Loading...
HomeMy WebLinkAbout9240 W 49th Avenue1* � � i City of Wheat Ridge �� Resid. Windows/Doors PERMIT - 202101154 PERMIT NO: 202101154 ISSUED: 06/01/2021 JOB ADDRESS: 9240 W 49th Ave 304 EXPIRES: 06/01/2022 JOB DESCRIPTION: Replace (1) patio door .29 u -factor *** CONTACTS *** OWNER (72 0) 933-6714 POND CHRISTOPHER S SUB (971)803-7151 RICHARD SMOTHERS 210044 PREMIER SERVICES GROUP *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2936 / SHARON MANOR / WESTPARK BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 31143.06 FEES Window Replacement 50.00 Total Valuation 0.00 Use Tax 66.00 ** TOTAL ** 116.00 *** COMMENTS *** *** CONDITIONS *** Windows shall comply with all applicable codes, have a .30 or better U -factor and shall be safety glazing if within a tub enclosure, less than 18 inches above the floor or within 24 inches of a vertical edge of a door. I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications, applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/01/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. N�:llil� • THERM AITRU® Benchmark: Doors 6 -PANEL - SMOOTH SURFACE Pre -hung Single Entry Door MATERIAL: Fiberglass Smooth GLASS: None FINISH: Unfinished I• JAMB: 4 -9/16 -In Primed Pine BORE: Double Bore DOOR THICKNESS: 1 -3/4 -in BRICKMOLD: Primed THRESHOLD: Adjustable - Mill Finish DP RATING:Li 0 NOMINAL DIMENSIONS 36 -in x 80 -in ACTUAL DIMENSIONS 37 -1/2 -in x 81 -1/2 -in EXTERIOR VIEW Right Hand FITS ROUGH OPENING 38 -1/4 -in x 82 -in BMTT # BMTTSFG1130RBM --- COWES MODEL # BMTTSFG1130RBM 228473'IPIII'lll`'IIIhI!Ili QTY - 1 6 -ft Le�el 2 -ft Levet •Square •Hammer • Tape Measure •Staple Gun • Power Drill with 1J8 -In Wood Drift Bit • Phillips Mead Screwdriver • N2 and 443 Phillips Drill Bit • Safety Glasses • Safety Gloves HERRAMIENTAS NECESARIAS PARA UNA INSTAI er Viw. r.,nn. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Window/Door Replacement Permit Application Date: Tuesday, June 1, 20213:12:45 PM Residential Window/Door Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WINDOWS and DOORS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM AND WINDOW/DOOR CUTSHEET (SPEC SHEET) IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes replacement window(s) and/or door(s) like for like? PROPERTY INFORMATION Property Address 9240 W 49TH AVE #304 Property Owner Name Janice fisher Property Owner Phone 7208387445 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email permitting@premierservicegrp.com Address Attach City of Wheat Wheat ridae cc form Ddf Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTRACTOR INFORMATION Contractor Business NW Extreme Installers, Inc. Name Contractor's License 2020151727 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) Contractor Email Address Retype Contractor Email Address DESCRIPTION OF WORK What is being replaced Number of window and/or doors being replaced 1.119UNIIIIN-PAN permitting@premierservicegrp.com permitting@premierservicegrp.com Doors Location of patio window(s)/door(s) being replaced (for example, master bedroom, kitchen, bathroom, etc): What is the u -value of .29 the window(s)/door(s)? City of Wheat Ridge requires the u -value to be .30 or better on windows.. Attach copy of fishersoecs2.odf window/door cut sheets showing sizes and u - value Project Value (contract 3143.06 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Brook Leslie Permit Email not displaying correctly? View it in your browser. i ISI-N10F WHEAT, RIDGE Building Inspection`DIvision (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: I,;? Permit Number: __2E? I cj (P ❑ No one available for inspection: Time 1 '.ANJ%PM Re -Inspection required: Ye �`No---' When corrections have been madeschedule for re -inspection online at. http✓/www.ci. wheatridge.co.uslinspection Date:-/,.--'-':). r -Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge E -Res. Window Replacement PERMIT - 201901889 PERMIT NO: 201901889 ISSUED: 09/06/2019 JOB ADDRESS: 9240 W 49th Ave 311 EXPIRES: 09/05/2020 JOB DESCRIPTION: Replacing 3 windows throughout house. U -factor .32 *** CONTACTS *** OWNER (719)362-6922 VILLANUEVA VANESSA SUB (770)433-8211 GARY CUMMINGS 170102 HOME DEPOT U.S.A., INC. M *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2936 / SHARON MANOR / WESTPARK BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 3,393.00 FEES Window Replacement 50.00 Total Valuation 0.00 Use Tax 71.25 ** TOTAL ** 121.25 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications= applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authonzed by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be erormeisdiscI osed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Budding Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any apphcaE1e code or any rdinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chilf Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dina Kemp 90, � 9 q From: no-reply@ci.wheatridge.co.us Sent: Thursday, September 5, 2019 7:58 PM To: CommDev Permits Subject: Online Form Submittal: Residential Window/Door Replacement Permit Application Residential Window/Door Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WINDOWS and DOORS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM AND WINDOW/DOOR CUTSHEET (SPEC SHEET) IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes replacement window(s) and/or door(s) like for like? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address **REQUIRED** Attach Credit Card Authorization Form - **DO NOT ATTACH RANDOM DOCUMENTS 9240 W 49th Ave, #311 Vanessa Villanueva 719-362-6922 Field not completed. Villanueva cc form - 10921243.pdf CONTRACTOR INFORMATION Contractor Business HOME DEPOT U.S.A., INC. Name Contractor's License 170102 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 801-710-2507 Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address jamie@reedysetgo.com Retype Contractor Email jamie@reedysetgo.com Address DESCRIPTION OF WORK Number of window 3 and/or doors being replaced Location of 2 bedrooms, 1 kitchen window(s)/door(s) being replaced (for example, master bedroom, kitchen, bathroom, etc): What is the a -value of the .32 window(s)/door(s)? City of Wheat Ridge requires the u -value to be .32 or better on windows.. Attach copy of Villanueva specs - 10921243.pdf window/door cut sheets showing sizes and a -value Project Value (contract 3393 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit 01 issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Jamie Reed Permit Email not displaying correctly? View it in your browser. City of Wheat Ridge f. E -Res. Window Replacement PERMIT - 201803121 PERMIT NO: 201803121 ISSUED: 12/03/2018 JOB ADDRESS: 9240 W 49th Ave 304 EXPIRES: 12/03/2019 JOB DESCRIPTION: Residential windows replacing 3 windows and a patio door, like for like. U -factor is 0.28. *** CONTACTS *** OWNER (720)933-6714 POND CHRISTOPHER S SUB (303)421-7100 Ted Roland 018516 K&H Windows & Exteriors *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2936 / SHARON MANOR / WESTPARK BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,362.00 FEES Window Replacement 50.00 Total Valuation 0.00 Use Tax 91.60 ** TOTAL ** 141.60 *** COMMENTS *** *** CONDITIONS *** Windows shall comply with all applicable codes, have a .32 or better U -factor and shall be safety glazing if within a tub enclosure, less than 18 inches above the floor or within 24 inches of a vertical edge of a door. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that i am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I am legally authorized to include all entities named within this document as partes to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1_ This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements; fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. T i ance or gra i g of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any a ' ble ode or ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dina Kemp 'l �L From: no-reply@ci.wheatridge.co.us Sent: Monday, December 3, 2018 8:31 AM To: CommDev Permits Subject: Online Form Submittal: Residential Window/Door Replacement Permit Application Categories: Dina Residential Window/Door Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WINDOWS and DOORS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM AND WINDOW/DOOR CUTSHEET (SPEC SHEET) IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes replacement window(s) and/or door(s) like for like? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address Attach Credit Card Authorization Form - **DO NOT ATTACH RANDOM DOCUMENTS** 9240 West 49th Ave #304 Wheat Ridge, CO 80033 �-z Christopher Pond (720)933-6714 Field not completed. Pond cc form.gdf CONTRACTOR INFORMATION I Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) K&H Windows and Exteriors 018516 720-420-1724 5805 w 56th ave Arvada co, 80002 Contractor Email Address sgeorge@khwindows.com Retype Contractor Email sgeorge@khwindows.com Address DESCRIPTION OF WORK Number of window Replace 3 windows and a patio door with vinyl soft -lite and and/or doors being sunrise windows. Like for like. replaced Location of living room, Kitchen, Bedroom and Master bedroom. window(s)/door(s) being replaced (for example, master bedroom, kitchen, bathroom, etc): What is the u -value of the 0.28 window(s)/door(s)? City of Wheat Ridge requires the a -value to be .32 or better on windows.. Attach copy of pond measure.pdf window/door cut sheets showing sizes and u -value Project Value (contract 4362 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for z compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Shawn George Permit Email not displaying correctly? View it in your browser. e i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 43-e� f 49 J1 - Job Address: q 2 40 Ulf 49 V4 11V t Permit Number: 20[S-62242-7 ❑ No one available for inspection;. Time 1 AM/PM Re -Inspection required: Yes :' No _ r When corrections have been made, call for re -inspection at 303-234-5933 Date: 1 Inspector: DO NOT REMOVE THIS NOTICE A ® City of Wheat Ridge Commercial Plumbing PERMIT - 201802427 PERMIT NO: 201802427 ISSUED: 09/04/2018 JOB ADDRESS: 9240 W 49th Ave EXPIRES: 09/04/2019 JOB DESCRIPTION: 10 ft Sewerline clean out repair for whole condo building at 9240 W 49th Ave, installing dual clean outs. In yard repair. *** CONTACTS *** (720)377-0100 (303)210-8207 CON SUB OWNER Jack Brandon Weston Gary Galger CMS 110115 Premier Excavation Services *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2936 / SHARON MANOR / WESTPARK BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 1,700.00 FEES Total Valuation 0.00 Use Tax 35.70 Permit Fee 67.30 ** TOTAL ** 103.00 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** City of Wheat Ridge V, Commercial Plumbing PERMIT - 201802427 PERMIT NO: 201802427 ISSUED: 09/04/2018 JOB ADDRESS: 9240 W 49th Ave EXPIRES: 09/04/2019 JOB DESCRIPTION: 10 ft Sewerline clean out repair for whole condo building at 9240 W 49th Ave, installing dual clean outs. In yard repair. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further atte that I am legally authorized to include all entities named within this document as parties to the work to be performed and that a wok to be performed 's disclosed in t4is.document and/or its' accompanying approved plans and specifications. Signature of OWN or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original ermrt fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Off Bial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services 6. The issuance or granting of ermit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable e or any ordi ce or regulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of Chief But ding Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat jdge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(a)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Property Owner (please print): C Yy) -S Property Owner Email: I C,. k- & 3y (B vg - S -+71 Tenant (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: 9 240 W w 1 A 0" Citv, State Architect/Engineer E-mail: Phone: Contractor Name: VI(e YhtF f &Coa iat-t Ove City of Wheat Ridge License #: I I - 61 - ) '�__ Contractor E-mail Address: +1 ohoneC�?Z 3) Phone: (3c)3) Z l0 - q -fqT- C For Plan Review Questions & Comments (please print): CONTACT NAME (please print): c()bJ We'Skbyx Phonet3c'3)Z[0'q 1 q'(- CONTACT EMAIL(p/ease print): Sub Contractors (Must provide Wheat Ridge License No.): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # ® COMMERCIAL ❑ RESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. 5 "" l Va., y SQ W(f 11, nve ,it fu I r I V1 go /� o V1< <% ctbo � � 10, � 1 v1Sl-ci I 1i o, 6 va J 5� w C`L q(� 0 6. Y Sq. FULF Amps BTUs Squares Gallons Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Project V'a]l_u_en(Contract value or the cost of all materials and labor included in the entire project) $ 11 Uo OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record. that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that ytity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on th , application. CIRCLE ONE: (OWNER) Signature (first and last name):, Printed Name: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: or (AUTHORIZED REPRESENTATIVE) of (OWNS ACTOR) DATE: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: A " I'll City of Date: Wh6atl 1d ie COMMUNiTy DEW LOPMENT Plawpermit # Building & Inspection Services Division 7500 W. 2e Ave., Wheat Ridge, CO 80033 Plan Review Fee: Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line; 303-234-5933 Email: pq[MjLsi.leatrid e.cs.us Building Permit Application Property Address: 9 ? LICj Property Owner (p(ease prim L). (":(tucle" Phone: Property Owner Email: Mailing Address: (if different than property address) Address: City, State, Zip: AmbibWAnalmr; ArchitecttEriginear E-mail: Phone,*..,. Contractor: cvt, C�2� fr' C c6in')r"� Contractors City License Phone: Contractor E-mail Address. Sub Contractors: Electrical: Plumbing: Mechanical: W.R. City License # W.R City License# W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form 0 COMMERCIAL lrpr.. y STRUCTURE tMr y dry # UPGRADE +IR d #. NEW RESIDENTIAL STRUCTURE COMMERCIAL RFING COMMERCIAL ADDITION RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT COMMERCIAL t A.ar STRUCTURE r . ..•..a.. shed, deck, + RESIDENTIAL ACCESSORY STRUCTURE r s yr ® shed, deck, MECHANICAL d #tMd REPAIR • ♦r. REPLACEMENT M M d PLUMBING SYSTEIVI/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPT or REPLACEMENT OTHER b* riaterlats is beused, etc. `' < " . ("C l y `U-"" Sq. FULF Btu's Gallons City of Ni 91 Ri COMMUNITY DEVELOPPLJENT'� Building Inspecdon Services Division FOR OFFICE USE ONLY 4141, Dater _Plan Review Fee: .°. Office: 303-235-2885 * Fax: 303-237-8929 Inspection kine; 303-2:34-8933 4 Building Permit Application PAID Please complete all highlighted areas on both skies of this form. incomplete bppll"t uts rt gr nc�t lad r sed. (please print): /Al- WoUrl Mailing Address: (if different than property address) Address: City, State, Zip: rch tect/ rr fine r E-mail.- Phone: .� z z M Contractor: Contractors City License � 2� "hone:., •. ContractorE-mail Address: "/ Electrical: Plumbing: Mechanical: W.R. City License # WR City License # W,R. City License Other City Licensed Serb: Other City Licensed Sub. City License # City License Complete all information on BOTH sides of t lot � 4 A i♦ p • • f r � w p a ♦ ,,. tit of materials to be used, etc ,S.A,cu-(- 0-,V\,8 �)c�CA-, fkc,1?IC(,CC,/P?cJ- , FULF Btu's Gallons Ps Squares Other City of ]R"Wh6atRoge CITY of WHEAT RIDGE BUILDING AND INSPECTION SERVICES DIVISION 7500 W 29th Ave Wheat Ridge, CO 80033-8001 p. 303,235,2855,f 313.237,$924 iq� 11111111►MW ► 11111111 iiiii,., r r . copy of this form must be completed by each agency indicated on the Permit Submittal Checklist for the project type and be attached to the wilding Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required ardency will not be accepted or processed.. Gate: tA Project Address. mq./ ,. . ... '' i �a Fume of Firm/Individual surmmtting documents: Project hype/Description. f. "' <° 21 I,CAC-�1-112 am a duly authorized representative of the agency indicated below and do, by mysiga atiar below, hereby acknowledge receipt of documents necessary for review and approval of the' reject indicated above. ° (Please deck one) o Wheat Ridge Fire Protection rvada Fire Protection o Wheat Ridge Sanitation District o Clear Creek Sanitation District o Wheat Ridge Water District o Fruitdale Sanitation District o Consolidated Mutual Water District o Westridge Sanitation District 0 Valley Water District o Denver Water o Other Agency dotes: o / e 4 a, f,). r , ILI ,. Signature. Date: (Agency Representative) MOZER-RENN MozER-RENN STRUCTURAL SERVICE, INC. 6000 E. EVANs AVE, BLDG. 1, STE. 021 DENVER, CO 90222 Phone, 303-159-2200 ax. 303-484-8958 STRUCTURAL SERVIMINC, Ms. Sherryn Hensley, Code Consultants International c/o City of Wheat Ridge Building and Inspection Services Denver 7500 W. 29th Ave., 2nd Floor Wheat Ridge, CO 80033 RE: Response to Plan Review Comments for 9240, 9340 & 9380 W. 4911, Ave. Deck & Replacement (Le Marquis Condominiums) Review Reference No. 201600270, MR Job #0802CI6 As structural Engineer of Record for the exterior deck and stairwell replacements at 9240, 9340 & 9380 W. 49th Ave. in Wheat Ridge (the Le Marquis Condominiums), the following responses are submitted to address the March 4, 2016 Building Code Analysis received from Code Consultants International regarding the project. Items listed in the plan review are provided below for reference, with written responses given below in bold font. S-1 A wind load of 105 mph, Exposure C is required. Correct this note in the plans or provide a stamped engineer's letter. Structural design for the deck and stairwell was re -visited, and due to the all projected areas of each of these structures the increase to Exposure C does not significantly increase size of members or their connections. B-1 Balusters are not to allow, the passage of a 4" rhauncters-phere. Typical handrail detail on Sheet ALO shows 13/81' square balusters at 5 1/4". As discussed on during our phone conversation, field adjustment to assure no passage of a 411 diameter sphere will be addressed by the Contractor. Please contact Mozer-Renn Structural Service, Inc. w! any turtner que structural engineering design. MOZER-RENN a EhIbUl"M SERVICE, INC—, nmozeiurenn@MRstructural.com www.MRstructuraLconn m m I N T E R N X° 1# 2* L 3190 S Wadsworth Blvd., Suite 220, Lakewood, CO 80227 303,973.7766 %x30&973.77&6 www.buildingcci.com .roject. 924093409380 W. 49th Ave. *201600270 F 2012 International Building Code 2012 International Plumbing Code atkram�-F-we-rg,kLC-nn -rvation Code 2014 National Electrical Code w"U"A FTMWif sMWWVW P&MAVAM&I F. M, Standards listed above. RNB�� Code Consultants Intematlonal - Copyright 20,15, City of Wheat Ridge, 9240,9340,9380 W 49th Avenue Page 2 of 8 Code Consultants interruhronal , Copyright 2015, CIP, of Wheat Ridge, 9240,9340,9380 W 49th Avenue Page 3 of 8 L� F MMEE= Code Consultants International - Co tight 20M City of Wheat Ridge, 9240,9340,9380 W 49th Avenue Page 4 of 8 1*1sr4w-. WIWK4 sammmmm PROPOSED AREA: Exisbng, no change CWe Consultants Intemadonal - Copyright 2015, City of Wheat Ridge. 9240,9340.9380 W 49th Avenue Page 5 of 8 This section does not apply, The project is forthe replacement of exterior steps. No information regarding the interior of the building is provided. Carle Consultants Inteinationid � Copyright 2015, City of Wheat Ridge, 9240,9340,9380 VV 49th Avenoe, Page 6 of 8 2,41 iii�liiiNI Item ; Sheet A wind load of 305 mph, Exposure C is required, Correct this note on the plans or 5.3 Cover provide a stamped engineer's letter. Code Consultants tnterae Oonai • Ctttty6gM 2015, City of What Rkdge, 92 #0,9340.93850 W 49th Avenue mage 7 of 8 BUILDING COMMENTS Item Sheet B-1 A-9 Balusters are not to allow the passage of a 4" diameter sphere. Cade Consultants International, Cnpy fight 2015, City at WIx at Ridge, 9,140,9340,9380 W 49th Avenue Page 8 of 8 GENERAL ARCHITECTURAL NOTES -EXTERIOR STAIRWAYS IN GROUP R-2 OCCUPANCY STAIRWAYS SHALL HAVE A WIDTH OF NOT LESS THAN 36" (OCCUPANT LOAD LESS THAN 50). THIS SHALL BE MEASURED FROM FACE OF HANDRAIL TO HANDRAIL. HEADROOM: STAIRWAYS SHALL HAVE A MINIMUM HEADROOM CLEARANCE OF 80" MEASURED VERTICALLY FROM A LINE CONNECTING THE EDGE OF THE NOSINGS. SUCH HEADROOM SHALL BE CONTINUOUS ABOVE THE STAIRWAY TO THE POINT WHERE THE LINE INTERSECTS THE LANDING BELOW, ONE TREAD DEPTH BEYOND THE BOTTOM RISER. THE MINIMUM CLEARANCE SHALL BE MAINTAINED THE FULL WIDTH OF THE STAIRWAY AND LANDING. STAIR RISER HEIGHTS SHALL BE 7" MAXIMUM AND 4" MINIMUM. STAIR TREAD DEPTHS SHALL BE 11" MINIMUM. THE RISER HEIGHT SHALL BE I MEASURED VERTICALLY BETWEEN THE LEADING EDGES OF ADJACENT TREADS. STAIR TREADS AND RISERS SHALL BE OF UNIFORM SIZE AND SHAPE, THE TOLERANCE BETWEEN THE LARGEST AND SMALLEST RISER HEIGHT OR BETWEEN THE LARGEST AND SMALLEST TREAD DEPTH SHALL NOT EXCEED 0.375" IN ANY FLIGHT OF STAIRS. WHERE THE BOTTOM OR TOP RISER ADJOINS A SLOPING PUBLIC WAY, WALKWAY OR DRIVEWAY HAVING AN ESTABLISHED GRADE AND SERVING AS A LANDING, THE BOTTOM OR TOP RISER IS PERMITTED TO BE REDUCED ALONG THE SLOPE TO LESS THAN 4" IN HEIGHT, WITH THE VARIATION IN HEIGHT OF THE BOTTOM OR TOP RISER NOT TO EXCEED ONE UNIT VERTICAL IN 12 UNITS HORIZONTAL OF STAIRWAY WIDTH. THE NOSINGS OR LEADING EDGES OF TREAD AT SUCH NON-UNIFORM HEIGHT RISERS SHALL HAVE A DISTINCTNE MARKING STRIPE, DIFFERENT FROM ANY OTHER NOSING MARKING PROVIDED ON THE STAIR FLIGHT. THE DISTINCTIVE MARKING STRIPE SHALL BE VISIBLE IN DESCENT OF THE STAIR AND SHALL HAVE ASLIP-RESISTANT SURFACE. MARKING STRIPES SHALL HAVE A WIDTH OF AT LEAST 1" BUT NOT MORE THAN 2". THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE NOT GREATER THAN 0.5" AND BEVELING OF NOSING SHALL NOT EXCEED 0.5". THE NOSINGS OF TREAD SHALL PROJECT NO MORE THAN 1.25" BEYOND THE TREAD BELOW AND ALL PROJECTIONS OF THE LEADING EDGES SHALL BE OF UNIFORM SIZE, INCLUDING THE LEADING EDGE OF THE FLOOR AT THE TOP OF A FLIGHT. THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM OF EACH STAIRWAY. THE WIDTH OF LANDINGS SHALL NOT BE LESS THAN THE WIDTH OF STAIRWAYS THEY SERVE. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION MEASURED IN THE DIRECTION OF TRAVEL EQUAL TO THE WIDTH OF THE STAIRWAY. THE STAIRWAY WALKING SURFACE OF TREADS AND LANDINGS SHALL NOT BE SLOPED STEEPER THAN ONE UNIT VERTICAL IN 48 UNITS HORIZONTAL (2% SLOPE) IN ANY DIRECTION. STAIRWAY TREADS AND LANDINGS SHALL HAVE A SOLID SURFACE, OUTDOOR STAIRWAYS AND OUTDOOR APPROACHES TO STAIRWAYS SHALL BE dESIGNED SO THAT WATER WILL NOT ACCUMULATE ON WALKING SURFACES. STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE (EXCEPT WHERE HANDRAILS ON BOTH SIDES WOULD PREVENT 36" WIDTH CLEARANCE) ANS SHALL BE AT A HEIGHT MEASURED ABOVE STAIR TREAD NOSINGS OF NOT LESS THAN 34" AND NOT MORE THAN 38". HANDRAILS WITH A CIRCULAR CROSS-SECTION SHALL HAVE AN OUTSIDE DIAMETER OF AT LEAST 1.25" AND NOT GREATER THAN 2" OR EQUIVALENT. IF THE HANDRAIL IS NOT CIRCULAR, IT SHALL HAVE A PERIMETER DIMENSION OF AT LEAST 4" AND NOT GREATER THAN 6.25` WITH A MAXIMUM CROSS-SECTION DIMENSION OF 2.25" EDGES SHALL HAVE A MINIMUM RADIUS OF 0.01" HANDRAIL GRIPPING SURFACES SHALL BE CONTINUOUS, WITHOUT INTERRUPTION BY NEWEL POSTS OR OTHER OBSTRUCTIONS. 4x4 POSTS @ 6' MAX. TREX GUARDRAIL RE: DETAIL 2/A1.0 -- AND SECTION 1/S1.0 HANDRAIL EXTENSION L tV M CD tV NEW CONCRETE SIDEWALK WHERE NEEDED & FEASIBLE h HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT OR RAMP RUN. AT ji, C:Dl: HANDRAILS ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE k AYS WHIlxt. HANDRAIL$ , EXTEND HORIZONTALLY . LEAST BEYOND i• RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. rriI DE CLEAR SPACEOF A HANDRAIL AND ♦ WALL OF OTHER SURFACE. GUARDS BE LOCATED ALONG OPEN -SIDED WALKING SURFACES, PLATFORMS, STAIRWAYS, RAMPS, rLANDINGS THAT ARE ! r r MORE 30" :i !i" OR GRADE BELOW. •'rS SHALL FOR PROTECTIVE PASS.BARRIER NOT LESS THAN 42" HIGH, MEASURED VERTICALLY ABOVE THE LEADING EDGE OF THE TREAD OR ADJACENT WALKING SURFACE, OPEN GUARDS SHALL HAVE BALUSTERS OR ORNAMENTAL PATTERNS SUCH THAT A 4" DIAMETER SPHERE CANNOT PASS THROUGH ANY OPENING UP TO A HEIGHT OF 34". FROM A HEIGHT OF 34" TO 42" ABOVE THE ADJACENT WALKING SURFACES, A SPHERE 8" IN DIAMETER SHALL NOT TRIANGULAR A♦r !' it r BY THE RISER, P a i AND BOTTOM RAIL AT OPEN r OF ♦ STAIRWAY SHALLOF . MAXIMUM SPHERE OF 6" IN DIAMETER CANNOT PASS THROUGH THE OPENING. 11" INLn. cn 100 2 X 6 TREX CONTINUOUS STRINGER, RE: STRUCT'L CONCRETE PIERS, RE: STRUCT'L 1 TYPICAL STAIR DETAIL 1.0 1/211=11.011 HANDRAIL, 1-3/811-1-1/2" ROUND OR RECT., MAX. 6.25" PERIMETER DIM. 1-3/8 X 1-3/8 BALUSTERS @ 5-3/8" Q.C. 4 X 4 POST @ 6' OC RE STRUC C1C \U- � 0 ly8�� a W 0 Go M M HANDRAIL DETAIL u z d Z c� 0 o W CC 0 E— z 0 ce. W �c . ri i rrir r •rir i i �r � i r !'r 1 ;, r, r ! ' " r ♦r r i •, it rrir r ! ♦ rri r rrir r i" ` i :'♦ ! 1 " • i i ! , , i • ! r i ! a ! • i • r i r , r !•i ` •'i' ! i 1 it ! `` !� r i• i r i' ! i 1 i ' : r a r r r : i ' r ♦ ♦ •rri•• rr it i r i !10 ! : ` '` i ' r! ! ♦ r r ♦ a rri r ' ! i i ! rr ! r ♦ err ! i•♦ ,• • i• i r a i• r •. ! ! ! r � r r • r i ! ' i s ! r� r rir r i i A r rrr r ! r: r ' ` i '• ! ! r ri ri r i t r r i r r r•' !" 1 ! r r,r �. i t r DO ! r i it i ... .; •! ! ! ` ! i ! i i r !, rr r ♦ r r .,� � . . .� ! "'r ♦ � r•a r ri r , r ® ♦ r ri i !! !! ♦ r i ` r i r i ! r i r !. . • . ' r r .1 ' i i r ' ♦ !" ! `' : ! i ♦ ! • .! r • it a �, r �• r i ♦ i r♦ r r r r � , i a r♦ r r ! r• r ` i ` ! ': r' ♦ � r • r ! • ! r • !• it • r r ♦ .r r i it '`r i ' ! ♦ • ! ! • r • .♦ • r . � . • ! ! ! i' i ! r i ♦ :' ` !' '� r i r • r • i ! • i ♦ � i r r r !• r A r r rr it i ` i i •1 i4W 01 id id Wil N4 LW6 •r • ♦ : r !U 4 r • r . ! r • ! # r r r r . r a r ! r r r r ♦ r• r �� r � ,, r !: i r •• � ! r , !r ri r !• { i t r,• r r r r i i r : r r r r i i f 11;: ; { r�� • • ' * r : '` : ` it r i rri• r ••! i ! r: ! !" ! r i rrir r i! r • ! ! r , r i. i r r a r ♦ i ! i♦rrj ! ! r' ! �" W. 9th Avemue SCALE: 1/32"=1'-0" PLAN NORTH 71 STRUCTURAL SERVICE 6000 E. EVANS AVENUE SUITE #1-021 DENVER, CO 80222 303-759-2200 nmozer-rens@MRstructural.com L RAD' *10 C' •• N • 0802Cl,',J- 0 /a - 2015 ,it-icale: As Notel.-i heet Title: GENERAL NOTES & SITE PLAN heet No. TREATED 2x8 LEDGER AS IN 5/S3 PLUS 2 LEDGERLOK @ 8" C -C AT EDGE BEAMS . 00 HU28-2 HANGER N EA. END, 00011% TYP. TREATED 2x4 @ 12" Q.C. ---' w1 H (EX) 8" CONC. RETAINING WALL AROUND BELOW -GRADE PATIO LANDING FRAMING AS AT 2nd FLR. ANGLES TO EDGE BEAMS r }---- TREATED 2x4 @ 12" O.C. LANDING JOISTS W/ LUS24 EA. END i 2x8 EDGE JOISTS TREATED 2x INTERMEDIATE STRINGERS @ 12 O.C. W/ 2-00 TO EDGE BEAMS SWITC H BAC K STAI RS 2nd FLOOR & LANDING FRAMING PLAN SCALE: 1/4"=1'-0" (EX) EXTERIOR STUD WALLS ON CONC. FOUNDATIONS TREATED 2x8 LEDGER AS AT 2nd FLOOR _(�X) CONC. 0 2 S3 ko Z 2 R+y Cj+RC,ojF`� pO,S. S1 �O00, 'L9 31_11 6'-5y2" MIN. 31_7" STAIR STRINGERS AS NOTED AT 2nd FLR. STAIR FRAMING PLAN 131.7211 MIT, LONGER IF ADD'L. RISER IS REQ'D. HANDRAIL, RE: SHEET Al FASTEN STRINGER BASE TO (EX) CONC. WALL SIM. SEC. 1/S3 (2) #5 x3'-4 DOWELS W/ 5Y" MIN. EMBED IN DRILLED HOLES W/ HILTI HIT 200 OR EQUIVALENT INJECTED ADHESIVE (EX) 8" CONC. RETAINING WALL 811x18" MIN. DEEP CONC. CURB AS IN SEC. 1/S3 1 SECTION PLAN NOTES 1. COORDINATE DIMENSIONS WITH EXISTING CONDITIONS AND MINIMUM SWITCH BACK STAIRS. ARCHITECTURAL DIMENSIONAL REQUIREMENTS. NUMBER OF STAIR RISERS MAY VARY BLED UPON ELEVATION DIFFERENCES. COORDINATE WITH DETAILS ONSHEET Al. 1st FLOOR & FOUNDATION PLAN 2. REFER TO STRUCTURAL GENERAL NOTES ON SHEET Al FOR ADDITIONAL FRAMING AND DESIGN LOAD INFORMATION. SCALE: 1/4"V-011 3 DESIGN AM WITH DISCREPANCIES. CTOR TO FIELD VERIFY TING (EX) CONDITIONS. CONTACT 4. REMOVE AND REPLACE ALL EXTERIOR STAIRWELLS AND DECKS. REPORT ALL DAMAGED (EX) BUILDING STRUCTURE THAT IS NOT BEING REPLACED TO THE ENGINEER. 5. REPLACEMENT DECKING IS TREX (OR APPROVED EQUIVALENT) 2x6 NOMINAL. p 6. PROVIDE TREE (OR APPROVED EQUIVALENT TRADITIONAL RAISINGS AROUND DECK PERIMETERS AND ALONG STAIRWELLS. RE: SHEET Al FOR DIMENSIONRL REQUIREMENTS AND 4/S3 & 6/S3 FOR ATTACHMENT INFORMATION• TREATED 2x8 LEDGER, RE: SEC. 5/S3 ASSUMED (EX) 2x RIMBOARD, F.V.CONDITION TREATED (2) 2x8 W/ L50 TO LEDGER & EDGE BEAM --- �a TREATED 2x4 @ 12" DECK JOISTS W/ LUS4 EACH END 4x4 COL. HANG 3x STRINGER FROM COL. AS SHOWN ABV. ABA44Z COL. BASE W/ l" DIA. x10" HOOKED ANCHOR BOLT CONC. SIDEWALK, REMOVE 8t REPLACE AS NEEDED 89'-0 a~. 0 (2) #5 VERT. W/ 10" TOP HOOKS Com` a� tj 31_ 0 3x10 MIN. TREATED STRINGERS W/ LS70 ANGLES TO EDGE BEAM & RAILING ATTACHED TO IT PER DETAIL 4/S3 TYP. LEDGER TO CONDO, RE: SEC. 5/S3 (2) 2x$ - TREATED DOUBLE 2x8 LEDGERJOUTLOOKER, FASTEN TO (EX) WALL PER SEC. 1/S1 INVERTED HUS28-2 TREATED, NOTCHED 2x INTERMEDIATED STRINGERS @ 12"t W/ 2-00 TO EDGE BEAM _T-.tT_ w MOM A__ 31.37411 1 S3 mawsmuzu= 1 r 004 .ki Lemmilr. IV*] ONEmSTORY STAIR/DECK: FOUNDATION & FRAMING PLAN SCALE: 1/4" V-0" (EX) CONDO FLR. FRAMING & EXTERIOR WALL - �i l r iii i i i BEHINDFLASHING r OVER e 3' SCREWS ASSUMED CONT. tn SHEATHING & SIDING ON EXTERIOR WALL. REMOVE (EX) 6000 cn DOORWAY � DENVER, CO 80222 303-759-2200 no nmozer-renn@MRstructural.com p\..0 RADO UJ r-1 � EN COQ � (CO cn g AAJ LL r r � Z 2 C)m S1 0 S3 moo U Com` a� tj 31_ 0 3x10 MIN. TREATED STRINGERS W/ LS70 ANGLES TO EDGE BEAM & RAILING ATTACHED TO IT PER DETAIL 4/S3 TYP. LEDGER TO CONDO, RE: SEC. 5/S3 (2) 2x$ - TREATED DOUBLE 2x8 LEDGERJOUTLOOKER, FASTEN TO (EX) WALL PER SEC. 1/S1 INVERTED HUS28-2 TREATED, NOTCHED 2x INTERMEDIATED STRINGERS @ 12"t W/ 2-00 TO EDGE BEAM _T-.tT_ w MOM A__ 31.37411 1 S3 mawsmuzu= 1 r 004 .ki Lemmilr. IV*] ONEmSTORY STAIR/DECK: FOUNDATION & FRAMING PLAN SCALE: 1/4" V-0" (EX) CONDO FLR. FRAMING & EXTERIOR WALL - �i l r iii i i i BEHINDFLASHING r OVER e 3' SCREWS ASSUMED CONT. MOZER-RENN SHEATHING & SIDING ON EXTERIOR WALL. REMOVE SIDING AT LEDGERS 6000 FLASHING BEHIND SIDING SUITE #1-021 & OVER LEDGER DENVER, CO 80222 TYPICAL DECKING, RE: PLAN NOTES TREATED 2x4 DECK JOISTS BOTTOM REYOND TREATED (2) 2x8 OUTLOOKER/LEDGER RE: ABV. FOR FASTENING LAYOUT TO (EX) RIMBOARD (EX) FOUNDATION WALL .......,...,` . _�-: r DE •-- ..... ..` /72 SECTION ,***% si 3/411 = 1 1-011 13 MOZER-RENN STRUCTURAL SERVICE 6000 E. EVANS AVENUE SUITE #1-021 DENVER, CO 80222 303-759-2200 nmozer-renn@MRstructural.com p\..0 RADO � EN COQ � (CO � Q C)m 0 00 moo U V) rtl 4=J CD Ntr11*4 C�1 Job-- No: 080X1 5 ate: Nov. 30, 2015 Cale: As Noted heet Title: STAIRWELL FRAMING & FOUNDATION PLANS h eet No. 4 c c r F.V. CONDITION & PRESENCE OF ASSUMED BLKG. BTWN. JOISTS. REPLACE DAMAGED/DETERIORATED LUMBER (EX) EXTERIOR STUD WALLS TWOSTORY DECKS,x Ist & 2nd FLOOR FRAMING PLAN SCALE: 1/4"�V-0" %-. .` - wv. 15v5 . %ice 1 / Sao 'Val 7V IF AROUND BELOW -GRADE PATIO TwOmSTORY DECKS.8 FOUNDATION PLAN SCALE: 1/4". 11.011 (EX; RAILIP EMBEDS SA 1 SECTION 52 i l/z11_l._a1, NEW 4x4 COL. ABA44 POST BASE 1/2" DIA. THREADED ROD W/ 6" MIN. EMBED IN DRILLED HOLE W/ INJECTED ADHESIVE OR 1/2" DIA. TITEN HD CONC. SCREW F.V. CONDITION & PRESENCE OF ASSUMED BLKG. BTWN. JOISTS. REPLACE DAMAGED LUMBER OUTLINE OF CANTILEVER DECK JOISTS TO BE REMOVED PLAN NOTES 1. COORDINATE DIMENSIONS WITH EXISTING CONDITIONS AND MINIMUM ARCHITECTURAL DIMENSIONAL REQUIREMENTS. NUMBER OF STAIR RISERS MAY VARY BASED UPON ELEVATION DIFFERENCES. COORDINATE WITH DETAILS ON SHEET Al. 2. REFER TO STRUCTURAL GENERAL NOTES ON SHEET Al FOR ADDITIONAL FRAMING AND DESIGN LOAD INFORMATION. 3. CONTRACTOR TO FIELD VERIFY EXISTING (EX) CONDITIONS. CONTACT DESIGN TEAM WITH DISCREPANCIES. 4. REMOVE AND REPLACE ALL EXTERIOR STAIRWELLS AND DECKS. REPORT ALL DAMAGED (EX) BUILDING STRUCTURE THAT IS NOT BEING REPLACED TO THE ENGINEER. 5. REPLACEMENT DECKING IS TREX (OR APPROVED EQUIVALENT) 2x6 NOMINAL. 6. PROVIDE TREX (OR APPROVED EQUIVALENT) TRADITIONAL RAILINGS AROUND DECK PERIMETERS AND ALONG STAIRWELLS. RE: SHEET Al FOR DIMENSIONAL REQUIREMENTS AND 4/S3 & 6/S3 FOR ATTACHMENT INFORMATION. (EX) PATIO DOOR 5 `--- TREATED DOUBLE TOP PLT., EXTERIOR GRADE PLYWOOD RUN TOP 2x4 OVER COL. & NAIL &BUTT LOWER ONE TO SHEATHING ON EA. FACE FACE OF COL. &FASTEN W/ L30 ANGLE TREATED 2x4 @ 16" SEPARATION WALL FLASHING EA. FACE TYP. DECKING, RE: PLAN NOTES TREATED DOUBLE 2x4 BOT. PLT., BUTT UP TO COL. TREATED 4x4 COL., CONT. TO TOP OF SEPARATION WALL TREATED DOUBLE 2x14 EDGE BEAM W/ HUC HGRS. TO COL. ABA44Z W/ %"DIA. x10" HOOKED ANCHOR BOLT :I it .......... ......... . OF - Lu 0T T ci 0 12" DIA. CONC. PIER �- AS IN SEC. 2/S3 M Z SECTION \�4IiooiI S2 3/411=11-011 - (EX) SEPARATION WALL BETWEEN UNITS - OUTLINE OF FRAMED DECK SEPARATION WALL (EX) PATIO DOOR TWOMUNIT I I w DECK, FRAMING FOUNDATION PLAN SCALE: 1/4"=1'-0 TREATED 2x8 LEDGER LUS26 HGR. EACH END BEAR IN ASSUMED (EX) POCKET IN EXTERIOR WALL, F.V. SEAL OPNG. AFTER INSTALLATION STRUCTURAL SERVICE 6000 E. EVANS AVENUE SUITE #1-021 DENVER, CO 80222 303-759-2200 nmozer-renn@MRstructurai.com L70 ANGLES TREATED (2) 2x8 I O TO LEDGER �-yt`G J�`�� (2) 2x8 EDGE JOISTS GOA' HANGERS TO i TREATED 2x8 LEDGER 5 1 c S3 ch Acr TREATED V ID L 2x6 @ 16".j CD uj r MAX. DECK JOISTS 8 cr) ASSUMED LUS26 pAEACH END ND CANTILEVERED ,Q 0<_ENDS rw OF JOISTS x CUT OFF AT DECK T4rfu ASSUMED EX FLOOR JOISTS, F.V. 1 F.V. CONDITION & PRESENCE OF ASSUMED BLKG. BTWN. JOISTS. REPLACE DAMAGED/DETERIORATED LUMBER (EX) EXTERIOR STUD WALLS TWOSTORY DECKS,x Ist & 2nd FLOOR FRAMING PLAN SCALE: 1/4"�V-0" %-. .` - wv. 15v5 . %ice 1 / Sao 'Val 7V IF AROUND BELOW -GRADE PATIO TwOmSTORY DECKS.8 FOUNDATION PLAN SCALE: 1/4". 11.011 (EX; RAILIP EMBEDS SA 1 SECTION 52 i l/z11_l._a1, NEW 4x4 COL. ABA44 POST BASE 1/2" DIA. THREADED ROD W/ 6" MIN. EMBED IN DRILLED HOLE W/ INJECTED ADHESIVE OR 1/2" DIA. TITEN HD CONC. SCREW F.V. CONDITION & PRESENCE OF ASSUMED BLKG. BTWN. JOISTS. REPLACE DAMAGED LUMBER OUTLINE OF CANTILEVER DECK JOISTS TO BE REMOVED PLAN NOTES 1. COORDINATE DIMENSIONS WITH EXISTING CONDITIONS AND MINIMUM ARCHITECTURAL DIMENSIONAL REQUIREMENTS. NUMBER OF STAIR RISERS MAY VARY BASED UPON ELEVATION DIFFERENCES. COORDINATE WITH DETAILS ON SHEET Al. 2. REFER TO STRUCTURAL GENERAL NOTES ON SHEET Al FOR ADDITIONAL FRAMING AND DESIGN LOAD INFORMATION. 3. CONTRACTOR TO FIELD VERIFY EXISTING (EX) CONDITIONS. CONTACT DESIGN TEAM WITH DISCREPANCIES. 4. REMOVE AND REPLACE ALL EXTERIOR STAIRWELLS AND DECKS. REPORT ALL DAMAGED (EX) BUILDING STRUCTURE THAT IS NOT BEING REPLACED TO THE ENGINEER. 5. REPLACEMENT DECKING IS TREX (OR APPROVED EQUIVALENT) 2x6 NOMINAL. 6. PROVIDE TREX (OR APPROVED EQUIVALENT) TRADITIONAL RAILINGS AROUND DECK PERIMETERS AND ALONG STAIRWELLS. RE: SHEET Al FOR DIMENSIONAL REQUIREMENTS AND 4/S3 & 6/S3 FOR ATTACHMENT INFORMATION. (EX) PATIO DOOR 5 `--- TREATED DOUBLE TOP PLT., EXTERIOR GRADE PLYWOOD RUN TOP 2x4 OVER COL. & NAIL &BUTT LOWER ONE TO SHEATHING ON EA. FACE FACE OF COL. &FASTEN W/ L30 ANGLE TREATED 2x4 @ 16" SEPARATION WALL FLASHING EA. FACE TYP. DECKING, RE: PLAN NOTES TREATED DOUBLE 2x4 BOT. PLT., BUTT UP TO COL. TREATED 4x4 COL., CONT. TO TOP OF SEPARATION WALL TREATED DOUBLE 2x14 EDGE BEAM W/ HUC HGRS. TO COL. ABA44Z W/ %"DIA. x10" HOOKED ANCHOR BOLT :I it .......... ......... . OF - Lu 0T T ci 0 12" DIA. CONC. PIER �- AS IN SEC. 2/S3 M Z SECTION \�4IiooiI S2 3/411=11-011 - (EX) SEPARATION WALL BETWEEN UNITS - OUTLINE OF FRAMED DECK SEPARATION WALL (EX) PATIO DOOR TWOMUNIT I I w DECK, FRAMING FOUNDATION PLAN SCALE: 1/4"=1'-0 TREATED 2x8 LEDGER LUS26 HGR. EACH END BEAR IN ASSUMED (EX) POCKET IN EXTERIOR WALL, F.V. SEAL OPNG. AFTER INSTALLATION STRUCTURAL SERVICE 6000 E. EVANS AVENUE SUITE #1-021 DENVER, CO 80222 303-759-2200 nmozer-renn@MRstructurai.com �'�• TREATED (2) 2x8 I O �-yt`G J�`�� HUC28-2 GOA' HANGERS TO i COLUMNS F.V. CONDITION & PRESENCE OF ASSUMED BLKG. BTWN. JOISTS. REPLACE DAMAGED/DETERIORATED LUMBER (EX) EXTERIOR STUD WALLS TWOSTORY DECKS,x Ist & 2nd FLOOR FRAMING PLAN SCALE: 1/4"�V-0" %-. .` - wv. 15v5 . %ice 1 / Sao 'Val 7V IF AROUND BELOW -GRADE PATIO TwOmSTORY DECKS.8 FOUNDATION PLAN SCALE: 1/4". 11.011 (EX; RAILIP EMBEDS SA 1 SECTION 52 i l/z11_l._a1, NEW 4x4 COL. ABA44 POST BASE 1/2" DIA. THREADED ROD W/ 6" MIN. EMBED IN DRILLED HOLE W/ INJECTED ADHESIVE OR 1/2" DIA. TITEN HD CONC. SCREW F.V. CONDITION & PRESENCE OF ASSUMED BLKG. BTWN. JOISTS. REPLACE DAMAGED LUMBER OUTLINE OF CANTILEVER DECK JOISTS TO BE REMOVED PLAN NOTES 1. COORDINATE DIMENSIONS WITH EXISTING CONDITIONS AND MINIMUM ARCHITECTURAL DIMENSIONAL REQUIREMENTS. NUMBER OF STAIR RISERS MAY VARY BASED UPON ELEVATION DIFFERENCES. COORDINATE WITH DETAILS ON SHEET Al. 2. REFER TO STRUCTURAL GENERAL NOTES ON SHEET Al FOR ADDITIONAL FRAMING AND DESIGN LOAD INFORMATION. 3. CONTRACTOR TO FIELD VERIFY EXISTING (EX) CONDITIONS. CONTACT DESIGN TEAM WITH DISCREPANCIES. 4. REMOVE AND REPLACE ALL EXTERIOR STAIRWELLS AND DECKS. REPORT ALL DAMAGED (EX) BUILDING STRUCTURE THAT IS NOT BEING REPLACED TO THE ENGINEER. 5. REPLACEMENT DECKING IS TREX (OR APPROVED EQUIVALENT) 2x6 NOMINAL. 6. PROVIDE TREX (OR APPROVED EQUIVALENT) TRADITIONAL RAILINGS AROUND DECK PERIMETERS AND ALONG STAIRWELLS. RE: SHEET Al FOR DIMENSIONAL REQUIREMENTS AND 4/S3 & 6/S3 FOR ATTACHMENT INFORMATION. (EX) PATIO DOOR 5 `--- TREATED DOUBLE TOP PLT., EXTERIOR GRADE PLYWOOD RUN TOP 2x4 OVER COL. & NAIL &BUTT LOWER ONE TO SHEATHING ON EA. FACE FACE OF COL. &FASTEN W/ L30 ANGLE TREATED 2x4 @ 16" SEPARATION WALL FLASHING EA. FACE TYP. DECKING, RE: PLAN NOTES TREATED DOUBLE 2x4 BOT. PLT., BUTT UP TO COL. TREATED 4x4 COL., CONT. TO TOP OF SEPARATION WALL TREATED DOUBLE 2x14 EDGE BEAM W/ HUC HGRS. TO COL. ABA44Z W/ %"DIA. x10" HOOKED ANCHOR BOLT :I it .......... ......... . OF - Lu 0T T ci 0 12" DIA. CONC. PIER �- AS IN SEC. 2/S3 M Z SECTION \�4IiooiI S2 3/411=11-011 - (EX) SEPARATION WALL BETWEEN UNITS - OUTLINE OF FRAMED DECK SEPARATION WALL (EX) PATIO DOOR TWOMUNIT I I w DECK, FRAMING FOUNDATION PLAN SCALE: 1/4"=1'-0 TREATED 2x8 LEDGER LUS26 HGR. EACH END BEAR IN ASSUMED (EX) POCKET IN EXTERIOR WALL, F.V. SEAL OPNG. AFTER INSTALLATION STRUCTURAL SERVICE 6000 E. EVANS AVENUE SUITE #1-021 DENVER, CO 80222 303-759-2200 nmozer-renn@MRstructurai.com 0 00 ob No: 0802C1 ate Nov. 30, 2015 tale: As Note heet Title: DECK FOUNDATION FRAMING PLANS heet No. S2 1 4=J 1 i mc: 1 c ch t fu V ID can 1 CD 0 cr) (1) OZ c:) 006 T4rfu • 1 1 V) _ • 0 00 ob No: 0802C1 ate Nov. 30, 2015 tale: As Note heet Title: DECK FOUNDATION FRAMING PLANS heet No. S2 EXIST. CO FRAMING EXTERIOR 5 U EXTEND TREX BOAR[ OVER LEDGER E % 2x TREATED LEDGER/STRINGER A STAIR 5 WITH /4t1 Xe WOOD SCREWS AT E WALL STUD. SEAL PENETRATIONS INTC EXIST. WALL FINISH. TREATED 3x INSIDE STRIN( WITH GAP FROM EXIST. W, EXCEPT AT STAIR 5 DETAILED AB( TREATED, I INTER STRINGERS Cc OUTLINE OF TREX RAILING BEYOND, RE: SHEET A1.0 FOR DIMENSIONS A24 ANGLE BEYOND WITH 1/2If x 2" SCREW TO STRINGER & Y2 fix 3%11 TITEN HD CONCRETE SCREW TO CURB 811 CONC. CURB WITH (2) #4 CONT. TOP & BOTTOM AND #4 VERT. @ 161, O.C. 4 SECTION 53 3/411=11_0,1 TREX ANCHORED RAILING OR TREATED 4x4 POSTS @ 6' MAX. SPACING ANCHOR RAILING POSTS TO STRINGER SIMILAR TO 6ONNECTION TO EDGE SEAM IN SECTION 1/S1.0 x12 TREATED STRINGER. EFER TO PLAN NOTES FOR 0ERNATE STRINGER PECIFICATIONS P f -J P1I1VLL M I CM%..n CND OF EACH 2x6 BOARD HANDRAIL BEYOND, RE: DETAIL 2/A1.0 TREX STAIR TREADS, RE: ARCHIL SECTION 1/A1.0 FOR DIMENSIONS TREX BOARD TREADS OUTLINE OF OUTSIDE STRINGER BEYOND, BEAR ON CONCRETE PIER TREATED, NOTCHED 2x INTERMEDIATE STRINGER SEON 3/411-11,011 /411- ij 1 011 .J _ TREATED STRINGERS WITH LS70 OR 2-1-30 FRAMING ANGLES TO HEADERS TREATED 4x4 LANDING COLUMN, RE: PLAN FOR LOCATIONS 2x6 LANE W/ LL 1.5 SECTION \,S3 00� 3/4 Oil DOUBLE 2x STAIR HEADER WITH HUC HANGER TO FACE OF 4x4 COLUMN, RE: PLAN FOR SIZE ABA44 ADJUSTABLE POST BASE WITH Y 1t x 10" HOOKED ANCHOR BOLT IN PIER 1011 (OR 1211 WHERE NOTED ON PLAN) CONCRETE PIER WITH (3) #4 VERT. & #3 M CIRCULAR CLOSED a TIESW/ 2 @ 6t1 AT TOP u OF PIER & 16" MAXIMUM, RE: DETAIL BELOW #3 CLOSED TIES (3) #4 VERT. I I I_I I I I I I I I I 2 SECTION 6 NOMINAL TREX ►ARD LANDING 'CKING FLASHING AS IN SEC. 2/S1 EATED 2x8 MIN. LANDING )GER WITH (2) 1/411 x 4%'1 WOOD SCREWS? TO EACH LLL STUD ►T. CONDO UNIT :RIOR STUD WALL CONT. TREX 1x4 AT TOP OF DESK RAILINGS 4x4 NOMINAL TREX RAILING POSTS, OR ALTERNATIVELY TREATED 4x4, AT 61 MAXIMUM SPACING, ANCHORED TO EDGE BEAMS WITH A MINIMUM OF (2) Y2'1 DIA. CARRIAGE BOLTS TOP AND BOTTOM SPACED AS SHOWN J (,/I 11.11-011 4x4 RAILING POST FASTENED 2" EA,a TO (EX) BLDG. WALL AS IN SEC. END 6/S3, ROUTT HOLE AS NEEDED 311 a AT LEDGER CONNECTION ------_ -. Tom. RAILING POST CONNECTION TO EXIST. CONDO EXTERIOR WALLS IS Y4" SCREWS @ 12" MAX. PENETRATING A MINIMUM OF j" WALL SHEATHING TREX RAILING, RE: DETAIL 1/A1.0 FOR DIMENSIONS EXISTING STUD CONDO WALL WITH ASSUMED SHEATHING AND FINISH MATERIAL SINGLE SCREW CONNECTION AT TOP AND BOTTOM OF BALUSTERS STRUCTURAL SERVICE 6000 E. EVANS AVENUE SUITE #1-021 DENVER, CO 80222 303-759-2200 nmozer-renn@MRstructural.com 2x STRINGER FASTENED TO ob No: 0802C1 ��� ���` ✓�~ ^ -� ��"�} �' ;�~ • �y ' yi y • O BLDG. WALL AS IN SEC. 4/S3 ate: Nov. 30,0 201 • y y • �! it 04 0 tale: As Nate (2) 2x8 MIN. EDGE BEAM OUTLINE OF ASSUMED ---- RIMBOARD OF BLDG., F.V. 2x10 BEAM W/ HU28 HANGER, FACE OF BLDG. - COPE BOT. AS NEEDED TREATED 2x8 MIN. LEDGER W/ LEDGERLOK SCREWS TO RIMBOARD, SPACED AS SHOWN & AT 1611 MAX. 3 SECTION 1\153 11 1- /4 11 -1 0 �heet Title: eet No. SECTIONS S3 City of Building & Inspection Services Division 7500 W. s Ave,, Wheat Ridge, 80033 Date It a a w IL WIA Address: City, State, Zi CMcMQUE t-iumointq: mecnanicar W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub. Other City Licensed Sub: City License # City License # Complete all information on BOTH sidles of this form � A. { 1! mM y � 1P ; • � mm 1m ! imount of materials to be used, etc.) wc v Cc Olt, SqFULF Stu's Gallons Amps Squares O r mk 9w. ttiry Et IT) 15, fN kNo o - 4k mk 9w. ttiry M 0, Et 15, CA SP M 0, 1 2< < \ \ rcr `ystem\i)d/�\\�\\ ing i» »<%: x & General RequirementsManual caltril t, (ire wal conditiorts c: c . ift d Contractor W� 'fes Anachment Tables cation Plates NOW Refer tca www'Pf.com for a complete fist rc Data Sheet, and ChetnicalResistance Guides, For roofing contractors and &s&&UWM H*ng to build void hxWes flelping to assurer best and safest dioice hi rc i`rrr WHAT IS IN IM MANW? Utis Baa contam the following smUom Welcome Guarantm Rtxi Ocsign AplAirAtion Guidefirim Mechanically Attached Roofing Systm * Roding Details i' - affordable GenuineSlate Roofing Systan REStDVffM oto ' Grand State, Grand St* 11, retry AlansiOnO, Country MarWon* 11 Grand Canyon-, Grand&*1014 q and M Shinocs, -, TintbeflaeW-, [ fi€O Natural Sha"-, Tbti TimberlitO CW W� and rimberfineO AmirStrO it * arc m mio This Manual contains the latest inforneition relating it)) the 2ppkation ofGAF's call ,, F aaaclied ngle-ply roofing "ems and is based on wr ym of eqxiience in di conutw=1 roofing field.. It has bent impared as a gentaal guide to assist arclifteM engineem rooling, a rtr tors, and ownen; in the use of our roofing *tam. manufacture-s and seli rangals d aw practice it -ait tat or engineering. is not ffVwlsible for the perforniance of its products whmto its products is caaasrd by such Hein s as finixoper building deign, constructimi flams, or d in workmanship, 'ger responsibility, rernamsitla the irdutrc, maling onntractor, or tion de ° 'lvs illusualed and desimbed "n am faun€ wed soldyy for guidance purposes These guidelines should not be constmol is being all- incimsive, nor should dry be considered as a substitute for good application Ouler no circumstances does GAFhave any, liability for expm-ci arising out of or xwxIaled with the sorry, lircuumraf a ing materials or ar)y Ww al eg or rnakTials upon ffie roof to wiudi new GAF rooltng materials are being applied, Infonnation containedin this Manual is presented in WW faida to the, bm of GAFs GAFknowledge, da not infringe pori any paterits, foreign or don : tic. As a pxt of its continuing efforts to improve dao peffermanoe of its privriucts, GAF periodically in", . np to its prWua and applicafion.Wificatiotw The t° ay resem the rioit to,dianr or modify, at its dwtton, any, of the inn ati b, specifications, or cis rained ire. "s Manual superseiles all caWo&i and mous manuals, is Your Ekst and 3 (lowel GAF offers d guamntem for a fee for all tooling TAM Vocifications yrtab in this Manual vada irtoalled by GAF F hig, CmIractors in Mconlarm r dr Kim grad CorAtions Set bdi in this gl ul dw dures for a �l All GAF insulation, fasteners, ils,. deet joint cor r t, t reiptited for guarantees I otherwiseaplitowd in vatting by a Field Sereices Manor or Director prior to it s allatio , All guararaced moft a�m� atum he a accoobvice widt the OF flashnig in ft Marand, f FAI be the sole judge as toultether or Trot a roofing guarantee will be W%M to never any propoA or alt W rod The ewitancr 4 a gtianuitee arid its eflactiwness or the continued halitfiq thereunder is contingirit upon pmytuent of GAFs guaranim fee and faawtern in full to than roofing corawtor and materiak CAF has no obli tion to isstre a roofing guarantee y roof. Any inspectort Dior to issuance is solely for the benefit of GAF and does not astute a waiver of any tenns or conditions in the g tee. err the evert that a rool sytt does not conform to GAFsstxWwh and a guarrance is not issued, no portion of the g ira nice fee is refund". GAE will of Ovitract that indicate that the ownff or architect has the tion to accept or refit tlae tee tqM completion of the *dfir2ravls not Ir ataual inay Aso be eligible for GAF guarxitoes. For further inforination, on, guarantee requimneuts for 4proval of roodiftcations to published spioa tions, cult itfr GAF at WW4411. CO is not mslionsible for consequential darnages in cap.* of nd systerxi fail ,. t"AF has no control over a building's contents, type, Vautity, positioning, or projection. CM guamtee cannot be withilmwn once it has been i< although it rraay be cell l sulviefiently by GAF for violation of its narns mid conditions. 204M)9OW Roof owner, or mat comiltant =*Irr'lui be. used in, roofing spteois to be guaranteed by, G.AF 11he following is a list of elioble 1. Ewt6uud* 25 -yea exterided-length guarantee . Fv rGuartf"a'ad eximiled-length guarantee x gverfumd Tel real rumbrarte ( h) b, EverGuard bdmneO TPO 70 'nil Inernlitane (fl ) c.. rGuard F aril rrt (drra ) d. EverGuard h tai aail trseatrb ow () Roof Instilation 1he selection of imsulation tytx�, thickness, and configuration consultant. GAF reseroft, the right to accept or ret any roof insulation as art acceptalile substnae for GAF rod syaerns. GAF Fbergy(Actrilm inadations rawest be. uwd in toidling; to be n teW Ivy CAF. 1, For mechanically attached sy terns, a cninir urri ref taxa laym of nuadation, are refted for both ^25.a acrd :vw EverCittate exterided-lanoguarantm . For laatlr say r, the top layer nuist be a cover board, as fold a. high density wwO fiberboard b. I)msDwV Roof Board c. Rod Board . DensDee DuraGuardDens' R(d Board e. SECUROCKO Rodd Board f. high -+d nasi I X g. Blue RidgeStrucloile In akhtion, buildiripm gmAUT Chart 100' o crs) in height rrr have a r - io d" (0.9 err) . wall to to eligible for an -1 gth Di fledge" 25 or 30 -year gar tee, All staiidant TPO inantirtnes guaranteedfor 25 yearseligible for die We,[IR(xr Guarantee Extenskin. For inure inforniation, s. •t .gut r. Air/Vapor Retardm for'� ... l" extended -length ^ t , air/ requimd, follows: a h installations with operaW in the wall ihat 5 the mai wall am. . with otstallafitats of tti" (3 tit) wide or greater recuhranes with Aide taidumical auctenent that es " ( t 50 mm) ot, (for 1W (3 m) side. the reorements for an air retarder am t upori bldg height and fastener dereifty. CAF Field Services Manager for airetarder r ret". ReafuAirw flashing or cap flashing is required; "posed terminabon bars ate not acceptable. Ror 1. for hvrGuare exteri&+Ivigth guarantees, use EverGuiud* of 6" (150 mm) of 045reinforad TPO membrane with 3' (76 2. Galconeed-liaseii urtal edging is not "table for r Cow Tape after ptiming NA the metal and the TPO mentlinine for guarantee len gds up to 15 )"K . For EwrGuW*l gra° the nienthraw t., , EvetfWard R ie flashing accessorim- am required, $ & Y. withoutII' x"! Ditectat- a , ow a cold stanage buildin& wilm a ventilated plenum isolates the cold ";iiea fim-a the roofing " , em and substrate * on structures having intuluit or piping bdwmi the mof deck in channek below the top deck sudim * on ", that haw, an inadNitate number and Vacing, of ""won loints or antis # on any structure vAtere there is limited or no access to the rod * on a roof "ped for or used as a water -insulated orgirty root * for any structure where high -heat or Imandity, corrilitions exist such s, but not limited to, firweries, creatneries,laurstries, textile mills, pulp and pqw plants, swimming rr.orns, and carpries when, ronfing am an cisfing mid s%Wm that contains rrroistrrre, that is not fully adhered to the substrate or rod or prosides r y pripared slid 4 t continuous solid end WwJdag Ott ttairr' -irr ar foam any unusual conifitiort not vecifIWly approved by QAF y high-w1werature cordmosi that al the mof memlirank winjierwure to emW t° F (71 *Q, or 190"F (W) for Ever Guardrng syAanss. Any it "cars made by GM am for. its m1w-wily aid do not stittrte a warm &lany r di' guarantee. Shordif a fF Field Semms Representative iihsaw comlitiomon the job site: that do not conform to the requirements of this Manual or standardg such iti rlll t to the attention a tor. GAF, at its sole diserefion, has the right to ralutre wrrectice actionas it dem necissary to conkian to the requirenients it this General Requirernews Mantral and the requiremerits for the eAame of the tF roofingsystein guarantee. Provides a quick referenceof technical requirements * General Sustainable in * Building Utilization Tear -off or Re-cor * Roof Decks Parapet Walls * Roof Drainage ints * Awa Dividers Equipment Mountings Fare Resistance Wind Performance Piic * Water r Trarisfer 0 Proper roofings),sian design considerationof many f Alt Cl "s ex is in r n . arol eot in eapteering, ard-gaectim specializedulti r coinpany has dmades csf anereave erperfiew in dee prActical aspects of roofing, Our cWhence sugWsts that careful consideration of the foil will provide am singe -ply tal sd "s i of 0;10121 V s . "E' t FNERGYSTARIO as a joint of die U.S. FAivironmental Pmtectimi Agency and the U.& Department of Erriergy. It is designed. to help our nation nuirvey, and to protect the etwumunent through enerVAimit productsand prAdWM E aci t "ces can saivbuilding (mmers significantly their enerV bdhvAth similars gas endown, without sacrificing fratures, style, or comfixt ENERGY STAR* consuaws, coturadors, ardutects, and property owners usage aim knowletlgeable, er t The LEED mitt in EneW aW ErMnintuentalDesign) Greeir Building Rating SW is a standard for ng lair c , esa -� t " 'ra e buildings. 11ve IFID Clertificaboa System is a puipm that a , for satisl�tog g ildir i mad l tts. Gmn CII is a for green building guidance and b .. i dw includes an onsite assessovent by a thad parry mid is an alternative to the LEED rating system. GAF'sis that to " , toNSF/ANSI 347 ' ° itfor * i ,t, oo br its: cis Standard is the` itl of l y g is Standard Wincludes .a arm the liroduct life tjxk fican mw material odruction thrmigh maradwhicing, me, and and life managenvent. GAFs uard ane* IW Roafing with energy rff`dency and sustAinability in mind. This hig - perlortuance, reflective roof toeminne is for solar mof installations. incremg use o(budding integrated phi I • " CR has highfightedl the challenges famil by roofing menbranes to r IwA sualight, and Itis. GO sciennistss bay arauxt a new grade of TPO single-plymernbrane that is built to hxWk the eidasne demands dut new toollop applications place an cooling membranes, EverGuairl Extrerne" TPO uses proprietaq "slicers and IN akxbm to achieve wrathezing, pulormanoe far beyoml current ° Eve6trant Extreme TPO can be hstalled up to lit years prior to the installation of Wu ccs: Installation of ovabuirleir will not affect the membnore perfortuance orwarrattly coverage o(Ever(juard Please, coritact CAF below installing any overburden the A Building unl a+.a on can have a significant impact on roi- ng selectionsystern and design, assist common lasilc ng utifization considerations are as follow extremes in internal a Ten""WrObovidity Fxtremes in internal aeuriwaWmArtankfity are ra often associatedwith d rer buildings,, s m . Ing facilities, g Icilrss, f ingpl tsx it li "lls+, and ' tin t f f .. makes these building is that the pronounced diffievena in sWor die budding Interior and the " can cause a pronounced valior flow throtigh the roof assernbh% This can result in a siginficant build -rip of condensation within the roof assentleb, andsesere deterioration of both the roof assembly itself and the SOAXIMal deck. Rd"nnu indmk, Incorporation o(a vapor murder at deck level to control raw Dow into and thrm* the mof awn*, steel fasteners to minknix potential for condenstbon-related de*-adamict of the mot s1stem; limitation of Mwftafiom through the ro4 deck, vapor retaniff, Positme Inkmal Pressure a + centers, may cause fadure of the mofing system due to pressure — uv, of air-impenneable deck construction, such as poure&in-place emcrete or Insulating cellular concrete over a AM pan; — Altematudy, installation of an air learner, such as pdydhykm hecting, at ,, Reaftep Traffir^y" Abuse Many nx&g inslidlaflons, are erposed to rail, grew, and chemical contamination in excess of norinal wiliorne contaromarim Thew conditions am ama ofteii wiciated vith restauvints, food la Tantsdc°l and phartnamiticallots, ref bring rn ttf�,P tang f `liti ai s. rig materials ° 1 cation hunifie-iof contaminants, and call becorne diratile, swIl and saften, or dissalve, deleding on the material lbrundation ad contaminant , Long-term exposum Le,, , . brimemon testing of reeling autterhd and sirafic communant remams the prelerved rr of detennining mairroil m, Fven dxn, unforeseen cort"rAtims of contaminants, env a ntal expisme ,and var.ati in contaminant conextitrabon prmntan prediction of resistance to contaturriation in all hitt the. most oasurnon situations, -- Isolation of contandriated with ri4xctafton of roove fievent tod meatlurne replactanent; dig-er washing of roofing mendimm ivith inodende pressure; - i r(xAT slidlage/exhaustcontarninating snataial% i.e., grew, tr4& Please reler to www gad cout for detailed TPO and PW. t` tial charts.Resistance CAF guarantees on xq GAF inerobrane, including TPO and PVC,, do not cover darnage due to chemical contamination. Pre decision to r to r/ anrA-4ng roolingysteitt before instilling a new roofing, is not ahrals clear-cut. Although not an exhaustiw,list,, the folkaving additional elemeas typically require consideration for any remofing — Replacement of a r structural truants; — do t t of roof access; — Renioval of unusedr t and associated e"pinent rto tinW _, Rerrounting of roift equownt to allow pTW roofing and Bing Whitojue, -_ Matching of architecturalefernerassuch as al joinvier Inewwork R 'r of deteriorated parapet xW pentliousewalls; Protectioncl mating mernbrmie by rt is of concrete irivday or t, T -n FacAm that sl' aeir or code restriction),, Structural weight dt i F More than of ' in roof am is vA Flashing height lt'nti --Need to midi' , MAN FINWOMINWANNINOM routers. Wmin"fingmwataten* — Plan a war -off strategy so that rW drainage pattenusare never Wodwil, and so that construction umTx is directed away from new rod areas; — Protect new rod areas Aumt to tear -off areas (wra dK Re-cover Facion AW i — Need to ontarnize Disposal ; Difficult access to trite i — Remove and reliace all wet roofingin Fads; rttnte ace pirluratim. ft-a� Over Cost Tar Pitdi Roofing ter tra has oils d tfr h ul to w rte d rna d `t OOW tate air 'x . flow"through as into ifs ttil ng For tris caro t re ng gPitch Md, tiarrrat is data a std to first , tbe A the ex and reduce die tengwrature of the firtisl ds , wirich inbontim the P*Otj2l for flow Airs_ 22 gauge (Standard Wapprovedsteel decking is 22 puge in drrckwssi. 24-26 puge de& mqWm.a Cid geld Man "s or fkmcWs approyA lb rge sleel decks usually reTjim ailditional mechiancal fasterteri to . ruble anachinmtperfuromm, ig g� 22 high i sttalty gal fa k , s tss eat rle nam t t — Alin, 2,500 psi compressive mostance (98M66 kil siluare it e . Min, 2<" (1 ntrrt) dfi , strut. d" 002 rnnr thi { ash-in-tti ). Cannot be wet or frozen. If is dderrynned to it must be afloAW to dry, — For hisulated decks, iaeod renters of eqwvaknt arickjgm to the Md insulation intut be ptuddal at peorneters OPernm toast star and to provide for the nailing of the Ranges l flaswn& — Ridges mid Wier irregularities axpire grinding to provide a th for ated decks, traders must be flush with deck Wren l� sug insulation } to the, deck i taa a itralk Pliftle x it tg D4'1, at a m1c Of I gaJAWAM 0.8 i allow the lidiner to dry for to the apoication of die roAng si Pre-aW CbruvWe dt are usually manufactured as plx&or slabs and constructed of 1 and cement and solid aggrepw, ofini they are made with hollow am to minimize tfteit ` ht. All eldortned pands must be relilacA — GO tevorurryeads a rrsirrin urn r (t tett) cellular ligh gist c ConC l t i iati fi t is it sulatlotr 1 " ti in tlt' r a RMWM mai mAt secumuent of the difficult: must be m ring or drying of the fdl i the of 1 ruernbers, t r not i ave open to pennit venfing and drying of the mof fill from lel wow Plan" --• Min, V (25 nim) ntxnijiW docleaess. -- Tongm & VMW or slibuntedges required. — All b0ards nutst a raftat ewh end ad be securely fasterwd. Lumber should%kiln dried, — Check compatibility or fire retardants used tD treat decking with mofing rn `als. — Decking g s ou d be y' Pd -- Tfa R, may be used on mood decks when .` coniply with i building codes PhWO044mented Stim" Bond (00) - &lost be installedso that all four Ailes of each panel bear on, and am securw tA), joists and cm bk)ddng; the panels must be wmmd in accordance wiffi AR -The Eroneeved Wood - Pmels mint be imWled with a Is, to 1/4" (3.1 rour to 63 mm) gap bftm panels and must match vertically at Talie and staple Ustening qmm may be ased on wood docks when dwY COUOI with but building codes c agmictes sPadng Coniuk local building codes for specific requirerwits, GYPUM e - an. r (51 metra) mnfoming mesh and pmmmtf required for Pnovd-in-plam, rs aolithic decim -Steel-trinforced aied for pre -cast docking remits, - An geFak ridthdrml nsistance as recomineryied by the fast manufacturer must be ed. if propm mechanical attachment cannot e achieved, contact the GAF Technical flodine at 1 R - i 1 for asswmice voth insWiation recomumnilations. stuf -cat cat fromn, a poured Mrsum deck is not aril to mwive a Toole CCOMWOOVS Alin. " (51 ) thin - Tongue & gnxnv panel edges tNuirei or insulation Cornposite dois for rise with fully adhered sysmus require a GAF Field Services plat "s or Directoes approW. IE -.Should not be insufted ow high hwnWty -Rill structural wood f4w 4A pane6 must be h uplift and ral ffwmmt t - Mira. " (51 ) lbsubtang concrete insWed ow structural concrew or mVimd o haw a density of 22 pcf (M graur/ciAric nietecl- Individual deck fi a#* when their vedrOmom these GAF mintrourn thiclinesses, c(OnrAwiw strengths, and fightwmight imulating coixtete decks must be poured and unacceptable in AlwAx - Lighm*fit ftmiating concrete should no be red during cured must be mumW and roaced. (Iteck insudlation of teadmaster - Roof deck must be, instilled by almdumer-approved cOntractm to -- Mira. 25 puge f'1/4" ? aaaaaa) *Rh '/?," thick f 3rr ) ,r 1, or polyiswymunde instilation Consult : a GAF Field Senim Manager For re `ng and re,covering req€rirerne s. Most rorrnc StriCtural WWI Opes am suitable sufor die lhishing Uidard-firfish brick and concrete block with standard tooled Met W. joints. - SOC14ace block,textured Mod and brick, and traded nxwW joints rite a carnerifitious coating or plyrwood facing to proMe a smooth acrd even substratesurf trowel,SW wood Hoak or rernassbile form finWL Judges and other irregularities requ"re grinding to provide a suair,th and even substrate sufface, — Stucco finish and FJFS systansmust be to the uniledying sit Sheet NOW Min, 24 gang steel, Mm .032" g n aluminum, w Min. 'b" (13 nun) th' ili o -in ated facW panels, whitrw most ai'.ow secumtreat of flashing at prescribed in& Medianical attaclinient, to Mmm 1 i$ is not acceptable. — tW of gypsun MM decks rexpres GAF Field Seniceskea, Mxragex's appmal, #xJ# ""? e e IE NattoWd building codes genually repirea n ' irn ' 'I2- (b.d to n to t to positive dn bunom' d a. reu t a rl itlr r r �Ida or rrray rrr l t' lry dtis Mol 1n SHUMOns vdim rod edge muhtions,window/door height iho hole locations, roullop equilinient mounting, or odw factors ptrient the, it nu of a full sl in system, a combination of aMfional drain l s,upered saddles, sul cricket to dued drainage points should The Inaction of a structural exparision joint is to mita' effect 0( ~.s and roommeou on building comportents and to PM"t 1195e st (Mtn admwly a'" the mot. 21re location, acrd use of building structural opinsion Jonas must he cotuidered at the nine of original building"go and am the responsibility of the architect, entineer,building owner, Wist be tinaor d dre break in the stnxture and nor ternimatedshort of the end of t Should never be bridged with insulation or roofing n , . — Construction fiesbe sed in order fore *is is to function y. — Extend eAWWon joints at teat W f s&ace on curbs and we either a Flejubje bqumqon joint Covers or metal cal,6 or covem Alternately, a low pnifile expansion joint can be used, see EverGuaidO details for DesignConstructiom drainage patterns so thel, are not bloclied by any structund expansion gourd. — Where possible, position walkwacsaccess points to hour Mof traffic mff expansion Jain n for expansion l nis at locations of antic c.. — EvKAlue PteTab ExWWon joint t ew i Prom mounting of eupment is an inipuriont wno&rafiooin t should be ttl in such a way as to provide adetluate flashing twight fora r ark , pa re r `c i. t democe arta beneath the equipment to f 'li sWern i lati Conipatibifity with roafing and it ng nraktiaLi so thatstandud flashing methods can be rea&4, aMK4 Altomately, fightweiglit cipoliarent t lines houDed on wood binding or do not penetrate die roofing qsixan, iia NOT use this Mie of application for leery egrai raerrt or gas a°strrdu t Brae; or where excessive movernetit can darnAW thesubstrate or menibrane. t c document* fm Global (Factoty mutual) 4450 and 4470. — lileasures resistance to upward pware applied to the * American Soddy of Civil Engkoem (ASCE) AM 7-10, -Mittimun Dedp Losils other Structurw Rquires detailed calculations, to detemone acuW wind pressures at ififferent regions of the mof. — Referenced by building codes. a IE Perhuder Haff Sheet T21Ae The `ureter area, as defined in the above table, may be adhered as an alternative to using half sbect& When adirring die Munder the number of insulaftlasteriers, must be inciessea in these arm, r of to the insulationt section for adhered Refer to Ox shed lay details in the rnechaiocally attached, "m serow (or raquirernents on the `insudlation of these half sheem Now When designing for vnnd loads, that the pqw building classification, (clased, parfialty closed, or is usedif & building has large openings (i.e., do& srith large loading hays, etc.), Inilooper chisifications can result aro roof aaadimem faure mised by deugoing to lower loads, than actuaI4 eAst for the ming in qwAnit, Thermal tramussionstmiards harp been established by btrildirrg codes for inost WWiw RW insulation installed alime the roof deck is a practical mem of achieving the necewry effidendes. in addition, rdlective membranis can redm the hear load on air contiftioning equilinient, as well as provide a moderating effect on the temperature in finnatinty to the building. — 11teimat Thinsuddance, The another of BWs { a ra that the a (its sq. rya.) nple of a l material y in one, hourwith a Winfienoure difference betweerr thetwosoxhicesof t degree (-170Q, — Thermal Transtrattance aWics to an actual WW material assernbly, and as such is a quantitafise physical y that can be used to repaent the overall the of a, uL — 1hennal Resistance number of ilegrees diffetence Mween se) that is 'red to an eneW flow of 1 BM through a l -s fsxat (il.I sq trs) saingle of a givert inaterial t in one hour R -value is the reciprocal of the -value, for determining insulation rolunement& Iteflectance A measure of the % of solar energy that is reflected away I)A materials absorb more heat frorn the sun and can be to 7W QIIIQ hotter than a reflective white surface saine, ouwde temperature and conditions such is location, etc, — A measure of the InfimW radiationa mof surface. Unlike. ' "ty may e3 by dirt. car discoloration of the warfare of a material, 1* following r&mm pmvkk- useful information reganfing — Provides detaiWileso calculations and material energ transter Worroadon utilized by mechanical engincers in the design of heating, ventilation, and air-comfitioning s)Mems- - Suitable for complex energy miluation considerations such as solar hea gain, exterior shading, WW butitfing covelope, building us%age, and fighting, - NWA Energy Manual a simplified coif for iletermining the mount of y to t low roof systcrrr, a," plifted inethod for determining tlae amW cost savings resulting hom the installation of additional rodireatlation, suitable form t n f . DOE EnergyCakulato r -- Go to 1. to n gall " CalCalc laths to find tae Coot Roof Calculator — This tool measures die savings for fir", with non -films mot surfaces, : # .'T single -ply blies do not include raw retarders as a standard assoubly coinixmit For these applications,there is a natural transferrd water vapor into to toof assembly dunnga portion of the year, followed by a natural transfer of watervapor out of the mof a. ly during the balance of die year. Under r tonnal conditions, this type of cyclical W vapor flow does not cause a significant deterioration of ati or reduction in insulation, th l Hower, for protects alone there is a significant difference arr raw premie between buddingn extenut, the vol vapor flow is naa fi greater, mid control of water vapor transfer into and throu lr a n ,, ata an importantconsideration. Without insulation became saturated with aim, ith a the aeafracticna in i f ' t al . Structural or condensation into tie building trileedor nay also occur. Vapor flow is 'referenced in vanousways. 11w following is a desedlition of conurron terminalogim. IR —'foie finte rate of vapar transmission through a flat material or construction inductil by vapor pressure ififlerence booseen two specific surfaces, uniter Verified temperature humidity i ' s. — Units of permeam are opessed as. (gr) / (it) (sq ft) (in Rg). r. ,ance, or perm tath%of a material a perfirunance evaluation sic to a saarjAe of material, and not a stwif"ac pq*q of the material. 0 Relative Rianddk Relative humidity is the ratio of & pressure of water calm present in air to the peaur ofWly sats pater vapor at the same Relative humidity is expressed as a percentage. Point Temperature M The temperature at wWch air becomes saturated vidt saturated° r (f rev five humidity) and condensation begins tof — Dew Point Temperature is expressetl as OF vapor- Temperature a" Relative fluaddity locations, mid flows fmar higher to low pressure wWw ,, the higlier the temperature, the higher the G. lly .e — to determining the need for a vapor retarder for most typical conditions, the esienor varder temperature and the in*= winter relative humidity am the most critical hiders. building JIVAC dmign professional or the building operations manager Relative ficairality can also be m measured Vow Retarder Location — A nuffitier of basic consi&nfim forror rrtaa the need and location a vajirr reurdet, Deterituntrig the need and lintion of the raw retarder is the responsibility of dhe professional.ilesign m are intendeil anteto be lei as close to die "warrr site" as possible, Normally, this places the raper mtm*r dimitly on the structural deck or dire# ow a minimal layer t ear Insulation or fire knim -R A officierit amounttila on matt be installeil over the vapor murder to raise the location of the ifew point temperature Am the lesel of the raw mumfor 0 Sealing At r — Vgw retardw shall be completely,. at all perimeter and Penewfion l ti Sealing methods sliall be in ice with tl td raw retarder being installed. --.Air leakage at perimeter and penetrations vallsignificandy reduce, the effixtiveness of the vatior retarder by allowing air to penetrate into the mof assembly, where it cat condense and cauv toof rieterioration, PAdMing USW — Normal building irsar sircit as ofrwz, schools, retail, warehousing, etc will not typically're the we of a retseder exapt when located in tk most minfierly clirrta Budding nunin , food processft paper manufacturing,foundries, ternMatures and humidity conditions will likely require the iae of aseta to in the most i . tes) —11rese generalizations are no intendoil to substitute for ac ud vapor flow calculations specific building and dinactic ounditiow. IE Vapor0 Iht Use Against The Use Of A — Vie vapor rmr* together with the tooting mendinme, may scal entraptierl moisture wolurt the W system dua can eventually the insulation, kl the membrane ar, in 9MMUS form, Wister it — In the er t o th r t d membrane, the Vapor retarderwill trap in the insulation and re6ft it through punctures, breaks, or poor seats in die vapor. This water may move some lateral distance turn the mii lead, drr. mai It rrs cacti l ctnstrlah may t� numb i5 '' rid ark — A is a disadmitage or stormier, wtwn nri tar is generallydomwdr h the humid air t infiltrate the inn " " through via diffirsion through the roof tnernbraneitself: if rs, molsture c t.ividew mtbin the rig sl The following arab inforroathin raw irtardem- - f A Energy Manual In A, in NUN= Of FASMIM inswation TW Met 1 tr7 1W comer 4A sin, Isocyanarate 4x8 tr 6 6 6 1. j 5 5 Peruse 4x4 4 4 Wood fiber Any 4x8 any 6 6 6 Fd"W x any w®r U PMW P ty �Mw US t " — i.r 6 6 6 1X 5 5 C any I/T*--f. IT 6 6 6 4xg21.x" , PVC only Fanfold- 2-1-2-1-2 y@7- ry 2-1-7-1-7 �b TM Of IWAATM T Deck Fastener 'Plate ftneh-"M (mini Sket — aft pagesliR1fG ##*' y1I i. Stanittird (#1,27) nae iJlF73/4- trough the deck sheathing 5A71.Lt.4ITC " SR) g(ry#d4) (#12 ,3" a�t d" : in ' h dw '. Strvotural Concrete DRUL-TEC' (#14) DRIU- ' a a. ke " G is p gg 1" di shrank 1 Insulating Comaxw DRIII,-TEC- HD (#14) 3"Galvalurne 3/4- thread throtigh sted loon Gypsum Concrete DRIII-- " Potyruer i"Galvalume11/2' th into the deck FiberDRILL-ITC NYMer Screw :i" al lu t 1/2" thread into the deck *Aftadullent Wrivanents to ineet delemiftiedt c tt on deck 4,pe, specific fastem, etc. "Fanfold attadunent spacing is fora 2A' " ,6 rat x I S its om , ** PVC must have.A/6 o7. (85/170 t s x gr) t rs , yrsuttt ttt ailed ow :tel he placed erpertdtc lar to the deck flutes vM the etl t1w fft MdaceforproMbearingaWm. in TAKE FOR MECHANICAILY ATTACHED SYSTUAS �4 �Ahos(o*) Ty" Pattern Pattern ILL-TEC- 2 W baW 1/4" dmgh the deck I2" o,c. 6"o.c. 450 DRILL -Mm XHD 22 ga.I)RIi standard 45t) I I1H 5 4" doublecadouble barW 4" duough the deck 12" o.c. 6 " o.c. (33 Itsi) 350 DRILL -TEC' RD 2""barbed 3/4" through the deck 6"o,c. :350 I7R,i.-'IC� Ilii (14barbed '4" through t " a.c. .� 750 DRIMEC 3 (21) 2 V4" double h I " o.. 1 "o.c. 22 gL Ido 4,50 1)RIU- Of) 2 4" double ba `4" 12" ot, (#15) 1I) the 12" ox, (ti" sidefield gwm 13) 450 I)RIU,-TEC (15) 2 3/4" double badW 5f " I2" ts.c 6" .c. 350 1) IU - IEC " (15} 2wbadied 4" "r.c. 350 DRILL -TEC- XRD a" double babed 4" through the dwk 6" ox, 24 ,50 1) 1 .-7 (;- XUID (15 2 V4 4" the 6" c.c: standard,350 FH DRUi: "1 C RD i 149 2318- t1i) 3/4" tth " o,c. ItRIt,I*-'1C'� 'ii (I4double r;350 barbed V4"thmugh t "qac. 800 DRI'II-" 4 - Iiia (14) 2 "" barbed 1"iryw the I2" o.c. " a.c. Wood Plank 800 DRILL -TFC- (#14) " double barbed t" into the deck 1,2" oc %" �r. w 450 D -I C- III) ( 14} a " barbed XHD Through the deck "ox. I" Neffaftat Wood Plank 450 I) -i 7 111) (#14) " a lee barbed Through the " ox - 525 I1. €I -7EC" RD (14) 2.W barbed XUD Throughthe 12"ra.. " o.c. ' iI Wood Plank 525 1���2* 1e h 12" ac - ox. t P6f is attachment piftern to provide 90 lb& per mptare foot (439 44nj of u0ift resWame of the from die deck Note: going fir Factory mutual requirmnents, t the current FM AppruiW ROOFMV and FM ApRWAIS Stitudaild 4470. M EE MY field .beets, except ixiwa noted) v 50 DRILL-ITr DRILL-ITCHD 2barWThrough ,. „. „} eck a+ xm P ,i gl�P 350 ppv�y�yyggq{.0 gg��y'55 DR 11 -TFC- 15.E (14 +'gda a. 3,SeS a ba rt��',� Through (. 6 p. V3A .M. 700 DRILL-7FXy- HD 2 3WAr lvaArWed i" into die deck 12' o c. 6" . 700 (#14) 2" dwNe barbed Vintothe deck 12" .c. 6"sac. Concrete '900 DRILL TI C;' duke lilt M into the deck 12"1 O.C. 6" o,c. 1 DRQTFC- eke 2" doubbe badW I " into tae dftk 12" ox. 6"sac. 900 DR LL -TEC.— Si e 3/4" ISM 1" into the deck 12"t ta.c. 2' Ox, 450 DRILL -TEC" MID 2 . barbW �J/4 °d .Rl `M *^R t� 5 rM � Aw +9.&. }p o MTM '4x.1,4.. 4LwoldotIIRILL-TRC IBMWa#R xCl ) (1 } 2" e rM a flee f . x 12" ox '°. 22 gL sUmdard o .St3 DRIU-TECH" 111) (1 2 -W Wind D) t " dmigh the forra 6" st.c. 3,50(1 fililM-TECH" � 2" double Vit" a the f 6" .c.. 350 I3it LL '1 Cy (IrXHD 15) 2 :� 31'~x" t the n 6" a�«e. j. 3 0pp C"C�gy� YA gy y5'$ DRILL -TECH % (1 AXM - le the y " tl a tl&& 2 6x" i&.. le 24 gL 3.51 IIRILt.-TLC"' lilt (id) 2 wbarbed XHD 3/4" throuet the loan 6px ox, 350 tiltIU.-TRC "lilt (#14) 2- douMe barbed d4'" thmugh the (offn 6" oxc. GYPSUM i RILL UM Polymer ,. 2" bleb 11/2" hik) t Tot, fiM sa.c. concrete 400 P*wr Screw DRILL -TEC r barbed 11/2" the deck Tot, 6"ox,. $� gyDRIU TEC- olyinfT Sam 2M double Wbed 1 .112- into the de& 6" o c. wow FAW i0o(I�)�Rlf 'MC " R'oj 2" J.. 11/2" into the 6"x o c, *90 Of is tt l at paueen t lbs. per squire (439 kg/m of taldcft piewure, vmULvxe,aid my equate to 111-? 1. Re to E C ` l Cl ` MM For designing at elu ted uojft constdt the a. pct FXtRC Approval GuidwVOOFNAV. EE +� o II 7 k �NIII�I I u�lllllll I�,I IIII I �Illlllkll Ilq�lll III + t II IIII 111111 �I����II�I III II, IIIII,�I�I IIIA II IIII�IM��IINIf I I�I�� ,IIIA (IIII IIII IIIIII ��III�, � III IIIIIII,��I��I ILII I��I ll:l I,II�I a �u u'r I',��!►�'� II III II III DRUITC HD �a�il�li,IINI VIII Illi lu�lll�ll INIIIU$ I�II�I ���, ii�NlC�i� 1�j11��� IIS Ip„ IIIIIIII�III IIIIII IIII IIIA,#VIII I�IIIII, ra EE TAKE FOR AVCHANKAILY ATTACM SYSWM Vahm Os) TRW Pattern PA*M 7W DRIII-TFC XHD 2 W harbed 11" into the 18" ox, 12" .c. 700 URS TEC 111) (15 2" douw badw 1"into the 1 "'O, . .UnKOR-9 Concretc 900 IDI.-TFC" eke 2 YW WW 1ID p" into the dKk War, 12w o L 900 1DRIII-TEC- Spike 2" douW barbed p„ into die deck tE" o c, 12"oc 900 I.r.-°r °e :k V doubt MW j" i 18"ox, jr oc 50 DRIII.d 1,.5) 2 D V4' the forat 18' o.c» 6" o c. uotwot tnmdxdng 450 1D I11LAEpC ($.5) 2"doublebaAied 4" h f t " o c, 22 ga. standard lom 5 fi U}} �C- Iii L, 1 ) "' fi�gs XHD $ through ^� " th h � fo a p 12" o.c. taw o.c. 150 I)RILL-TFC HD (q14) 2" double barbed m @" through 6i 6 ox, (15) XHD lumdatift 50 DRUITC C D (#15) 2" double babed V through the form 12" ac Concrete, 24 gL standad if 550 BRIE,-TEC' IID (1) 2 " MID 3/4" dMigh the fmm 12" ot, 6" o.c. 350 1D IU,-TFC- HD (14) 2" double b " through the fom 12" ox, GYPSUM Concrete 00 1.DR]I -T.EC- Kdrner Screw 2" x into 1112" the1,B'o q ry p� ilkt�... 9 1Dggyyp k 2 ". badoed XHD 11/2" into di 12'" o c, 6" ox NO t)ti}tIU, TFC Screw,$� 2" t 12"" kdo, k 12" Ox, Wood Filter 2" 1 1 1111111111 1 Pand 300 tDRIU. "3 C" potyrner smW 2 " bathed MID 11/2- into tip deck 12" ox, 6" n c. is to � %& squ foot ( t ift p� re t,b :. �e may ate to M I-% yyyy. gg�y�g�lt p#�� efer o cment Mmal Guide, NOM For destpung at elevated uphft please emsult the curtmt FMRC AplmW GwdL,/ROOFNAV th 1XISIS "I'll" IEIZMM m I Ki xIrgk+ # f and con t, h > t. tt 1 1 t 1 t¢ N Q . 1 1 ¢ t , fan 1 t a i Size is IWO appmved .ru ,..... A n n i > 1 w LRF -M (For ring both amabram & j ) only)UW-0 (For Wiftering mmbr=e 04BMO (for adhering - Notc - Adhesive ribbons must be applied at awidth of V (25 mat). EP Membrane attached in the lap with screws and plates, Part m Executon RE Im Im M Mechanically attached heat-wdded theenrophisfic sheet mof Mendicant s 88. iatd RIC raernbraries we not to with PmGuard* I" and EverGuard Uttme,materials, DO Wff mix EverGuard" with menthmnes, flashinp, and flashing accessartes together in the sante roofing sglcrn. 1.03 RepWary R is And Pee4ob Confetvm , Conform to At applicable building and Jurisdictional including too( assembly wand uplift and fi napomments and slope limitations. GAF recommends at least " ( .d ) per foot s8 with grading and placement of drainagr lets. Fcdow)uu local jurisdiction miumanents for disposing 4 used expiredor adl ` anti and otheT woducts subted to disposal regulations, C potential problems in maftng applivations, as well as tial "ti that may be detrimental tot fart : ancP of the be lrl prigs to raf tlae i "gar. l rlislr a non-ra rr ittc tlrn arctri rr itr i dl as will involve the mofyst�i laterf Vis» and dw manufacturer's representative. 8),11 following am cornmon iterns of discussion t a pre -job conference, 1. Rod deck conditions, 2, Flashing and expansionjoint details, Insurance underwriters or bufliting code requirements, . unusual projectditi . Protection of the building, building occupants, and contents during and after aWication, b. Application techniques, Coordination scheduling ai that will be working the prolem & Designation by the zg contractor of a qualified person, resporisible for quality control. 11r8s person, sliould be on itre Direct full time during aliplication of the root sistent, and should not be rephicedwitheut the Vproval of GAF. . Sclualtifing of material slulanents, material storage, and muftop `rig. 10. Sulintittals of materials, drawinA and project doctunents, FM 104 Ddhwy, SW2M And Pretftlm . Deliver products to sitein original containers with wals unbrolkien and labeled with manrafactirreW name, product ligand name, B ShMr - e rriatr rials in gather-prt►tcclex8 environment, clear ofthe ground and moisture, in accordance with GAF instructions. Store all aithesives, coatings, aW sealanWcaullm to Imitcot it= from rig, Fnimi material wrist be discarded and replaced. Property f all liquid makrial contaftess after Outside gotage of vorifing materials: L All materials stomil outside must be raised above ground or roof level on pallets and covered with a tarpaulin or other stundd be property gored and weighted to avoid weather and wind dxnar- 2, Factory-tr6talled plastic wrapping is not designed as pvtoralve covering for insulation twwrials and should be reanived. Use venting and protection from weather and moisture. 3. Cover and proted materials at the end of each days work, 4, Do not remove any pro"ve tarpaudins until imnv&a* before material will be histalled. Fmrenie heat or cold conditions tuay require Veda[ storage requirenwrits, Refereum product data " for product storage terjuvernents, materials prior to and during installation, E, Do NOT use matertals that are wet or damaged to the extent insulaitim that has bem wet is considered damaged, even if later dried out, Remove all damaged materials from the lob site. F, When staging materials on the mof during application, ensure the deck and struiture are not temporan� overloaded by the weight of construction materials. c 1.05 EnvkWmental k Do riot apply roofing materials during inderrum, or W quantities grater than can be weatheiptooled during the same day, C Be aware that lugh or gusting winds make the installation of some materials more difficult, 0, Material installation during high ambient wroperature arWor humidity l els [tocally show 9rF (320C) xWor retafiw butuidityl can result in poor histallantinquality due to aMmution on lre ff xTribrane surface or excessively fast adhedve drying riats in hK dry .fits not install materials', vdien ' sere, in y f n, ist the red deck or whOrate tea*inch the niaterials are toy afilibed. R. Maftat installation during of law ambient u qVically below OF WC), can result in poor nardlation quality. To avoid these problem L.Store amessorymateiials in avrimningbox, 72. ti as soon as possible after removal frorn wanning box J. Allow adhesives to jivoperly 4, AdhLst welder settings to ensuce pAVer welds for applicable arnlawt conditions, 1.06 VwJMg Eaviromnent Work should only begin when the contractorhas deckW to W her 'on that all le as specifted, and that the ountraclor can code requirements. ii.Ihe contrActor should ordy begin mofing work when tine substrates ham been prepared as necessary, y to acoelit the roofing mWerials, hisudled as specified. C, ['r vide a safe wanting envirourneut, including, but not limited to, adequate fall protection, restriction of unauthorized aoces to area,the wA, and protection ofthe building and its occMiaras. 0. Safe work linicuom should be followed,including, but not limited to, keelong wh in good operafing order providing adequate tiiation of d datiy housekeeping to movive delins and other hanxd& See section 107for further 'lbs on safety. E. tine building, contents, surrounding area, building occupants, and contractor pers. onnel during work. t ate all work operrajons with the building owner building occupants so that adequate tart .°bora, as ncomsary, is providedand disruptionto normal builifing opmMons is ruin t ` P. Where heaar wheeled or Warr trafflic mw the partially caurpteled roofing is unavoidable, plank pays , set over a minlinum thidness of rigidboard insulation to pnitect flee installed G. Prwde "m water cut -a% and tie-ins at the end of each wridalay. Removr all ternMrary work at the beginning of the randw�rkday, R, Own tearing off an costing neem e, [but rernoval to the va that will be cornpletely rerooled that, day with the new ng "em. 1, if comfitions are uncovered or created that vx)uld be debtuendal to the proper ainduct of Vwfied wk immediately notify the building owner and CAFof these conditions for ounsuftation on acceltable treatatents, EE 1.07 Safety CMUMeratim And WwWrip r A. fverGGuatd (Smooth ` orced) I'lienuoplastic Potyrilefin la 8 Pace -Back (FB) Ibernioplastic Polytilefin hleruhtane C EverGuard Extreme Smooth Reinforced and fleece -Back Tl r l nTPO Membranes. Tlr n destg to provide high solar reflectance and ex .qty high LIV and t resistaw, D. herGuard" PVC (Srnooth Reinforced) Therinoplastic Mernbrane, E. -Ruck Therimplastic M can be used with EverGuard,* TPO mrstibrane for flashing in the same thickness as the field tuenibraine B, The use of EverGuard ExtremOVO flashirigs is moverl on characteristics, contact GAF Technical Services before Ampung to Wil dillerent-coloted TPO membranes with white awridiam or flashings, 1) EverGi TPO and PVC F "To A. Ewr(ketrilO prefornied flashing carie must be of the mme type as the roofing metribrane, 8, For a full listing and descriptionsof tate law R and uard Exe flashing Accessories, the rude uct fear the specific you are working with. C EverGuard ExtrumO TPo flashing accessories is reiltated A ne system D, All EverGuarde accessoriesm indoors and protectid from tura and extreme temperatures,specific instructions; on packaging for findier details, e and Oates, and flashing fasteners and fteardnabon ban, Refer to the Imlation Attachau" T" and the, appropriate, Mombrarw Attachment T*e in this Manual for the correct Mv, length, mid K 14 fasterters that are suitable for the deck type, and ensure the de& is of the required thickness and cwidjtl�n to ensure reliable installation mid liciformance. IC Fasteners used in flashings should be dictated by the sukmte, ractubranes and insulation. Bonifing Adhesive for PVC c. Ever Cruard" TPO Low VOC Braiding Adhesive, for 1K 2, water a. EverGuardO WR 181 Water-based : dhe ' for smonth-back TPO mernbranes,'I'l l FB membranes, and PVC FB menibraum . luard Rise F ..1. F adheshv designed for insulation attachment arty. , Wants t, Ever6tiardO 2 -Part, a Pourable Sealant for use in aut (pitch) v. EE 2. TO " r FlaW t ufk Grailc, a white,solvent-based synthetic elastaineric cedant for use nd termination standess steel darops, drain ,acrd other am between the substrain anil membrane, This includes . } where at the toe edge of flashings where constant jwessure is applied on de motmembrane. . Everi(vuard," T P t Cut F.dte Sealant, C rs F uar€f °F O Prix 2.06 Traffic Protection EverGuarP TPO walkway Gaffs and KC walkway , 1lieselection o(insulation type, thickness, configuration is the tesponsibility of the architect, enginw, owner, or mot consultant. GAF moves the right to accept or reject any roof insulation as an accelitable substrate for GAF rod swans, GAF Pri uard' insulations must be used in m6fing systerns to be guarameed by WF R, ,Guard" foam insulationsof the types listed able. The actual minimthiduress of insulation will depend on flute, `n , Refer to spedfic Product, Data, for further information. Board size can be 4" x 4° or Tx 11" (1.2 in x 1.2 rrr or 1.2 ru x 2.4 rrr) panels for mechanical atachrrrent„ d 4' ' 0.2 in a 1.2 in) for adhered aftAmient and tapered Panel& 1. ward' Polyeocyanurate Insulation with Rt facer trasaing or exceeding the , tura is for AI l Cl 2R9 [ruin. 16 psi (l.t ) contlimive strength]. 2, FhafyGuarrr Extruded Polystyrene Insulafton awting or exceeding the mVitements for ASW C578, Type t t nomirW 1.5 42 cubic ) densifty and ounimurn 15 psi (1.0 Kg/an) corolvessive strength, 5, rtarrl F Prr lnsttl vdr f` ru " ` rg firer is ferr { It rt rirrat 1.5,rurtd f42 #c crrr) .ty arrd rrri�rirrrurn f5psi (l,ti p "e, C. The following itional irbulatlow are =eptable for use in rocifing."enis ' to be guaranteed by p " Perfite FinergyGuarC Perfite Root Insulation Board (AS CAVS UI -I -535b, Qw 0 Blue Bulge lli h Dersity F" and Roof Insulation Pohisocyanurate (ASIM C12 FS fill -1-972. Clams t) EnffgYGuard' Pol . Insulation, as above DrergyGuard` Tapeird Polyiso Insulation (ASTM FS HH -1-1372, ASTM GenjS IM -1-1912, 3) ftwW"ard- Composite Board ftlyhm 1 Tweednsdation hwrGuaw site Board IU=ktkM ostle Boanh am numuladured in various arms with efther a pedite or wood fiber trig, heYer QMW Your nearest CAF sales office for ad(Iftional information. . 08 High Traffic Applications A. ErWVGu;uC town insulation of the following 4W in a nunktrum 1" (25 mm) dA&m& Howmw, actual thicknas will be dent rare flute spacing, Board size cart be 4'x 4' or 4'x S' 0.2 rrr x 1.2 rrr or 1.'2 rn x 14 m) telsfor mechanical t, and ' x 4' (1.2 rra x 1.2 ) 'or adherl t and tapered parals, 1..BiergyGuarC PolvWxymurse Insulation with facer meeting r exceeft the requiremerits for ASTM C1` 289, , nritr. 25 psi (1.11 kg/an) crarrpreWi strengti). 2 F ward"' FXtruded PohvYmne Insulation ( ) meeting orexceeilingthe rialifirementsforAMM D578, , 4"` [mina 25 psi (1.8 lrgla rrr) compressive st"gth. 5. KIuaM- FNpanded 161firsulation (FY) with plastic facer inecting or exceeding the mquirianents for , TYPe IX firin. 25 psi 0.8 kg/ comp strength]. 2.Cover/Re-mver Boards Fnerard' Pedite Insulation, minimum W (1.3 ), ASTM C72S. S. III. Ride S High Density Fibedward Rod Insulation, nu ' a 16" 03 mm), MIN C -2(k Claris E C. F ' F arBoard of the following Board six can be 4' 4'or4'x '(1.2rrrx11mor1.2m,x 2A rrr) pairels for medlianical attachment and 4'x 4' or 4'x & (1.2 rrr x 1.2 or or 1.2 rrr x 2.4 m) for adhered attachment and tapered sTAems, except for fan -fold r board, vditch cornes, 1n 2' (0.6 m) x 4' (11 m) sections with a Vii' (15.2 m) total length. a ardfiurate Re-cover requirementsmeeting or g 289 firdiL t6 psi 2. FneigyGuanp` %, (95 min) XPS Fan -fold Re-cover with islastic facer meeting or exceeding dre requirements for ASIM,D578, rAv IV [min, 25 psi 1 .8 ligirm) COMP,ewve Strength], 3- FnergyGuard- Vz" (13 mni) EMS Re -covet Board meeting Meiling the 25 psi (IS kg/cm) owilnssive strength], jilastic later meeting or exceetfing the requirements for ASTAI D,578, 1*, 11 (Inum 15 Psi (110 KBICTIO coinpreww D SFCUROW Red Board WCUROCK's Roof Board ii avadable ill 1/4- (63 tran), afive hartier, an overlay board, or as a m -rover board, Boards (ASTM CI 177) 2.11 Slip SheeVVrotection Layer C. VersashieW Shcrr'' un t. 2.12 Odw Accessories 1, Wood Naders-Trailers must be #2 or better lint . Do NOT altic or ted lumber. 2. Roofing Faits: Galvanized or non-fermus Mie and size as required to wait application. 3. Tem ant: Polluethane f t or similar as re€puir l to ght sealing of roofin& 4. Air/Vapor Barrier Pottindene sherting, Taira, 6 miL for TPO only, 5. Fire Barrier Silicone -treated filer f rn min. #j-' (0.3 Tarn) thick (pWm board or rtenswe- Prime), • 3.01 Site CA"tiom A, "in veribrabou ffiat the building stnicture can =murnodate die added vaglit of the new roofing "em B, Coulnut the adequacy of the new roofing sysuan to provide 1xvfive slope to draim Eliminate ponding areas by the additiort of drainage locations or by pvkhrig addkional latch to the rodsurfact or to sWicatkin tutportant for the liklihisixt that deterioration or WM L Protect Wiling surfaces against darriage mid conwirination F Whm work trust, confinue over omfibaed mof area, protect frDeck preparafion is the We ")misitufity of die budding omwr or, railing contractor All, &-feet-* in the rod " or H. In addition, for FvvrGuaid bareroe.* TM Roof S)�s, buildings greater' than IOW (30.5 m) in height must have a noninium 3' (011 in) paraW wall to be, eligible for an extended IMO Diamond Pledge- 25, or i0 -year paranw, A separate counter flashing or cap flashmi; k; required; exposed tennination bars am not acceptable. 3.02 ftqmmfioad T A. Remove all ousting roofing usairsials to the roof deddn& including in edgialp, drain pipe be* and ttdi , and t m surfacesof ail astAtalt and adhesive contaminants, bon and by fastener pull-out testing by n4 fagener manufacturer. deteriorated deciting. 1, uard FxtmmO TPO ItC *LTii ' , air r l wall n than 10 a total wall area can be open during a wind stoop, including) openingdue to. ° Refer o FactoryMutual Loss nfi �1- I-? for iic installation" f+ � motswith lie openings, U1 3.04 Wood Nailer Instaffathm A. Acceptable Materfid VP' (88mro) minimum. Aid blocking, 250 lb. per & (550 kg) load alqgied in any direction. I Drdl-Te III) screws IW (460 non) ox, adachment thread embethrmit. or thread perietration, 3, Wood nailers attached to gpvuj concrete, cellular concrete, and cententhousviod fiber must be fastened 12" (305 mm) ox, through the nailer into the substrate with suhstrate- 4. Three anchors per length o(wood nailer nunimurn, kichar to resist 250 lbper k (550 kg) load applied in any direction, I - DrdI-Tec7 fU)wc 18" (460 nun) ox, attachment to strucu". word, meet de& Min. thread ernbedinent. 2, Dfill-Tec- spikes or 111) savvs 18' (460 non) oc. attachment to concrete decks. Mim V (25 nun) xhank or thread penetration. 3. Wood nailers attached to fflisum concrete, cellular concrete, o.c., through the nailer into the, sAxtrate with substrate - 4, 11tree anchm per length of wood nader minimum, D, Shim Material Seecure simultaneously vAth overlying solid wood nailer. I - Shim matemil mug be continuous, Do NoT use 3.05 Gypwm BoaM I A. General i. Gypstun fire barner board must Morally be installed when erred by design prolessional or code authority to addrem code or val requirentents. Em I . Butt g)jistun boards topther with a'/4" (6 3 rural aumn space between adjouting bwr& Fit Clism boards around penetratiams and perimeter with a V47 (6 3 mm) trwimurn sliace between board and penetration. I InsWI ppsurn boards in pieces a minimum of 2'x2' (frits nG a 610 mm) in sig, 3, Gypsurn bomds installed over steel "ng most haw boards placed dir l r to deckt flim with edp over flat surface for beating d. Do NOT u za boarris that are wet, , or must be discarded. I mutation boards that am broken, era, or must irrwtalled I « . d is first rcruowd and dixanled. 5. Renwe and replace *pm boards that becorne wet or dantaged after 6, Install no tuore *psutn board than can be proliedy covered by the end of each daywith torifing enembrane. i, Mechanical Attachment a. Use appmfina* type and length of Drill—Tec— fastener for structural deck type. See Insulation t Table in this Nianual. b. Install required number of fasteaxers per board size, acrd t}" of roofing systern installed, Refer to the construction details at the end of this Manual. c. "!prig is required fear concreird , and may be required for concrete and cernentitunt; wood decks.fiber & Install fastener so as to finely imbed the !elate to the insulation surface without o . -dr virsgn 3.06 Air/VVwar . (kneral 1. Aichapor retartler components must typically be installed when required by desip prolessional to a*m internal building air fisure or hunfiddy conditions, a. On all air -porous, docks — with opetfings in the AWIs or arm dfte4 below the red deck that exceeds 10% of the total wall arm b. When the internal pressuri7umin of the building is in c. Wben the Wilding height exceeds 50 & (15,2 ni) d. fluddings with large openings and overhangs must be evaluated for air retarders or the installation of half sheets of toof membrane. t Refer to Factory Mutual [Am Prevention DalaSheets 1-28 and 1-29 for specific imullation pro"res; for all roofs f, Conditions where posift internal pressure is applied uddenly, as in the case of aircraft hangers or ifistrubution centers, rnay cause failure of the roofing systent due to pressure impact. B. Alildicadon 1. Install the airA-Apor rdardercomponents loose- liedto the deck or fire barriter board so that wrinkles =ddes am nor formed, if minimum 6 mil polyethylene is used, overlap a nornomin of 6" (152 mia�. 11 Overfall air/vapor retarder components per applicable 1 Seal perimeter and penctration areas with foam sealant placed over the nailer atril c(Atting the exterior face of the nailer liv r Is nun), NOTE "OJ that the pepper 1 cl� closed, or open) d�lh lac,), improper ssibcation ca failure caused by "grang to lower loads than acurallIr etst for the building in question. 3.07 Slip Sheet f A. (kneval 1, Install rrl matt protection layer betwmit tlac roofing inembrarte and the sit in accordaice with the Design Table at the firan of this Manual, >. Instill polymat protection layer l ied over sultstrate surface so that wrinkles and buckles am not, fortnet 3. € vedap polymat protection layer a minimum of " (152 nun) for side and end hips A. CkwxTA loose- appliedr6'7;'MM19WM7*' FWA77"i layer is 11 when required by design professional or code authority to in accordance with the Design Table at the front of this formed buddes are not b- Overlap GAF Versa.ShieldO Wo' prittection layer a mininturn of 2- (51 x end 1aW c, GAF ire x " 'ell "on layer shotdd be mstalled perpendicular to the direction of the TPO cnenifirane, 1 (IAF Fi t- Fire Barrier ag is installed at an aWication rate of one gallonper 111 sq. It (93 s . in) via hh, or roller. The substrate runt be clean, dry, and fire of foreign matter. En .0 A l 1. Refer to section 2.11 of this Manual lorspecific GAF requirements on r . / bo 1 Install intsalation board and board as requiredin accordance with the Design Tables beginning on Page 15.. 3. The use of extruded or oqwxkd polystyrene insulation is limited in Pi: roofing systems to use under a fleece-baclr membrane or with an approved slip sheet. .placertent 1, Butt insulation r with a 1/4" (6 3 cram) nocumurn space beevern adjoining boanK Fit institution boards around penetrations and perinieter with a 1/4" (6.3 gym) n�inrurn boardand penetation, Do taut kap � into place, 2. Install insulation boards in, Pim a minimurn of 2" 2' (10 mm, x 610 grit) in size,Even, piew must be property secomil to the substrate. 3. Insulation boards installed in multiple layers., must have the joints limm boards staggered in all directions a minimum of fr" 052 nun) a la 4. Insulation led ow steel decking must have boards placed perpendicular to deck flutes with eilges mer flute surface for licamig suWrt. 5. Install tapered insuWon to linmric a sump area a 'rauninurn of 36"x 36" (914 nun z 914 r a) where applicable, 6. Do NOT install insulation boards thafi are wet, warped, or bucM4 On mutst be discarded"Insulation that am broken, or crushed must not be installed unless the damaged area is first rernoved and diwarded. 7, Remove and replace insulafion boards that becorne wet or damaged air installation. Install no in= insulation than can be properly covered by dee end of each day pith roofing membrane, 9. blas, XPS, or polyiso insulation be used to tilt in flutes of steel deddrig *im used in conjunction with a corer board, 1. Mechanical attachment of insulation a. Use appropriate tib and length of Dtill-Tec-fastener for structural the Insulation t Table at the from of this Manual, b, Install required number of fasteners per insulation board size, and type of rooling systion installed. . drilling; is miluireil for concrete may, be required for gypsurn concrete and cenientihom wood fiber d.install fawner as to, hinfly unlied the plate to the insulation surface without over -driving, e. t% fastater of correct length as mpored by the Insulation t Table. The use of any fastem greater than " (203 Tran) in length must, be pre - approved by tM i°echnjcW Wires. 13. Foam iWhesive Substrates must be trrVected mid, aox*, by the contractor as swWile to receive and N" 104 Membrane materials, Substrate Surface Prepamdon t, Prqvre sulistrate affues thoroughly Mot to apoication of new molingrn ats. Ibisis particularly, important for re-cover mid ung aWicafions, 2, Preparation inclurK butis not limited to, nemoval of existing flashinA m0awnent of existing ung mataials, mal of low aggregate, VWI of abandonedetfuiprnentandpenetrations, m0acement of damaged etc. 3 a smooth,and dry Weatate miturnizes the likelihood Haat underlying deficiencim will cam true deterioration or eixm failure of the new mofing'systam 1t. Plaoftem, 1. Place membrane so that wrinides and buckles am to hirened. Resnove any wrilikks or bu ides tion, the shed prior to Permanent, tv Roofmembrane must be Wedharucaffy fastened after it is rolled out, followed by !ding to adjarentsiteets, 1 Full -width rolls must be installed in the field of the 3, Half—width rolls rncrst be installed in the perimeter region of the red, Width of the YW penwiff region must be determinedin accirdance with the perimeter Hallf" Sheet Table € n page 24 of this Manual, Overlap mof membane a minim of 6" (1 52 num) for side laps ofiverfianiA, attached systerm, and a minimum 'num of " (76 mm) for end LVs. MenibraI ate provided with lap linesalon the side 146; the inside fine is W !sd 4stem ovedaps, which am 6" (132 nun) for T145 membrarrs. For PVC membranes, s, tl solid line (overlap fine) is marfed on the top Ply V (f 27 nun) horn the slieet edI fiuitener lure is a nominal 2' (3 Harr►) from the shed edge, and "!t" is placed bewen the sheet edge and the fid seam overlap Jim oath Vwmg eyery 6" 0 52 mm), TPO fxfter staring ruarks should reseftible a "pyramid" 3.. Best sras is g, ptadke is to install membrane so Haat the laps tura across the m slope laj4W turd drainage points, on metal Viking, install sheets perpendicular to deck direction o that fast . , will penetrate the top flanges and no Ste flutes„ however, there r ll be linutetl areas of alae roof (i.e., perimeter re this is not practual, If the derk is running offlnite the slope of the roof (flutes running horizontally), then the mentlitane should run ridge-to- gutter l _ , to ensure poW fastening to dre top flauggs of the deck, 6. All exjxzod slicet owners must be munded a rntrurraum of I" (2 rant). 7. Overlap mof membrane a rnfrsirro of 3°" (76 ) for end laps of EwrGuardO PVC and TPO rrsernb . for EverGuard* fly -back membranes .are made by butting Aacentsheets and heat welding an g' (203 ) Everts reinfinced mernbrane flashing !r mer the joints. Rw PVC inembranes, cut a g' (203 n) wide Hashing strip out of snaxith PW, membrane of°the ; a thickness as the field sliceL Roof membrane must be mechanically fastened in the side lag am to the tod deck with fzteners and platm of a tlpe mid Vacing splooproue to the and as required by the Membrane, Madiment Tables in dus Manual. 2, lbe metal plates must be placed vadon 1/4" - (6 unn x IS ) of the nb Plates must not be placed closer 1/4" (6 rum) to the membrane edge. 3. Fasteners.must be installed to adoeve adothe errs est defiffi. histall fasteners,me l to the do* without lean or tilt. Do not over- or under -drive f m— . in die comer xm additional fasteners will also be lel tla li tlT,� "3110 aal[ ala rri e galls to f t grid f 3 rr) w'de reiralairc d ohninelist- rill additional rare ap in comor iwlya fralf slmay l laid t x, `n die fasteners as the l ,nder z_ likdanically aftadi ntentbrane with screws and plates, to the roddeck at locations o(dec3a slope changes in eat oft" in 12" (25 min in 305 Warn). fa. Wletribram may be heat welded to EveriGuarde flanges, a. Ateudirane most be Wired to the mof deck, within " (152 traria) of the base of walls and carry, at the 'pevurreter, and all penetrations with drill-' bc� Fagavers of a type and spacing„ in accordance with err -lap alladwxnt requirements, with a 12`° (305 Warn) o"c. rtes " nu as spacm& h. Alternatively, menthcute rosy be Oncortoij venicalh, 3" rap llWs curbs and secured to the watVcurh atistrate within 2" (t ) of the plane ofthe nxt. Use ' l- ecm Fasteners and invertedterimmifion liar of type and spray in accordance with ire -lap attachment rtquire arms, with a 12" (305 min) o.c, maxinium spacm& Vertical attachment with seam plates and las be This alternative detail, including inati o is required to he used for pressunl bufl&W Refer to detail dravAngs at the aid of dais Manual for specific application methods, 7. Install fasteners so Haat the plate is dram down tightly to the mernbrane surface. Property Installed fa...rs will not allow die plateAminadon liar in rn (u , but will not can* Wrinlifirig of die membrane (overdriving), D. MunbraireSurface IWparationfor Seaming 1. Alembrane must be dean of dirt and contaminants, and free from dew, rain, and other soum Imme", to x ain Js tied mildlyimmedi&ly after placement and securing of the I Membrane that has been qwW kr move than 12 hours or has become containinated will reipure additional cleaning medW& 3, Light Contannnation--litembrane that has been cqxwd overnight up to a few days to airbome debrts� foot tW or dew or light preciftitation can usually be cleaned with a white cloth moistened with EverCuard"i'TPO Cleaner or MEK for PVC. Be sure to wait for solvent to flasb off prior to welding, t Dirt -Based Contammation—Membrarte that is dirt encrusted will require the use of a low -residue cleaner, is Formula W, and a rearowe the dirt This must be followed by dearting with awhite cloth moistetuxt with EvetGuarrill TIPO Cleaner orAIEK tot 11K Be sure to vwt for solvent to flash offff ptiorto welding. 0 X x x x x , x fleece-hadsurface of the fintshet! md, we the following procedure to remove the adimitc: aCarefully scralie off the adhesive without nVutung the b, After reminal of the adhestve� cover the affected area with eidw BwGuard' sn"- or fleece -back c, Weld the smoodr-back edges per speafication, or strip in the min) rdnilbrved smootIt-bacir membrane half on the sheet and half on the roof x laps for FwxGwWIO flecce-likk membranes am made by butung adjacent sheets and beat welding an 8" (203 min) wide membrane of the same thickness as the field sheet, d. Finish off the proom by adtling EverGuarile' TM Cut Edge Sealant as needed. . Field Seanong 1.. Fabricate field scams ansing a current-generanon automatic hot-air welding machine and a lit„ voltage- rtrolled generator ria" 'morn. In addition, fabricate detail seams, with automated hot-air welders where possible. Outdated welding equipment and inadequate or fluctuating electrical power are the most common causes of poor seam welds. M the beginning of ` (i.e., morning _ d irte iat acrd following a significant change hi weather (,e"„ air re, wind cloud ver), 4. n m together. All wads sun be continuous, without voids or parmil imlik, Wel must be five of bums and scorch mark 5. Weld vadth must be o minumim 2( ) to a imuminim 1.5" mm) in th for t atic hi welding ( c `der) for standard GAF guanntees. A tdinE trf d." ) .s to r f txf t (Florida) and SCti in fieldseams of all IM rkPrCk, sht rtrt t r drttG elder in the 6. Allcut ut of TPO reinforced hr" mast be seated with E)K-rGuardt TPO Cut Edge Want. Catraoin and inom l6ft(O Awn, may result in dekctiv�war�­vktds. 2, Setting theyed of the welder too fast can also pw- potential pr Im with the ability of the %*raw to maintain control of the welder. 11ns is particularly true in to monitor thel 5- (�2 ,8 nim) mininimn weld and enm that critical T -joint area have been correctly cw2sed, 4. operator must keep in mind the relationship between re and robotic welding x in order to achieve a Vec weld. 5. Increasing the 5peed of the toliotic Wder cart also compromise the appearance of a non -bonded sMem, 3.12 H=hing (aftHatim Refer to the constniction details at the end of this Manual, whidi depid sink requimitents for MAcally encountered conditions, Install flashing materials as shown in the coristruction details. A. General to EllaKsh ail ter, curb, ati iti with E t►a co rn c° log and flashing aotessarioess appruirnate to the site condition, ® All u e flashing comers must be reinforced with pre -formed comers or tion-teinferced 3, All flashing membranes and accessories are to be heat welited to ach` a rnirt' n " (t ) vAtle its rr a hand wider, Vhen using robotic welders, refer to Section 3.11 E. . All cut edges of mWwred TPO must be sealed voth Ew-WAtardO 1710 CW Edge �Wmitr 5� When using bonding adhesive, be sure to use adhesive c to MMlbrWW and ambient weather condmorts, 6. Minimum flashing height is 9" ("?ta ahoy). R3 T The, maximum ifisiarne from the. wall that horizontal mechanical attadynent is hroalled is 6- (152 nurt). When ZZY' 6" 0 52 mm), nuive die attachment to die S. Installation of EvexGuad* WC flashing membrane over a0alt-based stibstrates must have a slip sheet or approved insulation botints, metal, wood, etc., water die Mr tiasmug menthrane. 4W, thichiess, and color as the roofing membrane, 10, For granulated modified bitumen flashings, a separanirsheet must be kx for dry -hung flashingi. barrierIn adhered q0tcations, a be installed, B. , Coaled Metal Flashing x providedInserts, and aimen ol' rod edging, base flashing, and cWin& rowt be overlapped or pieces to arate .1, confiititmi flange condition, and W be stfiliiiedin using,6" (152 non) r 5. BlerCumd'ecoated metal base flashings most be provided with min. 4" 0 02,rum) Aide flanges screw4 to -*uxt naders, FAw(oe%rd'&vpaW metal base flashinp must be funned with a 1' (25 mm) Card, k Provide a �b- (13 mm) hern for all exposed metal edges to Provide corrosion Potection and edge teinfiavement for trujitoved durability. x edges whenever possible to prevent waring of the mofing and flashing membranes at the flange edge. x metal flahings are attached to wood adherednailets or WxTMw mechanically, attached to the mor deck or to the wall or curb su&qr*,, in aoLvdance with construction detail reilunenxmts 7 iL abo" that tell 1;�o e;r and uglitly 3. Application of bordng adhesm. 7. Porous substrates nuy require double aMication of or cap flashing is requimil; exposed tertnination ham am not 9. Alternatively, the EverfyuardO Freedom" System can be used for flasifinp, Consult the EverGuare, freedom- Ymual for M E, Low Reirdorced MmAirane Flashing MARUNWIlt, used, Fxposed teffnination bars are not xceptable. 2. Careftd� position the x smooth reinforced and buddes, i. All laps in EvaGuarr smooth reinforced flashing membrane must be heat welded in aamilance with hear Welding guidelines 4. Maximum flashing h-joit, is 24" (610 min) unless incremental attachment is, r F. Non-reinfiaced Membrane Flashing t. Non-reinkitred mernbrane can be used as a field -fabricated 1miettatior0eifforcement flashing ly where pre-tortned corrm and lid boots cannot be limperly installed . Penetration flashingconsmided ofnon-reinforced ruernlara t atc* installed in t o sections, a vertical piece haat extends up the penetrafion and a horizontal pim haat extends onto the roofingas b ae, The tm pieces am ovedappW atid heat welded torther 5- The non -reinforced ical ineridam ne flashing may be adher(KI to the PeRetration Surlaw. Refer tosechon 3,12 C fear application tom . d. Finish the with n the Pipe and the meml clarriping band, and TOPCOAr FlexSeal Caulk Grade. 5, joisat Patclo a. T -joint patifies am to be a nsinanaeasaa d" (102 turn) in sig ad made of non-reinfinced material. "fa must be hot-air wided am the T -joint at the intersection of the three piecos of reinfreced inernbane, Dining i most be taken to "`c -ars"" tit rid aaa ala at the three 1 mernbram that match the tuernbrane leant used in the field of the mof am accettablefor T -joints. c. T -joint paWics to be maile fininnon-nanforced " non -reinforced u ae , or non-Mainwed PVC, as applicable, d. T - joint patches are required on 60 and 80 not TPO and t nail PVC oratg. LE ff. Parapet and Building Walls I. There am 3 options for flashing parafiet and building Its adhered membrane flashings„ meed fl ,shin ,s, and l h flashing. , Set= membrane flashing„ at the tarp edge with a termination bar. Apphy"t`OKOAi FlexSeal Caulk GrA caulking Wwew the l surface and membrane flasidag underneath all terounation bats. F.\Ioed termination ban must be rnechanicalh, f " ( i5 mm) o c.; termination bars that are counter flashed must be fastened 12" t 15 o.c. 3. Raaf vnernbrane most be mechankally abe along the base of walls that are Batted with metubrane flashing with sam d plaWterafination Isar at fastener ng in accordance with in -lap attachment requirentents,,with a it ( 15 ) ra.c M `rn r : in , 4. Metal counter flashings, with fully adlieted or dry hung membrane wan flashings are requfted on 20 -year "I or longer. Mwy am (lot required for guarantees of Im than 20 years—) All terinination bars, either exposed or covered, must be sealed With TOPCOAr flexSeA Caulk in Giade caulking. rat coated mend that, is inectianically r to the wwall mid integrated as part of section for other deewl o0ons, * " (f11 rr) — iorteApplied Flasfrzn * 5V (1,3rn)-- Adhered Flashing 7. Ak-W cap flashings toust have continuous cleats or be face-fastined 12" (30.5 imn) o,c. on both the inside ar-A ouWde, of dre walls, WWAaMe Gold *jAWu board is NOT to be used as a Areas! acconling to the mantiactueff. 9Use fire -treated 0v%u4'mW for wans only if parapet covered with an approved *Won board for (fulb� ailhenul or EverfyuarP Fteedote materials L Round and Square li Penetrations 1. Four options are available for pmetration Bas in s, I'licie are Wil pals bares split pipe boots; square tube and field fabrication with unsupported membrane and L , All flashings require the installation of a sirdnlesswel draw,bard around the top of dr. flashln sea] the R eel and bmW with i)f' ,0A Flex"" Caulk Grade caulking, 3. Roof membrane must be, amcgh, attached at the base of each penetradon with screws and plates a maximum um of 12" (305 mm) o.e , with a minimum of four f ers perpenetration, a Irregularly Sha* M LE I . FwGuare OMW Metal Mof edge scuppers must bepixivided with a min. 4" (102 rum) wide flange naded,to t comersv4th coutinum clips in accordance with the graiv! stop asswtbh� I FverGuard* mated awlal wall scuppers mmq be provided with 4" (102 nun) side flanges, with a"tional comer pieces pop-rhoW to the flanges to create a continuous flange- All flange y t 3, Install wit scuppers over the wof and flashing oiwd�rjuc and secure to the roof deckAvall with Drill -Tec- fastatee 6" 4All corners must be ididorced vAth 5. Strip in scupper voith flasithig membrane target sheet 6. Alternately, a 4 -All scupper box may be field HaM using n d to :. to the scupper box and terminate on the outside wall face m llilf 111IMMMIRI MITURITTAI �Wftm 1. Field -fabricated two-piew inerribrane flzhings of rCru t flashing ly installed at heap stacks. "uard have cone- qrpeprefabricated pipe flashingthat may in these applications, If not., then field -fabricated membrane 'a" as uardd�' 'ling Membrane may be Q Y tli i ail l�iatt'C It that comes into pith the r4;naed or flashing should riot exceed I F € f OC or 1900F HIM for Everguard ftueme mofings. . Heat stacks must be equipped with either cone-sliaped or vertical type flashing sleeves so that the inembrane flashing is not directly in contact with the heater stack- 3. Mechanically aftitch the red tnembraneto the gructural, deck with Dill TW' sam and plates around the penewhin base prior to flashing installabom . All stack flashings must be secured at their edge by a til damn bard r"i`t KOA FlexSeal Caulk Cirade caulking. , the detail with 'iOKOA FlexSeal Caulk Giade caulking, . Field-fabricatedr e Udungs inzy be adhered to die flashing sleevewith RvrGuardO 7PO or FverGuardO MA BoadingAdliesive, 1" p G asard* PVC roofeng membratte is typically terminated at PVC dmin insens by tding the Ween to the in flange (if available), or by securing flee mernbrane bebeen the drain flange and the damping rings. 2. h ITO drain inserts have an int nmitbrarie for welding to the frld membranc, I Drain inwAs ani only be used in the, event the original drain is daumo and caunut be repted vAthout connilete replacement of the draim . All drains must be provided, wfih a drain sump of a(;' (9,14 ) a W (914 )" di , if a p'ble..Fas m be ' 12"° (305 ) ox. or a minimum e (fraaar)per penetration, 5. 'ga insert is insirdled on top of die roofing mendinme and is secured to die mof dock 6" (152 nun) o.c. with Drill- Tcc�, screw . A selyarde reinforced b "n flashing shed is heat welded to the mofing shed is beg welded to a compatible drain flangt T Install tine dron damping rind if 2Wicable, . All drams must be provi"with a strainer basket " hoof" drams must be open and functionitig," 10. Cd sing dee length of the drain line is required so that the t drain will seal to the pipe, failure to dear this section of drain line can prwmt the sealing of are drain and degrade the t of the 'n seal. Q, Wood Support Blocking 1. Wood support blockffi& typically " (101 mm) x 4" (102 mut), is usually installed under tight-dcaty, or temporary roof-ruounled equilauent such, as el cal conduit, gas lines, and condmudon xW draan lines. 2. install wood support is "ng over a protective layer of FwTGuare TPO Wkway rolls or MIC walkway pads, Place wood Woddng on oversizedslip shert, fold two sides veru y, and faster, with roofingnads into the him Wig, I If using pre-fiditicated pipe stantis with rubber -like no slip sheet is resew,. R. Satellite Dish SUPPDtt 1. Irr all sa n to at a support bay over aprotective layer of MeMbrAne. S, lightning; Suppression CI 1. Secure lightning suflnesdon dips to the rod surface by means of " (51 i) w" PVC or r TPO flashing membrane st " beatuvided to the mof M 3.12 T" A" y calls or lard at. all tl ncfoil I , stairs, . 11 ally y € r at ignated locations, lncd egret t locations s cd ate ti. Walkway rolls or pads most be spaced 6" (152 ) to allow for C Heat weld walkway stalls or pats to the toof membrane surface continuously around the walkway penmeter. D. TPP walkway tells nuy also be msWkd with TPO prow " n , Firsk nail orb die 1TO primer" an the back of the TPO stall along the edges and down the n*kDe of the length of the mall, Clem and prime the roof membrane where the roll will be installed.1 all tape to the back of the mall where ed (edges and middle) and mill in with a sificone hand roller. Rerruwe the release paper and iarstall the rolls ifireedy onto the mof niernbrane, Secure the nails by rolling into Plact 3.13 Temporary Closures A. The molorg instaffation amst be arcade watertight at the, end of each day's activity to prevent water infiltration into the corojileted mofing systan instillation. It Complete ad flashings antl lerminationsas the roofing insullation program. C. At the of the completedsag T. tern instaflabon, exterid die mofing mernfirane anuniaaaa `° nan), beyond the edge. Seal the roofing mernline to the surrounding ded- or substrate surface vAth bot asphalt or foam sealant D.'Remove all tempotary`night-seal materials parker to continuing with the roof installation and dspose of 3.14 Fidd QuAty Cattrol contradWs nalionsibility to probe all heat -welded scum and perform an attequate uutrberof searn cuts to ascertam =n f e 3.15 Ciming ,t Rmw, brWing adhesive, biturninous markings, aW Odws Cotuandnants front Cir " surfaces, in am where firuslied surf scot by alt or any r source ° of u by work of titts or raiser sections,t manufacturer of sinfaces for dearong, advice and confrim to hISMICOMI& A. Upon completion of die sag„ s . , the owner shoWd establish a senti-yearlyt" maintenance program In wvdance with st"�d good mofing P-ACUCC and guarantee rtti .sats. B.. Repair cuts, punctures, and cuter its carte damage by cleaning (scesection 3,11 D), fail by heat welifing a membratte rqw palch of sufficient size to extend a minimum of " 3 ) beyond the dantao arm if heA- welifing to the top sufface of the, exisung juern, Irrmle is indective, the patch inust, he heat wekW to the underside of the existing sheet after prWff timparation, C Arw damage to adherede areas or at locations 4 utechzcal a t including Insulation, m be reltured so that the reltafted area remains full} Aered or niechanically IM DETAIL NAME DETAIL NUMBER PAGE ROOF MEMBRANE LAYOUT IOTA 47 SIDE LAP 102A 47 COVER STRIP END LAP 103 48 END LAP 104A 48 T t 11T CCIYER PATCH 105A 49 ROOF AREA ZONE LAYOUT io6 49 R ID GE I WA 50 CHANGE Of PIANE 112 50 Y 13A 51 CUT EDGE SEALW 115 51 MEMBRANE EDGE n6 52 COATED ETAL ROOF E1 E 202 52 COATEDMETALJOINT 204 53 SNAP-ON FASCIA ROOF EDGE 206 53 ROOF EDGE WITH TPO COVER ER TAPE 213 5 TPO COVER TAPE OVERLAP AT ROOF EDGE 215 5 METAL DRIP EDGE CORNER 216 55 WW,IJRB FLASHING WITH TERMINATIONBAR 302 55 NEW CONSTRUCTION N TH WALL CAP 303 56 ALL FLASHING WITH COATED METAL EDGE 304 56 ALTERNATE WALL BASE TERMINATION ATION 07 57 COATED AL WAU, FLASHING 308 57 COATED METAL WALLUIPPER 311 58 VERTICAL WALL EDGE TERMINATION WITH COATEDMETAL 314 58 R.T,A. STRIP m INSIDE CORNER REINFORCEMENT 326A 59 INSIDE CORNER REI RCEii F -PREF R IEII CORNER 327A 5 tit IDE CORNER REINFORCEMENT -PREFORMED CORNER 329A 60 FAC RY FABRICATED EXPANSIONJOINT-FIAT TYPE 401A 60 FACTORY FABRICATED EXPANSION JOINT -CURB, TYPE 402A 6t FACTORY FABRICATED WALL EXPANSION JOINT -FIAT TYPE 403A 61 TERMINATION AT RTU. WITH WELDED LAP 503A 62 TERMINATION AT RTU. WITH COUNTER FLASHING 5038 62 PREMOLDED VENT BOOT FLASHING 506A 63 DRAIN STANDARD ROOF DRAIN FLASHING 513 63 POURABLE, SEALER POCKET 525 64 HEAT-WEIDED WALKWAY INSTALLATION 604 64 . Refer to www.gaf corn for a cmo& fig of ° Ie (SAF Roofing ° '1s. 12 El I/ I Im Lul I I I F.R RE RE rm Im �k 6k9 W gy Y 5T77 ......... . ... A l Ski a. � a Im IE 9 a] 0 I I I I M im I 2 m I m a I m m I I ul N I M I R M. Im 11 - UB I a] J._ .49 oit I FOR OFFICE USE ONLY City of Daft N� Wh6atf 4'dge t tiwfiJi tDEVELOPMENTPie it Building & Inspection Services division 7500 W.29th +e., Wheat Ridge CO 80033 Pian Review Office: 303-235-2355 * Fax: 303-237-8929 Inspection Line: 303-234-5933 +" ` d"r (pease iarrh: (if different than property address) Address. f$ City, State, Zip: AV tr�ci: Electrical: Plumbing: Mechanical, W.R. City License # WA. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Stab: City License # City License Complete all information on BOTH sides of this form TIMM" RM .+►# R # 777 (Contract value or the cost &4&jjj� labborir�Q60i6thetdkjOOOJW' *e SK41- 1 #Division NM Ex• City of Wheat Ridge, Municipal Building 7500 W. 29h Ave, Wheat Ridge, CO 80033-8001 P: 301235.2855 F: 301237.8929 --------- .... 9240 & 9340 W. 49th Ave Wheat Ridge, CO 80033 1224 Wadsworth Blvd. Lakewood, CO 80214 Notice is hereby served that the City of Wheat Ridge Bung and Inspection Services Division has determined that the property commonly known as 9240 W. 49' AVENUE Wheat Ridge, CO 80033 and 9340 W. 49" AVENUE Wheat Ridge, CO 80033 is in violation of the 2012 International Building Code and the 2012 International Property Maintenance Code as adopted by the City of Wheat Ridge. Stairways have been rebuilt on the property without the required building permit, specifically the Northwest and Southeast stairways of the building located at 9240 W. 49th Avenue, and the Southwest stairway of the building located at 9340 W. 49tb Avenue. The construction of these stairways has commenced without the required building permit, is substandard, and is creating an unsafe condition. SECTION 105 PERMITS [A] 105.1 Required. Any owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or plumbin Lt the required permit. uppiTuation to me oulloing oincial and o6tain SECTION 1009 (IBC) STAIRWAYS 1009.7 Stair treads and riserl vv,wwA.whPs#tridfrP,rn.ttv :I «« 1<«;},: *z) N 3 «z° *f Th-Ifitt SECTIO04 EXTERIOR STRUCTURE Kill's 111 »;r: c:» ft�= 1 111 1 Mirwil i I I VXI md capable of supporting the loads. 2TTET-1 orders tnat ,«<: Ing permit be obtained tor the construction and alterations of the above mentioned stairways and shall be brought into compliance with the current adopted codes of the City of Wheat Ridge. Repairs shall commence within 30 days. ?e`' R. Bradley Umbarger Combination Inspector 7500 W. 29th Avenue Fax: 303-237-8929 mxK.ci.wheatridge-qo-u,-; I I of at ic W, 7 Building & Inspection Services Division 7500 W, 29' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax 303-237-8929 Inspection Request Line 303-234-5933 (please print): Elo c� koe (t' (if different than property address) Phone: Address: City, State, Zip: 0 o- is K—De!s(4&If fII5---- --- -- � 1---- Contractors City Licenso #: Electrical: Plumbing: Mechanical" City License If City License City License # USUC WORkS C , OMMENTS: evict t". IRE DEPARTMENT:. 0 app6ved w/ COME plait Permit Phone: Address: City, State, Zip: 0 o- is K—De!s(4&If fII5---- --- -- � 1---- Contractors City Licenso #: Electrical: Plumbing: Mechanical" City License If City License City License # USUC WORkS C , OMMENTS: evict t". IRE DEPARTMENT:. 0 app6ved w/ COME Maid To; K-Des gners /LakewoodM Ship to K- Designers /LakewoodAA! District Sales Manger: 2440 Gold River Road 5825 IN 6th Avenue SMITH, G Suite 960 Unit 3C Super Service Team: Gold River, CA 95670 -6360 Lakewood, CO 80294 -2460 Lisa,Crystal, Ruth Order Rate. 9/03113 Ordered By: � Ship Date: 9/16113-9/18113 Order No: 01628547 Pt7 #: 302318 volume Disc ID: Terms: 1.5%30,1%60, Net 61 Contractor; Rodriguez U fact S HGC DP List Price Discount Discount Price Exte nded Price R .30 R -29 DP -25 Window Drawings are representations Only. Sight lines and ry grid alignment may differ from the actual product. 0 $0M Line #01 DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number Date 14023 6/13/02 Property Owner: GARY GALGER Property Address: 9240 W 49TH AVE #307 Contractor License No. : Company : Phone: 332-8104 Phone : OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certiTy that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code ~(U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. Construction Value : $400.00 Permit Fee : $23.50 Plan Review Fee : $0.00 Use Tax : $8.00 Total: $31.50 (OWNER)(CONTRACTOR) SIGNED ATE ~ Use: Description : 27X33 AIR CONDITIONER PLACED IN 2X6 EXTERIOR WALL, 110 OUTLETM, 12K BTU UNIT BUILDING DEPARTMENT USE ONLY ~ SIC : Sq. Ft. : ~ =-~-,ti~_m9Td,~ Approval : Zoning : . ,00WOKAY Approval: DM P 011.0! ~ ~ MM"'k- . Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval: Plumbing License No : Company: Expiration Date : Approval : Mechanical License No : Company : Expiration Date : Approval : (1) This permit was issued in aaordance with the provisions sel forth in yopur application and is subject to the laws oFihe State of Colorado antl to the Zoning Regulations and Builtling Code of Wheat Ridge, Coloratlo or any other applica0le ordinances of the Ciry. (2) This permit shall expire if (A) the work authorized is not wmmenced within siuty (60) days trom issue date or (B) the buiiding authorized is suspended or abandonetl For a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, providetl no changes have been or will be made in the original plans and specifcations and any suspension or abantlonment has not exceetletl one (1) year. If changes are matle or if suspension or abantlonment exceeds one (1) year, full fees shall be paid tor a new permit. (4) No work of any manner shall be done that will change lhe natural Flow oFwater causing a tlrainage problem. (5) Contraclor shall nolify the Building Inspeclor hventy-four (24) hours in advance for all inspeclions and shall receive wntten approval on inspeclion card before proceetliing wit ccessive phases of the job. (6) The issu a ermi or t epproval of drawings and specifwtions shall not be wnstrued to be a permit for, nor an approval of, any violation of ihe provisions he uil i or any other ortlinance, law, rule or regulation. ~ . .~~'iY)••e.- . ~r~~~ Chief Building InspeCtor DEPARTMENT OF PLANNING AND DEVELOPMENT Building Penrit Nuinber: oF W"E °j BUILDING INSPECTION LINE - 303-234-5933 Date: _ g CITY OF WHEAT RIDGE 7500 R'EST 29TH AVEN[JE WHEAT RIDGE, CO 80215 - (303-235-28p5Y5,~) j COC OR P0~ PPU~t.P~ ~.l O7~~- ~l r Property Owner: GAn-Y p AvE ~~0~ Phone : C3~3~ 3~ a~ g~~y Properry Address: 't'1 ? N ~ ' ~ q ~ ~ Contractor License No.: Company: Phone: OWNER/CONTRACTOR SIGNAT[1RE OF I7NDERSTANDING AND AGREEMEIVT I hereby cerUfy thatffie setback distances proposed by this perrttit applicazion aze accurate, and do notviolate applicable ordinances, mles or regulations of thc Ciry of Wheat Ridge or covenanu, euemenfs or restrictions of record; that all meuurements shown, and a(lega[ions made aze accurate; that I have read and agree ro abide by ail condi[ions printed on [his application and that I assume full responsibility for compliance with [he Wheat Ridee Building Code (U.B.C) and all other applicable Wheat Ridge Ocdinances, for work under this permit. COMVER)(CONIRACTOR):SIGNED 1~~..-.' ~ATE 0' - ~ Value:$ ilOU, UD Permit Fee:$ 23 16 Plan Review Fee:$ Use lax:$ I TOt&1'$ 7~SQ ~Qescription: /NSTqZ~ tiEw f11iz GoNDIT/ONC?L BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: pUBLiG WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Plwnbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expirarion Date: Expiration Date: APProval: Approval: Approval: (I) I7us pennit was issued iu accordauce with fhe pmvuions set forth in your application and is subject ro Um laws of the Statt of Colorado and ro the Zoning Regulafions and Httildiug Codes of ~F^neat Ridge, Colorado or e¢y oNer applicable ordinances of Ne CiTy. (2) This pecmit shall expire if (A) the work authorized is not commenced wiehin siuty (60) days from issue date or (B) tlie bnilding zutlionzed is suspended or abandoned for a period of 120 days. (3) ff this permit exp'ves, a vew persait may be acqvired for a fee of one-half the amount no{malty required, proviAed no changes have 6een or will be moAe in Uie original plans andspecifi<atlons and any susp<nsmn or abandomnent 6as not exceeded one (1) yezr. lfchanees have 6een or if s,,s➢ensmn or abanAonmenr exceeds one (1) yeaz, full fees shall be paid for a new pmnit. (4) No work of any manuer sha116e done that will change tlie natural flow of wamr causing a drainzge problem. (5) Contractorshall notifytlteHuild'wglnspectorhventy-four (24)honrsinadvanceforallinspechonsandshallreceivewnttenapprovalanmspecbancarAbefore proceeding wiUi sncttssive phases oFdiejob. (6) The issuance of a permit or the approval of drawings and specifica¢ons sliall wt 6e consWed ro 6e a pmmit for, nor an approval of, any vialetion of the provisiovs of Nm biilding codes or avy other ord'wance, law, rule or rogdatioo. Chief BuIlding Inspector qo G'~-r-~-- ~ ~ INSPECTION TICKET Joa l'~?~J ADDRESS . ~ DATE: F ' "-BLDG. PERMITM PERMITB BLDG.CONTR SUBCONTRACTOR DATE INSP. REQ. TYPE OF INSP. INSPECTION MADE REMARKS W.R. FORM 5-19 / DEPARTMENT OF GOMMUNITY DEVELOPMENT 7500WEST29thAVENUE BUILDING INSPECTION DIVISION PERMIT N0. M94#19171 234-5933 P.O. BOX638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SiGNED BY THE CHiEF BUILDING MSPECTOR AND RECEIPTEDBELOW. 0 (J Z/ 7( 7 OWNER .)eS.tF/i JOB ADDRESS - 1 ADDRESS dJ (O I _ CONTRACTOR ZIP CODE CZ ADDRESS ~ ;n~• ~ ~v % ~y PHONE • ~ nCI+ ZIP CODE CONTRACT P RICE $ CITY _41 PHONE ` 4 6 V LICENSE NO. DATE ❑ wall❑ ProleWinp❑ OtMr SaDFeee . TYPE Ground 1. MATERIAL To1ol Squore FeN T I ❑ ❑ Permil No El~et SIGN I No TYDe LIUMINAT10N Yq I . . l l SET BACK FROM PROPERTY LWE N_ 5_ E - W Zone _ ApprwM.ZOne In"da (soscifvwhicniafront) ❑ ❑ ❑ Diwpproved 1. TYPE SolidU Mon Thon BO% OpenU Len Thon BO% Open FENCES MATERIAL HeipM '.S. SET BACK FROM PROPERTY LINE N_ S_ E_ W Zano_ Apprwaid,Zorn Inspeetw (Spscity wnien is front) ❑ ❑ ❑ ❑ DisapDrowd / OTHER -4-vt°-~ s. APP DRAW SKETCH OR SHOW BELOW,THE FENCE,SIGN,OR OTHER STRUCTURE,GNIRv" DIS' (SETBACKS OR PROJECTIONS MCLUDED) INSPECTION TICKET STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TPADJOINING HOUSES, STREETS, AND PRd DISTANCE TO PROPERTY LINES,NOT MAXIMUM OR AVERAGE OlSTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; Mi THIS A.PPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY 0 PERMIT WILL EXPBE 180 DAYS FROM THE DATE OF ISSUANCE IF WORf ELECTRICAL PERMIT STATE LICENSE N0. PLUMBING PERMIT WSPECTION MADE S7ATE LICENSE N0. REMARKS O'C WAtt) ALUMINUM VNRE UNDER SIZE 8 ILIEGAL fL00R BSM IST 2ND 3R NO - WATER CLASET TEMPORARY METER WASH BOWL NEW SERVICE - AMPS BA7H TU8 CHANGE SERVICE-AMPS SHOWER M b19 LIGH'fING SINN W.R. FOR HEATIN6 GARBAGE DISP POWE:R SUB-LIFCUITS WQTEF HEATER UTIUTY(RANGE,DISPO5ER,ETC.) AUTO.WASMER FIXTURES ~ DISH WASHER mi~vmuin. armnnLertaraiem WIRIMG MOTORS 9 CON7ROLS FI.DbR DRAIN ELEVAtOR SIGN!i URINGI TRAMSFORMERS 9 RELTFIERS SEWERS ADDI'fION TO OLD WORK OTHER MOTORS OVER I NP TOTAL FI7(TURES lica- t tni PERMIT FEE s aDV I hsreCy ocM.nowledpe tha tion is torrect and understand thot I USE TAX eannot start this Drojett unfil this oppli- cation ie op0raved. I sholl comvlY with TOTAL FEE fha lows oi Ihe Stote of Colorodo ond to ihe Zoninp Repulations and Buildinq PPROVE Code oftne City ol Wt+eat RidQe. Any DIS violation of tne above terme will cause CHIEF BUILDI immediale revocation ot tnis permit Joa cl ~q U C~ q ~L-k ADDRESS ` j1m DATE: q`~-~ y BLDG. PERMITM CIl l'I I SUBCONTRACTOR PERMITB BLDG. CONTR.~ DATE INSP. REQ. TYPE OF INSP. J In I $ 3 af V- _ ~ INSPECTOR,City of kleat Ridqe Date Issued slaeewr~- NOT VALID UNLE55 RECEIP ti C", b➢ tA !S Ci UG CALL 234-5933 24 HOURS IN ADVANCE FOR INSPECTIONS 7500 WEST 29TH AVENUE P.O. eox ssa The City of WHEAT RIDGE C080034-0638 (303) 234-5900 cWheat City Admin. Fax # 234-5924 Police Dept. Fax # 235-2949 GRidge December 21, 1993 Great West Management Co. c/o Charlie P.O. Sox 848 Westminster, CO 80030-0848 Dear Charlie: It has come to my attention that the roof o£ the building located investigation of this complaint, light: there is an ongoing problem with at 9240 W. 49th Avenue. Upon the following concerns came to 1. Water damage to the drywall 2. Water damage to the electrical 3. Dry rot of structural elements 4. Mold and mildew Considering these items, i must inform you that this building may be considered a dangerous building under the Uniform Code for the Abatement of Dangerous Buildings, Articles 302-5, 302-9, 302-15 and 302-16. If the damage is not corrected, the City of Wheat Ridge Building Department may condemn this structure and order it razed as authorized by the Uniform Code for the Abatement of Dangerous Buildings. if you have any questions, please feel free to call me at 235-2853. Sincerely, ~ ~ ~ John W. Eckert Building Inspector JWE/at 1tr9240W49thAv c, ,t