HomeMy WebLinkAbout3333 Simms StreetINDEX:
S1-1 GENERAL NOTES
S1-2 GENERAL NOTES/LEGEND ON SITE PLANS
S2-1 FOUNDATION PLAN MUST BE ON SITE FOR INSPECTION
TYP. PUSH PIER DETAIL ALL Projects are
Subject to Field Inspections
BUILDER INFORMATION
Complete Basement Systems
11795 East 45th Ave
Denver, CO 80239
720-487-9568
General Notes:
1. Construction documents are valid for a single use at the project location and shall not be reused, copied, or
reproduced without written approval of the registered design professional in reasonable charge.
2. The contractor is responsible for the methods, means and sequence of all structural erection except when
specifically noted otherwise in the construction documents. The contractor shall provide temporary shoring and bracing,
providing adequate vertical and lateral support during erection. Shoring and bracing shall remain in place until all
permanent members are placed and all final connections are completed.
3. The contractor agrees that, in accordance with generally accepted construction practices, the contractor will be
required to assume sole and complete responsibility for job site conditions during the course of construction of the project,
including safety of all persons and property. This requirement shall be made to apply continuously and not be limited to
normal working hours. The contractor further agrees to defend, indemnify and hold owner and engineer harmless from
any and all liability, real or alleged, in connection with the performance of work on this project, exempting liability arising
from the sole negligence of engineer.
4. All existing sizes, dimensions and foundation damage shall be field verified by the contractor and owner prior to
construction. Discrepancies with the construction documents shall be reported to the structural engineer for additional
recommendations (if any).
5. Per the owner's request, the contractor shall stabilize the structure only. No attempt shall be made to lift or plumb
the foundation wall without approval for the owner and structural engineer.
Field Verification:
1. Contractor and Owner shall thoroughly inspect and survey existing structure to verify dimensions, elevations,
framing, etc. which affect the work shown on the drawings.
2. Report any variation or discrepancies to the structural engineer before work proceeding.
Design Criteria:
1. Building code: 2018 IBC, 2018 IRC with City of Wheat Ridge Amendments
2. Dead loads
2.1. Roof 20psf
2.2. Floor 12psf
2.3. Walls 10psf
3. Live loads
3.1. Residential40psf
3.2. Roof 20psf
CITY OF WHEAT RIDGE INSPECTION REQUIRED PRIOR TO BACKFILL
4. Snow loads
PROVIDE ENGINEER OBSERVATION LETTER AT FINAL INSPECTION
4.1. Roof snow load 30psf
5. Wind loads
5.1 Exposure Category C
J@y E_ oi-
DN:DC "a�-us.Kell O=L
E"IM aABfi BB
O Remo: 14m ADD nw
5.2 135 mph Ultimate Wind Speed
10" = city of
6. Seismic LoadsWheatR�dge
COMMUNITY DEVEIIWi
6.1 Seismic Design Category: B
APPROVED
6.2 Site Class: "D" per USGS
-10 .
Reviewed for Code compliance
7. Soil Bearing Capacity = 1,500 psf (assumed)
Randy Slusser 2/17/2021
Plana Examiner Date
yapdM of oen.r: WW MWWW of a pampor WPMWCfFhM specQlca[Aaee
adaonlpwwws shoo rot be a pematfas ad" aw"W of. ay wiftan m
agofthe wowstmaJmetUWVcodeaofawaraeaefaM& fk4mb
psesammp so pee owo" to r bkw a eaxd Ift ANWONa" CIFrM Aoft
rods a oM+a ardf faaaerW ur afr Map as fx cart
Foundation Design:
1. Soil conditions and types shall be verified by a Engineer during excavation.
2. All helical piles, push piers, helical anchor tiebacks, wall anchor tiebacks and connection hardware shall be
designed and installed by supplier, such that they provide the minimum allowable capacities as indicated on the
drawings. All capacities shown on the drawings are unfactored service loads and have not been reduced for live load
reductions.
3. Design of individual and continuous footings is based on an assumed maximum allowable bearing pressure of
1500 lbs. per square foot (dead load plus full live load), placed on the natural undisturbed soil, or compacted structural
fill below frost depth.
STEEL PUSH PIERS:
1. Grip Tite: Push Pier with sleeve and bearing cap and with FP3BA Retrofit Bracket
2. Install with a calibrated hydraulic ram with known pressure -to -axial -force ratio.
3.. Pier depth is dependent on depth of bearing soil adequate to provide the specified pressure resistance, therefore,
depth is not specified. Pier to be advanced until refusal is attained.
4. Installation pressure serves as empirical verifications of pier capacity, yielding an onsite load test for each pier.
Therefore, soils testing is not necessary for generating a theoretical capacity.
5. Piers shall be push piers, installed at locations shown on the plans.
6. It is assumed the each new pier will achieve penetration into bedrock or competent soil, and can be installed to
the specified capacity. Should bedrock or competent soil not be reached within reasonable depth this office should be
notified for further instructions.
7. Contractor is to maintain accurate pier depth and pressure / torque charts for each pier, showing depth and
pressure / torque at each shaft section. Charts shall be filled out in real time during installation, and maintained onsite
for engineer review during inspection. Charts shall be provided to engineer in final form upon completion.
Special Inspections
1. Special inspections shall be provided per the requirements in the UES Evaluation Report #391, Section 3.3 as
well as the requirements of the 2018 IBC Section 1705.9.
Cast -in -Place Concrete
1. All concrete design is based on the "Building Code requirements for Reinforced Concrete" (ACI 318-05/318R-05)
All structural concrete shall have a minimum 28 -day compressive strength as follows:
1.1 Footings:3,000psi
1.2 Slab on Grade: 3,500psi
1.3 Foundation walls: 3,000psi
2. Concrete shall be placed on proportioned utilizing Type 1 cement except, concrete exposed directly to soil shall
use Type 2 cement. Concrete susceptible to freeze shall be formulated or maximum frost resistance in accordance with
the ACI manual of Concrete Practice.
3. Cold weather and or hot weather placing procedures shall be provided, if conditions warrant, as recommended in
the ACI manual of Concrete practice.
Reinforcing Steel:
1. All detailing, fabrication, and placement of reinforcing steel shall be in
accordance with the ACI Manual of Concrete Practice.
2. Reinforcing bars shall conform to ASTM A615-79 and shall be
grade 60.
3. Except the drawings,
J@y E_ oi-
DN:DC "a�-us.Kell O=L
E"IM aABfi BB
O Remo: 14m ADD nw
as noted on minimum concrete protection
H sS L -n., s
for reinforcing shall be in accordance with ACI 318-05/318R-05.
c> : �� :20 :moo
4. No. 5 or larger reinforcing bars shall not be re-bent.
: Y 0054409 N
5. Welding of rebar is not permitted unless procedure is approved by
-10 .
the Structural Engineer.
ONAL
=XP. 10/31/21
REVISIONS
DATE
T
N
0
N
CO N
W r
H N
Z 31V(
J
J
W
LI A9
(9 Ji03F
H
14
Z
O e
~ oJ
N
�NVW
urn
a� m
NNO�
Z M 2
O Z
aMWO
ZZ 3
M
O
U.
V IN M O
ZaN U
a0oo�
ZJcc, d4W
�WNU0Z
WW
WG �
Z�~O Z
0OOW
W
ONW~�
o
Q0
JOB NO.
2027-9706
SHEET
SI -11
OF
3
Structural Steel:
1. Structural Steel shall be detailed, fabricated and erected in accordance with 2010 AISC Specification for Structural
Steel Buildings, and "Code of Standard Practices" 2005.
2. Structural Steel shall be confirmed to the following grades:
2.1 W & WT- Shapes: ASTM A36, A992
2.2 Plates & Angles: A36
2.3 HSS: ASTM A500 gr B
2.4 Steel Pipe: ASTM A53 gr B
3. All bolts shall conform to the ASTM A325 except anchor bolts which shall conform to ASTM A307. Bolt Size shall
be %", unless noted otherwise on the drawings.
4. All welding shall be by a certified welder in accordance with ACIS and AWS specifications and recommendation.
Structural Wood framing:
1. Except where noted otherwise, all 2" members shall be Hem -Fir No. 2 and better.
2. Except as noted otherwise, minimum nailing shall be provided as specified in Table No 2304.9.1 "Fastening
Schedule" of the IBC. All nails shall be common type, unless noted otherwise.
3. Unless noted otherwise, steel connectors such as those manufactured by Simpson Company, shall be used to join
rafters, trusses, joists, or beams to other members at flush -framed conditions. Use maximum number and size of nails
indicated in manufactures tables U.N.O. all nails holes shall be filled.
4. All multiple members shall be glued & nailed together.
5. All wood in contact with concrete or exposed to weather, shall be pressure treated Douglas Fir -Larch No. 2 or
equal.
6. Structural members shall not be cut for pipes, etc. Unless specifically noted or detailed.
Periodic surveys:
1. Periodic surveys of the supported structures should be conducted to assure project success. The Owner should be
responsible for annual surveys certifying project success. We would suggest that a baseline survey be conducted
immediately. The owner shall submit all findings and reports to the Structural Engineer.
2. If vertical movement of the piers is discovered, the piers should be re -pressured. A representative of the
Geotechnical Engineer should be present to observe the re -pressuring. A final report should be provided by the
Geotechnical Engineer after observing the re -pressuring.
Foundation Stabilization:
1. Although observed foundation damage typically does not pose an immediate health and hazard risk, delaying
mitigation will likely make future repairs more difficult and costly. Furthermore, it has been our experience that once a
structure begins moving, it will likely continue to so (unless action is taken) resulting in further settling, heaving, unsightly
cracks, doors/widows not functioning properly and possible foundation wall collapse. The extent and aggressiveness of
the foundation repairs should be carefully considered by the Owner and will depend on their tolerance for risk, the
possibility of future damage, and cost.
