June 17, 2021 Subject : Structural Certification for Proposed Residential Solar Installation Job Number: 501R-022SCH1; Rev Al Client: Joe Schieffelin Address: 10022 W 31 St Ave, Wheat Ridge, CO, 80215 Attn: To Whom It May Concern sunrunAstra CAT 1 OPPp O L/C,,, Ov NEW .•• �� 537891 NAI. Digitally Signed on: 6/17/2021 A field observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: • 2018 1 RC/I BC/I EBC, ASCE 7-16 & 2018 N DS • Basic Wind Speed V = 107 mph, Exposure C • Ground Snow Load = 30 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summary (Hardware Check Includes Uplift Check on Attachments/Fastener, Structure Check Considers Main Structure) AR -01 Orientation Attachment Spacing/Cantilever Configuration GoverniDCRng Result Landscape 72/27 Staggered 43% Portrait 48/22 Staggered 36% Pass Pass Roofing Material Pitch Structure Check Comp Shingle 19° Pass 225 Bush St. Suite 1400 San Francisco, CA 94104 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION • SYSTEM SIZE: 476OW DC, 406OW AC • MODULES: (14) JA SOLAR: JAMBOS10-340/MR • ALL WORK SHALL COMPLY WITH 2018 IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SOLAR MODULES SE SERVICE ENTRANCE RAIL PV -1.0 COVER SHEET PV -2.0 SITE PLAN • INVERTERS: (14) ENPHASE ENERGY: IQ7PLUS-72-2-US • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. • RACKING: SNAPNRACK SERIES UR40; ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING SNR -DC -00438 • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. MP MAIN PANEL PV -3.0 LAYOUT PV -3.1 MOUNTING DETAIL • MAIN PANEL REPLACEMENT: EXISTING 70 AMP MAIN PANEL WITH 70 AMP MAIN BREAKER TO BE REPLACED WITH NEW , PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY STANDOFFS & 150 AMP MAIN PANEL WITH 150 AMP MAIN BREAKER. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. SP SUB -PANEL FOOTINGS PV -3.2 STRUC. UPGRADES ELECTRICAL • STRUCTURAL UPGRADES REQUIRED ON AR -01. THE PURLINPV-4.0 'MODULES CONFORM TO AND ARE LISTED UNDER UL 1703/61730 PV -5.0 SIGNAGE SUPPORT MUST BE EXTENDED TO THE FULL LENGTH OF LC PV LOAD CENTER ® CHIMNEY THE ROOM. SEE DETAIL • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. �6 City of • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. SM SUNRUN METER ATTIC VENT p, W heat R d� /COMMUNITY DI VELUPMENT • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II 0 FLUSH ATTIC VENT MODULES, ARE CLASS A FIRE RATED. PM DEDICATED PV METER APPROVED o PVC PIPE VENT • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL Reviewed for Cade Compliance CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). INV INVERTER(S) ® METAL PIPE VENT u � •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). ® T -VENT AC Plans Examiner Date • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. AC DISCONNECT(S) 1-1SATELLITE DISH VNN of e,mH:yhels•amue ofoanmRa apprawl oJpkns uermnom .deompumboos �roNmB Wu PermNJa, am app ulaJ, ay.lhmm my of Me wovi;Rlm of Me bell code a of cry city ardor ,. Pel •10.46 AMPS MODULE SHORT CIRCUIT CURRENT. 0 DC DISCONNECT(S) FIRE SETBACKS coda m9 m pne OUNklrltyea waxy ammel mepmwslans of NN, aoydug mdKarounaayWrne�xr,�aamwwxd • 16.34 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. • PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2).CB IQ COMBINER BOX HARDSCAPE CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION F_ —1 INTERIOR EQUIPMENT — PL— PROPERTY LINE J SHOWN AS DASHED SCALE: NTS Approval Notes: 1) P/V array system to have grounding system installed per Part III of s u n r u n A AMPERE Article 250 per 2017 NEC Article 690.47(A). AC ALTERNATING CURRENT 2) If UFER ground in not available provide orverify supplemental ground rods per 2017 NEC Article 250.53(A)(3). AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP 3) Natural Gas & Cold Water bonding per 2017 NEC Article 250.104(8) COMP COMPOSITION EC #7080, ME #600088 DC DIRECT CURRENT - -_ (E) EXISTING emwsmHAW.MVeon,comooz © A qualified person must be present at the time of a PV electrical inspection S ENERGY SYSTEM EXT PHONE Will FM0 ,. s.�� EXT L- 1) Licensed master or electrician, INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC JOE SCHIEFFELIN 6A� 2) Residential wireman MSP MAIN SERVICE PANEL 10022 W 31 STAVE, WHEAT (N) NEW RIDGE, CO, 80215 "1 3) NABCEP-certified solar installer capable of testing the rapid shut down system. NTS NOT TO SCALE OC ON CENTER TEL. (303) 4835197 PRE -FAB PRE -FABRICATED APWTMK#:APN:48613 - - - PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC PROJECT NUMBER: •ioozs wa1sLR, wheal Ridge, CO R021 oi RSD RAPID SHUTDOWN DEVICE 501 R-022SCHI Funeral cre'FauaF. a TL TL TRANSFORMERLESS 415 580E920 ex3 DESIGNER: ( ) cemele`y. TYP TYPICAL V VOLTS LUKE HOLMES 11111pa,L W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV: A 6/17/2021 PAGE PV -1.0 SITE PLAN - SCALE =1/16" = 1' ROOF PATHWAYS (3' TYP) W 31 ST AVE of of of of of 9 PL NOTE: MICRO -INVERTERS INSTALLED UNDER EACH MODULE PL PL PL PL J a ROOF PATHWAYS (3' TYP) NOTES: • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: • TOTAL ROOF SURFACE AREA: 2767 SQFT. • TOTAL PV ARRAY AREA: 253.5 SQ FT. • PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 = 9.2% ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD: 3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD: 30 PSF WIND SPEED: 107 MPH 3 -SEC GUST. AR -01 COMP SHINGLE - UR 1 -Story 2X6 RAFTERS 9' - 11" 24" ULTRA RAIL SPEEDSEAL FOOT, SEE 6' - 0" 2' - 3" 4' - 0" 1' - 10" STAGGERED DRAWING SNR -DC -00438 S.S. LAG SCREWS: D1 - AR -01 - SCALE: 1/8" = 1'-0"5/16": 2.5" MIN EMBEDMENT STRUCTURAL NOTES: PITCH: 19° • INSTALLERS SHALL NOTIFY AZIM: 180° ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY (EXCLUDING — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1 SKIRT) IS WITHIN 12" 30'-8" I BOUNDARY REGION OF ANY 7'-5" I ROOF PLANE EDGES � (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ❑ Li I ADDED AND OVERHANG 5'-i 0" I REDUCED WITHIN THE 12" 3'-311 ❑ I BOUNDARY REGION ONLY AS I O o - ., i •• ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY o I 11 o o •• ALLOWABLE OVERHANG INDICATED ON PLANS TO 4' TYP - I BE 1/5TH OF ALLOWABLE o o I ATTACHMENT SPACING l I INDICATED ON PLANS 2'-9" 3' 18'4" 23'-1 " — 30' -5" ---------------- sunrun -----------------------------------------j EC #7080, ME #600088 1 PURLIN REQUIRED ACROSS 5525E 58TH AVE, ARVADA, C060002 PHONE 805.540.7631 Pv-s.z ENTIRE ROOF FAX CUSTOMER RESIDENCE: L/L,� JOE SCHIEFFELIN PPp0 O.