Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7425 W 29th Avenue
City of Wheat Ridge Residential Roofing PERMIT - 201701656 PERMIT NO: 201701656 ISSUED: 06/06/2017 JOB ADDRESS: 7425 W 29th AVE EXPIRES: 06/06/2018 JOB DESCRIPTION: Reroof 31 squares OC Oakridge shingles, single story , 6/12 pitch, house and detached garage; 24.33 squares for house and 6.66 squares for detached garage; 31 squares total *** CONTACTS *** OWNER (303)877-9068 WRIGHT SCOTT SUB (630)353-1900 Mike Gray 130198 American Dream Home Improv. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 13,175.00 FEES Total Valuation 0.00 Use Tax 276.68 Permit Fee 267.70 ** TOTAL ** 544.38 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A�/a-inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€ms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. - . City of Wheat Ridge Residential Roofing PERMIT - 201701656 PERMIT NO: 201701656 ISSUED: 06/06/2017 JOB ADDRESS: 7425 W 29th AVE EXPIRES: 06/06/2018 JOB DESCRIPTION: Reroof 31 squares OC Oakridge shingles, single story , 6/12 pitch, house and detached garage; 24.33 squares for house and 6.66 squares for detached garage; 31 squares total I, by in signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal �neI0fthe proerty and am authorized to obtaithisernlitand perform the work descibed and approvedinconjuncton with thisettheratt th am 1 allyauthorized toinclude a]I entitiesnamed within thisdocument as parties to thework tobeperod ahatnallgrk t� e peormed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONT�CTOR (Circle one) Date 1. This permit was issued based on formation provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and_procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed_ or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a pe all not be -coo strued to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinan __of tit cti ' . Approval of work is subject to field inspection. J Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequestgci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. DNCO-261449 Week: 06/12/17 Printed: 06/05/17 Cit\/ of �Wh6atPjd COMNAUNrry DEVELO MENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits .ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit #Qo) 1 W 6 S Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 7425 W. 29th Ave. Wheat Ridge, CO 80033 Property Owner (please print): Scott Wright Phone: (303) 877-9068 Property Owner Email: Mailing Address: (if different than property address) Address: City, State, Zi Architect/Engineer: Architect/Engineer E-mail: Contractor: American Dream Home Improvement, Inc. Contractors City License #: 130198 Contractor E-mail Address: cncoprod.adhi@gmail.com Sub Contractors: Phone: Phone: (720) 398-6672 Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL [N RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Re -roof 31 Sq. w/ Owens Corning Oakridge shingles, single story, single family, single layer removal, 6:12 pitch, house and detached garage structures only. 24.33 Sq. for house and 6.66 Sq. for detached garage. Sq. Ft./LF Amps Btu's Gallons Squares 31 Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) 75.00 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNS (CONTRACTOR r (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Electronic Sitnature (first and last name): R n -Ua caiktxt DATE: 06/05/2017 ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ W -A "r�'� ,� CAU t✓eAT 7OLU 77& PLATINUM _ (ONTRACTOR R00RNG-S10ING - GUTTE=RS' ' 6746 South Revere Pa'ikwaa Suite B450 Centennial, CO 80112 'Phone 720-39.8'.602 ;Fes 303=951.-8447 Name: W O -4 K �.rtknrfr Address: Billing Address: i ` R\dC18,tai SestPhone-.2-65 y� �u insurance Co: `C ROOFING SPECIFICATIONS ' fr Shingle i�- r ' le ..Qhl�.YtD f4 yikolor of Shingle: + earaff: �, LaVA.. rs:_ © 2 -Story iPitch: t VIce & Water Shield ents Q � 0's . M Ridge 0 Turbines rip Edge qAPJumbTng Jacks .0 Skylights ILL Turn Ended Yilarranty *omove debris from roof, gutters and yard Il yard with magnetic railer I'll-Weet iarirlscaping , �F` +rnish Permit . SIDING I GUTTER SPECIFICATIONS Q Mfr. Siding Calor: `j 0 Style of Siding: Q D4 0 Dutchlap d 0 Fanfold Insulation L7 Hcusewrap \ Saffit O.Fascia.... utters Downspouts_O OS Downspouts - 0 Window Wraps a flQos,n►iaps 0 Trim Colors: �J? Ta Remove debris from yard O Protect landscapirig h� 0 Furnish Permit r V SPECIAL INSTRUCTIONS Li tl-r d 'Ci- L•A r r r:...�1 INE DO NOT ACCiEPT.CASH Date:' City/State: "7J Citylstate- ZIP: Errnail: . Claire Number':;, DAMAGE REFO�01 0*0f . Q Wind O+fWI 0 Type: 3 T&*6 0 Siding 0 Wind -0. Hail" � 0 Type: _ f3.Wind t4iail 0Type: A/V^ , 0 Soft'ri/Fascia Q -Wind M Half . 13 Typ-e Qth�r Q Wind ❑ Hait .. Q Type:` 'DAMAGE NOTES.___ :.. _ (.PY'✓ ,: � -sem �•�r��•��� �� �00 >_ ACREg800fing SC . ik.. .Total$ 0 Siding SO, S/5o. Total$ AG-,,U#r-S LF. $&F- _ Total$ LF. $&F. {� Total$ 0 offit 5F. MR Total$ II• Fascia t F: S/L F. Totals n Wraps QTY. 5/Ea.. Totals O S/� Total$ D — $ OEDUC1`18L1: S c-64 PAYMENT SCHE15ULE First Payment Due upon Delivery of Material Paid Date:..