortl; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this Wheat Codle (U.B.C.) and a all otheapplIcable Wheait R dfor ge ordln~ances ,f~or work underRhis p ermiding (OWNER)(CONTRACTOR) SIGNED DATE Description : INSTALL 7.5 TON ROOF TOP UNIT Construction Value : $5,915.00 Permit Fee : $125.25 Plan Review Fee : $0.00 Use Tax : $85.73 Total: $213.97 Use: BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : ~ Approval: Zoning : M Approval: Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : 18191 Plumbing License No : Mechanlcal ucense no : i aovo Company :Southwest Electric Company : Company : BARTELS HEATING & A/C Expiration Date : 4/19/02 Expiration Date : 10I10I01 Approval : OK/KS Expiration Date : qpproval : OKIKS Approval' (i) This permit was issued in accordance with the provisions set Forth in yopur application antl is sub1'ecl to Ue laws of the State of Coloratlo antl to the Zoning Re9ulations and Building Code ot VJheat Ridge, Coloretlo or any other appli[a01e oMinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixly (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit ezpires, a new permM1 may be acquired for a fee of one-half ihe amount normally required, provided no chan9es have been or will 6e made in e original plans and specifcaUOns and any suspension or abantlonment has not exceetled one (1) year. If changes are made or'rf suspension or abandonment ezceeds one (1) year, full fees shall be paitl for a new permit. (4) No work of any manner shall be done ihat wdl change the natural flow oF water causing a drainage problem. (5) Contractor shall no6ry the Buildin9 Inspector lwenty-four (24) hours in advance for all inspeclions antl shall receive written approval on inspection car0 before proceetliing with successive phases of the1ob . (e) ot the 6uaJdn~a code or i3pyth hePOrdinalcfea law~nr9ule or d secifications shall not be consWed to be a pemiit for, nor an approval of, any violation of ihe provisions Ch 1;<1. DEPAATMENT OF PLANNINC AND DEVELOPMENT Building Pcnnit Numbcr. 6UILDING INSPECTfON LINE - 303-234-5733 Dale~ : CITY OF WHEA'P RIDGE 75011 WEST 29TH AVENUE ~o o WHEAT RIDGE, CO 80215 -(3113-235-2H55) ~oRao APPLtCA rrON Property Owner: m010SJ Clo rP Property Address: 3760 kJa'y)0_e'~;t Phone :.505YX'775G Contractor License No.: 18505 Company: Bartels Heating & A/C Phone: 303-422-3589 O WNER/CONTRAC70R SIGNATIJAE O F UNDEASTM'DING AND AGREEMEM 1 hereby ceAify lhat the setback dislanc<s proposed by lhis permit xppiication are uwrate, and do not violate applicable ordinancu, rules or regulations oFthe City o( Wheat Ridge or covenanis, eazements or rertrictions o( record; lhat all meazurements shown, and allegalions made are acwrate, that ( have rexd and agree to abide by all wnditions printed on lhis application and ihat 1msume (ull responsibility (or compliance with Ihe Wheat Ridge Building Code (U.B.C) and nll other applicable Wheal Ridge Ordinances, for work unde`-lhis pertnit. Construction Value: -"16. oo Permit Fee: ja5.a5 Plan Review Fee: Use Tax: V' 73 TotaL a!3-`~~ (OWNERxrONT24CiOR): SIG14E~ 7Oy_~ui .h ~D !JAi'E 7/5 _C~I Description: -E~Los~ 'frn ~ rcD64~p tt'n j * BUILDING DEPARTNfENT USE ONLY SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILOING COMMENTS ApPIOVdl: PUBLIG WORKS COMMENTS: Approval: Occupancy: Walls: Roof: S[ories: Residential Units: h Electrical License No: I yJg / . Plumbing License No: Mechanical License No: /83b-5" Company:,%i,i,K u5(s~j e {ecfrtCao Company: Company,di,r-Je~S }{e~~,F ~ Al~ U Eacpiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This pennit was izmed in acmrMnce with the pmvixioM set lonh in your applicatlon and iz subject m Ihe laurs of the Slate of Colorado and to Ne Zoning Regutatiorts and Building Codu of Whwt Ridgq Colomdo or any othcr applicable ordvunces o(Nc City. (2) This pemit shall upire il (.4) ffie work awhonzed is mt commenced wiNin i rry (60) dayrs 6om issuc date or (B) the buiiding authorized is suspended or abandoned for a penod o! 120 days. (3) ff this pelmit expiru, a new pennit may be acquired (or a(ee of onehalf Ne amount nortnalty mquiad, pmvided no changu hrve been or will be made in the onginal plem anA xpeciGcauom md any suvpeW ion or abando`vnrnl hss not exeecded one (1) yuv. If<hanges have been or Ssuspemion or abando`unml exceeds one (1) year, lull fecs shal l b< peid for a new pcemit. (9) No work of :viy maruicr zhall be Aone Nat wdl chanyc th< nawral Ilow ol wamr causmg adrainage pmblem (5) Convactor shall notd'y Ne Building Irtspector twrnry-lour (24) hours In aMance for all impe<tions anA xhall recavc wnuen approval on iaspection aud bAbre pmcading wah sucrossrvc phrees of thejob (6) The ssu.ince o( a permii or ihe ippmval oi AramW anA epealirntiorts shall not be constrveG a be a pertnrt (or, mr an appmval ol, ury violaoon ol'the prnvi.cioeu ofNe builAing roAez or any oiha ordinance, law, rule ur mb latmn. Chicf Building Inspector DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 9941 BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE Date : 12/22/99 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner : Property Address : 3760 VANCE ST Phone : 423-7750 Contractor License No. : 18505 Company : BARTELS HEATING & A/C Phone : 422-3589 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $2,900.00 I hereby certify that the setback distances proposed by this permit application are accurate, P@fflllt F@2 : $83.25 and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or easements or restridions of rewrd; that all measurements shown, and allegations wvenants Plan Review Fee : $0.00 , made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building USe TaX : $43.50 Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. Total: $126.75 ED DATE (OWNER)(CONTRACTOR) SIGN Use: Description : Replace furnace BUILDING DEPARTMENT USE ONLY R~~ ~ SIC : Sq. Ft. : Approval : Zoning : ~ ~ Approval : Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Company : Plumbing License No : Company : Mechanical License No : Company : Expiration Date : Approval: Expiration Date : Approval : Expiration Date : Approval: (i) This permit was issued in accordance with ihe provisions sel (orth in yopur application and is sub'ect to the laws of the State of Coloratlo antl to the Zoning Regulations and Building Cotle of VJheaf Ridge, Colorado or any other appliwble ordinances of t~e Ciry. (2) This permit shall expire if (A) the work authonzetl is not commenced within siaty (60) tlays from issue date or (8) the builtling authorized is suspended or abandoned tor a penod of 120 days. (3) IF this permit expires, a new permd may be acquired tor a fee of one-half ihe amount normalty required, provided no changes have been or will be made in the original plans and speaFlCations and any suspension or abantlonment has not exceetletl one (7) year. If changes are matle or if suspension or abandonment exceeds one (1) year, full fees shall be paitl for a new permit. (4) No work of any manner shall be tlone tha[ will change the natural Flow otwater causing a drainage problem. (5) Contrector shall noliy the Building Inspector twenty-four (24) hours in advance for all ins0ecbons and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) The issuance of p rmit or the a proval of drawings and specifcations shall not be consirued to be a permit tor, nor an approval of, any violation of the provisions of the buil in de or a ordinance, law, mle or regulation. Chief Building Inspe r DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 ' Property Owner : MO► (153 CAP V. Dn -l 75ed C.On Property Address :$'71~G 4cia~ Ce ~t . Phone : 3`' 3 ~1z-3 •~1So Contractor License No. : jS3 3u3- Company :`3cu Fe1s Phone :~z z- 3s ,39 ~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby ceRdy