HomeMy WebLinkAbout6840 W 48th AvenueCity of Wheat Ridge
Residential Roofing PERMIT - 201707566
PERMIT NO: 201707566 ISSUED: 09/22/2017
JOB ADDRESS: 6840 W 48th AVE EXPIRES: 09/22/2018
JOB DESCRIPTION: Residential Re -roof to install Atlas asphalt shingles with ROOF DECKING -
23 sq (20 sq pitched / 3 sq flat) Pitch = 6/12
*** CONTACTS ***
OWNER (303)274-5474 JOHNSON WARREN G
SUB (303)757-5555 Brian Cung 100121 Rocky Mountain Roofing & Rest.
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,707.88
FEES
Total Valuation 0.00
Use Tax 161.87
Permit Fee 172.60
** TOTAL ** 334.47
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name)
roof covering" is required to be on site at the time of final inspection.
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped
off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the
Homeowner.
City of Wheat Ridge
Residential Roofing PERMIT - 201707566
PERMIT NO: 201707566 ISSUED: 09/22/2017
JOB ADDRESS: 6840 W 48th AVE EXPIRES: 09/22/2018
JOB DESCRIPTION: Residential Re -roof to install Atlas asphalt shingles with ROOF DECKING -
23 sq (20 sq pitched / 3 sq flat) Pitch = 6/12
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications
applhcabble building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
thispermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and Aat all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
1-z 5- C
Signature of OWNER or CONTRACTOR (Circle one) Date
I. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Dat `rte,
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dane Lovett
7
From:
no-reply@ci.wheatridge.co.usa
This is exclusively for new for residential roofs and for licensed`
Sent:
Thursday, September 14, 2017 3:02 PM
contractors only. This type of permit is ONLY being processed online --do not come
To:
CommDev Permits
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
Subject:
Online Form Submittal: Residential Roofing Permit Application
V
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
1
�\—
your contractor's license or insurance has expired, and you may update those
i
documents at the time you are issued your permit.
Follow Up Flag:
Follow up
Flag Status:
Completed
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address 6840 W 48th Ave.
Property Owner Name Warren Johnson
Property Owner Phone 303-274-5474
Number (enter WITH
dashes, eg 303-123-4567)
97
Residential Roofing Permit Application-
This is exclusively for new for residential roofs and for licensed`
application permits
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in_z,_
N
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
c
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
1
�\—
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address 6840 W 48th Ave.
Property Owner Name Warren Johnson
Property Owner Phone 303-274-5474
Number (enter WITH
dashes, eg 303-123-4567)
97
Property Owner Email
Address
Do you have a signed
contract to reroof this
property?
Applications cannot be
submitted without an
executed contract
attached below.
Attach Copy of Executed
Contract
Field not completed.
Yes
6840 W 48TH AVE CUSTOMER AGREEMENT.pdf
CONTRACTOR INFORMATION
Contractor Business
Name
Contractor's License
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Rocky Mountain Roofing & Restoration
100121
Contractor Phone 720-490-5747
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Address 1685 S Colorado Blvd. S176 Denver CO 80222
(Primary address of your
business)
Contractor Email Address edith@rkymtnroofing.com
Retype Contractor Email
Address
DESCRIPTION OF WORK
TOTAL SQUARES of
the entire scope of work:
Project Value (contract
value or cost of ALL
materials and labor)
edith@rkymtnroofing.com
23
r
575O. -OG --
Z1701,
750. -00_,.Z1701,
Are you re -decking the Yes
roof?
Is the permit for a flat Flat roof (less than 2:12 pitch), Pitched roof (2:12 pitch or
roof, pitched roof, or greater)
98
both? (check all that
apply)
What is the pitch of the 1:12
FLAT roof?
How many squares are 3
part of the FLAT roof?
Describe the roofing Modified Bitumen
material for the FLAT
roof:
Type of material for the Other (specify below)
FLAT roof:
If "Other" is selected Modified Bitumen
above, describe here:
What is the specific pitch 1:12
of the PITCHED roof?
How many squares are 20SQ J l
part of the PITCHED
/ !
roof?
Describe the roofing
materials for the
PITCHED roof:
Type of material for the
PITCHED roof:
Atlas Storm in Weathered
Asphalt
Provide any additional remove & replace comp. shingle with Atlas Storm in Weathered
detail here on the
description of work. (Is
this for a house or
garage? Etc)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
99
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Name of Applicant Brian Cung
Email not displaying correctly? View it in your browser.
100
ROCKY MOUNTAIN
1685 S. Colorado Blvd. Unit 5-176 Denver, CO 80222
Office 303-757-5555 Fax 303-757-0027
CUSTOMER AGREEMENT
3578 Hartsel Dr, Unit E-122 Colorado 5prings, CO 80920
Office 719-792-4245
Property Owner RkyMtnRoofiing.corn - Licensed & Insured
Al Email
r
S reel Address
�i ��� RMRR Est#imator
City, State Zip ,f # t (e
Insurance Company
Ia
Home Phone Work Phone Claim #
91�No Deposit Required
Damage- yesno
HOUSE GARAGE
Roof Type:
Drip Edge Color:
T
Date
Ejr3 year Roof Labor Warranty WIVGen. Liability/ Workers' Com
P• BSB Accredited
Full Partial Repair Full Partial r
— Damage: yes Type:
PATIO SHED SHE T VINYL WOOD OTHER:
Inspect Flashings
e p & Remove Trash
OTHER:
Style: _ Color:
" Full Part-al�"'R�7
5"- Res. 6'- Comm. Alum. Steel
Lf.— Color:
Work to be completed according to the above specifications in the amount of:
(not to include insurance su Ier)—pts,pparut costs or any unforeseen constructm costs) r
C
❑ Balance due upon completion ❑ CASH SALE Ct yfi
("INSURANCE AGREEMENT. The homeowner authorizes Rocky Mountain Roofing & Restoration to represent their
hes interest in pursuit of full replacement costs for damages believed to be covered under homeowner's insurance and
allows Rocky Mountain Roofing & Restoration to deal directly with the insurance company regarding this claim. This
contract does not obligate the homeowner or Rocky Mountain Roofing & Restoration until the claim is approved by the
insurance company, and accepted by Rocky Mountain Roofing & Restoration. Upon approval of claim, Rocky Mountain
Roofing & Restoration will complete all specified worm at a price agreeable to the insurance company (RCV only) and
Rocky Mountain Roofing & Restoration, with no additional cost to the homeowner except for the deductible. Final agreed
upon price will become the final contract price, regardleass of estimated contract price above, and we request that all
payments also be made payable to Rocky Mountain Roofing & Restoration.
I (We) agree, by signing below, to all the contract conditions on both front and back, of this agreement.
Homeowner's Signature: Date of Acceptance:
Horruowrier's
> City of Wheat Ridge
Residential Roofing PERMIT - 201707566
PERMIT NO: 201707566 ISSUED: 09/22/2017
JOB ADDRESS: 6840 W 48th AVE EXPIRES: 09/22/2018,
JOB DESCRIPTION: Residential Re -roof to install Atlas asphalt shingles with ROOF DECKING -
23 sq (20 sq pitched / 3 sq flat) Pitch = 6/12
*** CONTACTS ***
OWNER (303)274-5474 JOHNSON WARREN G
SUB (303)757-5555 Brian Cung 100121 Rocky Mountain Roofing & Rest.
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,707.88
FEES
Total Valuation 0.00 PAID
Use Tax 161.87
Permit Fee 172.60
** TOTAL ** 334.47
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name)
roof covering" is required to be on site at the time of final inspection.
Midroof '& Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped
off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the
Homeowner.
► , City of Wheat Ridge
'(9Residential Roofing PERMIT - 201707566
PERMIT NO: 201707566 ISSUED: 09/22/2017
JOB ADDRESS: 6840 W 48th AVE EXPIRES: 09/22/2018
JOB DESCRIPTION: Residential Re -roof to install Atlas asphalt shingles with ROOF DECKING -
23 sq (20 sq pitched / 3 sq flat) Pitch = 6/12
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performedar�d hat all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing, and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and maybe subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance, or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicab or any oordin or re ala Jon of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
MIT: ADDRESS:
JOB CODE
(ZIZ
INSPECTION RECORD
Inspection online form: http://www.ci.wheatridge.co.us/inspection
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site
Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business
Foundation Inspections
Date
Inspector
Initials
Comments
102 Caissons / Piers
103 Footing / P.E. Letter
104 Foundation Setback Cert.
105 Stem Walls
106 Foundation wall Insulation
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground / Slab Inspections
Date
Inspector
Initials
Comments
201 Electrical / Cable/ Conduit
202 Sewer Underground Int.
203 Sewer Underground Ext.
204 Plumbing Underground Int.
205 Plumbing Underground Ext.
"ter Underground
row-
Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections
Rough Inspection
Date
Inspector
Initials
Comments
301 Rough Framing
302 Wall Sheathing
303 Roof Sheathing
304 Sheer Inspection
305 Insulation
306 Mid -Roof
row-
307 Metal / Lath / Stucco
308 Rough Electrical Residential
309 Rough Electrical Commercial
310 Electrical Meter Residential
311 Electrical Meter Commercial
312 Temp. Const. Meter
313 Rough Plumbing Residential
314 Rough Plumbing Commercial
315 Shower Pan
SEE OVER FOR ADDITIONAL INSPECTIONS
Rough Inspection (continued)
Date
Inspector
Initials
Comments
316 Rough Mechanical Residential
317 Rough Mechanical Commercial
318 Boiler / Furnace
319 Hot water tank
320 Drywall screw and Nail
321 Moisture board / shower walls
322 Rough Grading
323 Miscellaneous
(0 1( %
l
3W C&I X02`
Final Inspections
Date
Inspector
Initials
Comments
402 Gas Meter Release
403 Final Electrical Residential
404 Final Electrical Commercial
405 Final Mechanical Residential
406 Final Mechanical Commercial
407 Final Plumbing Residential
408 Final Plumbing Commercial
409 Final Roof
(0 1( %
l
3W C&I X02`
410 Final Window/Door
411 Landscape/Park/Planning
Inspections from these entities shall be requested
one week in advance.
For landscaping and parking inspections please
call 303-235-2846
For ROW and drainage inspections please call
303-235-2861
For fire inspections please contact the Fire
Protection District for your project.
412 Row/Drainage/Public Works
413 Flood plain Inspection
414 Fire Insp. / Fire Protection
415 Public Works Final
416 Storm Water Mgmt.
417 Zoning Final Inspection
418 Building Final Inspection
Note: All items must be completed and approved by Planning, Public Works, Fire and Building
before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not
constitute authorization of occupancy.
For Low Voltage permits please be sure that rough inspections are completed by the Fire District and
Electrical low voltage by the Building Division.
The City of Wheat Ridge
-a� Third Party Form Ch ck ist
Property Address `l 0 ) t�t,
Permit Number _
Permit Issued Date
Owner Information
Property Owner Information
Property Owner Address
Inspection Company
Inspector Name
Inspector Contact info.
114 rid ToWoa
(o Lyre 4) �ZAJIA-Aye
Inspector Statement and Acknowledgement
* I hearby acknowledge the roof I am inspecting is 6/12 or over all roofs
that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept.
* I hearby acknowledge the roofing system for the referenced building has been inspected
and found to be in compliance with the minimum requirements of the 2012 IRC and 2012
IBC as well as all City of Wheat Ridge Policies and Procedure and Manufactuferls
recommendation n ti�� C 2
Inspector: ,-�� - Date:
11/
Pro rtv Owner Statement of Acknowledaement
*1 hearby acknowledge that I am the owner of the building referenced above
my consent for the listed third -party inspection company to perform my roof it
in lieu of the City of Wheat Ridge Building Digi i ins ection. /}
Propery Owner/ Agent: Date:
This original document as well as the roofing check list, must be submitted to
Building Offical within seven days of the final inspection.