2. If the owner chooses to do so the foundation could be stabilized only at visibly damaged locations and areas where
movement is concentrated. Although this will address specific situations, it is possible that foundation movements will
occur elsewhere.
3. If the Owner chooses to do so, the entire foundation could be mitigated. A general system repair, although more
costly, would greatly reduce the risk of future foundation damage and movement. It is our understanding that the Owner
would not like to pursue this repair option.
Site Drainage
1. We believe that the moisture around foundation elements must be controlled for the useful life of the building.
Lack of proper drainage is often a contributing factor to foundation damage observed. It is our opinion that site drainage
around the structure must be maintained such that precipitations will quickly drain away. The use of proper slope
slabs -on -grade, moisture barriers, swales and surface/subsurface drainage systems are strongly recommended.
Extension should be attached to properly function downspouts and roof drains discharge a minimum of 10 feet away
from the structure.
Site vegetation
1. We believe that vegetation around the perimeter of structures can eventually lead to foundation movements.
Vegetation can hold moisture in soil and create excessive pressure on the foundation system. In order to reduce the
risk, bushes, shrubs and trees should be carefully removed by an experienced professional. Care should be taken to
not further disturb or damage the existing foundation system.
2. Planters and other surface features which could retain water should be eliminated and properly graded to reduce
the possibility of moisture infiltrating around the foundation. Irrigation systems and excessive moisture adjacent to
structures can introduce unwanted moisture, possibly resulting in settling and or heaving. The Owner should consider
removing irrigation systems or simply not use them.
Disclaimer:
1. In as much as the site review of an existing structure for the purpose of observing the structure conditions
requires that certain assumptions be made regarding existing conditions and because some of these assumptions may
not be verifiable without expending additional sums of money or destroying otherwise adequate or serviceable portions
of the building, the Client agrees that , except for negligence on the part of the Engineer, the Client will hold harmless,
indemnify and defend Engineer from and against any and all claims arising out of the professional services we have
provided.
LEGEND:
(E) EXISTING
(N) NEW
PUSH PIER
P.P. #X PIER #
00004)
LOAD ON PIER
HELICAL PIER
H.P. #� PIER #
(0004) � LOAD ON PIER
WALL ANCHOR City of
W.A. #x ANCHOR # Wheat Ridge
WALL BRACE Building Division
W R #x BRACE #
CARBON FIBER
C.F. #x �- CARBON FIBER #
,
POST•.�oM.P.
sMONO
#x i- POST#
C10N
()LOAD ON PIER�<v�1/2:.
REVISIONS
DATE
T
N
O
N
co R
W
H N
00 31V(
ZZ
w w O
Z
W A8
(7 JiO3F
Q
O eM
N�oJ
N
m 0 v W
fW �
a� m
U)tooiir
On Z
a�WO
ZZ 3
n
LL
v iui eN O
Z aN U
O00 O W
NJ
2WNIv(PZ
W LU
Z1!J~O Z
�OoW
WOyW~�
O �
CO
JOB NO.
2027-9706
SHEET�
S11-2
OF
3
CITY OF WHEAT RIDGE INSPECTION REQUIRED PRIOR TO BACKFILL
PROVIDE ENGINEER OBSERVATION LETTER AT FINAL INSPECTION
(N) P.P. #1
0
2
S2-1 0D
w
(E) HOUSE/
BASEMENT
ih
0
Fl -
3':n
7'-
(N) P.P. #8
(15.2k)
(E) GARAGE/ (N) P.P. #7
SLAB (15.2k)
7' -1'-6"
(N) P.P. #9
(15.2k)
(N) P.P. #10
D FOUNDATION PLAN
1/16" = 1'-0"
NOTES:
1. SEE SHEETS S1-1 THROUGH S1-4 FOR GENERAL NOTES.
2. INSTALL PUSH PIERS PER PLAN.
P.P. #2
(15.2k)
P.P. #3
(15.2k)
P.P. #4
P.P. #5
(15.2k)
P.P. #6
FRONT OF
HOUSE
d
IIIIIIIIIIIII
a
d
•a
a
PP BRACKET d
A
• a
(E) FOUNDATION
WALL
(E) SLAB FLOOR
• I II I I� � �I I I�
c
d. a II III II
° FIELD VERIFY
(N) PUSH PIER,
SLEEVE AND BEARING CAP
P/N: IMG PP21617-34
2 TYP. PUSH PIER DETAIL
C�%NAL
City of
Wheat RidgeBuilding Division
REVISIONS
DATE
T
N
J N
Q
Z � N
0-0 N
Z W 31v(3
0
J
zZ)
Z) a- AS
0 d )iO3HO
LL
Q
O eM
NI...oJ
N
mtovLLI
W �
a� m
U) to Im
ommz
a�WO
zz 3
m
O
LL
v iui eN O
z a N U
43 a00, cs 0
pgWLU
C4U0Z
WW --j W0O 1O
Z~Z
— �OC4 A
oW
zr-
o
wo
C�
JOB NO.
2021-9106
SHEET
S2-1
OF
3
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
2/12/2021
RE: Job# 2021-9106
3333 Simms St.
Wheat Ridge, CO 80033
As requested, a site visit and observation were performed at the property located at the address
above on 2/10/2021 at approximately 9:00 a.m. by Kelly Hoiness, PE. The purpose for the site
visit and observation was to review the structure for movement of the foundation.
The subject property is a single-family home with a finished basement located in an established
neighborhood. The building is assumed to have been built in 1968 (based on an online search of
the Jefferson County Assessors records).
The foundation is constructed of concrete and is assumed to be on spread footings. The house
appears to be constructed of wood with lap siding and partial brick veneer. The observation was
visual and limited to the exterior and the interior house. No observation was performed on the
roof structure. For purposes of this report, we assume that the house faces east.
Observations
• Cracks in the interior finishes, multiple areas on the main level. The majority of the cracks
appear to be on the east side of the house.
• Cracks in the interior finishes, multiple areas on the basement level
• The half foundation wall is slightly out of plumb on the west wall of the basement, near
the south end. There are cracks in the interior finishes in this area and it appears there
has been some slight lateral movement of the foundation wall.
• The basement interior finishes do not appear to be floated
• Cracks in the garage interior finishes
• Crack in the south foundation wall
• Crack in the west foundation wall
• Cracks in the brick veneer on the west wall
• Gaps between the brick veneer and siding on the west wall
• Stepping cracks in the brick veneer on the south wall
• Cracks in the brick veneer on the east wall
• Gaps between the brick veneer and window on the east wall
• Crack in the porch slab on the east wall
• Crack in the foundation on the east wall
• Crack in the foundation on the north wall
• Separation between the front porch slab and foundation on the east wall
1 City of
Wheat Ridge
Building Division
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
Recommendations
The cracks observed in the walls were likely caused by vertical and lateral movement of the
foundation. These movements are most likely caused by contraction and expansion of the soil
due to changing moisture content. The following is a prioritized list of recommended repairs that
should be made to stabilize the foundation:
• There appears to have been differential vertical movement of the house, with the most
prominent movement on the east side of the house. This was indicated by the cracks in
the interior finishes, the cracks in the brick veneer, and the cracks in the foundation.
Install (5) new push piers on the east wall, (1) new push pier on the north wall, (2) new
push piers on the south wall, and (2) new push piers on the south wall of the garage to
help mitigate vertical movement of this area.
• Monitor the half -wall foundation on the west side of the basement for further signs of
lateral movement. These signs may include new or worsening cracks in the foundation,
additional movement of the brick veneer on the exterior, subsiding of soil surrounding
the foundation, damage to the basement interior finishes, and/or moisture intrusion in
the basement. If further signs of lateral movement are observed, the homeowner should
contact DL Engineering for further assessment.
• Monitor the remainder of the home for further signs of vertical movement, particularly
the southwest corner of the house. These signs may include new or worsening cracks in
the interior finishes, new or worsening cracks in the foundation, floors that become more
out of level, and/or doors and windows that become difficult to operate. If further signs
of vertical movement are observed, the homeowner should contact DL Engineering for
further assessment.
• Ensure proper grading and drainage around the perimeter of the house to help prevent
excess moisture accumulation in the soil surrounding the foundation. Doing so help will
reduce soil volume fluctuations and pressure on the foundation. See best practices for
foundation maintenance for additional information.
• Patch and monitor any cracks in concrete, brick veneer, and drywall. This will give a
baseline for any new movement. If new movement is observed, contact DL Engineering
Inc. for further assessment.
• Differential vertical movement of the foundation is caused by several variables which are
beyond our ability to control or forecast. This observation only addresses the areas that
appear to be actively moving and includes recommendations to stabilize these areas. With
any vertical foundation movement, the only way to ensure complete stability is to fully
underpin the entire foundation. The extent and aggressiveness of the foundation repairs
should be carefully considered by the Owner and will depend on their tolerance for risk,
the possibility of future damage, and cost.
Best Practices for Foundation Maintenance
The following best practices are actions to maintain the service life of the foundation that can be
applied to all structures. Proper site drainage and placement of vegetation alone may not prevent
movement of a structure; however, they are prudent steps to avoid the contraction and expansion
of the soil due to changing moisture content. We share the following information, which is not
property specific, with all our clients.
2 City of
Wheat Ridge
Building Division
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
Site Drainage
• The moisture around foundation elements must be controlled for the useful life of the
building. Lack of proper drainage is often a contributing factor to foundation damage
observed. The site drainage around the structure must be maintained such that
precipitations will quickly drain away. The use of proper slope slabs -on -grade, moisture
barriers, swales, and surface/subsurface drainage systems are strongly recommended.
Extensions should be attached to properly functioning downspouts and roof drains such
that they discharge a minimum of 10 feet away from the structure.
Site Vegetation
• The vegetation around the perimeter of the structure can eventually lead to foundation
movements. Vegetation can hold moisture in soil and create excessive pressure on the
foundation system. In order to reduce the risk, bushes, shrubs, and trees should be
carefully removed by an experienced professional. Care should be taken to not further
disturb or damage the existing foundation system.