- c. / .. '! '.,.:.. CK# ... - @ S Paid Dote-: / ! CK# . @ S Balance Due On Completion DISCOUNTS Olt CREprrS WILL 9E NONORP UPON FKkL PAYMENT. PRICE AGREEMENt NOTE: Pricing is separated by tr de and subject to insurance co. apprmi on an ki dividitat basis. The deductible is the homeowner's responsrita ty, Homeowner lis not obligated to any trades that are not approved by the insurance co. lNStlI2ANCl=lMOItTGAGE NOTE: ! Hereby authorize any insurance company, mol�ne company of iender involved with the property address tested above to issue all payments jointly and release all documentation to American Dream Home improvement. Inc, to assist in expediting itse claim process. TERMS: This agreement does not obligate the homeowner orADHI, Inc. in any way unless it is approved by.the insurance company and accepted by ADHI. Inc. By signing the agreement the homeowner. authorizes ADHI, Inc, to pursue the homeowner's best interests for a roof /.siding repla 'MIP.G .at a "price agrt�abie- to the insuranoe'co. and ADHI, Inc. with no additional out of pocket'cost to the homeawnerezce.pt for th uctlbf . Upon approval or confirmed= by my insurance company .on the scope of damages andior agreed price a$ Iisied' onAhis agreeme uthorizeADHI. Ina to obtain faborand material in a=rdance with this "pFce agreemeist' and the specifications set out herein and on the reverse sloe hiriof to accomplish the replagerngnt or repair. ADM, Inc. all, hold In trust any payment from the properly owner until the roofing eorttr has delivered roofing materials at the presidential 010V s T has pei ' ' id; ' majority of the rooting work on the resideyi Representative Primed Name ofAIWI, Inc. Repr sentative A i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: -/ 2 LAV/�-- Permit Number: O / % /{� ❑ No one available for inspection: Time/ -' AM/PM Re -Inspection required: Yes t' N) When corrections have been made, call for re -inspection at 303-234-5933 f f f. Date. �,�_ Inspector:—,-.'. DO NOT REMOVE,THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: �/ LAS 2 C! Permit Number: `2_0070/6_5W ❑ No one available for inspect' n: Time ,� AM/PM �' � Re -Inspection required• Yes When corrections have been de, call for re-inspecti a 03-234-5933 Date: / '/ Inspector: DO NOT REMOVE THIS NOTICE Permit#:20120099 Issued: 09/21/2012 Stipulations: Interior and Exterior Remodell This certificate verifies that the building constructed and/or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code and development standards of the zone district in which it is located and may be occupied. All other licensing requirements for the City must be met. Contractor: Adrian Delgado 13498 W PURDUE DR MORRISON CO 80465-1124 A i CITY OF WHEAT RIDGE �� Building Inspection Division ►/ (303) 234-5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE -HYiC ❑ No one available for inspection: Time AM /PM Re- Inspection required: Yes No When corrections have been made, call for re- inspection at 303 - 234 -5933 Date: CIl `_)� �''�' Inspector: DO NOT REM OVE THIS NOTICE Inspection Type it F0 Job Address Permit Number Ah DO gg Address: 74o2f iii � -Aill teta C V City, State, Zip. SEEM Electrical: Plumbing: Mechanical: Squares BTUs Gallons_Amps_SqFt._ KeVIeWer, PUBLIC WORKS COMMENTS. OCCUPANi— Reviewer. FIRE DEPARTIiiil 0 approved w/cowmen s Odisapproved O no review required I SidgVatuation: M J IMN A P PiR O'J ED Subject to Wheat Rid . P; 6TvL l l '" � EM ,, .ity Of 00 wI l '?, « : 7500 W. 29 Ave�� Wheat Ridge, CO 80033 Km Plea # l' °it�� Ac ;. Daniel J. Hontat, Architect LLC 4042 S Quebec Street Denver, CO 80237 a= P.O Box 2352, Evergreen, CO 80437-2352 Phone: 303.670A811 Fax: 303.670.9472 Residential Worksheet t 7 Ad dies : Zoning: Property in the fl(, Plain? Lot Size: stl. ft, Lot Width: , _ 0/ Maximum Lot Coverage: 3 C.) /0 / ; s cl , ,Proposed Improvements: Existing llrrrproverrient(s): 11011se. --- - sq. House: 0_ sq --------- Addition to House: sq, ft. Shed: sq, Shed: __-._- sq. ff Detached Garage: sq, Detached Garage: sq, ft, Other: ____ _______1_ sq. ft / 0 ( �'� - Proposed Lot Coverage: (Total) % sq, t, R Requited Setbacks F S V S Provided Setbacks: FR S _ ___ S P. Maxim uni Height ft Proposed Hei�bt: Maximum Size: sq. ft. ProPosed Size: scl, AJCC —eISS.N For one and two-fainily dwellings, the first 25' of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or surtilar materials. For all uses other than one arid two family dwellings, no vehicle entrances or exits may be closer than 25' to ally p lijic, except when used as joint access for two or more lots. In residential zone districts, curt) cuts shall be at least 10 feet and not more than 24 feet in width. One and two-family dwellings may have horseshoe, driveways, provided that the street accesses are at least 30 feet apart, measured from the interior edges. For all uses, one access p per property is permitted, 1,andscaLing Notes For one-and two-family dwellings, one tree for every 70 feet of street frontage is required. 100% of the front yard and 25% of the entire lot must be landscaped prior to issuance ofCO, Street trees required: Street nees provided� STATE OF CO LO RADO COUNTY of 7 �.w m TP my MY otaty the L AFB sat) A It 10 A 1233ELMBME Energy Code: 2009 IECC Location: Wheat Ridge, Colorado Construction Type: Sit7le Family Project Type: A d Ition/Afteration Heating Degree Days: 6168 Ornate Zone: 5 Construction Site: Owner/Agent Designer/ Contractor 7425 w 40th ave 7425 w 2M Lt" C keesh pankey wheat ridge, CO 80211 3424 w 40th eve donvor, CO 80211 7209765708 dylonconcretsworks@gmaiLan Project Title; 2M Report date: 01127112 Data filenarne: Unfitted.rck Page 1 of 4 Project ritle: 29th Report date: 01/27/12 Data filename: Unfitted.rck Page 2 of 4 fenestration d maximum } of 0.50 and the maximum } Y Duct Construction and Testing: L) Building firaming cavities are not used as supply ducts. ( POstOOnStructiOn leakage tO outdOM test Less than or equal to 8 cfm per 100 ft2 of conditioned floor area. (2) Postconstruction total leakage test (including air handier enclosure): Less than or equal to 12 cfm per 100 V, `.• ! h total leakage ' ... • t d: Less then or equal Y ♦ chn per IGO Q of • • i.. } .}•.. area, Temperature Controls: Ll Where W primary heating system is a forced air-fumace, at least one programmable thermostat is Installed to control the primary heating system and has satj)oints Initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle. Lj Heat pumps having supplementary electric resistance heat have controls that prevord supplemental twat operation when the compressor can } foad. Heating and Cooling Equipment Circulating Ll Additional requirements for equipment song am Included by an inspection for compliance with the international Residential Code. Lj For systems serving multiple dwelling units docimientation has been submitted demonstrating compliance with 2M9 IECC Building Mechanical and/or Service Water Heating (Sections 503and $04). Service Hot Water System; Ll • service } water pipes are insulated to 'w. Circulating Ll Service } water systems include an automatic or • M manual switch to turn } circutiatmil Y pump when the system Is not in use. Heating and Cooling Piping insulation: Swimming HVAC piping conveying fluid$ above 105 degrees F or chilled fluids below 55 degrees F are insulated to Ra Pools: Ll Heated swimming pools have an ontoff heater switch. Ll Pool heaters operating on natural gas or LPG have an electronic pilot fight. Li Timer switches on pool heaters and pumps are present. Excep Where public health la require • } pump operation. Where pumps operate within solar- and/or waste-heat-recovery system. Heated # pools have w cover on or at water alt: For pools heated over 90 Ym•. *. degrees cover .. a: the insulation minimum of Project h Report date.. 0//27112 Data filename: Untittedia Pap 3 of 4 1 1 i 1 1 1 1 1 ; 11 Ughting Requirements- Other Requirements: Snow- and ice-nialling system with energy supplied from the service to a building shall include automatic cormols capatite of shutting off the system wtm a) the pavement temperature is above 50 degrees F, b) no precipitation is failing, and c) the outdoor temperature is above 40 degrees F (a manual shutoff control is also penrittled to sell* requiremente), Lj A permanent certificate Is provided on or in the electrical distribution panel listing the predominant insulation R-values, window 1.1-factors; type and efficiency of space-conditioning and water heating equipment. The cerfificate does not cover or obstruct the visibility of Me circuit directory label, service disconnect label or other required tabels. Sunroo that ftht are lharnially isolate sk U_ lacror o d f O 75. New from "Ie building enVk,— reqUiranio— wirwf—.— - Ceiling I Roof 0140 Wail 0.00 Floor I Foundation 0.00 Ductwork (unconditioned spaces): r. Heating System: Cooling Water Heater Name: Comments: Contractor shall comply with all state and local licensing and registration requirements for type of activity involved in the specified work. (Check one box and provide description) [I Contractor's state license or registration is for the following type of work and carries the following number: I ip� III I� I I I � I I I IIIII III lI I I 6. Liability Waiver If contractor is injured in the course of performing the specific work, Homeowner shall be exempt from liability for those injuries to the fullest extent allowed by law. 7. Permits and Approvals (Check the appropriate boxes) Additional Agreements and Amendments SEMUMMI= Homeowner. Dated: Contractor: Dated: 1 04 'Iff 10, Ali OR 116 NIP. R YOU MAY HATE AMJU'1 CONTRACL 7425 w 29 h 11- Homeowner, desires to contract with, _ GL Constructionjnc 017111 certain Work Contractor, to perf on property located at: L. Job Description 2. Payment Terms Y appropriate boxes): 3. Time of Performance The work specified in this contract shall (check the boxes and provide dates): begin on be completed on D Time is of the essence 4. Independent Contract Status 5. License Status Number WWISSWA�� a =# Tile are 332 sq feet total Bathroom ©' removal $156.0■ Removal & replacement of existing toilet $50.00 Underlay tile area including shower walls $1.00 x 332 sq feet $332.00 Backer board price $9.00/sheet x 23 sheets $221.49 Install tile 332 sq feet x $4.00/sq foot $1328.00 Remove & replace baseb„ : ¥ y 3.00 (Price includes material) Stair nose $8.00/piece x 1 piece $8.■0 Removal & replacement of subfloor in back room $500.00 Carpet removal $0.50/sq foot x 216 sq feet $108.00 071M M7VrFMX — - 'r< I al z FT-1"9A The remaining 50% is due on day of completion. Proper Plumbing LLC Proper Plumbing LLC 3740 LOWFLL BLVD DENVER, CO 80211 I I MOMIUMI H It ------------- ....... Amount Due Enclosed .... ..... ... .. .... $1,000.001 City of Wheat Ridge Municipal Building 7500 W. 29 Ave. Wheat Ridge, CO 80033-8001 P: 303.2352855 F: 301237M29 1/25/12 Adrian Delgado Colorado Quality Construction 13498 W. Purdue Drive Morrison, Co. 80465 Re: 7425 W. 29' Avenue Wheat Ridge, Co. 80033 Dan= I arn in the process of reviewing remodeling and plan for a new garage and require the following information to continue my review. Once I receive this information I can continue with my plan review. If you have any questions feel free to contact me. wwwA.wheatridge.co.us w I Ill m 101 "M. t �'��1 1 2 1 cry � v 1 C . R it ga �j,4 to 1 % Me ",. r i f N1 M • • • + • r • w • • � i s • . z +6z z z z 0 y l 1 H sw tzo ton bb by P w* r r. ton � � i f N1 M • • • + • r • w • • � i W z +6z z z z z y l 1 tzo ;o Y� g q 1 X" �I r +�µ M1wY uW i f N1 M • • • + • r • w • • MI! k M � b YI NF IM^ 0 � sw +� sr sr w * f i III � w 1 0 • � i W t y l 1 �I n ew w # sb`rm s. w s a 4 � a A e * w a # An b e' k MI! k M � b YI NF IM^ 0 � sw +� sr sr w * f i III � w 1 0 • m � i W t y l 1 m M. N i►` mi N1 w 0 z 2 .* � G) 0 c 65 n t!3 m to Ch Ln 8 b z 0 Y z z z X z 6 CE 0 mi N1 w 0 z 2 .* � G) li to 0 z z z 6 CE 0 > mi N1 w \� d� } � < d� \� d� \ � § / � \ \ d�� d� � 2 0 a 3 x G » 3 \# <m . ®" � 0 m m C / © « M ± ¥ \ / MC \ o d � «m � \ \ 8 \ * w ^ G � ^ » # 2 ¥ \ m � R F A » [m 0 rs iIIP re 'm u W I r. RXIIII • • Lklej it a 0 m oZ7 • yt+ K 1�P a* dIM f[ ek „w GMs U9e • M MM VA 1p; • 13 aK► kil d k M 9 4 2 GMs U9e • M MM VA 1p; • 13 aK► kil d k M 9 KIM F� Ln ■ CL) rot cu =r > < (D (D =3 0 F� ♦ i CITY OF WHEAT RIDGE Building Inspection Division I (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Job Address: 7W cy •dE Permit Number: G 9?2 ;F(77 t ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes N *When corrections have been made, call for re-inspection at 303-234-5933 Date: SfG~Gt7 inspector: e DO NOT REMOVE THIS NOTICE 1V 1.~ A ft71 ~ T• 1 ~nFwH~QT~a City of Wheat Ridge Building Division °x ; m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 e ~ o ' Inspection Line: 303-234-5933 ORPD_ _ Building Permit Application Date 6, Plan # (P -~1 ~q t Permit Va( b NI Property Address;, /"/;5 ~y u r~ Property Owner (please print): ~n Mailing Address: (if different than property address) Address: 414- &c Phone: j03 - ?