HomeMy WebLinkAbout3611 Tabor CourtNOTES BASED ON 2018 I.R.C. GENERAL NOTES THE GENERAL STRUCTURAL DESIGN HAS BEEN CONDUCTED IN CONFORMANCE WITH THE INTERNATIONAL RESIDENTIAL CODE (I.R.C.) 2018 EDITION AND THE CITY OF WHEAT RIDGE BUILDING CODE AMENDMENTS. DESIGN LOADS AS PER CHAPTER 6, 2018 I.R.C. WITH LOCAL AMENDMENTS: SNOW 30 PSF GROUND SNOW LOAD (NON-REDUCIBLE) WALL: 10 PSF DEAD FLOOR: 50 PSF LIVE - RESIDENTIAL SCALE: 10 PSF DEAD - RESIDENTIAL WIND: 135 mph (V ult) EXPOSURE'C' FROST DEPTH = 36" SEISMIC: SDC = B SOILS: MINIMUM BEARING PRESSURE = 1500 psf THESE DRAWINGS ARE "BUILDERS PLANS" INDICATING GENERAL DESIGN INTENT ONLY. IT IS THE BUILDER'S RESPONSIBILITY TO PROVIDE ANYADDITIONAL CONSTRUCTION DETAILS REQUIRED AND TO DICTATE METHODS OF CONSTRUCTION. THE BUILDER SHALL VERIFYALL DIMENSIONS OF MANUFACTURED COMPONENTS AND RELATIONSHIPS BETWEEN MATERIALS OR COMPONENTS. THE BUILDER SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS INCLUDING ALL EXISTING GRADES AT THE SITE. IF A DISCREPANCY ARISES BETWEEN THE DRAWINGS AND FIELD CONDITIONS, OR WHERE A DETAIL IS DOUBTFUL OF INTERPRETATION, OR AN UNANTICIPATED FIELD CONDITION ARE ENCOUNTERED, THE DESIGNER SHALL BE CALLED RIGHT AWAY FOR CORRECT PROCEDURE TO BE FOLLOWED. SUCH INSTRUCTIONS SHALL BE CONFIRMED IN WRITING AND DISTRIBUTED TO ALL AFFECTED PARTIES. WHERE EVER THERE IS A CONFLICT BETWEEN DETAILS AND SPECIFICATIONS, OR BETWEEN DETAILS, OR WHERE DOUBTFUL OF INTERPRETATION, THE MOST RESTRICTIVE SHALL GOVERN AS DETERMINED BY THE ENGINEER OF RECORD. THE BUILDER/CONTRACTOR AND ALL SUBCONTRACTORS SHALL CONFORM TO ALL APPLICABLE BUILDING CODES. SPECIAL INSPECTIONS: NONE REQUIRED REM DATE I REVISIONS I BY: /0\ 109/10/21 1 ISSUED FOR CONSTRUCTION I ACA I P���f psso Urai\e %`9.r i /fig ok \N heat j �� �►,, CD ng D� -LOCATION OF EGRESS WINDOWS RE: S1.0 PROJECT NAME: ,Ashworth Structural, Inc. Structural Design and Analysis Basement Remodel Egress 15572 South Elk Creek Road. Pine CO 80470 7 PHONE: 720.988.3868 ashwcrthaashwarthstructuralcom 3611 Tabor Court THIS DRAWING IS CONSIDEL'ED A PROPETARY PROOUCT Of ASHWORTH STAUCTURAL INC. IT IS NOT TORE USED OR REPRODUCED IN ANYMMNER UHLIMS AUTHORIZED IHWRTnNG Wheat Ridge, Colorado 80033 BY AS MOWN STRUCTURAL. INC FRAMING NOTES ALL LUMBER SHALL BE SOUTHERN PINE GRADE NO. 1 OR BETTER, WITH A BASE MINIMUM ALLOWABLE EXTREME FIBER BENDING STRESS FOR MEMBERS (Fb) OF 1050 PSI EXCLUDING ADJUSTMENT FACTORS FOR USE, SIZE, LOAD, DURATION, ENVIRONMENT, ETC., UNLESS OTHERWISE NOTED. STUDS SHALL BE STANDARD GRADE OR BETTER. ALL LUMBER IN CONTACT WITH CONCRETE SHALL BE ACQ TREATED TO 0.40 PCF. FRAMER RESPONSIBLE FOR REQUIRED PLUMBING AND HEATING, RUNS AND CHASES. REQUIRED MINIMUM NAILING SCHEDULE: (SEE IBC TABLE N0. 