• Planters and other surface features which could retain water should be eliminated and
properly graded to reduce the possibility of moisture infiltrating around the foundation.
Figure 1: Cracks in the interior finishes, multiple areas on the main level
City of
3
Wheat Ridge
Building Division
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
Figure 2: Cracks in the interior finishes, multiple areas on the main level
Figure 3: The half foundation wall is slightly out of plumb on the west wall of the basement near the south end.
City of
4
Wheat Ridge
Building Division
•2.
G -
OL ENGINEERING, INC.
9100 W Jewell Ave
Lakewood, CO 80232
720-440-9450
www.diengineer.com
Figure 4: Crack in the south foundation wall
Figure 5: Cracks in the brick veneer on the east wall
City of
heat Ridge
Building Division
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
Figure 6: Cracks in the brick veneer on the east wall
Figure 7., Crack in the foundation on the east wall
City of
Voeat Ridge
Building Division
—� 9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
In as much as the site review of an existing structure for the purpose of observing the structure
conditions requires that certain assumptions be made regarding existing conditions and because
some of these assumptions may not be verifiable without expending additional sums of money or
destroying otherwise adequate or serviceable portions of the building, the Client agrees that,
except for negligence on the part of the Engineer, the Client will hold harmless, indemnify and
defend Engineer from and against any and all claims arising out of the professional services we
have provided.
If you should have any further questions, please feel free to contact me at (720) 440-9450 or
khoiness@dlengineer.com
° a
Sincerely,
Kelly Hoiness, PE
C)
Y N:
0054409
�SS��NA� EAG\
EXP. 10/31/21
City of
Wpeat Ridge
Building Division
From: no-reolv(alci.wheatridae.m. us
To: CommDev Farm is
Subject: Online Form Submittal: Foundation Repair
Date: Friday, February 12, 2021 10:55:41 AM
Foundation Repair
This application is exclusively for FOUNDATION REPAIRS.
YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR
THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
Foundation Repair?
PROPERTY INFORMATION
Property Address 3333 Simms Street
Property Owner Name Buehler, Kelly
Property Owner Phone 713-315-1415
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email
Address
Attach City of Wheat
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
kelly@buehlr.com
Wheat Ridae Payment Form 3333 Simms Sj=
CONTRACTOR INFORMATION
Contractor Business Complete Basement Systems
Name
Wheat Ridge
Contractor's License
Number (This is a 5 or
6 digit number for the
60125
City of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-
4567)
Contractor Email
Address
720-507-2711
cbs.permits@completebasementsystems.net
Retype Contractor cbs.permits@completebasementsystems.net
Email Address
DESCRIPTION OF WORK
Location of Work North, East and South Foundation
How is repair being push piers
done? Piers, strips, etc.
# of Piers or Strips 10
Upload engineer letter
or pages on 8 1/2" x
11" only
Repair Plan Set on
11'x17" only - if
applicable
Obs Letter 3333 Simms St.odf
Project Value (contract 11900
value or cost of ALL
materials and labor)
10 x $1,250 = $12,500 Valuation
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
Person Applying for COMPLETE BASEMENT SYSTEMS INC
Permit
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Email not displaying correctly? View it in your browser.
City of Wheat Ridge
Residential Foundation Repair PERMIT - 202100275
PERMIT NO: 202100275 ISSUED: 02/17/2021
JOB ADDRESS: 3333 Simms St EXPIRES: 02/17/2022
JOB DESCRIPTION: Foundation report on north, east and south foundation with 10 push piers.
*** CONTACTS ***
OWNER (713)315-1417
BUEHLER KELLY
SUB (303)805-8751
RODNEY MARTIN
060125 COMPLETE
BASEMENT SYSTEMS
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE:
UA / Unassigned
SUBDIVISION CODE:
2403 / APPLEWOOD
VILLAGES, PROSPECT V BLOCK/LOT#:
0 /
*** FEE SUMMARY ***
ESTIMATED PROJECT VALUATION:
12,500.00
FEES
Total Valuation
0.00
Plan Review Fee
163.70
Use Tax
262.50
Permit Fee
251.85
** TOTAL **
678.05
*** COMMENTS ***
*** CONDITIONS ***
A printed copy of the permit and city stamped on-site plans must be available on-site for
the first inspection.
Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
Inspection by Wheat Ridge Building Inspector required prior to backfill. Observation letter
from Engineer to be provided to Wheat Ridge Building Inspector at Final Inspection.
1* � 4 41'
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION:
City of Wheat Ridge
Residential Foundation Repair PERMIT - 202100275
202100275
ISSUED: 02/17/2021
3333 Simms St EXPIRES: 02/17/2022
Foundation report on north, east and south foundation with 10 push piers.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any
pplicab e code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
02/17/2021
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
From: no-reolv(alci.wheatridae.m. us
To: CommDev Farm is
Subject: Online Form Submittal: Foundation Repair
Date: Friday, February 12, 2021 10:55:41 AM
Foundation Repair
This application is exclusively for FOUNDATION REPAIRS.
YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR
THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
Foundation Repair?
PROPERTY INFORMATION
Property Address 3333 Simms Street
Property Owner Name Buehler, Kelly
Property Owner Phone 713-315-1415
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email
Address
Attach City of Wheat
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
kelly@buehlr.com
Wheat Ridae Payment Form 3333 Simms Sj=
CONTRACTOR INFORMATION
Contractor Business Complete Basement Systems
Name
Wheat Ridge
Contractor's License
Number (This is a 5 or
6 digit number for the
60125
City of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-
4567)
Contractor Email
Address
720-507-2711
cbs.permits@completebasementsystems.net
Retype Contractor cbs.permits@completebasementsystems.net
Email Address
DESCRIPTION OF WORK
Location of Work North, East and South Foundation
How is repair being push piers
done? Piers, strips, etc.
# of Piers or Strips 10
Upload engineer letter
or pages on 8 1/2" x
11" only
Repair Plan Set on
11'x17" only - if
applicable
Obs Letter 3333 Simms St.odf
Project Value (contract 11900
value or cost of ALL
materials and labor)
10 x $1,250 = $12,500 Valuation
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
Person Applying for COMPLETE BASEMENT SYSTEMS INC
Permit
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Email not displaying correctly? View it in your browser.
Structural Steel:
1. Structural Steel shall be detailed, fabricated and erected in accordance with 2010 AISC Specification for Structural
Steel Buildings, and "Code of Standard Practices" 2005.
2. Structural Steel shall be confirmed to the following grades:
2.1 W & WT- Shapes: ASTM A36, A992
2.2 Plates & Angles: A36
2.3 HSS: ASTM A500 gr B
2.4 Steel Pipe: ASTM A53 gr B
3. All bolts shall conform to the ASTM A325 except anchor bolts which shall conform to ASTM A307. Bolt Size shall
be %", unless noted otherwise on the drawings.
4. All welding shall be by a certified welder in accordance with ACIS and AWS specifications and recommendation.
Structural Wood framing:
1. Except where noted otherwise, all 2" members shall be Hem -Fir No. 2 and better.
2. Except as noted otherwise, minimum nailing shall be provided as specified in Table No 2304.9.1 "Fastening
Schedule" of the IBC. All nails shall be common type, unless noted otherwise.
3. Unless noted otherwise, steel connectors such as those manufactured by Simpson Company, shall be used to join
rafters, trusses, joists, or beams to other members at flush -framed conditions. Use maximum number and size of nails
indicated in manufactures tables U.N.O. all nails holes shall be filled.
4. All multiple members shall be glued & nailed together.
5. All wood in contact with concrete or exposed to weather, shall be pressure treated Douglas Fir -Larch No. 2 or
equal.
6. Structural members shall not be cut for pipes, etc. Unless specifically noted or detailed.
Periodic surveys:
1. Periodic surveys of the supported structures should be conducted to assure project success. The Owner should be
responsible for annual surveys certifying project success. We would suggest that a baseline survey be conducted
immediately. The owner shall submit all findings and reports to the Structural Engineer.
2. If vertical movement of the piers is discovered, the piers should be re -pressured. A representative of the
Geotechnical Engineer should be present to observe the re -pressuring. A final report should be provided by the
Geotechnical Engineer after observing the re -pressuring.
Foundation Stabilization:
1. Although observed foundation damage typically does not pose an immediate health and hazard risk, delaying
mitigation will likely make future repairs more difficult and costly. Furthermore, it has been our experience that once a
structure begins moving, it will likely continue to so (unless action is taken) resulting in further settling, heaving, unsightly
cracks, doors/widows not functioning properly and possible foundation wall collapse. The extent and aggressiveness of
the foundation repairs should be carefully considered by the Owner and will depend on their tolerance for risk, the
possibility of future damage, and cost.
2. If the owner chooses to do so the foundation could be stabilized only at visibly damaged locations and areas where
movement is concentrated. Although this will address specific situations, it is possible that foundation movements will
occur elsewhere.
3. If the Owner chooses to do so, the entire foundation could be mitigated. A general system repair, although more
costly, would greatly reduce the risk of future foundation damage and movement. It is our understanding that the Owner
would not like to pursue this repair option.
Site Drainage
1. We believe that the moisture around foundation elements must be controlled for the useful life of the building.
Lack of proper drainage is often a contributing factor to foundation damage observed. It is our opinion that site drainage
around the structure must be maintained such that precipitations will quickly drain away. The use of proper slope
slabs -on -grade, moisture barriers, swales and surface/subsurface drainage systems are strongly recommended.
Extension should be attached to properly function downspouts and roof drains discharge a minimum of 10 feet away
from the structure.
Site vegetation
1. We believe that vegetation around the perimeter of structures can eventually lead to foundation movements.
Vegetation can hold moisture in soil and create excessive pressure on the foundation system. In order to reduce the
risk, bushes, shrubs and trees should be carefully removed by an experienced professional. Care should be taken to
not further disturb or damage the existing foundation system.
