HomeMy WebLinkAbout10700 W. 38th AvenueFIRESTONE WARRANTY GENERAL TERMS, CONDITIONS AND LIMITATIONS Warranty No: 700335039 Project No: 2958210 Start Date: 01/31/2018 Building Identification: 10600 & 10700 W 38th Ave Building Address: 10600 W. 38th Ave, Wheatridge, CO 80033 Building Owner: 10600 &amp; 10700 W 38th Ave Roofing Contractor: THE BAUEN CORPORATION, 40000145 Subject to the terms, conditions, and limitations set forth herein, Firestone Building Products Company, LLC ("Firestone"), an Indiana limited liability company, provides the Building Owner ("Owner") named above with this Limited Warranty for the Firestone provided System(s) or Material(s) set forth herein. This Warranty consists of multiple pages, all of which comprise the express terms and conditions of the warranty herein. Additional requirements, terms, conditions, exceptions, and limitations are defined in subsequent pages. In the event that any inconsistencies exist between the General Terms, Conditions and Limitations listed below and the Terms, Conditions and Limitations in subsequent pages, the subsequent pages will prevail. GENERAL TERMS, CONDITIONS AND LIMITATIONS MPayment Required. Firestone shall have no obligation under this Limited Warranty unless and until Firestone and the licensed applicator have been paid in full for all supplies, services, approved written change orders, warranty costs and other costs which are included in, or incidental to, the System or Materials. In the event that repairs not covered by this Limited Warranty are necessary in the future, Firestone reserves the right to suspend this Limited Warranty until such repairs have been completed and the licensed applicator and/or Firestone has been paid in full for such repairs. Exclusions. Firestone shall have no obligation under this Limited Warranty, or any other liability, now or in the future if a claim or damage is caused by: Natural forces, disasters, or acts of God including, but not limited to, fires, hurricanes, tornadoes, wind-blown debris, lightning, earthquakes, volcanic activity, atomic radiation, insects or animals; Act(s), conduct or omission(s) by any person, or act(s) of war, terrorism or vandalism, which damage the System or Material or which impair the System or Material's ability to perform properly; Failure by the Owner to use reasonable care in maintaining the System or Material, said maintenance to include, but not be limited to, those items listed in the current version of the Firestone Owner's Manual available at http://firestonebpco.com/ in the Building Owner's Toolbox; Deterioration, defects or failure of building components, including, but not limited to, the substrates, structural elements, walls, mortar, HVAC units, skylights, foundation settlement, etc.; Construction generated moisture, condensation or infiltration of moisture in, from, through, or around the walls, copings, rooftop hardware or equipment, skylights, building structure or underlying or surrounding materials; Acid, oil, harmful chemicals, or the reaction between them; Alterations or repairs to the System or Materials that are not completed in accordance with Firestone's published specifications, not completed by a Firestone licensed applicator, and/or completed without proper notice to Firestone; The design of the system: Firestone does not undertake any analysis of the architecture or engineering required to evaluate what type of System, Installation or Material is appropriate for a building and makes no warranty express or implied as to the suitability of its Products for any particular structure; such a determination is the responsibility of the architect, engineer or design professional; Improper selection of materials for the assembly or the failure to accurately calculate wind uplift and/or applicable design loads; Deterioration to metal materials and accessories caused by marine salt water, atmosphere, or by regular spray of either salt or fresh water; Failure of any non -Firestone brand materials used in the Firestone System or Installation not specifically accepted in writing by Firestone to be included in coverage; Change in building use or purpose; Failure by the Firestone licensed applicator or any additional contractor or subcontractor to follow Firestone's recommended installation instructions or approved specifications or drawings for the layout, design, and installation of the System or Materials. It shall be the Firestone licensed applicator's sole and exclusive responsibility to strictly follow Firestone's recommended installation instructions or approved specifications or drawings for the layout, design, and installation of the System or Materials; or Failure to correct all installation deficiencies listed in any Firestone inspection report. Overburden. Owner shall be responsible for the costs associated with the removal and replacement, as well as any damage caused by the removal and replacement, of any overburden, superstrata or overlays, either permanent or temporary, which include but are not limited to: structures or assemblies added after installation, fixtures or utilities on or through the System or Material, support platforms or bases for Photovoltaic (PV) Arrays (aka - Solar Panels), Garden Roofs, Decks, Patios or any other obstacles that impede access, clear observation, investigation, and repair of the System or Materials, excluding ballast or pavers accepted by Firestone or overburden specifically included in subsequent pages of this Warranty. Term. The term of this Limited Warranty shall be for the period set forth above and in subsequent pages of this document and shall not be extended under any circumstances without Firestone approval. Access. During the term of this Limited Warranty, Firestone's designated representative or employees shall have free access to the Installation location for inspection, audit, or repair purposes during regular business hours. In the event that access is limited due to security or other restrictions, Owner shall reimburse Firestone for all reasonable cost incurred during inspection and/or repair of the System or Material that are due to delays associated with said restrictions. Waiver. Firestone's failure to enforce any of the terms or conditions stated herein shall not be construed as a waiver of such provision or of any other terms and conditions of this Limited Warranty. Disputes. Any dispute, controversy or claim between the Owner and Firestone concerning this Limited Warranty or relating to any material supplied or specifically required by Firestone shall be settled by mediation. The Owner hereby releases Firestone from all liability to Owner's insurance carrier or to anyone claiming under or through Owner by reason of subrogation or otherwise. In the event that the Owner and Firestone do not resolve the dispute, controversy or claim in mediation, the Owner and Firestone agree that neither party will commence or prosecute any suit, proceeding, or claim other than in the courts of Hamilton County in the state of Indiana or the United States District Court, Southern District of Indiana, Indianapolis Division. Each party irrevocably consents to the jurisdiction and venue of the above -Identified courts. Governing Law, This Limited Warranty shall be governed by and construed in accordance with the laws of the State of Indiana without regard to its rules on conflict of laws. Severability. If any portion of this Limited Warranty is held by a court of competent jurisdiction to be invalid, void or unenforceable, the remaining provisions shall nevertheless continue in full force. FIRESTONE DOES NOT WARRANT PRODUCTS INCORPORATED OR UTILIZED IN THIS INSTALLATION THAT WERE NOT FURNISHED BY FIRESTONE. FIRESTONE SPECIFICALLY DISCLAIMS LIABILITY UNDER ANY THEORY OF LAW ARISING OUT OF THE INSTALLATION OF, PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS NOT FURNISHED BY FIRESTONE. THIS LIMITED WARRANTY SUPERSEDES AND IS IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND FIRESTONE HEREBY DISCLAIMS ALL SUCH WARRANTIES. THIS LIMITED WARRANTY SHALL BE THE OWNER'S SOLE AND EXCLUSIVE REMEDY AGAINST FIRESTONE, AND FIRESTONE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL, INCIDENTAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR DAMAGES TO THE BUILDING OR ITS CONTENTS, SUBSTRATES OR THE ROOF DECK. THIS LIMITED WARRANTY CANNOT BE AMENDED, ALTERED OR MODIFIED IN ANY WAY EXCEPT IN WRITING SIGNED BY AN AUTHORIZED OFFICER OF FIRESTONE. NO OTHER PERSON HAS ANY AUTHORITY TO BIND FIRESTONE WITH ANY REPRESENTATION OR WARRANTY WHETHER ORAL OR WRITTEN. THIS WARRANTY INSTRUMENT CONSISTS OF MULTIPLE PAGES, ALL OF WHICH ARE PART OF THIS DOCUMENT. ADDITIONAL REQUIREMENTS ARE DEFINED ON SUBSEQUENT PAGES. 200 4th Avenue South, Nashville, TN 37201 1-800-428-4442 T` rQ sto n e www.firestonebpco.com BUILDING PRODUCTS Page 2 of 3 NOBODY COVERS YOU BETTER." 1001.001.2015 FIRESTONE RED SHIELD ROOF SYSTEM LIMITED WARRANTY Warranty No: 700335039 Project No: 2958210 Start Date: 01/31/2018 Building Identification: 10600 & 10700 W 38th Ave Building Address: 10600 W. 38th Ave, Wheatridge, CO 80033 Building Owner: 10600 &amp; 10700 W 38th Ave Roofing Contractor: THE BAUEN CORPORATION, 40000145 ROOF-TPO Firestone Red Shield - TPO - 20 Year - 55 mph Firestone Red Shield - TPO - 20 Year - 55 mph Square Footage: 10,200 Square Footage: 21,650 D For the warranty period indicated above, Firestone Building Products Company, LLC ("Firestone"), an Indiana limited liability company, warrants to the Building Owner ("Owner") named above that Firestone will, subject to the Terms, Conditions and Limitations set forth below, provide labor and material to repair any leak in the Firestone Roofing System ("System") caused by deterioration in the Firestone brand material due to normal weathering or any manufacturing or workmanship defect in the membrane within the scope of this warranty during the period specified above. TERMS, CONDITIONS AND LIMITATIONS Products Covered. The System shall mean only the Firestone brand roofing membranes, Firestone brand roofing insulations, Firestone brand roofing metal, and other Firestone brand roofing accessories when installed in accordance with Firestone technical specifications by a Firestone -licensed applicator. Any materials not manufactured or supplied by Firestone are not covered under this warranty. Notice. In the event any leak should occur in the System, the Owner must give notice in writing or by telephone to Firestone within thirty (30) days of any occurrence of a leak. By so notifying Firestone, the Owner authorizes Firestone or its designee to investigate the cause of the leak at its option. Investigation. Should the investigation reveal that the leak is excluded under the Terms, Conditions and Limitations, the Owner shall be responsible for payment of the investigation costs. Failure by Owner to pay for these costs shall render this Limited Warranty null and void. The Owner is responsible for completing repairs not covered by the Limited Warranty to be made at the Owner's expense that will permit this Limited Warranty to remain in effect for the un -expired portion of its term. Failure by the Owner to properly make these repairs in a reasonable manner using a Firestone -licensed applicator and within 60 days shall render this Limited Warranty null and void. No Dollar Limit (NDL). If upon investigation, Firestone determines that the leak is not excluded under the Terms, Conditions and Limitations set forth in this Limited Warranty, the Owner's sole and exclusive remedy and Firestone's total liability shall be limited to the repair of the leak. There is no dollar limit placed on warranted leak repairs to the extent such repairs are covered by this Limited Warranty. Exclusions. Firestone shall have no obligation under this Limited Warranty, or any other liability, now or in the future if a claim or damage is caused by: Hail Winds of peak gust speed at or in excess of 55 mph calculated at ten(10) meters above ground using available meteorological data: (All associated building components, including but not limited to the deck substrate, joists, columns and foundation, must also meet wind speed design requirements); Roof traffic or storage of materials or equipment on the roof not specifically accepted in writing by Firestone. Damage to the roof incurred during breach, rupture or failure of any building envelope component during a flood or wind event not covered under warranty; or, Failure to give proper notice as set forth in paragraph above. Transfer. This Limited Warranty shall be transferable and assignable subject to Owner's payment of the current transfer fee set by Firestone. Alteration. Owner shall obtain Firestone's written approval before making any alterations to the roof system or installing any structures, fixtures, or utilities on or through the roof. This includes modification of the Firestone roof system to serve as a support platform for Photovoltaic (PV) Arrays (aka - Solar Panels), Garden Roofs, Decks, Patios, and areas intended for public access. Roof modification approval typically requires owner sponsored enhancement of the roof system to meet additional performance requirements to ensure service life following the proposed modification. Firestone is the sole judge of whether or not enhancements to the roof system are required. Failure to obtain Firestone approval for a roof modification will result in invalidation of this warranty. FIRESTONE BUILDING PRODUCTS COMPANY, LLC By: Ben George Authorized p Signature: ✓ _ _ Title: Manager, Technical Building Solutions THIS WARRANTY INSTRUMENT CONSISTS OF MULTIPLE PAGES, ALL OF WHICH ARE PART OF THIS DOCUMENT. ADDITIONAL REQUIREMENTS ARE DEFINED ON SUBSEQUENT PAGES. 'firestone BUILDING PRODUCTS NOBODY COVERS YOU BETTER? Page 3 of 3 1003.001.2015 The City of Wheat Ridge Third Party Form Check list Property Address li�'�d ® r. -a_ 4 Permit Number�p � ��o Permit Issued Date 1 1 _ 2 1 Owner Information Property Owner Information Property Owner Address Inspector Information Inspection Company Inspector blame Inspector Contact info_ v„ Garry Manlove JOA Consuttln9 PO. Box 283 o n° + yR Larkspur, Co 801 18 Cell 720443.8280 Email gary manlore.�gmailcom Inspector Statement and Acknowledoement hearty acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. R I hearty acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as allWy of Wheat Fridge Policies and Procedure and Manufacturer's recommendati and Inspector: . Page 1 of 2 Date:. 12 - ) S• *1 hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection lieu of the City of Wheat Rid spection. Propery Owner/Agent: Date: Z2 — This original document and permit card, as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W 20th Ave Wheat Ridge CO 80033 Draft Date: 7/26/17 The City of WheatRidge Inspection Checklist Notes -'t,, Ni'A WA4J�` P-7.-,-, Ifie Roofs R F--'] WA "Cri patq Company Name: JB Inspector Signature: Date of MID -ROOF Ii Fail Fail rail Page 2 of 2 The City of Wh-eat Ridge ZI n s on Checklist Ni otes FINAL Structural roof components Verify that no more than 2 layers of shingles exist Flashing for roof and walls If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted), Verify sheathing nail pattern (See Policy & Procedures) Crickets and saddles where needed Verify B vent must have boot same gauge as pipe Verify vent caps Verify no flashings are damaged or rusted Step Bashing shall be min- of 4x4 piece per shingle Verify scuppers allow, for proper drainage Ice and water shield 2' in heated wall spaces Underlayments must follovd, 2012 IRC 12012 IBC Verffij roof slope for proper drainage Dripedge shall have min of 2" overlap Dripedge should extend dovm min 2" past. roof deck Dripedge shall be mechanicaly fastened 12" OC 90 LB roll rooting shall not be applied to roof slopes less than 2:12 slope: Exceplion, detached garages, patios,, carports, open on three sides with min.. slope of 1:12 Modified Bitumen, EPDM, TPO min stupe 114:1.2 slope Above roof insulation R-25 Bellove roof residential R-38 Below roof commercial R-32 Modified Bitumen, EPDM, TPC} min slope 1f4.-12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final, inspection Metal roof shingles shall not be installed on slope less 3-12 Metal valley flashing shall be the same material as roof Metal valley flashing shall extend a min of 8" from the centeFline,li,vith a min- of 314 " high splash dive rter rib built-in at the flow line with sections overlapping a a min- of 4" Clay and concrete tie shall have a min. 2-112:12 slope Slopes 4-12 and under require double underlayment Company Name: J8AjC4D#4AULTI Inspector Signatu Date of FINAL Inspection: [2- Ro-of Ins vection F71 n."A mr-0. Fall P. NO �Pa-m F. i i U,A L_Pds_" rdij tJ r— El Pass D rail 25_NA_ Fail I--] UiA rail 171 i s I rail 1__J WA LL:l , P Fail M"A Q rail M,;A Fail EJ-fz�'- El rail FA UiA Yz-Pas-s 0 rail 0 ft,' -A E_1_1`PZK'; E] Fall El neix E�"­PaWi El rail r_1 UJA l sa EJ rda wA 2_1�1_pasl; E] Fail MIA F_4-�.,, 0 Fail POWs rail !T� [7 Pates 171 rail A Vass LJ Fail pass El rail t4'. P.W% ®Earl Fars] Fail Ni'A WA4J�` P-7.-,-, Ifie Roofs R F--'] WA "Cri patq Company Name: JB Inspector Signature: Date of MID -ROOF Ii Fail Fail rail Page 2 of 2 The City of Wh-eat Ridge ZI n s on Checklist Ni otes FINAL Structural roof components Verify that no more than 2 layers of shingles exist Flashing for roof and walls If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted), Verify sheathing nail pattern (See Policy & Procedures) Crickets and saddles where needed Verify B vent must have boot same gauge as pipe Verify vent caps Verify no flashings are damaged or rusted Step Bashing shall be min- of 4x4 piece per shingle Verify scuppers allow, for proper drainage Ice and water shield 2' in heated wall spaces Underlayments must follovd, 2012 IRC 12012 IBC Verffij roof slope for proper drainage Dripedge shall have min of 2" overlap Dripedge should extend dovm min 2" past. roof deck Dripedge shall be mechanicaly fastened 12" OC 90 LB roll rooting shall not be applied to roof slopes less than 2:12 slope: Exceplion, detached garages, patios,, carports, open on three sides with min.. slope of 1:12 Modified Bitumen, EPDM, TPO min stupe 114:1.2 slope Above roof insulation R-25 Bellove roof residential R-38 Below roof commercial R-32 Modified Bitumen, EPDM, TPC} min slope 1f4.-12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final, inspection Metal roof shingles shall not be installed on slope less 3-12 Metal valley flashing shall be the same material as roof Metal valley flashing shall extend a min of 8" from the centeFline,li,vith a min- of 314 " high splash dive rter rib built-in at the flow line with sections overlapping a a min- of 4" Clay and concrete tie shall have a min. 2-112:12 slope Slopes 4-12 and under require double underlayment Company Name: J8AjC4D#4AULTI Inspector Signatu Date of FINAL Inspection: [2- PERMIT: )//G 2Z2 ADDRESS:�Z' JOB CODE: 0iz Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Land scape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection J Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business da PERMIT'-�� �2�ADDRESS: /�10P' 6014I'C -JOB COD �f .~ `, / C / Foundation Inspections Date Inspector Initials Comments � 102 Caissons / Piers �J 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wal! insulation AA��P�TjtM�S Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground I Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. AA��P�TjtM�S 206 Water Underground / f %��-� %Zj iZD Ana 1w5/x-am ASU dYQ Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation AA��P�TjtM�S '306 Mid -Roof / f %��-� %Zj iZD Ana 1w5/x-am ASU dYQ 307 Metal / Lath / Stucco (IK 308 Rough Electrical Residential 309 Rough Electrical Commercial '10 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day, PERMIT ) �2�ADDRESS:.1 �C7C��1 % �1 J4 Z� JOB CODE:/ Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wal! insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground (D0 J -� %fij Rp huslqzQ Aftl dye, Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof (D0 J -� %fij Rp huslqzQ Aftl dye, 307 Metal / Lath / Stucco �Jsir c 308 Rough Electrical Residential 309 Rough Electrical Commercial "10 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS PERMIT:WG 9Z2 ADDRESS: CODE: Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning" Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works' 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. Page 1 of 2 The City of Wheat Ridge Third Party Form Check List Property Address i0 74 Permit Number Number Permit Issued Date 1 ► _ 22' i :3 - Owner Information Property Owner Information Property Owner Address Inspector Information Inspection Company Inspector Name Gary Manlove A' 16P3 R-283 Inspector Contact info- eox218 Larkspur.CO 89118 C" 7204438280 Email gary manlovv��gmailcom Inspector Statement and Acknowledgement " I hearty acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6112 must be inspected by the City of Wheat Ridge Buiding Dept. R I hearty acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as al"v of Wheat Ridge Policies and Procedure and Manufacturer's 9. Emu J" 'PITF-314 Alka Date: 47- - 1 5-• / .� kl hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection lieu of the City of Wheat Rid 7spection. Propery Owner/Agent: _ Date: This original document and permit card, as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W 29th Ave Wheat Ridge CO 80033 Draft Date- 7/26/17 11Y"� The City of Wheat Ridge Inspection Checklist Notes - MID -ROOF FI wA -1 I_ wA . Pa— El Fall �J Fail [� rail ,K2C)l �-OCJ 2-23 The City of Wh Ridge Ins on Checklist Notes FINAL Page 2 of 2 Structural roof components Verify that no mare than 2 layers of shingles exist Flashing for roof and walls If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Verify sheathing nail pattern (See Policy & Procedures) Crickets and saddles where needed Verify B vent must have boot same gauge as pipe Verify vent caps Verify no flashings are. damaged or rusted Step flashing shall be min. of 4x4 piece per shingle Verify scuppers allow for proper drainage Ice and water shield 2' in heated wall spaces Underlayments must follow 2012 IRC 12012 IBC Verify roof slope for proper drainage Dripedge shall have ruin of 2" overlap Dripedge should extend down rain 2" past roof deck. Dripedge shall be mechanica y fastened 12" CSC 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, opera on three sides with min. slope of 1:12 Modified Bitumen; EPDM, TPO thin slope 1f4:12 slope ,above roof insulation R-25 Belove roof residential R-33 Below roof commercial R-32 Modified Bitumen, EPDM, TPO rain slope 114:12 scope must be installed in accordance v&M the manufacturers specifications- Must have manufactures letter of warranty vdth the address on the letter for final inspection Metal roof shingles shall not be installed on slope less 3.12 Metal valley flashing shall be the same material as roof Metal valley flashing shall extend a min of 8" from the centerline with a mita_ of 314 " high splash diverter rib built-in at the flown line with sections overlapping a a mire. of 4" i_.1 f_- Pa �" _, z= ,,. Clay and concrete the shall have a min. 2-112:12 slope c--�"- "--Slopes 4:12 and under require double underlayment Company Name: JBA NSULT G Company Name: JBA ULTI Inspector Signature: Inspector Signature Date of MID -ROOF Inspecti Date of FINAL Inspection: �Z R.oDf Inspection I-'7 w'A ,� Vass ❑ Pail P ❑ Fill ❑ hi,%Alt- Pass n Fas: I"firms. I_..I rdil E rasa ❑ Fall }d, .A ❑ Fail WA baa:. 3 [ ] rail f�7 w;� I�: - ❑ Fa,l 1. ] H,'A Pa:t ❑ Fail ❑ tvA ❑ Fail ❑ HI A ^s i � Fail EJ_tZ'A fi•^ L_ Pd" ❑ rail f -A Ni A 7L'- bass ❑ rail Li n.0A °P7cS ❑ Fail ❑ U'A ! Pas UI Fail ❑ tdlA Ll rdii t ,.% 3s1 ❑ Fa.i ❑ H,fA �y Pa.,, ❑ Fail Pazi FI Fail Paz: rail Pa" LJ rdil pas ❑ Fad Pm ❑ Fail L g Pae [—] rail FI wA -1 I_ wA . Pa— El Fall �J Fail [� rail ,K2C)l �-OCJ 2-23 The City of Wh Ridge Ins on Checklist Notes FINAL Page 2 of 2 Structural roof components Verify that no mare than 2 layers of shingles exist Flashing for roof and walls If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Verify sheathing nail pattern (See Policy & Procedures) Crickets and saddles where needed Verify B vent must have boot same gauge as pipe Verify vent caps Verify no flashings are. damaged or rusted Step flashing shall be min. of 4x4 piece per shingle Verify scuppers allow for proper drainage Ice and water shield 2' in heated wall spaces Underlayments must follow 2012 IRC 12012 IBC Verify roof slope for proper drainage Dripedge shall have ruin of 2" overlap Dripedge should extend down rain 2" past roof deck. Dripedge shall be mechanica y fastened 12" CSC 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, opera on three sides with min. slope of 1:12 Modified Bitumen; EPDM, TPO thin slope 1f4:12 slope ,above roof insulation R-25 Belove roof residential R-33 Below roof commercial R-32 Modified Bitumen, EPDM, TPO rain slope 114:12 scope must be installed in accordance v&M the manufacturers specifications- Must have manufactures letter of warranty vdth the address on the letter for final inspection Metal roof shingles shall not be installed on slope less 3.12 Metal valley flashing shall be the same material as roof Metal valley flashing shall extend a min of 8" from the centerline with a mita_ of 314 " high splash diverter rib built-in at the flown line with sections overlapping a a mire. of 4" i_.1 f_- Pa �" _, z= ,,. Clay and concrete the shall have a min. 2-112:12 slope c--�"- "--Slopes 4:12 and under require double underlayment Company Name: JBA NSULT G Company Name: JBA ULTI Inspector Signature: Inspector Signature Date of MID -ROOF Inspecti Date of FINAL Inspection: �Z L City of Wheat Ridge r Commercial Roofing PERMIT - 201709223 PERMIT NO: 201709223 ISSUED: 11/22/2017 JOB ADDRESS: 10700 W 38th AVE EXPIRES: 11/22/2018 JOB DESCRIPTION: Commercial reroofing permit remove existing asphalt shingles, install new felts and flashings. Install new Certainteed Landmark Dimensional Asphalt Shingles. Pitches are 4/12, 8/12 and 24/12 Mansard roof. Includes garages. Total 181squares. *** CONTACTS *** OWNER (303)887-4754 FICCO BROTHERS SUB (303)466-7386 Bob Bellitt 018626 Arapahoe Roofing & SIM *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 104 / BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 62,739.00 FEES Total Valuation 0.00 Use Tax 1,317.52 Permit Fee 834.20 ** TOTAL ** 2,151.72 *** COMMENTS *** *** CONDITIONS *** In order to pass a final inspection on commercial elastomeric or similar type roofing, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and Mid -roof inspections may be called in at the same time, 100 percent of the sheathing must be complete and 25-75 percent of the midroof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. City of Wheat Ridge Commercial Roofing PERMIT - 201709223 PERMIT NO: 201709223 ISSUED: 11/22/2017 JOB ADDRESS: 10700 W 38th AVE EXPIRES: 11/22/2018 JOB DESCRIPTION: Commercial reroofing permit remove existing asphalt shingles, install new felts and flashings. Install new Certainteed Landmark Dimensional Asphalt Shingles. Pitches are 4/12, 8/12 and 24/12 Mansard roof. Includes garages. Total 181squares. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. 1 further attest that I am legally authorized to include alI entities named within this document as partes to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. /V Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying Flans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance_or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code` r any ordina r regii4ti of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of /W heat j_i jgie MUNITy DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(cDci.wheatridge.co.us FOR OFFICE USE ONLY Date: j / J ' ) 11-7 Plan/Permit #� '' � —7 Plan Review Fee: Al f ---7 /7 Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: In 7-6 (D L') • � &�'- <S* Property Owner (please print): �i e- 5-04'LIX.c C-- S Phone: Property Owner Email: I o'j -�t c C'c, (-P a O I , Ccs `—" Mailing Address: (if different than property address) Address: 3 � SO U Kc, 0 � � , City, State, Zip: �-� �c (� 4 C,0 . 6 S Arch itect/Engineer: Architect/Engineer E-mail: Contractor: e Phone: .-�- i-('(_4_( Contractors City License #: O ( '� G �- (o Phone: 3 0 3 - K b (o -- '-?- 3 R (- Contractor E-mail Address: 1 D (^u'^ (P Ct oe vU o o c� Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE R COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. Ft./LF �Gc lu O v C Q K Sic `4lI 1 C Heti,. l�.cc�ct•-s ��a�c. s Btu's Gallons Amps Squares 18 k Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ (0 D , —*� —( , uJ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) CONTRACTOR or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): V DATE: (I a (( ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ Jul 19 17 10:57a Ficco Brothers 3034209621 p.8 ARAPAHOE ROOFING & SHEET METAL, INC. 1501 South Arthur Avenue Louisville, CO 80027 Ph. (30.3) 466-7386 Fax (303; -66-7385 %Y,Nw. arapahoe roofing. cc m July 7, 2017 Tony Ficco 3650 Vance St., Suite 1 Wheat Ridge, CO. 80033 Project: 10700 W. 381h St. Dear Sir_ Arapahoe Roofing and Sheet Metal, Inc. has examined the roofs at the above project and proposes the following options for your review and consideration: Sbin�je Roofing: ➢ Remove the existing asphalt shingles. ➢ Install new 30# UL approved base felt. ➢ Install new 904 rolled roofing 36" in all valleys per local building codes. ➢ Install all necessary roof related metal flashings per local building codes and manufacturer specifications. ➢ Install new pipe flashings and roof vents as necessary per local building codes. Install new 30 yr. dimensional shingles, starter strip and hip & per local building codes. ➢ Price includes the mansard roof and both detached garages. TOTAL SHINGLE ROOF PRICE: $62,739.00 Gutters- ➢ Remove the existing gutters and downspouts (on the garages). ➢ Install new 5" seamless gutters and 2" x 3" downspouts per local building codes. TOTAL GUTTER PRICE: $3,825.00 Jul 19 17 10:57a Ficco Brothers 3034209621 p.9 Page Two July 7, 2017 14700 W. 38" St. The following items are included in this proposal: 1. All material required to do a complete job. 2. All labor to perform the work done by Arapahoe Roofing employees (no subcontractors). 3. Removal of all trash and debris created by our work. 4. All necessary building permits and inspections. 5. All necessary licenses, taxes and insurance. 6. Two year warranty on materials and workmanship. This price is good for 30 days. If this proposal is acceptable to you, please sign this letter and return it to us. If you have any further questions, please contact us at 303-466-7386 x 127. Constructively yours, r� J01111 Wcr� Estimator I Project Manager I wish to schedule the above work and agree to the terms and conditions on the reverse of this estimate. ACCEPTED:�DATE: % �` N 4w "T' - �?, "\� 1.. 1, '�M ' ;,-- 7 cc 00 — U Oto o w �d 7 00 o o Q� O r o U cD h L C r t co e 00 _. .. r E O — x 22 E ri E _M C2 I I I? _ co _._ co O � m O co 0 > _°N00 � LP • O Cl) O 00 1_ ;o O O F OD O ,f �+ m "t tc' IL Q OD > _ . __._... f- t r aa 00 M N O � 4anl.« � � o Cl) U _a 0 N �3 _3 ■�■L+�rw��w�■ Illwrs�www ■ ■��7r GV ■ ■ V ■� RGbV RV INSPECTION LINE: (303) 234 -5933 Occupancy Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day.: Plumbing INSPECTOR MUST SIGN M SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR - INITIALS COMMENTS: Footings /Caissons: Building jFinal Stemwall / (CEG) Concrete Encased Ground Fire Department Reinforcing or Monolithic ROW &'.Drainage Weatherproof / French Drain INSPECTIONS FOR PLANNING & ZONING, .FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping Sewer Service Lines "NOTE: ALL ITEMS MUST BE COMPLETED. AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. !FINAL INSPECTION BY THE BUILDING DIVISION: DOES NOT CONSTITUTE A UTHORIZA TION OFA CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY.% Water Service Lines '. POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB: FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) ^ -DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED'. '. FINALS Electrical Plumbing Mechanical Roof Building jFinal Fire Department ROW &'.Drainage INSPECTIONS FOR PLANNING & ZONING, .FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping "NOTE: ALL ITEMS MUST BE COMPLETED. AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. !FINAL INSPECTION BY THE BUILDING DIVISION: DOES NOT CONSTITUTE A UTHORIZA TION OFA CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY.% Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. �0 v ;W . g� INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE 1 INSPECTOR ' INITIALS '.COMMENTS: Footings /Caissons: Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / Drain Sewer Service Lines Water Service Lines Electrical (Underground) I I I ;.. !.I. 30/ION SAL 3nOW31d ION 00 :aoloadsul i�77 (n, ,5; :eiea SS69-6£d - £0£ le uggoedsui -ej joi peo `epew ueeq eneq suogoeuoo uegM oN sa), :peiinbei uoijoadsul -ea (:�Vpmv awil :uoiloadsui Ao1 elgejiene auo ON ❑ �n q8 0 /_ p :aegwnN Puaaad c� r 86 /sar7 oo :ssaippV gof dp :adA1 uoi;oodsul 33110N N01103dSNI Xef 6e68 - L£d (£0£) • eo!//O 5580 -50 (£0£) eqi/ uoi;oedsul ££691 (£0£) !�! uolslnia uollaadsul 6uipiine 30018 1t/3HM 30 A110 0 Al 3011ON S/HI 3AOW31:f ION 00 :aojoedsul :ale(] EE691 le uogoedsu! - ej jo{ peo `epees ueeq eney suolheJJ00 ueyM oN seA :paambai uoaloodsul -aa ( v — 377 awil :uoiloedsui ao} ajgejiene auo ON ❑ _S O/ ~Q/ :aaquanN Uuaaad O :ssaippV qof -4 6v ly :odA.L uol}oodsul 30110N N01103dSNl ('f Xej 6069 -290 (coo) • ao!/!O 9982 -9$0 (COE) � o'� eqy ugi;oedsul S669110e (EOE) !J! �0 uolslAld uol;oodsul 6ulpling 30clid JLv3HM d0 A113 4, 30110N SIH13A0kV3bf ION 00 1 0 :aojoedsuj O> -OZ;_ :a1e(1 es65-6SZ-6oc le uggoedsu.i -ei jo/ peo epuw ueeq eneq suo!loeJJoo ueyM j , o sa), :paambaa uoijoedsul-aa V - D Fj,- T - awil :uoijoadsui aol apapine auo ON ❑ 17 1901-01 :aagwnN Iiuuad /0- e - ntl G tsp O OGO :sseippV qor ®off -7-Ix jry :edAj. uoiloodsul 30110N N01103dSNI xe-4 6069-Z0z (sos) • eo!llo 9380 -900 (sos) euii ugpoedsul ££6S-b£Z (£O£) uoisinia uoiloodsul Ouipp e 3!Dal i IV3HM 30 A113 o~Aa City of W heat f kAie Date: - COMMUNITY DEVELOPMENT Plan Building & Inspection Services Division Permit # 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Building, Permit Application P~o.~?e~y ASI'~~ess ~n ~ ~ ln~ • ~ ga`' Property Owner (please print): Phone: 3o3- 7 -c.('7S Mailing Address: (if different than property address) Address: S c~ Ya rn u S f. Ste, t c f€ f City, State, Zip: /GtU ~..c. a f- ~ GE ter r ~i0 ~ d ? ~ Contractor: !~"~mo. (^-e-c "6~(~y ~ ~ ~ I „c . Contractors City License O (s 6 a 6 Phone: -So 3- 6(b 6- 71 G Electrical: Plumbing: Mechanical: City License # City License # City License # bes'cr~l~tion~o# world (Ztt~.O tk e u, S R spk-L S S Contact Value: 1 ?U 7 fpa.e-a s t , .S V(~~/S Review Fee (due at time of submittal): Squares 1 BTU's Gallons _ Amps Sq Ft. $ OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed. by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that Ihave read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) ONTRACTO or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: Jd Vt'^ U)6✓py SIGNATURE: DATE: /a4/tO Bldg Valuation: I `I City of Wheat Pdge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Building, Permit Application Date: Plan # Permit # f v U D"~ Property Address 10 q--c) o r 3 g f~ Ate- Cou- * ~ k Property Owner (please print): { t c.c-o ?j) p Phone: 3v S Mailing Address: (if different than property address) Address: ?G- $-V Uatti eL S~ . S t d- 'o-- City, State, Zip: 610. 3 CDlltractOr: (.sc W~i.~ 4 r k S 1. c f ~G / Z~~ , 1 r1 C. Contractors City License t a ( C, Phone: u 3 Y 6 - $ (o Sub~C~ontracto Electrical: Plumbing: Mechanical: City License # City License # City License # Desertptton P works CZc r w01 t { ~ S (a a 5~ 1~~ S S Contract Value: U . ~'~S{-~.tt t--Lw Cts~Grer Sl..~~,t s V Review Fee (due at time of submittal): Squares -T- BTU's Gallons Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate. applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility. for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: (OWNER) &::NNTRRACTO (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) - PRINT NAME: J -0 ~ ` A n R r 1' ~r SIGNATURE: /At DATE: L( /3' Q It ~xiltE flFPARTMENF„ ❑ approved w/ cornn)ents~~O°d~sapproved , Llto review regmred ~ Bldg Valuation: roe 4e City of heat C~e - COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Building Permit Application Date: Plan # Permit # /01 C,1~01 Property Address:; 10-7-6 cD Sg f' - a a ` 1 Property Owner (please print): rrc.,3 Phone: _?U Mailing Address: (if different than property address) Address: 3 C. Var, to S~ . Stile kL Eg_ City, State, Zip: wl I it /,.n Sam/) h k ~ Ooiitractor: Contractors Mechanical: City License # Plumbing: City License # City License # bescrtpxlonrof work: Con act Value: $ C 6- Review. Fee (due at time of submittal): Squares T_ ~ BTU's Gallons _ Amps Sq Ft. 1 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for. work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE (OWNER) ([CONTRACTORI~or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: SIGNATURE: J L. ^r^ ~ T DATE: ~r l a I((,, Bldg Valuation: CERTIFICATE OF OCCUPANCY CITY OF WHEAT RIDGE Issued Without Fee 7500 W. 29th Avenue Date December 6, 1995 Wheat Ridge, Colorado 80034 This certificate verifies that the building constructed and/or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code, Zoning and other related land use and development laws of the City of Wheat Ridge, and may be occupied forthe use specified. OWNER Louis Ficco ADDRESS 3650 Vance Street, #1 Wheat Ridge, CO 80033 CONTRACTOR F1000 Bros. m a ~ = N LA, PROPERTYADDRESS 10700 W. 38th Avenue W LEGAL DESCRIPTION: FOR THE FOLLOWING PURPOSE 30 unitgarage ~w No change shall be made in the use of this building without prior notice and a new Certificate of Occupancy from the City of Wheat Ridge./,I Chief Building Inspector Zoning W.A.Formes For Mayor ~ . n~_I: INSPECTIONS WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE BUILDING SITE 24 HOURS NOTICE REQUIRED FOR INSPECTIONS WHEAT RIDGE, COLORADO 7500 WEST 29th AVENUE (303) 234-5933 INSPECTION RECORD (303) 234.5933 JOBADDRESS 10700 W. 38th Avenue BUILDING PERMIT NO. 95-2175 DATE ISSUED 11 OWNER Louis Ficco CONTRACTOR Ficco Bros. SETBACKS FROM PROPERTY LINES: NORTH SOUTH EAST I TYPE OCCUPANCY West INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB I NSPECTION DATE INSPECTOR Foundations Footings Caissons Reinforcing or Monolithic Weatherproofing POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED Concrete Slab Floor: Electrical Ground Work Plumbing Ground Work Heating Ground Work DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED Rough Electrical Rough Plumbing Air Test Gas Piping Rough Heating & Ventilation (above must be signed prior to framing inspection) 'li Framin Insulation Drywall nailing Roofing Refrigeration Electrical underground Final Electrical Fixtures Plumbing Fixtures Heating & Ventilation Landscape & Parkin R.O.W. & Drainage Fire Department Job Completed OCCUPANCY NOT PERMITTEID UNTIL CERTIFICATE OF OCCUPAPq" f IS ISSUED PROTECT THIS CARL '40M THE WEATHER DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 95-2175 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date :11/2/95 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : FICCO LOUIS J Property Address : 10700 38TH AV Phone : 421-1961 Contractor License No. : 17598 Company : Ficco Brothers Phone : 421 1961 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $75,000.00 I hereby certify that the setback distances proposed by this permit application are accurate, PEftl'tlt F2B : $527.00 and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations Plan Review Fee : $0.00 made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Use Tax : $1,125.00 Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE ~P Total: $1,652.00 Description : REBUILD 30 UNIT GARAGE (1) This permit was issuetl in accordance with the provisions set forth in yopur application antl is subject to the laws of ihe State of Colorado and to the Zoning Re9ulations and Building Cotle of Wheat Ridge, Coloretlo or any other applicable ordinances of the City. (2) This permi[ shall expire if (A) ihe work authorized is no[ commenced within sixFj (60) tlays from issue date or (B) the 6uilding authorized is suspentled or abandoned for a period of 720 days. (3) IF ihis permit expires, a new permit may be acquiretl for a fee of one-half ihe amounf normally requiretl, ~rovitled no changes have been or will be matle in the original plans antl speafcations and any suspension or abandonment has not exceeded one (1) year. Fchanges are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done thatwill change the natural flow ofwater causing a tlrainage problem. (5) ConUactor shall notiry the Building Inspector lwenty-four (24) hours in advance for all inspections antl shall receive written approval on inspection carU before proceetliin withsuccessivephasesofthe'ob. (6) The issu of a ermit or the pproval o~drawings antl specifications shall not be construed to be a permi[ for, nor an approval of, any violation of the provisions of ihe bu' di g co es or any t oMinance, law, rule or regWation. . ~ Chief B ilding Inspector For Mayor THI PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date : Property Owner Property Address Contractor License No. Company F%C ( 0-- l-0 t/ , Tcj )1J / 0 7 U U OWNER/CONTR,4CTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of rewrd: that all measurements shown. and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C J and all other applicable Wheat RidgeArdinances, for work under this pertnit. (OWNER)(CONTRACTOR) Description : ~_V" 30 v ,Y.J Phone : `-1;-1- / q 6 / Phone: y,(/-/ j~/ ConstructionValue: Permit Fee : Use Tax : Total : BUILDING DEPARTMENT USE ONLY Approval : Occupancy : Walls Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company : Expiration Date : Approval : _J Pffins Re`qulr~7 Company: Expiration Date : Approval : ~ PtBns Required Company : Expiration Date : Approval : A (1) This permM1 was issued in accortlance with ihe pmvisions set torth in yopur applica6on and is sub]ect to the laws of the State of Coloredo and to ihe Zoning Regulations and Building Cotle of VMeat Ritlge, Coloretlo or any other applicable ortlinances of the Ciry. (2) This permit shall expire if (A) the work authonzed is no[ commencetl within sixry (60) tlays from issue tlate or (B) lhe builtling authonzed is suspentled or a6antlonetl for a penod of 120 Eays. (3) It this permit expires, a new permit may be acquiretl for a fee of one-half ihe amount normalry required, provltleA no changes have been orwili be matle in the onginal plans and specifications and any suspension or abantlonment has not exceetletl one (t) year. If changes are matle or it suspension or abandonment exceeds one (1) yeaG full fees shall be paitl for a new permiL (4) Nn work of any manner shall be done that will change the natural tiow of water causing a tlramage prohlem. (5) Contractor shall notiy the 8uiltling Inspector Rveny-four (24) hours in atlvance Por ali inspecnons and shall receive written approval on inspeIXion cartl before . proceetliing ith successive phases of the job. (6) The issuaof a p 'mit or Ihe approval ot tlrawings and speci6cations shail not be construetl ro be a permit for, nor an appmval of. any violation of the provisions of the buil g cotl or any o~tlinance, iaw, rule or regulation. Chie B dding Inspector For Mayor HIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION • DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : 95-2077 Date :10/18/95 Property Owner : FICCO LOUIS J Property Address : 10700 38TH AV Contractor License No. : 17598 Company : Ficco Brothers Phone : Phone : 421 1961 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certity that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR)SIGNED DATE Description : DEMOLITION OF FIRE DAMAGED GARAGES Construction Value : $500.00 Permit Fee : $10.00 Plan Review Fee : $0.00 Use Tax : $0.00 Total: $10.00 Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approvai: ffmmsfAm, e MLIMM (1) This permilwas issuetl in accordance wi[h [he provisions set forth in yopur application antl is subject to the laws of the State of Coloretlo antl to the Zoning Regulations and Buildiny Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This pemit shall expire if (A) the work authorized is not commenced within sixty (60) days trom issue date or (B) }he builtling authorized is suspended or abandonetl for a penod of 720 days. (3) If this permil expires, a new pemit may be acquiretl for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifcations antl any suspension orabantlonment has not exceeded one (t) year. IFChanges are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new pertnit. (4) No work of any manner shall be done thatwill chan9e the nalural flow of water causing a tlreinage problem. (5) Contractor shall notify the Building Inspectorhventy-four (24) hours in advance for all inspections antl shall receive written approval on inspection card before proceetliingwithsuccessive phases of the job. (6) The issuance of a pemit or the approval of drewings and specifications shall not be construed to be a pemit for, nor an approval of, any violaiion of the provisions of tf e buildin9 cotles or any other ordinance, law, rule or regulalion. b ( ~ yl"lfef Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 2345933 24 HOURS PRIOR TO INSPECTION