Loading...
HomeMy WebLinkAbout9205 W. 44th AvenueCity of Wheatj�idge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033 -8001 P: 303.235.2846 F: 303.235.2857 June 26, 2013 OFFICIAL ADDRESS CORRECTION NOTIFICATION is hereby given that the following address has been assigned to the property /properties as indicated below: PROPERTY OWNER(S): Gary Lee Br Lan OLD ADDRESS: 9205 W. 44"' Ave., Wheat Ride CO 80033 NEW ADDRESS: 9205 W 44"' Ave., Unit A, Wheat Ridge CO 80033 (front unit) 9205 W 44"' Ave., Unit B, Wheat Ridge CO 80033 (back unit) SUBDIVISION: Juchem Garden Place LOT(s): KEY: 000 SECTION: 22 PARCEL NO: 39- 222 -07 -011 NOTES: This is a courtesy notification. AUTHORIZED BY: < DATE: 6— Z 6 / 3 DISTRIBUTION: 1. Property Owner 2. Jefferson County Assessor, ATTN: Data Control, 100 Jefferson County Parkway, Golden, 80419 3. Jefferson County Mapping, ATTN: Addressing, 100 Jefferson County Parkway, Golden, 80419 4. U.S. Post Office, 4210 Wadsworth Blvd., Wheat Ridge, 80033 5. Xcel Energy, ATTN: Correspondence, 11223 W. 3` Ave., Denver, CO 80223 6. Qwest Communications, Metro North Field -- Engineering, 5325 Zuni St., Room 728, Denver, CO 80221 7. Comcast, Attn: Scott Moore, 6850 S. Tucson Way, Englewood, CO 80112 8. Valley Water District 9. Clear Creek Valley Sanitation District 10. Arvada Fire District 11. Wheat Ridge Planning Division 12. Wheat Ridge Building Division 13. Wheat Ridge Police Department 14. GIS Specialist 15. Log File 16. Other: Wheat Ridge Sales Tax Dept. NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: DATE: ���� ��.ci.ir heat ridge.coms Site Vicinitv Nlap DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 13723 BUILDING INSPECTION LINE - 303-234-5933 Date CITY OF WHEAT RIDGE : 4/17/02 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) , Property Owner: GARY BRYAN Property Address: 9205 W 44TH AVE Phone: 421-2447 Contractor License No. : 18163 Company : Bighom Signs, Inc. Phone : 420 7264 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $4;156.00 I hereby certify that the setback distances proposed by this permit application are accurate, and Permit Fee : $111.25 do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations Plan RevieW Fee : $0.00 made are accurete; that I have read and agree to abide by all conditions printed on this Use TaX : $49.87 application, and that I assume full responsibil' for complia ce with the Wheat Ridge Bui ng Code (U.B.C.) and all other applicable W Ridge ordi ~ ces, for work under tNs per it. Total : $161.12 (OWNER)(CONTRACTOR) SIGNE DAT ~jca? Description : FREESTAN ING D U LE FA E MONUMENT SIGN 72 SQ FT PAINTED METAL CABINET ON MASONRY BASE, .L. ABEL ACRYLIC FACES W/ VINYL GRAPHICS, INTERNA FLUORESCENTILLUM. 2 J BUILDING DEPARTMENT USE ONLY lis mimm" SfC : Sq. Ft. : io4e a e Approval : MLC COMPLIES W/ SIGN CODE p`e• ~~o~`o ao°o aYaSr Zoning : C-1 ,e.yam~yb\~ertsa~~r~s~~ric`or MUST ALSO MEET N.E.C. REQS. Approval : BG c~~n6eqv~ce~~otSaaaoy FK w+-.~ . . . 1CA`pNe{S~'~aCQ~S~b\~Set'~,~ti,\t~ ~~p oa~l : ,°;e aeaQs °t'~4m~~ac aQ G0 ea.a 0S Occupancy : Walls : Roof : Stories'SVe b4+~~ ~idential Units : I Electrical License No : Company : Expiration Date : Approval: Plumbing License No : Company : Expiration Date : Approval: Mechanical License No : Company : Expiration Date : Approval: (1) This permit was issued in accordance with the provisions set fodh in yopur application and is subject to the laws of the State of Colorado and to the Zonin9 Regulations and Building Code of Wheat Ridge, Colorado or any qther applicable ordinances of the City. (2) This permit shall expire if (A) the work authorizetl is no[ commenced within sixty (so) days from issue date or (B) the building authorized is suspendetl or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normalry requiretl, provided no changes have been or will be made in Ihe original plans antl specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit (4) No work of any manner shall be done that will change the naturai Flow of water causing a drainage. problem. - (5) ContraCtor shall notify the Buildin9 Inspector lwenty-four (24) hours in advance for all inspections and shall receive wrilten appmval on inspection cartl before proceediing with successive phases of the job. (6) The issua a of a permii or the approval of drawings antl specifcations shall not be wnstmed to be a permit for, nor an approval of, any violation of the pro of he b~I ' des or any other ordinance, law, rule or regulatioa . ~ Chief Building In ector ISEPARTMENT OF PLANNING AND DEVELOPMENT oF wHE°T BiTII.DING INSPECTION LINE - 303-234-5933 x P ~ m CITY OF WHEAT RIDGE 7500 R'EST 29TFI AVENTJE WFEAT EtIDGE, CO 80215 - (303-235-2855) C~~ OftA~~ APPUR~~d3FON Property Owner: Property Address: Contractor License No.: GARy 6RVM 1816~w wAAV OWNER/CONTRACTOR SIGNATURE OF UNDERSTALIDING AND AGREEl4IENT I haeby certify that the setback distances proposed by tlils.peemit application aze accurate, and do ¢ot violate applicabie ordinances, niles or rogulations of the Ciry of Wheat Ridge or coveaaats, easements or iesQictions of record; thaz atl measuremcnts shown, a¢d allegatioas made are accucate;lLaT I have read and agree to abide by all conditions priated o¢ this applicatioa andthaT I assume fiill responsibilityfor compGaace with tfie Wheat Ridge Building Code (UB.G) aad all other appficable WheatRidgeOrdinances,focworkuade=thispeimit DATE Building Peimit Number: Date: Phone: 303 u'ZI) ZuU7 Phone: 303 LI20 l26q Construction Value: 4' l 5b ~0 Permit Fee: Plan Review Fee: Use Tax: Total: (OWNER)(CONIRACPOR). SIGNED Description: Freestanding Double face monument sign /~v-fl sq;; ft. painted metal cabinet on masonry base, IJ.L. label acrylic faces with vinyl graphics.,internal fluorescent illum. ZONING COMMENTS: M~ Approval: Zoning: BUILOING COMMENTSApproval: &(,; PUBLIC WORKS COMMENTS: Approval: BUII.DING DEPARTMENT USE ONLY n cc&-Q- 11/05~ ✓~~Sc /-IIPt~ ~l YP~ Occupancy: Walls: Roof: Stories: ` y Electrical License No: Plunbing License No: Mechanicat License No: Company: Company: Company: Expiration Date: Expiration Date: ' Expiration Date; Approval: Approval: Approval: (I) This pexmit was issued m accordence with Ute pcovisions set forth in your application and is subject to the laws of the State of Colondo and to the Zoniag Regulaliaas and Buildiag Codes of Wheat Ridgy Colorado or any other apptica6le o[d'wances of t}ie City. (2) '1Lis pexmit shall axp¢e if (A) the work authoriud is not commmced within sixty (60) days from iss¢e date or (B) the build'mg authorized is suspe¢ded or 'abandonedforaperiodof120daya (3) If Utis permit expues, a new permitmay be acquired for a fee of oao-half tlu amoun[ ¢oxmally requiced, proVidedno cha¢ges have 6een orwill be made ia tlte originalplans andspecifiratious anda¢y suspensionoraba¢doementhas notezecedcdona (1) yeac. 7f changes havebeen oxifsuspeasionorabandonmmt ezceedt one (1) yeer, fiili feu shal! be paidfor anew pecmit _ (4) No wark of any mamex shallbe done that will chmga the natutal flow of water causing adrainage problem. (5) ContacMrshsllnotifytheBu$dingInspectoxhveaty-foi¢(24)hou[sinadvanceforallinspectiobsa¢dshallreceivewrittenapprovsloninspee¢oncardbefore pxaceed'wg wifh successive phazu of thejab. ' .(6) The issuance of a peimit orthe appraval of dmwings and apecificaCOns shaLL not 6c eoatt[ued W be a permit for, aor an appcovat of any violation of the pcovicions of the 6vildmg eodes or any other sdinance, law, nile or ragulafloa ~ 05 Chief Building Ii ector ~T RD O 4b~ ~ 0 a ~ n ~ g e ~ ~ @ ~j ~ 0 ~ ~ ~ ~ 0 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~D @v~ ~n ~ ~ ~ R W nonono ~ ~ ~ ~ ~ ~ ~ a 0 tt aoo uu ~ ~ W. 44th Ave. = 0 LO y line 4D`I(o 0~ 9205 _CuENT: detail: Wheat Ridge auto center °aTE: 9205 W. 44th Ave. f-iLE: pEsiGi,IER 9r Gary Rains APPROb'AL: scALE: 1/100 I 15'-0 " W. 44th Ave. re~~n? ProPosed . -k sign 3 ~ '2-u 9205 ~0 ~ ~ SC~ F-t \r N; v Ir.r aA•• n..., v V. ~r~t i: SPIa v. - N,apertylir-._....._..._:............... nroGesed sign 9205 ' _ 12 1GCVd 52nai~ve. #1i4 - - gr ~'arY Rai1lS ~ nn ~J V4iicla'i I<IUCJ.c, k.V fSUUOO 1/2UL (303) 420-7264 ADDRE55 "I Q O S W. +I`l) DATE SUBMITI'ED PERMIT NUM3eR~ IYPc OF PcRMlT_ Y11 P.4rG1G~G CONTRACfOR ~~SA ~ ~~C~Ck • PHONE 10 , Q, ~ - J OWNER 1~ U L• 1~11~ ~ PHONE TYPE OF REQUEST NP IA ~ (,b Y'Z'1 rf~~C lCj Oar 1 pX L C,P A(EfERM17i1PP,ROVED3-Ib - CiR DATE AND REASON FOR PERMIT DENIAL REQUIRED CONDITIONS MET PRIOR TO PERMIT APPLILATION ? YES NO N/A CONDITIONS OF APPROVAL DA7E IN DA7E OUT BUILDING DEPARTMENT ENGINEERINGDEPARTMENT ~I - -C~E) a-4 c{' ~ PLANNING DEPAR7MENT ~{g /i -C1C{ ~ O FIREDEPARTMENT r~' ❑ GITYARBORIST 2)I14 Rc4c`P. .0c~n I~kc~'. C~6~~~C~-iC511S ❑ POUCE DEPARTMENT J v- ❑ SEWER DISTRIGT ❑ WATER DISTRIGf O OTHEK s .....~aQG~A'~GY~% / CERTIFICA"fE OF COMPLE710N BUILDING DEPAR7MENT DATE IN DATE OUT ~ ENGINEERING DEPARTMENr ❑ PLANNING DEPARTMENT O FIRE DEPARTMENT DATE LERTIPICATE OFOCCUPANLY / CERTIFICATE OF COMPLETION ISSUED TEMPORARY CERTIFICATE OFOCCUPANCY DATE W DATE OUT 0 BUILDING DEPARTMENT • ❑ ENGINEERING DEPARTMEN7 ❑ .PLANNIN6 DEPARtMENt ❑ FIRE DEPARTMENT PLANNING ESCROW CONDITIONS ENGINEERIN6 ESCROW CONDIilONS - AMOUNT PERMITIKAGKING FORM DATE TEMPORARY CERtIFICATE OF OCCUPANCY I55UED DATE EXPIRED --=7EPARTMENT OF PLANNING AND DEVELOPMENT BUILDIWG INSPECTION DIVlSION - 235-2855 CiTI` OF WHEAT RlDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 ~ Property Owner: B rc~, ftnJ ~ti~~ Property Address Q,s w y yv-4 Phone : li/~ya / a~ y ~ Contractor License No.: iG 13-a CompanY:.~Ao- 4,IS.lLD1N)G-- `Z~GaN C~ll~`xN) Phone:~G~a3_~/~% OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT ~ I hereby certify that the setback distances proposed by this permit appliwtion are accvrate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridr,e or covenants, easements or restriclions of record: that ail measurements shown, and.,allegations made are accurate; that I have read and agree to abide by all conditions printed on this - application, and that I assume full responsibility for c ffOnances, ce with the Wheat Ridge uing Code (U.B.C.) and all other applicable eat Ridge for work under this rmi. 1,3 < (OWNER)(CONTRACTOR) SIGNE _D.47E ~ Description Building Permit Number : Daie : ~ ; Construction Value : Permit Fee : to 0° ~ Use Tax: Total: $0.00 ~ Use: , BUILDING DEPARTMENT USE ONLY lQ ' CDCIl4s_~cLnac~ mUS~l~I'i~ SIC: E'~` F4_ P,pproval ! wt Q~N LQ~~p't~mmst ~omp~~ 5Ecti a+O- obt`& W.Chn e~lcde~:,5 Zoning : fi.I Approval: ~ v t Approval . anc/& Wr n V Roof : tories : ~ Eiectrical License No : Company: Expiratiori Date : Approval: Plumbing License No : Company: Expiration Date : Approval: r~ Ai~~~ 0 j D Mechanicai License No : Company : Expiration Date : Approvai: (o (1) This permit was issued in a¢ordance with the pioWsions set lorth in yopur applifatlon and is subject to the laws of the State o( CoIO2CO anO lo the Zoning - Regula6ons aM Buildiny Code ol Wheat Rid9e, Coloratlo or any oNer applicaole ordinances of the Ciry. - - (2) This pem~il shall ezpire A(A) the vrork authorizetl is nol commenced within sixry (60) days 6om issue tlate or (8) the buifCinp authorizetl is susperAeC or abantlaned fw a periad o1720 days. (3) U Nis pertnd expires, a new pertnrt maY be acquired br a fce ot one-Iwll the amounl normally requireC, provided no Ghanges have been M will 6e maEe in the ori9inal qlans anC speafiraUOns and any suspension w abandonmerd has not exceetleC ane (i) yeac , If rhanges are made or iY suspension or abantlonment exceeds uie (7) year, till fees shall be paid tor a new permit . (4) R'o work ot any manner shall be tlone Nat will change the naWrol flav of water causinq a drainage problem. (5) Convnctn[ shall r.oGy the Building Inspector hvenry-tour (24) hours in aAvance for aA inspections antl shall receive writlen approval on inspection prtl before proceediingwiUh successive phaxsotthe1'ob. - (e) 7Tn issuance ol agemiit a the approval of Crawings and specifcations shall nol be wnsWeO to be a pemul fa. rror an apprmal ol, any violation ot Ne provislons . ol the builtlinp f~Respr any,pther Ordinance. Ww. Nle or requWGon. hief Bui ding I ector For Mayor THIS PERM VAi.ID ONLY WHEN SIC;NED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 NOURS PRIOR TO INSPECTION f ERMIT TRACKING NOTES , Ivlarch 2, 1999 City of Wheatltigde Building Department 7500 W. 29th Ave. WheatRidge, CO 80215 Re: WheatRidge Auto Service 9205 W. 44th Ave. Building Use To Whom It May Concem: The proposed building will be used for an auto repair shop and a nail salon. The auto renair shop wili be limited to exchange of parts and maintenance. As the owner of WheatRidge Auto Service, I Cary Bryan, certify that there will be no open flame or welding activities within the building. Thank you,~ kB an March 2, 1999 City of Wheat72igde Building Department 7500 W. 29th Ave. WheatRidge, CO 80215 Re: WheatRidge Auto Service 9205 W. 44th Ave. Building Use To Whom It May Concern: The proposed building will be used *or an auto repair shop and a nail salon. The auto repair shop wili be limited to exchange of parts and maintenance. As the owner of WheatRidge Auto Service, I Gary Bryan, certify that there will oe no open flame or welding activities within the building. Thank yo ~ G~~an Code Correction List March 3, 1999 Owner: Bryan Builder: JAC Building Address: 9205 West 44"' Avenue ~ ~ Description: New commercial auto repair- second review 1.,, . Provide 16-0" "van-accessibie" parking stall. (96" stall with 96" access aisle) ~j 6'2. Provide specifications on sand and oil interceptor. t`v 3. Label all windows in west wall as 45 minute rated assemblies. 4. Update square footage at building data to account for upper level. 5. How are mechanical penetrations in west wall to be protected, due to distance to property line? tYiov~ FG7vW,,TR.A"i ror,,j,i""z) i~~oh" 6. Detail that building steel is to be bonded to service. 7. Specify all shop outlets are to be GFCI protected and mounted a minimum of 18" A.F.F. to lowest part of outlet. 8. All bathroom outlets to be GFCI protected. 9. Backflow device is to be installed before anytaps and show location and clearances around device on floor plan. 10. Provide cross-section of stairway and specify material. Please make these additions or corrections to the submittal and resubmit for review, if you have any questions or comments please feel free to contact me at 235-2853. Sincerely, Darin Morgan Codes Administrator Code Correction List July 15, 1998 Owner: Gary Bryan U Builder: Address: 9205 West 44th Avenue Description: New Commercial H14 - B Occupancy Cr~ Provide van-accessable handicap parking and signage. Change site plan scale to 1"=10' 69 Provide codes analysis ~OrW"- Per conversation with Gary Bryan - open flame is used during business operations on an occational basis which classifies this part of the structure as an H/4 occupancy, H/4. ~ occupancies that exceed 3000 square feet recjuire the entire buiiding be sprinklered. ~ Detail size and location of sand/oil interceptor. Storage mezzanine to be designed for 125 PSF floor load per UBC Table 16-A.1.e ~ Repair shop office will be requires one hour occupancy seperation between.w/4Toccupancy and B occupancy. . Provide listing stating glass block in west wall will meet bearing wall requirements due to distance from property line. ~ In handicap restrooms not more than one-half of the door width shall swing into 5'-0" clear floor space. ~ Provide 5'x5' level landing at te top of each exterior ramp to accomodate handicap manuvering space requirements. ~ Detail foundation support locations for 6x6 columns at front of building. ~ Detail location and size of reduced pressure backflow preventorto be installed where water line enters building. ~ Outlets in bathroom are to be GFCI protected and all outlet in bay area are to be GFCI protected and mounted 18" or more above finish floor. Outlets that are provided for a dedicated peice of equipment and on a dedicated circuit may be non-protected. . Detail how UBC Section 1204.2.4, ventilation requirements are going to be met. > Please make these additions or corrections to the submittal and resubmit for review, if you have any questions or comments please feel free to contact me at 235-2853. Sincerely, Darin Morgan Codes Administrator 1UI,- 9-96 FRI ':29 ~.Pvf Arvada Fire Protection District : FIRE MARSHALS' OFFICE P. 0. eox 9-D • . ARVADA, COLORA00 80001 Tetephone (303) 425-0850----FAX (303) 422-4589 FAX TRANSMISSIOAt DATE: )-2- A 8 To: A (-A z.~a T1- COI'1PANY S U? 1_f 3; 19 T IQ r n ca 3 ip .9 v e. r w c Da o~ - ADDRESS s '7 -s^o a t oz 4 IQ - CYTYi V.JI-ISl1T P~ (OOG Gcl TELEPHONE t aZ3 "7 - t.. S--/ FAXs cQz 5 -a&5-`7 FROM s S-r v cJ-r a. J- co L 6 n-Z < COMMENTSs NUMBER OF PAGES IPICLUDTNG COVER SHEBT: TF YQU DO NOT RL+CEIVE ALL PAGES PLZASE CALL 425-0850 JUI- y-yo FkI 7:29 4R1u1 Arvada Fire Protection District P.O. Bnx 3-D ARVADA, COLORADO 80001 TelCphone (303) 424-3012 - FAX (303) 432•7995 July 8, 1998 Mr Alan White, Acting ChiefBuilding Officiai City of Wheat Ridge 7500 W. 29" Ave. Wheat ltidge, CO 80034 itE: Wheat Itidge Auto ServiCe ,.99E3"W. 440 Ave. YZOS Dear Alan, P. ? = We have revjwed che plans for this building for conformance with the 1991 Uniftom Fire Code and have the follocving oomments. 1. Site: i. The address will need to be posted o» a temporary basis and permanently affixed to the building in a mittimum of 4 inch numbers on a contcasting background Uk'C 91 10.301(a). Amended 2. All-weather flre dept. access roadway, minnuum of 20 feet of vnobstructed width, capable of supporting the imposed loads of 52,000 lb. Fire appazatus need to be provided to within 150 £eet o£ all portions of the building prior to above grada constniction. UFC 91 10.204(a),(b). 3. The proposed access roadway ss 4 dead-end in excess o£ 150 feet and wili need to be provided approved provisions for Che turning around of fire appazatus.. LTFC 91 20.204(d). 4. Fize lanes will need to be posted, "No Parking PiKe Lane" with signs that meet City o£ Wheat Ridge Standatds. UFC 10:206. 2. Exits: L. The main exit doors if provided with key locking ¢evices shall be provic}ed cvith a sign stating," Tlus Door Is To Remain Uniocked Auzing Business Hours. UFC 91 12.106(c). aoc- g-yg FR1 7i :3r a.ti Page Two 2. The remain exit doors will need to be openable from the inside without the use of key of special knowledge. UFC 91 12.106(c). 3. Emergency Lighting: 1. Provide emergency tighting by ni$Itt Light or battery pack units. UFC 91 12.110(a) 4. Second Floor Use: 1. Please provide information on the use o£the second floor. 5. Service Bays: 1. Please provide iqformation on the type of repairs that vyill be performed vkithin the service bays. Specifically if cutting and wplding or work will be Iimifed to exchaqge of parts. UFC 91 Article 9. 2. Electrical receptacles will need to be instailed a minimum of 18 incfies above finished floor. UFC 91 29.105(b). 3. It appears that the furnace and water neater connected ivith the service bays ara within the sama area as the service bays and will need to be instalied at a minimum height of 18 inches above the fizushed floor. UFC 9129.105(a). 4. Waste oil wiGl need to be stored in approved containers or tanks. UFC 9129. 104(c). 5. Dirty rags wjil need to be stored within approved metal. containets with lids. UFC 91 11302(b). 6. Need infoimittion on the types of pils, soiveats, or flammable liquids that may be used or stored within the service bays. UFC 91 Article, 79 and 80. b. Kitchen: 1. Sheet ?t-3 indicates a door that is labeled Kitchen. Need information as to what type of equipfrieilt is to be itls~~lled within the kitchen. UFC 01 10.512, 10.5~3. F. 3 Jlil- 9-98 FkI 7:30 APri F. 4 Page Three 7. Fire Extiqguisher's: 1. Fire erctinguisher's shall be a minimuro of a 4-A zated, 10-1b ABC dry chemical units, futly charged with cuttent inspectiop tags, mounted not lgss than tEu-ee feet nor more than five feet from the floor to the top of the mounting brackgt at each exit door and at the top of the stairway to the second floor. UFC9110.501(a): Amended. 8. Carpeting: 1. Carpetiqg shall be a minimum of a Class II Critical Radiant Flux and documentation shall be provided prior to installation. UFC 91 Appendix IV-A. 9. Addirional Infarnaation: 1. Any code requirements arising frOm constriction will be addressed. 2. Twnety four hours notice required foz all inspections. 10. Requestp: 1. We would rgquest that a foundatipn only permit be issued until all weather access is provided to within 150 feet of all portioas pf the building. Sincerely, Azvada Fire Protection District ~v ~e Depusy Fire Marshal The City of 7500 bVEST 29TH AVEi'VUE • WHEAT RIDGE, COLORADO 80215 GWheat 16dge APPLICATION FOR MINOR DUPAPING/LANDFlLL PERiY11T NAII4c OF APPL1CAiVT: ADDRESS OF FILL: '~33 APPLICANT'S ADDRESS: )Z, 3eeq ~ LF ~ lz f 4 ~ 6t/`c~<~~7~~~ G o DATE OF APPLICATION: 2 AII permits shall be applied for through the Public Works Department. An approved permit is effeciive for a period of one (1) year from the date of issue and may be renewed. All fees shall be in 2ccordance with thosz fees established by the Uniform Building Code or other applicable City adopted Resolutions or Ordinances. Nofe: All pubiic improvements, when constructed, shall be maintained (by the respective individual(s) and/or company responsibie for the consiruction of that public andlor private improvement in the respective development) on a daily basis, or as needed, such that they are free of mud and other consYruction debris tracking from the site. Failure to comply with this requirement will resuit in the enforcement of Article 11, Specified Nuisances, Section 15-21 (3) of the City of Wheat Ridge Code of Laws. MINOR EXCAVATION AND FILL PERMITS 1. 1-50 cubic yards: No permit is required for dumping or excavation of earth materials, which do rot exceed fifty (50) cubic yards, provided, however, that any fill deposited is on natural terrain of less !han three (3) horizontal to one (1) vertical slope, or such fill is less than three (3) fee± in depth and is not intended to support permanent structures, and in addition, such fill or excavation does not obstruct or othernrise adversely affect any drainage way. Shouid any of the above standards be exceeded, or a drainage way be affected, a permit shall be required under the guidelines for No. 2. 2. 51-500 cubic yards: Dumping or excavation of earth materials not exceeding 500 cubic yards may be allowed with a permit approved by the City Engineer. AII applications are to be submitted on the appropriate completed application form and shail be accompanied by the appropriate fee and sketch plan indicating the following information before the permit will be issued. A. Location and dimensions of all property boundaries and structures on the site. B. Location and extent of areas to be filled and/or excavated. C. Location of existing and proposed drainage ways, irrigation ditches, etc., and indication of how and where historic runoff will be maintained on and throughout the site. D. Cross section area to be filled and/or excavated indicating original slope, new slope and depth of filL Pa,-e 1 of 3 (303) 234-5900 • ADMINISTRATION FAX: 234-5924 • POLICE DEPAFTMENT FAX: 235-2949 E. Statement which indicates the proposed use or purpose for said fill or excavation. F. Relative elevation of adjacent properties. G. Erosion control plan showing placement of control devices such as hay bales, etc. 3. 507-20,000 cubic yards: Operations in which earth material fill or excavation exceeds 500 cubic yards but does not exceed 20,000 cubic yards may be aliowed by a permit issued by the City Engineer after review of an application and supporting information. The following information shall be submitted with the required application form: A. A site pian, prepared and signed by a Colorado registzred , a scale of no less than one inch to twenty feet (1 profassional engineer at 20) which illustrates the foilowing: 1. Location and dimensions of ail property boundaries and structures on the site. 2. Location and extent of areas to be filled and/or excavated. 3. Location of existing water,vays and drainage courses indicating any changes: (For a site containing an established irrigation ditch, a letter of approval from the appropriate ditch company shall be required). 4. Location of existing and proposed points of ingress. 5. Location and extent of existing vegetation, proposed changes in such vegetation and methods of rehabilitation on site vegetation after earthwork operations are complete. 6. Erosion control plan. 7. Grading plan with existing (dashed lines) and proposed (solid lines) ground contours with contour intervals of two feet and spot elevations. 8. At least two cross sections (east to west and north to south) through the sho~,ving depth of fill and/or excavation. site 9. A drainage report my be required if site runoff characteristics are changed. 10. Relative elevations of adjacent properties and structures. 11. Statement or purpose of intended fill or excavation. 4. Pertormance Standards: The following provisions shail apply to all Minor Excavation and Fill Permits: A. Rehabilrtation: Within thirty (30) days after cessation of filling and/or excavation, rehabilitation forthe site shall have been completed in accordance with the approved plans. Rehabilitation shali consist of leveling, grading, landscaping, or any combination thereof to minimize potential erosion and be acceptable to the City Engineer. B. Debris: Debris andlor contaminants shail not be used except with the approval of the City Engineer. Page 2 of 1 "For the purpose of this Section, the term debris shall have the same meaning as the terms "garbage, trash, orjunk" as defined in the City of Wheat Ridge Code of Laws, Section 20-21." In no case shall debris or contaminates identified or classified as hazardous waste by local, state, or federal agencies be us2d as fili in any fill areas within the City of Wheat Ridge. C. Excavation and/or fill areas shail be graded to facilitate weed control until final grades are set and site rehabilitation and use occur (must be leveled with side slopes not to exceed 3 to 1). 5. Permit Fess' 50 cubic yards or Iess 51 to 100 cubic yards ~10.00 101 to 1000 cubic yards (CY) $15.00 for the first 100 CY plus each additional 100 CY or fraction thereof $15.00 1001 to 10,000 cubic yards (CY) $5.00 for the first 1000 CY plus for each additional 1000 CY or fraction thereof $60.00 10,000 cubic yards and over $ 4.45 $100.00 'City of Wheat Ridge Code of Laws Section 5-76. All permits shall be applied for prior to the start of fiil deposition or excavation operations. An ~r applied for after cutting or filling operations on site are in progress shall be subject to a double f e and other penalties as prescribed by the City of Wheat Ridge Code of Laws, Appendix A, Section 24.B. 6. Any fill requested under this permit within the 100 year flood zone MUST COMPLY 1NITH THE CITY OF WHEAT RIDGE CODE OF LAWS, SECTION 26-201, FLOOD PLAIN ZONING ORDINANCE: I HEREBYACKNOWLEDGE THAT THIS APPLICATION IS CORftECT AND i UNDERSTAND THAT I CANNOT START THIS PROJECT UNTIL THIS APPLICATION IS APPROVED. I SHALL COMPLY WITH THE LAWS OF THE STATE OF COLOR.qDO AND WITH THE ZONING REGULATIONS AND BUILDING CODE OF THE CITY OF WHEAT RIDGE. ANY VIOLATION OF THE ABOVE TERMS WILL CAUSE IMMEDIATE REVOCATION OF THIS PERMIT AND COMMENCEMENT OF ENFORCEMENT PROCEEDINGS BY THE CITY OF WHEAT RIDGE. THIS APPROVED PERMIT WILL BE KEPT IN MY POSSESSION OR PERMANENTLY ON THE JOB SITE. CITY QF WHEAT RIDGE: City ngineer 2A0 ker Appr vo al Date ---•-1 Page ; of 3 APPLICATION FOR RIGHT-OF-WAY CONSTRUCTION PERMIT Date (PLEASE PRINT CLEARLY AND PILL OUT FORM COMPLETEI.Y) Applicant Address City State Location of Construction (address) _ Purpose of Construction Contractor Superintendent Estimated Start Date: Estimated Completion Date: BASIC PERMIT FEE FOR EACH OPERATION $ 75.00 CONCRETE FEES Sidewalk LF @ $.1 O/LF ($10 min.) Curb & Gutter LF @$.10lLF ($10 min.) Curbwalk LF @$.15/LF ($15 min.) Driveway LF @$.15/LF ($15 min.) Crosspan Fillets Curb Ramps EA @$15.00 TOTAL CONCRETE FEES $ STORM SEWER FEES Storm Sewer Inlet EA. @ $15.00 Storm Sewer Manhole EA @$15.00 Misc.Structures EA @ $15.00 TOTAL STORM SEWER FEES $ NEW STREET CONSTRUCTION PEES Eaithwork SY @$.O5/SY ($10 min.) Subgrade Prep. SY @$.OS/SY ($10 min.) Pavement SY @ $.10/SY ($20 min.) TOTAL CONSTRUCTION FEES ; STANDARD STREET CUT EXCAVATION FEES Size of Cut Water_ Sewer _ Gas _ Electric_ Phone _ Cable _ Utilities: Main _ Service All excavated areas (includes pavement restoration) SF @$.30/SF ($15 min) TOTAL EXCAVATION FEES $ GRAND TOTAL OF FEES DUE : ALL PERMITS must include a sketch of the proposed traffic control plan for the designated area of construction. For your convenience, a blank sheet of graphed paper is available with this application for this purpose. Please be aware that permits will not be processed until the traffic control plan has been received and approved. CONSTRUCTION SHALL NOT BEGIN UNTIL PERMIT FEES HAVE BEEN PAID AND THE PERMIT HAS BEEN PROCESSED. THE PERMIT AND TR.4FFIC CONTROL PLAN SHALL BE AVAILABLE ON THE JOB SITE AT ALL TIMES. ABSENCE OF A PERMIT ON THE JOB SITE MAY BE GROUNDS FOR CESSATION OF ALL CONSTRUCTION ACTIVITY. Signature of Applicant Zip Phone Title 08/10/1998 10:10 3034210128 ' ~ ~ ~ ~ ~ ~ ~ 4 ' SECUITY PLUMBING PaGE ei ~ . • ~ ~ . F 7'4" 6 a.. ~ --72„ ~ ~ ~4` - ; ~ ~ `a, I 4 i _ Z": T A B ~ Q _ ~ b 1-01 1 C¢tdons 1 Q A B W eti ht- Boz W ei ht-Gover bf oded 1060 40" 8~' 46" 60° 13,348 I6s 11040 1145 44" 4,Z" 48 621 14.068 !6~,z 6,552 tbs 11050 125Q iss/;• a31, 50 64 14,248 t6s 6,552 t6s 11060 ' 156Q 54' 52" 60" 79 16,278 bs 6,552 t6 n070 Nates: - Reinforcement• Bar- 8 z 6 10/10 Wire bfesh &.3- #4 Horizont¢t fTr. Walts CoveT- jy5 O 8" O.C.E.K. #5 Around Xol¢s H-2Q Loading. BaffeL Fleight dc Lxat i ti Pi Q Sh ld Hotes Fer Local Code For Each fnslaUatim l G d A T o a on pe ceording o Loca e. trzstal f ou 9¢ S¢coridary Compartmant Has A Vdtuma E¢uaC To 113 Qf TotaC Capacity. Copeland Enterrorises Inc. THE.~. 904 South Ltipan ~QrS~~~~afaa~ Denver, CO 60223 kfcS~~`=('4` 4- 08/1011998 10:10 3034210128 SECUITY PLUMBING PAGE 01 ~ ~ ~ . 4'• ~ 1 7 . 4,.' 72„ 7-- r I 24~ 24' ~ ~ ~ ~ ~ 2 ? A B . ~ i i C¢ldons I Q A 8 Weti ht-Boz Weti ht-Gover Model 1060 40 8'° .46 60n 13,348 t6s 11040 1145 44 " 42" 48 62 14.068 l6 ~ fi 55Z lbs 11050 1450 ISglr 3314 50n 64 19 ,GQU lb.`', 6t55216S I10UQ 150a 54 ' 52° 60 " 74 16,278 6s 6,552 lG 11070 Nater: - R¢tinforcem.en.t- Bor- 8 s 610/10 Wire bfesh &.3- #4 Horizent¢t fn Walls Cov¢r- ~t5 O 8° O.C.E.K. #5 Around Hol¢s. fl-2Q Loadittg. BaffeL Hei9ht dc Locatio Holes Per• Locat Code For Each fnst¢itafion. tion Q ld B¢ Accordin To Loc¢L Code tali f Pi Shx l . a , pe ns m Secondary Comparfm¢nt Aas A Vdtume ~quai Tu 113 0f Totat Capcctity. Copeta~~ Enterprises Inc. 904 aouiit Ltipdn wm1k1afaa# Dertver, CO $0223 k ~ ~ ~ 08/10/1998 10:10 3034210128 ~ ~ SECUITY PLUMBING PAGE 01 . • ! ~ - 6 T'-4" 72.. . ~ " ' 24 _ ~ ~ 2 - . - . : . ~ ! , z ~7 A B ~ Q ~ i ~ Cattons I 4 A 8 Wei ht-Boz Weti ht-Cover Modet 1060 40" 8" 46" 60" 13,348 t6s 11040 1195 44° 42" 48" 62 14,06816lz 6552 Cbs 11050 1250 ~1/10 33/4 50" 64 14.248 Ib~ 6,552lbs 11060 150 54' 52° 60" 74 16.278 6s 6,552 C6 t1070 Nater: - Retinforcement- Bax- 8 z 6 10/10 Wire bfesh &.3- #4 Horizottt¢C !n WaLis Cov¢T- #5 O 8° Q.C.E.W.: #5 Arourtd Xolm H-20 Loadircg. Baffet Heighi & Lx¢tion Pt Hotes Per Locat Code For Each fnsiaUation. Instattation Uf Pipe S7toutd 6¢ Aceording To Local Gade. S¢condary. Comp¢rtment Eas A Votume EquaC To 113 OF TotaL Capacity. :Copeland Entexprises Inc. fpt.~= 904 S4~th Lipan Dertver, CEt 60223 b= k-- BUILDING DEPARTMENT (303) 235-2855 CITY OF WHEAT RIDGE * * /J ' Notice Job Located at qZ 6 5- IY- ' L~`4 1:1- G (79 I have this day inspected this structure and these premises and have found the foliowing violations of City and/or State laws gov- erning same: a', !J es4 ABi AP'-_ You are hereby notified to correct the foregoing violations. When corrections have been made, call for inspection. Date Inspector for Building Dept. DO NOT REMOVE THIS TAG FORM WR6-22 - BUILDING DEPARTMENT (303) 235-2855 CITY OF WHEAT RIDGE * * Correction Notice ~ Job Located at I have this day inspected this structure and these premises and have found the foliowing violations of City and/or State laws gov- erning same: ` /'i6e G'l/G!/L (/iai~dd Sti-~~~1Jp~ You are hereby notified to correct the foregoing violations. When corrections have been made, call for inspection. Date a/,7 7// ri~" Inspectorforf3uliding . DO NOT REMOVE THIS TAG FORM WR6-22 - The Ciry of 7500 WEST 29TH AVENUE • WHEAT RIDGE, COLORADO 80215 GWheat 1; Ridge September 8, 1999 Wheat Ridge Auto Service c/o Gary Bryan 9205 W. 44' Avenue Wheat Ridge, GO 80033 RE: 9205 W. 44`h Ave. - Certificate of Occuoancy Dear Mr. Bryan, The following letter is to inform you that you are currently in violation of Section 109 of the Uniform Building Code, which states, "No bui[ding or structure shall be used or occupied, and no change in the existing occupancy classification of a building or structure or portion thereofsha[1 be made until tl:e Building Officia[ has issued a certifzcate of occupancy therefor as provided herein. " Your contractor was notified by me during the final electrical inspection that it would be all right for you to move your equipment into the new building and set up, but that occupancy would not be permitted until all outstanding issues were resolved and approved. Due to apparent mis-communication between your contractor and yourself you are illegally occupying the above referenced address. The only remaining outstanding issue is the storm sewer connection to 44' Avenue. This should complete the drainage requirements so your engineer can certify the site for drainage improvements and the Wheat Ridge Public Works Department can review and approve the engineer's letter. Please be aware that if these outstanding issues are not resolved and approved by 3:00 n.m., Fridav, Sentember 10, 1999, the City will be forced to require that use of the building be discontinued and the structure be vacated until all outstanding issues are completed and approved. Failure to discontinue use and vacate the structure could result in utility services being disconnected for the structure. Should you have any questions or comments regarding this issue please feel free to contact me at 303-235-2853. Sincerely, D ari~ o6~~ Codes Administrator cc address file Bob Goebei, Acting City Manager, Public Works Director Alari White, Planning and Development Director Greg Knudson, Development Review Engineer JAC Builders, Inc, c/o John Cellesin (303) 234-5900 • ADMINISTRATION FAX: 234-5924 • POIICE DEPARTMENT FAX: 235-2949 N-~~ "c,=*.~at F:?,Ii ~ ~0>c -Vr:~"~~rnittell 7500 West 29th Avenue Planning: Parks & Recreation: Public Wo^ks: Fax: DATE Name, Orgnnization: 46v~~a3' Fax: /~S 0 Phone; From: CieS , Dept: Subject: # of Pages: Comments; Planning Parks & Recrention ❑ Public Works ❑ / Wheat Ridge, CO 80215 Phone # (303) 235-2846 Phone # (303) 235-2877 Phone # (303) 235-2861 Phone # (303) 235-2857 (Including cover paqe) Z- Original to follow in the mnil ❑ Yes "o G HP OfficeJet Personal Printer/Fax/Copier Fax Log Report for DEVREVFAX 303 235 2857 Sep-08-99 04:53 PM Identification Result Paees Tvne Date Time Duration Diaenos6c 93034241450 OK 02 Sent Sep-08 04:52P 00:01:02 002586030022 7.ao DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 8606 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 3/10/99 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Cs c~j-L-' L _ 1~,u LiC' r" Property Address: 9205 W 44TH AVE Phone: 421-2447 Contractor License No. : 19432 Company : JAC BUILDING, INC. Phone : 424-1800 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibiliry for compl'ance with the Wheat Ridge Building Code (U.B.C.) and all other applic eaf Ridge ordi a e, for work under this permit. (OWNER)(CONTRACTOR) SIGNED i DATE Description : New commercial car service and nail salon Construction Value : $280,000.00 Permit Fee : $2,001.75 Plan Review Fee : $1,301.14 Use Tax : $4,200.00 Total: $7,502.89 Use : BUILDING DEPARTMENT USE ONLY mmmmommm SIC : Sq. Ft. : 4556 Approval : MLC All signs & fencing must be by separate permit. Landscape must Zoning : C-1 comply w/Sec. 26-32 of the Wheat Rldge Code of Laws Okay Approval: DM Approval:GK See attached P.W. review sheet, ENGINEERING FEES $550.00 Occupancy : Walls : Roof : Stories : Residentiai Units : Electrical License No : 18269 Company : B B Electric Expiration Date : 2/28/2001 Approval : Plumbing License No :18968 Company : Clyde's Plumbing & Heating Expiration Date : 11/19/98 Approval: Mechanical License No : 19965 Company : HIGH PLAINS HEATING Expiration Date : 5/5/99 Approval : (i) This permit was issued in accortlance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any ofher applicable ordinances of the City. (2) 7his permi[ shall expire if (A) the work authonzed is not commenced wi[hin sialy (60) days from issue tlate or (e) the building authorized is suspended or abandonetl for a period of 120 days. (3) If tihs permit expires, a new permit may be acquired for a fee of one-half the amount nortnally required, provided no changes have been or will be made in the orignal plans and specifications and any suspension oi abandonment has not exceetletl one (1) year. If changes are made or if suspension or abandonment exCeeds one (1) year, full fees shall be paid for a new permit. (4) Noworkofanymannershallbedonethatwilichangethenaturelflowofwatercausingadrainageproblem. (5) Contractor shall notify the Building Inspec[or hventy-four (24) hours in advance for all inspections and shall receive wntten approval on inspection card before (6) The issuarice of a permit or the approval of drewings and specifications shall not be consW ed to be a permit for, nor an approval oF, any violation of the provisions of the if{ling cotlysor any other oMinance, law, rule or regula6on. . ~'l~t'~.~•~°-°'"' U z W ~ U U O ~ O F ~ U Fr~iW F~ E ~ rWl V ~ c- ~ m ~ 0 W m o mg ¢ C O F > N a<s W t o = W U 3C~m o V ~ o m L U 3 m LL ~ O 3 a m N LO j O Ct= (L) a~o 3 m ¢ L D 6.F ~ O 'N m ~ 3 ~ E 00.5 `oa°`c 3 m w d ~ N c p mm ~ oa> aa y to mm yaa W ~ 000 m 0 O H Q O a r C 9 m R O ~ v m a m ~ ,omm ..a n (9 C m M C ttl y U y y O ~ a E c.. a , 10 - c ao a tE c m mNa ~ y d U ~ D 0 p ~aUa N A p T w m C A ~ E > , o N 9 m N m m c m y U =p M = mv ~ ..¢a¢ V N N N Sa %mLL ~ 2 w Z 0 M M O O co U c H rn ~ ~ m U Q 7 Q 0 U Q Q H Z U 0 ~ Ql ~ ~ K ~ b ~ s 3 N 7 C N 1 ¢ t a ~ 3 l() O N 01 f/1 Z N 0 ~ a O O 2 Q U ~ W ¢ ~ O (a7 a w ~ U i E e 0 v O ~ LO Z \ .ro r Q v ~ O ~ S W ~ a Q 7 a ~ z O J 0 LL W S F ¢ O LL m A ~ d O c 0 a ~ 3 y ~ a Ir J N a m m t> L > O T N U ~ d N ~ « E C p ~ T m ~ E `m y a a ~ U N Q t ~ O N c m tE U U - O m Z U ~ ~ ~ O N O n ~ N c _ ~ c c a E D ~ Q O T m O~ N ~ c f U N ti d E ¢ 3 9098-66 uaewnNiiwaaa Date: A Certiticate of Occupancy or Completion has been requested for: ADDRESS: /0w~5 CC> ~ ~ . ~ Purpose of Structure:.a D[., ()t,cQ11 ~ Building Department Approval: (Dl'- Remarks: Zoning Approval: (f ) \ L"- I - ( 9 Remarks: Public Works Remarks: Fire Mazshall Approval:a (IfApplicable)-l , ~ Remarks: Sanitation District Apl (If Applicable) Remarks: Water District Appro-v (If Appiicable) , s.[e cA-e ~ o-yi -A4 cv s-eo/ 9 -1¢-99 Remazks: sEY-i4-ss 'AU 10 :43 nM FA ; 110. 3u34327,995 P. Arvada Fire Department lw Organizational Excellence In Fire, Rascue, and D(sasfer Services. Fax Transmittal Date: 5 T ~ 9 ~ To: -DA Company: s U. -..19 Location: Fax Number: Number of Pages Including Cover Sheet: z3 From: -'r r~ z 75 T~ e, _ P.O. Box 3•D; 6503 Simms Street 0 ARVADA, COLORADO 80001-0060 a (303)424-3012 0 FAX (303)432-7995 SBP-14-g9 10:44 .aM F."v~; 1,10. 3034327995 P. 2 Arvacla Fire Protection District p.0. 9ox 3-0 ARYAOA, COLORADO 80001 Talephone (303) 424•3012 - FAX (303) 432-7995 OCCUPANCY COMMEN'P SM2 . . , , Name of Facility: i i Address: i. A CERTIFICATE OF OCCiIPANCY MAY BE I3SUED ` ~ Date 5i ature 2. A TFMPORA1tX CERTIFiCATE OF OCCUPANCY IvTAY BE ISSUED PENDTIdG COMPLETION OF'PHE FOLLOWING: Date 3. OCCUPANCY iS NOT RECOMIvtENDED iJHTIL T~ ~OVE ITEMS ARE COMPLE'I'F, Date Signamre SEP-14 -9y !`?ED 10: 44 AM FN~ Pdv. 303432?995 P. 3 Arvada Fire Proteetion District P.O. Box 3•D ARVAQA,COLORADO 80001 Telephone (303) 424•3012 - FAX (307) 432•7995 OCCUPAI3CY COMA'IENT SHEET : I ~ Name of Facitity: iq Pr-tzr--~-ea Address: 19a o 1. A CERTIFICATE OF OCCUPANCY MAl' BE ISSUEA ~ 9-ia-vr _ ~ $ignature Date 2. A TEMPORARY CERTIFICATE OF OCCUPANCY MAY BE ISSMD PENDING COMPLETION OF THE FOLLOWING: 3. OCCUPANCY IS NOT RECOMIMENDED LTNTIL T'M ABOVE xTEMS ARE COMPLETE Date 5ignature M cr) ~ J~illJ tn ~ LLJ Z 0 M~y ,~b,"~.: Q 0 o ~ V ..J C~ W Z. ? a ~ W- J - Q ~ o O W W = ~ ~ ry . W r W ~ S O O ~ ~ z A W N OC Q ~ S~ O v ~ Lu cl) a ~ ~ C. o ~~V Z V) Q t Y a P'~: z cl) U O W N V ) N LLJ z C) U a a ~ U U 0 W a ~ ~ ~ ~ ~ ~ ~ w 0 w ~ S2 ~ w 0¢ I.i M ~ 0 m 0 z ~ w z J ~ w. a O ¢ Z p_ ~ a w ¢ ¢ i p ~ a U Y ~ Z Q U pc ° z ~ m z m 8 ~ ~ 0 ~ . ~ 0 U W ( m - (D z ~ ~ ~ Z z 0 ir a W W U o ri) J J Q Z ~ U) F- cn ~ ~ ¢ O U W Z ° w - , W a 0 cn Z ~ ' 0 O ~ o c . p, ` (D o C co ~ L L Q ~ 0 W z 0 Cl) z W W m ~ a 2 W ~ m Q Z W W cc U z 0 U O Z ~ ~ 0 Q- 0 w Z ~ ~n z m Z) ' A O s Z ~ 0 0 0 ~ C m c ; N 6 E ~ m ~ ro w a _ m ~ H ~ ~ Q Q ~ --C~ :I ~ Y7 ~ ~ N 'pp ~ ~ ~Y ~ ` r ~ 73 0 C 0 m C m a) ~ m N C (D E ai C ) C c o C _ m Q '~y j m o ~ ~ oif N C. otS C N ~ N l6 ~ C 0 ° ~ ~ i N N ~ R C ~ N N ~ Q 0 ..d. Y LL ~ o o [ a [ w w a 2 ~i oC iL d ~ ~ ~ O N C ~ ~ 0 .`o 4 ~ m y ~ 7 ~ a° ` O a LL m ~ W x H J W z N ~.5:. ' ~ W ~ cc a ~ r ~ ~ III 00 W Z O a Z I a V III O I Arvada Fire Protection District P.O. Box 3-D ARVADA, COLORADO 80001 Telephone (303) 424-3012 - FAX (303) 432-7995 July 8, 1998 Mr. Alan White, Acting Chief Building Official City of Wheat Ridge 7500 W. 29`h Ave. Wheat Ridge, CO 80034 RE: Wheat Ridge Auto Service 9205 W. 44h Ave. t Deaz Alan, We have reviwed the plans for this building for conformance with the 1991 Unifrom Fire Code and have the following comments. l. Site: The address wili need to be posted on a temporary basis and permanently affixed to the building in a murimum of 4 inch numbers on a contrasting background UFC 91 10301(a). Amended 2. All-weather fire dept. access roadway, minimum of 20 feet of unobstructed width, capable of supporting the unposed loads of 52,000 lb. Fire apparatus need to be provided to within 150 feet of all portions of the building prior to above grade construction. IJFC 91 10.204(a),(b). 3. The proposed access roadway is a dead-end in excess of 150 feet and will need to be provided approved provisions for the turning azound of fire apparatus.. ITFC 91 10.204(d). Fire lanes will need to be posted, "No Parking Fire Lane" with signs that meet City of Wheat Ridge Standards. UFC 10.206. 2. Exits: L. The main eut doors if provided with key locking devices shall be provided with a sign stating," This Door Is To Remain Unlocked During Business Hours. t7FC 91 12.106(c). Page Two 2. The remain exit doors will need to be openable from the inside without the use of key of special knpwledge. UFC 91 12106(c). 3. Emergency Lighting: 1. Provide emergency lighting by night light or battery pack units. UFC 91 12.110(a) 4. Second Floor Use: 1. Please provide information on the use of the second floor. 5. Service Bays: 1. Please provide information on the type of repairs that will be performed within the service bays. Specifically ff cutting and wplding or work will be limited to exchange of parts. UFC 91 Article 9. 2. Electrical reGeptacles will need to be installed a minimum of 18 inches above finished floor. UFC 91 29105(b). 3. It appears that the furnace and water neater connected with the service bays are within the same azea as the service bays and will need to be installed at a minimum height of 18 inches above the finished floor. UFC 91 29.105(a). 4. Waste oil will need to be stored in approved containers or tanks. UFC 91 29.104(c). 5. Dirty rags will need to be stored witlun approved metal. containers with lids. UFC 91 11302(b). 6. Need infprm,ation on the types of pils, solvents, or flammable liquids that may be used or stored within the service bays. UFC 91 Article, 79 and 80. 6. Kitchen: 1. Sheet A-3 indicates a door that is labeled Kitchen. I^Ieed information as to what type of equipment is to be installed within the kitchen. UFC 91 10.512, 10.513. Page Three 7. Fire Extinguisher's: Fire extinguisher's shall be a minimum of a 4-A rated, 10-1b ABC dry chemical units, fully charged with cunent inspection tags, mounted not less than three feet nor more than five feet from the floor to the top of the mounting brackpt at each exit door and at the top of the stairway to the second floor. LTFC 91 10.501(a). Amended. 8. Carpeting: 1. Carpetiqg shall be a minimum of a Class II Critical Radiant Flux and documentation shall be provided prior to installation. iJFC 91 Appendix IV-A. 9. Addirional Information: 1. Any code requirements arising from constriction will be addressed. 2. Twnety four hours notice required for all inspections. 10. Requests: l. We would rqquest that a foundation only pernut be issued until all weathqr access is provided to within 150 feet of all portions of the building. Sincerely, Arvada Fire Protection District kev-e S~e gl er Deputy Fire Mazshal DEPARTMENT OF PLANNWG AND DEVELOPMENT Building Permit Number : 9179 BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE Date : 7115/99 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner: Property Address : 9205 W 44TH AVE Contractor License No. : 19734 Phone: Company : Victory Plumbing Co., Inc. Phone : 422 4063 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that i assume full responsibiliry for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) Description : Underground sprinkler system (20) heads Construction Value : $1,500.00 Permit Fee : $54.00 Plan Review Fee : $0.00 Use Tax : $22.50 Totai : $76.50 Use: Electrical License No : Company: Plumbing License No : Company : Mechanical License No : Company : Expiration Date : Expiration Date : Expiration Date : Approvai: Approvai: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is su6jec[ to the laws of the State oF Coloratlo antl to the Zoning Regulations and Builtling Code of Wheat Ridge, Coloratlo orany other applicable ordinances of the Ciry. (2) This permit shall expire if (A) ihe work auihorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If ihis permit ezpires, a new permit may be acquiretl for a fee of one-half ihe amount normally required, provided no changes have 6een or will be made in the onginal plansand specifcations antl any suspension or abandonmen[ has not exceeded one (7) yeac If chan9es are made or if suspension or abandonment exceeds one (1) year, full fees shall be paitl fora new pertnit . (4) No work of any manner shall 6e done thatwill chan9e the natural fiow of water causing a tlreinage problem. (5) Contractor shall notify the Builtling Inspectortwenry-four (24) hours in advance for all inspections antl shall receive wriHen approval on inspection card before proceediing wi[h successive phases of fhejob. (6) The iss ce of a p rmit or the approval of drawings and speciFiralions shall not be cons[rued to be a pefmi[ for, nor an approval of, any violation of the provisions of the ~or any other ordinance, law, rule or regulation. 9 Chief Building Inspector DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, co $oz,s APPLICATIo N Property Owner: ~;Apo/ -)32yA N d~~ PropertyAddress: qZUJ~ W~ V y+~ t~`~ Phone: ,ll4 f3 LDG. Contractor License No. 79 Company : V/G"f U62 L/ pL/3(, , j7j1)G Phone : Lf Z 2- _/fD63 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurete, and do not violate applicable ordinances, rules or regulations of the Ciry of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.Q) and all other applicable Wheat Ridge ord nces, for work under this pe it. ~ Construction Value : / 5p a° Permit Fee : ~ Use Tax : ~.asa Total : (OWNER)(CONTRACTOR) SIGNED ~DATE~ LISe : Description BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval : Zoning : Approval: Approval: Occupancy: Electricai License No : Company : Walls : Roof Stories : Residential Units : Mechanical License PJo : Plumbing License No : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approvai: Approval: Approval: (7) This pertnit was issued in accoMance with the provisions set forth in yopur appiiraGUn and is subject to the laws of the State of ColoreCO and to the Zoning Regulations and Building Code o! Wheat Ridge, Coloratlo or any other appliwble ordinances of the City. (2) This pertnit shall expire "rf (A) the work authorized is not wmmencetl wiNin sixty (60) days trom issue tlate or (B) the building authonzed is suspended or abantloned for a penotl of 120 days. (3) IF this pertnit expires, a new permit may be acquiretl for a fee of onc halt the amount nortnaliy requiretl, provitletl no changes have been or will be made in the ori9inal plans antl specifications and any suspension or abantlonment has not exceetled one (i) year. If chan9es are made or if suspension or abandonment exceeds one (t) year, full fees shall be paid for a new pertnit. (4) No work of any manner shall be done thai will change the naN21 flow of water causing a d2inage problem. (5) ConVactor shall no6ry the Builtling Inspector iwenty-four (24) hours in advance for all inspections and shall receive wntten approval on inspectlon carU before proceetliing with successive phases of Nejob. (6) The issuance of a pertnit or the approval of tlrewings antl specificafions shall not be consWed to be a pemit for, nor an approval of, any violation of the provisions of the building cotles or any other ordinance, law, rule or regulatloa . ChiefBuilding Inspector oti DEPARTMENT OF PUBUC WORKS BUILDING PERMIT APPLICATION REVIEW cOt o a P9~ Date:'3 CaseBuilding Perntit No.: Location: °V205 U) • QQ-Ah -A0v'6 . Attention: Building Department I haue reviewed the attached materials submitted in application for approval of a-nc~+ c~+~'►e+c i 4 (c~', at the above referenced address. Please note the summary comments below. 1. ~ Boundary Closure: X OK _ Not OK; refer to stipulations. 2. Drainage: a. Drainage plan and report needed _ b. Drainage plan not needed c. Drainage provisions have been reviewed and aze found to be: ~ OK Not OK; refer to stipulations. 3. NPDES Permit Required: Yes ~ No 4. ~ Legal Description: ~ OK _ Not OK; refer to stipulations. If not OK, please explain: 5. ~ Public Improvements: a. street paving needed: Yes ~ No b. curb and gutter needed: Yes ~ No c. sidewalk needed: Yes ~ No d. street lights needed: Yes ~ No e. storm sewer needed: Yes ~ No f. escrow required: _ Yes -)!L No If an escrow is required, for what improvements? Amount of escrow: 6. Development Agreement required: _ Yes ?C' No If Yes, for 7. Traffic impact analysis and report required: Yes No 8. State Highway Access Permit needed: Yes X No 9. ~ New roadway or alley R.O.W. dedication recommended: _ Yes L~ No If yes at is recommended? 10. All stin dedicated roadwaYs/alleys meet the standazds of the City: Yes _ No If , w' h do not and what is requested: 11. ~ R AL: The thbtic Wor s Department has reviewed this request and hereby gives its ap r al, subject e abov and/or attached stipulations. 31g l9~ Signature g Knudson Date 12. _ NO APPR VAL: The Public Works Department has reviewed this request and does not give its approval for the reasons stated: Sirature Crreg I{nudson Date 13. ~ Sttpulations attached: _ Yes ( r 14. % Summary Comment4: ~c~a.•n4~c. ~e~~ Jtv-wh G%v; ( unq. -aV- " ' 155o QL.fo~wlaprtnY2.s,n PUBLIC WORKS REVIEW FEE STRUCTURE FOR BUILDING PERMIT APPLICATIONS Date Applicant 3AG (1hn cC 1t iSe Y1 Phone #03~ -4Z4 - 1$Cb Location of Construction (address) I205 vi .4 g' i M Poie Purpose of Construction Y1 tw CanvlMCr Gq( Ga.r SCc-tfG Building Permit Value $Z.IO, ODO .00 Commercial ~ Residential _ DEVELOPMENT REVIEW FEES (this section to be completed by City) Deveiopment Review Processing Fee: $50.00 $ SO , o0 Single Family Residentiai Review Fee: $25.00 [includes review of construction drawings for improvements in public right-of-way] $ _ O- Multi-Family/Commercial: .$50 minimum fee [confirmation of existing technical documents]. $500.00 maximum fee [includes review of construction drawings for improvements in public right-of-way, review of preliminary/final drainage study do and erosion control plan(s) if required] $ S~~ Site Plan: $50.00 (Not applicable for single family residential) Right-0f Way/Easement $40.00 + $5.00/page recording fee Development Agreement Residential = $50.00 Commercial = $100.00 State Highway Access Pertnit: $75.00 application fee Traific Impact Review & Report: $100.00 processing fee Flood Plain Variance: Ciass I=$75.00 Class il =$150.00 TOTAL REVIEW FEES: (due at time of building permit issuance) $ _ O $ _ d $ - ~r $ ~ O- $ -O- $ ~O- $ Please note that additional fees will be assessed for those permits related to construction of public improvements. If you have any questions, please feel free to contact the Devebpment Revievr office at 235-2868. Signature of Applipnt Date~/ ~ March 2, 1999 City of Wheatliigde Building Department 7500 W. 29th Ave. WheatRidge, CO 80215 Re: WheatRidge Auto Service 9205 W. 44th Ave. Building Use To Whom It May Concern: The proposed buiiding will be used for an auto repair shop and a nail salon. The auto repair shop will be limited to exchange of parts and maintenance. As the owner of WheatRidge Auto Service, I Gary Bryan, certify that there will be no open flame or welding activities within the building. Thank yo ~ fi~~an Mazch 2, 1999 City of WheatTtigde Building Department 7500 W. 29th Ave. WheatRidge, CO 80215 Re: WheatRidge Auto Service 9205 W. 44th Ave. Building Use To Whom It May Concern: The proposed buiiding will be used ior an auto repair shop and a nail salon. The auto repair shop will be limited to exchange of parts and maintenance. As the owner of WheatRidge Auto Service, I Gazy Bryan, certify that there will be no open flame or welding activities within the building. T ank you G rYan aT4 Arvada Fire Protection District P.O. Box 3-D ARVADA, COLORADO 80001 Telephone (303) 424-3012 - FAX (303) 432-7995 Mazch 5, 1999 Mr. Darin Morgan, Codes Administrator City of Wheat Ridge Building Department 7500 W_ 29' Ave. Wheat Ridge, C0 80034 RE: Wheat Ridge Auto Service 92Q5 W. 44' Ave. . ` Dear Darin, We have reviwed the plans for this building for conformance with the 1997 Uniform Fire Code and have the following comments. l. Site: 1. The address will need to be posted on a temporary basis and permanently affixed to the building in a minimum of 4 inch numbers on a contrasting background L7FC 97 901.4.4. Amended 2. All-weather fire dept. access roadway, minimum of 20 feet of unobstructed width, capable of supporting the imposed loads of 52,000 lb. Fire apparatus need to be provided to within 150 feet of all portions of the building prior to above grade constnaction. I7FC 97 8913. Fire lanes will need to be posted, "No ParkingFire Lane" with signs that meet City of Wheat Ridge Standards. ITFC 97 901.4.2. 2. Exits: The main exit doors if provided with key locking devices shall be provided with a sign stating," This Door Is To Remain Unlocked During Business Hours: ITI'C 97 12073 2. The remaining exit doors will need to be openable from the inside without the use of key of special lnowledge. LTFC 97 12073 . Page Two 3. Emergency Lighting: l. Emerjency lighting will be subject to field inspection. Additional units may be required. UFC 97 12ll .1 4. Second Floor Use: 1. Please provide information on the use of the second floor. 5. Service Bays: 1. Per the letter provided from Gary Bryan March 2, 1999 the service bays will be limited to the exchange of parts only. No open flames or welding will be used at the site. iJFC 97 Article 2. 2. Electrical receptacles will need to be installed a minimum of 18 inches above finished floor. iTFC 97 2902.4 3. Waste oil will need to be stored in approved containers or tanks. UFC 97 2901.6.2. 4. Oily rags and similar waste materials will need to be placed in metal containers with lids. iJFC 97 2901.73. 6. Need information on the types of oils, solvents, or flammable liquids that may be used or stored within the service 6ays. UFC 97 Article, 79 and 80. 6. Fire Extinguisher's: Fire extinguisher's shall be a minimum of a 4-A rated, 10-1b ABC dry chemical units, fully charged with current inspection tags, mounted not less than three feet nor more than five feet from the floor to the top of the mounting bracket at each exit door and at the top of the stairway to the second floor. . UFC 971002.1. Amended. 7. Carpeting: Carpeting shall be a minimum of a Class II Critical Radiant Flux and documentation shall be provided prior to installation. UFC 97 Appendix IV-A. Page Three 8. Additional Information: One hour fire resistive doors will need to be labeled, "Fire Door po Not ObstrucY" in a minimum of one inch letters. iJFC 97 1111.23. 2. Any code requirements arising from constriction will be addressed. 3. Twnety four hours notice required for all inspections. Inspections are conducted Tuesday thnx Friday. 9. Requests: 1. We would request that a foundation only permit be issued until all weather access is provided to within 150 feet of all portions of the building.. Sincerely, Arvada Fire Protection District Steve Ste gleder Deputy Fire Marshal 7500 West 29th Avenue The City of Wheat Ridge, Colorado 80215 Wheat Telephone 303/ 235-2868 Ridge FAX 303/235-2857 February 8, 1999 Mr. Robert Norick, P.E. Contra Engineering Inc. 8795 Ralston Road, Suite 240 Arvada, Colorado 80002 Re: Wheat Ridge Auto, 9208 West 44th'Aventte - Approval of Final Drainage Report, Grading & Erosiori Con£rol Plan Dear Mr. Norick, This letter is to inform you that the final drainage report, and the grading/erosion control plan for the above referenced project have been reviewed and approved for construction. Please be aware of the following items regarding the construction of the project: 1. The proposed drainage facilities shall be constructed and approved by the City of Wheat Ridge prior to issuance of the Certificate of Occupancy. 2. Erosion control for the project shall be placed in conformance with the approved drainage/erosion control plan and shall be maintained as needed during the course of construction. 3. All drainage improvements shall be constructed in conformance with the approved drainage report and plan. 4. It will be the responsibility of the contractor for the project to repair any damage to the existing public improvements on West 44th Avenue as a result of related construction traffic in the area. Also, the contractor will be responsible for maintaining West 44t° Avenue on a regular basis such that it is free of construction debris and tracking from construction traffic accessing the site. 5. Upon completion of the drainage improvements the engineer, Mr. Robert Norick, P.E., Contra Engineering, Inc. shall provide to the City of Wheat Ridge a letter of certification stating that the various improvements, as defined in the drainage report and plan, have been accurately surveyed to confirm that their construction is in accordance with these -`JEi-ARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 5940 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 9/30/97 7500 WEST 29TH AVENUE WHEATRIDGE, CO 80215 Property Owner : Property Address : 9205 44TH AV Contractor License No. : 19690 Company : D C Construction Phone: 986-8888 Phone : 403 8742 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsi ility t r compli ce with the Wheat Ridge Building Code (U.B.C.) and all other applicable W ~ge ordjrioe,d, for work under this permit. (OWNER)(CONTRACTOR) Description : DEMO BUI Construction Value : $0.00 Permit Fee : $10.00 Plan Review Fee : $0.00 Use Tax : $0.00 Total: $10.00 Electrical License No : Company: Plumbing License No : Company : Mechanicat License No : Company : Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: m m (i) This permit was issued in accordance with the provisions set forth in yopur application and is sub~ect to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Coloredo or any other applicable ordinances of t~e City. (2) This permit shall expire if (A) the work authorized is not commenced wiihin siuly (60) days from issue date or (B) the building authonzed is suspended or abandoned for a period of 120 days. (3) If th;s permi[ expires, a new permit may be acquired for a fee of one-half the amount normally required, provitletl no changes have been or will be made in the original pians and specifications antl any suspension or abandonment has not exceetled one (7) year. If chan9es are made or if suspension or abantlonment exceeds one (1) year, full fees shall he paid for a new permit. (4) No work of anymanner shall be done thatwill change the naturel flow of water causin9 a drainage problem. (5) Contractor shall notiry the euiltling Inspector iwenty-four (24) hours in advance for all inspections and shall receive written approval on inspec6on card before proceediing with successive phases of [he job. (6) The issuance of a permit or the approval of tlrawings and specifications shall not be construetl to be a permit for, nor an approval of, any violation of the provisions qFthe puilding co,des.or any qtqer ord'yiance, law, mle or regulafion. Inspector ~ 3 THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DFPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - Property Owner: 4a.9-t2 Property Address : o ~ bi, xR.v4da Contractor License No. : CompanY: 1~~C~~-~-•s~--e~~i~'-' Phone : ~S(, Phone: ~a03~~sL/i OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : I hereby certity that the setback distances proposed by lhis permit application are accurate, PBRiII[ FE2 : and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or easements or restrictions of record; that ali measurements shown, and allegations covenants Plan Review Fee : , made are accurate; that I have read and agree to abide by all conditions printed on this appliwtion, and that I assume full responsibility for compliance wilh the Wheat Ridge Building . Use Tax : Code (U.B.C.) and all other applicable Wh Ri ge ordJ/'ianc to ork nder this pertnit. DATE Total (OWNER)(CONTRACTOR) SIGNED Description A C BUILDING DEPARTMENT USE ONLY Z'onin~'~CoFriinefits~ SIC : Sq. Ft. : Approval: Zoning : Bu11Hin~'CO~ents:7 Approvai: Approvai: Occupancy : Walls : Roof : Stories : Residentia! Units : Electrical License No : Plumbing License No : Mechanical License No ; Company: Company: Company: Expiretion Date : Expiration Date : Expiration Date : Approval : Approval : Approval : im LPia-n3~Re'f~f~d~ 11 OPIa~RSqutr~l~ IN 029ftM~BaMIN (7) This permit was issued in accoNance with the provisions set lorth in yopur applicalion and is su6I'ect to the laws af the SWIe of Cobrado and to the Zoning RegulaGons and Building Code of NTeat Ridge. Colorado or any ather appliwble oMinances of the City. (2) This pertnit shall expire d(A) the work authonzed is nol commencetl wilhin siMy (60) tlays fmm issue dale or (B) the building aulhonzed Is suspended or abandoned for a perio0 of 7200ays. (3) If this pertnit e:pires, a new pertnil may be acquired for a fee of one-hall the artaunt nomulty required, provitled no changes have Deen or will be made in the original plans antl speuGwtions and any suspension or abanEOnment has rwl exceetled one (7) year. If changes are made or it suspension orabandonment exceeds one (1) year, (ull fees shall be paiE lor a new penniL (4) No work ol any manner shall be done ihat will change the nalural 0ow of water causing a drainage problem. (5) Cont2ctor shall notiy the Builtlinq Inspector hvenN-four (24) hours in advance for all inspeclions an0 shall receive vrtitlen approval on inspection wrd betore proceetliing vnU successive phases of the'ob. (6) Tl~e issuance ol a pertnit or Ihe approval ofid2wings an0 specififalions shall not be mnsWed to be a pertnil lor, nor an approvaf of, any violaGon of the provisions of the building codes or any other oNinance, law, mle or regulaUOn. - Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL• 234-5933 24 HOURS PRIOR TO INSPECTION 7500 WEST 29TH AVENUE • WHEAT RIDGE, COLORADO 80215 July 23, 1998 Mr. Robert Norick, P.E. Contra Ltd. 8795 Ralston Road, Ste 240 Arvada, Colorado 80002 TheCityof 4E ~Wheat ~Ridge Re: Wheat Ridge Auto, 9205 West 44t'` Avenue - First Review Comments of Final Drainage Study/Plan Dear Mr. Norick, I have completed the first review of the above referenced documents for the Wheat Ridge Auto project received on July 16, 1998, and have the following comments: Drainage Study (Discussion) Page 2-Proposed Drainage System 1. Please provide discussion regarding the detention volumes required and provided for ponds 1 and 2. Drainage Plan(s) 1. Please note more clearly the 100-year limits of ponding for both pond 1 and 2. 2. Please provide concise typical details for all storm sewer structures proposed. 3. Please note the 100-year volume provided for ponds 1 and 2. 4. Please provide typical cross sectibn details for the north and east property lines to confirm appropriate grades to adjacent properties. 5. Please provide a detail of the proposed 5-foot manhole, including.tie-in method(s) for piping into the manhoTe. (303) 234•5900 • ADMINISTRATION FAX: 234-5924 • POLICE DEPARTMENT FAX: 235-2949 Mr. Robert Norick, P.E. Contra, Ltd. Page 3 Please return all red-lined prints with the second submittal. have any questions, please contact me at 235=2868. Sely, IP77;,v udson, M.P.A. Greg Development Review Engineer cc: Dave Kotecki, Sr. Project Engineer Steve Nguyen, Traffic Engineer John McGuire, City Surveyor Meredith Reckert, Sr. Planner File 1> > 1 1 AltPrnative Homes farYouth hiResidential Care and Treatment for Troubled Youth and Families. ~pGE rkTv OF WHL:aT R February 6, 1998 VVI City of Wheat Ridge , ~ D~';i~~P~9EJ~T Planning Deparhnent ( ~?LANNlftG 7500 West 29th Avenue ~ Wheat Ridge, CO 80219 Subject: Site compliance of Building Permit Issued Properiy Address: 9207 West 44th Avenue In my last conversation with planning personnel, I got the impression that standards for set backs in commercial zones that are not zone districts allowing residential uses would not be enforced between 9207 West 44th Avenue and other commercially zoned properties. Ourproperty at 9201 West 44th Avenue is zoned commercial, but we purchased it because the zoning regulations allow residential uses for treatment centers which are a part of our business. The building is a converted residential shucture built in 1927. Not enforcing set backs for "residential uses" will do irreparable harm to the use and value of our building. Please review any site plans for 9207 West 44th Avenue with us prior to any official J approval in hopes we can avert conflict or lawsuits with the City and the owne X. Sincerely, ~ ~ Eldon R.: Holland _ Executive Director ERH:ddt - for Children c~ eP niemne.Asemr Nationel Association of Homes and Secvices ~ ~ 0~y-,~ w ~ 9201 W. 44th Avenue • 4Vheat Ridge, CO 80033 •(303) 940-5540 • FAX (303) 940-5542