Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10901 W. 38th Avenue
I z 3 4 5 6 8 WEST METRO FIRE STATION GENERATORS West Metro Fire CO Lakewood, Colorado 4 q e c D E F H iy►, � Y! } � +l 11SN � � Y ' � �,� . _1•i - + r lam, a— fr A S 1 .. r in y; IrWI-I11 MECHANICAL M3.0 STATION #17 MAIN LEVEL MECHANICAL PLANS 17. a Itumn rm PROJECT LOCATION ELECTRICAL E0.00 ELECTRICAL SYMBOLS AND ABBREVIATIONS E3.10 STATION #17 MAIN LEVEL ELECTRICAL PLANS E3.20 STATION #17 RISER DIAGRAMS E4.00 ELECTRICAL DETAILS 9 10 W }ieat(�cl�e ChWVVnm' L+lvLL9fHtM APPROVED Mike Theisen 04/21/2021 2018 ICC / 2020 NEC Ok +N heat's o �O PERMIT SET West Metro Fire Station Generators 10901 West 38th Ave. Wheat Ridge, CO 80033 WEST METRO FIRE 433 South Allison Parkway, Lakewood, Colorado 80226 WOLD ARCHITECTS AND ENGINEERS 332 Mi... n Si ,e,, Suite W2000 Saint Paul, MN 55101 .1d.... 1 651 227 7773 Set No: Comm No: 999999 A B C D E E M 1 2 MECHANICAL SYMBOLS PRESSURE GAGE ---EZ3— FLEXIBLE CONNECTION DIRECTION OF FLOW CONCENTRIC REDUCER --1 ECCENTRIC REDUCER a ELBOWDOWN ELBOWUP —a TEE CONNECTION DOWN 0— TEE CONNECTION UP PIPING CONNECTION CAPPED PIPE CONNECT TO EXISTING UNION PRESSURE REDUCING VALVE LUBRICATED PLUG GAS COCK MECHANICAL LINETYPES NG NATURAL GAS PIPING AD AREA DRAIN GR GRILLE AFF ABOVE FINISHED FLOOR HB HOSE BIBB AHAP AS HIGH AS POSSIBLE HCW HARD COLD WATER BFF BELOW FINISHED FLOOR HP HORSE POWER BLDG BUILDING HW HOT WATER BSMT BASEMENT INV INVERT BTM BETWEEN KW KILOWATT CB CATCH BASIN LAT LEAVING AIR TEMPERATURE CFM CUBIC FEET/MINUTE LWT LEAVING WATER TEMPERATURE CHW CIRCULATING HOT WATER MAX MAXIMUM CLG CEILING MBH 1000 BTU CO CLEANOUT MECH MECHANICAL CONCR CONCRETE MH MANHOLE CONTR CONTRACTOR MIN MINIMUM CW COLD WATER NTS NOT TO SCALE DS DRY BULB OA OUTSIDE AIR DEG DEGREE OBD OPPOSED BLADE DAMPER DIA DIAMETER ORD OVERFLOW ROOF DRAIN DIFF DIFFUSER P -t PLUMBING FIXTURE NUMBER EAT ENTERING AIRTEMPERATURE PST PRESSURE AND THERMOSTATIC EDR SQUARE FEET RADIATION PD PRESSURE DROP EFF EFFICIENCY PLBG PLUMBING EL ELBOW QUAN QUANTITY ELEC ELECTRICAL RA RETURNAIR ELEV ELEVATION RD ROOF DRAIN EWT ENTERING WATER TEMPERATURE REG REGISTER EXH EXHAUST REQ'D REQUIRED EXIST EXISTING RPM REVOLUTIONS/MINUTE F DEGREES FAHRENHEIT SA SUPPLY AIR F&T FLOAT AND THERMOSTATIC SCW SOFT COLD WATER FD FLOOR DRAIN BHT SHEET FH FIRE HYDRANT SP STATIC PRESSURE FLA FULL LOAD AMPS TO TEMPERATURE DIFFERENCE FLR FLOOR VTR VENT THROUGH ROOF FTR FINNED TUBE RADIATION W/ WITH GEN GENERAL W8 WET BULB GPM GALLONS/MINUTE WH WALL HYDRANT 3 NOTES: PIPE SIZED IN ACCORDANCE WITH 2O15 INTERNATIONAL FUEL GAS CODE TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE NATURAL GAS, INLET PRESSURE LESS THAN 2 PSI, PRESSURE DROP 0.5 IN. W.C. NOT TO SCALE 1-1 "NG MINIMUM 12"—� FINISHED GRADE DIRT LEG NOT TO SCALE GENERATOR BY DIV. 26 LUB. GAS COCK CONTRACTOR PIPE UNION NOTE: THE FIRST 12" OF BACKFILL SHALL BE SAND OR FINE GRAVEL LESS THAN %" IN DIAMETER. THE REMAINDER OF THE BACK FILL SHALL BE VOID OF ROCKS, FROZEN EARTH, AND FOREIGN MATERIAL OVER 6" IN DIAMETER. *LIN PIPING DETAIL NOT TO SCALE PROVIDE TRACER WIRE FOR NON- METALLIC PIPE (TVP) 4 MAIN LEVEL DEMO PLAN 1/8" = 1'-0" DEMOLITION PLAN GENERAL NOTES 1. MECHANICAL CONTRACTOR SHALL DETERMINE LIMITATIONS AND/OR CONFLICTS RELATIVE TO THE EXECUTION OF HIS WORK PRIOR TO BID. VERIFY EXACT DETAIL OF INSTALLATION REQUIRED TO PROVIDE SYSTEMS SHOWN WITHIN SPACE INTENDED. 2. ALL EXISTING SERVICES SHALL BE MAINTAINED AT ALL TIMES, UNLESS OTHERWISE INDICATED ON THE PLANS. COORDINATE DISRUPTION OF SERVICES WITH OWNER TO PROVIDE AN ACCEPTABLE TIME FOR DOWN TIME. 3. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING AND PATCHING OF EXISTING CONSTRUCTION UNLESS OTHERWISE NOTED ON PLANS. NO CUTTING OF STRUCTURAL MEMBERS OR STRUCTURE WHICH WILL DETERIORATE THE INTEGRITY AND STRENGTH OF THE BUILDING WILL BE ALLOWED WITH OUT WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER. 4. THE MECHANICAL CONTRACTOR SHALL REMOVE ALL EXISTING CEILING TILES AND GRIDS AS REQUIRED FOR INSTALLATION OF NEW WORK. ANY DAMAGED TILES AND OR GRIDS SHALL BE REPLACED WITH NE W TO MATCH AT THE CONTRACTORS EXPENSE. 5. THE MECHANICAL CONTRACTOR SHALL REMOVE ALL SYSTEMS SHOWN BOLD AND DASHED. ALL SYSTEMS NOT SHOWN BOLD AND DASHED SHALL REMAIN. 6. PATCH AND REPAIR OPENINGS THROUGH WALLS AND FLOORS WHERE MECHANICAL SYSTEMS WERE REMOVED TO MATCH EXISTING AND TO MAINTAIN FIRE RATING. WALL FINISHED BY OTHERS. DEMOLITION PLAN KEYED NOTES: O EX GENERATORTO BE REMOVED BY ELEC. CONTRACTOR. O DEMO EX GAS PIPE FROM GENERATOR BACK TO MAIN AND AND CAP. DEMO AND REMOVE ALL ASSOCIATED HANGERS AND SUPPORTS. 5 6 1 8 HYDRONIC PLAN GENERAL NOTES: 1. ALL RISES AND DROPS IN PIPING ARE NOT NECESSARILY SHOWN. LAYOUT ROUTING AND )THEIR TRADES BEFORE MAIN LEVEL MECH PIPING PLAN 1/8" = 1'-0" 'OR SHALL BE G AND PATCHING OF THERW1SE NOTED ON )F STRUCTURAL WHICH WILL ITV AND STRENGTH OF OWED WITHOUT WRITTEN JCTURAL ENGINEER. ETERS, GAUGES, AND = ACCESSIBLE CEILINGS. 'URE SENSOR LOCATIONS DING ELEMENTS, 3CTRICAL SWITCHES. 'IONS AS REQUIRED TO PMENT TO BE 3/4 D. JOIST WEBS WHERE WITH THE 'RADES AND TO i. COORDINATE SS BRACING TO ENSURE tACTOR SHALL REMOVE S AND GRIDS AS ION OF NEW WORK. ANY RIDS SHALL BE ATCH AT THE tACTOR SHALL BE ]UIRED REINFORCEMENT UCTURAL MEMBERS FOR IFER TO "MECHANICAL F DETAIL" FOR -S. ED NOTES: ING AND PATCHING IN XTENTS OF TRENCHING AND -TE DRIVE. MAINTAIN MINIMUM AND ELECTRICAL CONDUITS. XTENTS OF TRENCHING AND .T DRIVE. MAINTAIN MINIMUM 5' WD ELECTRICAL CONDUITS. PERMIT SET WEST METRO FIRE STATION GENERATORS Station #17 10901 W 38th Ave. Wheat Ridge, CO 80033 WEST METRO FIRE 433 South Allison Parkway Lakewood, Colorado 80226 WOLD ARCHITECTS AND ENGINEERS 1553 Plate Strea, Suite 201 Denver, Colorado 80202 woldae.mm 1 303 928 8800 �NDO LICF MARS : C sY.37.441 0.0. I hereby certify that his plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed PROFESSIONAL ENGINEER underthe laws of the State of COLORADO License KEVIN MARSHALL Number: 37441 Date 08/07/2020 Revisions T Comm: 08/ 0 30 Date: 08/072/2 020 Drawn: JS Check: JC North STATION #17 MAIN LEVEL MECHANICAL PLANS Scale: 1/8" =1'-0" M3.0 EXISTING LOADS: DOMESTIC WATER HEATER: 38 MBH RANGE/OVEN: 38 MBH FURNACE 1: 100 MBH FURNACE2: 100 MBH FURNACE3: 120 MBH UNIT HEATER 1: 30 MBH UNIT HEATER 2: 50 MBH UNIT HEATER 3: 45 MBH UNIT HEATER 4: 45 MBH GAS METER UNIT HEATER 5: 45 MBH TOTAL: TOTAL: 611 MBH 1,858 CFH OGENERATOR 1,24] CFH ABOVE GRADE BELOW GRADE 17 1-1/ - SCH 40 STEEL @60 FT EQUIV. OR 2" POLYETHYLENE PLASTIC PIPE d) 60 FT EQUIV. NOTES: PIPE SIZED IN ACCORDANCE WITH 2O15 INTERNATIONAL FUEL GAS CODE TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE NATURAL GAS, INLET PRESSURE LESS THAN 2 PSI, PRESSURE DROP 0.5 IN. W.C. NOT TO SCALE 1-1 "NG MINIMUM 12"—� FINISHED GRADE DIRT LEG NOT TO SCALE GENERATOR BY DIV. 26 LUB. GAS COCK CONTRACTOR PIPE UNION NOTE: THE FIRST 12" OF BACKFILL SHALL BE SAND OR FINE GRAVEL LESS THAN %" IN DIAMETER. THE REMAINDER OF THE BACK FILL SHALL BE VOID OF ROCKS, FROZEN EARTH, AND FOREIGN MATERIAL OVER 6" IN DIAMETER. *LIN PIPING DETAIL NOT TO SCALE PROVIDE TRACER WIRE FOR NON- METALLIC PIPE (TVP) 4 MAIN LEVEL DEMO PLAN 1/8" = 1'-0" DEMOLITION PLAN GENERAL NOTES 1. MECHANICAL CONTRACTOR SHALL DETERMINE LIMITATIONS AND/OR CONFLICTS RELATIVE TO THE EXECUTION OF HIS WORK PRIOR TO BID. VERIFY EXACT DETAIL OF INSTALLATION REQUIRED TO PROVIDE SYSTEMS SHOWN WITHIN SPACE INTENDED. 2. ALL EXISTING SERVICES SHALL BE MAINTAINED AT ALL TIMES, UNLESS OTHERWISE INDICATED ON THE PLANS. COORDINATE DISRUPTION OF SERVICES WITH OWNER TO PROVIDE AN ACCEPTABLE TIME FOR DOWN TIME. 3. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING AND PATCHING OF EXISTING CONSTRUCTION UNLESS OTHERWISE NOTED ON PLANS. NO CUTTING OF STRUCTURAL MEMBERS OR STRUCTURE WHICH WILL DETERIORATE THE INTEGRITY AND STRENGTH OF THE BUILDING WILL BE ALLOWED WITH OUT WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER. 4. THE MECHANICAL CONTRACTOR SHALL REMOVE ALL EXISTING CEILING TILES AND GRIDS AS REQUIRED FOR INSTALLATION OF NEW WORK. ANY DAMAGED TILES AND OR GRIDS SHALL BE REPLACED WITH NE W TO MATCH AT THE CONTRACTORS EXPENSE. 5. THE MECHANICAL CONTRACTOR SHALL REMOVE ALL SYSTEMS SHOWN BOLD AND DASHED. ALL SYSTEMS NOT SHOWN BOLD AND DASHED SHALL REMAIN. 6. PATCH AND REPAIR OPENINGS THROUGH WALLS AND FLOORS WHERE MECHANICAL SYSTEMS WERE REMOVED TO MATCH EXISTING AND TO MAINTAIN FIRE RATING. WALL FINISHED BY OTHERS. DEMOLITION PLAN KEYED NOTES: O EX GENERATORTO BE REMOVED BY ELEC. CONTRACTOR. O DEMO EX GAS PIPE FROM GENERATOR BACK TO MAIN AND AND CAP. DEMO AND REMOVE ALL ASSOCIATED HANGERS AND SUPPORTS. 5 6 1 8 HYDRONIC PLAN GENERAL NOTES: 1. ALL RISES AND DROPS IN PIPING ARE NOT NECESSARILY SHOWN. LAYOUT ROUTING AND )THEIR TRADES BEFORE MAIN LEVEL MECH PIPING PLAN 1/8" = 1'-0" 'OR SHALL BE G AND PATCHING OF THERW1SE NOTED ON )F STRUCTURAL WHICH WILL ITV AND STRENGTH OF OWED WITHOUT WRITTEN JCTURAL ENGINEER. ETERS, GAUGES, AND = ACCESSIBLE CEILINGS. 'URE SENSOR LOCATIONS DING ELEMENTS, 3CTRICAL SWITCHES. 'IONS AS REQUIRED TO PMENT TO BE 3/4 D. JOIST WEBS WHERE WITH THE 'RADES AND TO i. COORDINATE SS BRACING TO ENSURE tACTOR SHALL REMOVE S AND GRIDS AS ION OF NEW WORK. ANY RIDS SHALL BE ATCH AT THE tACTOR SHALL BE ]UIRED REINFORCEMENT UCTURAL MEMBERS FOR IFER TO "MECHANICAL F DETAIL" FOR -S. ED NOTES: ING AND PATCHING IN XTENTS OF TRENCHING AND -TE DRIVE. MAINTAIN MINIMUM AND ELECTRICAL CONDUITS. XTENTS OF TRENCHING AND .T DRIVE. MAINTAIN MINIMUM 5' WD ELECTRICAL CONDUITS. PERMIT SET WEST METRO FIRE STATION GENERATORS Station #17 10901 W 38th Ave. Wheat Ridge, CO 80033 WEST METRO FIRE 433 South Allison Parkway Lakewood, Colorado 80226 WOLD ARCHITECTS AND ENGINEERS 1553 Plate Strea, Suite 201 Denver, Colorado 80202 woldae.mm 1 303 928 8800 �NDO LICF MARS : C sY.37.441 0.0. I hereby certify that his plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed PROFESSIONAL ENGINEER underthe laws of the State of COLORADO License KEVIN MARSHALL Number: 37441 Date 08/07/2020 Revisions T Comm: 08/ 0 30 Date: 08/072/2 020 Drawn: JS Check: JC North STATION #17 MAIN LEVEL MECHANICAL PLANS Scale: 1/8" =1'-0" M3.0 E A B C D E E 5 ELECTRICAL SYMBOL SCHEDULE SYMBOL DESCRIPTION SYMBOL DESCRIPTION HEIGHT MOUNTING SYMBOL DESCRIPTION MOUNTING HEIGHT SYMBOL DESCRIPTION MOUNTING HEIGHT ANGLE GENERAL ELECTRICAL SYMBOLS CONDUIT LIGHTING JUNCTION BOX N . COMMUNICATION DEVICES QUAN QUANTITY POWER AND MOTOR DEVICES UNDERGROUND ELECTRICAL DEVICE ABBREVIATIONS. @ AT CAN CABLE TELEVISION A. DEVICES SHALL BE MOUNTED AT THE HEIGHT INDICATED, UNLESS NOTED OTHERWISE. HEIGHTS ARE MEASURED TO FROM DEVICE CENTER TO FINISHED FLOOR DEVICES NEC NATIONAL ELECTRICAL CODE UG UNDERGROUND �O RECESSED LUM INAI RE(TYPE DENOTED) CB WG PAGINGIINTERCOM SPEAKER HORN ASSEMBLY- P A. OR AS INDICATED (314"C. BUSHED EMT TO ACCESSIBLE CEILING).WG=WIREGUARD B0„ � RECEPTACLE NOTATION .## INDICATES THE FOLLOWING. AS ABOVE COUNTER, BOTTOM OF BOX 2" ABOVE BACKSPLASH IS ISOLATED GROUND RCPT RECEPTACLE SURFACE MOUNTED LUMINAIRE (TYPE DENOTED) UNIT HEATER DS�J �4 WG LOUD SPEAKER HORN ASSEMBLY- PA OR SOUND SYSTEM AS INDICATED, VERIFY MOUNTING HEIGHT. (314"C. BUSHED EMT TO ACCESSIBLE CEILING) .WG=WREGUARD " INCHES MOUNTED IN BLOCKIBRICK WALLS SHALL CORRESPOND WITH BLOCKIBRICK COURSING. SEE MASONRY BACKBOX MOUNTING HEIGHTDETAIL. CLOSED CIRCUIT TELEVISION GFI INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER GFI CB GROUND FAULT CIRCUIT INTERRUPTER IN CIRCUIT BREAKER TR TAMPER RESISTANT KILOVOLT -AMPERE B. ALL MOUNTING HEIGHTS INDICATED ARE FROM THE FINISH FLOOR TO THE CENTER OF THE BOX. C. ON DEMOLITION DRAWINGS, DASHED ELECTRICAL ITEMS DENOTES EXISTING ITEMS TO BE REMOVED SOLID SCREENED RECD USE (2) USE PORTS INTEGRALWITH RECEPTACLE WP WEATHERPROOF UNO UNLESS NOTED OTHERWSE LUMINAIRE ON EMERGENCY CIRCUIT SWITCHED CLOTHES DRYER OS -{ Z# 0 AV SPEAKER WTH BACKBOX(WALL OR CEILING), VERIFY MOUNTING HEIGHT .PA=SPEAKER FOR P A. SYSTEM, V=WITH INTEGRAL VOLUME CONTROL KNOB ,FA=FIRE ALARM, AV=SPEAKER FOR LOCAL AV SYSTEM, Z# = ZONE NUM BER. 314"C. BUSH ED EMT TO ACCESSIBLE CEI LING). MOUNT 12" BELOW CEILING ORASINDICATED ON PLANS. CRT O LUMINAIRE ON EMERGENCY CIRCUIT , UNSWTCHED KILOVOLT -AMPERE REACTIVE NFS SURFACE MOUNTED DUPLEX/ QUAD RECEPTACLES AND DATA OUTLETS RL ® STRIP LIG HT LUM INAI RE, FOR SUSPENDED M OUNTING HEIGHTS, SEE DRAWINGS. UNDERGROUND TELEPHONE DISH MICROPHONE OUTLET WALL OR CEILLING. (112T BUSHED EMTTO ACCESSIBLE CEILING). 18" 1 POLE (2P 3P, 4P, ETC) RECEPTACLES WTH GROUND FAULT CIRCUIT INTERRUPTER CEILING RAI ELECTRICAL ITEM S DENOTES EXISTING ITEM S TO REM Al N, UNLESS NOTED OTHERWISE NIC SG AWINGS D. ON NEW WORECTRICAL ITEMS ER AND DENOTESEXISTING ITEMS TO SCREEITEMS TO REMAIN, SOLID ELECTRICAL ITEMS DENOTES NEW ITEMS, ALITEMS DEMO ES NEW REMAIN SOLID ELECTRICAL FC WALL MOUNTED LUMINAIRE, SEE REFLECTED CEILING PLAN FOR MOUNTING HEIGHT. UV a AUXILIARY INPUT CONNECTOR. (112T BUSHED EMTTO ACCESSIBLE CEILING). 18” � DUPLEX RECEPTACLE ON NORMAL CIRCUIT 18" COMPRESSOR UNLESS NOTED OTHERWISE 0 LINE AR PENDANT LUMINAIRE, FOR SUSPENDED MOUNTING HEIGHTS, SEE DRAWINGS NEW LOCATION #Od INTERCOM M= MASTER STATION. (112"C. BUSHED EMTTO ACCESSIBLE CEILING). TOP AT 48"AFF ii DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT 18" A DEVICES TO BE DEMOLISHED. �— L'f L—J `^� EXISING DEVICES TO REMAIN r/, (--`/ > CONN CONNECTION N.O. NORMALLY OPEN V VOLT CIRCULAR PENDANT LUMINAIRE, FOR SUSPENDED MOUNTING HEIGHTS, SEE DRAWINGS SANITARY AUTOMATIC FLUSH # �I #V COMMUNICATIONS OUTLET FORK WALL OR CEILING ( ).(BUSHED EMT TO ACCESSIBLE CEILING SPACE OR AS INDICATED) # =SEE DETAIL SHEETS. CONT CONTINUATION OR CONTINUOUS RECEPTACLE (SINGLE) 18" NPF TRACK LIGHT LUMINAIRE (WITH HEADS OR PENDANTS), LENGTHAND MOUNTING AS NOTED ON DRAWINGS . SC GH VOLUME CONTROL. (112"C. BUSHED EMTTO ACCESSIBLE CEILING) . 46" FRZ DOUBLE DUPLEX RECEPTACLE (QUAD) ON NORMAL CIRCUIT 18" ABOVE CEILING y CONTRACTOR NEW DEVICES . //� > a LIGHT EXIT LIGHT -FACE SH OWN SHADED, PLAN IN DICATES CEILING OR WALL MOUNTING AND DI RECTI ONAL ARROWS. NOTTO SCALE I=I Y CALL BACK SWITCH. (112"C. BUSHED EMT TO ACCESSIBLE CEILING). 48" VERTICAL DOUBLE DUPLEX RECEPTACLE (QUAD) ON EMERGENCY CIRCUIT 18" ® 7 KEYEDNOTE. o EMERGENCY LIGHTING UNIT- TWO HEAD MOUNTING AS INDICATED ON DRAWINGS. LTG LIGHTING NNIDEO CAMERA CLOSED CIRCUIT. (WALL OR CEILING MOUNTED, VC. BUSHED EMT TO ACCESSIBLE CEILING). MOUNT PER DRAWINGS. CAMERABYOTHERS. ® SPECIAL PURPOSE OUTLET, RECESSED, MOUNTPERDWGS. 18" # O FEEDER OR EQUIPMENT DRAWING NOTE. ,^,I�� VLJ °0 POLE POLE MOUNTED SITE LUMINAIRE-SINGLE SQUARE HEAD. NUMBER OF ASSHONM. ABOVE FINISHED FLOOR C C CLOCK OUTLET. (314"C. BU SH ED EMT TO ACCESSIBLE CEI LING FOR WRED CLOCKS ONLY). D=DOUBLEFACED 00" 6 RECESSED CEILING MOUNTED SINGLE OR DUPLEX RECEPTACLE WI ADDITIONAL 10'FLIX MCIAC SLACK (COILED) FORFUTUREDEVICE RELOCATION. OVERHEAD E# ELEVATION, SEE DETAIL #ON SHEET E#. VOL POLE MOUNTED SITE LUMINAIRE- PEDESTRIAN OR BOLLARD STYLE. HOOD EXHAUST HOOD BELIJAUDIBLE DEVICE. (314"C. BUSHED EMTTO ACCESSIBLE CEILING) 95" CT USE ONLY DEVICE, (4) USE CHARGING PORTS 18" LOWVOLTAGE LIGHTING CONTROL OVERLOADS D# WALL DATA AND COMMUNICATIONS OUTLET. (BUSHED EMT TO ACCESSIBLE CEILING SPACE OR AS INDICATED). D# INDICATES TYPE OF OUTLET SEEDETAILSHEETS 18" JD -I CEILING OR WALL M OUNTED JUNCTION BOX WITH REQUIRED OVERPLATE - P AN INDICATES FUNCTION CLG, 18" AFI ARC FAULT CIRCUIT INTERRUPTER CTR POWER DISTRIBUTION AND EQUIPMENT � D# WAP CEILING DATA OUTLET AND WIRELESS ACCESS POINT. (BUSHED EMT TO ACCESSIBLE CEILING SPACE OR AS INDICATED( D# INDICATES TYPE OF OUTLET. SEEDETAILSHEETS. SPEAKER I MSP MOTOR RATED SWITCH AND PILOT 46" REFRIGERATOR SVNTCHING NOTATION. ##INDICATES THE FOLLOWING. qfi CU RSD WALL MOUNT DATA OUTLET FOR ROOM SCHEDULING EQUIPMENT. REFER TO DETAILS. 46" H MS MOTOR RATED SWITCH. 46• SPARE SWTCHBOARD WTH CONCRETE PAD. FLOOR MOUNTED. WTH 3 THREE-WAY 4 FOUR-WAY D DIMMER RELOCATE AL ALUMINUM MIC M OM ENTARY CONTACT 0 RELAYICONNECTION CABINET, WALL M OUNTED, WITH TOP AT 72" AFF SR K KEYED LV LOWVOLTAGE MC MOMENTARY CONTACT WG VV> WALL PHONE COMMUNICATIONS OUTLET.(1"BUSHEDEMTTO ACCESSIBLE CEILING SPACE).SEEDETAILSHEETS qfi^ H MSS MOTOR STARTER SWITCH WITH MOTOR RUNNING PROTECTION ADD RELAY IF CONTROL CONTACTS ARE REQUIRED). qfi. DOMESTIC WATER CIRCULATING PUMP MCB MAIN CIRCUIT BREAKER PE PNEUMATIC ELECTRIC SS STAINLESS STEEL WH WATER HEATER OS INTEGRAL OCCUPANCY SENSOR ELECTRIC OVEN >Z PANELBOARD, WALL MOUNTED WITH TOP AT 72" AFF PL LIGHTED LIGHT TD TIMEMEDELAY TIME MCC MOTOR CONTROL CENTER DISTRIBUTED SYSTEM (DAB) . CLG CLG LEI DISCONNECT SWITCH - NON FUSED. 8101, WTHOUT FIRE ALARM DEVICES VENDING MACHINE LA DISCONNECT SWITCH - FUSED. fi'S" ATS AUTOM WALLO FLOORIC MOONSFER SWITCH, WALL OR FLOOR MOUNTED MAIN DISTRIBUTION CENTER EACH SYMBOL DENOTES A SINGLE POLE LIGHT SWITCH NMEN MULTIPLE SWTCHES ARE SHOWN, LOCATEALLUNDER SINGLE MULTI -SWITCH COVERPLATE POWER FACTOR SIS STOPISTART PUSHBUTTONS WP WEATHERPROOF IT I TRANSFORMER, WITH SIZE AS NOTED. SEERISERDIAGRAM, SCHEDULE OR FLOOR PLANS, VERIFY. AQ -STAT AQUASTAT MDP MAIN DISTRIBUTION PANEL ® MOTOR STARTER. 8101, L L PC Pc PHOTOCELL-WALL,CEILING, ORROOFMOUNTED, SEEDRAWNGS. Fo FIRE ALARM ANNUNCIATOR PANEL, TOP AT 85"AFF AUTOMATIC TRANSFER SWITCH FOL FIBER OPTIC LINE PB PULLBOX PNL COMBINATION STARTERIDISCONNECT SWITCH. 810" LD D OS# OS# OCCUPANCY SENSOR- WALL OR CEILING CEILING MOUNT OS# INDICATES TYPE PER OCCUPANCY SENSOR SCHEDULE 46" FACP FIRE ALARM CONTROL PANEL (MASTER) TOPAT68" AFF AUDIOVISUAL FS FUSIBLE SWITCH HH HANDHOLEHF1 PP POWER POLE SURF SURFACE MOUNTED XFR TRANSFER •• PUSHBUTTON -WALL MOUNTED. 35" 38" IF] EMERGENCY LIGHTING RELAY (UL 824) -SEE WIRING SCHEMATICON DETAIL SHEETS. NAC FIREALARM NOTIFICATION APPLIANCE CIRCUIT PANEL. MOUNT TOP fit"AFF PLUS OR MINUS 2". TOPAT 62 t 2" AFF PAIR SW SWTCH MCC MOTOR CONTROL CENTER(WICONCRETE PAD), FLOOR MOUNTED. HTR HEATER Hk ADA PUSHBUTTON - WALL MOUNTED. 33" EXTERIOR 42" INTERIOR PRIMARY SECURITY DEVICES SWTCHBOARD � FIRE ALARM MANUAL PULL STATION. 4fi" BATT BATTERY HV PLUG-IN BUS DUCT SWTCH, SIZE AS INDICATED AND SPECIFIED. MOA MULTI OUTLET ASSEMBLY PROD PROJECTION SYM SYMMETRICAL © POWER POLE (DEVICES AS INDICATED) BD BOARD HWP HYDRONIC WATER PUMP rl-J VERIFY MOUNTING HEIGHT. PRV POWER ROOF VENTILATOR TERM �F { FIRE ALARM HORN (AUDIBLE) , WALL MOUNTED. 84" BLDG BUILDING O METERISOCKET ASSEMBLY, MOUNT TOP AT 72" AFF ## © SECURITYDEVICE. ##INDICATES THE FOLLOWING. CM CONTROL MODULE DC DOOR CONTACTS (MONITORING) TL TWST LOCK MOTOR, SEE MOTOR AND EQUIPMENT SCHEDULE BAS B CFL} OTT FI RE ALARM CHIME(WP FOR EXTERIOR MOUNTING). B=BELL . 84" MT BRANCH CIRCUIT, FEEDER, AND RACEWAY PVC EL ELECTRIC LOCKILATCH ES ELECTRIC STRIKE GB GLASS BREAK DETECTOR IF INFARED DEFECTOR TR TAMPER RESISTANT SPT# ®FB# POKE-THROU GH(PT)ORFLOOR BOX (FB), FULLY RECESSED IN FLOOR. REFERTO POKE -THROUGH AND FLOOR BOX SCHEDULE. FLR ## ## FIRE ALARM STROBE (VISUAL) DEVICE (WALL OR CEILING MOUNTED) 84" CLNG MTC EMPTY CONDUIT PWR INDICATES CONDUIT ROUTED BELOW, IN FLOOR STRUCTURE, BELOW _____ THERMOSTAT ML MAGNETIC LOCK RIX REQUESTTO EXIT XP EXITPUSHBU70N, MOUNTATADAHT WALL MOUNTED FURNITURE FEED. 18" #d�k^— uLF_I FIRE ALARM HORNISTROBE (COMBINATION) (WALL OR CEILING MOUNTED). 84"CLNG TTC TELEPHONE TERMINAL CABINET GRADE, OR AS NOTED. ## INDICATES THE FOLLOWING . WG=WIRE GUARD, INCANDESCENT J CORD REEL I CORD AND PLUG SET- CEI LING MOUNTED. SEE PLANS NTC TELEVISION TERMINAL CABINET WP=WEATHERPROOF (D-0 FOR MORE INFORMATION. IF INFRARED = GROUND CR S❑{ CRKEH CR= CARD READER ROUGH -IN ATADA HEIGHT CRY= CARD READER WITH INTEGRADED KEY PAD REFER TO DETAILS. 46" TYPICAL ## FIRE ALARM SPE4KERISTROBE (COMBINATION) (WALL OR CEILING MOUNTED) 84^CLNG NURSE CALL DEVICES DR aH DOOR RELEASE, MOUNT PER DWGS. 46" INDICATES CONDUIT IS SURFACE M OUNTED ## INDICATES THE FOLLOWING . WG=WIRE GUARD, WP=WEATHERPROOF #� NURSE CALL SYSTEM DEVICE 4" SQUARE BOX WTH 314"C. BUSHED EMT INDICATO TES HEFOLOWISSIBLE NG, UNG. #INDICATES THE FOLLOWING. A= STAFF ASSIST REQUEST B=CODE BLUE D = DUTY STATION, 3 -GANG BOX qfi" INDICATES CONDUIT ROUTED CONCEALED ABOVE FLOOR OR GRADE (IN CEILING OR WALL) INDICATES CONDUIT UP Version 3.08.20 ## ZE FIRE ALARM SPEAKER (WALL OR CEILING MOUNTED). ##INDIATHERCATES PROHE OLLOVNNG. WG=WIRE GUARD, WP=WEATHER PROOF 84",CLNG ILSH VI❑S{ VIDEO INTERCOM WITH INTEGRATED DOOR RELEASE ,MCUNT WITH ACTIVATION BUTTON AT MAXIMUM 48" BUTTON LOCATION VARIES BY DEVICE MANUFACTURERJ. WALLMOUNT, 1 "CONDUIT TOACCESSIBLE CEILING. REFER TO DETAIL. = INTERCOM VI = VIDEO INTERCOM, F[V] FIREMAN PHONE JACK, MOUNT TOP 54" AFF PLUS OR MINUS 2". INDICATES CONDUIT DOWN NoaH KEYPAD, VERIFY M OUNTING HEIGHT WITH DWGS. 46" E = EMERGENCY (PULLCORD) E1= EM ERG EN CY (PU SH BUTTON) L= DOME LIGHT, ABOVE DOOR HEADER D[�MAGN ETI C DOOR H OLD -OPEN (WALL M OUNTED), M CUNT PER DWGS. M = MASTER STATION, 1 -GANG BELOW COUNTER TOP FL IF] SPRINKLER FLOW -SWITCH, MOUNTPERDWGS. CONDUIT STUB- TERMINATION INDICATED BY NOTE DB ❑S { DURESS BUTTON 46" M1 = MASTER STATION WALL -MOUNTED, 3 -GANG BOX P=PATIENT, 3 -GANG BOX P1 =PATIENT WI EXTRA JACK FOR PILLOW SPEAKER, 3 -GANG BOX TS ❑F SPRINKLER TAM PER-SWTCH, MOUNTPERDWGS. CONDUIT CONTINUATION MC❑S{ MASTER CONTROL STATION R= RELAY , 4 -GANG BOX S= STAFF RESPONDER, 3 -GANG BOX T=TV MOUNT SAME HEIGHT AS ADJACENT RECEPTACLE MD MD f{)Si (� MOTIONDETECTOR, ARROW INDICATES DIRECTION. (WALLOP CEILING MOUNTED). SL# CONDUIT SLEEVE WTH BUSHINGS ON BOTH ENDS, SEE SCHEDULE FOR QUANTITIES AND SIZES OF SLEEVES F 0S -CO F O os S -H SMOKE DETECTOR -CEILING MOUNTED. S -CO= COMBINATION SMOKE AND CARBON MONOXIDE DETECTOR S -H- COMBINATION SMOKE AND HEAT DETECTOR 0 12"X4" CABLE TRAY (WIDTH XDEPTH) CS 1H CONTROL SWTCH- INTERVIEW ROOM ACTIVITY. REFER TO DETAIL. 46" O DOM E LIGHT, CEI LING M OUNTED. 8 #° ,#°= HEAT DETECTOR (RATE-OF-RISE)FIXTEDTEMPERATURE- CEILING MOUNTED. 1"C,3#4+1#3G INDICATES 1" CONDUIT (3)N0.4AWG CONDUCTORSAND (1)N0.3 GROUND WRE IL❑S IL❑S{ INDICATOR LIGHT -INTERVIEW ROOM ACTIVITY. REFERTO DETAIL. #V[V}{ MOUNT PER DWGS , . # WANDERING PATIENT DEVICEINDICATES THE FOLLOWING. KP=KEYPAD 42" SDo- DUCT SMOKE DETECTOR MOUNT PER DWGS. C❑S { C❑S SURVEILLANCE CAMERA. (WALLOP CEILING MOUNTED VC BUSHED EMTTO ACCESSIBLE RACEWAY ASSEMBLY . PROVIDE AS SPECIFIED, UNLESS RX= RECIEVER � NOTEDSURFACE NOTED OTHERVNSE. CEILING). I [F] FIRE ALARM I N DIVIDUAL ADDRESSABLE MODULE,MOUNT PER DWGS. MULTI -LENS SURVEILLANCE CAMERA. (WALLOP CEILING MOUNTED ,1 "C. BUSHED EMT TO ACCESSIBLE CEILING). *[a LOCK, DC= DOOR CONTACT. 0 IF] FIRE ALARM CONTROL MCOU LE,MOUNT PER DWGS. FIS D FIREISMOKE DAMPER, MOUNT PER DWGS. 6 1 7 GENERAL ELECTRICAL NOTES A. INSTALL CONCEALED CONDUIT WITH FLUSH J.B.'S IN WALLS AND CEILINGS UNLESS NOTED OTHERWISE. IN FINISHED AREAS WITH INACCESSIBLE WALLS OR CEILINGS, PROVIDE SURFACE (WIREMOLD) RACEWAY, PAINT TO MATCH COLOR OF ADJACENT WALL OR CEILING. B. RACEWAYS SHALL CONTAIN A GROUNDING CONDUCTOR. C. CIRCUITS SUPPLYING LINE TO NEUTRAL LOADS SHALL HAVE DEDICATED NEUTRALS, i.e. ONE NEUTRAL PER PHASE. NEUTRAL CONDUCTORS SHALL HAVE TRACER STRIPE ALONG ENTIRE LENGTH INDICATING ASSOCIATED PHASE. D. BUILDING CONDUCTORS SHALL BE THWN/THHN. CONDUCTORS IN UNDERGROUND CONDUIT OUTSIDE OF BUILDINGS SHALL BE XHHW. E. NUMBERS AT RECEPTACLES AND LIGHT FIXTURES CORRESPOND DIRECTLY WITH PANELBOARD CIRCUIT NUMBERS AS SCHEDULED. BRANCH CIRCUIT WIRING AND HOMERUNS ARE NOT SHOWN FOR CLARITY. ACCURATE RECORD DRAWING INFORMATION IS TO BE PROVIDED AT THE PROJECT COMPLETION. TYPICAL THROUGHOUT. REFER TO SPECIFICATIONS FOR MATERIALS AND INSTALLATION REQUIREMENTS. F. REFER TO CONTRACT DOCUMENTS FOR SEQUENCE OF CONSTRUCTION AND PHASING OF THE CONTRACT. G. SWITCHES SHALL BE MOUNTED PER ADA REQUIREMENTS, 46" AFF. UNLESS OTHERWISE NOTED, RECEPTACLES AND TELECOMMUNICATION OUTLETS IN FINISHED AREAS SHALL BE MOUNTED 18" AFF. RECEPTACLES IN UN- FINISHED SPACES SHALL BE MOUNTED AT 46" OR 4" ABOVE WORK SURFACE. COORDINATE RECEPTACLE MOUNTING HEIGHTS WITH MILLWORK LOCATIONS, ARCHITECTURAL ELEVATIONS, AND MASONRY COURSING. H. CRITICAL DEVICES/ EQUIPMENT, INCLUDING TELEPHONE, COMPUTER, SECURITY, AND FIRE ALARM, AFFECT ASSOCIATED SYSTEMS BUILDING - WIDE. THESE SYSTEMS MUST REMAIN OPERATIONAL DURING THE CONSTRUCTION. INDIVIDUAL DEVICES MAY BE DISCONNECTED AND/OR RECONNECTED DURING CONSTRUCTION. COORDINATE POWER OUTAGES WITH OWNER. PROVIDE TEMPORARY PANEL(S) AND/OR CIRCUIT(S) AS/IF NECESSARY TO MAINTAIN CONTINUITY. PROTECT FROM PHYSICAL AND DUST DAMAGE. I. THE BUILDING SHALL MAINTAIN POWER THROUGHOUT THE CONSTRUCTION PROCESS. COORDINATE ENERGIZATION OF NEW EQUIPMENT AND THE CORRESPONDING RECONNECTION OF EXISTING AFFECTED ELECTRICAL DISTRIBUTION EQUIPMENT. J. SEE RELATED PLUMBING AND HVAC DRAWINGS FOR LOCATION OF EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. COORDINATE INTERCONNECTION REQUIREMENTS WITH EQUIPMENT SHOP DRAWINGS. K. WIRING FOR MISCELLANEOUS HVAC DEVICES AND CONTROLLERS SUCH AS DAMPER MOTORS, THERMOSTATS, DUCT SMOKE DETECTORS, FREEZESTATS, DIFFERENTIAL PRESSURE SWITCHES, OCCUPIED AND UNOCCUPIED SELECTOR SWITCHES, ALARM LIGHTS, ETC., NOT SHOWN ON ELECTRICAL DRAWINGS IS DIVISION 23 WORK. L. FIELD VERIFY EXISTING CONDITIONS. DISCREPANCIES BETWEEN THE DRAWING AND ACTUAL FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO BIDS. M. MAINTAIN EXISTING CIRCUIT CONTINUITY ON ALL SYSTEMS ON THE SITE THAT ARE EXISTING TO REMAIN. N. PROVIDE ALL CONDUIT HOMERUNS AS 3/4"C. MIN. O. COORDINATE ALL WORK WITH OTHER CONTRACTORS AND OWNER. P. ALL CUTTING AND PATCHING FOR DIV. 26 WORK SHALL BE UNDER SUPERVISION AND APPROVAL OF ARCHITECT. Q. REMOVE AND/OR REINSTALL ELECTRICAL DEVICES IN ALL AREAS OF WORK AS REQUIRED AND REPLACE ANY ELECTRICAL DEVICES DAMAGED BY WORK. NOT ALL DEVICES MAY BE SHOWN ON DRAWINGS. R. PROVIDE ALL BOXES, FITTINGS, CONDUIT, WIRING, TERMINATIONS, EQUIPMENT, ETC, FOR A COMPLETE INSTALLATION. S. BRANCH 20A CIRCUIT CONDUCTORS SHOULD BE SIZED AS FOLLOWS: 120V CCT LENGTH 277V CCT LENGTH AWG < 75' < 130' 12 75'- 120' 130'- 215' 10 120'- 200' 215' - 330' 8 8 ELECTRICAL DRAWINGS EO.00 ELECTRICAL SYMBOLS AND ABBREVIATIONS E1.10 STATION #2- MAIN LEVEL ELECTRICAL PLANS E1.20 STATION #2- RISER DIAGRAMS E2.10 STATION #16- MAIN LEVEL ELECTRICAL PLANS E2.20 STATION #16- RISER DIAGRAMS E3.10 STATION #17- MAIN LEVEL ELECTRICAL PLAN E3.20 STATION #17- RISER DIAGRAMS E4.00 ELECTRICAL DETAILS 0 W hea7,Qo. O 0 �pUing prns c PERMIT SET WEST METRO FIRE STATION GENERATORS WEST METRO FIRE 433 South Allison Parkway Lakewood, Colorado 80226 WOLD ARCHITECTS AND ENGINEERS 1553 Platte Street, Shiite 201 Denver, Colorado 80202 woldae.com 1 303 928 8800 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and mac I am a duly Licensed PROFESSIONAL ENGINEER underthe laws ofthe State of COLORADO License BRADLEY R.JOHANNSEN Number: 0047293 Date 8/20/2020 Revisions Comm: 205030 Date: 8/202020 Drawn : R. Hinks ELECTRICAL ABBREVIATIONS LIST B.Johannsen < ANGLE C CONDUIT J -BOX JUNCTION BOX N . NORMALLY CLOSED QUAN QUANTITY UE UNDERGROUND ELECTRICAL DEVICE ABBREVIATIONS. @ AT CAN CABLE TELEVISION NEC NATIONAL ELECTRICAL CODE UG UNDERGROUND FEET CB CIRCUIT BREAKER KV KILOVOLT NEMA NATIONAL ELECTRICAL RCPT RECEPTACLE UH UNIT HEATER WASH CLOTHES WASHER " INCHES CCN CLOSED CIRCUIT TELEVISION KVA KILOVOLT -AMPERE MANUFACTURER'S ASSOCIATION RECD REQUIRED UNO UNLESS NOTED OTHERWSE DRY CLOTHES DRYER # NUMBER CRT CIRCUIT KVAR KILOVOLT -AMPERE REACTIVE NFS NON-FUSED SAFETY SWITCH RL RELOCATED UT UNDERGROUND TELEPHONE DISH DISHWASHER 1P 1 POLE (2P 3P, 4P, ETC) CLG CEILING RAI KILOWATT NIC NOT IN CONTRACT RSC RIGID STEEL CONDUIT UV UNITVENTILATOR OR ULTRAVIOLET DISP UNDER SINK DISPOSER CMPR COMPRESSOR KNM KILOWATT HOUR NL NEW LOCATION RTU ROOF TOP UNIT EWC ELECTRIC WATER COOLER A AMPERE CONN CONNECTION N.O. NORMALLY OPEN V VOLT FLSH SANITARY AUTOMATIC FLUSH AC AIR CONDITIONER CONT CONTINUATION OR CONTINUOUS LOC LOCATE OR LOCATION NPF NORMAL POWER FACTOR SC SURFACE CONDUIT VA VOLT-AMPERES FRZ FREEZER ACLG ABOVE CEILING CONTR CONTRACTOR LT LIGHT NTS NOTTO SCALE SEC SECONDARY VERT VERTICAL GOSS GOGGLES CABINET ADA AUTOMATIC DOOR ACTUATOR CONV CONVECTOR LTG LIGHTING BHT SHEET VFD VARIABLE FREQUENCY DRIVE HAND HAND DRYER AFF ABOVE FINISHED FLOOR CP CIRCULATING PUMP LTNG LIGHTNING OH OVERHEAD SIM SIMILAR VOL VOLUME HOOD EXHAUST HOOD AFG ABOVE FINISHED GRADE CT CURRENT TRANSFORM ER LV LOWVOLTAGE OL OVERLOADS SIN SOLID NEUTRAL MWV MICROWAVE AFI ARC FAULT CIRCUIT INTERRUPTER CTR CENTER SPKR SPEAKER W WATT REF REFRIGERATOR AHU AIR HANDLING UNIT CU COPPER MAG.S MAGNETIC STARTER PA PUBLIC ADDRESS SP SPARE WI WTH RL RELOCATE AL ALUMINUM MIC M OM ENTARY CONTACT PB PULL BOX SR SURFACE RACEWAY WG WRE GUARD NL NEW LOCATION ALT ALTERNATE DCP DOMESTIC WATER CIRCULATING PUMP MCB MAIN CIRCUIT BREAKER PE PNEUMATIC ELECTRIC SS STAINLESS STEEL WH WATER HEATER OVN ELECTRIC OVEN AMP AMPLIFIER MCC MOTOR CONTROL CENTER PED PEDESTAL SSW SELECTOR SWITCH NO WTHOUT VEND VENDING MACHINE ANNUN ANNUNCIATOR IX EXISTING TO REMAIN MDC MAIN DISTRIBUTION CENTER PF POWER FACTOR SIS STOPISTART PUSHBUTTONS WP WEATHERPROOF PRNT PRINTER AQ -STAT AQUASTAT MDP MAIN DISTRIBUTION PANEL PH PHASE STA STATION ATS AUTOMATIC TRANSFER SWITCH FOL FIBER OPTIC LINE MFR MANUFACTURER PNL PANEL STD STANDARD XFMR TRANSFORMER AV AUDIOVISUAL FS FUSIBLE SWITCH MFS MAIN FUSED DISCONNECT SWTCH PP POWER POLE SURF SURFACE MOUNTED XFR TRANSFER AWG AMERICAN WRE GAUGE MLO MAIN LUGS ONLY PR PAIR SW SWTCH HTR HEATER MMS MANUAL MOTOR STARTER PRI PRIMARY SWBD SWTCHBOARD BATT BATTERY HV HIGH VOLTAGE MOA MULTI OUTLET ASSEMBLY PROD PROJECTION SYM SYMMETRICAL BD BOARD HWP HYDRONIC WATER PUMP MSP MOTOR STARTER PANELBOARD PRV POWER ROOF VENTILATOR TERM TERMINAL BLDG BUILDING MSBD MAIN SWITCHBOARD PT POTENTIAL TRANSFORMER TL TWST LOCK BAS BUILDING AUTOMATION SYSTEM IC INTERRUPTING CAPACITY MT MOUNT PVC POLYVINYL CHLORIDE (CONDUIT) TR TAMPER RESISTANT IS ISOLATED GROUND MTC EMPTY CONDUIT PWR POWER T -STAT THERMOSTAT IMC INTERMEDIATE METAL CONDUIT MTS MANUALTRANSFER SWITCH TTC TELEPHONE TERMINAL CABINET INCAND INCANDESCENT MTR MOTOR, MOTORIZED NTC TELEVISION TERMINAL CABINET IF INFRARED TYP TYPICAL IN INTERLOCK WTH Version 3.08.20 6 1 7 GENERAL ELECTRICAL NOTES A. INSTALL CONCEALED CONDUIT WITH FLUSH J.B.'S IN WALLS AND CEILINGS UNLESS NOTED OTHERWISE. IN FINISHED AREAS WITH INACCESSIBLE WALLS OR CEILINGS, PROVIDE SURFACE (WIREMOLD) RACEWAY, PAINT TO MATCH COLOR OF ADJACENT WALL OR CEILING. B. RACEWAYS SHALL CONTAIN A GROUNDING CONDUCTOR. C. CIRCUITS SUPPLYING LINE TO NEUTRAL LOADS SHALL HAVE DEDICATED NEUTRALS, i.e. ONE NEUTRAL PER PHASE. NEUTRAL CONDUCTORS SHALL HAVE TRACER STRIPE ALONG ENTIRE LENGTH INDICATING ASSOCIATED PHASE. D. BUILDING CONDUCTORS SHALL BE THWN/THHN. CONDUCTORS IN UNDERGROUND CONDUIT OUTSIDE OF BUILDINGS SHALL BE XHHW. E. NUMBERS AT RECEPTACLES AND LIGHT FIXTURES CORRESPOND DIRECTLY WITH PANELBOARD CIRCUIT NUMBERS AS SCHEDULED. BRANCH CIRCUIT WIRING AND HOMERUNS ARE NOT SHOWN FOR CLARITY. ACCURATE RECORD DRAWING INFORMATION IS TO BE PROVIDED AT THE PROJECT COMPLETION. TYPICAL THROUGHOUT. REFER TO SPECIFICATIONS FOR MATERIALS AND INSTALLATION REQUIREMENTS. F. REFER TO CONTRACT DOCUMENTS FOR SEQUENCE OF CONSTRUCTION AND PHASING OF THE CONTRACT. G. SWITCHES SHALL BE MOUNTED PER ADA REQUIREMENTS, 46" AFF. UNLESS OTHERWISE NOTED, RECEPTACLES AND TELECOMMUNICATION OUTLETS IN FINISHED AREAS SHALL BE MOUNTED 18" AFF. RECEPTACLES IN UN- FINISHED SPACES SHALL BE MOUNTED AT 46" OR 4" ABOVE WORK SURFACE. COORDINATE RECEPTACLE MOUNTING HEIGHTS WITH MILLWORK LOCATIONS, ARCHITECTURAL ELEVATIONS, AND MASONRY COURSING. H. CRITICAL DEVICES/ EQUIPMENT, INCLUDING TELEPHONE, COMPUTER, SECURITY, AND FIRE ALARM, AFFECT ASSOCIATED SYSTEMS BUILDING - WIDE. THESE SYSTEMS MUST REMAIN OPERATIONAL DURING THE CONSTRUCTION. INDIVIDUAL DEVICES MAY BE DISCONNECTED AND/OR RECONNECTED DURING CONSTRUCTION. COORDINATE POWER OUTAGES WITH OWNER. PROVIDE TEMPORARY PANEL(S) AND/OR CIRCUIT(S) AS/IF NECESSARY TO MAINTAIN CONTINUITY. PROTECT FROM PHYSICAL AND DUST DAMAGE. I. THE BUILDING SHALL MAINTAIN POWER THROUGHOUT THE CONSTRUCTION PROCESS. COORDINATE ENERGIZATION OF NEW EQUIPMENT AND THE CORRESPONDING RECONNECTION OF EXISTING AFFECTED ELECTRICAL DISTRIBUTION EQUIPMENT. J. SEE RELATED PLUMBING AND HVAC DRAWINGS FOR LOCATION OF EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. COORDINATE INTERCONNECTION REQUIREMENTS WITH EQUIPMENT SHOP DRAWINGS. K. WIRING FOR MISCELLANEOUS HVAC DEVICES AND CONTROLLERS SUCH AS DAMPER MOTORS, THERMOSTATS, DUCT SMOKE DETECTORS, FREEZESTATS, DIFFERENTIAL PRESSURE SWITCHES, OCCUPIED AND UNOCCUPIED SELECTOR SWITCHES, ALARM LIGHTS, ETC., NOT SHOWN ON ELECTRICAL DRAWINGS IS DIVISION 23 WORK. L. FIELD VERIFY EXISTING CONDITIONS. DISCREPANCIES BETWEEN THE DRAWING AND ACTUAL FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO BIDS. M. MAINTAIN EXISTING CIRCUIT CONTINUITY ON ALL SYSTEMS ON THE SITE THAT ARE EXISTING TO REMAIN. N. PROVIDE ALL CONDUIT HOMERUNS AS 3/4"C. MIN. O. COORDINATE ALL WORK WITH OTHER CONTRACTORS AND OWNER. P. ALL CUTTING AND PATCHING FOR DIV. 26 WORK SHALL BE UNDER SUPERVISION AND APPROVAL OF ARCHITECT. Q. REMOVE AND/OR REINSTALL ELECTRICAL DEVICES IN ALL AREAS OF WORK AS REQUIRED AND REPLACE ANY ELECTRICAL DEVICES DAMAGED BY WORK. NOT ALL DEVICES MAY BE SHOWN ON DRAWINGS. R. PROVIDE ALL BOXES, FITTINGS, CONDUIT, WIRING, TERMINATIONS, EQUIPMENT, ETC, FOR A COMPLETE INSTALLATION. S. BRANCH 20A CIRCUIT CONDUCTORS SHOULD BE SIZED AS FOLLOWS: 120V CCT LENGTH 277V CCT LENGTH AWG < 75' < 130' 12 75'- 120' 130'- 215' 10 120'- 200' 215' - 330' 8 8 ELECTRICAL DRAWINGS EO.00 ELECTRICAL SYMBOLS AND ABBREVIATIONS E1.10 STATION #2- MAIN LEVEL ELECTRICAL PLANS E1.20 STATION #2- RISER DIAGRAMS E2.10 STATION #16- MAIN LEVEL ELECTRICAL PLANS E2.20 STATION #16- RISER DIAGRAMS E3.10 STATION #17- MAIN LEVEL ELECTRICAL PLAN E3.20 STATION #17- RISER DIAGRAMS E4.00 ELECTRICAL DETAILS 0 W hea7,Qo. O 0 �pUing prns c PERMIT SET WEST METRO FIRE STATION GENERATORS WEST METRO FIRE 433 South Allison Parkway Lakewood, Colorado 80226 WOLD ARCHITECTS AND ENGINEERS 1553 Platte Street, Shiite 201 Denver, Colorado 80202 woldae.com 1 303 928 8800 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and mac I am a duly Licensed PROFESSIONAL ENGINEER underthe laws ofthe State of COLORADO License BRADLEY R.JOHANNSEN Number: 0047293 Date 8/20/2020 Revisions Comm: 205030 Date: 8/202020 Drawn : R. Hinks Check: B.Johannsen ELECTRICAL SYMBOLS AND ABBREVIATIONS Scale: As indicated E0.00 E A B 3 D E E 1 2 3 4 5 6 STATION #17 - MAIN LEVEL ELECTRICAL PLAN 1/8" = 1'-0" I � ) POWER KEYED SHEET NOTES I 1. PROVIDE CONCRETE PAD 4" ABOVE FINISHED GRADE. 2. PROVIDE BOLLARDS AROUND GENERATOR. 3. REFER TO MECHANICAL FOR TRENCHING AND PATCHING OF EXISTING PAVEMENT FOR NEW UNDERGROUND CONDUIT. CON DU IT TO MAINTAIN 5FT SEPARATION BETWEEN ELECTRICAL AND GAS LINES. 4. REFER TO MECHANICAL FOR REMOVAL AND REPLACEMENT EXISTING RETAINING WALLAS REQUIRED FOR INSTALLATION OF NEW CONDUIT. 5. REFER TO MECHANICAL FOR REMOVAL AND REPLACEMENT SECTION OF EXISTING CONCRETE LANDING AS REQUIRED FOR INSTALLATION OF NEW CONDUIT. 6. STUB LOCATION OF SPARE CONDUIT. REFER TO RISER. 7. PROVIDE CONCRETE PAD 4" ABOVE FINISHED GRADE. 8. DEMOLISH EXISTING GENERATOR AND DISCONNECT. 8 I POWER GENERAL SHEET NOTES I A. ALL LIGHTING AND POWER CONDUCTORS SHALL BE INSTALLED BETWEEN 24" (MINIMUM)AND 36" (MAXIMUM) BELOW FINISHED GRADE. B. ALL COMMUNICATIONS CONDUITAND CABLES SHALL BE INSTALLED 36" (MINIMUM) BELOW FINISHED GRADE. C. ALL CONDUCTORS FOR EXTERIOR LIGHTINGAND POWER CIRCUITS SHALL BE#10AWG MINIMUM. D. PROVIDE PVC -40 IN GREEN SPACESAND PVC -80 UNDER HARD SURFACES. E. PROVIDE PULL WIRE IN ALL EMPTY CONDUITS. F. PROVIDE DETECTABLE UNDERGROUND TAPE ABOVE EACH UNDERGROUND CONDUIT. G. HANDHOLES AND PULLBOXES MAYNOT BE INDICATED ON PLANS. PROVIDEAS REQUIRED FOR INSTALLATION. H. NO MULTI -BRANCH CIRCUITALLOWED. PROVIDE A SEPARATE NEUTRAL WITH EACH CIRCUIT. I. CIRCUIT WIRING IS NOTSHOWN EXCEPT FOR SWITCHING INTENT OF FIXTURES AND CONTROL OF DEVICES. J. GFCI RECEPTACLES SHALL BE WIRED TO PROTECT ONLYTHE DEVICES IN THAT OUTLET BOX. DOWNSTREAM DEVICES SHALL NOT BE PROTECTED BYGFCI. K. CIRCUIT NUMBERS SHOWN ARE FOR SCHEMATIC PURPOSES ANDARE FOR DISTINGUISHING CIRCUITS. RECORD AS -BUILT CIRCUITING IN A TYPED AND DATED PANELBOARD SCHEDULE. L. PROVIDE SEPARATED CONDUITS FORALL EMERGENCY CIRCUITS, DO NOT COMBINE WITH NORMAL BUILDING WIRING. of W heat v` R, A�7�rn9 DN`s�oc PERMIT SET WEST METRO FIRE STATION GENERATORS Station #17 10901 W 38th Ave, Wheat Ridge, CO 80033 WEST METRO FIRE 433 South Allison Parkway Lakewood, Colorado 80226 WOLD ARCHITECTS AND ENGINEERS 1553 Plane Street, Suite 201 Denver, Colorado 80202 woldae.com 1 303 928 8800 I hereby certify that his plan, specification or report was prepared by me or under my direct supervison and mac I am a duly Licensed PROFESSIONAL ENGINEER underthe laws ofthe State of COLORADO License BRADLEY R.JOHANNSEN Number: 0047293 Date 8/20/2020 Revisions T Comm: 205030 Date: 8/202020 Drawn: Author (1) Check: Checker North STATION #17 - MAIN LEVEL ELECTRICAL PLAN Scale: 1/8" =1'-0" E3.10 E A B C D E E 1 2 3 4 5 6 ROOF 205030 ROOF FEEDER 4W ID (NO NEUTRAL) (WTH NEUTRAL) (AMPS) CONDUIT -PHASE -GROUND CONDUIT -PHASE -GROUND 20A (1)112"C,3#12+1#12G (1)112"C,4#12+1#12G 30A UPPER LEVEL - - - - - - - - - - - - - - - - - - - - - I WIREWAY,1-PHASE,3-WIRE (1)1.25C, 3#4+1#8G WIREWAY,1-PHASE,3-WIRE 80A (1)1 25C, 3#3+1#8G (1)1.25C,4#3+1#8G 100A (1)1 25C, 3#3+1#8G (1)1.25C,4#3+1#8G 125A (1)15C,3#1+1#6G (1)15C,4#1+1#6G 150A (1)15C,3#110+1#6G (1)2"C,4#110+1#6G 175A (1)15C,3#210+1#6G (1)2"C,4#210+1#6G 200A (1)2"C,3#310+1#6G (1)2"C,4#310+1#6G 225A (1)2"C,3#410+1#4G UTILITY 250A UTILITY I i (1)25C,3#350+1#4G (1)TO4#350+1#4G 400A (2)2"C,3#310+1#2G (2)2"C,4#310+1#2G 500A (2)2 5C,3#250+1#2G (2)TO 4#250+1#2G CONNECTION CONNECTION (2)TO4#350+1#1G 800A 200A (3)2.5"C,4#300+1#110G 1000A 100A (3)3.5"C,4#400+1#210G 1200A 225A (4)TO 4#350+1#310G 1600A fi0A J -BOH J -BOH (6jC,3#400+1#250G AND METERING 2500A (7jC,3#500+1#300G (7)TO 4#500+1#300G 3000A (8)3.5"C,3#500+1#400G (8)3.5C,4#500+1#400G GENERAL NOTES. A. THE ABOVE FEEDER SCHEDULE IS A SCHEDULE OF TYPICAL FEEDERS AND SOME SIZES MAY NOT BE UTILIZED. B. ALL CONDUCTOR AMPACITIES ARE BASED ON TABLE 310-150F THE NEC FOR COPPER CONDUCTOR AT 75 DEG C. C. FEEDER SIZES SHOWN ON THE RISER DIAGRAM INDICATE FEEDER AMPACITIES AND DO NOT NECESSARILY CORRESPOND TO CIRCUIT BREAKER AMPACITIES. CERTAIN FEEDERS MAYBE SIZED FOR THE DURATION FACTORS REQUIRED BY CODE AND/OR ARE OVERSIZED FOR VOLTAGE DROP. D. WHERE PARALLEL CONDUITS ARE INDICATED FORA SINGLE FEEDER, EACH CONDUIT SHALL CONTAIN PHASE NEUTRAL AND GROUND CONDUCTORS INDICATED. E. CONDUIT ABOVE GRADE INDOORS SHALL BE EMT. CONDUIT ABOVE GRADE OUTDOORS SHALL BE GALVANIZED IMC OR RMC. F. EMT USED FOR PURPOSES OF SIZING CONDUIT. CONTRACTOR TO UPSIZE CONDUIT IF DIFFERENT THAN EMT. 3OAl2P CABINET CABINET 3 g ATS MAIN M PANELA PANEL LPC EM LPD 240/120V GEN PNL M 240/120V 240/120V 225A 240/120V 100A 240/120V 225A 240/120V 100A 225A 100A 225A 100A 8KW, 240V, 1 -PH MLO MLO MLO MLO i GENERATOR L___� 30A �� MLO MAIN LEVEL - - - - - - - - - - - EXISTING RISER DIAGRAM ST#17 N.T.S. 80KN 1201240V, 1 -PH GENERATOR 00 MAIN LEVEL - - - NEW RISER DIAGRAM ST#17 N.T.S. L J ---------- ------------------------------------------- ROOF - - - - - - - - - - - - - - - - - - - - -- 100A, 3W I MLO MLO MLO MLO O MLO O 7 8 GENERAL NOTES: A. PROVIDE COPPER CONDUCTORS. B. PROVIDE XHHW INSULATION FOR UNDERGROUND CONDUCTORS. C. PROVIDE GALVANIZED RIGID STEEL CONDUIT FOR EXPOSED EXTERIOR CONDUITS. D. ROUTE HORIZONTAL CONDUITS ABOVE BOTTOM CHORD OF BAR JOISTS UNLESS NOTED OTHERWISE. ROUTE CONDUITS FROM WALL MOUNTED DEVICES VERTICALLY TO JOIST SPACE UNLESS NOTED OTHERWISE. E. OBTAIN SHOP DRAWINGS OF EQUIPMENTAND COMPARE CONNECTION, LOAD, AND VOLTAGE INFORMATION TO CONTRACT DOCUMENTS BEFORE INSTALLING FEEDER CONDUITS. NOTIFYARCHITECT OF ANY DISCREPANCIES. BEFORE MAKING EQUIPMENT POWER CONNECTIONS, COMPARE EQUIPMENT NAMEPLATE DATATO SHOP DRAWINGS AND CONTRACT DOCUMENTS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. F. REFER TO PLANS FOR EXACT LOCATIONS OF EXTERIOR EQUIPMENT. G. COORDINATE ALL DEMOLITION WITH PHASING PLANS. SEE ELECTRICAL FLOOR PLANS AND ARCHITECTURAL PHASING PLANS. LINE TYPES: EXISTING EQUIP/FEEDER TO ff EX REMAIN r - DEMOLISH OR RELOCATE Ir 1'I RL EQUIP/FEEDER NEW OR NEW LOCATION OF �NL EQUIP/FEEDER uu KEYED NOTES: 1. PROVIDE CONCRETE PAD FOR GROUND -MOUNTED EQUIPMENT. 2. PROVIDE GENERAC SG080 GENERATOR (OR APPROVED EQUAL). GENERATOR TO HAVE STANDARD WEATHERPROOF ENCLOSURE. PROVIDE CAGE OVER MUFFLER TO PREVENT DEBRIS FROM ENTERING. 3. PROVIDE 1" CONDUIT WITH CONTROL WIRING FROM GENERATOR TO EACH ATS. COORDINATE EXACT REQUIREMENTS WITH ATS AND GENERATOR MANUFACTURER. 4. PROVIDE GENERAC RTSN400G3 SERIES OPEN TRANSITION SERVICE ENTRANCE RATED AUTOMATIC TRANSFER SWITCH (OR APPROVED EQUALS). WALL -MOUNT TRANSFER SWITCH TO BUILDING. 5. PROVIDE SURFACE -MOUNTED GENSET ANNUNCIATOR IN BUILDING, TO BE LOCATED BY OWNER. PROVIDE 1" CONDUIT WITH CONTROL WIRING. ASSUME A DISTANCE OF 150FT. 6. COORDINATE WITH UTILITY(XCEL ENERGY) FOR DEMOLITION/RELOCATION OF EXISTING UTILITY METER AND CONNECTION CABINET. 7. PROVIDE (1) SPARE 1.25" CONDUIT FOR FUTURE ATS. STUB CONDUIT INTO ELECTRICAL ROOM (SEE PLANS). 8. RENAME PANELBOARD EM TO "LPD (FORMERLY EM)". 9. RENAME PANELBOARD GENERATOR PANELBOARD TO "LPE (FORMERLY GENERATOR PANEL)". �0 NAheal lio C 011m B�7amo 3 PHASE FEEDERSCHEDULE(COPPER) 205030 ROOF FEEDER 4W ID (NO NEUTRAL) (WTH NEUTRAL) (AMPS) CONDUIT -PHASE -GROUND CONDUIT -PHASE -GROUND 20A (1)112"C,3#12+1#12G (1)112"C,4#12+1#12G 30A (1)314"C,3#10+1#10G UPPER LEVEL (1)314"C,3#8+1#10G (1)314"C,4#8+1#10G 50A (1)VC,3#6+1#10G (1)VC,4#6+1#10G 60A (1)1.25C, 3#4+1#8G WIREWAY,1-PHASE,3-WIRE 80A (1)1 25C, 3#3+1#8G (1)1.25C,4#3+1#8G 100A (1)1 25C, 3#3+1#8G (1)1.25C,4#3+1#8G 125A (1)15C,3#1+1#6G (1)15C,4#1+1#6G 150A (1)15C,3#110+1#6G (1)2"C,4#110+1#6G 175A (1)15C,3#210+1#6G (1)2"C,4#210+1#6G 200A (1)2"C,3#310+1#6G (1)2"C,4#310+1#6G 225A (1)2"C,3#410+1#4G UTILITY 250A (1)25C,3#250+1#4G (1)2.5C,4#250+1#4G 300A (1)25C,3#350+1#4G (1)TO4#350+1#4G 400A (2)2"C,3#310+1#2G (2)2"C,4#310+1#2G 500A (2)2 5C,3#250+1#2G (2)TO 4#250+1#2G CONNECTION (2)3u0,3#350+1#1G (2)TO4#350+1#1G 800A 200A (3)2.5"C,4#300+1#110G 1000A 100A (3)3.5"C,4#400+1#210G 1200A 225A (4)TO 4#350+1#310G 1600A 60A J -BOH 2000A (6jC,3#400+1#250G AND METERING 2500A (7jC,3#500+1#300G (7)TO 4#500+1#300G 3000A (8)3.5"C,3#500+1#400G (8)3.5C,4#500+1#400G GENERAL NOTES. A. THE ABOVE FEEDER SCHEDULE IS A SCHEDULE OF TYPICAL FEEDERS AND SOME SIZES MAY NOT BE UTILIZED. B. ALL CONDUCTOR AMPACITIES ARE BASED ON TABLE 310-150F THE NEC FOR COPPER CONDUCTOR AT 75 DEG C. C. FEEDER SIZES SHOWN ON THE RISER DIAGRAM INDICATE FEEDER AMPACITIES AND DO NOT NECESSARILY CORRESPOND TO CIRCUIT BREAKER AMPACITIES. CERTAIN FEEDERS MAYBE SIZED FOR THE DURATION FACTORS REQUIRED BY CODE AND/OR ARE OVERSIZED FOR VOLTAGE DROP. D. WHERE PARALLEL CONDUITS ARE INDICATED FORA SINGLE FEEDER, EACH CONDUIT SHALL CONTAIN PHASE NEUTRAL AND GROUND CONDUCTORS INDICATED. E. CONDUIT ABOVE GRADE INDOORS SHALL BE EMT. CONDUIT ABOVE GRADE OUTDOORS SHALL BE GALVANIZED IMC OR RMC. F. EMT USED FOR PURPOSES OF SIZING CONDUIT. CONTRACTOR TO UPSIZE CONDUIT IF DIFFERENT THAN EMT. 30Al2P CABINET 3 g ATS MAIN M PANELA 240/120V PANEL B 240/120V LPC 240/120V LPD 240/120V LPE [240/120V 240120V 225A 100A 225A 100A 100A, 3W I MLO MLO MLO MLO O MLO O 7 8 GENERAL NOTES: A. PROVIDE COPPER CONDUCTORS. B. PROVIDE XHHW INSULATION FOR UNDERGROUND CONDUCTORS. C. PROVIDE GALVANIZED RIGID STEEL CONDUIT FOR EXPOSED EXTERIOR CONDUITS. D. ROUTE HORIZONTAL CONDUITS ABOVE BOTTOM CHORD OF BAR JOISTS UNLESS NOTED OTHERWISE. ROUTE CONDUITS FROM WALL MOUNTED DEVICES VERTICALLY TO JOIST SPACE UNLESS NOTED OTHERWISE. E. OBTAIN SHOP DRAWINGS OF EQUIPMENTAND COMPARE CONNECTION, LOAD, AND VOLTAGE INFORMATION TO CONTRACT DOCUMENTS BEFORE INSTALLING FEEDER CONDUITS. NOTIFYARCHITECT OF ANY DISCREPANCIES. BEFORE MAKING EQUIPMENT POWER CONNECTIONS, COMPARE EQUIPMENT NAMEPLATE DATATO SHOP DRAWINGS AND CONTRACT DOCUMENTS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. F. REFER TO PLANS FOR EXACT LOCATIONS OF EXTERIOR EQUIPMENT. G. COORDINATE ALL DEMOLITION WITH PHASING PLANS. SEE ELECTRICAL FLOOR PLANS AND ARCHITECTURAL PHASING PLANS. LINE TYPES: EXISTING EQUIP/FEEDER TO ff EX REMAIN r - DEMOLISH OR RELOCATE Ir 1'I RL EQUIP/FEEDER NEW OR NEW LOCATION OF �NL EQUIP/FEEDER uu KEYED NOTES: 1. PROVIDE CONCRETE PAD FOR GROUND -MOUNTED EQUIPMENT. 2. PROVIDE GENERAC SG080 GENERATOR (OR APPROVED EQUAL). GENERATOR TO HAVE STANDARD WEATHERPROOF ENCLOSURE. PROVIDE CAGE OVER MUFFLER TO PREVENT DEBRIS FROM ENTERING. 3. PROVIDE 1" CONDUIT WITH CONTROL WIRING FROM GENERATOR TO EACH ATS. COORDINATE EXACT REQUIREMENTS WITH ATS AND GENERATOR MANUFACTURER. 4. PROVIDE GENERAC RTSN400G3 SERIES OPEN TRANSITION SERVICE ENTRANCE RATED AUTOMATIC TRANSFER SWITCH (OR APPROVED EQUALS). WALL -MOUNT TRANSFER SWITCH TO BUILDING. 5. PROVIDE SURFACE -MOUNTED GENSET ANNUNCIATOR IN BUILDING, TO BE LOCATED BY OWNER. PROVIDE 1" CONDUIT WITH CONTROL WIRING. ASSUME A DISTANCE OF 150FT. 6. COORDINATE WITH UTILITY(XCEL ENERGY) FOR DEMOLITION/RELOCATION OF EXISTING UTILITY METER AND CONNECTION CABINET. 7. PROVIDE (1) SPARE 1.25" CONDUIT FOR FUTURE ATS. STUB CONDUIT INTO ELECTRICAL ROOM (SEE PLANS). 8. RENAME PANELBOARD EM TO "LPD (FORMERLY EM)". 9. RENAME PANELBOARD GENERATOR PANELBOARD TO "LPE (FORMERLY GENERATOR PANEL)". �0 NAheal lio C 011m B�7amo 3 PHASE FEEDERSCHEDULE(COPPER) 205030 FEEDER 3W FEEDER 4W ID (NO NEUTRAL) (WTH NEUTRAL) (AMPS) CONDUIT -PHASE -GROUND CONDUIT -PHASE -GROUND 20A (1)112"C,3#12+1#12G (1)112"C,4#12+1#12G 30A (1)314"C,3#10+1#10G (1)314"C,4#10+1#10G 40A (1)314"C,3#8+1#10G (1)314"C,4#8+1#10G 50A (1)VC,3#6+1#10G (1)VC,4#6+1#10G 60A (1)1.25C, 3#4+1#8G (1)1.25C, 4#4+1#8G 80A (1)1 25C, 3#3+1#8G (1)1.25C,4#3+1#8G 100A (1)1 25C, 3#3+1#8G (1)1.25C,4#3+1#8G 125A (1)15C,3#1+1#6G (1)15C,4#1+1#6G 150A (1)15C,3#110+1#6G (1)2"C,4#110+1#6G 175A (1)15C,3#210+1#6G (1)2"C,4#210+1#6G 200A (1)2"C,3#310+1#6G (1)2"C,4#310+1#6G 225A (1)2"C,3#410+1#4G (1)2.5C,4#410+1#4G 250A (1)25C,3#250+1#4G (1)2.5C,4#250+1#4G 300A (1)25C,3#350+1#4G (1)TO4#350+1#4G 400A (2)2"C,3#310+1#2G (2)2"C,4#310+1#2G 500A (2)2 5C,3#250+1#2G (2)TO 4#250+1#2G 600A (2)3u0,3#350+1#1G (2)TO4#350+1#1G 800A (3)2.5C,3#300+1#110G (3)2.5"C,4#300+1#110G 1000A (3jC,3#400+1#210G (3)3.5"C,4#400+1#210G 1200A (4jC,3#350+1#310G (4)TO 4#350+1#310G 1600A (5)TC, 3#400+1#410G (5)3.5"C,4#400+1#410G 2000A (6jC,3#400+1#250G (6)TO 4#400+1#250G 2500A (7jC,3#500+1#300G (7)TO 4#500+1#300G 3000A (8)3.5"C,3#500+1#400G (8)3.5C,4#500+1#400G GENERAL NOTES. A. THE ABOVE FEEDER SCHEDULE IS A SCHEDULE OF TYPICAL FEEDERS AND SOME SIZES MAY NOT BE UTILIZED. B. ALL CONDUCTOR AMPACITIES ARE BASED ON TABLE 310-150F THE NEC FOR COPPER CONDUCTOR AT 75 DEG C. C. FEEDER SIZES SHOWN ON THE RISER DIAGRAM INDICATE FEEDER AMPACITIES AND DO NOT NECESSARILY CORRESPOND TO CIRCUIT BREAKER AMPACITIES. CERTAIN FEEDERS MAYBE SIZED FOR THE DURATION FACTORS REQUIRED BY CODE AND/OR ARE OVERSIZED FOR VOLTAGE DROP. D. WHERE PARALLEL CONDUITS ARE INDICATED FORA SINGLE FEEDER, EACH CONDUIT SHALL CONTAIN PHASE NEUTRAL AND GROUND CONDUCTORS INDICATED. E. CONDUIT ABOVE GRADE INDOORS SHALL BE EMT. CONDUIT ABOVE GRADE OUTDOORS SHALL BE GALVANIZED IMC OR RMC. F. EMT USED FOR PURPOSES OF SIZING CONDUIT. CONTRACTOR TO UPSIZE CONDUIT IF DIFFERENT THAN EMT. WEST METRO FIRE STATION GENERATORS Station #17 10901 W 38th Ave, Wheat Ridge, CO 80033 WEST METRO FIRE 433 South Allison Parkway Lakewood, Colorado 80226 WOLD ARCHITECTS AND ENGINEERS 1553 Plane Street, Suite 201 Denver, Colorado 80202 woldae.com 1 303 928 8800 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and mac I am a duly Licensed PROFESSIONAL ENGINEER underthe laws ofthe State of COLORADO License BRADLEY R.JOHANNSEN Number: 0047293 Date 8/20/2020 Revisions Dart Comm: 205030 Date: 8/202020 Drawn: Author Check: Checker STATION #17 - RISER DIAGRAMS Scale: As indicated PERMIT SET tj.1U A B C D F E 1 2 3 4 5 6 7 8 To UTII NEUTR NON SEPARATELY DERIVED GENERATOR AND 3POLE ATS(S). Ok MN heat v R� 0 �pUing prns c GROUNDING AND BONDING TABLE LEAD No O DESCRIPTION SZE TYPE REMARKS 1 GROUNDING ELECTRODE CONDUCTOR PER NEC 250661fABLE 25066 BAREORINSUL COPPER 2 GROUNDING ELECTRODE CONDUCTOR, CONNECTTOROD, PIPE, ORPLATEELECTRODE PER NEC 25066(R3 AWG) FARE COPPER 3 CONCRETE ENCASED ELECTRODE PER NEC 250 66 AWG) FARE COPPER d MA N BONDING JUMPER PER NEC 2502ETABLE 250.102(C)(1) FARE COPPER 41 SYSTEM BONDI NO JUMPER PER NEC 2502ETABLE 250.102(C)(1) FARE COPPER db SUPPLY DE BONDING JUMPER PER NEC 2502ETABLE 25030 I RAI TATED COPPER 5 EQUIPMENT BONDI NO JUMPER PER NEC 250.102 FARE COPPER 6 EQUIPMENT GROUNDING CONDUCTOR PER NEC 250.122JTAEH 250.122 INSULATED COPPER 7 GROUNDED SERVICE CONDUCTOR(NEUTRAL) SEE RI SER DIAGRAM INSULATED COPPER 8 COMMUNI CATION ROOM TELECOM BONDI NO BACKBONE PER ANSMA601-C(MNREAWG) INSULATED COPPER SEE TELECOMMUNICATON GROUNDING DETA LS FOR MORE INFORMAL] ON. 0 COMMON GROUNDING ELECTRODE CONDUCTOR PERNEC250.30(MINR3AWG) INSULATEDCOPPER NOTES 1. SEE DEAL SHEETS FOR ADDITONALINFORMATON ON GROUND BUSSES. GROUNDING DETAIL NTS "7VVC-HOLE NSULATOR WALL MOUNTING BRACKET 0 0 TIN PLATED COPPER GROUND BAR. 114" THICKX4'TALLX 24"LONG, HOLE CENTERS TO MATCH NEMADOUBLE LUG 0 CONFIGURATION 7VVO-HOLE CRIMP TYPE CONNECTORS SIZED AS REQUIRED TO FIT GROUND ABLES NOTES. 1. PROVIDE EXOTHERMIC WELD CONNECTIONS AND BOLTED LUG CONNECTIONS AS PER SPECIFICATIONS. 2. REFER TO TELECOMMUNICATION GROUND BUS DETAIL FOR REQUIREMENTS IN TELECOMMUNICATION ROOMS. GROUNDBUS PERMIT SET WEST METRO FIRE STATION GENERATORS WEST METRO FIRE 433 South Allison Parkway Lakewood, Colorado 80226 WOLD ARCHITECTS AND ENGINEERS 1553 Platte Street, Shiite 201 Denver, Colorado 80202 vea dae.com 1 303 928 8800 I hereby certify that his plan, specification or report was prepared by me or under my direct supervision and mac I am a duly Licensed PROFESSIONAL ENGINEER underthe laws ofthe State of COLORADO License BRADLEY R.JOHANNSEN Number: 0047293 Date 8/20/2021 Revisions Dart Comm: 205030 Date: 8/202020 Drawn: -R. Hinks Check: B.Johannsen ELECTRICAL DETAILS Scale: N.T.S. E4.00 From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: Commercial Interior Remodel/Tenant Finish Date: Monday, March 29, 20213:30:48 PM Commercial Interior Remodel/Tenant Finish Application for Commercial Remodel/Tenant Finish This application is for Commercial Remodels and Tenant Finishes. Do not being work until the permit has been issued to the General Contractor. Required to Submit Proof of Submission to Fire Department Proof of Submission to Fire Department Begin Application Fire Alarm Permit Application -West Metro Fire Rescue 17.Ddf PROPERTY INFORMATION Property Address 10901 West 38th Avenue Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Chris Schleef r`z�aY�dzc>.�c� Property Owner Email cschleef@westmetrofire.org Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Electronic Payment Form.odf APPLICANT INFORMATION Contact Name of Daniel Moore Person Submitting Application What is your role in the Architect project? Contact Phone Number (enter WITH dashes, eg 303-123-4567) Contact Email Address for Plan Review Questions 720-666-1970 dmoore@gentechus.com Retype Contact Email dmoore@gentechus.com Address DESCRIPTION OF WORK Is this for a new No tenant? Business Name of West Metro Fire Rescue Tenant Detailed Scope of Work - Provide a detailed description of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc Iii .i . STiTtamr, Square Footage Area of Work Being Performed Asbestos Report - if applicable Upgrade Gas Service to Replace existing 8MN 240V 1 PH Generator with 90kW natural gas 240V 1 PH Generator and 400A Service Entrance Rated 240V 2 Pole Transfer Switch. Concrete Work for trenching from existing service to new generator location in parking lot. Bollard install for generator protection per code. Back Parking Lot 2500 Field not completed. Construction Plans Field not completed. scanned on 11'x17" or larger Project Value (contract 79170 Valuation OK value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Daniel Moore Permit Email not displaying correctly? View it in your browser. City of Wheat Psj�dge COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Mechanical Subcontractor This form must be completed & signed by the MECHANICAL SUBCONTRACTOR performing mechanical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: (] C(U . 41 p -V v' General Contractor: FORM WILL NOT BE ACCEPTED WITH MISSING INFORMATION Company Name: �aS 66M�Y�-eOr-Contact Phone #: �� / �� Y� Wheat Ridge Contractor License #:� 9 Y� (required field) Sir Printed Name of Author' d Agent 5r-2o?0 21 Date 4'� City of '� Wheatjdge COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Electrical Subcontractor This form must be completed & signed by the ELECTRICAL SUBCONTRACTOR performing electrical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 10901 West 38th Avenue Wheat Ridge, CO 80226 Gen -Tech of Colorado General Contractor: Company Name: Faraday Electric, LLC Contact Phone#: (720) 636-6851 Wheat Ridge Contractor License #:_21_01 _19(required field) State License #: EC.101752 Master License#: ME.3000394 Liam Neet Printed Name of Authorized Agent oamune�nmmx® Liam Neet=, I -Nd -°'°.111.M 5/27/2021 Signature of Authorized Agent Date West Metro Fre Protection District /���r 433 5 Allison Fkwy. \i`.e J'AM Phonewe na.094307 wwwsa �rn ee.am West Metro Fire aucw Fire Alarm Permit Application F West Minn En Building or Tenant permitbe approved. issued and paid . eRaPROR to rewms_ m any required defamed submittal renews for that proteans "Mfidd work of any kind Al be alowea without an approved permit and staneea plan, on its. Work performed without a permt mar be asesed an additional fewer 0 APPLICANT INFORMATION CompanyName Gen -Tech of Colorado on: Daniel Moore Primeadwarrecolearrant, West Metro Fire Rescue#17 Perfect Address 10901 West 38th Avenue good Wheat Ridge Stake: Co ZIPCode: 80226 Phone 7206661970 En,ml dirrooreEgfitoentechus coin DesinProfessional:RyanHinds- Wold Engineering and Archuted Phone 6512277773 Emad: chinks woldae. corn PROJECT INFORMATION (CHEER ALL mAr APPt) 10 Occupancy oasnRration(,): — —10- reenc Building : MaBuilding Bulldi g orWork: pMoaRyo Replacement anal Replament O Removal Decommission Design tanaasa(,): ED 2009 IFC0 2 0 2007 M Description or Work/scope or Work: Replace existing 8kW 240V 1 PH Gen stator with 90 Read natural gas 240V 1 PH G enerate r Square footage of the protea: 2500 o Exported Reveal Request ($240.00 fee) o small Protect Remew Request ($112.50 fee) meet qualifications forthis renew tape G Choy, HERE to new fee Expedite Renew apparent aetaling these renew, Hopes Check fee box to confirm You've sad the mformawn. DE (NOT AN ALL INCLUSIVE LIST) Is ®Constructionplan,ana ancum n[ssnalmeM mdpmta rota of zualaen[tlatlNminalem Ma meson, nature and aJantnEMa loomashow maatao midplane with be applicable mea,, nanaa,a, dna amendments 0 0 Electronic Plans to Scale anmpan ams coma w��ncerort � Mongoose in Fi.u,r, spaces win theory, number date .I sh Full & proper mea analr,l, 0 Wagon Scope of Work 0 Equipment Data fim6 p 1, the applicatsverifytnat plans have been fully unlocked and unsecured at Me ti� of plan submittal. IGNING IFY THAT. are thoroughly .r�a andunderstandall fofo.matun an this Permp Appheatinn dna that all information a,ppbm i, e and mare m fee bat of my knowledge understand that Construction Plans and [Documents shall be conpmmam lece and nE t clarity id indicate feConstructionConstructioncation, nature and extent J the work proposed and shows in aaaa compliance with the applicable codes amara, and arrenamenm EE this Iz not the case Are plans mar be rekaed and a re-mh iftal fee may be as,a,m. and approval by the Fire Eaae Dmaal shall not relieve the applicant of the responsibility of compliance with Review applicable coda, standard, and arren amen. Signature ofAppRmntipaf10�MOOfO Digitally aignaa by Daniel Moore Date 202 m25Is:0nt2-Da00' Date: 03/29/2 Plan review commentsand sla Ws regarding projects are available by logging In to your contractor portal at w sew. mobil A eves cc m/PA Index.asD"i mirLoaon Feb 20 � ► 44" City of Wheat Ridge '/� Comm. Tenant Finish PERMIT - 202100584 PERMIT NO: 202100584 ISSUED: 06/10/2021 JOB ADDRESS: 10901 W 38th Ave EXPIRES: 06/10/2022 JOB DESCRIPTION: Generator Replacement - Upgrade Gas Service to Replace existing 8kW 240V 1PH Generator with 90kW natural gas 240V l PH Generator and 400A Service Entrance Rated 240V 2 Pole Transfer Switch. Concrete Work for trenching from existing service to new generator location in parking lot. Bollard install for generator protection per code. Back Parking Lot *** CONTACTS *** OWNER ( 7 2 0) 641-2353 WHEAT RIDGE FIRE PROTECTION DI SUB (303)466-4206 AMY MCKEE 017986 THE GAS CONNECTION SUB (720)636-6851 LIAM NEST 210119 FARADAY ELECTRIC, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 700 / Support Buildings BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 79,170.00 FEES Total Valuation 0.00 Plan Review Fee 631.18 Use Tax 11662.57 Permit Fee 971.05 ** TOTAL ** 31264.80 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IBC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. City of Wheat Ridge Comm. Tenant Finish PERMIT - 202100584 PERMIT NO: 202100584 JOB ADDRESS: 10901 W 38th Ave JOB DESCRIPTION: Generator Replacement - Upgrade Gas 1PH Generator with 90kW natural gas Entrance Rated 240V 2 Pole Transfer ISSUED: 06/10/2021 EXPIRES: 06/10/2022 Service to Replace existing 8kW 240V 240V l PH Generator and 400A Service Switch. Concrete Work for trenching from existing service to new generator location in parking lot. Bollard install for generator protection per code. Back Parking Lot I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this,permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/10/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. � ► 44" City of Wheat Ridge '/� Comm. Tenant Finish PERMIT - 202100584 PERMIT NO: 202100584 ISSUED: 06/10/2021 JOB ADDRESS: 10901 W 38th Ave EXPIRES: 06/10/2022 JOB DESCRIPTION: Generator Replacement - Upgrade Gas Service to Replace existing 8kW 240V 1PH Generator with 90kW natural gas 240V l PH Generator and 400A Service Entrance Rated 240V 2 Pole Transfer Switch. Concrete Work for trenching from existing service to new generator location in parking lot. Bollard install for generator protection per code. Back Parking Lot *** CONTACTS *** OWNER ( 7 2 0) 641-2353 WHEAT RIDGE FIRE PROTECTION DI SUB (303)466-4206 AMY MCKEE 017986 THE GAS CONNECTION SUB (720)636-6851 LIAM NEST 210119 FARADAY ELECTRIC, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 700 / Support Buildings BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 79,170.00 FEES Total Valuation 0.00 Plan Review Fee 631.18 Use Tax 11662.57 Permit Fee 971.05 ** TOTAL ** 31264.80 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IBC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. City of Wheat Ridge Comm. Tenant Finish PERMIT - 202100584 PERMIT NO: 202100584 JOB ADDRESS: 10901 W 38th Ave JOB DESCRIPTION: Generator Replacement - Upgrade Gas 1PH Generator with 90kW natural gas Entrance Rated 240V 2 Pole Transfer ISSUED: 06/10/2021 EXPIRES: 06/10/2022 Service to Replace existing 8kW 240V 240V l PH Generator and 400A Service Switch. Concrete Work for trenching from existing service to new generator location in parking lot. Bollard install for generator protection per code. Back Parking Lot I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this,permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/10/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE [I,' e it to 1 Inspection Type: �� � S- - , �A 17) e c Job Address: 1 9 0 1 w 3 6 A we Permit Number: a o 1-7 0 C) a <; 9 ..s C- U r -C c1 a d - -PC r C -r C IF/1 l -t"6 ❑ No one available for inspection: Time 9 PM Re -Inspection required: Yes f When corrections have been made, call for re -inspection at 303-234- Date:- -0 Inspector: 7—h DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE -.A Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office * (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: IF -t e MCC, Job Address: La`` (A k � � CLLr, Permit Number: tl 0i^, e, VN C U No one available for inspection: Time AM/PM Re -Inspection required/Yes) No When corrections have been made, call for re -inspection at 303-234-593 Date:--' kj Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: © < <— Job Address: Permit Number: fie 1 ❑ No one available for inspection: Time' AM/PM Re -Inspection required: Yes No When corrections have been made, c, ll for ,e-inspecti 4=5933` Date: ( .- L'fi`— lit" Insaector`�,,/`- i. , CITY OF WHEAT RIDGE Building, Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Ef I: Job Address: M V Permit Number: I 0-1 'r LJ No one available for ijese tion: Time /I/PM Re -Inspection required: o When corrections have been made, c I r re -inspection at 303-234-5933 ,� Date: In spect - - DO NOT REM E THIS NOTICE I. i -CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION N.QTICE Inspection Type: Job Address: c)UD Permit Number: E ❑ No one available for inspection: Titer .% /C% AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 t Date: l �ilnspecto . DO NOT REMOVE THIS NOTICE i CITY OF'WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235=2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: k ,�,j Job Address: Permit Number: No one available for inspection: Timte--/AWPM Re -Inspection required: (�e, —"N o When corrections have been made, ca or re -inspection at 303-234-5933 Date: ttJ Inspector. -- } DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTIONNOTICE Inspection Type: 3 0 8- P E V C 0 1 ec< - Job Address: l o g o l Ly 3 a5 �-� A v -e Permit Number: a o 1-7 o g a S 9 ISS KD So L _ r s_; r� -t r, -c44 :2 e— � ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date. — L? Inspector: DO.NOT REMOV HIS NOTICE 1E' The City of Wheat Ridge Third Party Form Check List Property Address 387 ,02 Permit Number Permit Issued Date 2 O i1 �V Owner Information Property Owner Information eg�ro �c7i rr� C QLk _ Property Owner Address 133S , �`Son Ply w Y oa , C o g o Inspector Inf:)rmation Inspection Company Mtop-5 - per, Inspector Name 7 Inspector Contact info. 7V�9, Inspector Statement and Acknowledgement * I hearby acknowledge the roof I am inspecting is 6/12 or over all roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * I hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City PfV7Yat Ridge Policies and Procedure and Manufacturer's recommendatio icatic inspector: Date: / roperty Owner Statement of Acknowledgement *l hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat Rid e Bu g Di ' ' n inspection. Propery Owner/ Agent: Date: This original document as well as the roofing check list, must be submitted to the Chief Building Offical within seven days of the final inspection. Drop off in person Submit via Email Permit counter 2nd floor 7500 W. 29th Ave Wheat Ridge CO 80033 Drafted Date: 7/26/17 Please add note to reverse side The City of Wheat Ridge Inspection Check List notes Final Roof Roof Inspection Vass Fail I J 1 —1 Fail Structural roof components [J Fail Verify that no more than 2 layers of shingles exist Frail Flashing -for roof and walls [_111 Fail If new sheathing is installed verify that it is listed in tho permit description (Valuation must be adjusted) Fail Verify sheahing nail pattern ( See policy & Proceed ures,) Fail Crickets and saddles where needed Fail Verify B vent must have boot same gauge as pipe J_ --_I rail Verify vent caps [-] 1:ail Verify no flashings are damaged or rusted P&I" Fail Step flashing shall be min. of 4x -e1. piece per shing1k, I'l—, I Fail Verify scuppers allow for proper drainage 1."V 1 Fail Ice and water shield 2' in heated wall spaces 1XII I -ail Underlayments must -follow 2012 IRC / 20,12 11,3C [_l Fail Verify roof slope for proper drainage -ail Dripedge shall have min of 2" overlap Al, Fail Dripedge should extend down min 2" past roof deck Fail Dripedge shall be mechanicaly fastened 12" OC *!'r.,,,;,,, 1I I I rilil 90 LB roll roofing shall not be applied to roof slopes, less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of .1 A 2 - J Fail Modified Bitumen, EPDM, TPO min slope, 1/4-12 slope Fail Above roof insulation R-25 17,lil Below roof residential R-38 Fail Below roof commercial R-32 rail Modified Bitumen, EPDM, TPO min slope 1/4.12 slope must be installed in accordance with the mAnLIf,'-1CtUFO-.I_S specifications- Must have manufactures letter of warranty with the address on the letter for final inspection K--�t,fl Roof ---------- Shirqcles Reauiremen-ts, I F;111 Metal roof shingles shall riot be installed on slope less 3. 12 I- i,'A -ail Metal valley -flashing shall be the same material as roof I evil Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile POofs. Reoluirements "A Clay and concrete tile shall have a r-nin- 2 -1/212 slope Slopes 4A2 and Linder require dOLjbl(-- uriderlaynient The City of Wheat Ridge Inspection Check List notes Final Roof Notes Company Name: Inspector signatu . ft—W., IT re: Date of Inspection:�rr.� _- iCITY OF WHEAT RIDGE �`' Building Inspection Division V-11 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 6AS /—lei-( Job Address: /090/ W 3?1:h 1Alr- Permit Number: ,,,20t-7C62aC1 ❑ No one available for inspection: TimeLPM Re -Inspection required: Yes�No� *When corrections have been made, call for re -inspection at 303-234-5933 Date: `x'40' 5� Inspector: d DO NOT REMOVE THIS NOTICE iIr-CITY OF WHEAT RIDGE �'(303) 19 Building Inspection Division (303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M lid Job Address: 1 C)9 ()I Li 1ST %-jQ- Permit Number: 20I 6 CO F 0 F flat u� ❑ No one available for inspection: Time awn M Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: '6`26, f Inspector: 0 DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _1�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F-1110 l 94.1--6 1/ Job Address: 1090 i GJ 38 eve Permit Number: ,s 01-IQ22 E2 CIV 70' 11z&amu, ❑ No one available for inspection: Time lav _ WPM Re -Inspection required .6�_ No When corrections have been made, call for reinspection at 303-234- m 5933 Date: 0.2o - f � Inspector: % C DO NOT REMOVE THIS NOTICE �_ CITY OF WHEAT RIDGE Building Inspection Division,`` (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax Inspection Type: INSPECTION NOTICE JobAddress: (C 1C1 (-' ( Uj 7,c3 fti e. Permit Number: 2 017a2248 ❑ No one available for inspection: Time _ AM/PM Re -Inspection required::`` Yes_ No When corrections have been made, call for re -inspection at 303-234-5933 Date: 1-7 ° 1 Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Commercial Roofing PERMIT - 201802248 PERMIT NO: 201802248 ISSUED: 08/13/2018 JOB ADDRESS: 10901 W 38th Ave EXPIRES: 08/13/2019 JOB DESCRIPTION: Commercial re -roof -Tear oof one layer of existing roof and install ice and water barrier at eave line, and replace with one layer of synthetic underlayment. replace with Atlas Pristine Pinnacle. Squares: 38.67; Pitch 6/12 *** CONTACTS *** OWNER (720)641-2353 WHEAT RIDGE FIRE PROTECTION DI SUB (303)360-0708 Curtis Boyd 017261 Academy Roofing, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 700 / Support Buildings BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 12,748.00 FEES Total Valuation 0.00 Use Tax 267.71 Permit Fee 251.85 ** TOTAL ** 519.56 *** COMMENTS *** *** CONDITIONS *** In order to pass a final inspection on commercial elastomeric or similar type roofing, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and Mid -roof inspections may be called in at the same time, 100 percent of the sheathing must be complete and 25-75 percent of the midroof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. I, by in signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thisermrt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be perform d nd that all work to be performed is disclosed in this document an /or its, ccompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying Flans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or Di. conceal work without written approval of such work from the Building and Inspection Services n. 6. T i an a or gra g of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any cabl ode or o nce or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY City of Wheat Ridge _r_ Commercial Roofing PERMIT - 201802248 PERMIT NO: 201802248 ISSUED: 08/13/2018 JOB ADDRESS: 10901 W 38th Ave EXPIRES: 08/13/2019 JOB DESCRIPTION: Commercial re -roof -Tear oof one layer of existing roof and install ice and water barrier at eave line, and replace with one layer of synthetic underlayment. replace with Atlas Pristine Pinnacle. Squares: 38.67; Pitch 6/12 I, by in signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thisermrt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be perform d nd that all work to be performed is disclosed in this document an /or its, ccompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying Flans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or Di. conceal work without written approval of such work from the Building and Inspection Services n. 6. T i an a or gra g of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any cabl ode or o nce or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY City of WheatN COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29t1 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(o)ci.wheatridge.co.us /IZC �'a6Y Z I FOR OFFICE USE ONLY Date: Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: I PN W . 2� ANE. Property Owner (please print): &� Mekro FIT, V_ff.QC�p— Phone: O aon Property Owner Email: Tenant (Commercial Projects Only) yJe5 ►v e7 ` c) Flylt Property Owner Mailing Address: (if different than property address) Address: Architect/Engineer E-mail: Contractor: City of Wheat Ridge License #: Contractor E-mail Phone: For Plan Review Questions & Comments' (please print): CONTACT NAME (please print): PAM Phone:�� CONTACT EMAIL(please print): Sub Contractors (Must provide Wheat Ridge License No.): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # N COMMERCIAL ❑ RESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Tfflx opf (1) La�ey o� Mi ;' hen y ooh- ms -V i ae o'"d V oatty o��- w1 � maoA 1 co LNty o�- S n-Hneb& vndt. \a jrnent; Commercial Projects Only: Occupancy Type: Faygastruction Type: Sq. Ft./LF BTUs Amps Squares • 01 Gallons Project Value: (Contract value or the cost of all materials and labor included in the entire project) $10,1114�) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORJ7XD REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): C�y� / DATE: �p9 / Y Printed Name: L. Co / `'tWe-,— ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: City of Wheat Ridge Comm. Tenant Finish PERMIT - 201709289 PERMIT NO: 201709289 ISSUED: 06/15/2018 JOB ADDRESS: 10901 W 38th AVE EXPIRES: 06/15/2019 JOB DESCRIPTION: Comm. Tenant Finish - Remodel kitchen; Demo two non -load bearing walls; Add one demising wall; Relocate range and extending gas line *** CONTACTS *** OWNER (303)905-0665 WEST METRO FIRE GC (303)359-8337 Lance Nading 170675 C3 Construction Services SUB (303)720-5345 Adam Stockton 170035 Exceed Electrical Contracting SUB (303)233-7007 Torrey Cosgrove 017885 Lakewood Plumbing LLC SUB (303)233-7007 Torrey Cosgrove 017885 Lakewood Plumbing LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 700 / Support Buildings BLOCK/LOT#: 0 J *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 24,000.00 FEES Total Valuation 0.00 Plan Review Fee 277.03 Use Tax 504.00 Permit Fee 426.20 ** TOTAL ** 1,207.23 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. City of Wheat Ridge Comm. Tenant Finish PERMIT - 201709289 PERMIT NO: 201709289 ISSUED: 06/15/2018 JOB ADDRESS: 10901 W 38th AVE EXPIRES: 06/15/2019 JOB DESCRIPTION: Comm. Tenant Finish - Remodel kitchen; Demo two non -load bearing walls; Add one demising wall; Relocate range and extending gas line I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this,�ppermrt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be eri pormedaand that all wo k to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signa(ure of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and� �pprocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not roceed or conceal work without written approval of such work from the Building and Inspection Services Divisio 6. The is a e o grantin . a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any apple cod or any a or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wh6, atj�idge COMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. This form will not be accepted with missing information. Project Address: General Contractor: Electrical Sub -Contractor Permit #: Company Name:Exceed Electrical ContractingPhone #: 303-720-3678 State License #: EC.0100895 Master #: ME.0600711 Wheat Ridge License #: 170035 (required field) gakel, 6/5/2018 Signature of Authorized Agent Date Company Name: Phone #: State License #: Master #: Wheat Ridge License #: (required field) Signature of Authorized Agent Mechanical Contractor Company Name: Date Phone: Wheat Ridge License #: (required field) Signature of Authorized Agent Date Mr. Brian Tardif City of Wheat Ridge CURRENT ENGINEERING A Member of the Current Design Group VIA Email: btardif@ci.wheatridge.co.us Dear Brian: 1439 Court Place Denver, CO 80202 Phone: (303) 810-0800 Email: info@4current.com April 26, 2018 Re: Project: West Metro Fire Station #17 /Remodel Project Address: 10901 West 38th Avenue, Wheat Ridge, CO We reviewed the plans for the above captioned remodel. The specifications for the kitchen stove and hood are attached. Please be advised that no makeup air is required for this equipment. We have confirmed this information with your consultant on the mechanical plan review. Thank you for taking the time to review this project. Please contact me at your convenience with any questions or concerns. Sincerely CURRE Tom Sch Tom Schirmer, PE Principal (720)891-7720 UP MEP Engineering Power for the People www.4current.com Z JENN-AIR- L; L 11 r> d Pro -Style@ Gas Range with Griddle and MultiMode@ Convection, 48" Model # JGRP548VVP t F 4.4 out of 5 (12 Reviews) ' Call for Our Best Price QtyKI 303-789-9945; - Note: Due to manufacturer police, this product cannot be added to your cart. Contact BAC Appliance Center for nrore details. Overview Specifications Rebates Warranty Delivery Help Reviews This large commercial -style Jenn-Air& Pro-Stylee) gas range offers exceptional versatility Two 20,000 BTU stacked burners give you the power for high -heat cooking and the precision for gentle simmering, while the high-performance, chrome -finish griddle delivers even heat. And six different convection cooking modes like bake; roastand broil distribute heat evenly and thoroughly; for beautifully consistent results Specifications Configuration and Overview • Fuel Type: Gas Range Type : Freestanding 48" Siena Pro Island Model # ZSLE48BS Call for Our Best Price Qty 303-789-9945 =:""77 Overview Specifications Warranty Delivery Help With its classic, professional -style design Siena Pro island manages to encompass a wealth of features perfect for the culinary pro or any aspiring home chef. Now with magenfic duct covers: the unique Quick -Lock installation system is easier than ever. Equipped with a 1200-CFfvl blower, BriteStripT" LED lighting, and ACT" technology. West Metro Fire Rescue November 16`x„ 2017 West Metro Fire Rescue has reviewed and accepts the plan drawing provided by the Contractor, Haystack Construction for the following remodel project at West Metro Fire Rescue Station 17 at 10901 W. 38th Avenue, Wheat Ridge, Co. 80033 Any deviation from plan design must be submitted in writing and approved prior to implementation. Contractors is responsible for verifying all measurements, Permits, Utilities locates, Debris removal, Ground remediation and clean up. )4" � A - C r Lt. Pat Mulligan West Metro Fire Station 17 10901 W. 38th Ave Wheat Ridge, Co. 80033 303-905-0665 A/V CARPET / 10'-0" CLG. J a KITCHEN NEW LVT / 1a-g*CLG. HALL Ve>s /.r 0,-0.. CLG. /� r+Ew w.0 _ w�.Eooeeoe.we cows« xousHe ewrnnuiro ceee REFRIG - BOARD ROOM BUNKER ROOM - IsswFr NEW VINYL PLANK / 10'-0" CLG. CARPET / 10'-0" CLG. REFRIG „000 awe e.r.or: C -SHIFT 'oreu..o REF��IG. �� eve �� oceoerirrvecowrm rto�ee.e ews weroer,HeE MAIN LEVEL PLAN - NEW CONSTRUCTION SCALE: 11,C= V -a' asat n MAIN LEVEL PLAN - NEW ELECTRICAL Vjh9aRld0 J SCALE: 1/4"= F -Y' &AI&V DOW r- Z w O Qw M Lu H-wo a N > 00 0wire = 0 Lu � � u M ? m: H 0 O�� U ~ W w LLJ W 3 O U F - 2W MAIN LEVEL PLAN - DEMO & NEW me nfomwrim,nown mmn donxnent reprosents copyrighted rota- d properly. Reproduefion md/oi outbufim is not pemJffed without fhe prior coroent of lodesime Design Gffrwp. u o� ops o� �a ooh d e; • E ; R 3 1� O V • •O V vJ nW 1-� Dl.l ,(-------RAMP ANCARPET 10'-0" CLG. Lj L=: HALL VCT / 10'-0" CLG. I I .--c.e.a..,a.eo eooMro www I II I II I II `—.ao.,,u<aMubd�o,arEo BOARD ROOM I .moo. u: e.oa..c�eraro.eww—�{ I I CARPET / 10'-0"CLG. II III w.« BUNKER ROOM CARPET — I \,e.—eaoa MAIN LEVEL PLAN - DEMO II REFRIG. III �:+—e..ewur I D/w IL_ KITCHEN III /\\ II wE000K:w�.o..cwur IT lii'LL—' —e �I JIBVCT / 8'-0"CLG. �REFRIG.. J L eeMo „s -s ea r RANGE I I I JI 7L Hdf-switched 100 I �I I I .--c.e.a..,a.eo eooMro www I II I II I II `—.ao.,,u<aMubd�o,arEo BOARD ROOM I .moo. u: e.oa..c�eraro.eww—�{ I I CARPET / 10'-0"CLG. II III w.« BUNKER ROOM CARPET — I \,e.—eaoa MAIN LEVEL PLAN - DEMO 1 SCALE: 1/4" = 1'-0" ELECTRICALLEGEND Hdf-switched 100 phone jock ® 5" BWt-green certified seded drecti—I recessed can light fixture Switch Duplex power outlet Cat.5 data lack O Pendonl light fudure 5witoMihree way 220 power ouHet pared phone and Cat. Sdata jod ® Chandelier light (afore ® Ceiirg outlet 7,V. Ouilet wdl mounted light fixture Switch -tour way 9— outlet O Junction Box V "' V Track light ❑ Gtrsausl tan Switc"iirnmer Hose Bibb Celing mount 2 -lamp 4'-O® Eirr. st fan and light ryuorescent light fixture Duplex power outlet Gas —) -- ------- Under cabinet fixture Duplex power cutlet ,,F,y Motor / D'nposd }.l CeOmg mount light future + CeiNg Im mm A &tenor Waterproof G.F.C.I. m CK-. Balton (doo,bell) ® 5' Recessed Can Light Future LJ Duplex power outlet 11 SeMce panel Doorbell Chir". Doorbell ®W waterproof Recessed Under Counter G.F.C.I. i City of Wh6at COMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. This form will not be accepted with missing information. Project Address: Permit #: General Contractor: Electrical Sub -Contractor Company Name: Phone #• State License #• Master #• Wheat Ri #• (required field) liense Signator u of oriz ed Agent Date Plumbing Sub -Contractor Company Name: Lakewood Plumbing, LLC Phone #• 303-233-7007 State License #: PC.0001685 Master #: MP.00187294 Wheat Ridgy ,icense #: 017885 (required field) 615/18 Signature f u o ized Agent Date Mechanical Contractor Company Name: Lakewood Plumbing, LLC Phone: 303-233-7007 01788 Wheat Ridge License #:Wo (required field) 6/5/18 Signaturent Date COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/A PLIANCE RE AIR or REPLACEMENT [` OTHER (Describe) I!t (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) L -O, -A t$ .� W,. V6 %SAA Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ CJ 9 Go 0 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER)�(COor (CONTRACTOR) (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): DATE: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: '� S - b -4 1 / DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ City of Wheat �dge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(cDci.wheatridge.co.us Ca FOR OFFICE USE ONLY Date: �l� Plan/Permit # 2 Plan Review Fee Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Q ( I S n 5W-31 Property Owner (please print): LL c <i � (A,,,<-_ C_ {-�� �� Phone: ,3 clZ�S - [}r✓( Property Owner Email: 1Nt.0 JL n'o—, C� L � Mailing Address: (if different than property address) Address City, State, Zip: Arch itect/Engineer: S - 0'C_ Architect/Engineer E-mail: Phone: 3(o3 Vo C7 --gA `;- 3 Contractor: (::!-, '? C� 5 �x ..� S c� �.; LC_eS Contractors City License #: I In i 5" Phone: -7,20 ZY 3 Ll -- <5,:)/5�• Contractor E-mail Address: t1111_4z'�_ V%C-C%\ _,' 1,2 Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Certificate of Completion Building Division 7500 W 29TH AVE WHEAT RIDGE CO 80033-8001 Permit#:201500691 Issued: 08/12/2015 Stipulations: Modifications to Increase the Height of Two (2) Garage Doors. This certificate verifies that the building constructed and/or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code and development standards of the zone district in which it is located and may be occupied. All other licensing requirements for the City must be met. Owner: CITY OF WHEAT RIDGE 7500 W 29TH AVE WHEAT RIDGE CO 80033 Contractor: Wade Cumming 2 MOUNTAIN CEDAR LN LITTLETON CO 80127 For the Following Purpose: Commercial Remodel Co 'Editions NO change shall be made in the USE of ,�'e2012 ICC/2014 NEC this building without prior notice — 2006 ICC/2011 NEC and a new Certificate of Completion — 2006 ICC/2005 NEC from the City of Wheat Ridge. Other C Buy g Ira -,—tor Zoning —A-ai i Eni s t Tra t o �r� CE41FICATE MUST BE POSTED BY FRONT DOOR OF COMMERCIAL OCCUPANCIES Or Wheat Bj )MMUNiTy DEVELOPMENT Building & Inspection i « O 03-235-2855 1* • Inspection303-234-5933 Property Owner 1i�31dl1 piling Address: (if different than property address Address: Ci!y, State,, Zi Archit"VEngineer E-mail. Phone t contractor- ContractorsCity Ll 0: Phone.* Contractor E-mail Add s: Sub ontr t t Electrical: plumbing: Mechanical: VR City License # W.k City L icense # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License ## City License # Complete all information on BOTH sides sof this farm Mari M . . R .�► t"h VES ,G e! �r- I -two ki F ky Sq. FUL.F Btu's Gallons Amps Squares Other GS G rO * Pth Structuraf, LLc March 11, 2015 Wheat Ridge Fire Protection District Arm,: Mr. Kelly Brooks — Fire Marshal 3880 Upham Street Wheat Ridge, CO 80033 Griffeth Structural, LLC 8833 West 32' Place 'Wheat Ridge, CO 80033 Office: (303) 237-4346 Fax: (303) 237-4358 info @GriffethStructural,corn ,ww,A,.GriffetiiStructiti�al.coo RE: Framing Modifications at New Garage Doors at Center Truck Bay Wheat Ridge Fire Department — Station 2 10"I W. 381h Ave. — Wheat Ridge, CO 80033 (Jefferson County) Griffeth Structural, LLC (GS) is a small engineering company that specializes in the design and evaluation of residential & commercial structures. GS performed a site visit on August 15, 2014, and again on January 29, 2015, to observe existing conditions related to proposed construction of the above listed project. The following statements are based on our observations as well as information provided by you: I. New Garage Doors at Center Truck Bay a. It is structurally acceptable to modify the existing wall framing and existing soffit 41, framing located in the vicinity of the existing garage doors of the center truck bay in order to allow for the installation of new taller garage doors. The existing wall framing and existing soffit training shall be modified in accordance with the attached drawings (Detail A I — A.4). a. This evaluation does not include the design of temporary bracing and support of the roof framing and floor framing. It is assumed that the General Contractor will provide adequate temporary framing during construction as necessary. 3. Other Project Professionals -ned that the Owner-willaaaLly Griffeth Structural, LLC Z4"" 8833 Wesi 32" Place NNleat Ridge. CO 80033 SR Offim (303) 237-4346 Fax: (303) 237-4358 ritle info@Griffeth&nictural,com G th Stmauraf LLC CSE ��ww(jnff�etWj�rucqgaj corn architectural, civil, electrical, mechanical, environmental, and/or energy plans, issues, specifications, and designs. If you have any questions, comments, or concerns, please feel free contact us at any time at the above -listed phone number or email. Michael P. Griffeth, Prqfessianal Engineer President — Griffeth Structural, LLC GRID—LINE REPRESENTS INTERIOR GRID—LINE REPRESENTS INTERIOR FACE OF (E) CONCRETE -----__ lD (E) ROOF FRAMING HEADER TO FACE OF (E) CONCRETE----, G URI D (E) ROOF FRAMING HEADER TO MASONRY UNIT WALL (BEYOND) REMAIN (± 8" TALL STEEL MASONRY UNIT WALL (BEYOND) —REMAIN (± 8' TALL STEEL CHANNEL WITH 2x8 TIMBER CHANNEL WITH 2x8 TIMBER LEDGER & 2x4 TIMBER LEDGER) LEDGER & 2x4 TIMBER LEDGER) (E) 2x4 TIMBER TOP CHORD (E) 2x4 TIMBER TOP CHORD EXTENSION OF ROOF TRUSS EXTENSION OF ROOF TRUSS AT 24" O.C, TO REMAIN (E) ROOF SHEATHING AT 24" O.C. TO REMAIN (E) ROOF SHEATHING TO REMAIN TO REMAIN (E) 20 TIMBER (E) 2x4 TIMBER L STRUTS AT 24" O.C.______x (E) ROOF FRAMING (18' TALL (E) ROOF FRAMING (18' TALL STRUTS AT 24" O�C�---7� TO BE MODIFIED OPEN WEB TIMBER TRUSSES TO BE MODIFIED --OPEN WEB TIMBER TRUSSES AT 24- O.C,) TO REMAIN AT 24" O.C,) TO REMAIN SLOPE SLOPE (E) PLYWOOD & STUCCO EXTERIOR WALL TO REMAIN 3'— 2,V2 li SOFFIT & OVERHANG (E) PLYWOOD GUSSET Its AT 24" O.C. TO— BE MODIFIED (E) TIMBER WALL (20 STUDS AT 24- O.C,) TO BE MODIFIED (E) 20 TIMBER STRUTS AT 24" O.C. TO BE MODIFIED (E) PLYWOOD & STUCCO SOFFIT TO BE MODIFIED A (E) PLYWOOD & STUCCO V-15" EXTERIOR WALL TO REMAIN 2" OFFSET SOFFIT & OVERHANG 3,Y2" WALL �(E)SUSPENDED CEILING PANELS TO BE MODIFIED FOR PROPER CLEARANCE AS REQUIRED BY W.R.F,D. To, (E) DOOR OPENING 11'-10" ABOVE SLAB TIMBER GUSSET w. Its (3/4" THICK PLYWOOD AT BOTH SIDES OF STRUTS) AT 24" O.C. (N) TIMBER WALL (2x4 STUDS AT 16' O,C.) (N) TIMBER CEILING FRAMING (2x6 STUDS AT 24' O,C.) (N) PLYWOOD & STUCCO SOFFIT [MATCH EXISTING] TO. (N) DOOR OPENING 12�-10" ABOVE SLAB TO. (E) DOOR OPENING . .... .. .... ........... . ' - ...... 11'-1G" ABOVE SLAB l' -O" VERIFY WITH WR,F,D. 7973 REVIEWED MAR 1 (DATE: 11 94R 2015 (PAPER SIZE llxl7)1 GRID-LINE REPRESENTS INTERIOR GRID-LINE REPRESENTS INTERIOR FACE OF (E) CONCRETE- a )ID (E) ROOF FRAMING HEADER TO FACE OF (E) CONCRETE— QGIRI (E) ROOF FRAMING HEADER TO MASONRY UNIT WALL (BEYOND) REMAIN ( 8" TALL STEEL MASONRY UNIT WALL (BEYOND) REMAIN (± 8" TALL STEEL CHANNEL WITH 2x8 TIMBER CHANNEL WITH 2x8 TIMBER (E) 2x4 TIMBER TOP CHORD LEDGER 2x4 TIMBER LEDGER) () 2x4 TIMBER TOP CHORD LEDGER 2x4 TIMBER LEDGER) EXTENSION OF ROOF TRUSS EXTENSION OF ROOF TRUSS AT 24" O.C. TO REMAIN (E) ROOF SHEATHING AT 24" Q.C, TO REMAIN (E) ROOF SHEATHING TO REMAIN TO REMAIN (E) ROOF FRAMING (18" TALL (E) ROOF FRAMING (1" TALL OPEN WEB TIMBER TRUSSES OPEN WEB TIMBER TRUSSES AT 2" O.C.) TO REMAIN AT 24" O.C.) TO REMAIN SLOPE SLOPE (E) PLYWOOD & STUCCO EXTERIOR WALL TO REMAIN 5)/2" OVERHANG _ 2" OFFSET I 3;" WALL - j I F (E) TIMBER WALL (2x4 { STUDS AT 24. O.C.)- TO BE MODIFIED " —(E) SUSPENDED CEILING PANELS TO BE MODIFIED FOR PROPER CLEARANCE AS REQUIRED BY W.R.F.D. To(E DOOR OPENING (E) DOOR HEADER (2-2x12 TIMBER) TO BE MODIFIED (E) PLYWOOD & STUCCO EXTERIOR WALL TO REMAIN 5y2" OVERHANG 3," WALL (N) TIMBER WALL (2x4 STUDS AT 18" O.C.) (N) PLYWOOD STUCCO SOFFIT -- [MATCH EXISTING] 2" OFFSET M. ---(N) TIMBER HEADER (DOUBLE 117/8" LVL) G ) DOOR € PENIN 12`-10 0 A OVE SLAB O. (E) DOOR OPENING I I' --1G" ABOVE SLAB 1'-0" VERIFY WITH W.R.F.D, APPROVED Subjed to Field Ins Wheat Ridge Building1. Q S°grod... -Plin Checkerg 37 73 c, IEEE NEWSECTION DERIL THRU HEADER MAk 1 12015 Ai" R = 1,_G" (DATE. 11 MAR 2015 (PAPER SIZE 11x 1 i) Sp� �w / / q W A' RANT - 110 "0 Win# 1d5 AVE4 HRA.TRIPGE,J 0,00033- w Fat the Hatsilt 6*. ba'n . y,'�v , err , a rit s�t 6 the Company lea jo pe o 16b: FVek6 nR 6 nq Mks �6�6!iIONS�ANDJLI _Tr 'M oniy thoFOstone N�o&one,bta6d r66flnq ihuu1ab6�s,.F*estnhi �raod' I n mean ran i q roitbi;, and -otlierfirdStino- brtnd.r 669 op n`,t , e'event aMV should c tho�Systain, the 'Owhar must give native ih, an"o oflre4 Oro- the str ar n " 't �'. v'l ehce:66thlipoks'shifflia �tha by Ovine�. of, a. Ackooiv1od46m6i,b'V ` s6, n ot 1 fyJ n gL Firestone, tb6.0\4vn6r a t onzes Ftrest a of its deif4had tax Investfgate the: cAu h se of ,the e leak, if iip6n _investigatld Fireiforie the leak i s not excluded'under, thp. Terns binliatfohs:sif Ibrai in this" e w p2 be 11 Ite 'to on re ir'6fth6.)eak', Sho"U'ld the' 1n'vdsflqetidn4eviat 6it-& �16a'k'ls 6miti3fitins, thO,Ou0)6r'5 ne D 'be .oxeldde :unties the Terdns;. eesp I oftsibfis f PaYmliht,�6t. F'Oune by to'Aay this Ljihjtdd'Wa'rri6iY huff and uofd.' Fledi6no Wil Madijt the'Qlydqr�i. qipenjijhot'w'hCperrhij t his Ljiihted W4rranty'tq to effect Tsar ttsp" unexp4r'ed'.P{?rrtieari oP. it; term. ,Frtiture by ttia C}WneFta, property make theserepalrs in':a reasan�6le madnar,usrrtg a Firestpna dIt<�nsed d vithhi 6Q shad , '.4ppHcAtJr,dp' fender this •G9mcted'Viarfatsty r u,N and valid.`: There fe:6p:61(iir llinit placed 66-warranled eak repairs to the 'oxtont,:sjqft, : repairs pluud' dlspute,ceqtr&�er`sY 6�ilalm.beti�40_rrthp be, sett ed py, mediati on, In the 0 - Any I . event,th I at(Mbiobtr and Fiqis�n)hdclo�nbf tesdivs io,m6diatibri; thidvrp& d-Fi 'i6r est6fie a4rdli:that'oNfher :Oefty 11 , , , - - , , , of.�H'a'vofltc`n.'C'nv m the s6ti,6`f'Ihalab�.cy toe'Qili S' r commtnce.orp In"thi ie4 State bisi iti , acb,porty Irrevocably consents to th Gc'ur'f So'uthe'rn' itt'rf4 6fl n,d!Ana,' ,IndianapVlii,Diyi4ioii,: • IF bbiftiotl6h, afnder hats li iaited ehii bmil:Fjre§fbhd,and'tbV havirbeen ih 4 M d ecs i 'warraptyeb ca - wh % " '4 d 'uthee casts t6h ard-inclUded in; �&r,jriocie "at, ' 'In - Syst I em, Jip-thq event ' , rjll�t to susp6nd't is t i r Warranty urst €t:quoh.rep r5 hour be en C< Ia €eted nci.tfte' i censed,agapltc star a?i€!or Fir "estone baibuen"p'aJdjn"fh1l h or any6thr ile iftly, i " 1� " )i6W6r'i6 lh#futtire 1(8''leok' (a) to nmk Oebrls',' 1S§h'trl6`q' etot a ot I 4RH rn?tern" v' J, pr3doXcesse 6y' any `pdntoh; ur tertortSm or Uarsdalispn, whld# datha§e the 5ysterti. We p e, but, not ll4jltVd' to, '1bosir if�m`s'llstjd on thv&16p6 Cara and. fvlaintitidnci " " "d C throu.9 h;- or qroun ft the Wa,.00'pmgs, �roo op hardWai o, on 4u Pmen re AC found n'g i v44,confroct6r;',andj4rn'6C xap,�. isteni n6t'cqmpiob-d,bY en In pq Anti fbok g nd yv Mptid astothe §ttct iffy rzf ifs :. i,6iht 'f* uss accdsdorids caused, by nge4a '" Dtirhig , tb�: terin of t W 4rfanty; Firestone's The Eeritr his Limited d" gnatea'ii0r6dnfdiive �lir' S emolcy 4e fl' St' 11" Jal - .'rokirkVirid'd4r1hq� inspedled and�driipiir bf'Ord'Sysbori. thit'are'due -to'clatiji- jsidcfateil4lth sa .()stirrer "sirbll 154, neipd4sibfe 'for' the - &'ha4i ee6sacf 6y,-hani641 P'60 ston Wit` . ..... a Astor fo.� 36Wjjj, fal6re, to iA6rco`phy''6f the`td'r`m$',dr cqn,01hoh's stated dhnstrqid,Ss a'Wai af such p�M'vlsioq br'bf any OiNer hirmvan� c9ndttl6h5 6tthlK Otened warranty % Limited Wbrrartir to atchrdaoc. �sdii h6i [Aw" s :iof th 'inniahn evlbbtiutiegard to that Warranty Wbeinval 61"tblibm it6d, Is held by a'cquft oftorn ebatit 4ri6di " " forceable, t!hir'ro , m6i fl ESTONE DOES. NOT WAPRAN 5IN Pk filISINSTALLATION SSUST, E klhitI5 i5Y,dT CAljgE y THIS: UPOIfTECt WAk�ANTY, SUPER$tp Ai Is iN LIE '0 11 V FAtL Eft-WARRA LIMUEOMARRAN,TY StiALL-BE` O VNtR,S EXCLUSIVE , REMEDY ' -AGAIN!�T'F'IR 6f4�,,At4D FiRtSTQNE 'hbT,SE'LfA LE- FOP,'Ai4Y,tONSt(�UtNTIXC,'S'Ptt!AL; ifiCjdENTk U' WAY EXCEPF I AME 'Ek 'ER6'Ok,`M - A NY S N 15 ALT ODIOI&IN' . To" e1w t-iRESYONE WJTH-AN�, bA \�RIMN NY AUTH0,11Y. TS"C P�J RiE�,tOMA-tUjLDINd, 0 By Phil 7, Au'thor,40'.- Si t ran I ts of W at CDAv4;1�UP7ITY EV LOPM t*T •w' City, State, Zip: Contractor'. W ON C ontractors City License #: 001-1 H 1 _... 'hone. Plumbing: Mechanical; City License # City License # City License # acessarVI a , PUBLIC WORKS COMMEW& Revi DATE. t OCCUPANCY* 1 Colony "' Wo Ticket Wheat Ridge Fire District Ad d Ilp III GI III 10 901 W 38th Ave Wheat Ridge O 800 " y pul P r1 1Oi ��'•� If� .. I.. pii �i: I 11 � iii mi Elul �. , it II����� „ i u � �� II j �u� lio lu m i p UI r� �I� '� i I u 1 1 iA p II IN lulu i M III !' III II I i Ii I "I =7 pplicatio n .• *m M.�'�II lls�pl 5 pe 4X8 board Application IUD � pu • A ttach Mem III ■ "A plication P i1 *• �� ii C� 1� III P9 X11' IM 14 II I I M !� II MI IU w t Zach • � III I ! Br i an E Job Specific Installation Instructions b remove vertical ''membrane flashings only. Replace wet or dama;;; Membrane/" insulation; document and notify owner of any areas to be replaced. Existing BUR; gravel to be rem oved by • ! i; After rock i of •i• fi be r mec a tt ac hed to wood deck a • Fasteners pe t. i board r olls ,attach S'X 100' o f TPO •i 'Run new membrane up parapet walls to existing coping cap (to remain). Metal Division to install new slip flashing and scuppers. See job specific details for further information. INSPECTION RECORD occupanclUype INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof/ French Drain Sewer Service Lines Water Service Lines INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. F6-n N. C.n'... t U. I IL AUUV t 6A5 OLLN aIGNED CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) ROUGHS Sheathing Lath / Wall tie Mid -Roof Electrical Service Rough Electric Rough Plumbing Gas Piping Rough Mechanical Framing Insulation Drywall Screw FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping * * NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTEAUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER ► ♦ CITY OF WHEAT RIDGE � " Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: IYFZ Job Address: 10701 W X Aiii Permit Number:' ta2SZ 3 ❑ No one available for inspection: Time f t AM /P Re- Inspection required: Yes No *When corrections have been made, ca for r ipection at 303 -234 -5933 Date: ///;Z Inspector: i DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE - Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: 111F, Job Address: 10 7'o/ of 3 Permit Num ber: 1a2 S'�Y ff� k�r'tfr/ ,�y�'- .d..4�3Lf �i� a�z�5 %m ❑ No one available for inspection: Time A /PM r Re- Inspection required: � No When corrections have been made, cal for re inspection at 303 234 - 5933 Date: /z, f i Inspector T� DO NOT REMOVE THIS NOTICE City of Wheat Ridge Commercial Mechanica PERMIT - 102523 PERMIT NO: 102523 ISSUED: 11/04/2010 JOB ADDRESS: 10901 W 38TH AVE EXPIRES: 11/04/2011 DESCRIPTION: Replace 80,000 btru furnace * ** CONTACTS * ** owner 303/424 -7323 sub 303/424 -1622 Wheat Ridge Fire Dep Jack E. Major Jr. 01 -7013 Major Heating ** PARCEL INFO ** ZONE CODE: UA SUBDIVISION: 0191 USE: UA BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 2,700.00 FEES Permit Fee 93.35 Total Valuation .00 h) * * * * L.`.;, J TOTAL 93.35 �'' . -:: °r s:..,,.. �' Conditions: Must comply w/ 2006 IBC & 2005 NEC. Smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. Carbon Monoxide detectors are required to be installed within fifteen(15) feet outside the entrance to each sleeping room. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this appl' 'on and that I ssume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other a icabl A Wheat Ridg/Ardina ce , for work under this permit. Plans subject to field inspection. date 1. This was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 150 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty -four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject to field inspections. Signature Building Official N(9EQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY: Q WREgT 0 9 �; o v m C OGORP 00 Property Owner: W 1.,QnA i y— '-.i KO- Property Address: (03 .(,3 325 �� Ave Contractor License No: i Company: Phone3_y.51 7 Phone: 3- OWNERlCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I Building Dept Valuation Figure: $ I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that a1I measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work underthis permit. Plans subject to field inspection. (OWNER)(CONTRACTOR): SIG --) DATE (OWNER)(CONTRACTOR):PRINTED , keTLYL>4 ® sC dr( DATE - tO Use of Space (description): f j /W— "00 Value:$ 27oo,06 Permit Fee:$ Plan Review Fee:$ Use Tax: ki .414 Z Total:$ Description of work: q'''' a C6 ReJ•Oucc a Id Fu - s�all �r000 r3 ry q Sq. Ft. added rLI I- _ i dw,9 BUILDING DEPARTMENT USE ONLY Approval: Zoning: DING COMMENTS: Approval: .IC WORKS COMMENTS: Approval: DEPARTMENT COMMENTS: Approval: City of Wheat Ridge Building Permit Number: Community Development Department Date: BUILDLVGPERWTAPPLICATTON Walls: Roof: Stories: Residential Units: Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This permitwas issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit may be acquired for a fee of one - halfthe amount normally required, provided no changes have been orwill be made in the original plans and specifications and anysuspension or abandonment has notexceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for anew permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, anyviolation of the provisions of the building codes or any other ordinance, law, rule orregulation. All plan review is subject to field inspections. Chief Building Official - "'q. ♦ 1 i CITY OF WHEAT RIDGE r 4000 or Bu ilding Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: 4+(C Job Address: Permit Number: C3`T f 71- e Cat ❑ No one available for in ction: Time � S AM Re- Inspection required: (t es No ' When corrections have been made, call for re- inspection at 303- 34 -5933 Date: ` ' t Inspector: _ V8 z' z ♦ i CITY OF WHEAT RIDGE r Building Inspection Division f (303) 234-5933 Inspection line (303)235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 1 J ,0'V'e, Permit Number: r 20 q7;) ❑ No one available for inspection: Time AM M Re-Inspection required: Yes ;No When corrections have been made, calf for re-inspection at 303.-234-5933 Date: d) ( Inspector: lPr DO NOT REMOVE THIS NOTICE INSPECTION RECORD OccupancvlTVpe 'INSPECTION LINE: (303) 234- 5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. d p INSPECTOR MUST SIGN ALL SPACES. PERTAINING TO THIS JOB FOUNDATION INSPECTIONS INSPECTOR DATE :INITIALS C OMMENTSI Footings /Caissons :.. Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Heating (underground) Weatherproof I French Drain 'DO Sewer Service Lines .ROUGHS - Sheathing: Water Service Lines' Mid Roof - i �,.:.` Electrical Service Rough Elec tric" ± '..POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (underground) 'DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED .ROUGHS - Sheathing: Lath I Wall tie Mid Roof - i �,.:.` Electrical Service Rough Elec tric" Plumbing GasPiping " ROughMechanical ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING f Framing Insulation t Drywall Screw �s r FINALS Electrical Plum Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. * *NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A'..' CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION = OF.A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED t PROTECT THIS CARD FROM THE WEATHER ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: In/ Job Address: 107e i Permit Number: oy9 ?9P 72 ❑ No one available for inspection: Time L S AM/ ND Re-Inspection required: Yes C When corrections have been made, call for re-inspection at 303-2345933 Date:_!t/Fo/6.9 Inspector: % DO NOT REMOVE THIS NOTICE " 1 City of Wheat Ridge _ir ►J Residential Roofing PERMIT - 093872 PERMIT NO: 093872 't ISSUED:: 11/05/2009 JOB ADDRESS:' 10901 W38TH AVE -'EXPIRES: 05/04/2010 DESCRIPTION:. Reroof 17 sqs of modified and 37 sqs of asphault shingles CONTACTS owner 303/403-5900 Wheat Ridge Fire District sub 303/426-4200 Chuck Borden 02-2016 Interstate :Restoration, LLC **PARCEL INFO ZONE 'CODE: UA `USE: UA SUBDIVISION:. 0191, :BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 26,542.00.. FEES Permit Fee 534.96 Total Valuation .00 Use Tax 477.76 /A ) TOTAL 1,012.72 Conditions: ` 6 nail installation& mid-roof inspection required Board sheathing spaced more thanes 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield' required from eave edge to 2'`inside exterior` walls.` ***Contractor/Property owner shall provide ladder(s) secured in place for inpsections. Subject to field inspection:'. I hereby certify that the setback distances proposed by this permit application. are accurate, and do not violate. applicable ordinances, rules or regulations of the City of <Wheat Ridge or covenants, easements or restrictions' of record; that all measurements shown, and allegations made are accurate; that. I have read and agree to abide by all conditions printed on this applicat on and th I ss e full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applica pe~,heat a nances, for work under this per /it. lans subject to field inspection. Sig a ure of contractor/owner .:date 1. This permit was issued in accordance with the'. provisions set forth r. in vour application and is subiect to the laws of the LDING OFFICE: (303)235-2855 FOR INSPECTION THE FOLLOWING BUSINESS DAY. ` W HEgT City of Wheat Ridge Building Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 CO<ORPOO Inspection Line: 303-234-5933 Building Permit Application Property Address: j09~/ ltd 58". AT'wr Date: Plan Permit o Property Owner (please print): 1J)Aee-.-1,?Wd '14tJ~~l //oyt PhoV/s~~' / /fr° ne: L363) Yt, `5760 Mailing Address: (if different than property address) Address: State, Zip: Contractor: /NT ZSrffY[ iT7J/ T70n~ f cfZ2p r~ 6i uniT l0,( fJe~Vdc Cp ~oZ3% Contractor License Phone: Sub Contractors: Electrical City License Company: Exp. Date: Plumbing City License Company Exp. Date: Mechanical City License Company: Exp. Date: Use of space (description): zoFigTi Construction Value: ,2~ V , r ~2 - (1[1, Description of work: (as calculated per the Building Valuation Data sheet) / / 7 JQJfl~~"'~S No o FIND ~J 7 $4uvt:3C-3 Plan Review (due at time ofsubmittall: $ r15, 1Nz1f 6 f4 rrn 5les Sq. Ft./L.Ft added: Squares BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby cert ify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE: (OWNER) (C TRACTO or PERSONAL REPRES NTATIV f NER) (CONTRATOR) PRINT NAME: N0rn 4F I/ O Date: /I S if Z,?, Bldg Valuation: $ , City of Wheat Ridge Residential Electric PERMIT - 080889 10PERMIT NO: 080889 ISSIIED: 08/08/2008 JOB FII,)DRESS: 10901 W38TH AVE EXPIRES: 02/04/2009 DESCRIPTION: Wire phase converter and compressor CONTACTS owner 303/403-5950 Wheat Ridge Fire Dept gc 720/379-3237 Tim Verrier 08-0183 Cornerstone Electrical Cont. PARCEL INFO . ZONE CODE: UA USE: UA SUBDIVISION: 0191 BLOCK/LOT#: 0/ FEE SUMMARY _ ESTIMATED PROJECT VALUATION: 1,800.00FEES Permit Fee 82.16 Total Valuation .00 Use Tax 32.40 TOTAL 114.56 Conditions: Must comply w/ 2003 IBC & 2005 NEC I hereby certify that the setback distances proposed by this permit application are accurate,and do not violate applicable ordinanres, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurementsshown, and allegations made are accurate; that I have read and agree to abide by a11 conditions printed on this application and that I assume full responsibility for compliance with the Wheat aidgeHUilding Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subjecEto fieldinspection. Signature of contractor/owner date 1. This permit was issuedin accordance with the provisions set forth in your application and issubject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado.or any.ather applicable ordinances of the City. . 2. Thispermit shall expire 180 daysfrom the issue date. Requests for an extension must be received prior to expiraCion date.. An extension may be granted at the discretion of the Building Official. 3. If this.peYmit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plana and specifications and any suspension or abandonment has not exceeded one. (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, fu11 fees shall . be paid for a new permit. 4. No work of any manner shall be done that will change the natural £low of water causing a drainage problem. 5. Contractor sha11 notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval oninspection card before proceeding with successive phases of the job. . 6. The issuance of a pexmit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violatio ofthe provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is s ~g~tield inspections.GiV Signature of Chief Hui ing fficial date . INSPECTION REQ ST LINE: (303)234-5993 BUILPING OFFICE: (303)235-2855 REQUESTS MUST BE MADE.BY.3YM ANY.BUSINESS.'DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. : ' OccuqancVlTVpe 'r-INSPECTioN LwE: (303) 234-5933 1nspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the foilowing business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS : Dpie INSaecio2 INITIALS COMMENTS Footings/Caissons - Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lires . Water Service Lines aicrveo FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage - Parking & Landscaping START ALL ROUTING ONE WEEK PRIOR TO FINAL INSPECTIONS. "NOTE: ALL ITEMS MUST 8E COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING ANO PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY lS ISSUED. FINAL INSPECTION BY 7HE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION . OF A CERTIFICATE OF OCCUPANCY NOR PERMI SSION FOR OCCUPANCY. UGCUPANCY NOT PERMfTTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED F°ROTECT 1'HIS CARD FRO(V( THE WEATHER / 4' CITY OF WHEAT RIDGE ~ Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax t r INSPECTION NOTICE Inspection Type: Job Address/Permit Number: /~/J~ZD/ ~ No one available for in~ tion: Time . M M - e-Inspection required: ~ es No `When corrections have be~ ade, call for re-ins~ction at 303-234-5933 Date:o ~ Inspector: < . A 41 CITY OF WHEtAT RIDGE Building Inspection Division ~ (303) 234-5933 Inspection line (303) 235-2855 O/fice ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: ~ JobAddress/PermitNumber:~j~/~~~ ❑ No one available for inspection.Tiine _ AM/PM Re-Inspection required: Yes / No 'When corrections have been made-call f r re-ins ection Date: 414;1nr-) Inspector: A NOTICE DO NOT at 303-234-5933 City of Wheat Ridge Residential Eleetric PERMIT - 080889 -PERMIT NO: 080889 ISSUED: 08/08/2008 -JOB ADDRESS: 10901 W 38TH AVE EXPIRES: 02/04/2009 , DESCRIPTION: Wire phase converter and compressor CONTACTS ~owner 303/403-5950 Wheat Ridge Fire Dept gc 720/379-3237 Tim Verner 08-0183 Cornerstone Electrical Cont. PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION: 0191 BLOCK/LOT#: 0/ Conditions: Must comply w/ 2003 IBC & 2005 NEC. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that ali measurement shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this applicati and that~e full responsibility £or compliance with the Wheat Aidge Suilding Code (I.H.C) and all other appl' 1 Wheat e Ordinances, for work under this permit. Plans subject to field inspection. Signature of contractor/owner date 1. This permit was issued in accordance with the provisions set forth in your application and is subjec[ to the laws of the . State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. . . 2. This permit shall expire 180 days from the issue date.Aeguests for an exeension must be received prior to expiration date. M extension may be graatzd at the discretion of the Huilding Official. ~ 3. If this permit ezpires, a new permit may be acquired for a fee ofone-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the naCUral flow of water causing a drainage problem. 5. Contractor shall notify the euilding Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card be£ore proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject ield inspections. ~ . Signature of Chief Bui i g ficial date '-INSPECTION REQ ST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 . REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Building Division ~ m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235 2857 ~ Inspection Line: 303-234-5933 ~CORP~O Building Permit Application Property Address: 0 1 3q 'tk AJC Property Owner (please print): WkeFf A4 e ~.Ye Mailing Address: (if different than property address) Address: Date: Plan Permit Phone: 30"3 ~"i03 515-0 Citv Sfate_ Zio' COI1tr8Ct01': W,iQY'C!B-/'S'l~Ohe ts-I2G~'N)Ga~ Co^e Contractor License O g "D Phone: -7 *LO 3qi 7137 Sub Contractors: Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction Value: 8 (as calculated per the Building Valuatfon Data sh D@SCrIpflOfl Of W01'k' eet) ' ~✓,'n.. ~ASe Go n da+~~ ^ ~ ~M Plan Review (due at time of submittal): $ Sq.FtJLFtadded: Squares BTU's Gallons Amps 1"' OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCEONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR) PRINT NAME: SIGNATURE: Date: ZONING COMMENTS: Zoning: Reviewer: . Reviewec DEPARTMENT USE ONLY PUBLIC WORKS COMMENTS: BUILOING DEPARTMENT COMMENTS: OCCUPANCY: Reviewec FIRE DEPARTMENT:: ❑ approved w/ comments ❑ disappfoved ❑ no revieW requifed Bldg Valuation: $ CERTIFICATf OF 4CCflPANCY CITY:O.F WHEAT RIDGE Perrnit Number 060743 750,0 W. 29th: Avenue Date Februarv 27, 2007 W 5eat~Ridge, Col'orado 810033"StipuleEions: This certificatsverifies that the building constructed and/or the use proposed of the building and/or premises, under the above permif number and on property describetl lielow, doescomply wYh the Wheat RidgeBu1ding Code, Zoning and other relatecl' landuse'and ileveloprrient lavv%s of~the,elty of 1Nheat Risfge, and rpay be occupied for the use speGified. OWNER WHEAT RIDGE F"IftE PROTECTICQN ADDRESS 90901 W. 38TH AVENUE CONTRACTOR ADDRESS> TC2 INC; P.O. B"OX 1018 EUERGREE"N-, CO 80437 PROPERTY ADDRESS 10901: W. 3$TN AVENUE LEGAL DESCRIPTION: FOR THE FOLLOWING PI:JRROSE ' COR/}MEf2CIAt ADDiTION lJSE Code eaitions: Nd change shafl be made in the Use of this building wathout ' sarinkiered: 2003icc i2oozNec' prior noti* and anew CertifieaEe of Occupancy oves o~ iss7uec i2qoz NEC ,frd~i 31~e qftjr .of *-laeaf Ridg-e ; ~,-N ° . . /`~1'. V \^..-.,.V i . ✓`~'4" i1'~.^.n ni'.lN'/'v~.i`.v v ~v v'i v ~ . . ~ ~ . . . % Date: ~.~L7~ C71 : ; A Certificate of Occupancy 7 Complefion ~ has been requested for; ? ; ~ ~ Qq L I Vj ~ Pi3RPOSE OF STRUCTURE: Y1M 1'~~~ 1^ < Building QepartmentApproval: S ~ ~ Remarks: ~ Zoning App..roval• ` Remarks: o . ti. ~ ~ Public Works Approyal: y < Remarks: ; $ Fire Matshall Approval: t (If Appticable) , 1 • ~ . . . _ _ . _ . Remarlcs:.. < S : ; Sanita4ion District Approval: ~ (af Applicabie) s ` R$(T72rkS: . ~ ~ Water Distr~ct Approval: ; (If Applicable) ~ Remarks- ~ S > < i ~ S ; } 2 S z S 2 S ~ r ' r r M a ~ M ° d LU ~ 'o r A > ~ ~ C 2c Q O M ~ ~ N 0 V M N Q = ~ C) ~ v C N LU ti m ~ ~ Q L ~ _ ~ 2c a> w ~ d ~ C 0 'a w 0 a N V l0 ~ N tA N m C ~ d ~ d ~ c .y ~ m G. N G H ~ 0 d a ~ c L w ~ ~ 3 ~ v O c ~ 7 O _ N U C ~ a :3 8 ~ a ~ y t.: IQ da 0 Q ~ (D ~ R p .n o ~ n m~ m 0 ~ z x U ~ o c9 Z a ~ ~ ~ w a ! Q a Q a a J ~ Q Q > , (5)7 ~ w ~ 'a o w ~ ~ ~ . o j Cc (A L Z Z O ~ l a ~ U ~ • c ~ tY~ ~ E n V- ' v ~ ~ ~ K ~ LL ~ ~ a Q ~ -0 c ~ . ~ v C LM (D D 2 U ~ i ~ ~ ~ ~ ~ im ? ' e G. a A ia .C ~ m w rn a L m Hy = ~ ~l n ~ ~ ~ ~ c a ~ ~ V Z y W . ~ ~ ~ 2 O ' ~ W A . ~ Z J ~ \ \ ~ c a Z # ~ LL 0) • ~ E ~ c c ~o V LL i J-2 O ' ~ Y a Q Y . LJ. 0 W ~ a V ~ ~ W W W Q (1) _ ~ ~ ~ W Z U) 1z- - LiJ Z u. ~ CL a W V ~ ap= O W Z o V ~ Z (L a V V r~1 ~ Lm 0 V ~ CL . Av/ H ■ a ~ ~ ~ LOM O vj4 ~ ~ Q ~ 4ma am ; ; V 0 ~ to ui L ~ ~ ~ ~ Q I \u 1~ ~ ~ : r ~ t a v ~ > . ~ ~ D 0 \ I V m V II Z Q 0 i I 45.00' 20.0' 69.33' 145.67' i N 90'00'00" ' - - - - - - - - 280.00~ N O ~ W o ~ ° Z / m ~ D Z ~ N 'cmD ~ ~ m ~o_ a; V/ ..~pI 0 O ~ A 00 ~ D - - - Z "C"l C A . ~ ; • ; ~ ; • ' . ~ ~ Clt 1 ~ 1 , ;:~':.~('a'. '•i'. r fA ti'' o ~ •c~ . " g .n°. o~ Z c~i o '~°r: : a' a v'oA z r^ ' .3.. o ' ~ Z N .:l, . . ~ ~ ,..;:'.'~;;.::NZ; f:. o ; . tn • . p e f . m : : : : ~ ~ ~c~ '~i7~.rt~~~'~•J''•(y'.?C~ ~cZ'f i~•~ .:t.. . ~ / / . . : • y'= . . r~5 ' . . .Y.N • . ' . O .~.0~~• , . . . b. ~i.~_... . . . . . . P _~'e~E>. a ~ ~ ~ ~ ~ C r p C Z N Z ~ N 20 r., N ~ ~ .m. D s l7 20.0' ~ D ~ D N O Q A ~ C) ~ m v ° O z -a = r~. ~ O N ~ r .1' t . . .1:. : y`. •T . • .a . ' • G'> , V ^ ~ • It Z ' :rt. . Y. ' ~.c .•O~.'. V ~ ~ ~ Z C ~ A m x m m 2 y ~ m n Avz N r ~ N 6 .Z) N ~ N ZGZ7 N N 90'00'00" m II II o U mZ U ~ N , D 5~ m ~ ~ .oo' o ~ ~ ~Z ~ 0 N a Mv z c~ m x m ~ ~ ~ ~ v N 5 y + Z ~ CS ~ N X O - S n m ~ ~ C r ~ ~ . .l . D \ m ~ ~ W OD 3 V t / rn 69.33' N 90*00'0On 280.00' m _ ➢ ^ D ¢ D ~ O ~ N ~ r Yt • • : t . : Yj •T: 'o ~ . : . . ~ . : ~ : , /'r*! • : ~ ~ ' 'i: • O . ~ : . u '.+r•. : ' ' ~ `f 'l~.•~}^..1. ~ . . 1 . , ..~'e•~_• •n%%. . _ . y. . '.O m m z -:a ~nvx N r ~ ~ N ~ ~ ~ pX = N ~V O ~ n ~ ~ o~ v Z c~ ~ t7 N a ~ m 'O 25-m z c') m x m ~ - Z A G~ ~ ~ ~ (lj~•f• \ / <n m o ~ Z x ~ S> m \ m U) ~ W ~ V D m COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice Job Address: 9~/ ~ ~h ~4✓~ ~Cl!//L,O/ivG F/NAG When corrections have been made, call for re-inspection at 303-234-5933. -Q5-07 DO NOT REMOVE TH/S NOTICE zVel T Z.-9 si dit/ ,BUi~.o.,~ os .c~..✓ COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice Job Address: When corrections have been made, call for re-inspection at 303-234-5933. /f _ Inspector COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice Job Address: .:O ~rca~ ~ll6H ~Eiu.✓/ F,~s~Gr.rcy fil,sfT rRe.y ~,Py,o .53<K~sf_ ~ ~ L orLX .-~!/SS~.✓6 ~ ~G'!~5'~.eGr ~ / 'o.✓~A~T.t ZOC?~f~ie/ When corrections have been made, call for re-inspection at 303-234-5933. DO NOT REMOVE THIS NOTICE City of Wheat Ridge Commercial Fence PERMIT - 061129 PERMIT NO: 061129 ISSUED: 11/21/2006 JOB ADDRESS: 10901 38TH AV EXPIRES: DESCRIPTION: 6' chain link fence along side and rear property lines CONTACTS gc 303/469-1317 Vern Knorr 06-0207 Metro Fence Company owner poug Saba Wheat Ridge Fire District PARCEL INFO . . ZONE.CODE: UA . . . USE: UA SUBDIVISION: UA BLOCK/LOT#: 0/ . FEE SUMMARY ESTIMATED PROJECT VALUATION: .00 . . . . FEES No Fees . . ...00 TOTAL .00 Comments: - - - 6 foot chain link fence along side andrear property lines I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate;-that Ihave read'and agree to abide by all conditions printed on this - applic - an hat I assume fullresponsibility for compliance with the wkreat Ridge Building Code (I.H.C)-and all other app cabl W Ri e r nances, for work under this permit. Plans subject to field inspection. . - . 2 V C, . Signature of contractor/owne . . . . . dat . . . . . 1. This permit was issued in accordance with the provisions aet forth in your application and is subject to the laws o£ the State of Colorado and to the Zoning Regulations-and Suilding Codes of wheat Ridge, Colorado or any other applicable . ordinances of the City.. 2. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date oP (B) -the - building authorized is suspended or abandoned-for a-period of 180 days. . 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans. and specifieaCions and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid Eor a new permit. 4. No work ofany manner shallbe done that will change the natural flow of water causing a drainage problem. 5. Contractor shall noti£y the Building Inspector twenty-four (24) hours in advance £or all inspections and shall receivewritten approval on inspection cazd before proceeding witti successive phases of the job. - 6. The issuance of a permit or the approval ofdrawings and specificaCions shall not be construed to be a pesmit Eor, nor ' an approval of, anp vio` on of t e pr s of the building codes or any other ordinance, law, rule or regulation. All plan review is syi~~'c~to fid i s o,. - 00- Signature of Chief ilding Offical date INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: oF W"E4r ~ BUILDING INSPECTION LINE - 303-234-5933 Date: ~ a CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE PLAN # WHEAT RIDGE, CO 80033 - (303-235-2855) TIQN cOCORPO~ MIl lOR rYAPLICA Proper[yOwner: (21,*~ v~ \ HEA-r'f-, flbc irr.-~ Properiy Address: tCJ d i •3 Q~ r" /-E ✓ c Phone: Confractor License No.: i Company: MGTk2o f_CNCC (2O Phone: '3p3 - ~{6 6D - 13 1 _;2 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDINGAND AGREEMENT guildinq Dept. Valuation Figure: $ I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Value:$ Wheat Ridge orcovenants, easements or restrictions of record; thaf all measurements shown, and allegations made are accurate; that I have read and agree to abide by all Permit Fee:$ conditions printed on this application and that I assume full responsibility for P11ri ReV1eW FBe:$ compliance with the Wheat Ridge Building Code (I.B.C) and all ofherapplicable Wheat Ridge Ordinances, for work un ii rmit. P ans subject to fieid inspectioa US0 T3X: DATE<< 2( ~ k TOYSl:$ (OWNER)(CONTRACTOR):SIGNE m~ Use of Space (description): Descriptionofwork:-r_~f}'(- VW-- Sq. Ft. added S, d-t ~~-Qr pv-rp' BUILDING DEPARTMENT USE ONLY SIC: I COMMENTS: ~ 1 Approval: ~ Zoning: G COMMENTS: 1 . Approval: fORKS COMMENTS: Approval: DEPARTMENT COMMENTS: Approval: Walls: Roof: Stories: Residential Units: (cA_L~ Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) ihe work authorized is not commenced within sixry (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been orwill be made in the original plans and specif cations and anysuspension or abandonment has not exceeded one . (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. . (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regula6on. All plan review is subject to field inspections. . Chief Building Official COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice Job Address: 7r)l r /m/ , 4U~ ~ - 1ii-'Sc.g4 .'qL 7-;~' gv 'V' When corrections have been made, call for re-inspection at 303-23d-5933_ COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice Job Address: ~-0A~~~l leab~1;1-71 When corrections have been made, call for re-inspection at 303-234-5933. COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice Job Address: ELECT,¢~C.9G .2ol.t>~'6! • 41~ Ty,o~ ~~.2~.✓G /1~.~✓ ~~ss T~/~vv.,i ~.P~~ When corrections have been made, call for re-inspection at 303-234-5933. DO NOT REMOVE THIS NOTICE City of Wheat Ridge Commercial Addition PERMIT - 060743 PERMIT NO: 060743 ISSUED: 08/15/2006 JOB ADDRESS: 10901-38TH AV . EXPIRES: 02/15/2008 DESCRIPTION: Firehouse addition. 2500 sq ft CONTACTS owner 303/403- 5902 gc 303/670- 0084 sub 303/699- 5832 sub 303/424- 7200 sub 303/794- 2516 Doug Saba Stefanie McKelligott Matthew Allsman Susan Tinkey - Wheat Ridge Fire Protection Di 02-1412 TC2 Inc. 02-1405 Grizzly Plumbing Inc 01-8167 G& H Electric Co. 02-1780 Westwind Mechanical PARCEL INFO ZONE CODE: R-1C USE: UA SUBDIVISION: UA BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: .00 FEES No Fees .00 TOTAL .00 Comments: - ALL CONTRACTORS MUST HAVE CURRENT LICENSES IN beat Ridgg PRESCRIPTIVE ENERGY CODE BOILERS 1 FURNACES A MINIMUM OF 90% AFUE SUBJECT 'ro FIELD zNSPECTIONS GAS WATER HEATERS A MINIMUM OF.60 ENERGY FdCTOR ELECTRIC WATER HEATERS A MINIMUM OF .93 ENERGY PACT . SEE- PERMIT NOTES ON PAGES TWO AND THREE SE79P.CKTHERMOSTAT REQUIRfD (EXCEPT HYDRONIC HEAY) R-21 WALLS • Ra8 CEILtNGS • R•79 CRAWLSPACES ELECTRICAL NNST MEET NEC 2002 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordivancea, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurementa shown, and allegations made are accurate; that I have read and a9ree to abide by all conditions printed on this application and that I assume.full responsibility for compliance with the Wheat Ridge euilding Code (I.H.C) and all other applicable ~¢¢yyt Rid Ordinances, for work undeis`ermita.~ans subject to field inspection. ~ S' atur contractor/owner date 1. This pemit was issued in accordance with the provisions set forth in your application and is subject to the laws of the Stateof Colorado and to the Zoning Regulations and Building Codes of Wheat Aidge, Colorado or any other applicable ordinances o£ the City. 2. This pemit shall espire if (A) the work authorized is not commenced within sixty (60) days £rom issue Aate or (B) the building authorized is suspended or abandoned for a period of 180 days. 3. If this pemit expires, a new pemit may be acquired for a fee of one-half ehe amount nozmally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid Eor a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. - 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inapection card before proceeding with successive phases of the job. 6. The issuance of a pemit or the approval of drawings and specifications shall not be construed to bea permit for, nor an approval of, any violat' f th the building codes or any other ordinance, law, rule or regulation. All plan review is s xb e f' inspections. . Signature of Chief Building Offical date INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE•(303 5-2655 R~7Z~~7t~e~Au,~ti~ S~Yl b~SINESS DAY FOR INSPECTI~OWING BUSINESS DAY. onsife for final roof i»spection which spe~'y ~ipm - I I istesponibl0 F0t bodngpmperty roofi►eg inaterials have been install¢d tam¢et 1im °°d eonsmwft imp°Vcments acc°rding tO the 1101►PH three-second wind gtavt--= aPP*oved Plan and reNired development standards. The City is not responsible for inaccucate information submitted within the plan set and aay constcuction P.rnrq resulflna from inaccurate information. `J ~ f ~ ~ ~ ~ ~ ~ ~ :l! ~ V/ ~ V ' C~~-oo2~J . OF WHEqT ° _ . ~ Po City of Wheat Ridge Building Permit Number. ~ m Community Development Department Date: °o[oanoo . ~OMMER CIA.4 & MF.E.[.<TI-=,C".~.Fr.~IL Y . . . . BCf,I1-+DING,K"~.~~fC~~F;4 A.S"P-IJCA.SION . . Property Owner: z511 ProperryAddress: /oyo/ -Gzp, s8~ lg~. Phone: ,3nJ•- f/o3°S9aG Contractor License No.: Company: 71~e~ Phone:~os-~'9d~-_a~/8Z -0WNER/CONTRACTOR SIGNATURE OF UNDERSTANDMG AND AGREEMENT Buildinq Dept. Valuafion Figure: $ I hereby certify that the setback distances proposed by this permit application are . accurate, and do not violate applicable ordinances, rules or regulations of the Ciry of . `T2,lUe:$ . WheatRidgeorcovenants,easemeMSOrrestrictionsofrecord;thatallmeasurements ~ . shown, and allegations made are accurete; that I have read and agree to abide by ail P8I1Tllt F00:$ ,tjQ conditions printed on this application and that I assume full responsibility for plan Review Pee:$ compliance with the Wheat Ridge Building Code (I.B.C) and all otherapplicable Wheat Ridge Ordinances, forwork underthis p~r~ ~lans su ject to field inspection. US0 T3_X1:Q+ - (OWNER)(CONTRACTOR):SIGNED DATE TOt[LL:.p . (OWNER)(CONTRACTOR):PRINTED DATE Use of Space (descriptii Description of work: . Sq. Ft. added a~5_,S70 USE ONLY SIC: Sq.Ft.: 1 , r . Approval: . . . : t Zonmg. . ~ . 1 / ~ . . _ . . . . . . . BUILDING COMMENTS: ~ . . Approval: . ~1_,W~• J~~~SQ~IcD ~s Y~I O,/` N' V, 0 PUBLIC WORKS COMMENTS . ' . S~ . ApprovaC . .5~75 . . . . . . . . IRE DEPARTMENT COMMENTS: . . . : . . . . . Approval: ' Occupancy: Walis Roof: Stories Residential Units Electrical License No: ` Plumbing License Na Mechanical License Na Company: ' Company: ' Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: °.(1) This permit was issued in accordance with the provisions set fodh in your application and is subject to the laws of the State of ColoradoandtotheZoningRegulationsandBuildingCOdesofWheatRidge,Coloradooranyotherapplicableordinancesof . . . ..the City. . . , . . . . . ~(2) This permit shall expire if (A) the workauthorized is not commenced within sixty (60) days from issue date or (B) the building . . . authorized is suspendedor abandoned for a period of180 days. (3) Ifthis permit expires; anew permitmay be acquired for a fee of one-halfthe amount normally required, providedno changes - . . havebeenorwillbemadeinthebriginaiplansandspecificationsandanysuspensionorabandonmenthasnotexceededone." .(1)year.lfchangeshavebeenorifsuspensionorabandonmentexceedsone(1)year,fulifeesshailbepaidforanewpermit . . . . .(4) No work of any mannershall be done that will change the natural flow of water causing a drainageproblem. .(5) Contractor shall notify the Building Inspector twenty-fouF (24) hours in advance for ail inspections and shall receive written approval on inspection card before proceeding with successive phases ofthe job. . (6) . The issuance ofa permit or the approvai ofdrawings and specifications shali not be construed to be a permit for, nor an approvalof,anyviolationofthepmvisionsofthebuildingcodesoranyother ordinance, law, rule orregulation. All plan review . . is subject to field inspections. . . . Chief Building Official o0 .2-y ~f WHEAT ' . . . ' City of Wheat Ridge Building Permit Number. ~ m Community Development Department Date: ~CORADO CSd,Fr'~~~ER CM L {74. LY.kUL6~.R~~;R:°[~.~IL Y B~~~DING.,R'."ERMITAPAUCAfi A ON Property Owner: ".ori'l Properry Address: /m~o/ ~ 3~~ J~~-•• Phone: ~oJ- yo3•S9oZ Conlractor License No.: ~ a Company: Phone:-i~.3 OWNERICONTRACTOR SIGNA7URE OF UNDERSTANDING AND AGREEMENT I Buildinq Dept. Valuation Figure: $ - I hereby certiTy that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of W heat Ridge or covenants, easements or restridions of record; that all measurements shown, and allegations made are accurate; that I have read and agiee to abide by all conditions printed on this application and that I assume full responsibiliry'for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this p i. lans su ject to field inspection. (OWNER)(CONTRACTOR): SIGNED DATE 1~5~0 (OWNER)(CONTRACTOR):PRINTED - DATE Use of Space (description): G'(.~ ~ Description of work: Sq.Ft.added 9~5-`~ V31U0:$ Pernut Fee:$ ~Q Plan Review Pee:$ U e Tax: Total:$ ONING COMMENTS: ~r" BUII.DING DEPA~2TMENT USE ONLY S IC: Sq. Ft.: ~ p✓' ~l'~ Approval: ~ Zoning: P O D BUILDING COMMENTS: Approval: 0 V~~ ~ 19 2006 Pl1BLIC WORKS COMMENTS: ApprovaC IRE DEPARTMENT COMMENTS: Approval: ' . - lOccupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This permitwas issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of W heat Ridge, Colorado or any other applicable ordinances of the Ciry. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the 6uilding authorized is suspended or abandoned for a period of 180 days. (3) Ifthis permit expires, a new permit maybe acquired for a fee of one-halfthe amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new pertnit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written . approval on inspection card before proceeding with successive phases of thejob. _ (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject to field inspections. Chief Building Officiai CityofllRaratftge DepartrnerR af Pubiic DEPARTMENT OF PUBLIC WORKS 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 (303) 235-2861 FAX (303) 235-2857 LETTER OF NOTIFICATION FOR PUBLIC IMPROVEMENTS RESTORATION DATED !o 1A>6 Deaz Contractor: ADDREss ieQo/ tJ. 3&4 In conjunction with the approval of the building permit application for the above referenced address, this letter is to inform you that all existing public improvements located along the frontage of said address shall be restored, (if damaged from related construction) to an acceptable condition, as deternuned by City of Wheat Ridge Public Works Department, and prior to the issuance of a Certificate of Occupancy. Prior to any construction commencing, the City's representative will conduct an onsite inspection to determine the exis6ng condition(s) of the public improvements at this address. If you have any questions, please contact me at 303-235-2864. Sincerely, David F. Brossman, P.L.S. Developmenf Review Engineer Cc: File Rev 4/03 OF w~~Tpi DEPARTMENT OF PUBLIC WORKS ~ m COMMERCIAL/MULTI-FAMILY BUILDING PERMIT APPLICATION REVIEW co~aRp9o Date: G/~g `D(o Location: lt790 / W. 38"t~ A'UEti/ Ua ATTENTION: BUILDING DEPARTMENT I have reviewed the submitted application documents to construct a/4aa,naq ra iJR FPD SY. }'17DN 2. xo be located at the above referenced address. Please note the summary commenu below. LProperty Boundary Closure: ✓OK _ Not OK; refer to sdpulations. 2. ~ Drainage: a. Final Drainage Report and Plan required _ b. Drainage Plan & Certificadon Letter required c. Lot drainage/gading is to be reviewed by Lhe Building Division ✓ d. Site drainage/grading has been reviewed and are: _ OK _ Not OK; refer to stipulations 3. NPDFS Permit Required: _ Yes No 4. ✓ Public Impravements to be completed: a. street paving/patching: Yes -t.-No b. curb & gutter. Yes No c. sidewalk: Yes No d. standazd street lighu: Yes v-No e. pedestrianlights: Yes ~No f. storm sewer: Yes ~ No g. letter of credit required: _ Yes _L.-No If a letter of credit is required, for what improvements? Amount of the ietter of credir. $ .v.A± 5. _,e:f SIA/PIArequued: Yes ✓No 6. ~C Development Covenant requ'ued: _ Yes ~AIo If Yes, for ~ 7. ✓ Tnffic impact analysis and report required: Yes r-No 8. ~C State Highway Access Permit needed: Yes ::;~-No 9. J~ Sveet Access Permit reyuired: Yes _L,~ No If yes, was it approved by the Director of Public VJorks7 Yes ~ No 10. ✓ Does all existing roadway/alley R.O.W. meet the standprds of the City: yYes _ No If not, what is requested: - /v ri' Has the dedication been received? _ Yes _ No 11. ✓ APPROVED: The Public Works DepaRment has reviewed the submitted material and hereby approves this Permit Application, subject to the above and/or attached stipulations. J...,.Za4-.~ 41i9lrs Signature David F. Brossman, P.L.S. Date 12. NOT APPROVED: The Public Works Department has reviewed the snbmitted maierial and does not approve this Permit Application for the reason(s) stated. Signature David F. Brossman, P.L.S. 13. ~ Stipulationsattached: _ Yes rNo Date 14. NOTE: Any damage to the existing Public Improvements as a result of this constructton is to be repaired to meet Ciry standazds by che Permit Applicant prior to the issuance of the Certificate of Occu ancy (C.O.). -,4-;iraixnge Gc~€uatiee-Letter is.s..q+ ir•ed r+h •ccua t rhr n- ,~~j DEPARTMENT OF PUBLIC WORKS REVIEW FEE STRUCTURE FOR BUILDING PERMIT APPLICATION Date Applicant Phone # Location of Construction: j b 20 / tJ . 384'``fEuE Purpose of Construction: 13w.4a,,.ve,-,9Da i nonl Building Permit Value: Single Family Commercial Multi-Family DEVELOPMENT REVIEW FEES Development Review Processing Fee: $100.00 ${O 6.66 CklmV8p) (For document processing) Single Fanuly Residence Review Fee: $50.00 $ (For review of applicable technical documents) CommerciaUMulri-Family Review Fee: ~ •(For review of exisring technical documents) $100.00 iO D- Od 6A.$1 VB~j •(For review of technical documenu for conshuction in Right-of-Way, Final Drainage Report, and Erosion Control Plan) $500.00 $ CDOT Access Pemut Fee: $150.00 $ (for document applicarion and processing) - Traffic Impact Study Review Fee: $200.00 $ (For document review and processing) No - TOTAL REVIEW FEES (due at time of building permit issuance): $ G9A*6-.G_ PLEASE NOTE THAT IN ADDITION TO TfiE ABOVE FEES, THERE WILL BE ADDITIONAL LICENSING AND PERMITTING FEES REQT.JIRED FOR CONSTRKTION OF IlVIPROVENIENTS WITHIN PUBLIC RIGHT-OF-WAY. Signature of Applicant , f Cv~ Date g-~ d C)(:, KAFORMS & I.E1"I'ERS\DEVELOPMENT FORMSTee Structwe (6-8A4).doc Rev 6/04 PLANNING & DEVELOPMENT BUILDING PERMIT REVIEW CHECK LIST Address: _it~p~ 39 f"' (~v~. Zoning: - ~ C Existing use: ~tyn Permit is for: _ !$u Deed: Survey: Plot Plan: STANDARDS Required Setbacks/Height: Front: Side: ~C; I _ Side: _ i5' Rear: Structure Height: 3SCoverages: Building Coverage: AOa~p,x, Lot Coverage: Area and Width Lot Area: Lot wiatn: ~aLandscaping Requirements: Landscaping Percentage: 2p°/b Number of Street Trees: \ ~ gp~ Number of Trees/Shrubs: %0 1600 zv Parking Requirements: Reguired Parking Ratio: l(2~ C30_ Number of Spaces: Z~ Number of Handicap: Z Signs: Location Free Standing: h Q,.. Wall: Other: Proposed `4 s , 7,3' 7~3:5'• JU~` f ~.ya/t e ~ .9-` o D Z. Size/Area Lighting shown: ,QKi S.fi,11-5 08/15/06 12:26:49 City of Wheat Ridge Page 1 bp701-ls PFRMIT INFORMATION - 060793 cruo[e PERMIT INFORMATION: Permitq: 060743 Pecmic Cd: Commercial Addition Pexmit D[: 08/15/2006 Expires: 02/11/2009 LAND PARC2L INFORMATION: Zone Cd: RESiden[ia1 SFR Funct Use: Unassigned Subdivision: Unassigned Cont Type: Unassigned Legal: Address: 30901 38TH AV Parcel Cd: U0290 OwNER: noug Saba Addness: 3880 Upham SL. City/S[/2ip: Wheat Ridge, CO 80033 DU: 0 Las[ Zone Dt: Annex Dt: Lot: Block No: 0 JOH DESCRIPTION: Firehouse addi[ion. 2500 sq ft PE85 QTY DUE PAID: No Fees .00 .00 .00 o.oo 0.00 CONTACTS: owner Wheat Ridge Fire Protection Di Doug Saba 3880 Upham St. Wheat Ridge, CO 80033 3039035902 gc CL1 TC2 Inc. Stefanie McXelligo[[ P.O. Box 1018 Evecgreen„ CO 80939 3036900084 sub CLB Grizzly Plumbing Inc Matthew Allsman 15606 E GRAND AV5 AURORA, CO 80015 3036995832 sub CLA G& H Electric Co. 9305 Harlan St Wheat Ridge, CO 80033 3039249200 sub CL9 Westwind Mechanical Susan Tinkey PO Box 1490 Conifer, CO 80433 3039992516 PERMIT NOTES: 08/15/06 CREATEO FROM APPLp 06-0029 09/10/06 crooAOk subject to field inspection. Fire rated sleeping azeas, change HVAC [o meet seperation. 06/19/06 MR: Pexmit approved wi[h 20& landscaping required. New sign will require separate pesmit. 06/19/06 DFB: OK. See attached sheets. 06/12/06 R5: Given to MR for review. -planning K5: Given to CR for review. -bldg RS: Given to OB for review. -PW INSPECTION INFORMATION: pf WH4T APPLICATION FOR MINOR GRADING/FILL PERMIT ° m ctoano° APPLICANTSNAME:Vf V, A'~U- ,~&T_ APPLICANT'S ADDRESS: J(Dai2l . (Indude City, Siete, Zip) ADDRESS OF FILL: S~LYV~ DATE OF APPLICATION: All pemuts shall be applied for through the Public Works Departmenf. An approved persnit is effective for a period of one (1) year from date of issue and may be renewed. All fees shall be in accordance with those fees established by the Uniform Building Code or other applicable City adopted Resolutions or Ordinances. Note: AZZ public improvements, when constructed, sha[I be maintained (by the respective individual(s) and/or campany responsible for the construction of that public and/or private improvement in the respecfive development) on a daily basis, or as needed, such that they are free of mud and other construciion debris tracking from ihe site. Failure to comply with this requirement will resulf in the enforcement ofArticle ZI, Specified Nuisances, Section I5-I6 (4) of the City of Wheat Ridge Code ofLaws. NIINOI2 GRADING, EXCAVATION, AND FILL PERMITS 1. 1-50 Cubic Yards: No permit is required for dumping or excavation of earth materials, which do not exceed 50 cubic yazds, provided, however, that any $11 deposited is on natural tenain of less than three (3) horizontal to one (1) vertical slope, or such fill is less than three (3) feet in depth and is not intended to support permanent siructures, and in addition, such fill orexcavation does not obstruct or otherwise adversely afFect any drainageway. Should any of the above standards be exceeded, or a drainage waX be affected, a pemut shall be required under the guidelines for No. 2. 2. 51-500 Cubic Yards: Dumping or excavation of earth materials not exceeding 500 cubic yazds may be allowed with a permit approved by the City Engineer. All applications aze to be submitted on the appropriate completed application forxn and shall be accompanied by the apptopriate fee and sketch plan indiqating the following information before the pemut will be issued. A. Location and dimensions of all properiy boundaries and structures on the site. B. Location and extent of azeas to be filled and/or excavated. C. Loca$on of existing and proposed drainageways, irrigation ditches, etc., and indicafion of how and where historic run-off will be maintained on and through the site. D. Cross-section azea to be filled ancUorexcavated indicating original slope, new slope and depth of fill. E. Statement that indicates the proposed use or purpose for said fill or excavafion. F. Relarive elevation of adjacent properties. G. Erosion control plan showing placement of control devices such as hay bales, etc. 3. 501-10,000 Cubic Yards: Operations in which earth material fill or excavafion exceeds 500 cubic yazds, but does not exceed 10,000 cubic yazds, may be allowed by a permit issued by the City Engineer after review of an application and supporting information. The following infoxmarion shall be submitted with the required applicarionform: A. A site plan, prepazed and signed by a Colorado registered professional engineer, at a scale of no less than 1 inch to twenly feet (1:20) which illustrates the following: B. Location and dimensions of all property boundaries and structures on the site. C. Location and extent of azeas to be fi11ed and/or excavated. D. Location of existing waterways and drainage courses indicating any changes. (for a site containing an established irrigation ditch, a letter of approval from the appropriate ditch company shall be required). B. Location of existing and proposed points of ingress. F. Location and extent of existing vegetation, proposed changes in such vegetation and methods of rehabilitation on site vegetation after earthwork operations aze complete. G. Erosion control plan. H. Grading plan with existing (dashed lines) and proposed (solid lines) ground contours with contour intervals of 2 feet and spot elevations. I. At least two cross sections (east to west and north to south) through the site showing depth of fill and/or excavation. J. A drainage report may be required if site runoff characteristics aze changed. K. Relative elevations of adjacent properties and shuctures. L. Statement of purpose of intended fill and/or excavation. 4. Performance Standards: The following provisions shall apply to all Minor Grading, Excavation and Fill Permits: A. Rehabilitarion: Within thiriy (30) days after cessafion of filling and/or excavation, rehabIlitaflon for the site shall have been completed in accordance with the approved plans. Rehabilitation shall consist of leveling, grading, landscaping or any combination thereof to minimize potential erosion and be acceptable to the City Engineer. B. Debris: Debris and/or contaurinants shall not be used except with the approval of the City Engineer. "For the purpose of this Section, the term debris shall have the same meaning as the terms "gazbage, trash or junk" as defined in the Wheat t2idge Code of Laws, Section 15-4." In no case shall debris or contaminates idenrified or classified as hazazdous waste by local, state or federal agencies be used as fill in any fill azeas within the City of Wheat Ridge. C. Excavation and/or fill azeas shall be graded to facilitate weed control until final grades aze set and site rehabilitation and use occur (must be leveled with side slopes not to exceed 3 to 1). 1:TORMS&I.E]'LERS\APPS&PERMTfSY✓u'norGMingkFillPamitdoc 2 - Rev2105 5. Permit Fees* 50 cubic yards or less 2 q $23.50 ~ ✓ 51 to 100 cubic yards $37.00 l Olto 1000 cubic yards for the first 100 cy $37.00 plus for each additional 100 cy or fractionthereof ' cy X $17.50/100cy 1001 to 10,000 cubic yazds for the first 1000 cubic yazds $194.50 plus, for each additional 1000 cy or fraction thereof cy X$14.50/1K cy TOTAL ~ p yJ *Wheat Ridge Code of Laws Section 5-76. All pemuts sha11 be applied for prior to fill deposition or excavation operations begin. Any permit applied for after cutting or filling operations on site aze in progtess shall be subject to a double fee and other penalties as prescribed by Wheat Ridge Code of Laws, Section 26-1004. Any fill requested under ttus permit within the 100 year flood zone MLTST COMPLY WITH WHEAT RIDGE CODE OF LAWS, SECTION 26-801, FLOOD PLA1N ZONING ORDINANCE. I HEREBY ACKNOWLEDGE THAT THIS APPLICATION.IS CORRECT AND UNDERSTAND THAT I CANNOT START THIS PROJECT UNTIL THIS APkLICATION IS APYROVED. I SHALL COMPLY WITH THE LAWS OF THE STATE OF COLORADO AND WITH THE ZONING REGULATIONS 11ND BUII,DING CODE OF THE CITY OF WHEAT RIDGE. ANY VIOLATION OF TI3E ABOVE TERMS WILL CAUSE IMMEDIATE REVOCATION OF TFIIS PERNIIT AND COMMENCEMENT OF ENFORCEMENT PROCEEDINGS BY THE CITY OF WHEAT RIDGE. THIS APPROVED PERNIIT WILL BE KEPT IN MY POSSESSION OR PERMANENTLY ON THE JOB SITE. APPLICANT: p plicant's Signature C ~ )zl O er s Sign e if different than e) CITY OF WHEAT RIDGE: F=i>?- ;ity Engineer 61, -7, Approval Date I:~FORMSffiLETIERS\APPS&PERT11'fSWu'oorGnding@FillPamiLdoc 3 Rev2/OS ~~4.fr 1X;;;__ wa1'~., WHEAT RIDGE FIRE PROTECTION DISTRICT PO BOX 507 • 3880 UPHAM STREET • WHEAT RIDGE, COLORADO 800340507 303-403-5900 • FAX303940-0350 • WWW.WRFIRE.ORG TC2 Incorporated i August 1, 2006 P.O. Box 1018 Evergreen, Colorado 80437~~ G Re: Remodel at 10901 West 38h Ave., Wheat Ridge Fire Station 2. The following requirements are made under the 2003 International Fire Code and N.F.P.A. 10 adopted by the Fire Board of the Wheat Ridge Fire Protection District and the City Council of the City of Wheat Ridge, Colorado. Demolition. 1. Plans shall be submitted to the Fire District far the following; • Change orders for the approved submitted pians. _ 2. All construction dumpsters shall be a minimum of 20 feet form any structure. 3. All Fire Lanes shall remain clear of construction vehicles at all times of construction. 4. A required fire extinguisher with a minunum rating of 2A-44BC shall be within 10 feet of aIl "HOT WORK OPERATION". 5. All fire caulldng shall be the depth of the opening. 6. An emergency phone shall be supplied by the General contractor for job site emergencies. 7. All inspections shall be scheduled through the Fire District and the City Building Department. A minimum of 24 Hour notice. 8. Copies of requirements for submittals of sprinklers are attached to this plan review. 9. The Life Safety Code shall be adhered to at all times. (For copies contact me atthe Fire District.) lO.The Fire District shall be notified during all rough-in inspections and final inspection with a 48 hour notice before. An uestions regVhese requirements contact me at the Fire District. DouglasJ. Saba Fire Marshal Fire Code Inspector #5483898-66 ~~~~Ali ~ 0(0' pqo3 oF WHEqT 9 City of Wheat Ridge Building Permit Number: ~ m Community Development Deparfinent Date: lr~Q,lC~~.A:i-.RAF..r./.LJAJ:a .lk'.~[ 11.4~.R~F~.k./:e.S ~OlORPOO .[~:l (.F.lL~.~".~G, PE, RMI.E AP-PLL ~A TIP,: e' Property Owner: ~arP% Property Address: `vqa 1 W, 3~~- Ay, Phone: Contractor License No.: Company: -Iz~2 Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT guildinpDept. Valuafion Figure: $ i hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the Ciry of Wheat Ridge or covenants, easemenis or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this applicafion and that I assume full responsibility for compiiance with the W heat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work underthis permit. Pians subject to field inspection. (OWNER)(CONTRACTOR): SIGNEO DATE (OWNER)(CONTRACTOR):PRINTED DATE V31Ue:$ Permit Fee:$ Plan Review Pee:$ Use TaY: Total:$ Use of Space (description): , Description of wo~~~~ 3 i~Y~77 Sq. Ft. added G BUII.DING DEPARTMENT USE ONLY COMMENTS: ` Approval: Zoning: ~ . )ING COMMENTS: Approval: ~ IC WORKS COMMENTS: Approval: DEPARTMENT COMMENTS: Approval: ;uoancv: Walis: Roof: Stories: Residential Units: Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Expiration Date: ApprovaP Approval: Approval: (1) This permitwas issued in accordance with the provisions setforth in your application and is subjectto the laws ofthe State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or a6andoned for a period of 180 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been orwill be made in the original plans and specificalions and anysuspension or abandonment has notexceeded one (1) year. If changes have been or if suspension or abandonmenl exceeds one (1) year, fuli fees shall be paid for a new permit. (4) No work of any manner shali be done that will change the natural flow of water causing a drainage problem. (5) Contraclor shall notify ihe Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding wilh successive phases of thejob. (6) The issuance of a permit or the approval of drawings and specifications shall not be conslrued to be a permit for, nor an approval of, anyviolation of the provisions ofthe building codes orany other ordinance, law, rule orregulation. All plan review is subject to field inspections. Chief Building . . • _ . Qf WHEqT. . . City of Wheat Ridge Building Permit Number. ~ m Community Development Department Date: . . CpCORP00 ~~s~/.~~~.R~,.E.r. ',.k,C & .t:C.~l"~~`.E.k,.c~..4""/:."-.fX.LC'k~-R.~:.tY . . 1.-►-~ILDINGX'"E1kWTAPPL.[F.~..~.F.',RON . Property Owner: Property Address: Phone: Contractox License No.: : Company: TG2 Phone: OWNERICONTRACTOR SIGNATURE OF UNDERSTANDMG AND AGREEMENT I. Buildinp Dept. Valuafion Figure: $ I hereby certify that the setback distances proposed by this permit application areaccurate, and do not violate applicable ordinances, rules or regulattons of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements . shown, and allegations made are acwrate; that I have read and agree to abide by all . conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all oiherapplicable Wheat . Ridge Ordinances, forwork under this permit. Plans subjectto field inspectioa . (OWNER)(CONTRACTOR): SIGNED DATE (OWNER)(CONTR4CTOR):PRINTED ' DATE . V2.IU0:$ Permit Fee:$ Plan Review Pee:$ Use Tax: TOY21: $ Use of Space (description): , Descriptionofwork:~~~t -3 Sq. Ft. added ~ ] ~ ONWGCOMMENTS: ~ ~ ~ ~ . Approval: . . ~ . ~ Zoning~ Approval: DEPARTMENT USE ONLY BUILDINGCOMMENTS: - ~ . APprovaL•~ PUBLIC WORKS COMMENTS Approval: ~ ~ . IRE DEPARTMENT COMMENTS ~ Walls: Roof: SIC: Sq.Ft.: Stories: Residential Units: Electrical License No: Plumbing License No: Mechanical License Na Company: Company. Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This permit was issued in accordance with ihe provisions set fodh in your application and is subject to the laws of the State of . Colorado and to the Zoning Regulaiions and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of . . ' Yhe Ciry. . . . . . . . ..(2) This permit shaii expire if (A) the work authorized is notcommenced within sixty (60) days from issue date or (B) the building . authorized is suspended or abandoned for a period of'I80 days: - : (3) If this permit expires, a new permit maybe acquired fo(afee of one-haifthe amount normallyrequired, provided no changes . havebeenorwillbemadeintheoriginalplansandspecificationsandanysuspensionorabandonmenthasnotexceededone . . . (1) yeac If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit . .(4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. . .(5) Contractor shall notify the Building. Inspector iwenty-four (24) hours in advance for all inspections andshall receive written : . approval on inspection card befoie proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construedto be a permit for noran approval of, anyviolation of the provisions of the building codes or any other ordinance, law, rule orregulation. All plan review is subject to field inspectiona r . ' . . . Chief Building Official I Sent. By: Zeiler-Pennock; 3034553708; Aug-30-06 10:47AM; Page 2/2 )N;EA -PENtlJtI 15t 1NIA~' 1!II:l~. :fl'a93 [i' a~il: A? August 30, 2006 cts Arch Engineers City of Wheat Ridge Community Development Department 7500 West 29'h Avenue Wheat Ridge, CO 80033 Attn: Chadley Root Code Administrator Re: Wheat Ridge Fire 5tation #2 10901 West 38~' Avenue Permit No. 060743 Chad: The foliowing comments are in response to redlined review notes dated July 10, 2006, on the construction drawings. Reinforcing in Footings: The 245 cnntinuous rebar in the bottom of the wall have been relocated to the footings with a 3" minimum clearance. 2. Vapor Barrier Under Slab: The vapor barrier is installed to prevent moisture intrusion for sheet vinyl floor finish. In this project there is no sheet vinyl. Vapor barriers force the moisture in the fresh concrete to escape only from the top forcing higher tensile stresses from shrinkage resulting in curling and additional cracks to occur. We recommend the vapor barrier be omitted for this project. 3. Gravel Layer: The gravel layer has been omitted to prevent attraction of water to the area below the slab. In discussion with A.G. Wassenaar and Associates, geotechnical engineers testing the soils, the gravei layer is not required. Consequently, we recommend the gravel layer not be installed. If you have any questions regarding this submittal, please call me. RespectFuliy Submitted, ~ Paul R. Pennock, P.E. PPincipal Zeiler-Pennock, Inc. PRPlmkl August 30, 2006 City of Wheat Ridge Community Development Department 7500 West 29`h Avenue Wheat Ridge, CO 80033 Attn: Chadley Root Code Administrator Re: Wheat Ridge Fire Station #2 10901 West 381h Avenue Permit No. 060743 Chad: AM& ~Architects ~ ~Engineers 1EItEP - PENNOCR.INC. 2121 Barnai SiaE[1 SuNF fi00 4 [xr[w. [0 80211 307 4S5 7322 7 301 VSS 1708 f www.ttiL tAr[uxo[K [au The following comments are in response to redlined review notes dated July 10, 2006, on the construction drawings. Reinforcing in Footings: The 245 continuous rebar in the bottom of the wall have been relocated to the footings with a 3" minimum clearance. 2. Vapor Barrier Under Slab: The vapor barrier is installed to prevent moisture intrusion for sheet vinyl fioor finish. In this project there is no sheet vinyl. Vapor barriers force the moisture in the fresh concrete to escape only from the top forcing higher tensile stresses from shrinkage resulting in curling and additional cracks to occur. We recommend the vapor barrier be omitted for this project. 3. Gravel Layer: The gravel layer has been omitted to prevent attraction of water to the area below the slab. In discussion with A.G. Wassenaar and Associates, geotechnical engineers testing the soils, the gravel layer is not required. Consequently, we recommend the gravel layer not be installed. If you have any questions regarding this submittal, please call me. Respectfully Submitted, ~ Paul R. Pennock, P.E. Principal Zeiler-Pennock, Inc. PRP/mkl September 7, 2006 City of Wheat Ridge Building Department 7500 West 291h Avenue Wheat Ridge, CO 80033 Attn: Chad Root Building Official Re: Wheat Ridge Fire Station #2 Dear Chad: Architects ~ ~ Engineers 7EREP - PENNOCN.ING 2127 BarA wi Sia6[i Suii[ 600 D [av[a. f0 80211 703 4SS 3322 I 703 4SS 370B f w ww iEii[apEawo[k cou In response to your redlined comments on the drawings dated June 5, 2006, we respond as follows: Sheet SP1.1 • The light poles redlined to be downcast are existing and are downcast. • The handicapped signs at each handicapped parking space will be installed per redlined note. Sheet A1.1 • The main lobby door and Workout Room exit door will be equipped with panic hardware as redlined. • An occupant load sign will be installed in the Training Room as redlined. • The double doors leading out of Training Room into the hallway were redlined to swing into Training Room. These are existing doors and were verbally approved by you on August 27, 2006 to remain as installed. • The water fountain redlined to be ADA accessible is existing and generally complies with accessibility standards. • The interior walls redlined to be one-hour will be protected with 2 layers of 5/a" "x" gypsum board on one side as verbally approved by you on August 28, 2006. • The 20-minute door separation as redlined in the hall between the Day Room and the Trsinirg Rccm will be provided by reworking the existing exiYdocr zssemb!y as verba!!r approved by you on September 7, 2006 and indicated on the attached drawing. The existing door will be changed to a rated 20-minute solid core wood door with a magnetic hold-open activated by the new smoke detection system. The sidelights as well as the adjacent glazed light into the Office/Bedroom on the Day Room side will be changed to'/<" wire glass. • Exit signs as redlined at the Workout Room doors are provided for on Sheet E3. • The new clothes dryer as redlined to be vented is so specified on Sheet M1. + The water heater redlined to be provided with make-up air is existing and so provided. • The requirement for fire alarm and smoke detectors redlined on the sleeping rooms will be sc provided. • The new toilet rooms redlined to be ADA accessible are so designed. • The redlined requirement for an R-21 exterior wall been met with the wall assembly as designed. Wheat Ridge Fire Station #2 September 7, 2006 Page 2 Sheet A1.3 • The roof top unit redlined as requiring a guardrail is not at the edge of the roof. The sloping roof to the west of the unit is several feet above the new flat roof. Sheet A2.1 • In accordance with redline comment, tempered glass will be installed adjacent to doors and walking surface in accordance with the IBC 2003. Sheet A3.1 • Perimeter insulation, as redlined, will be installed with a minimum R-7.5. = Exterior wall assembly, as redlinEd, is curren4ly designed For a minimum R-21. • Roof insulation, as redlined, will be increased to achieve a minimum R-38. Sheet A4.1 • The two #5 bars in the bottom of the grade beam wiil be relocated into the footing as requested in the redlines. Structurally, the location of these bars serve as well in the footing. • As described in our letter dated August 30, 2006, the redlined note requesting 6 mil. vapor barrier and gravel under the slab is not recommended by our office because of the reasons noted therein. We are assuming this is acceptable to your department. Sheet M1 • With regard to the redlined note requesting that the existing bedroom be added to the supply side of the new rooftop unit, this is an existing room and already is supplied from an existing RTU. Sheet E3 • In accordance with the redlines, emergency lighting has been added to the Day Room and Bedrooms per the attached drawing. Should any of these comments be of concern, please contact me as soon as possible as construction is proceeding. Sincsrely W • - W. Kelly Oliver, IA Architect Zeiler-Pennock, Inc. WKO/mkl COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 16092 BUILDING INSPECTION LINE -(303-234-5933) Date : 8/19/2003 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: WHEAT RIDGE FIRE DEPT. Property Address : 10901 W 38TH AVE Phone : 403-5900 Contractor License No. : 18061 Company : Wilson Brothers, Inc. Phone : 294 9535 ' OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certiTy that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read nd agre ae ' y all conditions printed on this application, and that I assume full e n' i ity r p'ance w'th the W eat Ridge B ildin Code (U.B.C.) and all other appli abl t g ord~; s, or wor nder this pe mit. (OWNER)(CONTRACTOR)SI ED DATE 9 Construction Value : $6,500.00 Permit Fee : Plan Review Fee : $0.00 Use Tax : $0.00 Total: $0.00 Use : Description : REMOVE LOOSE GRAVEL FROM SOUTHWEST FLAT ROOF, INSTALL 112" R-BOARDOVER EXISTING ROOF, INSTALL 21 SQ. WHITE MODIFIED MATERIAL OVER ASE SHEETING BUILDING DEPARTMENT USE ONLY - SIC : Sq. Ft. : -~,N~~~_;~Co me''nts:+ Zon'i Approval : Zoning : Building Com'"ments,; Approval : Public Works Comments~ Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Company: Expiration Date : Approval: Plumbing License No : Company : Expiration Date : Approval: Mechanical License No : Company : Expiration Date : Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Coloredo and to ihe Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within si>1y (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 720 days. (3) If this permit expires, a new pertnit may be acquired for a fee of one-half the amount normally required, provided no changes have been orwill be made in the original pians and specifcations and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done thatwill change the natural flow of water causing a drdinage problem. (5) Contractor shall notify the Building inspedor hventy-four (24) hours in advance for all inspections and shall receive written approval on inspection card 6efore prxeediing with successive phases of the job. (6) issuance of permit or the approval of drewings and specifcations shall not be constmed to be a pertnit for, nor an approval of, anyviolation of the ro is $ uilding codes or any other ordinance; law, mle or regulatioa Chief Buil ' g lnspector 46 Please sign Terms and Conditions on reverse side of page. COD'IMUA'ITY DEVELOPMENT DEPARTMENT Building Pemvt A'umber: w"ES BUILDING INSPECTION LINE - 303-234-5933 Date: CITY OF WHEAT RIDGE U m 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) OR P00 y y APPLI~/i lfATy¢~ 31~4 Y Proper[y Owner: ro+t~eo' q~,~ 563 -03'^39X Property Address: lvr/Ol A~/ i , ~-t'""`~ Phone :2 Contractor License No.: /&XO i Company: 0WNER/CON7RAC70R SIGnANRE OF UNDERSTAnDIRG AND AGREHMFNT 1 hereby certify that the setback disiances proposed by [his pertnit application are accuate, and do noi violate applicable ordinances, mies or regulations of the Ciry of Wheat Ridge or covenanis, easemenis orrestrictions of record; that all measuremenu sho.Nm, and allegations made are accunte; thal 1 have read and agee to abide by all conditions printed on this application and that I assume full responsibiliry for compliance with the Wheat Ridge IIuilp ng Code (U.B.C) and all otVjFr'applic Ridge Ordina ~ es, for work under this ermiL ~ ~ Construction Value:$ Permit Fee:$ Plan Review FeeS Use Tax:$ TOL3l:$ lco5~c / / ~~n"•, - ~ SQ'(~WiJ'r /CCA C./ Ic1 llESCRIPTION: ~`"lQ~/ BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENT3: Approval: Occupancy: Walls: Roof: Stories: Residential Uniu: Elech-ical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expirarion Date: Expira6on Date: Approval: Approval: Approval: (1) This yamil was issued in accordance witfi ihe pro~dsions stt forth in your applicabon and is wbject m the laws of Ihe Sw1e ofColorzdo and lo the 7Aning ReguWtions and Building Codes of N'heat Ridgc, Colorado or my otM1er applicable oNirtantts of the City. (2) T hispermitshallexpircif(A)theworkauthorizedisno[comm<ncedwithinsixry(b0)daysfiomissucdatwr(0)U¢buildingaulhorizedissuspandcdor abandoned fw a pmod of 120 days. ' (3) If this pmmit expira. a n<w yermit may be a<quired tor a k< of one-half the amowt nonnally requircd, pmvidcd no changa have bcen or xi11 be made in the origiml plans and specificauons aod any susprnsion or abmdonmrnt haz not excttdcd one (I) year. 1f chang<s havc been or if susyension or abandonmmt excads one (1) yrar. Cu0 fxs sM1all be paid fon oew pennil. ' _ . . _ . . . . . . . . .(a) Na wodk of any manner shall be done ihat will change the namral tlow otwam cSusing a dninage ym6lem. (5) Contracar shatl notify the Buitding Lispector twenry-fow (24) hours in advance for all inspecoons and sAall receive wrinrn appmral on insyecfion <ard betorc proceeding with successive pLases of the job. (6) The issuance ot e pennit or the aDProval of drawings and spccificauoas shall not be conswed to be a pertnit for, nor m approval of, any.iolauon of the pmvisions of the building codcs or any other ordinance, law, rulc or rcgulauon. Chief Building Inspecror DEPARTMENT OF PLANNWG AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE - 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number : 11594 Date : 12/12/2000 Property Owner : LJ K Fv~c '5"i~~ 6yl 4:" z Properry Address : 10901 W. 38TH AVE Phone : 403-5903 Contractor License No. : 20126 Company : Timberline Exteriors Phone : 303-655-1644 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE Construction Value : $0.00 Permit Fee : Plan Review Fee : $0.00 Use Tax : $0.00 Total: $0.00 Use: Description: GUTTERREPLACEMENT Electrical License No : Company : Plumbing License No : Company : Mechanical License No : Company : Expiration Date : Expiration Date : Expiration Date : Approvab; Approval : Approval : (1) . This permit was issued in accordance with the pmvisions setforth in yopur application and is subjec[ to [he laws of the Sta[e of Colorado antl to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of fhe City. (2) This pertnit shall expire if (A) fhe work authorized is not commenced within siaTy (60) tlays from issue date or (e) the building authorized is suspended or abandoned for a period of 720 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normaliy required, provitletl no changes have been orwill be made in the original plans and specifications and any suspension or abandonment has no[ exceeded one (1) year. If changes are made or if suspension or abandonment exceetls one (1) year, full fees shall be paid for a new permit (4) No work of any manner shall be done that will change the natural flow of wa[er causing a drainage problem. (5) Contractor shall notiry the euilding Inspector twenty-four (24) hours in atlvance for all inspections and shall receive written approval on inspection cartl before proceediing with successive phases of the job. (6) The i a ce of a permit or the approval of drawings and specifications shall not be cons[rued to be a permit for, nor an approval oF, any violation of the pmvisions u' i any other ordinance, law, rule or regulatioa e Chief Buildin - nspector PROPOSAL ('SS"/,~~ y-3 F4y ~ TIM3E(tLInE EXTERIORS 6355 PLEASE HAVE EXTERIOR "Today's Technology...With O'I Time Craftsmanship" JOB # ELECTRICAL POWER Jim Perry, Owner AVAILABLE 17743 WCR 6' Brighton CO 80601 P.O. # (303) 655-1644 Date Name L) ( S i Home Phone Billing Address 1 nqD ( [ A), 3 g4i. A v Work Phone City 2t p~z , State Zip ~(po ~ -z_ Cell Phone Job Name Job Address_ Contact Person K~ L-\,/ Pager Fax rn \ hL~ hone E-Mail Web We hereby submi[ speciFciations and esti [es, subjec[ to all tertns and c tions as se[ forth No,s GUTTERS 03 Z SIDING M STYLE J3✓ 6COL BAAiD N TYPE STYLE GOLOR AO PI n I~O S ST RY ~Cr,TH 8 ✓ '4 TOTAL AE F OTAGE $ _ ROO PI CH ROOF E STORY LEN ' SOFFIT (X. FACIA ROOFPITCH ROOFSTYLE STORY LEN $ ✓ F LY COLOA LENGTH $ . CORNERS $ F ONLY COLOR LENGTH 90° / ODD ANGLE / COMP / REMOVE & HAUL EXISTING GUTT. $ S SO IT & FACIA COLO GT. YE NO ❑ LENG V / O SP S IN A F3N 7YPE S E ~ C . OR TYPE SIZE FObTAG i S 1 ST~ Y 2 STORY LEIVGT~H TIP UPS $ r % T 1 RE OVE & HAUL EXISTING OWN $ STYLE SIZE OR # $ YES NO ❑ ENGT ~ 7~ HO K UP EXIST[NG DOWNSP UCS S # itLM ' ~ LAS Tn'E $ TYPE ST YLE COLOR I ENGTH ,y I,D BUILDING PERMIT (when xeyuirea) V t OTHER OTHER $ OT[-~'.R R ~ WeaccePt SUB TOTAL We a pt =AL TOTAL DUE UPON DAY OF COMPLETION cRArvnr T $3~$' ✓ A uthori i t e Date NOTE: This proposal may be rthdrawn by us if not accepted within ays. ACCEPTED: The above prices, specifica- i~- tions and wndifions are satisfactory and S Uba[e hereby accepted. You are authorized to do OU . [he work as specified. Paymen[ will be made as ouNined above. ,~q .va ~~>-s~ a y , BUILDING DEPARTMENT (303) 235-2855 CITY OF WHEAT RIDGE * * Correction Notice Job Located at 5 ~ o~ I have this day inspected this structure and these premises and have found the following violations of City and/or State laws gov- erning same: You are hereby notified to correct the foregoing violations. When corrections have been made, call for inspection. Date DO NOT REMOVE THIS TAG for Building Dept. FORM WR6-22 _ 3 ? a o s ~ > > ~ ~ m p - ° n ~o i o n u o v o- ° o ~ n - y5<° ~ fl o = ° ~ ~ ~ ~ c a'o E o o. Q O Q N 4 O 6 6 \ ~ o - 0 c° o m o F M m~ ~ u u-~I d O O 3 o~ 0 ~ a w ~a E - ' z v ° 3 u. n . ° ' o - ~ N n m 71 ou r O p uci m D m 3 r D x -n m m m m ) m ~ n ~ O x n ~ 0 ;1 ~ ~ . n TI 2 9 C D y N r m C) DN Z) j Z ~ N Z 0 m . \ _ ~o -i ~ n r ~ _ r ( ~ N W n 11 O ~ C 0 0 Z a ~ x 1 ~ m ~ = m m z ~ m ~ 0 D 2 y ~ -1 [ f D S n N Z ~ 0 m < p ~ Z m f ~l ~ ~ fl r rTi 0 y D O y ]1 ~ 0 tn ~ m m 2 n m Z m m A A - p N ~ N m 0 m m ~ ~ v p f ~ ~ ~ ~ c m 1 i m ~ m O D 0 31 p n n ~ m JpC (m] ~ N N V ~ m R7 T 0 m ~ ~n (n r x 3 m y N f~ r ~ ~ n D r ~ ~ O N C ~1 O D ~ f D 47 A N Z N m F N ~G 1 '~1 m S F Z ~ S i - s O ~ g ~ N D O f D ~ ~ ~ ~ m A ~ 1 D Jc 31 D fn x p N Z m m iy m c z A m ~ -i °-0 ~ m r m ~ ~ m ry) y C N ; i ID o Z C) ~ m m N ~ z O ~ W O A ~ x O m n ~ .a ~ o n ~n ~ o < o a ' n m p n i ~ c) ~ ~ D ~ c a ? n o m ? D w s y~ Z 1 ~ p p ~ 2 Z T D Z g r ~ m m ~ m m m C C C ~ m ~ R O 0 S = NE D D O ~ ~ 00 ~ om ti N Z D ~ ~ A :E v v ; ~ r a U y -i co ~ Z * cm~(7 m ~ O D r ~ Z D m m ~ N Z " a O mm` ~r='m 9 T v m O ~ o-y DL~ Z O -1 ~ x i L no.o N m m r ; O Z ~ y 3 W ~ 2 ~ om~ no \ m o r m m n O N ~mm y ~ 0 C m ~ ~A ~ m > N m O D Z T Z ~ O v o ~ a ~ ~ p ~ p m 'b F, z C7 v O D D ~ ~ °n 2 z D y m MO ~ N m z > O omr z ?m M m Z m no ~ ~ = s ~M K N mZ y y 9 = m ^ O ~ 0 ti 0 z N. X ,Q~ J~ x ~ W ~ ~ ~ m£ C~ m N x G N= C 02 L y 02 mf 1 m m Z £ N cm T mm oz 0 m z 0 m 0 m ~ ~ ~ ~ C A m Lt G i> V 1 i n m ~ ~ ~ < r m N ~ =°~Z~ O m y Z { m 7~p > 0 y m m C~ Z ( i~ 0 p ~ m JJ y W N r W 10 ~ A W N r N~ Vl T~ y N r ^ ~ m m m; m m > -.D > n A z r z~ r 4s C o ~ o O N T v x Z s O o V \ 0 ?o o ~ot o , a z m i m ❑ ° ~ ~ ~ r N r, < i ~ , < ? r I~tl ~ m m Z p nl o o ❑ m m ~ ~ 2 S 2u, Z ^ \ ~ ~ 0 r 0 \ ~ . o 0 0~ N ~ ~ 0 m m ~ o r ~ o~ ' C) n P D 0 v D ~ F £ ~ = 0 ❑I o ' 1 I; 01~' ° ~ m 7~17 D Z m ~ Z m a m N ~ y O \ I ~ ~ Y o m o o ~ N ~ ~i ~ o n . a z~ e m N ~ ~ G I a ° v ~ O ~ ° ° ° 2 ° T g h1 v o g o . o ~ ~ g y 0 ~ • o „ C s ~ « s R o ~ N ~ : ~ 0 O ~ m O I r i ' N V I A O w N ~ ~ p ou ~ 0 ~ rnm m Z C m m m ~ m C ~ v Z ~ ~I~ ~ m ~ n CO ~ -i r- r^ ' <OZ ' O~~ ' SZp I m~~ ~-iZ I mZ ~ . 0 oc m I Q-~ I ~~r 00 z~ ~ m Z ~ I -0 m ~ 3 1 ~ I --I ~ Z 0 ~ W ~ co V ~ ~ L ~ _{'O p r ~ F ' : : ~ i i " ~ - ; i . . ~ N : . ' : : ~ • • ~ \ ' ' . ' _ ] ~ . . i - ~ ~ f . ~ i ~ ~ _ . ~ a : •I~ Cli LY'.:: ~ b' W ` I ~ t` • f, < " ~ r - ~ ~ ~i ~ 2;>: r • < G orrr \ ~ 1 ! rf ~ 1 p M1 ~ i ~ r ~ i ~ ~ ~"~C , ~ ~;X~? . - ~ m L1 + i's~ 'v? ~4n s'ya~£ r Yx My r _.1 _ ~ ft 0 ~r e ~ „7 -i j ~ v~•y _ - Ir : V . ` r ~ Y~ ~r ;r ,ti ~y • •',v 'r:: - ~ O . ~'s't,,. ~ {f. - ~i;'~4;:r+;'.<5:•r,.'r ~}'X.~`•r+f,{~ ; f ~ : / f T :z. , - ` ~ F~~_r.,.,.?;q~ ~ ;+j•". ~i ' ~ ~,/F"~.:ii%%~i ; } - t 9~ i " ~ ;`~`>;:,..:v.: t P ~ ° ' _ ~r ` ! .'8# k d~ . ~ ~ P ~ : . ~ ~ . . . . , , . ~ r . • '~YY `~.a^ .g's_ = ~ - ' _ r: .yy ~ F i Yt. k . ~ _ .s ~ y~' ^z~~~~''' ~S.~L ~g~n"~ °,y S • y~ }~''~f 'r'E'e la ~ ~ . ~ - F;vs~ _ ~tv: - ,~d`~ ~ ; ~'~'-j;~ {~3 °q, ~ v .;•'~°~'a~--,. ` t;'.~``• f~ ` -e '-:-~`Y`~ a, .`2.s ~ F ~(~";-e,:. ~ ex.r, y~ • ~ . f' N . . . _ . _ V ~ . . ~ C.- . . . . . .Ro.,.i .~.W . . . , . . . . . ~ , r ~ ti , : . ~ . ~ ~ ~ ~ . . . . . . . ~ ~ . . ~ . . ...~d~~~, ~ ~ . ~ ~ . . . . ~ . . . 'C"v~...,., . . . . . . . . . . . . . . . . . ~ . ~ ~ . . . . . . . . . . . . . . ~ ~ . . . . . . . . ' . . ~Y1~i. . . . . , . . ~ . . . ~ . ~ ~ . . . . ' ~ . . . . . ~ . . . . . . ~ ~ . . . . ~ 3'.. ~ ~ ~ O ~ . . . . . "k~~ ~ ~ . ~ ~ 4 / . . . , i . ~g~~ P," 'Ry~. ~ . . g.:. . ~ ~ ~ . . ~ ~ ~ . ~ ~ ~ii , r3 ~tii~ Gj Efj ~ ~ ~ td r1' ' ~ ,~1 ~a~. Q •~i ~ { t~ ~it; ~ ~i ~a ~ ' r~t ~t ` z ~ ~ < ~ , G~ ~ i-~, +~7 4~ CU r ~ U~ td t~ • ~ tlf a)s E~ ,~i ,~S ; (1 Qd- ~ ~ :Vl,s, ~ ' ~ ~ GJ rC~` ~I' " : 't~ :47 .r, "`e, U O fU ~ Q$ e_° ~ ~ ; ~ ; GC; N ~C ~ `F~ ~r~ +r•i ~ ~l e~v~ : . ~i ~ * €~t , ' , Lj ~ ~ • ~ r ~ ~ ' ~ `H N ~ ~ ~~`~'tj 4-r~' ~ ~ ~ . ~ . ~ p~..~ ~ ~ .r~ . , ~ ~i f~l ~ , "~'a ~ : Q) ~-1 k..,~-.. ' Q f'.-! . ~ l~i r' ~ S' a) ~ O ~ ~ Q r-3 "~3 rG ~r' d-~'.r, : ^I`~ F' ~ ~ Q Q t~ r-, 4 ~ 4- 6~ ~L' ~ , . ~ `~i ~ ~-r ~'i ~ ~ cX L~ ,ri U ~ ' : k~ ~ (3,~ Q~ ~ C ~ t;' U - ~ ..H Fr~ ' 4= S~r 4~ ~i Q, N r-t ~ _ _ ~ ~tl~~ ~ A~^~~ . ~ t~ : ~ ~ N ~ ~ t~ ~ t~ ; ~ ~ ~ ~ ~ ~ r~2- ~.;n ~ . L„ ~ Q .;..,~{.~i ~4~: !~r,..tr ^el~ . ~ C~' f{~ ~ rE~4~ ri~ ~ . ~ . ~.L~ ~ .~.7~'! {~v r4 ~i . ~+Pi ~ r~ ~ f-~ •n y~>, ~ ~ ~ ~ ~ Q> G~ -F~ ~ , ~'Cj + ~.'L G5 t _ t ~ ~ ~ ; Y~" ~ t~i S~ ~3. Ul ~y t~ ~ ~ ~ j . . ~ RfV~ ~ ~ ~ VJ C~~ 4U i.W~~.~ ~ ,~r~ ~ ~(~I L. ~ ~ 1~ s ,A~~,,.. ~ ~ ~ . ti^{ k+ ~ ~Ui ~ ~ ~ ~ ;~-d ° q? ~i-' ~/l ~ ~ •n ~r{ ~ ~ r~1 ~~i , ~ _ _ ~ ~ ~ ~1 P't N L~ ~1-' .S EI5 •n 't.~ r~ ~i ~ - , - l O1 , ~ ~ ~ ~ _ z - i ~ ~ ~ ~r a~ ~t a~ a~ a~ ~ z~ w Q ~ ~ A ,fl ~1 d~ u3 ~ ~ c~ A ~ ~ ' ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ r~ ~ , ~ ~ . ~ . , . , _ m.,.~. _ ~ ~ 9 _ ~ ~ ~i ~ - ~ ~i u ~ , ~ - . C u~-~ i' ~ ~ ~ ~ Cl ~ ~ { ~ ~ ~ , ~ - - ~ - .~.,,..~,._,...d.,~,,a... ,.~~,,.~,....a~.,.,a,...,.~.w......~ ~ (17 ~ , ' ~ ~ ~ Q Q ~ J c1~ O , ~ ~ a ~ d a ~ ~ ~ ~ , , r r 1-- - t. t " L~. ' i - ~ Q w....~ CL O W _ 4 : ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Q : L~ ~ ` ~ ~ ~ ~ Q C~ ~ ~ ~~,.,,._w._.~~._ f ~ ~ ..w,,.._._. - - - Z d' _ ~ _ i - ~ ~ . ~ ~ ~ w ~ ,6. ~ . , , _ ~ _ ~ ~ , ~ _ ~ ~ ~ ~ _ ~ , ~ ~ I - i ~ ~ i ~ W ~ U t 7 ~ _ i i O ~ ~ ~ ~ ~ ~ ~ c- - ~ w - ~ J` C--~ ~ ~ I I ~ CfJ ~ Z ~ ~ ~ ~ - ! ~ 0-91 0~ 0-~~ ~ -I ~ 0 „,Z M~ ~ ~ ' ? z ~ ~ ~ ~ . ~ _ . 4 -_._.._n ...-m«..,m_.,...-.,.,-A....~.»~.~..,+ . ~ 3 . . . . rs ~ ! . ~ ~ ~ ~ I ~ , ~ \J a ~ ~ ~.......e...,..~. . ...........~-.a..~.=-..-.. . _ _ _ . ~ ~ •r ~ ~ ~ . . a e ~ , ~ ; .TM _ ~ ► f f ~ _ , - - ~ x 7 ~ ~ ~ ' t i ~ ! ~ I ~ I ~ . , ~ - ~ ~ ~ i ~ ~ ~ J ! ; ~ . ~ ~ J . 1 ~ ~ K ~ ~ ~ ~ ~ - I ~ ~ _ ~ p ~ f ~ S w., 1_1__ ~ ~ ~ ( ~ , - ~ -~-.~-.,.-.~^--~,...e.--.-..-. _ _r....,~. , . - ~ ~ ~ , ! A ___~.M_~,m_.____,..,~ . ~ r ~ ~.~....~~,.--__.~-...~.a--_...,a_. , r~ ` _ ~L ~ . ~ .w~ ~f~ P~ ~ ; . „ , ~ ~ v. x~ ~ ' - ~.a ° g ~ ~,~z ; , _ „ ~ e`. _ ~ ~ur _P ~ --R-~- ~ , r-- _ ~ , _ _ ~ ~ ' i Cf. , , ~ ~ . ~ , . _ . n ~ ~ ~ ~ ~ , . ~ . J ~ . . . . . ~ . , . . . . . _ . : , : ! ' . . , , : i~~. , : . ~ ~ ~ ~ i . . ~ . ~ ~ . . . r- ° . ~ . . . . . . i . . ~ . . , - K ~ . . ~ . . ( W ~ . . . ~ ~ . ~ ~ . . ~ ; ~ i . _ ~ r. ~ _ ~ " ( ~ Vt ~ / P. ~ . . ~ ~ ~ ~ ( ti ~ ~ ~F ~ _ i _V.. tI` , a ~ _ ~ _ ~ ~~o , ~ ~ _ ~ ~ d ~ ~ _ ~ ~ ~ - - ~ ~ ' i ( i ~ ~ i s ~ ~ ~ 'r d ~ ~ ` ~ ~ ~ g~ ~ ♦ _ ~ ~ ( J ~ ~ ~ ~ U_ ~ ~ -'Z \.J ~ . . . . y . , . - . . ~ ~ . . Q i~ N ~ . :,.~...~,r~ ~ --,...>...-a«~-..~..--~. . . V ~ _ ~ ~ J ~ ~ ~ ; ~ - I- r.. , . _ . . ~ _._,.~.P ~ , ~ Q y~ . ~ u~ ~ ~ ~ ~ ~ " ~ ° T O ~D Ct; ~1 V ~ ~ ~ .~.2r~ . . ~ :~~u. s „ _ _ _ X ~ ~ « r Y . I ~ - - ' N z ~ - ~ ; ' ~ , - ~ X ; ~ f ~ ~ . ~ ~ ~ . . . . . . . ~ , ~ ~ , , . j 1 • % ~ % ~ ~ / ! _ _ ~ - 9-Z ~ ~~Z ~ r~~ , ~ u ~ , ~ ~ - ~ i ~ , ~ ~ ~ ~ ; ~ ~ ' ~ ~ ~ ! ~ I _ _ ~ ` ~ ~ ~ ~ I ~ , „0 l 01 „0 - ,Z l ~ ~ ~ ~ I ~ ~ . ~ ~ ~ ~ ; ~ ~ ;t ~ f'~ ~ € ~ ~ ; ~ ~ ~ ~ i ~ r ~ ~ i Q f ~ ~ ( + . ~ ~ , , ~ , ~ 1 ~ ~ ~ ~ t i - ~ ; 'f F/ ~ I ~ ~ ~ ; ~ ~ ~ ~ ' I _ ! ~ ' C~ ~ , E ~ 1 ~ r; . , ~ € . ~r ,.a ; - ZE ~ s ~ r ~ , r , ~ . , ~ m~ . ~ ' ~ ,.s,,., ~ ~ ~a,~~w.~~~~A~ ~~„~~~,~,x,~ , ~ ~ ~ - 4 N...,._ 9 3 - ~ ~ ~ ~ ~ i 1 ~ C i , t ~ ~ ~ ~ ~ ~ Y j - ~ i ~ «~o,n-., _ ~r.~ _ e...~.. i i z ~ ~ ~ ~ ~ r.~.e-~-,~.,,.~,.-a~.....,.~,w, ~e..-,.,~,,.~...,~~...~.~ ,.n..~..,.,.,. „ . ~ , ~ . . i . E ~ ~ ~ k ; ~ fa; ~ , , ~t~-. , ~ ~ t ~ Q_ ~ 1 + . .a~~.,A I 1 t ` , c~ - a o ~ ~l S f" ~i (r' ~ ~ , , 4 , ~ t., , . ~ ~ r ~ - ~ _ ._.T.~. ~ ~ ; ~t ~ f d ~ , r ~ - : ~ . ~ ~ , o ' ~ , ~ ~ ~ _I ~ ~i ~ , , ~ ~ ~ a 4 ~ ; , , ~ ~ ~ ~ ` ~ ~n [~1 c~ w o~ ~ ~ r ~ ~ ~ ~ ~ _ E i ~ " ~ ~ ~ t ~ - I ~ ( ' ~ ~ i ~ "1 ' ~ , Q, L~x U s t ' ~ U! l ~ E ~ " ~ ~ C~; l.l.. Q F ~ i S ~ F { i ~ L-~ N ~ _ ~ i ' I Q, i ~ s - W ~ Z h°- i ~ ~ - ~ - _ ~ ~ ~ - ~l o ~ ~ ~ , ~ , ~ - a ~ s ~ ; '4 Cr f ~ ~ _ ~ f ~ _ ~ ~ Q i ' E.._ - ~ U L~ Q n 3 ~ ^ ~ Q ~'1 l~ Z; ~ z ~ ~ ~ Oj _ 1 p ~ ~ x : ~ ~ ~ - ~ ~ ~ ~ . ~ ~ Z ~ ~ - W ~ _ C - _ t__~_ j U ~``t ~ ~ ~ ~ . ~ ~ , ~ . ~1 . . ~ _ ~ ( _ (J ~ ~ ~ - _ , O C.~ ~ ~ ~ ~ I t c~ i ; I ~ . , I I ` ~ a " l J ~i , ` ; ,,a ~ ~ , ~ - F-- c~ - w ~ t, ' , ' I r ` ~ ~ j ~ ; ~ ~ ~ ; ~ ~ ~ ~ , , z ~ , ' E \ i , , ~ Y__.___ ~ o ~mP.~..~._~...,~~~.....~ ~ a` ~ ~ , y , Jl ~ ~ ~ f ' . ~ ~i ~ ~ ! . 0 ~aP_~..~ .~.;~_..n~....w:.__..____rv~,~.,,. _ .r .Ywa_. „ ; , I , ~ ,~..._...,...~._:.,_W.~ ~W.,_.~,_,~~.m..~.. .r.__ ~ , m~..~,~.x...,,~,.~~..w .~m.~..~~. ~~a _ , U ~ , F--, Ll...' a, _ , ~ - - _ . ,9 - , ,a ~ _ _ , , ~ , , _ _ ~ aa , . O-~J[ , v,; ~ ~ , o. ~ ~ , ,f , ~ ~ ~ ~ _ ~ ~ ~ ~ ~ ~ ,.i e~ ~ ,f,~~ ~ ~ v s s 0 a ~ - n o T o o~ o s n O ^ ~ O ~ o o e o 0 a 31 ~ o " n r M°~ a o ~ w o ~e c a ' p E o Q~ a o n~ ° a 0 0 _ o ~ a o~ m u o N, u» s o o~ v o ° n = c w v F~ m o 3-' _n .°w ~e n°~c 'vo3 c E o 0 0 ~ M D p d . p A o - ~ m ~ V n C) -i C -0 ? in o (n m D m 3 ~ c oo ~ m x ~ 0 m m 0o ~I D (7 ~ ~ - io s N ° XJ •m ~ A ' mo T 2 0 F ~ tt~ MC D L . ~ ~ y N ~ ~ 4~, C -V Z~^'n D O Q1 ~ .Sl oz v/ o sw °o lN . y Jm ZZ N m O m „ m T n ~ ~ n c g N 3 n tn f r c ~ x r 0 z 1 C y m i z ~ ~ y m ~ x y z F N 3 V g fTl r N Z ~I m < p ~ Z lQ +1 ~1 l ~y ]1 m fl r o ~ v o m c " ~n < > z n ~ m M O p m ~ Z m ~ p < c~ m t z m -i 7J N m C x ~ Sp ~ m t m y 0 ➢ ~ F 9~ ~ p c ~ m f o ~J p ~ ,y n n ~l m m rri 0 F ~ m N N ~ m r 3 ~ a r o ° m ~ n o n f D c~ ~n Z ~n p m ~ f N f 1 T 2 f 2 ~ 2 -1 - I m ~ z = = g N D o f £ ~ m ~ A ~ 1 x D x y n' m F ~ m c z m m ~ u°-~ ~ s r m r~ m N C N { ; Z co O Z r - G~ ~ ,a m N x ~ ' Z 0 i w \ O A ~ 2 0 m n m y m m o n w ~ ~ g < O n a' ~ m 0 D ~ 0 n ~ ~ D w ~ m ~ 0 ; D 0 ~ n O f~n D 2 ' 2 A e ~ Z ? Z O y Z 1 ~ ~t D , A ~ m m m m ~ c c m c u~ 3 1 ; ~ m R 0 0 N ? N f D D O y 2 w ~ n' z c~ n oN o ~ 'O 3 :E r ~m C) <m F°D -4 zn r^ m Z ~n0 Zao ~ z v Z m M = T 0 o m mgQ r Z -1 X 0 Z ~ , D c n m T z C Co O O W D 2 m m L) °nz_. cn,°c O \ ~ ~ r O N T D m ~ y O 2 ~ ~ C m m m z o c~ ~ n tn m z D n " z r o N 2 0 ~ u, o r Z nD ~ oDD ~ N Ao- 0 m R M~> °z , FD =sm m zMM ~ s c ~ r yo-1 r~ ~ Z O m z y y v ~ m 0 ~ o ~ z < 0 z 51 E PROPERTY LINE ~ g D ~ D o 0 m C ~j Z ~ ~ SIDE PROPERTY LINE v n i O + ~ x A n mf 0 m A D x n vy ~s 0o mf ~m m N Z£ z_ cm T mm O n m Z W { O m L z p~ D m N y ~ m a m 7J N W N - W ~V - A W N- (A ; -i N 1 ~ m C m m m m~ m m D p D s ~ x D n - i r - c N T N m M O ~ v O N e O Z o ' ' v ~ a v F p n F i O~ O v ~ m ~ s m N C ? C ~ ~ m ( ( ~ " m o v m o O y O ~ ° ❑ m 2 > Z Z ❑ I O i \ y O y ❑ ~ ❑ ° ❑ ~ m m ~ 11 r : ElI ° O 0 v y p f a F = -DI 2 . ❑I ' ❑I ~ D m y ~ m ~ n y O 1 ~ m ~ O a ~ n a ~ o s . : ° MTTI n ' I s 3 o v ~ O n ' o s ~ ~ e u O 2 e O T o` y Q ~ Y ° n N 0 a , ~ o • s ~ ~ a 8 • ~ R o ~ ~ x N ~ A I ~ 1 ' p ~ y 1 m O o a o C3 = OD ~ z X < r rnm ~ m m Z ; N L l z A~ O m ~ ~ O ~ m b m ~ m c~m ~ 3 p c -i r= m Z O ~~-4 o cz, ° cZi o = Z Cl n m m~~ o ~cm)c - p 31-IZ ~ : I 1 il . , i mz< 00 ; 0<<" ) OL-< 1 C)or I Z ~ l ~ ~ m Z ~ -0 m ~ ~ ~ Z O 3 ~ ~ ~ ~ ~ ~ s ~ _ X v O >1 A Y OR4 X ~ 'O o X ~ x g ,o3 y€s •O+ 3~0 D Q v l~Nly ~r0 n l 7 ' ~O ~ . . 4 , • 'R 6C 'a x-o~eRl ' ~lllri~~~ ~ X~ Jp a ~ . , " z v; .Q : . m O N~ ~ X,o1 •8 o22`S i ' r. > D o~ o~ - _ • II ~ 4 . cs 2 G " 0 ! ~ • pR oO . Z m 7 .`S .9 70 G ~ R~ ' • F y X E 101 f t ~ s , : V ' 23 4 .7o X e ~O X~ O ,s x 1'O ~J CXl r O8 X~ 020 ~ •s2 X ~o ~ 10,`9 i0'19 0, ot9 / ~?OF k ~ ~ a '°~n x'o2°o WEST 3 &-T-7 H--~A VY-LE N U E , y ~ . _ . . . . . . . ~ h+tC l`.:.. . . , " . { k ~ 4 ~ 4. . ~ ' . y . ' . _ . . . I DEPARTMENT OF COMMUNITY DEVELOPMENT 1 ~72 7500 WEST 29th AVENUE BUILDING INSPECTION DIVISION PERMIT NO. g /~7 ~2 237-6944 EXT. 255 P.O. BOX 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED BELOW. APPLICATION FOR MISCELLANEOUS PERMIT 10901 West 38th Ave., Wheat Ridge, C Wheat Ridge Fire District JOB ADDRESS OWNER CONTRACTOR Hughes-Groesch Construction, Corp. ADDRESS 3880 Upham Street, Wheat Ridge, CO ADDRESS 5615 Lamar Street PHONE 424-7323 -I ZIP CODE 80011 CITY Arvada ZIP CODE 80002-2623 CONTRACT PRICE ~$J a-00 00 HONE LICENSE NO., 6 1. TYPE Ground ❑ Woll❑ Proiecting❑ Other S or D Face 2. MATERIAL Total Square Feet SIGNS 3 ILLUMINATION Yes❑ No❑ Type Elect Permit No. . 4 SET BACK FROM PROPERTY LINE N_ S_ E_ W Zone_ Approved, Zone Inspector (Specify which is front) ❑ ❑ ❑ ❑ Disapproved 1. TYPE Solid❑ More Than 80% Open[:] Less Than 80% Open 2. MATERIAL Height FENCES 3. SET BACK FROM PROPERTY LINE N_ S_ E_ W Zone_ Approvsd,Zons Inspector (Specify which is front) ❑ ❑ ❑ ❑ Disapproved I~ Drainage and Landscape Improvements OTHER 3. DRAW SKETCH OR SHOW BELOW, THE FENCE,SIGN,OR OTHER STRUCTURE, GIVING DISTANCES FROM PROPERTY LINES. (SETBACKS OR PROJECTIONS INCLUDED) W J r a: SPECIFY NORTH rn STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TUADJOINING HOUSES, STREETS, AND PROPERTY LINES; ON IRREGULAR LOTS, SHOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 60 DAYS FROM DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN THAT TIME. ELECTRICAL PERMIT STATE LICENSE NO. ALUMINUM WIRE UNDER SIZE 8 ILLEGAL PLUMBING PERMIT STATE LICENSE NO. FLOOR BSM IST 2ND 3RD 4TH MECHANICAL PERMIT N0. FUEL.-Circle One Gas OIIPropane Cod Elec SOIOr NO. WATER CLOSET FORCED AIR - BTU TEMPORARY METER WASH BOWL HOT WATER - BTU NEW SERVICE - AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTING SINK OTHER HEATING GARBAGE DISP. REFRIGERATION SYSTEM POWER SUB-CIRCUITS UTILITY(RANGE, DISPOSER, ETC.) FIXTURES WATER HEATER AUTO.WASHER DISH WASHER Refri eronI Group Pounds Charge AUTOMATIC SPRINKLER SYSTEM WIRING MOTORS a CONTROLS FLOOR DRAIN ELEVATOR SIGNS URINAL TRANSFORMERS 8 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES I hereby acknowledge that this applica- tion is correct and understand that I cannot start this project until this apPli- cation is approved. I shall comply with the lows of the State of Colorado and to the Zoning Regulations and Building Code of the City of Wheat Ridge. Any violation of the above terms will cause X immediate revocation of this permit. 116 + 40PIIeanln 9lenature PERMIT FEE Z NOT VALID UNLESS RECE USE TAX Z 0.0 M7' TOTAL FEE / . /'~A BUILDINVIASPECTOR,City of Wheat Ridge Date Issued ~ 4/~ CALL 237-6944 EXT. 255 24 HOURS IN ADVANCE FOR INSPECTIONS DEPARTMENT OF COMMUNITY DEVELOPMENT 7600 WEST 29th AVENUE BUILDING INSPECTION DIVISION PERMIT NO. M92#18190 237-6944 EXT. 255 P.O. BOX 638 CITY OF WHEAT RIDGE, COLO. PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED BELOW. _ ARPLICATION FOR MISCELLANEOU$ PERWT/ A C JOB ADDRESS CONTRACTOR ~~i ADDRESS 6 OWNER r" ADDRESS/~~n~ 3 ZIP CODE PHONE TS%'3 , CITY l1 ~~Q6c ZIP CODE ~ ~ CONTRACT PRICE $ PHONE 2/YZ 7- 3 LICENSE NO. TYPE Ground❑ Wall[:] Proiecting❑ Other Sor D Face 1 . SIGNS 2. MATERIAL Total Square Feet ILLUMINATION Yes❑ No❑ Type Elect. Permit No. 3 . 4 SET BACK FROM PROPERTY LINE N_ S_ E_ W Zone_ Approved, Zone Inspector (Specify which is front) ❑ ❑ ❑ ❑ Disapproved 1. TYPE Solid[:] More Than 80% Open❑ Less Than 80% Open 2. MATERIAL Height FENCES 3. SET BACK FROM PROPERTY LINE N_ S_ E_ W Zone_ Approved,Zone Inspector (Specify which is front) ❑ ❑ ❑ ❑ Disapproved ~E 07~ l S, I . . OTHER 3. DRAW SKETCH OR SHOW BELOW,THE FENCE,SIGN,OR OTHER STRUCTURE, GIVING DISTANCES FROM PROPERTY LINES. (SETBACKS OR PROJECTIONS INCLUDED) -i- SPECIFY NORTH STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TO ADJOINING HOUSES, STREETS, AND PROPERTY LINES; ON IRREGULAR LOTS, SHOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT VALIDATION BY THE INSPECTION DIVISION. BUILDING D THIS APPLICATION WILL BECOME evo PERMIT an new FROM PERFORM DAE OF ISSUANCE OF WORK Y IS OT STARTED WITHIN THAT TIME. ELECTRICAL PERMIT PLUMBING PERMIT MECHANICAL PERMIT STATE LICENSE N0. STATE LICENSE NO. ALUMINUM WIRE UNDER SIZE 8 ILLEGAL FLOOR BSM IST 2ND 3RD 4TH N0. FtffL~Circle0ne Gap 011 Propane Cod Elea Solar NO. WATER CLOSET FORCED AIR - BTU TEMPORARY METER WASHBOWL HOT WATER - BTU NEW SERVICE - AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTING SINK OTHER HEATING GARBAGE DISP. REFRIGERATION SYSTEM POWER SUB-CIRCUITS WATER HEATER Refri sront Group ETC.) DISPOSER UTILITY (RANGE AUTO. WASHER Pounds Charge , , DISH WASHER AUTOMATIC SPRINKLER SYSTEM FIXTURES WIRING MOTORS B CONTROLS FLOOR DRAIN ELEVATOR SIGNS URINAL TRANSFORMERS 8 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES 1 hereby acknowledge that this opplico- tion is correct and understand that I cannot $tort this project until this appli- aation is approved. I shall comply with the lows of the State of Colorado and to the Zoning Regulations and Building Code of the City of Wheat Ridge. Any violation of the above terms will cause immediate revocation of this permit. PERMIT FEE USE TAX 3 4 NOT -7 a/ I 9 TOTAL FEE $ kl0- 7 D D CHIEF BUILDING INSPECTOR,City o Wheat Ridge ;ki] issued '_22 ?j~>' 22' CALL 237-6944 EXT. 255. 24 HOURS IN ADVANCE FOR INSPECTIONS Q o q0 ~ p ~ °D 3NO1S 43HSf121o~ b£ot X '0 4 ~~O •'b ~.yo` W 6~ X ~h •~n~ ~"'X ~ ~ ~~o 0tir~t; + • . • . . . ' •0.1,° ~o• 0 ~ . p ~ +C Vti q \ • W ~ ~ X ` X O~' D ` `O 9 . 9L'ZOl ~ X o ~ ~4 i ' 0o X ~ ~ ` O 9 ~ . 9 \ y o DO j 0 X ~O ~ m oo X sr• 6 ~ ~ oo` ~i ss• , s. p x ~ O 0 O~ O~ - y X gs. O 0 I w ~ o o I o, 0 , 00 00` ~ oo` . ti'1 . - e x a~ 9 n~ ~ 44" ~ X 6F' tib ~7 ~p l''✓ X 66 r-77:n= o` ~O 9 DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 5427 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7111/97 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : Property Address : 10901 38TH AV Phone : 424-7323 Contractor License No. : 18991 Company : J. R. Phillips Construction Co., Inc. Phone : 2332201 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certiy that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rutes or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.G) and all other applicable Wheat Ridge ordinances, forwork underthis permd. (OWNER)(CONTRACTOR) SIGNED DATE Description : REFACE FIRE STATION Construction Value : $22,000.00 Permit Fee : $0.00 Use Tax : $0.00 Total: $0.00 Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiration Date : Approval: Expiration Date : Approval : Expiration Date : Approval: (7) This permit was issued in accordance with the provisions set forfh in yopur application antl is sub7'ect to the laws of the State of Colorado and to the Zoning Regula[ions and Buiiding Code of Wheat Ridge, Coloratlo or any other applicable ordinances of ihe City. (2) This permit shall expire if (A) the work authorizetl is not commenced within sixry (60) days from issue date or (e) the building authorizetl is suspended or abandoned for a penotl of 720 days (3) If this permit expires, a new permit may 6e acquired for a fee of one-haif the amount norcnally required, provided no changes have 6een or will be made in the original plans and speafications and any suspension or abandonment has no[ exceeded one (1) yeac If changes are made or if suspension or abandonment exceeds one (1) year, full fees shali be paid for a new permit. (4) No work of any manner shall be done tha[ will change the naNral Flow of water causing a drainage problem. (5) Cont2ctor shall nollfy the Building Inspector lwenty-four (24) hours in advance for all inspections and sha0 receive written approval on inspeclion card before proceediing with successive phases of the job. (6) The iseL~nce of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of try~ bifilding cpdes or any otherprdinance, law, rule or regulation. ~f Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEP BUILDING INSPECTOR AND MAYOR CALL• 234-5933 24 HOURS PRIOR TO INSPECTION