2. Planters and other surface features which could retain water should be eliminated and properly graded to reduce
the possibility of moisture infiltrating around the foundation. Irrigation systems and excessive moisture adjacent to
structures can introduce unwanted moisture, possibly resulting in settling and or heaving. The Owner should consider
removing irrigation systems or simply not use them.
Disclaimer:
1. In as much as the site review of an existing structure for the purpose of observing the structure conditions
requires that certain assumptions be made regarding existing conditions and because some of these assumptions may
not be verifiable without expending additional sums of money or destroying otherwise adequate or serviceable portions
of the building, the Client agrees that , except for negligence on the part of the Engineer, the Client will hold harmless,
indemnify and defend Engineer from and against any and all claims arising out of the professional services we have
provided.
LEGEND:
(E) EXISTING
(N) NEW
PUSH PIER
P.P. #X PIER #
00004)
LOAD ON PIER
HELICAL PIER
H.P. #� PIER #
(0004) � LOAD ON PIER
WALL ANCHOR City of
W.A. #x ANCHOR # Wheat Ridge
WALL BRACE Building Division
W R #x BRACE #
CARBON FIBER
C.F. #x �- CARBON FIBER #
,
POST•.�oM.P.
sMONO
#x i- POST#
C10N
()LOAD ON PIER�<v�1/2:.
REVISIONS
DATE
T
N
O
N
co R
W
H N
00 31V(
ZZ
w w O
Z
W A8
(7 JiO3F
Q
O eM
N�oJ
N
m 0 v W
fW �
a� m
U)tooiir
On Z
a�WO
ZZ 3
n
LL
v iui eN O
Z aN U
O00 O W
NJ
2WNIv(PZ
W LU
Z1!J~O Z
�OoW
WOyW~�
O �
CO
JOB NO.
2027-9706
SHEET�
S11-2
OF
3
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
2/12/2021
RE: Job# 2021-9106
3333 Simms St.
Wheat Ridge, CO 80033
As requested, a site visit and observation were performed at the property located at the address
above on 2/10/2021 at approximately 9:00 a.m. by Kelly Hoiness, PE. The purpose for the site
visit and observation was to review the structure for movement of the foundation.
The subject property is a single-family home with a finished basement located in an established
neighborhood. The building is assumed to have been built in 1968 (based on an online search of
the Jefferson County Assessors records).
The foundation is constructed of concrete and is assumed to be on spread footings. The house
appears to be constructed of wood with lap siding and partial brick veneer. The observation was
visual and limited to the exterior and the interior house. No observation was performed on the
roof structure. For purposes of this report, we assume that the house faces east.
Observations
• Cracks in the interior finishes, multiple areas on the main level. The majority of the cracks
appear to be on the east side of the house.
• Cracks in the interior finishes, multiple areas on the basement level
• The half foundation wall is slightly out of plumb on the west wall of the basement, near
the south end. There are cracks in the interior finishes in this area and it appears there
has been some slight lateral movement of the foundation wall.
• The basement interior finishes do not appear to be floated
• Cracks in the garage interior finishes
• Crack in the south foundation wall
• Crack in the west foundation wall
• Cracks in the brick veneer on the west wall
• Gaps between the brick veneer and siding on the west wall
• Stepping cracks in the brick veneer on the south wall
• Cracks in the brick veneer on the east wall
• Gaps between the brick veneer and window on the east wall
• Crack in the porch slab on the east wall
• Crack in the foundation on the east wall
• Crack in the foundation on the north wall
• Separation between the front porch slab and foundation on the east wall
1 City of
Wheat Ridge
Building Division
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
Recommendations
The cracks observed in the walls were likely caused by vertical and lateral movement of the
foundation. These movements are most likely caused by contraction and expansion of the soil
due to changing moisture content. The following is a prioritized list of recommended repairs that
should be made to stabilize the foundation:
• There appears to have been differential vertical movement of the house, with the most
prominent movement on the east side of the house. This was indicated by the cracks in
the interior finishes, the cracks in the brick veneer, and the cracks in the foundation.
Install (5) new push piers on the east wall, (1) new push pier on the north wall, (2) new
push piers on the south wall, and (2) new push piers on the south wall of the garage to
help mitigate vertical movement of this area.
• Monitor the half -wall foundation on the west side of the basement for further signs of
lateral movement. These signs may include new or worsening cracks in the foundation,
additional movement of the brick veneer on the exterior, subsiding of soil surrounding
the foundation, damage to the basement interior finishes, and/or moisture intrusion in
the basement. If further signs of lateral movement are observed, the homeowner should
contact DL Engineering for further assessment.
• Monitor the remainder of the home for further signs of vertical movement, particularly
the southwest corner of the house. These signs may include new or worsening cracks in
the interior finishes, new or worsening cracks in the foundation, floors that become more
out of level, and/or doors and windows that become difficult to operate. If further signs
of vertical movement are observed, the homeowner should contact DL Engineering for
further assessment.
• Ensure proper grading and drainage around the perimeter of the house to help prevent
excess moisture accumulation in the soil surrounding the foundation. Doing so help will
reduce soil volume fluctuations and pressure on the foundation. See best practices for
foundation maintenance for additional information.
• Patch and monitor any cracks in concrete, brick veneer, and drywall. This will give a
baseline for any new movement. If new movement is observed, contact DL Engineering
Inc. for further assessment.
• Differential vertical movement of the foundation is caused by several variables which are
beyond our ability to control or forecast. This observation only addresses the areas that
appear to be actively moving and includes recommendations to stabilize these areas. With
any vertical foundation movement, the only way to ensure complete stability is to fully
underpin the entire foundation. The extent and aggressiveness of the foundation repairs
should be carefully considered by the Owner and will depend on their tolerance for risk,
the possibility of future damage, and cost.
Best Practices for Foundation Maintenance
The following best practices are actions to maintain the service life of the foundation that can be
applied to all structures. Proper site drainage and placement of vegetation alone may not prevent
movement of a structure; however, they are prudent steps to avoid the contraction and expansion
of the soil due to changing moisture content. We share the following information, which is not
property specific, with all our clients.
2 City of
Wheat Ridge
Building Division
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
Site Drainage
• The moisture around foundation elements must be controlled for the useful life of the
building. Lack of proper drainage is often a contributing factor to foundation damage
observed. The site drainage around the structure must be maintained such that
precipitations will quickly drain away. The use of proper slope slabs -on -grade, moisture
barriers, swales, and surface/subsurface drainage systems are strongly recommended.
Extensions should be attached to properly functioning downspouts and roof drains such
that they discharge a minimum of 10 feet away from the structure.
Site Vegetation
• The vegetation around the perimeter of the structure can eventually lead to foundation
movements. Vegetation can hold moisture in soil and create excessive pressure on the
foundation system. In order to reduce the risk, bushes, shrubs, and trees should be
carefully removed by an experienced professional. Care should be taken to not further
disturb or damage the existing foundation system.
• Planters and other surface features which could retain water should be eliminated and
properly graded to reduce the possibility of moisture infiltrating around the foundation.
Figure 1: Cracks in the interior finishes, multiple areas on the main level
City of
3
Wheat Ridge
Building Division
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
Figure 2: Cracks in the interior finishes, multiple areas on the main level
Figure 3: The half foundation wall is slightly out of plumb on the west wall of the basement near the south end.
City of
4
Wheat Ridge
Building Division
•2.
G -
OL ENGINEERING, INC.
9100 W Jewell Ave
Lakewood, CO 80232
720-440-9450
www.diengineer.com
Figure 4: Crack in the south foundation wall
Figure 5: Cracks in the brick veneer on the east wall
City of
heat Ridge
Building Division
9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
Figure 6: Cracks in the brick veneer on the east wall
Figure 7., Crack in the foundation on the east wall
City of
Voeat Ridge
Building Division
—� 9100 W Jewell Ave
Lakewood, CO 80232
OL ENGINEERING, INC. 720-440-9450
www.diengineer.com
In as much as the site review of an existing structure for the purpose of observing the structure
conditions requires that certain assumptions be made regarding existing conditions and because
some of these assumptions may not be verifiable without expending additional sums of money or
destroying otherwise adequate or serviceable portions of the building, the Client agrees that,
except for negligence on the part of the Engineer, the Client will hold harmless, indemnify and
defend Engineer from and against any and all claims arising out of the professional services we
have provided.
If you should have any further questions, please feel free to contact me at (720) 440-9450 or
khoiness@dlengineer.com
° a
Sincerely,
Kelly Hoiness, PE
C)
Y N:
0054409
�SS��NA� EAG\
EXP. 10/31/21
City of
Wpeat Ridge
Building Division
INDEX:
S1-1 GENERAL NOTES
S1-2 GENERAL NOTES/LEGEND ON SITE PLANS
S2-1 FOUNDATION PLAN MUST BE ON SITE FOR INSPECTION
TYP. PUSH PIER DETAIL ALL Projects are
Subject to Field Inspections
BUILDER INFORMATION
Complete Basement Systems
11795 East 45th Ave
Denver, CO 80239
720-487-9568
General Notes:
1. Construction documents are valid for a single use at the project location and shall not be reused, copied, or
reproduced without written approval of the registered design professional in reasonable charge.
2. The contractor is responsible for the methods, means and sequence of all structural erection except when
specifically noted otherwise in the construction documents. The contractor shall provide temporary shoring and bracing,
providing adequate vertical and lateral support during erection. Shoring and bracing shall remain in place until all
permanent members are placed and all final connections are completed.
3. The contractor agrees that, in accordance with generally accepted construction practices, the contractor will be
required to assume sole and complete responsibility for job site conditions during the course of construction of the project,
including safety of all persons and property. This requirement shall be made to apply continuously and not be limited to
normal working hours. The contractor further agrees to defend, indemnify and hold owner and engineer harmless from
any and all liability, real or alleged, in connection with the performance of work on this project, exempting liability arising
from the sole negligence of engineer.
