Loading...
HomeMy WebLinkAbout3335 Wright StreetCity of Wheat Ridge Residential Roofing PERMIT - 201801386 PERMIT NO: 201801386 ISSUED: 05/14/2018 JOB ADDRESS: 3335 Wright ST EXPIRES: 05/14/2019 JOB DESCRIPTION: Reroof remove and install Owens Corning Asphalt Shingles with 22 squares. Pitch 4/12. **REVISION: Adding redecking; Added valuation: $1,875.00 *** CONTACTS *** OWNER (720)289-8189 STEINKE THEODORE R SUB (303)552-4467 John Hess 150142 Urban Exteriors, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,529.00 FEES Total Valuation 0.00 Use Tax 158.11 Permit Fee 172.60 ** TOTAL ** 330.71 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201801386 PERMIT NO: 201801386 ISSUED: 05/14/2018 JOB ADDRESS: 3335 Wright ST EXPIRES: 05/14/2019 JOB DESCRIPTION: Reroof remove and install Owens Corning Asphalt Shingles with 22 squares. Pitch 4/12. **REVISION: Adding redeckingr Added valuation: $1,875.00 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the prope and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attestthat I legally authorized to i4c all entities named within this document as parties to the work to be performed and that �1I w'ork to b erformed is di =`n t ' tient and/or its' accompanying approved plans and specifications. Signatur 'OWNt or CONTRACTOR (Circle one) Date I.. Tliis permit was issued based on the information provided in the permit application and accompanying Flans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 da s made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3, If this permit expires, anew permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6 The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance oirygulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of Chief Ad"iiMing Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of WheatIkiclge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a-)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: '- Add to Permit # J Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: j _i Property Owner (please print): to P. r Phone:- �. v Property Owner Email: Mailing Address: (if different than property address) Address City, State, Zip: Submitting Company: UJ - o U FS Contact Person: JCAM e S S�� �It1 Phone: ;0-5 r( Contractor: Contractors City License #: l j� Phone: Contractor E-mail Address: SIL 2(9 ' i 6ci n .e &f cj—(& S I t c, Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour - 2 hour minimum). Description of revised/amended work: Sq. Ft./LF Amps Btu's Squares C, "t J- 7 Gallons Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) (AUTHORIZED REPRESENTATIV WNER) (CONTRACTOR) PRINT NAME: l �!') SIGNATURE: r ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS. Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received Water District ❑ Received Sanitation District ❑ Received L11 ENT USE ONLY DATE: -C- -if OCCUPANCY CLASSIFICATION: ❑ Not Required ❑ Not Required ❑ Not Required Building Division Valuation: $ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office,* (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L -1-m F P Job Address: -2,3 W r Permit Number: ❑ No one available for inspection: Time AM/I Re -Inspection required: Yes N When corrections have been made, call for re -inspection at 303-234- Date:- -'I— Inspector: ';k_1 DO NOT REMOVE THIS NOTICE I 7 v CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 C)G Job Address: X3335 W I< ! Crkl ST Permit Number: 20 i � O 13 8� ❑ No one available for inspectiefor ime 1.30 M PM Re -Inspection required: Yes When corrections have been made, ce-inspection at 303-234- Date:- S c�Ile- Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3OG Job Address: 33 5 Mel W-1 ST Permit Number: ZV 1 <9 O 13`3% IN ❑ No one available for inspection: Time f 0 �11 9/PM Re -Inspection required:�� No When corrections have been made, call for re -inspection at 303-234-5933 Date: r)d1r Inspector: DO NOT REMOVE THIS NOTICE 4 11 City of Wheat Ridge Residential Roofing PERMIT - 201801386 PERMIT NO: 201801386 ISSUED: 05/14/2018 JOB ADDRESS: 3335 Wright ST EXPIRES: 05/14/2019 JOB DESCRIPTION: Reroof remove and install Owens Corning Asphalt Shingles with 22 squares. Pitch 4/12. *** CONTACTS *** OWNER (720)289-8189 STEINKE THEODORE R SUB (303)552-4467 John Hess 150142 Urban Exteriors, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,654.00 FEES Total Valuation 0.00 Use Tax 118.73 Permit Fee 140.90 ** TOTAL ** 259.63 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge r Residential Roofing PERMIT - 201801386 PERMIT NO: 201801386 ISSUED: 05/14/2018 JOB ADDRESS: 3335 Wright ST EXPIRES: 05/14/2019 JOB DESCRIPTION: Reroof remove and install Owens Corning Asphalt Shingles with 22 squares. Pitch 4/12. 1, by m signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the roperty and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. I further attesfthat I am legally authorized to include all entities named within this document as parties to the work to be performed and that all w&k to be p formed is disclosed in this document and/or its' accompanying approved plans and specifications. t4 7 Signatureof "ER CONTRACTOR Circle one) Date I. This permi was issued bas` e%n-thepi-nfbfii ation provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3, If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granti f a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any s" appli.code or anyllainance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of ChieT Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. La enia Reimer From: no-reply@ci.wheatridge.co.us Sent: Monday, May 14, 2018 10:15 AM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in - the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name 3335 Wright St Tor Steinke Property Owner Phone 720-289-8189 Number (enter WITH dashes, eg 303-123-4567) i li c7���. f Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract Field not completed. Yes Steinke Rental Contract.pdf CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) Urban Exteriors, Ilc 150142 303-552-4467 3440 Youngfield St #179 Wheat Ridge CO 80033 Contractor Email Address jennifer@urbanexteriorsllc.com Retype Contractor Email jennifer@urbanexteriorsllc.com Address DESCRIPTION OF WORK TOTAL SQUARES or . 22 the entire scope of wo Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or 5500 S \'- v OTJ- W Pitched roof (2:12 pitch or greater) 2 both? (check all that apply) ��� What is the specific pitch 4:12 of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: 22 `_wens Corning Asphalt Shingl Type of material for thef Asphalt PITCHED roof: Provide any additional house detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant John Hess Email not displaying correctly? View it in your browser. Permit#:201401209 Issued: 12/11/2015 Stipulations: Install 1 egress window and well. This certificate verifies that the building constructed and/or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code and development standards of the zone district in which it is located and may be occupied. All other licensing requirements for the City must be met. M 1 92MM Owner: STEINKE THEODORE RI 3333 WRIGHT ST WHEAT RIDGE CO 800 Contractor* Theo G. Stephens PO BOX 1511 ENGLEWOOD CO 80115 NO change shall be made in the USE of NEC this building without prior notice NEC and a new Certificate Of Completion NEC from the City of Wheat Ridge. MMMMI� fflo�! Complete all information on BOTH sides of this form Sq. FULF Btu's Gallons Amapa Squares- Other WINDOW WELL DETAIL CASEMENT WINDOW FULLY OPEN lim Is 26' X 44' OPENING UK LUUIVALLNI WMtfq NLLLZ�,,�AKT USE MULTIPLE SETS OF 4' LONG STEEL SHIMS TOTALING 12' IN WIDTH BETWEEN FRAME AND I uu; I ORIGINAL WINDOW FRAME OR FRAME AND CONCRETE, TO FORCE BOTTOM OF NEW FRAME AGAINST BOTTOM OF CONCRETE CUTOUT, OR BETWEEN BOTTOM ORIGINAL WINDOW\ OF FRAME AND CONCRETE, -\ a FRAME FACE VIEW OF FRAME KEEP TOP AND SIDES OF ORIGINAL WINDOW FRAME IN PLACE, DO NOT CHANGE OR REMOVE ANY FOUNDATION WALL OR STRUCTURAL FRAMING ABOVE WINDOW 1 35 sec. GUSTS 4. ROOF SNOW LOAD 30 (lo./sq F BASEMENT EGRESS WINDOW DETAILS 5. GROUND SNOW LOAD 42.9 tb./ q Ft r- zrTzmir rip"lli Y /11 3335 WRIGHT STREET c WHEATRIDGE, CO 80033 SIZE TOR STEINKE 0wG NO W REV A D Sc ALE Ile 7DATE 25 JULY 2014 SHEET I OF I lifililimmmil I 97Y.T.T.Mr. SS) -- ----- ---------------- M ont G'T 0 mm� ' �bUg"N"LlIIJI't El RUILDING DEPARTMENT COMMENTS* Reviewer FIR9 DEPARTMENt: 0 approved w/ comments 0 disapproved 0 no review required laffillstr.16frMa , A. - ---------------- ............... Inspector Mu Sign ALL Spaces pertinent to this project F oundation Inspections Date I Inspector I Comments . a. r tt. ., ithir 4fat) ��ei fC.rr;Fa ent �. F o) e'e Enc ased Ground (C raj �..... _ F'oc,. PE Letter tic of Pour Concrete Prior To to — Incal (Underground s e v esr Ser vice {Und rcti t alonq (Elf-low l fstw 9 fk D o Not Cover Ut V'40 S!iewhing „ $"le tS {sr:� "�t9..$ze�ri0t;r3� t a3$$ � , t. vv / da$O Final Inspections Roof oo , Date Ins pec t o r InitiAs I • :. • w N • ♦ i#k •. �! ... ♦ ♦ is 11 ♦.: Ins pector .; n ALL Spaces p ertinent Foun dation . + Comments r Inspecti Final i roval Of Above F CITY OF WHEAT MIDGE a /13/ 13 3.-23 FIX edbb Timothy Bartels RECUPT RG. ARGU Inspector DPW Reolace fureace and 193.60 Initials 28138 #626 Permit iW e Use "pax 93.68 PAYMENT` RECEIVED ARGU VrG 7281 19160 Au th Code � 02587 TOTAL 193� 6 - r— F--fa. I ca 2 201 a-OS- 13 20[ 51 42 (<3 M'T') PI.— PI.90.ff. 11 T111 AIA oe P PhRna- Property Owner (please pfint).—�e`�"� Mailing Address (if difteren than property address) Addrefs, Zkovy =- - W 0 wo�jzmj Sub Contractors: c2milavy, "Am-c., W'S21 mck Exo1ration Date: JRd!ffPMf_e_jjjo_n: A Ak v_0- ♦ i CITY OF WHEAT RIDGE Building Inspection Division t (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Pr, Job Address: ;735 0 1',' Id 9, Permit Number: ' ~ xq J €ifC ❑ No one available for inspection: Time /I-fi/-2 "M Re-Inspection required: Yes 0 ' When corrections have been made, call for re-inspection at 303-2345933 Date: /U a,r Inspector: r, .,,e k r m o DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division r (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: lnlg:>gew Job Address: 3355 ~u~ grr s7- Permit Number: ogY~9,g5 APPOiIE Tc %1cSY/> T1T rTssln//!~ f/ i✓Jr~ Td ❑ No one available for inspection: Time a? 3S AM/PM Re-Inspection required: Yes No "When corrections have been made, call for re-inspection at 303-234-5933 Date: iv~G/©g Inspector:_~ DO NOT REMOVE THIS NOTICE " City of !Wheat Ridge 7 PERMIT NO: .:.0929' JOB ADDRESS: 3335 DESCRIPTION: Rero( ,ISSUED:' 10/05/2009 RIGHT ST.: "EXPIRES: 04/03/2010 24 sqs f CONTACTS owner 303/423-1918 Mykolo Myckansck sub 303/521-4192 Rudy Archibeque 0 PARCEL :INFO ZONE :CODE: UA ;.USE: SUBDIVISION:' 0695: :.BLOC 270,403 Archibeque. Roofing Inc. UA C/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION.: .:6,000.00 FEES Permit Fee 162.90 Total Valuation ` 00 ( Use Tax 108.00 1+OC a TOTAL 270.90 Conditions: 6 nail installation & mid roof inspection required. Board sheathing spaced more thana 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield required from'eave edge to 2'inside 'exterior walls. Subject to field inspection. ordinances, rules or regulations of the City of :Wheat Ridge or covenants, easements or restrictions of record, that all measurements shown, and allegations made are accurate; that I have read and agree to abide, by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code(I.B.C) and all other 4 applicapal? Wheat Ri a Ordinances, for work under this permit. Plans subject to field inspection. S nature contractor/owt r d to date This permit was issued in accordance with the. provisions set forth in your application and is subject to the laws of the. State of Colorado and to the Zoning.. Regulations and Building Codes of Wheat Ridge, Colorado or any lother applicable ordinances of the City. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension mayy be granted at the discretion of the Building Official. If this permit expires, a new permit may be acquired for -a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes.: have been or if suspension or abandonment exceeds one. (1) year, full fees shall be paid for a.'new permit:: No work of any manner shall be done that will :change the natural flow of water causing a: drainage problem. 6. The issuance of a permit or the approval of drawings and. specifications shall not be construed to be a permit for, nor an approval of any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. AlY-p1 r ew is subject to field inspections. Signs e Chief Buildin Official -date INS CC TION REQUEST LINE: (303)234-59.33 BUILDING. OFFICE: (303)235-2855 REQUESTS MUST.: BE MADE BY 3PM'ANY BUSINESS 'DAY FOR INSPECTION THE PFOLLOWING BUSINESS DAY. ~,oF yJHEgT~o City of Wheat Ridge Building Division m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 °o~oaPO° Inspection Line: 303-234-5933 Building Permit Application Property Address". 3 5-5- W P, t-~5 L Property Owner (please print): ll k0 /Y6~ v cr ,~I -<,1f pli Mailing Address: (if different than property address) Address: 11Y Zip: Contractor: O Contractor License Phone: 310)- SD " C,q 2~ Sub Contractors.: Electrical City License Company: Plumbing City License Company Mechanical City License Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction Value: $ 6L.)z) Description of Work- r (as calculated per the Building Valuation Data sheet) / -lz o o d//-f CD Ar C- O /L,) Plan Review (due at time of submittal): $ b Yx- 0=' h. e J ,1') / -'L1/ Sq. Ft./L.Ftadded: Squares,. BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT - 1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) ONTRACTOR) PERSONAL REPRES TATIVE of (OWNER) (CONTRATOR) PRINT NAME: 2G i OAf, SIGNATURE: Date: d u~ Z4 5i4 Date: Plan Permit - ' DEP RTMENT OF PLANNING AND DEVELOPMENT UILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE HEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number : 12097 Date : 5/7/2001 ~ 4 ~ Property Owner : ['Crk H7k__ Property Address : 333583tAj1 ST Phone : 238-2617 ntrector License No. : 19034 Company : APH Service Co., Ina Phone : 2956622 OWNER/CO TRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $2,600.00 I hereby certi that the setback distances proposed by this permit application are accurate, P@rmit Fee : $83.25 and do not vio ate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, ea ements or restrictions of recortl; that all measurements shown, and allegations Plan Review Fee : $0.00 made are acc rate; that I have read and agree to abide by all conditions printed on this application, a d that 1 assume tull responsibility for compliance with the Wheat Ridge Building Use TaX : $39.00 Code (U.B.C.), and all other applicable ea~ ordinances, fo wor p under this permit. (OWNER)(CO NTRACTOR)SIGNED 21 DATETOf21: $12225 Use: Descripti6 n : 200 AMP OH SERVICE CHANGE rco BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Zoning : Occupancy : Walls Electrical L6cense No : 19034 Company :iAPH Service Co., Inc. Expiration Date : 2/22/2002 Approval : ' OK/KS Roof Plumbing License No : Company : Expiration Date : Approval : Mechanical License No : Company: Expiration Date : Approval : (1) This pErmit was issued in accordance with the provisions set forth in yopur application and is sub1ect to [he laws of the State of Cobrado and to ihe Zoning RegN tions and Building Code o! Wheat Ridge, Colorado or any other applicable ordinances of the Ciry. (2) This ptrmit shall expire if (A) the work authorized is not commenced within siuty (60) days M1om issue date or (B) the building authorized is suspended or abantlpnea For a periotl of 120 days. (3) If ihis pertnit expires, a new pertnR may be acquired (or a fee of one-half the amount normally required, provided no changes have been orwill be made in the originAl plans and specifications antl any suspension or abandonment has not exceetled one (1) yeac If changes are made or if suspension or abandonment exceeQs one (1) year, full fees shall 6e paitl for a new pertnit. (4) No wo~k of any manner shall be done that will change the natural tlow otwafer causing a d2inage problem. (5) Contrd~or shall notiry ihe Building Inspector hvenry-four (24) hours in advance for all inspections antl shall receive written approval on inspection card before prorld h successive phases of the job. (6) Th f aIy~~rthe approval of drawings and specifwtions shall not be consirued to be a permit for, nor an approval of, any violation of the provisions ot y othe r ordinance, law, rule or re9ulation. t' Chief Building lApector Stories : Residential Units : DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 Date : CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 APPLICATIo N I. ~~kf ~~l^ Property Owner : 2 F~ ~ a` ~`7 ~ 3 ~ / Ph . J W Property Address ✓ : J one : -I ~~3LI Contractor License No. : 1 Phone : Company : J~ PN SiC,fU) ( Q~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or Pe~mli Feg : covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this liance with the Wheat Ridge Building m l t f Use Tax : p or o i y application, and that I assume full responsubi C.) and all other applicable ea ordinances, forwor underthis pertnit. B Code (U TOf21 : . . (OWNER)(CONTRACTOR) SIGNED DATE~ US2 : ~ ~L V_ Description : BUILDING DEPARTMENT USE ONLY 0 inTCo"'inlm-`€~~ts Zo- Q Approval: Zoning : Buitding; ommen sw Approval: Putilic'WOFk~'Gor irtTen~ts~ Approval: Occupancy: Electrical License No Company : APa Expiration Date : Approval : Expiration Date : Approval: Mechanical License No : Company: Expiration Date : Approval: (1) This pertnit was issue0 in accor0ance with the Orovisions set lorth in yopur ap0lication antl is subject to the laws of the State of Colorado and lo the Zoning Regulahons anC BuilOing Cotle o( Wheat Ritlqe, Colorado or any olher applitable ordinances of the Ciry. (2) This pertnit shall expire if (A) the work aulhonzetl is nol commented wilhin siaty (60) days from issue date or (B) the buil0ing authonzeE Is suspended or abandoned (or a penod of 720 days. cha been (3) long nal p ans and specficat on an0 any s spens on or abanaonment has not ezceeded one (tj yea ~roha ges are made o~'1 suspe sionloabanaonment exceeds one (1) year, lull lees shall be paid lor a new permil. (a) No work of any manner shall 6e done lhat will change the naWral flow of water causing a drainage problem. (5) Contractor 5hall notify the Builaing Inspector hvenry-Pour (24) hours in a0vance for all mspettions and shall receive wntten approval on inspection card Debre ceetliing with successive phases ot NeJob. (6) proot the Ould na owdes o iany othePominal ~ ea aw~nrale ordregulation,ions shall not De consWeO to be a pertnit /or, nor an approval of, any violation ol the provisions Walis : Roof 0 ~'J Plumbing License No : JIr~ I c.C~ Company : SIC : Sq. Ft. : Stories : Residential Units : Chief Building Inspector 73~2 7500 WEST 29th AVENUE 237-6944 EXT. 255 P.O. BOX 638 DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING INSPECTION DIVISION CITY OF WHEAT RIDGE, COLO. PERMIT N0. M911116990 ONLY WHEN SIGNED BY THE CNIEF BUILDING JOB ADDRESS CONTRACTOR ADDRESS ~ CITY 7 PHONE~.G SIGNS ~11r`f V~"1`JLY ZIPCODE! -1166 LICENSE NO. AND RECEIPTED BEL7w. OWNER PHONE ZIP CODE u~ :ONTRACT PRICE $ I, TYPE Ground❑ Wall❑ ProjeclinQ❑ 01hsr SaDFec* 2. MATERIAL Total Squon FNt 3. ILLUMINATION Yss❑ No❑ TyGe Eleet. Pa.mif No. _ ApprovW,Zona Incp~cta Zon* 4. SET BACK FROM PROPERTY LINE N_ 5_._ E Q`N a pieapprwed fSn.eilv which is front) ❑ I, 7YPE Solido Moro Than 80% ODanO Lest Than 80% ~ MATERIAL fENCES 3. SET BACK FROM PROPERTY LINE N- S-- (Soeaitv whieh it troM) ❑ ~/'1 G Ln U OTHER L e c, - 3. Hdpht yy Zuns_ ApprwW,Zorn Impseta n pisapproved DRAW SKETCH OR SHOW BEIOW, THE FENCE,SIGN,OR OTHER STRUCTURE,GIVING DISTANCES FROM PROPERTV LINES. (SETBACNS OR PROJECTIONS INCLUDED) ~ SPECIFV NORTH STREET NAME SIIOW OISTANCES FROM THE MAIN BUILDING TQADJOINING MOUSES,STREETS,AND PROPERTY LINES;ON IRREGUI.AR LATS, SHOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT PERFORM DATION UPON VAL THE THE THIS APPLICATION P ILA IT E`C~OMEE%PIREM60 DAYS FROM DATE OFaSSUANCE~M~OR1fYI5 PbT 5 AIR D WT H TMp7l TIANE INSPECTION DIVISION. PLUMBIN6 PERMIT MECHANICAL PERMIT ELECTRICAL PERMiT STATE LICENSE N0, STATE LICENSE N0. F1.00R BSM IST 2N0 3R0 4TH NQ FUEI'CrcclsO~~+~ta~~» EIscS ALUMINUM WIRE UNDER SIZE 8 ILLEGAL yyATER CIASET FORCED AIR - BTU HOT WATER - BTU TEMPORARY METER WASH BOWL STEAM - BTU NEW SERVICE AMPS BATH TUB AIR CONDITIONING-BTU ~.,..~r_c ccwvir.F-AMPS SMOWER nruca - WIRING MOTORS 8 INSPECTION RECORD Occupancy/Type INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. F!), 1 0 O W F F IT TV M 21q 1 _5 Lath / Wall tie .. IN PECTOR MUST SIGN ALL SPACES PERTAINING TO THIS J6B FOUNDATION INSPECTIONS DATE INSPECTOR. INITIALS COMMENTS: Footings /Caissons Electrical Service Stemwall / (CEG) Concrete Encased Ground Rough Electric ' Building Final Reinforcing or Monolithic Rough Plumbing Fire Department Weatherproof/ French Drain Gas Piping R.O.W & Drainage Sewer Service Lines Rough Mechanical INSPECTIONS FOR PLANNING S, ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL .INSPECTIONS. Parking & Landscaping Water Service Lines "'NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION QEA-CE nFtwE OF Occup- A NDY— NDRf -ERMIsSlONF_oR- occup -ANc POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR - Electrical (Underground) Plumbing (Underground) Heating (Underground) DO NOT POIIR FI OOR IINTII ARnVF HAA RFFN SV]NFII ROUGHS Sheathing Lath / Wall tie .. Mid -Roof Electrical Service Rough Electric ' Building Final Rough Plumbing Fire Department Gas Piping R.O.W & Drainage Rough Mechanical INSPECTIONS FOR PLANNING S, ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL .INSPECTIONS. Parking & Landscaping ADUVE INJPEU I IDNS IU tlE SIGNED PRIOR TO PROCEEDING Framing Insulation Drywall Screw FkNALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING S, ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL .INSPECTIONS. Parking & Landscaping "'NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION QEA-CE nFtwE OF Occup- A NDY— NDRf -ERMIsSlONF_oR- occup -ANc OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER