Loading...
HomeMy WebLinkAbout10875 W. 38th Avenuei CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: f n S W T D AVL Permit Number: on O 7 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes to When corrections h ve been made, call for re -inspection at 303-234-5933 11 ' Date: % � Inspector: DO NOT REMOVE THIS NOTICE R Da I-_._ 1 I CITY OFWHEAT RID Building In s GE (303) 234-59 3 tion Division (303) 235-2855 Office e (3o ction line 237-8929 Fax INSPECTION i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M% Job Address: 75 Permit Number: �/70 �9 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes( No) k _,' "When corrections have been made, cai%fdr re -inspection at 303-234-5933 Date: �' . 1—Inspector:-(-��� L DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201703719 PERMIT NO: 201703719 ISSUED: 07/11/2017 JOB ADDRESS: 10875 W 38th AVE EXPIRES: 07/11/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration Series Designer Color asphalt shingles - 21 sq. *** CONTACTS *** OWNER (720)202-7314 KIRBY JAMES SUB (303)254-4303 Michael Lallier 018641 Lallier Construction *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE; UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,397.00 FEES Total Valuation 0.00 �^ Use Tax 113.34 Permit Fee 140.90 ** TOTAL ** 254.24 ** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6.nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed. by City of Wheat Ridge. If report is not available the final. inspection will not be completed. INSPECTION RECORD °ccuanc'YType INSPECTION ONLINE FORM: http-//www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector CommentsInitials Pier Concrete Encased Ground (CEG) Gar rnrlo+inn / P F I attar Do Not Pour Concrete Prior 10 Approvai UT i ne Hpvve insPecuuIra Under round/Slab Inspections 9 p Date Inspector Comments Initials Electrical Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Sewer Service Plumbing Do Not Cover Under round or Below/In-Slab Work Prior 10 Approval UT i ne Hvvve insPecucnia Inspector Comments Rough Inspections Date Initials. *VW Sheathing � ♦ ✓ Mid -Roof !� Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drvwall Screw/ Nail Final Inspections Date Inspector CommentsInitials Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW &Drainage/ Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof 'I Zit v- Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits - rlease oe sure rear luuyli 1IIJL/Cl 11V110 01 U�� rr�r�«u rr�r,r • - - - -- -- - by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Roofing PERMIT - 201703719 PERMIT NO: 201703719 ISSUED: 07/11/2017 JOB ADDRESS: 10875 W 38th AVE EXPIRES: 07/11/2018 JOB DESCRIPTION: REVISION Adding decking to existing permit 9.61 squares. Residential Re -roof to install Owens Corning Duration Series Designer Color asphalt shingles - 21 sq. *** CONTACTS *** OWNER (720)202-7314 KIRBY JAMES SUB (303)254-4303 Michael Lallier 018641 Lallier Construction *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,297.00 FEES Total Valuation 0.00 Use Tax 132.24 Permit Fee 156.75 ** TOTAL ** 288.99 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201703719 PERMIT NO: 201703719 ISSUED: 07/11/2017 JOB ADDRESS: 10875 W 38th AVE EXPIRES: 07/11/2018 JOB DESCRIPTION: REVISION Adding decking to existing permit 9.61 squares. Residential Re -roof to install Owens Corning Duration Series Designer Color asphalt shingles - 21 sq. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of t roperty and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest hat I am legally authorized to include all en�and/or d within this document as parties to the work to be performed and t at all r t be performed is disclosed in this documits' accompanying approved plans and specifications. 17j Signature o,'. RVbd N RACTOR (Circle one) Date 1, This per' ; City of Wheat midge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(q)_ci.wheatridge.co.us FOR OFFICE USE ONLY Date: - n03 -1(1i Add to Permit # -1 I Z j - CC ��j �; Z! > n Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Property Owner (please print): ``� Phone: Property Owner Email: Mailing Address: (if different than property address) Address: City, State, Zip: Submitting Company Contact Person: ,jLT ���'i�i`I � Phone: Contractor: 1 --ICU, -C TP-uG , -r-�C Contractors City License #: o � ow) Phone: 323-95+4-M3 Contractor E-mail Address: Z-�B'f Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour — 2 hour minimum). Description of revised/amended work: Sq. Ft./LF 2,6)0 Btu's Amps Squares Gallons Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) $ Wo , cc) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this kation. CIRCLE ONE: (OWNER) (CONTRACTOR) or UTHORI PRINT NAME: SIGNATURE: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer DEPARTMENT Y of (OWNER) (CONTRACTOR) DATE: �� ^ I OCCUPANCY CLASSIFICATION: PUBLIC WORKS COMMENTS: Reviewer: 1 PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required Building Division Valuation: $ CITY OF WHEAT RIDGE, Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M 11 f) _ Job Address: / b'' i s Vv 3 Q �' Permit Number: 10 1 '-) t -1 -7 9.. -/0 A)e) C P tl ❑ No one available for inspection: Time AM/PM Re -Inspection required Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: O �' �� Inspector: DO NOT REMOVE THIS NOTICE R Da I-_._ 1 I CITY OFWHEAT RID Building In s GE (303) 234-59 3 tion Division (303) 235-2855 Office e (3o ction line 237-8929 Fax INSPECTION i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M% Job Address: 75 Permit Number: �/70 �9 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes( No) k _,' "When corrections have been made, cai%fdr re -inspection at 303-234-5933 Date: �' . 1—Inspector:-(-��� L DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: f n S W T D AVL Permit Number: on O 7 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes to When corrections h ve been made, call for re -inspection at 303-234-5933 11 ' Date: % � Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Tsn�7 ttj A V67 Permit Number: zo, '� C) 3-)l ❑ No one available for inspection: Time AM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: � o1 Inspector: DO NOT REMOVE THIS NOTICE *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201703719 PERMIT NO: 201703719 ISSUED: 07/11/2017 JOB ADDRESS: 10875 W 38th AVE EXPIRES: 07/11/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration Series Designer Color asphalt shingles - 21 sq. *** CONTACTS *** OWNER (720)202-7314 KIRBY JAMES SUB (303)254-4303 Michael Lallier 018641 Lallier Construction *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,397.00 FEES Total Valuation 0.00 Use Tax 113.34 Permit Fee 140.90 — — ** TOTAL ** 254.24 - - - - - *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201703719 PERMIT NO: 201703719 ISSUED:, 07/11/2017 JOB ADDRESS: 10875 W 38th AVE EXPIRES: 07/11/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration Series Designer Color asphalt shingles - 21 sq. 1, b my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest hat I am legally authorized to include all entities named within this document as parties to the work to be performed and th t all w' rk be - armed is disclosed in this document and/or its' accompanying approved plans and specifications. T- Al f- /I Signature cf O ons 1T -'ACTOR (Circle one) Date 1. This perm, w iss rid on the information provided in the permit application and accompanying plans and specifications and is subject to theimp 'ance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit h Il e- ire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing, and received prioYto the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3, If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of an manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The !issuance -or -granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable diode o' any ordmat�c� r regulatio jof this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett 2-0 I -7 0 S M From: no-reply@ci.wheatridge.co.us Sent: Wednesday, June 28, 2017 12:49 PM To: Permits CommDev_ Subject: Online Form Submittal: Residential Roofing Permit Application _ Categories: Dane Q Residential Roofing Permit Application t1 s This application is exclusively for new permits for residential roofs and for licensed, contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE cam, AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if \ your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address 10875 W. 38th Avenue James Kirby 720-202-7314 Field not completed. A -Is I, -L� Do you have a signed Yes contract to reroof this property? 21.0 It will need to be provided at the time of No permit pick-up. CONTRACTOR INFORMATION Contractor Name Lallier Construction, Inc Contractor's License 018641 Number (for the City of TOTAL SQUARES of all Wheat Ridge) roofing material for this Contractor Phone 720-434-0471 Number Provide additional detail Contractor Email Address jquimby@lcidenver.com Retype Contractor Email jquimby@lcidenver.com Address DESCRIPTION OF WORK Are you re -decking the No roof? Description of Roofing Owens Corning Duration Series Designer Color Shingle Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 21.0 material selected above? Does any portion of the No property include a flat roof? If yes, how many squares Field not completed. on the flat roof? TOTAL SQUARES of all 21 roofing material for this project Provide additional detail Re -roof the house and garage, roof pitch 4;12 here on the description of z work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract value or cost of ALL materials and labor) ��-q7 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Jeff Quimby for Lallier Construction Email not displaying correctly? View it in your browser. 3 5685 Gray Street Arvada, CO 80002 Telephone: (303) 254-4303 Fax: (303)733-2505 L[=h LALLIER CONSTRUCTION, INC. Lallier Construction, Inc. AGREEMENT �1 Name:y Date: Address: City/State: Wrf �= , �(�. Zip; - E -Mail: Home Phone: Wo C hone: Referr� ,�I�,�I-7�%�j1� Consultant: \z —C S- ��Lll�y Phone: 7�. �('C/`�' I Storm Date: l/ THE CONSUMER PROTECTION/ROOFING BILL DOES NOT ALLOW A ROOFING COMPANY TO WAIVE, PAY OR REBATE ANY INSURANCE DEDUCTIBLE Approximate/Scope of Services/ Materials & Cost Based on Current Known Damage Report Meet with insurance adjustor for inspections (when possible) and negotiate cost factors with insurance for supplements 5L4-1 Customer acknowledges receipt of Liability and Workers Compensation Insurance and Construction Preparation document Remove I Layers Comp Shingles Remove Layers Shake Shingle Remove Other Manufacturer LS 6t - Nameyt Color NE9i--QA\JcSquares2 > L years (Guarantee against leaks) Shingle Manufacturer Warranty Labor Warranty � j If Starter=lf Hip and Ride �Ib Felt/Synthetic Ice and Water Shield - Eaves/Vali All . 11CR&R Pipe JacksJL—R&R Attic Vents: Turbi urt /Ridge/Other Paint roof stacks tojchshingles f' If Rake Metal and If Eave Metal in Color If R&R Step Flashing sA — R&R Skylight D&R Swamp Cooler D&R Satellite Dish _-&R C im-pelai - Lg/+Mi e^d Sm sq R&R Rolled Roofing — sq R&R Mod Bit — sq Replace Decking (7/16 in. OSB) (j Roof Pitch: 7/12-9/12,10/12-12/ v r 12/12 Steep Sq.A� High Sq. Access: Y/N I Ger/ c Cr Remove and Replace If Gutters and If Downspou� in Cofor c' Windows Y/N Siding Y/N Y/N (See addendum for details) `Pta�int . (� p n., Damage Assessment: L-f►'L-� �C%�4JITt4[..17 j mkns o i�y (k-j(nf� /) e-Lt,1rJi�-K�a�..P�L -6 ena e -t * -h All insurance proceeds AND supplements (RCV) plus deductible payable as follows: p_ faD�iG APPROXIMATE COST $ L .. (PLUS PERMIT, S, A dt 4 APPROXIMATE DATE OF SERVICE% LALLIER CONSTRUCTION, INC. LIMITED 5 YEAR WARRANTY GENERAL CONTRACTOR. Homeowner acknowledges LALLIER CONSTRUCTION, INC. as a general contractor and as such shall be entitled to overhead and profit, as allowed by insurance industry standards. This only applies if the insurance company allows for overhead and profit. TERMS: By signing this Agreement, you, the homeowner, authorize LALLIER CONSTRUCTION, INC. ("Contractor") to act on your behalf and pursue your best interests with your insurance company in determining an appropriate roof and/or siding replacement or repair at a "price agreeable" to both the insurance company and Contractor with no additional costs to you except for your insurance deductible. When the "price agreeable" is determined it shall become the basis of the final contract price which consists of INSURANCE PROCEEDS and INSURANCE DEDUCTIBL e "Final Contract Price"). Customer authorizes Contractor to obtain labor and materials in accordance with the Final Co r t Price and the specifications set out herein and on the reverse side hereof and to accomplish such replacement or repair 5 Accepted by (Homeowner): el -5 l/L,,l �� Date: 5' /11 (Print Full Name) (Signature) Insurance Representative Agreement: It is understood that Lallier Construction, Inc. will be contacting my insurance representative and or meeting on my property to determine scope of loss (property damage) and compensation for loss (amount to be repaired) Insurance Company Claim# r G'w . Property Owner Signature: �� Date ♦ i CITY OF WHEAT RIDGE f Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax L INSPECTION NOTICE Inspection Type: Job Address: /08 -m l Ale- Permit Number: Of27b8° No one available for inspection: Time 12:' AM �PM r Re- Inspection required: Yes CN "When corrections have been made, call for re- inspection at 303- 234 -5933 Date: JZ- tS - -y9 Inspector: DO NOT REMOVE THIS NOTICE ♦ 1~ A i CITY OF WHEAT RIDGE Building Inspection Division 61101 X 10 0 I (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Pod F Job Address: 1075 (J 3'~3 T l+ AV Permit Number: =1 4p- 11 No one available for inspection: Time AM/PM Re-Inspection required: Yes No *When correctionshave been made, calgre-' SP tion at 303-234-5933 Date: Inspector: 17 DO NOT REMOVE THIS NOTICE — nortnwest roo ooz /ooz INSPECTION . RECORD ODCDDanDV/TyDe INSPECTION LINE: (303) 234 - 5933. Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS .JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons RECEIPT `NO- CDA062633'" AMOUNT BPSP,T /D:_ Install .18.28 s Stemwall / (CEG) Concrete Encased Ground 092768 - - - Reinforcing or Monolithic POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED ROUGHS .- - - Sheathing Weatherproof/ French Drain PBYMENT RECEIVED Lath /Wall tie Sewer Service Lines Mid -Roof Water Service Lines Auth Code:, , -: Electrical Service 1.1 a IN1 0 NXK.I: M -1 i"I1Ji 11 W-11 =7.P iF.R :I]y:l:Ird"T4i CONCRETE SLAB FLOOR Electrical (Underground) 09128L09._. 11:49 AM....., edha - - Thomas R Brown Plumbing (Underground) RECEIPT `NO- CDA062633'" AMOUNT BPSP,T /D:_ Install .18.28 s Heating (Underground) 092768 - - - Do NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED ROUGHS .- - - Sheathing Building Final PBYMENT RECEIVED Lath /Wall tie Fire Department Mid -Roof R•O•W & Drainage Auth Code:, , -: Electrical Service Parking & Landscaping TOTAL ' 263.91 * *NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND Z<, CERTIFICATE OFOCCUPANCY ISISSUED. FINAL INSPECTION BY THE BUILDING[ . OF A CERTIFICATE OF OCCUPANCY NOR PERMISSIO Rough Plumbing Gas Piping Rough Mechanical Screw FINALS . Electrical 09128L09._. 11:49 AM....., edha - - Thomas R Brown Plumbing RECEIPT `NO- CDA062633'" AMOUNT BPSP,T /D:_ Install .18.28 s Mechanical 092768 - - - Roof IZ- 15 "°?fi rUse Fax Building Final PBYMENT RECEIVED AMOUNT Fire Department R•O•W & Drainage Auth Code:, , -: INSPECTIONS FOR SHOULD BE CALU Parking & Landscaping TOTAL ' 263.91 * *NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND Z<, CERTIFICATE OFOCCUPANCY ISISSUED. FINAL INSPECTION BY THE BUILDING[ . OF A CERTIFICATE OF OCCUPANCY NOR PERMISSIO "CITY OF WHEAT RIDGE 09128L09._. 11:49 AM....., edha - - Thomas R Brown RECEIPT `NO- CDA062633'" AMOUNT BPSP,T /D:_ Install .18.28 s 263.91 092768 ­Permit Fee - -___ _ 162.90 rUse Fax lar 01 PBYMENT RECEIVED AMOUNT Auth Code:, , -: 072369 TOTAL ' 263.91 ♦ i CITY OF WHEAT RIDGE Bung Inspection Division m (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: 9,4,/ti.lPAi Job Address: 16127"1 td t Permit Number: 09271 'g ❑ No one available for inspection: Time T70, A P Re-Inspection required: Yes 'When corrections have been made, calf for re-Inspection at 3_03-234-5933 Date: Inspector: Wir I LL_ DO NOT REMOVE THIS NOTICE INSPECTION RECORD OccuDancvfy.Re 'Z'-INSPECTION LINE: (303) 234-5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings/Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) ROUGHS Sheathing Lath /Wall tie Mid-Roof Electrical Service Rough Flertric Rough Plumbing Gas Piping Rough Mechanical Framing Insulation Drywall Screw IE UN IIL AHVVE MA5 GEEN SIGNED TO BE SIGNED PRIOR FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR Parking& Landscaping SHOULD BE CALLS "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND Zf - CERTIFICATE OF OCCUPANCY IS ISSUED, FINAL INSPECTION BY THE BUILDING L OF A CERTIFICATE OF OCCUPANCY NOR PERMISSIC CITY OF WHEAT RIDGE 09/28/09 _ 11:49 AN cdba Thomas R Dromn RECEIPT NOCDA002633 AMOUNT _DPSP T/on_Install _18.28 s 263.91 092768 Permit Fee 162.90 Use Tax 101:01 PAYMENT RECEIVED AMOUNT MC 4868 263:91 Ruth Code: 07236D TOTAL 263 91 OCCUPANCY NOT PERMITTED UNTIL CERTIFICAI " PROTECT THIS CARD FROM THE WEATHER t-1I l&S City of ~ ~/G3/T T Y7 Dare: Permit Office: 303-235-2855 " Fax: 303-237-8929 Inspection Une: 303-234-5933 WAMANWAM Property owner (plea Wailing Address: (If different than property address) Address: C=Wm N ommo: Ate D4 vves-r ROOFINIz Contractor License Phone: :joB eo4 o3 o3 My - i IMn We Llcense #I: Exoiration Date: Trade/Profession: Approval: Use of s ace esorl Non : r4- ro o F -Fear aFF6t (i ayers, nstructlon Vah re-pl &ce- VV14 A O h e I Q I e r- 6A-F/E f1G 3 d~ plan Review (due at Nme at submiRalJ: S Sq. FUL.Ft added: Squares 8TWa Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT ' I hereby certlry that lho setback dlatanca!d roposed by Fhls pamtd apptloation are accurate, and do not vielale applicable ordinances rules or regulatlona of the Clly of Wheat ge or covenants, easements ar reshlctlona of record; that all measurements shown, and Pllegations made are accurate: that I ye eed and a®reo Ee abide by all conditions pdnted on this appllcation and that I assume full too onsibilgy for compllanra with the Whl Ridpo Sullding Code (I,E C) and all other applicable meat Ridge Ordinances, for worts under this permit. Plans subject to field inspection. ClRLcE O/vE:: (OWNER) (CONTR IArCoT.O_R} or PPERSONAI RM El SIGNATURE: PRINT NAME: r- alp, ~JVI'tK~Y id! Date: S! o-7 Bldg Valuation: $ I Credit Card Payment: Use credit card listed on files k7 tom; , Print name: _TO g)90W Signature: 5/5 0000000000 5ui4ooj aSarnyjjou Wd OGZI 9Z-d8S-600Z Facsimile Building Permit Application COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 17448 BUILDING INSPECTION LINE -(303-234-5933) Date : 7/29/2004 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) PropertyOwner: JamesWall Property Address : 10875 West 38th Avenue Phone : 641-3301 Contractor License No. : 19402 Company : Aaark Heating & Air Conditioning Phone : 431 8015 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the CiTy of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED ~2t'~ "W.~./~•---. - DATE 7/14 Description : 220 volt hook up to a/c am BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : onfngt~CQmm.ents: Approval : Zoning : C~Qffln~' Approval : ~u or s;Co men.5• Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval : Plumbing License No; Company : Expiration Date : Approval : Construction Value : $250.00 Permit Fee : $30.55 Plan Review Fee : $0.00 Use Tax : $3.00 Total: $33.55 Use: Mechanical License No : Company: Expiration Date : Approval : (7) This permit was issued in accordance with the provisions set forth in yopur application and is subjed to the laws of the State of Colorado and to the Zoning Regulalions and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. - (2) This pertnit shall expire if (A) the work authorizetl is not commenced within siuty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 720 days. (3) If this permit expires, a new permit may be arquired for a fee of one-half the amount nortnalry required, provided no changes have been orwill be made in the onginal plans and specifcations and any suspension or abandonment has not exceetled one (1) year. If changes are made or if suspension or abandonment exceeds one (7 ) year, full fees shall be paid for a new pertnit . (4) No work of any mannershall be d ihat will c natural Flow of water causing a drainage problem. (5) Contrector shall notifythe nsp ~enty-four (24 re in advance for all inspections antl shall receive written appmval on inspection card before proceediing with su si ase. e ~o (6) The issuance of a~ ~ v r ~ specifications shall not be consirued to be a permit for, nor an approval of, any viotation of the provisions of the b ilding co or any~~ riC$; law, rule or regulation. Chief Building Inspector Please sign Terms and Conditions on reverse side of page. DEPAs ;7AAENT OF PLANNING AND DEVELOPMENT Building Permit Number : BuiLDING INSPECTION DIVISION -235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 _ Property Owner : QW ~frto p Property Address : ~~~i~S 1ti --)~,~b 0 ttK' Phone :~j~ Comractor License No. : EtEC', 5656 (0~) ( Cy0 Yn'e°h ) Company: ppqr~- _kea-l m ~~fC Phone: OWNER/COhTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT iI hareby certiry >c; the setback distances proposed by this partnit application ara accurate, . and do not violaLc applicable ordinances, rules or regulations of the City of Wheat Ridga or covenants, esse~ nants or restnctions of record; ffiat all measuraments shown, and allegations made are acc~. .:,that I have read and aqree to abide bV all conditlons printad on this ! application, an,; :Piat I assume full responsibiliry for compliance with the Wheat Ridge Building '---Qotle (U.B.C.j an6 all o[ner appliwbla Wheat Rid ordinan , for work under tnis partnit. 'I (OWNER)(CONiFaCTOR)SIGNED - DATE / LLl&~l Construction Value : Msd Permit Fee : '~0,55 Use Tax : 3''O I Total : ~33 5' I j Descriptior:: V0i-"Vo=ek_vrf`c 416 (0-efical Q'ot BUILDING DEPARTMENT USE ONL' ~ rroval : Zoning : P.p,jroval : WIML ~~Gdt~...aW.Y111~'-~#d Approval : Occuparr,:y Walis : Roof : Stories : Residential Units : ElecVical Lice::se No : Plumbing License No : Mechanical License No : Company: Company: Company: ExpiCaUonL_'-a,e: FacpirakiorLDate: _ ExpiretionDate: - Approvai : Approval : Approval : (1) Thu perrni, vas issued in a«ordance with the provisions sat foM In Yopur applM.atlon and b wb ect to Ne kwa of the Stale of Colaatlo and w the Zoninp Repulaucns antl euiltling Code of NTeat Ridqe, Colorado or any other applicehle oMinancet of Clty . . (2) Th is perrn~~. snall wcpire d(A) the work auNOnzed le not commeneed wiNm sucty (80) days from iuue data w(B) the builtlinp aNhorizetl is suspentled or abandcr,,:'. tor a panod of 120 days. (3) If tnis p:, . ,iI expires, a new pemut may be acquired lor a(ee of ona-helf the amount nortnalty requireE, provitled no chanpes have Eeen or will bo made in the onginal pa-e and apeaficatlons and any auspanaion or abantlonment hes nOt azceeded w~s (1) yeaL II chenpas are matle or H auapension or ebandonmant g~ccee6;; (1) yeat, lull fees shall be paitl for a new permiG (1) Mo vrorv <.; _ny manner shall De Oone Nat will chanqe the naNral flow ol watar causin9 a drelnape problem. (5) Contrzci.: r;all notity the BuilOinp Inspector twenry-four (24) houo In advance lor all Inspecliont entl shall recaiva wntten approval on inspecUOn wrtl Ce(are procee~,-:,,aith sueeessive phases oltheI'ob. (B) The iss:::.: of a permit or tne appmval o( dmwinqs and spacificatlons shall not he wnaWatl to be a parmit for, nor an aDProval of, any violaGOn of Na provisions 01 NB bci.f.:ny WdeS Of any oNOf OfdlnanCB, 12W, NIB 0!leyu13t100. . Chier Sui;ding Inspector For Mayor Teii's ;'ERMIT VALID ONLY WHEN SIGNED @Y THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOI;RS PRIOR TO INSPECTION COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number Date 17285 6/25/2004 Property Owner: JAMES S. WALL Property Address: 10875 W 38TH AVE Phone: 424-5565 Contractor License No. : Company : Phone : OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $1,300.00 I hereby certify that the setback distances proposed by this permit application are accurate, and Permit Fee : $62.31 do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easementsor restrictions of record; th t all measurements shown, and allegations Plan . Review Fee : $0.00 made are accurate; that I have read and e to ide byall conditions printed on this appliration, and that I assume full resp sibility r compliance with the Wheat Ridge Building Use Tax : $26.00 Code (U.B.C.) and all other applicabl hea idge ord' ancesif! o work u er this permit. . (OWNER)(CONTRACTOR)SIGNED . DATEolg^ Total : $$$.31 Use: 1-11 Description : 24'R6UND POOL 46" DEEP ABOVE GROUND POOL. NOT PERMINENT. Approval : TRC Zoning : R-1C F ~ lilp xrg~Commer~ts. Approval CR n•~,~ U ic=Wor ~Cpmmeml Approval : Occupancy: Electrical License No Company : Expiration Date : Approval: BUILDING DEPARTMENT USEC~~Y ~jney r~~ ~x Sq. Ft. : OK SheC~h~~dp~~i4LctinRr`5poh .~ck,. reSU t. the e po~ ef,eJ~1~' NO BUILDING ISSUES. 6I22/04 n6,~o~AI ~ccu~ ~~cozj trocfr` I(~yI ~ Walls : Roof Plumbing License No : Company : Expiration Date : Approval : Mechanical License No : Company : Expiration Date : Approval : (1) This pertnit was issued in accordance with the provisions set forth in }ropur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Coloredo or any other applicable ordinances of the Ciry. (2) This permit shall expire if (A) ihe work authorized is not commenced within siuty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 720 days. (3) If this pertnit expires, a new permit may be acquired for a fee of one-half the amount normaliy required, provided no changes have been or will be made in ihe . original plans and specifcations and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit (4) No work of any manner shall be done thai will change the natural fiow of water causing a drainage problem. . (5) Contrector shall notify the Building Inspeclor hvenry-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) Theyyyi~~~ssuance of a pertnit orthe approval of drewings and specifcations shall not 6e construed to be a permit for, nor an approval of, anyviotation of the prov' hebuildi oranyother ordinance, law, rule or regulation. ~ Chie Buildi ector Please sign Terms and Conditions on reverse side of page. Stories : Residential Units : COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: o~ W"E~T~, BUILDING INSPECTION LINE - 303-234-5933 Date: ~ , $ CITY OP WHEAT RIDGE ° 7500 WEST 29TH AVENUE W HEAT RIDGE, CO 80033 -(303-235-2855) `°`°R"°° APPLICATION Property Owner. ~;,ut5 5 L PropertyAddress: 1t7C675- cJ 39TL rA-JC- Phone: 30"3-yZLI -SSZ ~S- Convactor License No.: Company: & , / LPhone: (-~N'IGs QW OWNER/CONTRAC70R SIGNANRE OF UNDERSTANDING AND AGREEMENT I hereby certity that the setback distances proposed by this permit application are accurate, and do nol violate applicable ordinances, mles or regulations ot the City of W heat Ridge or wvenanfs, easemen[s or restnctions of recortl; that all measurements shown. and allegatlons made are accu2te; that I have read and agree to abide by all conditions printed on this appli ' and that I assume full responsibility tor comptiance with the Wheat Rid B ilding Code (U.B.C) antl all other applicable W heat Ridge Ordinances, for rk der this permiL Description: Py' /Lc9~viJ l~cx>~ ~CV' pl~ act~ . Sq.Ft.added Construction Value:$ Permit Fee:$ Plan Review FeeS Us Tax- Total:$ t i-/b" J~cp 416C,,~e- GZvr~oJ DEPARTMENT USE ONLY I a6~~ I ,t1OT COMMENTS:/~ ApprovaC t~/ Zoning: PtL ~ G COMMEN7S: . lb rJ T~, p Approval: ~G~Q~ . ~ WORKS COMMENTS: Approval: W alls: Etectrical License No: Company: Residential Units: Roof: Stories: Mechanical License No: Company: Plumbing License No: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This permit was issued in accordance witli the provisions set forth in your application and is subjecl to the laws of the State of Colo2do and to the Zoning Regulations and Building Codes ot Wheat Ridge, Colorado or anyother applicable ordinances of . the City. (2) This pertnii shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspentled or abandoned for a period of 120 days. (3) If this permit eupires, a new pertnit may be acquiretl for a fee of one-halt the amount normally required, provided no changes have been or will be made in the original plans and spedfiratons and any suspension or abandonment has not exceede0 one (1) year. if changes have been or ii suspension or abandonment exceeds one (1) year,lull fees shall be paid tor a new permit(4) No work of any manner shall be done Mat will change the naNral flow oi water causing a drainage problem. (5) ConVaclor shall notify the Building Inspec[or twenty-tour (24) hours in a0vance tor all inspecGons and shall receive wririen approval on inspecGOn wr0 before proceeding with successive phases of the job. (6) The issoance ot a permil or the approval of drawings and spedfica6ons shall not be construed to be a pertnit for, nor an approval of, any violaUOn of the provisions of the building codes or any other ordinance, law, rule or regulation. Chie ilding Official 7--1- Pz,o~ ~C) j oo i 0 5e, 1~6d~ ~ovl - ~oa ~ ; y ~ o E y~ ` i i ~ a S~ oNk STay r~rt 1 ! cJ,W ~ ~ -c- /OSFS !,J- 3ot" A-Je -5 _ . I . ~ I , ~ COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5935) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEATRIDGE, CO 80033 - (303-235-2855) Date 17050 5/7/2004 Property Owner: JAMES WALL Property Address : 10875 W 38TH AVE Contractor License No. : 19402 Phone : 641-3301 Company : Aaark Heating & Air Conditioning Phone : 431 8015 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of W heat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.CJ and all other applicable Wheat Ridge ordinances, forwork underthis permit. (OW NER)(CONTRACTOR) SIGNED DATE Use: Description : TO INSTALL A 200 AMP ELECTRICAL SERVICE CHANGE & MOVE BUILDING DEPARTMENT USE ONLY ~Loni~ag Comments:; SIC : Approval: Zoning : Building Permit Number Construction Value : $1,000.00 Permit Fee : $50.40 Plan Review Fee : $0.00 Use Tax : $12.00 Total: $62.40 s~ Comments~, AppYOVaI: i~~Vorks Comm ne tsc Approval: Occupancy : Walls : Roof Sq. Ft. : Stories : Residential Units : Electrical License No : Company: Expiration Date : Approval: Plumbing License No : Company : Expiration Date : Approval : Mechanical License No : Company: Expiration Date : Approval: (1) This permit was issued in accordance with the provisions set fodh in jropur application and is subjec[ to ihe laws of the State of Coloredo and to the Zoning Regulations and euilding Code of Wheat Ridge, Colorado or any oiher applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within siuty (60) days from issue date or (B) ihe building authorized is suspendetl or abandoned for a period of 120 days. (3)' If ihis permit expires, a new permit may he acquired for a fee of one-half ihe amount nortnally requiretl, provided no changes have been orwill be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit (4) No work of any manner shall be done thatwill change the natural flow of water rausing a drainage problem. , (5) Contrector shall notiry the euilding Inspeclor hventy-four (24) hours in advance for all inspections and shall receive written approval on inspeclion card before pmceediing with successive phases of thejob. (6) The issuance of a permit or the approval of drewings and specifirations shall not be construed to be a permit for, nor an approval of, any violation of fhe provisions of the ~g cod any o mance, law, rule or regulatioa 4 . C' f uil ' g Insp c o Please sign Terms and Conditions on reverse side of page. r ' I i DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE VVHEAT RIDGE, CO 80215 Building Permit Number : Date : Property Owner Property Address Contractor License No. Company jar~ ~J~~I ~ u1~. 38'' A'-e' Pnone : 6'~ I 3341 Pnone : 43i $46 ONMER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 'I hsnby certify that the setback distances proposad by this pertnit appllcatlon are accurats, and do not violate applicable ordinances; rulea or repulaGons of the City of Wheat RIdQs or ewrananb, easements or restrictions of rewrd; that all measuromenb shown, and ailepatlons - rtiads are accurate; that I have read and agree W abide:by all conditlons printed on this appIiCatlon, and that I assume PoII responsibtldy for comP6ance with the Wheat Ridye Building '-'-Cods-(U.6.C.jand all otner applicable 4Yheat Ridp ordman ,for work under thisV~y rtnit. ' (OWNER)(CONTRACTOR) SIGNED ~ / DATE SJ l~D,~ DescripGon :'`d f.✓~.yw 8W4-f-1-eer1 %NtC"1l (i1k BUILDING DEPARTMENT USE ONLY ~ Approval: Zoning : ' . Approval: . ~11~Y1(tJPlf~~!!}? _ hts'd Approval : ' Occupancy : Walis : Roof : Stories : Residential Units : Construction Vaiue : 41ppdco Permit Fee : J y0`40 UseTax: ~ 1~00 Total: y6Z.q0 < mPk wcacLGq "ElecVical License No : Plumbing License No : Mechanical License No : Company: Company: Company: F.jpiCaUon Date : , EXpiratio[LDate : Expiration Date : Approval : Approval : Approvai : (1) Thls permit waf laued in acoordanu with tM provWont wt torth In Yopur appllutlon antl 4 wbleU b the laws of the SU4 ot Cdaatlo and b the Zo(wq RYpWations an0 BuIlClnp Cods of Wh~at coar+do «ury onw spWkaw. orainanas a iM uh• . (2) This parmit shaU exPire d(A) tne wak ~ k not cwmrncW withln Wcqy (80) tlaYS Irom luw tlaW or (B) the buiWinp aWwdzeG 4 suapen7ad a abandone0 fw a period of 120 dayi. (3) If tNS permit expa naw pam¢ maY Ce+Wuiretl tw a fe~ of anslwH ths arnount nanWly reqWrW, provWW ro Gwnpos havs bean or wm be maEe in the orlpinal plans end $ peafitatlwu arM any swunsbn or aban0onment hu ml axaWad on~ (1) Y~. If dwrpa aro mede w H sutpauion w ebantlonment eztseda one (1) year, (ull fess shall be paid (or a new partniL Nb work ot any manner shaU Ds Cona that will U~anpe Na naWral Ilow ol waUr caualnp a tlnlnaps proW~m. (5) Convaaor snall noGh Ne euilairp InsGecta Iwanty-lour (21) Mun In ad~hvance foc all IntpWlons and shall recaWa written appioval on InapecUOn caN Cefore ts bb procsediing wiN eucces~ive phasa. o ih (9) Tne bsuance of a permit a tne approwl o(Nwinpe anE spaGfieaOOn, all not ba oansWeO b Da a parmit for. nor an approval of, any violaUon of tho provisbns of Ma Duildinp co0es or any othet or0inanca. law, rule w requlaUOn. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-6933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 14041 BUILDING INSPECTION LINE - 303-234=5933 Date : 6/17/02 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner: TERRY FELTIS Property Address : 10875 W 38TH AVE Phone : 421-7239 Contractor License No. : Company: Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $800.00 I hereby certify that the setback distances proposed by this permit application are accurate, and Pefmit Fee : $32.65 do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or Plan Review Fee : $0.00 covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this Use Tax : $16.00 application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.CJ and all other applicable Wheat Ridge ordinances, for w ork under this permit TOtBI : $48.85 ~ y ~ (OWNER)(CONTRACTOR) SIGNED i~ -~~~~s4~1lk»-DATE4~I USB: Description : REPLACE 2 WINDOWS IN LIVING ROOM, 1 SLIDER WINDOW IN BEDROOM 48" X 8' Approval: Occupancy : Walls : Roof : Electrical License No : Plumbing License No : Company : Company : Expiration Date : Expiration Date : Approvai: Approval: Stories : Residential Units : Mechanical License No : Company: Expiration Date : Approval : (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colo2do and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any oiherepplicable ordinances of the Ciry. . (2) This permit shall expire if (A) the work authorized is not commenced within sixly.(60) tlays from issue date or (6) the building authorized is suspended or abandoned for a periotl of 720 daya (3) If this permit expires, a new permit may be acquired for a fee of one-haif the amount nortnally required, provided no changes have been orwill be made in the original plans antl specifca[ions and any suspension or abandonment has not exceeded one (7) year. If changes are matle or if suspension or ahandonment exceeds one (1) year, full fees shall be paid for a new permit (4) No work of any manner shall be done that will change the naturel Flow of water causing a drainage problem. (5) Contrector sha0 notify the Building Inspedorhventy-four (24) hours in advance for all inspections and shall receive written approval on inspection card before pro iing with su ssive phases of the job. (6) ei4 i is n rmit or the approval ofdrawings and specifcations shallnot be construed to be a permit for, nor an approval of, any violation of the ovi nng 5o es or any other ortlinance, law, rule or regulation.. Chief Building Inspector o wryEqT DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number. ~ o BUILDING IN5PECTION LINE - 303-234-5933 Date: ~ m CITY OF WHEAT RIDGE 7500 WEST 29TH AVEN UE WHEAT RIDGE, CO 80215 - (303-235-2855) C~CORPDO ,yHH ~r p 4~S"i'U" d i O7~~ 4 Property Owner: 27G Pro eriY Address: /087~ ~ "9 c~ P Phone :~o.~~ Coniractor License No.: ~ yli~J Company: ~iU1/9 Phone: OWNER/COr'TRACTOR SIGNATURE OF UNDERSTANDING AND ACREEMENT a0 I hereby certify thatthe setback distances proposed by this pemtit application are accurate, l~Construction V2.IllE:$ 90t" anddonotviolateapplicableordinances,nilesorreguladonsoftheCity ofWheatRidgeor PermitFee:$ covenan4,easementsorresuiclion5ofrecord;fhatallmeasurementsshown,andallegations made are accurate; that I have read and agree to abide by aIl conditions printed on this Plan ReV1eW F'ee:$ application and that I assume full responsibility for compliance with the Whea[ Ridge Building Code (U.B.C) and alt other applicable Wheat Ridge O;dinances, for work under U se lax:$ Uiis permit. Total:$ (OWNER)(CONIRACTOR):SIGNED xDescription: ,~£~Gr?r~ ~ u.~<ti~' ~vs 1=~-rJ L<v<.z/b Rao.^-z b f BUILDING DEPARTMENT USE ONLY ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: ApProval: A (1; ~/~~/~z PUBLIC WORKS COMMENTS: Approval: Occupancy: Walis: Roo£ Electrical License No: Company: Stories: Residential Units: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: ApprovaL (1) This pemiit was issued in accordance vrith the provisions set forth in yotv application and is subject to the laws of fhe State of Colorado and to the Zoning Regulafions md Building Codes of Wheat Ridge, Colorado or auy other applicable ordinmces ofthe City. (2) Ilus petmit shall exp've if (A) the work auUiorized is not commenced within sixty (60) days &om issne date or (B) tlie building authorized is suspended or abandoned for a period of 120 days. (3) If this pemut erzpires, a new permit may be acquired for a fee of o¢e-half the amouut noimally reqnired, provided no dianees hzve been or will be made in theoriginal plans and.specificafions avd any suspension or abandonment has not exceeded one (1) year. ifchanees have been or if nispension nr ahandoninen! exceeds oue (1) yeaz, full fees shall be paid for a new permit (4) No work of any mamer shaR be done that will change Eae nanual flow of water causing a draivage pmblem. . (5)' ConhactorshallnofifyNeBuildingInapecrortwenty-foar(24)lioursinadvauceforallinspectionsandshallreceivewrittenapprovaloninspectloneardbefore proceeding with successive phases of die job. (6) The issuance of a permit or ihe approval of drawings and specificadons shall mt be construed to be a pelmit for, nor an approval of, any violatlon of Hie provisious of the building codes or auy other ordinance, law, rvle or regularion. Chief Building pector - Building Sketch _ Baqawer Client TERRY FELTIS & MICHEILE GER$I_ Pro Address. 10875 W. 38TH PLACE.__ C' WHEATRIDGE _ -County JEFFERSON State_CO. ZipCotle_80033 Lender LEAPFROG FINANCIAL 48.0' 24.0' Famii~oom fSc+~.~~ Gzr<'y.0~ 1~'~~r 4 Dining Kitchen Room I Bedroom 24.0' Living Room Bedroom S~ 43~ f i 48.0' G c) t.eJ,S ~Q ~ 41 , \c~ SKETCH CALCULATIONS A1 48.0 x 240 = 71520 at FifSI FIOOf 1152.0 ToWI Living Area 1152.0 DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 14058 BUILDING INSPECTION LINE - 303-234-5933 Date : 6/21/02 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner: TERRY FELTIS Property Address : 10875 W 38TH PL Phone : 421-7239 Contractor License No. : Company: Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application-are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C j and all other applicable Wheat Ridge ordinances, for work under this permit.. (OWNER)(CONTRACTOR) SIGNEDfz=kt;,~ DATE Description : COVERED PORCH/ DECK 8' X 16' Construction Value : $2,000.00 Permit Fee : $69.25 Plan Review Fee : $0.00 Use Tax : $40.00 Total: $109.25 Use: ~t ~`J Electrical License No : Company : Expiration Date : Approval: Plumbing License No : Company : Expiration Date : Approval: Mechanical License No : Company: Expiration Date : Approval: (1) This pertnitwas issued in accordance wiih ihe provisions set forth in yopur application antl is subjec[ to the laws of the S[ate of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ortlinances of the City. (2) This permit shall expire if (A) the work authorizetl is not commencetl wiihin sixty (60) days from issue date or (B) the building auihorized is suspentled or abandoned for a period of 120 days (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount nortnally required, providetl no changes have been or will 6e made in the original plans and specifcations and any suspension or abandonment has not ezceeded one (1) year. If changes are made or if suspension or abandonment exceetls one (7) year, full fees shall be paid for a new permit . (4) No work of any manner shall he done that will change the naturel flow of water causing a dreinage problem. (5) Contrecior shall notify ihe Building Inspectortwenry-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) The is e ce oflit or the approval of drawings and specifrations shall not be wnsiruetl to be a permit for, nor an approval of, any violation of the ro " mo g cotles or any other oNinance, law, rule or regulatioa . Chief Building spector _ DEPARTMENT OF PLANNING AND DEVELOPMENT Building Pennit Nuinber: OF WHE4T ; BUILDING INSPECTION LINE - 303-234-5933 Date: CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) C~CORA00 APi"HO"F ~d O~7~ 4 V . ProperryOwner: j<~~~~ ~Lc,: .~•5" . ProPertY Address: 1087,'7- W 3 8~` P~'~ C L Phone: 303 7°2`3 7 - Conuactor License No.: rrJ Company: ~tJ.$ Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby cer[ify thatthe setback distances proposed by this pemit application aze accurate, and do not violate applicable.ordinances, mles or regulations of the City of Wheat Ridge or covenants, easements orreshictions ofrecord; tfiat all measuremenu shown, and allegations made are accurate; that I have read and agree w abide by aIl conditions printed on this application and that I assume full responsibiliTy for compliance with the Wheat Ridx Building Code (U.B.C) and all other applicable Whea[ Ridge Ordinances, for work under this permiL (ovmim)(coxrxacrox): siGNEn 1~~ ~ars~ ~ i Description: ZONING COMMENTS: Approval: Zoning: /V() Construction Va1ue:$ 00 6a Permit Fee:$ :9-q- ~ Plan Review Fee:$ Use 'fax:$ `fCj. ~SO BUILDING DEPARTMENT USE ONLY BUILDING COMMENTS: Approval: 615uJIa'- PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This pemit was issued in accordance with the proviaous set foith in yonr applicatlon and is suhject to the taws of tlie State of Colorado and ro the Zoning Regdations and Building Codes of WLeat Ridgq Colomdo or aay oUier applicable ordinances of llie City. (2) lhis pemit shall exp¢e if (A) the work authorized is not commenced vrithin sixty (60) days from issue date or (B) tlie bnildiug anthonzed is snspenAed or abandoved for a peaod of 120 days. (3) If this pemit expires, a new pemit may be acquired for a fee of oue-haif the amoont nomaily reqiiired, provided no changes have been or will be mzde in the original plans avd specificaROns aud any snspension orabandonment 6as norezceeded oce (1) year. Ifclianges hzve been or if mspension nr abanAnnmem exceeds one (1) yeaz, full fees shall be paid for a new permit (4) No work of any manver shall he done that wilt chmmge the nanval flow of water cansing a drainage problem. (5) ContractorshallvoRfytheBnildinglnspectortwenty-four(24)hoursinadvance forallinspecfionsandshallreceivewrittenapprovaloninspectioncardbefore proceeding vritli successive phases of thejob. ' (6) 17ie issuance of a peimit oc ihe approval of drawings and specifications shall not be consnued to be a pemit foq mr an approval of, any viotztion of the provisions of the building codes or auy oWer ordinavce, law, rule or regulafion. ~ Building spec or SIC: Sq. Ft.: ' ,.;^w VI" 441" Stories: Residential Units: Total:$ CHqpT o~9o Building Guide Colorado Chapter of the International Conference of Building Officials 7953 At least three completed documents must be provided to apply for a building permit: 1 Complete this Buiiding Guide by filling in the blanks on page two, and indicating which construction details will be used. 2 PI'OVide 8 H001' Pl811(site plan) showing dimensions of your project or addition and its relationship to existing buildings or structures on the property and the distance to existing property lines. 3 Fill out a building permit application. The majority of permit applications are processed with little delay. The submitted documents will help determine if the project is in compliance with building safety codes, zoning ordinances and other applicable laws. The Colorado Chapter of the International Conference of Building Officials is a professional organization seeking to promote the public health, safety and welfaze relafive to building construction. We appreciate your feedback and suggestions. To obtain a master copy of this Building Guide, please write to Colorado Chapter of the Intemational Confeience of Building Officials, P.O. Box 961, Arvada, CO 80001. This handout was developed by the Colorado Chapter of the International Conference of Building Officials as a basic plan submittal under the 1994 Uniform Codes. It is not intended to cover all circumstances. Check with your Building Department for additional requirements. How to Use this Guide 6/97 2. Indicate in the check boxes which details from page 3 will be used. Please note if any of the sides of your carport addition are closer than 3'-0" to the property line, that side of the carport must be enclosed with a solid 1 hour fire rated wall as shown in Alternate Details B and C. You must however, keep at least two sides of the carport open to conform to the building code requirements. A zoning variance may be required. Roof covering 3 i.-;725' srr<--~1- - . (ezample: Class A 3 fab shingles) Underlayment 3aJ 14:L7-e_ T (crample: 2layers 15N felt) 12 pitch 2x-& rafters spacedjO.C. (example:2x e raRers spacetl24' O.C.) "x 6 "beam ~ Detail A ❑ Detail B ❑ Alternate A WAlternate B (see page 3) (see page 3) Existing building Maximum rise s" g ox3 ry at door I faNR ~ ~ ?u1~ ❑DetailC j ❑ Alternate C (seepage3) Slope Concrete Slab Minimum Diameter Pier S" This handout was developed by the Colorado Chapter of the Intemational Conference of Building Officials as a basic plan submittal under the 1994 Uniform Codes. It is not intended to cover all circumstances. Check with your Building Department for additional requirements. s1-Sn minimum : minimum ~ Span_,R-Lo " (example: 10'-3 ) Siding jj~i9 Z/ 11 XpOStS (example: 4W) spaced a~ ~ apart ~?l6 CPtic/1~:G Footing __"xL" (forNfemafeCOnly) 121 Directions 17 1. Fill in the blanks with dimensions and materials which ~ 36 c~ ~,~oG ~ will be used to build the structure. Please print legibly. y 7- I'g F/9 Existing roof rafters or trusses Galvanized metal joisi or rafter hangers ~ Extend undedayment from new roof a minimum of 18" onto existing roof Il Cont.2~c ledger Remove existing fascia Secure to wall with 41/2" x 3/8" bolts @ 16" O.C. Locate bolts to penetrate top plate or studs Existing wall Note: Remove brick veneer Or siding at iop of wall before installing coniinuous 2x ledger Solid 2x blocking Lap underlayment a minimum of 18" under existing roofing felts Solid 2x blocking Enisting wall 5/8" type "X" exterior gypsum sheathing ~ Existing Roof Cont. 2x6 secured to existing roof w/41/2"x3/8" lag bolts at each rafter or tmss Solid 2x blocking~ 2x cedar or redwood facia ~ y Exterior siding " Galvanized metal posVbeam exterior gypsum 5/8 board soffit connector Infill between posts w/ Galvanized metal . 2x4's @ 16" O.C. post/beam connector ~ Alternate D:tf. C - On: .our W. Bottom plate shall be treated Infill between posts Minimum 3 1/2" Galvanized Wood or Foundation redwood w/2x4's @ 16" O.C. concrete siab column base w/ 1" spacer to Minimum 3 1/2" _ ` concrete r: concrete siab ~V Galvanized column ~ base w/ 1" spacer ~ - to concrete ~ Tie slab to 8" minimum foundation w/ diameter 2'-0" x 2'-0" #4 concrete 3'-0" bentrebar caisson minimum Check local building 3'-0" I - departmant for ' rninimum swelling soils. ~ caissons may 81 be required. Footing This handout was developed by the Colorado Chapter of the Intemational Conference of Building Officials as a basic plan submiftal under the 1994 Uniform Codes. It is not intended to cover all circumstances. Check with your Building Department for additional requirements. 6/9] ~ Existing building ~ Nail to joists with galvanized d)screws ils ~ screw to joists with non-corrosiGalvanized metal joist hanger Lag bolted to existing bldg. with lag bolts ~art. Locate bolts to penetrate rim joist ag bolt railing to beam ~ Galvanized metal joist hanger Full depth 2x solid blocking 24" max. iag bolt railing to beam ' Galvanized metal posUbeam connector Lag bolt railing to beam I Galvanized metal I I J_ ` Galvanized metal I posUbeam connector posUbeam connector /z' Diameter anchorbolt embedded 7" min. into concrete pier orthe equivalent Galvaniied metal post anchor Finished rade ;.1. 6" min. If less than 6", post must be treated or redwood ; • ~ E ~ s ~ 8"(min:)'diameterpier 0 c co . . . . . This handout was developed by the Colorado Chapier of the International . Conference oF BuildingDfficials as a basic plan submittal under the ~ 7994 Uniform Codes. It is not Intended to cover all circumstances. ~ Check with your Building Department for additional requirements. Open guardrails and open handrails on decks and stairways more than 30 inches above grade or a floor below shall have pickets or intermediate rails spaced so that a 4 inch diameter sphere cannot pass through. Guardrail 36" min. height Stairway Notes: 1. Stairways shall be not less than 36 inches in width. 2. Stainvay rises shall be not less than 4 inches nor greater than 8 inches. 3. Stainvay treads shall have a minimum run of 9 inches. 4. The greatest riser height and largest tread run in a stairway shall not exceed the smallest by more than 3/8 inch. Handrail (see details below) Deck i Guardrail required if more than 30 inches 34-31 above 9 inch min. run _ Not less than Landing 4 inch min. - 8 inch max. rise iw th of stairway ~ ~ Finished grade Handrail Notes: 1. Handrails shall be continuous on at least one side of stairs with 4 or more risers. 2. Handrails shall be placed not less than 34 inches nor more than 38 inches above stair nosings. 3. The handgrip portion of handrails shall be not less than 1-1/4 inches nor more than 2 inches in dimension. 4. Handreils shall be placed not less than 1-1/2 inches from any wall or other surface. 1?/2 inches min. 1 '/a to 2 inches E::[ Wall or otMersuI-, 1-1/2 inches min. This handout was developed by the Coloredo Chapter of the Intemational Conference of-Building Officials as a basic plan submitlal under the 1994 Uniform Codes. It is not intended to cover all circumstances. Check with your Building Department for additional requirements. ~ ~ / : ,v T ~ ~ ~ ~ ~ w a a ~ ~ 3 v: ~ . ~ r~ ~ [f~ N on~ ~ i7nry H V ✓ C' ^ I ~ Y " r H c N ` s= r H -Um ( v u ~ i m ~ < u~ z 4I - Q ~a O ~ ~ ~ J tt ~ ~ S « J ~ n- ~ ~ o ~.1 M1 ry of ~ O 0 - om 3 Y a e ~I E° . ca . ~ 1~ - C ~ ~ lJ ~ H b i _Si. El L I h ~I,. ~ ' I F¢ I w V~~ ~ ~ o x a C~Q Q~ N~ iP y o i L. '~i_._ p•aZ __1 I~ c u ~ ,02~4tS o ~Ny waFQ 4C6 -x .y _ W ,7 ~ J Vl ~ Q L?a z_ , u o `v m « Q r ~ @ o E~ .ry V ~ - O ~ o W [ (5y r 'v' .1 a e °g ~ c 5 ~ ~ L n b i a E 9 ~ ~ ~ a ~ {s~ . 00 4- 9@s~ 9 << dbg° nB: ~:.s5F~~9 oy4~~yw qg~g.$o ~ g a ~ Il ~9 v ; ~y,~ ' .Y O ~ry 6Hn. At a. ~E$ ~9 e ~E Pa q.~.yp9 y~p9; ~Jy Ed 9 t~I t~~~h a6i~~8 1 ;i 1~~ G d; D E LL ~ z O 7