4. All existing sizes, dimensions and foundation damage shall be field verified by the contractor and owner prior to
construction. Discrepancies with the construction documents shall be reported to the structural engineer for additional
recommendations (if any).
5. Per the owner's request, the contractor shall stabilize the structure only. No attempt shall be made to lift or plumb
the foundation wall without approval for the owner and structural engineer.
Field Verification:
1. Contractor and Owner shall thoroughly inspect and survey existing structure to verify dimensions, elevations,
framing, etc. which affect the work shown on the drawings.
2. Report any variation or discrepancies to the structural engineer before work proceeding.
Design Criteria:
1. Building code: 2018 IBC, 2018 IRC with City of Wheat Ridge Amendments
2. Dead loads
2.1. Roof 20psf
2.2. Floor 12psf
2.3. Walls 10psf
3. Live loads
3.1. Residential40psf
3.2. Roof 20psf
CITY OF WHEAT RIDGE INSPECTION REQUIRED PRIOR TO BACKFILL
4. Snow loads
PROVIDE ENGINEER OBSERVATION LETTER AT FINAL INSPECTION
4.1. Roof snow load 30psf
5. Wind loads
5.1 Exposure Category C
J@y E_ oi-
DN:DC "a�-us.Kell O=L
E"IM aABfi BB
O Remo: 14m ADD nw
5.2 135 mph Ultimate Wind Speed
10" = city of
6. Seismic LoadsWheatR�dge
COMMUNITY DEVEIIWi
6.1 Seismic Design Category: B
APPROVED
6.2 Site Class: "D" per USGS
-10 .
Reviewed for Code compliance
7. Soil Bearing Capacity = 1,500 psf (assumed)
Randy Slusser 2/17/2021
Plana Examiner Date
yapdM of oen.r: WW MWWW of a pampor WPMWCfFhM specQlca[Aaee
adaonlpwwws shoo rot be a pematfas ad" aw"W of. ay wiftan m
agofthe wowstmaJmetUWVcodeaofawaraeaefaM& fk4mb
psesammp so pee owo" to r bkw a eaxd Ift ANWONa" CIFrM Aoft
rods a oM+a ardf faaaerW ur afr Map as fx cart
Foundation Design:
1. Soil conditions and types shall be verified by a Engineer during excavation.
2. All helical piles, push piers, helical anchor tiebacks, wall anchor tiebacks and connection hardware shall be
designed and installed by supplier, such that they provide the minimum allowable capacities as indicated on the
drawings. All capacities shown on the drawings are unfactored service loads and have not been reduced for live load
reductions.
3. Design of individual and continuous footings is based on an assumed maximum allowable bearing pressure of
1500 lbs. per square foot (dead load plus full live load), placed on the natural undisturbed soil, or compacted structural
fill below frost depth.
STEEL PUSH PIERS:
1. Grip Tite: Push Pier with sleeve and bearing cap and with FP3BA Retrofit Bracket
2. Install with a calibrated hydraulic ram with known pressure -to -axial -force ratio.
3.. Pier depth is dependent on depth of bearing soil adequate to provide the specified pressure resistance, therefore,
depth is not specified. Pier to be advanced until refusal is attained.
4. Installation pressure serves as empirical verifications of pier capacity, yielding an onsite load test for each pier.
Therefore, soils testing is not necessary for generating a theoretical capacity.
5. Piers shall be push piers, installed at locations shown on the plans.
6. It is assumed the each new pier will achieve penetration into bedrock or competent soil, and can be installed to
the specified capacity. Should bedrock or competent soil not be reached within reasonable depth this office should be
notified for further instructions.
7. Contractor is to maintain accurate pier depth and pressure / torque charts for each pier, showing depth and
pressure / torque at each shaft section. Charts shall be filled out in real time during installation, and maintained onsite
for engineer review during inspection. Charts shall be provided to engineer in final form upon completion.
Special Inspections
1. Special inspections shall be provided per the requirements in the UES Evaluation Report #391, Section 3.3 as
well as the requirements of the 2018 IBC Section 1705.9.
Cast -in -Place Concrete
1. All concrete design is based on the "Building Code requirements for Reinforced Concrete" (ACI 318-05/318R-05)
All structural concrete shall have a minimum 28 -day compressive strength as follows:
1.1 Footings:3,000psi
1.2 Slab on Grade: 3,500psi
1.3 Foundation walls: 3,000psi
2. Concrete shall be placed on proportioned utilizing Type 1 cement except, concrete exposed directly to soil shall
use Type 2 cement. Concrete susceptible to freeze shall be formulated or maximum frost resistance in accordance with
the ACI manual of Concrete Practice.
3. Cold weather and or hot weather placing procedures shall be provided, if conditions warrant, as recommended in
the ACI manual of Concrete practice.
Reinforcing Steel:
1. All detailing, fabrication, and placement of reinforcing steel shall be in
accordance with the ACI Manual of Concrete Practice.
2. Reinforcing bars shall conform to ASTM A615-79 and shall be
grade 60.
3. Except the drawings,
J@y E_ oi-
DN:DC "a�-us.Kell O=L
E"IM aABfi BB
O Remo: 14m ADD nw
as noted on minimum concrete protection
H sS L -n., s
for reinforcing shall be in accordance with ACI 318-05/318R-05.
c> : �� :20 :moo
4. No. 5 or larger reinforcing bars shall not be re-bent.
: Y 0054409 N
5. Welding of rebar is not permitted unless procedure is approved by
-10 .
the Structural Engineer.
ONAL
=XP. 10/31/21
REVISIONS
DATE
T
N
0
N
CO N
W r
H N
Z 31V(
J
J
W
LI A9
(9 Ji03F
H
14
Z
O e
~ oJ
N
�NVW
urn
a� m
NNO�
Z M 2
O Z
aMWO
ZZ 3
M
O
U.
V IN M O
ZaN U
a0oo�
ZJcc, d4W
�WNU0Z
WW
WG �
Z�~O Z
0OOW
W
ONW~�
o
Q0
JOB NO.
2027-9706
SHEET
SI -11
OF
3
City of Wheat Ridge
E -Res. Furnace Replacement PERMIT - 202000321
PERMIT NO: 202000321 ISSUED: 02/13/2020
JOB ADDRESS: 3333 Simms St EXPIRES: 02/12/2021
JOB DESCRIPTION: Replace 100K BTUs, 80% efficiency gas furnace in basement
*** CONTACTS ***
OWNER (713)315-1417 BUEHLER SCOTT
SUB (303)340-3400 STEPHEN JUSSEAUME 120169 DOCTOR FIX -IT
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 3,083.00
FEES
Furnace Replacement 40.00
Total Valuation 0.00
Use Tax 64.74
** TOTAL ** 104.74
*** COMMENTS ***
*** CONDITIONS ***
Both the front and back of this permit are required to be posted on the job site at all
times. If the complete permit is not present, inspections WILL NOT be performed.
Work shall comply with 2012 IRC & 2017 NEC. Smoke alarms shall comply with 2012 IRC Section
134. INTERIOR ALTERATIONS, REPAIRS, FUEL -FIRED APPLIANCE REPLACEMENTS, OR ADDITIONS, ANY OF
WHICH REQUIRE A BUILDING PERMIT, OCCURS OR WHERE ONE OR MORE ROOMS LAWFULLY USED FOR
SLEEPING PURPOSES ARE ADDED SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED
WITHIN FIFTEEN FEET OF THE ENTRANCE TO EACH ROOM LAWFULLY USED FOR SLEEPING PURPOSES
-,, M4
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION:
City ®f Wheat Ridge
E -Res. Furnace Replacement PERMIT - 202000321
202000321 ISSUED: 02/13/2020
3333 Simms St EXPIRES: 02/12/2021
Replace 100K BTUs, 80% efficiency gas furnace in basement
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees andprocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
or any ordnance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
��of��t��o
UZY13/2O20 O9�35 C0BA
CDAO22323
AHUUNT
8PSP 3333 Simms St 1O4.74
H�UUNT
PP / 8832
1O4.74
1�.74
____
KimberlyMCook aQWJ
From: no-reply@ci.wheatridge.co.us
Sent: Thursday, February 13, 2020 9:01 AM
To: CommDev Permits
Subject: Online Form Submittal: Residential Furnace/Boiler Replacement Permit Application
Categories: Kim
Residential Furnace/Boiler Replacement Permit Application
This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or
BOILER - LIKE FOR LIKE ONLY.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN
ORDER FOR THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
replacement residential
furnace or boiler like for
like?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
Property Owner Email
Address
Attach Credit Card
Authorization Form -
**DO NOT ATTACHED
RANDOM FORMS**
3333 Simms St
Scott Buehler
713-315-1417
permits@calIdoctorfixit.com
CC AUTHORIZATION FORM 3333 SIMMS ST FURNACE
APPLICATION.pdf
CONTRACTOR INFORMATION
Contractor Business DOCTOR FIX IT HEATING COOLING & ELECRIC
Name
1
Contractor's License 120169
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone 303-340-3400
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Email Address permits@calldoctorfixit.com
Retype Contractor Email permits@calldoctorfixit.com
Address
DESCRIPTION OF WORK
What type of unit is being Furnace
installed?
Number of BTUs 100
What is the efficiency 80
(%) of the unit?
Is the unit GAS or gas
ELECTRIC?
Where is the furnace or BASEMENT
boiler located (for
example, basement,
crawlspace, etc)?
Project Value (contract 3083
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
N
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Person Applying for Ofelia Rivera
Permit
Email not displaying correctly? View it in your browser.
�;M GV_SS3—)
INSPECTION RECORD
INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection
INSPECTION REQUEST LINE: (303) 234-5933
Occupanc /Y Type
19E
Inspections will not be performed unless this card is posted on the project site.
**Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.**
Inspector Must Sign ALL Spaces pertinent to this project
Foundation Inspections Date Inspector
Initials Comments
Pier
Concrete Encased Ground (CEG)
Foundation / P.E. Letter
Do Not Pour Concrete Prior To Approval Of The Above Inst
Underground/Slab Inspections Date Inspector
Initials I Comments
Electrical
Sewer Service
Plumbing
Do Not Cover Undprnrniind nr Rol.,...n.,_ci�M 1n1. 1, n_:__ T_ w
s
Rough Inspections
- -
Date
----- ..--......gym
Inspector
Initials
. •, ^NM—val yl i nv moove inspections
Comments
Wall Sheathing
Mid -Roof
Lath / Wall Tie
Rough Electric "
Rough Plumbing/Gas Line
Rough Mechanical
Rough Framing
Rough Grading
Insulation
Drywall Screw/ Nail
Final Inspections
Date
Inspector
Initials
Comments
Landscaping & Parking / Planning Dept.
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
ROW & Drainage / Public Works Dept.
Floodplain Inspection (if applicable)
Fire Inspection / Fire Protection Dist.
Final Electrical
Final Plumbing
Final Mechanical
Roof
Final Window/Doors
Final Building
NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate
of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy.
'For low voltage Dermits - PIPaSP ha curs that rni ink in _,.♦in.
.+ ----r--- -^•-- ��•••1+.�.�+�+ ��.+1.� u�c � lu vwuwL aiiu eieclnGal iow voltage
by the Building Division.
Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued
Protect This Card From The Weather
s City of Wheat Ridge
Residential Roofing PERMIT - 201703537
'ERMIT NO: 201703537 ISSUED: 07/10/2017
OB ADDRESS: 3333 Simms ST EXPIRES: 07/10/2018
OB DESCRIPTION: Residential Re -roof to install asphalt shingles - 21.44 sq.
** CONTACTS ***
)WNER (303)202-3900 BROWNE RICHARD J
;UB (303)778-8010 Scott Lawerance 019349 AquaDuct Roof & Gutters
** PARCEL INFO ***
;ONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
E** FEE SUMMARY *** ESTIMATED PROJECT VALUATI(5N: 7,311.00
FEES
Dotal Valuation 0.00
Jse Tax 153.53
Permit Fee 172.60
** TOTAL ** 326.13
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior. to Final
approval. Installation of roof sheathing lnew or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are
required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and
water shield is required. Eave and rake metal is required. A ladder_ extending 3 feet above
the roof eave and secured in place is required to be provided for all roof inspections.
Roof ventilation is required to comply with applicable codes and/or manufacturer
instailation instructions, whichever is more stringent. In order to pass a final inspection
of elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer technical representative stating that "the application of the roof at (project
address) has been applied in accordance with the installation instruction for (roof
material brand name) roof covering" is required to be on site at the time of final
inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
A City of Wheat Ridge
Residential Roofing PERMIT - 201703537
PERMIT NO: 201703537 ISSUED: 07/10/2017
JOB ADDRESS: 3333 Simms ST EXPIRES: 07/10/2018
JOB DESCRIPTION: Residential Re -roof to install asphalt shingles - 21.44 sq.
*** CONTACTS ***
OWNER (303)202-3900 BROWNE RICHARD J
SUB (303)778-8010 Scott Lawerance 019349 AquaDuct Roof & Gutters
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,311.00
FEES
Total Valuation 0.00 rw 1%6
Use Tax 153.53
Permit Fee 172.60
** TOTAL ** 326.13
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require ori the entire roof when spaced
or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are
required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and
water shield is required. Eave and rake metal is required. A ladder extending 3 feet above
the roof eave and secured in place is required to be provided for all roof inspections.
Roof ventilation is required to comply with applicable codes and/or manufacturer
installation instructions, whichever is more stringent. In order to pass a final inspection
of elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer technical representative stating that "the application of the roof at (project
address) has been applied in accordance with the installation instruction for (roof
material brand name) roof covering" is required to be on site at the time of final
inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
City of Wheat Ridge
a
Residential Roofing PERMIT - 201703537
PERMIT NO: 201703537 ISSUED: 07/10/2017
JOB ADDRESS: 3333 Simms ST EXPIRES: 07/10/2018
JOB DESCRIPTION: Residential Re—roof to install asphalt shingles — 21.44 sq.
11 by m signature,° do hereby attest that the work to be performed shall comply with all accompanying= approved plans and specifications,
applicable building codes, and•�all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the le al owner.of the pr3eiTy and am authorized to obtain this permit and perform the work described and approved in conjunction with
this per <'I fur `"r att at I am leggally authorized to include all entities named within this document as parties to the work to be
perfofine an k perforated is disclosed in this document and/or its' accompanying approved plans and specifications.
Si d`ture dr i"OWNER or CONTRA'CTOR.. Circle one) Date
1. This permit was issued based on the inibnnation provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans
and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing. and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division,
6. The issua ranting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicabl�'co e r any ordmaus�.er regVlaticin of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us
between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line.
Dan Schultz Z0 [ 70553
From:
no-reply@ci.wheatridge.co.us
Sent:
Monday, June 26, 2017 1:12 PM
To:
Permits CommDev
Subject:
Online Form Submittal: Residential Roofing Permit Application
Categories:
Dane
Residential Roofing Permit Application
n
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT
IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME
S
WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your
contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit. Permits are currently being
processed within 5 business days, subject to change based on volume.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address 3333 Simms Street
Property Owner Name Rick and Jan Browne
Property Owner Phone 303-202-3900
Number
Property Owner Email
thisisrick@aol.com
Address
Do you have a signed
Yes
contract to reroof this
property?
It will need to be
provided at the time of
permit pick-up.
CONTRACTOR INFORMATION
Contractor Name
AquaDcut Roof and Gutters
Contractor's License
01-9349
Number (for the City of
Wheat Ridge)
Contractor Phone
303-778-7663
Number
Contractor Email Address
quotes@aquaductgutters.com
Retype Contractor Email
quotes@aquaductgutters.com
Address
DESCRIPTION OF WORK
Are you re -decking the
No
roof?
Description of Roofing
Replace only 30 year dimensional shingles (tie into existing
Material
modified roofing on patio cover)
Select Type of Material:
Asphalt
If "Other" is selected
Field not completed.
above, describe here:
How many squares of the
21.44
material selected above?
Does any portion of the
f.
No
property include a flat
/
roof?
If yes, how many squares
Field not completed.
on the flat roof?
2
TOTAL SQUARES of all 21.44/'
roofing material for this
proj ect
Provide additional detail
here on the description of
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
7311.0
House
Project Value (contract
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant Scott Lawrence
Email not displaying correctly? View it in your browser.
3
Bid generated for Rick and Jan Browne
Company Receipt Page
Owens Corning
TruDefinition® Duration LLT
Terra Cotta
Owens Corning
TruDefinition® Duration LLT
Total Cost : $ 9,984.16 .
' 130 mph wind resistance warranty
' UL 790, UL Class A Fire Rating, Class F anf H
Wind Rating
' Integrated polymeric backing material
' Limited Lifetime warranty, vibrant color blends
' SureNail® and WeatherGuard& Technology
Terra Cotta
Authorized Signature
Date
Aqua Duct Roof & Gutters
Custom bid generated for
Rick and Jan Browne
3333 Simms Street
Wheat Ridge, Colorado 80033
303-202-3900
Job site address
3333 Simms Street
Wheat Ridge, Colorado 80033
303-202-3900
Product Choice : ILA
Color Choice: ✓4
Customer Signatui J
Date . 7- Z,� -17
A i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: _AAS,
Job Address: 5 -3 3
Permit Number:
❑ No one available for inspection: Time d KM/PM
Re -Inspection required: Yes �Np
When corrections have been made, call for re -inspection at 303-234-
Date:- "P ! Inspector:
DO NOT REMOVE THIS NOTICE
A i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: k`6 F
Job Address: 53:35 S k
Permit Number: ;2C11> 6) $ c• 3 9
❑ No one available for inspection: Time D!-' r` �jpm
Re -Inspection required: Yes 66)
When corrections have been made, call for re -inspection at 303-234-5933
7
r
Date: `f / �� r, Inspector: 1 , - v to l
DO NOT REMOVE THIS NOTICE
INSPECTION RECORD OccupancyRVpe
'INSPECTION LINE: (303) 234 -5933
Inspections will not be made unless this card is posted on the building site
Call by 3:00 PM to receive inspection the following business day.
INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB
FOUNDATION INSPECTIONS
DATE
INSPECTOR
INITIALS
COMMENTS:
Footings /Caissons
Stemwall / (CEG) Concrete
Encased Ground
Reinforcing or Monolithic
Weatherproof / French Drain
Sewer Service Lines
Water Service Lines
CONCRETE SLAB FLOOR
Electrical (Underground)
Plumbing (Underground)
Heating (Underground)
ROUGHS
Lath / Wall tie
Mid -Roof
Electr Service
Rough Electric
Rough Plumbing
Gas Piping
Rough Mechanical
HAS BEEN SIGNED
ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING
Framing
Insulation
Drywall Screw
FINALS
Electrical
Plumbing
Mechanical
Roof
Building Final 1
Fire Department
R.O.W H Drainage INSPECTIONS FOR PLANNING S ZONING, FIRE AND PUBLICE WORKS
Parking $ Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS.
` * NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A
CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION
OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY.
OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED
PROTECT THIS CARD FROM THE WEATHER
i CITY OF WHEAT RIDGE
Building Inspection Division
]~;Ir(303) (303) 234-5933 Inspection line
235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
r'
Job Address: ? F 5..-
Permit Number:
J e°`
r;
❑ No one available for inspection: Time AM/PM
Re-Inspection required: Yes No
When corrections have been made, call for re-inspection at 303-234-5933
Date: O Q,G'r Inspector: _11 c .
