11525 W. 38th Avenue
L� PERMIT NO: JOB ADDRESS: SOB DESCRIPTION: * * * (nATT 7T n-, City of Wheat Ridge Residential Roofing PERMIT - 201702540 201702540 11525 W 38th AVE ISSUED: 06/26/2017 Residential Re -roof to install Owens Corning 06/26/2018 g asphalt shingles with 27 sq OWNER (303)635-6114 VICTORIA E LANGHOLZ TRUST SUB (303)289-7952 Precision Siding & Constructio *** PAR( PT. TAI- - 150121 Precision Siding & Constructin ZONE CODE: v UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: USE: *** FEF 9TTMMIn- — Total Valuation Use Tax Permit Fee ** TOTAL ** *** CONDITTnvQ **{ UA / Unassigned 0 / ESTIMATED PROJECT VALUATION: FEES 12,000.00 0.00 252.00 236.00 488.00 Effective December 1, 2014, asphalt shingle installations require inspection, conducted when 25-75 approval. Installation he roof 5perct of the roof covering an approved for to prior to installation of sheathing (new or overlay)g is installed, prior to final or board installation ANY roof coverings irequires t approved inspection sheathing with ANY g and is require on the entire roof when s be fastened to the roof deckgwiithxaemiinimum ofeding n6h exists. paced required. Eave and rake metal is required. Asphalt shingles are required to nails per shingle. Ice and water shield is and secured ve place is re q A ladder extending3 feet is required to comply required to be provided for all roofinspections the roof eave instructions, p Y with applicable codes and/or manufacturer&€WS installation ventilation whichever is more stringent. In order to pass a final inspection elastomeric or similar of manufacturer's type roof coverings, a letter of inspection and a technical representative stating that "the application (project address) has been aPProval from the (roof material Polled in accordance with the instalatonin�tructionf the ofor t brand name) roof cov inspection. ering" is required to be on site at the time of final QOccupance INSPECTION RECORDfid- -79 VECTION ONLINE FORM: http://www.ci.wheatridge.co.0 x . s/forms INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be perfonned unless this card is posted on the project site. inspection request line before 11:59 p.m. to receive an inspection the following business day.** Call the 9 ect Inspector Datctor Must Sign ALL Spaces pertinent to this pro 1 Inspector Comments )undation Inspections e Initials er �ncrete Encased Ground (CEG) �undation I P.E. Letter royal Of The Abov�In ections Do Not Pour Concrete Prior To App Inspector Comments Inderground/Slab Inspections Date Initials :lectrical >ewer Service plumbing Do Not Cover Uncle Rough Inspections Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw I Nail Final Inspections round or Belowll n pab ec oWork Prior To Date Initials Landscaping & Parking / Planning Dept. ROW & Drainage I Public Works Dept. Floodplain Inspection (if applicable) Fire In-pection I Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical I Roof i Final Window/Doors I Of ehT Above Ins Comments ons Inspector Comments Date Initials Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Final Building public Works, Fire and Building before a Certificate roved by Planning, NOTE: All items must be completed val of the Fal Building inspection does not constitute authorization of occupancy. of Occupancy is issued. App p es n from the Fire District and electrical low voltage *For low voltage permits — Please be sure that rough inspections are comp by the Building Division. anC Is Issued Occupancy Is Not Permitted Until This Certificate ertif From at The0We Cher y Protect af) I ] D3� 9� INSPECTION RECORD Occupancy/Type INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection So �AK INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Mid -Roof Foundation / P.E. Letter Lath / Wall Tie Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical j' Final Plumbing y Final Mechanical Roof Final Window/Doors Final Building NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Solar PERMIT - 201703780 PERMIT NO: 201703780 ISSUED: 07/20/2017 JOB ADDRESS: 11525 W 38th AVE EXPIRES: 07/20/2018 JOB DESCRIPTION: 4.5 kw Residential roof -top solar pv grid -tied flush mounted *** CONTACTS *** OWNER (303)635-6114 VICTORIA E LANGHOLZ TRUST SUB (303)904-2268 Ray Williams 120156 Suntalk Solar *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,125.00 FEES Total Valuation 0.00 Res Solor Review 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized byte legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I am legally authorized to include ali entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Isuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Offcial and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code ordinance or re neo his jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Residential Roofing PERMIT - 201702540 PERMIT NO: 201702540 ISSUED: 06/26/2017 JOB ADDRESS: 11525 W 38th AVE EXPIRES: 06/26/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning asphalt shingles with 27 sq. *** CONTACTS *** OWNER (303)635-6114 VICTORIA E LANGHOLZ TRUST SUB (303)289-7952 Precision Siding & Constructio 150121 Precision Siding & Constructio *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 12,000.00 FEES Total Valuation 0.00 Use Tax 252.00 Permit Fee 236.00 ** TOTAL ** 488.00 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding Aid -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€'"s installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201702540 PERMIT NO: 201702540 ISSUED: 06/26/2017 JOB ADDRESS: 11525 W 38th AVE EXPIRES: 06/26/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning asphalt shingles with 27 sq. 11 by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am leggggally authorized to include all entities named within thi document as parties to the work to be performed and that all work tolge per 9P d is disclosed in this document and/ori accom anying approved plans and specifications. /7 Signature of OWNERZ- or Qa7KTRACTOR (Circle one) Date 1, This permit was issue ,"ased on the information provided in the permit application and accompanying plans and specifications and is subject to the comp1i�ar =_with hose documents, and all applicable statutes, ordinances, regulations, policies and procedures. ?, This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original pen -nit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior andspecific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Dan Schultz ad 1`7 0 *), 1� 1q D From: no-reply@ci.wheatridge.co.us Sent: Wednesday, June 14, 2017 11:31 AM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Danny Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being processed within 3-5 business days, subject to change based on volume. L l L. FXP For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number 11525 W. 38th Ave Victoria Langholz 303-635-6114 Property Owner Email Field not completed. 'es 4 w- CD cfsn jn- 10 b Address Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Precision Siding and Construction 150121 303-289-7952 Contractor Email Address tyler(opsandc.com (permit pick-up instructions will be sent to this email) Retype Contractor Email tyler(a)psandc.com Address DESCRIPTION OF WORK Are you re -decking the No roof? Description of Roofing Asphalt- Owens Corning Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 27 material selected above? Does any portion of the No property include a flat roof? If yes, how many squares Field not completed. on the flat roof? 2 TOTAL SQUARES of all 27 roofing material for this project Provide additional detail House and Detached Garage and Shed 6/12 here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 12000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Tyler Briola Email not displaying correctly? View it in your browser. 3 PRECISION SIDING & CONSTRUCTION COMPANY INSURANCE RESTORATION WINDOWS • SIDING • GUTTERS • ROOFING National Headquarters 0' AN Z Insurance Provider: Au e(ii 6./ 6 — t)Z Phone#: 7000 N. BROADWAY, #3-300 Phone #: 3,151 B DENVER, COLORADO 80221 Q 9 11-7 Phone #: (303) 289-7952 BBB/Member 1-800-748-3114 for over w r r: Customer: Address: 0' AN Z Insurance Provider: Au e(ii 6./ 6 — t)Z Phone#: Policy #: g Z �77 25 G Claim #: Phone #: 3,151 _ Project Manager: Date: Q 9 11-7 Phone #: Approximate Dollars ($) pe8oc k: {o6_ + '1��c7�„p sLG Shingle Manufacturer �iJS (r� :/y C!1 _P lli1�/U✓t ColorT_f?�,� Tear off— layers of composition shingles Install Decking (7/16" OSB) A4, V e oCg Install new felt / t F) Install new shingles Install pre -painted eave metal to code -Color KRidge(s) to be color -coordinated Install new pipe jacks Replace vents as needed Re -flash chimneys and all abutment as needed and if possible (stucco or siding may be a deterrent) Install ice and water shield to code. Install ( nails per shingle j Clean out gutters 5 Year workmanship warranty (+Precision Siding & Construction will provide general liability insurance coverage of at least $2,000,000 oke a magnetic sweep of driveway and yard for removal of any nails emove all debris resulting from the above work [ ) Special Instructions [ j Tear off one layer of wood shingles SP77ZI- TIONS: 5 j J i LS J- F- s i i-\ d- I-T4W(J oma- L -,/M PS Approximate Date of Roof Completion: Start: ktk If initiated by buyer, then the contract price is contingent upon insurance approval; and buyer is only responsible for his/her deductible. When the insurance carrier agrees to pay the claim for damage to the property, then the buyer agrees to allow Precision Siding & Construction Company to perform all repairs prescribed by the insurance company's adjuster report. By reference, said adjuster's report and estimate becomes and here is a part of this contract. TERMS AND CONDITIONS I/We the owners of the premises described below, hereinafter referred to or understood as "Owner/Buyer," offer to contract with Precision Siding & Construction Co., Inc. hereinafter referred to as "PSC" to furnish and deliver and arrange for installation of all materials necessary to improve the premises according to the specifications attached hereto. L This agreement is subject to final approval by PSC and is the entire agreement of the parties and no other terms will be recognized. 2. Stating that the roofing contractor shall hold in trust any payment from the property owner until the roofing contractor has delivered materials or has performed a majority of the work 3. Any supplemental payment from the buyer's insurance company is due to PSC including Contractor's Overhead and Profit. 4. Labor Warranty does not cover damage caused by natural disasters: lightning, gale force wind, hurricane, tornado, hailstorm, and impact of foreign objects or other damages due to settlement, distortion, improper ventilation of the building envelope, or failure of the roof deck, walls, or foundation of a building. PSC shall be held harmless and free from all liability and legal action relating to any presence of Mold at the subject property regardless of the legal theory upon which any such claim rests. 5. PSC is not responsible to provide any materials or to perform any work other than what is described above. 6. 1.5% monthly will be added in daily increments to the balance of any and all unpaid portion of contract, commencing upon completion date reception of remaining insurance proceeds. 7. PSC will perform all work according to local building codes and specifications. 8. If this contract is canceled by the buyer later than three (3) days from signing, the buyer shall pay to PSC, an amount equivalent to thirty percent (30%) of Approved Replacement Cost Value, as liquidation damages, and PSC agrees to accept such as reasonable and just compensation for said cancellation and Consequential loss of profits. 9. Contract may be rescinded within 72 hours after the property owner receives written notice that the Insurance claim has been denied. 10. Buyer shall provide all electricity necessary to complete the above scope of work I1. PSC shall not be liable for any structural movement, settling, cracks in drywall, driveways or dents in gutters created during normal construction procedures. 12. Before any warranty, written or otherwise, is to be considered valid, the Contract must be paid in full. In the event of a problem, due to Workmanship, PSC must be notified in writing within 10 business days of discovery of said problem. PSC must be allowed to inspect and correct the problem before anyone else, and will not be held responsible for any problems arising from long-term exposure to water. 13. Each trade represented will be payable in full at completion of said trade. 14. If customer fails to pay for services performed by PSC then the Customer is responsible to pay all legal Costs and Fees acquired by PSC in pursuing payment. 15. Final payment shall not be held up while waiting for city or county inspection. 16. PSC reserves the right to reject work at any time. If PSC rejects a portion of the contract the home owner will be reimbursed for work not completed. 17. PSC reserves the right to order excess materials, All excess materials are property of PSC. 18. The Contractor cannot pay, waive or rebate an insurance deductible. Ali checks made able Precision S ing & C struction Company. r Owner: ' Consultant: i Ll r Date: Approved By: e t I i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: AAX 13 Job Address: IA/ 3r" i9 V Permit Number: z G 0 2 S a' No one available for inspection: Time `:.' -% AM/PM Re -Inspection re -quired- Yes No -. - timen corrections have been made, call for re -inspection at 303-234-5933_. Date: Inspector:--(-,-/ DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F mxk� Job Address: d 5 iJ 38tq Cj,> Permit Number: 00J76 c25gD ❑ No one available for inspection: Time :KM/PM Re -Inspection required: Yes 6No'_--' When corrections have been made, call for re -inspection at 303 -234 - Date: 2/07 Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE jj Inspection Type: ` ' EX) Job Address: / / 5-2-.5— �^! Permit Number: 20/1- , U Z,57 410 ❑ No one available for inspection: Time °._r AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303 -234 - Date Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: _ Job Address:115-7 S ,A S e ; t, // Permit Number: 2-0/?"0251l/0 ❑ No one available for inspection: Time/ 0 AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Solar PERMIT - 201703780 PERMIT NO: 201703780 ISSUED: 07/20/2017 JOB ADDRESS: 11525 W 38th AVE EXPIRES: 07/20/2018 JOB DESCRIPTION: 4.5 kw Residential roof -top solar pv grid -tied flush mounted *** CONTACTS *** OWNER (303)635-6114 VICTORIA E LANGHOLZ TRUST SUB (303)904-2268 Ray Williams 120156 Suntalk Solar *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,125.00 FEES Total Valuation 0.00 Res Solor Review 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I by my signature do hereby attest that the work to be performed shall comply with all accompanyingg approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am Elie legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed and that all work to;be perfumed is disclosed in this document and/or its' accompanying approved plans and specifications. 7 Signature of OWNER or CONTRACTOR (Qircle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtamed. Issuance of a new permit shall be subject to the standard requirements, fees andprocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall notmroceed or concea wor 'Wit out written approval of such work from the Building and Inspection Services Division. 6. The issuance or grant' _ ' hall ed to be a permit for, or an approval of, any violation of any provision of any applicable code or an or regulation of this risdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City Of �W heat Edge COMMUNrry DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Request Line: 303-234-5933 Building Permit Application (Complete all highlighted areas) Property Address 11525 W 38th Avenue, Wheat Ridge, CO 80033 Property Owner (please print): Vicki Langholz Mailing Address: (if different than property address) Address: Same as Above City, State, Zip: Contractor: SunTalk Solar Phone: SCb.Co PAID C:�-635=6i-r4 µ Contractors City License #: 120 156 Phone: 303-904-2268 Sub Contractors: Electrical: Plumbing: Mechanical: City License # City License # City License # Description of work: (Fully describe work to be performed - Attach additional sheet if necessary) ��` / �no� ��� �U Contract Value of all work: Gr"A -'j i e r� i i u 5 �1 � $ 10,125 Review Fee (due at timjel of submittal): Squares BTU's Gallons Amps Sq Ft. $���dL! / r (-,/) , OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEiNIENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, casements or restrictions of record, that all measurements shown and allegations made are accurate: that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application, that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. rte` CIRCLE OAE (0111'NER) (41'THORIZED REPRESEA'TATII'E) of (OWNER) (CONTRACTOR) PRINT NAME: W, -z to SIGNATURE: DEPARTMENT USE ONLY ZONING COMMENTS: Zoning: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: DATE: 7 / it) OCCUPANCY: FIRE DEPARTMENT:. 0 approved w/ comments 13 disapproved C3 no review required I Bldg Valuation: $ ,0 Lopez Smolens Associates Consulting Structural Engineers June 16, 2017 To: City of Wheat Ridge Building Department Re: Roof -mounted PV Installation on Existing Residence Engineering Project #: S17416 11525 W 38"'Ave Wheat Ridge, CO Plans Examiner, This letter is to state that I made a general review of the existing roof structure in reference to supporting the point loads from the proposed solar panel racks and supports. As required by the 2012 IRC, and the City of Wheat Ridge amendments to the aforementioned codes, the roof will be subject to design loads of 30 psf snow load and a wind load of Vasd =185 mph 3 -sec. gust, exposure C. The panels will add a dead load of 4 psf. The review confirms that the existing structure is adequate to support these loads, with the following assumptions and modifications: The east facing roof appears to have 2x6 rafters at 18" o.c. spanning 8' with a 6/12 pitch. This roof structure is adequate to support the design loads without any additional reinforcement. The south facing appears to have 2x6 rafters at 24" o.c. spanning 12' with a 6/12 pitch. These rafters are not adequate to support the design loads. A 2x10 collar tie should be added at mid height of each rafter pair below the array. Attach the collar tie to the rafters with 5- SD525300 (1/4" diameter x 3" SDS) at each end (min. edge distance, end distance, and spacing per manufacturer). Pre drill holes as needed to prevent splitting of the wood. The PV panels will be located at least 12" away from all edges of the roof plane, and will not be more than 12" above the roof. PV panel mounts (Rock -It Mounts from EcoFasten Solar) should be spaced at 48" maximum. Vertically -adjacent mounts should not bear on the same rafter but should be staggered over every other rafter (wherever possible) so that each rafter under the array supports some load. A layout of the mounts is included in SunTalk's design package. The mounts should be attached to the rafters with 5/16" -diameter stainless steel lag screws with a minimum penetration of 2" into the center of each of the rafters. Each rafter that supports a mount is.assumed to fasten to the exterior bearing plates with a Simpson H2.5 hurricane tie, or equivalent. The Rock -it System is a rail free solar roof mount system. All panel connections to mounts and couplings are to be per manufacturer's recommendations. I understand that the Rock -It System (including both the mounts and the panel to panel couplings) has been reviewed independently and certified by a registered professional engineer in the state of Colorado. It should be noted that only a portion of the roof structure was observed. We do not assume responsibility for any construction flaws or defects that may currently exist or are caused by the proposed installationLzl., Sincerely, city oe Wheat Ridge Ian M. Smith, P.E. p�vison 80009 2400 Central Ave., A-1 North, Bou er, CO 80301 (303) 447-2813 fax (303) 447-2814 OOH., .... L _cos" �. 2 j0, � F � �TA 11525 W. 38TH AVE. HEIGHTS � L�� • '� f •i ! .,i its ."�W 41st Aye Z t/1 3 -; 3 W 38th Pf ?11525 West 38th Avenue ,7 38th tive Z o Cn P'v e [ r ( { 3 ^► _ u' "fir CL -t rt C' `�'� 35th Aver W 35th Ave W :35th Ave V111o ers PROJECT SUMMARY System Size: 4.50 kW PV Watts: 6,430 AC kWh/Year Module: (15) Silfab SLA300M Inverter: (1) Solar Edge SE3000H—US —1 Strings of 15 Modules Racking: Rock—It w/ Flat Flashing Snow Load: 30 psf Wind Load: 105 mph, Class C Interconnection: Load Side Interconnection (20A Breaker) Roof: 25yr Comp. Shingle (N 10yrs, Good) Single Layer of Shingles Array 1 (4,921kWh) — Tilt: 26° Azimuth: 90° A �'� atycof [�� MWNT' Array 2 (1,509kWh) — ''COMMUNITYDEvWw Tilt: 26° Azimuth: 180° APPROVED Installer: SunTalk Utility: Xcel AHJ: City of Wheat Ridge Puns E aminer Date CONTENTS VslidRv of cermit The issuance o/a permit or approval of pJo 1.0 Cover Page and computations shall not be a permit fw, or an approval of, any of the provisions of the building code or of any City ordino 1.1 Site Plan presuming to give outhoro to violate of cancel the ptimisiam 1.2 Module Layout codes or other ordinances of the City sholl not be valid 1.3 Details 2.0 Single Line Diagram 3.0 Calculations 3.1 Placards 3.2 Placard — Rapid Shutdown 4.0 NREL PV Watts 5.0 : Commissioning Component Specification Sheets N N C) V' 0 0 C� C� M M O o 0_ L� E N o C u 2 i � d O O U) 0 � d W 3 U1 3 3 E Z 0 0 LLJ D° Q0 _'j Qo00L� Ln r _j J �— tri Q 10 tiYN W > � � n JOB NO. 8615 DATE 5/21/17 1.0 City of Wheat Ridge 260 AT 90 & 180 AZIMUTH 25YR COMP SHINGLE (SINGLE LAYER) ROOF (~10YRS, GOOD) *SOUTH FACING ROOF REQUIRES STRUCTURAL UPGRADES. PLEASE SEE ENGINEERING LETTER FOR SPECIFICATIONS. E— — 11525 W. 38TH AVE. 2 /6 N I m 5oufh fGcinq Poof -)`-- 11525 W. 38TH AVE,, SOLAR LAYOUT SCALE: 3/32' = 1'-0' EQUIPMENT SCHEDULE Ol MODULES ZINVERTER OPV DC DISCONNECT ®PV PROD METER 50MAIN PANEL ©UTILITY METER LABEL UTILITY METER AND PV PROD METER PH❑T❑VOLTAIC SYSTEM CONNECTED 1,0 �D N N N N C) <D 0 0 ai c*i 0 0 ro cn E 0 o i _d o 0 U) V) ai d v� w 3 0 3 3 0 .0 Lu 00 Q0 J=C)� m0w� c� m2�C.7c� I Q� Y N wI ;`n=0 JOB NO. 8615 DATE 5/21/17 SHEET NO. City of Wheat Ridge Building Divison, co olk ID�D N N N N C) C) O O C� 0� M M O O M M E O c U o i � d 0 0 V) M T Y � d C H C: LLJ 3 N � 0 3 V1 3 3 w ~ N I!7 m = za x a a a a , W LL o O U W 2 d Q z 0 M M O .0 W 00 QO J S O ,d- o O FA -L 0 cfl O M I �Ja� _Lo< Y N ouLC) > 7 3: n JOB NO. 8615 DATE . 5/21/1 7 C'til SHEET No. lNh 9�uo,�n at R�ryge 1.2 RIDGELINE CLAMP MODULE R❑CK—IT W/ FLASHING LAG BOLT TRUSS DECKING 1155 W. 38TH AVE, ATTACHMENT 1'3 SCALE 1'-0' AC DISCONNECTS PHOTOVOLTAIC SYSTEM CONNECTED UTILITY METER INTERCONNECTION ❑CPD (U(U (U (U 00 mm 00 mm O o� d o O n W T Y d c ~ w � 3 a � 0 3 � 3 3 r7 0 .o LLJ 00 Qo J S V -0 1-- L � NO I 00 r7 _ Lo Y N oVLn=0 >73r7 JOB NO. 8615 DATE 5/21/17 �ypi:f:4il:D2 1.3 City Of eat Ridge AUX GROUND Rem [LITY JE ARRAY SPECIFICATI❑NS EQUIPMENT SCHEDULE EQUIPMENT SCHEDULE CONT. GENERAL NOTES 4.50 kW 0(15) SILFAB SLA300M SOLAR MODULES. ©PROVIDE A 2 -POLE 240VAC 30A OUTDOOR NEMA 3R SERVICE RATED 1 ( ) MINIMUM PERMANENT SIGNAGEYELLOW PLACARD, BLACK (15) SILFAB 30OW MODULES DISCONNECT. 1 STRING OF 15 MODULES 02 SOLAR EDGE P300 OPTIMIZERS (EACH STRING PHOTOVOLTAIC DISCONNECT SHALL BE VISIBLE, "PHOTOVOLTAIC LETTERING): OF OPTIMIZERS LIMITED TO 350VDC NOMINAL ACESSIBLE, LOCKABLE, LABELED (A) ON COVER OF VISIBLE UTILITY DISCONNECT — OUTPUT). AC DISCONNECT" WITHIN 10 FEET OF "PHOTOVOLTAIC SYSTEM DISCONNECT" MODULES SPECIFICATI❑NS 03 OUTDOOR JUNCTION BOX. ELECTRICAL METER. (B) ON FRONT COVER OF MAIN SERVICE PANEL "WARNING: MANUFACTURER SILFAB 07 PROVIDE A 2—POLE 20 CB IN EXISTING 240V THIS PANEL ALSO FED BY SOLAR ELECTRIC SOURCE." MODEL: SLA300M ®SOLAR EDGE SE3000H-US GRID -TIE INVERTER, MAIN ELECTRICAL PANEL WITH 2O0A MAIN C ON BILLING METER AND PV PROD METER - V❑C; 40.53 V 0VAC OUTPUT, INTEGRATED , BREAKER AND 200A BUSS. "PHOTOVOLTAIC SYSTEM CONNECTED" VMP 32,9 V ARCyF ULT PROTECTIONTH DISCONNECT, AND ISC1 9.76 A INTERNAL RAPID SHUTDOWN. UL 1741 AND IEEE 1547 COMPLAINT. FEEDER SCHEDULE (2) SIGNAGE OTHER THAN THAT GIVEN IN (1) ABOVE MAY BE IMP1 9,26 A ®PROVIDE 1 10 AWG(+), 1 #10 AWG — PV # ( ) REQUIRED aV❑C, -0.30%/"C Q5 200A, 1 PH LEVER BY-PASS PV PRODUCTION WIRE (�65' LENGTH). METER. THE SELF-CONTAINED METERING WILL INVERTER SPECIFICATI❑NS BE IN COMPLIANCE WITH THE MOST RECENT OPROVIDE (3) PV MODULES, STRING COMBINERS, GFI, DC DISCONNECT, MANUFACTURER: SOLAR EDGE REVISION OF THE XCEL ENERGY STANDARD; A #6 AWG GROUND. INVERTER, AC DISCONNECT, AND UTILITY DISCONNECT ARE M❑DELl SE3000H-US SPECIFICALLY SECTION 4.13. THE PV UL -LISTED. INVERTER OUTPUT 3,OkW PRODUCTION METER WILL BE REQUIRED TO ®PROVIDE 1 #10 AWG(+), 1 #10 AWG(-) INVERTER VOLTAGE 240 V HAVE THE PV GENERATION WIRED TO THE UNE SIDE TERMINALS (TOP OF METER BLOCK). THE THWN-2, 1 #10 AWG IN 1/2" C. (-35' LENGTH). (4) ALL GROUND SYSTEMS ARE BONDED TOGETHER. INVERTER CURRENT: 12.5 A METER SOCKET FOR THE PV PRODUCTION CONT. CURRENT; 15.63 A METER SHALL BE MARKED WITH A STAMPED � � # PROVIDE 3 AWG THWN-2, 1 10 AWG (5) INTERCONNECTION WILL BE PER LOCAL UTILITY REQUIREMENTS BRASS, ALUMINUM, OR STAINLESS STEEL TAG, INDICATING THE ADDRESS INCLUDING THE UNIT, (G) IN A 3/4" EMT C (-5' LENGTH). (DOUBLE -POLE CB OR LINE SIDE TAP). TYPICALLY LABELED "PV PROD" IN ACCORDANCE WITH WITH THE REQUIREMENTS (6) SYSTEM CANNOT BE TESTED ON LINE UNTIL APPROVED BY FOR "METER IDENTIFICATION" IN SECTION 4.14.4 UTILITY. OF THE XCEL ENERGY STANDARD. PV PRODUCTION METER SHALL BE LOCATED WITHIN TEN (10) FEET OF THE EXISTING UTILITY METER. (7) THE PHOTOVOLTAIC SYSTEM WIL BE INSTALLED IN COMPLIANCE IF THERE IS ANY REASON THIS CANNOT BE WITH ARTICLE 690 OF THE 2014 NEC. ACCOMPLISHED, A SITE PLAN SHOWING THE PROPOSED EQUIPMENT LOCATIONS SHALL BE (8) ALL WIRES MUST BE COPPER AND SIZED FOR A MAXIMUM 2.0% SUBMITTED FOR REVIEW. THE LOCAL METER VOLTAGE DROP. SHOP MUST APPROVE THE SITE PLAN FOR THE APPLICATION APPROVAL; SITE MEETINGS CAN BE ARRANGED UPON REQUEST. M ro O O > 00 QO J = U �O�W� vim 00 3 oz I �Jj�OfLn _L0Q� Y N o V Ln to JOB NO. 8615 DATE 5/21 /17 SHEET No. City ofi 2.0 ARRAY SPECIFICATIONS 4.5,0 kW (15) SILFAB 30OW MODULES 1 STRINGS OF 15 MODULES MODULES SPECIFICATIONS MANUFACTURER:SILFAB MODEL: SLA300M V❑C:40.53 V VMP:32,9 V ISC:9.76 A IMP; 9,26 A aV❑C: —0.30%/°C MODULE TO SOLAR EDGE (MANUFACTURER WIRE) VOLTAGE: 46,61V x 1 = 46.61 V AMPS 9,76Ax1.25 = 12.2 A INVERTER SPECIFICATIONS MANUFACTURER: SOLAR EDGE MODEL: SE3000H—US INVERTER OUTPUT: 3,OkW INVERTER VOLTAGE: 240 V INVERTER CURRENT: 12.5 A CONT, CURRENT: 15.63 A SOLAR EDGE TO JUNCTI❑N BOX #10 AWG PV WIRE, #10(G) VOLTAGE: 380 V (POWER LIMITED) AMPS: 15,OAx1,25 = 18.75 A CONDUCTOR: 40AxO,8xO.77 = 24.64A 24,64 A > 18.75 A PER 690,8(B)(2)(1a) JUNCTI❑N BOX TO INVERTER #10 AWG THWN-2, #10(6) VOLTAGE: 380 V (POWER LIMITED) AMPS: 15.OAx1,25 = 18.75 A CONDUCTOR: 40AxO.8xO,77 = 24.64 A 24,64 A > 18.75 A PER 690,8(B)(2)(b) TEMPERATURE FOR (80033) PER ASHRAE: LOWEST: —25°C —13°F HIGHEST: 34°C 93°F TEMPERATURE CALCULATI❑NS 46.61 V = 40.53 V x (1+((-25°-25°C)x-0,307/°C)) 93°F+40°F = 133°F 0.77 CORRECTION FACTOR FOR 90°C 0.65 CORRECTION FACTOR FOR 75°C (TABLE 310,15B21o) INVERTER TO AC DISCONNECT #6 AWG THWN-2, #10(G) VOLTAGE: 240 V AMPS: 3,OkW/24OVxl,25 = 15.63 A BREAKER: 20A AC DISCONNECT TO MAIN PANEL #6 AWG THWN-2, #10(6) VOLTAGE: 240 V AMPS: 3,OkW/24OVxl,25 = 15.63 A BREAKER1 20A LOAD SIDE INTERCONNECTION MAIN BUS: 200 A ALLOWABLE: 200A A X 120% = 240A 200 A MAIN + 20 A PV = 220 A 240 A > 220 A SYSTEM MEETS NEC 690.64 & 705,12(D) IDID cu (U cU Rl C) C) 0 0 mcn 00 M m d!L E 0 o L d 0 > Y v H Lu 3 f� 0 3 cn 3 3 0 0 w 00 Qo J = U It U � I Ln_LQco � Y 04LLI ti;�In �o JOB NO. 8615 DATE 5/21 17 City of sHEET N . eat Ridge 3.O [lding Divisor 525 W. 38TH AVE. PLACARDS 0 ON JUNCTI❑N— WARNING: PHOT❑VOLTAIC POWER SOURCE MAXIMUM POWER—POINT CURRENT; 83 ADC MAXIMUM POWER—P❑INT VOLTAGE: 380 VDC MAXIMUM SYSTEM VOLTAGE: 480 VDC MAXIMUM CURRENT: 11,8 ADC ON INVERTER: WARNING: ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED, EQUIPPED WITH RAPID SHUTDOWN. Q ❑N AC DISCONNECTS: PHOTOVOLTAIC AC DISCONNECT NOMINAL AC VOLTAGE: 240 V RATED AC CURRENT: 12,5 A AC WARNING: ELECTRICAL SHOCK HAZARD DO TERMINALS ON BOTH LINE AND ENERGIZED ® ON PV PROD METER; PV PROD O 2181 NOT TOUCH TERMINALS. LOAD SIDE MAY BE ON MAIN SERVICE PANEL AND UTILITY METER; PHOTOVOLTAIC SYSTEM CONNECTED 0 .O w 00 QO J = U I'd - 0 �— Lj 10 rLr UJ) oZ _Ln< �YNw� tiU�=O > rn JOB NO. 8615 DATE 5/21 /17 ` pity of SHEET NO. heat Ridge 3.1 �idin9 DM50T 525 W. 38TH AVE. EQUIPMENT SCHEDULE 1QMODULES QQ INVERTER 33 PV DC DISCONNECT QPV PROD METER Q5 MAIN PANEL ©UTILITY METER N N N N 00 ri ri 00 m m E LZ E O � U O i d N 0 a" d c � Lu :3 0 3 U1 3 3 O .0 W 00 QO N = U �O�w .=� 000 c0 O I _ Lr) Y Ni oUin=0 5; 1- 3: M JOB NO. 8615 DATE 5/21/17 City of 3HElf NO. heat Ridge 3.2 uildinq Divison NREL RESULTS 4,921 kWh per Year stsem arrPw mar rarge ran 4snros.6mkvmPayearraafn�s ro„r Month Month Solar Radiation AC Energy Energy Value (kWh l mel day) (kWh) (S) January 3,82 323 36 February 4,34 333 37 rom+n. .ma.n a March 5.83 487 54 April 6.19 485 S6 u,M1 May 6,07 484 53 rxr r..,v.mn June 6.06 461 51 _ July 6.05 ass 51 wer mue.4.vr 1112August August 6 2 476 53 1-1 .I September 5.81 439 49 "'son"' yve a .n u+e... October 4.65 374 41 .v.w4, rw.n November 4.65 373 41 srlue.nwrax «r M and. December 2 6 227 25 Annual 5.15 3.921 S 545 Location and Station Identification Roof ... rod Location Requ.stod Location 11525 W. 38TH AVE, WHEAT RIDGE CO 11525 W. 38TH AVE. WHEAT RIDGE, CO Weamer Data U... Weather Dal. Somme RMY3) DENVERICENTENNIAL (GOLDEN - NREL), CO (7MY3) DENVERICENTENNIAL (GOLDEN-NREL), CO 3.3 mi 3.3 mi Latitude Latitude 39.74' N 39.74° N Lon9lbads longitude 105.18'11Y 105.18' W .mr. vmvun x rvmxazw+v. PV System Specifications (Residimhap PV System Specifications (Residential) _ X. OC System 51. DC $ystem Size 32 kW Module Type Module Typ. Standard Amy Ty" o. Ansy Type Fined (open rack) Army Tih .x4 4a,�v Am,, Tilt 26' Amy Azimuth Amy Aci-th iso. Sy.tem Loss.. System to ... c 14% Inverter EMeieney Invader Mclim y 96% DC to AC sure RAW DC to AC SI.s Ratio 1.1 Economics Economics Average Cost of Electricity Purchased Average Coat of Electricity Purchased 0.11 61kM soon utility from O611ty Performance Metrics Performance Movies Capacity Factor C....11, Factor 14.4% 17.0% :`:cNREL RESULTS 1,509 kWh per Year 9yslom PvtPaf meY rarga !mm I <O21p f.554hHT per y4w rwa lNa Imetion . w....nan., Zu.... Month Solar Radiation AG Energy Energy Value (kWh l M2 day) (kWh) (S) January 2.31 TO a February 2.91 81 9 March 4.53 134 15 April 5.49 158 18 ,Z'i`,`: May 6.01 175 19 mo.r.no.. vwr. June 6.25 114 19 _ July 6.41 119 20 wer mue.4.vr 1112August S'"166 1s 1-1 .I September 4.91 136 15 October 3.37 99 11 .v.w4, rw.n November 2.83 82 9 srlue.nwrax «r M and. December 1.66 52 6 Annual 4.39 1,510 $ 167 Location and Station identification Roof ... rod Location 11525 W. 38TH AVE, WHEAT RIDGE CO Weamer Data U... RMY3) DENVERICENTENNIAL (GOLDEN - NREL), CO 3.3 mi Latitude 39.74' N Lon9lbads 105.18'11Y .mr. vmvun x rvmxazw+v. PV System Specifications (Residimhap _ X. OC System 51. 1.20 kW Module Type St -dad a Amy Ty" Fived(ops. mck) naruwv¢ v rm Army Tih 26' Amy Azimuth 90' „uM =711.4 Sy.tem Loss.. 14% Inverter EMeieney 96% DC to AC sure RAW 1.1 Economics Average Cost of Electricity Purchased 0.11 SIk", soon utility Performance Metrics Capacity Factor 14.4% NOTES: Cautions for Interpreting Results: Due to variations and the uncertainties associated with the weather data and the Model used to Model the PV performance, future months and years May be encountered where the actual PV performance is less than or greater than the values shown in the table. The variations may be as much as 40% for individual months and up to 20% for individual years. Compared to long-term performance over many years, the values in the table are accurate to within 10% to 12%, cam �,Q �D N N N N V' V' O O M M CD O M M � Lt_ E O O U L 5 V) 0 Y a v F- C C W 3 n3 - 1n 3 3 (U m E = za C s Q Q L Z Ci C3 �7 U W q z 0 92 0 O W 00 QO J S -.4- O LLJ In= 00 c0 0 p�aJ�LrU) C -L0< I Y N W r7 ti��ro �0 JOB NO. 8615 DATE 5/21/17 SHEET N0. 4.O heat R""ge ..:1.1in(7 p1V15�� General Information Surveyor:______ --------------- Date: ------------------------ Weather; Time: ------------------------ Irradiance: -------------------- Cell Temp: -------------------- Ambient Temp: ---------------- Array Azimuth(s);______________ Array Tilt(s):------------------ Net Meter#: o Verify all Labels are Installed ❑ Verify all Covers are Installed ❑ Verify Tools/Trash/Materials are removed Modules S/N Inverter S/N: ❑ Visually Inspect the Array ( s) ❑ Visually Inspect Grounding ❑ Conductivity of Grounding ❑ Verify Polarity at DC Combiner ❑ Measure V DC at DC Combiner Modules/String: /String Modules/String: /String String 1 V DC: / String 2 V DC: / ❑ Inspect Wire Managment ❑ Inspect Conduit/Home Run Voltage at Interconnection: ❑ Turn on Main Disco ❑ Turn on Other AC Disco (s) ❑ Verify Inverter Operation ❑ Note Inverter Readings V DC: A DC: V AC: Hz AC: AC Output (W) Shut System Down as Needed o u e s s co ON 1,D ID (U N N (U 44 0 0 M M C' (`7 0 0 M ch tL L� E 0 _ u d �. O T w 3 — 3 Ji 3 3 W QN [EE" ~ d ` n x Q Q `�° 01ZLLa F d D z o_ JOB N0. 8615 DATE 5/21/17 SHErr NO. 5.0 City of Wheat Ridge Technical Datasheet r• 1 '-INN Silfab SOLAR SILFAB SLA -M 280/285/290/295/300 The Silfab SLA -M 60 -cell monocrystalline module series is the result of the experience of the Silfab technical team, specialized in the entire photovoltaic value chain, with modules produced and operating for over 33 years. The SLA -M, modules are ideal for ground -mount, roof -top and solar tracking installations where maximum power density is preferred. Maximum Efficiency 60 of the highest efficiency, best quality monocrystalline cells result in a maximum power rating of up to 300 Wp. Positive Tolerance (-0/+5W) module sorting achieves the maximum electrical performance of the PV system. Industry Experts Silfab's technical team has specialized experience in the entire photovoltaic value chain, with modules produced and operating for over 33 years. Highest Automation Strict quality controls during each step at one of the world's most automated module production facilities. Increased Quality Top quality materials and 100% EL testing guarantee a trustworthy 25 -year performance warranty. Reduced Weight Engineered to accommodate low load bearing structures while maintaining highly durable mechanical characteristics including a maximum loading of 5400 Pa. Available in Black ®�pDE,N BAA ARRA Z5 ti 2 #ih4r Q TARRIF O,p FREE H�rGH 1 1 1 s-rEneevnnarv.Ee Module product warranty Linear power performance guarantee Product Factory Caution: Read the safety and installation manual before using this product. Third -party generated pan files from PV Evolution Labs are available for 280M, 285M, 290M, 295M and 300M. Sid -fab" SOLAR Silfab Solar Inc. 240 Courtneypark Drive East • Mississauga, Ontario Canada L5T 2S5 Tel +1 905-255-2501 • Fax +1 905-696-0267 info@silfab.ca • www.silfab.ca 12 years Module Power (Pmax) Wp 280 285 290 295 300 Maximum power voltage (Vpmax) V 31.7 32.0 32.4 32.7 32.9 Maximum power current (Ipmax) A 8.83 8.91 8.97 9.04 9.26 Open circuit voltage (Voc) V 38.7 39.1 39.6 40 40.53 Short circuit current (Isc) A 9.40 9.47 9.54 9.61 9.76 Module efficiency % 17.1 17.4 17.8 18.06 18.8 Maximum system voltage (VDC) V 1000 Series fuse rating A 15 Power tolerance Wp -0/+5 Measurement conditions: STC 1000 W/m' • AM 1.5 • Temperature 25 -C • Measurement uncertainty s 3`- • Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by m5% and power by -0/+5W. Rmperature Ratings Temp Coefficient Isc %/K 0.03 Temperature Coefficient Voc %/K -0.30 Temperature Coefficient Pmax %/K -0.38 NOCT (± 2 C) °C 45 Operating_ temperature C -40/+85 "I'MIM11WE 1-1 P14 '111 -Irl IN 10.1 III -M VI F Module weight (± 1 kg) kg 19 Dimensions (H x L x D; ± 1mm) mm 1650 x 990 x 38 Maximum surface load (wind/snow)* N/ml 5400 Hail impact resistance o 25 mm at 83 km/h Cells 60 - Si monocrystalline - 3 or 4 busbar - 156 x 156 mm Glass 3.2 mm high transmittance, tempered, antireflective coating Encapsulant PID -resistant EVA Backsheet Multilayer polyester -based Frame Anodized Al Junction Box 3 diodes-45V/12A,IP67 Cables and connectors* 1200 mm o 5.7 mm (4 mm'), gzx connector, MC4 comparable * See installation manual Module product warranty Linear power performance guarantee Product Factory Caution: Read the safety and installation manual before using this product. Third -party generated pan files from PV Evolution Labs are available for 280M, 285M, 290M, 295M and 300M. Sid -fab" SOLAR Silfab Solar Inc. 240 Courtneypark Drive East • Mississauga, Ontario Canada L5T 2S5 Tel +1 905-255-2501 • Fax +1 905-696-0267 info@silfab.ca • www.silfab.ca Wheat ?idge 12 years 25 years 97% end of 111 year >_ 90% end of 12t1 year >_ 82% end of 25t1 year ULC ORD C1703, UL 1703, IEC 61215, IEC 61730, CEC listed _ UL Fire Rating: Type 2 (Type 1 on request) ISO 9001:2008 CE 0 1, Fraunhofer ISE ors�y.,.al 9 nix tial. elwrn.g-5a � , m � c -c ,.(4 Yew W ] 141 crwrl. StiE ••••,, Wheat ?idge solar =@@ SolarEdge Single Phan for North America SE3000H-US / SE3800H-US > SE5000H SE760OH-US I Optimized installation with HD -Wave technology - Specifically designed to work with power optimizers - Record-breaking efficiency - Integrated arc fault protection for NEC 2011 690.11 and integrated rapid shutdown for NEC 2014 690.12 4 - Extremely small a — High reliability without any electrolytic capacitors — Built-in module -level monitoring wave — Outdoor and indoor installation — Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) USA -CANADA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK -ISRAEL -TURKEY -SOUTH AFRICA -BULGARIA www.solaredge.us solar• • z Single Phase Inverters for North America SE300011-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US Nominal Output Voltage 1 120 V Maximum Output Power1500(2) W ......................................................... ...... _.................. _ ......................I.... ........,. ...... ... .. ............. External Outlet with GFDI Yes ADDITIONAL FEATURES Supported Communication InterfacesR5485, Ethernet, ZigBee (optional) Cellular (optional) Revenue Grade Data, ANSI C12.20 Optionall'i Rapid Shutdown NEC 2014 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety Grid Connection Standards Emissions INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range ...................................................... . DC Input Conduit Size / # of Strings / AWG Range ..... Dimensions with Safety Switch (HxWxD) .......................... _ .. _ .. ........... .......... Weight with Safety Switch ........................................................... Noise ........................................................... . Cooling Operating Temperature Range ........................................................ . Protect on Rating For other regional settings please contact SolarEdge support Depends on PV availability i" Revenue grade inverter p/N: SE—H-US000NNC2 Power de -rating from 50°C is1 40 version P/N: SEx—H-US000NNU4 UL1741, UL16996, CSA C22.2, Canadian AFCI according to T.I.L. M-07 ...................... _.._..__._ ......... IEEE1547, Rule 21, Rule14 (HI) ...... . . .... ................ .... ...... FCC Part 15 Class B 0.75.1" Conduit/ 14-6 AWG . . .... 0.75-1" Conduit /1-2 strings / 14-6 AWG ...................... .. .... ........ 17.7 x 14.6 x 6.8 /450x370x174 .................................................... _ ...... 253 / 11.S ............................................................ < 25 ............................................................ Natural Convection .................. -13 to +140 / -25 to +6Ci4) (-40°F / -40°C option)t5i ............1 ...............9 .... .............. ............ NEMA 311 (Inverter with Safety Switch) F_SE3000H-US _ SE3800H-US I SE5000H-US SE6000H US SE760OH-US OUTPUT Rated AC Power Output ... ............. 3000 I 3800 5000 6000 7600 .. VA Max. AC Power Output 3000 3800 1....... 5000....... 6000 ....... 7600....... .... VA AC Output Voitage Min. -N om.Max. (183 208 229) ✓ Vac AC Output Voltage Min. Nom. Max. (211 240 - 264) ✓ ✓ I ✓ ✓ ✓ Vac AC Fre uenc (Nominal ........ 4............ ............................... 1 .. ...... ... 59.3 - 60 - 60.5 ................. ................ 1 Hz .. .... Maximum Continuous Output Current 208V ( 24 A ..... ........... ... .. .. ... .. .. Maximum Continuous Output Current 240V .... ... .. . ...... ....... 12.5 .................. 16 .... .... 1 21 .. ...... .......... 25 32 ....... A ........ Thres.h.old .................................................................................. 1 ....... . ... ... ...... .. ...... .. A .GTI ........................................... Utility Monitoring . . . , Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power 4650 5900 1. 7750 9300 11800 W Transformer less, Ungrounded ........................... _ ...,. _ .,.................. ... ........ ..... ................................................,.... Yes _ ..... _ .......................... ............. Maximum Input Voltage480 .. . ........ ... Vdc ..... Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V15.5 . ...... .. Adc MaximuminputCurrent 240V 8:5.... 10.5 1 135 16:5 .....20...._. Adc Max. Input Short Circuit Current ..... .. .. ............. ................ .... 45 Adc ........... Reverse Polarity Protection ..... .. ...... .. 1... .... ............ ..... ..............600k>.S...... Yes ....... ... ... ... n Ground Fault IsolationDetection ................. .... ......... .. .......... .. .. .. it y .... .. . ......... ............. Maximum Inverter Efficiency .. ... ..... . . 99 .. 99.2 CEC Weighted Efficiency . ... .... 99 ... ... .......... ................1. ..... ..g ........ P Nighttime Power Consumption I. < 2.5 W SELF-SUSTAINING POWER OUTLET (OPTIONAL) Nominal Output Voltage 1 120 V Maximum Output Power1500(2) W ......................................................... ...... _.................. _ ......................I.... ........,. ...... ... .. ............. External Outlet with GFDI Yes ADDITIONAL FEATURES Supported Communication InterfacesR5485, Ethernet, ZigBee (optional) Cellular (optional) Revenue Grade Data, ANSI C12.20 Optionall'i Rapid Shutdown NEC 2014 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety Grid Connection Standards Emissions INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range ...................................................... . DC Input Conduit Size / # of Strings / AWG Range ..... Dimensions with Safety Switch (HxWxD) .......................... _ .. _ .. ........... .......... Weight with Safety Switch ........................................................... Noise ........................................................... . Cooling Operating Temperature Range ........................................................ . Protect on Rating For other regional settings please contact SolarEdge support Depends on PV availability i" Revenue grade inverter p/N: SE—H-US000NNC2 Power de -rating from 50°C is1 40 version P/N: SEx—H-US000NNU4 UL1741, UL16996, CSA C22.2, Canadian AFCI according to T.I.L. M-07 ...................... _.._..__._ ......... IEEE1547, Rule 21, Rule14 (HI) ...... . . .... ................ .... ...... FCC Part 15 Class B 0.75.1" Conduit/ 14-6 AWG . . .... 0.75-1" Conduit /1-2 strings / 14-6 AWG ...................... .. .... ........ 17.7 x 14.6 x 6.8 /450x370x174 .................................................... _ ...... 253 / 11.S ............................................................ < 25 ............................................................ Natural Convection .................. -13 to +140 / -25 to +6Ci4) (-40°F / -40°C option)t5i ............1 ...............9 .... .............. ............ NEMA 311 (Inverter with Safety Switch) solar- e e : III I'I�IIII�III�IIIIIUIoII� Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents Rapid shutdown cables Micro -SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable Installation Perform this procedure before connecting the strings to the Safety Switch (Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. I0If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the tour Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below'. Use a standard straight -bladed screwdriver to disconnect the cables from the terminals. Switch terminal block Disconnect hero OC connection terminals t �f .( I '' ,.0; ..I 1 -/ .. a e 4 -1. 1 Disconnect here FA -4 TiIF g OW AW l us, -4 bM y_ I J l J -`-Ii p 0 C 0 r iy V NOM * It t3 i Figure 1: Inside the ACIDIC Safety Switch ' The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. Rapid Shutdown Kit Installation - MAN -01-00186-1.6 solar=.. Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 Ib*in): If the cables at the top are red and black from left to right, connect as shown below. Red (+) Black (-) Black (-) Red (+) with rapid shutdown resistor Figure 2: Rapid shutdown cable connected - option 1 If the cables at the top are black and red from left to right, connect as shown below. Black (-) Red (+) Red (+) with rapid Black (-} shutdown resistor Figure 3: Rapid shutdown cable connected - option 2 6 Use a standard straight -bladed screwdriver to connect :he other end of the rapid shutdown cables to the DC connection spring -clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*Ib / 1.2 N*m. fRapid Shutdown Kit Installation - MAN -01-00186-1.6 City of Wheat Ridge Diviso `811 @¢4 OW AW l us, -4 bM y_ I J l J -`-Ii p 0 C 0 r iy V NOM * It t3 i Figure 1: Inside the ACIDIC Safety Switch ' The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. Rapid Shutdown Kit Installation - MAN -01-00186-1.6 solar=.. Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 Ib*in): If the cables at the top are red and black from left to right, connect as shown below. Red (+) Black (-) Black (-) Red (+) with rapid shutdown resistor Figure 2: Rapid shutdown cable connected - option 1 If the cables at the top are black and red from left to right, connect as shown below. Black (-) Red (+) Red (+) with rapid Black (-} shutdown resistor Figure 3: Rapid shutdown cable connected - option 2 6 Use a standard straight -bladed screwdriver to connect :he other end of the rapid shutdown cables to the DC connection spring -clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*Ib / 1.2 N*m. fRapid Shutdown Kit Installation - MAN -01-00186-1.6 City of Wheat Ridge Diviso solar' - • ! = Rapid Shutdown Kit Installation and Configuration (Single Phase Inverters) Inverter Software Compatibility Check and Upgrade Perform this procedure after activating the inverter [Step 1 in Chapter 5: Commissioning the Installation of the SolarEdge Installation Guide], and before pairing (Step 2 in Chapter 5 of the SolarEdge Installation Guide). To use the rapid shutdown feature, the inverter communication board firmware (CPU) must be: • Version 2.0700 or higher, if the CPU version is 2.Oxxx • Version 3.0700 or higher, if the CPU version is 3.Oxxx To check the inverter CPU version: 1 Verify that the inverter has been activated using the activation card supplied with the inverter. 2 Press the LCD light button short presses until the screen below is reached. I D : # # # # # # # # # # D S P 1/ 2: x. x x x x/ x. x x x x C P U 0 0 0 2. 0 7 0 0 C o u n t r y: X X X X X 3 Check the CPU version number. If lower than 2.0700, upgrade the inverter software as described below; otherwise proceed to "Power Optimizer Pairing". To upgrade the inverter software: Use the supplied SD card adapter or the micro -SD card, which can be removed from the adapter, according to the activation card slot on your inverter communication board, labeled 7 Verity that the AC breaker connected to the inverter is OFF. 2 Open the inverter cover's six Allen screws and carefully pull the cover horizontally before lowering it, as described in its manual. 3 Insert the card into the card slot on the communication board. If the communication board has an SD card slot, use the supplied SD card adapter. If there is a micro -SD card slot, remove the micro -SD card from the adaptor and insert it. 4 Close the inverter cover and turn the AC on. If upgrade is required (as described above), it starts automatically. 5 Wait for the message "Done" to be displayed on the LCD. 6 Verify the correct version as described above. 7 Remove the card from the inverter and keep it for additional kit installations. Power Optimizer Pairing Pairing at this stage will reprogram the power optimizers to perform rapid shutdown. 1 Verify that the ON/OFF switch at the bottom of the inverter is OFF. 2 Turn ON the AC breaker and the Safety Switch. 3 Perform Pairing as described in Step 2: Pairing, of Chapter 5: Commissioning of the SolarEdge Installation Guide. Enabling Rapid Shutdown There is an option in setup mode to enable the functionality of rapid shutdown. 7 Verify that the ON/OFF switch at the bottom of the inverter is ON. 2 Enter Setup mode by pressing and holding the LCD light button. 3 Select Maintenance 4 Optimizer Conf. + Set Rapid Shutdown. • Whenever replacing, removing or adding a component in the string, perform Pairing and rapid shutdown setting. Troubleshooting If the inverter does nct enter production mode and the LCD displays Night Mode, the connection order of the rapid shutdown cables may be incorrect. Recheck the cables and make sure that the rapid shutdown cables connected to the bottom of the switch are reversed relative to the cables connected at the top of the switch (see Figure 2 and Figure 3). Rapid Shutdown Kit Installation - MAN -01-00186-1.6 ff City of Wheat Ridge solar=ee SolarEdge Power Opti Module Add -On For North P300 / P320 / P400 / P405 PV power optimization at the module -level — Up to 25% more energy — Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA ISRAEL - AUSTRALIA WWW.SOIaredge.us solar" • • SolarEdge Power Optimizer Module Add -On for North America P300 / P320 / P400 / P405 P300 P320 P400 P405 (for 60 -cell modules) (for high-power (for 72 & 96-ce!I (for thin film 60 -cell modules) modules) modules) INPUT Rated Input DC Powerl'I 300 i 320 400 405 ................ ......... ...... ......I...... —- ......... W Absolute Maximum Input Voltage _..._.....__.. 48 80 125 .. .... 1.- .. Vdc (Vocatlowesttemperature)..................................................................I.I....................... ........................... ............. MPPT Operating Range ................... ..8- 48............................... 8 80... 125 - 105 Vdc ..... Maximum Short Circuit Current (Isc) .. .. .. 10 11 10 . ..... ... ... Adc Maximum DC In ut Current P.. .. ... 12 5 13.75 12.5 .... �............ . Adc Maximum Efficiency 99.5 Weighted Efficiency 98.8 %...... Overvoltage Category II ....... .. OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Double Insulated MC4 Compatible ................................... ... ..Maximum Output Current .......15...................................................... .... Adc..... Maximum Output Voltage 60 1_ 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 Vdc Ootimizer Rated 5TC power of the module. Module of up to +5% power tolerance allowed. STANDARD COMPLIANCE Minimum String Length .. ... . EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 _ -................................ ................. Safety IEC62109-1 (class II safety), UL1741 8 10 18 RoHS Yes (Power Optimizers) .............. INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000. .................................... ....... ............................... Vdc..... Com alible inverters All SolarEdge Single Phase and Three Phase inverters 25 25 50 Dimensions (W x L x H) 128x152x27.5/ 128x152x35/ 128x15 -2x4.8 mm / in ......... - 5x5.97x1.08 5x5.97x1.37 5x597x189 Weight(incIudingcables)......................................770/1:7.......................�........930/2;05...............930/2.05 ............... g�.�.�b.... Input Connector ............... MC4 Compatible ..... .... .. .. . .... ....... .. Output Wire Type / Connector ..... Double Insulated MC4 Compatible ................................... ... Output Wire Length ............ .2/ 3... 9 / 3:0...... 1....2..../............. . ..9. m / ft .. ......... . Operating Temperature Range. ...... .:.9....5 .. ......... -40 - +85 / -40 - +185 ............................................................... .0 / .F ........... Protection Rating IP68 / NEMA6P Relative Humidity 0-100 ........ ............... ... ........... ......... ..I....... .. ........ ............... % Rated 5TC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER [2) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length 8 10 18 (Power Optimizers) .............. ............................................................................................................... .............. Maximum String Length .,(Power Optimizers)... ............. 25 25 50 .. .Maximum Power per String ........... ............... 5250 ............... ....... -....... 6000. ..... .... .... . I ..............12750 .............. ......... - Parallel Strings of Different Lengths or Orientations Yes' Ixl It is not allowed to mix P405 with P300/P400/P600/P700 in one string. Amy La�J OUT • Find the required structural attachment points. Mark these using a vertical (N -S) chalk line on the center of the rafters. Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load areas may require lesser bracket spacing in the E -W axis vs. the maximum spacing. Max spacing is 48"for portrait orientation and 72"for landscape orientation. Consult project layout diagram for project specific bracket spacing on the roof. • Install Rock -It Mounts to predetermined mount spacing. • The array skirt sections are the width of a typical 60 cell module — use the array skirt as a guide to lay out module placement. Note: The distance between the rows of mounts is calculated by the module dimension N -S plus 1 3/8" (35mm). Lag screw should be installed as close to center of exposed shingle as possible. The minimum distance between the lag screw and the edge of the shingle is 1/2". GreenFasTen FLasHinG insTaLL www.ecofastensolar.com 1 Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2 Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. Eco Fasten Solar recommends an EPDM mastic. 3 Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when torqued. 4 Line up pilot hole with GreenFasten flashing hole. Insert the lag bolt through the EPDM bonded washer, the Rock -It slide, the gasketed hole in the flashing and into the rafter. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. *The Engineer of Record shall check capacity of rafter to support lag screw loading. info@ecofastensolar.com 877-859-3947 GrounDinG InFormaTlon The rail -free Rock -It System may be used to mount and ground PV modules that comply with UL 1703, only when that specific module has been evaluated for mounting and grounding, in compliance with the included installation instructions. Note: Grounding lug must be visible to inspectors from the entire perimeter of the PV array. Multiple Use Grounding Pins Grounding pins within the Mid -Clamp are multiple use bonding/grounding devices. Modules will need to be adjusted if the Mid -Clamps are loosened to ensure there is "new" metal to pierce into upon retightening. Grounding Method Rock -It 2.0 Mount bonds N -S rows of modules Rock -It 2.0 Coupling bonds E -W rows of modules Array Skirt 2.0 bonds E -W along the entire array when installed One Burndy CL50-1TN ground lug is required per PV array, limited to 300 modules placed in either portrait or landscape orientation. BonDinG ASSemBL�J anD BonDinG PATH 4 www.ecofastensolar.com Bond Path Grounding Lug - Equipment Grounding Conductor (EGCY generaly to earn 5--d Rock -It Coupling Rock -It Mount Rock -It Array skirt Bond Path I Grounding Lug - Equipment Grounding Conductor (i g.Aym —M r Rock- It Coupling I Rock -It Mount . Rock -It Array Skirt Integrated Bonding info@ecofastensolar.com Bond Path i Grounding Lug - Equipment Grounding Condtxtor(EGC} .-.,.fly to earth ground Rack-lt Coupling Rock -It Mount Rock -It Array Skirt r-fQ 877-85 THermaL EXPansion anD BonDinG A thermal expansion gap is required per each continuous 40' length of modules. Omit a coupling and leave a 2" gap in the array skirt and also between the modules at that point. BracKeT sPacinG Portrait Orientation tt __ _lu - : _ t )t _ it - II 1 Landscape Orientation -- Bond Path Grounding Lug - Equipment Grounding Conductor (EGC} generally to earth grourd Rock -It Coupling ■ Rock -it Mount —Rock -It array Skirt 32mm, 35mm & 40mm Modules: Max east/west bracket spacing is 72"OC. Maximum east/west bracket spacing is 48" OC. 32mm Modules: Max east/west bracket spacing is 48"OC. Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load areas may require lesser spacing E -W than the maximum. STaGGereD Lai OUT Staggered Mounting Points canTILever anD OFFSeT -q Rock -It Mount Rock -It Coupling Cantilever: Maximum cantilever is 1/3 bracket spacing. For portrait orientation installations, check layout prior to installing. The array layout instructions in this installation manual offer a general overview of layout. Periodically, due to a variety of Offset: Offset from all roof edges depends on wind speed, snow factors (roof obstacles, shading, etc.) other layouts are required. loads, local fire and building codes per location www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 13 City of Wheat Ridge uilding Product data sheet DU221 RB CATALOG NUMBER Characteristics SWITCH NOT FUSIBLE GD 240V 30A 2P BYPASS DIMENSIONS NEMA3R LINE LOAD Product availability: Stock - Normally stocked in distribution facility W" H" Price'': 177.00 USD 2 3 Main 5 6 Commercial Status Commercialised OH/UG U4801 -XL -5T9' Product or component Single Throw Safety Switch #6-350 #6-350 type 4% 13 [In] rated current 30 A 3 2'/2 Product certifications UL listed 3 1/4 NEMA degree of NEMA 3R 5 OH/UG protection H.O. #6-350 Disconnector device Non -fusible disconnect LEVER 47/a type t 3 Device composition None 3 3 Device mounting Surface o 7 Number of poles 2 2 0 am H.O. Electrical connection Lugs K LEVER Series name General duty d y 19 3 21/z 3 3 ;� Ordering and shipping details d � a=d Category 00106 - D & DU SW,NEMA3R, 30-200A t c ..� Discount Schedule DE1A = aS =do GTIN 00785901490340 0 Nbr. of units in pkg.1 ° E Package weight(Lbs) 4.62 " a Product availability Stock - Normally stocked in distribution facility € d $ o o 0 Returnability Y Country of origin MX = 24 ° a m v 6 c a 2028 Contractual warranty M, 4,> d Period 18 months .T o A x y 6 w E y o a v a Q `o 2 ny � o o m yca� c ya. m � W c v m c m � $ E o o o t = m m o r. a -aoo � c y m m N Q E y =earn D N C C y C 0 a o � � v L y N y 0 TW a c y c m o v E �t o m N l-41 rnz rL Oct 6, 2014 Schneider &Eleccru 1 MMILBANK' U4551 -RRL 200 AMP -5 & 7 TERMINAL— RINGLESS— 600 VAC 10 � ro I� I 00 a 2 O4 003 aO4 4801 U4801 -XL -5T9 4551 O O O 4701 200 AMP -5 & 7 TERMINAL—RINGLESS — 10 OR 1 303W U4701 -RRL TERM SERVICE CATALOG NUMBER HUB CONNECTORS CU/AL BYPASS DIMENSIONS CONCENTRIC KO'S LINE LOAD D' W" H" 1 2 3 4 5 6 5 OH/UG U4801 -XL -5T9' C.P. #6-350 #6-350 LEVER 4% 13 19 3 2'/2 3 3 1/4 '/4,'/z 5 OH/UG U4551 -RRL H.O. #6-350 #6-350 LEVER 47/a 13 19 3 2'/z 3 3 'A 1/4 1/2 7 OH/UG U4701 -RRL H.O. #6-350 #6-350 LEVER 41A 13 19 3 21/z 3 3 '/4 '/4,'A HUBS: For proper hub selection see the hub suffix chart on the accessory page. BYPASS: Lever bypass and the lever supplies clamping action on jaws. ' FACTORY -INSTALLED FIFTH TERMINAL: Includes factory installed fifth terminal in the 9 o'clock position. 10 City of Wheat Ridge BU (9 Dimon,, i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE 5 it - Inspection Type: ! Job Address: 1/ a 'S v -J Y A v C Permit Number: c)- 0 / 7 p `3'7 10 ❑ No one available for inspection: Time 101,9� AM/PM Re -Inspection required: Yes When correc ions have been made, call for re -inspection at 303 -234 - Date: 6. f ` / 7 Inspector: rm-rH DO NOT REMOVE THIS NOTICE INSPECTION RECORD Occuaancyrrype INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking &Landscaping "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER •- CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office ' (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type PFD ' "f2f• "Llf, Job Address Permit Number la -:W5 _eiLz : Time A Ail spector „�..t° , 3EMOVE THIS NOTICE ♦��4 City of Wheat Ridge Residential Plumbing PERMIT - 102463 PERMIT NO: 102463 ISSUED: 10/27/2010 JOB ADDRESS: 11525 W 38TH AVE EXPIRES: 10/27/2011 DESCRIPTION: Replace 199,000 btu Tankless hot water heater * ** CONTACTS * ** owner 303/635 -8114 Vicky Langholz sub 303/519 -1653 Terry Ross 07 -0007 Plumb Crazy ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0194 BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 2,000.00 FEES Permit Fee 40.00 Total Valuation ,00 1 15, Use Tax 36.00 Sf�" S �. F , ** TOTAL ** 76.00 Conditions: Subject to field inspections. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this appl cation— and,that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other appli able Wheat Ridge Ordinances, for work under this permit. PlAns subject to field inspection. 1 2. 3. 4. S. 6. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1). year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty -four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review &,& subject to field inspections. Signature ,)7` AE Building date INSPECYON REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUES S MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. - �, t)lQhllin.tlt Ili' �7L7YtvlPY i�"��"� Plan 9 Building &inspection Services Division 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303 -235 -2855 * Fax` 303- 237 -8929 Inspection Line: 303 -234 -5933 Building Permit Application Property Adrlti`ess:, — i A E, Property owner (please print): lG� L+G1�L� — y — Phone Mailing Address: (if different than property address) Address: City, State, Zip: Contractors City License #: Phone: 8Gb Gontractorsz - Electrical: Plumbing: Mechanical: City License # City License # City License # be ,ri 1 :t ftari of ikrortsr l S I �ln ^ I IES) �J _� �by� Contract � Value: $ Review Fee (due . at time of submittal): Squares BTUsI M Gallons Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit . application are accurate and do not violate applicable ordinances, rules or regulations of the City . of Wheat Ridge or covenants, easements or restrictions of record;. that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner . or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. - - CIRCLEONE: ( ��OOWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR PRINT NAME. e" t ' D f M � \ SIGNATURE: -- DATE: r s ''r ReV eW�er�y�` .,y�°`'„J. ".� � i fir is �� - '- s ly ✓�� ✓ s����",r �'- � � > ?j {� � ya . J� i s t a! ,; �' s s ,��� .✓L .^� �l3 y�r .: �Y/,.` �' � �, ! �i �� a ;s` ! !�.% ✓�, f n ,,. r fir✓ t?iY r" Ps ! �t �i � ✓ ✓ � r „,r� > i �. - l✓ { - PUBLlG'7/UORK9 � � "; r �" '' �' a i `e �i! 'ii a re � t b ,�"i c' ��� y �✓ j � ,� � ` � � r � � a�. �✓ ✓ e �r �^i �� . ��. FiRI:'UEPARTMEty7� p approv�d eomm�9s� Ll�isapprovsd 17 :'io rowew requ� d Bldg Valuation $ ♦ ♦ CITY OF WHEAT RIDGE �-r Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 235 -2857 Fax INSPECTION NOTICE Inspection Type: ra sto Job Address: / <SfS ,�r• 3rrr ,�� Permit Number: r1 x/372 '7'` l°'.+4- // �� .�' Shf�% i�d,�FCdT % D•� P,v2�odJ ,�-� /¢ ,,C�' �izs'• F t>rsG` lz /Ae ❑ No one available for inspection: Time AM /PM Re- Inspection required: Yes No * When corrections have been made, call for re- inspection at 303 - 234 -5933 Date: 2; ,*afdy Inspector: _ DO NOT REMOVE THIS NOTICE INSPECTION RECORD I !tncvlTVDe 'V LINE: (303) 234- 5933 r s Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. W)T) ' lr _ v -) it INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Plumbing Stemwall / (CEG) Concrete Encased Ground ..�...�. - Reinforcing or Monolithic _ ' Weatherproof / French Drain Sewer Service Lines Building Final Water Service Lines Fire Department POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR Electrical (Underground) Electrical Plumbing (Underground) Plumbing Heating (Underground) ..�...�. :Mechanical Nn NnT POI IP FI OOP IINTII ARnVP HAS HFFNI sirNFO ROUGHS Sheathing Electrical Lath / Wall tie Plumbing Mid -Roof ..�...�. :Mechanical Electrical Service _ ' Rough Electric Rough Plumbing Building Final Gas Piping Fire Department Rough Mechanical - R.O.W & Drainage ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING Framing 'INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping Insulation "'NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED.:FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPAN I Drywall Screw IS IS"''k `O FINALS Electrical Plumbing :Mechanical _ ' Roof Building Final Fire Department - R.O.W & Drainage 'INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping "'NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED.:FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPAN flrri lDAtiry AInT PGPMITTFn I INT II CERTIFICATE OF OCCUPANCY IS IS"''k `O PROTECT THIS CARD FROM THE WEATHER ,t i CITY OF WHEAT RIDGE Building Inspection Division r (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPXCTION NOTICE Inspection Type: i Job Address: I I Permit Number: r ❑ No one available for inspectionn;.~Time AM/PM Re-inspection required: Yes tNo' When corrections have been me a, all for re inspection at 303-2345933 Date: `t o~ t 90inspector. DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division ( f (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 235 -2857 Fax INSPECTION NOTICE Inspection Type: 4 Pry" , vn Job Address: W <V Permit Number: /jl?f2,7;� ❑ No one available for inspection: Time 6 )PM Q Re Inspection required: Yes * When corrections have been made, call for re- inspection at 303 -234 -5933 Date: (C1' Inspector: r 1n DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE �� f� Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 235 -2857 Fax INSPECTION NOTICE Inspection Type: Q ?3 %a Alf,A e'rnr Job Address: Permit Number: 3 al� ❑ No one available for inspection: Time `hFi AM Re- Inspection required: Yes % lo/ "When corrections have been made, call for re- inspection at 3 234 -5933 Date: 2% (��' Inspector: �,.,�:.t" . k� ; Sz.F ' DO NOT REMOVE THIS NOTICE " ' City of Wheat Ridge Residential Roofing PERMIT - 091372 PERMIT NO: 091372 ISSUED:. 08/17/2009 JOB. ADDRESS:.. 11525 W.:38TH.AVE EXPIRES: 02/13/2010 DESCRIPTION: T/o::Replace :25.66 sgs,GAF/ElkTimberline and'redeck.' ***:CONTACTS owner 303/635-6114 Victoria Langholz gC 303/425-7531 John Borfitz 01-9983 J &.K Roofing Inc. **1`PARCEL (INFO ZONE.: CODE: UA :USE: UA SUBDIVISION:.: 0194 BLOCK/LOT#: 0/.: FEE SUMMARY ESTIMATED. PROJECT VALUATION: 10,100.00. FEES Permit Fee `253.90 Permit fee additions. 144.39 Reinspection Fee 61.00S 21 Total Valuation .00 Use Tax 181.80 -TOTAL : 641.09 Conditions: 6 nail installation mid-roof inspection required. Board sheathing spaced more than a 1/2 of an inch apartrequires plywood overlay on entire roof. Ice and water shield required from eave edge to 2':.inside °exterior walls. ` I hereby certify that the setback distances proposed by this permit application. are accurate, and do: not violate applicable sU ordinances,rules or regulations of. the City ofWheat : Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations. made are accurate; that I have read and agree to abide by all :conditions. printed on this F application. and.. that I assume full. responsibility for compliance with the Wheat: Ridge( Building Code (I.B.C) and all other.' applicable WheatRad e Ordi~na~nce~sfo_r work under this p/ermit. Plana subject to field inspection. Signature of ontractor owner ate 1. This permit was issued in accordance with the. provisions set forth in your application and is subject to the'. laws of the `State of Colorado and to the Zoning Regulations and Building Codes of wheat.: Ridge, Colorado or any. other applicable r lordinances of the City. 2. This permit shall expire. 180 days. from the issue date. Requests for an extension must be received prior to expiration date. An extension may. be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be.. acquired for a fee of one-half the amount normally required, provided no changes have been or. will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be (paid for a. new permit. 4. No work of any manner skull be done that will change the natural flow of water causing a drainage.. problem. 5. Contractor shall notify; the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection and before proceeding with successive phases of the job.' ~ . ' 6. The issuance of a permit or the approval of drawings and specifications shall: not be construed to be a permit for, nor an approval of, any violation of the provisions of the-buildingcodes or any other ordinance, law, rule or regulation. All plan review 's 409ect to field inspections. Signature of Ch lding Official date INSPECTIO REQUEST LINE: (303)234-5933 BUILDING OFFICE.: (303)235-2855..' REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. w Y " 1 City of Wheat Ridge sidential Roofing PERMIT - 091372 r4000r- Re PERMIT NO: .091372. _ ISSUED:. 0.8/17/2009 - JOB ADDRESS: 11525. W 38TH AVE EXPIRES: 02/13/2010 DESCRIPTION: T/o:-Replace 25.66. sqs. GAF/ElkTimberline. x** 'CONTACTS owner 303/635-6114 Victoria Langholz sic 303/425-7531 John. Borfitz 01-9983 J.& K Roofing Inc. * * PARCEL INFO * ZONE CODE: UA : USE: UA SUBDIVISION.: 0194 BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 10,100.00 FEES Permit Fee 253.90 Total Valuation .00 y))y Use Tax .181.80 c'ry i TOTAL 435.70 Conditions: 6 mail installation & mid-roof inspection required. Board sheathing spaced more than al/2.ofan inch apart. requires plywood overlay on entire roof. Ice and water shield required from ,eaveedge to.2'--inside :exterior walls. I hereby certify that the setback distances proposed by this. permit. application are accurate, and do not violate applicable ordinances,. rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide. by all conditions printed on this application and that I.assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Rid rdinances, for work under this permit. Plans subject to field inspection. 7-oq Signature of c tractor/ wner date This permit was isa d in accordance with the provisions set forth in your application and issubject to the laws of the State of Colorado and to the Zoning. Regulations and Building Lodes of Wheat Ridge,. Colorado or any other applicable ordinances of the City. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to. expiration date. An extension may be.. granted at the discretion of the. Building Official. If this permit expires, a new permit may be acquired for a fee of one-half.. the amount normally required, provided no changes have been or will be made in the original plans and. specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension. or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work. of. any manner shall be done that 'w ill change. the natural flow of water causing a drainage problem. Contractor shall notify the ;Building Inspector twenty-four (24) hours in advance for all inspections and <shall receive written approval. on inspection card before proceeding with successive phases of the yob. The issuance of apermit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the. building. codes or any. other ordinance, law, rule. or regulation... All plan rev'ew s ect to field inspections. D 'ignature of ief ilding Official date :NSPECTIO REQUEST LINE: .(303)234-5.933 BUILDING OFFICE: (303)235-2855 - :EQUESTS MUST BE MADE BY 3PM-ANY>BUSINESS DAY: FOR INSPECTION THE i. FOLLOWING BUSINESS DAY.. City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 °O<oRSO° Inspection Line: 303-2345933 Building Permit Application Date: Plan fAnnit 5a 5 Cam. Property Owner (please print):.v tC4~G z L Mailing Address: (if different than property address) Address: Phone: 3°3-b35-~-t1'4~ City, State, Zip: .__-'(AC n , C(7-, ~~m -S T~_~41 VA Contractor License 1'0 2275 Phone: 3c,3- ,4as- -?n t pany Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of s ace descti tion): crv_C__ Construction value: $ ) 01 C)a,Crz7 (as calculated per the Building Valuation Data sheet) ' Plan Review due at time of submittal: $ G~C9_~ aS(sCe t~1 ~nhA.-~(Ef~c--l~uv~.~iv~ td03cl Sq. Ft.lL.Ftadded: Squares aS46 BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restdctions of record; that all measurements-shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and thatkassume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans sulect-to-fietd::insp-ecti-on. CIRLCE ONE:: PRINT NAME: PERSONAL SIGNATURE: of (OWNER) (CONTRATOR) -6 1 Date: l 4NV0~\NHEJQ City of Wheat Ridge Residential Electric PERMIT - 071207 PERMIT NO: 071207 ISSUED: 11/05/2007 JOB ADDRESS: 11525 W 38TH AVE EXPIRES: . O5/03/2008 DESCRIPTION: Electric to detached garage. (15 amps) CONTACTS owner 303/667-3807 Vicky Langholz PARCEL INFO ZONE CODE: UA USE: U SUBDIVISION: 0194 BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 150.00 FEES Permit Fee 30.55 Total Valuation .00 UseTax 2.70 TOTAL 33.25 Comments Must comply w/ 2005 NEC and 2003 IRC I hereby certi£y that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions o£ record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the wheat Ridge Building Code (I.B.C) and all other a~plixable Wheat Aidge Ordynanres, for work under this perm;.t. Plans sobject to field inspection. 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes ofWheat Ridge, Colorado or any other applicable. ordinances of the City. 2. This permit shall expire 180 days Erom the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. . 3. If this permit expires, a new permiC may be acquired for a fee oF one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (i) year. I£ changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-£our (24) hours in advance for all inspections and shall receive written approval on inspection card beEore proceeding with successive phases of the job. 6. The issuance of a permit or the apprwal of drawings and specifications sha11 not be construed to be a permit for, nor an approval of, n violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All pla e s subject to field inspections. Signature C f Building Official date INSPEC ION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MFaDE BY 3PMANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. WHEql oF City of Wheat Ridge Building Division m 7500 W. 291h Ave., Wheat Ridge, CO 80033 . Office: 303-235-2855 ' Fax: 303-235-2857 ~o o~POO O Inspection Line: 303-234-5933 Property Address: Building Permit Application ~zI3' 2 5 L,) '3 e "evvy-, = Property Owner (please print): Mailing Address: (if different than properfy address) Address: 5 Date: Plan Permit Phone: 30 3807. City State zip ' Contractor Contractor License Phone: Sub Contractors: Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction Value: $ /450 DeSCriptlon of Work: (as calculated perthe Building Valuatlon Data sheet) 40 '74~1'~ y ~ Plan Review (due at time of su6mrttal): 8 s Sq. Ft./L.Ft added: Squares BTU's Gailons Amps 15 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that Ihave read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance wifh the Wheat Ridge Building Code (I.B.C) ~i 1 all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to fleld inspection. CIRLCEONE'(((////~~~' WNER) (CONTRACTOR) or PERSONALREI PRINT NAME: v SIGNATURE: Date: ZONING COMMENTS: Zoning: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: OCCUPANCY:_ DEPARTMENT USE ONLY BUILDIN6DEPARTMENTCOMMENTS . . Reviewec FIRE DEPARTMENT:: 0 approved w/ Commenls ❑ disapprovetl O no reviewrequired Bldg Valu~ oF wHEarq. City of Wheat Ridge C0 t 0 RPV0 Residential Mechanic PERMIT - 070927 IRMIT NO: 070927 ISSUED: 08/31/2007 ,B ADDRESS: 11525 W 38TH AVE EXPIRES: 02/27/2008 ISCRIPTION: Replace furnace w/ 70K BTU 800& 200A O.H. service; furn circ wo CONTACTS ***)wner 303/635-6114 4c 303/458-5988 ~ub 303/458-5988 Vickie Longhole Josh Ward 01-8236 Applewood Plumbing & Heating & Josh Ward 01-8236 Applewood Plumbing & Heating & * PARCEL INFO ONE CODE: UA UBDIVISION: 0194 USE: r-3 BLOCK/LOT#: 0/ * FEE SUMMARY Permit Fee Total Valuation Use Tax TOTAL ESTIMATED PROJECT VALUATION: 6,930.00 FEES 181.10 .00 124.74 305.84 PRESCRIPTIVE ENE€~GY .OC~E Repiacement boilers/fumaCes - N1inim„n 3"%AFUE s: Setback Thermostat required (Except for hydronic Heat) Gas Water Heaters - Minimum of 60 Energy Factor Electric Water Heaters - Minimum of .93 Energy factor Insulation reauirements: ■ R-21 Wails ■ R-38 Ceilings • R-19 Crawl Spaces ■ R-19 easement walls I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ~ordinances,nules or regulations of the City oE Wheat Aidge or covenants, easements or restrictions of record; tha[ all measurements shown,. and allegations made are accurate; that I have read and agree to abide by all conditions printed on this '.application and that I ssume full iesponsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all oChex ~applicac~ Wheat Rice Ordi'Rances, for work under this pexmit. Plans subject to field inspection. n5Cure of contracmr/owner Oace This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire 160 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. If this permit espires, a new permit may be acguired for a fee of one-half the amount nosmally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) yeaz. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance £or all inspections and shall receive written approval on inspection card beEOre proceeding with successive phases of the job. The issuance.of a permit or the approval o£ drawings and specifications shall not be construed to be a permit £or, nor an approval of, any v olation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan reviw Xp ect to field inspections. OTTicial QdLE WREQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY - COMMUNITY DEVELOPMENT DEPARTMENT oF WHEqT,~ gUILDING iP1SPECTiOId LINE -303-2345933 ~ o CITY OF WHEAT RIDGE ° " 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) ~OCORPO~ li'lINQR [`il-Pi Building PermR Number.. Date: Property Owner:vt&i2. LO TikU Property Address: 115-gg- w , 3 $ Ae- Contractor License No.: ~ell-3 61 Company:A,ateWaF,) ?iowebe..i k Phone:303 Elrzh-, L Phone:3J0 ' S'r8t' OWNERICON7RACTOR SIGNATURE OF UNDfRSTANDING AND AGREEMENT . I Sui/dina Depf. Vafuatiorr Figure: I hereby certify ihat the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the Ciry of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all condiGons printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Builtling Cade (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under thi~jnrmit. Plans subjec4 to field inspection. (OW NER)(CON7RACTOR): V31Ue:$ Permit Fee:$ Pian Review Fee:$ TOt31: $ Use of Space (description): Description ofwork: ~ep(ctcz ft~+SiiNf ~trfN«cc w117~ ~t1Kb`'i e~crr"ace , ~~}wtP Dfulaec.~ Cja, ad d c&d,a,/e-d Circo,tL,,r- heti; -rur,.i Sq.Ft.added Electrical License No: Plumhing License No: Mechanical License No: Company~:Rep(e~+~Pia~^b'~ Company: Company:~p~Zzwve? puwb'" Hea" t E7ec,h-<- Q"57e4-1r - Expiration Date: Expiration Date: Expiration Date: Approval' Approval: Approval: (1) This permit was issued in accordance with the provisions set forth in your appliralion and is subject to the laws of the State of Coforado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinan4es of the City. (2) This pertnit shall expire 180 days from the issue date. Requests for an extension must be received pdor to expiration date.. An extension may be granted at the discrefion of the Building Official. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount nortnally required, pmdded no changes have been or witl be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds ane (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that witl change the natural flow of wffier causing a drainage problem. (5) Contractor shall notify the Building Inspector iweMy-four (24) hours in advance for all inspections and shali receive written approvdl on inspection card before proceeding witli successive phases of the job. (6) The issuance of a pertnit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of ihe provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject . 8o field inspections. INSPECTION RECORD 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 (303) 235-3855 /nspection Line (303J 234-5933 Inspections will not be made unless this card is posted on the building site 24 Hours notice required for inspections Job Address [1,52-6 W. 3~+ Building Pe mit No. :2~1 L Owner e-, Contractor ea0 u su Contractor A d s Issued Type Occupancy INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE APPROVAL DISAPPROVAL INSPECTOR INITIALS COMMENTS: Footings/Caissons Stemwall Reinforcing or Monolithic Weatherproof / French Drain Water/Sewer Service Lines POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED Electrical Service Rough Electric Rough Plumbing Air Test Gas Piping Rough Mechanical Framing Roofing Insulation Drywall Screw FINALS Electrical Plumbing Mechanical Frame / Interior Finish R.O.W & Drainage Fire Department Parking & Landscaping **NOTE: ADDITIONAL INSPECTIONS/ COMMENTS ON BACK OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER Place in Visible Location for Inspector ADDITIONAL COMMENTS & INSPECTIONS: C (/lv~ Ok7 ~)-z 4FE City of Wheat Ridge Res. Add Structure PERMIT - 071037 PERMIT NO: 071037 ISSUED: 09/24/2007 JOB ADDRESS: 11525 W 38TH AVE EXPIRES: 03/22/2008 DESCRIPTION: FREESTANDING GARAGE PER ATTACHED CONTACTS GC 303/238-8571 ORDEAN IBSEN 07-0167 71AA TAURUS CONSTRUCTION LLC OWNER 303/635-6114 VICTORIA LANGHOLZ PARCEL INFO ZONE CODE: R-lA USE: r/3 SUBDIVISION: 0194 BLOCK/LOT#: 0/ Comments: AT: OKAY R-1A JS: PER NOTES ON PLANS SUBJECT TO FIELD INSPECTIONS I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements sriown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume Eull responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat~Ridge~' ances,~Ler this permit. Plans subject to field inspection. Signature bf cq¢YiapEor/owffgY/ date ~ 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Huilding Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to ezpiration date. An extension may be granCed at the discretion oE the Building Official. 3. I£ this permit espires, a new pesmit may be acquired Eor a fee of one-half the amount normally required, provided no changes have been or will be made in Che original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspectiovs and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval oE drawings and specifications shall not Se construed to be a permit for, nor the building codes or any other ordinance, law, rule or regulation. f an approval of, any violation o£ the w All plan review is subject to Eield Signature of Chief Building Official date INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. NOtE°o Owner / con r is rosponsibte fot Yocating Preperty lines and consteucting improvements according W thc approve3 ptan and tequired development standards. T;ie City is not responsible for inaccurate informa:ion __-.s ci ed within the plan set and any construction ;zsultng from inac,:eratc inforr.~uiion. COMMUNITY DEVELOPM.ENT DEPARTMENT Building Permit Number. BUILDING INSPECTION LINE - 303-234-5933 Date: . ~ a CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE PLAN WHEAT RIDGE, CO 80033 - (303-235-2855) . ~~~oRpo~ MINa~ APPLICA-LA"n~ . . Property Owner: V1 e-iaR1F{- a✓c~ti ;c'; 6~$. Properiy Address: ~ j S,~hr t~) 's~`L, W V G" Phone: 363 6 ;j ,r F~ )N Contractor License No.: p lkpl a 38 / Company: ~~1fF TALAKd._S Co/ t'J S"i^Qct.MJ- 6 f`1 Phone: 263 _36*i~f OWNEWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Buildina Dept. Valuafion Figure:- $I hereby ceNfy that the setback distances proposed by this permit application are - accurate, and do not violate applicable ordinances, rules or regulations of the City of . v~~ o0 ~ WheatRidgeorcovenanis,easementsorrestrictionsofrecord:thatallm88suremenis shown, and allegadons made are accurate; that I have read and agree to abide by all PCl"1Tllt conditioos printed on this application- and that I assume full resPonsitirry rar plan Review Fee:$ 1"0.$`1. compliance with the Wheat Ridge Building Code (I.B.C) and all ofherapplicable Wheat Ridge Ordinances, for work under this permit Plans subjec field inspection. - USC T2X: L (OWNER)(CONTRALTOR):SIGNED b, - E TOtAl.$ SN C (OWNER)(CONTRACTOR):PRINTEDASON VN`~NDATE~~ S 07 Use of Space (description): 17~e`cSTM/A-114- C's'~FRAY~' Description of work: Sq. Ft. added `7 Vo S O ~ BUILDING DEPARTMENT USE ONLY . SIG: 5. ONMG COMMENTS . - ~ - Approval: Zoning:R4r BUILDINGCOMMENTS: - ~ .~'1 ~C ♦ Approval: PUBLIC WORKS COMMENTS Approval: - IRE DEPARTMENT COMMENTS: AppYOVaC ~ Occupancy: Walls Roof: Stories: - Residential Units: Electrical License No: Plumbing License No: Mechanical License Na: Company: Company: Company: Expiration Date: Expiration Date; Expiration Date: ApprovaL ApprovaL Approval: .('F) - This permil was-issued in accordance with the provisions se[ forth in your application and is subject to the laws of the State of . Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Cobrado or any other applicable ordinances of - the City. - (2) This permit shall expire if(A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building - authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new pertnit may be acquired for a fee of one-half the amowt normally required, provided no changes have been or will be made.in the original plans and specifications and any suspension or abandonment has notezceeded one . . . (1) yeac If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid fora new permit. (4) No work of any manner shall be done that will change the natural Flow of water causing a drainage problem. - - - (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written . approval on inspectioncard before proceeding with successive phases of thejob. . - - : - . . . . (6) The issuance of a permit or the approvat of drawings and specifications shall notbe construed.to be a permit for;-noran - - approvalof,anyviolation-oftheprovisionsofthebuildingcodesoranyotherordinance,law,ruleorregulation.Allplanreview- - (s subject to field irispections. Chief Building Official How to Use this Guide Provide two sets of plans and complete the following: 1 COIi1pICtB tI11S Bl11I1I111J GUIIIB by filling in the blanks on page two and three, and indicating which construction details will be used. 2 PI'OVIdC 2 PlOt Pl811S (site plan) showing dimensfons of your project or addition and its relationship to existing buildings or structures on the property and the distance to existing property lines, drawn to scale. 3 Fill out a building permit application. The majority of permit applications are processed with little delay. The submitted documents will help determine if the - project is in compliance with building safety codes, zoning ordinances and ! other applicable laws. The Colorado Chapter of the Intemational Code Council is a professional ~ t t the ublic ~ organrza ion see mg o promo e heaith, safery and welfare to building construction. We appreciate your feedback and suggestions. To obtain a master copy of this building guide, please write to the Colorado Chapter of the Intemational Code Council, P.O. Box 961, Arvada, CO 80001: - This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2000 International Residentiai Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. City of'Wkeat ~'d8e of w~e,, Building ~Divisian i ° 7500`W 29`~Ave. ~ 'DVheat l2,irCge, CO 80033 (303)235-2855 ~0(pµp~~ 1 0 Building Guide Colorado Chapter of the International Code Council s/i e/ox m Directions . Fill in the bianks on pages 2 and 3 with d'unensions and materials which will be used to build the structure. Please printlegibiy. 2. Indicate in the check boxes on page 3 which detail from page 4 will be used. Note: Heated garages may reguire special provisions. D'unension '90 Locate and Indicate rafter or detail bracing l . truss direction ❑ Sarage is heated Pd'Garage is not heated Show door and window header sizes and location and size of landing in front of door Double 2x4 or 2x6 trimmers each ~ end of overhead door header = Garaqe door opening Garage door opening width &I'l_ ~ * 2' 8" minimum, with I ood sheathin on outside of entire wall Dimensi0n* ~ DimensiOn ~ With hold downs. If less ~ n 2' 8", engineering may be required. _ This handout was developed by the Colorado Chapter of the ay(,~~ ~g~ V International Code Council as a basic plan submittal under 1 aV~U s~{'y(,~-,TV~ 1 I,L- rtb the 2000 International Residential Code. it is not intended ~C~~ N& 1~~ o~ ~ "~..,I. ,~,~1~ to cover all circumstances. Check with your Department of 1 BuildingSafety for additional requirements. ~,q_,~L{, Ir,ei ~^~Jr ~°u«' 6118102 m or cax -0r-zx ~(L5 Minimuml~ ' oar (example: 1 x 12) ~ STVD~S solid or greater) Note: Pre-engineered roof trusses w/truss clips and hardened nails may be used'n lieu of roof shucture shown. ~tLC Diagonal wind bracing or plywood shear panel§ JolC~ corners and each 25' of walL ~/IH- pitch 11~ -l Ceiling Insulation ~ pfheated-example: R38) I 2x_ceiling joists @ _O.C. I I (example:2x 8 @ 24'O.C.) Double 2x~top plate (example: 2 x 6) Span~ ~ `s " (example: 23'5') Ceiling height 8' ~ /example: 8') sidin,g T-!I~ (example: lap orT-117) 42x-1--studs @_21~ ' O.C. (exam0le: 2 x 8 @ 24'O.C.) A B . j lCont. 2x_J -si11 plate I (example:2x6) ~ Wa1llnsulation /,//IF (iiheated - example: Rd9 Fiberglass Betts) Footing size r"/aC' (example: e'x i6) This handout was developed by the Colorado Chapter of the - Internationai Code Council as a basic plan submittal under the 2000 International ResidLntial Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. 3 s/i8/o2 m Lap siding over foundation a minimum of 1". Finished grade Note: Check with local building department for swelliny soils. Caissons may be required. 6" min. 8" Lap siding over foundation a minimum of 1" Finished grade 6" min. 36" min. Note: Check with local building department for swelling soils. Caissons may be required. This handout was developed by the Coloredo Chapter of the International Code Council as a basic plan submittal under the 2000 International Residential Code. It is not intended to cover all circumstances. Check with your Department of BuiMing Safety for additional requirements. 1/2' x 10" steel anchor bolts 6'-0" O.C. max., 7" min. penetration max.12" from corner and 12" from each end of plate. / Bottom plate sh'1a ie min. 8" above grade, or be treated wood or decay resistive wood 31h" Minimum Concrete Slab #4 rebar min. cont. top & bottom '/z" x 10" steel anchor bolts 6'-0" O.C. max., 7" min. penetration max.12" from corner and 12" from each end of plate Bottom plate shall be min. 8" above grade, or be treated wood or decay resistive wood 31h" Minimum concrete slab Fiberboard expansion joint Provide #4 rebarvert. @ 4'-0" O.C. insert rebar into concrete footing or key way 3" #4 rebar min. continuous top of stemwall & at footing 4 Sample Site Plan ' PropertyLi:e~• t ~ • • F ee ~ . ~ ' Garage or Garport or ~ Shed 1 I' ~ J L ~ O I ~ I R i HOUSE ~ ~ 0 ~ ' 5140 5etback Sfde 5etba6 I U ~ ~ N ~ c 0 51DEWALK I . ~ + i NOIZTH 5cale:l"=_ ~ ~ List square footage of AIJ, EXISTING and . PfLOPOSED 5tructures ~ located on the property, ~ ~ i ~ I I II STREET S ~..+y, I4VV.a• VscZOua L.A,,+GNoiz 115~5 47.38Tan Gs7arcAM10401 a, T0:3032352857 i ~i~nPcSla f ay' i , , ~ M1 I ~ i P.2 i ~ ~F7'-~ ESN n-~ ~x. I , 1 I loi 02:4aP FROM: c~G o .Yc /d' 3 eTN /I' ✓ 'r. 5E P-5~-2007 02_40P FROM: 111 T0:3032352657 P.3 ~o>kr~ ~a~~ 9 ~ ~ U B DIVI S10- -N I 1 t/ :~'i _ _ I ~ oo.o W . a`'°• -~~"~~4?T- t1~° I 4 i~S 3 !O ~ 5 ; ~I& I f ~ i ~_1 1 • - . ..r4' ' . i . I sw m.e. ~ ~o....,. e...s..... ~~»•'En:.:uc> G ~ _ I.IRM~'fiN x.4,.N 1 I 1 5 AP•PROVALS .6~ MI.VIN~A LS PaOf R~O~ A~PI~CVBD EY TN6 ..IGii~/~bN ~AYNYV PIIYiN~1b CGNN~ • ~pJfcr tlts~enowi. ~eN TMI! ov 06<Wwr~n.A•O.~ 1962. ~ lC,'~ - LIYNf~ ♦ WIOL~ 1~ RL16RV10 S6CRCTI~AY ~~CIMIl1MAN w ~r •snt u«u wr~~' w unu ~+~~wnew ~~+o ~u~^~' TMa w%mrc Yur n w4:crtco wa owra wno muvarwec ow ~e wnwea rnrnc Iu . wcec►rco ar ~rN6 ~~w a~NT'~ . cewwucn.ras os Jveanor Cw++*v TM~+ ~-owr er DreEnSWa,. A.0.~19f.2: wwx~ ro'*ME TM.Y rwc enwTV srw«. rur wawc'wr.a tnc rw~~rtc~awuea o~ ..o wcNo. ~wr.~ sw~s- r~crwr c w~r rHa~uor ~r tx~1WIAVI~~?7 / t Cw.~ne.wn C~.[w.m !i.`.~7' S58 qeccrKO ►aa ►tuw* Iw rwE eencr on , ►RT T APPRflvALS nne"A`a..~:wo., `is °z.°" p •T G.iJ1L.M. nm Josxwsw Cau~rtv Ewa~wuR+H~ ~.~iX^. /~'s'+`-"`-°'~^ QLIiK /~MO ~-'O~Oi4 Jv Csuwrr Huurr em,.. ,P...~ y . RcesrvioNo. 4rR4;sP N• ltt2-Ca _ - L AAA TAURUS CONSTRUCTION, 1510 Glenayr Dr. #1 Lakewood, CO 80215 Phone: (303) 238-8571 Fax: (303) 274-9713 lame z/ir r~ /vj Phone:Res3~°'~ 63Ls BuS ,ddress Cityll~/li e(!:fZip. ~ 'we, the owners oi the premises described below, hereinafter reterred to as "Purchaser" offer to contrect with NAA TAURUS COMSTRUCTION, LLC. AN AUTHORIZED CONTRACTOR), hereinafter referred to as "Contrectol", to furnish, to deliver and arrange for installation of all materials necessary to nprove the premises located at i~noon City) (LIP) SPECIFICATIONS materials will be furnished and installed to these specifications: according to the (ollowing specifications: ~O2~T/~UCT- [(v 0 i9 4:7.¢,~ -nl- eS L✓~. ~ n o ~ r ~ nr-- ~ n r~ r ~i -ri1.✓ uP ~ ZZA dL A OQ / ~ , ll4"yi1 4- /J~QL~ci Cn,YI 0-4 i LLC Job No.: S.S. No.;!T-7L/ --2 y-~,IW yV;M*2~7- 8/- (',~,c e14- o7'~- .A-" fv)~o 5~~ ry' N i ~ q I ay' 38 ' fi~-xfsr/Ns aausx ~/1 (TVRi/fL3NhNOLz, !1S2'574V 38T~`}rc Q 21 1 l,o> 2 shvd ~ /a L~o~1 I~----- 3 ~ ' --,r . ~ 7 SifEU 12rs r !U/j 1 ~ DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: MILLER RITA M Property Address : 11525 38TH AV Contractor License No. : Company : OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the Ciry of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that 1 assume full responsibility for wmpliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR)SIGNED,DATE F-95--9S Description : PLUMBING-INSTALL FIXTURES IN EXISTING STORAGE AREA; CONSTRUCT FENCE Building Permit Number : 95-1723 Date :8/25195 Phone: 940-3267 Phone: Construction Value : $1,800.00 Permit Fee : $41.00 Plan Review Fee : $0.00 Use Tax : $45.00 Total: $86.00 Electrical License No : Company: Plumbing License No : Company : Mechanical License No : Company : Expiration Date : Approval: Expiration Date : Approval: Expiration Date : Approval: (i) This permit was issued in accordance with the provisions set forth in yopur applicalion and is subjec[ to the laws of the Siate of Coloratlo and to the Zoning Re9ulations and Building Code of Wneat Ridge, Coloredo or any other applicable ordinances of the City . (2) This pertnit shall expire if (A) the work aufhonzed is not commenced within sia1y (60) days from issue date or (B) the builtling authorized is suspended or abandoned for a period of 120 tlays. (3) If this pertnit ezpires, a new permit may be acquired for a fee of one-half ihe amount normally required, providetl no changes have been or will be matle in the original plans and specifcations and any suspension or abantlonmen[ has not exceeded one (i) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be aitl for a new pertnit. (4) No work of any manner shall be done th pat will change the natural flow of wa[er causing a dreinage problem. (5) Contrector shall notiry the Building Inspector twenty-four (24) hours in advance for all inspecfions and shall receive written approval on inspec[ion card 6efore ~.~,.y r........,. (6) he issuance of a permit or the approval oF drawinqs and speci5cations shall not be construed to be a permit for, nor an approval of, any violafion of the provisions af the buildina codes or anv ofher o[dinance, law, rule or regulation. Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION ~~S DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : ;?~ta Ih • /11 Property Address : llSas W. 39 "1Phone : 94/0-31-67 Contractor License No. : wnr~by home oa-ne~s Company : N/<F Phone : iu/.4 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and ali other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONCTOR) SIGNED DATE ~ Ls~s ~r. ~d n4(~_ ~`rsf~✓/ a ~~lef a..d sin/~ ~n L-x/.sT••~ _ . ~~PlUnebiny li,.>r!c 1/0 Descriptiona~C'!Illrra ~errce. mmmval : ~ Zoning : lz•(F, Approval : Approval : Occupancy : Walls BUILDING DEPARTMENT USE ONLY ..WP2:sJa- ~0~r 6~ PYtiv4ty ~E~~~' tO VW--,t_ h+s7 4itvE ~c.e ~,,.LrN [f`~ ~n.oNr PrwJ'Gn-t`l u ME . lfdc.> 4.P40 Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company: Company: Company: Expiration Date : Expiration Date : Expiration Date : Approval : Approval : Approval : 2g pP~~~sHLo ,PIa-C1~;,Requued':. (i) This permit was issued in acwrdance with the provisions set forth in yopur applicalion and is subject to the laws of the State of Colorado and to the Zonin9 Regulations and Building Code of VJheat Ritlge, Coloratlo or any other applicable ortlinances bf the Ciry. (2) This permit shall expire if (A) the work authonzetl is nm commenced within sixty (bo) days from issue date or (B) the building authonzed is suspended or abandoned for a period of 120 days. (3) If lhis pertn0 ezpires, a new permit may be acquired tor a fee of one-half the amount normally required, provitled no chan9es have been or wili 6e matle in the original plans and specifications and any suspension or abantlonment has not exceedetl one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall 6e paid for a new permit. . (4) Mo work of any manner shall be done that will change the natural Flow of water causing a tlrainage pmblem. (5) Contractor shall notify the Builtling Inspector Rvenry-four (24) hours in advance for all inspeclions antl shall receive wntten approval on inspection card 6efore pmceediing with successive phases ot the job. (6) The issuance of a permit or the approval of drawings antl specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions . of the builtling cotles or any other ordinance. law, rule or regulation. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION 00 n o R o s rn ~ O d roy J, o~ i~ 4 t 3 ~j ro m a m rt'r* " m r- rn H GG a~3 ~;'_IV CmB O ri r-~. 0 m N-n cta h .'T' N N ~-O CYN ~~t" 7 ]~n ; r p p w o[t m i-' C o' • - nF` 0 cwnP•mCA K; m a::r n rt NM m Lo Elamo~3- m~lo' ~n2~]n Llk nmrt~ni (D n rtN I rrp rr~ ummmmNP-rtw~ r - i CTp.~ N M G aM~ w~• G Ui~ o n K m~mo° 1 ~OrrH'm rr; O tn ~ ~r rt+C ~V, ra m x m rt~vro rt R~G x i ~ ro ~ t , rt ~ :31 • mawmm 4 P. (D 't7 (D m X O' N rt Nf](1wGNI m w n ~vv i~a.rta g N w. rt N c1 :3" z7 ~3 t-'•N (DC0C7?rt0 rr~:j Q.xrrmwm c Q. nP- a- rtP. m nP•vmrm rt a n on z7 ~-:3o r• m N Ma ri,"G NryrtN r~:jr N fD F'• G O F'- P• a U7 N n O rt Ul ~:s H W` tn Np~:l(D::3 OO ° naK E m m ro`r wri- a r* c rr H o OU'GO ~ ~ . Gp'5` w L H N'O rt ~J O F'i or Q+ C1 ~ artn :r m <mm m cm ow - m Nn ~ ~-xm rt a o.~m n ~ '~J N 3 rtFS fD IU r C i-n La n m::r m (n n r• m r- m p m nom~e o w r*hmK<o. a ~5 r-m m p~m zl rt ~ m rta'ac ~m owP•mmroa 2~ o~ ry n o'n o rt~ ao mm r*~ m En d t m rz7 0 rrw :5 tlK wrr„n . r 10 K ~ 0 10 F p O'U ECI:3 ~ rn w r• m m c~ n rtrmrr ~ ~ a m K ~j P-o ~ P. rt ~vs ~j m ~ Q~ H A 1 0 r ro n 0 v N n rt ~ p 0 rt r• ~ M r O O fl, b N a ~ cD ro m n N O N 3 ~ o c~i 0 W ~1 4 ~m ~ '$n ~ ~N m ~ ~(0 o:5E :~E ~ 2 D (q ~ ~ 0 ~ ~ ~ E -C G~ ~ ~ m c) 7 z AO ~Q m 'o r o~o ~go nm Z ;Ou Fq N A~~ rn n m A ~ n z ~ < t27 E--- z s . N ~ Q N 318' - I J 15~ J N ~ 0 n ~ ~ C7 S m N Y V, rri II Q z m M ~ O➢ a~ ~ ~ 0 C ~ ~ O ~ ~ rb~7 H ~ ~M N H H r~ L J 0 n _ ~ ~ O m H V c ~ ~ ~ DE?ARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : 95-1489 Date :7/24/95 Property Owner: MILLER RITA M Property Address : 11525 38TH AV Contractor License No. : Company: Phone : 456-9179 Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the Ciry of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for c pliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable W,ttqat Ri~g or; in~yce~, for work under this permit. (OWNER)(CONTRACTOR) Description : SHED Construction Vaiue : $300.00 Permit Fee : $15.00 Plan Review Fee : $0.00 Use Tax : $4.50 ~ Total: $19.50 BUILDING DEPARTMENT USE ONLY .n , . Approvai : JE 07124195 Zoning : R-7A Approvai : nommisimmomm Approval: Occupancy : Walls 5' side and 5' rear setbacks Roof : Stories : Residential Units : Electricai License No : Plumbing License No : Mechanical License No : Company: Company: Company: Expiration Date : Expiration Date : Expiration Date : Approvai : Approval : Approval : offmom , , °u~~mwm (1) This permit was issued in accordance with the provisions set foM in yopur application antl is subject [o the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall ezpire if (A) ihe work authorizetl is no[ commencetl within sixty (60) days hom issue date or (B) the buildin9 authorizetl is suspended or abandonetl for a penod of 120 days. (3) If this permi[ expires, a new permit may be acquired for a fee of one-half the amount nortnally required, providetl no changes have been or will be made in the original plans and specifcations and any suspension or abantlonment has not exceeded one (1) year. If chan9es are made or if suspension or abantlonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done tha[ will change ihe naturel flow of water causin9 a dreinage pro6lem. (5) Contractor shall nolify the Building Inspector hventy-four (24) hours in atlvance for all inspeciions and shall receive written approval on inspec[ion card before . proceediingwithsuccessive phasesofthejob. (6) The issuance of a permit orihe approval of drewings and specifications shall not be consWed to be a permitfor, nor an approval of, any violation oFthe provisions of the building codes or any o er ordinance, law, rule or regulation. quvv. Ai~ Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION M4~ 7~ `y~T DEPARTMENT OF PLANNING AND DEVELOPMENT " BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : Date : 7-a i-, 5 Property Owner Property Address Contractor License No. Company >~tA M;ll~~z I/SZS u/ 38~ ~-v-e- ,~/,4 Nf/+ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this pertnit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurete; that I have read and agree to abide by all wnditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE q' I-Y 5 Description : S/tec( (8''X 8'~ as ,S~ourr/ on /Jhc~ BUILDING DEPARTMENT USE ONLY amammmum APProval : ".r) / 5-! Gr G- Zaning : Ox MENNERKME Approval : Approval : Occupancy: Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company: Company: Company: Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: A q (1) This permit was issuetl in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Cobrado antl [o the Zoning Regulalions and Building Code of Wheat Ridge, Cobrado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commencetl within sixty (60) tlays from issue date or (B) the building au[horized is suspended or abandoned for a penotl of 720 tlays. (3) If this permit expires, a new permit may be acquiretl for a iee of one-half ihe amount normally required, provided no changes have been orwill be made in ihe onginal plans antl speafcations antl any suspension or abandonment has noi exceedetl one (1) year. If changes are made or if suspension or ahantlonment exceeds one (1) year, full fees shall be paitl for a new pertnit. (4) Nb work of any manner shall 6e tlone that will change the naNrel flow of water causing a tlrainage problem. (5) Contrashall notiy the Building Inspector lwenry-four (24) hours in advance tor all inspections and shall receive written approval on inspection cartl before prounce wilh successive phases of the job. (6) Th of a ertnit or the approval of drawings antl specifcations shall not be consiruetl to be a permit for, nor an approval of, any violation of the pmvisions obh~g cos or any other ortlinance, law, rule or regulation. q 7c( Phone : 9q0-3Z6 7 Phone : A//j¢ Construction Value : Permit Fee : Use Tax: Total : tief-Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION OUCHSTONE IMPROVEMENT LOCA'T'ION CERTIFICATE URVEY CO. 97.5 5.0 UTILITY EASE. k x x x x x x ~c ~c ~c ~ C-1CI STING G' Fences - K sxs 11525 W. 38TH. AVE. Shed WHEAT RIDGE, CCLCI WOOD DECK 1 K 12.6' (b m 7 K - 4.7 _ L 2 5' . 13.2' L....:. 1 STORY x M SCALE1 20 I::;::::::;.; F N FRA 152 5 I 7- rn 12d 48.0 30.5' T ~ c9ooo = 4' r-ence S, 1l *-30.0 127 SW COR. SEC 21 T35 R59W FOUND X CAP IN RANGE BOX v-.-.-.-•y ~o o v o cn n o w m o 0 I' .-1 GS Q7,5' NOTE: LOT DIW£NSIONS W. 38TH. AVE. GO' R.O.W. FROM PLAT CN FILE AT JEFFERSON COUNTY CLERK AND RECORDER Zon1E C 2- I herby certify that this improvement location certificate was prepared for 11RSTFEO~Yl4c 1319rJK , that it is not a land survey plat or improvement survey plat, and that it is not to be relied upon for the establishment of fence, building, or other future improvement lines. I further certify that the improvements on the above described parcel on this date -25-9 except utility connections, are entirely within the boundaries o the parcel, except as shown,.that there are no encroachments upon the described premises by improvements on any adjoining premises, except as indicated, and that there is no apparent evidence or sign of any easement crossing or burdening any part of said Parcel, except as noted. TOUCHSTONE SURVEY COMPANY 9590 W. 14th. Ave LAKEWOOD, MLORADO 233-£14313 Property not in flood plane per: C x K PKS~~~ i.-PaF~ ~1 C~- k,= 36 " ->1 L 2y /`e S S ri i/ r-, X,Fr X 4x ~?x z qx 8x V~ « /~e~~'~ ~n _ ; 5-- DEPARTMENT OF COMMUNITY DEVELOPMENT 7500 WEST 29th AVENUE BUILDING INSPECTION DIVISION PERMIT NO. M94#19420 234.5933 P.O. BOX 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED BELOW. APPLICATION FOR MISCELLANEOUS PERMIT JOB ADDRESS 11525 ur. 3g OWNER R,tf /11- ~e CONTRACTOR - 4617 e ADDRESS 525-VJ_ 3,ffi4 ADDRESS PHONE c/8~620y ZIPCODE ~~U33 CITY ZIP CODE PRICE PHONE LICENSE NO. DATE -)Q Z-- I. TYPE Ground❑ Woll❑. Proiecting❑ Other Sor D Face 2. MATERIAL Total Square Feet SIGNS 3. ILLUMINATION Yes❑ No [D Type Elect. Permit No. 4, SET BACK FROM PROPERTY LINE N S_ E_ W Zone_ Approved,Zone Inspector (Specify which is front) ❑ ❑ ❑ ❑ Disapproved 1. TYPE Solid[] More Than 80% Open❑ Lees Than BO% Open FENCES MATERIAL - Height 3. SET BACK FROM PROPERTY LINE N_ S_ E_ W Zone- Apprwed,Zone Inspector (Specify which is front) ❑ ❑ ❑ ❑ Disapproved I. Re-node.e bat oag~ vns OJJ dO ao/z/ d.x~iresy ox./Jany OTHER 2 ~~w2s~/a/ce in~a zcoinii a closet. _ 0~ - INSPECTION TICKET 5 DRAW SKETCH OR SHOW BELOW, THE FENCE, SIGN, OR OTHER STRUCTURE, GIVING DI (SETBACKS OR PROJECTIONS INCLUDED) ADDRESS(/ O REAR PROPERTY LINE JOB DATE: 3-/6 BLDG. PERMIT#.U rte(` PERMIT# BLDG. CONTR. SUBCONTRACTOR FRONT PROPERTY LINE DATE INSP. REQ. STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TO- ADJOINING HOUSES, STREETS, AND PRI TYPE OF INSP. ov DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; N INSPECTION MADE THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY U REMARKS PERMIT WILL EXPIRE 180 DAYS FROM THE DATE OF ISSUANCE IF WOR ELECTRICAL PERMIT STATE LICENSE N0. PLUMBING PERMIT STATE LICENSE NO. ALUM INUM WIRE UNDERSIZE 8ILLEGAL FLOOR BSM IST 2ND 31 N0, WATER CLO ( ✓ W.R. FORM 6-19 TEMPORARY METER WASH BOWL NEW SERVICE - AMPS BATH TUB-, CHANGE SERVICE-AMPS H ✓ LIGHTING - IY\ btu+(, Q f(~/c~.o ✓ J ✓ HEATING -trl ba+1~ 5I-,Etfcg GARBAGE DISP REFRIGERATION SYSTEM POWER SUB-CIRCUITS WATER HEATER Refri Brant Group ✓ UTILITY (RANGE, DISPOSER, ETC.)-k.I-k AUTO. WASHER Pounds Charge FIXTURES DISH WASHER ✓ AUTOMATIC SPRINKLER SYSTEM WIRING MOTORS B CONTROLS FLOOR DRAIN ELEVATOR SIGNS URINAL TRANSFORMERS B RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER HP TOTAL FIXTURES acknowledge that this applica- I h eb PERMIT FEE °J r may. v-~ er y Lion is correct and understand that I USE TAX li- til this d t t thi pp un s projec cannot star cation is approved. I shall comply with TOTAL FEE j Is d t d o an o the laws of the State of Colora the Zoning Regulations and Building Code of the City of Wheat Ridge. Any violation of the above terms will cause - PROVED DISA CHIEF BUILDIN _ INSPECTOR,City of VVVeot Ridge immediate revocation of this permit Date Issued Aettktnts Sienetvre NOT VALID UNLESS RECEIPTED MM CALL 2345933 24 HOURS IN ADVANCE FOR INSPECTIONS `i / OF COMMUNITY 7500 WEST 29th AVENUE DEPARTMENT BUILDING INSPECTION DIVIS ON DEVELOPMENT PERMIT NO. M l' li,~ alQtD 237-6944 EXT. 255 P.O. BOX 639 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED BELOW. =FOR MISC /f P °C ELLANEOUS PEER'~,J, T OWNER , JOB ADDRESS / T :ONTRACTOR ADDRESS ~zS~ ADDRESS ZIP CODE PHONE ~ CITY ZIP CODE PHONE LICENSE NO / ~Z2 ~j CONTRACT PR E $ DATE . TYPE Ground❑ Wall❑ Proiecting❑ Other SorD Face 1 SIGNS . 2. MATERIAL Total Square Feet Permit No e Elect 3 ❑ T ILLUMINATION Y N . . yp . o es 4 SET BACK FROM PROPERTY LINE N_ S_ E_ W Zone_ Apprwed,Zone Inspector (Specify which is front) ❑ ❑ ❑ ❑ Disapproved I. TYPE Solid❑ More Than 80% Open❑ Less Than 80% Open MATERIAL Height FENCES 3. SET BACK FROM PROPERTY LINE N_ S_ E_ W Zone_ Apprwed,Zons Inspector (Specify which is front) ❑ ❑ ❑ ❑ Disapproved I l77 lJ , 2 OTHER . 3 . DRAW SKETCH OR SHOW BELOW, THE FENCE, SIGN, OR OTHER STRUCTURE, GIVING DISTANCES FROM PROPERTY LINES. (SETBACKS OR PROJECTIONS INCLUDED) SPECIFY NORTH STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TO ADJOINING HOUSES, STREETS, AND PROPERTY LINES; ON IRREGULAR LOTS, SHOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMITTO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 180 DAYS FROM THE DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN THAT TIME. ELECTRICAL PERMIT STATE LICENSE NO. PLUMBING PERMIT STATE LICENSE N0. MECHANICAL PERMIT ALUMINUM WIRE UNDER SIZE 8 ILLEGAL NO. TEMPORARY METER FLOOR WATER CLOSET WASH BOWL BSM IST 2ND 3RD 4TH NO. FUEL:Circle One cos ql Propane Cool Elee Solar FORCED AIR - BTU HOT WATER - BTU NEW SERVICE - AMPS CHANGE SERVICE-AMPS BATH TUB SHOWER STEAM - BTU AIR CONDITIONING-BTU LIGHTING SINK OTHER HEATING GARBAGE DISP REFRIGERATION SYSTEM POWER SUB-CIRCUITS WATER HEATER Refrigerant Group UTILITY(RANGE, DISPOSER,ETC) AUTO.WASHER Pounds Charge FIXTURES DISH WASHER AUTOMATIC SPRINKLER SYSTEM WIRING MOTORS a CONTROLS FLOOR DRAIN ELEVATOR SIGNS URINAL TRANSFORMERS B RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES REMARKS I hereby acknowledge that this applica- tion is correct and understand that I cannot start this project until this CPO- cation is approved. I shall comply with the laws of the State of Colorado and to the Zoning Regulations and Building Code of the City of Wheat Ridge. Any violation of the above terms will cause im dia revocation of this permit APPUCOMS S1000- PERMIT FEE USE TAX TOTAL FEE CHIEF BU ,City of Wheat Ridge Date Issued_~ NOT VALID UNLESS RECEIPTED 368Z CALL 237-6944 EXT. 255 24 HOURS IN ADVANCE FOR INSPECTIONS