that the setback dislances proDOSad by this pertnit appliwtion are accurate, and do not violate applicable ortlinancas, rules or regulations of the Ciry of Wheat Ridge or covenants, easements or rcstnctions of rewrd: tha[ all measurements shown. and allegatlans maCe are accurete; that I have read and agree to abide by a!I wndRions pnntetl on this application, antl that I assuma tull resDOnsibilky for compliance with the Wheat Ridge Building Code (U.B.C.) and all other eppliwble Wheat Ridge ordinances, for work untler this permrt. (OWNER ONTRACTO SIGNEDDATEZDIO Description : BUILDING DEPARTMENT USE ONLY , - . Approval : Zaning : Approvai : U" Approval Occupancy : Walls : Roof : Stories : Residential Units : Construction Value : 0 , q 0 ° - Permit Fee : 13 ;~7 Use Tax. :,v3 5 d Total: /,-?b, Z-s' Electncal License NoPlumbing License No Mechanical License No : Company : Company : Company : Expiration Date : Approval : Expiration Date : Approval: Expiration Date : Approval: _j Pf9ns_Rdftufred:-_] j . B18(hs Required _I A ? ~~I►4~9t1NIM (1) ThiS pertM wa8 i55uBC m acCOrCance wM1h the prov6ion5 Set fatlh in yopul appliC2bon 2ntl is Subjed to the leWS OI fltG $ta18 01 C0102tlo 2f1tl t0 U181oning ReguiaUOns antl Builtling Cotle o( Wheat Ritlge, Coloratlo or any otner aDO~i,uibie orainances ol the Ciry. (2) This permtl shall e:0ire d IA) the work authonzed is not commenceC wM1hin sixry (60) Oays hom issue Oale or l8) the bmlding aulhonzetl is suspeMeE or a0antlone0 for a pena0 of 170 Oays. (3) It tNS pemmt expiros, a new permlt may Oe acQUired /or a fee ol one-nalf the amounl nortnalry repuireE, DroviAeE no changes have Deen a will be ma0e in Ue ongmal plans antl speafirations and any suspenaion or aDanOOnmmt has not ezceedeC one (1) year. I/ changes are matle or i/ suapensron or a0aneonmem ezCeeCS one (1) yeaC lull fels shall OE paitl lor a new permit. (4) No work of any manner shall De Eone Ihat will change the naNral Ilow ol water causing a Araina9e DmGlem. (5) Contraclor shall noUry the Builtling Inspector ewenry-four (21) hours m advance lor all inspecuons an0 Shall recerve wntlen aDProval on mspection tarC be/ore prOCeeAUng with suCCesvve p0ases of the job. f61 7he rssuance ol a Dermn or the appmval ol drawings antl speufications snall not oe constmea to Oe a permn /or. nor an approval of, any viola0on o1 the provisions ol the bwltlmg cotles or any other ortlmance. iaw mie or re9uialion. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number Date 9058 6/14/99 Property Owner : Property Address : 3760 VANCE ST Contractor License No. : 20356 Company : UNITED CONSTRUCTION OF SALIDA Phone: Phone: 7195392178 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are acwrete; that I have read and a ree to abide by all conditions printed on this application, and that I assume full respopsitiN ty for, ompliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable hea Fti~l§W' ces, for work under this permit. (OWNER)(CONTRACTOR) SIGNE ✓ DATE Description : REROOF WITH TORCHDOWN PVC Construction Value : $7,000.00 Permit Fee : $13925 Plan Review Fee : $0.00 Use Tax : $105.00 Total: $244.25 Use: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company : Expiration Date : Expiration Date : Expiration Date : Approval : Approval : Approval : (1) This permi[ was issuetl in accordance with the provisions set torlh in yopur application antl is subject to the laws of the SGte of Colorado and to the Zoning Regulations and Building Code ot Wheat Ridge, Coloredo or any other applicable ortlinances of the City. (2) This permit shall expire i! (A) the work authorized is not commencetl within sirTj (60) days trom issue date or (B) the builtling authorizetl is suspended or abantlonetl for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans antl speciFlCations and any suspension or abandonment has not exceeded one (1) year. If changes are made or it suspension or abandonment exceetls one (1) year, full tees shall be paitl for a new permit. (4) No work of any manner shall be done ihat will change the natural flow of water causing a drainage proDlem. (5) Contractor shall notify ihe Building Inspector hventy-four (24) hours in advance for all inspections and shall receive written approval on inspeclion car0 before proceetliing with successive phases of the ob. (e) The issuance of a pertnit or the approval o~drawings antl specifications shall not be construetl to 6e a permit Por, nor an approval of, any violation of the provisions of the bu'tling c es any other ortlinance, law, rule or regulation. Chie Building In ector -DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 AppLICATIo N Property Owner : jVbC,4gS Co~-~ Property Address : 3"760 VIWcE 5T Phone : 3p3- Contractor License No. : Company : Phone : OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certiy that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printetl on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable t I~ e ordin~for work under this pertnit. (OWNER)(CONTR.4CTOR) SIGNE DATE~ Description : XCAool W/ 7br_v;Wv /_~o.-.j APve Construction Value. ~ / Permit Fee : Use Tax : Total : use: BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval : Zoning : ~ Approval: EMEMENEWMEEM Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiretion Date : Expiration Date : Expiration Date : Approval: Approval: Approval: (1) This permit was issued in accordance with the provisions set torth in yopur application antl is sublect to the laws at the Slate of Colora0o antl to the Zoning Regulations antl Builtling Cotle of Wheat Ridge, Colo2do or any oNer ap0liwGle ortlinances of Me Ciry. (2) This permR shall erzpire R(A) ihe work authonzetl is not commencetl within sixy (60) days from issue tlate or (B) the building authonzetl is suspentletl or abandoneA for a period of 120 tlays. (3) If this permit expires, a new permit may be acquireO for a fee o/ one-half the amount nofmally required, proviEed no changes bave been or will be maCe in the onginal plans and specifications and any suspension or abantlonment has not exceeded one (1) year. If changes arc made or if suspension or abantlonment exceeds one (1) year, full tees shall Oe paitl for a new pertnit. (4) No work of any manner shall be tlone that will change the natural Ilow ot water causing a d2inage problem. (5) Coniractor shall notiry the Builtling Inspector twenry-four (24) hours in atlvance for all inspections antl shall teceive written approval an inspection wrtl betore proceediing with successive phases of the job. (6) The issuance of a pertnit or the approval af tlrawings and specifrations shall not be mnstruetl to be a pertnit for, nor an apProval ot, any violaUOn of the provisions of the building codes or any oNer ortlinance, law, rule w regulation. Chief Building Inspector CBi Z Nw~,.... r DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 7827 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 9/23/98 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : Property Address : 3760 VANCE ST Contractor License No. : 18191 Phone : 423-7750 Company : Southwest Electric Phone : 733 3819 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $300.00 I hereby certify that the setback distances proposed by this permit application are accurate, and tlo not violateapplicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions prinled on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building , for work under this permit. Cade (U.B.CJ and all other applicable Whept Rjdge ordini (OWNER)(CONTRACTOR) Description : WIRE REPLACEMENT FURNACE Permit Fee : $25.00 Plan Review Fee : $0.00 Use Tax : $4.50 Total: $29.50 Use Electrical License No : Company : Plumbing License No : Company : Mechanical License No : Company: Expiration Date : Approval : Expiration Date : Approval : Expiration Date : Approval : (1) This permit was issued in accortlance with the provisions set forth in yopur application and is subject to the laws oFthe State o! Coloratlo and to the Zoning Requlatlons antl Building Cotle of Wheat Ridge, Coloredo or any other applicable ordinances of ihe Ciry. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the builtling authorized is suspended or abantloned for a periotl of 120 days. (3) If ihis pertnit expires, a new permit may be acquiretl for a fee of one-half Ihe amount normally required, provided no changes have been or will be made in ihe odginal plans and specifcations and any suspension or abantlonment has not exceetled one (7) year. 1f changes are made or if suspension or abandonment exceetls one (1) year, tull fees shall be paid for a new permit. (4) No work of any mannet Shall De tlone lhat will change the natural flow of water causing a drainage problem. (5) Contor shall notify the Builtling Inspector lwenty-four (24) hours in atlvance for all inspections and shall receive written apOroval on inspection cartl before Vac proceediing with succassive phases of the ~ob. (8) The issuance of a Dermit or the approval of drawings antl specifcations shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building co es or any o her ordinance, law, mle or regulation. . f~.ly Chief Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION :'EPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date 7500 WEST 29TH AVENUE ' WHEAT RIDGE, CO 80215 PropertyOwner: Rmk 1941 i6eiyAIJ Property Address : -37(oD Contractor License No.: company : ~~4ff1457' tLez~) OWNE,LCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereb,certify lhal the selback dislances proposed by this permit application are accurate, and do-.:ol violate appliwbie ordinances, rules or regulations of the Ciry of Wheat Ridge or covena~ s, easements or restridions of reeord; that all measurements shown, and allegations made are accvrate; that I have read and ayree lo abide by all conditions Drinled on this appiica:-)n, and that I assume (ull responsibifty (or compliance wAh the Wheat Ridge Building Code B.C.) and ail other appliwble ~ at Ridge o dinan for N ork under this pertnit. (OWNE 2)(CONTRACTOR) SIGNED DATE 23/ Des ;ription : "~~Y,,,pc'e 1'vlii1pe- 46;t+ Construction Value : 3vp,o0 Permit Fee : Use Tax: Total: $0.00. Use: BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approvai: Zoning : UiiBfIfT1TCbTMW2U Approvai: Approval : C cupancy : Walls Roo( : Slories : Residential Units : Electr ;al License No : Com; any : Expir~tion Date : Appn aai : (1) Thispermilwas RegulaUOns anc (2) 7TU pertnil stul aEanMOned la: I( Ihis petmil ex{ (4) No work ol any } (5) Conlroqor ihall proceeEiing wilh (6) TTei53uance of W Ihe EviWinp o Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED DY THE CHIEF BUILDING INSPECTOR AND MAYOR Plumbing License No : Company : Expiration Date : Approval : Mechanical License No : Company: Expiration Date : Approval: E In a&adance wilh the provlsions sel IoM in yoDur appiiwGOn and Is subI'ec! to the laws ol the State ol Cob20o a~W to Ne Zoninq lin9 Code of Wheal RiOgu, CObratlo w any oNer app4caDle ordinances of Ihe City. re A(A) the wotk aulhonze0 is nal commenced wiNin sizry (60) days Irom Issue Oale or (9) the builCloO auNalzed is 0uspenECd a )d of 720 days. a new pemut may be acquired (a a fee o1 one-hall the amounl normaly reQuireA, provided no changef have Eeen a will De made in the tificalions and eny suspension a abandonment has nol exceeded one (1) year. If changes aro ma0e or if suspension ot aWnOanment ,(ull ftts shall be paid lor a new pcrmit. er shall be done Ihal vrill [hanqe the naNral Ilow ol walcr rausirg a drainago pro6lem. P the Builtllnq Inspeclor twenry-lour (24) houn in advancc br an inspections 2n0 shall receivo written approval on Inspection nM Oelae essive phaxs of