Drop off in person Submit via Email
Permit counter 2nd floor Kcook%ci.wheatridge.co.us
7500 W. 29th Ave
Wheat Ridge CO 80033
�OG
Drafted Date: 7/26/17
Please add note to reverse side
M
n
2�_
Chief
The City of Wheat Ridge
inspection Check List notes
Mid -Roof
ction
Roof inspe.
• N/A 0 Pass 0 Fail
Pass 12 Fail
Structural roof components
• N/A
0
Verify that no more than 2 layers of shingles exist
• N/A Pass Fail
[1 N/A )1(Pass E3 Fail
Flashing for roof and walls
If new sheathing is installed verify that it is listed in the
�r Pass c Fail
permit description (Valuation must be adjusted)
X Pass 0 Fail
Verify sheathing nail pattern ( See policy & Proceedures)
/A
`"/nzr
Crickets and saddles where needed
r3 Pass 13 Fail
Pass Fail
Verify B vent must have boot same gauge as pipe
�,/q
Pass 0 Fail
Verify vent caps
Q N/A
13 Fail
Verify no flashings are damaged or rusted
0 N/A Pass
"%ass c Fail
Step flashing shall be min. of 4x4 piece per shingle
a N/A
0 Fail
Verify scuppers allow for proper drainage
0 N/A ass
Past 0 Fail
Ice and water shield 2' in heated wall spaces
0 N/A
0
Underlayments must follow 2012 IRC / 2012 IBC
0 N/A t�Pass Fail
Pass 0 Fail
Verify roof slope for proper drainage
0 N/A
o Fail
Dripedge shall have min of 2" overlap
0 N/A pass
o Fail
Dripedge should extend down min 2" past roof deck
0 N/A ass
0 Fail
Dripedge shall be mechanicaly fastened 12" OC
n �/A ass
90 LB roll roofing shall not be applied to roof slopes
/A ct Pass 0 Fail
less than 2:12 slope: Exception, detached garages,
patios, carports, open on three sides with min, slope of
1:12
Modified Bitumen, EPDM, TPO min slope 1/4:12 slope
N/A i3 Pass 0 Fail
Above roof insulation R-25
N/A 13 Pass 13 Fail
13 Fall
Below roof residential R-38
N/A 0 Pass
Below roof commercial R-32
N/A 0 Pass 0 Fail
Modified Bitumen, EPDM, TPO min slope 1/4:12 slope
N/A a Pass 0 Fail
be installed in accordance with the manufacturers
must
specifications- Must have manufactures letter of
warranty with the address on the letter for final inspection
(fetal Roof Shingles
Requirements
1N/A E3 Pass la Fall
Metal roof shingles shall not be installed on slope less
3:12
Metal valley flashing shall be the same material as roof
" U pass 0 Fail
O/A
Metal valley flashing shall extend a min of 8" from the
/A Pam 0 Fair
centerline with a min. of 314 " high splash diverter
rib built-in at the flow line with sections overlapping a
a min. of 4"
The Roofs Requirements
Q Fail
Clay and concrete the shall have a min. 2-112:12 slope
/,41 N/A p Pass
Slopes 4:12 and under require double underlayment
The City of Wheat Ridge
Inspection Check List notes
Mid -Roof
Notes
Company Name:
Inspector signature: '
Date of Inspection:
The City of Wheat Ridge
Inspection Check List notes
Final Roof
Rauf 1113222
VA 13 PW
VA paw
ton
0 Fail
0 Fail structural roof components
Pass
13 Fail Verily that no more than 2 layers of shingles exist
a/A
Pass
o Fail Flashing for roof and wall
VA
PUS
D Fait 1f new sheathing Is installed Verify that $ listed in the
permit description (Valuation must be adjusted)
� Pass
to fail Verify sheahing nail pattern (See policy $ Proceedures)
VA
o Past
a Fait Crickets and saddles where needed
VA
VA Pea
€3 Fail Verify B vent must have boot saute gauge as pipe
M/A Pau
a Fail Vaulty Vent capes
1:/A . PM
a Fail Verify no flashings are damaged or rusted
14/A X Pass
a fall .Step flashing shall be min. of 4A piece per shingle
WA � Pass
o Fall Verify scuppers allow for proper drainage
Pass
o fall ice and water shield 2' In heated wall spares
hd/A
Psi
Fall must follow 2012 IRC / 2412 IBC
MIA
Paas
Sa Fail Verify roof slope, for proper drainage
N/A
WA %` Pass
a Fail Dripedge shall have min of 2" overlap
'troan
to Fail Dripedge should extend down min 2" past roof deck
/`pass
13 Fail Dripedge shell be mechanicaly fastened 12" aC
0 Fall 90 LB roll roofing shall not be applied to roof slopes
N/A El Pass
less then 2.12 slope: Exception, detached garages,
patios, carports,, open on three Sides vVl€1"l min. slope of
a Pass
0 Fail Modified Bitumen, EPDM, TPO min slope 1/4:92 slope
Modified
N/A
N/A o Pass
0 Fail Above roof insulation R-25
NIA 0 Peas
Q Fall Below roof residential R-38
N/A a Pass
0 Fail Below roof commercial R-32
a Pass
a Fail Modred Bitumen, EPDM, TPO Chin slope 114:12 slope
N/A
must be installed in accordance with the manufacturers
specifications- must have manufactures letter of
warranty with the address on the letter for final inspection
Hersh Raof
AW 1 8e1aulreme0
0 Fall Metal roof shingles shall not be installed on slope less
N/A ra Pass
3:12
M&taj -va y ftsbing sins''t be isle sama matefti as roar
N/A a Pass
a Fait
Q fail Metal valley flashing shall extend a min of 8" from the
N/A PON
centerline with a min, of 3/4 " high splash diuerter
rib built-in at the flow line with sections overlapping a
a min. of 4"
ilia ago
820miromfm
0 Fall Clay and {'AnCr@ti3 telt: shall have a Cion. 2-1/2:12 slope
i N/A o Pass
Mopes 4:12 and under require double underlayrnent
The City of Wheat Ridge
Inspection Check List notes
Final Roof
Notes
Company Name:.%
inspector signature:
Date of inspection:
Mg=
rye
N=
NME=
mmfl�
191AItttU
1 11 1
CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office" (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type 7,5'W . IAAAAz'i5-
Job Address !� v o &a Y
Permit Number //07,2`x°
o?No one av
City of Wheat Ridge
1�
Faxed Mech. Permit PERMIT - 110929
PERMIT NO: 110929 ISSUED: 08/08/2011
JOB ADDRESS: 6840 W 48TH AVE EXPIRES: 08/07/2012
DESCRIPTION: Install 75K BTU upflow furnacein basement
* ** CONTACTS * **
Owner 303/274 -5479 Warren Johnson
GC 720/236 -1330 Steve Byers 10 -0232 Energy Logic Solutions Inc.
** PARCEL INFO **
ZONE CODE: UA USE: UA
SUBDIVISION: 0009 BLOCK /LOT##: 0/
** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 1,900.00
FEES
Permit Fee 40.00
Total Valuation .00
Use Tax 34.20
** TOTAL ** 74.20
Conditions:
Work shall comply with 2006 IRC & 2005 NEC. Per IRC Sec. R313, smoke detectors
are required to be installed in every sleeping room, in hallways outside of
sleeping rooms, and on every level of the structure. Carbon Monoxide detectors
are required to be installed within fifteen(15) feet outside the entrance to
each sleeping room. Subject to field inspection.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and
specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the
legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform
the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all
entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in
this document and /or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and
specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances,
regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must ...
be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted
at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to
the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired
permits is at the sole discretion of the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior
and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy
of all required inspections and shall not proceed or conceal work without written approval of such work from the
Building and Inspection Services Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of
any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject
to field 'na ion.
Sign
atu ief Building Offical Date
INS CTION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855
REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
* I I vnq
Drywall
FINALS
Electrical
AaLaie1 1U:LVKVV0CitY
BPSP Install 75K BTU upfl
110929
Permit Fee
Use Tax
Mechanical PAYlME14T RECEIVED
NC 9164
Roof Auth Code:
06id23
Building Final - - TOTAL
Fire Department
NI
AKU
74.20
40.00
34.20
ANOUNT
74.20
74.20
R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLIC WORKS SHOULD
Parking & Landscaping BE CALLED AT LEAST ONE WEEK. PRIOR TO FINAL INSPECTIONS..,.
* `NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A
CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DiviSION'D,OES NOT CONSTITUTE AUTHORIZA7ION
OFA CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUP
OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF 'OCCUPANCY IS ISSUED
PROTECT THIS CARD FROM THE WEATHER
= Inspections will not be made unless this card is poste on the building site
all by 3:00 PM to receive inspection the following business day.
toR 1) 1 Ua I",/9 A a
INSPECTION RECORD Occupancy /Tyne
'O - INSPECTION LINE: (303) 234 -5933
INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS .JOB
FOUNDATION INSPECTION$
DATE
INSPECTOR
INITIALS
COMMENTS:
Footings /Caissons
Stemwall / (CEG) Concrete
Encased Ground
-
-
Reinforcing or Monolithic
PRIORTOPRO
CITY OF WHEAT RIDGE
08.Ii5 /11 3:18 PH cdba
Carlos A. Espinoza
Weatherproof/ French Drain
Rough Plumbing
Sewer Service Lines
Gas Piping ,
Water Service Lines
Rough. Mechanical
POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED
CONCRETE SLAB FLOOR
Electrical (Underground)
Insulation
Plumbing (Underground)
Screw
Heating (Underground)
ROUGHS
Sheathing
Lath / Wall tie
Mid -Roof -
Electrical Service
PRIORTOPRO
CITY OF WHEAT RIDGE
08.Ii5 /11 3:18 PH cdba
Carlos A. Espinoza
Roug Electr '
Rough Plumbing
Gas Piping ,
Rough. Mechanical
_ ABOVE INSPECTIONS TO RESIGNED
Framing
Insulation
Screw
08/15/2011 MON 15:15 FAX 7202361329 0001 /001
City of
1� Date:.
SS
'` C�f 1tCibtUN1`Pl'i)(:V fa_CIPAA I:N "f
Plan #
Building & Inspection Services Division Permit # G7
7500 W. 29" Ave., Wheat Ridge, CO 80033 / 2 �•
Office: 303- 235 -2855 *Fax: 303 -237 -8929
Inspection Line: 303 - 234 -5933
Building Permit Application
Property Address: YBT4
Property Owner (please print): Z�U jZ�y� :7 - 2 04 Phone:
Mailing Address: (if different than property address)
Address:
City, State, Zip
Contractor:
Contractors
License #•
2
Phone:
w,uugl.::tN 15 "
Electrical: Plumbing: Mechanical:
City License # City License # City License #
D'cscriptiori of tncbrk
/lSii/tLj ivs 7v1L l�tbw �vt1hF3C1� /h-t Contract Value :.
- - Review Fee (due at time of submittal):
Squares BTU's Gallons _ Amps Sq Ft.
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances,
rules or regulations of the City Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and
allegations made are accurate; that I have read and agree to abide by 0 conditions printed on this application and that :I ssswne full
responsibility compliance with applicable City of Wheat Ridge codes and ordinances for work under any. peanit'issued based on
this. application;.that I am. the legal owner or have been authorized by the legal owner of the. property to perform the described work
- acid am also authorized by the legal owner of any entity included on this application to list that entity on this application.
CIRCLE ONE.• , , (OWNER) (CONTRACTOR) o (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR):
PRINT NAME: �iA7I.Lb S ' T� SICNATURB /_�i� '� DATE:
verai <ilnpw7 t7ap}�roved,tllfapnii)tp1+YS t�}tis�pprov�d � Ile rau7elWJegttire{t,'.� Bldg Valuation: $_
♦ t CITY OF WHEAT RIDGE
f Building Inspection Division
r (303) 234 -5933 Inspection line
(303) 235 -2855 Office • (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type: . iurL A1cw
Job Address: c 0 cy Pf8e7/ �
Permit Number: 101-g
El No one available for inspection: Time l_ (CM
Re- Inspection required: Yes o`
When corrections have been made, call for re inspection at 303 -234 -5933
Date: - Inspector
DO NOT REMOVE THIS NOTICE
I
I 1� � 4 ♦ V11fX7 of Whn-at P;Atsn
PERMIT NO: '4101578 ISSUED: 06/22/2010
JOB ADDRESS:: 6840 W.48TH AVE ;EXPIRES: 12/19/2010
DESCRIPTION:!.Reroof 15 sqs with 30 yr Timberline shingles
* ** CONTACTS * **
owner 303/887-9221 Warren Johnson
sub 363/763-9114 Lorin Hanson 01-9938 Interstate Roofing Incorporate
** PARCEL INFO **
ZONE CODE: UA USE: UA
SUBDIVISION:' 0009 sBLOCK /LOT #: 0/
z.
'^ ** FEE SUMMARY ** ESTIMATED PROJECT :VALUATION: 3,150.00
e FEES
Permit Fee 126.50 5
�.; Total Valuation .00
Use Tax :56.70 ,�-
"" ** TOTAL ** :183.20
9`
Conditions:
�? 6 nails per shingle is required. Ice dam membrane is required from eave edge to
2' inside exterior walls. Board sheathing with any gap greater than 1/211 '
W tATY OT VVIMUL RIUIq. C L�Urtr+111Y N.vw.vr,
7500 W. 29 Ave., Wheat Ridge, CO 80033
Office: 303 - 235 -2855' Fax: 303- 235 -2857
Inspection Line: 303 - 2345933
166 E Ci Building Permit Application
✓aLV.
Plan #:
Permit #.
Property Address: f
Property Owner (please print)' ar re v oti 50 Phone: 3 ° 3 ``
Mailing Address: (if different than property address)
Address: 6%F)c(0 w � � Ar,e
City, State, Zip' W`1,.e j (Li c° r o &06> 3
Contractor'
Contractor License #: Phone: 3 0 3 - 763 _ `C(( r/
Sub Contractors:
Electrical City License # Plumbing City License #: Mech iral City License
a #:
Company: Company y:
Exp. Date: Exp. Date: Exp. Date:
Approval: Approval: Approval:
lZ —
'C 1Z_Co I i
- Construction Value: s
Use of space (description), (as calculated ner the Bufidin vaNation Datasheal)
Description of Work' 6 > 4 4 e -c (CL C e �1
C rtr" Plan Review (due of time of submittal): $
Sq. Ft.IL. added: Squares G BTU's Gallons Amps
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
1 hereby certify that the setback distances proposed by this permit application are accurate, and d lail a mets shown,
or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that measurements
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work
under this permit. Plans subject to field inspection.
CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESEN ATIVE of (OW 8R) ( CONTRATOR)
PRINTNAME: I.or: K 'p- I')'"�se� -- SIGNATURE - - �' r El G ZL`2 -1P
IJEPA6RTM.ENT MWONLY
ZONINGZOMMENTS:
Zqning; .. .. ...
Reviewer.
PUBLIC WORKS COMMENTS:
Reviewer:
OCCUPANCY:_
BUILDING L EPARTILILNT COMMENTS: ..
Reviewer: .. .
FIRE DEPARTMENT:: G approved w/. comments . 0 disapproved G no review required — Bldg Valuation:
DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 14313
BUILDING INSPECTION LINE - 303-234-5933 Date : 8/9/02
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Property Owner.
Property Address : 6840 W 48TH AVE Phone : 420-6446
Contractor License No. : 17152
Company : Precise Plumbing Phone : 534 0881
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certiry that the setback distances proposed by this pertnit application are accurate, and
do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restridions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
appliwtion, and that I assume full responsibility for compliance with the Wheat RidgeBuilding
Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit.
Construction Value :
$493.00
Permit Fee :
$23.50
Plan Review Fee :
$0.00
Use Tax :
$0.00
Total:
$23.50
(OWNER)(CONTR4CTOR) SIGNED DATE US0 :
Description : REPLACE WATER HEATER, READY FOR INSPECTION U~J
BUILDING DEPARTMENT USE ONLY
SIC : Sq. Ft. :
Approval :
Zoning :
Approval :
WN
Approval:
Occupancy : Walls : Roof : Stories : Residential Units :
Electrical License No : Plumbing License No :17152 Mechanical License No :
Company : Company : Precise Plumbing Company :
Expiration Date : 9/13/02
Expiration Date : Approval : OK/KS Expiration Date :
Approval : Approval :
(1) This permit was issued in accordance with the provisions set forth in yopur application and is subjed to the laws o/ the State of Coloratlo and ro the Zoning
Regulations and Builtling Code of Wheat ftidge, Coloratlo or any other applicable oMinances otthe City.
(2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue tlate or (B) the building auNOrizetl is suspended or
abandoned tor a period of 120 days.
(3) If this permit expires, a new permit may be acquired for a fee of one-half ifie amount normally required, provided no changes have been or will be made in ihe
original plans and speciications and any suspension or abandonment has not excee0etl one (1) year. If changes are matle or if suspension or abandonment
exceetls one (1) year, (ull fees shall be paitl for a new permit.
(4) No work of any manner shall be done ihat will change the natural flow otwater causing a drainage problem.
(5) Contrector shall notify the Building Inspector hventy-tour (24) hours in atlvance for all inspeclions and shall receive written approval on inspection card before
proceediing with successive phases otthejob.
(6) Th :sa~ance of a pertnit or the approval of tlrawin95 and specifcations shall not be construed ro be a permit for, nor an approval of, any violation of the
is ns o the e ding codes or any other ordinance, law, rule or regulation.
Chief Buildi Inspector~
DEPARTMENT OF PLANNING AND OEVELOPMENT Building Permit Number :
BUiLDING INSPECTION ONISION - 235-2855 .
CITY OF WHEAT RIDGE Date :
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Property Owner :
• Property Address :
Contractor License No. :
6 sryo le, a^ 1-~~
7/ f-':2-
companY : P- P c is e/,"/~m <; ^ y.:~ c-
~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING ANO AGREEMENT
I heroby certAy that the aetbadc tlistances proppyetl q this permrt aPOitcation ars axunats.
arM tlo no[ viobte aoDbcabb oramands. rubs or repuuuons ot Ns City of Wl+eat Ridye w
(OWNER)(CONTRACTOR) SIGNEDA ' pATk Phone : 4/2 0- c yy 6
covanams. easemenls w restnGqns af 1ewrtl: that aY mesfummsMS sAOwn. ana aCSpaWns
;maee aro aeeunce: tnat I Aavo nsaa ane aprss w abds Dy au ooneiGOns pnntetl on this
appYCaGOn. ana mn 1 assume futl roaponseiYly for.wrt~ppanq y~qh Me Whsn Ritlge BuYtl'vg
CoEe (U.B.C.) ana afl otl+x appiiabN Whsat F~iOp omnanoes. !or work undx Mis portnR.
' 3ej)
Phone : rsr/
conswction vaiue : y ?-3 -
Pertnit Fee : .2 ~i S'e
U5BT2X;.Q--ri'S PGO.
TOtal : 2 a S d
Descnption : r~V/ce ilyo. ~ rtac,~ K'd1-
BUILDING DEPARTMENT USE ONLY
Approval :
Zoning :
Approval :
PObI[ hdt~itmwn3s:!
Approval :
Occupancy : Walls
Roof : Stories : Residentlal Units :
Electncal License No : Plumbmg License No : MeChanical License No :
Company :
Company:
Company :
6cpiraHon Date : Expiration Date : Expiration Date :
Approvai: Approval: Approval:
~ : P,fVfwRTqqu(red=- PIEs Rdquirod."'
( t) . rnR permrt was uwea n acmroana wm eia pwuiau sel brm n yoour aopinaon ana u suqw m tIN iaws W IM Suq of Cdoqro Uq m tlr Imnp
Repuuums ana Bu~laug Coae M Wnaa~ Wdqe. Co;anao a airy mnar aopupdW oroinands W me G1y.
(2) TT~s Ws~au sspn A IAI Oia wa~c awqnsea a rot mmMnoea wnwn sixty (60) OaYS hom ww Cap 01 (8) tM OuYCVq autfaiasc s wsOrkM or
aoanaoneo ror a oa+oo a 120 aaya .
(a) u w. wrri,n.:am... ,l,.Y. o«n.~ m+r w.m+na ror, r« a on.r.n m• amawn nuffn+w tiaw.a. awnw nm e~ «WWI a m.a n me
a+puW aana ana ipaakueons ana any suqomsen a awmonrrwa nu not e■nww one (1) y*r. d wiqw ~n mw~ a n wspwaon a awrwomwn
aoeeas oM 11) reo. hM hef uW Oe ww ror a now eanm.
(4) No WOfk of alry TiMlI 3Mtl Df Oplf CYI WW M]I" py lyryM Ilpy pf wilM fJU3Mq i OfaIMqo pm0WT.
(5) Conuanor snan rauM u+e Bunan9 inaewor nvvrry-iour Rp nww u+ awanee ror an msWaons ana tnae racana wnaan aoprovai on nsoocoe ura
OroCSeOnnq wiN suw3srva OM3G7 W Ifle p0.
(6) Tne uswnce of a oermrt a me aOWwai W arawmqs ana soMRrauons snall not oe mnswaa W DO a permt for. ny an oP0rova1 of. arry voa0w WrA Orwunru
of Ne Du.l0.n9 ~l5 OI iny ONlf OfO~Iti~IR, yw. N:t OI fl9WV011.
Chief Bwlding Inspecror For Mayor
THIS ?ERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR
CALL: 2345933 24 HOURS PRIOR TO INSPECTION
COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 16161
BUILDING INSPECTION LINE -(303-254-5933) Date : 9/3/2003
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80033 - (303-235-2855)
Property Owner: 6840 48TH AVENUE
Property Address : CHRIS CRISMAN
Contractor License No. : 19569
Phone : 420-6446
Company : Candlelight Electric Phone : 935 9841
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and
do not violate applicable ordinances, rules or regulations of the City of W heat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on lhis
application, and lhat I assume full res nsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable inances, for work under this pertnit.
(OWNER)(CONTRACTOR)SIGNED DAT % v
Construction Value :
$4,371.00
Permit Fee :
$144.70
Plan Review Fee :
$0.00
Use Tax :
$52.45
Total:
$19715
Use:
Description : 200 AMP UNDERGROUD SERVICE CHANGE TO 50 AMP 240 VOLT
m
BUILDING DEPARTMENT USE ONLY
ZonJr}g`Comrrients:( SIC : Sq. Ft. :
Approval :
Zoning :
Sul Idi~lg' Com ments: ,
Approval :
putijl`c Illtorks;Gamment`"sr
Approval :
Occupancy : W alls : Roof : Stories : Residential Units :
Electrical License No :
Company:
Expiration Date :
Approval:
Plumbing License No :
Company :
Expiration Date :
Approval:
Mechanical License No :
Company:
Expiration Date :
Approval:
(1) This pertnit was issued in accordance with the provisions set forth in yopur appiication and is subjecl to the laws of the State of Colorado and to the Zoning
Regulations antl Building Cotle of W heat Ridge, Colorado or any other appliwble ordinances of the City.
(2) This permil shall expire if (A) the work authorized is not commenced wilhin sixty (80) days from issue date or (B) the building aulhonzetl is suspended or
abandoned for a period of 120 days.
(3) If this permit expires, a new permit may be acquired for a fee of one-half the amounl normally required, provided no changes have been or will be made in the
onginal plans and specifcations and any suspension or abandonment has not ezceeded one (1) year. If changes are made or it suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new pertnit.
(4) No work of any manner shall be done that will change the naNral Flow of water causing a dreina9e problem.
(5) Conirector shall notify the Building Inspector twenty-four (24) hours in advance for all inspedions and shall receive wririen approval on inspection card before
proceediing with successive phases of the job.
(6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the
provisions of the building codes othet oe, law, rule or regulalion.
Chief Building Inspe o= I4
Please sigrYTerms and Conditions on reverse side of page.
of WHEqr DEPARTMENTOFPLANNINGANDDEVELOPMENT Building Perm it Num ber:
ti o BUILDING INSPECTION LINE - 303-234-5933 Date:
u m CTTY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
C~C OR P00 5~F
APPUGSd ON
. Property Owner: e`14S
ProperryAddress: ~,~qp N/ 484a AW: Phone:303'S'ZV -(-,1qf-
ContractorLicenseNo.:.ANatrT
ComPanY: Cn~n~f ~Q ~'~L~ c..~ C~/ _ Ph9ne ` Y3 S • S Y~IS
OWNER/CONTRACI'OR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distanccs proposed by this permit applicatio¢ aze accurate,
and do no2 violah applicable ordinaaces, mIa or rogulafions of the Ciry of Wheat Ridge or
this permit ConstructionValue:$ 1i3"7/
wvenanu, easeme¢is orrestrictlons ofrecord; that alI measuroments shown, and allegations
made are accurate; that I have read and agroe. to abide by all condilions printed on this
application and that I azsume fiill responsibility for compliance with the Wheat Ridge
Building Code (U.B.C) and ell other applicable Wheat Ridge Otdinances, for work under
Permit Fee:$
Plan Review Fee:$
USC 13X:$
Total:$
Description: Zfc) :givllQ 1,(/G- Se ew, C ~ C GIR~9 e-- 0 .4~aP Z--L(o votf- /~')enc.-f,'/'
4,, SA"Ye '5w6 P.s„ci-, 14aU, n, Gt' h fs f ov04-f9 /t, G'y-,.n9e.
BUILDING DEPARTMENT USE ONLY
SIC: Sq.Ft.:
ZONING COMMlNTS: .
Approval:
Zoning:
BUILDING COMMENTS:
Approval:
PUBLIC WORKS COMMENTS:
Approval:
Occupancy: V✓alls: RooE Stories: Residential Units:
Electrical License No: Plumbing License No: Mechanical License No:
Company: Company: Company:
Expiration Date: Expirarion Date: Expirarion Date:
Approval: Approval: Approval:
(1) Ifiis pumit was issued in aceordance with the provisions set foeth in your appficarion and is subject to the Iaws of the State of Colorado and to the Zoning
Regulaaons nnd Building Codes of PJheae Ridgq Colorado or any other appliwble ordivances of Ne City. (2) iltis pamit shall ezp¢e if (A) the work authoriud is not commenced within vrzty (60) days from issue date or (B) the buJding auNOrized is suspended or
abmdaned fm aperiod oF 120 days.
(3) if tlila pamit expues, a new pwmit may be acqitired for a fee of o¢e-Ualf fhe amount nomally requiro4 VTOVided no changes have bem or will be made in
the original plans andspecificafions md any suspension or abandonment6u not exceeded one (1) year. ifGianges have been orifsuspensinn nr ahanAnnmenr
exweds one (1) yeaz, fWl fees shall be paid for a new pertnit.
(4) No wodc of a¢y menner shall be done that will chauge the naNal flow of water causing a drainage problem.
(5) Contac[orshallnoRfytheBuildingInsp<MOrlwmry-fow(24)Iioursiuedvanceforallinspectionsandshallmceivewrittenapprova(oninspeceonexrdbeforc
pzaceedi¢g with suuessive pliazes of Nejob. (6) ltte issuence of a pecmit or the approval of deawings and speci5cafions shall not be constued ro be a pemit for, nor av apprwe7 of, any viafanon of the
prorisions of the buldi¢g codw or my other ordinance, Iaw, rule or cegulavon.
Chief Building Inspector
F-:
a =
w
0 0 (1)
~ f!!
Z > .V
W 0 O
a yww)) Z
d~
~ C~ N
J • _
W ~ M
> 4) N
WyM~
~ C M V
~ o v L
'r L
? d ~
~ CL U
o~
U
~
~
~
O
~
N
N
Gf
v
Q
Q
O
~
~
0
v
m
a
N
~
.
~
~
w
~a
0
a~
v
m
E
~
a~
a~
~
~
>
co
~
~
c
0
:r ri
N Omf
~ N
O '
U~
M
C N
N ~
L M
> O
> M
b
~
t
6~~.
DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 95-1261
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE Date :6/22/95
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Property Owner : BUSH LEE ROY A
Property Address: 6840 48TH AV
Phone: 421-7722
Contractor License No. : 17546
Company : Paul Davis Systems of Jeff. Co., Inc.
Phone : 422 3232
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Construction Value : $2,000.00
I hereby certiTy that the setback distances proposed by this permit application are accurate,
P@fmlt F@e : $45.00
and do not violate applicable ordinances, rules or regulalions of the City of Wheat Rid9e or
covenants, easements or restrictions of record; that all measurements shown, and allegations
Plan Review Fee : $0.00
made are accurate; that I have reatl and ayree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit.
USB TaX : $30.00
)1_1d-1 e L7- AbZ t'~' DATE
TOfal : $75.00
(OWNER)(CONTRACTOR) SIGNED
Description : REROOF
Electrical License No : Plumbing License No : Mechanical License No :
Company : Company : Company :
Expiration Date : Expiration Date : Expiration Date :
Approval: Approval: Approval:
(1) This permif was issued in accordance with the provisions set forlh in yopur application and is sub1'ecl to ihe laws of the State of Colorado and to the Zoning
Regulations and Building Code o( VJheat Ridge, Colorado or any other apDhcable oMinances of the City.
(2) 1Tis permit shall expire if (A) the work authorized is not commenced within sixry (60) tlays from issue date or (B) ihe builtling authorized is suspended or
abantloned for a periotl of 120 Oays.
(3) If ihis permit expires, a new permit may be acquired for a tee oF one-half the amount normally required, provided no chan9es have been or will be made in the
original plans and specifcations and any suspension or abandonment has not exceetled one (1) year. If changes are made or if suspension or aDandonment
exceeds one (1) year, Full fees shall be paitl for a new permi[
(4) No work of any manner shall be done that will change the naNral Bow of water causing a Arainage problem.
(5) Coniractor shall noGfy the Builtling Inspedor tweny-four (24) hours in advance for all inspechons and shall receive written approval on inspection car0 before
proceediing with successive phases of ihe 7ob.
(s) The issuance of a permit or the approv of drawings and speciecations shall not be construed to be a permit for, nor an approval of, any violation of the provisions
of t~i bui ing wtletser any oty1r ordi nce, law, rule or regulation.
1~
dinglnspectar
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION
DEPARTMENT OF COMMUNITY DEVELOPMENT
7500 WEST29th AvENUE BUII DING INSPECTION DIVISION PERMIT N0.
234-5923 P.O. BOX638 CITY OF WHEAT RIDGE, COLO.
THiS PERMIT VALID ONI.v WHEN SiGNED BY ThE rNfEF BWLDiNG MSPECTOR AND RELEIPTEDBELOW.
APP ICA 0~~JJ ~~OR MISCELLANcOUS PERMIT y~
JOB ADDFiESS ~ ' ~ OWNER L'E-t
CONTRACTOR ADDRESS 0
CITY Kf L,Itah
PHONE yA`)'-
LICENSE NO.
Z
1. TVPE GrounE❑ Wall❑
2. MATERIAL
SIGN$ 3. ILLUMINATION Yas❑ No❑ Type
4 SET BACK FROM PROPERTY LINE N_ 5_
(Soeci}v whicA ia front) ❑ ❑
1. TYPE SolidO Mora Thon BO% ODenO
ADDRESS '-n ~ v w - ~i s _/-r v'-
PHONE 1421- 772 L' ZIPCODE
CONTRACT PRIC $ Z oc/
DATE ~'ZlAl 5
Pwiectinp❑
Othsr SaDFoce
Totol Squan FeN
ElW
Pvmit No
_ W
.
.
Zons_ ApprovM,ZOne Inspeefor
Len Thon 80%
FENCES I?, MATERIAL HeipM
3. SET BACK FROM PROPER7Y LINE N_ I-I S_ E_ W Zme_ ApprwW,2om Inspstfa
(SOecifv which ie tronf) L.I ❑ ❑ ❑ MscDDrowd
I
OTHER z Ye - IrOC` 3
13,
DRAW SKETCH pR SHOW BELOW, TNE FENCE, SIGN, OR OTHER STRUCTURE, GIVIhG DISTANCES FROM PROPERTY LINES.
(SETBACKS OR PROJECTqNS INCI.UDED)
L- l V f( t`n1Y=
G' ZIP CODE ~
~
SPECIFV NORTH
STREET N4ME
SNOW DISTANCES FROM THE M41N BUILDING TQADJOINING HOUSES, STREETS, AND PRpPERiY LINES;ON IRREfiULAR LATS, SHdW LEAST
DISTANCE TO PROPERTY lINES, NOT MA%IMUM OR qVERAGE DISTANCE.
APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT
THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION.
PERMIT WILL EXPIRE 180 DAYS 1-Ii0M THF DATE OF ISSUANCE If WORK IS NOT STARTED WITHIN THAT TIME.
ELECTRICAL PERMIT
STATE LICENSE N0.
ALUMINUM WIRE UNDERSIZE 8 ILLEGAL
PLUMBWG PERMIT
STATE LICENSE N0.
FLOOR BSM IST 2N0 3RD 4TH
MECHANICAL PERMIT
N0. Fl1EUCirtNOrN GW 01I E Sdm
Np.
WATEH CIASET
FORCED AIR - 8TU
TEMPORARY METER
WASH BOWL
HOT WATER - BTU
NEW SERVICE - AMPS
BATH TUB
STEAM - BTU
CHANGE SERVICE-AMPS
SHOWER
AIR CONDITIONING-BTU
LIGHTING
SINK
OTMER
HEATING
POWER SU9-CIFCUITS
GARBAGE DISP
WATER HE4TER
REFRIGERATqN SYSTEM
Re}ri aront GrWp
UTILITY(RANGE,DISPOSER,E7C)
AUTO. WASHER
Poundt CAOr e
FIXTURES
DISH WASHER
AUTOMATIC SPftINKLER SYSTEM
WIRING MOTORS 9 CONTROLS
FI.OOR DRAIN
ELEVATOR
SIGNS
URINGL
TRANSFORMERS 6 RECTFIERS
SEWERS
ADDITION TO OLD WORK
OTHER
MOTORS OVER I HP
TOTAL FIxTURES
I Aareby ocknowladqe ihot ihis op0lica-
tion iE correct and underatand thot I
connof stort thif projett until this aDDli'
CotiOn if oDGroved. I sholl comDly with
1M lows oi Ihe Stafe oi Colorado and to
fha ZoninQ ReQulotions ond Buildina
Code ofthe City ol Wheai Ridpe. Any
violatio pf the obove terms will cause
immedotb revocotion of tnis permit
4oo~lcunu sla~a~w. / .
\
PERMIT FEE
I USE TAX I~3 C) cw I
I TOTAL FEE I$ I
APPROVED
DISAPPROVED
CHIEF BUILDING INSPECTOR,City of Wheat Ridqe
Date
UNLE55 RECEIPTED
CALL 2345933
24 HOURS IN ADVANCE
FOR INSPECTIONS