••••W•, 2 W 31 ST AVE, WHEAT city af GE, CO, 80215 f 53789 = TEL. 303) 483-5197 p0 ;..• MK #: APN: 48613 ••• •''•• �F ............ OJECT NUMBER: `rs/pkgLE� 501 R-022SCHI Digitally Signed: 06/17/21 DESIGNER: (415) 580-6920 ex3 LUKE HOLMES SHEET LAYOUT REV: A 6/17/2021 PAGE PV -3.0 SNAPNRACK UR SPEEDSEAL FOOT FOR COMPOSTION ROOF MOUNTING REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. 5/16" 0 S.S. LAG SCREW MUST EMBED A MIN. OF 2-1/2" INTO STRUCTURAL MEMBER REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5/16" 0 HARDWARE TORQUE SPECIFICATIONS RAIL IS MOUNTED ON THE DOWNSLOPE SIDE OF THE SPEEDFOOT SNAPNRACK, ULTRA RAIL MOUNT, TAPPED SNAPNRACK ULTRA RAIL MOUNT. THRU MODULE HEIGHT OFF ROOF, RANGE: UR -40: 3-3/8" - 4-3/8" / UR -60:4" - 5" ULTRA RAIL 2-1/2" MIN. EMBEDMENT INTO WOOD MEMBER UR SPEEDSEAL FOOT SNAPNRACK, 5/16"0 S.S. LAG SCREW, TYP. PENETRATION DETAIL COIL SPRING FOR 3/8"0 BOLT. S.S. SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING 2-1/4" 5/16"0-18 X 2" BOLT, SERRATED FLANGE, S.S. SEALANT ROOF DECKING SHINGLE ROOFING, TYP. BIN: 8 DECKING, TYP. REVISION: J- 311=020 NEW DETAIL MJA_ 2- 6/5/2020 DIE CAST RDP $7/22/2020 NAME UPDATE MJA STRUCUTRAL MEMBER, WOOD RAFTER, TYP. S.S. (MAY INCLUDE TYPE GASKET) CAVITY IN SPEEDSEAL FOOT IS FILLED WITH SEALANT TO ENCAPSULATE AND PROTECT THE ROOF PENETRATION FROM MOISTURE sunrun EC #7080, ME #600088 5625 W 50TH AVE. MVAOq CO 80002 PHONE 805.510.'/081 FA 0 CUSTOMER RESIDENCE: JOE SCHIEFFELIN 10022 W 31 STAVE, WHEAT RIDGE, CO, 80215 Pip L/O Nr1E7y x'1'41 r z9�sP �o TEL. (303) 483-5197 APN/TMK #: APN: 48613 PROJECT NUMBER: 45677 501R-022SCHI EXP. W/31/=0 of LU DESIGNER: (415) 580-6920 ex3 A AI LUKE HOLMES URRAIL URRAIL STRUCTURAL MEMBER (RAFTER) SHEET FOR USE WITH SNAPNRACK ULTRA SERIES RAILS MOUNTING DETAIL \ n Sunrun South LLC DESIGNER: M. AFFENTRANGER SCALE: DNS DRAWING NUMBER: DESCRIPTION: REV: REV: A 6/17/2021 lll\\VII W/I ���� ���n .ate*.�aa�a amolq «.+�� »«»Ea+aa F a+ate DRAFTER: M. AFFENTRANGER SNR -DC -00438 ULTRA RAIL, ATTACHMENT DETAIL, PAGE °° = "�;R„„' DATE: 7/22/2020 SPEEDSEAL FOOT TO RAFTER PV -3.1 Solar Mounting Solutions , ,;� APPROVED BY: B. PETERSON PURLIN REINFORCEMENT ELEVATION PV -3.2 SCALE: NTS ACCEPTABLE MIN. LUMBER TYPE LUMBER TYPE MIN. Fb (psi) DOUG FIR -LARCH #2 900 SOUTHERN PINE #1 1500 HEM -FIR #2 850 SPRUCE PINE FIR #2 875 (N) 2x6 PURLIN REINFORCEMENT W/ (5) 10d COMMON END NAILS TO (E) PURLIN SUPPORT. 10d COMMON FN @ 6" OC NAILED TO (E) PURLIN. SPLICE OF (N) 2x4 TO OCCUR AT VERTICAL SUPPORT. RAFTER E) PURLIN sunrun (E) PURLIN SUPPORT EC #7080, ME #600088 (E) CEILING 5525 W 56TH AVE, ARVADA, CO 80002 PHONE 805.540.7631 JOIST FAX 0 (E) LOAD CUSTOMER RESIDENCE: BEARING WALL PPG L/C JOE SCHIEFFELIN O..F 2 W 31 ST AVE, WHEAT W•. GE, CO, 80215 BSECTION 53789 i TEL. 303) 483-5197 SCALE: NTS -v 1P :..• MK#:APN: 48613 �F OJECT NUMBER: `rS/OkgL•E'501 R-022SCHI Digitally Signed: 06/17/21 DESIGNER: (415) 580-6920 ex3 LUKE HOLMES SHEET STRUC. UPGRADES REV: A 6/17/2021 PAGE PV -3.2 120/240 VAC SINGLE PHASE SERVICE UTILITY O GRID C1 T METER #: XCEL D1048163 NEW 150A MAIN BREAKER (END FED) NEW 150A MAIN PANEL FACILITY LOADS FA UW (N)25A -DRDURD PV BREAKER AT OPPOSITE END OFBUSBAR (N) 125A ENPHASE IQ AC COMBINER BOX WITH INTEGRATED 10A ENVOY BREAKER 3CX-IQ-AM1-240-3C 20A BREAKER [A] 20A BREAKER [B] Approval Notes: 1) P/V array system to have grounding system installed per Part III of Article 250 per 2020 NEC Article 690.47(A). 2) If UFER ground in not available provide or verify supplemental ground rods per 2020 NEC Article 250.53(A)(3). 3) Cold & Hot Water & Natural Gas bonding per 2020 NEC Article 250.104(A)(B) (14) JA SOLAR: JAM60S10-3401MR MODULES (1�1r1Nl rl�l AND MICRO -INVERTER PAIRS (14) ENPHASE ENERGY: I07PLUS-72-2-US JUNCTION BOX �, 1 BRANCH OF (7) OR EQUIVALENT 1 MICRO -INVERTERS [A] (1) BRANCH OF (7) MICRO -INVERTERS [B] CONDUIT SCHEDULE OPEN CIRCUIT VOLTAGE: # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 8 AWG THHN/THWWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 MODULE CHARACTERISTICS JA SOLAR: JAM60S10-340/MR: 340 W OPEN CIRCUIT VOLTAGE: 41.55 V MAX POWER VOLTAGE: 34.73 V SHORT CIRCUIT CURRENT: 10.46 A GENERAL NOTES: • FIELD SPLICE WIRE TO APPROPRIATE SIZE FOR MANUFACTURE TERMINATION SPECIFICATIONS WHEN NEEDED. • WIRE UPSIZE AT TIME OF INSTALLATION IS PERMISSIBLE. • CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN BREAKER IN MAIN PANEL ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED. • MAIN PANEL REPLACEMENT: EXISTING 70 AMP MAIN PANEL WITH 70 AMP MAIN BREAKER TO BE REPLACED WITH NEW 150 AMP MAIN PANEL WITH 150 AMP MAIN BREAKER. &WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B) OWARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C) &WARNINdr POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: OWARNING PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(D)(2)(3)(c) LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54 LABEL LOCATION: INSTALLED WITHIN T OF RAPID SHUT DOWN SWITCH PER CODE(S): NEC 2020:690.56(C)(2), IFC 2012:605.11.1, IFC 2018:1204.5.3 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C) NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21 (B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN SOLAR PANELS AND MICROINVERTERS ON ROOF SERVICE ENTRANCE AND PV BREAKER DISCONNECT 'RAPID SHUTDOWN' PV LOAD CENTER 10022 W 31ST AVE, WHEAT RIDGE, CO, 80215 PER CODE(S): NEC 2020: 705.10, 710.10 From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: Solar PV Installation Date: Friday, June 18, 2021 1:34:30 PM Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes Solar PV Installation? PROPERTY INFORMATION Property Address 10022 W 31st Ave Wheat Ridge CO 80215 Property Owner Name Joe Schieffelin Property Owner Phone 303-483-5197 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email joeschief58@gmail.com Address Attach City of Wheat Wheat Ridae Buildina Electronic Payment Form.odf Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTRACTOR INFORMATION Contractor Business Sunrun Installation Services Inc Name Wheat Ridge 070159 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-942-8074 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email colorado.permitting@sunrun.com Address Retype Contractor colorado.permitting@sunrun.com Email Address DESCRIPTION OF WORK Scope of Work Roof Mount, Flush Mount, Grid -Tied 4.76kW Solar PV KW 4.76 # of Panels 14 Location of Panels South House Roof Structural required Yes Upload engineer letter PE Letter 10022 W31stAve Schieffelin. Joe RevA.Ddf or pages on 8 1/2" x 11" only Solar Installation Plan PV Plans 10022 W31stAve Schieffelin. Joe RevA.Ddf Set on 11'x17" only. Project Value (contract 9044 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Erik Roth Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. 1* � � i City of Wheat Ridge Residential Solar PERMIT - 202101310 PERMIT NO: 202101310 ISSUED: 06/21/2021 JOB ADDRESS: 10022 W 31st Ave EXPIRES: 06/21/2022 JOB DESCRIPTION: Roof Mount, Flush Mount, Grid -Tied 4.76kW Solar PV 14 panels *** CONTACTS *** OWNER (303)483-5197 JOSEPH W SCHIEFFELIN & CARI B SUB (303)577-9628 THOMAS BROOK 070159 SUNRUN INSTALLATION SRVS. INC. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2404 / APPLEWOOD KNOLLS, PARAMOUNT HE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 91044.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications, applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/21/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge E -Res. Electrical Service PERMIT - 202101312 PERMIT NO: 202101312 ISSUED: 06/18/2021 JOB ADDRESS: 10022 W 31st Ave EXPIRES: 06/18/2022 JOB DESCRIPTION: Electrical service upgrade on (S) exterior house of 150 AMPS *** CONTACTS *** OWNER (303)483-5197 JOSEPH W SCHIEFFELIN & CARI B SUB (303)577-9628 THOMAS BROOK 070159 SUNRUN INSTALLATION SRVS. INC. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2404 / APPLEWOOD KNOLLS, PARAMOUNT HE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11750.00 FEES Total Valuation 0.00 Use Tax 36.75 Permit Fee 70.70 ** TOTAL ** 107.45 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. 1* � � i City of Wheat Ridge E -Res. Electrical Service PERMIT - 202101312 PERMIT NO: 202101312 ISSUED: 06/18/2021 JOB ADDRESS: 10022 W 31st Ave EXPIRES: 06/18/2022 JOB DESCRIPTION: Electrical service upgrade on (S) exterior house of 150 AMPS I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any pplicab e code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/18/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Electrical Service Change/Upgrade/Electrical Work Permit Application Date: Friday, June 18, 2021 1:39:13 PM Electrical Service Change/Upgrade/Electrical Work Permit Application This application is exclusively for RESIDENTIAL ELECTRICAL SERVICE CHANGE OR UPGRADE (200 amps or less). YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes electrical service change or upgrade - 200 amps or less? PROPERTY INFORMATION Is this Residential or Residential Commercial? Property Address 10022 W 31st Ave Wheat Ridge CO 80215 Property Owner Name Joe Schieffelin Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 303-483-5197 CONTRACTOR INFORMATION Contractor Business Sunrun Installation Services Inc Name Contractor's License 070159 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-942-8094 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email colorado.permitting@sunrun.com Address Retype Contractor colorado.permitting@sunrun.com Email Address DESCRIPTION OF WORK Is this an electrical Change service upgrade or change? Number of Amps 150 Location of work South Exterior House (garage, house, etc) Provide additional n/a details, if needed. Project Value (contract 1500 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Andrew Nyman Permit Email not displaying correctly? View it in your browser. City of Wheat Ridge Residential Roofing PERMIT - 201701612 PERMIT NO: 201701612 ISSUED: 06/06/2017 JOB ADDRESS: -I'IT022 W 31st AVE EXPIRES: 06/06/2018 JOB DESCRIPTION: Remove and replace 30 squares roof with Certainteed Presidential shake IR *** CONTACTS *** OWNER (303)483-5197 SCHIEFFELIN JOSEPH W SUB (303)993-6057 Adam Steinbach 100332 Precision Homes *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2404 / APPLEWOOD KNOLLS, PARAMOUNT HE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,754.35 FEES Total Valuation 0.00 Use Tax 204.84 Permit Fee 204.30 ** TOTAL ** 409.14 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€I"s installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. L�1'ype INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Date Inspector Initials Comments Concrete Encased Ground (CEG) dplain Inspection (if applicable) Foundation / P.E. Letter Electrical Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections � E-lectrical Date Inspector Initials Comments Sewer Service dplain Inspection (if applicable) Plumbing Electrical Do Not Cover Underaround or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing dplain Inspection (if applicable) ispection / Fire Protection Dist. Electrical 'olid -Roof (; Aechanical Lath / Wall Tie h,--eF 1indow/Doors Rough Electric uilding dough Plumbing/Gas Line tough Mechanical lough Framing ough Grading ,sulation ywall Screw / Nail n n. Inspections Date Inspector Initials Comments jcaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. & Drainage / Public Works Dept. dplain Inspection (if applicable) ispection / Fire Protection Dist. Electrical ')lumbing Aechanical h,--eF 1indow/Doors uilding All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate 1pancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage ilding Division. pection Time Window — Please email InSptlmerequeSt@ci.Wheatridge.co.US by 8:00 A.M. the morning of the 2 with the property address in the subject line of the email. Time window is based on the inspector's route. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather i CITY OF WHEAT RIDGE - Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: /"'�� ❑ No one available for rYe tion: Tim ��� AM/PM Re -Inspection requiredNo When corrections have been made, call for re-ins//p ti n 303-234-5933 f / Date: V 2 7 Y _ 17 Inspector: DO NOT REMOVE TIHIS NOTICE � ► 4 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: /43: Job Address: 100D -->- O (9-R Permit Number: 0 I i X) �D 12 (6 tJ OT STrVIKA 1 L OA r) �O9 (/�l (, ro") q 6AI 12 1 A/-" ❑ No one available for inspecti n: Time % AM Re -Inspection require Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: / Inspector: DO NOT REMOVE THIS N TICE City of Wheat Ridge Residential Roofing PERMIT - 201701612 PERMIT NO: 201701612 ISSUED: 06/06/2017 JOB ADDRESS: 10022 W 31st AVE EXPIRES: 06/06/2018 JOB DESCRIPTION: Remove and replace 30 squares roof with Certainteed Presidential shake IR *** CONTACTS *** OWNER (303)483-5197 SCHIEFFELIN JOSEPH W SUB (303)993-6057 Adam Steinbach 100332 Precision Homes *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2404 / APPLEWOOD KNOLLS, PARAMOUNT HE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,754.35 FEES Total Valuation 0.00 Use Tax 204.84 Permit Fee 204.30 ** TOTAL ** 409.14 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€'"'s installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION City of Wheat Ridge Residential Roofing PERMIT - 201701612 201701612 ISSUED: 06/06/2017 10022 W 31st AVE EXPIRES: 06/06/2018 Remove and replace 30 squares roof with Certainteed Presidential shake IR I, by my signature, do hereby attest that the work 0bper shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I amie legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, tees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any, manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspe ion Services Division in accordance with established policy of all required inspections and shall rnifptceed or co or it ut written approval of such work from the Building and Inspection Services Division...p 6, The issuance or grantingbf� shall not be cons ` d to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. I FOR OFFICE USE ONLY I I City of Date: f)�;O'Wh6at C d -=''COMMUNrry DEVELOPVk!E3Nr1rS" pt'n1ponnit# )o Building A Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Plan Review Fee., Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Inmriplete applications may not be processed. *** Property Address: rs�- Property Owner (Pleaseprin Pharr Property Owner Email;, Mailing Address: (if different than property address) Address: SG-ryk-z City, State, Zip: Architect/Engineer E-mail: Phone: Contractor. ADr-euc' I Contractors City License #.- ( Phone: -(q20512 Contractor E-mail Address: Electrical: Plumbing: Mechanical: W, R. City License# WR City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form Q COMMERCIAL RESIDENTIAL i escriphon of work: (Check all that apply) (3 NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE COMMERCIAL ROOFING COMMERCIAL ADDITION RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) (� MECHANICAL SYSTEWAPPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT OTHER (Describe) (For ALL projects, please provide a d at1I1od description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed neer condition, appliance size and efficiency, type and amount of materials to be used, etc,.) � CSS � e pLcoac Sq. FULP Btu's Gallons Squares Ise . Protect Value: (Contract value or the cast of all materials and labor included in the entire project) gJ54- • � ONNNERiCONTRACTQR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations ofthe City of Wheat Ridge or covenants, easements or restrictions of record, that all measurements shown and allegations made are accurate, that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with applicable City of Wheat Badge codes and ordinances for work under any permit issued based on this application, that i am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application taJim�y on this application. CIRCLE ONE. (0if'N fCONTRACTi7R) a (AUTHORIZED REPRESENTAM'E) of (Olf-VER) (C'C?A�7RACTOR) IN Nor �LQ?UTq Y)p L SIGNATURE: _ � I A4TE: LP DEPARTMIENT USE ONLY ZONING Gt3t sAAiAFFT M OCCUPANCY CLASStFICfaT+ON Review TYPE OF CONST%UC71ON: SPRfNKLERW_ MOLDING t?tSPARTMtrt . COMMPENTS 0eicLAPANT LOAD Reviewer Pt#JC WORKS x^,G3MdivtENTII& Reviewer t'�MLS§LQ FQFtMS Fire Depattntem DRecai,,ea 0 plot Required Water District [I Received ®loot Required Sanitation District 13 Received D blot Required Building Division Valuation: i CITY OF WHEAT RIDGE Building Inspection Division 0000 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax j a a s INSPECTION NOTICE t Inspection Type: D Job Address: Permit Number:(�- a N Pe go u-eo S ❑ No one available for inspection: Time ..'Z (JAM/PM Re -inspection required:es No I I When corrections have been made, call for re -inspection at 303-234-5933 A Date: ! Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: � flo Job Address: 1607-.2- lac/ 3 / so A V� J"No one available for inspection: Time ``4'' AM/PM Re -Inspection required: 1Yes) No When corrections have been made, call for re -inspection at 303-234-5933 Date: �'r � � '� ` Inspector: i, DO NOT REMOVE THIS NOTICE ,14 No one available for inspection: Time Y,`> C--' AM/PM V1 A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 01 :r t) Job Address: 160,2 a L -)SJ �ye- Permit Number: oZ O 1 7 D l 6 1 Kin 1, cx A A e r- Pon , (c: .b (_p C,/ t e Lj Q_ A jF rt-, !A` 5 -I- r t, -i- Re-Inspection required:,/ Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: l3 0l f % Inspector: U v DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: � Ur Job Address: l oozz w Permit Number: 2 % 014 00,LIt C Y ❑ No one available for inspection: Time/PM Re -Inspection required: Yes Nq When correctionshave been made, call for re -inspection at 303-234-5933 Date::7 L1017Inspector: /-f DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: � Ur Job Address: WoZZ W W -61 -If Permit �/f Number: ` -// 7 OIL I o. ( I ' cb--r A040ZLI1 T- K 1 Ij Vr ❑ No one available for inspection: Time ;AIS mm Re -Inspection required: Yes N' When corrections have been made, call for re -inspection at 303 -234 - Date: 3 Ll 017 Inspector: k n. DO NOT REMOVE THIS NOTICE INSPECTION RECORD Occupancy/Type INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day.'; - -- - P INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS ..COMMENTS: Footings /Caissons Stemwall / (CEG) Concrete '. Encased Ground '- Reinforcing or Monolithic Weatherproof /.French Drain Sewer Service Lines Water Service Lines INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) DO NOT POUR FLOOR UNTIL :ABOVE HAS BEEN SIGNED ROUGHS Sheathin HRoughElectric ll tie Service ', ectric mbing g chanical AB OVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING' Framing Insulation Drywall .Screw FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W &:Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking "& Landscaping " * NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY 'BSISSUED.'. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY.:. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER ♦ i CITY OF WHEAT RIDGE r Building Inspection Division I I (303) 234 -5933 Inspection line (303) 235 -2855 Office (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: r N19 Job Address: 1062 dJe57P Permit Number: !v -l26d ❑ No one available for inspection: Time V: 1 i AM/M Re- Inspection required Yes )No When corrections have been made, call for re- inspection at 303-234-5933 Date: -s ' 26 /v Inspector: /3 DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234,5933 inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: rnjA L 12413E , Ioh Address 1t7 0- Av Permit Number: 1 ) }'4'. l.3' /zoo / ,- _5'/a t n My 2 Gt t/ l G i ,��'2 (Z� ' ®i �f - '� 5�474�77S' -P.l_'L G �i No one available for inspection: Time 2 AM /6 Re- Inspection required: Yes No When corrections have been made, cab for re inspection at 303 Date: S 2/ J6 Inspector: ley DO NOT REMOVE THIS NOTICE S •" Cit of Wheat Rid ., Y e g 1 \VlllttV1141({l 1 \V VLlll� 1 i/ 1�1[lll iVli/V 1' y m N PERMIT NO: 101261 ISSUED: 05/17/2010 JOB ADDRESS: 10022..W 31ST AVE EXPIRES: 11/13/2010 DESCRIPTION:: T /o: Install 30.5 sqs Ypres shake IR; I /W; ;& flashing. * ** CONTACTS * ** owner 303/234-9013 Joe.: Schreffelin go 303/462-3745 MARY PHILLIPS 08-0034 O'CONNOR ROOFING x. w * *PARCEL "INFO ** %? ZONE iCODE: UA ': USE: UA �- SUBDIVISION:: 0675 BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED 'PROJECT .VALUATION: 14,542.00 FEES " Permit Fee 326.70 Total Valuation .00 Use ':Tax 261.76 � � ** TOTAL * *' 588.46 `Conditions: nails per :shingle is required. Ice dam membrane is required from eave edge to ' 2' inside exterior walls. Board sheathing with any gap greater than 1/2 .,requires panel sheathing overlay on entire roof. Sheathing inspection is -.:required prior to covering. j`Midroof! inspection is not required on permits . , purchased after 4/18/10. Contractor shall provide ladder for inspections.'. ; INSPECTION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 4 / 0 1 FW Building Permit Application Date: Plan #: Perntit #: RM. s !' lam � /& & Property Owner (please prino M - ) JL –S�i c 6P A/ =xE!1x/t Phone: L.M— � Mailing Address: (if different than property address) Address: j 0 g -J' ? '' , ContractorUcense #: 6)9'0D3-'-'1 Phone: Electrical City License #: Plumbing City License #: Mechanical City License #: Company: Company Company: Exp, Date: Exp. Date: Exp. Date: Approval Approval: Approval: Use Of space (description): Construction Value: :$ fas calculated per the Suit p Valoa6on Data sheep Plan Review (due at time of submittal): $ .{o- s�rrnCe �QafaxC� �rKcFG�rr /at'.G� /// u r ei. Sq. Ft./L.Ftadded: Squar BTU's Gallons Amps AGREEMENT 3ptication are accurate, and do not violate applicable ordinances; cents or restrictions of record; that all measurements shown, and ry all - conditions printed on this application and that 1 assume full 8.C) and all other applicable Wheat Ridge Ordinances, for work CIRLCE.ONE- (OWNE (C TRACTOR) or PERSONAL REPRESS ATIVE of (OW NTRA (COTOR) PRINT.NAME C1 SIGNATURE: ZONING COMMENTS: Zoning: Reviewer. DEPARTMENT USE ONLY OCCUPANCY- City of Ylq> Ridge Building Division 7500;IN�' Qve. Wheat Ridge, CO 80033 Office: 3:03-235 -2855 Fax: 303 - 235 -2857 Inspection Line: 303- 234 -5933 'I. _Bldg. Valuation: $ 1 0 Certificate of Completion AND/OR Compliance CITY OF WHEAT RIDGE 7500 W. 29TH AVENUE WHEAT RIDGE, COLORADO 80215 THIS CERTIFICATE VERIFIES THAT THE PROPERTY DESCRIBED BELOW, DOES COMPLY WITH THE WHEAT RIDGE BUILDING CODE, ZONING AND OTHER RELATED LAND USE AND DEVELOPMENT LAWS OF THE CITY OF WHEAT RIDGE FOR THE FOLLOWING PURPOSE. PERMIT # 13900 Single Family Addition OWNER: Joe & Cari Schieffelin ADDRESS: 10022 W. 31s` Avenue PROPERTY ADDRESS: 10022 W. 31s` Ave., Wheat Ri2e, CO 80033 CONTRACTOR: Homeowner DATE 11/13/2002 CHIEF BLTII,DING OFF ZONING ADMINISTRA D INSPECTIONS WILL NOT BE IMADE UNLESS THIS CARD IS POSTED ON THE BUILDING SITE 24 HOURS NOTICE REQUIRED FOR INSPECTIONS WHEAT RIDGE, COLORADO 7500 WEST 29th AVENUE (303) 234-5933 INSPECTION RECORD 2~ n JOB ADDRESS ~n a. a I i._) 51 ~/~l-rc-.-, BUILDING PE\RMIT N0. I "~?4 00_ 1 DATE ISSUED ~ ~ TYPE OCCUPANCY OWNER CONTRACTOR SETBACKSFROM PROPERTYLINES: NORTH SOUTH EAST WEST INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB INSPECTION DATE INSPECTOR Foundations Footings G $ oz ~ Caissons Reinforcing or Monolithic CA4-, p O;L ~ Weatherproofing Q POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED I Electrical Plumbing (Ground Work) Heating (Ground Work) DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED x ~ Rough Electrical 8 - z-8"^ Rough Plumbing Air Test Gas Piping Rough Heating & Ventilation Ok- ' (above must be signed prior to framing inspection) ~ 0 ~ Framing Insulatio Drywatl o"' ~ Zq Roofing Refrigeration Electrical underground Final Electrical T-: 7 ' o ~ Plumbin Heatin & Ventilation v•l i ;4 G Frame a. ~C 41 R.O.W. & Drainage Fire Department Parking & Landscaping ~ ~ ~ r; \ . OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM=°FIE WEATHER , DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 13900 BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE Date : 5/21/02 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner: JOE AND CARI SCHIEFFELIN Property Address : 10022 W 31 ST AVE Phone : 234-9013 Contractor License No. : Company : Phone : OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurete, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordi an e, for work under this permit. (OWNER)(CONTR4CTOR) SIGNED DATE J ~"I Z- Construction Value : $3,000.00 Permit Fee : $83.25 Plan Review Fee : $0.00 Use Tax : $60.00 Total: $143.25 Use: Description : 4' X 9' ADDITION TO EATING AREA OF KITCHEN ON FRONT OF HOUSE, BUT CHANGING NO ROOF LINES NOR EXPANDING HOUSE FOOT PRINT. ADDITION IS ENTIRELY UNDER COVERED FRONT PATIO. Pleaae Note: BUILDING DEPARTMENT USE ONLY linesandconsWctingimprovementsacco 4~-~"-. ~ -00~ S40roved plan afdlr~qf~iied development Approval n~MP FRONT YARD SETBACK OKAY The City is not responsible for inaccuratc submitted within the plan set and any co Zoning : R-1 errors resulting from inaccurate infon WITH MINOR NOTE ON VENT LOCATION 5/21I02. SHOW ACCESS Approval : BG TO CRAWL AREA P-0JOIN n,a$M",* Approval DO Occupancy : Walls : Roof : Stories : Resitlential Units : Electrical License No : Company : Expiration Date : Approval: Plumbing License No : Company : Expiration Date : Approval: Mechanical License No : Company : Expiration Date : Approval: (1) This permit was issued in accortlance with the provisions set torih in yopur application and is subject to the laws of the State of Coloratlo antl [o the Zoning Regulations and Building Code of Wheat Rid9e, Colora0o or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorizetl is not commencetl within sixFj (60) days hom issue date or (B) the builtling authonzed is suspended or abantlonetl for a period of 120 days. (3) If this permit expires, a new permit may be acquiretl for a fee of one-hatl the amount normally requireQ provided no changes have been or will be made in lhe original plans and specifcations and any suspension or abantlonment has not exceeded one (p yeac If changes are made or if suspension or abantlonment exceetls one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be tlone that will change the natural Flow of water causing a tlrainage problem. (5) Contrector shall nofify the Building Inspector hventy-(our (24) hours in atlvance for all inspections and shall receive writlen approval on inspection wrd 6efore proceetliing with successive phases of ihe job. (6) The issce of a permit or the approval of drewings and specifcations shall not be construed to be a permit for, nor an approval ot, any violation of the provistbns Fthe buil'7g cotles or any o[her ordinance, law, mle or reguiation. f i l Chief Building,Y pector DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Numbec oF W"E'T q BUI'LDING INSPECTION LINE - 303-234-5933 Date: CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (3,y0H3-2H35-2855)5~F 7~~ ~OC ORAO~ 4i-Ci~UCFil-l i ~~Y Property Owner: -be 0-4 rt ~n Properry Address: tpp22 V..) Phone :~jp3- Z~'~' v 13 Contractor License No.: Company: Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by [his pemit application are accurate, and do notviolate applicable ordinances, mles or regulations ofthe City of Wheat Ridge or covenants, easemenis orteshictions of record; tha[ all measmements showq and allega[ions made are accura[e; that I have read and agree to abide by all conditions prin[ed on this application and that I azsnme fiJl responsibiliry for compliance with tlie Whczt Rldoe Building Code (U.B.C) and all o[her appficable Whea[ Ridge Ordinances, for work under this permit ^ . (OWNER)(CONTRAC70R):SIG S R-- DATE 18LOZ Construction Value:$ 3kMb. Permit Fee:$ Plan Review Fee:$ Use lax:$ Total: $ Description: Qh-f~0. ~ C~r2V~ tSLI 1r~ause, bu.~'-- c v~.~ I~nes ~n,o~r' -e~pa~u~-~ la~use `~#Qr-cwt ~tu~ c eu~'f-C e,~ v ~-&e u c~ve,v-e ~4 t {t o BUILDING DEPARTMENT USE ONLY SIC: ZONINGCOMMENTS: Approval: c Zoning: R- 2 ~ ~o /I / L BUILDING COMMENTS: (of9a'Di 'r7 N~~AO/ 1+sJe P/1 ~7 ApProvaL 6 .6. C S {ww v9t6e3 PUBLIC WORKS COMMENTS: Approval: ~ U~ Occupancy: Walls: Roof: Stories: Residentia Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Expiration Date: Approval: APProval: APProval: (1) This pemit was iswed in accordauce with tlie provisions sec forth in yonr applicaROn and is subject to the laws of the Statt of ColoraAo and ro the Zoning Regulafions and Building Codes of Wheat Ridge, Coloredo or any other applicable ardinances of Ne City. (2) This pmvit shall expire if (A) Ne work anthorized is no[ commenced wiHiin sixty (60) days fiom issue da[e or (H) tlm building authonzed is suspended or abandoned for a period of 120 days. (3) If [his permit expires, a new pemit may be acquired for a fee of one-hatf the arnoun[ notmally required, provided no changes have been or will 6e maAe in tlie original plans and specifications and any suspension or abandonmrnt has not exceedeA one (i l year. Ifchanees have been or if suspensirn" nr ahnndonmem exceeds one (1) yeaz, fiill fees shall be paid for a new pamit. (4) No work of any manner sliall be done that will change the nanaal flow of water cansing a drzinage pro6lem. (5) ConnacrorshallnotifytheHnildivglnspecrorRVenty-four(24)honrsinadvance forallinspectionsandshatlreceivewrittenapprovalaninspecnoncardbefore proceeding with successive phases of the job. (fi) '[7ie issuaace of a pemit or the approval of drawings and specificarions shali not be consmmd ro be a pemit for, nor an approval of, any violztion of the provisions of the bwlding codes or any ather ordinancy law, rule or mgula2ov. Chief BuIl~~ar Co ~D2€S yq,Z za 24 Zo. I Y V~ ! n.~ i ~1( ' ~f r ~ r -.1.. ~~tC~F. r ~iz~ ctLz; J ~ _ W ~ A,PPR0 vEDiens S r ~,ct 40 ~ ; patc.5~~-~°x ~ plan Chacknr - FH h?sF Joe and Cari Schieffelin 10022 W 315t Avenue Wheatridge, CO 80215 Kitchen Bump-out/Eating Area Expansion - This permit application is for a small 4' x 9' addition to our kitchen - The addition is on the front (north) side of our house and involves expanding the eating azea in our kitchen by "bumping-ouY" the front kitchen window. - This addition is entirely contained beneath our existing covered front patio, so no roof modification or "footprint" modification is necessary. - The footing and stem-wall drawings show a 4"x16" footer with a block wall. Since this drawing was made, we have spoken with a contractor who will pour a solid cement stem- wall 8" thick to the same dimensions shown for the block wall. - All other construction will match the existing construction materials and styles of the house: - 2x8 floor joists @ 16" oc - 2x6 ceiling joists @16" oc - doubled 2x6 headers with a%z"plywood center above windows - engineered header above widened opening in existing wall: see Boise-Cascade specifications - all other framing = 2x4 @ 16" oc - brick veneer as wainscoating below windows; lap siding above brick veneer - new vinyl windows installed - no changes in plumbing aze involved in addition - Drawings included: 1. Plan view of entire house showing location of kitchen bump-out addition 2. Drawin A: Plan view showing general dimensions 3. Drawin : levation view looking east 4. Drawui levation view looking south 5. Drawui,K W. Elevation view looking north of modified existing front wall of house 6. Drawing E: Plan view of heating and electrical BOISE CASCADE - BC CALCT"" 2001a DESIGN REPORT - US Tuesday, May 07, 2002 14:54 ouble - 1 3/4" X 7 1l4" V-L DF 2800 Nlame: Untitled Job Name - JOE SCHIEFFELIN Customer - HOME DEPOT 1526 Address - Specifier - Designer - Colleen Blake Ciry, State, Zip - Company: - Boise Building Solutions Distribution Code Reports - ICBO 5663, NER 442 Misc: - WINDOW HEADER Q o tz ~ Standard Load - 30 PSF ~ 15 PSF TnDUtary 10-06-00 - 'i BO Bi 417 Ibs LL 1477 Ibs LL 3p Ibs DL 738 Ibs ~J General Data Load Summary Version: US Imperial ID Description IS Standard Member Type: - Roof Beam Number of Spans - 1 Left Cantilever - No Right Cantilever - No Slope 0/12 Tributary 10-06-00 Repetitive n/a Construction Type n/a Live Load 30 PSF Dead Load 15 PSF Part Load 0 PSF Duration 115 Disclosure The completeness and accuracy of the input must be verified by anyone who would rely on the output as evidence of suitability for a particular application. The output above is 6ased upon building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with the current Installation Guide and the applicable 6uilding wdes. To obtain an Installation Guide or H you have any questions, please call (800)232-0788 before beginning product installation. U 1`O Controls Summarv ConVol Type Value Horizontal Lenath - 09-00-00 Load Type Ref. Start End Live Dead Tri6. Dur. Unf.Area Load Left 00-00-00 09-00-00 30 PSF 15 PSF 10-06-00 115 Moment 4850 ft-Ibs End Shear 1866 Ibs Total Deflection U339 (0.318") Live Deflection L/516 (0209„) Max. Defl. 0.318" (Limit: 1 Span/DeDth 14.9 %Allowable Duration 55.7% @ 115% 33.7% @ 115% 53.0% 46.5% 31.8% meets Code minimum (U180) Total load detlection criteria. meets Code minimum (U240) Live load deflection criteria. meets arbitrary (1") Maximum load deflection criteria. n bearing length for BO is 1-1/2". n bearing length for Bt is 1-1/2". r Slope = 0, consider drainage. Loadcase Span Location 2 1 - Intemal 2 1 - Left 2 1 2 1 2 1 1 A-P?,OK a Zp ~ Ur ~ 12 GL., VG a-;FND QocZL~} (f , US't a He2- 8 r (O v L ~ 1. ~S C>K{~ANDliVG OPCNtN(!; To i ~DK = Zo - - - - --I I I 1 1'2o r~os OPEr'~N~ f , 1y9B 2x_rafters spacedO.C. or Manufactured Trusses spaced_" O.C. /examp/e.'2x10RaRersSpaced24'D.C.J Minimum lx ridge board - . (examplerlxf2) 12 . Note: Attic ventilation and access may be required - Provide solid 2x blocking between rafters or trusses ~ Note: Pre-engineered rooftrusses w/truss clips and hardened nails may be used in lieu of roof structure shown. Diagonal wind bracing or plywood shear panels @ corners and each 25' of walL Note: Pre-engineered floor systems may be used and should be installed according to the manufacturers installation instructions. 18"minimumfromtheinteriorgrade 'S level to the bottom of the floorjoists. pla~ T Engineered Design: Cassions may be required ; if your site has swelling soils. A foundation designed A ~ by a Colorado licensed archflect or engineer may be required. . Roof covering Ceilmg Insularion (example: R,30J - Wall Insulation R-15 (examp/e: H-13 Fiberglass Ba#s/ 2x (vi ceiling joists @ I k O.C. (examp/e: 2x B B 24'0.C.) Double 2x-4Ltop plate fexamp/e:2x4) . Foundation: E . ngineered Design ❑ Foundatlon: Detail A (see page 3) PropertyAddress: Do2~ 3~" Permit#:E-~ This handout was developed by the Colorado Chapter of the Intemational Conference of Building OHicials as a basic plan submittal under the 1997 Uniform Codes. It is not intended to cover all circumstances. Check with your Building Depadment for additionel requirements. NOTE: Roof not to exceed 24 foot span Sheathing - - (examp/e: ~/z'ex/enorplywood) . i Span~ (example:23'5) Ceiling height-IL- (examp/e: e'J I r-ior) Wall sheathing Yib QSB L /exam0~'/z' eHeriwP~N~) 2x -ASiudS @16 O.C. Corit. 2xI Joists @ A- O.C. (exemp/e: 2x10 024'O.C) -Wall"width. „ i Footing size -L "x (examp/e: 8'X 16') 121 91- A~l k, 1 k t ~y I fl A ~ N p + ' l4 E 9 5 A V ~ E S F ~ 1 9 ~ ~ f _r I G P rye ~a t PM E y tl 1 y V F \!i 0 r---f 0 SI5 ja r \e L, €1QG~z "tt ~t y y v. { i~ ~y sa, Y r i i s ~s a 1 ` ff n 9 31 NT3 Ile 'I 1 F n ~ - f E J I P ~ F 5 1 ~ h S g ~ ~ G v 01 #a ~ u rl r-ZS c r~ U L 1 U„66xstk). xtf l%ftA QJI bs%V HTGtl F,~j VV ~~M k ti It r ell s kt ~1ta i v`` k S GEI~RAL NOTES 1. LHIE LOADS A. FLOOR 40 RSF. PARKHURST B. BASS WIND SPEED 65MPH. fXPOSURE C. C. ~1SMIC ZOF~ 1 INCORPORATED B'-iD" 2. STEEL Structural Consulting Engineers A. USE A307 BOLTS 2140 S. IVANHOE ST. #208 3. CONCRETE DENVER, COLORADO 80222 PH: (303)584-9481FAX: (303)584-9482 A A ALL CONCRETE SHAH. DE~LOP BOO PSI COMPRES~VE STRENGTH #N 28 DAYS, S ~ B. MIX SHALL CONTAIN A MINMUM Of 5.5 SACKS OF PORTLAND CEMENT PER CUBIC g YARD. S } C, MAXIMUM SIZE OF AG(iTtEGAIE IS TO 8E 3/4". d. REIt~ORCING - - - - - A. All REINFORCNG STEEL SHAH ~ NEW BILLET BARS NI ACC(%tDANCE WITH ASTM r--- 1 o I ~ A615. ' P.T. 2X8 9 16" B. ALL ITEiNFORCING STEEL SHAM HAVE A MINIMUM YIELD POINT OF 60,000 ~ I I PSI UNLESS NOTED OTHERWISE. ~ ~ ~ ~ ~~6 G, ~ NOT WELD OR ENO ANY BARS Wffti A YIELD POM1f GREATER THAN 40,(%10 PSI D. REINFORCING PROTECTION i i. CONCRETE POURED AGAINST EARTH 3.0 IN. 2. CONCRETE IN FORMS BUi EXPOSED TO EARTH OR WEATHER 1.5 IN. D f. All. CONCRETE WORK SMALL HAVE N(} JOINTS 1N A HIXiQONTAI PLANE B S ~ EXISDNG FOUNDATION EXISTING FOUNDATION 5. EPOXY W A Dfilll HOLES 1/B" LARGER THAN ANCHOR aAi~TER. DfNll TO DEPTH SHOWN ON DRAWINGS, B. WfTH PRESSUPoZEO NR BLOW OUST OUT Of QRILLED HOLE, O C. WffTl PRESSUf~ZEO WATER WASH OUT DfNIIED HOLES. w~ a D. WffH PRES~IRIZEO NR ~.OW Df~` DRN.IED HOLES. NORTH NORTH E. INJECT EPOXY THROUGH EXIENSKIN 1UBE INTO HOLE. F. INSERT ANCHOR TO REQUIRED DEPTH. EPOXY SHOULD EMERGE FROM HOLE AROUND THE Q ANCHOR. THIS WILL BE INSPECTED fOR PROOF OF FUII EPOXY QEPTH. G. BRACE ANCHOR SUCH THAT NO MOVEMENT Wlll OCCUR FOR AT LEAST 24 HOURS. O w I- w ~ 4"=~'_O" ' " H. ND ANCHORS ARE TO BE USED UNTIL THE EPOXY HAS CURED ACCORDING 10 ) (1/4 -1 -0 ) cry O MANUFACTURERS REQi11REMENTS. P,T, IND~ATES PRESSURE TREATED J. CURING CONDfQONS AS TO TEMPERATURE AND MOISTURE SHAlI MEET OR EXCEED MANUFACTURERS RECOMMENDAibNS. W 6, WOOD A. UNLESS NOTED OTHERWISE, USE N0. 2 OR BETTER GRADE O(NIGTAS FN3-!ARCH Z C~ O ANO N0. 2 OR BETTER GRADE HEM FIR FOR WAIL STUDS. L~ w O 8. PlYWOpD OR ORIENTED STRAND BOARD (O.S.B.) i. FLOORS U7 o. U~ 3/4° APA RAT€D TONGUE AND GROOVED STURD-i-FLOOR aUEfl AND w SCREWED WITH NO.6 X 2 1/2" SCREWS AT 8" ALL MEMBERS. FACE OF EXIST:. 2. waL[s _ . N CONCRETE a. USE 7/i6" O.S.B. N b. MAN. WITH 8d NAILS AT 6" ALL SUPPORTED PANEL 0 EDGES, AND AT 12" ALL FIELD NNLS. C. NAILING SCHEDULE NEW CMU GRADE i. SEE UNIFORM BUILONdG CODE 1997, TABLE 23-II-B-1 & 23-1-8-2. 2x6 PRESSURE TREATED PL WRH BEAM 1/2' DN. X 10" (+2" TK)OK) 1. FOUNDATK}NS O ANCHOR BOLTS 4'-0' MAX. A. FOOTINGS i. BEARING PRES~1f~ USED IN DESIGN 1,D00 PSF. 1. ALL FOOTINGS SHALL BEAR ON UNDISTURBED SOIL OR MECHANICALLY COMPACTED BOND BM. W/ 2-~5 STRUCTURAL FN~L. D 3. LOCATE FOOTINGS ON CENiERIMdES OF WALLS, GRADE BEANS, OR COIUMN$ ABOVE UNLESS NOTED OTHERWISE. D III=11I=III IILII~ - IIHII=III Q -1 I ~I I I. _ s. o A. ALL COMPLETED REMFORCED MASONRY WAILS SMALL HAVE A MNXMUM F'M OF 9 GA DUR-O-WAL ®16" ~4 D(?WELS X , " ®24" 1500 PSI' 1 _p 8. MASONRY UNITS SHAH CONFORM TO AS1M C90 LIGHTWEIGHT GRADE N TYPE I. Z C. VERTICAL REINFORCNJG SHALL CONFORM TO ASTM A615 GRADE 60. ALL R ,:g o g' ~ SPLICES SHALL HAVE A LAP OF 36 BAR DIAMETERS. i 2-~5 CONT. D. US€ TYPE S MORTAR. MID-DEPTH 2_#~ X~'_6" E. All REINF(?RCED CELLS AND BOND BEAMS SHALL BE GROUTED SOLID WITH EPOXY INTO 6" "COARSE" TYPE AS DEFINED BY ASTM C476. fi, DEEP DRILL HOLES F. SEE p2AWINGS FOR ADOffK3NAL REINFORCING. G. HORIZONTAL REINFORCING SHALL ~ OURS-WAL LADUR TYPE 9 GA. AT 16° ON 14 ~ , , CENTER. USE PREFABRICATED TEES AND CORNERS AS REQUIRED. s~. qty _ - - i H. PROVIDE 80N0 BEAMS WITH 2-~5 CONQNUOUS Ai TOP Of WAIL. 9. DO Nt}T PLACE BACKFILL AGAINST CMU WALLS UNTN~ THE FLOOR SYSTEMS ~ ARE IN PLACE. PROVIDE All NECESSARY BRACIt~ TO SUPPORT ALL WALLS AND TO PREVENT TF~IR BUCKLING DURING Bi~KFILLING AFq COMPACTING 1'-d" OPERATIONS. REVISIONS iD. CONTRACTOR SHAH VERIFY WITH THE ENGIt~ER ANY DISCREPANCIES FROM ASSUMED EXISTING COt+gffK)NS. NO. DATE A E3 ii. REFERENCED CODES • S 1 A UNIFORM BINIDiNG CODE 1997 B. ACT-318=98 C. AISC - 9TH EDTDOFI JOB NO. 794 DATE: 4-25-02 SHEET NO. S