Loading...
HomeMy WebLinkAbout3363 Simms StreetCity of Wheat Ridge Homeowner Addition PERMIT - 202000835 PERMIT NO: 202000835 ISSUED: 05/28/2020 JOB ADDRESS: 3363 Simms St EXPIRES: 05/28/2021 JOB DESCRIPTION: Construct gable patio cover on top of existing garage; 20 ft x 20ft walk out patio on top of garage - 400 sq ft total *** CONTACTS *** OWNER (303)237-4170 SKWAREK LESZEK *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,510.00 FEES Total Valuation 0.00 Plan Review Fee 91.59 Use Tax 115.71 Permit Fee 140.90 ** TOTAL ** 348.20 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. City of Wheat Ridge ..r Homeowner Addition PERMIT - 202000835 PERMIT NO: 202000835 ISSUED: 05/28/2020 JOB ADDRESS: 3363 Simms St EXPIRES: 05/28/2021 JOB DESCRIPTION: Construct gable patio cover on top of existing garage; 20 ft x 20ft walk out patio on top of garage - 400 sq ft total I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any agpj cable code of py ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of'Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. C�ty J. Wheot Kidge V�/28/2O20 C." C08B �A L;leoa� C0��9� AKOUNT �P3P 3363 Simms St 3O8.87 APnL/PERMIT NU/ 2O2O8OD35 �n / 9646 3U8.87 AUTH COO�: 75?35Y6J TOrAL JO8.87 From: no-renlv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Addition to Existing Building Date: Tuesday, May 5, 2020 10:24:32 AM Addition to Existing Building Step 1 THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Items Needed to Submit for an Addition Is this Residential or Residential Commercial? Step 3 PROPERTY INFORMATION Property Address 3363 simms st Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Lester Skwarek 11#18161-18611 RUN lejkj555@gmail.com Electronic Payment Form - Rey sed 5-1-20 Fillable 202005011620013849 encrypted .Ddf APPLICANT INFORMATION Applicant Name What is your role in the project? Contact Phone Number (enter WITH dashes, eg 303-123-4567) Lester Skwarek Property Owner 7205891962 Contact Email Address for Plan Review Comments Retype Contact Email Address DESCRIPTION OF WORK Detailed Scope of Work - Provide use of addition (i.e. master bedroom with master bathroom); Indicate mechanical, electrical, plumbing scopes Location of Work Square Footage of Addition Asbestos Report Engineering Letters, Energy Calcs and Other Letter Size Attachments lejkj555@gmail.com lejkj555@gmail.com Gable Patio cover on top of existing garage. 20ft by 20ft walk out patio on top of garage On top of garage that is a flat roof. 380 Field not completed. IMG 0686.JPG Construction Plans IMG 0685.JPG scanned on 11'x17" or larger Provide Passcode for Field not completed. Plans if locked Project Value (contract 1500 for materials and labor is done by homeowner value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for leszekskwarek Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. reside at the project property, or intend to reside at the property for a penoa 01 one yea, e.�= completion of the project, and am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, list them on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property. Property must be in individuals' name, not a company. Property Owner(s): L P ate Project Prop( Project Type: Notarized signature of Applicant State of Colorado } County ofJe } ss The foregoing instrument was acknowledged by e_6 ,er 5d'A) rey— me this day of 201Q by TR Y HOWARD NOTARY PUBLIC STATE OF COLORADO NOTARY ID 20184007604 MY gem .. u ■tPIREs 0215@ 022 tary Pu 'C My Commission Expires _LJLiJ2rJZL ON SITE PLANS MUST BE ON SITE FOR INSPECTION ALL Projects are Subject to Field Inspections May 4, 2020 City of Wheat Ridge Building Department 7500 W. 291^ Ave. 2nd Floor Wheat Ridge, CO 80033 Re: Skwarek Residence, 3363 Simms St, Wheat Ridge, CO To Whom it May Concern: I, Ronald Manske, am a licensed professional engineer in the state of Colorado (License No. 38655) practicing in structural engineering. This letter is to document the structural review I performed on the above residence on Monday, April 13, 2020 and provide recommendations. The Homeowner, Lester Skwarek, engaged me to review the structural feasibility of his home to support a new covering over the rooftop patio above the garage of the home. Mr. Skwarek showed me a conceptual drawing of an open structure with a gabled roof supported by timber posts, framed out of wood. The new covering is to be approximately 20 FT long north to south by 20 FT wide east to west. The ridge runs in the north to south direction and the structure is to be framed with wood framing. The west side of the structure will bear on existing walls and the east side will bear over the garage roof. I reviewed the garage roof joists, unsheathed bearing walls, and perimeter of the home. The roof joists are 2x10 dimensional lumber spaced at 12" on center, spanning 19'-9". Walls are framed with 2x4 studs framed at 16" on center. Mr. Skwarek reported that the home was built in 1963. The structure is in good condition for its age. I did not observe evidence of structural deficiencies or significant deterioration or settlement. It is my professional opinion that the bearing walls and foundations are capable of supporting the additional weight of the covering. However, the roof joist supporting the east posts will need to be supplemented with additional framing to bear the load on the east side of the covering. The posts on the east side of the covering should be supported by a total of three (3) 9.25"x1.75" 1.9E or 2.0E Laminated Veneer Lumber (LVL) beams fastened together with 2 rows of screws at 24" on center (or as recommended by the manufacturer), with screws staggered between rows. Where the LVL assembly bears on existing walls, the adjacent wall studs should be supplemented with two additional 2x4 studs or place a 4x4 post inside the existing wall beneath the beam assembly. The scope of this letter is limited to my review of the existing home for capacity to support the new covering. Please do not hesitate to contact me if you have any questions. Sincerely, Ronald F. Manske, PE CO License No. 38655 (970) 556-3312 ron@manskes.net City of Wheat Ridge Building Division ANG 2. ON SITE PLANS �( Grab j`n MUST BE ON SITE F I SIrrrP---EE------C������,,,riON 20' / 20' P�` ii o l/ablie, C 0VQ V- -- i^hP'oiect Subject to Field Inspe ions F+ Of A&E �-O p C Provide 36 inch minimum in height guard rail complying with 2012 IRC section 312 10 G, (9 ft?- t New pQ.4k o Covef- qoo sf:- Reviewed for Zoning Compliance by the , r. City of Wheat Ridge Planning Division APPROVED YVI BY: � DATE: May 15, 2020 COMMENTS: Approved with conditions Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. City of �Wheat E 'd Y coge APPROVED Reviewed for Code Comolianee Randy Slusser 5/18/2020 Plans Examiner Date VaN ky of m mlt: fie isspaeee c/o pewee w wwomrrf of orns spec4kotowv one wmputanons shoe not be a prrm/e/o, w an opprwbl o/, ww nofobon m wry of me provlsAom o/ the burkNot rode or of oty My wdhsooso. Permhs pre um ng to VW outh" to Mwom or m 1 the promiom of ere away coda orotha ordrpppas of ft Oty shoe wt be woad 4 11 FOR OFFICE USE ONLY i Building Permit Application Complete all information on BOTH sides of this form t�, F�.��.F .�� ,,.,..�....,......,..., t Btu a G allons Amps Squares Other Buildin (Contract value or the cost of &materials and labor included in the Infire pro*ect) Division Valuatio Property Owner Property Address Contractor Llcense No. Campany Plumbing License No : Company: OVdNEWCONTRAGTOR SI6NATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $1 •0 mas tne aea.dc dhances Pmposea by mb pennnmpncatwn are a«airats, ulatlons of the oity oi 1Nheat Rldge or ne ortlinanr ~es ruba w re Pertnit Fee : $33.00 . , p reatrktlons of iatwrd; that all meeauromeMs ahorm, and adapatlonn PIBn R8Vi9YV Fee : $0.00 tate; tlret 1 haw reed erM pree to abkie py all caWitlarepr~nhd on this I Miat t: wsume full roapomsWqil fofc~ Ilance wMh ths Nflroat Ridps Building USB T7X : $20.25 andaHOFheraepNqti181Rrtroo Mpeordlnant•k,forworkuMxthbpeimk. _ Total: $53.25 Description: BUILDING DEPARTMENT USE ONLY Approval : SM 77117195 Zoning : R-1 Approvai: APProval : Occupancy : Walls KIDDER DEBORAH L 3370 SIMMS ST 18278 TUFF SHED INC 10' X 12' Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date Approval : / ~ (1) tlus pemwwa (2) abTft end~ ~ of -t (3) NtllispmPlRM l~ (6) in advanw r« di'fnpsclbne anil ehetl reaW wAlW wvrovaI m kapadiai cua eerore orro eMM not bs conetruatl b 6e a Penvid for, rar an sQprwal of, eM vidatkn oFthe PrwAebns THIS PERNNT VAUD ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPE CALL: 234-5933 24 HOURS PRIOR TO INBPECTION M Mechanieal lioense No : Company : Expiration Date : Approval : m Phone : 274-6639 Phone : 573-8833 Expiraqon Date : Approval : m u wepa eo n,e mwa a ms smee a caw.ao ana ro me zororo y(eU) tlaya trom uaue aeM «(s) me butlanp affiairaa brjsPwKW a nouM namaYY AVL*W,no dNrpu hNe 6ssn orwpl bs mWe in IM sxaestlstl one (1) year. ll dwqes rs nrtls a N weperniw~ a~arMonment NOTES. 1. IF UNIT IS PLACED WITHIN 3 FT. OF PROPERTY LINE, A 1 HR. FIRE WALL (UBC REM 75) WILL BE REQUIRED. 2. RAIN GUTTERS ARE REQ'D FOR ALL UNITS LARGER THAN 400 SQ. FT. 3. STRUCTURAL DESIGN BASED ON 1994 UBC. WIND LOAD 0 100 MPH ROOF LOAD MIN. 45 PSF (SNOW LOAD SEPEPATE). 4. NAIL SCHEDULE TO BE PER UBC TABLE NO 25 - Q. 3"X4" 20 CA CONNECTOR PLATE (MIN) 3"x4' 20 GA. CONNECTOR PLATE (MIN) -PRE-FABRICATED TRUSSES AT 24 ON CENTER 3"X4" 20 CA CONNECTOR PLATE - DOUBLE FASTEN PRE-FAB I 2X4 TOP PLATE TRUSS TO SIDEWALL USING FASTENER NO.3. MIN. 4 FASTENERS R TED 2' APA A 1/ DURATEMP SIDING r -2X4 STRUCTURAL STUDS = AT 24' ON CENTER CCA TREATED 4X4'S 0 24" I 6 O.C. RATED FOR DIRECT 2 t SOLE PLATE GROUND CONTACT 3/4 APA RATED TOUNC & GROOVE C 4X4'S USING T r- PLYWOOD ENED F I D 16d NAILS 0 n CROSS SECTION-/" 12 4 1/2" APA RATED DURATEMP SIDIN( 20 YEAR ROOFING SHINGLES OVER 1/2' -CD' EXTERIOR PLYWOOD. THIS STANDARD TUFF SHED PLAN IS DESIGNED TO MEET GENERAL BUILDING CODES. FOR THE SPECIFIC INSTALLATION LISTED HEREON, THE APPRO- PRIATE STANDARD DETAILS LISTED SHOULD BE USED. BUILDING ADDRESS: ~ ~ ,c~ e GtT pp BUILDING SIZE: r WIDTH: LENGTH: HEIGHT: STANDARD DETAIL SHEETS REQ'D: y= W AIAL S) ENGINEER: { OF CO UNIT DESIGNED FOR EXPOSURE 'B' PER SECTION 23111 (b) OF CURRENT U.B.C. D'METALFLASHING mLl,,lr'U"^- AP-t 2" X4' END WALL FRAMING 0 24" ON CENTER DOUBLE 2'X4' BUILT UP HEADER 1'X4" FORESTRIM 4060 DOOR STEEL DOOR LATCH 6' STEEL TEE HINGE CCA TREATED 47X4 0247 O.C. RATED FOR DIRECT GROUND CONTACT PER UBC CH. 25&29 (25-16J-C2) FRONT ELEVATION RN T UFF SHED 1777 S. HARRISON STREET SUITE 600 DENVER, CO.80210 (303)753-8833 THE B TECH MATERIALS CONSULTANT50 FAQUI 9605 WEST 49th AVENUE WHEAT RIDGE. COLORADO 80033 (303) 420-5020 (FAX) (303) 425-5671 RAKEWALL DOUBLE 2'X4' TOP PLATE 2W WALL FRAMING 24' O.C. 0 3 /e9! PREFAB TRUSSES - STACK FRAMING SIUL LLLVAIIUN DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : Date : Property Owner :Uk2I, 4) y ~ yK c5 ~ f-1 7 Property Address : 3 3?~ M S 5i - Contractor License No. : /g : . Company :`F(e f l= S I4 C,Q e i! Phone : Phone: S'~3 -~3E~3 3 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certiy Mat the setbadc tlistances proposed by this pertnit appliwtion are aecurate, and do not violate applicable ordinances, rulea or regulations of the City ot Wheat Ridge or covenants, easements or rastnctions of reeortl; that all measurements shown. and allegations made are accurate; that I have read and agree to abide by all contlitions pnntetl on this application, and that I assume full r6es onsibdRy for wmplianee with the Wheat Ridge Builtling Code (U.B.C.) and all other appliRS1e idqe ordinances, for woAc untler this pertnrt. (OWNER)(CONTRACTOR)SIGNED . DATE Description !4f4i o' (d ~ Approval : S.n.- Zoning :ft { ~ Approval : Approval : Occupancy : , BUILDING DEPARTMENT USE ONLY ~OX12' fRIVa'tfc STq2a,t~c ~1~Gb I~tuST T-bC-- 'S1~cr~ 15 ' 117¢01A~ Pa0P Ln_Zr4 L,1 ^lE ( SeGt: 2L- lo (l=) WN87.r" ~-to~c T~a~~lc~ op-vtr1P~~JC2~ Walls : Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval : J < Plgns;R&"qutced Plumbing License No . Company : Expiration Date : Approval : I, P[!hs Required _J Construction Value : ~ ~ , Permit Fee : Use Tax : Total : Mechanical License No : Company : Expiration Date : Approval : A (1) This permtt was Issuetl m ai RegNabons and BuilEing Ci (2) This permrt shall expire d(A a6antlonetl tw a penaE of 1 (3) If this pertnrt ezDires. a new onginel plans and speaRwt e.ceeds one (t) year. (uu fe (4) No work of any manner sha (5) Contrecror shall no6ry Ihe 8 (6) proceetl wiN su ssrve Tha ~s ce of a ermrt or ofth btling es orany rtlance with the pmvisions set forth in yopur aDPliwbon and is SuDject to the laws o( Ihe State of Colontlo and to the Zaning . of 1Mieat RiCge, Colorado or any other aOPlicable ordinances ot the City, e work au[honzeC is not commencetl within sixry (60) tlays from issue tlate or (8) the building authonzetl is suspentletl or ~Eays. rmit may De acquired /or a fee of one-half the amount nortnairy requtreQ provitletl no changes hava Deen or will be matle in the s and any suspension or abantlonment has not exceetletl one (1) year. If changes are matle or if suspension or abantlonment shall be paitl for a new permit. = tlone ihat wili change the natural tlow of water causing a tlrainage proDlem. ling Inspector hvenry-four (24) hours in atlvance for all inspecuons and shall recerve written apOroval on inspedion cartl before . iases of the job. . approval of tlrewings and specifcations snall not be wnstruea to be a pertnit (or, nor an approval of. any viola6on of the pmnsions ief ofQinance. law. rule or regulation. Inspector For Mayor PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION 1 ~ h ~ ~ ~ ~ ~,Se J P~ ~ j 61~f ~ Lot z ,.;I " F--- 5' Utility Easement s1 J l I I I E--4 ~ n p r , i 0 9 w FH I I ~ I I r. ~ O I o O E ~ I ~ ~ w I k 1\~ I ~ V~ J I C 01~ - - 23 I ~ C\4~ ~ ~ V ~r I I J "I I / V I LOT 1 , 20,883.96 SQ. FT. Appoximate ' Southerly limit 100 Yecr Flood Plain Existing Channel conditicns Lena Gulch Master Plan (1975) - S' Uh' Ease 1 68.50- GRAVEL DRIVE -Z LOT 3 19.624.20 SQ. FT ~ V < ~ o i,, GAR r 1 2' . . " 30 84 L , ~`'l ' 23 I 30 84 M 30 I I Fnd. No. 3 rebar i ~ S I I II 1 no cap LOT 14 ~ i I aI VA~LEY BROOK SUBDIVISON ~00 ~ C.E.I-6 I 2 STORY BRiCK AND FRAME. NO BASEMENT N0. 3370 SIMMS ST. - N89' I I. ! M v I O N N I N Corral I a Y , o z ~ I a ~ N ~I 27.04 ~ I ~ I~ o I 4 O o I ; y u I I LOT 6. I APPLEW00` SUB: DEI'/4RTMENT:OF PIANNINCa AND DEVELOPMENT " BUtLDING IM3PECTION DIViSION - 235-2855 ' CITY OP WtiEAT RIDGE Building Permit Number : 95-1518 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 mm Date :7/27/95 Properly Owner : Properly Address : 3363 SIMMS ST Phone : 2374170 Contractor License No. : 17888 Company : All Quality Roofing, Inc. Phone : 922 5769 OWNER/COWTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT ~ I Iroreby CeRIry that tho ietbedc distencea proposed by this pertnit application ere accurate, . af,M do noE vb-Iale app~lubIs drdinances, rules or rogulatbna of the City of Wheffi Ridye or : cGvdnanb, aeMemeMaov nsatrictiona of recorcl; that eA measunmanta shown, and albgations , tnar,(e are aqwraM; that Ihsw read and agree M abideby all contlftlona printed on Mis app9cation arb Mat 1 esswrue 1uA rosponsibN'~y for compfiarke wifh the Wheat Ridge BuiWing C~e (U.B:~C.) and ap otlrer appACeble Wheat RMge ordmences, for wodc under thia pertnk. (OWNERXCONTRACTOR) SI(3NED DATE BUILDING DEPARTMENT USE ONLY DesCripGon : REROOF 3-TAB Approval : Zoning : ' APProval ~ Approval: ' Occupancy : Walls EI@ctrical lieense No : Company : Expiretion Date : Approvai : (Z) ~ (3) (8) Roof : Stories Plumbing License No : Company : Expiration Date : Approval : 0 Residentlal Units : Mechanical License No : Company : Expiration Date : Approval: 0 oneeattatliinYoWraPWicetlonantlbaoect mmeWM anrosmreacoia.aoenamu,e aw,o-q . niAo or am other applinde ordinancea of fhe clly. ot wmmancetl wXhin efxly (80) days M1mn Isaue dste or (B) tlx buNdirp aWialzetl h suepanAed aor.e fee M one-heM Me amouM namaNY rotlulred,. Provded no cha'qa have Wxn u will hs matle In the or abaMOnmeM has not axceeded aro (1) Year. If chenpas are mWe a If susperubn a abandonment i~ I11ow of waror cawinp a MNnepe Probbm. wr (?A) houn In advance for aN mtperllons enM ehtll receive wriCen approval on inspectlon cmd baiore eM epeCiliestbns shall not De consWed to be a permR kr, nor an epproYel M, airy videtbn of 1he ProWelone W ths WNtlln9 cotles a enY ovror oramance, iaw, nne w repWatlon. {S~ i Cf Buildi nspector THi3 PERMIT VALID ONLYWHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234383524 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : Date : Properiy Owner : Property Address: Contractor License No. : 3363 Phone :,2,3717/ Company : Phone : 922 T7~ / OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : I hereby certify that the setback distances proposed by this permit application are accurate, Pg(mlt FE2 : and do not violate applicable ordinances, rules or regulations of the Ciry of Wheat Ridge or covenants, easements or resMCtions of rewrd; that all measurements shown, and allegations i Use Tax : s made are accurate; that 1 hava read and agree to abide by all conditions printed on th application, antl that I assume full re sponsibilit com liance with the Wheat Ridge Building it f k d thi ` s perm . or wor un er Code (U.B.C.) and all other appliwble i or ances, 7_ 27 ATE ✓v~~ Total : (OWNER)(CONTRACTOR) SIGNED D Description : / / Qr ~ MFY'19J~r - 3 14`j BUILDING DEPARTMENT USE ONLY Approval : Zoning : Approval : Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company: Company: Company: Expiretion Date : Expiration Date : Expiration Date : Approval : Approval : Approval : ~ • PI~!~ Aft~irill 4ns.R"lultetl ,I R111110acdw (1) This pertnit was issued in accortlance with the provisions set forth in yopur applicatlon antl is subject lo the laws ot the Slate of Colorado and to the Zonin9 Regulations antl Buildinq Cotle of Wheat RiGge, Coloratlo or any other applicable ortlinances ot the Ciry. (2) This permit shall expire if (A) the work authorized is not commenced wilhin sixry (60) days fmm issue dale or (B) the building authorized is suspentletl or abantloned for a penod of 120 days. (3) If this permit expires, a new permR may be acquiretl for a(ee of one-half the amount normalty requireQ providetl no changes have been or will be made in the original plans antl specifications antl any suspension or abantlonment has not exceedetl one (1) year. If changes are matle or if suspension or abantlonment exceeds one (1) year, full fees shall be paid for a new permit. (4) Nb work of any manner shall be done tfiat will change the natural flow of water causing a drainage problem. (5) Contractor shall notiy the Builtling Inspector twenty-fow (24) houre in advance for all inspedions and shall receive wririen approval on inspection cartl before proceetliing with successive phases of the job. (6) The issuance of a permit or the apProval of tlrawings antl specifcations shall not be consVUed to be a permit for, nor an approval of, any viola6on of the provisions of the building cotles or any other ordinance, law. rule or regulation. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION 7500 WEST 29th AVENUE 237-6944 EXT. 255 P.O. BOX 638 PERMIT VALIO ONLY DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING INSPECTION DIVISION CITY OF WHEAT RIDGE, COLO. THE GHIEF AND RECEIPTED_BELOW. PERMIT NO.ME91#4879 c 33~j ~ $ DRESS S' } ' OWNER ~ - ~ JOB AD 'I o13 PIY n 0~'n -s 5 ADDRESS 8~zr~t CODE CONTRACTOR/ A! S' 7pp~ _ZIP pHONE ~ ADDRESS CONTRACT PRICE $ ZIP CODE CITY 02- ~ 2( DATE / a32''~'~'$~s LICENSENO . PHONE ound❑ G Woll❑ Proiectinp❑ Oth*r 5 w D Face r I. TYPE Totel Squme Fpt 2. M1ITERIAL ❑ NoU Y Typ° Elect. Pomit No. t aa SIGNS 3, ILIUMINAT10N E o~ ~ ADM~'b~ Z~~ ~nap~t Zone W 4 SET BACK FROM PROPERTY LINE N- 5-~ - E] ~ ' Disapprwed Cl 0 (SDacify which ia front ) lidC Mon Thon 80% ODenCl S Less TAan 80% OMn o 1. TYPE Haiphf ?,MATERIAL FENCES E N g S w Zom_- ADWa'b,Zoro Inspee w 3. SET BACK FROM PROPERTY LIN ❑ ❑ ❑ ❑ piaopproved (SDecify whieA ie tront) OTHER 2 - a. INSPECTION TICKET DRAW SKETCH OR SNOW BELOW,TNE FENCE,SIGN,OR OTHER (SETBACKS OR PROJECTqNS INCLUDED) STREET NAME THIS APPLICATION WILL BECOME A PER PERMIT WILL EXPIRE 180 DAYS FROM THE 1 hsreby acknowledqe tnat this a001ico- tion is cOrrect ond understand ihai I cannot start thie projeci until Ihia apDli- totion if a00roved. I shall comDly with iM lawf oi the Stote af Colorodo and 10 the Zoninp Repulnlions and Bwidin0 Code of1he City of Wheot Ridqe. QnY violotion ol Ihe above rorma will couse immediale revocahon of INa permil JOB ADDRESS DATE: ~ BLDG. PERMITB ~ c PERMITB =Y NORTH BLDO. CONTR 0-9-~ SUBCONTRACTOR DATE INSP. REQ. TYPE OF INSR CAIL 237-6944 EXT. 255 24 HOURS IN ADVANCE FORINSPECTIONS SHNSTY UNSBNOT Df MAXMUM J OR 1 DISTANCE TO PROPER AVERF r2- I C7- INSPECTION MADE APPLICATION FOR PLUMBINC rioN oivisioN. MIT TO PERFORM THE REMARKS