Ne~ob mit or Na approvel o(drawinqs and specifiralions snall not be connrued m Ee a pemul la, nor an approvalo( arry Hdatlon of Na prodsbns or any oUier or0inance. Ww, rulo or requiation. . Phone : ~4,1; ~76-U Phone : 733', ~•pyht~,,,,A~~r ~~fia 4,~'+;s~g,~ re.,,~~. DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 7801 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 9/18/98 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Properry Owner : Property Address : 3760 VANCE STREET; STE 301 Phone : 3034237750 Contractor License No. : 18505 Company : BARTELS HEATING & A/C Phone : 422-3589 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the Ciry of Wheat Ridge or wvenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) Construction Value : $8,800.00 Permit Fee : $150.50 Plan Review Fee : $0.00 Use Tax : $132.00 Total: $282.50 Use: Description : INSTALL REPLACEMENT ROOF TOP UNIT - 24,000 BUT HEATING & 10 TON COOLING BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval: Zoning : wl Approval : ee Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Company : Plumbing License No : Company : Mechanical License No : Company: Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: (1) ThiS pemiit was issued in accordance with the provisions set forth in yopur applicalion antl is subject to the laws of the State of Coloratlo antl to the Zoning Regula6ons and Building Code of Wheat Ritlge, Colorado or any other applicable ortlinances of the Ciry. (2) This permit shall expire if (A) the work authorizetl is not wmmenced within siuty (60) days trom issue Oate or (B) the builtling authorized is suspended or abantlomtl for a periotl of 120 days. (3) Itthis pertnit expires, a new permd may be acquiretl for a fee of one-half ihe amount normaily requireq provitletl no changes have been or will be made in Ihe original plans and specifcations and any suspension or abandonment has not exceeded one ('I) year. If changes are made or if suspension or abandonment exceetls one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall Oe done that will change the naturel Flow of water causing a dreinage problem. (5) Conirador shall notify the Building Inspector hventy-four (24) hours in advance for all inspections and shall receive writlen approval on inspection card before proceetlling with successive phases of Ihe job. (8) The is6uaof a p~t~o~the approval of drewings antl specifications shall not be construed to 6e a permit for, nor an approval of, any violation of the provisions of Me buil cod other ordinance, law, rule or regulation. Chief Building I`-~tSector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT Of PLANNING ANO DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 Date : CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : ryt 1~- PropertyAddress: 31100 VCLY1Ce S+• SuitC ~O~ phone: 303' `{a3 "T~SO Contractor License No. : 1$ 5 Company:l~(1r~-2tS i~2Ql:CY1C~ Qi'ld ~lL Phone:30d'~lad-35~S9 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I heroby certiy Mat Ne setbadc disbncea proposed by this permd appliwtion are aeeurete, and do nM violate applicabb oMinances, rubs or regulatlons of the City of Wheat Ridge or covenants, easements or roaMGions of record: that all meuuroments shown. and allegations made are accurate: that I have road and agroe to abide by all condkions printetl on this application. and Nat t assume lull responsibilR'y for eomphance wilh the Wheat Ridge Building Cade (U.B.C.) and all other epP~icabb Wheat Ridge ordinances, for work^der this permi[. Construction Value : ~ei8 00 ~ Permit Fee : ~60.50 Use Tax : 1 3 a t'U Total: aba 50 (OWNER)(CONTRACTOR)SIGNEO-xi "w"°-"~'=r`= Description;,I Y15fQll YYpIQCQYY)C YCY* ~f,P UYtIt - aqvlcw 6TU #~Y,f.. > >O t6~'1 Ccc~ltV • BUILDING DEPARTMENT USE ONLY APProval: V, Z Zoning: P 14 Approval : Approval : Occupancy : Walls : Roof : Stories : Residential Electrical License No : Plumbing License No : Mechanical License No : Company: Company: Company: Expiration Date : Expiration Date : Ezpiration Date : Approval : Approval : Approvai : ~ . Pfgns..tZanntced?