HomeMy WebLinkAbout6650 W. 44th Avenuei M CITY OF WHEAT RIDGE Btiiding<Inspectiod4bivision (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 5�'7J i - ✓ Permit Number: , 1<!7 pD / / '7 ❑ No one available for inspection: imeO 'SEAM M Re -Inspection required: Ye Nom When corrections have been made, call for re -inspection at 303-234-5933 Date: 4-/ 9 % Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building In pection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address:— Permit Number: ❑ No one available for inspection: Time Re -Inspection required: Ye -No When corrections have been made, call for re -inspection at 303-234-5933 Date:_3 inspector: DO DO NOT REMOVE THIS NOTICE City of Wheat Ridge Commercial Sign PERMIT - 201900117 PERMIT NO: 201900117 ISSUED: 01/22/2019 JOB ADDRESS: 6650 W 44th Ave EXPIRES: 01/22/2020 JOB DESCRIPTION: Commercial free standing sign. 84 X 60, total height is 84 X 72. 4 X 4 posts, 1 X 4 slats. 3 12 feet caissons 2 feet deep wide. *** CONTACTS *** OWNER (720)524-3477 CRACK AND NEEDLES, LLC SUB (303)232-2144 DAVID PETERSON 180052 DAVID PETERSON CONST., INC *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: 520 / Office; 0 USE: UA / Unassigned BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 500.00 FEES Total Valuation 0.00 Plan Review Fee 17.23 Use Tax 10.50 Permit Fee 26.50 ** TOTAL ** 54.23 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, anall applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be per ormed is disclosed in this document and/or its' accompanying approved plans and specifications. r a'ture of OWNER orCCONTRACTO - 4Circle one) Date This permit was issued base-don'tneinformation provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. This Penn shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. If this permit expires, a new permit may be required to be obtained. Isuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. The issuance or grantingf a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicalde or any oripance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date 2EQUESTS MUST BE MADE BY 11:59PN ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of' lW h( ---at I�gc RSC-uiV Building & Inspection Services Division 7500 W. 291' Ave., Wheat Ridge, CO 80033 ) Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a-)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: / , A ")_ C Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 6D X1)3 3 Property Owner (please print):Ci !dC4 A le -ed JAS, L -4-C Phone: rlo2Q-- 5311-• 31%7 7 Property Owner Email: J �'iU' I -j Q 9- T -I- � �f �� [.� JY) (+ i L , CO Y" Tenant (Commercial Projects Only) -6` Property Owner Mailing Address: (if different than property address) Address: 1'� m8L\ ' City, State, Zip: Architect/Engineer: IJo _ Arch itect/E ng 1 neer E-mail: Phone: Contractor: C,t V l d 2r' beil-5 ol- o ll4- 6 i -k -U C-4-7 D .0 (,u C- 1 _ Igdvs2 City of Wheat Ridge License #: 1,4-0-6-3-&&-3 & Phone: 303 a 31 -a �( Contractor E-mail Address: D t- Ike. I C it S O /,/ L P ryt s 0, C bv� For Plan Review Questions & Comments (please print): CONTACT NAME (please print): .t Jcz v i A f e �C Phone: 7JL0 3 1�7 ( ) G q 3 CONTACT EMAIL(p/ease print): 1::) L_ ?if 16 d Al f" S YV-\ Sub Contractors (Must provide Wheat Ridge License No.): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Q COMMERCIAL F-1RESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. W 5-tA u. r�e�st�a �d��y 5 cab . 516N �S '3Lf c,U�` 9�X -7L CO VASA u G i e- 0 tcj Lf )( Ll p -t --5 ; 1 X H ?'i n e S (af 3 i ';L" Cat 1 SS 0Yl S e t c c L j ir.1 S� f- C) rac-K Ei5 Commercial Projects Only: Occupancy Type: Construction Type: ` illc _ Sq. Ft./LF BTUs Amps Squares Gallons Project Value: (Contract value or the cost of all materials and labor included in the entire project) s 5d D oo OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, riles or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) orUTHOR!lED REPRESENTATIVF of (OWNER) CONTRACTOR Signature (first and last name): 11�' i pC � Y ✓ DATE: Printed Name: 1L-0— s Ll 11.110ENIT USE ZONING COMMMENTS; -� _ St'JQ /bV� L+ Ok . OCCUPANCY CLASSIFICATION: tJ Dr�wreoC 'at( reol t: �e c'o✓�t c -ii trK S CONSTRUCTION TYPE: Reviewer: BUILDING DEPARTMENT COMMENTS: iRi U fY W J`� L�- [ r /I e 'T l—r` —7 C T ii PIS Reviewer: PUBLIC WORKS COMMENTS: Reviewer: Building Division Valuation: ep s r Freestanding Sign Calculation Sheet You must complete this sheet and include it in the submittal package for any new freestanding signs. You will also need to create a site plan and a detail sheet of the signage. l0 5-p C) ggth da't Contractor: Duid P krn'tL " You are allowed 1 freestanding sign for every street right-of-way adjacent to your property. The allowable sign size is related to building size. 1F E D Step 1: Determine the square footage of the building: ------- Building size (in square feet): rj (This will be inserted in the formula below) Step 2: Complete the appropriate allowable signage formula: If the building is 0 -1,500 square feet in size, you are allowed a 35 square foot sign. If the building is 1,501 - 5,000 square feet in size, complete the following: - 1,501 = _ 50 = + 35 = Building size Allowed sign size If the building is 5,001 - 50,000 square feet in size, complete the following: F503 �Z.- - 5,001 =_ 3J7. 500 = �, CU �. + 100 Building size Allowed sign size If the building is 50,000 + square feet in size, complete the following: - 50,001 = _ 1,000 = + 190 = Building size Allowed sign size The "allowed sign size" may be placed on each side of the freestanding sign. Check here if the sign is existing and you are replacing a cabinet or face with the same size cabinet or face. Continued on back The sign must meet a setback from the street right-of-way. If the sign is less than 7 feet in height, the sign must be setback 5 feet. If the sign is between 7 feet and 15 feet the sign must be setback 10 feet. For most freestanding signs, the maximum height is 15 feet. For properties within'/4 mile of the interstate, freestanding signs may be 50 feet tall. These signs must be setback at least 30 feet from the street right-of-way. Step 3: Determine the height of the new sign: r The new proposed freestanding sign will be feet tall. Step 4: Determine the setback from the street right-of-way: The new proposed sign will be setback feet from the street right-of-way. All freestanding signs must adhere to the sight distance triangle requirements as listed in Section 26-603 of the Code of Laws. You must include a site plan which details the location of the freestanding sign, building and drive areas. Show all new and existing signage (include the square footage and height of all existing signs). Please include a detail of the proposed sign, including the overall square footage and height, as well as any electrical and structural details which may be pertinent. b File 16000311158 Stewart Title Guaranty Company 2/16/2017 10:11 AM Buyer's Closing Statement Stewart Title Guaranty Company, Denver 55 Madison Street, Suite 400, Denver, CO 80206, (303) 331-0333 Escrow Officer: Brianna Corwin Buyer(s) Crack and Needles, LLC, a Colorado limited liability company, 6650 West 44th Avenue, Wheat Ridge, CO 80033 Seller(s) John A. Bower, 3061 Oak Street, Lakewood, CO 80215 Sharon L. Bower, 3061 Oak Street, Lakewood, CO 80215 Lender(s) Bank of the West Bank of the West Colorado Lending Source, Ltd. and U.S. Small Business Administration Property 6650 West 44th Avenue Wheat Ridge, Colorado 80033 Closing Date 2/17r'2017 Disbursement Date 21171'2017 Proration Date 2/17;2017 Debit Credit Sales Price/Consideration Contract sales prier. S510,000.00 New Loan Principal amount of new, loan's) ' 5255,000.00$204,000 Second and subsequent loan's) 00 Deposits Earnest money $10,000.00 Prorations Sewer Paid $45.00 January - March Prorated 2/17/2017 to 4/1/2017 11 $2'.21 County ax Proration -Based on $5,097.10 1!112017 to 2/1 7/2017 . $65634 Wheatndge Santation paid 2/17/2017 to 4/1/2017 @$45.00/q;r $21.50':' Rent Pro ation - No Secruity Deposit 2/17/2017 to 3/1/2017 $700.00/mo _ .__.. �.._._...._... _ $300.00 New Loan Charges .. Intermim Loan Fee (Partial) to Bank of the West $550.00 Loan Ori ination Fee to Bark of the West -• Origination _ E'OCB $1,27 00 Packaging Fee to Clank of the West POC B $800.00 Appraisal Fee to Bank of the West POCB $2,200.00 interim Loan Fee (Partial) to Bark of the West POCB S725.00 Title Charges Real Estate Closing Fee to Stewart Title Convnercial Services - Denver _. $250.00' Loan Closing Fee to Stewart Title Commercial Services - Denver _ . $300.00 Title insurance to Stewart Title Guaranty Company Lender's coverage $255,000.00 $150.00 X540.00; - ALTA 9 $170.00 - ALTA 22 $85.00 - ALTA 8.2 $50.00 - ALTA 41 $85.00 ..9 ...... _.. Lenders Covera e $204,00911.90 $150.00 1 $150.00 3rd Loan Policy to Stewart Title Commercial Services -Denver POOL $439.60 ALTA 22 to 3rd Loan Policy to Stewart Title Commercial Services - POCL $85.00; Denver ALTA 41 to 3rd Loan Policy to Stewart Title Commercial Services - POCL $85.00 Denver Tax Certificate to Ste ` wart Title Commercial Services -Denver $30.00...._. ,. Recording Fees/Transfer Charges Recording Escrow $400.00 State tax stamps $51.00 Additional Charges Water Transfer Fee to City of Wheatridge _. $25.00 Subtotal: $512,338.71 $469,956.34 Balance due from Buyer: $42,382.37 R E C C I V ELE) Totals: $512,338.71 $512,338.71 « Per Page 1 Scott Cutler From: Scott Cutler Sent: Tuesday, January 22, 2019 2:35 PM To: 'dlpeterson1 @msn.com' Subject: 6650 W 44th Ave - Sign Permit Hi David — I'm reviewing the freestanding sign permit application for the project at 6650 W 44th Ave (Permit #201900117). Everything is approvable with a couple red -line corrections. Please note the property line for this property is actually 3' behind the sidewalk and the sign must be set back 5' from that line. That means the front edge of the sign would need to be set back 8' from the sidewalk edge, not 5' as shown on the plans. We will confirm this placement in the field and can go ahead and approve the permit with a note stating as such on the plan sets. Let me know if you have any questions. Thanks, Scott Cutler Planner II Community Development Department 7500 W. 29th Avenue Wheat Ridge, CO 80033 Office Phone: 303-23S-2849 www.ci.wheatridge.co.us CONFIDENTIALITY NOTICE: This e-mail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you. 0 S S In T �1 Reviewed for Zoning Compliance by the ► t City of Wheat Ridge Planning Division P11- BY: APPROVED BY: 5reM C�,-rL. DATE: l / �Vt / (4 COMMENTS: few -b GvrfQe� R E Q,- •a IJ T) 4%0%city Wheat Building Lr) City cit Vheat�d e j�KOMY DEVEIOPMiENT ED APPROVL. Reviewed for Code Cornr,'iance Plans Eimer pate 100ftsfate!8: The ksuare of o peeeW or sxvarrd q/p1m mBnveq�edatvm asgq not be opermi far, or oA spprwdei eery otalWao so 01p of the Pav Wft 01" fir, Co* of 61"y%tr e><'*'wnm. peer�t a P vxar*V to 9e to Wao efoaroe►At pewbsam of Me owes or~ 00,40A is of Me car twMt6e solid 9� T �1 Reviewed for Zoning Compliance by the ► t City of Wheat Ridge Planning Division P11- BY: APPROVED BY: 5reM C�,-rL. DATE: l / �Vt / (4 COMMENTS: few -b GvrfQe� R E Q,- •a IJ T) 4%0%city Wheat Building I Size detail Rendering of sign in proposed location Photo rendering of completed sign 1 • POOTED IN TRADITION ACUPUNCTURE Ca 4� e -:l 5 v A ), 115re4a: �/ 4211, Finished re (min.) diameter pier r] 4 Trhea T -e -D pct 1"s W6 4e Aj& L) P —:;L:) C, <j z 10 n'd a Oyroy7�p0 a ti CD O O co n ti rt m (D (D Hrr n ►� :17 CrJ "� e9 p P 'k w o rt n O N : 6 'C a En R° 00 b rr Zo�dO211 00 p. ^* w O H x Gi cc M, a b O � °, `� c �• mac Imo, P. m 0 ". C1 ` CD , to Y mwm fro`° C7 �O¢ �, 0 n y p rr E rr P1 00 rA CO. °! A W �{ nC O o lq F" O [ns] N �o ! �f O x m� re C, a H m ,�v,,, O � cG n 0 oo V �l OO F' 0yCDo. ft� n rpt OV n w rm C °' ., ,. t4 000 117 .° fD rp C ~Cr 131 V � OCD° a b a rA UQ WC Q(rQ pa krtrr 00 o QTR b r c 3 �77,O " ° CD n � Q° y d o ry O S o "a d x � sa a I d o 00 ity of wl�catidle BUSINESS LICENSE INSPECTION PERMIT NO. 201700828 BUSINESS NAME: B & L Industries, LLC ADDRESS: 6650 W. 44th Avenue CONTACT NAME: Robert Ogarek S 910 V SQ FT I� OCCUPANCY TYPE & OCCUPANCYLOAD lt07) CONSTRUCTION TYPE ® SPRINKLERED _ n h ci 4-e- 41 e- n NON-SPRINKLERED Inspector Signature -7 l Date INSPECTION DAY/TIME Mon., May 21 st @ 9:30 AM INSPECTION DAY/TIME Mm V u 6� INSPECTION DAY/TIME f o CITY OF WHEAT RIDGE, Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F31-17- \c e,► se Job Address: (v 6 S- V w 4i I/ +�h A L,�e Permit Number: '-d o 1 -7 0 0 8 -,7 <R S a. moi- = S- S o d 3 L=- A PF t`o ueG ❑ No one available for inspection: Timet 0 = L) lo &PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303 -234 - Date: --7 / 0 Inspector: —r7b DO NOT REMOVE THIS NOTICE 0 =3G i CITY OF WHEAT RIDGE _1�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 6& L;U W l , Permit Number: 2or7z?7 ),?' ry1rs -2a 4 2�q ��sl,l. Grp Ou�1_-rte W�1til t ' 1 0 F 1 �� ❑ No one available for inspection: Time I A PM Re -Inspection required: Yes No When corrections have been made, call for re -in pection t 3 -�-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE SUS►K 5�5 o c �7bbnO o�xoz S �. CD tgLn 0 y Q., y, (p fD ri a� n A es A + P- 0. b. m m �yi� a I-ja� 0 I -h a O � r � d< , n m N Ood'�x o h tr C r. (D' p C7 \ 1 rn 11 LQ (D'� h �.. r= �I y y Baa �n"•�-- ay z b ra LV rif `� .� E ° �o w CL ! A tq r tn=J e9 °EQ g ~ H m (D Ila p n ° O O H p a c o o rr M p A9 w p !� ., i� rr n ~ N F Oil Q O n� n A C WQ Ln ^ Ktz a `t O "� r- c °CD o @ r•r w n A �y d n C� o r a a co 10 00 PERMIT NO. 201800746 City of Wheat 1<i!ge- BUSINESS LICENSE INSPECTION INSPECTION DAY/TIME Tues., June 12, 2018 @ 11:00 AM INSPECTION DAY/TIME INSPECTION DAY TIME ' BUSINESS NAME: Soul Body Health LLC ADDRESS: 6650 W. 44th Avenue CONTACT NAME: Leslie Huddart (h SQ FT OCCUPANCY TYPE OCCUPANCYLOAD .9� n CONSTRUCTION TYPE ZIP ❑NPO KLERED N-SPRINKLERED i Inspectoognature /') %r - Date A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: & J' Job Address: n A) � Permit Number: 00 &V 7 Re -Inspection required: U�esNo When corrections have been made, call for re -inspection, at 303-234-5933 Date: '�� ' Inspector: rI- �� DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: lf% 4/0 Permit Number: �,;)o Fn E>- z c ❑ No one available for inspection: Time �> Re -Inspection required: Yes CNo _z When corrections have been made, call forr e-inspectionat 303-234-5933 Date:-/—/. /V Inspector: � DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: `109 ` rI/M L t_1_ CO/" Job Address: 6650 W 91/77-/ I - IVC Permit Number: Z01,9 00S-)3 9L4, a 41 ❑ No one available for inspection: Tim M/PM Re -Inspection required: Yes No When corrections have been made, call f'r re-inspectsn at.3Q3- 34-5933 Date: Inspector - DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTIC f% Inspection Type:G Job Address: f %1/ Z/y/' Permit Number: j ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes (No When coo ns h ve been made, call for re -inspection at 303-234-5933 Date: ? /� Inspector: DO NOT REMOVE THIS NOTICE 00 r4 > m 7 m O (y AO m v c m w m � v \ Fi m m tip � � N tai z M � m O m N • • m m m .0 Gj m (d w a O Q Nm o rn C p U Ol 04 _ m o m ri U ••+ U A tA a m O o p O m a m o A N w O b) 4J U O ro N w 7 ao o a m d a o 4.) H a PA m m T� V �✓ �;� o b m W ) i r I O W M O o a m N y O N C)00 �4 m a S b w a 44 '�I O 4J A N L w x U O 4 3 '� W •{y '1 a m N O jw a u�i o o 3 a N o U � C 0 ri V w G) N CSI U� Q v N U � F• O p' A r� rZ `noma" H e ro N a MlN cd3 0 VU W m vo ro d N A U 41 V x o y. v x ri ri 11 o 'd 3 m 0 ro Li Id v 'Q b W a 01 it .0 I. F •' m w A A El O 4 04 , U G 4) � y w m o N > p u a q a Id 44 dl Wro "+' 41 .401 " 44 U O al Ux , +>' U a w v w p rpi A p U O ° 41 a q a o a " 3 z H O �b a co I y m -A m w w a o a N N a .i N 1 ; o wN N O o a U V. G) O v m z [a .. o z 4.) w H ami s+ a ti x m r a a N U N1 A p q x a W \ ri 4-)'C% .y WO m D U U F W spa b U C� W J�) !y �4 N 0. ++ m ro WW. a U F m N Um O p (24y v x m q zo 3 O x a a a O v m o U W F a m O U W a u. U ry City of W _;�q"`heat e g PERMIT NO. 201800476 BUSINESS LICENSE INSPECTION INSPECTION DAY/TIME Thurs., March 8th at 9:30 AM BUSINESS NAME: Holistic Physical Therapy, PC ADDRESS: 6650 W 44th Ave., Suite 1 CONTACT NAME: Jennifer Lane SQ FT � t15'x Is, Y�� OCCUPANCY TYPE 3 "�- OCCUPANCY LOAD PRINKLERED NOWSPRINKLERED i CITY OF WHEAT RIDGE _1�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: • A -v , , to Permit Number: 0b(?00 7( ❑ No one available for ins ction: Time 6730 AM/� M Re -Inspection required Yes No When corrections have been ma e, call for re spection a 303 234-5933 Date: 3611Y Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge t Commercial Plumbing PERMIT - 201800573 PERMIT NO: 201800573 ISSUED: 03/12/2018 JOB ADDRESS: 6650 W 44th AVE EXPIRES: 03/12/2019 JOB DESCRIPTION: Relocating sink in existing bathroom utilizing existing drain and water supply. Removing a non-bearing wall. Removing one outlet and relocate one outlet. 50 square feet. *** CONTACTS *** OWNER 1,303)304-7339 GC (303)232-2144 SUB (303)929-9779 SUB (720)296-7972 DR JEN HARTLEY David Peterson Steven J. Tucker Trevor Harbey 180052 David Peterson Const., Inc 170414 Fiber -Tech Electric, Inc. 130129 Afford -A -Rooter *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 520 / Office; 0 BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,000.00 FEES Total Valuation 0.00 Plan Review Fee 70.98 Use Tax 84.00 Permit Fee 109.20 ** TOTAL ** 264.18 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION City of Wheat Ridge Commercial Plumbing PERMIT - 201800573 201800573 6650 W 44th AVE Relocating sink in existing bathroom supply. Removing a non-bearing wall. outlet. 50 square feet. ISSUED: 03/12/2018 EXPIRES: 03/12/2019 utilizing existing drain and water Removing one outlet and relocate one I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be p �---� .:.. P. �' 4r accompanying�pp ved plans and specifications. performed -and ormed.and that all work be performed is disclosed in this document and/or its' approved Signature oi�_OWNER or CONTRAC R (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying Flans and specifications and is subject to the compliance with those docun�nts, and all applicable statutes, ordinances, regulations, policies and procedures. 2, This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Buildin " V ate REQUESTS MUST BE MADE B Ir- Al BUSI D FOR INSPECTION THE FOLLOWING BUSINESS DAY. City Of Wheat p..j,dg COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(@ci.wheatridae.co.us I FOR OFFICE USE ONLY I Date: A/ / Plan/Permit # Plan Review Fee: �$ r7(-, - 9g Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: & & 1_0 ty '5 i- q 444A (+L' e _ Owner Phone: _3i; Property Owner Email: D R Te 0 14 K ► LF_ `/ C M'CLC . CD rvi _ Mailing Address: (if different than property address) Address: ti2.4,1 City, State, Zip: Architect/Enaineer: /'j It � Arch itectlEng1neer E-mail: Phone: _ Contractor: D Qy c d Lj: ('5lM &5Y\ S,T-9-Q CV0 AJ ki G Contractors City License #: O bD52- Phone: A0 � -,:�S D, Contractor E-mail Address: D� - CSC e ie, S0 nJ -J— C ►1'l S V1 - C 0 w\ For Plan Review Questions & Comments (please print): CONTACT NAME (please print): (d P -&f --e_. r -s rv" - Phone: 7ao CONTACT EMAIL(p/ease print):L Pe—T--e— rSO N fy1S1) -CC Sub Contractors: (- Electrical: 6 -her -kc ki ElectG AAA—Plumbing: f}%F0&1)—/4 - f,0 Cil _e f'- Mechanical: W.R. City License # W.R. City License # W.R. City Licerr I V E D -)'gjv-7, 00-06-7$7z a Other City Licensed Sub: Other City Licensed Sub: MAR 112011, City License # rr City License # /� Complete all information on BOTH sides of this form ,COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT 9K PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ig ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) JZeL,04ATWtJ Sluyc IN SFrAJ6 B,-71+P-ccyM Ur Ltz��rG � cs� DK,Atm .4 Wa-+or S,;Fr iy. m ge-, o ve 2xrs f fA6 wrt Sq. Ft./LF Amps S-0 Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ foe) vc OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONT_ ACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): DATE: N I DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: /' S U Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: 1� 3//phr Building Division Valuation: City of Wheat j�ge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W 291b Ave Wheat Ridge CO 80033-8001 P• 303 235 2855 F• 303 237 8929 Job Address: 6650 W 44th Avenue Date: March 12, 2018 Type: Single family dwelling bathroom remodel Plan Check No.: 201800573 This review is limited to the contents of the plans submitted and any errors or omissions contained herein shall not be construed as permission to allow any conditions to exist in violation of the codes and the City of Wheat Ridge amendments. The City of Wheat Ridge adopted the following Codes known as the city of Wheat Ridge Building Codes: • 2012 International Residential Code (IRC) • 2014 National Electrical Code (NEC) • 2012 International Building Code (IBC) • 2012 International Fuel Gas Code (IFGC) • 2012 International Mechanical (IMC) • 2012 International Energy Conservation Code (IECC) • 2012 International Plumbing Codes (IPC) • 2012 International Property Maintenance Code. (IPMC) • 2012 International Fire code (IFC) • City of Wheat Ridge Municipal Code and Amendments This project shall comply with the following checked items and all applicable provisions of the adopted codes, city of Wheat Ridge Municipal code and amendments above. General 1. ❑ This projects foundation is placed within 24 inches of the required setbacks. As part of the foundation inspection and PRIOR TO POURING OF THE STEM WALLS, a completed, signed and sealed, Foundation Setback and Elevation Certification shall be submitted to the City for review. The certification form shall be fully completed by a Professional Land Surveyor licensed in the state of Colorado, stating that the foundation was constructed in compliance with all applicable minimum setback and elevation requirements to the city. 2. ❑ Burial depth requirements: A Electrical —direct burial conductors shall be a minimum of 24 -inches deep, non-metallic conduit 18 -inches deep or 24 -inches under driveways. (IRC Table E3803.1) B Water Lines - shall be a minimum of 36 -inches deep. (IRC P2603.6) C Gas Service Piping -installed a minimum of 12 -inches below grade or 8 -inches below grade where serving individual outside C.�►, � Y0 appliances. An 18 AWG yellow insulated tracer wire must be installed adjacent to underground nonmetallic gaT"' i i1 e terminate above grade at each end. (IRC G2415.1.2 and G2415.17.3) uNttY ❑ Underground plumbing pipe shall have a solid and continuous load-bearing support. Piping cannot bear on rocks. Pipesppassi, a under a footing or through foundation wall shall be provided with a relieving arch or a sleeve. Trenches parallel to footing shall not extend below the 45° plane of the bottom edge of the footing. Water piping must be buried a minimum 36 -inches dee service pipe may be installed in the same trench as the building sewer provided the sewer pipe material is listed for underground use within the building or the water service pipe is separated from the sewer by a minimum distance of 5 -feet horizontally o elevated at least 12 -inches above and to one side of the sewer line. City of ��E,y„sr tNheat Ridge Document 1 �Bullr1 Page iinn �:..:-- 4. ❑ Exterior finish materials must conform to the conditions of your Site Plan Review to include: roof covering, siding, ignition resistant construction, color requirements, conforming light fixtures which are reflected on the approved lighting plan, and re - vegetation requirements. Foundations, Floor Assemblies & Slabs 5. ❑ Frost depth to the bottom of the foundation footings must be as noted on the engineered plans. If not noted, the frost depth to the bottom of the footings must be a minimum of 36 -inches below finished grade. (IRC TableR301.2.1) 6. ❑ Caisson and helical pier foundations shall be inspected by a qualified, Colorado -licensed Engineer, who must witness the placement, drilling, and reinforcement of drilled piers. A signed, sealed and dated inspection report must be provided to Building Inspection Services prior to the rough inspections (RI 10.5.2.3) 7. ❑ A perimeter drain system that discharges to an approved drainage system is required around all foundations that enclose usable spaces below grade. Foundations that retain earth and enclose interior spaces below grade must be damp proofed. (IRC R405.1, R406.1) 8. ❑ Slabs below grade must maintain a minimum of 6 -inches above the design water table. The interior finished crawl space grade must be a minimum of 36 -inches above the design water table. (R401.2.1.3and R401.2.1.5) 9. ❑ Garage floor surfaces must be of approved noncombustible materials. Floors must be sloped to facilitate the movement of liquids to a drain or slope a minimum of 1/4 inch per foot toward the main vehicle entry doorway. (IRC R309.1) 10. ❑ Foundation plates and sills must be bolted to the foundation wall as prescribed on the engineered plans. If not noted, bolts shall have a minimum diameter of/z-inch, embedded at least 7 -inches and spaced not more than 6 -feet apart. A minimum of 2 bolts are required per plate section, with one bolt located within 12 -inches of each end of each plate. (IRC R403.1.6) 11. ❑ Accessible under -floor areas shall be provided with a minimum 18 -inches x 24 -inches opening through the floor or 16 -inches x 24 -inches opening through the perimeter wall. When the access is through a below -grade wall an areaway of not less than 16 - inches x 24 -inches must be provided. Where equipment is located beneath the floor, the access opening must be within 20 -feet of the equipment and allow the removal of the largest piece of equipment. (IRC R408.4 and M1305.1.4) Structural 12. ❑ The complete rough inspection is to be made after the rough framing, rough electric, rough plumbing, and rough mechanical are complete. The building should be fully enclosed with the roof covering and siding in place. 13. ❑ Protection from decay shall be provided in the following locations by the use of naturally durable wood or wood that is preservative treated in accordance with AWPA U1: (IRC R317) A Lumber, plywood, fiberboard, structural logs, and glued laminated timber must be identified by a grade mark or certificate of inspection issued by an approved agency. (IRC R502.1, R602.1, and R802.1) B Wood joists closer than 18 -inches and wood girders closer than 12 -inches to grade located within foundation periphery. C Wood framing members that rest on concrete or masonry foundation walls and are less than 8- inches from the exposed ground. D Sills and sleepers on a concrete or masonry slab that is in direct contact with the ground. E Wood girders entering concrete or masonry walls with a clearance less than 1/2 -inch. F Wood siding, sheathing, and wall framing less than 6 -inches above the ground. G Wood members supporting moisture -permeable floors or roofs that are exposed to the weather. H Wood furring strips or wood members attached directly to the interior of below grade exterior masonry or concrete walls. I Wood in contact with the ground, embedded in concrete in direct contact with the ground or embedded in concrete exposed to the weather that supports permanent structures intended for human occupancy shall be approved pressure -preservative - treated wood. c; rya f Documentl ���?Page 2 of 11 t r 14. ❑ Columns must be restrained to prevent lateral displacement at the bottom end to insure against uplift. (IRC R301.2.1, R407.3) 15. ❑ Fire blocking shall be installed to cut off all concealed draft openings in the following locations: (IRC 302.11) A In concealed spaces of stud walls and partitions, including furred spaces, vertically at the ceiling and floor levels, and at 10 - feet horizontal intervals. B At interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings, and cove ceilings. C In openings around vents, pipes, ducts, cable, wires, chimneys, fireplaces, and similar openings that afford a passage for fire at ceiling and floor levels. D In concealed spaces between stair stringers at the top and bottom of the run, and between studs in line with the run of the stairs at unfinished walls. 16. ❑ Rafters must be framed to a minimum 1 -inch nominal ridge board that is not less than the depth of the cut end of the rafter or to each other using a gusset plate. Hip, and valley rafters shall be a minimum of 2 -inches and not less in depth than the cut end of the rafter. Hip and valley rafter shall be supported at the ridge by a brace to a bearing partition or be designed. (IRC R802.3) 17. ❑ Rafters and ceiling joists having a depth -to -thickness ratio exceeding 5:1 shall be provided with lateral support at points of bearing to prevent rotation. Rafters and ceiling joists having a depth -to -thickness ration exceeding 6:1 shall be supported laterally by solid blocking, diagonal bridging or a continuous 1 -inch by 3 -inch wood strip nailed across the rafters. (IRC R802.8) Roof trusses or rafters must be attached to supporting walls with approved hurricane clips. Trusses must be braced to prevent rotation and to provide lateral stability in accordance with the construction documents and the individual truss design drawings. (IRC R502.11.2, R802.11) 18. ❑ Trusses must be designed and fabricated in accordance with ANSI/TPI 1. A licensed professional shall prepare the truss design. Trusses must be legibly marked within 2 -feet of the center to identify the manufacturer, the design load, and the spacing. Truss engineering and layout must be provided at the site at the rough framing inspection. (IRC R502.11 and R802.10) 19. ❑ The city of Wheat Ridge Wind Exposure category is 110 mph with 3 second gusts. Shingle installations shall meet the manufacturer's high -wind installation procedures in areas where wind load is greater than 105 mph 3 sec gust. Wood shingles shall be fire treated. (R301.2.1, R325). 20. ❑ Floating Walls: In areas subject to floor heaving, non-bearing walls on basement floor slabs should be built to accommodate not less than 1-1/2 inches of floor movement. Drywall should be held a minimum of 1 inch above the floor slab to allow for movement. Egress, Emergency Escape & Rescue Openings 21. ❑ Emergency escape and rescue openings shall meet the following requirements: A minimum clear width of 20 -inches, a minimum clear height of 24 -inches, with a total net clear opening of 5 square feet for grade level windows and 5.7 square feet for all others. A sill height of not more than 44 inches measured from the finished floor to the bottom of the clear opening. Window wells for emergency escape and rescue shall provide a minimum net area of 9 square feet with minimum horizontal projection and width of 36 -inches. The area of the widow well shall allow the emergency escape and rescue opening to fully open. (IRC R310) 22. ❑ Basements greater than 200 square feet and every sleeping room shall have at least one operable emergency and rescue opening or a door to the exterior. 23. ❑ At least one egress door shall be provided for each dwelling unit. The egress door shall be side -hinged and shall provide a minimum clear width of 32 -inches (813 -mm) when measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). The minimum clear height of the door opening shall not be less than 78 -inches (1981 -mm) in height measured from the top of the threshold to the bottom of the stop. Other doors shall not be required to comply with these minimum dimensions. Egress doors shall be readily openable from inside the dwelling without the use of a key or special knowledge or effort. (IRC R311, R311.2) 24. ❑ There shall be a floor or landing on each side of each exterior door, except where a stairway with 2 or fewer risers located on the exterior side of the door, other than the required egress door, a landing is not required for the exterior side of the door. The landing must be no lower than 73/ -inches below the top of the threshold of the door provided the door does not swing over the landing. (IRC R311) Documentl Page 3 of 11 25. ❑ Stairways must be at least 36 -inches in width. Handrails shall not project more than 4'h -inches. The maximum rise may not exceed 73/ -inches. The minimum tread depth may not be less than 10 -inches. Minimum headroom is 6 -feet, 8 -inches. For stairways with solid risers a nosing of 3/ -inch to 1'/ -inches shall be provided. When open risers are used the opening between the treads shall not allow the passage of a 4 -inch sphere to pass through. Landings must be provided at the top and bottom of the stairway that is the width of the stairway measuring at least 36 -inches in the direction of travel. Handrails shall be provided on at least one side of stairways with 4 or more risers and ramps with a slope exceeding 1:12. Handrails shall be mounted 34 -inches to 38 -inches above the nosing of the treads. Handrails must be continuous for the entire length of the stairs and provided with a minimum space of 1 %z -inch between the wall and the handrail. Ends shall be returned or terminate in newel posts or safety terminals. See the requirements and more information. (IRC R311.7.8.2) 26. ❑ Handrail grip size shall be: A Circular Handrails: 1'/ -inch to 2 -inches perimeter. B Non -Circular: 4 -inches to 6'/a -inches perimeter with a maximum cross section of 2'/ -inches. C Perimeter Dimension Greater than 6'/- inches: shall have a finger recess on both sides. 27. ❑ Guards must be provided for porches, screened porches, balconies, fixed seating and raised floor surfaces more than 30 -inches above the floor or grade below. Guards must have a minimum height of 36 -inches. Open sides of stairs with a total rise of more than 30 -inches above the floor or grade below shall have guards not less than 36 -inches high. Intermediate rails shall not allow the passage of a 4 -inch sphere. (R312) Window fall protection must be provided for window openings less than 24 inches above the finished floor and more than 72 inches above grade or surface below. (R312.2) Ceiling Heights 28.6eiling heights for habitable rooms, hallways, bathrooms, toilet rooms, laundry rooms, and basements shall be a minimum of y7 -feet measured from the finished floor to the lowest projection of the ceiling. Non -habitable basements may have a ceiling height of 6 -feet, 8 -inches with clearance below beams and ducts of 6 -feet, 4- inches. Bathroom may have a ceiling height of 6 -feet, 8 - inches at the fixture front clearance area and over the fixture. (IRC 8305.1) Roof Assemblies 29. ❑ Attic access must be provided for attics that exceed 30 square feet and that have a vertical height of 30- inches or greater. The access must be located in a hall or readily accessible location with a minimum 22 -inches x 30 -inches access opening. The access must provide a minimum of 30 -inches headroom. (IRC R807) 30. ❑ Enclosed attic and rafter spaces must have cross ventilation for each space through screened openings. The total net free ventilating area shall not be less than 1 per 150 of the area of the space ventilated. The area may be calculated at 1 per 300 provided that 40-50% of the total net ventilation openings is located not lower than 3 feet below the ridge, as high a possible with the balance located at the soffits or eaves. At least a 1 -inch space is required between the roof sheathing and the insulation at the location of the vent. (IRC R806) 31. ❑ Roofs decks and enclosed roofed areas must be provided with roof drains installed at the low point of each roof. Where roof drains are installed, overflow drains or scuppers are required. (IRC R903.4) Light and Ventilation 32. ❑ All habitable rooms shall be provided with aggregate glazing area for natural light of not less than 8% of the floor area of such rooms. The glazed areas need not be installed in rooms where section (M1507) is satisfied and artificial light is provided at an average of 6 foot-candles at a height of 30 inches. 33. ❑ Except for vehicular garage doors, at least one exterior light and a switch shall be installed at all outdoor entrances and exits with grade level access (2014 NEC 210.70(A)(2)(b). 34. ❑ All exterior and interior stairways shall be provided with artificial illumination including all treads and landings. Interior stairs shall be illuminated with lighting levels of not less than 1 foot-candle measured at the centerline of the treads and landings. Exterior stairways leading to a basement shall be provided with artificial illumination at the bottom landing of the stairway (IRC R303.7) Documentl Page 4 of 11 35. ❑ Natural ventilation shall be through windows, doors, louvers or other approved opening to the outdoor air. The minimum openable area to the outdoors shall be 4 percent of the floor area being ventilated. Glazing need not be openable where the opening is not required by section R310 and a whole house mechanical ventilation system is installed in accordance with M 1507. 36. Bathrooms, water closet compartments and similar rooms shall be provided with an aggregate glazing area of 3 square feet, one half of which must be openable except where artificial light local exhaust system are provided in accordance with M1507. OV2. Glazing and Window Requirements 37. ❑ Safety glazing shall be installed in the following hazardous locations and be permanently labeled as safety or tempered glazing (IRC R308): A Glazing panels in doors. B Glazing enclosing spas, bathtubs or showers. hinged shower doors shall open outward. (R308.4.5, P2708.1) C Glazing panels adjacent to and within 24 -inches of the edge of a door. D Glazing panels greater than 9 square feet within 18 -inches of the floor. E Glazing used for railings. F Glazing used for barriers for swimming pools and spas. G Glazing enclosing stairways, landings, and ramps within 36 -inches horizontally of a walking surface. 38. ❑ Skylights must be: (IRC R308.6 Table N1102.1) A Laminated glass (with restrictions) B Fully tempered glass (with retaining screen). C Skylight U -factor required U-0.45. D Skylights installed on roofs flatter than 3 units vertical to 12 units horizontal must be mounted on a curb 4 -inches above the roof. 39. �3athrooms, toilet compartments and similar rooms shall provide a minimum of 3 square feet of glazing. Half of which must be openable. Mechanical ventilation may be provided in lieu of the window. See mechanical requirements below. Wallboard Requirements 40. ❑ The garage shall be separated from the residence and its attic by materials of not less than 1/2 -inch gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5 8 -inch Type X gypsum board. Where the separation is a floor -ceiling assembly, the structure supporting the separation shall also be protected by not less than V2 -inch gypsum board. (IRC R302.6) Openings between the garage and residence shall be equipped with solid wood doors not less than 1 -inch in thickness, solid or honeycomb core steel doors not less than 1 -inch thick, or 20 -minute fire -rated doors. 41. ❑ Openings are prohibited between garages and rooms used for sleeping. (R302.5.1) Doors between attached garages and living space shall be weather stripped to the degree necessary to make them airtight and shall be self-closing and self -latching. 42. ❑ Enclosed accessible space under stairs shall have walls, under stair surface and any soffits protected on the enclosed side with %z -inch gypsum board (IRC R302.7). 43. ❑ Cement, fiber -cement, glass mat gypsum backer and fiber reinforced gypsum in compliance with ASTM C 1288, C 1325, CI 178, or C 1178 and installed in accordance with manufacturer recommendations shall be used as backers for wall tile in tub and showe areas and wall panels in shower areas. (IRC R702.4.2) 44. Nail spacing for gypsum board '/z gypsum board Ceiling 16 o.c., 7", nails 12", Type S screws 'h wall spacing 24" o.c., 8" nail spacing. 12" o.c. screws. 5/8 ceiling board 16" o.c., 7" nails 12" spacing, screws 24" o.c. 8". c��ry of DocumentlRic, Page 5 of 11 .4 � 45. 2r Water-resistant gypsum backing board used as the base or backer for adhesive application of ceramic tile or other required nonabsorbent finish material shall conform to ASTM C1396, C1178 or 01278. It is permitted on ceilings where framing spacing does not exceed 12 -inches o.c. for Y2 -inch thick or 16 -inches o.c. for 5 8 -inch thick gypsum board. Water-resistant gypsum board shall not be installed over a vapor retarder in a shower or tub compartment and may not be used where there will be direct exposure to water, or in areas of continuous high humidity. All cut and exposed edges shall be sealed. (IRC R702.3.8) 46. ❑ Floor assemblies, not required elsewhere in this code to be fire resistance rated, shall be provided with a %z -inch gypsum wall board membrane, 5/8 -inch wood structural panel membrane, or equivalent on the underside of the floor framing member. (IRC 501.3) Mechanical Requirements 47. ❑ Crawl spaces shall be provided with conditioned air in compliance with Section N1102.2.9. Crawl space walls shall be insulated in accordance with Table N1102.1 or Table N 1102.1.2. Crawl space wall insulation shall be permanently fastened to the wall and extend downward from the floor to the finish grade level and then vertically and/or horizontally for a least an additional 24 -inches. Exposed earth in unvented crawl space foundations shall be covered with a continuous Class I vapor retarder with a minimum thickness of 10 -mil. All joints of the vapor retarder shall overlap by 6 -inches and be sealed and taped. The edges of the vapor retarder shall extend at least 6 -inches up the stem wall and shall be attached to the stem wall. N1102.2.9.2.2 Ventilated crawlspaces. Ventilated crawlspaces shall be provided with insulation in accordance with Table N1102.1. 48. ❑ Habitable rooms must be provided with outdoor openings for ventilation equal to at least 4% of the floor area and shall have heating facilities capable of maintaining 68° at 3 -feet above the floor and 2 -feet from exterior walls The windows need not be openable in a room where an opening is not required to be an egress window and a mechanical ventilation system is capable of producing 0.35 air change per hour in that room, or a whole house mechanical ventilation system provides 15 cubic feet of outdoor air per minute. 49. Egfxcept where bathrooms, water closet compartments and other similar rooms are provided with windows with not less than 3 square feet of glazing, with an openable area of 1.5 square feet or greater, a mechanical exhaust fans shall be installed and exhaust directly to the exterior, capable of providing an exhaust capacity of 50 cfm intermittent or 20 cfin continuous exhaust. (IRC R303.3, M1507.4) 50. ❑ Dryer vents must be rigid metallic, independent of all other systems, shall terminate outside the building, be equipped with a back -draft damper, and sized and terminated per the manufacturer. The maximum length of the exhaust duct shall be 35 -feet (Unless approved under the manufacturer's listing) from the connection to the transition duct fiom the dryer to the outlet terminal. Where fittings are used, the maximum length of the exhaust duct shall be reduced in accordance with (IRC Table M1502.4.4.1) Flexible transition ducts are limited to 8 -feet, shall not be concealed within construction, and shall be listed and listed per UL 2158A. (IRC M1502) 51. ❑ Appliances and equipment shall be installed in accordance with the conditions of their listing. Manufacturer's installation instructions must be available at the time of the inspection. (IRC G2408.1, M1307.1, M1401.1, M1902.2) 52. ❑ Appliances shall be accessible for inspection, service, repair and replacement without removing permanent construction. 30 - inches of working depth and width shall be provided in front of the control side of an appliance. (IRC M 1305.1) 53. ❑ Gas and solid fuel appliances located in a garage and hazardous locations shall be elevated so the source of ignition is at least 18 -inches above the floor. Rooms and spaces that are communicate directly with the garage and are not part of the living space shall be considered as part of the garage. Appliances located in garages must be installed at least 6 -feet above the floor or protected from motor vehicle impact. (IRC G2408.2, G2408.3) 54. ❑ Combustion air is required for all liquid fuel, solid fuel and gas appliances. (IRC M1701.1, G2407) 55. ❑ Gas burning appliances may not be located in or obtain combustion air from: a sleeping room, bathroom, toilet room, or storage closet unless it is a direct vent appliance or installed in an enclosure that opens only into a bedroom or bathroom in and such enclosure is provided with a solid weather-stripped door, a self-closing device and all combustion air is taken from the outdoors. (IRC G2406.2) Documentl Page 6 of 11 56. ❑ B, BW, and L vents and factory -built chimneys must be provided with a clearance to combustibles per the manufacturer's listing. Where vents pass through insulated assemblies, they must be provided with an insulation shield. A clearance of 9 -inches is required between single wall vent connectors and combustibles. Gas vents must penetrate through the roof flashing, jack or thimble and terminate in a Chimneys listed cap or per the manufacturers listing. Decorative shrouds installed at terminations shall be listed and installed per the manufacturer. (IRC G2425, G2426, G2427) Masonry Fireplaces, Masonry Chimneys and Factory -Built Fire Places and Chimneys 57. ❑ Gas logs installed in solid fuel burning fireplaces shall be tested in accordance with ANSI Z21.60 and installed per the manufacturer's installation instructions. Gas logs installed in bedrooms must be direct vent or provided with an approved source of outside combustion air. The approved gas log set must be installed in the Solid -fuel burning appliances at the final inspection. (IRC G2406, G2432, and G2434) 58. ❑ Fireplace hearths shall be a minimum 4 -inches thick. Hearth extensions shall be a minimum of 2 -inches thick. (R1001.9.2) 59. ❑ Hearth Extensions, shall extend beyond the fire place opening a minimum of 16 -inches from the front opening and 8 -inches beyond the sides of the opening where the fireplace opening is 6 square feet or less. Fireplace openings greater than 6 -square feet shall extend a minimum of 20 -inches in front of the opening and 12 inches beyond the sides of the openings (R 1001.10) 60. ❑ All wood beams, joists, studs and other combustible materials shall maintain a minimum 2 -inch space on the sides and front of the masonry fireplace and 4 inches from the back faces of the fire place. Except to provide for fire blocking the air -space shall not be filled. (R1001.11) 61. ❑ Exposed combustible mantels or trim may be placed directly on the masonry fireplace front surrounding the fireplace opening providing such combustible materials are not placed within 6 -inches of the fireplace opening. Combustible materials placed within 12 -inches of the fireplace opening shall not project more than 1/8 -inch for each 1 -inch distance from such opening. (81001.11 exception No. 4) 62. ❑ Masonry chimneys shall extend a minimum of 24-inhces above any portion of a building with 10 -feet with a minimum of 36 - inches of the highest point where it passes through the roof. 63. ❑ Masonry chimneys shall have a concrete, metal or stone cap, sloped to shed water, a drip edge and a caulked bond break around any flue lines in accordance with ASTM C 1283. 64. ❑ Factory built fireplaces and chimneys shall be listed and installed in accordance with their listing. Factory built hearth extensions of approved factory -built fireplaces shall be installed in accordance with the fireplace listings. Electrical Requirements 65. ❑ All electrodes present at each structure shall be bonded together to form one grounding electrode system to include: Concrete Encased Electrodes (LIFER), water piping, ground rings, grounding rods, and plate electrodes. Bonding shall ensure electrical continuity. The electrode conductor must be connected in an approved manner and inspected prior to concealing. (IRC E3607, E3608, E3609, E3610, E3611) 66. ❑ All hot, neutral, and grounding conductors in electrical boxes shall be tied together with a mechanical connection at the time of rough inspection. 67. Q Recessed lighting fixtures must either be IC -rated or installed in a sealed box in which the insulation is at least 3 -inches from the light fixture. All recessed lights must be tightly sealed or gasketed to prevent air leakage through the fixture into the ceiling cavity. (IRC N1102.4.5) 68. E] Tamper -resistant Receptacle outlets are required in every kitchen, family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room or similar dwelling areas spaced so that no point along the wall line exceeds 6 -feet from an outlet. (IRC E3901, E3902, and 4002.1-4002.14) A Counters 12 -inches in width or wider shall have receptacles placed no more than 20 -inches above the counter top and spaced so no point exceeds 24 -inches from an outlet. B Island and peninsula counters with a length at least 24 -inches and a width of 12 -inches or greater must be equipped with at least one outlet. C At least one receptacle shall be installed in a bathroom within 36 -inches of each basin. CttV ^ L� Documentlf`��'�/� Page 7 of 11 D A least one receptacle outlet must be installed in each laundry, basement, attached garage and detached garage with power. E At least one receptacle outlet that is accessible while standing at grade level and located not more than6-feet, 6 -inches (1981 - mm) above grade, shall be installed outdoors at the front and back of each dwelling unit having direct access to grade. Balconies, decks, and porches that are accessible from inside of the dwelling unit and that have a usable area of 20 square feet. F Attics or crawlspaces containing equipment must be provided with at least one receptacle outlet within25-feet of the equipment. G Hallways 10 -feet or more in length. 69. ❑ Two 20 -amp rated branch circuits shall serve receptacles in the kitchen, pantry, breakfast area, and dining area. At least one 20 -amp branch circuit shall supply bathroom receptacles and at least one 20 -amp branch circuit shall supply laundry. (IRC E3703�, E3703.3, E3901) 70. ,vim, mound fault protection shall be provided on all 125 -volt, single phase, 15 and 20 -amp receptacles in the following locations: bathrooms, garages, unfmished grade level accessory buildings, at exterior locations, crawlspaces, unfmished basements, kitchen counters, within 6ft. of laundry, utility and wet bar sinks, boathouses, hydro massage, spa and hot tub locations. Receptacles must be in a readily accessible location. (IRCE3902, E3902.11) 71. ❑ Combination type Arc -Fault circuit interrupters must be installed on all 120 -volt 15 and 20 -amp branch circuit outlets in Receptacle outlets are required in every family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room, h llway, closets, and similar dwelling areas. (IRC 3902.12) 72. At least one wall switch -controlled lighting outlet shall be installed in every habitable room, bathroom, hallway, (1 Oft) stairway, attached garage, detached garage with electric power, and at the exterior side of each outdoor egress door having grade level access. Attics, under floor spaces, utility rooms and basements containing equipment or used for storage must be provided with a switch. 73. ❑ Balconies, decks, and porches that are attached to the dwelling unit and are accessible from inside the dwelling unit shall have at least one receptacle outlet accessible from the balcony, deck or porch. The receptacle outlet shall not be located more than 6 feet -6 inches above the balcony, deck or porch walking surface (2014 NEC 210.52(E)(3)). 74. 9-<mmoke alarms shall comply with UL 217. Smoke alarms are to be powered by the building's wiring operated light. (IRC E3903) with battery backup and shall be interconnected so the actuation of one alarm will activate all alarms in the dwelling unit. Smoke alarms shall be installed in the following locations: (IRC R314) A In each sleeping room. B Outside each sleeping area in the immediate vicinity of the bedrooms. C One on each additional story including basements. 75. Eltarbon Monoxide alarms are required in a single-family dwelling that has fuel -fired appliance(s), or a fireplace, or an attached garage. The alarm must be installed within 15 -feet of the entrance to each sleeping room. Must be listed by a nationally recognized, independent lab. Plugs into a dwelling's electrical outlet and has a battery backup. They may be combined with a smoke -detecting device if the combined device complies with applicable law. (IRC R315) 76. ❑ Clothes closet lighting shall be limited to surface -mounted or recessed incandescent fixtures with completely enclosed lamps, and surface -mounted or recessed fluorescent fixtures. Surface mounted fixtures shall be installed on the wall above the door or on the ceiling with the following clearances between the fixture and the nearest point of a storage space: (IRC E4003.12) A Incandescent fixtures or LED shall have a minimum 12 -inch clearance. B Recessed incandescent and fluorescent fixtures shall be installed in the wall or ceiling with a minimum 6 -inch clearance to the nearest point of storage. 77. ❑ Working space must be provided around energized equipment for servicing and maintenance. The minimum dimensions shall not be less than 36 -inches in depth and 30 -inches in width in front of the equipment. Working space shall extend to at least 6 -feet, 6 -inches above the floor. (IRC E3405.2) City Of Documentltc�I Ridgy dt Page 8 of 11 78. 2 Electrical fixtures installed in wet or damp locations shall be installed so that water cannot enter or accumulate n wiring compartments or other electrical parts. Fixtures installed in wet locations must be labeled "suitable for wet locations". Fixtures installed in damp locations must be labeled "suitable for damp locations" or "suitable for wet locations". Switches or circuit breakers located in wet locations or outdoors must be enclosed in a weatherproof enclosure. Outdoor receptacles must have a weatherproof enclosure and an in -use cover. Cord -connected fixtures, hanging fixtures, track lighting, pendants, and ceiling fans shall not be located within3-feet horizontally and 8 -feet vertically from the top of a tub or shower rim. (IRC E4003.9, E4002.8, E4002.9, (E4002.10, E4003.9, E4003.10, E4003.11) 79. ❑ Swimming pools, fountains, hot tubs, spas, and hydro -massage "Jacuzzi" tubs and similar installations shall comply with all provisions of the IRC Appendix G and Chapter 42 for the approval of bonding equipment and lighting. All 15 and 20 -amp, single- phase 125 -volt receptacles located within 20 -feet of the inside walls of pools, outdoor spas and hot tubs shall be protected by a GFCI receptacle. Motors and equipment must be accessible without damaging the building structure or building finish. (IRC E4202, E4203, EE4204, E4205, E4206) 80. ❑ The reinforcing shell of the pool shell, metal forming shells, coping stones, deck, brackets of niche fixtures, metal fittings, and electrical equipment, located less than 5 -feet horizontally and less than 12 -feet above maximum water level of swimming pools and built in place hot tubs shall be bonded together. The parts specified above shall be connected to an equipotential bonding grid. (IRC E4204.2) Plumbing Requirements 81. [g,15�v systems shall be tested on compellation of the rough piping installation by water or for piping system other than plastic by air with no evidence of leakage. Either test shall be applied to the drainage system in its entirety or in sections after rough piping has been installed. A Water test 10 feet above the highest fitting connection or to the highest point of the completed system. The system shall prove leak free for 15 minutes. B Air test shall maintain 51bs of pressure for 15 minutes. 82. t gl iping must be inspected and tested prior to concealing. It shall be protected against physical damage and it must be approved for use and bear the identification of the manufacturer. (IRC P2503, P2603, P2608.1) 83. ❑ Bathtubs, walls above bathtubs with shower heads, shower floors, and shower compartments shall be finished with a non- absorbent surface which extends to a height not less than 6' above the floor. Showers must have a minimum 900 square inches of interior area and a minimum dimension in each direction of 30 -inches. 84. ❑ Shower valves must be pressure balance/thermostatic mixing valves. Shower receptors shall have a curb threshold not less than I -inch below the sides and back of the receptor. The curb shall measure a minimum of 2 -inches to a maximum. of 9 -inches above the top of the drain. (IRC R307, P2708, P2709) 85. ❑ The centerline of toilets or bidets shall not be less than 15 -inches from adjacent walls or tub. Toilets, bidets, and lavatories must have a minimum clear space of 21 -inches in front of the fixture. Lavatories require a 4 -inch clearance to wall or to a toilet. (IRC P2705) 86. ❑ Showers and tub/shower combinations shall have control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with high limit stop per ASSE 1016 or CSAB125.1. Tubs shall also have a control valve as listed for a shower or a water -temperature -limiting device that conforms to ASSE 1070. The high limit stop for a device shall be set to a maximum of 120°. (IRC P2708.3, P2713.3) 87. ❑ Backflow prevention must be provided to prevent contamination of potable water. This includes but is not limited to: hose connections, irrigation systems, boilers, solar systems, fire sprinklers, and dishwashers. Backflow device must be inspected and approved by a 3rd party agency. (IRCP2902.2, Table P2902.3, P2717) Energy Efficiency 88. ❑ Insulation A Walls R-20; Ceiling R-49; Crawlspace R-19; Floor R-30. City of 89. F-1Fenestration wt Ridge Documentl �u;; Page 9 of 11 A Windows shall maintain a maximum U -Factor of 0.32 90. ❑ Supply Ducts in attics shall be insulated to a minimum of R-8. All other ducts shall be insulated to minimum R-6. (NI 103.2. 1) 91. ❑ Combustible insulation shall be separated a minimum of 3 -inches from fan motors and heat -producing devices. Insulation shields must be provided where vents pass thorough insulated assemblies and must terminate at least 2 -inches above attic insulation materials. Can lights must be airtight if located in the building envelope. (G2426.4) A Class I or II vapor retarders are required on the interior side of the insulation in framed walls, floors and roof/ceilings of the build'ing's thermal envelope. The vapor barrier is not required in construction where moisture or freezing will not damage the materials, or where the framed cavity (or space) is ventilated to allow moisture to escape. A vapor retarder is not recommended on a concrete basement foundation wall or in a shower /bath compartment (IRC 702.7, R702.7.1). Building Inspection Requirements, Permit Expiration and Permit Extensions 92. ® It is the responsibility of the applicant, contractor, owner or owner's agent to schedule the required building inspections. Building inspections requested before 12:00 midnight will be scheduled the following business day. Building inspections not ready for inspection, or missed inspections conducted on the scheduled date, may be subject to a $60.00 re -inspection fee. Building inspections maybe requested on-line athttps://www.ei.wheatridpe.c us/281/Buildin-Inspections or by calling (303) 234-5933. 93. ® Except when there is an outstanding balance due to the city, the Building Department does not cancel inspections (including due to inclement weather). It is the responsibility of the applicant, contractor, owner or owner's agent to cancel the scheduled building inspections, prior to 8:00 am, the date the inspections are scheduled. Failure of the applicant, contractor, owner or owner's agent to cancel inspections prior to 8:00 am on the date of the inspection is scheduled may be subject to a re -inspection fee of $60.00. maybe cancelled on-line at https://www.ci.wheatridize.co.us/281Building-Inspections and scrolling down or by calling (303) 234-5933 94. ® Original job cards and permits shall be posted and shall be accessible to the Building Inspector at the site at all times. Copies of job cards or permits will not be accepted. Lost job cards and permits are subject to a $25.00 administrative fee to reprint the job card and/or permit. 95. ® Original, city stamped, approved plans are required to be kept at the job site at all times. Copies of approved plans will not be accepted. The approved job site plans shall not be written on or altered in anyway. Altering an approved set of plans is grounds for voiding of the approved plans. Approved plans not available during inspections are subject to a re -inspection fee of $60.00 and must be rescheduled for another day. 96. ® Changes in the scope of the project may warrant revisions to the approved plans and shall first be submitted to and approved by the Building Department prior to making any changes in the field. Approved revised plans shall be kept on the jobsite and made available during all inspections. Prior to making any changes, discuss the changes of the scope covered under the permit with the Building Inspector. 97. ® Buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. (IRC 319) 98. ' All dwellings shall have a controlled method of water dispersal fiom roofs that will collect and discharge all roof drainage at least 5 -feet from the foundation. Gutters, downspouts, downspout extensions shall be deemed adequate to meet these requirements. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6 -inches within the first 10 -feet. (IRC R401.3 and 8801.3) 99. ® Prior to Building Final inspection all outstanding balances due to the city of Wheat Ridge shall be paid. This includes re- inspection fees, plan check fees, permit fees, plan revision fees, etc. I OpOft-Prior to the Final Building Inspection, a Zoning Final Inspection is required for new construction, additions, detached structures, \ �( patio covers and decks or alterations to the existing exterior of the structure. Retrofitting of windows, painting, replacing of siding, 1� 1 re -roofs, or new or altered solar panel installations does not require a Zoning Inspection. The Planning and Zoning Department N do not guarantee next day inspections. Contact Planning and Zoning to schedule a Final Zoning Inspection at (303) . 14/04Prior to Final Building Inspection, a Public Works Final Inspection is required for new construction and/or additions which �I increase the building footprint of the existing structure or alteration of the existing drainage pattern of the site or addition of any 1 slab work which alter the existing drainage pattern of the site. Contact Public Works at (303) of Documentl Page 10 of 11 VVheat Ridge guildiog Divison The city of Wheat Ridge does not issue Temporary Certificate of Occupancies (TCO's). All inspections must be completed L and all required departments and/or required outside agencies must be signed off prior to the issuance of a Certificate of Occupancy. ` 103. ® Approval of this permit shall expire one year from the date of the issuance of the permit. Request for extensions for up to 180 days must be made in writing to the Building Official at least two weeks prior to the expiration date. Written request for extension must show reasonable justification to grant the extension and does not guarantee approval. Failure to request the extension prior to the expiration date will result in an expired permit. Expired permits are subject to the resubmission of all plans, documents and payment of all new permit and plan review fees. Plans approved under previously adopted codes may be subject to the requirements of the current adopted codes. , Plans Examiner dschultz@ci.wheatridge.co.us 7500 W. 29th Ave. Wheat Ridge, Co 80033-8001 (303) 235-2892 City of Documentl Wheat r +d� 1 Page 11 of 11 ilding WEST METRO FIRE PROTECTION DISTRICT Contact the appropriate jurisdiction for additional requirements Jefferson County: 303-271-8260 I Edgewater: 303-235-8300 Douglas County: 303-660-7497 Morrison: 303-697-8749 Lakewood: 303-987-7500 I Mountain View: 303-421-7282 Wheat Ridge: 303-234.5900 ; Lakeside: 303-455-1980 t S -r1 �4 G BA-rN Rcso KA UTILITY Ct..OSEE " E5' 6 our' Ltr L-16NT wAtee. Llr�ts """' 6�ansrr)Y�nT LA NC S In LI, N 9 pzaposeD 3An4RaoM �i WEST METRO FIRE PROTECTION DISTRICT New Building I Core/Shell I Tenant Improvement FIRE DEPARTMENT PERMIT NOT REQUIRED_ The following fire protection system(s) are required: ❑ Fire Alarm System ❑ Fire Suppression/Sprinkler System ❑ Other: Plans shall be submitted and permit(s) obtained for any required systems marked above. ALL WORK SHALL ADHERE TO THE 2012 IFC AS AMENDED BY WEST METRO FIRE RESCUE Additional components or changes my be required upon field inspection and prior to final of any/all systems. DATE: 311/2018 PLAN REVIEWER: kbrooks "-k°IIKe \ fk P C'?&e •}o tt (,.,t (,A I'+n, wall 64wtev) C) ot& o%VJ 64"F09-1 wt will "M me O} let- A rtiftin ,-hl�t+ c dwusf+e •¢w+air+ in Sarre%Currcr\4 loco( ''On . Mit Vcofow �* Mout 5inK 4t, c1a�t"4 wo. I k ) 04a +tc 00- ex i--FInWOW) . A118V"-N+ r i vw5 . 5 - Sprinkler system should be in the basement only. If existing conditions are otherwise, notify the Fire District. - All work shall comply with the 2012 International Fire Code. q' (CSU w y A-p-e.tiue Ct cj3c. �-d v 3 U koposc D BAM41R 60" E)(%S7'INCr 8�}1Rca+�M '51 UTE OTY CUOSE'r S, i ovr Ltr LI bt47 s"Irc %A Nacetz Lints uNc S q, ,4 l2I Date � obr a a n,a Pe"m �ooD."'��,,�1 o�j,,,.0es tpNmafor. ,o cw MePoem 1!'+'4 code w Mem ,.,we .1 own nco pew I. t,cily • k!f PIW- Pjdge YaWity.arl rxr�mit whear APPROVED Rid for coat CMp"m The l � , issuance of o permit w opprovof of pons specifications adaompulotions shot/ not be a permit for, w an approval of any viobtion to AV Of the ptovlsi— of the bWldinp code Oral any City ordinances. permits DrewminY to give ovthwXy to violote ol=bl the prov8kns of the BWldmp cottrs w otherOrtf»axes al the Gy slgAnot 6e vdid &9 k f \^/f- p c'Qac iv, ft move 0%1'ihna vwl( 64 wZtn ejQ% 4` agvu: �sQ"Iroowwl •J We wt li ovve not o,+tct A o)t i1! (trod one. S. Doom remiv► )+bjttF c Oras+e- CtW4In in same/cur,rcrrk loccc�lon . We vcbfose Im MOVE s1nK' 40 wail )0AI ite 00, ex15+lnQ wWsk and M Ci' to D Q INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request n inspection before MIDNIGHT (11:59 PM) to receive ainspection the following business PERMIT: l� ADDRESS: l(J hl� `�JOB CODE. 5 � g qylv4v-o Mv-kl -V, -7 v Q -T Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground 2 Fk Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 2 Fk 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS �� F, PERMIT:4ADDRESS: QW JD I,J � l A-VQOB CODE:Izze YrZ Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. // i CITY OF WHEAT RIDGE Building Inspection, Division (303) 234-5933 Inspection line __1�9�(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L) o q - na Job Address: (o !'o _5--D W L) a '/-h A ,,e Permit Number: --c) O /-7 G cl S 3 B V 1 ,t ❑ No one available for inspection: Time = 3) AI PM Re -Inspection required: Yes Na When corrections have been made, call for re -inspection at 303-234-5933 Date: 1 Inspector: -7-b DO NOT REMOVE THIS NOTICE im i CITY OF WHEAT RIDGE � Building Inspection Division (303) 234-5933 Inspection line �(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: cl �� Job Address: to b S'c t -i `/ Permit Number: a 0 r -7 0 `t S 3 YNct iV oA*pr,r,o� e d U0 c,,_/,_le I i' L Car Cv O l Pq ,r.2 ►BSc v t� ❑ No one available for inspection: Time62'= 3lo AM PM Re -Inspection required: es No When corrections have been made, call for re -inspection at 303-234-5933 Date: ! / 6 1 S' Inspector: DO NOT REMOVE THIS NOTICE 0V i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax Inspection Type: INSPECTION NOTICE LIC .7- � a Job Address: (v S' --o w 4-14-1 f4 4,e Permit Number: o -7 o z7 5- 3 o n ca. f" o -�- -1 a (J 6`E7 v-,-- Mid- -2 - M i aI?C 4PSPm­p ❑ No one available for inspection: Time = g 19PM Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303 -234 - Date: ► / S Inspector: —7-t) DO NOT REMOVE THIS NOTICE City of Wheat Ridge t., . Commercial Roofing PERMIT - 201709563 n PERMIT NO: 201709563 ISSUED: 12/13/2017 JOB ADDRESS: 6650 W 44th AVE EXPIRES: 12/13/2018 JOB DESCRIPTION: Remove and replace roofing material with metal roofing; 34.70 squares *** CONTACTS *** OWNER (303)882-6169 CRACK AND NEEDLES LLC SUB (720)262-8060 Joan Mahan 170305 Exterior Guru *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: 520 / Office; 0 USE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 25,920.00 FEES Total Valuation 0.00 Use Tax 544.32 Permit Fee 453.55 ** TOTAL ** 997.87 *** COMMENTS *** *** CONDITIONS *** In order to pass a final inspection on commercial elastomeric or similar type roofing, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and Mid -roof inspections may be called in at the same time, 100 percent of the sheathing must be complete and 25-75 percent of the midroof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. City of Wheat Ridge . Commercial Roofing PERMIT - 201709563 PERMIT NO: 201709563 ISSUED: 12/13/2017 JOB ADDRESS: 6650 W 44th AVE EXPIRES: 12/13/2018 JOB DESCRIPTION: Remove and replace roofing material with metal roofing; 34.70 squares I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed* nd that all work to be Verfonned is disclosed in this document andlor its' accompanying approved plans and specifications. nofj r'e of OWNER! -or CONTR__A.C_=ormation ircle one) Date TIfis permit was issuedbased-un e inch provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of toes jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of �Wheat I ,oge MUNI`TY DEVELOPMEN-r Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits@ci.wheatridge.co.us FOR OFFICE USE ONLY Date: (a� Plan/Permit # Qo) � 0 Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: �0 4Li+�"' Ayt Property Owner (please print): OxcC a' N QLCuR S L -L C. Phone: (3036 Property Owner Email: i 4 Mailing Address: (if different than property address) Address: City, State, Zip: ummmyl_ Arch itect/E ng 1 neer E-mail: Phone: Contractor: E1CWi or au u_ UL Contractors City License #: " 11b*405' Phone: (:1211 woa -mob o Contractor E-mail Address: I For Plan Review Questions & Comments (please print): CONTACT NAME (please print): midq fthAOn Phone: 1-3 CONTACT EMAIL(please print): Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # City License # Plumbing: W.R. City License # Other City Licensed Sub: Mechanical: W.R. City License # Complete all information on BOTH sides of this form COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE WCOMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.)'( Sq. Ft./LF Amps Btu's Gallons Squares 3 ff. 4'D Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or AUTHORIZED REPRESENTATIVE of (OWNER) (CONTRACTOR Signature (first and last name): iy,tAJ2[;" /vl.Q(.Q/� A/%� DATE: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ 4 � m m O ro N q M N u m u OC) m O m ti •• m m m .4 N o 0 ro b1 0 N a 0 U Z!1 m i to ro d o U 0.j m o A O ro 0) 4-)0 u rA O ro U rt V o 00 0� A b o x w P4 a m 4-) to � V/ W o ro v 4+ U-) ►� q 0a a mu O H ��w �c p �O m m U 0 O U L u x .Q m z41 .c; 8 PO q /nll 3 u a o ti r. it V. 4) U 44 0 N ° O ZmLf) O �+ ° •• u1 o H J-1 u to 41 ro °U A 0 w i �i V ro r•� V 0 a ro o r1 �� d Cv a� jj m 0 WIDm Ln x 41EQ 0 ro w a o b a W 0 UOD l0 a� 4J U .� U A 11 .0 O CD m0 u m ° O z 0 O b m$ .m1 413 H a R4.) c -i O h 'N w° L1 0 mq N N U N A > ° � `� fA o W w 11 10.1 0 rd 44O m E R A rn o W A •ri w a 0 qq R � .g O .� � U 41b it 'ri M q m m V }� a �k a x .+�i U w w W C 0 1) tp7 �4 �@ m b a ���.. ww pub� H rromm N U O 0 U a4y F U w a 0 o 5 � qAM i CITY OF WHEAT RIDGE V, Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: OL-) Job Address: G65,C) W WITH AVE Permit Number: zo)-)()DL2SL ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes to When corrections have been made, call for re -inspection at 303-234-5933 Date: -3 11 1 r _ Inspectors ) DO NOT REMOVE THIS NOTICE ♦ .. . CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office " (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type 13 4-.?- Job Address ,A1 Permit Number .! AA— &-v£o f mid swa . A f !rgt s r f i�dDA� � °fJl3vL23& /aRw"96-ynie,4.P E.yrr£'f i2;E7 X29' - 33 6s -9 ,E v` ❑ No one avairaore ror inbpu�u >,,. !PM Re- Inspection required: Yes No When corrections have been made, call for inspection at 303 - 234 -5933 Date: 5//74x' Inspector >_ & � DO NOT REMOVE THIS NOTICE City of Wheat Ridge - - ~ Commercial Electric PERMIT - 080751 PERMIT NO: 080751 . ISSUED: 07/03/2008 JOB ADDRESSi 6650W 44TH AVE EXPIRES: 12/30/2008 DESCRZPTION: Hook.up phone cabinet 100 amp 120/240 volt meter CONTACTS owner 303/784-0369 Qwest . gc303/678-8389 Jeff McKusker 02-1634 McKusker Electric Inc. PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION: 0404 BLOCK/LOT# : 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 1,000.00 FEES Permit Fee 50.40 . Total Valuation .00 Use Tax 18.00 TOTAL . 68.40 . Conditions: Must comply w/ 2003 IBC & 2005 NEC. inereby czstiiy t.lxat the setbadcdistan.ccs prepos?d by "_his permie 3oolicac:on a,.e accurate, and do not violate applicable ordinances, rules or regulations of the City of wheat Ridge or covenants, easements or restrictions of record; that all measurements. shown, and al3egationsmade are accurate; that Ihave read and agree to abide by all conditions printed on this' application and that I assume full responsibility for compliance with the wheat Ridge Huilding Code (I.B.C) and all other ' applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. . Signature of contractor/owner date L This permit was issued in accordance with the provisiona set £orth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of t5e City. . . . 2. This permit shall espire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. . 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year.If changes have been or if suspension or abandonment exceeds one (1) year, £ull fees shall be paid for a new permit. . 4. Nowork of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall hotify the Building Inspector twenty-four.(24) hours.in advance for.all~.inspections and shall receive written approval on inspection card before proceeding with successive phasesof the job. 6. The issuance of a pezmit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violati n of the provisions of the building codes or any other ordinance, law, rule or regulation. . All plan review is ub c o field inspections. . Signature of Chief B di official date INSPECTION REQ EST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BEMADE BY 3PMANY.BUSINESS DAY FOR.INSPECTION THE FOLLOWING BUSINESS DAY. ~4 . . . . . . . . . . . . . . . . . . . . . . ■ ~ ~ ~ ~ ~ ~ ~ ~ - OccupancVti Ype ~ '1INSPECrioN LiNE: (303) 234-5933 TJ Inspections will not be made unless this card is posted on the buitding site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN SPACES PERTAINWG TO THIS irvarc~ivn FOUNDATION INSPECTIONS DATE COMMENTS: INinn~s . Footings/Caissons . . Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines . WaterService Lines CONCRETE SLAB FLOOR Electrical (Underground) Heating (U - Uu rvUi rwrt rw..-. -r....,. ROUGHS Sheathing . Lath / W aii tie ~ ~ Mid-Roof Electrical Service Rough Electric Rough Plumbing Gas Piping ~ Rough Mechanical e . _uon oaIna i0 PR[1CEEDMG _ Framing Insulation Drywall Screw FINALS Electrical )i Plumbing Mechanical Roof Building Final - Fire Department R.O.W & Drainage START ALL ROUTING ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking 8 Landscaping - - "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANN/NG AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFlCATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION 6Y THE BUILDING DIVISION DOES NOi CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCWPANCY. I M A .ir~v ~e 11cei iGn OCCUPANCY NOT PERMITTED UNTIL l,tKHrwHic vr vCwFAN,,~ PROTEGT THIS CARD FROM THE WEATHER ♦~~4' CITY OF WHEAT RIDGE ~ Building Inspection Division ~ (303) 234-59331nspection line . ~ l (303) 235-2855 Office '(303) 235-2857 Far INSPECTION NOTICE Inspection Type: &061.11c'SP. i Job Address/Permit Number: ~o cv• 0~1111,4~k' cc4sEl•zd~lS' . -„N ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes <~N~- "When corrections have been made, call for re-inspection at 303-234-5933 Date: 1 08 inspector7 Z~ DO NOT REMOVE TH/S NOT/CE , r .~~i CITY OF WHEAT RIDGE Building Inspection Division ~ (303) 234-5933 Inspection line (303) 235-2855 Office ` (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: ,lSLDG-J~Sd% 12SQ ~F~ Job Address/Permit Number: e:5;6&o zv, !/f`~0 Gcc,or✓~~v.lES ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes <0 'When corrections have 6een made, call for re-inspection at 303-234-5933 Date: 61117leSI Inspector: z L DO NOT REMOVE THIS NOTICE ~ , . . . ; ~ - n ~ _ . . / Y r i i A ~ CITY OF WHEAT RIDGE Building Inspection Division ~ (303) 234-5933 Inspection line . (303) 235-2855 Office ' (303) 235-2857 Fax - WSPECTION NOTICE Inspection Type: Job Address/Permit Number: ~6 ~ U• 5~• 7YI- A v~ ❑ No one available for inspect~-_<['i,1ne _ AM/PM Re-Inspection required: Yes No' ~When corrections have 6een mad all or inspection at 303-234-5933 ~I I Date: f/ O Inspector: ~ .IlA 11/AT OCIIiIAI/C T C 1~l/1TI/`C . City of Wheat Ridge Commercial Electric PERMIT - 080751 PERMIT NO: 080751 ISSUED: 07/03/2008 JOB ADDRESS: 6650 W 44TH AVE EXPIRES: 12/30/2008 DESCRIPTION: Hook up phone cabinet 100 amp 120/240 volt meter CONTACTS . . owner 303/784-0369 Qwest gc 303/678-8389 Jeff McKusker 02-1634 McKUSker Electric Inc. PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION: 0404 BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: . 1,000.00 FEES Permit Fee 50.40 Total Valuation .00 Use Tax 18.00 . TOTAL 68.40 Conditions: Must comply w/ 2003 IBC & 2005 NEC. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the wheat Aidge Building Code (I.B.C) and all other appl' b1e a Ridge Ordinances, for workunder this pesmit. Plans subject to field inspection. 7 P- Sig t of contractor/owner date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws.of the State of Colorado and to the Zoning Re9ulations and Huilding Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to espiration date. An extension may be granted at the discretion of the Building.official. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, prwided no changes have been or will be made in the ori9inal plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonmen[ exceeds one (1) year, full fees shall be paid for a new permit. n. No work of any manner shallbe done that will change the natural flow of water causing a drainage problem. 5. Contractor shall mtify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases.of the job. 6. The issuance of a pesmit or the approval of drawings and specifications sha11 not be constxued to be a permit for, nor an apprwal of, any violatio the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is sydfpe~f„~eld inspectione. Signature of Chief aate INSPECTION REQUEST LINE: (303)234-5933 BUILDINGOFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION TAE FOLLOWINGBUSINESS DAY. COMMUNITy DEVELOPMENT DEPARTMEiVT Building Pea¢it Number: ~ gd 7~ I ~ o BiJILDAG IICSPECTiON I,INE _ 303-234-5933 Date: CITY OF NHLAT RIDGE 7500 WESI' 29TH AVENUE ceL~~ R'HEAT RIDGE, CO 80215 -(303-235 Y~SSS~) _ ~Pdrd{cF3TdO!• Praperty Owner CQ w e S i' rroperty naares5: 66so• 5 `~"~T~~ i4u~ Phone:3~3~8yo36y Conhactor License No.: 3`j O Wh'ER20X1'RACfOA SIQiATURE OF i71VDIIt57MV QGG A31'D AGHEEWNf Phone- maae ae sswmals: thu 1 have xeaa xna'•-•v••• `~amown.maallcy~cw~t applica6~ md tfiat I assume tall a~ ro abide by atl condi6ons prmted m tbis mpws+bifitY for wmylian« .vim rhe wnat xia &nldmg Cude (U.B.C) and all othaapplicaLie Whu[ Ridge Ordimnccs, fw work wdv ~y~t cOWNERxcoxrnACroxzsMNm DESCRiP1TOlh: Pao/C up .~/Pk2eN~ e~c~i,'v~~e,Y" From Al~~n/ ~-c✓v~c~ T N .S T ij /VY' w' V "tr fG-L 1 $m ' BUII.DMG DEPARTMENT USE OAZY ZONIN6 CO!lNQNTS. AppIOY21_ T01IIlitg: BUItDING COYYEM9. - APPmva1: SIC: Sq_FL: 91 Puaejc Wowcs CorrE"rs_ Appaoval: DcatzPancY= Walls: Roof: Staaies: Residrntial Uaits. . Electrical License No: 3Plumbing I.icense No: Mechanical License No: ~mP~Y"/i7~~~$~.[~-CLrLT"C -z,L',,~COIRF/3Ry: Companr ERp'r'h°n Daie= Exp"snfion Date: Approval- Ap~~~ ~p~tioa Date: Approval: . ~ «>----~P~ntwuusoedmaro~ncewi8i~epmvsonszatm~L'mymcapptiapmandss mthebwsotthe~tcofCo7orMOandbi6e acaa.ums~maBml~gcodc,rwencRidge,co~«,mm+or,~~uk~~ c~.. ~s-- (2) ~ Tt- ~ ~otizom~YS ~anmhm~rdumtm~mrsa+~LmssurC~a+nr.omi~em1ee(B) mrbivimnsawnmvsais>u~yewieac. (7) Ifih'sPmmidaDaryavcwpemicmrybcaaqumdCocafteMamehvl'Ncemo~tm~ly~.~ym *z-'9'n1PlmsmdW=KG0d==d an!'~mm-`-•. -LuaotocadadmeP)Yca.IfetraagesLave~ Lavebemorw~Lbemadcin Noso*k of~l)YnSf]/frasLa116eyadfarattwp~ ~omaLaudm[ (A couaxmr~zbnteamcamaM cn.ugememmNEoworwatco,,zg.&.OOWnbu~ °OR[T~g~s~m.t~ueotr-~C~a)Lomsmaav,umf~anmmyau~smasnan nsdvc.w;am,ppovd ou iOycu~ cva nvmc 1Lcissvwccofa~~ofPocjob. (6) prorisionsaff6e ~~ortffiappfonl~'drs°'mS~~~sLallmtDeoonStroWbbeapurmtfa,narauaPR~~mY~iol~uonot~he ~8 ~da m mY otDcwmmtte. faw. mle onegdatioa CoastrucUOn Value:$ I,0601bD Pemut Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ CRe{$UStdiIIg IDSuCCtOI ~ ~ DRNE p z,¢uo ¢ Ka O 1~ il~ I Q ~x a °ar ~Om NmZ~ N N~ ~W { ` ~ii =ar-~ n aa inZ-nv d 0ao i"o~~ Q ~ ~ O t=il QS3~ N KTi O~pW~ S W O O~~z w a p{^ ~ o~~3 m ao ~wW0 UZaW * ~2 ~ ~ ol o D~ ~w m I 5 ~a il ~ - ' I z~ I w mre Q i F.._......._.._...~........ ~ k~ _ ~ ~ oc~ ~ --------'.6 ~ f i-----~ l. ~ I I S6 y VO ~p F W ~ILL mm I ! 0Z Q n O a ~ ~ I W p ~ W 00M ~1 I ~ZZW O NZ ~Z0 N/ ~ ~ m ~ v»p N w> ~~i+1N~~ Z Z O} ¢U ~a ~W~ ' ~ ~RIVE I ~ ~ a 4 QFW Z Q~ ~WOUZ ~ a 3 I ~ R~C'p Z >d' J~~Z a s = d S$1 ~ O 1- ~ W p W ZrzI- 3 Z pOul V OT OZaV O wm3 ~ a~ ow~ ~ w 3 ~ i ~U Q Z i ' i ~ ~ i z 0 ~ U ~o o s +o LEGEND 7RaNSFORNER D4 GAS VALVE ~ OWEST PfDfSTAL S SnCh ~ 10 [C ~ QWEST CROSS BO% D4 V10.7ER VALVE :CY CATY PEDESTAL 1; x. GEf- BURIED ELfG7RIC - FlRE HYORPNT O $PRINKIER HEAD e OEGIOUOUS iREE W/ CALIPER SIZE 1]EO S. Bellair. SY., O CO 80322 Sle. 185 w- BURIE~ WA7ER - K ~ EVERCREEN iREE W/ GALIPER SRE eewr, ~j VTILITY POIE PONER PEO E%ISTING PROPERTY IINE OR ROAD R.O.W. LINE po» Q : S"r OTR' SECiION:.$YL2~_ GLLI: ~VAOA FTfN SITE: 4397 NEwlANO CORPORA710N T~~SHIP: T35 GE0 CODE, 273110 O0.TE: PPRiI 14 2008 $DI CALFORNN SI, SIE 51 OO RANCE; R69'M qTY: PSM .bBp: R7502 DRNN BY: A.R.S. 6ENUER CO 80202 C.P.D. NO.: 822271EI CAUHTY: JEFFERSON ACAD FILf: R7502.awa ~ U ~ ~ DEPARTMENT OF PLANNING AND DEVELOPMENT 4 BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number Date 9522 9/23/99 Property Owner: Properry Address : 6650 W 44TH AVE Contractor License No. : 20476 Company : True Grit Construction Phone: 420-9622 Phone: 940-9574 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certiy that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restridions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) Construction Value : $2,125.00 Permit Fee : $83.25 Plan Review Fee : $0.00 Use Tax : $31.88 Total: $115.13 Use: Description : Tear off 1 layer recover with 25 year dimensional shingles Electrical License No : Company: Plumbing License No : Company : Mechanical License No : Company : Expiration Date : Expiration Date : Expiration Date : Approval: Approvai: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur applica6on and is subjec[ to the laws of the State oF Coloredo and to the Zoning Regulations and Building Code of Whea[ Ridge, Colorado or any other applicable ordinances of the City. (2) Th is permit shall ezpire if (A) the work authonzed is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abantloned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the ori9inal plans and specifcations and any suspension or abandonment has not exceeded one (7) year. If changes are made or if suspension or abantlonment ezceeds one (i) year, full fees shall be paid for a new permit. (4) No work of any manner shall be tlone that will change the natural Bow of water causing a dreinage problem. (5) Contrector shall no[ify the Building Inspec[or twenty-four (24) hours in atlvance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) The issuance of a permit or the approval of drewings antl speciFlCations shaaa111hhhnot he consWetl to be a permit for, nor an approval of, any violation of the provisions n of the building wdes or any other ortlinance, law, rule or regulatlon. . ~ t ~r ~ ~ / Chibf 13uildi Inspector DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : - BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 qPpLICATIo N Property Owner. G` R IPK~rc(~o Property Address : fobso W 41TK flVc Contractor License No. : 2-04 ILO Phone:'b3 -4'20 _.9t iZ- Company :-rr*r (,2J (1,.sPhone : 3eJ s_ 94o- S' J~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : a-i a-Qo(') I hereby certify that the setback distances proposed by this permit application are aecurate, and do not violate applicable ordinances, rules or regulations of the Ciry of INheat Ridge or covenants, easements or restrietions of rewrd: that all measurements shown, and allegations made are accurate; that 1 have read and agree to abide by ali conditions printed on this application, and that I assume full res nsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Vilpeatilpidge ordinances, forwork underthi; pertnit. (OWNER)(CONTRACTOR) Permit Fee : Use Tax: Total : use: Description :Ov7F CV_, ~~,11P.L L344,,~ 04~' Lfe)~*6r-- a7,Kqw,S, BUILDING DEPARTMENT USE ONLY SIC: Sq. Ft.: Approval : Zoning : G [1 o m-----' . Approval: s. m Approvai: Occupancy : Wails : Roof : Stories : Residential Units : Electrical License No : Company : Plumbing License No : Company: Mechanical License No : Company: Expiration Date : Approval : Expiration Date : Approval: Expiratioh Date : Approval : (1) This permit was issuetl in accortlance vnih the provisions set forth in yopur applicatlon antl is subjeet ta the laws of the State of Coloratlo and to the Zonin9 RegulaUOns and Builtling Code of Whea[ Ridge. Colo2tlo ar any oNer applipble ortfinances of the Ciry. (2) This pertnk shall expire if (A) the work authonzetl is not commenceO wifhin siaty (60) tlays from issue date ar (B) the building authonzed is suspenAed or abandonetl for a penotl of 120 tlays. (3) If Nis pertnit expires, a new pertnit may be acquired for a fee of one-half the amount nortnally required, provitletl no changes have been or will 6e made in the original plans antl specifiptlons antl any suspension or abantlonmen[ has not eacceedetl one (7) year. If dianges are made or if suspensian or abantlonment eXCeetls one (1) year, Tull fees shall be paitl lor a new pertnit (a) No work of any manner shall be Eone that will change the natu2l fiow of water pusing a drainage problem. (5) ConVactor shall no6fy the Building inspector hvenry-Pour (24) hours in atlvance for all inspections antl shall receive written approval on inspection prtl be(are proceetliing with successive phases of the . (6) The issuance of a pertnit or Ne approval ofjobdrawings and specificatlons shall not be consWetl to be a pefmit for, nor an approval of, any violation of the pmvisians of the builtling cotles ar arry other ortlinance, law, rule or regulatlon. Chief Building Inspector