2304.10.1) (8D COMMON - 2.5" X 0.131", 16D COMMON - 3.5" X 0.162") STUD TO PLATES TOENAIL 4-8D COMMON OR END NAIL 2-16d. ROOF BLOCKING TOENAIL 3-8d COMMON. DOUBLE TOP PLATES FACE NAIL 1-16d STAGGERED 16" OC. DOUBLE TOP PLATES LAP SPLICE FACE NAIL 2-16d COMMON. DOUBLE STUDS FACE NAIL 1-16d 24" OC. CORNER STUDS AND ANGLES 1-16d COMMON 24" OC. RIM JOIST TO SILL TOENAIL 1-16d 6" OC. JOIST TO SILL OR GIRDERS TOENAIL 3-8d COMMON. DOUBLE SOLE PLATES TOGETHER FACE NAIL 1-16d STAGGERED 8" OC. BRIDGING TO JOIST TOENAIL 2-8d COMMON AT EACH END SHEATHING TO RAFTERS/TRUSSES FACE NAIL 8d 12" OC FIELD, 6" OC EDGE SHEATHING 48" AT ROOF EDGES FACE NAIL 8d 4" OC SHEATHING TO STUDS FACE NAIL 8d 12" OC FIELD, 6" OC EDGE ALTERNATIVE: ATTACH SHEATHING WITH 8d NAILS, 1-1/2"X15 GAUGE STAPLES, OR 1-3/4"X16 GAUGE STAPLES AT 6" OC AT PANEL EDGES AND 12" ON CENTER FIELD SPACING. PROVIDE BLOCKING AT HORIZONTAL JOINTS. NAILS OR OTHER APPOVED SHEATHING CONNECTORS SHALL BE DRIVEN FLUSH BUT SHALL NOT BREAK THE SURFACE OF THE SHEATHING. LVL BEAMS SHALL BE MICRO -LAMS AS MANUFACTURED BY TRUSS JOIST CORP OR EQUAL WITH Fb 2600 PSI, Fv 285 PSI, E 1900 KSI TO BE INSTALLED PER MANUFACTURER'S REQUIREMENTS. ALL INTERIOR GLUED LAMINATED (GLULAM) BEAM SECTIONS SHALL BE DOUG-FIR/LARCH OR EQUAL (24F -V8), ARCHITECTURAL GRADE, WITH Fb 2400 PSI, Fv 240 PSI, AND E 1800 KSI ALL EXTERIOR GLUED LAMINATED (GLULAM) BEAM SECTIONS SHALL BE PORT ORFORD CEDAR 22F -V14 OR EQUAL, WITH Fb 2200 PSI, Fv 265 PSI, AND E 1700 KSI. ALL MULTI -PLY BEAMS SHALL BE GLUED, NAILED AND/OR BOLTED AS PER MANUFACTURER'S RECOMMENDATIONS OR AS NOTED ON PLANS. FOR 2 -PLY SAWN LUMBER, USE (2) ROWS OF 10D NAILS @ 16" OC. USE 16D NAILING BOTH SIDES FOR 3 OR 4 PLYS. ALL MULTI -SPAN BEAM SPLICES TO OCCUR OVER POSTS OR BEARING POINTS. DO NOT BREAK BEAM PLIES MID -SPAN. THE NUMBER OF JACK AND KING STUDS INSTALLED ON EACH SIDE OF A HEADER SHALL COMPLY WITH TABLE R602.7. KING, JACK, AND CRIPPLE STUDS SHALL BE OF THE SAME DIMENSION AND THICKNESS AS THE ADJACENT WALLS STUDS. HEADERS SHALL BE CONNECTED TO THE KING STUDS IN ACCORDANCE WITH TABLE R602.3. CARRY ALL POINT LOADS CONTINUOUS TO THICKENED SLAB, CONCRETE PAD, OR FOOTING FOUNDATION DESIGNED TO CARRY LOADS. PROVIDE "SOLID STUDS" OR 2 MINIMUM GANGED STUDS IN WALLS AT BEAM BEARINGS AS SHOWN, CONTINUOUS THROUGH SOLID BLOCKING IN FLOORS. - tot, . •. re fir. _ ,17 Digitally signed by 3 ArthArthur Ashworth, P.E. Ashworth, P. E. Date: 2021.09 10 11:38:17 -06'00' SHEET NAME; GENERAL NOTES DATE: 09/10/21 DRAWN BY: ACA CHECKED: ACA SCALE: NTS PROJECT NO. 12.1-2.55 SHEET: G'1.0 ] ' City of WheatF 6 COMMUNITY DEVELOPMENT "REVIEWED FOR CODE COMPLIANCE" These drawings were reviewed under the applical laws in effect at the time of submittal. Reasonabl( effort was exercised in checking for code complia The stamping of these documents shall not be construed to be a permit for, or an approval of ar violation of state and/or local codes, ordinances c amendments thereto. Plan Reviewer DHartley Date 09/27/2021 EXISTING FRAMING- ABOVE RAMINGABOVE TO REMAIN EXISTING STEEL ANGLE LINTEL TO REMAIN CORRUGATED WINDOW WELL UNIT 12" MINIMUM FREE DRAINING GRAVEL SLOPE 1:12 AND COMPACT EXISTING SUB SOILS 3'-0" CONCRETE R.O. /11 /l11 i A TTT TT 11i A T T- x 7" SIMPSON VV E DGE-ALL ANCHOR AT 16" ON CENTER TYP 2 SECTION THROUGH WINDOW JAMB S s1.o +/- 8" CONCRETE FOUNDATION WALL pbbott-4s..S6 Olt /ng D`Jx •O \Nheat . C`01`�cv fng 5\'4"0 O .XISTING FLOOR FRAMING PROVIDE ESCAPE AND RESCUE OPENING: 1) Minimum net clear opening area: 5.7 sq. ft. or 5.0 sq. ft. at grade floor or below grade 2) Minimum net clear opening height: 24" 3) Minimum net clear openin width: 20" 4) Maximum sill height: 44" �2) 2x4 HEADER 09/10/21 BEAR ON JAMB STUDS O -� �O ACA CHECKED: ACA Z 2"O x 5" SIMPSON WEDGE -ALL ANCHOR ° AT 24" ON CENTER TYP. 2x6 P/T FASTEN TO o • e FOUNDATION w/ _ 2x6 SILL PLATE ed ° 09/10/21 X ACA CHECKED: ACA :. a• 2"O x 5" SIMPSON WEDGE -ALL ANCHOR ° AT 24" ON CENTER TYP. • e O ed a :a a d d. ° 4 INTERIOR CONCRETE SLAB ON GRADE 'A Is Is •� refir.-;;� W i EGRESS WINDOW ELEVATION 51.0 SHEET NAME; EGRESS WINDOW SECT. PROJECT NAME: 'Ashworth Structural, Inc. Structural Design and Analysis Basement Remodel Egress 15572 South Elk Creek Road. Pine CO 80470 7 PHONE: 720.988.3888 ashworthaashwarthstructurakcom 3611 Tabor Court THIS DRAWING 15 CONSIDERED A PROPETARY PRODUCT Of ASHWORTH STRUCTURAL INC. IT IS NOT TO BE USED OR REPRODUCED IN ANY MANNER UNLESS AUTHORIZED IN WRITING Wheat Ridge, Colorado 80033 BY ASWORTH STRUCTURAL.. ]NO. DATE: 09/10/21 DRAWN BY: ACA CHECKED: ACA SCALE: 1/2" = F-0" PROJECT NO. 12.1-2.55 SHEET: S1.0- s t CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office - (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time M1PM Re- Inspection required: Yes No * When corrections have been made, call for re- inspection at 303-234-5933 Date: i/ r% - Il > Inspector v DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax ❑ No one available for inspection: Time 1G� m�p R e- Inspection required: Yes No "When corrections have been made, call for re- inspection at 303 - 2345933 i r Date: 0 Inspector: DO NOT REMOVE THIS NOTICE INSPECTION NOTICE Inspection Type: �b N Job Address: Permit Number: /V/ RF ❑ No one available for inspection: Time 1G� m�p R e- Inspection required: Yes No "When corrections have been made, call for re- inspection at 303 - 2345933 i r Date: 0 Inspector: DO NOT REMOVE THIS NOTICE e `e CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: Job Address: .7411 7 4;Egg e 7r Permit Number: /496.5Gr5 ❑ No one available for inspection: Time ,'< 30 AM Re- Inspection required: Yes.. - * When corrections have been made, call fo --r re // - inspection at 303 - 234 -5933 Date: is Inspector: DO NOT REMOVE THIS NOTICE ~oF""E?TR City of Wheat Ridge Building Division Date: 7500 W. 29"' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Plan °oroRPO° Inspection Line: 303-234-5933 Permit#: Building Permit Application PropectyAddress 1/ / L 2 G74~ Property Owner (please print):~~~ Phone: Mailing Address: (if different than property address) Address: City, State, Zip: `w/ 4e. 2 c-7c? 00&2 Contractor: Contractor License !U z 2.3 G y Phone: -,2. P -"l > F Sub Contractors: Electrical City License Company: ,Exp. Date: Plumbing City License Company Exp. Date: Use of space (description): /~e - Descrip"tion of work: - Mechanical City License Company: Exp. Date: Construction Value: $ ~7Soy - (as calculated per the Building Valuation Data sheet) Plan Review (due at time of submittal): $ we cl Z4 Sq. Ft./L.Ft added: Squares 2G BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR) PRINT NAME: Sf4/L-JL" 6Ze~LG a~. c, SIGNATURE: "-_e.Date:-11.10 aired" I Bldg Valuation: $ DEPARTMENT OF PLANNING AND DEVELOPMENT ` BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number Date 9928 12/17/99 Property Owner : Property Address : 3611 TABOR CT Contractor License No. : 17152 Company : Precise Plumbing Phone : 423-2173 Phone: 534 0881 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurete, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and ayree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE Description : Replace water heater Construction Value : $365.00 Permit Fee : $23.50 Plan Review Fee : $0.00 Use Tax : $0.00 Total: $23.50 Use: BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval : Zoning : W Approval: ~ Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval: Plumbing License No : Company: Expiration Date : Approval : Mechanical License No : Company : Expiration Date : Approval: (1) This permit was issued in accortlance with the provisions set torth in yopur application and is subjecl to the laws of the State of Colorado antl to the Zoning Regulations and Building Code of Wheat Ridge, Coloredo or any other applicable ortlinances of the Ciry. (2) This permit shall expire it (A) the work authorized is not commenced within sixty (80) tlays from issue date or (B) the building authorized is suspended or abandoned for a period of 120 tlays. (3) If this permit expires, a new permit may be acquired For a fee of one-half the amount normally required, pmvitletl no changes have been or will be made in the original plans antl specifications antl any suspension or abantlonment has not exceeded one (1) year. If changes are made or it suspension or abandonment exceeds one (1) year, full fees shall be paitl for a new pertnit. (4) No work of any manner shall be done that will change the natural Oow of water causing a dreinage problem. (5) Contractor shall notiry the Building Inspector lwenry-four (24) hours in advance for all inspeclions and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) The issuance of a p,¢uqit or the approval of tlrawings antl specifiwtions shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the buildinQfAds3 ot any qther,p5dinance, law, mle or regulation. Chief Building OEPARTMENT OF PLANNING AND DEVELOPMENT Buiiding PeRnit Number : BUILDING INSPECTION DMSION - 235-2866 • . CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner ://7''° e7 m' n o s~ . . Property Address : 3 G f - Phone•: Convactor I.icense No. 7/ S-~2, r' 3 s j) CompanY: c- Phone:s'-?y-o8'$"/ ~ OWNER/CONTR4CTOR SIGNATURE OF UNOERSTANOING AND AGREEMENT I nsrsbr cortih tnac me xtbadc oisnnosr orooosea oy mis psrtna apoacation aro acauau. ara do not vbats aoohcaWe oromanass. nws or rspwanons ot tM City of WMn RidP a eownartts. eassmerns a rssbktions ot Wad: tlut an meatunmmn shown. and aM@O+bwns rrteft aro aoeuna: Mu 1 havr Alliao and ro abdt py aII mpipons OmIW an Mb appYpdon. ano mat I assunr hA 1or oenqiqnd wN tM YNrm RWp Butatry CoOe (U.B.C.) ana an oea aDPmabb Nhwt aonanas. br worlc uiWrtns Pe.. K. (ownEaxcorrra,ocroa) sicNen••-, oATE Construction Value : Pertnit Fee : a I SD UssTax:.;P-0^S rao~v!'S roto: 23 Description :jr-V/w ct 40'A' l.•,- ilYO 14,- , rr.ad rrov, i 4 5,&.e e,•e., BUILDING DEPARTMENT USE ONLY APProval : Zoning : Qel Ii1a~~ . APProvaL~ • ' APPreval: I Occupancy : Walls : Roof : Stories : Residen6al Units : I Electncal License No : Plumbing Ucense No : Mechanical License No : Company: Company:' Company; Expiration Date : Expiratlon Date : Expiradon Date : Approval : Approval : Approval : ~ cP,tllliis:Ri'9ufred= ~ : PflfhsReiquired:"'~ a ~u4~l~1 (i) Thli 0lRM wi3 63YlE m i00010il1G wR1 tlN 0ovisions 1M bNl lll y0p11I iOWma0011 !M 1i iWl~ q IM 4Wi N IM SIaY W COIOq00 NO ID IfM ZdWlO Rspuuua+s ana BuiWmq Coos ol WMec Rbqe. Ca:anoo w any opNr aopinOM orouunns M tna Cily. ; z) Tnis oarmn snan saove d (n) me wonc suvanzea u noe comm~neea wmmM +uM (EO) aav$ hom ww an a(e) tM owCUiO auuwn:w n w~orw~C a awroonea ror a osnoa or uo wya. (7) u wa Wninot *:evsa. a n" wrmn m+Y oe arnurw ar 3 rN W anHytl Or unotmn npnuW nauvW. pwiaa no dwq" ntw 6001111 orwY W nra n tlr pIW1U Wna an0 7D~OOIq N10 illy fYlOMtIM 0f aWf100MMIR IYS 1101 NIpWb OM (i) yaY• II f11Mvy wry Ilqa OI if WtpMUqll C! NI/IOwoMIR 01tC7W7 Of1011) yew. hIM fMi f1Y1 W 0m bf a IMM OMIR (4) No wMc d aM MarinK snan Oe Oone Out wll tlue" vN nblural Ilpw d "Nr ousmq a Oramaqe pro0lMn. 's) Conaaaor snan nouN i+e Bueauig inswttn nwnry•wur (74) noun m awana ror an mspacoona uq inan rw" wnpen gppevu an nypomon oio pMae prpGlymq wiN suftsfsne onafes a Ine p0. :6l iTe usuance ol a permn w tne s0aw+i W anwnqs alw seealnuons snau rwt Do mnstruaa b De a pemm Ax. npr gn apprwsi W. aM voaoan M IM Orowenf 0f CIe DuiICtn9 ooOGS Or iny ONN NG,OiI1C2. liW. N;! M RyWYM. Chief Budtling Inspector- For Mayor _ THIS PERMIT YALID ONLY WHEN SIGNED BY THE CHIEF BUILDINC+ INSPECTOR AND MAYOR CALL: 2345933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF GOMMUNITY DEVELOPMENT 7500 WEST 29tn AvENUE BUILDING INSPECTION DIVISION PERMIT N0. M911117237 237-6944 Ex7. 255 P.O. BOx 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALIO ONLY WHEN 516NED BY THE CHiEF BWLDING INSPECTOR AND RECEIPTED BELOW. JOB ADDRESS - ZH~nOK C CONTRACTOR /J'l U~ YJ /L~ , d~E'NN ADDRESS 7 74 / S. L oG,$rv QQ , CITY LiTTL.E'7'OW ZIPCODE0/22-2b',3U PHONE 79'R'R7~C-a LICENSENO. LLANEOUS PERMIT OWNER A~-AlN/S /XloN ADDRESS 16 ~~,&OR CT PHONE L Zq - O S ZIP CODE~003J CONTRACT PRICE $ Z-- ~ yrJ DATE ST~~ 2~ 9 L TYPE Ground ❑ Wall❑ Prolettlnp❑ 01Mr 5 a 0 Feee 2. MATERIAL Tofal Squon Fsef SIGNS 3 ILLUMINATION Yae❑ No❑ Typs Eleet. Psrmit No. 4. SET BACK FROM PROPERTV LME N_ 5- E_ W Zone_ Apprwed,ZOna tnapsda (Spxify whith ia front ) ❑ ❑ ❑ ❑ DisapDroved 1. TYPE Solid[3 More Thon BO% ODSnO Lest Thon 80% Open MATERIAL Hoipht FENCES 3. SET BACN FROM PROPERTY LINE N_ S_ E_ W ione_ Apprwed,iorn tmpeetor (Specify which ie front) ❑ ❑ ❑ ❑ Diaapproved i. OoF C'muc..iNF m-~t 6wa~ o-~ gstZ.L, e/... z. 3-74W F,vr ctm~,wa- OTHER DRAW SKETCH OR SHOW BELOW,THE FENCE,SIGN,OR OTHER STRUCTURE,GIVihG DISTANCES FRdAPROPERTV LINES. ($ET84CNS OR VROJECTqNS INCLUOED) INSPECTION TICKET ► JOB ADDRESS 3(f)( ` ~1~LJF't OTl ' RTH GI DATE: ~ a BLDG. PERMITN 11 C13J ...p PERMITM ` STREET N4ME c SHOW DISTANCES FROM THE MAIN BUILDING TPAOJOINING HOUSES, BLOG. CONTi~~ ~F ~ J('tk n D P C k` K) [ DISTANCE TO PROPERTY LINES,NOT MAXIMUM OR AVERAGE DIS APPLICATION FOR PLUMBING; ELE SueCON7RACTOR THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICA Q~ PERMITWILLEXPIRE 780DAYS FROMTHEDATEOf DATE INSP. REQ._~, /ISION. ELECTRICAL PERMIT STATE LICENSE N0. PLUMBII TYPE OF INSP. L- STATE UCENSE N ALUMINUM WIRE UNDER SIZE 8 ILLEGAL FLOOR BSh INSPECTION MADE ~v E Sda NO. WATER CLOSET TEMPORARY METER WASH BOWL REMARKS NEW SERVICE - AMPS BATH TUB CHANGE SERVICE-AMPS SHOWER LIGHTING SINK HEATING GARBAGE DISV POWER SUB-CIFCUITS WATER HEQTER W.R. FORM 679 ✓ UTIIITY (RANGE, DISPoSER, ETC ) AUTO. WASHER FIXTURES DISH WASMER N WIRING MOTORS d CONTROLS FLOOR DRAIN SIGNS URINAL TRANSFORMERS d RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FI%TURES REMARKS 1 Mreby acknowledae ihat this apDlico- ti0n I6 COrrett ond undersfond Ihot I cannot ffart this project until this appli- cotion it aDOrOVed. I sholl comply witn ths lawa oi the State of Colmado and 10 , PERMIT FEE tM ZoninQ Requlolions and BuildinQ Code oithe City of Wheai Ridpe. Any violotion of the obove terme will couse immediole revocotion oi this permii use rax TOTAL FEE CHIEF BUILDI~r, INSPECTOR,City of Wheat Ridqe Date Issued NOT VALID UNLE55 RE EIF Ft /'~'w /2 CALL 237-8944 EXT. 255 24 HOURS IN ADVANCE FORINSPECTIONS