_~,;;_~ J . PI_~C4'!SRRe9uired (t ) 7Tia permM1 was IssueE In axoMance wM lha prohsions sel lorth in yopur appliraWn and is subleet lo Ne lews of the Stffie of ColoraOO and Oo Ma Zwin9 Regula4ons and Buildinq CoCe of NRieat RiEge. ColonOO or any other appBnDle oMinances of Na Ciry. (2) 7Tis pertnrt shall exqro if (A) the vrork auNOnzetl ia not commenceC wiNin sizry (60) 4ays hom issue Oate or (B) Na bulltling auNOnzed is suspenEetl or abaaEOneE ftr a perroC ot 120 Aays. (3) If thia pefmrt axpirca. a new permit may 6e acquiretl ror a fee d one-half Me amount normairy required, proviOeE no changea nava Deen a vnll Oe mWe in Ne orqinal dans and apecifications antl any suspenawn or aDantlonment has not exceeCed one (1) year. If changes are me0e or if auspenelon or eDantlonment exteetls one (1) year. 1Nl kea shall be paitl for a new pertnR. No vrork ot arry rtWaner shell Ee Eone Ihet will Uange the neNnl flow of water wusing a Orainage Oroblem. (5) Contrector snau notdy the BuilCing Inspector menry-four (24) hours In aEVance lor ail mspecvons and shau recerve wnnen approvai on mspeMon raN be/ore proceeCiing wM successrve Ohases of the pb. (6) The issuance ot a permrt or t0e approval ol tlrewln9g and spedfcations shall not be consWea ro ba a pertnrt for. nor an approval o/. any violation ot ihe provisions of ttle bulltling coCes or any other ortlinance. law. mie or regNation. Chief Building Inspector For Mayor THIS PERMIT VALID CONLY ALL W 34 5933 24 HOURS P IOR TO~IN PIECTIION ECTOR AND MAYOR /WFI~ y~/- :D 6 4 INSPECTION TICKET JOB ADDRESS ~ 7Gd ia , ~ INSPECTION TICKET JOB l& ~ ADDRESS CO c / 9 `f 2( ~ DATE: PERMI BLDG. P T# ~RY DATE , : BLDG. PERMIT# PERMIT# /Jj PERMIT# , BLDG. CONTR. L x~'+~ C-~ 0 BLDG. CONTR. SUBCONTRACTOR ~ w~ SUBCONTRACTOR DATE INSP. REQ. \ i G~• / I DATE INSP. REQ. 7YPE OF INSP. ~ ~ ~ TYPE OF INSP. G- INSPECTION M ADE Q INSPECTION MADE REMARKS REMARKS ~ L~ ~N W.R.FORM &19 W.R. FORM 6A9 ~ N N ~ N F Y a :v Z ~ ~ a U3 :C W ° C~ m ° ~m Q ~ U' ' O ui o > t-- ~ a ~ Q N I"' W W W 2 ~ 0 Q Q 3 * O ~ ~ U a O ~ L o o~ . ~ l'7 O v ~ C E v c - W IX N A, W f- ~ a o o ' ` 0 z ~ m ~ r ~ ~ E ~o O ~ ~ Y ~ o. G N ~ > O C ~ p J L y- • ~ ~ V 3 ~ O - n> > F d > O O C } G1 6i F ~ L m . . . . . . . . . ~ 'O Q O e DEPARTMENT OF GOMMUNITY DEVELOPMENT 7500 WEST 29th AVENUE BUILDING INSPECTION DIVISION PERMIT N0. ~94~ 234-5933 P.o.BOxs38 CITY OF WHEAT RIDGE,COLO. THIS PERMIT VALID ONLY WHEN 5IGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED BELOW. _ . APPLICA710N FOR MISCELLANEOUS PEBMIL . ~ JOB ADDRESS ~ / LPiK f _Z1. / ' CONTRACTOR ASSac i Ff T2=1> oSE/e✓/CG-'S -L«-~ . ADDRESS Z/S ~3 cS0 T CT, CITY ZIPCODE aAa7 PHONE LICENSENO. / OWNER ADDRESS PHONE ZIPCODE CONTRACT PRI E $ c2OO ~ DATE S~ / Q~z 1. TVPE GrounA ❑ Woll❑ ProitttinpU 01hn 5 a D Face 2. MATERIAL 7otel Squore FNf SIGNS 1 ILLUMINATION Ya❑ No❑ typa Elsicf. Pormi1 No. 4 SET BACK FROM PROPERTY IINE N_ 5_ E_ W Zone_ Apprwed,ZOn* lnspwta (Spxify which ia front) ❑ ❑ ❑ ❑ DiaapDrovaA I. TYPE SolidE] Mon Tlwn BO% ODanO Lost Thon BO% Open FENCES ? MATERIAI NeiQM 3. SET BACK FROM PROPERTY LINE N_ S_ E_ W Zone_ Apprrnd,Zorn ImOSeta (Spepfy wMieh ii front) Q ❑ ❑ ❑ DitaDMOved OTHER Z I I. 3 DRAW SKETCH OR SHOW BELOW, THE FENCE, SIGN, OR OTHER STRUCTURE,GINhu DISTANCES FRpA PROPERTY (.INES. (SETBACNS OR VROJECTIONS INCLUDED) z ~ J ~ ~ H 2 SPECIFY NORTH ~ N STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TPADJOINING HOUSES, STREETS, ANO FROPERTY lINES;ON IRREGULAR LATS, SIIOW Lcecr DISTANCE TO PROPERTV LINES, NOT MAXIMUM OR AVERAGE DISTANCE. ,APPLICATION FOR PLUMBING, ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PEfiMIT WILL EXPIRE 180 DAYS FROM THE DATE OP ISSUANCE IF WORK IS NOT STARTED WITHIN TNAT TIME. ELECTRICAL PERMIT STATE LICENSE N0. PLUMBING PERMIT STATE LICENSE N0. MECHANICAL PERMIT AWMINUM N9RE UNDERSIZE 8 ILLEGAL fL00R BSM I5T 2N0 3RD 4TH N0. Fl1ELCirtMQr Go{011 ProporN E $dor N0. WATER LlASET FORCED AIR - BTU TEMPORARY METER WASH BOWL HOT WATER - BTU NEW SERVICE - AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONINCa-BTU LIGHTING SINK OTHER HEATING GARBAGE DISP REFRIGERATION SVSTEM POWER SU8-CIFCUITS WATER HEQTER Retri sronf Group UTILITY(RANGE,DISPO5ER,ETC) AUTO. WASMER PouMs CMr s FIXTURES DISH WASHER AUTOMAtIC SPRINKLER SYSTEM WIRING MOTORS 9 CONTROLS FLOOF2 DRAIN ELEVATOR SIGN$ URINAL TRQNSFORMERS d RECTFIERS SEWERS ADDITION TO OLD WORK OTHER M ORS OVER I HP TOTAL FIXTURES 11. C;. r 1 Asreby acknowledqe thot Ihis applico- PERMIT FEE tion i6 torrect and undentand thot I USE TAX tonnol sfmt thif prOject until thia oDDli- eation it ov0roved. I shall comvlY with TOTAL FEE $:;1 7 S!v fhe lowa oi the Slote ot Colorado and tq ~ the Zo -ReQulnlions a -9wldinq ROVE j ~V Co of the City of Wh t idQe. ny DISAPP ~ olotion of pv wiI ~ c1ouee CHIEF BUILDIN INSPECTOR,Cifyof CalRidqe imme ~~ocO~i of fp'is e.A+r~it / pI Date Issued NOT VALID UNLESS REC ,e,V d ~ (t y/'73 CALL 234-5933 24 HOURS IN ADVANCE FORINSPECTIONS DEPARTMENT OF COMMUNITY DEVELOPMENT 7500WES729thAVENUE BUIL.DING IIVSPECTION DIVISION PERMIT N0.MM941Y4380 234-5933 P.O. BOX638 CITY OF WHEAT RIDGE, COLO. THtS PERMIT VAUD ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR ANC RECEIPTED BELOW. APPLICATION FOR MISCELLANEOUS PERMIT . JOBADDRESS / i OWNER < CONTRACTOR T~L '11.( {Q~T 1 ~ ~ ADDRESS~~t'dL I~l~ ~ i ADDRESS ~ PHONE ZIPCODEOc'~~ CITY Ll`>4 ZIP CODE ~S CONTRACT PRICE $~~CJ7S~ PHON ~ - LICENSE NO. DATE 1. TV7E Ground ❑ Woll❑ ProiCCtinQ❑ O}her S w D FoCe 2. MATERIAL ^ $IGN$ 1 ILLUMINATION YaS❑ No❑ Type 4. SET BACK FROM PROPERTY LINE N_ S_ E_ W_ (specirywhicnietront) ❑ ❑ ❑ ( INSPECTION TICKET L TYPE Solid0 Mon TAOn 80% ODenD Lnt TAo ? MATERIAL JOB 5 FENCES DDRESS 1 SET BACN FROM PROPERTY LINE N_ S_ E_ W_ (Spacify whieA is tront) ❑ ❑ ❑ ~ 1. pA may 2DATE: y BLDG. PERMITA ~3&b OTHER 3. PERMITk DRAW S KETCH OFt SHOW BELOW,THE FENCE, SIGN, OR OTHERSTRUCTURE,GNiN BLDG CONTR (SETB . . ACKS OR PROJECTqNS INCLUDED) SUBCONTRACTOR DATE INSP. REQ. ~4 - 'A -9 ~ TYPE OF INSR INSPECTION MADE O" STREET REMARKS SHOW DISTANCES FROM THE MAIN BUILDING T6ADJOINING HOUSES, STREETS, ANI W.R. FORM 619 DISTANCE TO PROPERTV IINES, NOT MA%IMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAI THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK 0 PERMIT WILL EXPIRE 180 DAVS FROM THE DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN THAT TIME. ELECTRICAL PERMIT STATE LICENSE N0. PLUMBING PERMIT STATE UCENSE N0. MECHANICAL PERMIT 11LUMINUM WIRE UNDER SIZE 8 ILIEGAI FLOOR BSM IST 2ND 3RD 4TM NQ FLE4CicNQr Ga{ql E Sdor N0. WATER ClASET FORCEO AIR - BTU TEMPORARY METER WASH BOWL HOT WATER - BTU NEW SERVICE ° AMPS BATH TUB STEAM - 8TU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTING SINK OTHER HEATING GARBAGE DISP REFRIGERATpN VSTEM POWER SUB-GFCUITS WATER HEATER Rafri eront 6rou UTIUTY(RAN6E,DISPO5ER,ETC.) AUTO. WASHER PpuMt CMr e FIXTURES DISH WASHER AUTOMATIC SPRINKLER SYSTEM WIRING MOTORS 9 CONTROlS FLOOR DRAIN ELEVATOR $IGNS URINAL TRANSFORMERS 6 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES I hereby ocknowledpe that this aDDlica- tion n eonecf and undeistond ihat I eonnof start this project until thia appli- totion is o00roved. I shall comply with tAa lowe of 1he Stote ol Colorodo ond to ths ZOninp Requlotiona ond Buildinq icant. namn PERMIT FEE ~ O Code oithe City oi Wheai Ridqe. Any vi0lation of the obove terma will couee immediate rev cotion of this permif USE TAX TOTAL FEE $ ~Q CHIEF BUILDW6`WSPECTOR,Cityof Date Issued ~g iT lID UNlE55 iIECEi i If(0//3 S` mn L ltQ h Vy CALI 234-5933 24 HOURS IN ADVANCE FOR INSPECTIONS