DO NOT REMOVE THIS NOTICE
CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234 -5933 Inspection line
J (303) 235 -2855 Office ' (303) 235 -2857 Fax
INSPECTION NOTICE
Inspection Type:
Job Address /Permit Number: '7r/
El No one available for inspection: Time s!' AM/PM i
Re- Inspection required: Yes ro f
When corrections have been made, call -for re- inspection at 303;234 -5933
{) A IA
Date: Inspector:
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge
/ Residential Roofing PERMIT - 091874
PERMIT NO: 091874 'ISSUED: ..09/01/2009
JOB ADDRESS: 3333-SIMMS ST- EXPIRES: 02/28/2010
DESCRIPTION: Reroof 26.67 sqs
***-.CONTACTS
owner 303/202-3900 'Browne
sub 303/778-8010 Scott Lawerance 01-9349 AquaDuct Roof & Gutters
PARCEL. INFO
ZONE CODE: UA USE: UA
SUBDIVISION:' 0659 '.BLOCK/LOT#: 0/
FEE SUMMARY ESTIMATED PROJECT VALUATION: 9,438..00
FEES
Permit Fee 235.70
Total Valuation .00 [y n0'Lel
Use ;Tax 169.86 en
**.TOTAL 405.58 : r...
Conditions: -
6 nail installation& mid-roof inspection required. Board sheathing spaced more
than a 1/2 of an inch apart requires plywood overlay on entire roof. Ice and
water shield required from save edge to 2' inside' exterior walls.F
Subject to field inspections.
I hereby certify tha he setback distances proposed by this permit application are accurate, and do not violate applicable
ordinances, rules o lations of the City.of `Wheat: Ridge or covenants,.: easements or restrictions of record; that all
measurements shown, allegations made are accurate;. that I have read and agree to abide by all conditions :printed on this
application: an ('J ssume ful respo ibility for.. compliance with the Wheat Ridge Building Code. (L.B.C) and all other.
applicable Wh 'n c ,`fo work under this permit. Plans subject to field inspection.
Signature d co or owne date
1. This permit was issued in accordance with the.. provisions set forth.. in your application and is subject to the laws of the
lState of Colorado and'to. the Zoning Regulations and Building Codes of Wheat Ridge,.. Colorado or any other. applicable
ordinances of the City..;'
2. This permit: shall expire 180 days :from the issue date. Requests for an extension must be received. prior to expiration
date. An extension may be granted at the discretion of the Building Official.
3. If this permit expires, a new permit may be acquired for a fee of'one-half the amount normally required, provided no
changes have been or. will be made. in the original plans and specifications and any suspension or. abandonment has not
exceeded one (1) year.,. If changes have been or if suspension or abandonment: exceeds. one (1) year, full fees: shall
be. paid for. a new permit.
4. No work of any manner: shall be done that will change the natural flow of water causing a drainage. problem.
5. Contractor shall notify.: the Building Inspector twenty.-,four (24) hours in advance for all inspections and shall receive
written approval on inspection card before proceeding with successive phases of the job.
6. The issuance. of a permit. or the approval of .'drawings and specifications shall not be construed to be a permit for, nor
an approval of,{ a rolation of the provisions of the building codes or any other ordinance, law, rule or regulation.
All. plan v4iejy subject to field inspections.
Signature of hie. Building :Official date
INSPECTI N REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855
REQUESTS MUST BE MADE BY 3PM ANY'-BUSINESS :DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
~oFW"~TRa City of Wheat Ridge Building Division
m 7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
~ocorxra° Inspection Line: 303-234-5933
-33J
Property Owner (please print):
Building Permit Application
gi m' 'J'-~'t'
Date: U a j bc'j
Plan A
Permit C l p-4
Phone: 3
Mailing Address: (if different than property address)
Address:
Sub Contrac#ors
Electrical City License
Company:
Plumbing City License Mechanical City License
Company Company:
Exp. Date: Exp. Date: Exp. Date:
Approval: Approval: Approval:
Use of space (description): Construction Value: $
Description -o work' (as calculated per the Buildinq Valuation Data sheet)
4 Plan Review (due at time of submittal): $
-7 ~
Sq. Ft./L.Ft added: Squares c 3BTU's Gallons Amps
c~
11
Contractor License Phone: CJ o3) 77p - 7~(, 3
, DEPARTMENT OF PLANNING AND DEVELOPMENT
BUILDING INSPECTION LINE - 303-234-5933
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Building Permit Number
Date
10946
8/1 /2000
Property Owner :
Property Address : 3333 SIMMS ST
Contractor License No. : 19349
Company : A-1 Home Remodelers
Phone :
Phone: 7788010
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurete,
and do not violate applicable ordinances, rules or regulaiions of the City of Wheat Ridge or
covenants, easements or restridions of record; thaR'all measuremenis shown, and allegations
made are accurate; that I have read and agree to qbid by all conditions printed on this
application, and that I assume full responsibdiry foi pliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Whe~[ Ridge, , inances, for work under this permit.
(OWNER)(CONTRACTOR)
Description : RESIDE (VINYL) 20 SQUARES
Construction Value :
$10,000.00
Permit Fee :
$181.25
Plan Review Fee :
$0.00
Use Tax :
$150.00
Total:
$331.25
Use:
Electrical License No :
Company :
Expiration Date :
Approval:
Plumbing License No :
Company :
Expiration Date :
Approval :
Mechanical License No :
Company:
Expiration Date :
Approvai:
(7) accordance with the provisions set forth in yopur applicatlon and is subject lo the laws of the State of Colo2do and lo the Zoning
Code of Whea[ Ridpe, Colorado or any other applicable orUinances of the Ciy.
(2) (A) the work authoAZeO is not commencetl within sixry (BO) tlays M1om issue date or (8) Ne builtling authorizetl is suspended or
f 120 tlays.
(3) :w pertnit may be acquired for a fee of onahalf the amount nomaly required, provitletl no changes have been or will be made in the
cations entl arry suspension or abantlonment has not exceetled one (1) year. If changes are made or if suspension or abantlonment
fees shall be peid for a new pertnit.
(4) hall be tlone that will change the natural flow of water causing a tlreinage problem.
(5) e Builtling Inscector twenty-four (24) hours in advance tor all inspections antl shall receive written approval on inspEC6on card before
Ive pheseBOtMe1'ob.
(6) or the approval of drawin8s and specifications shall not be construetl to he a permtt for, nor an approval of, any violatlon of the provisions
ny other ordinance, law, rule or regulation.
Chief Building Inspector
DEPARTMENT OF PLANNING AND DEVELOPMENT
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHE T
Prooerty Owner :
°roperty Address :
Contractor License No. :
Company:
OWNER/CONTRACTOR SIGNATURE
/ I~3333 J :
/93`~~
Building Permit NumC=r :
Da,e :
I hereby certify that the setback distances DroposeC by this pertnit ;
and tlo not violaro applica6le ordinances, rvles o ulaGOns ot the
covenants. easements or restnaivns of rccortl: t alt mnaureme
matle are accurate: that I have reatl antl agrc t abide by all con i
application, and ihat 1 assume NII rcsponsibil' r~ pWncs f h
CoCe (U.B.C.) and all other appliable 1/Vh@a idgpyqM inqq , or
(OWNER)(CONTRACTOR)
DeseriPtion :
JG AND AGREEMENT
pplitltlon ifG iCCtlntG,
Ciry of 4Vheat Ridge or
as snown, and alleqations
ionS pnntetl On Mii
Ne Wheat RiEge Building
wark unaer tnis pertnit.
% DATE'7f ` I "CTIS
W ~
Construction Value : I~p
Permit Fee :
Use Tax :
Phone:
PhOne : 3U3 77U' ~d ~U
Total :
use : J U~
BUILDING DEPARTMENT USE ONLY
Approval:
Zoning :
w_ n m
Approval:
CafflMW
.
l$7
Approval:
Occupancy : Walls
Roof
Sq. Ft. :
Stories : ResidenGal Units :
Electncal License No : Plumbing License No : Mechanical License No :
Company: Company: Company:
Expiration Date : Expiration Date : Expiretion Date :
Approval : Approval :
Approval:
(1) Tiw Permrt ras qws0 m mCmtObe Mtl~
pewiaM M n TDOK aOYkoEOn an! s i b Ih
RC9u11 o M IO
W~Ct laws ot 1M Stab ef CdoraOe aM m Ity •
Gpy ~1tl Buqnq COOe af N~MRlti 1NOp~, CalaraOD a wry atlw ipptiODN aEnafl~ ot iM Clly.
(1) Tnf CemMtltNtl eap~ R(A) V1f MOIk iutlql6l0 u n0I ~IRAnOM MNUn l~IY (60) Eiyf hom iOw Cmte Ot (B) tl1eDYiltlinq autl10RR0 UfuaPet7 Of
abanarneC 1ar a oaioa ol 120 Eays ~~p
b .
(7) u.Inu Pertnrt aaPaea. i nw p~nnt ^y~' bs w~ne far a M a1on*.IWf vN anwnt nomrW ~7msE. pwiaC ro ehsnpes tuN Man a wiu Ce m~ae n tlr
°"9""' "b'p"o~s w+er t~prebn ar aEr+mnmam ios na m~aama av (t)rw.
n a~nyes a~ mwa a rt swaansen or a~eom'rnt
e~ aw (t) Yrr. NY Ieo anul W Pw far a nw p,mN.
(a) No worK ot ury mannr aMaY 0~ Caie YW W~arq~ tlr natlual Ilow ef ~ralr~f~p ~ y~ym@ppp~,
(5) Cp~aoCmNa ~y~u 9~ ~~y~ y~b,bv Rq ~oues n advann far W wPa~tlers aM W6 naive r~n appw+~ m wpsbon e~d eebw
(6)
oe Tht tne wt ew~ af i pmmlalM ~OpoRf 0f ~awnpa iM ap~c~pqqalW nol0e OCnatrYeC b 0g a
uiquq mGes a mY mwr admnw. w. nr Q nme.ee.~ Pe lor, nor m apprwal oe, arry vldaean ar eu wowaian
A RIDGE, CO 80215 AppL1CATIo N
SIC
Chiet Buiiding Inspeetor
`4DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 10850
BUILDING INSPECTION LINE - 303-234-5933
CITY OF WHEAT RIDGE Date : 7/17/2000
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Property Owner :
Property Address : 3333 SIMMS ST Phone : 237-2171
Contractor License No. : 20729
Company : SKYLIGHT SPECIALIST INC. Phone : 761-2200
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certiry that the setback distances proposed by this permit application are accurate,
and do not violate appliwble ordinances, rules or regulations of the Ciry of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable eat Rid e ordinancesf work under this permit.
(OWNER)(CONTRACTOR) SIGNED V DATE_7&
Description : REPLACE PORCH ROOF
Construction Value : $3,337.00
Permit Fee : $97•25
Plan Review Fee : $0.00
Use Tax : $50.06
Total: $147.30
Use:
Electricai License No :
Company :
Expiration Date :
Approval:
Plumbing License No :
Company:
Expiration Date :
Approval:
Mechanical License No :
Company :
Expiration Date :
Approval:
(1) This pertnit was issued in accorUance wfth the provisions set foRh in yopur appliwUOn and is subject lo the laws of the State of Coloredo and to the Zoning
Regulations arW Builtlinp Code of Wheat Ridpe, Colorado or any other applicable ortlinances M the Ciry.
(2) This permit shall ezpire if (A) the woilc authorized is not commencetl within sixry (80) tlays from issue tlate or (B) the builGing authonzed is suspende0 or
abandoned for a penod W 120 tlays.
(3) If this permk expires, a nev+ permit may be acquiretl for a fee of one-half the amount normally requireQ provided no changes have been or will be matle in the
original plans antl specifcatbns and any suspension or abandonment has not ezceeded one (1) year. If changes are made or if suspension or abantlonment
exceeds one (1) year, full fees shall be paid for a new permi4
(4) No woAc of any manner shall De done that will change the naturel Ilow of water causing a draina9e problem.
(5) Contraclor shall notiry the Builtling Inspector twenry-four (24) hours in atlvance for all inspections antl shall receive wntten approval on inspection cartl before
roceediing with suaessive phases o( the ~ob.
(e) pThe issuance of a pertnit or the approval o~tlrawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions
of the building codes or any ofher ordinance, law, rule or requlaUon.
Chief Building Inspector
EPARTMENT OF PL/ANNING AND DEVELOPMENT
P r
BUILDING INSPECTION LINE - 303-234-5933
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
QA-
c~
Contractor License No. : 2~? Z 1
Property Address: ~J2✓73 L✓lµ^``r>
Buiiding Permit Number :
Date :
Phone : Z 3-? --2- l-) I
CompanY : S-" l,i U fl T ~-TR.C._ ,(/J C_ , Phone :-7(o 1- 2. -L. l7 C
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurete,
and do not violate applicable ordinances, rules or regulations of the Ciry of Wheat Ridge or
covenants, easements or restridions of record; that all measurements shown, and allegations
made are accurete; that I have read and agree to abide by all wnditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicabl eat Rid~ rdinances, jP or work under this permd.
~ ~
(OWNER)(CONTRACTOR) SIGNED V DATE 4G OO
Description: ZLPL'rN-C- %k- ii,Re-- kq. Z.o~q J-
Construction Value :
Permit Fee :
Use Tax : 3,33? 3~3
Total :
Use:
BUILDING DEPARTMENT USE ONLY
SIC : Sq. Ft. :
Emma= Approval:
Zoning :
BR[
Approval:
s
Approval :
Occupancy : Walls : Roof : Stories : Residential Units :
Electrical License No :
Company :
Expiration Date :
Approval:
Plumbing License No :
Company :
Expiration Date :
Approvai:
Mechanical License No :
Company:
Expiration Date :
Approval :
(1) This pertnit was issuetl in accortlance with the provisions set foM in yopur appliwtlon antl is suhject to the laws of the State o! Colorado and to the:Zoning
Regulations antl Builtling Cotle W Wheat Ritlge, Coloretlo or any oMer applipble ordinances of the Ciry.
(2) This pertnit shall expire it (A) the work auVronzetl is not commenced wiNin sixty (80) Eays from issue tlate or (e) the builtling authorized is suspentled or
abandoneA for a penotl of 120 tlays.
(3) If this Dermk expires, a new pertnit may be acquireC for a fea of one-half the amount normally required provided no changes have been or will be made in the
onginal plans anE speciflcaUOns antl any sus0ension or abantlonment has not exceetletl one (1) year. If changes are matle or if suspension or abantlonmenl
exceeds one (i) year, /ull tees shall be paitl kr a new pertnil
(4) No work af any manner shall be tlona that will change the natu2l fiow of water wusinq a drainaga pmblem. (5) Contraclor shall no6y the Building Inspeclor lwenty-kur (24) hours in atlvance kr all mspeclions antl shall receive wntten approval on inspedion wrtl before
(6) The issuance of a pertnit ar
of the builAing co0e5 ar any
Property Owner : 'J cp-) a-
and specifiwtions shall rqt be construed to De a pertnit for, nor an approval of, any violation of the provisions
~orregulaaon. .
Chief Building Inspector
DFPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 95(1229)
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE Date :6/16/95
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Property Owner : HEPPE DAVID L
Property Address : 3333 SIMMS ST
Contractor License No. :
Company :
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certiy lhat the setback distances proposed by this permit application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibiliN for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Wheat I~idge ordinances, for work under this permil.
(OWNER)(CONTRACTOR) SIGNED DATE
Description : REROOF
Phone: 237-2171
Phone:
Construction Value :
$1,000.00
Permit Fee :
$25.00
Plan Review Fee :
$0.00
Use Tax :
$25.00
Total:
$50.00
Electrical License No : Plumbing License No : Mechanical License No :
Company: Company: Company:
Expiration Date : Expiration Date : Expiration Date :
Approval: Approval: Approval:
M m
(7) This permit was issued in aaortlance with the provisions set foM in yopur application and is sub'ect to the laws of ihe Slate of Colo2tlo and to the Zoning
Regulalions antl Building Code of VMeat Ridge, Colorado or any other applicable ortlinances of e City(2) This permit shall expire if (A) the work authorize0 is not commenced within sixty (60) days from issue date or (B) the builtling authorized is suspentled or
abanGOnetl for a period ot 120 tlays.
(3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provitled no changes have been or will be made in Ihe
original plans antl specifwtions antl any suspension or abandonmenl has not exceetletl one (1) year. If changes are matle or it suspension or abantlonment
exceeds one (1) year, full fees shall be paitl For a new permit.
(4) No work ot any manner shall be tlone that will change the naturel flow of water wusing a dreinage problem.
(5) Contractor shall no6fy the Builtling Inspector hvenry-four (24) hours in atlvance tor all inspections antl shall receive written approval on inspection card betore
proceediing with successive phases oFthe 7ob.
(6) The issuance of a permit or the approval of drewings and specifwtions shall not Ee construetl lo De a permit for, nor an approval ot, any violation otthe provisions
of Ne building wtles or any other ortlinance, law, rule or regulation.
Chief Building Inspector
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION
r~_~
DEPARTMENT OF PLANNING AND DEVELOPMENT
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Date :
Property Owner : E)C)-VC
Property Address : ~333 S,
Contractor License No. :
Company : F4OI'?er1c✓1W
Phone
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restnctions of record; that all measurements shown, antl allegations
made are accurate; that I have read and ayree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Wheat Ridge ordi nces, for work under this per it.
(OWNER)(CONTR4CTOR) SIGNED ~ DATE
, 1 1 C
Description : 7(-w o* Ve S , A ?rl'
l
DEPARTMENT USE ONLY
i
Approval:
Zoning :
Approval:
Psx~r~au~
Approval :
Occupancy : Walls : Roof : Stories
Construction Value : 1U00,47; j
Permit Fee : ~-rj . ()O
Use Tax : QS ,w
Residential Units :
Electrical License No :
Company :
Expiration Date :
Approval :
_j ns~~~,~ z1
P .
Plumbing License No :
Company :
Expiration Date :
Approval :
j i PIil~irmm!itbU t '..'I
Mechanical License No :
Company :
Expiration Date :
Approval:
(1) This permrt was issuetl in accordance with the provisions set Forth in yopur application antl is subject to the laws of [he State of Coloratlo antl ro Ne Zoning
Regulations and Builtling Code ot VJheat Ritlge, Coloratlo or any other applicable oidinances of the City.
(2) This permit shall expire it (A) the work authonzed is not wmmenced within sixry (60) days (rom issue date or (B) Ihe building authorizetl is suspended or
abandoned for a penod of 120 tlays.
(3) If this pertnit expires, a new permit may he acquired for a fee of ane-half the amount normally required, provided no chan9es have been or will be made in the
original plans antl specifications antl any suspension or abandonment has not exceetled one (1) year. It changes are maUe or if suspension or aDanAOnmant
exceeds one (1) year, (ull (ees shall bE paid for a new permit.
(4) Nb work of any manner shall be tlone that wiil change Ihe natural flow of water causing a dreinage problem.
(5) Contractor shall notiry the Builtling Inspector hvenry-four (24) hours in atlvance for all inspections and shall receive written approval on inspecUOn carU before
proceetliing with successive phases of the job.
(6) The issuance of a permit or lhe aDProval of drawings antl specificalions shall nol be consVUetl to be a permit for, nor an approval of, any viola6on of the provisions
of Ihe building codes or any other ortlinance, law, rule or regulation.
Chief Building Inspector
Sr' W!~~tl n~KPL 601 Phone : a3 ! / /
J
For Mayor
Building Permit Number :
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION