Loading...
HomeMy WebLinkAbout3090 Reed Streetb City of Wheat Ridge Residential Mechanic PERMIT - 201801510 PERMIT NO: 201801510 ISSUED: 05/24/2018 JOB ADDRESS: 3090 Reed ST EXPIRES: 05/24/2019 JOB DESCRIPTION: Replacement of gas furnace 65 BTU's. 80% efficiency. *** CONTACTS *** OWNER (303)881-5751 WOODWORK REALTY -JEFF SUB (303)659-3400 George Donaldson 180142 Home Service Heroes Inc *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / EARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,950.00 FEES Furnace Replacement 40.00 Total Valuation 0.00 Use Tax 61.95 ** TOTAL ** 101.95 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2012 IRC & 2014 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I, by my signature, do hereby attest that the work to be per shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be per is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanyingplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall n t roceed or conceal work without written approval of such work from the Building and Inspection Services Divisio 6. The issnce r grant* of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applica, or a or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Residential Mechanic PERMIT - 201801510 PERMIT NO: 201801510 ISSUED: 05/24/2018 JOB ADDRESS: 3090 Reed ST EXPIRES: 05/24/2019 JOB DESCRIPTION: Replacement of furnace 65 BTU&#39;s. *** CONTACTS *** OWNER (303)881-5751 WOODWORK REALTY -JEFF SUB (303)659-3400 George Donaldson 180142 Home Service Heroes Inc *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,950.00 FEES Furnace Replacement 40.00 Total Valuation 0.00 Use Tax 61.95 ** TOTAL ** 101.95 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2012 IRC & 2014 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the roperty and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. I further attesrthat I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle ones Date I . This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3, If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The antinglof a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applic 1 od or any nance or regulation of this jurisdiction. Approval of work is subject to fyeld inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of KCOMMUNii-y WhcatId�gc DEVELOPMEN-, Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a_ci.wheatridge.co.us I FOR OFFICE USE ONLY I Date:: / /1 q1 L Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: U Property Owner (please print): Phone: 30391 Property Owner Email: Tenant (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Ar1r1rPSG City, State, Zip: Arch itect/Engineer• ArchitectlEngineer E-mail: Contractor: City of Wheat Ridge License #: Phone: - ,-A- a Phone: 363 4 Sy -3 IC -d Contractor E-mail Address:— Cdw% For Plan Review Questions & Comments (please print): CONTACT NAME (please print): OAifl Cc% nol As Phone: 3ck3- 6,SY 3V(I D CONTACT EMA{L(please print): Sub Contractors (Must provide Wheat Ridge License No.): Electrical: Plumbing: W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub. City License # City License # Mechanical: W.R. City License # COMMERCIAL )(RESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. �-4aee-Lne-n+ of iuCv�GCfi Commercial Projects Only: Occupancy Type: Sq. Ft./LF Amps BTUs Squares �S 61'A Construction Type: Gallons Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ Q eEr�'U-J, OWNER/CONTRACTOR SIGNATURE Or UNDERSTANDING :AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of' the City o'f Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are acCUrate, that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City ol'Wheat Ridge codes and ordinances for work under any permit issued based on this application; that T am the legal owner or have been authorized by the legal owner of the properly to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. . CIRCLE ONE: (OWNER) Signature (first and last name): Printed Name: ZONING COMMMENTS: Reviewer. BUILDING DEPARTMENT COMMENTS: Reviewer. PUBLIC WORKS COMMENTS: Reviewer. or ((ti UTHORgED REPRESENTA DEPARTMENT USE ONLY of (OWNER) (CONTRACTOR) DATE: S �� 3 —1 Sf OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: M A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: I-! 0 9 - 5= ,h 11 ) Job Address: 3 0 g c fi e- c1 S34 Permit Number: a O ) 7 O ) -71; & ❑ No one available for inspection: Time f 6i�)PM Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: S-11 S Inspector: —1`t DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L/ o q - F-7,'r1g ) Job Address: '� r) q c (;c P, j S + Permit Number: —)0 1-7 0 I -7 R /, 1 nQ) 11✓a r �� cti I S &c v re d 4-V r o Jr. . Y � � / I ltd I o tzQZ Il e 1:5.4 ❑ No one available for inspection: Time 3 @RM Re -Inspection required: es No When corrections have been made, call for re -inspection at 303 -234 - Date: -S- 03 -234 - Date: S Inspector: —T" T� DO NOT REMOVE THIS NOTICE ( CITY OF WHEAT RIDGE _:�9rBuilding Inspection`Df'ision (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: y C - P, ")a I Job Address: -3090 1'Sn e �✓ '- Permit Number: a 0 i-7 0► -1 g (o A 1 /a U �,4 t" ar art f re S C k v e w n r,e a C4,/ ❑ No one available for inspection: Time q ; 4 / qPM Re -Inspection required: Ces No When corrections have been made, call for re -inspection at 303-234-5933 Date: s- a Inspector: --T-b DO NOT REMOVE THIS NOTICE ❑ No one available for inspectioq,:-Tilne ►6.��AM/I., Re -Inspection required: Yes Nom J When corrections have been made, call for re -inspection at 303-234-5933 Date: /F Inspector: DO NOT REMOVE THIS NOTICE 7/1.Gyi-57All i CITY OF WHEAT RIDGE Building Inspection Division°I`a �=F� (303) 234-5933 Inspection line 235-2855 Office • P , (303) (303) 237-8929 Fax / ! INSPECTION NOTICE Inspection Type: Job Address: 3G'gG 7— Permit Number: ❑ No one available for inspectioq,:-Tilne ►6.��AM/I., Re -Inspection required: Yes Nom J When corrections have been made, call for re -inspection at 303-234-5933 Date: /F Inspector: DO NOT REMOVE THIS NOTICE Kimberly Cook From: Sterling Dyer <sterling@sterlingsteele.net> Sent: Friday, April 20, 2018 2:20 PM To: Kimberly Cook Subject: RE: 3090 Reed St. Wheat Ridge CO Permit Sterling Steele will be the new GC on the permit for 3090 Reed St., Wheat Ridge, CO 80033. Please put Sterling Steele's license number on permit: License Number: LIC240767 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax Inspection Type: INSPECTION NOTICE 23r - -)C Job Address: 109 0 IZ(f-F-,� � , Permit Number: /ZQ l-- o -72-q<, ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes 60) When corrections have been made, call for re -inspection at 303-234-5933 Date: ZLl Inspector: DO NOT REMOVE THIS NOTICE (C °= 0 = CL (p ' SD 3 ; 0(D W = 0 = C:) 000 0 5✓ y� L N i ■ �. n ni > ° D o ma° o a W C3 m cwn \� OD W 03 to C3 _ m COC d o cmi m .pp m 3 3 •p p C► CL �; a m m D y ,O C 1 / fv- Cn UJ a' , j ED m Q In y j EO m n W I Z f1J OD (�_ 0 svN W •�� 1 i W A g� N O a7 f i Ln ID �� N O w N I< 3 o m w f1J o w �� 03 su C CD y d b � coCID o CA= WSD m C3 C3 ED ❑0000 0EgP F" III z��a¢� M N CD (n (A1 �% L1J con °- a m m m m Z -< Q tj W ���>>nn��� mm m m O_ _:-__-•l P' Al D O w s_�i »' w -I m c t 7D tD � cr N ru 13L w CL CD ,i' r. .. < N :) u� d m n O aCDd Q m Qo fil e v a n� s: t•- :"•y o v 3 3 El 11 T� 0O11 o m m' -4 w 'N A zlom Km m M A 3 rx n .wws�wrn •v FS.; " m aw m -CLW, El 11 m ❑ ❑ o o m w o a 10 CID0w w o �; y �' CD a rt City of Wheat Midge �CCDEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 291h Ave. February 22, 2018 Woodwork Real Estate, LLC Mr. Jeff Wood 3090 Reed Street Wheat Ridge, CO 80033 Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 RE: 201708456 Single Family Dwelling Interior Remodel at 3090 Reed Street Dear Mr. Wood, I am writing this letter to inform you that your General Contractor Derek Thiess, of The Mystinfield Group, LLC, has recused himself from the above permit as the General Contractor. As a result, your project officially does not have a General Contractor listed on the permit, and we are therefore suspending all work and all inspections on your project until you are able to obtain a new General Contractor and add him/her to the permit. Consequently, we will be posting the project site with a Stop Work Order until a new General Contractor is listed on your permit. To continue working and before we can let work resume under this permit please select a new General Contractor and have him/her or his/her representative come to the Building Division Counter below and add their company to the permit. Your new General Contractor needs to provide insurance information and be licensed in the City of Wheat Ridge. Should you have any questions regarding this matter please feel free to give me a call. Respectfully, Kenneth Johnstone Interim Building Official and Community Development Director 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2844 Fax: 303-237-8929 www.ci.wheatrid eg co.us City Of W heat l dge COMMUNITY DEVELOPMENT » w-*-,'.ci.wheatridge.co.us i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: "300 Permit Number: -:;>v17cUq ❑ No one available for inspection: Time .� ��� AU0MM) Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: % Inspector: DO NOT REMOVE THIS NOTICE INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspectio.1 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspectiou before MIDNIGHT (11:59 PM) to receive n insp cti n the following business PERMIT: ZADDRESS: ' y `' JOB CODE: /] Foundation Inspections Date Inspector Initials 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbi;;g Underground Ext. 206 Water Underaround Date I Inspector Initials Comments Comments Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections SEE OVER FOR ADDITIONAL INSPECTIONS PERMIT (C (J ADDRESS: (.' JOB CODE: In Comments Rough Inspection (continued) Date Initials 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Gradi 323 Miscellaneous Final Inspections Date 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Root 410 Final Window/Door 411 Landscape/Park/Planning* 412 Row/Drainage/Public Works** ood plain Inspection** re Insp. / Fire Protection*** ublic Works Final** r416 orm Water Mgmt.** 1417 Zoning Final Inspection* 418 Building Final Inspection InspectorI Comments Initials Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 '*For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE L Inspection Type: 411113 Job Address: 06)0 R.. -St Permit Number: �;)Ui 70 F- 156 t r h (z_, Al ty /�) �%J �t. 1 l_ r) 61 ❑ No one available for inspection: Time AM/P� � rRe-inspection required: Yes; No 7*7 *When corrections have been made, call forre-inspectionat 303-234-5933 Date:-/-/' ` P' 1 Inspector: 3J 1" (7l 1 r — DO NOT REMOVE THIS NOTICE City of Wheat Ridge x r Residential Remodel PERMIT - 201708456 PERMIT NO: 201708456 ISSUED: 12/01/2017 JOB ADDRESS: 3090 Reed ST EXPIRES: 12/01/2018 JOB DESCRIPTION: Remove load bearing wall to create Master Suit and Bathroom; basement remodel; add 2 egress windows in downstairs bedroom; asbestos abatement in upstairs bathroom; 1,100 sq ft *** CONTACTS *** OWNER (303)618-5358 WOODWORK REALTY -JEFF GC (720)421-8174 Derek Thiess 120023 The Mystinfield Group, LLC SUB (303)909-7355 Robert Joseph Magee 110130 Grateful Electric SUB (720)275-8725 Richard Collins 100264 United Plumbing Services Co. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 40,000.00 FEES Total Valuation 0.00 Plan Review Fee 399.46 Use Tax 840.00 Permit Fee 614.55 Investigative Fees 614.55 ** TOTAL ** 2,468.56 *** COMMENTS *** *** CONDITIONS *** **PERMIT FEES DOUBLED FOR STOP WORK ORDER** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. Basement is NOT APPROVED AS AN INDEPENDENT DWELLING UNIT. **Certificate of Completion will not be issued until Public Works requirements are met for drainage** PERMIT NO: JOB ADDRESS: JOB DESCRIPTION City of Wheat Ridge Residential Remodel PERMIT - 201708456 201708456 3090 Reed ST ISSUED: 12/01/2017 EXPIRES: 12/01/2018 Remove load bearing wall to create Master Suit and Bathroom; basement remodel; add 2 egress windows in downstairs bedroom; asbestos abatement in upstairs bathroom; 1,100 sq ft I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I am ally authorized to include all entities named within this document as parties to the work to be P e d that all to b ormed is disclosed in this document and/or i 'accompanying approved plans and specifications. 12_4-)1-�;1- ire of OWNtR r6r ONTRACTOR, (Circle one) 6 Date / This permit was issued ed on .anon provided in the permit application and accompanying plans and specifications and is subject to the compliance wit those documents, and all applicable statutes, ordinances, regulations, policies and procedures. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the original permit fee. If this permit expires, a new pen -nit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. The issuance or granting of a permit s , 11 not by c nstrued to be a permit for, or an approval of, any violation of any provision of any applicable code or g i%e or r ti f is jurisdiction. Approval of work is subject to Field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of �Wheatidge COMMUNmy DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits .ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # jom Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Zf,:,�f,O� . ti Owner Property Owner Email: Mailing Address: (if different than property address) Address , State, Zip: W Arch itect/Enaineer: Architect/Engineer E-mail: Contractor: Contractors City License #: Contractor E-mail Address: Qj Phone: P 2-LX_117 Phone: 7--41-0 �( � :: 5 r/ )' i Sub Contractors: Zee,,, W { ,,, /�, a / � ( Electrical) ��tL;l+l� Plumbing:l�n�t �Z-L IVlechanical: W.R. City License # W.R. City License # W.R. CitY License # Other City Licensed Sub: City License # Other City Licensed Sub: City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and mmnunt of mntPrialc to ha imp.rl Ptr. ) Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNE�� TRACTOR) or (RUTH ZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): DATE: t P71 // -,-`DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION! Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ ❑ COMMERCIAL D( RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE 9 ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION 9 WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ® PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) IfF%�Ni Curt Sti?srr wailOPs7,4,rs AOD�S � d; �✓ s a Cc,� e3 de<ISly; N g le 7v (3e�rE'cc�.rt � r 7e /Y7 A S 7,e- r •�., m� S-7c�.o- S fri r Sq. Ft./LF ! / ey Btu's Gallons Amps Squares Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) D, 00 o OWNERWONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER (CONTRACTOR) (ArTHORIZEDTWESENTATIVE) of (OWNER) (CONTRACTOR) Electronic Signature (first and last name): /,-f / / /,,x'/1/1' 7 DATE: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ D1t' dons • Submit two complete sets of required information.'' • Draw a floor plan with dimensions drawn to scale, showing the layout of the entire basement. Label the use for all of the rooms.' L• Show electrical outlets, smoke Vis, carbon monoxide alarms, lighting, tans, plumbing modifications, cleanouts, furnace,and water heater. List window sizes and types, identify emergency escape and rescue- -- windows, and egress window wells with ladder and clear dimensions of • window well. Basement Hnish ReQ*ements it the finished ceiling will be less than T, please consult your Building Department. 2. 810M trey WNW. Ali basements and sleeping rooms must have an emergency escape window or exterior door, Emergency escape windows with a sill height below grade must be provided with an emergency escape window well and ladder. (For emergency escape window and window well requirements, see page 3.) s. Vnicke Ate: Smoke alarms are required in all basements. if the finished basement contains a sleeping room, a smoke alarm must be installed on the ceiling or wall in the sleeping room and in the hallway or area t immediately outside of the sleeping room. Smoke alarms added to satisfy the above requirements must be hard -wired with battery backup, and interconnected with existing smoke alarms. Smoke alarms are required to be hardwired and interconnected in new and existing bedrooms, halls and on each level unless removal of interior wall or ceiling finishes would be required, In this case, battery operated devices are acceptable. Listed wireless alarms are acceptable. 4. Carter! MonoWe AM=: Carbon Monoxide alarms are required on each floor with bedrooms. They are recommended to be located no farther than 15 ft, from any bedroom entrance. Do not install within 15 fl, of a fuel burning appliances. Follow manufacture's recommendations for lavation testing and replacement. 5 FW &Mft AMORMIS: urnaces and water heaters cannot be located in a bedroom or bathroom unless appliances are installed in a dedicated enclosure in which all combustion air is taken directly from outdoors, and a weather stripped solid door equipped with an approved self closing device is installed, if the furnace and water heater are being enclosed, adequate combustion air must be provided for these appliances to operate properly. For maintenance purposes, a minimum of 30 inches clear working space must be provided in front of furnaces and water heaters. Maintenance or removal of each appliance must be possible without removing the other or disturbing wails, piping, valves, ducts, vents, wiring or junction boxes. This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. ft is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. 9/9113 identity modifications to the existing structure such as posts, beams and floor joists. Indicate height of dropped ceiling areas less than 7 feet. A shower or tub equipped with a showerhead shall have a minimum ceiling height of 6'8" above a minimum area 30" by 30" at the showerhead. See Exception 2, P2708.1. Show plumbing fixtures and clearances around each. Show Insulation values & Floated Waft In areas subject to floor heaving, non-bearing walls on basement floor slabs should be built to accommodate not less than 1-112 inches of floor movement. A detail of a typical floated wall is included on Page 3 of this hand-out. 7. P44610dft F reblocking must be installed in concealed spaces of wood -furred watts at the ceiling level, at 10 -foot intervals along the length of the wait and at all interconnections of concealed vertical and horizontal spaces such as intersection of stud walls and soffits or dropped ceilings. A detail of typical fireblocking is included on the following page of this handout. Fireblocks may be constructed of 1-112 inch lumber, 3/4 inch plywood, OSB or particle board, 112 inch gypsum board or fiberglass insulation 16 inches minimum in height, securely fastened. Check with your Building Department for insulation requirements. 8. Mme WRIM Bugs: It access to the area or space under the basement stairs is provided for storage or other uses, the walls and ceiling of this enclosed space must be protected on the inside withl/2 inch gypsum board. 10. Batltro m: Toilets must be provided with a minimum of 21 inches in front of the toilet and 15 inches from the center of the toilet and any sidewall or other obstruction. Showers shall have a minimum inside dimension of 900 square inches, capable of encompassing a 30 inch circle and be finished 72 inches above the floor with non-absorbent materials. Shower door minimum clear opening width is 22 inches. See Exception 2, P2708.1. A ventilation fan is required in toilet rooms and bathrooms with unopenabie windows. The fan must be vented to the exterior of the building and not to terminate within 3 feet of an opening. 11. Lo" i V list: Lighting and ventilation are required for any finished portion of the basement. Contact your Building Department for specific requirements. The BWkW4 Depwvmn aW can kelp you dsWqnM MR k 1111miss 'y t0 MWt MUMM sally relldf'l "O. 9/9/13 2x4 or 16" batt insulation securely fastened Floor joist Typical soffit — Finish material Fireblock here or here or here Hint: Install fire stop before installing wall Fireblock here or here Fireblock concealed spares of furred walls and soffits at 10 foot intervals along the length of the wall with 2x4 lumber, plywood or gypsum board nailed to wall stud and held tight to concrete foundation wall from floor to ceiling. FII remaining gaps at top and bottom with mineral wool or fiberglass insulation. New 2x4 perimeter wall New 2x4 interior partition Existing concrete foundation wall Wali finish material _ 40d nails every 24 inches through bottom plate into floor plate. Pre -drift holes in bottom plate for 40d nails Minimum 1 1/2 inch void space Pressure treated 2x4 floor plate anchored to floor slab Spacer —same thickness as wall finish materia! ; Basement floor slab Emergency Escape And Rescue window wells must provide a minimum area of 9 square feet with a minimum dimension of 36 inches and shall enable the window to open fully. If the depth of the window well exceeds 44 inches, a permanently affixed ladder must be provided. The ladder must not interfere with the operation of the window. Window well Net clear dimensions when fully opened to provide 9 square feet of opening. Ladder or stair Emergency 36^ escape or7,17minrescue opening with finished sill-- _� height below Ladder or stair permitted to the adjacent encroach a maximum of 6 inches into the required dimensions. This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. it is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. Emergency Escape And Rescue Windows must meet the following criteria: A minimum total openable area of not less than 5.7 square feet A minimum clear openable height of not tens than 24 inches A minimum clear openable width of not less than 20 inches. A finished sill height of not more than 44 inches above the floor and the window should be operable from the inside with normal operation and without the use of tools, keys or special knowledge. Examples of Complying Height & Width Combinations 34 rte`— clear �."_..j Openable area=5.7 24' sq.. clear Minimum size window for 24° clear height 44" max. Operate 41" area --6.7 :fear sq.ft. Floor Minimum size window for 20" clear width 9/9/13 Colorado Chapter of the International Code Council Now to Use Ift ON Provide two sets of plans, drawn to scale and complete the following (hint- use graph paper with 114' squares. Example: 1/4" = 1'). Check with your jurisdiction for additional requirements. 1. RO*W US BUNININI GOO 2. PP0VM8 2 How Plus S, RA out a Ming Permit AppIcatiu The majority of permit applications are processed with little delay. The submitted documents will help determine if the project is in compliance with building safety codes, zoning ordinances and other applicable laws. Smoke alarms and carbon monoxide alarms are required. The Colorado Chapter of the International Code Council is a professional organization seeking to promote the public health, safety and welfare to building construction. We appreciate your feedback and suggestions. To obtain a master copy of this building guide, please write to the Colorado Chapter of the International Code Council, P.O. Box 961, Arvada, CO 80001. http:Uwww.00loradochapteriec.org Z�z3s 2x3` ® o s3 Gtcj ��ryit LL.P- N yit► =p FAnntLy RaaM � c• �• -�.r--- _�� - ' X. e u1 r � X3'10 Co pgrECToR v r Gcoas GFt. s UN FIN IS 14 ED Swct AILARM ,IN Fes' LFj I f $4'fl ROaM CD This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. A5"-1I's 644& " 9- &,.-- Q,,NS ► N S Re I e ASL.. r W I N acs ma c FC-t 'SOALL CWAV U'l 1J V�*l NNrt: 'Fb Ur Wi W (-x City of eft commuNrrY DEwLOPt+�ENT City of Wheat Ridge Municipal Building 7500 W. 291s Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 All work is subject to Field Inspection and must comply with the 2012 IRC,2012 IPC, 2012 IMC and the 2014 NEC 3 Burial depth requirements: Electrical - direct burial conductors shall be a minimum of 24 -inches deep, non-metallic conduit 18 -inches deep or 24 -inches under driveways. (IRC Table E3803.1) Water Lines - shall be a minimum of 36 -inches deep. (IRC P2603.6) Gas Service Piping - installed a minimum of 12 -inches below grade or 8 -inches below grade where serving individual outside appliances. An 18 AWG yellow insulated tracer wire must be installed adjacent to underground nonmetallic gas piping and terminate above grade at each end. (IRC G2415.1.2 and G2415.17.3) �, Underground plumbing pipe shall have a solid and continuous load-bearing support. Piping cannot bear on rocks. Pipes passing under a footing or through foundation wall shall be provided with a relieving arch or a sleeve. Trenches parallel to footing shall not extend below the 45° plane of the edge of the footing. Water piping must be buried a minimum 36 -inches deep. Water service pipe may be installed in the same trench as the building sewer provided the sewer pipe material is listed for underground use within the building or the water service pipe is separated from the sewer by a minimum distance of 5 -feet horizontally or elevated at least 12 - inches above and to one side of the sewer line. Frost depth to the bottom of the foundation footings must be as noted on the engineered plans. If not noted, the frost depth to the bottom of the footings must be a minimum of 36 -inches below finished grade. (IRC TableR301.2.1) 6 Caisson and helical pier foundations will not be inspected by the city of Wheatridge. A qualified, Colorado - licensed engineer must perform the placement, drilling, and reinforcement of drilled piers. A signed, sealed and dated inspection report must be provided to Building Inspection Services prior to the rough inspections. (R 110.5.2.3) I A perimeter drain system that discharges to an approved drainage system is required around all foundations that enclose usable spaces below grade. Foundations that retain earth and enclose interior spaces below grade must be darnp proofed. (IRC R405. 1,R401.2.14) 8 Slabs below grade must maintain a minimum of 6 -inches above the design water table. The interior finished crawl space grade must be a minimum of 36 -inches above the design water table. (R401.2.1.3and R401.2.1.5) 9 Garage floor surfaces must be approved noncombustible materials. Floors must be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway. (IRC R309.1) 10 Foundation plates and sills must be bolted to the foundation wall as prescribed on the engineered plans. If not noted, bolts shall have a minimum diameter of %2 -inch, embedded at least 7 -inches and spaced not more than 6 -feet apart. A minimum of 2 bolts are required per plate section, with one bolt located within 12 -inches of each end of each plate. (IRC 8403.1.6) vi%w.cn.wheatrldge.cce.0 s Rough Framing and Wood Requirements i i The complete rough inspection is to be made after the rough framing, rough electric, rough plumbing, and rough heat and ventilation are complete. The building should be fully enclosed with the roof covering and siding in place. o Protection from decay shall be provided in the following locations by the use of naturally durable wood or wood that is preservative treated in accordance with AWPA U 1: (IRC R317) A. Wood joists closer than 18 -inches and wood girders closer than 12 -inches to grade located within foundation periphery. B. Wood framing members that rest on concrete or masonry foundation walls and are less than 8 -inches from the exposed ground. C. Sills and sleepers on a concrete or masonry slab that is in direct contact with the ground. D. Wood girders entering concrete or masonry walls with a clearance less than %2 -inch. E. Wood siding, sheathing, and wall framing less than 6 -inches above the ground. F. Wood members supporting moisture -permeable floors or roofs that are exposed to the weather. G. Wood finning strips or wood members attached directly to the interior of below grade exterior masonry or concrete walls. H. Wood in contact with the ground, embedded in concrete in direct contact with the ground or embedded in concrete exposed to the weather that supports permanent structures intended for human occupancy shall be approved pressure -preservative -treated wood. ;Accessible under -floor areas shall be provided with a minimum 18 -inches x 24 -inches opening through the floor or 16 -inches x 24 -inches opening through the perimeter wall. When the access is through a below -grade wall an areaway of not less than 16 -inches x 24 -inches must be provided. Where equipment is located beneath the floor, the access opening must be within 20 -feet of the equipment and allow the removal of the largest piece of equipment. (IRC R408.4 and M 1305.1.4) Basements greater than 200 square feet and every sleeping room shall have at least one operable emergency and rescue opening or a door to the exterior. Emergency escape and rescue openings shall meet the following requirements: A minimum clear width of 20 -inches, a minimum clear height of 24 -inches, with a total net clear opening of 5 square feet for grade level windows and 5.7 square feet for all others. A sill height of not more than 44 inches pleasured from the finished floor to the bottom of the clear opening. Window wells for emergency escape and rescue shall provide a minimum net area of 9 square feet with minimum horizontal projection and width of 36 -Inches. The area of the widow well shall allow the emergency escape and rescue opening to fully open. (IRC R310) Columns must be restrained to prevent lateral displacement at the bottom end to insure against uplift. (IRC R301.2.1, R407.3) i 1 Fire blocking shall be installed to cut off all concealed draft openings in the following locations: (IRC 302.11) A. In concealed spaces of stud walls and partitions, including furred spaces, vertically at the ceiling and floor levels, and at 10 -feet horizontal intervals. 13. At interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings, and cove ceilings. In openings around vents, pipes, ducts, cable, wires, chimneys, fireplaces, and similar openings that afford a passage for fire at ceiling and floor levels. 1). In concealed spaces between stair stringers at the top and bottom of the run, and between studs in line with the run of the stairs at unfinished walls. i �1 At least one egress door shall be provided for each dwelling unit. The egress door shall be side -hinged, and shall provide a minimum clear width of 32 -inches. Egress doors shall be readily openable from inside the dwelling without the use of a key or special knowledge or effort. (IRC R311, 8311.2) i. 9 Where shall be a floor or landing on each side of each exterior door, The landing must be no lower than 73/ - inches below the top of the threshold of the door provided the door does not swing over the landing. (IRC 8311.3) G Handrails shall be provided on at least one side of stairways with 4 or more risers and ramps with a slope exceeding 1:12. Handrails shall be mounted 34 -inches to 38 -inches above the nosing of the treads. Handrails must be continuous for the entire length of the stairs and provided with a minimum space of 1'/2 -inch between the wall and the handrail. Ends shall be returned or terminate in newel posts or safety terminals. See the requirements and more information. (IRC 8311.7.8) 21 Handrail Grip Size Shall Be: A. Circular Handrails: 1'/ -inch to 2 -inches perimeter. B. Non -Circular: 4 -inches to 6% -inches perimeter with a maximum cross section of 2% -inches. U Perimeter Dimension Greater than 6'/ -inches: shall have a finger recess on both sides. 