HomeMy WebLinkAbout3200 Routt Streeti CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: -105 -141,J. e-00 Job Address: -300 110U- f = Permit Number: 70400716 ❑ No one available for inspection: Time _ ws` 5— AM/PM Re -Inspection required: Yes M,IV91 When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: )d1f-6- Lave,V DO NOT REMOVE THIS NOTICE *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201800736 PERMIT NO: 201800736 ISSUED: 03/15/2018 JOB ADDRESS: 3200 Routt ST EXPIRES: 03/15/2019 JOB DESCRIPTION; Residential Reroofing Permit remove and replace Monier Shake Field Brown Concrete Tiles with 5squares. Pitch =4/12. Provide G TnG illation Specification Sheets. *** CONTACTS *** OWNER (303)233-9485 PETER FREDERICK KLAMMER & CYNT SUB (303)295-2220 Tomas Wofram 110052 Core Contractors, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,950.00 FEES Total Valuation 0.00 Use Tax 61.95 Permit Fee 93.35 ** TOTAL ** 155.30 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201800736 PERMIT NO: 201800736 ISSUED: 03/15/2018 JOB ADDRESS: 3200 Routt ST EXPIRES: 03/15/2019 JOB DESCRIPTION: Residential Reroofing Permit remove and replace Monier Shake Field Brown Concrete Tiles with 5squares. Pitch =4/12. Provide Manufacturer&#39;s Installation Specification Sheets. 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I , the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am leg�ally authorized to include all entities named within this document as parties to the work to be performed d that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is sub3ect to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2, This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Off tial and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or grantin of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any appli r"code or any finance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. enia Reimer From: no-reply@ci.wheat ridge.co.us Sent: Thursday, March 15, 2018 9:59 AM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION LZA mw�&��J-PeCo- p Y Pro ert Address 3200 Routt St 'r ` (J Property Owner Name Peter Klammer Property Owner Phone 303-233-9485 Number (enter WITH dashes, eg 303-123-4567) L Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Field not completed. Yes Attach Copy of Executed Klammer Contract.pdf Contract CONTRACTOR INFORMATION Contractor Business Core Contractors Name Contractor's License 110052 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-295-2220 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 4049 Saint Paul St (Primary address of your business) Contractor Email Address bburkholder@coredoes.com Retype Contractor Email Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work: Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or bburkholder@coredoes.com 5 Max (tile repair job) 885.00 �q6-6, (]0 No Pitched roof (2:12 pitch or greater) N both? (check all that apply) What is the specific pitch of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: Type of material for the PITCHED roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) 4/12 5 Monier Shake Field Brown Tile Tile/Clay/Concrete Tile Repair job, estimated to be about 45 tiles to replace. SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal 3 owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Brady Burkholder Email not displaying correctly? View it in your browser. 11 a • IM " is wan um s s I 19 S• ! ♦ p6tMit ' p, likshrill, i: I^`• *. a► a • r• ♦ r'st: :ss state, Zip: rl 01 r. rt a rs I P � ov t/yc Rw <V /r9 /; f or • • • reaso ' a , d> Wheat City of jjge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Date: IW/10 Plan# /et • &999/ Permit # Iq 7 s Building ( Pe er rmitA l pp o lication LV 'I ProperlyAddress> �Z �uc c�rGISZ (�Ca��c�r5326 Property Owner (please print) (t{9ryy 4t14LYVh Phone: 3d T 33 Mailing Address: (if different than property address) Address: 3wo City, State, Zip: (— q �q Contractors City License #: Phone: Syp rival: ctors i Electrical: Plumbing: Mechanical: City License # City License # City License # De'scr ptid of work - 5 (woo CilC � � �5 CL 5 c (^ l�)r $ ontract Value P,9 \ i �(Jl/J s (how v /h�is{jnr� �S�0ki(S`! SIcCIIN, q'Y.05 sat Review Fee (due at time of submittal): Squares BTU's Gallons Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also autho ' d by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: ) (CONTRACTOR) or (AUTHORIZEDREPRESEN T! ) ER) (CONTRACTOR) PRINTNAME: $ PG ` ` I1tCC SIGNATUR DATE;�� Bldg Valuation: $ 3 - 2 CO gc(�c+k S A — L E 9 3 S� � O C t�e a o N 00 L N N mm I t / a �,� (-J REVISIONS ZONE REV DESCRIPTION GATE APPROVED �S errace eve t f awn g e ;- T -race oLV' side`w l grade I above t n _ q ° 6p /" Black k a sl waC r d an of Prop b o u r) r Pro osed P cy Fe Cre ted 6 w nd A ° -- Sidewalk A 32nd Ave. )� u `1 q `u g `r TGVIC� a 'l✓^ (� ,(7T6 SIZE= N0. REV SCALE SNEEi mm I t / a �,� (-J Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Mid Stemwall / (CEG) Concrete Encased Ground ... - - Reinforcing or Monolithic - Weatherproof /French Drain Ro ug Sewer Service Lines - Gas Water Service Lines Rough Mechanical POUR NO I:ONCRETE UNTIL ABUVL MAS OttN S---t- F NCRETE SLAB FLOOR ctrical (Underground) Plumbing (Underground) - Heating (Underground) DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED ROUGHS Sh §Wa lltie Lat Mid ... Eleice .....` Rou - Building Final Ro ug Fire Department Gas R.O.W & Drainage Rough Mechanical Parking &_ Landscaping -. - ABOVE INSPECTIONS 1U Ut SIGNtu rnIUN w rrcUi.tc�uw Framing Insulation Drywall Screw FINALS Electrical Plumbing Mechanical -. ... Ro .....` Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking &_ Landscaping _ . "NOTE.' ALL I'I'EMS MUS7`BE COMPLETEDAND APPROVED AND. - CONING; taUJLDINt� ANU -rLCr l�.- wy-�+r �- �U�ra� -n- CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. - OCCUPANCY NOT PERMITTED'UN - m CERTIFICATE OF OCCUPANCY IS ISSUED a P ROTE CT THIS CQR FCtOM THE WEATH ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE' r Inspection Type: Job Address::-it I cif, Permit Number: E Cry(n f\ ❑ No one available for inspection: Time AM/Q Re-Inspection required: Yes t,No 1 t~✓~ When corrections have been made, call for re-inspection at ,103-234-5933 A Date: Inspector: ri.i , s n 1 DO NOT REMOVE THIS NOTICE STOP WORK ORDER You are hereby ordered to stop work located at: Date ! i t " 9 Building Inspector: r X N ♦ i CITY OF WHEAT RIDGE Building Inspection Division r (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: r LV~ 00 ~d Job Address: ROU41 Permit Number:C'7 ft( z:_ /r I Pro F i rf ❑ No one available for inspection: Time P`PO AM(!!~M) Re-Inspection required: Yes ' When corrections have been made, call for re-inspection at 303-234-5933 l ~ ~ i~ f1 Date: 10''2 / ,(41 Inspector: P4ioeh. r_r'r DO NOT REMOVE THIS NOTICE "4' City of Wheat Ridge r; Res. Miscellaneous PERMIT - 094477 " PERMIT NO: ?094477 - 'ISSUED:' 12%17/2009 lt; JOB ADDRESS: 3200 ROUTT ST :.EXPIRES: 06 /15/2010 y DESCRIPTION:; Replace 4 16' pieces of trim for rotted trim . ` CONTACTS owner 303/233-9485 Cindy Klammer sub 303/668-4650 DAVID NEB 07-0205 NORTHLAND CONSRUCTION PARCEL INFO ZONE CODE: UA :USE: UA SUBDIVISION: 0660 BLOCK/LOT# : 0/'. s FEE SUMMARY ESTIMATED PROJECT VALUATION: ' 100.00 FEES - Permit Fee P." Total Valuation .00 ,J r o p`°'~ ! e Use 'Sax i. 1.80 TOTAL 32.35 ""Conditions: Subject to field inspections. v I hereby certify; that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of :Wheat Ridge or covenants, easements or restrictions of record; that all measurem shown, and allegations made are accurate, that I have read and agree to abide by all conditions printed on this applic ion a d'that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other >2:' appl c le Wh at Ridge Ordinances, for work under this permit. Plans subject to field inspection. Big a caner date ~oF""Et?go City of Wheat Ridge Building Division m 7500 W. 29"' Ave., Wheat Ridge, CO 80033 _ Office: 303-235-2855 * Fax: 303-237-8929 (o---- o Inspection Line: 303-234-5933 OCORPO Building Permit Application Property Address: 32C b `Ro 4 S 1 Property Owner (please print): Mailing Address: (if different than properly address) Address: Date: Plan Permit ocl Phone: S o 3 2 3 3 948 T State, Zip: Contractor: _ N o r ~-K I e, co?,s~ . Contractor License Phone: 3 0 3 6 6 6 S C) Sub' Contractors: Electrical City License Company: Plumbing City License Company Mechanical City License Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction value: $ / oo Description of Work; / (as calculated per the Building Valuation Data sheet) DI q~ 1 e c C S C7 L Plan Review (due at time of submittal): $ x 4 -4 r ro^ -Ro r r 6ff l c~.~Prd ck,tick onPpe -trim. Sq. Ft./L.Ftadded: Squares BTU's Gallons Amps OWNER/CONTRACTORSlGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans ublect to field inspection. CIRLCE ONE: OWNER) II ONT CTOR) or PERSON PR TATIVE of (OWNER) (CONTRATOR) PRINT NAME: 41z SIGNATURE Date: 17 -d $ Bldg Valuation: City of `Wheat Ridge Residential Roofing PERMIT - 093586 PERMIT NO: 093586.;.. ISSUED: 10/22/2009 JOB ADDRESS.: 3200 ROUTT ST `.EXPIRES: 04/20/2010 DESCRIPTION: T/O: :Install 46 sqs of Monier tile. ***_CONTACTS owner 303/233-9485 Pete Klammer go 303/789-1505 Jennifer Petersen r 02-0371 Jenesis Roofing, LLC PARCEL. INFO ZONE 'CODE: UA USE: UA SUBDIVISION:. 0660 BLOCK/LOT#: 0/ **'FEE SUMMARY ESTIMATED PROJECT VALUATION: 25,300.00 FEES Permit Fee `521.83 Total Valuation ,00 Use Tax a 455.40 TOTAL t ~ }g .977.23 e';_ ~,°.~...,...:.~....~,.._',1. `Conditions: JS: *Complete and have inspected all structural work prior to installing new roofing tiles. 6 nail installation mid-roof inspection required. Board sheathing spaced more thana 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield required from eave edge to 2' inside exterior walls. ***Contractor/Property owner shall provideladder(s) secured in place for inpsections. Subject to field inspection.` I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate. applicable ordinances, rules or regulations of the City of :Wheat Ridge or covenants, easements or restrictions: of record, that all measurements shown, and allegations made are accurate; that I have read and agree to abide. by all conditions printed on this application and that I a ume full responsibility for compliance with the Wheat Ridge Building Code (i.B.C) and all other:.: applicable eat Ri ge r inances, for work under this permit. Plans.. subject to field inspection. Signature o c tractor/owner '..date 1. This permit was issued in accordance with the :provisions set forth in your application and is subject to the laws of the State of Colorado and to. the zoning Regulations and Building Codes of Wheat 'Ridge, Colorado or any other applicable ordinances of the city. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date An extension may be granted at the. discretion of the Building Official: 3. If this permit: expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or :abandonment has not exceeded one „(1) year. If changes.-have been.-or-if_.suspension or-abandonment-exceeds one-(1) year -full fees-shall be paid for a: new.. permit. 4 No work of any. manner shall be done that will change the natural flow of water causing adrainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and :shall receive written approval on inspection card before proceeding with successive phases: of the job.` 6. The issuance of a permit or t approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any of la o the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subj gpp field: inspections. Signature of Chief Build ng Official date NSPECTION, REQUEST LINE: (3.03)234-5933 BUILDING :OFFICE: : (303'):235-2855. '2 A~oF w"~?>9 City of Wheat Ridge Building Division '...°m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-235-2857 c-,..u o Inspection Line: 303-234-5933 Building Permit Application Date: Plan Permit M Property Address: 3200 ~O U 7Y- 5-)L- Property Owner (please print): ]me-4-e- K t Q m w y-or Phone: 3;9 3 -,2,3 3 Mailing Address: (if different than property address) Address: , j--ro sK 6 U'i-/ S4• City, State, Zip: i?0D.33 Contractor: : ~ ,A4P_~ 5 00{ w Pil Contractor License Phone: 30 3 -751/ 565 Sub Contractors: Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval Use of space (description): e i Construction value: $ 25 300, Do Description of work. (as per the Building Valuation Data sheet) ~✓L _s/ +Plan Review (due at time of submittal)`: Inoni ei-r.~l-o- Sq. Ft.(L.Ft added: Squares ~16 BTU's Gallons Amps OWNER(CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C). and all other applicable Wheat Ridge Ordinances, for work. under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTA VE of /OV ER) (CONTRATOR) PRINT NAME: -J-eNhi'tY~`Zf-f YID( SIGNATURE: iON' Date: /0-OZX- ZONING COMMENTS: Zoning: Reviewer. DEPARTMENT USE ONLY PUBLIC WORKS COMMENTS: Reviewer. - BUILDING DEPARTMENT COMMENTS: (iCl//+LGL- /9/47 - /~w " w ~ OCCUPANCY: Reviewer. - I STRUCTURAL ROOF FRAMING EVALUATION REPORT Job No. KLMl-09164 Date signed: October 1, 2 Cindy Klammer 3200 Routt Street Wheat Ridge, Colorado 80033 ~p00 REGST oo~~'BEN~~~F~a 3839b z° S ON AL Re: Structural feasibility of re-roofing your residence at 3200 Routt Street, Wheat Ridge Dear Mrs Vic- »W EI On September 10, 2009 David Benjamin of our office, and on September 29,` 2009 I examined and measured the existing roof framing at the 'above' residence for the purpose of determining the structural feasibility of re- roofing with new standard weight concrete tile shingles having a maximum we}ght of 11.0 pounds per `square foot (psf). Structural design criteria includes: building code is 2003 International Residential Code (IRC) as amended by the local building,juiisdiction; snow load of 30,psf; wind speed is 100 mph, exposure C; seismic zone B. The existing roof framing consists of all 2 x 4 W, mono, and special trusses with a 24" spacing, top chords sloped at a 4:12 pitch, and spans up to 301-6 between supporting walls; at the front porch, there were 2 x 6 rafters with a 24" spacing, a 4:12 pitch, and a 71-0" span between supporting walls and a double 2x10 beam, supported on 4x4 beams. Mr. David Benjamin saw a 1130/45" loading stamp on a few of the trusses, and I performed computer analyses on several; of the special trusses and on portions of the roof framing.' None of the trusses described above will be overstressed under maximum load conditions except for three (3) all 2 x 4 modified queenpost trusses spanning 301-6" across the front of the garage; the overstressing is due to the 3211 spacing on those trusses; accordingly, I recommend that new 141 long No. 2 or standard grade S-P-F 2 x 4 sister members be installed onto one side of the top __chords__using 16d_._nails at._a 6"maxi mum_.,spacing -mum.spacing..as shown in the attached Sheet No. 1. Engineered for the way you build Designed for the way you live. The 4x4 beams supporting the double 2x10 porch beams will be overstressed under maximum load conditions; accordingly I recommend that new 3-1/211 x 3-1/211 x 3/8" angles be attached to^ one side of the 4x4's, secured with 3/8" x 3" lags at a 1^,211 spacing. The angles should be long enough to be above the supporting column and run to the house wall. Support the house wall end of the 4x4/angle with a strap passing under the beam and secured at two legs to the wall studs above. At the south 4x4, attach a 1-3/411 x 3-1/2" laminated veneer lumber (LVL) member to the 4x4, secured with 16d nails at a maximum 6" spacing. The double 2x10 beam with the longest span, at the south end of the porch, will be overstressed under maximum load conditions; accordingly I recommend that a new 2x8 be attached to the back side of that portion of the beam, secured with 16d nails at a maximum 6" spacing. It is my experience that most contractors know how to install the above reinforcement; they can certainly contact our office for clarification and answers to questions. There is a likelihood of over 3/4" of deflection of the roof framing under full 30 psf snow load conditions, which may result in cracks in the drywall, particularly at the taped joints where the interior partitions meet the ceiling. Some of this deflection may occur as soon as the tile is installed. Other cracks and deflections may occur under snow load conditions, because the maximum mandated snow load is twice the assumed dead load for the weight of the building materials. Per our analysis, the calculated deflection will be within the limits of deflection as specified in the 2003/2006 International Building Code. It is my opinion that the existing roof framing will be able to support any new concrete tile shingle having a maximum dead load of 11.0 psf once the additional reinforcement specified above has been satisfactorily installed, provided that the existing shingles are completely stripped off and provided that the new shingles are installed according to their manufacturer's specifications. Because I am specifying shingles by weight rather than by brand name, it may be necessary to include product brochures with this report when submitting it to the Wheat Ridge Building Department for a re-roofing _permit,__ so that they can relate the brochure and the maximum dead load weight we have approved for the re- roofing installation. To serve the best interest of all parties involved, I require that you contact our office so that we may inspect 'the finished repairs at the owners expense ($150.00) for compliance with this report; we will provide a letter to you approving the repairs upon proper completion. Failure to do so relieves Crown Jade Design and Engineering, Inc of any and all claims arising out of failures related to improper reinforcement installation. May I remind you that most building departments require a building permit for roof reinforcement work in addition to the building permit required for installation of the new roof; certainly contact your building department prior to installation of the roof reinforcement. Inasmuch as the site review of an existing structure for the purpose of observing the structural conditions requires that certain assumptions be made regarding existing conditions, and because some of these assumption may not be verifiable without expending additional sums of money or destroying otherwise adequate or serviceable portions of the building, the client agrees that, except for negligence on the part of the Engineer, the Client will hold harmless, indemnify and defend the Engineer from and against any and all claims arising out of the professional services the Engineer provides. If conditions not identified in this report are discovered during subsequent inspections or repair work, this engineer should be contacted for appropriate re-evaluation and recommendations. Thank you for retaining our firm to perform this structural evaluation service. Very truly yours, MARK BENJAMIN, PE, SECB Certified in the practice of structural engineering Copies: 4 (Provide 3 copies to your roofer for distribution) (Or provide 1 copy to the homeowner for their records) Attachments: one STRUCTURAL ROOF FRAMING REPAIR REPORT Job No. KLMl-09164 ~P~O°°REOST o~ •~•BEN~~•.~~ v e°°. ~o Date signed' October 21, z. W : 383 ~ r Cindy Klammer FSS°°° 3200 Routt Street ZONAL Wheat Ridge, Colorado 80033 Re: Structural roof repair observation at your residence at 3200 Routt Street, Wheat Ridge Dear Ms. Klammer• On October 18, 2009, for the purpose of inspect specified in the Structural' dated 'October f1, 2009. installed satisfactorily. the above address zforcement work as d Evaluation Report as designed were It is my opinion that the existing roof framing will be able to support any new concrete tile shingle having a maximum dead load of 11.0 psf now that the additional reinforcement' specified in the aforementioned report has been satisfactorily installed, provided that the existing shingles are completely stripped off and provided that the new shingles are installed according to their manufact- urer's specifications. Thank you for retaining our firm to perform this structural evaluation service. Very truly yours, MARK BENJAMIN, P. E. Copies: 2 Engineered for the way you build Designed for the way you live. 3 a ~c2<ra C, e I/ fA f E>~~~.f ~f r ✓~N Y ~ B.~^' " J/s ivi.:Y,9 ~ 1/~.f~ ~.f~~ 'Y, 'mom 14 %jt G 4, J JJ G f City o£ Wheat Ridge Residential Fence PERMIT` - 080660 ~ ~.-080660 ~ p ~ ISSUED: 06/16/2008 ~EXPIRES: ~ 12/13/2008 ST. 3200.ROUT Q' gfi~;~~CJ~3«, Relocate 100' fence (south), repair 40' of fence (East) *v~r WTACTS pwta~r, ~03/233-9485 Beter f. Klammer Cynthia L. Klammer ~I*7F0. ~ . ZOJs'~`` CYSIt~i " UA . . , USE: U SM~~;~4~I$i: ~ 0660~ BLOCK/LAT#: 0/ ~ . . ESTIMATED PROJECT VALUATION: 1,680.00 , ~ . FEES .M-Nin- *N . 78.19 ~ - P1~Yt RBiV'~.ew Fee~~ . ~ . 50.82"~ ~ . . TatY#14~dh,ltzation . ~ ~ ~ . 00 ~ TSo4 144. : . : . 30.24 ~ . . - 159.25 ~ Cdri6tiL19p5:- . . . . J!i 4~AX:Fatsce cannot exceed 4' in front yard (ROUtt St) and cannot exceed 36" in 8}o; ~iaxzgle per 26-603. Both areas shown on propoaed plans per comments. x haE{,~^pryXklPy thatthe aetback 8ietacicee propoeed by thie pexmit application are accurate, and do not violate applicable pyr~~nee#; xtil.ee or reglllatione of the City of Wheat xidge or covenante, easemente orrestrictione of record; tha[ all £ MsA~bshown, and aliegationa made are accurate; that I have read and agreeto abide by all condieiona printed on thie dp~*C"00 , d that I ase e.full reaponsibilityfor compliance with trie.wheat Ridge euilding Code.(I.S.C) and all otherC d9efor.work under Chie permit. P ane subject to field inepection. nt ac te y,'I 44m1C wae iaeuedin'accordance with the provieiona eet forth.in yourapPlication and ia eubjece to the.laae ofthe 11CaS6.af Cqlorado and to the Zoning Regulatione and Building Codee of wheat xiflge, Coloradoor any othez applicable ~Ba'of the City, g,~}p ehall expire 780 daye Faom the Sasue date. Requeete for an extension muat be recelved prior to espiration ~s~e4e, 'An:ezteneionmay be gsanted at the diecretion of the euilding Official. 3, it ~io't p;y'lnit expirea, a new pezmit may be acquired for a fee of one-half the amount normally required, provided xw been..or will be madg in the original plane and epecificatione and any euepeneionor abandonmen[ has not 3¢*&q0464 pne (1) year. I£ chan9es have been or if euepenaion or abandonment exceeds one (1) year, fu1lEeeeehall {dY..a. new permiC. ' q_ ~~Ip`Mp~jC Gf'any manner nhall be done that will change the natural flow of water caueing a drainage problem. 5'. `omtioCt4r.ehall notify theBuilding.Inspector twenty-four (24) houra in advance for all inepections and ahall receive;yCki'Rft~ ap proval on Snepection card befoze proceedin9 with eucceeeive phaees of the job. 6. '~1e S~U11aee of a permat oz the approvalof drawinga and epecificationa ehall not be conatrued tobe a permit for, nor jR yuvai of,any violation of he proviaione ot the building codea ox aRy other ordinance, law, rule or regulation. 'A4 Pldn review ie eubje 'f' inepectione. giypsEuYTN!` CniefBUllCin ff'al date ~ ~&qYli ~ RBQII$ST LIDTS: (303)234-5933 BUILDING OFFICE: (303)235-2855 a~ ~MRSTBEMADEBY3PMANY HTSSINESS DAY FOR INSPECTION THE FOLLOWING BUSINES9 BAY•^ . . . . . . . . . ~ „ , . . ~ i r % . _ . 5✓. 8 M1Y~S' ~ COMMUNITY DEVELOPMENT DEPARTMENT oa ""EqT BUILDING INSPECTION LINE - 303-234-5933 : q'o CITY OF WHEAT RIDGE ~ m 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) °~coePO° APPLIGA Building Permit Number: ogbapo ~ Date: b//~ `o g l Property Owner: Peter F. Klammer and Cynthia L. Klammer Phone: 303-233-9485 Property Address: 3200 Routt Street Contractor License No.: Phone: Company: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Buildinq Dept. Va/uation Figure: I hereby certify that the setback distances proposed by this permit application are Va~lle:$ accurate, and do not violate applicable ordinances, rules or regulations of the City of W heat Ridge or covenants, easements or restriciions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all PEril]lt FOE:$ ~ conditions printed on this application and that I assume full responsibility for Plan ReV1eW Fee:$ .7v' ~jeZ RidgellOrdnanceseforwe ork RidderthispermrttlPlalossubj cttoofedapspectionWheai USe'('aX: Total:$ (OWNER)(COMRACTOR).SIGNED - - (OWNER (69NTW~T9R):PRINTED_PETER F. KLAMMER DATE Use of Space (description):_ Fence, lot south side on 32n° Ave. _ Description of work: Relocation of approx. 100' of fence, out approx 6' (south) towards de'w h prof le street (drawings attached); also repair of 30' of fence in place s modification (d?2+K`s attached). Sq. Ft. addetl _ n/a _ P h~ BUILDING DEPARTMENT USE ONLY SIC: Sq. COMMENTS: a T ~ I Llcf ApprovaCJ~}-O~ ~c(lra(oB- fru`~ CakNOf CkCecO In ~~orn~L 4ar (MUi„ Zoning:t'I O.Nd CP4W+ t.trCted 3tn'k iA f(Sh~ fiiav)fe QP'"ZCn-6( d,t(~ evcFr sG~~ a.~ "p.,po~~d" ~O(4NI perco~rMe~9 G COMMENTS: Approval: W ORKS COMMENTS: Approval: IRE DEPARTMENT COMMENTS: I I Approval: 10ccupancy~ Walls Roof Stories Residential Units: Electrical License No: Plumbin9 License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval Approval (1) This permit was issued in accordance with the provisions set foAh in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the Cily. (2) This permit shall expire if (A) the work authorized is not wmmencetl within sixty (90) days from issue date or (B) lhe buil ing authorized is suspended or abandoned for a period of 180 days. (3) If ihis permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector hventy-four (24) hours in advance for all inspedions and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed lo be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject to field inspections. Chief Building Official 006 125 00 86-20385 ReEsPOM L A N D S U R V E Y 1 N G 5460 WARD ROAD • SUITE 760 ARVADA,COLORAD080002 (303) 420-4788 IMPROVEMENT LOCATION CERTIFICATE Attn: BRIAN/PETE Note: Conc. & Shed in Easement as Shown. Conc. Retaining Wall / Found LOT 2 / Pin n~ Y7._.._.._.._.._.._.._.._.._.._.. N Scale: ] "=20' O ~ 0 ~ d ~ 7 0 N M Excepted Podion (Legal) 134.16 Conc. DATE ~~t 12I z FEE • JOB# CLIENT BRIAN ut.nnrt-Icg ADDRE55 3200 ROUTT STREET NAME KI.awnwcg LEGAL DESGRIPTION tvea cuervv F SEE ATTACHED ~ LEGAL DESCRIPTION I~ J 5' Easement (Plat) _ ~ 10'x 12' ~ Frame Shed I I I 21.0 j I U N o: ~ c'4 'U; ~ ~ 63 ~ Two Story I Brick & Frame I ~ I ~o I a r' ~ 09 Conc. M m ~ I W I o I I 29.1 I I ~ ~ LOT 1 ~ I I a ~ I _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J 10' Easement (Plat) Existing Fence (Approac.) .~..~_.~..-.._,~...._,-...r:134.034._.._.-...l.r.,..~._.t o Vacated Portion of West 32nd Avenue Rec. No. 93155172 (Legal) °O f124.2 West 32nd Avenue On the basis of my knowledge, information and belief, I hereby certif ent location certificate was prepared for BR=pN KT,,10,t,.g not a Land Survey Plat or Improvement Survey Plat, and that it is not e relied upon for e establishment of fe e, bu ' g, or other future improvement lines. 1 further certify that th mprovements on th above described parcel o this da ,except utility connections, are entirely within the bound es of the parcel, exc t as shown, that there are nis encroach nts upon the described premises by improvements on a adjoining premises, e ept as indicated, and that the no apparen evidence or sign of any easement crossing or burdeni any part of said parc I, except as no~~t~eptd~. "NOTICE: According tq Colorado law you mu t commence any legal ion based u erry~ ~bl ' this survey within three y rs a/ter you /irst discover sucA~ defect. In no event, may any a' n based upon any deI ct in this s~c lnore than ten years Iro the date o/ fhe certification shown hereon." J~ ~:'2 e!! FiO~~~. 23.4 r------- I ~ . Conc. Dme 1 I ~ 1 I S o ~ J N ~ I I U ~ i ~ I 9.0 C, I I o a: , ~ ; o Y I ; O U ~I I N W I : O ' ( I I I I I L_ _ _ \ ~ - 10.0' 0 ~ NOTE: SUMEYI6DPIWNUSIN6 27LW ~ f•7'J~2{~O. ~ runeoArwLeson c---r--'"y~,~" BEAPIN081NODIMENSIONS Rohert E. Port. I:aS?.'~5321 Or R04@GE~n. Xayden, L.S. 272 d REVISIONS ZONE I REV I DESCRIPTION DATE APPROVED -117 s -Il;- J ~ Section A (typ.) East View Section B East View 0 k L 7' 1 C, ~~~'f ~P N C.Q i fi 6+.'Jtc ~ C'?: C CC G jk:~e t SIZE I FSCM NO. SCALE DWG NO. SHEET REV REVISIONS ZONE REV DESCRIPTION DATE APPROVED m m B I I 0 i A errace eve above awn gra e Terrace at sidewalk grade 4' above lawn o l \ ~ -a ~ c rock at sidewalk grade an of Pro perty to o u n d a r Proposed P ivacy Fence (re(ocated 6' tow 32nd Ave.) Sidewalk 32nd Ave, B A I SIZE FSCM NO. DWG NO. REV SCALE SHEET 41 r-0 I®'5 REVISIONS ZONE I REV I DESCRIPTION DATE APPROVED 1) / _I7-~ 1' - 9 " Section East Vi A ew ,_9„ Sidewalk 32nd Ave, Property Boundary Yp walk 32nd Ave. dary SIZE I FSCM NO. DWG NO. REV SCALE I ISHEET section -n East View REVISIONS I ZONE I REV I DESCRIPTION DATE I APPROVED ,r 0, 0 of slEeen~k s~oae 'rr SMemlk 32M Ave. 0 10'-9' Section A (typ.) East View 11 46- 6' Section B East View MIa cock It eltleealk Bratle SIZE FSCM NO. SCALE DWG NO. SHEET REV ~'~iHE4TN ~ City of Wheat Ridge ~~~oRa~ Residential Plumbing PERMIT - 070113 :PERMIT NO: 070113 ISSUED: 02/15/2007 JOB ADDRESS: 3200 ROUTT ST EXPIRES: 08/14/2007 DESCRIPTION: Replace water heater with samemodel. ***CONTACTS owner 303/233-9485 Pete Klammer PARCEL INFO ZONE CODE: UA USE: R-3 SUBDIVISION: UA BLOCK/LOT#: 0/ FEE SUMMARY . ESTIMATED PROJECT VALUATION: 530.00 FTE3 Permit Fee 34 . 52 . . Total Valuation .00 Use Tax 9.54 . TOTAL..**. 44.06 Comments : pOM94fumace6 • MYnimum ai ~°~D ~ in ~tsw Minimum of 90°+6 AFUE g~CR TI~ mWirgd (Fxcept fai HydroniC HIMO ~ . Mp~rt~Nn of .80 Ener9Y FSCW EN~cak M~NMW FIeNeM. MinirywMn d.93: n~ F,e~ lklls ~ a R_~~g~gp~pN • R-21 V m R-19 BtMmsM wallt I hereby certiEy that the eetback diatances propoeed by this permSt application are accurate, and do not violate applicable ordinancee, rulea oY regulatione of the City of IVheat Rid9e or covenante, easementa or restrictions of rewzd; that all measuremente shown, andallegatione.made are accurate; that I have read and agree to abide by all conditione printed on thie applicatiyAyand ap I~/~eeume full reaponsibility for tompliance with the Wheat Rid9e Huilding Code (I.H.C) and all other __......~wf✓w.ea/eaa6.wrnalfancee. for work under thie permit. Plana euEject to field inepection. of date 1. Thie pexinit wae issued in accordance with the provieiona eet forth in your application and is subject to the lawe of the State of Colorado anU to the Zonin9 Regulatione and Huilding Codes of Wheat Ridge, Colorado or any other applicable ordinancee of the City.2. Thie permit ehallexpise 180 flaye from the iseue date. Requeete for an extenaion muet be received prior to expiration date. An exteneion may 6e granted at Che diecretion of the Suilding Official. 3. If thie permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changea have tieen or will tie made in the original plane and apecificationa and any euepenaion or abfullnfees ehaell c exceeded one (1) yeac: If chaagea have Deen or if auepenelon or abandonment exceede one (1) year, . . be paid for a new permit.4. No work ofany manner ahall be done that will change the natural flow of water caueing a dzainage problem. 5. Contractor ehall notify the Building Inepector twenty-four (24) houre in advance for all inepectione and ehall receive written approval on inepection card before proceeding with eucceeeive phaeee of the job. 6. The iaeuance of a permit or the approval of drawinga and epecificatione ahall not be conatrued to be a pexmit for, nor . an approval~of, any violation of the provieione of the building codee or any other ordinance, law, rule or regulation. . All plan revigy_ie eubi ~'^ld inspectione. Signa ui al date .TNSPECTIONR8QIIE3T LINS: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST SE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION TAE FOLLOWING BUSINE55 DAY. COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: oF W"Eqr,~ BUILDING INSPECTION LINE - 303-234-5933 Date: ~ a CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE j~LAN # WHEAT RIDGE, CO 80033 - (303-235-2855) MlNf?R AFP'LICATIC7N Proper[y Owner: /I Proper[yAddress: Phone: 3P- 277- 4fY,?5_ Contractor License No.: eJW-'fteu - ~ 13 Company: Phone: 3~ ~ A/6 OWNER/CONTRACTOR SIGNATURE OF UNDERS7ANDING AND AGREEMENT I Buildinq Dept. Valuation Figure: $ I hereby certify that the setback distances proposed by this permit application are accurete, and do not violate applirable ordinances, rules or regulations of the City of W heat Ridge or covenants, easements or restrictions of record; ihatall measurements shown, and allegations made are accurate; ihat I have read and agree to abide by all conditions printed on this application and that I assume full responsibilily for compliance with the W heat Ridge Building Code (I.B.C) and all other applirabte W heat Ridge Ordinances, for work under this permit. Plans subject to field inspection. (O W NER)(CONTRACTOR): (OWNER)(CONTRACTOR):PRINTED DATE Value:$ Permit Fee:$ ~ Plan Review Fee:$ Use Tax: Total: $ Use of Space (description): Description of work: A~~~~ Sq. Ft. added Expiration Date: Expiration Date: Expiration Date: Approval• Approval: Approval: (1) This permit was issued in accordance with the provisions set forth iayour application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been orwill be made in the original plans and specifcations and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector hventy-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drewings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of lhe building codes or any other ordinance, law, rule or regulation. All plan review is subject to field inspections. Chief Building Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUfLDING INSPECTION DNISION - 235-2855 - CITY OF YVHEAT RIDGE Date : 7500 YVEST 29TH AVENUE WHEAT RIDGE, CO 80215 PmPerty Owner : A ~ c- f''~ .o~ . . • Property Address : i ,~47C Phone: eZ 3 Convactor License No. 7/ f-:2, Company :t cis t~~~~ <%"9 -Z; c- Phone : S'3!/ 0 8'sr'/ rt OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMEM I nsrsbY certi(Y tnat Ne sstbatlc Oisbnps propoae0 by fhis pemmt appuution an aceunte. antl Oo not vbWa aoouabM orounneas. nASS amguworo ot tM Cily W Whon Ridp a- wvgnarro. aassmsma a rtstnctbns of rimiu: Mat a0 ms=wr"Wu shown. ana aMSpMons rmsm us sowratr. tnat I haw nb an0 ro abtlo ey w mn0tlioiM On~d on Wi appYCafion. ano that I asfmne fuN nfor oom0~o~ wih IM YMNR RWp 9utdMg CaW (U.B.C.) ana all qha aDpCabli WflM PJdgs or~im~nanom . br~w~ak undvMS PrmK. (OWNERxCONTRACTOR) SIGNED/O~a-+ ,~~Cs.+/Gi✓ Ou1TE Construction Value : y'7 4" Permit Fee : z ? SD Uae Tax :5P'0'-s a°-mvrs 7otai : g3 Descripdon :/eP/r ~e ~ 1..~ /fvo '~•i- ~/'r•ed r~'o/' i n~•c i/.•e.~ I ZlMMLEE'dtSflf8 APProval : Zoning : ~~Illl APPruval - Fw ~ Appreva! : Occupancy : Walls BUILDING DEPARTMENT USE ONLY Roof : Stories : Residenbal Uni4s : Electncal License No : Company : ExpiraGon Date : 4pproval: ~Pl(ns'Riqu(red ;~n ~ - Plumbing License No : Company: Expiretion Date : Approval : 3 - PIffifs Riiqutrod - Mechanical Licenae No : Company : Exptradon Date : Approval: jiftsm! . ~ rp ; t) Thu aermt was usuea m umoano wm eq pwmans $M lwvi n yopur aopRaoon ano is s~p~u b tnt I~ws W IM StW W Cobraao ana ~o er Zowq RspWauons ane Buiavg Coaa m wnaal RiCO~. Caoraoo a airy an6r aopkaaw aawnns ot me Ciry. ; 27 T1us wnyin snau uws e (n) tne won aumansao u na mmr»rrea vnoun xnY (60) Oari hom nsw 4n a (8) IM baWUq SuNdisw n twpnaW or aevwonaa ior a oarqo ot 120 0ari ;a) u tni oamn oxwros. a now ovrtn mmy oe +eaurw ar a tN W on►Mx Nw affiwnt normaW rwuna ao„M m Cuiqes naft uwi orwi o@ n M wq+W oura ana aoscAlaoons ana +nv auMaMwn a swnaoiwnwm nas na exeswa one o) »+r• pmmOe wn mwO a d wipwroqn a sbrbomwt esoeoas aw i t I rw. nA ha+ wll a ow ar a N. eom11t. No wOtlt Of inY IIYnI1H ft1iN Of OOM Qitl W W C1i11ge OM NNfL OOw OIWSM tJYLnq a OI7YN9s VODMII. : s) cono-accor snan nonM tne Bu+anq imwcsor ti"nry•wur (24) noun M sovana ror an mspeaons ana ~nu r~w wnq~n appmM on wpermn am eNa~ ytopa0anq wM s~ssrve Wltias Of Me p0. '.6) Th! 43ulnCe Of i ORRM Of N! i0 W Wi1 d Cr&r'inQi in0 SOQO(K1f10f13 SIN4 nOt Df COl13tN00 t0 De i p01f1111 fOf. Ilpf RI !{IpIm101. illy NdaOM 01 Vlf 0mmqlli O! CI! DWIORg NOGS Or iOy ONlt OrCRqnCt. wW. N:! Of ll9WUM- Chief Building Inspector-- For Mayor TNIS PERMlT VAUD ONLY WHEN SIGNED BY THE CHIEP BUILD(NG INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 10401 BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE Date : 4/19/00 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner : Property Address : 3200 ROUTT ST Phone : 233-9485 Contractor License No. : 17152 Company : Precise Plumbing Phone : 534 0881 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are aaurate, and do not violata applicable ordinances, rules or regulations of the Ciry of Wheat Ridge oi covenants, easements or restrictions of record; that all measurements shown, and allegations made are 8ccurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Coda (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this pertnR. (OWNER)(CONTRACTOR) SIGNED DATE Description : Replace water heater, ready for inspection Construction Value Permit Fee Plan Review Fee Use Tax Total $475.00 $23.50 $0.00 $0.00 $23.50 Use: BUILDING DEPARTMENT USE ONLY Approval : Zoning : Approval : nommigoommom Approval : Occupancy : Walls SIC : Sq. Ft. : Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval : Plumbing License No : Company : Mechanical License No : Company : Expiration Date : Approval: Expiretion Date : Approval : (1) This pertnit was issuetl in accortlance with the provisions set fodh in yopur applicaUOn and is sub1'ect to the laws of Ue State of Colora0o antl to the Zoning Regulations antl Buildinp Code o( Wheat Ridpe, Colorado or any o[her applicable ortlinances Mthe City. (2) This pertnit shall e~cpire if (A) the work authorized is not commenced within sixry (80) Cays hom issue date or (B) ihe builtling authorized is suspended or abandoned for a periotl of 120 tlays. (3) If this pertnit expires, a new permft may be acquiretl for a fee of one-half the amaunt normally required, providetl no changes have been or will be made in the original plans and specifications and anysuspension or abandonment has not exceeded one (1) year. If changes are made w'rf suspension or abantlonment exceeds one (1) year, tull fees shall be paiA for a naw pertnit. 4 No work of any manner shall be done that will change the naturel Flow of water causing a tlrainage problem. 5 Contractor shall noti the Builtling Inspedor hventy-tour (24) hours in aCVance for all inspections and shall receive written approval on inspection card before proceetliing wiN ssive ha of the 1~ob. (6) The issuan i roval ot tlrewings and specifications shall not be consWed to he a permR for, nor an epproval of, airy violation of the provisions of the building de r a rdinance, law, rule or regulation. Chief Building Inspector . 40 DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number : 10401 Date : 4/19/00 Property Owner : Property Address : 3200 ROUTT ST Phone : 233-9485 Contractor License No. : 17152 Company : Precise Plumbing Phone : 534 0881 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurete; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibiliry for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat ftidge ordinances, for work under this permR. (OWNER)(CONTRACTOR) SIGNED DATE Description : Replace water heater, ready for inspection Construction Value : Permit Fee : Plan Review Fee : Use Tax : Total $23.50 $0.00 $0.00 $23.50 Use : BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval : Plumbing License No : Company : Expiration Date : Approval : Mechanical License rvo : Company : Expiration Date : Approval : (1) This permit was issued in accordance with the provisions set torth in yopur appllcaUon antl is subject ~Ne laws of Ne State of Cobredo and to the Zoning Regula6ons and Building Cotle of Wheat Ridge, Colo2do or any other applicable ordinances of the (2) This pertnil shall expire if (A) the work authorized is not commenced within sixry (60) tlays from issue date or (B) the building authorizetl is susperMed or abandonetl for a penotl of 120 days. (3) If this permk eupires, a new permit may be acquiretl (or a fee of one-half the emount nomialy required, provitled rw changes have been or will be made in t e on8inal plans and specifications and any suspension or abandonment has not exceedetl one (1) year. If changes are made w d suspension or abandonment exceeds one (t) yeer, full tees shall be paid for a new pertnit (4) No vrork of any manner shall be done that will change the natural flow of water musing a tlreinage problem. (5) Contrector shall noti the Building Inspeclor twenry-four (24) hours in advance for all inspec4ons antl shall recelve written appmval on inspeotlon card before proceetliing with s srve has oF the 7ob. (6) The issuan e ita~al of drawings antl speciflcations shall not be consWetl to be a pemnk for, nor an approval of, any violation of Vie provisions of the builtling . es r a r rtlinance, law, rule or regulation. Chief CE?AS2TMENT aF COMMUNITY DEVELOPMENT 7500 WEST 29tn AVENUE BUILDING INSPECTION DIVISION PERMIT N0. MM91#3235 237-8944 ExT. 255 P.O. BoX 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED BEL'JW. l~~LI~"ATI6N FOR MISCELLANEOUS ERMIT JOB ADDRESS \ 1 OWNER %~/A /iifr; CONTRACTOR Rod Aall Co. ADDRESS;-',;,~i?jJ ADDRESS 2$5 WyaIIdot St. PHONE ZIP COOE ~13 CITY 71apVer ZIP CODE 80794 ~ CONTRACT PRICE $ PHONE LICENSE 1. TYPE GrounE❑ Woll❑ ProiecfinQ❑ 01hN SaDFao1 SIGNS 2. MATERIAL 3. ILLUMINATION Yea❑ No❑ Typs Total Squore Fatt . Eleef. Psrmit No. 4. SET BACK fROM PROPERTY LINE N__ (Spxify whiCh ia f ront ) ❑ 5_ E ❑ _ W ❑ ❑ Zone_ Approvad,Zona Inspeetor DiaapDrovsd 1. 7YPE Solido Mora Than 80% Opan❑ Less Thon 80°/a Open MATERIAL Heipht FENCES 3. SET BACK FROM PROPERTY LINE N_ S_ E _ W Zme_ ApprwM,Zons Inspscfw (Spseify whiehie tronf) ❑ ❑ ❑ ❑ Dieopproved I, Install R. H. Peterson as lo s ICBO 2399 rr' OTHER 2 3. DRAW SKETCH OR SHOW BELOW,THE FENCE, SIGN, OR OTHEF (SETBACKS OR PROJECTIONS INCIUDED) PERMIT FEE Joe 2vtJ /27` ~ ADDRESS v v 3 M /-`f / DATE: BLDG. PERMITB 32-3S IFY NORTM USE TAX PERMITM BLDG. CONTR. 1`0W 17 n 51REET N4ME SHOW DISTANCES FROM THE MAIN BUILDING TPAOJOINING HO DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERA APPLICATIOPI FOR PLUMBII THIS APPLICATION WILL BECOME A PERMtT TO PERFORM THE i t.f''.@AIT WiLL EXPIRE 60 DAYS FROM DATE I TOTAL FEE ELECTRICAL PERMIT STATE UCENSE N0. F qEMARKS C/ ERMIT STATE LIf nLUMir;Lroa WIRF. UPIDEF SIXE @ ILLHGAI FLOOR ropone Elee Sdor N0. WATER CLASETU TEMPORARY METER WASH 80WL TU NEW SERVICE AMPS BATH TUB W.B. FORM 619 TU CHANGE SERVICE-AMPS SHOWER TU LIGHTIN~ SINK HEATING GARBAGE DISI C/ EM POWER SUB-CIFCUITS WATER HEATE UTIUTY(RAN6E,DISPOSER,ETC.) AUTO.WASHEI. FIXTURES DISH WASHER AUTOMATIC SPRINNLER SVSTEM WIRING MOTORS d CONTROLS F100R DRAIN EIEYATOR SIGNS URINAL 1RANSFORMER5 9 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES I hsreby acknowledpe ihot this applico- tion ia correct and understand thot I cannot ifoit tAis project until thin oppli- eofion it approved. I shall comply with the lawa of the Stote of ColoraEO ond to the Zoninq Requlotions ond Buildinp Code of the City of Wheat RidQe. Any violafion of the above ferma will couse immadiafe revocotion of this permit CHIEF BUILDING 115 INSPECTION TICKET SUBCONTRACTOR DATE INSP. REQ. MLFAST TYPEOFINSP. G~5 '41? A 6 c., INSPECTION MADE 4/ _CTION DIVISION. ,Cityof Wheat Ridqe Date Issued NOT /3sl/ CAL1237-8944 EXT.255 24 HOURS IN ADVANCE FORINSPECTIONS Aovlieanb SionePo.o