-77- 171f7 City, State, Zip: Contractor. Contractor License 7cU '-y~!) Phone: Sub Contractors: AIA- Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Appro v al: Approval: Use of space (description): ~ / c J"tt~(/Gr V Construction Value: $G~~ l Description of work` (as calculated per the Buildinq Valuation a sheet) : sa'°- / V i / F •gp/y~./Cr+,y-->l+Gxy,.F Plan Review (due at time of submittal): $ Sq. Ft./L.Ft added: Squares BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) ~(CONTRACTOR) or PERSONAL REPRP IIIVE off (OWNER) NTRATO 1 PRINT NAME:. on✓iC~ _3r 4utl .~-,LIM SIGNATURES ~ ~wt_ ~ Dater / d Chisholm Consulting Services tM Structural Engineers 1074 S. ALKIRE ST., LAKEWOOD, CO 802 28-31 1 2 PH. (303) 914-8202 FAX(303)914-8203 April 15, 2009 Bret Mueller, Design Engineer REC Solar 9032 Marshall Court Westminster. CO 80031 RE: PV Rooftop Panels Puckett Residence 7423 West 291h Avenue Wheat Ridge, CO 80033 To Whom It May Concern, r, bgr &I Work shall comply with the following codes: 2003 IRC, 2003 IECC & 2005 NEC. This letter is to certify that Walter G. Keske of this office reviewed the roof framing at the existing structure. Rooftop photovoltaic panels are to be added to the roof. Calculations were made to certify the integrity of the panel connection under maximum wind uplift load and maximum live load shear. Based on panel loads at anchor points, the hip-style rafter roof structure is adequate to support the small additional dead load of the panels. The panel connections to roof structure are made with 5/16" diameter lag bolts embedded 2 1/2" and are adequate to support maximum wind uplift loads and maximum shear live load. Please call if there are questions concerning this letter or if we can be of further service. Sincerely, Walter G. Keske, P. E. \ ~~>~luuunii,urui„ R mGs~ G 15814 oCC= ylj s~oq m ~'i F ss~®M Aa N COLON PnO nfml„ 111 O Wheat Ridge Building APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Date: Plan checker Department talid' of per t: T issuance of a permit or approval of plans, specifications comput do shall not be a permit for, or an approval of, any violation to any of t e provisionsof the (wilding code or of any city ordinances. Permits presuming to give authreity to violate or cancel the provisions of the building codes or other ordinances of the City shall not be valid., CHISHOLM Jos Po(keff P.Sl ~e~tF 7VZ3 Z9t-' ~U~ l~wra rF~ e. CONSULTING SERVICES, LTD. SHEETNO. I OF I Structural Engineers / 1074 S. Alkire St. CALCULATED BY e DATE I!!? ~4 LAKEWOOD, CO 80228 Jo~ ,p9f (303) 914-8202 CAEER@OIIV DATE APR-14-2009(TVE) 16:26 REC SOLAR BUSINESS CENTER (FAH)303 577 9629 P.0021004 PUCKETT (501R-425PUCK) a ' a t,~~ x ~3*f ) r iMrFe~M V. 4: jeg& CL =2 9 up ~ ~ M t a M @ [ rC ti+ I Axn~• ly 'It { I u! t e z nlp °s ~ ~ n' kn d ~ ryrr..t~+5tyy F i i~~j yy13 i L a"5'if~ o do J a o n m 1`x k" . F~1 dg wad ~ t~~""'Mrl~lUl~tl"e!a~a1~~i Ia911~>~k~1 ~a~ ~~w .c rs dal r ~a, 1 ?0lr~allbl Gf r< ,~6 m " a ~ a ~ ~1 r~gr~~ e~p~l~~1u a ~t"& P~f~l! I a`~.. ~ J"1 ~ 1? ~ w c7 r/I N ~ P i~ Ing . 110 V'~w riy -u 2NNmm YNb~1~ qq g o it 0~ o ~ ~ Zq b G :i 4 05 u fi yo Z u i i 3 p +reL+ o z Ed a a 13 ° Lu N Ng =re cd. z z a > Q~ 04 a ~ Fg f 6 {Gd a ° W ~8 APR-14-2009(TUE) 16:27 REC SOLAR BUSINESS CENTER (FAX)303 577 9629 P. 003/004 PUCKETT (501R-425PUCK) 6§ f ~ rx mom, J n Q 4 - L Ho I a w J a 00 N ' T,OT Q s Uf v J ~ TM'l ~ W O ~ $q In S i 'V I I} , Q ~El- i APR-14-2009(TUE) 16;27 REC SOLAR BUSINESS CENTER (FAH)303 577 9629 P. 004/004 PUCKETf (5018-425PUCK) a a # ~ ~ V N~ ~cYi ~ a$ Q~zY J~ 2i o N ~ Z ~ ~ W g CZ~SS~~ , S3~m `a 3o~y~oi H~;c~i~$ ~o 6 ¢i o Qy Vige m Gga c GSA„ ~g . J J, d K ~ee d m W Si/ W ~y3{j@ ~ ~ ~ ~ (i 47 W c p W .~FiF. 4 ~ ~ Y Z ~ m ~ N ~ ~ ~ ~ tot H ~ ~ X ry O T.._... _.._I ~~r~#O P~~~ }T. ,yQ~ ~W¢'OC6 "IJ t1t { ~ F6~ wend ~ C~IN.c .~i li o~ ~aS i" L._....._._~ Lu ~ sl ❑ V~ K~yV J ai._.4W ,Q U€yyy€y ~~ey N co $m 8 U 3 ~4 o S w ~y W y y_ W 3 ~ ~ w~ «£~C ui ii n p jJ 6' p ~i{~{ gg aoN~ r ~ ZfL S~= a alp Yf i L'J p2p p; `JK Or .Y. D~W x .Y.Y ~d~ N ~ UN y' =WG W n4 6 W i7ju ~ z~~ !!yy a _ s ~ LL~„~ ~ ~ ~~a ~i SOP qr~ ~r " o3~~i.8 ~ ~ of 'a CiY~ & p o a °d °zw LG^ ~C. yy i SM2 W2 aW `a 9ey9~ ~gS O~w~ O WN ~ W ~Pyg Pyy j fA" °~"1$Y~~~A'•~~!ry^toy~~w ~j}'a,q$~'xp"~a`a e) M ®d B'FF .......Ags W7[J ~••r+£ ?L".yN!"!~,LLy~O.O ~Z.w Wp~ y11~d o~~i rop ~~--''!!~°~J.~fffff~ x q g~"MpCCxWT~~~"~w,s p~~ 6~~ yj wO 4~._f ;I~ Nn L gWOD~Z p~_. w i h~ G6 ~ dog *ze~'~'°5_ro8~~~s ~B r- oWp°°pW~N~ m~mo° x x - ~iE ffo~ W 22 CyO pfap{'NN VN.O.Nti~+m~mpOyy yrw WdW W° 51114 'MArl W.r N W.r ~>ry>6 Nr4 R{1~,6 y~ w nI.4 Nm•V~✓IA~6SW Prp~l Z ~ T T E E K # N U p W W n o ~ ~ ? . » E ~ n N W N m N p N C M P N W U ry W y~ © M c p d ~ F a B 1 6 y' = w N G 7 N w ~ U w u w WF F U ~ ~ u •ay o v q C L7 X P 9 9 ~ ' ~ W rv W ~ ~ y ~ ry 4 U nr ~ ~ ~ j P ~ U y~ ~ u e . .t ~ N. O O w ~ t ~ CS -r` ~ ~G O ~ 4 o « ~a « ~ 7 a r a Y~^, w C c 4 E 4 F ~ N o C w ~ U G C7 ° $ _ O o tim a . m ~ i~ ~ ~ a ~ ~ { W ~ ~ ~ x d X x , C O O ~ W Vl b N U I N 'E N x REC It sour SOLAR MODULE R" (:y SD UNCOMPROMISING QUALITY The AE-Series is a high-quality series of solar modules designed to meet exceptional standards forsystem and module performance. REC manufactures its own silicon, wafers, cells and modules and does extensive quality control throughout the complete production process. REC can be depended upon to provide a secure, steady supply of modules that are manufactured to the highest standards of quality from beginning to end. The REC AE-Series utilizes 60 high efficiency, multicrystalline 6.14 inch (156mm) square cells. The modules provide outstanding performance in low-light conditions due to their special glass treatment. The easy-access rearjunction box has built-in bypass diodes to minimize the effects of shading. The laminate's Tedlar backing and anodized aluminium frame ensures many years of peak performance. The modules are designed to withstand heavy snow and wind conditions. QUICK INSTALLATION Multi-Contact Solarline MC4 locking connectors allow quick and easy inter-module connection, and system installation. The MC FlexSol double-insulated output wiring provides for safer array wiring, and makes the AE-Series compatible with the use of transformerless inverter technology. This insures that the AE-Series is ready today to work with tomorrow's inverter technologies. ENVIRONMENTALLY FRIENDLY PRODUCTS & PROCESSES The AE-Series generates reliable and environmentally friendly electricity. The cell and module production processes are designed to maximize recycling and reduce environmental impact. REC polysilicon is manufactured in the US (Moses Lake„ WA and Butte, MT). REC wafers, cells and modules are manufactured in Scandinavia. FIRST-CLASS WARRANTY The AE-Series modules come with a guarantee of 90% of rated power output after 10 years and 80% of rated power output after 25 years. The modules have a 63-month limited warranty on materials and workmanship. rn e iiQDEL AE205-USA AE210-USA AE215-USA AE220-USA AE225-USA AE230-USA E_EC) RICAL DATA Peak Power Watts-Pmpp(W) 205 210 215 220 225 230 Power Output Tolerance-Pmpp(°~) - t3 m3 t3 m3 t3 m3 Maximum Power Voltage _VmpP(V) _ _ 28,1_ 8.2 2 Z8.3 287 29.7 ..4 29.4 Maximum Power Current - ImPP (A) 73_„_. ZS 7.6 7.7 7.8 Omen Circuit Voltage NOC (V) 36.1 36.1 36.3 36.6 36.8 37.1 Short Circuit Current Ise (A) 7.9 _ 8.1 _ 8.1 8.2 8.2 8.3 Te~erature COetfiaent of Pmpp 0452 -0.452 -0.452 -0.452 -0452 -0.452 Tem Lature Coefficient of Voc(%/°C) -0.34 -0.34 -0.34 -0.34 -034 -0.34 Temperature Coefficient of Ise (%/°C) 0_074 _ 0.074 0.074 .0074 0074 Cell, Efficiency 14;0 _ 14.7 151 154 15.8 Module Efficiency 124__ 12.7 13.0 113___ 136 Max Serves Fuse,Rating (A) 15 15 _ 15 15 15. Values at Standard Test Conditions STC (Air Mass AM 1.5, Irradiance 1000 W1m2, Cell temperature 25 °C) tiQGT ?~`oan}roai 0pe. Minx Cell Ter:apcraPurer} 47.51 The NOCT Values are reached at an irradiance of 800 W/m', at an ambient temperature of 68°F[200Clandawindspeedoflm/s. Performance measurements at different low irradiance levels: 800 W/ml _ -19.6%, 500 W/m' 49.8%, 200 W/ml 80.6%. C us OPERATION LIMITS Module temperature range -40...+176°F[-40...+80°C] Maximum System Voltage 600 V Mechanical load 5400 Pa, equals 112.5 Ibs/ft2 [551 kg/m2] Wind speed Rated for wind speed of up to 122 mph [197 km/h] with safety factor 3 Fire Rating: ClassC GENERAL Cells Multi-crystalline cells 156mm x 156mm, 60 in series per module Module Front High-transparency solar glass with antireflection surface treatment Encapsulation EVA. Backsheet TPT foil Junction box Multi-Contact Solarline MC4 3 bypass diodes Frame Clear anodized aluminum Connection 2 x 61 inches [1.55 m] solar cables with MC4 connectors CERTIFICATION / STANDARDS Certified according to UL 1703 - 3rd edition CEC/CSI listed Revision E March 2009 Note: Specifications subject to change without notice. RaEC For further information please contact your local distributor or visit our web site: www.recgroup.com/usa • 1_ GRID-TIED IN Light Weight Flexible Lower Cost LCD Display Plug-and-Play Reliable IG FOR PHOTOVOLTAIC SYSTEMS 26 Ibs, the FRONIUS IG inverters are the lightest grid-connected erters making them easy-to-install e wide voltage range of 150-500 V allows you to use different types modules and system configuration possibilities. zgrated DC /AC disconnects reduce installation e and complexity. or-friendly and comes standard with every FRONIUS IG; tracks ,re than 20 critical system performance parameters. )ansion slots in the inverter allow you to easily upgrade the inverter h data communication options. nius has been in business for over 60 years and has more than - Recommended PV wer 1500 - 2500 W 2500 - 3300 W 1800 - 3000 W Max. DC input voltage ! 500 V 500 V 500 V Operating OC voltage range 150 -'450 V 150 - 450 V 150 - 450 V Max. usable DC input current ' Maximum output power ®40° C . 13.6 A 2000 W 18 A S 2700 W 16.9 A F ' 2350 W Nominal AC output voila a 240 V 240 V 208 V Utility AC voltage range 212 - 264 V (240 V +10% / -12% 163 - 227 V, Nominal AC current 7.5 A 10.4 A 10.4 A Maximum AC current 4 8.35 A 1125 A 11.25 A Maxlmum utill back feed current fi 0 A 0 A 0 A Operating frequency range i' 59.3-60.5 Hz (60 Hz nom Total Harmonic Distortion THD I: <5% Power Factor I, Max. efficiency - 1 95.2% 95.2% - 94.4% Power Consumption In stand-by ii - . < 0.15 W night Power Consumption during o eratio'n - 7 W Enclosure NEMA 3R Size Ixwxh II 18.5 x 16.5 x 8.8 Inches 470 x 418 x 223 mm) Weight 26 lbs. 11.8 k Ambient temperature range -5 to 122 °F -20 to 360 °C Cooling controlled forced ventilaton Integrated AC and DC disconnects WaBREMM Ground fault protection I{ standard WON Internal GF01; in accordance with UL 1741 DC reverse olan protection I - Internal diode Islandin protection Internal; In accordance with UL 1741 Over temperature Output power cle-ratIng Surge protection ! . Safety - Internal DC & AC protection, Tested to 6 kV . a UL 1741 EMI FCC Part 15; Class A & B Anti-Islanding protection UL 1741 Ground fault deteotor and intern ter Compliant with NEC Art. 690 re uirements, UL 1741 Maximum AC over current protection Two-pole, 15 A circuit breaker AC wire slzin !I Use maximum AWG 6 194°F 90 °C copper wire DC wire 8'z "g Use maximum AWG 8194°F 90 °C copper wire AC disconnect 32 A DC disconnect - 40A Warranty j3 5 Years; 10 Year extended warranty Distributed E E s pas x~ ~Z 9°c t~ HI s ~e ms ~E 5€ Fronius USA LLC Solar Electronic Division 5266 Hollister Ave., #117 Santa Barbara, California 93111 E-Mall: pv-us@fronius.com www.fronius-usa.com B r - bra zsca ~3~~F• Cam' ..._..,.,~,.,,.a,. k may:. ~ »se~~w ~:nwmsa wsrres ;rro ,vv- .n DRAFTER !DESCRtPRON - BRET MUELLER DAN WHITNEY PHOTOVOLTAIC SYSTEM SITE 'PLAN INVERTER & DC DISCONNECT LOCATION APPROVED Subject to Field Inspections SCALE: 1/16"=1' Wheat Ridge Building Dept. AC DISCONNECT LOCATION Date: WEST 29TH AVENUE REC SOLAR, INC. CUSTOMER APPROVAL CO LIC# 7080 775 Fie. Lane, Sul] 20a San LUls Oblapa, 6493403 USA PROJECT FOREMAN Phone(888)657-6527 Fax(805)528-9701 xsn~o\'~nmgnm..vnWncAmgrmM ~NV~ma PLANS REVIEV BOM REVIEWE Plan checker TABLE OF CONTENTS PAGE # DESCRIPTION PV-01 SITE PLAN PV-02 STRUCTURAL DETAIL PV-03 ELECTRICAL DETAIL SYSTEM INFORMATION MAGNETIC TRUE ARRAY I I PITCH ORIENTATION ORIENTATION AR-01 18° 170° 180° 1) 3.08 KW SOLAR SYSTEM INSTALLED BY REC SOLAR CL # 7080 2) SOLAR MODULES MOUNTED FLUSH TO ROOF USING PRO-SOLAR ALUMINUM RACKING SYSTEM. 3) SYSTEM WEIGHT: 3 LB/FTA2 3) 1 STORY COMPOSITE SHINGLE ROOF 4) INVERTER LOCATED IN BASEMENT, NEXT TO MAIN PANEL 5) CONNECT SYSTEM VIA LINE-SIDE FEEDER CONDUCTOR TAP AT METER LOCATION. 6) RUN CONDUIT NORTH EAST IN ATTIC, PUNCH OUT NORTH WALL, & RUN DOWN TO MEET INVERTER (CONFIRM WITH CUSTOMER PRIOR TO CONSTRUCTION). 7 ROOF STRUCTURE: 2" X 4" RAFTERS, 19.2" O.C. PUCKETT RESIDENCE 7425 W. 29TH AVE. WHEAT RIDGE, CO 80033 PV-O1 REV: A 4/9/2009 C m A L n O N Ul C n VICINITY MAP - 'ENGINEER - DRAFTER = DESCRIPTION - 3 BRET MUELLER DAN WHITNEY PHOTOVOLTAIC SYSTEM S TRUC 11- 2111 2 ~ 11-2in CIRCUIT LAYOUT SCALE: 1,4" = 1' REC SOLAR, INC. CUSTOMER APPROVAL CO LIC# 7080 775 Flom Pane, Sults 200 ~jfy~San LWs Obispo, CA 98401 USA PROJECT FOREMAN Wls Obispo,G gmal USA PROJECT FOREMAN dd~~?? Phone(888)657-6527 Faz 805)528-9701 .ww-mm.vrn~w~.~+.~so..+u,.amo.u".~.n+wwomm..evwma+....o PLANS REVIEWED: BOM REVIEWED: Subjec Wheat Building Dept. Date: Plan checker SOLAR MODULE CHANNEL NUT = SOLAR MODULE SUPPORT RAILS FLASHING SOLAR MODULE CLAMP CHANNEL NUT ROOF STANCHION - MOUNTING BASE J I A - ROOF 5/16" STAINLESS STEEL LAG BOLT MINIMUM 2-1/2" EMBEDDING CRAFTER PENETRATION DETAIL NOTES: REC GROUP RE0220AE-USA MODULES 220W MODULES 65.55" X 39.02" X 1.69" NOTES: USE PRO-SOLAR SHALLOW CHANNEL RAIL. MAXIMUM 4' SPAN, MAX OVERHANG 1-1/2'. PUCKETT RESIDENCE 7425 W. 29TH AVE. WHEAT RIDGE, CO 80033 PV-02 REV: A 4/9/2009 e \ Vn O NJ tJl C n 1 ENGI BRET MUELLER DAN WHITNEY PHDT~VULTAIC SYGTEM ELECTRICALD E )TE TQ INSTALLERS: CONNECT VIA LINE-SIDE FEEDER CONDUCTOR TAP AT METER LOCATION 1" EMT OR EQUIVALENT: (2) 2 AWG THHWTHWN-2 CONDUCTORS (1) 2 AWG THHN/iHWN-2 NEUTRAL (1) 8 AWG THHN/THWN-2 GROUND EXISTING CONDUIT 1, CONDUCTORS 1/2" EMT OR EQUIVALENT: (2) 10 AWG THHN/THWN-2 CONDUCTORS LINE-SIDE FEEDER (1) 10 AWG THHN/'I'HWN-2 NEUTRAL CONDUCTOR TAP (1) 8 AWG THHN/THWN-2 GROUND 120/240 VAC SINGLE PHASE SERVICE 100 AMP RATED MAIN 100 AMP MAIN BREAKER FRONIUS IG e o FUSED MANUAL - 3000 INVERTER RESIDENCE DISCONNECT LOCKABLE 2700 WATT (240 V DISCONNECT INVERTE envn, ~ n~ ~ ~ m AC OUT ~ DC IN SQUARE D 200 AMP RATED ENCLOSURE D221NRB 100 RATED MAIN BREAKER NEUTRAL 30A 120/240 VAC 120/240 VAC BUS 15 AMP FUSES GROUND BUS FACILITY ELECTRICAL NOTES: GROUND 1. GROUNDING WIRE WILL BE BONDED DIRECTLY TO FACILITY GROUND 2. ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2008 NEC 250 3. MODULE INTERCONNECTIONS WILL BE MADE WITH 10 AWG RHW/USE-2 WIRE. 4. ARRAY CONDUCTORS ARE SIZED FOR DERATED CURRENT PER STRING 8.20 AMPS SHORT CIRCUIT CURRENT 125% DERATING FOR EXTREME IRRADIANCE CONDITIONS (NEC 690-8 (a)) 125% DERATING, CONTINUOUS PHOTOVOLTAIC SOURCE CURRENT (NEC 690-8 (b)) 1560/a TOTAL DERATING (COMBINATION OF ABOVE) 12.81 AMPS TOTAL CAPACITY (AMPS TOTAL CAPACITY = STRING SHORT CIRCUIT CURRENT MULTIPLIED BY TWO ABOVE DERATES, 1.25 X 1.25 X SHORT CIRCUIT CURRENT) 5. INVERTER PROVIDES NECESSARY GROUND FAULT PROTECTION AS REQUIRED BY 2008 NEC 690.5 GROUND FAULT PROTECTION. 6. PHOTOVOLTAIC SYSTEM HAS CONDUCTOR BONDED TO GROUND IN INVERTER AS REQUIRED BY 2008 NEC 690.41 SYSTEM GROUNDING, AND 690.42 POINT OF SYSTEM GROUNDING CONNECTION. 7. WHERE DC PHOTOVOLTAIC OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING THEY SHALL BE CONTAINED IN A METALLIC RACEWAY OR ENCLOSURE FROM THE POINT OF PENETRATION TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS - 2008 NEC 690.31 (E) 8. USE UL APPROVED BONDING FITTINGS AT ALL CONDUIT/BOX JUNCTIONS. 9. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703 10. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741 REC SOLAR, INC. CUSTOMER APPROVAL 77 CO DC# 7080 775 Rem Lane, Suite 208 i Phone (88San San - Luis 0 Fax 6527 Fax( A 80 )52 93401 USA " 01 PROJECT FOREMAN MODULE CHARACTERISTICS REC GROUP REC220AE-USA 220 watts Open Circuit Voltage 36.6 V Open Circuit Voltage: (NEC 690.7) 45.8 V Max Power Voltage 28.7 V Short Circuit Current 8.20 Amps Short Circuit Current: (NEC 690.8(A)(1)) 10.25 Amps SYSTEM CHARACTERISTICS STICKER System Size 3.08 kW System Open Circuit Voltage 320.3 V System Operating Voltage 200.9 V Max Allowable DC Voltage 500.0 V System Operating Current 15.40 Amps System Short Circuit Current 20.50 Amps LABEL: DC DISCONNECT OR INVERTER PLANS REVIEWED: 1 /-A 1`, Subject to Field Inspections Wheat EMT OR EQUIVALENT: 10 AWG THHN/THWN-2 CONDUCTORS 10 AWG THHN/THWN-2 GROUND 1/2" EMT OR EQUIVALENT: (4) 10 AWG THHN/THWN-2 CONDUCTORS HEAVY DUTY SAFETY ~(1) 10 AWG THHN/THWN-2 GROUND SWITCH, 3-POLE 30A 60OVDC f Building Dept. Plan (14) REC220AE-USA MODULES IN (2) STRINGS OF (7) MODULES EACH 256.2 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE - WARNING - THIS EQUIPMENT IS POWERED BYA PHOTOVOLTAIC POWER SOURCE LABEL: MAIN SERVICE PANEL, EXISTING SUBPANELS, AND EXISTING EQUIPMENT TIED INTO. - WARNING - DO NOT ENTER THIS EQUIPMENT IS POWERED BY A PHOTOVOLTAIC POWER SOURCE LABEL: REC INSTALLED JUNCTION BOXES, COMBINER BOXES AND GUTTER BOXES. PUCKETT RESIDENCE 7425 W. 29TH AVE. WHEAT RIDGE, CO 80033 Date: - WARNING - ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD LABEL: REC INSTALLED SUBPANELS AND FUSE BOXES. PHOTOVOLTAIC DISCONNECT - WARNING - ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED LABEL: AC, DC DISCONNECT OR OTHER DISCONNECTING MEANS. PV-03 REV: A 4/9/2009 V ■ O 1 ,N^ VT1 V Cn BUILDING DEPARTMENT (303) 235-2855 CITY OF WHEAT RIDGE Correction Notice Job Located at 2!V2 S W. ft y A c P- f You are hereby notified to correct the foregoing violations. When corrections have been made, call for inspection. Date DO NOT REMOVE THIS TAG FORM WRB-42 BulMing Dept. 3 1 ~ { ...-.~,u~w.~..~.~.. I have this day inspected this structure and these premises and have found the following violations of City and/or State laws gov- erning same: DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : 95-1122 Date :6/2/95 Property Owner : PUCKETT JOHNATHAN C Property Address : 7425 29TH AV Contractor License No. : 18023 Company : Schroeder Roofing Metro Phone: 237-7497 Phone : 444 3538 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and ayreeto abide by all conditions printed on this C de (U.B~C.and ) and a all otheapplilcable Whe ttRydfor ge ordnlances,fi h o wthe orknder RhispBmiding (OWNER)(CONTRACTOR) SIGNED;r'rM J b M±~,, DATE ' Descriptian : REROOF Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: ~ ~ Ill- gg (1) This permit was issuetl in accortlance with the pmvisions set torih in yopur application and is sub1'ect to the laws of the State ot Coloretlo antl [o the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other appliwble ordinances of the City. (2) This pemiit shall expire rf(A) the work authorized is not commenced within sixly (BO) days trom issue date or (B) the builtling auMOrizetl is suspentletl or abandoned !or a periotl of 120 tlays. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no chanqes have been or will be made in the onginal plans and specifcations antl any suspension or abantlonment has not exceetled one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paitl for a new permit. (4) No work of any manner shall be done that will change the natural Flow of water causing a drainage problem. (5) Contractor shall notiry the 8uilding Inspector twenty-four (24) hours in advance Por all inspedions antl shall receive written approval on inspeclion cartl before proceediing with successive phases ot the1'ob. (6) The issuance ot a permit or the approval of drawings and specifications shall not be wnstrued to be a permit Por, nor an approval of, any violation of the provisions of the puilding code5 or any other ordinancg, law, rule or regulation. Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION Construction Value : $1,890.00 Permit Fee : $45.00 Use Tax : $28.35 Total: $73.35 JUN-01-95 THU 03:45 PM SCHROEDER i 308 344 0922 P aAI ~197 Propelty Ownt! = propeAy Addrass: Cunlrac;tor LKenBe No• ~ ~ CompanY : Phone : Lt-~~d qyVNEWCON11iAC101t SKfNATURE OF UNOERST~DING ~D AC411EMM i n.r■ey aaory 4n~ me sNOxx aiwinco. Aovd+~a er I omni . el Y~M~M en0 aa ool wolalt app4e~bN aOMinGas. NM nui.m~ms sho~+y~n~. pM~dn ~ 7~ coveMnls. e■s■mrnla a 1aslriapm d ~KaO.w ~Ode bv Mi wndil'qm P RIaY~ B~+q nrde ~la IICLWi10. Mal l Aaw nad Mld w~ pN WneK ~pp~K~ilron. snd IhN 1soW~ ~~Mp^gnas. Ia wvAc vn0~►rtl~ PM~' ' CeMIU D.L 1+nd aB WMI ipplie~OM M~MM ~ (qUMiNXCONTRACTON) SIC+NEC~,.-~.--- Descnpiwn ~ • ~ ~ Approval' Za~iny • . , Approval• ApprovW OCCUPancY, Walls : Constnklion VWNm: Pertnit foe ' S. ~ Use Tax : ~ $ 3 S 3 Taw: 3,s ~s OEPAR'CMENT USE ON4Y 8totiez ~ ftsb0rddd UANS: Roof : ~ha~iCa1 LIow Eleolrieai Liwpw Na .Plu(g6in9 License No ~ Compsirw: ComPanY Compiny : ExpiraUan Da1e EzpraGOn Dale' MProval MProval. ig ~pns~te u~ree;{~p! 'Plaas~ R~~ 41) aTMeq`wm inXodeoa. ~ ~aeea~tiawMyw9'°W~~w1~ O Ig 7n.ne~~~nMe.Poa N~~1p1t~ n roli~■ ro~My~wr~MaweenYa yyn~eon.o~aIa1md~ ay1 ~~q o wWu~ena/uniril 1+, '~~+NlMd~p~ww~'dMMdanMa p) « ju' n~ I~qnti~i~d~ swP~n u ~ TM"' ~u. na avwMO 00 pid UAar RKeeatiaw~~ITr+~ Mo10e.Y~Mar~a1 nervn ~Or+MYeP~ n MM~ (q NowaMUlM7n~YwiYWO~dsyYW ~ Mw~~Nai7+~G10l~RM~~~r ~~~dN~p~~'~ ~ i:.w~.o~ua~uo~.ar~eM~MM~~p~ew aq~y'.wM~OM7w p~KOC~.Ww~nwcw~~~~~ywJis~q~ b~ .aMNaaMwm eemwwlN O, W 1M6M~YMI~IIIap/IINY oY~lOIW~ W' ~ W+~ IA MW IMr~MM1. MPY p M( FaM-ryW ~Chu Iluihlin~~ In~MectW AtlC UAAYOR I I lIS 1'1 14 MI t VnLID CA~ ~ w~j~ Sgj~ gq IInURS PR OR TOUN PIE TION ECTOR 7500 WEST29thAVENUE DEPARTMENTOFGOMMUNITYDEVELOPMENT 234-5933 P.o.eOX638 BUILDING INSPECTION DIVISION PERMIT CITY OF WHEAT RIDGE C NO b1M94#4452 , OLO. TNiS PERMIT VALID ONLY WNEN SiGNED BY THE CHiEF BUILDiNG iNSPECTOR AND RECEIP7EDBELOW. JOB n S~ a~ APPUCATION FOR MISCELLANEOUS PERMiT ^ ADDRE n SS c OWNER ~1f /✓v /fefj. CONTRACTOR 6D 2 ~ y ADDRESS /J`7d_S w ~RT~ ADDRESS . ~ C/? ,`~.5~/av( PHONE 23 -J--)StO/~ CITY ✓~6n(,..n4c ZIP CODE -1 U=/ w CONTRACT PRICE $ ~;~j ` ZIPCODE PHONE 232 1' /i LICENSENO. DATE 2- I. TVPE Ground❑ Woll❑ Proleolinp❑ Othn SaDFOu SIGNS 2. MATERIAL To1al Samn Fotl 3. ILWMINATION Yea❑ No❑ Tycs El _ 4 SET BACK FROM PROPERTY LINE N_ 5_ (Speeily whicn is fronf ) ❑ ci I. TYPE SolidO Mon TAan BO% Opan❑ aet. Psrmil M' I Zons_ Apprwed, 2ona Inspector Less Thon 80% FENCES I MATERIAL 3. SET BACK FROM PROPERTY LINE whieh is front OTHER IZ N- S- E- W 2om_ AppraW.Zons Impserw Cl El ❑ ❑ Dinaoereved DRAW SKETCH pFt SHOW BELOW, THE FENCE,516N,OR OTHER STFUCTURE,GIVihu D1514NCES FROM PROPERTV LINES. (SETBACNS OR PROJECTIONS INCLUDED) ~ SPECIFY NORTH STREET NAME SNOW DISTANCES FROM THE MAIN BUILDING TPADJOINING HOUSES, STREETS, AND PROPERiY LINES;ON IRREGULAR IpTS,SHOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM iHE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 180 OAYS FROM THE DATE OF ISSUANCE IF WORK IS NOT STARTED WI7HIN iunr rinnc ELECTRICAL PERMIT PLUMBING PERMIT MECHANICAL PERMIT STATE LICENSE N0. STATE UCENSE N0. ALUM INUMWIREUNDERSIZE81LlEGAL FLOOR BSM IST 2N0 3RD 4TH N0. fUEl:CircNOrwCqyqlRpporr ElecSdor ~ WATER CLASET FORCED AIR - BTU TEMPORARY METER _ WASH BOWL HOT WATER - BTU NEW SERVICE ° AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONINC -BTU IIGHTING SINK OTHER HEATING GARBAGE DISP REFRIGERATION SYSTEM POWER SUB-CIFCUITS WATER HEATER Re}ri eront Group UTILI7Y(RANGE,DISPOSER,E7C) AUTO. WASHER Poundt C~or a FIXTURES DISH WASHER AUTOMATIC SPRINKLER SYSTEM WIRING MOTORS 6 CONTROLS FI.DOR DRAIN EIEVATOR SIGNS URINAL TRANSFORMERS 9 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES REMARKS nL/CA L, CuilNiF<c /+lata R71(f ~ ~"e') f I Mreby ocMnowledqe thot mis apolica- PERMIT FEE tion u corroct ond understand rhat I USE TAX Gannof ttorf thi! OrojbCt until this appli- eotion is approved. I shail compiy witn TOTAL FEE ~ ths lows of 1he Stote ol Colorado ond fo Cy the Zonina Repulations and Buiidinp ApPROVED ? Code of the City ot Wneat Ridqe. Any DISAPPROVED violotion of roe obove terma wdi couse CHIEP BUILDIN I PECTOR,City of Wheat Ridqe immediate revocation of this permit C dd V ih Dafelssued NOT VALID SS?3 CALL 230-5933 24 HOURS IN ADVANCE FOR INSPECTIONS .eore 7 yaw,. DEPARTMENT OF GOMMUNITY DEVELOPMENT BUILDING INSPECTION DIVISION PERMIT N0. ME93#5252 CITY OF WHEAT RIDGE, COLO. THIS PERMIT V N: W SIGNED BY THE CHIEF BUILOING INSPECTOR ANC RECEIPTED BELOW. ' ~Io2 • AppLICATIO FOR ISCELLANEOUS PERMIT~/ / JOB ADDRESS OWNER 1~t y~~t.r7i'a ~v CONTRACTOR - ~ ~ ADDRESS ~`j~ YLorS4':~Iti ADDRES~ < <I ~ PHONE / ZIP CODE CITY ZIPCODE .Cl(.1-4-T) CONTRACT PRICE $ _ •~~C~~YPHONE LICENSE NO. DATE 1. TYPE Grountl Woll❑ Proistlinp❑ Othtr SMDFeN 2. MATERIAL -1 To1ol Squore FeN SIGNS 3. ILLUMINATION YeS No❑ 7ypa_Tl,ih e c1~. } Etk}. Permif No. 4. SET BACK FROM PROPERTY LINE N_ S_ E__ W Zpne_ pppra,b Zone insacta (Spxify whioh ia front) ❑ ❑ ❑ Disopprwed 1. TYPE SolidO Mon TMn BO% Opan❑ Lost Thon 80% Open FENCES ? MATERIAL H~ipM 3. SET BACK FROM PROPEIt7Y LINE N_ S_ E_ W 2me_ ADOrwW,Zon~ I~~p~etor ($pecify whicA ie front) Q ❑ ❑ ❑ Disapproved I. OTHER 2 a. DRAW SKETCH pR SHOW BELOW, THE FENCE, SIGN, OR OTHER STRUCTURE,GIVING OISTANCES FRpM PRQpERTV LINES. (SETBACKS OR PROJECTiONS INCLUDED) ~ SPECIFY NORTH STREET NAME SNOW OISTANCES FROM TF1E MAIN BUILDING TQADJOININ6 HOUSES, STREETS, AND PROPERTY LINES;ON IRREfiULAR LATS, SYIOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR pVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UVON VALIDATION BY THE BUILDING INSPECTION DIVISION. . PERMIT WILL EXPIRE 180 DAVS FROM THE DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN THA771MF ELECTRICAL PERMIT STATE LICENSE NQ PLUMBING PERMIT S7ATE LICENSE N0. MECHANICAL PERMIT ALUMINUMWIREUNDERSIZE81LlEGAL NO. FLOOR WATER CIASET BSM IST 2N0 3RD 4TH N0. FUELCirJaOrnGoypl ftPorislCoolilEleclSolor FOpCED AIR - gTU TEMPORARY METER WASH BOWL HpT WATER - BTU NEW SERVICE - AMPS CHANGE SERVICE-AMPS LIGHTING BATH T118 SMOWER SINN STEAM - BTU AIR CONDITIONING-BTU OTHER HEATING GARBAGE DISP REFRIGERATION SYSTEM POWER SUB-CIFCUITS UTILITY(RANGE,DISPO5ER,ETC.) WATER HEATER AUTO. WASNER Rafri sranl Grpup pW~s harge FIXTURES DISH WASHER AUTpMATIC SPRINNLER SYSTEM WIRING MOTORS B CONTROLS FLOOR DRAIN EIEVATOR SIGNS URINAL TRANSFOFMERS d RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES REMARNSttCk.j i I hsreby acknowledQe thot ihis applica- tion u Cwretf ond understand ihot I connof simt thie projbCt until thia appli- eation is approveA. I sholl comply wrtA the laws of the Stafe ol Colorado and 10 the ZoninQ ReQulaliona ond Buildinp Lode ofthe City of Wneat Ridqe. Any violo}ion of the above terms wdt couse immediote revocaFOn of this permil / i PERMIT FEE NOT VALID UNLESS USE TAX TOTAL FEE APPROVE ~ CFJ~ ~ . b ,i~iA~R6tJED <ri - CHIEF BUILDIN NSPECTOR,City of W ot Ridqe c ~ Date Issued DEPARTMENT OF COMMUNITY DEVELOPMENT 7500 WEST 29tn AvENUE BUILDING INSPECTION DIVISION PERMIT N0. M92#18528 237-6944 ExT. 255 P.O. Box 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SiGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED BEIOW. PPUCATION FOR MISC ELLANEOUS PERMIT JOB ADDRESS ~ Tz ~ W Z!r ~Y OWNER ~C' c/ 2 Z ~ 4 EL CONTRACTOR ADDRESS / 1 - ADDRESS 7y7. '5G~I_ ZIP CODE 90211 CITY !i.l~^c, (ZT A9106Y~E ZIP CODE VdOZ~.~ ~ONTRAGT PRICE $ PHONE Z37-7VCI2 LICENSE NO. 1. TYPE Ground❑ Wall❑ Proitclina❑ Olher SaOFate 2. MATERIAL Total Squan Faat . SIGNS 3 ILLUMINATION Yes❑ No❑ Typa Permif No Eleef . 4 SET BACK FROM PROPERTY LINE N (SDecify whicA ia front ) _ ❑ S_ ❑ E_ W ❑ ❑ . Zong . _ Approved, Zone Incpector Dieopproved ~ 1. 2 TYPE Solidg] Mon Thon 80% OpsnO MATERIAL L(7AR Leu TAan 80% Open Hdph~ FENCES . 3 SET BACK FROM PROPERTY LINE N (Specity whiehiafront) ❑ S~ ❑ E6;1:2 W ❑ ❑ Zorn ~ApprwM,Zono Inspetta Disapproved I c . Z e ~ OTHER a . ~ 2 , 5 DRAW SKETCH OR SNOW BELOW, THE FEN EiIGN, OR OTHER STRUCTUF~E GNIh'u DISTANCES FRdA PROPERTY LINES. (SETBACKS OR PROJECTIONS INCLUDED) ~ REAR PROPERTY LINE z J J > Y ~ ~QA/C°& 5i• 0 ~ SPECIFV NORTH a ~ ~z 91 _1`% l/C STREET NP.ME SHOW DI5TANCES FROM THE MAIN BUILDING TOAWOINING HOUSES, STREETS, AND PROPERTY LINES; ON IRREGULAR LATS, SHOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 60 DAYS FROM DA'fE OF i5$UANCE !F WORK IS NOT STAHTED WITHW THAT TIME. FLECTRICAL PERMIT STATE I_ICENSE N0. PLUMBING PERMIT STATE LtCENSE N0. MECHANICAL PERMIT ALUMINUMWIREUNDERSIZE8ILLEGAI FLOOR BSM IST 2ND 3RD 4TH N0. FUEL:CircJaQrCwfOll EleeSdar Np. TEMPORARY METER NEW SERVICE AMPS WATER CLASET WASH BOWL BATN TUB FORCED AIR - BTU HOT WATER - BTU STEAM - BTU CNANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTING SINK OTHER HEAI"ING GARBAGE DISF REFRIGERATION SYSTEM POWIER SUB-CIFCUITS WATER HEATER Retri erant Group UTILITY (RANGE, DISPOSER, ETC.) AUTO. WASHER Pounds CMr e fIXTURES DISH WASHER AUTOMATIC SPRINKLER SYSTEM WIRING MOTORS 9 CONTROLS FLOOR DRAIN ELEVATOR SIGNS URINAI TRAIVSFORMERS 9 RELTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTJRS OVER I HP TOTAL FIXTURES I hareby ocknowledae thot this appllca- fion is eorrr.ct and undersfand thot I connot afarf this projecf until thia opDli- cotion ia approved. I shall comply with fhe lowe of the S4ote ol Colorado and to tha Zoninp IReQulationa ond Buildinq Code of fl+e City of Wheat Ridqe. Any violafion of 1he above terma will causa immediate revocation of this permit. aop7a0. PERMIT FEE USE TAX TOTAL FEE-1 A < $ ~av.bl VALID UNL'2a 451 CHIEF BJ~LDING INSPECTOR,City of V1Wheat Ridge / Date Issued CALL 237-8944 EXT. 255 24 HOURS IN ADVANCE FORINSPECTIONS