22 Guards must be provided for porches, screened porches, balconies, fixed seating and raised floor surfaces more than 30 -inches above the floor or grade below. Guards must have a minimum height of 36 -inches. Open sides of stairs with a total rise of more than 30 -inches above the floor or grade below shall have guards not less than 34 -inches high. Intermediate rails shall not allow the passage of a 4 -inch sphere. (R312)Window fall protection must be provided for window openings less than 24 inches above the finished floor and more than 72 inches above grade or surface below. (R312.2) 23 Ceiling heights for habitable rooms, hallways, bathrooms, toilet rooms, laundry rooms, and basements shall be a minimum of 7 -feet measured from the finished floor to the lowest ojection of the ceiling. Non -habitable basements may have a ceiling height of 6 -feet, 8 -inches with clearance below beams and ducts of 6 -feet, fl- inches. Bathroom may have a ceiling height of 6 -feet, 8 -inches at the fixture front clearance area and over the fixture. (IRC R305.1) 24 Attic access must be provided for attics that exceed 30 square feet and that have a vertical height of 30 -inches or greater. The access must be located in a hall or readily accessible location with a minimum 22 -inches x 30 - inches access opening. The access must provide a minimum of 30 -inches headroom. (IRC 8807) 2 Enclosed attic and rafter spaces must have cross ventilation for each space through screened openings. The total net free ventilating area shall not be less than 1 to 150 of the area of the space ventilated. The area may be reduced to 1 to 300 if 50-80% is provided by ventilators located in the upper portion of the space or if a vapor barrier not exceeding 1 perm is installed on the warm side of the ceiling. At least a 1 -inch space is required between the roof sheathing and the insulation at the location of the vent. (IRC 8806) 26 Rafters must be framed to a minimum 1 -inch nominal ridge board that is not less than the depth of the cut end of the rafter or to each other using a gusset plate. Hip, and valley rafters shall be a minimum of 2 -inches and not less in depth than the cut end of the rafter. Hip and valley rafter shall be supported at the ridge by a brace to a bearing partition or be designed. (IRC R802.3) 7 Rafters and ceiling joists having a depth -to -thickness ratio exceeding 5:1 shall be provided with lateral support at points of bearing to prevent rotation. Rafters and ceiling joists having a depth -to -thickness ration exceeding 6:1 shall be supported laterally by solid blocking, diagonal bridging or a continuous 1 -inch by 3 -inch wood strip nailed across the rafters. (IRC R802.8) Roof trusses or rafters must be attached to supporting walls with approved hurricane clips. Trusses must be braced to prevent rotation and to provide lateral stability in accordance with the construction documents and the individual truss design drawings. (IRC 8502.11.2, 8802.11) a' Trusses must be designed and fabricated in accordance with ANSI/TPI 1. A licensed professional shall prepare the truss design. Trusses must be legibly marked within 2 -feet of the center to identify the manufacturer, the design load, and the spacing. Truss engineering and layout must be provided at the site at the rough framing inspection. (IRC 8502.11 and R802.10) r Roofing material Wood roofs in the plain areas are limited to minimum Class "B" roof coverings. Shingle installation shall meet the manufacturer's high -wind installation procedures in areas where wind load is greater than 105 mph (V3S). Chapter 9, R301.2.1, R325, and manufacturer's listing All habitable rooms shall be provided with aggregate glazing area for natural light of not less than g% of the floor area of such rooms. The glazed areas need not be installed in rooms where section M1507 is satisfied and artificial light is provided at an average of 6 foot candles at a height of 30 inches. Safety glazing shall be installed in the following hazardous locations and be permanently labeled as safety or tempered glazing: glazing panels in doors; glazing enclosing spas, bathtubs or showers; glazing panels adjacent and within 24 -inches of the edge of a door; glazing panels greater than 9 square feet within 18 -inches of the floor; glazing used for railings; glazing used for barriers for swimming pools and spas; and glazing enclosing stairways, landings, and ramps within 36 -inches horizontally of a walking surface. (8308.4 through 308.4.7). j. Skylights must be: (IRC R308.6 ) A. laminated glass (with restrictions). B. fully tempered glass (with retaining screen). C. heat -strengthened glass (with retaining screen). D. wired glass (with retaining screen in multiple glazing condition only). E. approved rigid plastic. F. Skylight U -factor required U-0.45. Skylights installed on roofs flatter than 3 units vertical to 12 units horizontal must be mounted on a curb4-inches above the roof. Heating and Ventilation Requirements Crawl spaces shall be provided with conditioned air in compliance with Section N1102.2.10. Crawl space walls shall be insulated. Crawl space wall insulation shall be permanently fastened to the wall and extend downward from the floor to the finish grade level and then vertically and/or horizontally for a least an additional 24 -inches. Exposed earth in unvented crawl space foundations shall be covered with a continuous Class I vapor retarder with a minimum thickness of 10 -mil. All joints of the vapor retarder shall overlap by 6 -inches and be sealed and taped. The edges of the vapor retarder shall extend at least 6 -inches up the stem wall and shall be attached to the stem wall. N1102.2.9.2.2 Ventilated crawlspaces. Ventilated crawlspaces shall be provided with insulation. (IRC R303.1,) h ^ Habitable rooms must be provided with outdoor openings for ventilation equal to at least 4% of the floor area and shall have heating facilities capable of maintaining 68° at 3 -feet above the floor and 2 -feet from exterior walls. R. The windows need not be openable in a room where an opening is not required to be an egress window and a mechanical ventilation system is capable of producing 0.35 air change per hour in that room, or a whole house mechanical ventilation system provides 15 cubic feet of outdoor air per minute. k; Bathroom exhaust fans shall exhaust directly to the exterior and must be provided in bathrooms where windows of at least 3 square feet are not provided. The mechanical ventilation must be capable of providing an exhaust capacity of 50 cfrn intermittent or 20 cfin continuous exhaust. (IRC R303.3, M1507.4) 36 Dryer vents must be rigid metallic, independent of all other systems, shall terminate outside the building, be equipped with a back draft damper, and sized and terminated per the manufacturer. The maximum length of the exhaust duct shall be 25 -feet (Unless approved under the manufacturer's listing) from the connection to the transition duct from the dryer to the outlet terminal. Where fittings are used, the maximum length of the exhaust duct shall be reduced in accordance with (IRC Table M1502.4.4.1) Flexible transition ducts are limited to 8 -feet, shall not be concealed within construction, and shall be listed and listed per UL 2158A. (IRC M1502) 37 Appliances and equipment shall be installed in accordance with the conditions of their listing. Manufacturer's installation instructions must be available at the time of the inspection. (IRC G2408.1, M1307.1, M1401.1,M1902.2) 38 Appliances shall be accessible for inspection, service, repair and replacement without removing permanent construction. 30 -inches of working depth and width shall be provided in front of the control side of an appliance. (IRC M 1305.1) 39 Gas and solid fuel appliances located in a garage and hazardous locations shall be elevated so the source of ignition is at least 18 -inches above the floor. Rooms and spaces that are communicate directly with the garage and are not part of the living space shall be considered as part of the garage. Appliances located in garages must be installed at least 6 -feet above the floor or protected from motor vehicle impact. (IRC G2408.2, G2408.3) 40 Combustion air is required for all liquid fuel, solid fuel and gas appliances. (IRC M1701.1, G2407.1) Air for combustion, .ventilation and dilution of flue gases for appliances installed in buildings shall be provided with the requirement of (G2407.6 through G2407.9).One opening shall be 12" below the ceiling and one opening shall be 12 " above the floor. 41 Gas burning appliances may not be located in or obtain combustion air from: a sleeping room, bathroom, toilet room, or storage closet unless it is a direct vent appliance or installed in an enclosure that opens only into a bedroom or bathroom in and such enclosure is provided with a solid weather-stripped door, a self-closing device and all combustion air is taken from the outdoors. (IRC G2406.2) 42 Gas logs installed in solid fuel burning fireplaces shall be tested in accordance with ANSI Z21.60 and installed per the manufacturers installation instructions. Gas logs installed in bedrooms must be direct vent or provided with an approved source of outside combustion air. The approved gas log set must be installed in the Solid -fuel burning appliances at the final inspection. (IRC G2406, G2432, and G243 43 B, BW, and L vents and factory -built chimneys must be provided with a clearance to combustibles per them a manufacturer's listing. Where vents pass through insulated assemblies, they must be provided with an insulation shield. A clearance of 9 -inches is required between single wall vent connectors and combustibles. Gas vents must penetrate through the roof flashing, jack or thimble and terminate in a Chimneys listed cap or per the manufacturers listing. Decorative shrouds installed at terminations shall be listed and installed per the manufacturer. (IRC G2425, G2426, G2427) Electrical Requirements 44 All electrodes present at each structure shall be bonded together to form one grounding electrode system to include: Concrete Encased Electrodes (LIFER), water piping, ground rings, grounding rods, and plate electrodes. Bonding shall ensure electrical continuity. The electrode conductor must be connected in an approved manner and inspected prior to concealing. (IRC E3607, E3608, E3609, E3610, E3611) 45 All hot, neutral, and grounding conductors in electrical boxes shall be tied together with a mechanical connection at the time of rough inspection. Recessed lighting fixtures must either be IC -rated or installed in a sealed box in which the insulation is at least 3 -inches from the light fixture. All recessed lights must be tightly sealed or gasketed to prevent air leakage through the fixture into the ceiling cavity. (IRC N1102.4.5) Tamper -Resistant receptacle outlets are required in every kitchen, family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room or similar dwelling areas spaced so that no point along the wall line exceeds 6 -feet from an outlet. (IRC E3901, E3902, and 4002.1-4002.14) f,, Counters 12 -inches in width or wider shall have receptacles placed no more than 20 -inches above the counter top and spaced so no point exceeds 24 -inches from an outlet. 6. Island and peninsula counters with a length at least 24 -inches and a width of 12 -inches or greater must be equipped with at least one outlet.:. At least one receptacle shall be installed in a bathroom within 36 -inches of each basin. A least one receptacle outlet must be installed in each laundry, basement, attached garage and detached garage with power. Attics or crawlspaces containing equipment must be provided with at least one receptacle outlet within 25 -feet of the equipment. 1) Hallways 10 -feet or more in length.(E3901.1) �' Two 20 -amp rated branch circuits shall serve receptacles in the kitchen, pantry, breakfast area, and dining area. �At least one 20 -amp branch circuit shall supply bathroom receptacles and at least one 20 -amp branch circuit shall supply laundry. (IRC E3703.2, E3703.3, E3901) �,'1 Ground fault protection shall be provided on all 125 -volt, single phase, 15 and 20 -amp receptacles in the following locations: bathrooms, garages, unfinished grade level accessory buildings, at exterior locations, crawlspaces, unfinished basements, kitchen counters, within 6ft. of laundry, utility and wet bar sinks, boathouses, hydro massage, spa and hot tub locations. Receptacles must be in a readily accessible location. (IRCE3902, E3902.11) F<. Combination type arc -fault circuit interrupters must be installed on all 120 -volt 15 and 20 -amp branch circuit outlets in receptacle outlets are required in every family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room, hallway, closets, and similar dwelling areas. (IRC 3902.12) L At least one wall switch -controlled lighting outlet shall be installed in every habitable room, bathroom, hallway, (1 Oft) stairway, attached garage, detached garage with electric power, and at the exterior side of each outdoor egress door having grade level access. Attics, under floor spaces, utility rooms and basements containing equipment or used for storage must be provided with a switch operated light. (IRC E3903) Smoke alarms shall comply with UL 217. Smoke alarms are to be powered by the building's wiring with battery backup and shall be interconnected so the actuation of one alarm will activate all alarms in the dwelling unit.(R314.5) Smoke alarms shall be installed in the following locations: (IRC R314) A. In each sleeping room; 9 Outside each sleeping area in the immediate vicinity of the bedrooms; and " One on each additional story including basements. Carbon Monoxide alarms are required in a single-family dwelling that has fuel -fired appliance(s), or a fireplace, or an attached garage. The alarm must be installed within I5 -feet of the entrance to each sleeping room. Must be listed by a nationally recognized, independent lab. Plugs into a dwelling's electrical outlet and has a battery backup. They may be combined with a smoke -detecting device if the combined device complies with applicable law. (IRC R315) Clothes closet lighting shall be limited to surface -mounted or recessed incandescent fixtures with completely enclosed lamps, and surface -mounted or recessed fluorescent fixtures. Recessed fluorescent fixtures shall have a minimum 6 -inch clearance to the nearest point of storage. , . Working space must be provided around energized equipment for servicing and maintenance. The minimum dimensions shall not be less than 36 -inches in depth and 30 -inches in width in front of the equipment. Working space shall extend to at least 6 -feet, 6 -inches above the floor. (IRC E3405.2) '/ Electrical fixtures installed in wet or damp locations shall be installed so that water cannot enter or accumulate n wiring compartments or other electrical parts. Fixtures installed in wet locations must be labeled "suitable for wet locations". Fixtures installed in damp locations must be labeled "suitable for damp locations" or "suitable for wet locations". Switches or circuit breakers located in wet locations or outdoors must be enclosed in a weatherproof enclosure. Outdoor receptacles must have a weatherproof enclosure and an in -use cover. Cord -connected fixtures, hanging fixtures, track lighting, pendants, and ceiling fans shall not be located within3-feet horizontally and 8 -feet vertically from the top of a tub or shower rim. (IRC E4003.9, E4002.8, E4002.9,E4002.10, E4003.9, E4003. I 0,E4003.1 1) Plumbing S9, DWV systems shall be tested on compellation of the rough piping installation by water or for piping system other than plastic by air with no evidence of leakage. Either test shall be applied to the drainage system in its entirety or in sections after rough piping has been installed .1 ) Water test 10 feet above the highest fitting connection or to the highest point of the completed system. The system shall prove leak free for 15 minutes. �) Air test shall maintain 51bs of pressure for 15 minutes. 9 Piping must be inspected and tested prior to concealing. It shall be protected against physical damage and it must be approved for use and bear the identification of the manufacturer. (IRC P2503, P2603, P2608.1) 60 Bathtubs, walls above bathtubs with shower heads, shower floors, and shower compartments shall be finished with a non-absorbent surface which extends to a height not less than 6' above the floor. Showers must have a minimum 900 square inches of interior area and a minimum dimension in each direction of 30 -inches. Shower valves must be pressure balance/thermostatic mixing valves. Shower receptors shall have a curb threshold not less than 1 -inch below the sides and back of the receptor. The curb shall measure a minimum of 2 - inches to a maximum of 9 -inches above the top of the drain. (IRC R307, P2708, P2709) 6 P The centerline of toilets or bidets shall not be less than 15 -inches from adjacent walls or tub. Toilets, bidets, and lavatories must have a minimum clear space of 21 -inches in front of the fixture. Lavatories require a 4 -inch clearance to wall or to a toilet. (IRC P2705) 6� Showers and tub/shower combinations shall have control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with high limit stop per ASSE 1016 or CSAR 125.1. Tubs shall also have a control valve as listed for a shower or a water -temperature -limiting device that conforms to ASSE 1070. The high limit stop for a device shall be set to a maximum of 1200. (IRC P2708.3,P2713.3) 6:� Shower doors shall have safety glazing, hinged shower door shall open outward (R308.4.5, P2708.1) V Backflow prevention must be provided to prevent contamination of potable water. This includes but is not limited to: hose connections, irrigation systems, boilers, solar systems, fire sprinklers, and dishwashers. (IRCP2902.2, Table P2902.3, P2717) Insulation 6k, R-20 Walls (new construction ) R-49 Ceiling R-19 Crawlspace Windows .32 Floor R-30 6,6 Supply Ducts in attics shall be insulated to a minimum of R-8. All other ducts shall be insulated to minimum R-6. ( N 1103.2. 1) 6'1 Combustible insulation shall be separated a minimum of 3 -inches from fan motors and heat -producing devices. Insulation shields must be provided where vents pass thorough insulated assemblies and must terminate at least 2 -inches above attic insulation materials. Can lights must be airtight if located in the building envelope. Wallboard Requirements Wallboard Requirements 6� The garage shall be separated from the residence and its attic by materials of not less than 1/s -inch gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5/8 -inch Type X gypsum board. Openings between the garage and residence shall be equipped with solid wood doors not less than 1 -inch in thickness, solid or honeycomb core steel doors not less than 1 -inch thick, or 20 -minute fire -rated doors. Openings are prohibited between garages and rooms used for sleeping. Doors between attached garages and living space shall be weather stripped to the degree necessary to make them airtight and shall be self-closing and self -latching. (R302.5.1) 64 Enclosed accessible space under stairs shall have walls, under stair surface and any soffits protected on the enclosed side with 1/i -inch gypsum board (IRC R302.7). /U Cement, fiber -cement, glass mat gypsum backer and fiber reinforced gypsum in compliance with ASTM C 1288, C 1325, C1178, or C1178 and installed in accordance with manufacturer recommendations shall be used as backers for wall tile in tub and shower areas and wall panels in shower areas. (IRC R702.4.2) Nail spacing for gypsum board 1/2 Ceiling 16oc 7 nails 12 Type S screws, '�,/2wasi spacing 24"oc 8"nails, 12 "screws. 5/8 cei4ig 16oc 7" nails 12"type S screws 5/8 dell 24oc 8"nails 12" type S screws. Water-resistant gypsum backing board used as the base or backer for adhesive application of ceramic tile or other required nonabsorbent finish material shall conform to ASTM C1396 , C1178 or C1278. All cuts and exposed edges shall be sealed. (IRC 8702.3.8) Final Inspection Requirements Buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. 4" high, with a minimum stroke of 1/2" (IRC 319) `rl All dwellings shall have a controlled method of water dispersal from roofs that will collect and discharge all roof drainage at least 5 -feet from the foundation. Gutters, downspouts, downspout extensions shall be deemed adequate to meet these requirements. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6 -inches within the first 10 -feet. (IRC R401.3 and 801.3) Bill Myers Plans e mi nes ner/ Combination Inspector 7500 W. 2911 Ave Wheat Ridge, Co 80033-8001 303-235-2878 xr iiiiiiiii lllppllllll;��� pi 9J, t7 - 16-JIF 16 -9 o 7T, A iws�6e:,TtPJ ;OF -wc TT )—ft 9J, t7 - 16-JIF 16 -9 o 7T, M —7 E)(1 SB; tAef, 4 , wim t Ap CUT ++ Y _NY1 t+ SIS' to 7 16059 3 94 J R �a 100161 A4014ANa Cecil Rickstrew, P.E. 1627 Glen Moor Dr. Lakewood, CO 80215 July 16, 2017 Jeff Wood Jeffwoodwoodwork@gmail.com RE: 3090 Reed St., Wheat Ridge, CO Jeff Ph #: 303-668-2382 E-mail: Cecil Pecsidenver.com This letter shall serve as this engineer's field inspection report of 7-14-17 with respe;.t to he above referenced 10 1960 +/- constructed home. The inspection revealed the developer wanted to remove main floor bearing walls supporting ceiling joist and roof joist supports. 1. The developer wanted to remove the bearing wall between the east kitchen and the west living room area which will require a 24' span drop beam of (3) 1 j/" x 14"' LVLs supported on (2) 2x6 columns as shown in elevation 1 looking west on the at*acined page. The developer wants to remove two hall way 12' bearing walls at the south end of t'hE home to make a large master bedroom. Such will require a drop beam of (2) 12W, 9 ;h" LVL to support the ceiling joist and roof joist supports. a. The west hall way bearing wall aligns directly over a basement bearing wall below ano new prop beam and columns is shown on the attached page of elevation 2 looking west. The east hall way bearing wall bears on the floor joist, thus the new north column must be supported by two additional 2 x10 floor joist installed in the main floor directiv under the north column as shown in elevation 3 looking west as f.Dund :o, the attached page. 3. 'The existing double 2x10 header at the stair to the basement doesn't allow ror the required 6'8" clear headroom from the toe of the stair tread to the header above. The .solution is to remove the double 2x10 header which project below the 3' halfway into me stairs and install a 1 %" x S %z" LVL header directly above the ends of the joist: as shown in Section 4 on the attached page. Undertaking the remediation as referenced above will leave the home structurally sound in the area or remediation. _\1'R 1_ \0IF E recil Rickstrew, P.E. �i used ut hurlding design �.•,� , n, h nL. ,i `Load------------------------ ----------------------------------- V, ----- ----- ---- Vinu Load------------------------------------------------------- L ------------------------------------------ L n calfosn'i bD seismic Loads ----------------- SeismiccassdSeismic ; ,nplicable Code is IRC 201-5 .fall, UV t -S� _. ��%<•od: ��- ll framins< lumber shall be Doug Fir . or better or equal i aN� resistant. ';. f'rc:-engineered lumber shall be by truss .foist for- Ijoist n licr�tl,tn, [or >'Ls I F b>=?800 P.s.i. j. LVL beams shall be secured togethcr ti,it;: i cd tr::.r<s ai 11- o.c. each top and bottom uniess otherwise noted. t lruming connectors shall be bt SiMP',011 Stron-_, l ic. Antoinette Kulick From: Antoinette Kulick Sent: Monday, November 6, 2017 9:54 AM To* 'Jeffwoodwoodwork@gmail.com' Cc: Brian Tardif; Kimberly Cook S►:bject: 3090 Reed St Hi Jeff, Your plans for the remodel at the above stated address have been approved, however in the review we noticed you have asbestos as called out in the report submitted. If you are abating the asbestos we need the abatement report as well as the permit from the state of Colorado. Once this has been received, the total balance due is $2069.10. Prior to permit issuance we need a General Contractor on record as well as any and all subs ie, Electrician, Plumber, Mechanical contractor etc. Our counter hours for this type of permit are 7:30am-10:30am. Please let me know if I can be of further assistance. Sincerely, Antoinette Kulick Permit Technician 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2873 Fax: 303-237-8929 www.ci.wheatridge.co.us t ily of W h6at j is lge L. ��lththHl:l;lt� i�1'4'ttc�l�".1IVI CONFIDENTIALITY NOTICE: This e-mail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received Ns communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you. City of Whcatijdgie COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29`h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permitsCcbci.wheatridge.co.us FOR OFFICE USE ONLY Date: AP V j 7 Plan/Permit # Plan Review Building Permit Application *'* Please complete all highlighted areas on both sides of this form. Incomplete applications Property Address: 0 ?0 L i be processed."" Property Owner (please print): C�JC-c . tri , r -k Ke a CS 7e- Phone: 30:5.. Property Owner Email: e.v o s� �,�.. re-) IP, -1-341Y : c_c► ,.. Mailing Address: (if different than property address) Address: I /-- T,_.L',s r, Zip: L t' -,j re j v , A / cc Architect/Engineer E-mail: Ccc-j' Contractor:ti (* -,o �1 I Contractors City License #: ti / 1 & Contractor E-mail Addres i n lit, i i fr � Sum Contractors: Electrical: VV j b � y (C' Plumbing: W.R. City License # �2111 1 W.R. City License # Other City Licensed Sub: City License # 1S_ Phone: 3 c ad, Other City Licensed Sub: City License # _5-35F Mechanical: W.R. City License # Complete all information on BOTH sides of this form 5366 Godding Hollow Parkway Longont, CO 80504 EARTH ENERGY ENVIRONMENT (E3) Local: 303.4778-0922 Industrial Hygiene and Environmental Engineering August 11, 2017 Mr. Jeff Wood Property Representative 3090 Reed Street, Wheat Ridge, CO Subject: Asbestos Sampling Results — 3090 Reed Street, Wheat Ridge, CO Dear Jeff: On August 9 2017, an Industrial Hygienist with Earth Energy Environment (E3) performed an inspection and asbestos sampling on a residential property located at 3090 Reed Street, Wheat Ridge, CO. E3 was retained by a property representative to determine if the accessible building materials within the property contain asbestos. SURVEY METHODOLOGY An industrial hygienist from E3 conducted the sampling. Materials were grouped into homogeneous sampling areas based on the material type. Among the interior building materials, fourteen (14) distinct homogeneous areas throughout the property were identified and sampled. Homogeneous Material Classifications A preliminary walk through of the buildings was conducted to determine areas of materials which were visually similar in color, texture, general appearance, and which appeared to have been installed at the same time. Such materials have been termed "homogeneous materials" by the EPA. During this walk through, the approximate locations of these homogeneous materials were noted. a Following the EPA inspection protocol, each identified suspect homogeneous material was placed in one of the following EPA classifications: Surfacing Materials - Sprayed or troweled on surfaces (walls, ceilings, structural members) for acoustical, decorative, or fireproofing purposes. This includes plaster and fireproofing insulation. Miscellaneous Materials - Other non -friable products and materials such as floor tile and ceiling tile. Thermal System Insulation - Insulation used to inhibit heat transfer or prevent condensation on pipes, boilers, tanks, ducts, and various other components of hot and cold water systems and hearing, ventilation, and air conditioning (VAC.) systems. This includes pipe lagging, pipe wrap, block, batt, blanket insulation, cements, muds, gaskets and ropes. (These materials were not sampled as part of the survey.) 21Page Friability Classifications Friable and non -friable ACM's are defined as follows: Friable asbestos -containing material: any material containing more than 1% asbestos, determined using PLM analysis, that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Category I nonfriable asbestos -containing material: asbestos -containing resilient floor covering, mastic or asphalt roofing product containing more than 1% asbestos as determined using PLM. Category II nonfriable asbestos -containing material: any material, excluding Category I non -friable ACM, containing more than 1% asbestos as determined using PLM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. Regulated asbestos -containing material (RACM): (1) friable ACM, (2) Category I nonfriable ACM That has become friable, (3) Category 1 nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (4) Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the materials in the course of demolition or renovation operations. Sampling and Laboratory Analysis Bulk samples were collected by using various sampling tools (cutting tools, knives and chisels) to cut away or scrape portions of suspect building materials into zip -sealed plastic bags or sampling tubes. The individual samples were labeled by material type and location. Samples were analyzed by Reservoirs Environmental Laboratory located in Denver, CO. The laboratory maintains accreditation through the American Industrial Hygiene Association (AIHA), and National Voluntary Laboratory Accreditation Program (NVLAP). The analysis performed was EPA Method 600/R-93/116. INSPECTION RESULTS E3 collected at least the minimum number of samples from each homogeneous area necessary to meet all regulatory requirements for the quantity of material to be observed. Table 1 provides a summary of the homogenous areas. 31 Page Table 1. Homogeneous and Functional Sampling Areas. Material Material Physical Classification Samples HA Type Description Description Collected 1 Attic Debris Insulation A Black debris Thermal System 3 Insulation Insulation 2 Floor Debris Demolition A Off white/multi-colored debris Surfacing 3 Debris on Floors Materials A Brown gold/black resinous 3 Bathroom Walls material Surfacing 3 Walls B Off white granular plaster Materials C White plaster A Tan resinous material 4 Kitchen Wks B White plaster w/ beige/multi- Thermal System 3 Walls colored paint Insulation C Off white granular plaster A White plaster w/ pink paint Surfacing 5 Stair Walls Walls B Light pink granular plaster Materials 3 C White/tan all Light Green A White plaster w/ light green 6 Walls and Walls and paint Surfacing 5 Ceilings Ceilings B White/tan drywall Materials C Light pinkgranular plaster Back A White texture w/ pink paint B Surfacing 7 Bedroom Walls White plaster w/ pink paint Materials 3 Walls C Light pink granular plaster A White/pink flooring w/ white 8 Bathroom Vinyl Floors fibrous backing material Surfacing 3 Floors B pink flooring w/ black felt Materials backing material Kitchen 9 Floor Vinyl Floors A Green/multi-colored flooring Surfacing 3 (Layer 1) Materials 10 Ceiling Tiles 1 foot x 1 feet A Brown/white ceiling tile Surfacing 3 ceiling tiles Materials A Tan adhesive 11 Basement 9 inch by 9 inch B Gray granular cementitious Surfacing 3 9x9 tiles floor tiles material C Off white/multi- Materials colored sheet vinyl A Black adhesive 12 Kit Floor Vinyl Flooring B Off white/multi-colored sheet Surfacing 3 (Layer 2) vinyl w/ black fibrous backing Materials material A Brown adhesive 13 Kit Floor Vinyl Flooring B Off white sheet vinyl w/ gray Surfacing 3 (Layer 3) fibrous backing material Materials 14 Duct Wrap A Tan fibrous material Miscellaneous 3 Materials 41 Page The laboratory separated and analyzed individual layers within each sample, if present. According to the laboratory analysis of the materials sampled, asbestos was detected in bathroom within the flooring and brown resin on the walls. The duct wrap was not samaled, but is assumed to be asbestos containing. Table 2. Asbestos Containing Materials HA Material Type Material Physical Asbestos Description Description Content Bathroom A Bro%"i guiu: wa , icmiuus material 15 3 Walls Glue/Resin B Off white granular plaster otile Chrysotile o C White plaster Bathroom Vinyl A White/pink flooring w/ white fibrous 25% 8 Floors Flooring backing material Chrysotile B Pink flooring w/ black felt backing material 13 Duct Wrap �g/ A Tan fibrous material Assumed Sealant Wrap Chrysotile Bathroom Black/Gold Resin Bathroom Flooring Duct Wrap 51 P(7 CONCLUSIONS AND RECOMMENDATIONS According to the laboratory analysis of the interior building samples. asbestos was detected in the bathroom flooring and wall resin. The duct wrap was not sampled, but is assumed to be asbestos containing. A portion of the flooring (12 square feet) and the bathroom wall resin (15 square feet) were disturbed by the remodeling activities. The bathroom is therefore considered a minor spill area. Visual inspect indicates the spill is limited to within the bathroom. A minor spill response followed by remediation/removal of the asbestos containing materials by a Colorado Certified Abatement contractor is recommended. The Colorado Department of Public Health and the Environment requires any asbestos -containing material that is friable or will be made friable during demolition/renovation activities be removed prior to demolition or renovation. Any potential asbestos containing materials identified in the future or during demolition that were not sampled in this, or any other previous survey, should be tested for asbestos content or assumed to contain asbestos before being disturbed. If you have questions or require additional information, please contact me at (303) 478-0922. Sincerely, Art Willden Certified Building Inspector No. 20138 Reservoirs Environmental, Inc. Effective January 1, 2015 Reservers Emironmemal QA Manual TAQAWLab'R—ars Em—mental QA Manual doe --� AEReservoirs Environmental, Inc. WOW August 10, 2017 Earth Energy and Environment Corp. 5366 Godding Hollow Pkwy Longmont CO 80504 Dear Customer, Subcontract Number: NA Laboratory Report: RES 386864-2 Project # / P.O. # None Given Project Description: 3090 Reed Street Wheatridge Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 386864-2 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, Jeanne Spencer President P: 303-9641986 5801 Logan Sheet, Suite 100 Denver, CO 80216 1-866-RESI-ENV F: 303-477-4275 wvw_reilab.com Page 1 of 1 Reservers Environmental, Inc. Reservoirs Emironmental OA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/R-931116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effective January 1, 2015 Q \QAQ01-A13XR rvdrs Emironmemal OA Manual doc ND=None Detected ___e..-_._.. TR=Trace, <1 % Visual Estimate ITrem/Act=Tremolite/Actinolite Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R (%) Asbestos Content Mineral Visual Estimate (%) Non Asbestos Fibrous Components Non - Fibrous Components Attic Debris -1 EM 1917633 A Black debris 100 ND 5 95 Attic Debris -2 EM 1917634 A Black debris 100 ND 5 95 Attic Debris -3 EM 1917635 A Black debris 100 ND 2 98 Floor Debris -1 EM 1917636 A Off white/multicolored debris 100 ND 2 98 Floor Debris -2 EM 1917637 A Off white/multicolored debris 100 ND 5 95 Floor Debris -3 EM 1917638 A Off white/multi-colored debris 100 ND 10 90 Bath Walls -1 EM 1917639 A Off white granular material 2 ND 0 100 B White plaster 98 ND 0 100 Bath Walls -2 EM 1917640 A Off white granular plaster 10 ND TR 100 B Off white/tan drywall 90 ND 15 85 Bath Walls -3 EM 1917641 A Brown gold/black resinous material 10 Chrvsotile 16 0 85 B Off white granular plaster 15 ND TR 100 C White plaster 75 ND 0 100 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1 %. P 303-964-1986 5801 Logan Street, Suite 100, Denier, CO 80216 F' 303-077-4275 1RENV e0.b P— 1 0" flab -corn Reservoirs Emironmental, Inc. Reservan, Environmental QA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number/ P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effective January 1, 2015 QAQAQCV.AMReservoim Environmemal QA Manual doc ND=None Detected TR=Trace, a1% Visual Estimate ITrem/Act=Tremolite/Actinolite Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R (%) Asbestos Content Mineral Visual Estimate Non Asbestos Fibrous Components Non - Fibrous Components Kit Walls -1 EM 1917642 A Tan resinous material 25 ND 0 100 B White plaster w/ beige/multi-colored paint 25 ND 0 100 C Off white granular plaster 50 ND TR 100 Kit Walls -2 EM 1917643 A White plaster w/ yellow/multi-colored paint 25 ND 0 100 B Off white granular plaster 75 ND TR 100 Kit Walls -3 EM 1917644 A Tan resinous material 10 ND 0 100 B White plaster 10 ND 0 100 C Off white granular plaster 80 ND TR 100 Stair Walls -1 EM 1917645 A White paper w/ pink paint 50 ND 0 100 B Light pink granular plaster 50 ND 0 100 Stair Walls -2 EM 1917646 A White plaster w/ pink paint 25 ND 0 100 B Light pink granular plaster 35 ND TR 100 C White/tan drywall 40 ND 15 85 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1 %- P 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI-ENV F_ 303-077-4275 Pace 2 of _ www.reilab.com Reservoirs Environmental, Inc. Reservoirs Emnonmental OA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effeaive January 1, 2015 0 \OAOCUABUteservoits Environmerrial OA Manual.00c ND=None Detected u� jTR=Trace, <1% Visual Estimate Trem/Ad=Tremolite/Actinolite I Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R (%) Asbestos Content Mineral Visual ; Estimate Non Asbestos Fibrous Components Non - Fibrous Components Stair Walls -3 EM 1917647 A Light pink granular plaster 45 ND TR 100 B White plaster w/ pink paint 55 ND 0 100 Swirl Ceiling -1 EM 1917648 A White plaster w/ white paint 50 ND 0 100 B Light pink granular plaster 50 ND TR 100 Swirl Ceiling -2 EM 1917649 A Light granular plaster 40 ND 0 100 B White plaster w/ off white paint 60 ND 0 100 Swirl Ceiling -3 EM 1917650 A Light pink plaster 35 ND 0 100 B White plaster w/ white paint 65 ND 0 100 Lt Green W/C-1 EM 1917651 A Light pink granular plaster 15 ND 0 100 B White plaster w/ light green paint 85 ND 0 100 Lt Green W/C-2 EM 1917652 A Light pink granular plaster 20 ND 0 100 B White plaster w/ light green paint 80 ND 0 100 Lt Green W/C-3 EM 1917653 Sample Not Received. TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-9641986 5801 Logan Street, Suite 100, Denver, CO 80216 1-868-RESI-ENV F 303-477-0275 —reilab.c— Page 3 or - Sat, Aug 19 04:00 PM - 05:45 PM Colorado Legacy (Dean) vs. RMT (Goodnight) Sat, Aug 19 04:00 PM - 05:45 PM Untouchables (Graves) vs. Wolves (Sprague) Sat, Aug 19 04:00 PM - 05:45 PM 14 Raptors Black (Odonnell) vs. Warriors Cardinal (Page) GAME Englewood, Cornerstone 2 GAME Englewood, Cornerstone 1 GAME Parker, Iron Horse #2 Sat, Aug 19 05:45 PM - 07:30 PM RMT (Goodnight) vs. Untouchables (Graves) GAME Englewood, Cornerstone 1 Reservoirs Environmental, Inc. Reservoirs Environ ental QA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101856-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effective January 1, 2015 QAQAQCV.ABtReservoirs Environmental QA Manual.doc ND=None Detected v-' TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite i Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R (%) Asbestos Content Mineral Visual Estimate Non Asbestos Fibrous Components Non - Fibrous Components Lt Green W/C-4 EM 1917654 A White plaster w/ light green paint 10 NO 0 100 B White/tan drywall 40 ND 15 85 C Light pink granular plaster 50 ND TR 100 Lt Green W/C-5 EM 1917655 A White plaster w/ light green paint 10 ND 0 100 B White/tan drywall 35 ND 20 80 C Light pink granular plaster 55 ND TR 100 Lt Green W/C-6 EM 1917656 A White plaster w/ light green paint 10 ND 0 100 B White/tan drywall 40 ND 15 85 C Light pink granular plaster 50 ND TR 100 Back Brd Multi Color Walls -1 EM 1917657 A White texture w/ pink paint 15 ND 0 100 B White plaster w/ pink paint 20 ND 0 100 C Light pink granular plaster 65 ND 0 100 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P. 303-964-1986 5601 Logan Street Suite 100, Denver, CO 80216 14886-RESI-ENV P: 303-477-4275 Page 4 of 7 ,wMtreilab.com Sat, Aug 19 12:30 PM - 02:15 PM BC Green (Salgado) vs. Hawks White (Betschart) GAME Englewood, Cornerstone 1 Sat, Aug 19 12:30 PM - 02:15 PM Eagles White (Martinez) vs. Spartans White (Klatt) GAME Parker, Iron Horse #2 Sat, Aug 19 12:30 PM - 02:15 PM Hawks Blue (Wickstrom) vs. Warriors Fire (Burtt) GAME Parker, Iron Horse #1 Sat, Aug 19 12:30 PM - 02:15 PM Warriors Crimson (Gooden) vs. Warrior Red (Lohani) GAME Englewood, Cornerstone 2 Sat, Aug 19 12:30 PM - 02:15 PM Denver War Eagles (Fee) vs. Prodigy (Acree) GAME Aurora, Mission Viejo # 1 Sat, Aug 19 12:30 PM - 02:15 PM RMT (Cameron) vs. Colorado Peak (Maestretti) GAME Aurora, Mission Viejo # 2 Sat, Aug 19 12:30 PM - 02:15 PM Colorado Legacy (Hagardt) vs. RMT (Reimers) GAME Aurora, Mission Viejo # 4 Sat, Aug 19 12:30 PM - 02:15 PM Eagles Riptide (Franco) vs. Eagles Green (Beranek) GAME Aurora, Mission Viejo # 3 Sat, Aug 19 02:15 PM - 04:00 PM Colorado Legacy (Dean) vs. Rado Eagles (Shellhorn) GAME Englewood, Cornerstone 3 Sat, Aug 19 02:15 PM - 04:00 PM Warriors Steel (Mimless) vs. Warriors Crimson Gooden Sat, Aug 19 02:15 PM - 04:00 PM Warriors Iron (Barbre) vs. 14 Raptors Black (Odonnell) Sat, Aug 19 02:15 PM - 04:00 PM 14 Hawks Orange (Weiman) vs. Hawks Green (Cunningham) GAME Englewood, Cornerstone 2 GAME Parker, Iron Horse #2 GAME Parker, Iron Horse #1 Sat, Aug 19 02:15 PM - 04:00 PM Warriors Cardinal (Page) vs. 14 Hawks Blue (Adams) GAME Parker, Iron Horse #3 Sat, Aug 19 02:15 PM - 04:00 PM Hawks White (Betschart) vs. Hawks Orange (Bachli) GAME Englewood, Cornerstone 1 Sat, Aug 19 02:15 PM - 04:00 PM Crush (Mitchell) vs. RMT (Heathcoat) GAME Castle Rock, DCFG 1 Reservoirs Environmental, Inc. Reservoirs Environmental OA. Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effective January 1, 2015 O \DAOCLLAB%Reservoirs Environmental QA Manual.00c ND=None Detected m1 ITR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R Asbestos Content Mineral Visual ? Estimate Non Asbestos Fibrous Components Non - Fibrous Components Back Brd Multi Color Walls -2 EM 1917658 A White plaster w/ pink/multi-layered paint 45 ND 0 100 B Light pink granular plaster 55 ND 0 100 Back Brd Multi Color Walls -3 EM 1917659 A Light pink granular plaster 10 ND 0 100 B White plaster w/ purple paint 90 ND 0 100 Bath Floor -1 EM 1917660 A White/pink flooring w/ white fibrous backing material 48 Chrysotile 25 5 70 B Pink flooring w/ black felt backing material 52 ND 45 55 Bath Floor -2 EM 1917661 Not Analyzed per Client Request. Bath Floor -3 EM 1917662 Not Analyzed per Client Request Kit Floor -1 EM 1917663 A Green/multi-colored flooring 100 ND 0 100 Kit Floor -2 EM 1917664 A Green/multi-colored flooring 100 ND 0 100 Kit Floor -3 EM 1917665 A Green/multi-colored flooring 100 ND 0 100 Ceiling Tiles -1 EM 1917666 A Brown/white ceiling tile 100 ND 85 15 Ceiling Tiles -2 EM 1917667 A Brown/white ceiling tile 100 ND 90 10 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1 %. P: 303-964-1986 5801 Logan Street Suite 100, Denver, CO 80216 1-866-RESI-ENV F: 303477-4275 Page 5 of ] —'/.reila0.com Sat, Aug 19 10:45 AM - 12:30 PM Raptors Green (Steiner) vs. Eaqles White (Varholak) GAME Englewood, Cornerstone 1 Sat, Aug 19 10:45 AM - 12:30 PM RMT (Heathcoat) vs. EC Coyotes (Hayes) GAME Castle Rock, DCFG 3 Sat, Aug 19 10:45 AM - 12:30 PM Eagles Green (Maloney) vs. RMT (Lewis) GAME Castle Rock, DCFG 2 Sat, Aug 19 10:45 AM - 12:30 PM 14 BC Legends (Garcia) vs. Warriors Crimson GAME Parker, Iron Horse #1 (Weiss) " time change Sat, Aug 19 12:30 PM - 02:15 PM Wolves (Sprague) vs. Rado Eagles (Shellhorn) GAME Englewood, Cornerstone 3 Sat, Aug 19 12:30 PM - 02:15 PM All American (Romero) vs. Untouchables (Martinez) GAME Castle Rock, DCFG 1 Sat, Aug 19 12:30 PM - 02:15 PM RMT (Lewis) vs. Crush (Madison) GAME Castle Rock, DCFG 2 Sat, Aug 19 12:30 PM - 02:15 PM Prodigy (Simco) vs. Psyclones 04 (Kinder) GAME Castle Rock, DCFG 3 Sat, Aug 19 12:30 PM - 02:15 PM Warriors Black (Kunz) vs. Eagles Black (Broadrick) GAME Highlands Ranch, Northridge 3 Sat, Aug 19 12:30 PM - 02:15 PM Hawks Green (Cunningham) vs. Warriors Iron GAME Parker, Iron Horse #3 Barbre " * time change Sat, Aug 19 12:30 PM - 02:15 PM Hawks White (Reed) vs. Warriors Scarlet (Farley) GAME Highlands Ranch, Northridge 2 Sat, Aug 19 12:30 PM - 02:15 PM Spartans Gold (Stevens) vs. Hawks Blue (Carpenter) GAME Highlands Ranch, Northridge 1 Reservoirs Environmental, Inc, Reservoim Ernironnneral QA Manuel RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effective January 1, 2015 Q \QAQC%A81Reservoim Enviromnental QA Manual.doe ND=None Detected TR=Trace, <1 %Visual Estimate Trem/Act=Tremolite/Actinolite I Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R Asbestos Content Mineral Visual i Estimate Non Asbestos Fibrous Components Non - Fibrous Components Ceiling Tiles -3 EM 1917668 A Brown/white ceiling file 100 ND 85 15 Basement 9X9-1 EM 1917669 A Tan adhesive 2 ND 0 100 B Gray granular cementitious material 2 ND 0 100 C Off white/multi-colored sheet vinyl 96 ND 0 100 Basement 9X9-2 EM 1917670 A Tan adhesive 1 ND 0 100 B Off white/multi-colored sheet vinyl 99 ND 0 100 Basement 9X9-3 EM 1917671 A Tan adhesive 2 ND 0 100 B Off white/multi-colored sheet vinyl 98 ND 0 100 Kit Floor -2-1 EM 1917672 A Black adhesive 1 ND 0 100 B Off white/multi-colored sheet vinyl w/ black fibrous 99 ND 75 25 backing material Kit Floor -2-2 EM 1917673 A Black adhesive 2 ND 0 100 B Off white/multi-colored sheet vinyl w/ black fibrous 98 ND 75 25 backing material TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1 %. P 301964-1986 5801 Logan Street Suite 100, Denier, CO 80216 14P66-RE51-ENV F: 303-477-4275 Page 6 of 7 vrcrv.reilab.com Sat, Aug 19 09:00 AM - 10:45 AM Hawks Orange (Woods) vs. Spartans White (Klatt) GAME Parker, Iron Horse #3 Sat, Aug 19 10:45 AM - 12:30 PM All American (Romero) vs. Crush (Mitchell) Sat, Aug 19 10:45 AM - 12:30 PM Eagles Green (Beranek) vs. Denver War Eagles Fee Sat, Aug 19 10:45 AM - 12:30 PM Eagles Black (Broadrick) vs. Spartans Purple (Camarillo) * * time change Sat, Aug 19 10:45 AM - 12:30 PM Eagles White (Heshmati) vs. Hawks White (Reed) GAME Castle Rock, DCFG 1 GAME Aurora, Mission Vieio # 4 GAME Highlands Ranch, Northridge 3 GAME Highlands Ranch, Northridge 2 Sat, Aug 19 10:45 AM - 12:30 PM Spartans Gold (Stevens) vs. Eagles Green (Gibson) GAME Highlands Ranch, Northridge 1 Sat, Aug 19 10:45 AM - 12:30 PM Warriors Fire (Burtt) vs. Eagles White (Martinez) GAME Parker, Iron Horse #2 Sat, Aug 19 10:45 AM - 12:30 PM Warriors Chrome (Shaffer) vs. Hawks Orange GAME Parker, Iron Horse #3 (Woods) Sat, Aug 19 10:45 AM - 12:30 PM Colorado Peak (Maestretti) vs. Eagles Riptide GAME Aurora, Mission Vieio # 2 Franco Sat, Aug 19 10:45 AM - 12:30 PM BC Hot Shots (Burgess) vs. Colorado Jags (Page) GAME Aurora, Mission Vieio # 1 Sat, Aug 19 10:45 AM - 12:30 PM Spartans Black Comp (Sleesman) vs. BC Invasion GAME Aurora, Mission Vieio # 3 (Marquez) Sat, Aug 19 10:45 AM - 12:30 PM Hawks Orange (Bachli) vs. Raptors Gray (Whitaker) GAME Englewood, Cornerstone 3 Sat, Aug 19 10:45 AM - 12:30 PM Spartans Gold (Galka) vs. Warriors Steel (Mimless) GAME Englewood, Cornerstone 2 Reeervoira Environmental, Inc. Reservoirs Environmental QA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number/ P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Effective January 1, 2015 QAQAOCUAB\Reservoirs Environmental QA Manu.I doc Method: EPA 600/R -93M16 - Short Report, Bulk ND=None Turnaround: 2 Hour TR=Trace, Date Samples Analyzed: August 09, 2017 Trem/Act=Tremolite/Actinolite Detected <1 % Visual Estimate Client Lab L Asbestos Content Non Non - Sample ID Number A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) lob) (%) M) Kit Floor -2-3 EM 1917674 A Black adhesive 4 ND 0 100 B Off white/multi-colored sheet vinyl w/ black fibrous 96 ND 70 30 backing material Kit Floor -3-1 EM 1917675 A Off white sheet vinyl w/ gray fibrous backing material 100 ND 50 50 Kit Floor -3-2 EM 1917676 A Brown adhesive 5 ND 0 100 B Off white sheet vinyl w/ gray/blue fibrous backing material 95 ND 65 35 Kit Floor -3-3 EM 1917677 A Off white/brown adhesive 5 ND 0 100 B Off white sheet vinyl w/ gray/blue fibrous backing material 95 ND 60 40 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1 W Brianne Neumann Analyst Michael Scales Analyst / Data QA P: 303-964-1986 5801 Logan Street, Suite 100, Oenver, CO 00216 1-86&RESI-ENV F: 303-4773275 Page 7 of 7 rww.reilab.com 12:00 AM First Comp Games Sat, Aug 19 Begin Sat, Aug 19 09:00 AM - 10:45 AM RMT (Cameron) vs. Colorado Jags (Page) GAME Aurora, Mission Viejo # 2 Sat, Aug 19 09:00 AM - 10:45 AM Warrior Red (Lohani) vs. Spartans Gold (Galka) GAME Englewood, Cornerstone 2 Sat, Aug 19 09:00 AM - 10:45 AM Raptors Gray (Whitaker) vs. BC Green (Salgado) GAME Englewood, Cornerstone 3 Sat, Aug 19 09:00 AM - 10:45 AM BC Black (Orozco) vs. Raptors Green (Steiner) GAME Englewood, Cornerstone 1 Sat, Aug 19 09:00 AM - 10:45 AM Untouchables (Martinez) vs. Crush (Madison) GAME Castle Rock, DCFG 1 Sat, Aug 19 09:00 AM - 10:45 AM EC Coyotes (Haves) vs. Prodigy (Simco) GAME Castle Rock, DCFG 2 Sat, Aug 19 09:00 AM - 10:45 AM Psyclones 04 (Kinder) vs. Eagles Green (Maloney) GAME Castle Rock, DCFG 3 Sat, Aug 19 09:00 AM - 10:45 AM Eagles White (Heshmati) vs. Warriors Scarlet (Farley) GAME Highlands Ranch, Northridge 2 Sat, Aug 19 09:00 AM - 10:45 AM Warriors Black (Troxell) vs. Hawks Blue (Wickstrom) GAME Parker, Iron Horse #2 Sat, Aug 19 09:00 AM - 10:45 AM Hawks Black (Surina) vs. Warriors Chrome (Shaffer) GAME Parker, Iron Horse #1 Sat, Aug 19 09:00 AM - 10:45 AM RMT (Reimers) vs. BC Invasion (Marquez) GAME Aurora, Mission Vieio # 4 Sat, Aug 19 09:00 AM - 10:45 AM BC Hot Shots (Burgess) vs. Spartans Black Comp GAME Aurora, Mission Vieio # 3 (Sleesman) Sat, Aug 19 09:00 AM - 10:45 AM Colorado Legacy (Hagardt) vs. Prodigy (Acree) GAME Aurora, Mission Vielo # 1 Sat, Aug 19 09:00 AM - 10:45 AM Eagles Green (Gibson) vs. Hawks Blue (Carpenter) GAME Highlands Ranch, Northridge 1 Colorado Department of Public Health and Environment Air Pollution Control Division — Indoor Environment Program — Asbestos/IAQ Unit 4300 Cherry Creek Drive South, APCD-IE-B1 Denver, Colorado 80246-1530 Phone: 303-692-3100—Fax: 303-782-0278 E-mail: asbestos@state.co.us ASBESTOS ABATEMENT PERMIT This permit is granted subject to Colorado Air Quality Control Commission Regulation No. 8, Part B, adopted December 21, 2007, and effective January 30, 2008, the Colorado Air Pollution Prevention and Control Act (25-7-101 or 25-7-501 et seq., C.R.S.) and the following provisions. It is only for the purpose of allowing asbestos abatement. 1. ADDITIONAL PERMIT PROVISIONS: By performing work under this permit the abatement contractor agrees that the Division may revoke or suspend this permit should the Division find that the contractor: • has violated or has aided and abetted in the violation of 25-7-101 or 25-7-501 et seq., C.R.S. or Regulation No. 8, Part B, or an order of the Division or Commission, • has failed to meet any permit and notification requirement or failed to correct any violations cited by the Division during any inspection within a reasonable period of time, as may be determined by the Division, • has used misrepresentation or fraud in obtaining this permit, or, • has committed any act or omission which does not meet generally accepted standards of the practice of asbestos abatement. As a contractor, you may be subject to other licenses and permits, depending on the requirements of the county and municipality in which the work is being performed. The Colorado Department of Public Health and Environment, Air Pollution Control Division strongly suggests that you check with county and municipal authorities in order to determine any other local building/permitting requirements that must be met. THE ORIGINAL PERMIT MUST BE POSTED ON SITE AT ALL TIMES. Immediately notify the Asbestos/IAQ Unit of project modifications by fax (number above) or e-mail (address above) and the appropriate county health department by fax. Project modifications include changes in the scope of work or the scheduled work dates, etc. This asbestos abatement permit is valid beginning 9/4/2017 through 11:59 PM on 10/3/2017. The actual scheduled work dates are from 9/4/2017 through 9/8/2017. Approval issued on: 8/25/2017 Record number: 130353 Notice Number: 17DE5204A Variance: None Comments: None For the location specified below: Residential Throughout 3090 Reed St. Denver Denver County This permit has been issued to: Mile High Environmental Services, Inc. 9520 E. Jewell Ave Suite C Denver, CO 80247 Fee paid: $180.00 Check number: CC 2570 Project Supervisor: Fernando Vera -Jaime Cerification No.: 9458 Project AMS: Arthur Willden Cerification No.: 20138 Project Manager: Issued by: CA ci OZ U. Z OW F- cr- U co J JJ a. a� Q � H_0 � Q � U CL CCLQ LLJ 00- 0 a a° U? LL :� Oo ZLL Z = W~ 2z W a M O W Q Q O cn N2 WW 'w W LL Q d n � 3 ?� 3 aJ °� y 7 � u n� o= � 3 � G y y U I C C_ m <L U ' N > m EE E . 9 r� 3 >cc `��i O acc N N a i O y x O d to Zt Cl - 8 O x v� � 3 W d � 3 iJ N a0 80 vm ai rn a p1 E x C d c a u i `c O w E U y n C C p Cy L y Q d O O Q p E N 3 IV m '" E a y E ` O �L N O C O � Y � d M N na 0 L 4) C 0 CL 0 m c CCO c a U (p `- L y d a OJTG $ O U CL j C� L . y Y L d OC O O _ d O C c S ydE'm .L.. N O y 3 U rn c O 3^ y LL U 0 � m U O N L CU V d C � CD ;cp N G U) O W 0 a m 3 E CD 0 0 C) WI U 0 f a N n N d > . ! a C o d >o a��i ch a m�' mU in n Q 2 a m t o a a cc R d m O 3 O y LIJy x I C L O F LL H m Cuj OO U O b W !� a IA aGI 'ffim 6 LO LO m 0 din r 4" C C: M C1 # UQ vyi W M d w y � C E c 'c d E it 19 E d c �o c ZQ a d oo m Z a Q C cc i0t0 MO r W CN C Yf a ' O v in tv in iv a° w IL v i � I M do go a d u y o uW coLOE ~ N r N❑ �O g � uMi o� N Q3 W ® Lcc : i c L C Ql mi d 4 M � M � ::d E cnca d CLO" i d :? o �- a 10 a U Lj m o 01 w WC w o 8 ir E v c o c C :3 Q. n Z It p o Eli y Q>1 y E m o °' Q , ICdi Z 4 U do t C C - ¢ c 0 i'- Y C1 <L `0 '� `v r m r m y (D W m U) co (U m (n (A U (D � i p 0) G N y O1 cv U d d .mow c� iso O O D U2 Vco C a a` o d E a LL V ° ° ° 0.1 3 4. r a) °; L c Q = W > ; d > mE N p` CD = a E E cm Q o y ?m Z C d LA U. y W N and 2 ik tk ji C d 7t 0 Z L a d OD 00. (n d ti CA W CEO Z c CO mC1 dQ = QM. E y cu lul. 0.Z. N rn a oy U W u d I u"' d n � 3 ?� 3 aJ °� y 7 � u n� o= � 3 � G y y U I C C_ m <L U ' N > m EE E . 9 r� 3 >cc `��i O acc N N a i O y x O d to Zt Cl - 8 O x v� � 3 W d � 3 iJ N a0 80 vm ai rn a p1 E x C d c a u i `c O w E U y n C C p Cy L y Q d O O Q p E N 3 IV m '" E a y E ` O �L N O C O � Y � d M N na 0 L 4) C 0 CL 0 m c CCO c a U (p `- L y d a OJTG $ O U CL j C� L . y Y L d OC O O _ d O C c S ydE'm .L.. N O y 3 U rn c O 3^ y LL U 0 � m U O N L CU V d C � CD ;cp N G U) O W 0 a m 3 E 5366 Godding Hollow Pkwy EARTH ENERGY ENVIRONMENT (E3) Longmont, CO 80504 Local: 303.902-5851 Industrial Hygiene and Environmental Engineering September 7, 2017 Mr. Ivan Garcia Mile High Environmental Services Inc. 9520 E Jewell Avenue Suite C. Denver, Colorado 80247 Subject: Clearance Report Residential Property 3090 Reed Street Wheat Ridge, CO 80033 Dear Mr. Garcia: Following is the project completion report for the work area located at 3090 Reed Street in Wheat Ridge, CO 80033. The purpose of this report is to document this remediation project was successfully completed, and indoor asbestos amplification was not occurring in the work area. An Industrial Hygienist for Earth Energy Environment (E3) performed the remediation project completion inspection and testing procedures. The remediation work area (Interior Area) was visually inspected in order to confirm the scope of work was properly followed and completed. The containments were also visually inspected to verify breaches and/or defects were not present. Phase Contrast Microscopy (PCM) samples were collected in accordance with the National Institute for Occupational Safety and Health (NIOSH) method 7400 using cassettes (standard 3 piece, 25 mm dia., 0.8 um MCE filter) purchased from Zefon International, Inc. The asbestos concentrations in the containment were calculated as airborne fibers per cubic centimeter of air (F/cc). Table 1 provides a summary of the sample numbers, sample volumes, and calculated concentrations. The National Emission Standards for Hazardous Air Pollutants (NESHAP) clearance standard is 0.01 F/cc. Visual inspection confirmed that no asbestos -containing debris was observed in the work areas. The PCM clearance air sample results were all below the NESHAP clearance standard of 0.01 F/cc. Based on the information presented above, E3 concludes the asbestos abatement in the work area has been successfully completed, and the work area may be reoccupied after build back. PCM Air Clearance Page 2 of 2 TABLE 1: PCM CLEARANCE AIR SAMPLING RESULTS Date Unit/ Area Sample # Sample Description Sample Volume *Fibers/cc Air Clearance CL -090617-1 1050 0.001 at: CL -090617-2 Inside 1045 0.001 3090 Reed Street CL -090617-3 Containment 1025 0.001 September 6, in Wheat Ridge, CL -090617-4 1030 0.001 2017 CO 80033 CL -090617-5 1020 0.001 (Interior Area) - BLK-1 Blanks - BRL BLK-2 BRL *BRL denotes "Below Reporting Limits". The PCM Colorado Department of Public Health and Environment (CDPHE) clearance standard is 0.01 F/cc. Thank you for allowing E3 the opportunity to provide environmental services to you. If you have questions or require additional information, do not hesitate to contact me directly at (303) 902-5851. Sincerely, Eli Willden Certified Air Monitoring Specialist No. 20139 5366 Godding Hollow Parkway ont, CO 80504 EARTH ENERGY ENVIRONMENT (E3) Lo Local: 303.478-0922 303.4778 0922 Industrial Hygiene and Environmental Engineering August 11, 2017 Mr. Jeff Wood Property Representative 3090 Reed Street, Wheat Ridge, CO Subject: Asbestos Sampling Results — 3090 Reed Street, Wheat Ridge, CO Dear Jeff: On August 9 2017, an Industrial Hygienist with Earth Energy Environment (E3) performed an inspection and asbestos sampling on a residential property located at 3090 Reed Street, Wheat Ridge, CO. E3 was retained by a property representative to determine if the accessible building materials within the property contain asbestos. SURVEY METHODOLOGY An industrial hygienist from E3 conducted the sampling. Materials were grouped into homogeneous sampling areas based on the material type. Among the interior building materials, fourteen (14) distinct homogeneous areas throughout the property were identified and sampled. Homogeneous Material Classifications ■ A preliminary walk through of the buildings was conducted to determine areas of materials which were visually similar in color, texture, general appearance, and which appeared to have been installed at the same time. Such materials have been termed "homogeneous materials" by the EPA. During this walk through, the approximate locations of these homogeneous materials were noted. ■ Following the EPA inspection protocol, each identified suspect homogeneous material was placed in one of the following EPA classifications: o Surfacing Materials - Sprayed or troweled on surfaces (walls, ceilings, structural members) for acoustical, decorative, or fireproofing purposes. This includes plaster and fireproofing insulation. o Miscellaneous Materials - Other non -friable products and materials such as floor tile and ceiling tile. o Thermal System Insulation - Insulation used to inhibit heat transfer or prevent condensation on pipes, boilers, tanks, ducts, and various other components of hot and cold water systems and heating, ventilation, and air conditioning (VAC.) systems. This includes pipe lagging, pipe wrap, block, batt, blanket insulation, cements, muds, gaskets and ropes. (These materials were not sampled as part of the survey.) 21Pog,_ Friability Classifications Friable and non -friable ACM's are defined as follows: ■ Friable asbestos -containing material: any material containing more than 1% asbestos, determined using PLM analysis, that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. ■ Category I nonfriable asbestos -containing material: asbestos -containing resilient floor covering, mastic or asphalt roofing product containing more than 1% asbestos as determined using PLM. ■ Category II nonfriable asbestos -containing material: any material, excluding Category I non -friable ACM, containing more than I% asbestos as determined using PLM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. ■ Regulated asbestos -containing material (RACM): (1) friable ACM, (2) Category I nonfriable ACM That has become friable, (3) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (4) Category 11 nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the materials in the course of demolition or renovation operations. Sampling and Laboratory Anal Bulk samples were collected by using various sampling tools (cutting tools, knives and chisels) to cut away or scrape portions of suspect building materials into zip -sealed plastic bags or sampling tubes. The individual samples were labeled by material type and location. Samples were analyzed by Reservoirs Environmental Laboratory located in Denver, CO. The laboratory maintains accreditations through the American Industrial Hygiene Association (AIHA), and National Voluntary Laboratory Accreditation Program (NVLAP). The analysis performed was EPA Method 600/R-93/116. INSPECTION RESULTS E3 collected at least the minimum number of samples from each homogeneous area necessary to meet all regulatory requirements for the quantity of material to be observed. Table 1 provides a summary of the homogenous areas. 3 1 P Table 1. Homogeneous and Functional Sampling Areas. Material Material Physical Classification Samples HA Type Description Description Collected 1 Attic Debris Insulation A Black debris Thermal System 3 Insulation Insulation 2 Floor Debris Demolition A Off white/multi-colored debris Surfacing 3 Debris on Floors Materials A Brown gold/black resinous 3 Bathroom Walls material Surfacing 3 Walls B Off white granular plaster Materials C White plaster A Tan resinous material 4 Kitchen Walls B White plaster w/ beige/multi- Thermal System 3 Walls colored paint Insulation C Off white granular plaster A White plaster w/ pink paint Surfacing 5 Stair Walls Walls B Light pink granular plaster Materials 3 C White/tan drywall Light Green A White plaster w/ light green 6 Walls and Walls and paint Surfacing 5 Ceilings Ceilings B White/tan drywall Materials C Light pink granular plaster Back A White texture w/ pink paint B Surfacing 7 Bedroom Walls White plaster w/ pink paint Materials 3 Walls C Light pink granular plaster A White/pink flooring w/ white 8 Bathroom Vinyl Floors fibrous backing material Surfacing 3 Floors B Pink flooring w/ black felt Materials backing material Kitchen 9 Floor Vinyl Floors A Green/multi-colored flooring Surfacing 3 (Layer 1) Materials 10 Ceiling Tiles 1 foot x 1 feet A Brown/white ceiling tile Surfacing 3 ceiling tiles Materials A Tan adhesive Basement 9 inch by 9 inch B Gray granular cementitious Surfacing 11 9x9 tiles floor tiles material C Off white/multi- Materials 3 colored sheet vinyl A Black adhesive 12 Kit Floor Vinyl Flooring B Off white/multi-colored sheet Surfacing 3 (Layer 2) vinyl w/ black fibrous backing Materials material A Brown adhesive 13 Kit Floor Vinyl Flooring B Off white sheet vinyl w/ gray Surfacing 3 (Layer 3) fibrous backing material Materials 14 Duct Wrap A Tan fibrous material Miscellaneous 3 Materials 41 r= u The laboratory separated and analyzed individual layers within each sample, if present. According to the laboratory analysis of the materials sampled, asbestos was detected in bathroom within the flooring and brown resin on the walls. The duct wrap was not sampled, but is assumed to be asbestos containing. Table 2. Asbestos Containing Materials HA Material Type Material Physical Asbestos Description Description Content Bathroom A Brown gold/black resinous material 15% 3 Walls Glue/Resin B Off white granular plaster Chrysotile C White plaster Bathroom Vinyl A White/pink flooring w/ white fibrous 25% 8 Floors Flooring backing material Chrysotile B Pink flooring w/ black felt backing material 13 Duct Wrap Insulating/ Sealant Wrap A Tan fibrous material Assumed Chrysotile Bathroom Black/Gold Resin Bathroom Flooring Duct Wrap 51Prr r� CONCLUSIONS AND RECOMMENDATIONS According to the laboratory analysis of the interior building samples, asbestos was detected in the bathroom flooring and wall resin. The duct wrap was not sampled, but is assumed to be asbestos containing. A portion of the flooring (12 square feet) and the bathroom wall resin (15 square feet) were disturbed by the remodeling activities. The bathroom is therefore considered a minor spill area. Visual inspect indicates the spill is limited to within the bathroom. A minor spill response followed by remediation/removal of the asbestos containing materials by a Colorado Certified Abatement contractor is recommended. The Colorado Department of Public Health and the Environment requires any asbestos -containing material that is friable or will be made friable during demolition/renovation activities be removed prior to demolition or renovation. Any potential asbestos containing materials identified in the future or during demolition that were not sampled in this, or any other previous survey, should be tested for asbestos content or assumed to contain asbestos before being disturbed. If you have questions or require additional information, please contact me at (303) 478-0922. Sincerely, Art Willden Certified Building Inspector No. 20138 Attachment A Laboratory Report Reservoirs Environmental, Inc. Effective January 1, 2015 Reservoirs Environmental QA Manual T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc M REI LAB Reservoirs Environmental, Inc. August 10, 2017 Earth Energy and Environment Corp. 5366 Godding Hollow Pkwy Longmont CO 80504 Dear Customer, Subcontract Number: NA Laboratory Report: RES 386864-2 Project # / P.O. # None Given Project Description: 3090 Reed Street Wheatridge Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 386864-2 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, Jeanne Spencer President P: 303-964-1986 5801 Logan Street, Suite 100 Denver, CO 80216 1-866-RESI-ENV F: 303-477-4275 www.reilab.com Page 1 of 1 J V Z_ J `Q r Z W 2 Z NO I.L Z W N w W U) W w W H C j w Y LO CL L E LO O m m U t 5' C d O y a O) E -p Q C L N O _ Z O L C- W o E c E O to dT U) LO le OCL fA N 4f N C C d p p Co W5 W L C t H t�0 d 7 0! 7 O W w w Z M Q N Q C j w O LO CO L E LO 0 ° a m LO 0 0 a`).2-> 5' m E (n 0 O) m z 0 Of Q EI > V U d _ N O _ Z a- C- o E c E O a aO U) C W N C C O L a) a)m C a) [CUUUD�Fa-D C j w LO LO CO CO LO 0 0 0 0 LO LO 0 0 Oa N m m O O) m O) O O O (O CO O O Z LC LL Q E O O O C o LO N N LO O O O �' LO O �' O Z w o Q'' H H a) c QLL a E O U 16 2 e o o Cl M o C) loci o a LOO 0 = m m- Z Z Z Z Z Z Z Z Z Z T Z Z yam) 7 r = W O N w m N r, d Q c_ t U 7 Co c C) O 0 O o O O O o O 0 O N 00 O O LO Lf) (n a C (6 .0 U d a) D T Mn Cu E N a? 0 0 0 o a) Co ) CU)2 .� N O O O E _O _ d f6 a) O_ O U O 77 V 7 @ y N n 7 7 7 C 2 C LO C C L (0 � E d E E o N 0) Co N min O O O Q � O. L L L L L L C L >> m m m > Co > J Q W w Q Q Q Q Q Q Q Co Q Co Q m U M It U') (0 r 0O m O M M m M M M M It y CSO Co (nO ((O C(O ((O ((O C.0 (00 E (A Q) O a) O) O d) O O 7 T T T T T T T T J W W W W W W W W W N M N ch to N L ; N M U U N N N U) D, E E U U U OO O L L L Co U fn Z Q Q Q LL E EL m m Z O W U y m LU .� w J 5 n CL y{ }7 d Z_ � Q � Z W M 2 O � > Z W cn w U � LU U) LU w 2 2 \ u IL 5 z w m � {a )\ $a0 Q$E oa& 0 < /J\ zee 0 � L \ $ . CL 3 k 0 a /E z 0 Q � $ G ° / EE E \.;--U)0 $ § \ o = = 5 $ c �000cle2 � M co 2 4 o § C-4 M C14 co c 2 2 §& C-0 co 8; ow- M 2 2 2 § M§ $° g a= 3 e o e� w w z n< w C4< 0 0 0 0 L \ $ % 0 k -0b , g a /E z 0 k 2 « / $ z * 7 = ® a EE \.;--U)0 $ U)\I E = = 5 $ c �000cle2 § 2 0 0 0 0 0 0 0 00 0 0 o r } g 0 0 0 0 0 0 0 0 0 0 0 0= 2 ƒC� E 0 m 3 COW ow- c o of o 0 0 ofU') ƒm e e}§§Eƒ/ e e� E / Ea?oon Ina c0000coo _ m .© z z z z z z z z z z z z z 41 I$ k w Q........... ■ 2 ■ ■ � 2 & .0} LOU') o r LO\/ 0 0 0 LO r o �CIJ rCIJ r- COLO r CN n# k \ 7 a/ ( o \ \ CL k /$ E m k\ k T .2 \ }£ @ k cl k \ t{ 2 k 2) s /% � k%_ a _ = a \ E - - , E R e , R C E c$ 5 R ƒ §/§ k e§ t e m W 0/ 0) 2�/\ 0) CL $ / f 7= C k. L\ a R J Eater §at $ak2 e¥ 0 4 R e o\ 2 = 4 =<»EOf<=O<=<=0<=<=0 k C.0 \ \ \ \ § \ \ \ \ \ \ g w w w w w 9 9 \ % 2 £ 2 2 \ \ \ \ \ E E \ \ \ b2z 2 7 2 « « \\ A U Z J `Q r Z CW G NZ I.I. Z W U) O W N W w m m .Q S d E E 00 .5;.5 W W PL, 0 0 h y C j .�-• Y C a O N a) O M 4L CD U � Q � O d a z O N E O O EE m ti a c ° o co � � � N a)L.. C � o H 0 c s r co LU 5 ` J O � w � E N d � `O _O W C> dO O co W 0:N N Z cn t'0 d 0 m C) 0 7 Im E w W Z M Q W N Q C j .�-• 0 0 C OCD O N a) � fl > N T CD C z 0 Q E � U o r 0 0 z O N -0 a O O EE m ti a o ao ( 0 o co � � � N a)L.. C � w U U U 0 H 0 C j .�-• 0 0 0 0 OCD 0 0 0 0 O O m O 8-6 o r 0 0 � M .. m - z m ti a O :3 N L C LL Q m o 5 ` J O J � E N `O _O O Eu 0) m E C 7 O O 1 w \° �' O O Q' 0 0 0 0 0 0 0 0 Zto0a) ~ ~ m rn a)r- O w d -0 - O Q E a C a) CE C Q 5D O T w N m C vn U m r a M M 0 0 w MM � d ii Z Z Z Z Z Z Z Z Z Z Z Z f3 O W N O yr N d LO cn O O O O cn Ln LO Ln O O In d � V) V) M S O M (O CO N CO C O C C U U) .Q T Ua C cu O c6 a c 'co a c ca o a a> a c6 a a) co L 3 a Y a a L a L m o 3 m .a� cm 0) .0 c 3 3 c a 3 3 c 3 c 3 a) (2 cu m c` W v5 -cz 0 Y N a3 Y C ca Y N O ca z a s •� a a a a a� a N a Q L L L>L> L> L J' J' J' J' co J > > JJ' > > > > (n J Q Q m Q m Q m Q m Q m Q m f� 00 O O N M N (0 (D � � � (o to m E _ rn rn _ rn _ rn _ rn _ rn _ rn J W W W W W W W N M M U_ U U fn C C C L d co a) C C C CL .0 U U U aoi (D ao) d E E _ 3N U cn Z U) (n fn U) J J J Z O W O (n m m N O U m O 8-6 o r 0 0 � M .. m - � m ti a O :3 N N m o 5 ` J O J � CL N `O _O a) Eu 0) m E C 7 O U m rn O O w d C a) CE C Q 5D U) T w N m C vn Q m r a M M 0 0 w MM � d ii U 2 � � 2 W 2 2 O > 2 W U) w O � W Cl) W w w m � §§ a \ 0 0 0 CL % 0 0§ 2/c o % % u � © E o E ' ■ .0 < \ k k } / U) e E § E --) w e $ 2/c�k(D o r± k Wa> 3 3 a 5§_ § m22£= C14e �e 2 0 $ ° a o= I= m w z m< w C4< E §§ a \ 0 0 0 o r 0 -� 0 0§ 2/c o w o % % 0 0 0 Q) Ea) o z k Of .0 < \ k k k\ e E § E --) (n \ Co e $ V) C: o r± o o Of w f W000c=ec 3 3 a 5§_ z7§/� §§ a or 0 0 0 0 o r 0 0 0 0 0 0§ 2/c o w o o w 0 o= 0 0 0 0 CLE / §§ n a'o o r± o o Of o r W 0 0 0 z7§/� �R C14e �e \ƒE E / �?Qoc000000000 kka-zzzzzzzzzzzz ..f.. § § � � 2 2 \} g 8\ R S\? S 2@ g o \� \ L \ 2 7 7 m 7 t 9 9 b } c q 0) 5ff± _ _% _ _ __ % _ _ m ± £ } $ 6 / \ ®\ \ a 2 $ \ / kƒ& kƒ= kƒ k& 0) q c�q c� q c� # m om m3®±3GOL3g0-a \/f -<y±W-<=o<=o<Eo<Io \ U') U') \ � \ @ w w w w \ \ 0 # r = 0 \ \ \ k © E E E I w E E / / G 2 z 2 u = m e \\ O {O T co O N 0 O L) a W J a J z =a E 0 0 C > W W 9 2 2 CD M d '75 y o W y mQ N :to,) O No E V C V U O m Q oaf Z �- O Y L E . a o O m E V o U � Q E U U N O y c. Z E 0 o E E ct ° co W .a) a) a)@ `O O C W V (p N OM) N C � d 0 C2 M W O 0 to COO H to c M Q O 01 LU w W z M Q W N Q O L E . o .� > i E V o LOO Z m Q E U U N O Z 0 o E E ° a o to ° co W .a) a) a)@ c O Q'UUUC]�Hm CO LOO C O O O O O O O O O Z� a E O U O O O •� 0 0 0 0 U LO O O O LO O Z co rn N C L O Q E O_ E O U W) p N 0 0 0 0 0 i y z z z z z Z z z z z w i r+ 0 O W N O d N c_ s � U o O O c to Ln C) 0 co N O O O O O O O O O O U) 0- q Lf) O 'IT LO M a) m E C � C Y U � N N U 7L a)O T C 15 > L N O O O O) O .• L C C C Em co Q O O O N N .a `m fl U U a) m m c`a m O 3 c c 3 c `o 3 Q Q O 0 O 0 O 0 :U :U � f6 @� O O •O -p U U U "I O) O. Q C Q C Q C N C N C O C C LO O L> L C O O N O O > > J J > 3: O_ Z Z c0 m J Q} W of Q co Q co Q m Q Q Q Q Q 00 O) O N M'CT LO (fl t -- LO U') co O CO CO CO (O O CO O O W 0 0 0 0 0 0 d) J_ W W W W W W W W W W N M O O (6 (9 `0 0 U U N > > N M N N L -O O O O N M F- F- y ., a� m co U- U- U- o o oo m 0) L L L L,L E E= U (n Z m m m m m Y Y Y U U Z o W <? N m i .T OPO J 6 Z J Z Cua G Z O Z W C0 O W N W w W J m H Cj Y 0 0 0 CL 7 0 LO O m L) O t- > N � C 0 O y d C E Vt Q c o U U _N h _O Z a 0 O_ c v) c w U)Q ''E vI U)� c q?T to E m v U e C Cn N cn N two C> N 0 8 O M W w U) O O O Ld tCDU) O 7 0 3 �: C 6n M Q m LU M W Z M Q W N Q Cj O 0 0 0 0 0 c . 0 LO O In O N O O O O t- > N � O N E N C Z 0 Q EN O U U _N h _O Z OEF O O. O_ Q E c 0 U)Q ''E vI U)� c q?T c c 2 E U Cj t!7 0 0 0 0 0 0 0 0 LO O In OO N c Z O O O O O O O O N O N-0 C LL Q E O U O O U) C o LO O O O O O 0 0 0 LO O LO Z U)O O W ti O C Wa E O U Z Z Z Z Z Z Z Z Z Z Z Z y£- °' > ) 0W O N O W d � Q 7 w c O N N N N U) O 7 � O O -0 .0 w U U U Q C C C C C E > > > > > d N N N o N N N cn N .�--'O 'O "O 'O "O — C O 2 N O N EO O O O O O O U O CC V m N N .O N E E E E co L C fA r !n E L 3 [2 •- m o, O oCo 3 �' 3 3@ 3 c c c m m` F -0O mco HO H mO-0 O-0 -jQ}wOf Q Q m U Q m Q m Q m Q m 00 O O N M to O E O) O) O 61 O d) J w w w w w w M C) m 0) C) m N c c c N N C Qa 0) E E E O O m7 O NN w m m m V lq Z U m m m Y Y Z O w Y N m w .2 m O d LL J U Z J LQ r Z W Z Z W UNN I.I. W N W w It r O -11 c . Q 7 0 0 O m E uvi ami U � Q aa) O m a Z c a E a 3 E -0 d d fn cc `O .-� 0 O (n R O N E a) W O o U U U 0 2 0 U l' 0 C N N Cl C) N d �(O C > d 0 O co W N ` N L w a1 CD 7 Coa o 7 3 N C O s CD = w W Z M Q W N Q O 00 c . 0 L 00 0 0 41 Q > N > E uvi ami c -0 Z Q E � U U a) 41 Z c a Q O O E 3 E -0 d d fn cc `O .-� 0 O (n W m aci (D E a) O o U U U 0 2 0 c� 00 0 0 L 00 0 0 O Cl) Cn O Cl) O V' Z � C i� a E O U c in O O j c o O O O C C) C) Z O LO N C QE a O U 0 Z Z Z 2 Z 2 Z o? N E ♦+ i 0W O N O N .NQ d eco o v� o �n� �� U)d FD a) rn O m c c E U U L) U Lt O he U � � O O O 3 v, C O a) a) U a C -0 7 7 3 3 3 Oc_ C � � C_ U f6 > (D > co C > N .N y 30 N '�w .) E E rn c- N.0 co o -L- 0 a> co L C L C t L L o 3Y 3 3 3 3 3 10 6- m Fn O J Q W w Q m Q Q m Q m LO CD I - y ((DD (DD (DD (DD m E _ rn rn _ rn rn 7 J W W W W Cl) - N M CV Cl) M M d y O O O O +' Q, O O O O y E E Uf%Z Y Y Y Y c m E z co c c c Q m Z o W q LU <n m KPI, a LL Earth Energy Environment (E ) PAY APPLICATION Services For: Jeff Wood Property Representative 3090 Reed Street, Wheat Ridge, CO INVOICE NUMBER AUG.11.2017- Reed INVOICE DATE Aug 11, 2017 PROPOSAL NUMBER Verbal PURCHASE ORDER NUMBER NA TERMS 130 Days Item Work Description Rate Total AMOUNT 1.0 Services at 3090 Reed Street, Wheat Ridge, CO Wednesday, August 9 2017 - PLM Sampling Labor and Reporting) FIXED $ 1,200.00 $1,200 DIRECT ALL INQUIRIES TO: MAKE ALL CHECKS PAYABLE TO: PAY THIS AMOUNT $1,200 cLI( c.L-UaN.COM tartn energy environment ATTN: ACCOUNTS RECEIVABLE PO BOX #348 FREDERICK, CO 80530 THANK YOU FOR YOUR BUSINESS! F�r L Ptd LPC r 4- 4.o=-Utl ' LGA .: 6i�`i F, Lo it a b y� f A = pical ACE �. (��(� _C) L—o t4)r )L-e- D 7`b installation l o P L E t-r LAP, f t 12 iI AL?I? A bo it r ,�! �'% '•-�` � [ ! + � t$ � �I A Li is ' � � S�-i �--! f r- ?� G 1--� � .��ia�' t,, }'`�t�' 4zk C-le E l S 'OD i S' LvA€Cr Citi S Ai t`.�Lb t'X�LL S 5 �' 17 -4tl Oer, THA Cecil Rickstrew, P.E. 1627 Glen Moor Dr. Lakewood, Colorado 80215 To: Jeff Wood EM: jeffwoodwoodwork@gmaii.com Invoice Phone #: 303-668-2382 E-mail: Cecil@ecsidenver.com Date: 7-16-17 invoice: 300-17 For engineering services on 3090 Reed St., Wheat Ridge 4 hrs. engineer's time @ $85/hr for inspection trip, inspection and stamped report .` .J= - This bill is rendered only as an accommodation. Terms are net cash and payable upon oresentation of invoice. Unpaid invoices accrue interest at 1% calculated on a daily basis. Please write the invoice # on your check or send a copy of the invoice with your payment 50 bs 5 `% 7. `1 2 �. Invoice Cecil Rickstrew, P.E. 1627 Glen Moor Dr. Lakewood, Colorado 80215 To: Jeff Wood LIM: jeffwoodwoodwork@gmaii.com For engineering services on 3090 Reed St. Phone #: 303-668-2382 E-mail: Cecil@ecsidenver.corm Date: 7-23-17 Invoice: 311-17 Revised beam location between kitchen and living room No charge Reframing of two bedrooms flush beams above ceiling 2 hrs @ S85/hr S i-7:; This bill is rendered onlv as an accommodation. Terms are net cash and pavame uc:€ presentation of invoice. Unpaid invoices accrue interest at 1% calculated on a daily oasi.> Please write the invoice # on your check or send a copy of the invoice with your payment Cecil Rickstrew, P.E. 1627 Glen Moor Dr. Lakewood, CO 80215 July 23, 2017 Jeff Woods EM: jeffwoodwoodwork@gmail.com RE: 3090 Reed St., Wheat Riage ie% Ph #: 303-668-2382 E-mail: Cecil Pecsicienver.cort This letter shall serve as this engineer's field inspection report of 7-19-17 with respect tc-1-h above referenced home. The inspection revealed the new drop beam proposed between the kitchen and living room for removal of the existing wall was not over the bearing wall below as detailed in my original report, out the wall previously beared upon the floor joist. Due to such, the drop bearn needs to be shifter 3' to east and a column of two 2x5 provided on the north side of _he stair well as shown in the attached elevation Secondly. the wall between the two bedrooms which is to be removed and [)resent! , is tc be replaced with flush beams mounted in the ceiling are shown on the attached Waage wit) tJhe- required additional support for such in the existing floor below. Undertaking the modifications as referenced above will leave the home structura iv sound it the area of modifications. Cecil Rickstrew, P.E. LPC Typic3i ACE iastailation IT L T L it L LO— �� T 3 L r-4 A-L�- L.4� 0 L-li L :,, I-- ; p �l 5W A -s --S VAd L -&c- � ve 7-6 VAT -)at -4 . .......... LPC Typic3i ACE iastailation IT L T L it L LO— �� T 3 L r-4 A-L�- L.4� 0 L-li L :,, I-- ; p �l 5W A -s --S VAd L -&c- � ve 7-6 VAT -)at -4 L "Li & CI>Mtkky :rpt ;'AL)�,Isfi '�vxlr, yOrrc -m '*,rjr'?. IOATI "V c 14t in i--47z�k r A V�- k VqW4*j&MW, *000 tf*"Xft TMA'T ""S V& "ft "Uf S"r TRW U*t$*^ " $00" 4KWDtW MAT INS" Ak" OM 1 0 "AAT "Wft 00 PAS"W& ~ 40 W*". M*CA4: *A "OrAn &C#ftS x 4 P"WUS, " OP *Jff BNWMW'f WrOO"T VS *AVW 00 MW VINNO AM MAI "Oft &II ft* $"WTW" OCA M 10* W& 0''**" M, 000" A& )NOWAIM 00 "M ou'r. "m owes is *Oft mt "04 A"" Ir*no low"" o"T 0.40 No ;"Mx "~ ASNOW I �✓ l o �u.'� Srr�7 City of Wheat Ridge e5y-e-45 t.J ; NiQP w� 2'sX'311i APPROVED.- BY: PPROVElie BY: It mir (- COMMENTS: AA*-- r Rolf" '1379`5e.n^e, N -7 ♦%�4�( Gry of ]OrWheatR MMUNITY DMtjorWNT APPROVED Reviewed for Code Compliance 0� Plans Examiner Date The Issuance Of o permit a approval of Plans spec fKd'" VndComp a^—^ violation to acrd computations shoU not be o permit for• 010" approval �anV ��� any of the provisions of the buildup code "'Of arty Gly ord presuming to give outhorily to notate of cancel the provisions of the codes or other ordinances of the City shop not be valid. 5ress $A%Ale IT NOT APPROVED AS AN INDEPENDENT DWELLING UNIT, �P.LD S--/ 3.7 1 5 o vi ae Re 177 OP I le- 1) PJ J) R (A )V t) W 151 1-) L7 D -pr 1) PJ J) R (A )V t) W 151 1-) L7 O�c z k I city or , what Ridge 8L47 F/11 (, X-C —r --O C c, p e - S; Ib Vent KvR-, W4u,s q, s Q PPC r P 1001- f It 40-e , OQ1- %Ie40-e, Rehoujlf- City of Wheat Ridge Disijgnr, i CITY OF WHEAT RIDGE - Builtimrg inspection°13iriision (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 3 a 9 D R 61 16, dS' �- Permit Number: a C 1-7 0 S 1 S(o ❑ No one available for inspection: Time AMM Re -Inspection required: Yes CNo When corrections have been made, call for re -inspection at 303-234-5933 Date:3 s �/S Inspector: i DO NOT REMOVE THIS NOTICE .,�d � !til tt� City of '` Wheat Ridge -00A" MUNITY DEVELOPMENT City of Wheat Ridge Municipal Building February 22, 2018 Woodwork Real Estate, LLC Mr. Jeff Wood 3090 Reed Street Wheat Ridge, CO 80033 7500 W. 29" Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 RE: 201708456 Single Family Dwelling Interior Remodel at 3090 Reed Street Dear Mr. Wood, I am writing this letter to inform you that your General Contractor Derek Thiess, of The Mystinfield Group, LLC, has recused himself from the above permit as the General Contractor. As a result, your project officially does not have a General Contractor listed on the permit, and we are therefore suspending all work and all inspections on your project until you are able to obtain a new General Contractor and add him/her to the permit. Consequently, we will be posting the project site with a Stop Work Order until a new General Contractor is listed on your permit. To continue working and before we can let work resume under this permit please select a new General Contractor and have him/her or his/her representative come to the Building Division Counter below and add their company to the permit. Your new General Contractor needs to provide insurance information and be licensed in the City of Wheat Ridge. Should you have any questions regarding this matter please feel free to give me a call. Respectfully, Kenneth Johnstone Interim Building Official and Community Development Director 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2844 Fax: 303-237-8929 www.ci.wheatridge.co.us City of W heat Ridge COMMNIT UY DEVELOPMENT E+°wN,.ci.svheatridge.co.us C9 i CITY OF WHEAT RIDGE Eluitding Inspection' Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 309- LsDo- ___rnSUj4bCL, Job Address: 3 o g 0 L e e S4 Permit Number: -a a 1 7 U'9 '-1 S-6, 1 !l JJ� )''G -Col �' c C i G �l cO�JC� D UP5g, r 5' �tn5 �t" C e A U- ❑ No one available for inspection: Time 1; - -D 7 AM PM Re -Inspection required: Yes Q When corrections have been made, call for re -inspection at 303-234-5933 Date: a i /IS Inspector: `TLS DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE _1�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 2-Di)C— Job Address: 301� o V2EED 5`r Permit Number: 2_g:,t'i O 0 06—ky-"c " E-(�> 1-P Scam° p \ Cl 3c,>3-735 - 2135'2 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: Ll 7-1 i$ Inspector: r 0 DO NOT REMOVE THIS NOTICE M i CITY OF WHEAT RIDGE Building-InspectioYa Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE r _ f PC VC !1 r=n S Inspection Type: "� !3 13 / oS -'� �aA1, c�l�n►�, "Job Address: -73 v R o Re, �-�- Permit Number: 0l -a o 43 y S ❑ No one available for inspection: Time I = -K-,;7-AM/PM Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: '?'7\-) DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 30qO X_ -S70'- Permit Number: cW 70` -5 l ❑ No one available for inspection: Time Re -Inspection require< Yes Ao When corrections have been made, call for re -inspection at 303-234-5933 Date:' q" �Cj Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Remodel PERMIT - 201708456 PERMIT NO: 201708456 ISSUED: 12/01/2017 JOB ADDRESS: 3090 Reed ST EXPIRES: 12/01/2018 JOB DESCRIPTION: Remove load bearing wall to create Master Suit and Bathroom; basement remodel; add 2 egress windows in downstairs bedroom; asbestos abatement in upstairs bathroom; 1,100 sq ft **REVISION**Adding closets to down stairs bedrooms (labeled #3 & #4 on plans) both closets are 3x5 feet along north wall; Added valuation: $36.00 *** CONTACTS *** OWNER (303)618-5358 WOODWORK REALTY -JEFF GC (720)421-8174 Derek Thiess SUB (303)909-7355 Robert Joseph Magee SUB (720)275-8725 Richard Collins 120023 The Mystinfield Group, LLC 110130 Grateful Electric 100264 United Plumbing Services Co. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 40,000.00 FEES Total Valuation 0.00 Plan Review Fee 399.46 Use Tax 840.00 Permit Fee 614.55 Investigative Fees 614.55 ** TOTAL ** 2,468.56 *** COMMENTS *** *** CONDITIONS *** **PERMIT FEES DOUBLED FOR STOP WORK ORDER** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. Basement is NOT APPROVED AS AN INDEPENDENT DWELLING UNIT. **Certificate of Completion will not be issued until Public Works requirements are met for drainage** **REVISION**Adding closets to down stairs bedrooms (labeled #3 & #4 on plans) both closets are 3x5 feet along north wall; Added valuation: $36.00 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this,permit. I further attest ,diad am legally autho zed to include all entities named within this document as parties to the work to be performed and that all wok be performed is, sclosed in this document and/or its' accompanying approved plans and specifications. / 2 1-/� Signature of R or CONT CT61Z (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180.days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to I obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordlifance or regulation of this jurisdiction. Approval of work is subject to field inspection. SignaturCTi of Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge 40�771 Residential Remodel PERMIT - 201708456 PERMIT NO: 201708456 ISSUED: 12/01/2017 JOB ADDRESS: 3090 Reed ST EXPIRES: 12/01/2018 JOB DESCRIPTION: Remove load bearing wall to create Master Suit and Bathroom; basement remodel; add 2 egress windows in downstairs bedroom; asbestos abatement in upstairs bathroom; 1,100 sq ft **REVISION**Adding closets to down stairs bedrooms (labeled #3 & #4 on plans) both closets are 3x5 feet along north wall; Added valuation: $36.00 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this,permit. I further attest ,diad am legally autho zed to include all entities named within this document as parties to the work to be performed and that all wok be performed is, sclosed in this document and/or its' accompanying approved plans and specifications. / 2 1-/� Signature of R or CONT CT61Z (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180.days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to I obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordlifance or regulation of this jurisdiction. Approval of work is subject to field inspection. SignaturCTi of Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Midge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permitsCa)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: f 3/ Add to Permit # i( Doi 7DO56 Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. **" Property Address: Owner era/5�'�_ Phone: 36'- Property 6' Property Owner Email: 1,vor-1c /O Mailing Address: (if different than property address) Address: City, State, Zip: Submitting Company: Contact Person: �� FFF L,)0 ID Phone: 7:,,o3_ Contractor: Contractors City License #: Contractor E-mail Address: Phone: Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour — 2 hour minimum). Description of revised/amended work: C-,-/, C/05e-- Are W4 N Sq. Ft./LF Btu's 3 .-reel i r,-, Amps Squares Gallons Other Additional ect Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) CONTRACTOR) or(AUTHORIZED RE7ESE7N.ATIVE) of OWNER) (CONTRACTOR) i PRINT NAME: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENXCOM ENTS: Reviewer„ PUBLIC WORKS COMMENTS: Reviewer: SIGNATURE:. " %� DATE: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required Building Division Valuation: $ 90 ge�D S--/ -3.7 1 � a0170q5�, lokooll "DO \d 'C�dN 3-e Co,- --- pe ??T ap T -----i , 0 Q -c 1) P" 0 k (4 fJ 6 14 -1 -)1 )3 i CITY OF WHEAT RIDGE Building Inspection'Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 01 3 os - o 1/.9 Job Address: 3 o g n 6;� & cT S �- Permit Number: P O 1-7 o 9 o U C, h '4-f-ci n i g r\ LYl 5U n on AJ o4- DbR►tvV-C GC r -e d v le tb v D /V rrl �`r, a w Le ,) /`ecjv Gs Eve It. ❑ No one available for inspection: Time I 0 " 3 S,(P�M Re -Inspection required:es No When corrections have been made, call for re -inspection at 303 -234 - Date:— �0f a Ig Inspector: —T DO NOT REMOVE THIS NOTICE z i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE / K -3 O`i3 Inspection Type: ZQ 1 Job Address: S o G c c c ��- Permit Number: Q D 1-7- 0 I V Cj / E-7.�.s ' -f�y 4DK-J"'k ❑ No one available for inspection: Time '4,, 3 <3 A&PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE 11/20/2017 Kenneth Relyea Affordable Garages 177 W. Alameda Denver CO 80223 303-384-3242 RE: Permit # 201707245 3090 Reed St. Wheat Ridge, CO 80033 Sheathing Observation Detached Garage Job # 2017-4007 OL ENGINEERING. INC. �TI?IJf_T!_I:t�.L E:`t[;!^.c [tti^z, �-1i2,:�tF:== J••:."`.:_ rfi?7E1`:�ti' F_N+wirIEERI=`li 2750 S. WADSWORTH BLVD_SOITE 0-203 DIMER, CO 80227 720-440-9450 OLENGINEERZOM C-7 Please provide this letter as proof of the following onsite observation on November 14, 2017 at 1:50pm: • Roof Sheathing - I observed the installation of the roof sheathing, 19/32" OSB with a 40/20 span rating, for this project before the roofing was installed. If you should have any further questions, please feel free to contact me at (720) 440-9450 or dlemier@dlengineer.com. Sincerely, Daniel LeMier, PE � � 4 i CITY OF WHEAT RIDGE _1�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address:A� _S f Permit Number: �E'/70 %q5 ❑ No one available for inspection: Time A Re -Inspection required: Yes When corrections have been made, call for re -inspection pection/4 at 303-234-5933 Date: Z,?,15,%7 inspector: �� �— DO NOT REMOVE THIS NOTICE e,. City of Wheat Ridge Residential Electric PERMIT - 201709611 PERMIT NO: 201709611 ISSUED: 12/15/2017 JOB ADDRESS: 3090 Reed ST EXPIRES: 12/15/2018 JOB DESCRIPTION: Residential Electrical permit entire house being completely rewired and upgraded to code. *** CONTACTS *** OWNER (303)618-5358 WOODWORK REALTY -JEFF SUB (720)276-6045 Firdays Mirsoliev 170698 F and F Electric *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,500.00 FEES Total Valuation 0.00 Use Tax 157.50 Permit Fee 172.60 ** TOTAL ** 330.10 *** COMMENTS *** *** CONDITIONS *** Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection I, by mjItI signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicae building codes, and all applicable municipal codes, policies and procedures, and that I am t e legal owner or have been authorized by the lgal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this per. further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed inclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanyingplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable co�lg"-,any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official 9 Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ON of W heat ge COMMUNIIY DEVELOPMENT Building & Inspection Services Division 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permitsgci.wheatridge.co.us FOR OFFICE USE ONLY Date: /% Plan/Permit # C J Z Plan Review Fee:, �e ��;16?�/ Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: In yo Property Owner (please print): �� �l l�o0(� Phone: 30 --61&- Property 6/&- Property Owner Email: ,�� F i � �,J Cwt K"I" c-111.011,11 Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Contractor: E xtL E Elec I( e_ Contractors City License #: ( -1 C)% Cl f� Phone: 7 z - -z 7 U — 67ol/S Contractor E-mail Ad For Plan Review Questions & Comments (please print): CONTACT NAME (please print): rKa Phone: WC - q9S - CONTACT EMAIL(p/ease print):c� �L4, (L.Owu`.5 wick" k � cc) Sub Contractors: Electrical W.R. City License # Other City Licensed Sub: City License # City License # Plumbing: W.R. City License # Other City Licensed Sub: Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL 2-1' ESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ POMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT RLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Se�c�:e C, X rre ; �'t°VVI (0',t� ar+� ��J4c.c( F, yIt J zoc Sic-(JicC. 6aS-e fAe a 4 -FiH, k► , C-OVD7 P 1 r �c - W', t&-. er PaSfMFr•�- ) P u4I,- sea c - QQ P/`I- (cey-0 Sq. Ft./LF Amps N akn tl40 t , ac�& Cc,,4� Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER (CONTRACTOR) Signature (first and last name): �f. /iYa,,.•�' DATE: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: 1 DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION Building Division Valuation: $ .m 1 l , �+0 y1 s � � / E 1i�l 11V N 0 te ' city Cr =� WheatR�e CQMMUNM DMU"04T APPROVED Reviewed for Code eomali"� � S � plan; E.amiaer Daft rmR Tlr nsvonre of o permit a oppovd of plats speujwtoro Va1dMQt35- and computatmns shall not be a pemut Jor, "a" aPprawal 4 any violation to MW of the prow;sions o1 the buiMirp code a of on► City ordinances. Per'"Ns prcsumirq to give authority to violate of cancel the provisbns of the owwkq coda or other ordinances of the City sholi not be vend. 3090 04G',n 1r�el e c � �o{ �- Com V\A'�,A- \'(-'1e� (ev:Ae o1� N ,e �') Q � c, < < e 5 (U e ,- ) "31 -S — i 74 ((_ED) C=ite l cc, Ow t c C- 260,4 Jen a n 7�j o1 Vl'�c�c�c�v�^� C e C—` �aCoge- SC�qCG /-t'9' D-VwleiAt- c�J c rC tO MF�N'� �•�-S 9cV- .5 cvt v1ckCc LIJ l v; 41) ti! e .,.J (CA- v VIL& !y C i rC 4vu ZO tN e � p ece p A i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: .8F JobAddress: Permit Number: ®10/70 _7ay,5 I e 1")a itil«, /9 ❑ No one available for inspection: Time AM(M) Re -Inspection required: Yes (No-,-' When corrections have been made, call for re -inspection at 303-234-5933 Date: /o) • /.S- / 7 Inspector: � /4 �-- DO NOT REMOVE THIS NOTICE A r City of Wheat Ridge Res. Accessory Struc PERMIT - 201707245 PERMIT NO: 201707245 ISSUED: 11/03/2017 JOB ADDRESS: 3090 Reed ST EXPIRES: 11%03/2018 JOB DESCRIPTION: Residential Detached Garage 24X24ft. *** CONTACTS *** OWNER (303)618-5358 WOODWORK REALTY -JEFF SUB (303)384-3242 Ken Relyea 019461 Affordable Garages *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 19,350.00 FEES Total Valuation 0.00 Plan Review Fee 235.82 Use Tax 406.35 Permit Fee 362.80 ** TOTAL ** 1,004.97 *** COMMENTS *** ** CONDITIONS *** Work shall comply with 2012 IRC & 2014 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure.All roughs to be done at Framing Inspection. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. For one- or two-family dwellings, the first twenty-five feet (25') of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. A right-of-way permit may be required; contact Public Works Department at 303-235-2861. NOT APPROVED AS AN INDEPENDENT DWELLING UNIT. Landscaping removed or damaged during construction must be replaced prior to final inspection. City of Wheat Ridge Res. Accessory Struc PERMIT - 201707245 PERMIT NO: 201707245 ISSUED: JOB ADDRESS: 3090 Reed ST EXPIRES: JOB DESCRIPTION: Residential Detached Garage 24X24ft. 11/03/2017 11/03/2018 1, by in signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of th o erty and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermI - I furthe y)e x th awn legally authorized to include all entities named within this document as parties to the work -to be performed and a�!'wo}k to e pe?ormed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies andprocedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all re uired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issw mice or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Bu leo C, '" '"�"�"� Date REQUESTS NUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. � A City of eatEN�11�lild 40- �ommuNPTY DEvELoPT;MT4qg Building d Inspection Services Division 7500 W. 29"' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits@ci.wheatridge.co.us FOR O//��FFI/C�E ijJSE)O1�LY Dade: � 1 11"U , Y'O(W Plan 1?earlew Fee: Building Permit Application Pies" complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. Property Address: -30 A� Owner (please print): W000>' VVPr1(� '11 eah/i "�e4�— Phone: 3)&, --. Property Owner Email: Mailing Address: (ff different than property address) Address: City, State, Zip: Architect/Engineer E-mail: Contractors City License : Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: '03 -5V --5V Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this orim _ i s l ❑ COMMERCIAL ❑ RESIDENTIAL Descrigon of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. Ft./LF 5-76 °-N Btu's Amps Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) ! 3 so. OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that 1 am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) o„rU HO�RIgZ�/EI➢ R SENTATIVE) of (OWNER) (CONTRACTOR) 4� Electronic Signature (first and last name): I DATE: `" +? DEPARTMENT USE ONLY ZONING COMkIl&?4TS ? cj OCCUPANCY CLASSIFICATION,: Reviewer .r BUILDING DEPARTMENT COMMENTS: Reviewer Building Division Valuation: $ 7500 West 29th Avenue City of Wheat Ridge, Colorado 80033 303.235.2846 Fax: 303.235.2857 Wh6atl�JdLye Approval of Variance WHEREAS, an application for a variance was submitted for the property located at 3090 Reed Street referenced as Case No. WA -17-09 / Wood; and WHEREAS, City staff found basis for approval of the variance, relying on criteria listed in Section 26-115 of the Wheat Ridge Code of Laws and on information submitted in the case file; and WHEREAS, the Community Development Department has properly notified pursuant to Section 26-109 of the Wheat Ridge Code of Laws; and WHEREAS, there were no registered objections regarding the application; NOW THEREFORE, be it hereby resolved that a 12.5 -foot variance (50%) from the minimum side yard setback requirement of 25 feet for side yards which abut a public street on property zoned Residential -Two (Case No. WA -17-09 / Wood) is granted for the property located at 3090 Reed Street, based on the following findings of fact: I. The variance would not alter the essential character of the neighborhood. 2. The alleged hardship has not been created by any person presently having an interest in the property. 3. The request would not be detrimental to public welfare. 4. Existing conditions on the property present a particular and unique hardship. 5. No objections were received regarding the variance request during the public notification period. /11 I�a�e City of COMWheat �1 e MUNITY DE\�ELOPMEf�IT �' City of Wheat Ridge Municipal Building 7500 W. 29`h Ave. September 5, 2017 Jeff Wood 19483 E. Tufts Cir. Centennial, CO 80015 Re: Case No. WA -17-09 Dear Mr. Wood: Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 Please be advised that your request for a 12.5 -foot variance (50%) from the minimum side yard setback requirement of 25 feet for yards which abut a public street on property zoned Residential - Two (R-2) for the purpose of constructing a detached accessory structure on property located at 3090 Reed Street has been approved. Enclosed is a copy of the Approval of Variance. Please note that all variance requests automatically expire within 180 days (February 28, 2018) of the date it was granted unless a building permit for the variance has been obtained within such period of time. A permit has already been submitted for the detached garage; but ask that you bring, to the Planning Department, an amended site plan. Please feel free to be in touch with any further questions. Sincerely, Tammy Odean Administrative Assistant Enclosure: Approval of Variance Case Report Cc: WA -17-09 (case file) WA1709.doc NvNN «•.ci.-*N•heatridge.co.us RESIDENTIAL Building Permit — Plan Review Worksheet Address: 3 DC% O g4S&� �5f Zoning: Lot Size: '7 5'2 - Property Z Property in the flood plain? > J sq. ft. Lot Width: 1Z- Z Rev. 09/2017 If yes, notify PW Floodplain Administrator and add surveying condition FLD Subdivision: TAl--VI'�JRJN,- Any conflict? (Y/N) Related Cases: Type of project (applicable survey conditions in parenthesis): Maximum Lot Coverage: q0 % sq. ft. Existing Improvements (footprints): House: 3,9 sq. ft. Shed: sq. ft. Detached garage: sq ft. Other: sq. ft. Proposed Improvements (footprints): _4 0A S t ZE House/addition: ] U 3 S sq. ft. e ft_ �-► t S Shed: sq. ft Detached Garage: S-] (o sq. ft. +C�2o2� Other: sq. ft. r ?P7Rt7 Total Existing (U 35 sq. ft Proposed+Existing 22- < < sq. ft Lot Coverage kJ % Lot Coverage 2-3 % Required Setbacks: FR S 25� S S R 10 Provided Setbacks: FR S �Z..� S I C -p_ R For additions or new constrh9iUUoA, is the structure within 2 feet of minimum setbacks? If yes, add surveying condition FND. Maximum Height: ( - ft..�t,� Maximum Size: L(' o sq. ft. Proposed Height: \2. S �' _ ft• Proposed Size: sq. ft. Does the bulk plane apply? (Y/N) If yes, does it meet on all sides (Y/N): FR -- S S R (See 26-642 and 26-120.C.1 — applies to all single-family structures (new, addition, accessory) in R -IC and R-3) Parkland Conditions Does the permit result in a new dwelling unit (new structure or conversion from non -res use)? If yes, have parkland dedication fees already been paid (eg with a previous land use approval)? If fees are owed, add condition PFEE, notify owner, notify building division, enter fee amount in ADG. Rev. 09/2017 Streetscape Conditions Does the permit result in any of the following conditions? ❑ Construction of new roads ❑ Platting of new lots ❑ New development ❑ Additions that increase gross floor area (not just the footprint) by 60% or more (proposed floor area — existing floor area ) / existing floor area = % increase If any box above is checked... For SF/DUPLEX—Is there existing ❑ Curb ❑ Gutter L15 -ft+ sidewalk adjacent to the property? If curb, gutter or sidewalk is missing, streetscape construction or fees -in -lieu will be required. MULTIFAMILY—Does the frontage meet current city standards? If not, streetscape construction or fees -in -lieu will be required. Fees -in -lieu of dedication or construction are due at the time the permit is issued. Access Conditions (apply to all new driveways, garages, additions, or new homes/units) ❑ For one and two-family dwellings, the first 25' of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. ❑ For all uses other than one and two family dwellings, no vehicle entrances or exits may be closer than 25' to any property line, except when used as joint access for two or more lots. ❑ In residential zone districts, curb cuts shall be at least 10 feet and not more than 24 feet in width. ❑ One and two-family dwellings may have horseshoe driveways, provided that the street accesses are at least 30 feet apart, measured from the interior edges. ❑ For all uses, one access point per property is permitted. Landscaping Conditions (apply to additions and new dwelling units) ❑ For one -and two-family dwellings, one tree for every 70 feet of street frontage is required. Frontage of lot - width of driveway / 70 = (round up for required trees) Street trees required: Street trees provided: ❑ 100% of the front yard and 25% of the entire lot must be landscaped 'prior to issuance of C.O. ❑ In the event that landscaping cannot be installed due to inclement weather prior to the issuance of a C.O., an escrow agreement with financial guarantees may be allowed to ensure future installation. 125% of the cost of the proposed improvements will be required with the agreement. These funds will be reimbursed back to the property owner or contractor once the improvements are in place. Dwelling Unit ❑ Not approved as an independent dwelling unit. pe hIt A lN F. 0 0 -j yam R In 00 4 4L ib C) _q 0 L -0 C A, (b 0 1114 g� 45 Z , , IQ tY ATT Ab'_ ILI 4� City of �C(1ilNMUNITY DEVELOPMENT APPROVED RevieWed for Code Com Lk P10 -s ExwnWw w*s orwhffoa�Wam aloe OY~Mfbrwu JICI ar City of �C(1ilNMUNITY DEVELOPMENT APPROVED RevieWed for Code Com Lk P10 -s ExwnWw w*s orwhffoa�Wam aloe OY~Mfbrwu c0 Cj) C � n CD c 0 -*o a, CL O M 0 S e. CCD' CL 1! 0 M. Wr to ® O E �®.n O O C ID - ..a .=s OS QS to � � � � M C C Q CD M CL CL ®0 � M N 9 Cb C CD Y. gWD CD CD Pr CD CA to 8- Im _Im r .00 VI• �6 CD WW�c+d.c.. .� CD Cx CAI w Al c ' E m d 00 Ct` O 00m 0 0 o� O � Ca T• N C' C5 C co CD OL o o cn 8 OL Elio I5� M v 0 o M Cm. Vis N Q° m m �a i co CD .. . 03 I� 1D E ad o° oa-)b . 0 U - 98 omv%wl, w U)'W co -W co co �E o o� �0$ � N TCD Lo O C 2 Q CD T co o c mE - m aCte O Cx� a �. _ ® i� o o mo 13 acd a -O .- if Q LL Cid omv%wl, w U)'W co -W co co �E ' 1u8184 w .0 — 346104119m 111101-xuw .z 1 o� c d U m m . o c 0 _ 5.4 0N7 E A O U c V N O m O a U'a oU c c m o CA o OE -A U E C dgi� O O O - a-S�vVm W o o� �0$ � N TCD Lo O C 2 � T c mE m v, �. 0 ® i� O C a c � r s 0. 00 x =� N c N r8 O co C ' 1u8184 w .0 — 346104119m 111101-xuw .z 1 o� c d U m m . o c 0 _ 5.4 0N7 E A O U c V N O m O a U'a oU c c m o CA o OE -A U E C dgi� O O O - a-S�vVm W �-� O Iry C LA[9WWO� OSAOUddV OC CITY OF WHEAT RIDGE �`iuSP Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:/ //) Job Address: 7F. �eS�— Permit Number: 2017627(2,56 ❑ No one available for inspection: Time AMIPM ' Re -Inspection required: `Yes ,-No When corrections have been made, call for \\re -inspection at 303-234-5933 Date:2,s7,/7 Inspector: ®O NOT REMOVE THIS NOTICE M r City of Wheat Ridge r. J Residential Remodel PERMIT - 201708456 PERMIT NO: 201708456 ISSUED: 12/01/2017 JOB ADDRESS: 3090 Reed ST EXPIRES: 12/01/2018 JOB DESCRIPTION: Remove load bearing wall to create Master Suit and Bathroom; basement remodel; add 2 egress windows in downstairs bedroom; asbestos abatement in upstairs bathroom; 1,100 sq ft *** CONTACTS *** OWNER (303)618-5358 WOODWORK REALTY -JEFF GC (720)421-8174 Derek Thiess 120023 The Mystinfield Group, LLC SUB (303)909-7355 Robert Joseph Magee 110130 Grateful Electric SUB (720)275-8725 Richard Collins 100264 United Plumbing Services Co. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 40,000.00 FEES Total Valuation 0.00 Plan Review Fee 399.46 Use Tax 840.00 Permit Fee 614.55 Investigative Fees 614.55 ** TOTAL ** 2,468.56 *** COMMENTS *** *** CONDITIONS *** **PERMIT FEES DOUBLED FOR STOP WORK ORDER** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. Basement is NOT APPROVED AS AN INDEPENDENT DWELLING UNIT. **Certificate of Completion will not be issued until Public Works requirements are met for drainage** City of Wheat Ridge Residential Remodel PERMIT - 201708456 PERMIT NO: 201708456 ISSUED: 12/01/2017 JOB ADDRESS: 3090 Reed ST EXPIRES: 12/01/2018 JOB DESCRIPTION: Remove load bearing wall to create Master Suit and Bathroom; basement remodel; add 2 egress windows in downstairs bedroom; asbestos abatement in upstairs bathroom; 1,100 sq ft I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this pen -nit and perform the work described and approved in conjunction with this permit. I further attest that I am ally authorized to include all entities named within this document as parties to the work to be p rme d that all to b ormed is disclosed in this document and/or i ' accompanying approved plans and specifications. S ure of O R r ONTRACTO (Circle one) Date I . This permit was issued ed on ation provided in the permit application and accompanying plans and specifications and is subject to the compliance wit t ose documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpennit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new pen -nit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all re uired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit s . 11 not be c nstrued to be a permit for or an approval of, any violation of any provision of any applicable code or, a_ tsdii�4n e or r ati ` of is jurisdiction. Approval of work is subject to field inspection. .t 4 ,. . - � Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat�idge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(o)-ci.wheatridge.co.us j FOR OFFICE USE ONLY Date: Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. **" Property Address: �f� C_" Owner (please Property Owner Email: Mailing Address: (if different than property address) Address , State, Zip: W Architect/Engineer: Architect/Engineer E-mail: Contractor: Ph Phone: Contractors City License #: Phone: 7-e_"0r Contractor E-mail Address: Sub Contractors: ElectricalekA-L)Plumbing: u, C("4k TtLL (—Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: City License # Other City Licensed Sub: City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL `SIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and mmni int of mntprials to hp i mAd ptr,. 1 Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNSTRACTOR) or (RUTH ZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first add last name): DATE: L --"DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ ❑ COMMERCIAL X RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE '® ELECTRICAL SERVICE UPGRADE Qj NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION 19 WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ® PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ]C ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) 1 PrI�rNS �L.'1 Sti�cr-r �yAjl �,1P57Arr-s/ %aD9T'T � j.�rs5 :..c:�P,.;J�-•t 'S r.-. �::�r.-+env? t'rddr ii! t.� Project Value: (Contract value or the cost of all materials and labor included in the entire project) I S 7 L/ , CSC) C� OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER (CONTRACTOR) Ar (AITHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Z7-1/ i / Electronic Signature (first and Fast name): '7// DA'L'E: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer. BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ CCctc>s�SNtN1 g.4a.fv 74 13e�9Qro,n 11-7v /'Y7 A s '7 e..— ,,1., m A S -71-P' S !rt r -z Sq. Ft./LF / I' e o Btu's Gallons Amps Squares Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) I S 7 L/ , CSC) C� OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER (CONTRACTOR) Ar (AITHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Z7-1/ i / Electronic Signature (first and Fast name): '7// DA'L'E: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer. BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ Dk4wdens • Submit two complete sets of required information. • Draw a floor plan with dimensions drawn to scale, showing the layout of the entire basement. Label the use for all of the rooms. ' • Show electrical outlets, smoke a,, buns, carbon monoxide alarms, lighting, fans, plumbing modifications, cleanouts, fuma`ce, and water heater. List window sizes and types, identify emergency escape and rescue - windows, and egress window wells with ladder and clear dimensions of • window well. Basement Finish Reements 1. Cdbg He1ghts: If the finished ceiling will be less than 7', please consult your Building Department, 2. 6M"My BMW All basements and sleeping rooms must have an emergency escape window or exterior door. Emergency escape windows with a sill height below grade must be provided with an emergency escape window well and ladder. (For emergency escape window and window well requirements, see page 3.) S. eke Alam: Smoke alarms are required in all basements. If the finished basement contains a sleeping room, a smoke alarm must be installed on the ceiling or wall in the sleeping room and in the hallway or area immediately outside of the sleeping room. Smoke alarms added to satisfy the above requirements must be hard -wired with battery backup, and interconnected with existing smoke alarms. Smoke alarms are required to be hardwired and interconnected in new and existing bedrooms, halls and on each level unless removal of interior wall or ceiling finishes would be required. In this case, battery operated devices are acceptable. listed wireless alarms are acceptable. 4. CaMm Monoxide Ahem: Carbon Monoxide alarms are required on each floor with bedrooms. They are recommended to be located no farther than 15 ft. from any bedroom entrance. Do not install within 15 ft. of a fuel burning appliances. Follow manufacture's recommendations for location testing and replacement. fFuel s. maces and water heaters cannot be located in a bedroom or bathroom unless appliances are installed in a dedicated enclosure in which all combustion air is taken directly, from outdoors, and a weather stripped solid door equipped with an approved self closing device is installed. If the furnace and water heater are being enclosed, adequate combustion air must be provided for these appliances to operate property. For maintenance purposes, a minimum of 30 inches clear working space must be provided in front of furnaces and water heaters. Maintenance or removal of each appliance must be possible without removing the other or disturbing walls, piping, valves, ducts, vents, wiring or junction boxes. This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. it is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. 9/9/13 Identify modifications to the existing structure such as posts, beams and floor joists. Indicate height of dropped ceiling areas less than 7 feet. A shower or tub equipped with a showerhead shall have a minimum ceiling height of 6'8' above a minimum area 30" by 30" at the showerhead. See Exception 2, P2708.1. Show plumbing fixtures and clearances around each Show insulation values & Ream VMS: In areas subject to floor heaving, non-bearing walls on basement floor slabs should be built to accommodate not less than 1.111 inches of floor movement. A detail of a typical floated wall is included on Page 3 of this hand-out. 7. FkV61a: Fireblocking must be installed in concealed spaces of wood -furred walls at the ceiling level, at 10 -foot intervals along the length of the wall and at all interconnections of concealed vertical and horizontal spaces such as intersection of stud wails and soffits or dropped ceilings. A detail of typical f+reblocking is included on the following page of this handout. Fireblocks may be constructed of 1-1/2 inch lumber, 3/4 inch plywood, OSB or particle board, 1/2 inch gypsum board or fiberglass insulation 16 inches minimum in height, securely fastened. & Check with your Building Department for insulation requirements. 8. smace Wftr Stalls: If access to the area or space under the basement stairs Is provided for storage or other uses, the walls and ceiling of this enclosed space must be protected an the inside witht/2 inch gypsum board. 10. Toilets must be provided with a minimum of 21 inches in front of the toilet and 15 inches from the center of the toilet and any sidewall or other obstruction. Showers shall have a minimum inside dimension of 900 square inches, capable of encompassing a 30 inch circle and be finished 72 inches above the floor with non-absorbent materials. Shower door minimum clear opening width is 22 inches. See Exception 2, P2708.1. A ventilation fan is required in toilet rooms and bathrooms with unopenable windows. The fan must be vented to the exterior of the building and not to terminate within 3 feet of an opening. 11. LWft & tom: Lighting and ventilation are required for any finished portion of the basement. Contact your Building Department for specific requirements. The Bull 6W cart hell YOU het"" what is 1000S rr to sleet Mi*"= to" iPeQOO MOML 919!13 Floor joist Hint: Install fire stop before installing wall 11 Typical soffif Firebkxk f— Finish here material or here 2x4 or 16°batt insulation secufastened Firehere odc Fireblock concealed aces of turred walls and soffits at 10 -- fastened h$te fart intervals along the length of the wall with 20 lumber, or here plywood or gypsum board nailed to wall stud and held light or here to concrete foundation wall from floor to ceiling. Fill remaining gaps at top and bottom with mineral wool or fiberglass insulation. New 2x4 perimeter wall New 2x4 interior partition Existing concrete foundation wall Wall finish material 40d nails every 24 inches through bottom plate into floor plate. — Pre -drill holes in bottom plate for 40d nails Minimum 1 112 inch void space Pressure treated 20 floor plate anchored to floor slab Spacer -- same thickness as wall finish material — -- — Basement floor slab Emergency Escape And Rescue window wells must provide a minimum area of 9 square feet with a minimum dimension of 36 inches and shall enable the window to open fully. 8 the depth of the window well exceeds 44 inches, a permanently affixed ladder must be provided. The ladder must not interfere with the operation of the window. Window well Net clear dimensions when fully opened to provide 9 square feet of opening. Ladder or stag Emergency 31V or escape or z min' rescue t apenin with gg finished Sii! ".r height below Ladder or stair permitted to the adjacent encroach a maximum of 6 f inches into the required dimensions. This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. Emergency Escape And Rescue Windows must meet the fotkrvring criteria: A minimum total openable area of not less than 53 square feet A minimum dear openable height of not less than 24 inches A minimum dear openable width of not less than 20 inches. A finished sill height of not more than 44 inches above the floor and the window should be openable from the inside with normal operation and without the use of toots, keys or special knowledge. Examples of Complying Height & 20"char Width Combinations —t— 34'!s" clear x`_"-'.'�_'i Openabte area=5.7 24' sq.. clear I Minimum size window 44"max. for 24" clear height clear OpenalMe area -5.7 sq.ft. Minimum size window for 20" clear width 9/9/13 Colorado Chapter of the International Code Council How to Use IM GIMIN Provide two sets of plans, drawn to scale and complete the following (hint. use graph paper with 114' squares. Example: 114' =1'): Check with your jurisdiction for additional requirements. 1. RBVIBW tads BOB" GUMO 2. PPOMG 2 FIM Puns S. HA out a Bdft Permit App on The majority of permit applications are processed with little delay. The submitted documents will help determine if the project is in compliance with building safety codes, zoning ordinances and other applicable laws. Smoke alarms and carbon monoxide alarms are required. The Colorado Chapter of the International Code Council is a professional organization seeking to promote the public health, safety and welfare to building construction. We appreciate your feedback and suggestions. To obtain a master copy of this building guide, please write to the Colorado Chapter of the International Code Council, P.O. Box 961, Arvada, CO 80001. http:/Avww.coloradochapterioc.org Z'x3= 1W 2!.- 2,L ® o J GFcT ' jy -� '�' r' — _ — � --�-- — ....► ... -� � x'-10 Co p�TG ToK U Gto'�t UNFIN t5 H ED ' '" SuwYct ALARM 19 �� ti GFS i $ea ROOM F.' This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. Asl��l's C,",S ► N e.R� s R,e I ekS4e S-+ps -C Wl tvflCL,� City of r OMMUNITY DEVELOPMENT `GEIS T--p-W FCT 'SOALL Co✓u9 U-( 1J I *) � 07v--- City p City of Wbeat Ridge Municipal Building 7500 W. 29' Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 All work is subject to Field Inspection and must comply with the 2012 IRC,2012 IPC, 2012 IMC and the 2014 NEC 3 Burial depth requirements: Electrical - direct burial conductors shall be a minimum of 24 -inches deep, non-metallic conduit 18 -inches deep or 24 -inches under driveways. (IRC Table E3803.1) Water Dines - shall be a minimum of 36 -inches deep. (IRC P2603.6) Gas Service Piping - installed a minimum of 12 -inches below grade or 8 -inches below grade where serving individual outside appliances. An 18 AWG yellow insulated tracer wire must be installed adjacent to underground nonmetallic gas piping and terminate above grade at each end. (IRC G2415.1.2 and G2415.17.3) 4t Underground plumbing pipe shall have a solid and continuous load-bearing support. Piping cannot bear on rocks. Pipes passing under a footing or through foundation wall shall be provided with a relieving arch or a sleeve. Trenches parallel to footing shall not extend below the 45° plane of the edge of the footing. Water piping must be buried a minimum 36 -inches deep. Water service pipe may be installed in the same trench as the building sewer provided the sewer pipe material is listed for underground use within the building or the water service pipe is separated from the sewer by a minimum distance of 5 -feet horizontally or elevated at least 12 - inches above and to one side of the sewer line. S Frost depth to the bottom of the foundation footings must be as noted on the engineered plans. If not noted, the frost depth to the bottom of the footings must be a minimum of 36 -inches below finished grade. (IRC TableR301.2.1) 6 Caisson and helical pier foundations will not be inspected by the city of Wheatridge. A qualified, Colorado - licensed engineer must perform the placement, drilling, and reinforcement of drilled piers. A signed, sealed and dated inspection report must be provided to Building Inspection Services prior to the rough inspections. (8110.5.2.3) 7 A perimeter drain system that discharges to an approved drainage system is required around all foundations that enclose usable spaces below grade. Foundations that retain earth and enclose interior spaces below grade must be damp proofed. (IRC R405. 1,R401.2.14) 8 Slabs below grade must maintain a minimum of 6 -inches above the design water table. The interior finished crawl space grade must be a minimum of 36 -inches above the design water table. (R401.2.1.3and R401.2.1.5) q Garage floor surfaces must be approved noncombustible materials. Floors must be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway. (IRC 8309.1) ) 0 Foundation plates and sills must be bolted to the foundation wall as prescribed on the engineered plans. If not noted, bolts shall have a minimum diameter of %2 -inch, embedded at least 7 -inches and spaced not more than 6 -feet apart. A minimum of 2 bolts are required per plate section, with one bolt located within 12 -inches of each end of each plate. (IRC R403.1.6) "w.cl.wheatridge.ce.us Rough Framing and Wood Requirements i The complete rough inspection is to be made after the rough framing, rough electric, rough plumbing, and rough heat and ventilation are complete. The building should be fully enclosed with the roof covering and siding in place. o Protection from decay shall be provided in the following locations by the use of naturally durable wood or wood that is preservative treated in accordance with AWPA U1: (IRC 8317) A. Wood joists closer than 18 -inches and wood girders closer than 12 -inches to grade located within foundation periphery. or masonry foundation walls and are less than 8 -inches from the B. Wood framing members that rest on concrete exposed ground. C. Sills and sleepers on a concrete or masonry slab that is in direct contact with the ground. D. Wood girders entering concrete or masonry walls with a clearance less than 1/z -inch. E. Wood siding, sheathing, and wall framing less than 6 -inches above the ground. F. Wood members supporting moisture -permeable floors or roofs that are exposed to the weather. G. Wood furring strips or wood members attached directly to the interior of below grade exterior masonry or concrete walls. H. Wood in contact with the ground, embedded in concrete in direct contact with the ground or embedded in concrete exposed to the weather that supports permanent structures intended for human occupancy shall be approved pressure -preservative -treated wood. r :`~Accessible under -floor areas shall be provided with a minimum 18 -inches x 24 -inches opening through the floor or 16 -inches x 24 -inches opening through the perimeter wall. When the access is through a below -grade wall an areaway of not less than 16 -inches x 24 -inches must be provided. Where equipment is located beneath the floor, the access opening must be within 20 -feet of the equipment and allow the removal of the largest piece of equipment. (IRC R408.4 and M1305.1.4) Basements greater than 200 square feet and every sleeping room shall have at least one operable emergency and rescue opening or a door to the exterior. Emergency escape and rescue openings shall meet the following requirements: A minimum clear width of 20 -inches, a minimum clear height of 24 -inches, with a total net clear opening of 5 square feet for grade level windows and 5.7 square feet for all others. A sill height of not more than 44 inches measured from the finished floor to the bottom of the clear opening. Window wells for emergency escape and rescue shall provide a minimum net area of 9 square feet with minimum horizontal projection and width of 36 -inches. The area of the widow well shall allow the emergency escape and rescue opening to fully open. (IRC R310) Columns must be restrained to prevent lateral displacement at the bottom end to insure against uplift. (IRC R301.2.1, R407.3) i 7 Fire blocking shall be installed to cut off all concealed draft openings in the following locations: (IRC 302.11) A. In concealed spaces of stud walls and partitions, including furred spaces, vertically at the ceiling and floor levels, and at 10 -feet horizontal intervals. 11 i. At interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings, and cove ceilings. C - In openings around vents, pipes, ducts, cable, wires, chimneys, fireplaces, and similar openings that afford a passage for fire at ceiling and floor levels. 0. In concealed spaces between stair stringers at the top and bottom of the run, and between studs in line with the run of the stairs at unfinished walls. i a At least one egress door shall be provided for each dwelling unit. The egress door shall be side -hinged, and shall provide a minimum clear width of 32 -inches. Egress doors shall be readily openable from inside the dwelling without the use of a key or special knowledge or effort. (IRC 8311, R311.2) - i 9 'There shall be a floor or landing on each side of each exterior door, The landing must be no lower than 73/ - inches below the top of the threshold of the door provided the door does not swing over the landing. (IRC R311.3) xO Handrails shall be provided on at least one side of stairways with 4 or more risers and ramps with a slope exceeding 1:12. Handrails shall be mounted 34 -inches to 38 -inches above the nosing of the treads. Handrails must be continuous for the entire length of the stairs and provided with a minimum space of 1!/, -inch between the wall and the handrail. Ends shall be returned or terminate in newel posts or safety terminals. See the requirements and more information. (IRC 8311.7.8) � iHandrail Grip Size Shall Be: A. Circular Handrails: 1'/ -inch to 2 -inches perimeter. B. Non -Circular: 4 -inches to 6'/ -inches perimeter with a maximum cross section of 2'/ -inches. *' Perimeter Dimension Greater than 6'/ -inches: shall have a finger recess on both sides. 2� Guards must be provided for porches, screened porches, balconies, fixed seating and raised floor surfaces more than 30 -inches above the floor or grade below. Guards must have a minimum height of 36 -inches. Open sides of stairs with a total rise of more than 30 -inches above the floor or grade below shall have guards not less than 34 -inches high. Intermediate rails shall not allow the passage of a 4 -inch sphere. (R312)Window fall protection must be provided for window openings less than 24 inches above the finished floor and more than 72 inches above grade or surface below. (8312.2) �,3 Ceiling heights for habitable rooms, hallways, bathrooms, toilet rooms, laundry rooms, and basements shall be a minimum of 7 -feet measured from the finished floor to the lowest ojection of the ceiling. Non -habitable basements may have a ceiling height of 6 -feet, 8 -inches with clearance below beams and ducts of 6 -feet, fl- inches. Bathroom may have a ceiling height of 6 -feet, 8 -inches at the fixture front clearance area and over the fixture. (IRC 8305.1) 7A Attic access must be provided for attics that exceed 30 square feet and that have a vertical height of 30 -inches or greater. The access must be located in a hall or readily accessible location with a minimum 22 -inches x 30 - inches access opening. The access must provide a minimum of 30 -inches headroom. (IRC 8807) � Enclosed attic and rafter spaces must have cross ventilation for each space through screened openings. The total net free ventilating area shall not be less than 1 to 150 of the area of the space ventilated. The area may be reduced to 1 to 300 if 50-80% is provided by ventilators located in the upper portion of the space or if a vapor barrier not exceeding 1 perm is installed on the warm side of the ceiling. At least a I -inch space is required between the roof sheathing and the insulation at the location of the vent. (IRC 8806) �6 Rafters must be framed to a minimum 1 -inch nominal ridge board that is not less than the depth of the cut end of the rafter or to each other using a gusset plate. Hip, and valley rafters shall be a minimum of 2 -inches and not less in depth than the cut end of the rafter. Hip and valley rafter shall be supported at the ridge by a brace to a bearing partition or be designed. (IRC R802.3) >7 Rafters and ceiling joists having a depth -to -thickness ratio exceeding 5:1 shall be provided with lateral support at points of bearing to prevent rotation. Rafters and ceiling joists having a depth -to -thickness ration exceeding 6:1 shall be supported laterally by solid blocking, diagonal bridging or a continuous 1 -inch by 3 -inch wood strip nailed across the rafters. (IRC 8802.8) Roof trusses or rafters must be attached to supporting walls with approved hurricane clips. Trusses must be braced to prevent rotation and to provide lateral stability in accordance with the construction documents and the individual truss design drawings. (IRC R502.11.2, R802.11) > Trusses must be designed and fabricated in accordance with ANSI/TPI 1. A licensed professional shall prepare the truss design. Trusses must be legibly marked within 2 -feet of the center to identify the manufacturer, the design load, and the spacing. Truss engineering and layout must be provided at the site at the rough framing inspection. (IRC 8502.11 and R802.10) ) i hoofing material Wood roofs in the plain areas are limited to minimum Class "B" roof coverings. Shingle installation shall meet the manufacturer's high -wind installation procedures in areas where wind load is greater than 105 mph (V3S). Chapter 9, R301.2.1, 8325, and manufacturer's listing All habitable rooms shall be provided with aggregate glazing area for natural light of not less than 8% of the floor area of such rooms. The glazed areas need not be installed in rooms where section M1507 is satisfied and artificial light is provided at an average of 6 foot candles at a height of 30 inches. Safety glazing shall be installed in the following hazardous locations and be permanently labeled as safety or tempered glazing: glazing panels in doors; glazing enclosing spas, bathtubs or showers; glazing panels adjacent and within 24 -inches of the edge of a door; glazing panels greater than 9 square feet within 18 -inches of the floor; glazing used for railings; glazing used for barriers for swimming pools and spas; and glazing enclosing stairways, landings, and ramps within 36 -inches horizontally of a walking surface. (R308.4 through 308.4.7). Skylights must be: (IRC R308.6) = A. laminated glass (with restrictions). B. fully tempered glass (with retaining screen). C. heat -strengthened glass (with retaining screen). D. wired glass (with retaining screen in multiple glazing condition only). E. approved rigid plastic. F. Skylight U -factor required U-0.45. Skylights installed on roofs flatter than 3 units vertical to 12 units horizontal must be mounted on a curb4-inches above the roof. Heating and Ventilation Requirements , I Crawl spaces shall be provided with conditioned air in compliance with Section N 1102.2.10. Crawl space walls shall be insulated. Crawl space wall insulation shall be permanently fastened to the wall and extend downward from the floor to the finish grade level and then vertically and/or horizontally for a least an additional 24 -inches. Exposed earth in unvented crawl space foundations shall be covered with a continuous Class I vapor retarder with a minimum thickness of 10 -mil. All joints of the vapor retarder shall overlap by 6 -inches and be sealed and taped. The edges of the vapor retarder shall extend at least 6 -inches up the stem wall and shall be attached to the stem wall. N1102.2.9.2.2 Ventilated crawlspaces. Ventilated crawlspaces shall be provided with insulation. (IRC 8303.1,) Habitable rooms must be provided with outdoor openings for ventilation equal to at least 4% of the floor area and shall have heating facilities capable of maintaining 68° at 3 -feet above the floor and 2 -feet from exterior walls. P. The windows need not be openable in a room where an opening is not required to be an egress window and a mechanical ventilation system is capable of producing 0.35 air change per hour in that room, or a whole house mechanical ventilation system provides 15 cubic feet of outdoor air per minute. { ty Bathroom exhaust fans shall exhaust directly to the exterior and must be provided in bathrooms where windows of at least 3 square feet are not provided. The mechanical ventilation must be capable of providing an exhaust capacity of 50 cfin intermittent or 20 cfin continuous exhaust. (IRC 8303.3, MI 507.4) 36 Dryer vents must be rigid metallic, independent of all other systems, shall terminate outside the building, be equipped with a back draft damper, and sized and terminated per the manufacturer. The maximum length of the exhaust duct shall be 25 -feet (Unless approved under the manufacturer's listing) from the connection to the transition duct from the dryer to the outlet terminal. Where fittings are used, the maximum length of the exhaust duct shall be reduced in accordance with (IRC Table M1502.4.4.1) Flexible transition ducts are limited to 8 -feet, shall not be concealed within construction, and shall be listed and listed per UL 2158A. (IRC M1502) 37 Appliances and equipment shall be installed in accordance with the conditions of their listing. Manufacturer's installation instructions must be available at the time of the inspection. (IRC G2408.1, M1307.1, M1401.1,M1902.2) 38 Appliances shall be accessible for inspection, service, repair and replacement without removing permanent construction. 30 -inches of working depth and width shall be provided in front of the control side of an appliance. (IRC M 1305.1) 39 Gas and solid fuel appliances located in a garage and hazardous locations shall be elevated so the source of ignition is at least 18 -inches above the floor. Rooms and spaces that are communicate directly with the garage and are not part of the living space shall be considered as part of the garage. Appliances located in garages must be installed at least 6 -feet above the floor or protected from motor vehicle impact. (IRC G2408.2, G2408.3) 40 Combustion air is required for all liquid fuel, solid fuel and gas appliances. (IRC M1701.1, G2407.1) Air for combustion, .ventilation and dilution of flue gases for appliances installed in buildings shall be provided with the requirement of (G2407.6 through G2407.9).One opening shall be 12" below the ceiling and one opening shall be 12 " above the floor. 41 Gas burning appliances may not be located in or obtain combustion air from: a sleeping room, bathroom, toilet room, or storage closet unless it is a direct vent appliance or installed in an enclosure that opens only into a bedroom or bathroom in and such enclosure is provided with a solid weather-stripped door, a self-closing device and all combustion air is taken from the outdoors. (IRC G2406.2) 42 Gas logs installed in solid fuel burning fireplaces shall be tested in accordance with ANSI Z21.60 and installed per the manufacturers installation instructions. Gas logs installed in bedrooms must be direct vent or provided with an approved source of outside combustion air. The approved gas log set must be installed in the Solid -fuel burning appliances at the final inspection. (IRC G2406, G2432, and G243 43 B, BW, and L vents and factory -built chimneys must be provided with a clearance to combustibles per them a manufacturer's listing. Where vents pass through insulated assemblies, they must be provided with an insulation shield. A clearance of 9 -inches is required between single wall vent connectors and combustibles. Gas vents must penetrate through the roof flashing, jack or thimble and terminate in a Chimneys listed cap or per the manufacturers listing. Decorative shrouds installed at terminations shall be listed and installed per the manufacturer. (IRC G2425, G2426, G2427) Electrical Requirements 44 All electrodes present at each structure shall be bonded together to form one grounding electrode system to include: Concrete Encased Electrodes (LIFER), water piping, ground rings, grounding rods, and plate electrodes. Bonding shall ensure electrical continuity. The electrode conductor must be connected in an approved manner and inspected prior to concealing. (IRC E3607, E3608, E3609, E3610, E3611) 45 All hot, neutral, and grounding conductors in electrical boxes shall be tied together with a mechanical connection at the time of rough inspection. Recessed lighting fixtures must either be IC -rated or installed in a sealed box in which the insulation is at least 3 -inches from the light fixture. All recessed lights must be tightly sealed or gasketed to prevent air leakage through the fixture into the ceiling cavity. (IRC N1102.4.5) i Tamper -Resistant receptacle outlets are required in every kitchen, family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room or similar dwelling areas spaced so that no point along the wall line exceeds 6 -feet from an outlet. (IRC E3901, E3902, and 4002.1-4002.14) Counters 12 -inches in width or wider shall have receptacles placed no more than 20 -inches above the counter top and spaced so no point exceeds 24 -inches from an outlet. til, Island and peninsula counters with a length at least 24 -inches and a width of 12 -inches or greater must be equipped with at least one outlet.: '. At least one receptacle shall be installed in a bathroom within 36 -inches of each basin. A least one receptacle outlet must be installed in each laundry, basement, attached garage and detached garage with power. (.'. Attics or crawlspaces containing equipment must be provided with at least one receptacle outlet within 25 -feet of the equipment. 1), Hallways 10 -feet or more in length.(E3901.1) Two 20 -amp rated branch circuits shall serve receptacles in the kitchen, pantry, breakfast area, and dining area. "At least one 20 -amp branch circuit shall supply bathroom receptacles and at least one 20 -amp branch circuit shall supply laundry. (IRC E3703.2, E3703.3, E3901) �.) Qround fault protection shall be provided on all 125 -volt, single phase, 15 and 20 -amp receptacles in the following locations: bathrooms, garages, unfinished grade level accessory buildings, at exterior locations, crawlspaces, unfinished basements, kitchen counters, within 6ft. of laundry, utility and wet bar sinks, boathouses, hydro massage, spa and hot tub locations. Receptacles must be in a readily accessible location. (IRCE3902, E3902.11) k Combination type arc -fault circuit interrupters must be installed on all 120 -volt 15 and 20 -amp branch circuit outlets in receptacle outlets are required in every family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room, hallway, closets, and similar dwelling areas. (IRC 3902.12) At least one wall switch -controlled lighting outlet shall be installed in every habitable room, bathroom, hallway, (1 Oft) stairway, attached garage, detached garage with electric power, and at the exterior side of each outdoor egress door having grade level access. Attics, under floor spaces, utility rooms and basements containing equipment or used for storage must be provided with a switch operated light. (IRC E3903) Smoke alarms shall comply with UL 217. Smoke alarms are to be powered by the building's wiring with battery backup and shall be interconnected so the actuation of one alarm will activate all alarms in the dwelling unit.(R314.5) Smoke alarms shall be installed in the following locations: (IRC R314) A. In each sleeping room; Outside each sleeping area in the immediate vicinity of the bedrooms; and " One on each additional story including basements. .h Carbon Monoxide alarms are required in asingle-family dwelling that has fuel -fired appliance(s), or a fireplace, or an attached garage. The alarm must be installed within 15 -feet of the entrance to each sleeping room. Must be listed by a nationally recognized, independent lab. Plugs into a dwelling's electrical outlet and has a battery backup. They may be combined with a smoke -detecting device if the combined device complies with applicable law. (IRC 8315) Clothes closet lighting shall be limited to surface -mounted or recessed incandescent fixtures with completely enclosed lamps, and surface -mounted or recessed fluorescent fixtures. Recessed fluorescent fixtures shall have a minimum 6 -inch clearance to the nearest point of storage. G r 10 Working space must be provided around energized equipment for servicing and maintenance. The minimum dimensions shall not be less than 36 -inches in depth and 30 -inches in width in front of the equipment. Working space shall extend to at least 6 -feet, 6 -inches above the floor. (IRC E3405.2) 1�7 Electrical fixtures installed in wet or damp locations shall be installed so that water cannot enter or accumulate n wiring compartments or other electrical parts. Fixtures installed in suet locations must be labeled "suitable for wet locations". Fixtures installed in damp locations must be labeled "suitable for damp locations" or "suitable for wet locations". Switches or circuit breakers located in wet locations or outdoors must be enclosed in a weatherproof enclosure. Outdoor receptacles must have a weatherproof enclosure and an in -use cover. Cord -connected fixtures, hanging fixtures, track lighting, pendants, and ceiling fans shall not be located within3-feet horizontally and 8 -feet vertically from the top of a tub or shower rim. (IRC E4003.9, E4002.8, E4002.9,E4002.10, E4003.9, E4003. l 0,E4003.11) S9 DWV systems shall be tested on compellation of the rough piping installation by water or for piping system other than plastic by air with no evidence of leakage. Either test shall be applied to the drainage system in its entirety or in sections after rough piping has been installed . i 1, Water test 10 feet above the highest fitting connection or to the highest point of the completed system. The system shall prove leak free for 15 minutes. �l Air test shall maintain 511s of pressure for 15 minutes. S9 Piping must be inspected and tested prior to concealing. It shall be protected against physical damage and it must be approved for use and bear the identification of the manufacturer. (IRC P2503, P2603, P2608.1) 60 Bathtubs, walls above bathtubs with shower heads, shower floors, and shower compartments shall be finished with a non-absorbent surface which extends to a height not less than 6' above the floor. Showers must have a minimum 900 square inches of interior area and a minimum dimension in each direction of 30 -inches. Shower valves must be pressure balance/thermostatic mixing valves. Shower receptors shall have a curb threshold not less than 1 -inch below the sides and back of the receptor. The curb shall measure a minimum of 2 - inches to a maximum of 9 -inches above the top of the drain. (IRC 8307, P2708, P2709) 6 1 The centerline of toilets or bidets shall not be less than 15 -inches from adjacent walls or tub. Toilets, bidets, and lavatories must have a minimum clear space of 21 -inches in front of the fixture. Lavatories require a 4 -inch clearance to wall or to a toilet. (IRC P2705) 6� Showers and tub/shower combinations shall have control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with high limit stop per ASSE 1016 or CSAR 125.1. Tubs shall also have a control valve as listed for a shower or a water -temperature -limiting device that conforms to ASSE 1070. The high limit stop for a device shall be set to a maximum of 1200. (IRC P2708.3,P2713.3) 6-1 Shower doors shall have safety glazing, hinged shower door shall open outward (R308.4.5, P2708.1) 64 Backflow prevention must be provided to prevent contamination of potable water. This includes but is not limited to: hose connections, irrigation systems, boilers, solar systems, fire sprinklers, and dishwashers. (IRCP2902.2, Table P2902.3, P2717) Insulation R-20 Walls (new construction) R-49 Ceiling R-19 Crawlspace Windows .32 Floor R-30 6, Supply Ducts in attics shall be insulated to a minimum of R-8. All other ducts shall be insulated to minimum R-6. ( N 1103.2. 1) 6'/ Combustible insulation shall be separated a minimum of 3 -inches from fan motors and heat -producing devices. Insulation shields must be provided where vents pass thorough insulated assemblies and must terminate at least 2 -inches above attic insulation materials. Can lights must be airtight if located in the building envelope. Wallboard Requirements Wallboard Requirements The garage shall be separated from the residence and its attic by materials of not less than '/2 -inch gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5/8 -inch Type X gypsum board. Openings between the garage and residence shall be equipped with solid wood doors not less than 1 -inch in thickness, solid or honeycomb core steel doors not less than 1 -inch thick, or 20 -minute fire -rated doors. Openings are prohibited between garages and rooms used for sleeping. Doors between attached garages and living space shall be weather stripped to the degree necessary to make them airtight and shall be self-closing and self -latching. (R302.5.1) ,6q Enclosed accessible space under stairs shall have walls, under stair surface and any soffits protected on the enclosed side with'/2-inch gypsum board (IRC R302.7). i(I Cement, fiber -cement, glass mat gypsum backer and fiber reinforced gypsum in compliance with ASTM C 1288, C 1325, C1178, or C1178 and installed in accordance with manufacturer recommendations shall be used as backers for wall tile in tub and shower areas and wall panels in shower areas. (IRC R702.4.2) Nail spacing for gypsum board , /2 "e0ir g 16oc 7" nails 12" Type S screws, 1/2watt spacing 24"oc 8"nails, 12 "screws. 5/8 ceiling 16oc 7" nails 12"type S screws 5/8 wp_'N 24oc 8"nails 12" type S screws. I t Water-resistant gypsum backing board used as the base or backer for adhesive application of ceramic tile or other required nonabsorbent finish material shall conform to ASTM C1396 , C1178 or C1278. All cuts and exposed edges shall be sealed. (IRC R702.3.8) Final Inspection Requirements 10 Buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. 4" high, with a minimum stroke of 1/2" (IRC 319) 10 All dwellings shall have a controlled method of water dispersal from roofs that will collect and discharge all roof drainage at least 5 -feet from the foundation. Gutters, downspouts, downspout extensions shall be deemed adequate to meet these requirements. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6 -inches within the first 10 -feet. (IRC 8401.3 and 801.3) Bill Myers pl ner/ Combination Inspector 7500 W. 29n' Ave Wheat Ridge, Co 80033-8001 303-235-2878 Cr,T /// 2490 llj�lplqllll� �plll pjj11111plllllqpl� I ulitimOR!e�� fjjsr4e-/-4-r/o/J-5 A42,6- TU5 losmavoov; R�C(j my I>RfwIA14 ', 0160- &W-,) I M7(2�6� oc e za. 4�^ R A io,—NOO Ll tA c3l; cj 7 0. 8/0 toaj,e rza L S e&MteXJ -6 F ro,(C Tlik--) P.A St,'Ml Tt1 'I's D4Y lo -o-07" fjjsr4e-/-4-r/o/J-5 A42,6- TU5 losmavoov; R�C(j my I>RfwIA14 ', 0160- &W-,) I M7(2�6� oc e za. 4�^ R A io,—NOO Ll tA c3l; cj 7 0. 8/0 toaj,e • ?� s.Art, 7't.. '.t'1zz'•".:.:,%':6f,4�'.Y4':�C•,7.7k�#'.+c+"'.�Ts�." 9,': ".ISP'.+*dw'.ns',' ,'i."�C':C '.! 'f" .-: f. ,i"� �e"'. k"-'�'.' ,','_ 0"d a'�"g"f 3:;. .. r F% t of t NMAJ ekwir.X30 Stu Our wto, M104 aft wti>TN CUT 'dt". A t-, 0k Nj VU.t� . W ww"> WUL's ". tri( STK � CZ, - IL v6-S- Cecil Rickstrew, P.E. 1627 Glen Moor Dr. Lakewood, CO 80215 July 16, 2017 Jeff Wood Jeffwoodwoodwork@gmail.com '?E: 3090 Reed St., Wheat Ridge, CO Jeff Pig #: 303-668-2382 E-mail: Cecil @ecsidenver,com This letter shall serve as this engineer's field inspection report of 7-14-17 with respect to he above referenced 10 1960 +/- constructed home. The inspection revealed the developer wanted to remove main floor bearing walls supporting ceiling joist and roof joist supports. 1. The developer wanted to remove the bearing wall between the east kitchen and the west living room area which will require a 24' span drop beam of (3) 1 1/" x 14" LVLs supported on (2) 2x6 columns as shown in elevation 1 looking west on the at.ached page. 2. The developer wants to remove two hall way 12' bearing walls at the south end of the home to make a large master bedroom. Such will require a drop beam of (2) 1. 2/4" s 1 � 9 ;%" LVL to support the ceiling joist and roof joist supports. a. The west hall way bearing wall aligns directly over a basement bearing wall below --no new drop beam and columns is shown on the attached page of elevation 2 looking west. The east hall way bearing wall bears on the floor joist, thus the new north columr. must be supported by two additional 2 x10 floor joist installed in the main floor directly under the north column as shown in elevation 3 looking west as found or, the attached page 3. The existing double 2x10 header at the stair to the basement doesn't allow Tor tnv' required 6'8" clear headroom from the toe of the stair tread to the header above. The solution is to remove the double 2x10 header which project below the 3' hallway into Lbe stairs and install a 1 %" x 5 %" LVL header directly above the ends of the joist as snown in Section 4 on the attached page. Undertaking the remediation as referenced above will leave the home structurally sound in the area of remediation. �_ecil Rickstrew, P.E. u d used in bullding,design - ----- --------- ----------------------------3 v`.:.. Load i inu Load------------------------------------------ 't4i� m.p.h. t� >> Uj 'eismic Loads --------------------Seismic eld�s L) Seismic dc5: n Cain! Ott L) 53�N O -o, � D. :an Code is TRC 201 l.,V LA,Yt - Wood: All Fraznins_% lumber shall be Doug Fir '"' or better or egtia, dew, j .OM7�'1vewty�,rr resistant f're-en,,meered lumber shall be by truss .lois, for I jo;st n ; ?a�tirclan�s iur e'Ls if b==800 p.s.i.). LVL beams shall be securer to eth r �,it'r: ilia p , s ai i'-- o.c. each top and hotiom unless otheniise noted. 1ra,.iu.iL, connectors shall be b Simpsi311 titronl,: 9 ie. Antoinette Kulick From: Antoinette Kulick Sent: Monday, November 6, 2017 9:54 AM To- 'Jeffwoodwoodwork@gmail.com' Cc: Brian Tardif; Kimberly Cook Subject: 3090 Reed St Hi Jeff, Your plans for the remodel at the above stated address have been approved, however in the review we noticed you have asbestos as called out in the report submitted. If you are abating the asbestos we need the abatement report as well as the permit from the state of Colorado. Once this has been received, the total balance due is $2069.10. Prior to permit issuance we need a General Contractor on record as well as any and all subs ie, Electrician, Plumber, Mechanical contractor etc. Our counter hours for this type of permit are 7:30am-10:30am. Please let me know if I can be of further assistance. Sincerely, Antoinette Kulick Permit Technician 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2873 Fax: 303-237-8929 www.ci.wheatridge.co.us 4 ili° cA W �1�'-c`3.t CONFIDENTIALITY NOTICE: This e-mail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you. City Of W heat lki jgc COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a-)-ci.wheatridge.co.us FOR OFFICE USE ONLY Date: j)//„ 17 Plan/Permit # A/z 4 Plan Review Fee: f % Building Permit Application Please complete all highlighted areas on both sides of this form. Incomplete applications Property Address: 3 o / o1\ ke- e D ,/`ter be processed.'”" Property Owner (please print): %ti c �,�, > r/L �p ( �� ?c_ Phone: 50:5'. Property Owner Email rlc 4,420011.0 Mailing Address: (if different than property address) Address: I 9- E /= Ts C.t ,✓ City, State, Zip: Ce^j re1,v t.ra 1 ('e Z Q 1�5\_ \\NAn n CC. Architect/Engineer E-mail: 1 0 X 5 10e'V")'!'- Phone: 3o� G G A-.2 Contractor: ,q9ji Contractors City License #: Z(] Phone: ( l Coia*ractor E-mail Addres Sub Contractors: Electrical: VV I PV y :� (e W.R. City License # �i Z Other City Licensed Sub: City License # Plumbing: Mechanical: W.R. City License # W.R. City License # Other City Licensed Sub: City License # Complete all information on BOTH sides of this form 35 o- 5366 Godding Hollow Parkway Longont, CO 80504 EARTH ENERGY ENVIRONMENT (E3) Locam3034778-0922 Industrial Hygiene and Environmental Engineering August 11, 2017 Mr. Jeff Wood Property Representative 3090 Reed Street, Wheat Ridge, CO Subject: Asbestos Sampling Results — 3090 Reed Street, Wheat Ridge, CO Dear Jeff. On August 9 2017, an Industrial Hygienist with Earth Energy Environment (E3) performed an inspection and asbestos sampling on a residential property located at 3090 Reed Street, Wheat Ridge, CO. E3 was retained by a property representative to determine if the accessible building materials within the property contain asbestos. SURVEY METHODOLOGY An industrial hygienist from E3 conducted the sampling. Materials were grouped into homogeneous sampling areas based on the material type. Among the interior building materials, fourteen (14) distinct homogeneous areas throughout the property were identified and sampled. Homogeneous Material Classifications A preliminary walk through of the buildings was conducted to determine areas of materials which were visually similar in color, texture, general appearance, and which appeared to have been installed at the same time. Such materials have been termed "homogeneous materials" by the EPA. During this walk through, the approximate locations of these homogeneous materials were noted. Following the EPA inspection protocol, each identified suspect homogeneous material was placed in one of the following EPA classifications: o Surfacing Materials - Sprayed or troweled on surfaces (walls, ceilings, structural members) for acoustical, decorative, or fireproofing purposes. This includes plaster and fireproofing insulation. o Miscellaneous Materials - Other non -friable products and materials such as floor tile and ceiling tile. o Thermal System Insulation - Insulation used to inhibit heat transfer or prevent condensation on pipes, boilers, tanks, ducts, and various other components of hot and cold water systems and heating, ventilation, and air conditioning (VAC.) systems. This includes pipe lagging, pipe wrap, block, batt, blanket insulation, cements, muds, gaskets and ropes. (These materials were not sampled as part of the survey.) 21P age Friability Classifications Friable and non -friable ACM's are defined as follows: Friable asbestos -containing material: any material containing more than 1% asbestos, determined using PLM analysis, that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Category I nonfriable asbestos -containing material: asbestos -containing resilient floor covering, mastic or asphalt roofing product containing more than 1% asbestos as determined using PLM. Category II nonfriable asbestos -containing material: any material, excluding Category I non -friable ACM, containing more than 1% asbestos as determined using PLM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. Regulated asbestos -containing material (RACM): (1) friable ACM, (2) Category I nonfriable ACM That has become friable, (3) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (4) Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the materials in the course of demolition or renovation operations. Sampling and Laboratory Analysis Bulk samples were collected by using various sampling tools (cutting tools, knives and chisels) to cut away or scrape portions of suspect building materials into zip -sealed plastic bags or sampling tubes. The individual samples were labeled by material type and location. Samples were analyzed by Reservoirs Environmental Laboratory located in Denver, CO. The laboratory maintains accreditations through the American Industrial Hygiene Association (AIHA), and National Voluntary Laboratory Accreditation Program (NVLAP). The analysis performed was EPA Method 600/R-93/116. INSPECTION RESULTS E3 collected at least the minimum number of samples from each homogeneous area necessary to meet all regulatory requirements for the quantity of material to be observed. Table 1 provides a summary of the homogenous areas. 3 1 P a g e Table 1. Homogeneous and Functional Sampling Areas. Material Material Physical Classification Samples HA Type Description Description Collected I Attic Debris Insulation A Black debris Thermal System 3 Insulation Insulation 2 Floor Debris Demolition A Off white/multi-colored debris Surfacing 3 Debris on Floors Materials A Brown gold/black resinous 3 Bathroom Walls material Surfacing 3 Walls B Off white granular plaster Materials C White plaster A Tan resinous material 4 Kitchen Walls B White plaster w/ beige/multi- Thermal System 3 Walls colored paint Insulation C Off white granular plaster A White plaster w/ pink paint Surfacing 5 Stair Walls Walls B Light pink granular plaster Materials 3 C White/tan all Light Green A White plaster w/ light green 6 Walls and Walls and paint Surfacing 5 Ceilings Ceilings B White/tan drywall Materials C Light pinkgranular plaster Back A White texture w/ pink paint B Surfacing 7 Bedroom Walls White plaster w/ pink paint Materials 3 Walls C Light pink granular plaster A White/pink flooring w/ white 8 Bathroom Vinyl Floors fibrous backing material Surfacing 3 Floors B pink flooring w/ black felt Materials backing material Kitchen Surfacing 9 Floor Vinyl Floors A Green/multi-colored flooring Materials 3 (Layer 1) 10 Ceiling Tiles 1 foot x I feet A Brown/white ceiling tile Surfacing 3 ceiling tiles Materials A Tan adhesive 11 Basement 9 inch by 9 inch B Gray granular cementitious Surfacing 3 9x9 tiles floor tiles material C Off white/multi- Materials colored sheet vinyl A Black adhesive 12 Kit Floor Vinyl Flooring B Off white/multi-colored sheet Surfacing 3 (Layer 2) vinyl w/ black fibrous backing Materials material A Brown adhesive 13 Kit Floor Vinyl Flooring B Off white sheet vinyl w/ gray Surfacing 3 (Layer 3) fibrous backing material Materials 14 Duct Wrap A Tan fibrous material Miscellaneous 3 Materials 41 Page The laboratory separated and analyzed individual layers within each sample, if present. According to the laboratory analysis of the materials sampled, asbestos was detected in bathroom within the flooring and brown resin on the walls. The duct wrap was not sampled, but is assumed to be asbestos containing. Table 2. Asbestos Containing Materials HA Material Type Material Physical Asbestos Description Description Content Bathroom A Brown goldiblack resinous material o 3 Glue/Resin B Off white granular plaster Zhr sotile C White plaster Bathroom Vinyl A White/pink flooring w/ white fibrous 25% 8 Floors Flooring backing material Chrysotile B Pink flooring w/ black felt backing material 13 Duct Wrap Insulating/ Sealant Wrap Tan fibrous material assumed "hn sotile Bathroom Black/Gold Resin Bathroom Flooring Duct Wrap 51rz,_•_ CONCLUSIONS AND RECOMMENDATIONS According to the laboratory analysis of the interior building samples. asbestos was detected in the bathroom flooring and wall resin. The duct wrap was not sampled, but is assumed to be asbestos containing. A portion of the flooring (12 square feet) and the bathroom wall resin (15 square feet) were disturbed by the remodeling activities. The bathroom is therefore considered a minor spill area. Visual inspect indicates the spill is limited to within the bathroom. A minor spill response followed by remediation/removal of the asbestos containing materials by a Colorado Certified Abatement contractor is recommended. The Colorado Department of Public Health and the Environment requires any asbestos -containing material that is friable or will be made friable during demolition/renovation activities be removed prior to demolition or renovation. Any potential asbestos containing materials identified in the future or during demolition that were not sampled in this, or any other previous survey, should be tested for asbestos content or assumed to contain asbestos before being disturbed. If you have questions or require additional information, please contact me at (303) 478-0922. Sincerely, Art Willden Certified Building Inspector No. 20138 Reaervars Ermronmental, Inc. Effective January 1, 2015 Reservoirs Environmental QA Manual TAQA.QC11ab1Reservoirs Environmental QA Manual doc R E�'Reservoirs Environmental, Inc. T - August 10, 2017 Earth Energy and Environment Corp. 5366 Godding Hollow Pkwy Longmont CO 80504 Dear Customer, Subcontract Number: NA Laboratory Report: RES 386864-2 Project # / P.O. # None Given Project Description: 3090 Reed Street Wheatridge Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 386864-2 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, Jeanne Spencer President R 303-964-1986 5801 Logan Street, Suite 100 Denver, CO 80216 1-866-RESI-ENV F 303-477-4275 vrvw.reilab.corn Page 1 of 1 Reservoirs Environmental, Inc. Reservoirs Environmental OA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effective January 1, 2015 O 10AOCUAMReservous Emnonmental OA Manual doc ND None Detected ITR=Trace, <1 % Visual Estimate ! Trem/Act=Tremolite/Actinolite i Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R (%) Asbestos Content Mineral Visual Estimate Non Asbestos Fibrous Components Non - Fibrous Components Attic Debris -1 EM 1917633 A Black debris 100 ND 5 95 Attic Debris -2 EM 1917634 A Black debris 100 ND 5 95 Attic Debris -3 EM 1917635 A Black debris 100 ND 2 98 Floor Debris -1 EM 1917636 A Off white/multi-colored debris 100 ND 2 98 Floor Debris -2 EM 1917637 A Off white/multicolored debris 100 ND 5 95 Floor Debris -3 EM 1917638 A Off white/multi-colored debris 100 ND 10 90 Bath Walls -1 EM 1917639 A Off white granular material 2 ND 0 100 B White plaster 98 ND 0 100 Bath Walls -2 EM 1917640 A Off white granular plaster 10 ND TR 100 B Off white/tan drywall 90 ND 15 85 Bath Walls -3 EM 1917641 A Brown gold/black resinous material 10 Chrysotile 16 0 85 B Off white granular plaster 15 ND TR 100 C White plaster 75 ND 0 100 TEM Analysis recommended for organically bound material (i.e. floor tile) 'f PLM results are <1%. P: 303-964-1986 5801 Logan Street, Suite 100, Derver, CO 80216 1-8WRESI-ENV F : 303477-0275 wvhv reilab.corn Page 1 of> Reservoirs Ewironmental. Inc. Reservoirs ErrvironmeMal QA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number. RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samoles Received: Auaust 09. 2017 EffecW. January t, 2015 0 \QAQCUABV2esem- Environmental QA Manual.doc Method: EPA 600/R-93/116 - Short Report, Bulk I ND=None Turnaround: 2 Hour TR=Trace, Trem/Act=Tremolite/Actinolite Date Samples Analyzed: August 09, 2017 Detected <1% Visual Estimate f �� Client Lab L Asbestos Content Non Non - Sample ID Number A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components Kit Walls -1 EM 1917642 A Tan resinous material 25 ND 0 100 B White plaster w/ beige/multi-colored paint 25 ND 0 100 C Off white granular plaster 50 ND TR 100 Kit Walls -2 EM 1917643 A White plaster w/ yellow/multi-colored paint 25 ND 0 100 B Off white granular plaster 75 ND TR 100 Kit Walls -3 EM 1917644 A Tan resinous material 10 ND 0 100 B White plaster 10 ND 0 100 C Off white granular plaster 80 ND TR 100 Stair Walls -1 EM 1917645 A White paper w/ pink paint 50 ND 0 100 B Light pink granular plaster 50 ND 0 100 Stair Walls -2 EM 1917646 A White plaster w/ pink paint 25 ND 0 100 B Light pink granular plaster 35 ND TR 100 C White/tan drywall 40 ND 15 85 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO BD216 1-866-RESI-ENV F: 303-0774275 Pace 2 of 7 w+. w.reilab.com Reservoirs Emironmental, Inc. Reservoirs Emironmental OA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/11-93/116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effective January 1, 2015 OtOAOW.ABU2eaery m Environmental OA Manual.doc ND=None Detected —7 ITR=Trace, <1% Visual Estimate ITrem/Act=Tremolite/Actinolite I I i Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R (%) Asbestos Content Mineral Visual ? Estimate (%) Non Asbestos Fibrous Components (%) Non - Fibrous Components (%) Stair Walls -3 EM 1917647 A Light pink granular plaster 45 ND TR 100 B White plaster w/ pink paint 55 ND 0 100 Swirl Ceiling -1 EM 1917648 A White plaster w/ white paint 50 ND 0 100 B Light pink granular plaster 50 ND TR 100 Swirl Ceiling -2 EM 1917649 A Light granular piaster 40 ND 0 100 B White plaster w/ off white paint 60 ND 0 100 Swirl Ceiling -3 EM 1917650 A Light pink plaster 35 ND 0 100 B White plaster w/ white paint 65 ND 0 100 Lt Green W/C-1 EM 1917651 A Light pink granular plaster 15 ND 0 100 B White plaster w/ light green paint 85 ND 0 100 Lt Green W/C-2 EM 1917652 A Light pink granular plaster 20 ND 0 100 B White plaster w/ light green paint 80 ND 0 100 Lt Green W/C-3 EM 1917653 Sample Not Received. TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303964-1986 5801 Logan Street, Suite 100, Demer, CO 80216 1-866-RESI-ENV F: 303A77-0775 wwx.reilab.cam Page 3 0! Sat, Aug 19 04:00 PM - 05:45 PM Colorado Legacy (Dean) vs. RMT (Goodnight) Sat, Aug 19 04:00 PM - 05:45 PM Untouchables (Graves) vs. Wolves (Sprague) Sat, Aug 19 04:00 PM - 05:45 PM 14 Raptors Black (Odonnell) vs. Warriors Cardinal (Page) GAME Englewood, Cornerstone 2 GAME Englewood, Cornerstone 1 GAME Parker, Iron Horse #2 Sat, Aug 19 05:45 PM - 07:30 PM RMT (Goodnight) vs. Untouchables (Graves) GAME Englewood, Cornerstone 1 Reaervolrs Environmental, Inc. Reservoirs Emrimirnental QA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896.0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effective January 1, 2015 0'\QAQCU.AB1Reaen,olrs Environmental QA Manual doc ND=None Detected - TR=Trace, <1% Visual Estimate l Trem/Act=Tremolite/Actino lite ___ Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R Asbestos Content Mineral Visual Estimate Non Asbestos Fibrous Components Non - Fibrous Components Lt Green W/C4 EM 1917654 A White plaster w/ light green paint 10 ND 0 100 B White/tan drywall 40 ND 15 85 C Light pink granular plaster 50 ND TR 100 Lt Green W/C-5 EM 1917655 A White plaster w/ light green paint 10 ND 0 100 B White/tan drywall 35 ND 20 80 C Light pink granular plaster 55 ND TR 100 Lt Green W/C-6 EM 1917656 A White plaster w/ light green paint 10 ND 0 100 B White/tan drywall 40 ND 15 85 C Light pink granular plaster 50 ND TR 100 Back Bid Multi Color Walls -1 EM 1917657 A White texture w/ pink paint 15 ND 0 100 B White plaster w/ pink paint 20 ND 0 100 C Light pink granular plaster 65 ND 0 100 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-86"Eq-FNV F: 303477-4275 —reilab— Page 4 of 7 Sat, Aug 19 12:30 PM - 02:15 PM BC Green (Salgado) vs. Hawks White (Betschart) GAME Englewood, Cornerstone 1 Sat, Aug 19 12:30 PM - 02:15 PM Eagles White (Martinez) vs. Spartans White (Klatt) GAME Parker, Iron Horse #2 Sat, Aug 19 12:30 PM - 02:15 PM Hawks Blue (Wickstrom) vs. Warriors Fire (Burtt) GAME Parker, Iron Horse #1 Sat, Aug 19 12:30 PM - 02:15 PM Warriors Crimson (Gooden) vs. Warrior Red (Lohani) GAME Englewood, Cornerstone 2 Sat, Aug 19 12:30 PM - 02:15 PM Denver War Eagles (Fee) vs. Prodigy (Acree) GAME Aurora, Mission Viejo # 1 Sat, Aug 19 12:30 PM - 02:15 PM RMT (Cameron) vs. Colorado Peak (Maestretti) GAME Aurora, Mission Viejo # 2 Sat, Aug 19 12:30 PM - 02:15 PM Colorado Legacy (Hagardt) vs. RMT (Reimers) GAME Aurora, Mission Viejo # 4 Sat, Aug 19 12:30 PM - 02:15 PM Eagles Riptide (Franco) vs. Eagles Green (Beranek) GAME Aurora, Mission Viejo # 3 Sat, Aug 19 02:15 PM - 04:00 PM Colorado Legacy (Dean) vs. Rado Eagles (Shellhorn) GAME Englewood, Cornerstone 3 Sat, Aug 19 02:15 PM - 04:00 PM Warriors Steel (Mimless) vs. Warriors Crimson Gooden Sat, Aug 19 02:15 PM - 04:00 PM Warriors Iron (Barbre) vs. 14 Raptors Black Odonnell GAME Englewood, Cornerstone 2 GAME Parker, Iron Horse #2 Sat, Aug 19 02:15 PM - 04:00 PM 14 Hawks Orange (Weiman) vs. Hawks Green GAME Parker, Iron Horse #1 (Cunningham) Sat, Aug 19 02:15 PM - 04:00 PM Warriors Cardinal (Page) vs. 14 Hawks Blue (Adams) GAME Parker, Iron Horse #3 Sat, Aug 19 02:15 PM - 04:00 PM Hawks White (Betschart) vs. Hawks Orange (Bachli) GAME Englewood, Cornerstone 1 Sat, Aug 19 02:15 PM - 04:00 PM Crush (Mitchell) vs. RMT (Heathcoat) GAME Castle Rock, DCFG 1 Reservoir: Environmemal, Inc. Reservoirs Errvironmental OA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effective January 1, 2015 tr\OAOCUABV2eservoirs Environmental OA Manual.doc ND=None Detected TR=Trace, 1% Visual Estimate Trem/Act=Tremolite/Actinolite Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R (%) Asbestos Corttent Mineral Visual Estimate (a/o) Non Asbestos Fibrous Components (%) Non - Fibrous Components (%) Back Bird Multi Color Walls -2 EM 1917658 A White plaster w/ pink/multi-layered paint 45 ND 0 100 B Light pink granular plaster 55 ND 0 100 Back Brd Multi Color Walls -3 EM 1917659 A Light pink granular plaster 10 ND 0 100 B White plaster w/ purple paint 90 ND 0 100 Bath Floor -1 EM 1917660 A White/pink flooring w/ white fibrous backing material 48 Chrysotile 25 5 70 B Pink flooring w/ black felt backing material 52 ND 45 55 Bath Floor -2 EM 1917661 Not Analyzed per Client Request. Bath Floor -3 EM 1917662 Not Analyzed per Client Request. Kit Floor -1 EM 1917663 A Green/multi-colored flooring 100 ND 0 100 Kit Floor -2 EM 1917664 A Green/multi-colored flooring 100 ND 0 100 Kit Floor -3 EM 1917665 A Green/multi-colored flooring 100 ND 0 100 Ceiling Tiles -1 EM 1917666 A Brown/white ceiling file 100 ND 85 15 Ceiling Tiles -2 EM 1917667 A Brown/white ceiling file 100 ND 90 10 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-%411986 5801 Logan Street Suite 100, Denier, CO 80216 1-866-RESI-ENV E: 303A7/-4775 vw.w.reilab.00m Page 5 of 7 Sat, Aug 19 10:45 AM - 12:30 PM Raptors Green (Steiner) vs. Eagles White (Varholak) GAME Englewood, Cornerstone 1 Sat, Aug 19 10:45 AM - 12:30 PM RMT (Heathcoat) vs. EC Coyotes (Hayes) GAME Castle Rock, DCFG 3 Sat, Aug 19 10:45 AM - 12:30 PM Eagles Green (Maloney) vs. RMT (Lewis) GAME Castle Rock, DCFG 2 Sat, Aug 19 10:45 AM - 12:30 PM 14 BC Legends (Garcia) vs. Warriors Crimson GAME Parker, Iron Horse #1 (Weiss) * * time change Sat, Aug 19 12:30 PM - 02:15 PM Wolves (Sprague) vs. Rado Eagles (Shellhorn) GAME Englewood, Cornerstone 3 Sat, Aug 19 12:30 PM - 02:15 PM All American (Romero) vs. Untouchables (Martinez) GAME Castle Rock, DCFG 1 Sat, Aug 19 12:30 PM - 02:15 PM RMT (Lewis) vs. Crush (Madison) GAME Castle Rock, DCFG 2 Sat, Aug 19 12:30 PM - 02:15 PM Prodigy (Simco) vs. Psyclones 04 (Kinder) GAME Castle Rock, DCFG 3 Sat, Aug 19 12:30 PM - 02:15 PM Warriors Black (Kunz) vs. Eagles Black (Broadrick) GAME Highlands Ranch, Northridge 3 Sat, Aug 19 12:30 PM - 02:15 PM Hawks Green (Cunningham) vs. Warriors Iron GAME Parker, Iron Horse #3 Barbre * * time change Sat, Aug 19 12:30 PM - 02:15 PM Hawks White (Reed) vs. Warriors Scarlet (Farley) GAME Highlands Ranch, Northridge 2 Sat, Aug 19 12:30 PM - 02:15 PM Spartans Gold (Stevens) vs. Hawks Blue (Carpenter) GAME Highlands Ranch, Northridge 1 Reservoirs Environmental, Inc. Reservoirs Emimninental QA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client: Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: August 09, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 2 Hour Date Samples Analyzed: August 09, 2017 Effective January 1, 2015 QAQAQCLLA8XReservoirs Environmental QA Manual.°oc ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite j Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R Asbestos Content Mineral Visual Estimate Non Asbestos Fibrous Components Non - Fibrous Components Ceiling Tiles -3 EM 1917668 A Brown/white ceiling tile 100 ND 85 15 Basement 9X9-1 EM 1917669 A Tan adhesive 2 ND 0 100 B Gray granular cementitious material 2 ND 0 100 C Off white/multi-colored sheet vinyl 96 ND 0 100 Basement 9X9-2 EM 1917670 A Tan adhesive 1 ND 0 100 B Off white/multi-colored sheet vinyl 99 ND 0 100 Basement 9X9-3 EM 1917671 A Tan adhesive 2 ND 0 100 B Off white/multi-colored sheet vinyl 98 ND 0 100 Kit Floor -2-1 EM 1917672 A Black adhesive 1 ND 0 100 B Off white/multi-colored sheet vinyl w/ black fibrous 99 ND 75 25 backing material Kit Floor -2-2 EM 1917673 A Black adhesive 2 ND 0 100 B Off white/multi-colored sheet vinyl w/ black fibrous 98 ND 75 25 backing material TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-964-1"85801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI-ENV F: 303-077-4275 www.reilab.com Page 6 cf 7 Sat, Aug 19 09:00 AM - 10:45 AM Hawks Orange (Woods) vs. Spartans White (Klatt) GAME Parker, Iron Horse #3 Sat, Aug 19 10:45 AM - 12:30 PM All American (Romero) vs. Crush (Mitchell) Sat, Aug 19 10:45 AM - 12:30 PM Eagles Green (Beranek) vs. Denver War Eagles Fee Sat, Aug 19 10:45 AM - 12:30 PM Eagles Black (Broadrick) vs. Spartans Purple (Camarillo) * " time change Sat, Aug 19 10:45 AM - 12:30 PM Eagles White (Heshmati) vs. Hawks White (Reed) GAME Castle Rock, DCFG 1 GAME Aurora, Mission Vieio # 4 GAME Highlands Ranch, Northridge 3 GAME Highlands Ranch, Northridge 2 Sat, Aug 19 10:45 AM - 12:30 PM Spartans Gold (Stevens) vs. Eagles Green (Gibson) GAME Highlands Ranch, Northridge 1 Sat, Aug 19 10:45 AM - 12:30 PM Warriors Fire (Burtt) vs. Eagles White (Martinez) GAME Parker, Iron Horse #2 Sat, Aug 19 10:45 AM - 12:30 PM Warriors Chrome (Shaffer) vs. Hawks Orange GAME Parker, Iron Horse #3 (Woods) Sat, Aug 19 10:45 AM - 12:30 PM Colorado Peak (Maestretti) vs. Eagles Riptide GAME Aurora, Mission Vieio # 2 Franco Sat, Aug 19 10:45 AM - 12:30 PM BC Hot Shots (Burgess) vs. Colorado Jags (Page) GAME Aurora, Mission Viejo # 1 Sat, Aug 19 10:45 AM - 12:30 PM Spartans Black Comp (Sleesman) vs. BC Invasion GAME Aurora, Mission Vieio # 3 (Marquez Sat, Aug 19 10:45 AM - 12:30 PM Hawks Orange (Bachli) vs. Raptors Gray (Whitaker) GAME Englewood, Cornerstone 3 Sat, Aug 19 10:45 AM - 12:30 PM Spartans Gold (Galka) vs. Warriors Steel (Mimless) GAME Englewood, Cornerstone 2 Reservoirs Environmental, Inc. Reservoirs Emironmental QA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 386864-2 Client Earth Energy and Environment Corp. Client Project Number / P.O.: None Given Client Project Description: 3090 Reed Street Wheatridge Date Samples Received: Auaust 09. 2017 Effective January 1, 2015 Q:IQA000,WReservoirs Environmental QA Manual.doc Method: EPA 600/R-931116 - Short Report, Bulk ND=None Detected Turnaround: 2 Hour TR=Trace, <1 % Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: August 09, 2017 Client Lab L Asbestos Content Non Non - Sample ID Number A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R Kit Floor -2-3 EM 1917674 A Black adhesive 4 ND 0 100 B Off white/multicolored sheet vinyl w/ black fibrous 96 ND 70 30 backing material Kit Floor -3-1 EM 1917675 A Off white sheet vinyl w/ gray fibrous backing material 100 ND 50 50 Kit Floor -3-2 EM 1917676 A Brown adhesive 5 ND 0 100 B Off white sheet vinyl w/ gray/blue fibrous backing material 95 ND 65 35 Kit Floor -3-3 EM 1917677 A Off white/brown adhesive 5 ND 0 100 B Off white sheet vinyl w/ gray/blue fibrous backing material 95 ND 60 40 TEM Analysis recommended for organically bound material (i.e. floor ble) if PLM results are <1%. Brianne Neumann Analyst - Michael Scales Analyst / Data QA P 303-964-1986 5801 Logan Street Suite 100, Denver, CO 80216 1-868-RESI-EM F: 303477-4275 -renal, corn Page 7 of 7 12:00 AM First Comp Games Aug 19 Begin Sat, Aug 19 09:00 AM - 10:45 AM RMT (Cameron) vs. Colorado Jags (Page) GAME Aurora, Mission Vieio # 2 Sat, Aug 19 09:00 AM - 10:45 AM Warrior Red (Lohani) vs. Spartans Gold (Galka) GAME Englewood, Cornerstone 2 Sat, Aug 19 09:00 AM - 10:45 AM Raptors Gray (Whitaker) vs. BC Green (Salgado) GAME Englewood, Cornerstone 3 Sat, Aug 19 09:00 AM - 10:45 AM BC Black (Orozco) vs. Raptors Green (Steiner) GAME Englewood, Cornerstone 1 Sat, Aug 19 09:00 AM - 10:45 AM Untouchables (Martinez) vs. Crush (Madison) GAME Castle Rock, DCFG 1 Sat, Aug 19 09:00 AM - 10:45 AM EC Coyotes (Haves) vs. Prodigy (Simco) GAME Castle Rock, DCFG 2 Sat, Aug 19 09:00 AM - 10:45 AM Psyclones 04 (Kinder) vs. Eagles Green (Maloney) GAME Castle Rock, DCFG 3 Sat, Aug 19 09:00 AM - 10:45 AM Eagles White (Heshmati) vs. Warriors Scarlet (Farley) GAME Highlands Ranch, Northridge 2 Sat, Aug 19 09:00 AM - 10:45 AM Warriors Black (Troxell) vs. Hawks Blue (Wickstrom) GAME Parker, Iron Horse #2 Sat, Aug 19 09:00 AM - 10:45 AM Hawks Black (Surina) vs. Warriors Chrome (Shaffer) GAME Parker, Iron Horse #1 Sat, Aug 19 09:00 AM - 10:45 AM RMT (Reimers) vs. BC Invasion (Marquez) GAME Aurora, Mission Vieio # 4 Sat, Aug 19 09:00 AM - 10:45 AM BC Hot Shots (Burgess) vs. Spartans Black Comp GAME Aurora, Mission Vieio # 3 (Sleesman) Sat, Aug 19 09:00 AM - 10:45 AM Colorado Legacy (Hagardt) vs. Prodigy (Acree) GAME Aurora, Mission Viejo # 1 Sat, Aug 19 09:00 AM - 10:45 AM Eagles Green (Gibson) vs. Hawks Blue (Carpenter) GAME Highlands Ranch, Northridge 1 Colorado Department of Public Health and Environment Air Pollution Control Division — Indoor Environment Program — Asbestos/IAQ Unit 4300 Cherry Creek Drive South, APCD-IE-B1 Denver, Colorado 80246-1530 Phone: 303-692-3100— Fax: 303-782-0278 E-mail: asbestos@state.co.us ASBESTOS ABATEMENT PERMIT This permit is granted subject to Colorado Air Quality Control Commission Regulation No. 8, Part B, adopted December 21, 2007, and effective January 30, 2008, the Colorado Air Pollution Prevention and Control Act (25-7-101 or 25-7-501 et seq., C.R.S.) and the following provisions. It is only for the purpose of allowing asbestos abatement. ADDITIONAL PERMIT PROVISIONS: By performing work under this permit the abatement contractor agrees that the Division may revoke or suspend this permit should the Division find that the contractor: • has violated or has aided and abetted in the violation of 25-7-101 or 25-7-501 et seq., C.R.S. or Regulation No. 8, Part B, or an order of the Division or Commission, • has failed to meet any permit and notification requirement or failed to correct any violations cited by the Division during any inspection within a reasonable period of time, as may be determined by the Division, • has used misrepresentation or fraud in obtaining this permit, or, • has committed any act or omission which does not meet generally accepted standards of the practice of asbestos abatement. As a contractor, you may be subject to other licenses and permits, depending on the requirements of the county and municipality in which the work is being performed. The Colorado Department of Public Health and Environment, Air Pollution Control Division strongly suggests that you check with county and municipal authorities in order to determine any other local building/permitting requirements that must be met. THE ORIGINAL PERMIT MUST BE POSTED ON SITE AT ALL TIMES. Immediately notify the Asbestos/IAQ Unit of project modifications by fax (number above) or e-mail (address above) and the appropriate county health department by fax. Project modifications include changes in the scope of work or the scheduled work dates, etc. This asbestos abatement permit is valid beginning 9/4/2017 through 11:59 PM on 10/3/2017. The actual scheduled work dates are from 9/4/2017 through 9/8/2017. Approval issued on: 8/25/2017 Fee paid: $180.00 Record number: 130353 Check number: CC 2570 Notice Number: 17DE5204A Project Supervisor: Variance: None Fernando Vera -Jaime Comments: None Cerification No.: 9458 For the location specified below: Residential Throughout 3090 Reed St. Denver Denver County This permit has been issued to: Mile High Environmental Services, Inc. 9520 E. Jewell Ave Suite C Denver, CO 80247 Project AMS: Arthur Willden Cerification No.: 20138 Project Manager: Issued by: CA ci LL Oz Z O 1-- w U_W m J -j n. Q O U as CUJ Z J Oa Qo U? LJ- Oo ZU- Z = W~ m Z H a Q 2 m0 Q U Q V+ G WM iw W LL Q v a � O � � 3 N W U CC �ir U N � E O � E S > t15 j C Qv N � N C xX O u nm L RL E W a u 0 0E o v B W W V)=a � 3 O 0_ CD �o E �o y m to p rn U ^C' O E X U yC N f0 0 u C r- 0 U T C O U Od C C U N D C N C N 0 � $ T G cQ o E v a� E a (D O wL N O C O a $ ,� o. CL O t c O a U fA� L mooM. ° U d� ? m LN Y L N m. C O aE —° v 3 ccoC'm� y�cE'in L N O N O w N W U 0 > d 2o<a c cc�F- O N`L N U m c 10 r vim, m N ` 8 m._ W NL CD 2 mZ aU2;E I �' d aWi nGoo H N N } y C B0; y0 >o m a U =°U cn %°U v> >. ¢ CL o c �, d y d v p _. _. = 2 C m i U # = _ m O c 3 O W 'ad $ m N U r E L) F „� Y v Q 0 0 W ^ a O co N Q 0 d v U Q > V N O amici E ,, °' E E d o I Z v « :dCO 10 m a « m a o , 3 0 O U in iv ►- in iv a L a t t r g (D o a ti t q t um co Id H m CL N � N LO Cl)cb 8 C om N Q LL® j W a o C co a`rn m m v — o F- i/i tD E f- n 'o f0 Y 7 N C E ° dj �1 G$ C ED o O w w ¢ ` � _ � = o Q0 111 c iu m �~ ° �N m M U ti d C,� ~ �m c ov Q •-+ a cn O O a Q ° Z d C) N ° N d c N > V T E q . v r Z v V ac d Q C F- 01 U. ani d W d CD ti 0 U m w co U J n my ' CN 80 rn a o in c o r� m w UNO GOO O O CD co NM tQ ri �Q "' :. U to G1 'OC # M C O O N � t, m E > Q O U O U c d 0 U c m d a > a Q E L W CD > !v, E N `y O O m W MC m Q ❑ oy ? ai Zcl N °1 m W CN N ZE P co O # E#o c 'o _� ° Cn o� mW Z o� m Q L a 0 L 0 .-. ? L a C, a a a v a � O � � 3 N W U CC �ir U N � E O � E S > t15 j C Qv N � N C xX O u nm L RL E W a u 0 0E o v B W W V)=a � 3 O 0_ CD �o E �o y m to p rn U ^C' O E X U yC N f0 0 u C r- 0 U T C O U Od C C U N D C N C N 0 � $ T G cQ o E v a� E a (D O wL N O C O a $ ,� o. CL O t c O a U fA� L mooM. ° U d� ? m LN Y L N m. C O aE —° v 3 ccoC'm� y�cE'in L N O N O w N W U 0 > d 2o<a c cc�F- O N`L N U m c 10 r vim, m N ` 8 m._ W NL CD 2 mZ aU2;E 5366 Godding Hollow Pkwy EARTH ENERGY ENVIRONMENT (E3) Longmont, CO 80504 Local: 303.902-5851 Industrial Hygiene and Environmental Engineering September 7, 2017 Mr. Ivan Garcia Mile High Environmental Services Inc. 9520 E Jewell Avenue Suite C. Denver, Colorado 80247 Subject: Clearance Report Residential Property 3090 Reed Street Wheat Ridge, CO 80033 Dear Mr. Garcia: Following is the project completion report for the work area located at 3090 Reed Street in Wheat Ridge, CO 80033. The purpose of this report is to document this remediation project was successfully completed, and indoor asbestos amplification was not occurring in the work area. An Industrial Hygienist for Earth Energy Environment (E3) performed the remediation project completion inspection and testing procedures. The remediation work area (Interior Area) was visually inspected in order to confirm the scope of work was properly followed and completed. The containments were also visually inspected to verify breaches and/or defects were not present. Phase Contrast Microscopy (PCM) samples were collected in accordance with the National Institute for Occupational Safety and Health (NIOSH) method 7400 using cassettes (standard 3 piece, 25 mm dia., 0.8 um MCE filter) purchased from Zefon International, Inc. The asbestos concentrations in the containment were calculated as airborne fibers per cubic centimeter of air (F/cc). Table 1 provides a summary of the sample numbers, sample volumes, and calculated concentrations. The National Emission Standards for Hazardous Air Pollutants (NESHAP) clearance standard is 0.01 F/cc. Visual inspection confirmed that no asbestos -containing debris was observed in the work areas. The PCM clearance air sample results were all below the NESHAP clearance standard of 0.01 F/cc. Based on the information presented above, E3 concludes the asbestos abatement in the work area has been successfully completed, and the work area may be reoccupied after build back. PCM Air Clearance Page 2 of 2 TABLE 1: PCM CLEARANCE AIR SAMPLING RESULTS Date Unit/ Area Sample # Sample Description Sample Volume *Fibers/cc Air Clearance CL -090617-1 1050 0.001 at: CL -090617-2 Inside 1045 0.001 3090 Reed Street CL -090617-3 Containment 1025 0.001 September 6, in Wheat Ridge, CL -090617-4 1030 0.001 2017 CO 80033 CL -090617-5 1020 0.001 (Interior Area) - BLK-1 Blanks - BRL BLK-2 BRL *BRL denotes "Below Reporting Limits". The PCM Colorado Department of Public Health and Environment (CDPHE) clearance standard is 0.01 F/cc. Thank you for allowing E3 the opportunity to provide environmental services to you. If you have questions or require additional information, do not hesitate to contact me directly at (303) 902-5851. Sincerely, Eli Willden Ii Vr pl�- Certified Air Monitoring Specialist No. 20139 5366 Godding Hollow Parkway nt, CO 80504 EARTH ENERGY ENVIRONMENT (E3) Loa. 303.47780922 Industrial Hygiene and Environmental Engineering August 11, 2017 Mr. Jeff Wood Property Representative 3090 Reed Street, Wheat Ridge, CO Subject: Asbestos Sampling Results — 3090 Reed Street, Wheat Ridge, CO Dear Jeff: On August 9 2017, an Industrial Hygienist with Earth Energy Environment (E3) performed an inspection and asbestos sampling on a residential property located at 3090 Reed Street, Wheat Ridge, CO. E3 was retained by a property representative to determine if the accessible building materials within the property contain asbestos. SURVEY METHODOLOGY An industrial hygienist from E3 conducted the sampling. Materials were grouped into homogeneous sampling areas based on the material type. Among the interior building materials, fourteen (14) distinct homogeneous areas throughout the property were identified and sampled. Homogeneous Material Classifications ■ A preliminary walk through of the buildings was conducted to determine areas of materials which were visually similar in color, texture, general appearance, and which appeared to have been installed at the same time. Such materials have been termed "homogeneous materials" by the EPA. During this walk through, the approximate locations of these homogeneous materials were noted. ■ Following the EPA inspection protocol, each identified suspect homogeneous material was placed in one of the following EPA classifications: o Surfacing Materials - Sprayed or troweled on surfaces (walls, ceilings, structural members) for acoustical, decorative, or fireproofing purposes. This includes plaster and fireproofing insulation. o Miscellaneous Materials - Other non -friable products and materials such as floor tile and ceiling tile. o Thermal System Insulation - Insulation used to inhibit heat transfer or prevent condensation on pipes, boilers, tanks, ducts, and various other components of hot and cold water systems and heating, ventilation, and air conditioning (VAC.) systems. This includes pipe lagging, pipe wrap, block, batt, blanket insulation, cements, muds, gaskets and ropes. (These materials were not sampled as part of the survey.) Friability Classifications Friable and non -friable ACM's are defined as follows: ■ Friable asbestos -containing material: any material containing more than 1% asbestos, determined using PLM analysis, that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. ■ Category I nonfriable asbestos -containing material: asbestos -containing resilient floor covering, mastic or asphalt roofing product containing more than 1% asbestos as determined using PLM. ■ Category II nonfriable asbestos -containing material: any material, excluding Category I non -friable ACM, containing more than 1 % asbestos as determined using PLM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. ■ Regulated asbestos -containing material (RACM): (1) friable ACM, (2) Category I nonfriable ACM That has become friable, (3) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (4) Category 11 nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the materials in the course of demolition or renovation operations. Sampling and Laboratory Anal Bulk samples were collected by using various sampling tools (cutting tools, knives and chisels) to cut away or scrape portions of suspect building materials into zip -sealed plastic bags or sampling tubes. The individual samples were labeled by material type and location. Samples were analyzed by Reservoirs Environmental Laboratory located in Denver, CO. The laboratory maintains accreditations through the American Industrial Hygiene Association (AIHA), and National Voluntary Laboratory Accreditation Program (NVLAP). The analysis performed was EPA Method 600/R-93/116. INSPECTION RESULTS E3 collected at least the minimum number of samples from each homogeneous area necessary to meet all regulatory requirements for the quantity of material to be observed. Table 1 provides a summary of the homogenous areas. 31. _ i , Table 1. Homogeneous and Functional Sampling Areas. Material Material Physical Classification Samples HA Type Description Description Collected 1 Attic Debris Insulation A Black debris Thermal System 3 Insulation Insulation 2 Floor Debris Demolition A Off white/multi-colored debris Surfacing 3 Debris on Floors Materials A Brown gold/black resinous 3 Bathroom Walls material Surfacing 3 Walls B Off white granular plaster Materials C White plaster A Tan resinous material 4 Kitchen Walls B White plaster w/ beige/multi- Thermal System 3 Walls colored paint Insulation C Off white granular plaster A White plaster w/ pink paint Surfacing 5 Stair Walls Walls B Light pink granular plaster 3 C White/tan drywall Materials Light Green A White plaster w/ light green 6 Walls d Walls and paint Surfacing 5 Ceilings Ceilings B White/tan drywall Materials C Light pink granular plaster Back A White texture w/ pink paint B Surfacing 7 Bedroom Walls White plaster w/ pink paint Materials 3 Walls C Light pink granular plaster A White/pink flooring w/ white 8 Bathroom Vinyl Floors fibrous backing material Surfacing 3 Floors B Pink flooring w/ black felt Materials backing material Kitchen Surfacing 9 Floor Vinyl Floors A Green/multi-colored flooring Materials 3 (Layer 1) 10 Ceiling Tiles I foot x 1 feet A Brown/white ceiling the Surfacing 3 ceiling tiles Materials A Tan adhesive Basement 9 inch by 9 inch B Gray granular cementitious Surfacing 11 9x9 tiles floor tiles material C Off white/multi- Materials 3 colored sheet vinyl A Black adhesive 12 Kit Floor Vinyl Flooring B Off white/multi-colored sheet Surfacing 3 (Layer 2) vinyl w/ black fibrous backing Materials material A Brown adhesive 13 Kit Floor Vinyl Flooring B Off white sheet vinyl w/ gray Surfacing 3 (Layer 3) fibrous backing material Materials 14 Duct Wrap A Tan fibrous material Miscellaneous 3 Materials 411)a «c The laboratory separated and analyzed individual layers within each sample, if present. According to the laboratory analysis of the materials sampled, asbestos was detected in bathroom within the flooring and brown resin on the walls. The duct wrap was not sampled, but is assumed to be asbestos containing. Table 2. Asbestos Containing Materials Bathroom Black/Gold Resin Bathroom Flooring Duct Wrap Material Physical Asbestos HA Material Type Description Description Content Bathroom A Brown gold/black resinous material 15% 3 Walls Glue/Resin B Off white granular plaster Chrysotile C White plaster Bathroom Vinyl A White/pink flooring w/ white fibrous 25% 8 Floors Flooring backing material Chrysotile B Pink flooring w/ black felt backing material 13 Duct Wrap Insulating/ A Tan fibrous material Assumed Sealant Wrap Chrysotile Bathroom Black/Gold Resin Bathroom Flooring Duct Wrap CONCLUSIONS AND RECOMMENDATIONS According to the laboratory analysis of the interior building samples, asbestos was detected in the bathroom flooring and wall resin. The duct wrap was not sampled, but is assumed to be asbestos containing. A portion of the flooring (12 square feet) and the bathroom wall resin (15 square feet) were disturbed by the remodeling activities. The bathroom is therefore considered a minor spill area. Visual inspect indicates the spill is limited to within the bathroom. A minor spill response followed by remediation/removal of the asbestos containing materials by a Colorado Certified Abatement contractor is recommended. The Colorado Department of Public Health and the Environment requires any asbestos -containing material that is friable or will be made friable during demolition/renovation activities be removed prior to demolition or renovation. Any potential asbestos containing materials identified in the future or during demolition that were not sampled in this, or any other previous survey, should be tested for asbestos content or assumed to contain asbestos before being disturbed. If you have questions or require additional information, please contact me at (303) 478-0922. Sincerely, Art Willden Certified Building Inspector No. 20138 61r Attachment A Laboratory Report Reservoirs Environmental, Inc. Effective January 1, 2015 Reservoirs Environmental QA Manual T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc REI LAB RLM3rV17 r5 En T viron/7lenta/, Inc. August 10, 2017 Earth Energy and Environment Corp. 5366 Godding Hollow Pkwy Longmont CO 80504 Dear Customer, Subcontract Number: Laboratory Report: Project # / P.O. # Project Description: NA RES 386864-2 None Given 3090 Reed Street Wheatridge Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 386864-2 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, Jeanne Spencer President P:303-964-1986 F:303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 1 of 1 1-866-RESI-ENV www.reilab.com a ti Z_ J `Q r Z W 2 Z NON Z LU U) W N W w W J m H O LO C CL 3 LO O m O LO U E coC c y O m a Z E E N E U U C Z N a� a CV -0a a S E 0 ( Z 0 t"o O s m (n a W N i6 N � t0 y r m {ii V t L r (n N (D CD CD N C d 0 0 O co Ca) M Lu N H (OD N w CC o 3 a= m c a' W Z M Q W N Q O LO C 00 O LO N CD O LO U') 0 0 E coC cn CU -0 0' Q Z E E N U) U U C Z N a� a CV -0a O O E S E 0 ( Z 0 co c c c L (n a W a i6 N C j w ' LO LO 00 00 LO O O O O LO U') 0 0 O O a) 0) 0) O O O) O O O 00 CD O O Z � a co m (n m .aC LL d � cN J d N E `o O ai cv O co E C U O M CO O co C c Ln LO N N LO O O C) Q' LO C) Q' O Z O N N C N C E E O Q LL a T � � cu C O N a� E O� a W F- a LL O U w F o 0 0 0 0 0 0 0 0 0 Ln o 0 Z Z Z Z Z Z Z Z Z Z Z Z T) w 7 r O W O N 0 d 4 to c s U 7 f6 c 0 O 0 O 0 O 0 O 0 O 0 O N 00 O O LO LO W a C (0 O U dN U MnN Mn@ E a o ) 0) `� U) o -a 'p 'O 0 .a.• N to C N .� O O O O _O --F. a C6 a O U V (6 (4 2 N y >>> C m C@ cu C C m a) E a� E a� E a� `m c m c 0)cn 0 a a 0 U o U a v 3 s 3 t 3 t 3 .� -C t .a) C t >� m CD m > m O > J Q W a' Q Q Q Q Q Q Q co Q m Q Co U co I;t U') CO r N O) O 0(MO M M M d CMD CM O (O CM O CO CO C(0 (�D n r-- r- � r-- r� ti E rn rn rn rn rn rn rn rn rn 7 J W W W W W W W W W N M -0 N d O - (>0 - (>6 - (9 d E E U U U O O O r t s U U) Z Q Q QQ LL LL LL m m m Z O W u N m W .� m N O U m c O o � V m � � � a co m (n m � cN J d N a� `o O ai cv co E C 7 O M U C co m O O w N C O E E O N T � � cu C O N a� Q O� a W F- a LL U 2 � � Z W 2 Z O > Z W U) � U � W U) W w F. 2 § 0 L) 0. � z w m � a 2 0 � § © C c ■ \ o � m U) / 4&c§C-44M © c -0 a kw d 2 k n=�■2to 0 2 §§7a ■ w z n « w � g a 0 0 0 0 0 0 0 0 0 0 0 o z 0 0§ z// x 0 0 0 0 0 0 0 0 0 0 0= E / mm a 02 C) o o W o Of o o a o 0 0 Of r e e e e� ƒ& / E / 00ina0aa0a0ac £ ;§ z z z z z z z z z z z z z f �) 0 LU Q---........ ■ 0 � ■ ) � 2 J }} a LO z o= r\\ o 0 o r r o N 04 LO a w CO LO_ N n# 0- \ 2 \ \ \� k /§ E) £ k k \ o Co Co k \ � E R R E 2\/ƒ 7 ®t @ 7 ) @ 7\ ` t @ e t e / 7 Q / Q / \ a x=70= � cu C: _ � c 7=/0- cna 2 = E /\0 8 Fc" 0\f«�3: u<»uIx<Eo<E<Io<c<=o Cl) (.0 \ / k / § \ \ \ \ \ \§ w 3 w w w ? 9 9 \ 2� \ \\ \ \E E \ \ 2 ] 2 2 2 \\ d U z_ J a z W 2 z O�y LL z W NNN 1.1. W U) W w C j +N+ 6 Y O O Q 3 O O 0 00 0 0 w ° U f 0 0 +' O m a 0 0 E I c 0 � c o O a C W t N t0 N e 0 cn N (A N we C N O O C M W Of N L H w t�D o a= 5 c m W Z M Q W N Q C j +N+ 6 O O O O O a 0 O O O O o 0 0 w ° 0 0 0 0 0 0 0 0 a) 0 0 Z E m c zoo a E m Z N d c- a E E -0 d O U O U) co U UD D H C j +N+ 6 O O O O O O O O O O O O 0 0 w ° 0 0 0 0 0 0 0 0 0 0 0 0 Z .2 C LL a E O U O O c o x x O O OC) O O O O O O Z w O 0 w C 0_ QE E O U +; o D D Din 0 0 D D 00 00 = y m. Z Z Z Z Z Z Z Z Z Z Z Z i4+ i C O W V........... N O w N d m c_ � t LO Lo O O O O U') U') � V) O O (n d ° Lo to LO �t O M (fl CO N CO C @ O C5 U Q j U a O . C L N a. a C C C Q .c m aco OL a) m N N `v' d O m Y 4) m 3 m rn o a Z5 ar aL cu .Q m Co O ` 3 f6 .0) co c 3 3 c 3 � 3 3 c 3 U N m? c mCo ? co co 0 Y m m Y c m Y m m m Z c_aac 2a ca ca ca a, Q m m a °' m m m � 2 a - a :EL:Em J > > _ J m> J m J rn J > m Cn �Q>- WX ¢ m Q m a m ¢ m a m ¢ m Il_ 00 0) O N co 'IT LO LO LO y (0 CD CD O d1 O O O O) Cn 7 J W W W W W W W N M M N M 0) m c c c 0 0 (7 U (A Z (A (n U) U) Z O W U 55 m W= d LL A (i 2 � � 2 w 2 2 O > 2 w U) O � w cn W w E W\ / °>q 7aE CD\/ @S® k/$ ,E z C t o u � © / c ■ ° m o � co � CMm 4cc§®m © e a Go > C) m w 0 2 m § 2 a ■ w z n « w \ § \ $ / 3 E ( g k z R af E 2 ƒ�E \ I I $ 0 U) 2 to = ± 3 3 \ 5 D �0002� CN § k k I = C-4 « § a o= 00 0 0 o r o 0 0 0 0 0% z/c o = o o w o o 0 = 0 0 0 CLE / § S= f� 0 2± o o w o f of o 0 0 z\§/� /ƒ E E / a moo C3 0 0 coo coo 2 ;§- z z z z z z z z z z z z f �g o w Q........... 0 ■ 2 � 2 & /} S? S- g 2-? 8 2 2 2 \CL � L \ M- U) k k\ c\ c q= \ ff \ -7 _ _ M _ _ 2 \ = _ % 3 £ } \ D k\ 0 k\ k � -D - = 7 = 0)= 0\\\ c q c�n c� q c�# G CL 3® 0— M a M °±� c c$ 2 m 12 c± 2{; 2 \ \ 0) \ \ 0) \ \ 0) \ \ 0) _<»±Of<=o<=o<=o<=o .0 / / / \ § \ k \ k \ g w w w w \ \ \ IT r = o \ \ \ k 4 4 I E w E \ \ \ § § 2 z 2 £ I 3 \\ a V Z J Q H Z W NZ I.f. Z W U) W N W w E N 0 LU ��- mQ N O aUi o E v O aj II aN 0 O Q Z 2 O � � Z F- F -- 0 - C OC a O I- a E . o O m U E � a0i c � O � a Q E U U a) a) ct O 0 O a a O C m j N 0 CoO w r C Wm a) a) @ Co C m T d T T T N 0�1 C U) N CD N co co CO C> w d O O M w fn C, N m o p O W p a.= w w Z M Q w N Q C OC a O I- a E . o c ' E � a0i c O OOF Z p Q E U U a) a) Z 0 O a a o EEE 0 CL CL Co 0 CoO r C Wm a) a) @ Co G_UUUO2H C OC a I- O 0 O OOF LO O O O r - Z r r r L C LL d E 0 U C: O to Nc O O O O UO LO O O O Ln 0 Z U) 0 a) v ao m O c Q IL d E O U deooccIn 00000 Z Z Z Z N Z Z Z Z Z Z 17 °' > :) O O LU Vl O N d d c_ s � V .0 o o U) U) O O CO N O 0 O 0 O 0 O 0 O 0 d Ln m'IT U) m E m C � C Y U � CE O_ C N O O 3 m U O_ O in a) D 7 7 U) C (UO CT Q .o o `0 E w O O O 0 0 Co M a> a> C 7 m U U N N m m C c 3 c c 3 `0 3 Q- CL o 0 0 a a) M M O UY N Y N Y `O o c c_ Q •a f E E E 3 3 0 a a N 0 Q Q c c c c c L L> L C N a) m J m J > d O Z O Z (D (D C7 O 0o O c0 JQ>- wW ¢ m ¢ m a m Q¢ Q Q (O m O N M IT LO CO h U7 LO O (O CO (0 CO Q0 Cfl (D y Co ((O ((o CSO ((O co to (D �o (^O J_ w W W w w w w w w w N M O N (9 (0 0 0 U U N N Cl) 'D O O O O O O — CV F- F- +. a s m m tL LL U -o O O O m m CE EY Y L L .L-. L.L _o LL _O LL C C U co Z m m m m m Y Y Y U U Z O Ly N m LU 'm J 6 Z J Q Z W 2 Z O z W N� I.L W N W w c Q m Cm cc W y 0 tD 01 O 0 O d 0 0 U a R J a J z 0 � c . O L U E u)i o z0 E t5 t5N Z o O O E o••ddcn-6 W (6 N C j N Y 0 0 0 Q 7 0 LO O m U •C N O m a Z coV c c C C j R O d t c w � N E U N M N co C d 08 O M W W L (A t t�0 d 7 01 0 3 CL w W z in Q W N Q 0 � c . O L U E u)i o z0 E t5 t5N Z o O O E o••ddcn-6 W (6 N C j N 0 0 0 0 0 0 0 0 LO O Ln O pN N 1—:1N Z .L] C a E O U to .. c O Q p LO O O O O O O O O LO O LO Zin p O`er W � c Q IL a O U =y �.. z z z z z z z z z z z z r > r 0W O N O N W .yam N Q 7 (6 e O N CN04 N N C 0 0 U U (6 f6 L L c c c c c rn a Q O L _ w L w L (b L U) L U)a) a Z.= c 0 N d N p EO O O O _O .� V U OU OU U - p •c - •` N @ U m .3 m M y '� _ .> > CD > a� E E 'N E E E cuE L� 3-C o -C s -? E m m O, L @� cm 3 m p�3 m 3 m 3 arc -tc 3 U 0 3 U p C f6tr: c C m t�°00 H� If°0 m0.2 m02 J Q>- W Of Q Q CO U Q CO Q CO Q CO Q m OJ O O N Cl) d �O CD cc (D (D O ti O) O O O O O) J W W W W W W N M M O O O O N N .2 E E E O O _ p O d FL LL UfnZ U m m m Y Y Z o w Y U5 N LN ro (i Z � � 2 W 2 2 O � > 2 W U) w Z5 � W U) LU w j j \ § z w m � E -\ _)) )=0 oae k\/ °SA 0 < 2}\ z o \\ � E/ . \ % % 0 .2 % / ± , L: � °CL < E . ■ $ z \ o / r E E � II$22$ U)y 2 £ 3 3 3 k I a 7 ) eo§ 0 4oc§®$ o ® co CC d > % q ui 2 J O S;§ < 0 U) M § 0 g § 0. = ■ w z M « & C « o \\ \ E/ M§§ \ % % M .2 % / ± , L: ? UO) ( z / < E 2 t k $ z 7 7 = / r E E \ II$22$ U)y 2 £ 3 3 3 k I a w00002 B 0 o \\ E/ M§§ /E M /0 ƒ\ E / 0.2 , c E S0 g0 B zo=� < E / MM—ZZ z z z z z > ) w § Q........... ■ 2 W � � J } co't+ / ® 6 6 ƒ ƒ » / E ) c / f E c 0 .0 / ) G _ 5/ c o \ \ 2 = ` \£ 3 3 §g / c _& n __ $ __ 7 2 ƒ ƒ D § b \a a \ \ \ / D § k ; E ® f § _ cn % / \ \ 2 f / f -le =cac3=� R R R R R § <_ <<_<_ \_ \ }_ � _/ j ww w C? — � n § \ Cl) \ 2 Q » b b b SEE/ §22 2 22 2 o \\ Earth Energy Environment (E ) PAY APPLICATION Services For: Jeff Wood Property Representative 3090 Reed Street, Wheat Ridge, CO INVOICE NUMBER AUG.11.2017- Reed INVOICE DATE Aug 11, 2017 PROPOSAL NUMBER Verbal PURCHASE ORDER NUMBER NA TERMS 130 Days Item Work Description Rate Total AMOUNT 1.0 Services at 3D90 Reed Street, Wheat Ridge, CO Wednesday, August 9 2017 - PLM Sampling Labor and ReportingFIXED $ 1,200.00 $1,200 DIRECT ALL INQUIRIES TO: MAKE ALL CHECKS PAYABLE TO: PAY THIS AMOUNT $1,200 tuian—Uar,.Com farm tnergy tnvtronment ATTN: ACCOUNTS RECEIVABLE PO BOX #348 FREDERICK, CO 80530 THANK YOU FOR YOUR BUSINESS! ;IXG FlvT the 6 SP LPC jiiG;�� � � 1 it � a � A A71T'iL. fix✓ ` # P11-54. L apical AGED I_-4Cr Installation � ,i � r, i'' t�fa �:-Tt, �, l.-. �- VAT6 c4 - - � 11�K t� L,/L— 5S :a t� %1 J1' tK� TO P�e c 0 LU l 1Lv 'AFF—fir 5th .J!>y CJX"t_I~S THA t Cecil Rickstrew, P.E. 1627 Glen Moor Dr. Lakewood, Colorado 80215 'To: Jeff Wood EM: jeffwoodwoodwork@gmail.corn Invoice (Phone #: 303-668-2382 E-mail: Cecil@ecsidenver.com Date: 7-16-17 Invoice: 300-17 For engineering services on 3090 Reed St., Wheat Ridge 4 hrs. engineer's time @ $85/hr for inspection trip, inspection and stamped report `>3 s: This bill is rendered only as an accommodation. Terms are net cash and payable upon presentation of invoice. Unpaid invoices accrue interest at 1% calculated on a daily basis. Please write the invoice # on your check or send a copy of the invoice with your payment B2, s0 7 2 j Invoice Cecil Rickstrew, P.E. 1627 Glen Moor Dr. Lakewood, Colorado 80215 To: Jeff Wood EM: jeffwoodwoodwork@gmaii.com cor engineering services on 3090 Reed St. Phone #: 303-668-2382 E-mail: Cecil@ecsidenver.com Date: 7-23-17 Invoice: 311-17 Revised beam location between kitchen and living room No chart:: Reframing of two bedrooms flush beams above ceiling 2 hrs @ 535/hr SI 7/ This bill is rendered only as an accommodation. Terms are net cash and pavane uoi k presentation of invoice. Unpaid invoices accrue interest at 1% calculated on F, daily oasis. Please write the invoice # on your check or send a copy of the invoice with your payment CeciURickstrew, P.E. Ph #: 303-668-2382 1627 Glen Moor Dr. E-mail: Cecil Pecsidenver.con Lakewood, COWQ215 Ju|y23'2O17 Jeff Woods EM: jeffwoodwoodwork@gmaii.com RE: 3090 Reed St., Wheat Riage This letter shall serve as this engineer's field inspection report of7-19-17xvkhrespect to-Jhe above referenced home. TheinspeCtionrevea|edthenevvdropbearnpnDposedbetvveenthekitchenandUvingroonnhrr rennovai of the existing vvaU was not over the bearing vvaU b2|Ovv as detailed in nnyoiQinal repon,put the wall previously bearedupon the floor joist. Due tosuch, the drop beam needs to be snifter 3' to east and a column of two 2x6 provided on the north side of ,.-he stair well as shown in the attached elevation � Secondlv. the wall between the two bedrooms which is to be removed and present!-,, is tc be replaced with flush beams mounted in the ceiling are shown on the attached oave wit-, 7ne required ��dibOna|support for such inthe existing floorbe\ovv. UndertakinR the modifications as referenced above will leave the home structuraliv 5ound in the area ofmodifications. Cecil Rickstrevv P.E. -4- -S L cr CEJ ; 7�r^-- RN6F1Z5 I y! fkLH TD fIOLU.7 .' ,v LPC Typical ACE installation Q- 0 ell 0ell ( Rei*. ;30''J i %2... „0 Z 'i L �3> -�i S?u�S}, li 't "a a, \X- rte, �T& G vA-T JA�*I* L ULL At CWPA##Y -Kip r N Lot i8 ;,4ik,.rFA -,A"f"J&,fi" -e ."#4„. cajolfer3on ovAr* 40 7&5 A - Ile# 1S ti Iva mwwsuo-ug. NOW Cfwtw^ft T"Al TWO fs via Two$ UU.” Of It* Ufttwv "sc,wifto "Oft "UT Two ftw**Awy LMSAM " %**" "04W T"At TW40 4" "o "C*"Cj#,Afwrs om 1 0 PrInVIV", r"I "W" A imo v"MS t'"ft"C4 up 6 ***won *W40 40, Waft A%" OR VOW*yt P*ts&*tVfAy &C#O$S s 40 9 r3t3 04 Of AOY 91-AWW4T ww,*GU-T 00 #**To 00 S" Moon *a* n#Aj t"M AM "0 SUMMM 1 A Ov SAGO Pt*ftMl #Mt" A# INS40AIM 80 ""s f"T "M "Wf" IS &Wkft ftW "IS AS*" STAVU tWOM O"It A" NO "WX "t#@ftftOW,# NkWO "OkIft, 30 � 0 ge-eo City of Wheat Ridge uilding �Src�sS f.J s N�103.� 2'sx3'�a APPROVED.- BY: CLAIL&-f- D ATE: COMMFNTS: ..a viel'y rcq v AI City of CO ge MMUNITY DEVELOPMENT APPROVED Reviewed for Code Compliance Plans Examiner Date rmit a approval o(p— spe Ileo " Validkv of oersss : iM issuance o(o D< violation to computaliom shot) not be a permit fa, or an opWoval of. on any of the Provisions o/ the bot)ding code or of any City ardvronces. Permits presuming to give ourhmity to violate of cancel Me provisb^s of the "60" codes or other ordinances of the city shat) not be valid, Z"5 Y, I( BAST: NOT APPROVED AS AN INDEPENDENT DWELLING UNIT. 3.7 , what v, tj ('r ���� �17 Ivson v) vu i t LI (� 3-e �o ✓ t pe Hyl of i -e.. 1) N 1) � is /�,% l)1-1 151 1) t,1 _ ,- Fnc) f� r. 1) N 1) � is /�,% l)1-1 151 1) t,1 36-)"q(3 � ee� -2�'7 I City of Wheat Ridge � ,lc 4 �-r{ V fS-MtY-5 D 47 1 t 7 �07 Fm o /cc De rec-ro- -7--o C C P e- vr,wo KvN-, WAILS 0\ m DH 7'XI F I R,3off, v -) t4ppce- Ploor- Ig , Pf , Rrmojll- -e- -fog ncity at 4 Alcfj 10 Wheat 7 dg Building Divisor, ,on ce: JEFF added Due 31. c.., Run menus B.... mi seat a it Subbech RE excess Request Re 3 09 0 Re ed Sires t mi Thursday, knees Re r 3 0, 2 017 7 17 00 AM HI oerek The following sub needs to updatemeb information before mepent can be Isaed� Grateful Electric—needs to update his licensing and insurance I have removed the previous contractor. If any work Is added to the permit a revision will need to be permitted prior to the start of any additional work The total due on the permit is $40,000.00. This includes a double permit fee for the stop work order Total Valuation $40,000.00 Perm[ Fee $614.55 Use Tax :$840.00 Story Fee $61455 Total Dun $2 069 10 Thanks, Kim Cook dhmuan offline Phone: 303 See Sees vY hM Mplald From: Berth Thiess lmeltoderekthuss@gmallaoml Sent Wednesday, November 29 201710'03 PM To: Kimberly Cook <kcook@clwbeatddge of us> Cc: Jeff Wood q fiwoodNoodNOM@gmel. cii Dave Bosman <dbnssman@ i wheatddgeeo us>, Russ Hlgglns <rhlgglns@elwheatddge of use, Brian ranks QrtaNlf@clwbeatrldge of use, Scott Brink<sbank@i wbeatdtlgemus> Subject: Re Access Request for 3090 Reed Street Kim, Thank you for your prompt reply. I did forward an email to Bran and yourself around 3 per today from the contractor on the current permit. I believe he is going to email you directly as well. Yes, we are all squared away on subs. The electrician will be Ryan with Grateful Electric and the plumber will be Rich from United Plumbing. Should any other work be subcontracted they too will be appropriately licensed by the city. I will be in tomorrow at some point to pick up the permit. Do you happen to know how much the permitting fee and use tax will be? My contract is cost plus, performance based, and I do not have an estimate of costs at this time. Therefore, I assume you will be using the standard valuation formulas or the contract values submitted by the prior contractor to determine the project value. Once the permit is issued, I would like to do a walkthrough with Brian or whomever is in charge of inspections at this point in time, so we are all on the same page going forward. Thank you for taking care of this in a timely manner, it does not go unappreciated. Regards .......... Derek Derek Thiess President The Mystinfield Group, He 720.421.8174 cell 307.200.8964 office mvstinfield.houzz. com On Nov 29, 2017, at 4:43 PM, Kimberly Cook QkcookAci.wheatridge.co.us> wrote: Hi Derek, Just wanted to let you know, the permit is ready for 3090 Reed Street for pick-up. Were you able to get something in writing from the previous contractor regarding changing the GC on the project? Also, were we all squared away on the subcontractors? Thanks, Kim Cook Permit Technician Office Phone: 303-235-2876 <image001.jpg> From: Derek Thiess[mailt0:derek.thiess(cDgmail.coml Sent: Wednesday, November 29, 2017 12:10 AM To: Scott Brink <sbrink(cDci.wheatridge.co.us> Cc: Jeff Wood <jeffwoodwoodwork(cDgmail.com>; Dave Brossman <dbrossman(cDci.wheatridge.co.us>; Russ Higgins<rhieeins(cDci.wheatridge.co.us>; Brian Tardif<btardif(cDci.wheatridge.co.us>; Kimberly Cook <kcook(cD ci.wheatridge.co.us> Subject: Access Requestfor3090 Reed Street Scott, Please see the attached letter, on behalf of Woodwork Realty and Jeff Wood, regarding the driveway to be installed at 3090 Reed Street. Please feel free to contact me should you have any questions or concerns. Regards... Derek Derek Thiess President The Mystinfield Group, LLC 720.421.8174 mobile 307.200.8964 office derek.thiess(c gmail.com Confidentiality Notice and Disclaimer: The information contained in this e-mail may contain privileged and/or confidential information intended only for the use of the individual or entity named above. If you are not the intended recipient, you are hereby notified that any dissemination, distribution, copying or other use of this e-mail is strictly prohibited. If you have received it in error, please immediately notify us by telephone (307 200 8964) or e-mail, and delete this message. Although this e-mail and any attachments are believed to be free of any virus or other defects that might affect any computer system into which it is received, it is the responsibility of the recipient to ensure it is virus free and no responsibility is accepted by The Mystinfeld Group LLC, or the Sender for any loss or damage arising in any way from its use. From: Derek Thiess To: Scott Brink Cc: Jeff Wood; Dave Brossman Russ Hiaains: Brian Tardif Kimberly Cook Subject: Amess Request for 3090 Reed Street Date: Wednesday, November 29, 2017 12:10:42 AM Attachments: 17.1128.3090 BRINK LETTER.tddtrn.docx Scott, Please see the attached letter, on behalf of Woodwork Realty and Jeff Wood, regarding the driveway to be installed at 3090 Reed Street. Please feel free to contact me should you have any questions or concerns. Regards... Derek Derek Thiess President The Mystinfield Group, LLC 720.421.8174 mobile 307.200.8964 office derek.thiessAgmail. com Confidentiality Notice and Disclaimer: The information contained in this e-mail may contain privileged and/or confidential information intended only for the use of the individual or entity named above. If you are not the intended recipient, you are hereby notified that any dissemination, distribution, copying or other use of this e-mail is strictly prohibited. If you have received it in error, please immediately notify us by telephone (307.200.8964) or e-mail, and delete this message. Although this e-mail and any attachments are believed to be free of any virus or other defects that might affect any computer system into which it is received, it is the responsibility of the recipient to ensure it is virus free and no responsibility is accepted by The Mystinfield Group LLC, or the Sender for any loss or damage arising in any way from its use. November 28, 2017 Re: Permit p 201707245 -3090 Reed Street The Mystinfield Group, Ilc General Contractor for Project 5555 W. 69�h Avenue Arvada, CO 50003 307200.5964 On behalf of Woodwork Realty 19453 E. Tufts Circle Centennial, CO 50015 303.615.5355 To: Scott Brink, Director of Public Works From: Derek Thiess, President of the Mystinfield Group, Ilc on behalf of Jeff Wood, and Woodwork Realty, Owner of 3090 Reed Street. Subject: Access to new Garage Mr. Brink, The purpose of this letter isto respectfully seek review and approval from yourself and the Public Works Department to install a driveway which shall serve to access the newly constructed garage built under the above referenced permit. The lot is a corner lot, and the garage is located in the northeast corner of the property, and sits 12.5 feet from the north property line as approved perthe variance referenced in Case No. WA -17-09 / Wood, and granted by Kenneth Johnstone on 8/31/17. Therefore, the driveway access will need to cross the city right-of-way and possibly require the issuance of an access permit and/or right of way permit. 311 street drains to the east and crowns, subsequently causing sheet -flow across the driveway. The driveway shall be constructed to slope from west to east, in the right of way area at a minimum 1% slope, and slope from the street towards the garage at no less than 3%, for the first 10 feet. The driveway shall then continue up to the garage at a constant slope, not in excess of 14%. Furthermore, the driveway shall be constructed with a minimum thickness of 6 inches using 4000psi air entrained concrete which shall be placed upon a properly prepared and compacted sub -base free of loose and/or organic materials containing a minimum of 6 inches of % inch, class 6, recycled, concrete road -base, compacted at 95% of its optimal dry density, using a suitable mechanized compaction device. The sub -base shall be proof rolled until solid and free of loose materials and/or soft spots priorto application of the base materials. If handheld compaction equipment is used a minimum of 4 passes per 3" maximum lift shall be performed. Thank you for taking the time to review our access plan. Please let us know if there is anything that you would like to see done differently. It is our understanding that we will need a form inspection priorto pouring as well as a final inspection. Please let us know what the process is or if you require any deviations from our plan. Respectfully, Derek Thiess President The Mystinfield Group, LLC CC: Jeff Wood, Dave Brossman, Russ Higgins, Brian Tardif, Kimberly Cook CC: Jeff Wood, Dave Brossman, Russ Higgins, Brian Tardif, Kimberly Cook From: Derek Thiess To: Brian Tardif Cc: Kimberly Cook; Jeff Wood Subject: Fwd: 3090 Reed St. Date: Wednesday, November 29, 2017 1:35:15 PM Brian, Please find attached, the letter from James Macias of Affordable Remodeling Solutions, Inc, requesting removal from the permit for 3090 Reed Street. I am assuming I can now come pick up a permit. Please call me to confirm this is the case so I can come pick up and pay for the permit. Do you have any idea how much the permit fee and use tax are? Thanks...... DEREK Derek Thiess President The Mystinfield Group, LLC 720.421.8174 mobile 307.200.8964 office derek.thiessnamail.com Confidentiality Notice and Disclaimer: The information contained in this e-mail may contain privileged and/or confidential information intended only for the use of the individual or entity named above. If you are not the intended recipient, you are hereby notified that any dissemination, distribution, copying or other use of this e-mail is strictly prohibited. If you have received it in error, please immediately notify us by telephone (307.200.8964) or e-mail, and delete this message. Although this e-mail and any attachments are believed to be free of any virus or other defec is that might affect any computer system into which it is received, it is the responsibility of the recipient to ensure it is virus free and no responsibility is accepted by The Mystinfield Group LLC, or the Sender for any loss or damage arising in any way from its use. On Tue, Nov 28, 2017 at 8:23 PM, Jeff Wood <effwoodwoodwork4gmail.com> wrote: Here is the letter We need to get him off of the permit From: "James Macias" <jjmacias67(cihotmail.com> Date: Nov 28, 2017 12:20 PM Subject: 3090 Reed St. To: "ieffwoodwoodworknamail.com" <ieffwoodwoodworknamail.com> Cc: Hello Jeff- please remove my company: Affordable Remodeling Solutions, Inc as the GC from the permit at 3090 Reed St. Wheat Ridge. CO. I will follow up with city in a day or two to confirm this has been done. Thank you, James Macias Get Outlook for Android ce: JEFF added Due 31. c.., Run menus B.... mi seat a it Subbech RE excess Request Re 3 09 0 Re ed Sires t mi Thursday, knees Re r 3 0, 2 017 7 17 00 AM HI oerek The following sub needs to updatemeb information before mepent can be Isaed� Grateful Electric—needs to update his licensing and insurance I have removed the previous contractor. If any work Is added to the permit a revision will need to be permitted prior to the start of any additional work The total due on the permit is $40,000.00. This includes a double permit fee for the stop work order Total Valuation $40,000.00 Perm[ Fee $614.55 Use Tax :$840.00 Story Fee $61455 Total Dun $2 069 10 Thanks, Kim Cook dhmuan offline Phone: 303 See Sees vY hM Mplald From: Berth Thiess lmeltoderekthuss@gmallaoml Sent Wednesday, November 29 201710'03 PM To: Kimberly Cook <kcook@clwbeatddge of us> Cc: Jeff Wood q fiwoodNoodNOM@gmel. cii Dave Bosman <dbnssman@ i wheatddgeeo us>, Russ Hlgglns <rhlgglns@elwheatddge of use, Brian ranks QrtaNlf@clwbeatrldge of use, Scott Brink<sbank@i wbeatdtlgemus> Subject: Re Access Request for 3090 Reed Street Kim, Thank you for your prompt reply. I did forward an email to Bran and yourself around 3 per today from the contractor on the current permit. I believe he is going to email you directly as well. Yes, we are all squared away on subs. The electrician will be Ryan with Grateful Electric and the plumber will be Rich from United Plumbing. Should any other work be subcontracted they too will be appropriately licensed by the city. I will be in tomorrow at some point to pick up the permit. Do you happen to know how much the permitting fee and use tax will be? My contract is cost plus, performance based, and I do not have an estimate of costs at this time. Therefore, I assume you will be using the standard valuation formulas or the contract values submitted by the prior contractor to determine the project value. Once the permit is issued, I would like to do a walkthrough with Brian or whomever is in charge of inspections at this point in time, so we are all on the same page going forward. Thank you for taking care of this in a timely manner, it does not go unappreciated. Regards .......... Derek Derek Thiess President The Mystinfield Group, He 720.421.8174 cell 307.200.8964 office mvstinfield.houzz. com On Nov 29, 2017, at 4:43 PM, Kimberly Cook QkcookAci.wheatridge.co.us> wrote: Hi Derek, Just wanted to let you know, the permit is ready for 3090 Reed Street for pick-up. Were you able to get something in writing from the previous contractor regarding changing the GC on the project? Also, were we all squared away on the subcontractors? Thanks, Kim Cook Permit Technician Office Phone: 303-235-2876 <image001.jpg> From: Derek Thiess[mailt0:derek.thiess(cDgmail.coml Sent: Wednesday, November 29, 2017 12:10 AM To: Scott Brink <sbrink(cDci.wheatridge.co.us> Cc: Jeff Wood <jeffwoodwoodwork(cDgmail.com>; Dave Brossman <dbrossman(cDci.wheatridge.co.us>; Russ Higgins<rhieeins(cDci.wheatridge.co.us>; Brian Tardif<btardif(cDci.wheatridge.co.us>; Kimberly Cook <kcook(cD ci.wheatridge.co.us> Subject: Access Requestfor3090 Reed Street Scott, Please see the attached letter, on behalf of Woodwork Realty and Jeff Wood, regarding the driveway to be installed at 3090 Reed Street. Please feel free to contact me should you have any questions or concerns. Regards... Derek Derek Thiess President The Mystinfield Group, LLC 720.421.8174 mobile 307.200.8964 office derek.thiess(c gmail.com Confidentiality Notice and Disclaimer: The information contained in this e-mail may contain privileged and/or confidential information intended only for the use of the individual or entity named above. If you are not the intended recipient, you are hereby notified that any dissemination, distribution, copying or other use of this e-mail is strictly prohibited. If you have received it in error, please immediately notify us by telephone (307 200 8964) or e-mail, and delete this message. Although this e-mail and any attachments are believed to be free of any virus or other defects that might affect any computer system into which it is received, it is the responsibility of the recipient to ensure it is virus free and no responsibility is accepted by The Mystinfeld Group LLC, or the Sender for any loss or damage arising in any way from its use. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 d 3 &W SITE Job Address: 3D 96 W;& S f Permit Number: o %O% A16' ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Dater �I I� l Inspector: /I1 ! # DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: .� / ��— Job Address: o Permit Number: ®/%O 2 'i IV (• w. ,T�' ' ❑ No one available for inspection: Time r)1 AM Re -Inspection required/"Yes fro When corrections have been -m call for re -inspection at 303-234-5933 Date: ' % 7 Inspector: ) "6//�� DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE 1� Inspection Type: -�tJ A ALM Job Address: ' .!� Permit Number: ADZ 70 72 LlNo one available for inspection: Time _ AM/P M� Re -Inspection required;r Yes ,,No When corrections have been made, call for re -inspection at 303-234-5933 Date: / 7' 7 Inspector: DO NOT REMOVE THIS NOTICE OF W tns yF67 0 ss 3 h 'nspeotio ,/� OOe ��S*bec1 per ob qaa Type; SAF�T °312 Mit JV, SS /ONNO%, P S r No one available re U for /nspeetio . Re-Inspection4 re,,. n. T. Yes me *When corrections have been NO 7 L pate:forre'nspecti M DO NOT nspector .] o,dr3 R , t„_, yi s CITY OF WHEAT Bui►din RIDGE (303 9 Inspection Division (303 234-5933 /nsinection 235-2855 Office . line (303) 237-8929 Fax INS P ECTION NOTICE Inspection Type: Job Address: Permit Number: 0 6 B 40 4L._ - IJ NO one available for inspecti Re -Inspection re quiredAM/pM: �� No �ate: When corrections h ave been made, 'for re-inspection at--&/ �/303- 2- 34_Sj33 Inspector: Op NOT,gE T H/S IVpT/CE 1 City of Wheat Ridge Residential Roofing PERMIT - 201701786 -1�9� PERMIT NO: 201701786 ISSUED: 06/09/2017 JOB ADDRESS: 3090 Reed ST EXPIRES: 06/09/2018 JOB DESCRIPTION: Res re -roof: Install GAF Timberline 30 year asphalt shingle 18 squares. REDECKING. *** CONTACTS *** OWNER (303)234-0526 TRICKLER DEWIGHT ORRIE SUB (303)980-6463 Anthony Collins 170247 Hometown Roofing & Exteriors *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,032.25 FEES Total Valuation 0.00 Use Tax 126.68 Permit Fee 156.75 ** TOTAL ** 283.43 ----, *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€l"s installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201701786 PERMIT NO: 201701786 ISSUED: 06/09/2017 JOB ADDRESS: 3090 Reed ST EXPIRES: 06/09/2018 JOB DESCRIPTION: Res re -roof: Install GAF Timberline 30 year asphalt shingle 18 squares. REDECKING. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the leg,al owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermIt. I further attest that m le ally authorized to include all entities named within this document as parties to the work to be performed�rf� that all work tq performed is disclosed in this document and/or its' accompanying approved plans and specifications. r ,, Si nature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing, and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date %Z!!JJUUDJV%:-.-r"A4_ REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Antoinette Kulick From: no-reply@ci.wheatridge.co.us Sent: Friday, June 9, 2017 7:11 AM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those` documents at the time you are issued your permit. Permits are currently being l processed within 3-5 business days, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address Do you have a signed contract to reroof this property? It will need to be provided at the time of permit pick-up. 3090 Reed St, Dewight Trickler 303-234-0526 zielinski153@comcast.net Yes CI - NON CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Hometown Roofing and Exteriors 170247 303-980-6463 Contractor Email Address hometownroofing@comcast.net (permit pick-up instructions will be sent to this email) Retype Contractor Email hometownroofing@comcast.net Address DESCRIPTION OF WORK Is this application for a Yes new permit for a residential roof? Are you re -decking the Yes roof? Description of Roofing Gaf Timberline 30 year Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 18 material selected above? Does any portion of the No property include a flat roof? If yes, how many squares Field not completed. on the flat roof? TOTAL SQUARES of all 18 roofing material for this project 2 Provide additional detail House only here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 5300 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Anthony Collins Email not displaying correctly? View it in your browser. 3 FOR OFFICE USE ONLY Building er ` it Application Vaasa complete all highlightedareas on both sides this form. Incomplete applications may not be processed, Property Address: 300 V.,e-,-e( Address: City, State, Zip; Complete all information on BOTH sides of this foie S FULF Stu's Gallons Amps Squares Other DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owne~L/,/ L-'s fi'7 Property Address :ge5fd ~EE1'j ~T Contractor License No. : Company : Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANOING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibiliN for complia e with the Wheat Ridge Building Code (U.B.CJ and all other appli h t ftidge l nance , for work under this permit. (OWNER)(CONTRACTOR) S ✓ ~+~J D~ATE ~ / 2~ 'X Description BUILDING DEPARTMENT USE ONLY Approval : Zoning : e~irar~ares~„~ts~ Approval : Approval : Occupancy : Walls : Roof : Stories ction Value : % DnCr-O . Permit Fee : Plan Review Fee : Use Tax : Total : SIC : Sq. Ft. : Residentiai Units : Electrical License No : Plumbing License No : Mechanical License No : Company: Company: Company: Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: n f,PI3fi3m-wmt~ n giffRE&M~ m ff~iI'~tl~ (1) This pertnit was issueE in accortlance with the provisions set forlh in yopur application and is sut1'ect to the laws of the State of Colorado and to the Zoning Regulalions antl Building Code af Wheat Ritlge, Coloretlo or any other applica6le ordinances of the Ciry. (2) This pefmit shall expire if (A) the work authonzed is not wmmenced within sixty (60) days from issue date or (B) the building authonzed is suspended or abandoned for a penotl of 120 tlays. (3) If this permit ezpires, a new permR may be acquired for a tee of one-half the amount nortnally required, provided no Uanges have been or will be made in the original plans antl speuficalians and any suspension or aban0onment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, lull fees shall be paid for a new permit. 4) No work of any manner shall be done that will change the naNral Oow ol water wusing a tlrainage Droblem. 5) Contractor shall notify the Building Inspeclor iwenty-Pour (24) hours in advance for all inspections anA shall receive written approval on inspeclion wrd before proceetliing with successive phases ofthe ob. (e) The issuance o( a pertnit or lhe approval o~drawings and specifcations shall not De construed to be a permit tor, nor an approval of, any violation ot the provisions of the builtling cotles or any other ordinance, law, rule or regulation. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION Building Permit Number : Date : 1'fA-'(~ h~ - Phone~?~7- ~ . . . . . . DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 5771 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 9!3/97 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Properiy Owner : Property Address : 3090 REED ST Contractor License No. : 17152 Company : Precise Plumbing ONMER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby ceNry that the setbacAc distances proposad by this permk application are accurate, and do not violate applicable ordinances, rules or regulations of the Cky of Wheat Ridge or covenants, easements or res4rictlons of recoM; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by aii eond'Rions printed on this application, and that I assume full rosponsibility for comPliance with Ne Wheat Ridge Building Code (U.B.C.) aiM ail other appliceble Wheat Ridge ordinances, for work under this pertnft. (OWNER)(CONTRACTOR) SIGNED DATE Description : REPLACE WATER HEATER Phone : 237-8114 Phone : 534 0881 Construction Value : $349.00 Permft Fee : $22.00 Plan Review Fee : $0.00 Use Tax : $0.00 Total: $22.00 BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval : Zoning : Approval : Approval : Occupancy : Walis : Roof : Stories : Residendal Units : Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approval : Approval : Approval : ~ m . - ~ wfth (1) Regu~s e~MlBuiMlnign Co~de of~WlK Ri~e Cmvisions oloredo or arny Mhe~apPfpMa~ordinencea ofihe bjecl ~ e lawa of Hre State W Cobrado end ro the Zoniry tlp (2) This parmit shall expire If (A) the work euNOr(zetl is not commerwetl withm sucly (60) days trom lasue date or (8) the buildiiq aNhaized is wapentletl w abandone0 for a periotl ot 130 tlaya. (3) If thia permit expires, a ~row pertn~t mey be acquired Mr a fee of one-heN the amouM normaly required, provitletl no changea have been a will be metle in tlhe fe aiW any suspensbn w abantlonment has not exceetled one (7) yeer. It chenges are matle w if suspension or aberWOnment original plans antl specificatlons s aheN be paW tw a new permk. ex~etls one (t) year, fulle (4) No xrotk of any manner shell be done that will cherpe iha nelurel flow of water ceusinp a drainege problem. (5) Contracfar9 aN eo4'yag$ BulW~ng~lnspeclorb enry•four (24) houra in atlvar~ce tor all inspections arM shall receive wriUen approval on inspectlon card before o~oeeetl p f 1o (8) 71~e Issuence W a permR or Ne approval ot drewi~s and spedflcetions shall `wt be mnstruetl to be a pe~mit fw, mr an approval of, aity vidafbn of Me provisiona M the bulltling codes or any other ortlmarwe, law, rule or regulaUOa iief Building inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 . CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : Q T,,< k/-- Property Address : Phone~: z 3 -2~- Contrector License No. : r~- Company ~ 'S C~j. Phone : 3 3~ c~ y-y/ M. - OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING ANO AGREEMENT I hereby certiy that Ne seWatlc aistances proposetl Oy thls permrc appucation are accurate. and do not violate aooliCable orCmances. rules or teguunons of the City of Whea[ Ritlge or covenants. easemenn or rcstnctions of recortl: that all measurcments shown. an0 allegaUOnS -matle are accura[e: tnat I have read and agree ro aDWe by all eontlrtions pnntetl on lhis applieabon. ana mat I assume lull responsdllity kr compuana wim tne YMeat Ridge BuiWing Cotle (U.B.C.) and a11 oNer appueable Wheat R3jldge ominances. tor work u _bder tMS pertnrt. ✓j (OWNER)(CONTRACTOR) SIGNED O~= - DATE ~ Descnption Consuuction Value : j y y- Pertnit Fee : .22 - Use Tax : S<<-s Total : j 1 - BUILDING DEPARTMENT USE ONLY Approval : Zoning : "6lldfiist~CEftttf»-h~A Approval : P11bl~~WOr_kts'~1s_7i Approval : Occupancy : Walls Roof : Stories : Residen6al Units : Electncai License No : Plumbing License No : MeChanical License No : Company: Company: Company: Expiratlon Date : Expiratlon Date : Expirabon Date : Approval : Approval : Approval : ~ rPAps:RF9u(red` RIlfha ReZ~uirod:"ij rPjWMfflNuitfftl= (1) Thiz permn was inuea m acmroaruz wim the piovnwnc set IoM m yopur anpKaYOn and is w0qxt ro Ne laM pf Ihe SWS d Cobratlo and m IM Zamg Regulauons ana Bui10ing CoCe of NTeat RMq0. Co:aaao or arry olnar aDWKade oremanCes of Na Clty. (Z) This pertnrc snall exoirc rt (AI tne wonc aumonzeo a noi mmmenfza wioun vsty 160) CaYS hom issua Une a(B) the Wiltlup autlwnzae a susWntlstl or aWnEweo for a oenoo of 120 aays. (7) it mn cem+n exoiros, a new oemut may oe soquusa ror a fse ot one-nan tlne sumount nomuiy iaauirsA. prorwaC no tlhanpas nave Osen w wi4 W mwm n ma orgimi oians and apaafinoons am arry suspansqn w awnoonmem nas not eaoseaeo one It 1 yeu. 11 cftwqst in moa a rt wspanfqn or aeamnmem excxws one 11) reer. fun feea snsil x ww Mr a new oertnrc. (q No wonc of any manner anau x aone mat will cnange me natuoi now o/ watx vusnq a aninsge proDbm. (5) Cono-anor snan rwuN ine Bwimng insoeaw twenry-rour (24) noua m aovance ior an mspeeuons and anau reeava wntten approwi on mspecoon am eefon Oroceea^^9 wien successrve onases of tne pb. (6) T7ie usuanm of a cermn or me ao0mvai ot onwmqs ana seeaRpuons snau not De mnswc0 to De a pertM lor, npr an opprovai of. any hwoon of Me piwuwns of Ut! Dmlaing Copes or any otner oralnanl2. law. ru:e O/ re9ulaUOn. Buildmg Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION TN8 p'OAAit YA1:ICk ONLY WHEN 81f3!!ED BX 7HE CHIEE BUILDIM(3 INSPEC'i't)R ANQ MAYI'3R Cp1;,1.: `214-5833 24 HOURB-PRIOR TO INSPE+C770ii DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner:b w ic~' R~~r- ~Mc4ir'v- Property Address : 30° C) ~PeA ST Phone : 303- 2 3 7^g1<<( Contractor License No. :113 3 g Company : K.'~)eS'^ i OWNER/CONTRACTOR SIGNATURE OF Pnone (gpo)- 5'3 AND AGREEMENT I hereby certify that the selback distances praposed by this pertnR application are accurate, and do not violate applicable ordinances, rules or regulations of the Ciry of Wheat Ridge or covenants, easements or restrictions of record; thal all measurements shaxn, and allegations made are accurate; that I have read and agree to abide by all eonditions Drinted on this applicalion, and that I assume full responsibility tor compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable eat f2idge ordinances, for work under this pertnit. (OWNER)(CONTRACTOR) SIGNEDE,pL ~ DATE C -6)°v Description: I SO~F~,~~ Construction Value : °a Permit Fee : Use Tax : Totai : $0.00 Use: BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval: Zoning : gmI8~rt~3bhl81~rt1 Approval: emnMm Approval: Occupancy : Electricai License No : Company : Expiretion Date : Approval: Walls : Roof Plumbing License No : Company: Expiration Date : Approval: Mechanical License No : Company : Expiration Date : Approval: (7) This pertnil was iuued In acmNance wIN the piovisions set IoM In yapur aDWicafion antl is suCjec7 to Ure Wws of Ne Sta1e of CobraEO anO to the Zonirp RegulaGons aiM Buildirg Code of Nrtieat Ridye, CobraEO a any olher applica0le adinances of Ne Ciry. (2) T1iis pemut s1uU erzpire d(A) Ihe wak aWhanzeE bml commenceE wiNin suly (60) days Irom issue Oate a(8) Uw Wiltl4p auUaixed is auspended or abarWOneC la a period o( 720 aays. (J) U Nis pemvl eipires, a new pemut may be acqWred for a lee o/ one-haN Ne emounl rwrmaly reQuired, provi0e0 rw Wrges have Deen a wili be maEe in the original plans and speaficaUOns antl anry au5pef151011 W 3b3f1001VIMnl t13S nOl t%CCGOlO onB (7) yl2f. II Ch2f19G9 d!e 1NOC W if SUSPlnSiWl M BEdIMOnmOnt exceeds one (1) year, fuli (ees shall be paiE lor a new pemil. (4) No work of any manner shall De tlahe ihal will change Ihe nalural Ibw of waler wusirg a drainage poblem. (5) CanVactw slwll noGy ihe BuilGinq InspeUar lwenry-lour (24) hours In a0varice lor all inspeclions anE shail receive written approval on inspection pN Oelae procecdiirg witlM successive phaxe of ihe ob. (6) The issuanca o1 a pertnil or Ihe aDDroveI o C2win9s and spedliwGOns shall rwt Oe mns We0 to be a pemtit la, nor an approval ol, any vlolatlon of Ne provisions of Ne builEiny codes or any oNer adinance. Ww, rule a repuWUOn. Chief Building Inspector Stories : Residential Units : For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION